2" LED Adjustable
DATE:TYPE:
A2LED
FIRM NAME:
PROJECT:
High Output
APPLICATIONS:
LED LIGHT ENGINE:
J-TUBE ASSEMBLY:
LED DRIVER:
Architektuˉr A2LED Series is a 2” specification
grade LED Adjustable Luminaire that
combines superior brightness control with
energy savings and low maintenance costs.
Suitable for a variety of commercial, retail,
and institutional applications with ambient
temperatures up to 35ºC (9L) 25ºC (12L)
during operation with free airflow around
the fixture.
High output Xicato XSM LED Module
(IP66 rated). Color consistency held to
less than 2 SDCM's for fixture to fixture
and over-time color consistency. Secured
to an extruded aluminum heat sink for
excellent thermal management providing
optimal life and lumen maintenance
(minimum 50,000 hours at 70% lumen
maintenance).
Utilizing Prescolite's revolutionary J-Tube
design and optimal thermal management, the
A2LED eliminates the need for a traditional
downlight housing. The J-Tube assembly
combines the traditional J-Box and driver
electronics into a compact form that can
be accessed from below the ceiling plane.
These features allow the A2LED to ship as a
single unit which can be completely wired
and installed from below the ceiling plane.
It can also be easily removed from below
the ceiling if servicing or an upgrade to new
technology is ever required.
VOLTAGE
❑BLANK
120V
❑277
277V
2-1/4"
3-1/8"
5-1/4"
WARRANTY:
A
EXAMPLE: A2LED277V-2A9LED 30K8FL35WCWT
5-1/4"
❑2A9LED
2" Open
Reflector/
Light Engine
Assembly with
Xicato module
❑9L1
900
Delivered
Lumens
❑12L1
1200
Delivered
Lumens
❑27K
2700
Kelvin
❑30K
3000
Kelvin
❑35K
3500
Kelvin
❑40K
4000
Kelvin
LOWER
REFLECTOR
FINISH
30°
CRI
❑8
Nominal
80+ CRI
❑9
Nominal
95 CRI
BEAM
ANGLE
❑Blank
Specular
❑SS
Semi-Specular
❑MFC7
American
Matte™
❑FL35
Spun Aluminum
relfector with
a 35º flood
distribution
1
See page 2 for specific lumen per module and raw lumens
2
See Central Inverter compatibility note and web links on page 3.
3
See page 4 for line art
4
Either CT, WT, or BT must be specified with a painted cone
5
With Alzak finishes, flange will match the trim finish. WT or BT
may be specified as needed.
6
Upper reflector is always specular clear alzak
7
Not available with BC or WC
OPTIONS
STANDARD
LOWER
HDM
LDM
REFLECTOR
DM01
COLORS
J-TUBE
DIM "A"
7-3/4"
16-1/4"
6"
10"
❑Blank
Clear Alzak
❑CG
Champagne
Gold Alzak
❑BL
Black Alzak
❑WE
Wheat Alzak
❑LW
Light Wheat
Alzak
❑PW
Pewter Alzak
❑BC4
Black Painted
Cone
❑WC4
White Painted
Cone
DIM "B"
9-1/2"
LOWER
18"
7-3/4"
REFLECTOR
11-3/4"
OPTIONS
_
❑Blank4,5
Anodized Trim
❑CT4
Clear Trim
❑WT4
White Trim
❑BT4
Black Trim
•
Tech Support: (888) 777-4832
ACCESSORIES
❑LiteGear2
Inverter, single phase central
lighting, 125VA-250VA
❑ LPS Series2
LitePower micro-inverter,
20VA-55VA
❑D2FRM3
Optional Mounting frame for
the A2LED fixture.
LOWER REFLECTOR
ANGLE CUT
❑Blank
Standard Slot
to accomodate
30º aiming
❑AC15
Slot to
accomodate
15º aiming
❑FC
Full cut for
vertical aiming
only
In a continuing effort to offer the best product possible we reserve the right to change, without
notice, specifications or materials that in our opinion will not alter the function of the product.
Web: www.prescolite.com
DIM "B"
9-1/2"
18"
7-3/4"
11-3/4"
LINE VOLTAGE
CONDUIT
OPENING
B
3-1/8"
LED
COLOR
DIM "A"
7-3/4"
16-1/4"
6"
10"
KNOCK-OUT
0-10V DIMMING
MODELS ONLY
2-1/2"
2-7/8"
CEILING
5 Year Warranty. Go CUTOUT*
to
www.
prescolite.com for full details.
OUTPUT
J-TUBE
*Note: The accuracy of the 2-7/8" ceiling
cutout is critical to the proper fit of the D2LED.
For installation hints see page (?) or download
the instruction sheet from www.prescolite.com
6-1/2"
LIGHT
ENGINE
A Division of Hubbell Lighting, Inc.
OPTIONS
STANDARD
HDM
LDM
DM01
30°
CSA C/US certified to UL1598.
Suitable for damp locations. Non–IC
2-3/4"
rated and 2IN/2OUT through branch
wiring. For connection to flexible
conduit only.
Order housing, reflector, and accessories separately
❑BLANK
Standard
0-10V dimming
❑HDM
Lutron Hi-Lume
A-Series 3-wire
or EcoSystem
dimming to 1%
❑LDM
Leading Edge
dimming to
10% (12L &
120V only)
❑DM01
ELDO LED
0-10V dimming
to less than 1%.
B
2-1/4"
_
2-1/2"
2-7/8"
CEILING
CUTOUT*
CERTIFICATIONS:
CATALOG NUMBER:
❑A2LED
2" J-Tube
Assembly
with 0-10V
Dimming
standard.
6-1/2"
Comes standard with 0-10V standard
dimming capability. Flicker-free dimming
to 10%. For sizing control systems, the
0-10V control circuit will draw up to 1
mA. Also available with 0-10V to below
1%, Lutron Ecosystem to 1%, and Leading
Edge to 10%.
A smooth 35º optical pattern is adjustable up
to 30º from vertical. The vertical aiming must
be adjusted and locked before installation.
Prescolite's spring loaded retention allows
360º horizontal aiming during installation.
OPTIONS
A
DIMMING:
High purity spun aluminum self-flanged
reflector with iridescence suppressed Alzak
anodized finish. The lower reflector is also
available with Prescolite's American Matte
finish (MFC).
*Note: The accuracy of the 2-7/8" ceiling
cutout is critical to the proper fit of the D2LED.
For installation hints see page (?) or download
the instruction sheet from www.prescolite.com
2-3/4"
Energy efficient electronic constant
current driver with 50,000 hour minimum
anticipated life. Meets UL Class 2, FCC
47CFR Part 15, Class B compliant,
inherent short-circuit protection, self
limited, overload protected.
REFLECTOR & OPTICS:
J-TUBE
ASSEMBLY
Ceiling Cutout: 27/8"
Ceiling Thickness 1/2"-1 1/4"
For conversion to millimeters,
multiply inches by 25.4
Not to Scale
ARCH-LED-012
PHOTOMETRIC DATA
Architektū
¯r - 2" A2LED Downlight
ELECTRICAL DATA
A2LED9L8
A2LED9L9
A2LED12L8
Input Voltage
120/277V
120/277V
120/277V
Input Frequency
50/60 Hz
50/60 Hz
50/60 Hz
Input Current
0.14/0.062
0.170/.076
0.20/0.087
Input Power 17 Watts
21 Watts
24 Watts
Constant Current Output 760mA
760mA
700mA
Power Factor
≥0.90
≥0.90
≥0.90
EMI Filtering
FCC 47CFR
FCC 47CFR
FCC 47CFR
Part 15, Class B
Part 15, Class B
Part 15, Class B
Fixture Operating
Temperature
-30ºC to 35ºC
-30ºC to 35ºC
-30ºC to 25ºC
Dimming
0-10V to 10%
0-10V to 10%
0-10V to 10%
Over-voltage, over-current,
(short-circuit protected, and over-temperature protection with auto recovery)
7
95 CRI
12L
1.0
.66
9L
0.71
0.57
NVLAP LAB CODE: 201003-0
om
-30ºC to 25ºC
0-10V to 10%
Xicato Module Chart
Lumen Multiplier For CRI
Options
80+ CRI®
A2LED12L9
120/277V
50/60 Hz
0.18/0.08
22 Watts
700mA
≥0.90
FCC 47CFR
Part 15, Class B
12L
*For exact lumen outputs, please visit
www.prescolite.com to find IES reports
9L
PAGE: 2 OF 6
DATE SAMPLE TESTED: 07/15/13
35 HIGH OUTPUT
3000K HIGH OUTPUT]
80+ CRI
95 CRI
2000
1300
1420
930
1300
1000
1000
800
Drive
Current
Xicato XSM Module
700 mA
Module Delivered Lumens
Xicato XSM Module
760 mA
Module Delivered Lumens
Drivers
ZONE
CANDELA DISTRIBUTION
90˚
90º
75˚
75º
450
450
60˚
60º
900
900
45˚
45º
9
R
1350
1350
0º0˚
15˚
15º
DEG
0
5
15
25
35
45
55
65
75
85
90
LUMENS
%LUMINAIRE
0-30
870
79.2
0-40
1052
95.9
0-60
1097
99.9
0-90
1098
100.0
0-180
1098
100.0
CANDELA LUMENS
1255
1250
1220
934
262
48
3
1
0
0
0
119
341
409
183
42
3
1
0
0
30˚
30º
Checked
LUMINANCE DATA IN CANDELA/
SQ. METER
Angle in Vertical
Average - 0º
45°
26453
55°
2038
ZONAL LUMEN SUMMARY
A2LED 2A9LED12L30K8FL35
LED Light Engine: 3000K, 80 CRI
System Wattage: 22.7
Fixture delivered lumens: 1098
Spacing Criteria: 0.9
922
75°
85°
0
0
% Effective Ceiling Cavity Reflectance
80%
70%
50%
30%
10%
20% Effective Floor Cavity Reflectance
% Wall Reflectance
10
50
30
1
2
114 111 109 107 111 109 107 105 105 103 102 101 100 99
109 104 100 97 106 102 99 96 99 96 94 96 94 92
98
93
97
91
96
90
3
103 97
89
86
84
4
70 50 30 10 70
99
91
93
86
50
89 101 96
82
97
90
30
92
85
10 50 30 10 50
88
82
93
88
90
84
87
81
91
86
30
88
83
85
80
84
81
10
79
5
94
86
80
76
92
85
80
76
83
79
75
82
78
75
80
77
74
6
89
81
75
71
88
80
75
71
79
74
70
77
73
70
76
72
70
7
Test No. 7051
Approved
Tested at 25ºC Ambient in accordance to IESNA LM-79-2008
65°
Zonal Cavity Method
COEFFICIENTS OF UTILIZATION
Room Cavity
Ratio
22.7W
E FOR THE
85
76
71
67
84
76
70
66
74
70
66
73
69
66
72
68
65
8
81
72
67
63
80
72
66
62
71
66
62
70
65
62
69
65
62
9
10
78
74
68
65
63
59
59
56
77
73
68
64
63
59
59
56
67
64
62
59
59
55
66
63
62
58
58
55
65
62
61
58
58
A2LED 2A9LED12L30K8FL35
FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
Web: www.prescolite.com • Tech Support: (888) 777-4832
701 Millennium Blvd.,• Greenville, SC 29607 U.S.A. • Phone (864) 678-1000
Copyright ©2015 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved
Specifications subject to change without notice. • Printed in U.S.A. • ARCH-LED-012 • 7/11/16
55
Test No. 7051
PHOTOMETRIC DATA
Central Inverters
For full fixture output in back-up mode, we recommend you visit www.dual-lite.com for your Central Lighting Inverter options. Please contact your local
Hubbell representative for any assistance with proper sizing and loading of your inverter selection. Central lighting inverters must be ordered
separately.
LiteGear: www.dual-lite.com/products/litegear_lg_series
LPS Series: www.dual-lite.com/products/lps
INSTALLATION HINTS
Daisy Chain:
Often times through branch wiring (Daisy Chaining) will be desired for installation of the A2LED in an application. There is one knock out available in
the J-tube for the line voltage, and one for the low voltage control wires. To accomplish 2in/2out through branch wiring. Prescolite suggests the use of
an Arlington Duplex Connector (PN 4040AST).
Ceiling Cut-out:
Due to the discrete trim flange on the A2LED, the accuracy of the 2-7/8" ceiling cut-out is critical to achieving the best results. Prescolite recommends
making this cut-out with a 2-7/8" hole saw, such as one manufactured by the Morse Company (TAC46 and TACPD4).
Ceiling Clearance:
When using the standard driver and J-Tube, 8" of plenum clearance is recommended when no top access is available to the J-Tube
Dimming Compatibility Table
Dimming Driver
Standard/DM01
Standard/DM01
HDM
LDM
Manufacturer
Lutron DVTV
Leviton AWRMG-7xx,
AWSMG-7xx,
AWSMT-7xx
Lutron
Lutron MAELV-600,
SPSELV-600,
NTELV-300
Leviton 6615-P,
6672-1LW,
6674
Web Link
http://bit.ly/11jSvZg
http://bit.ly/1BJn2R9
http://bit.ly/1vtjHAl
http://bit.ly/K28so2
http://bit.ly/1bfUNhe
http://bit.ly/1K28ziA
http://bit.ly/1DlPktd
http://bit.ly/1DcDlWr
http://bit.ly/1vWD8Sk
Web: www.prescolite.com • Tech Support: (888) 777-4832
701 Millennium Blvd.,• Greenville, SC 29607 U.S.A. • Phone (864) 678-1000
Copyright ©2015 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved
Specifications subject to change without notice. • Printed in U.S.A. • ARCH-LED-012 • 7/11/16
PHOTOMETRIC DATA
Frame Accessories
8" X 8"
POLYCARBONATE
CUTOUT AREA
1"
11-5/8"
FLEX
CONDUIT
HOLDING
CLIPS
SEISMIC
TETHER
14-3/8"
2-1/4"
D2FRM
D2FRM
*Note: Ceiling thickness maximum when using D2FRM is 1". Bar hangers not included, order B6 for ceiling joists up to 24"
centers or B24 for T-bar ceilings.
*Note: The standard product is designed and listed to be installed into most ceiling types without the use of an accessory
frame. These frames are provided as an optional accessory to be used when desired by the end user to provide extra support or required by local code.
Web: www.prescolite.com • Tech Support: (888) 777-4832
701 Millennium Blvd.,• Greenville, SC 29607 U.S.A. • Phone (864) 678-1000
Copyright ©2015 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved
Specifications subject to change without notice. • Printed in U.S.A. • ARCH-LED-012 • 7/11/16