2" LED Adjustable DATE:TYPE: A2LED FIRM NAME: PROJECT: High Output APPLICATIONS: LED LIGHT ENGINE: J-TUBE ASSEMBLY: LED DRIVER: Architektuˉr A2LED Series is a 2” specification grade LED Adjustable Luminaire that combines superior brightness control with energy savings and low maintenance costs. Suitable for a variety of commercial, retail, and institutional applications with ambient temperatures up to 35ºC (9L) 25ºC (12L) during operation with free airflow around the fixture. High output Xicato XSM LED Module (IP66 rated). Color consistency held to less than 2 SDCM's for fixture to fixture and over-time color consistency. Secured to an extruded aluminum heat sink for excellent thermal management providing optimal life and lumen maintenance (minimum 50,000 hours at 70% lumen maintenance). Utilizing Prescolite's revolutionary J-Tube design and optimal thermal management, the A2LED eliminates the need for a traditional downlight housing. The J-Tube assembly combines the traditional J-Box and driver electronics into a compact form that can be accessed from below the ceiling plane. These features allow the A2LED to ship as a single unit which can be completely wired and installed from below the ceiling plane. It can also be easily removed from below the ceiling if servicing or an upgrade to new technology is ever required. VOLTAGE ❑BLANK 120V ❑277 277V 2-1/4" 3-1/8" 5-1/4" WARRANTY: A EXAMPLE: A2LED277V-2A9LED 30K8FL35WCWT 5-1/4" ❑2A9LED 2" Open Reflector/ Light Engine Assembly with Xicato module ❑9L1 900 Delivered Lumens ❑12L1 1200 Delivered Lumens ❑27K 2700 Kelvin ❑30K 3000 Kelvin ❑35K 3500 Kelvin ❑40K 4000 Kelvin LOWER REFLECTOR FINISH 30° CRI ❑8 Nominal 80+ CRI ❑9 Nominal 95 CRI BEAM ANGLE ❑Blank Specular ❑SS Semi-Specular ❑MFC7 American Matte™ ❑FL35 Spun Aluminum relfector with a 35º flood distribution 1 See page 2 for specific lumen per module and raw lumens 2 See Central Inverter compatibility note and web links on page 3. 3 See page 4 for line art 4 Either CT, WT, or BT must be specified with a painted cone 5 With Alzak finishes, flange will match the trim finish. WT or BT may be specified as needed. 6 Upper reflector is always specular clear alzak 7 Not available with BC or WC OPTIONS STANDARD LOWER HDM LDM REFLECTOR DM01 COLORS J-TUBE DIM "A" 7-3/4" 16-1/4" 6" 10" ❑Blank Clear Alzak ❑CG Champagne Gold Alzak ❑BL Black Alzak ❑WE Wheat Alzak ❑LW Light Wheat Alzak ❑PW Pewter Alzak ❑BC4 Black Painted Cone ❑WC4 White Painted Cone DIM "B" 9-1/2" LOWER 18" 7-3/4" REFLECTOR 11-3/4" OPTIONS _ ❑Blank4,5 Anodized Trim ❑CT4 Clear Trim ❑WT4 White Trim ❑BT4 Black Trim • Tech Support: (888) 777-4832 ACCESSORIES ❑LiteGear2 Inverter, single phase central lighting, 125VA-250VA ❑ LPS Series2 LitePower micro-inverter, 20VA-55VA ❑D2FRM3 Optional Mounting frame for the A2LED fixture. LOWER REFLECTOR ANGLE CUT ❑Blank Standard Slot to accomodate 30º aiming ❑AC15 Slot to accomodate 15º aiming ❑FC Full cut for vertical aiming only In a continuing effort to offer the best product possible we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Web: www.prescolite.com DIM "B" 9-1/2" 18" 7-3/4" 11-3/4" LINE VOLTAGE CONDUIT OPENING B 3-1/8" LED COLOR DIM "A" 7-3/4" 16-1/4" 6" 10" KNOCK-OUT 0-10V DIMMING MODELS ONLY 2-1/2" 2-7/8" CEILING 5 Year Warranty. Go CUTOUT* to www. prescolite.com for full details. OUTPUT J-TUBE *Note: The accuracy of the 2-7/8" ceiling cutout is critical to the proper fit of the D2LED. For installation hints see page (?) or download the instruction sheet from www.prescolite.com 6-1/2" LIGHT ENGINE A Division of Hubbell Lighting, Inc. OPTIONS STANDARD HDM LDM DM01 30° CSA C/US certified to UL1598. Suitable for damp locations. Non–IC 2-3/4" rated and 2IN/2OUT through branch wiring. For connection to flexible conduit only. Order housing, reflector, and accessories separately ❑BLANK Standard 0-10V dimming ❑HDM Lutron Hi-Lume A-Series 3-wire or EcoSystem dimming to 1% ❑LDM Leading Edge dimming to 10% (12L & 120V only) ❑DM01 ELDO LED 0-10V dimming to less than 1%. B 2-1/4" _ 2-1/2" 2-7/8" CEILING CUTOUT* CERTIFICATIONS: CATALOG NUMBER: ❑A2LED 2" J-Tube Assembly with 0-10V Dimming standard. 6-1/2" Comes standard with 0-10V standard dimming capability. Flicker-free dimming to 10%. For sizing control systems, the 0-10V control circuit will draw up to 1 mA. Also available with 0-10V to below 1%, Lutron Ecosystem to 1%, and Leading Edge to 10%. A smooth 35º optical pattern is adjustable up to 30º from vertical. The vertical aiming must be adjusted and locked before installation. Prescolite's spring loaded retention allows 360º horizontal aiming during installation. OPTIONS A DIMMING: High purity spun aluminum self-flanged reflector with iridescence suppressed Alzak anodized finish. The lower reflector is also available with Prescolite's American Matte finish (MFC). *Note: The accuracy of the 2-7/8" ceiling cutout is critical to the proper fit of the D2LED. For installation hints see page (?) or download the instruction sheet from www.prescolite.com 2-3/4" Energy efficient electronic constant current driver with 50,000 hour minimum anticipated life. Meets UL Class 2, FCC 47CFR Part 15, Class B compliant, inherent short-circuit protection, self limited, overload protected. REFLECTOR & OPTICS: J-TUBE ASSEMBLY Ceiling Cutout: 27/8" Ceiling Thickness 1/2"-1 1/4" For conversion to millimeters, multiply inches by 25.4 Not to Scale ARCH-LED-012 PHOTOMETRIC DATA Architektū ¯r - 2" A2LED Downlight ELECTRICAL DATA A2LED9L8 A2LED9L9 A2LED12L8 Input Voltage 120/277V 120/277V 120/277V Input Frequency 50/60 Hz 50/60 Hz 50/60 Hz Input Current 0.14/0.062 0.170/.076 0.20/0.087 Input Power 17 Watts 21 Watts 24 Watts Constant Current Output 760mA 760mA 700mA Power Factor ≥0.90 ≥0.90 ≥0.90 EMI Filtering FCC 47CFR FCC 47CFR FCC 47CFR Part 15, Class B Part 15, Class B Part 15, Class B Fixture Operating Temperature -30ºC to 35ºC -30ºC to 35ºC -30ºC to 25ºC Dimming 0-10V to 10% 0-10V to 10% 0-10V to 10% Over-voltage, over-current, (short-circuit protected, and over-temperature protection with auto recovery) 7 95 CRI 12L 1.0 .66 9L 0.71 0.57 NVLAP LAB CODE: 201003-0 om -30ºC to 25ºC 0-10V to 10% Xicato Module Chart Lumen Multiplier For CRI Options 80+ CRI® A2LED12L9 120/277V 50/60 Hz 0.18/0.08 22 Watts 700mA ≥0.90 FCC 47CFR Part 15, Class B 12L *For exact lumen outputs, please visit www.prescolite.com to find IES reports 9L PAGE: 2 OF 6 DATE SAMPLE TESTED: 07/15/13 35 HIGH OUTPUT 3000K HIGH OUTPUT] 80+ CRI 95 CRI 2000 1300 1420 930 1300 1000 1000 800 Drive Current Xicato XSM Module 700 mA Module Delivered Lumens Xicato XSM Module 760 mA Module Delivered Lumens Drivers ZONE CANDELA DISTRIBUTION 90˚ 90º 75˚ 75º 450 450 60˚ 60º 900 900 45˚ 45º 9 R 1350 1350 0º0˚ 15˚ 15º DEG 0 5 15 25 35 45 55 65 75 85 90 LUMENS %LUMINAIRE 0-30 870 79.2 0-40 1052 95.9 0-60 1097 99.9 0-90 1098 100.0 0-180 1098 100.0 CANDELA LUMENS 1255 1250 1220 934 262 48 3 1 0 0 0 119 341 409 183 42 3 1 0 0 30˚ 30º Checked LUMINANCE DATA IN CANDELA/ SQ. METER Angle in Vertical Average - 0º 45° 26453 55° 2038 ZONAL LUMEN SUMMARY A2LED 2A9LED12L30K8FL35 LED Light Engine: 3000K, 80 CRI System Wattage: 22.7 Fixture delivered lumens: 1098 Spacing Criteria: 0.9 922 75° 85° 0 0 % Effective Ceiling Cavity Reflectance 80% 70% 50% 30% 10% 20% Effective Floor Cavity Reflectance % Wall Reflectance 10 50 30 1 2 114 111 109 107 111 109 107 105 105 103 102 101 100 99 109 104 100 97 106 102 99 96 99 96 94 96 94 92 98 93 97 91 96 90 3 103 97 89 86 84 4 70 50 30 10 70 99 91 93 86 50 89 101 96 82 97 90 30 92 85 10 50 30 10 50 88 82 93 88 90 84 87 81 91 86 30 88 83 85 80 84 81 10 79 5 94 86 80 76 92 85 80 76 83 79 75 82 78 75 80 77 74 6 89 81 75 71 88 80 75 71 79 74 70 77 73 70 76 72 70 7 Test No. 7051 Approved Tested at 25ºC Ambient in accordance to IESNA LM-79-2008 65° Zonal Cavity Method COEFFICIENTS OF UTILIZATION Room Cavity Ratio 22.7W E FOR THE 85 76 71 67 84 76 70 66 74 70 66 73 69 66 72 68 65 8 81 72 67 63 80 72 66 62 71 66 62 70 65 62 69 65 62 9 10 78 74 68 65 63 59 59 56 77 73 68 64 63 59 59 56 67 64 62 59 59 55 66 63 62 58 58 55 65 62 61 58 58 A2LED 2A9LED12L30K8FL35 FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. Web: www.prescolite.com • Tech Support: (888) 777-4832 701 Millennium Blvd.,• Greenville, SC 29607 U.S.A. • Phone (864) 678-1000 Copyright ©2015 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved Specifications subject to change without notice. • Printed in U.S.A. • ARCH-LED-012 • 7/11/16 55 Test No. 7051 PHOTOMETRIC DATA Central Inverters For full fixture output in back-up mode, we recommend you visit www.dual-lite.com for your Central Lighting Inverter options. Please contact your local Hubbell representative for any assistance with proper sizing and loading of your inverter selection. Central lighting inverters must be ordered separately. LiteGear: www.dual-lite.com/products/litegear_lg_series LPS Series: www.dual-lite.com/products/lps INSTALLATION HINTS Daisy Chain: Often times through branch wiring (Daisy Chaining) will be desired for installation of the A2LED in an application. There is one knock out available in the J-tube for the line voltage, and one for the low voltage control wires. To accomplish 2in/2out through branch wiring. Prescolite suggests the use of an Arlington Duplex Connector (PN 4040AST). Ceiling Cut-out: Due to the discrete trim flange on the A2LED, the accuracy of the 2-7/8" ceiling cut-out is critical to achieving the best results. Prescolite recommends making this cut-out with a 2-7/8" hole saw, such as one manufactured by the Morse Company (TAC46 and TACPD4). Ceiling Clearance: When using the standard driver and J-Tube, 8" of plenum clearance is recommended when no top access is available to the J-Tube Dimming Compatibility Table Dimming Driver Standard/DM01 Standard/DM01 HDM LDM Manufacturer Lutron DVTV Leviton AWRMG-7xx, AWSMG-7xx, AWSMT-7xx Lutron Lutron MAELV-600, SPSELV-600, NTELV-300 Leviton 6615-P, 6672-1LW, 6674 Web Link http://bit.ly/11jSvZg http://bit.ly/1BJn2R9 http://bit.ly/1vtjHAl http://bit.ly/K28so2 http://bit.ly/1bfUNhe http://bit.ly/1K28ziA http://bit.ly/1DlPktd http://bit.ly/1DcDlWr http://bit.ly/1vWD8Sk Web: www.prescolite.com • Tech Support: (888) 777-4832 701 Millennium Blvd.,• Greenville, SC 29607 U.S.A. • Phone (864) 678-1000 Copyright ©2015 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved Specifications subject to change without notice. • Printed in U.S.A. • ARCH-LED-012 • 7/11/16 PHOTOMETRIC DATA Frame Accessories 8" X 8" POLYCARBONATE CUTOUT AREA 1" 11-5/8" FLEX CONDUIT HOLDING CLIPS SEISMIC TETHER 14-3/8" 2-1/4" D2FRM D2FRM *Note: Ceiling thickness maximum when using D2FRM is 1". Bar hangers not included, order B6 for ceiling joists up to 24" centers or B24 for T-bar ceilings. *Note: The standard product is designed and listed to be installed into most ceiling types without the use of an accessory frame. These frames are provided as an optional accessory to be used when desired by the end user to provide extra support or required by local code. Web: www.prescolite.com • Tech Support: (888) 777-4832 701 Millennium Blvd.,• Greenville, SC 29607 U.S.A. • Phone (864) 678-1000 Copyright ©2015 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved Specifications subject to change without notice. • Printed in U.S.A. • ARCH-LED-012 • 7/11/16