DIN-110MAZ Data Sheet

advertisement
Safety
Signal
Control
Zippswitch Products
281C Skip Lane ∞ Bay Shore ∞ NY ∞ 11706
Phone 631.667.0659 ∞ 631.667.0268 Fax
www.zippswitch.com ∞ sales@zippswitch.com
Zippswitch Sensor
Patent No. 7,659,485
Safety Control Relay
Specifications
Model DIN-110MAZ
The DIN-110MAZ is a Safety Control Relay
designed to interface Safety Mats, Safety Edges,
and Zippswitch Sensors to a Machine. When the
Safety Sensor is tripped, the Safety Control
Relay will remove power to the machine.
Controller Type:
Safety Category:
Relay Type:
Voltage:
Power Consumption:
Response Time:
Mechanical Endurance:
Operating Temperature:
Enclosure Type:
Enclosure Dimensions:
Reset:
LED Indicators:
Number of Safety Outputs:
Safety Contact Rating:
Switching Load:
Safety Relay Controller
4
Force-Guided Safety Relays
110/230VAC
12 VA
< 50 ms
10 x 10⁶ cycles
0° to 122 °F (-18 to 50 °C)
35mm DIN Rail
2.76” x 2.57” x 4.42”
Manual, Automatic or Monitored
Power, Output Status
2 N/O Force Guided Contacts
6 Amps Max
400 VAC Max
Rated for Resistive Loads
Multi-Sensor Connection Diagram
Contact us today to discuss the benefits of using Zippswitch Products in your application.
Safety Switch Mats
Zippswitch Sensing Technology
Safety & Signal
Electronic Controllers
Impact & Collision Sensing
Edges & Bumpers
Zippswitch Products are Designed & Manufactured in the USA. US & International Patented and Patents Pending. © 2006 - 2010
Transit Passenger
Signal Switches
Safety
Signal
Control
Zippswitch Products
281C Skip Lane ∞ Bay Shore ∞ NY ∞ 11706
Phone 631.667.0659 ∞ 631.667.0268 Fax
www.zippswitch.com ∞ sales@zippswitch.com
Zippswitch Sensor
Patent No. 7,659,485
Safety Control Relay
Model DIN-110MAZ
Connection
Terminal 1
Line
Terminal 2
Neutral
Terminal 3
Terminal 4
YOU MUST CONNECT either a jumper wire OR a Normally Open
Momentary Switch across terminals 3 & 4.
The Safety Controller will remain OFF if this step is not followed.
A jumper wire across 3 & 4 will provide an Automatic Reset.
A Normally Open Momentary Switch across 3 & 4 will provide a
Manual Reset.
See Below for Monitored Output Connection.
Terminal 5
Black
Terminal 6
White
Terminal 7
Red
Terminal 8
Green
Terminal 9
Terminal 10
Terminal 11
Terminal 12
110/230VAC
DIN RAIL
2.7”x2.5”x4.4”
N/O Output 1
N/O Output 2
Automatic Reset
When Automatic Reset mode is chosen, the Safety Control Relay will energize and close the Output Contacts when power is
applied to the Safety Control relay and the Sensor is clear. An Automatic Reset condition is when the Zippswitch Sensor is
pressed; Outputs 1 & 2 will open. When the Zippswitch Sensor is released (clear), Outputs 1 & 2 will close automatically. Do
not use Automatic Reset if the risk of an unsafe condition is present when power is applied to the Safety Control Relay and the
Sensor is clear.
Manual Reset
When Manual Reset mode is chosen and Power is applied to the Safety Control Relay, the Reset switch will need to be pressed
to energize and close the Outputs. A Manual Reset condition is when the Zippswitch sensor is pressed; Outputs 1 & 2 will open.
Reset will only occur when the Normally Open Momentary Switch across terminals 3 & 4 is pressed then Outputs 1 & 2 will
close. Manual Reset provides a higher degree of safety.
Monitored Output
A Monitored Output Circuit will prevent the Safety
Control Relay from Reseting if an output contact
welds to a closed state. The Outputs of the Safety
Control Relay can be monitored by using External
Force Guided Safety Relays at the Outputs of the
Safety Control Relay. See Diagram.
Using type 1 N/O - 1 N/C Force Guided Relays will
enable the circuit to monitor the state of each
Output Relay. If one of the External Force Guided
Relays were to have the Contacts Weld and
remain closed, after the sensor is pressed and
released, the Reset Circuit will will not be able to
be reset until the fault is corrected.
When Monitored Output mode is chosen and
Power is applied to the Safety Control Relay, the
Reset switch will need to be pressed to energize
and close the Outputs. If a fault is detected in the
Output Circuit, The Safety control Relay will not
energize.
Contact us today to discuss the benefits of using Zippswitch Products in your application.
Safety Switch Mats
Zippswitch Sensing Technology
Safety & Signal
Electronic Controllers
Impact & Collision Sensing
Edges & Bumpers
Zippswitch Products are Designed & Manufactured in the USA. US & International Patented and Patents Pending. © 2006 - 2010
Transit Passenger
Signal Switches
Download