WALL SLOT PRE-HARD PAN INSTALLATION INSTRUCTIONS
NOTE: This fixture ships unassembled.
1.
Install wall angle (by other) on wall offset
upward by sheet rock thickness. Wall track
installs on wall 9” above wall angle.
2. Assemble mounting bracket, cartridge and
reflector on floor.
2A. All screws to hold fixture together are
installed from inside.
2B. Pay close attention to how tab on reflector
holder goes into cartridge slot.
H.E. Williams, Inc. • Carthage, Missouri • www.hewilliams .com • 417-358-4065 • Fax: 417-358-6015
PAGE 1
WALL SLOT PRE-HARD PAN INSTALLATION INSTRUCTIONS
3. Determine location of power supply for the
fixture. The back of the cartridge has a KO
on either end. The 6’ and 8’ lengths also have
one in the center. There is also a KO on each
end plate which can work for either power
feed or quick connect harness.
6. If it’s desired to extend the lamp slider
(standard on 2 lamp cross-sections) loosen
the screws shown and move the lamp slider
either way. Retighten the screws once the
location is reached.
4. Lift fixture onto wall track, install tie wires.
Attach reflector holder to wall. Make sure
fixture is level and straight. If necessary,
straighten wall track if the mounting wall
is crooked.
7. Insert reflector and rest on wall angle as
shown and install #8 point screws.
5. On row applications, align fixtures. Use
#8x1/4” screws in locations shown on end
plates. Reflector mounting holes also need
to be aligned as shown. Failure to follow
this step will make it impossible to align
the fixtures.
7A. Place wireway cover under clips on lamp
slider, then squeeze and insert tabs into
slots on cartridge. If louver is used it hooks
over cartridge hook with the other side
resting on the wall angle. Finished sheetrock
opening is to be 8-1/2”.
H.E. Williams, Inc. • Carthage, Missouri • www.hewilliams .com • 417-358-4065 • Fax: 417-358-6015
PAGE 2
WALL SLOT PRE-GRID INSTALLATION INSTRUCTIONS
1.
Install wall angle (by other) on wall level with
intended ceiling grid. Wall track installs on
wall 9” above wall angle.
2. Assemble mounting bracket, cartridge and
reflector on floor.
2B. Pay close attention to how tab on reflector
holder goes into cartridge slot.
3. Determine location of power supply for the
fixture. The back of the cartridge has a KO
on either end. The 6’ and 8’ lengths also have
one in the center. There is also a KO on each
end plate which can work for either power
feed or quick connect harness.
2A. All screws to hold fixture together are
installed from inside.
4. Lift fixture onto wall track, install tie wires.
Attach reflector holder to wall. Make sure
fixture is level and straight. If necessary,
straighten wall track if the mounting wall
is crooked.
H.E. Williams, Inc. • Carthage, Missouri • www.hewilliams .com • 417-358-4065 • Fax: 417-358-6015
PAGE 3
WALL SLOT PRE-GRID INSTALLATION INSTRUCTIONS
5. On row applications, align fixtures. Use
#8x1/4” screws in locations shown on end
plates. Reflector mounting holes also need
to be aligned as shown. Failure to follow
this step will make it impossible to align
the fixtures.
6. If it’s desired to extend the lamp slider
(standard on 2 lamp cross-sections) loosen
the screws shown and move the lamp slider
either way. Retighten the screws once the
location is reached.
7A. Place wireway cover under clips on lamp
slider, then squeeze and insert tabs into
slots on cartridge. If louver is used it hooks
over cartridge hook with the other side
resting on the wall angle.
8. After installation of ceiling grid determine
locations for EQ clips and install using
provided 8-32x1/2” screws. Multiple EQ clip
locations are provided to accommodate
different ceiling structures.
7. Insert reflector and rest on wall angle as
shown and install #8 point screws.
H.E. Williams, Inc. • Carthage, Missouri • www.hewilliams .com • 417-358-4065 • Fax: 417-358-6015
PAGE 4
WALL SLOT POST-HARD PAN INSTALLATION INSTRUCTIONS
1.
Opening preparation, by others: sheetrock
must be installed with an 8-1/2” opening as
shown with a stud laid on edge at 9” from
the wall, edge of sheetrock to be capped
with J-Trim. Install grid ceiling wall angle on
wall. Offset angle upwards by thickness of
the sheetrock.
3. Determine location of power supply for
fixture. The back of the cartridge has a KO
on either end. The 6’ and 8’ lengths also have
one in the center. There is also a KO on each
end plate which can work for either a power
feed or quick-connect harness.
4. Lift fixture into opening by folding reflector
holder in. Once inside spread them out and
rest the cartridge on the stud and reflector
holder on the wall angle.
2. Assemble mounting bracket, cartridge and
reflector on floor.
2A.
4A.
Insert #8 screw on each end of reflector
holder to hold the fixture open.
4B.
Attach cartridge and reflector holder to
stud and wall as shown.
All screws to hold fixture together are
installed from inside. Pay attention to how
tabs on reflector holder goes into the
cartridge slot.
H.E. Williams, Inc. • Carthage, Missouri • www.hewilliams .com • 417-358-4065 • Fax: 417-358-6015
PAGE 5
WALL SLOT POST-HARD PAN INSTALLATION INSTRUCTIONS
5. On row applications, align fixtures. Use
#8x1/4” screws in locations shown on end
plates. Reflector mounting holes also need
to be aligned as shown. Failure to follow
this step will make it impossible to align
the fixtures.
7. Insert reflector and rest on wall angle as
shown and install with #8 point screws.
7A.
6. If it’s desired to extend the lamp slider
(standard on 2 lamp cross-sections) loosen
the screws shown and move the lamp slider
either way. Retighten the screws once the
location is reached.
Place wireway cover under clips on lamp
slider, then squeeze and insert tabs into
slots on cartridge. If louver is used it
hooks over cartridge hook with the other
side resting on the wall.
H.E. Williams, Inc. • Carthage, Missouri • www.hewilliams .com • 417-358-4065 • Fax: 417-358-6015
PAGE 6
WALL SLOT POST-GRID INSTALLATION INSTRUCTIONS
1.
Install ceiling system leaving 9” gap between
centerline of T-bar and wall. Install wall angle
(by other) on wall at same height as grid
system. If needed use a spacer to hold the
distance between grid system and wall to 9”.
4. Determine locations for EQ clips; install using
provided 8-32 x 1/2” screws. Multiple EQ
clip locations are provided to accommodate
different ceiling structures. Leave EQ clips
loose to fit over T-bar upon installation.
5. Insert lamp cartridge into ceiling and hook
onto reflector holder as shown.
2. Starting at one end attach reflector holder
to wall through provided holes using drywall
screws or nails. Remove and discard spacer
if used. When row mounting holders make
sure they are touching and aligned vertically
to each other.
3. Determine location of power supply for
fixture. The end of the cartridge has a KO
on either end. The 6’ and 8’ lengths also
have one in the center. There is also a KO
on each endplate which can work for either
a power feed or quick-connect harness.
5A.
Place against T-bar with EQ clips over
T-bar.
5B.
Attach cartridge to reflector holder using
#8 screws in locations shown and tighten
EQ clip screws.
H.E. Williams, Inc. • Carthage, Missouri • www.hewilliams .com • 417-358-4065 • Fax: 417-358-6015
PAGE 7
WALL SLOT POST-GRID INSTALLATION INSTRUCTIONS
6. On row applications, align fixtures. Use
#8x1/4” screws in locations shown on end
plates. Reflector mounting holes also need
to be aligned as shown. Failure to follow
this step will make it impossible to align
the fixtures.
9. Insert reflector and rest on wall angle as
shown and install with #8 point screws. Place
wireway cover under clips on lamp slider, then
squeeze and insert tabs into slots on cartridge.
9A.
If louver is used it hooks over cartridge
hook with the other side resting on wall.
7. If it’s desired to extend the lamp slider
(standard on 2 lamp cross-sections) loosen
the screws shown and move the lamp slider
either way. Retighten the screws once the
location is reached.
8. Pull out wire tie tabs on top side of cartridge
and tie fixture to ceiling support structure.
H.E. Williams, Inc. • Carthage, Missouri • www.hewilliams .com • 417-358-4065 • Fax: 417-358-6015
PAGE 8
WALL SLOT ROW FILLER INSTALLATION INSTRUCTIONS
1.
4. Insert channel and endplate assembly into
ceiling, hook earthquake clips over T-bar if
needed. Align endplates to adjacent fixtures
through provided screw holes, and finish
tightening endplates to channel.
Measure opening for length. Go from
corner of wall to nearest WS fixture.
Filler adjustment range, 2”-14”.
Tools: Tape measure
2. Layout
and be
before
will be
and trim these parts. Refer to diagram
certain each part is oriented correctly
marking and cutting. All cut edges
hidden when assembly is finished.
Tools: /4 ” socket, #8 screws
1
Tools: Combination square, marker or pencil,
tape measure, and aviation snips. A hammer
is handy for flattening parts back into shape
after cutting.
a.
Channel, subtract /8 ” from the opening
measurement. Cut on end opposite wall.
b.
Wireway cover, subtract /16 ” from the
opening measurement. IMPORTANT, cover
must be cut on the same end as Channel.
c.
Louver Hook (if needed). Subtract /16 ”
from the opening measurement. Using tin
snips add notch on cut end to match the
one cut off.
1
3
3
5. Bend tabs on large endplate and mount
against wall. Tabs will bend to either side
as needed. Use drywall screws to secure
to wall, and sheet metal screws against
the channel.
Tools: /4 ” socket, #8 screws,
drywall screws (provided by others)
1
Note: Wall not shown for clarity
3. Assemble left and right endplate to channel.
Leave endplates slightly loose (optional,
attach earthquake clips, louver hooks).
Screws go from inside fixture.
Tools: /4 ” socket, #8 screws
1
6. Screw wireway cover into channel and screw
down as needed. If power needs to be run
between the fixtures on either side of the
corner it goes inside the wireway cover.
Tools: /4 ” socket, #8 screws
1
H.E. Williams, Inc. • Carthage, Missouri • www.hewilliams .com • 417-358-4065 • Fax: 417-358-6015
PAGE 9
WALL SLOT ROW FILLER INSTALLATION INSTRUCTIONS
7. Peel vinyl cover off of and mount reflectors.
The reflectors are NOT cut, but are slid
behind the reflectors on adjacent fixtures.
Screw into reflector holder.
Tools: /4 ” socket, #8 screws
1
Note: Due to the short length a reflector
holder is not needed
9. If needed trim louver to length and insert.
One side of louver hangs on louver hook
with the other side resting on the wall angle.
To trim for length a bandsaw is ideal. If not
available use aviation snips and flatten back
out after cutting.
Tools: bandsaw or aviation snips, hammer
8. Attach wireway cover trims over cut ends on
each end of wireway cover with supplied
VHB tape.
Tools: Utility knife, VHB tape
H.E. Williams, Inc. • Carthage, Missouri • www.hewilliams .com • 417-358-4065 • Fax: 417-358-6015
PAGE 10