Flat Twin, PVC Insulated, Low Voltage Cable 300/500V, SABS 1574, 70ºC Conductors: Annealed Copper Compacted – Class 2 Insulation: PVC Phase Color Code: Red & Black Application: Used for House/Building Wiring. FLAT TWIN PVC Insulated - 300/500V PHYSICAL PROPERTIES Approximate Phase Conductor Size Conductor Diameter Dimensions mm2 No./mm mm 0.5 0.9 3.0 x 6.0 0.75 1.14 3.2 x 6.4 1 1.13 4.7 x 8.6 1.5 1.38 5.6 x 10.0 2.5 1.78 6.2 x 11.5 4 2.55 7.2 x 13.0 6 3.12 8.0 x 15.0 10 4.05 9.6 x 19.0 16 5.25 11.0 x 22.5 ELECTRICAL PROPERTIES Cable Mass Coil length DC Resistance @ 20°C Current in Air (A) kg/km 41 50 58 85 120 179 230 337 481 m 100 100 100 100 100 100 100 100 100 Ω/km/phase 39.00 26.00 18.10 13.60 7.41 4.61 3.08 1.83 1.15 3 6 10 21 30 39 50 68 91 Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Flat Twin & Earth, PVC Insulated, Low Voltage Cable 300/500V, SABS 1574, 70ºC Conductors: Annealed Copper Compacted – Class 2 Insulation: PVC Phase Color Code: 2 Cores -Red & Black 3 Cores – Red , Yellow & Blue 4 Cores – Red, Yellow, Blue, Black Application: Used for House/Building and factory wiring. FLAT TWIN PVC Insulated - 300/500V PHYSICAL PROPERTIES Approximate Phase Conductor Size Earth Conductor Wires Dimensions mm2 mm2 mm 1 1 4.7 x 11 1.5 1 5.4 x 12.5 2.5 1.5 6.2 x 14.5 4 2.5 7.4 x 18 6 4 8.0 x 20.0 10 6 9.6 x 25.5 16 10 11 x 29.5 ELECTRICAL PROPERTIES Cable Mass Coil Length DC Resistance @ 20°C Current in Air (A) kg/km 65 90 129 196 260 385 565 m 100 100 100 100 100 100 100 Ω/km/phase 18.10 13.60 7.41 4.61 3.08 1.83 1.15 16 21 30 39 50 68 91 Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. House Wire, Single Core PVC Insulated, Low Voltage Cable 0.6/1 kV, SABS 1507, 70ºC Conductors: Annealed Copper Compacted – Class 2 Insulation: PVC Phase Color Code: Red, Yellow, Blue, Black, Grn/Yellow, Orange, Pink, Violet, White or any color required by customer Application: Used for House/Building wiring. HOUSE WIRE PVC INSULATED - 600/1000V PHYSICAL PROPERTIES Phase Conductor Conductor Diameter Approximate Size Diameter mm2 mm mm2 1 1.13 2.8 1.5 1.5 3.1 2.5 1.9 3.5 4 2.4 4.4 6 2.9 4.9 10 3.7 5.7 16 4.8 6.8 25 6.1 8.5 35 7.1 9.5 50 8.2 11.0 70 9.9 12.7 95 11.7 14.9 120 13.4 16.6 150 14.6 18.2 185 16.4 20.4 240 18.8 23.2 300 21.4 26.2 400 24.3 29.5 500 27.3 32.9 630 31.0 36.6 800 35.1 40.7 1000 39.1 45.1 Cable Mass Drum kg/km 20 23 33 52 74 114 173 269 364 517 708 960 1199 1496 1847 2388 2980 3944 4913 6133 7716 9614 m 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 ELECTRICAL PROPERTIES DC Resistance @ Current unenclosed 20°C in Air (A) Ω/km/phase 18.100 14 12.100 18 7.410 25 4.610 33 3.080 43 1.830 59 1.150 82 0.727 111 0.524 136 0.387 166 0.268 214 0.193 261 0.153 303 0.124 350 0.099 418 0.075 490 0.060 570 0.047 652 0.060 773 0.050 872 0.030 996 0.030 1081 Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Ripcord, PVC Insulated, Low Voltage Cable 300/300V, SABS 1574, 70ºC Conductors: Flexible Copper – Class 5 Insulation: PVC Phase Color Code: White, Transparent or Black with identification thread or Black with Red Application: Used for House Lighting Appliances, Audio and Alarm Systems Ripcord - 300/300V Phase Conductor Size mm2 0.5 0.75 1 1.5 2.5 PHYSICAL PROPERTIES Approximate Conductor Diameter Dimensions mm2 mm 1 2.4 x 4.8 1.3 2.7 x 5.4 1.5 3.1 x 6.2 1.7 3.3 x 6.6 2.2 3.8 x 7.6 Cable Mass Coil Length kg/km 21 28 37 47 69 m 100 100 100 100 100 ELECTRICAL PROPERTIES DC Resistance @ Current in Air (A) 20°C Ω/km/phase 39.00 3 26.00 6 19.50 10 13.30 16 7.98 25 Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Welding Cable, Single Core PVC Nitrile Insulated, Low Voltage Cable 100V, SABS 1576, 70ºC Conductors: Flexible Copper – Class 5 Insulation: PVC-Nitrile ( Flexible Grade) Phase Color Code: As specified below or as per customer specification Application: Used for Electric Welding Equipment WELDING CABLE PVC NITRILE(FLEXIBLE GRADE) INSULATED - 100V PHYSICAL PROPERTIES Phase Approximate Cable Mass Drum Conductor Phase Colour Conductor Diameter Diameter Size mm2 16 25 35 50 70 95 120 Green Blue Grey Red Brown Yellow Black mm2 5.8 7.3 9.4 11.2 13.1 15.3 17.0 mm 10.4 11.8 13.9 16.2 18.4 21.1 23.1 kg/km 228 324 436 605 825 1098 1368 m 500 500 500 500 500 500 500 ELECTRICAL PROPERTIES DC Resistance @ 20°C Continuous Ω/km/phase rating @ 30°C 1.210 82 0.780 111 0.554 133 0.386 166 0.272 214 0.206 261 0.161 303 Current unenclosed in Air (A) 100% 140 189 227 283 365 445 516 Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. 5 Min. Period Duty Cycle 85% 60% 150 181 203 245 244 294 304 367 392 473 478 577 555 669 30% 254 344 412 514 663 808 939 GenFlex®, Single Core PVC Nitrile Insulated, Low Voltage Cable 1000V, SABS 1574, 70ºC Conductors: Flexible Copper – Class 5 Insulation: PVC-Nitrile ( Flexible Grade) Phase Color Code: Red or as requested by customer Application: Used for Panel and Instrument Wiring PANEL/INSTRUMENT WIRE PVC NITRILE INSULATED - 600/1000V PHYSICAL PROPERTIES Phase Conductor Approximate Conductor Diameter Size Diameter mm2 mm mm2 0.5 1 2.4 0.75 1.3 2.7 1 1.5 3.1 1.5 1.7 3.3 2.5 2.2 3.8 4 2.6 4.6 6 3.9 5.9 10 4.7 7.2 16 5.8 8.4 25 7.3 10.2 35 9.4 12.3 50 11.2 14.5 70 13.1 16.4 95 15.3 19.1 120 16.9 20.7 150 20.1 24.2 185 20.8 25.4 Cable Mass Coils/Drums kg/km 10 14 18 24 35 54 78 121 181 279 381 542 736 995 1234 1553 1901 m 100 100 100 100 100 100 100 100 100 500 500 500 500 500 500 500 500 ELECTRICAL PROPERTIES DC Resistance @ Current unenclosed 20°C in Air (A) Ω/km/phase 39.000 3 26.000 6 19.500 10 13.300 16 7.980 25 4.950 32 3.300 43 1.910 59 1.210 82 0.780 111 0.554 136 0.386 166 0.272 214 0.206 261 0.161 303 0.129 350 0.106 418 Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Interdac 3 Cable Low Voltage Power Cable 1.9/3.3 kV, SABS 1507, 90ºC, APL MDPE Sheath. Phase Conductors: Annealed Copper Compacted – Class 2 Earth Conductor: Tinned Annealed Copper – Class 2 Insulation: LV-XLPE Phase Color Code: Red, Yellow and Blue Application: Used to transfer power over long distances, e.g. supply power to farm water pump motors. INTERDAC 3 (1900/3300V) Cable Size Conductor Diameter Phase Core Diameter Phase Color Identification Tinned Bare Copper Earth Conductor Size Cable Overall Diameter Cable Mass Conductor resistance (DC Resistance @ 20°C) Conductor resistance (AC Resistance @ 90°C) Conductor Impedance (Z) Current (A) Symmetrical Short Circuit current (1 Sec.) PHYSICAL PROPERTIES 10 16 3.83 4.75 8.83 9.75 Red, Yel & Blue Red, Yel & Blue 10 25 6.1 11.1 Red, Yel & Blue UNITS mm2 mm mm 16 25 mm2 26.4 903 29.4 1071 mm kg/km UNITS 1.830 1.150 0.727 Ω/km 2.19 1.38 0.93 Ω/km 2.340 80 1.474 103 0.934 130 Ω/km A 1.4 2.3 3.6 kA 24.2 324 ELECTRICAL PROPERTIES Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Armoured XLPE Low Voltage Power Cable 0.6/1 kV, SABS 1507, 90ºC, PVC-FR Sheath. Conductor: Annealed Copper or Aluminium Compacted – Class 2 Insulation: LV-XLPE Phase Color Code: Red or Black Application: Used for reticulation and underground power supply. Outer sheath can also be stripped blue or white. 600/1000V - 1 Cores XLPE AWA PHYSICAL PROPERTIES Insulation Cable Core Overall Screen Cable Mass Size Diam. Diameter Diam. mm2 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000 mm 4.8 6.1 7.1 8.2 9.9 11.7 13.4 14.6 16.4 18.8 21.4 24.3 27.3 31.0 35.1 39.1 mm 6.2 7.9 8.9 10.2 12.1 13.9 15.8 17.4 19.6 22.2 25.0 28.3 31.7 35.8 40.3 44.7 mm 13.3 15.0 16.0 17.3 19.4 21.2 24.1 25.7 28.8 31.4 35.4 39.5 42.9 48.8 53.3 58.1 CU AL kg/km 342.7 242.7 463.1 306.9 576.8 358.1 742.0 429.6 974.3 536.9 1242.4 648.8 1572.2 822.4 1891.9 954.5 2351.9 1195.9 2929.0 1429.2 3681.9 1807.2 4778.5 2279.0 5823.5 2699.1 7411.1 3474.3 9143.1 4144.0 11206.2 4957.3 Drum length DC Resistance @ 20°C m 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 CU AL Ω/km/phase 1.15 1.91 0.73 1.20 0.52 0.87 0.39 0.64 0.27 0.44 0.19 0.32 0.15 0.25 0.12 0.21 0.10 0.16 0.08 0.13 0.06 0.10 0.05 0.08 0.04 0.06 0.03 0.05 0.02 0.03 0.02 0.03 ELECTRICAL PROPERTIES Sym. Asym. AC Resistance Impedance Current, in Current,in @ 90°C 1sec 1sec CU AL CU AL CU AL Ω/km/phase Ω/km/phase kA 1.47 2.420 1.47 2.460 2.3 1.5 2.6 0.93 1.540 0.93 1.542 3.5 2.3 3.0 0.67 1.110 0.68 1.11 5.0 3.3 3.4 0.49 0.820 0.52 0.84 7.2 4.7 3.7 0.34 0.570 0.37 0.59 10.0 6.6 4.2 0.25 0.410 0.28 0.43 13.6 9.0 4.8 0.2 0.330 0.24 0.350 17.2 11.3 5.4 0.16 0.270 0.2 0.29 21.5 14.2 5.9 0.13 0.210 0.18 0.24 26.5 17.5 8.5 0.1 0.160 0.15 0.200 34.3 22.7 9.5 0.08 0.130 0.14 0.17 42.9 28.3 13.4 0.06 0.100 0.13 0.15 57.2 37.8 14.8 0.05 0.080 0.120 0.14 71.5 47.2 16.6 0.04 0.060 0.11 0.12 90.1 59.5 23.7 0.04 0.042 0.039 0.045 114.4 73.6 26.0 0.03 0.038 0.034 0.040 143.0 92.0 28.3 Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Current (I) Ground CU 91 117 147 174 217 261 304 342 388 456 525 596 693 778 843 895 Air AL CU Amps 71 88 93 114 113 147 135 174 169 223 203 242 236 269 266 361 303 410 356 488 412 573 473 652 556 773 675 872 702 996 774 1081 AL 69 92 113 136 173 209 248 280 364 381 450 518 622 712 918 963 Armoured XLPE Low Voltage Power Cable 1.9/3.3 kV, SABS 1507, 90ºC, PVC-FR Sheath. Conductor: Annealed Copper or Aluminium Compacted – Class 2 Insulation: LV-XLPE Phase Color Code: Red or Black Application: Used for reticulation and underground power supply . Outer sheath can also be stripped blue or white. 1900/3300V - 1 Cores XLPE AWA PHYSICAL PROPERTIES Insulation Cable Core Overall Screen Cable Mass Size Diam. Diameter Diam. CU mm2 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000 mm 4.8 6.1 7.1 8.2 9.9 11.7 13.4 14.6 16.4 18.8 21.4 24.3 27.3 31.0 35.1 39.1 mm 8.8 10.1 11.1 12.2 13.9 15.7 17.4 18.6 20.4 22.8 25.4 28.3 31.7 35.8 40.3 44.7 mm 15.9 17.2 18.4 19.5 21.2 23.0 25.7 26.9 29.6 32.0 35.8 39.5 42.9 48.8 53.3 58.5 ELECTRICAL PROPERTIES Drum length DC Resistance @ 20°C AC Resistance @ 90°C Impedance m 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 CU AL Ω/km/phase 1.15 1.91 0.727 1.2 0.524 0.87 0.387 0.640 0.268 0.440 0.193 0.320 0.153 0.250 0.124 0.210 0.099 0.160 0.075 0.130 0.060 0.100 0.047 0.080 0.037 0.060 0.028 0.050 0.021 0.033 0.019 0.032 CU AL Ω/km/phase 1.47 2.42 0.93 1.54 0.67 1.11 0.490 0.820 0.340 0.570 0.250 0.410 0.200 0.330 0.160 0.270 0.130 0.210 0.100 0.160 0.080 0.130 0.060 0.100 0.050 0.080 0.040 0.060 0.036 0.042 0.032 0.038 CU AL Ω/km/phase 1.474 2.46 0.934 1.542 0.676 1.113 0.517 0.836 0.371 0.586 0.282 0.433 0.236 0.350 0.204 0.294 0.177 0.244 0.153 0.200 0.139 0.173 0.129 0.151 0.120 0.135 0.112 0.122 0.039 0.045 0.034 0.04 AL kg/km 420.3 320.4 536.7 380.5 659.3 440.5 823.3 510.9 1046.1 608.7 1315.6 722.0 1646.9 897.0 1950.3 1013.0 2392.4 1236.3 2962.9 1463.1 3702.8 1828.1 4778.5 2279.0 5823.5 2699.1 7411.1 3474.3 9143.1 4144.0 11263.3 5014.5 Asym. Sym. Current, Current,in in 1sec 1sec CU AL kA 2.3 1.5 3.2 3.5 2.3 3.7 5 3.3 3.9 7.2 4.7 4.3 10.0 6.6 4.8 13.6 9.0 5.2 17.2 11.3 5.9 21.5 14.2 6.3 26.5 17.5 8.7 34.3 22.7 9.7 42.9 28.3 13.4 57.2 37.8 14.8 71.5 47.2 16.6 90.1 59.5 23.7 114.4 73.6 26.0 143 92 28.3 Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Current (I) Ground Air AL CU AL Amps 91 71 88 69 117 93 114 92 147 113 147 113 174 135 174 136 217 169 223 173 261 203 242 209 304 236 269 248 342 266 361 280 388 303 410 364 456 356 488 381 525 412 573 450 596 473 652 518 693 556 773 622 778 675 872 712 843 702 996 918 895 774 1081 963 CU Unarmoured XLPE Low Voltage Power Cable 0.6/1 kV, SABS 1507, 90ºC, PVC-FR Sheath. Conductor: Annealed Copper or Aluminium Compacted – Class 2 Insulation: LV-XLPE Phase Color Code: Red or Black Application: Used for reticulation and underground power supply. Outer sheath can also be stripped blue or white. 600/1000V - 1 Cores XLPE Unarmoured PHYSICAL PROPERTIES Insulation Cable Cond. Overall Screen Cable Mass Size Diam. Diameter Diam. mm2 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000 mm 4.8 6.1 7.1 8.2 9.9 11.7 13.4 14.6 16.4 18.8 21.4 24.3 27.3 31.0 35.1 39.1 mm 6.2 7.9 8.9 10.2 12.1 13.9 15.8 17.4 19.6 22.2 25.0 28.3 31.7 35.8 40.3 44.7 mm 9.4 11.1 12.1 13.8 15.7 17.5 19.4 21 23.2 26.2 29.0 32.3 36.1 40.2 45.1 50.0 CU AL kg/km 216 117 318 162 418 199 582 270 787 349 1033 439 1284 534 1582 644 1934 778 2494 994 3080 1205 4042 1542 5044 1919 6299 2363 7969 2970 9874 3625 ELECTRICAL PROPERTIES Drum DC Resistance AC Resistance length @ 20°C @ 90°C m 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 CU AL Ω/km/phase 1.15 1.91 0.73 1.20 0.52 0.87 0.39 0.64 0.27 0.44 0.19 0.32 0.15 0.25 0.12 0.21 0.10 0.16 0.08 0.13 0.06 0.10 0.05 0.08 0.04 0.06 0.03 0.05 0.02 0.03 0.02 0.03 CU AL Ω/km/phase 1.47 2.420 0.93 1.540 0.67 1.110 0.49 0.820 0.34 0.570 0.25 0.410 0.2 0.330 0.16 0.270 0.13 0.210 0.1 0.160 0.08 0.130 0.06 0.100 0.05 0.080 0.04 0.060 0.04 0.042 0.03 0.038 Impedance CU AL Ω/km/phase 1.47 2.460 0.93 1.542 0.68 1.11 0.52 0.84 0.37 0.59 0.28 0.43 0.24 0.350 0.2 0.29 0.18 0.24 0.15 0.200 0.14 0.17 0.13 0.15 0.120 0.14 0.11 0.12 0.039 0.045 0.034 0.040 Sym. Current, in 1sec CU AL kA 2.3 3.5 5.0 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 57.2 71.5 90.1 114.4 143.0 1.5 2.3 3.3 4.7 6.6 9.0 11.3 14.2 17.5 22.7 28.3 37.8 47.2 59.5 73.6 92.0 Current (I) in Trefoil Ground Air CU AL CU AL Amps 91 71 88 69 117 93 114 92 147 113 147 113 174 135 174 136 217 169 223 173 261 203 242 209 304 236 269 248 342 266 361 280 388 303 410 364 456 356 488 381 525 412 573 450 596 473 652 518 693 556 773 622 778 675 872 712 843 702 996 918 895 774 1081 963 Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Unarmoured XLPE Low Voltage Power Cable 1.9/3.3 kV, SABS 1507, 90ºC, PVC-FR Sheath. Conductor: Annealed Copper or Aluminium Compacted – Class 2 Insulation: LV-XLPE Phase Color Code: Red or Black Application: Used for reticulation and underground power supply. Outer sheath can be stripped blue or white. 1900/3300V - 1 Cores XLPE Unarmoured PHYSICAL PROPERTIES Cable Cond. Insulation Overall Screen Cable Mass Size Diam. Diameter Diam. mm2 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000 mm 4.8 6.1 7.1 8.2 9.9 11.7 13.4 14.6 16.4 18.8 21.4 24.3 27.3 31.0 35.1 39.1 mm 8.8 10.1 11.1 12.2 13.9 15.7 17.4 18.6 20.4 22.8 25.4 28.3 31.7 35.8 40.3 44.7 mm 12 13.7 14.7 15.8 17.5 19.3 21.0 22.2 24.4 26.8 29.4 32.3 36.1 40.2 45.1 49.5 CU AL kg/km 265 165 377 221 481 263 632 320 837 399 1087 494 1337 587 1624 686 1988 832 2519 1019 3098 1224 4042 1542 5044 1919 6299 2363 7969 2970 9874 3625 ELECTRICAL PROPERTIES Drum DC Resistance AC Resistance length @ 20°C @ 90°C m 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 CU AL Ω/km/phase 1.15 1.91 0.727 1.2 0.524 0.87 0.387 0.640 0.268 0.440 0.193 0.320 0.153 0.250 0.124 0.210 0.099 0.160 0.075 0.130 0.060 0.100 0.047 0.080 0.037 0.060 0.028 0.050 0.021 0.033 0.019 0.032 CU AL Ω/km/phase 1.47 2.42 0.93 1.54 0.67 1.11 0.490 0.820 0.340 0.570 0.250 0.410 0.200 0.330 0.160 0.270 0.130 0.210 0.100 0.160 0.080 0.130 0.060 0.100 0.050 0.080 0.040 0.060 0.036 0.042 0.032 0.038 Impedance CU AL Ω/km/phase 1.474 2.46 0.934 1.542 0.676 1.113 0.517 0.836 0.371 0.586 0.282 0.433 0.236 0.350 0.204 0.294 0.177 0.244 0.153 0.200 0.139 0.173 0.129 0.151 0.120 0.135 0.112 0.122 0.039 0.045 0.034 0.04 Sym. Current, in 1sec CU AL kA 2.3 3.5 5.0 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 57.2 71.5 90.1 114.4 143.0 1.5 2.3 3.3 4.7 6.6 9.0 11.3 14.2 17.5 22.7 28.3 37.8 47.2 59.5 73.6 92.0 Current (I) Ground Air CU AL CU AL Amps 91 71 88 69 117 93 114 92 147 113 147 113 174 135 174 136 217 169 223 173 261 203 242 209 304 236 269 248 342 266 361 280 388 303 410 364 456 356 488 381 525 412 573 450 596 473 652 518 693 556 773 622 778 675 872 712 843 702 996 918 895 774 1081 963 Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Armoured XLPE Low Voltage Power Cable 0.6/1 kV, SABS 1507, 90ºC, PVC-FR Sheath Conductor: Annealed Copper or Aluminium Compacted – Class 2 Insulation: LV-XLPE Phase Color Code: Red, Yellow, Blue or Black Application: Used for reticulation and underground power supply. Outer sheath can also be stripped blue or white. 600/1000V - 2,3 & 4 Cores XLPE SWA Armoured PHYSICAL PROPERTIES Cable Cond. Insul. Size Diam. Diam. mm2 1 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 mm 1.19 1.46 1.86 2.35 2.89 3.74 4.72 4.1 4.9 5.5 6.4 11.6 12.5 14.5 16.0 18.5 mm 2.59 2.86 3.26 3.75 4.29 5.15 6.12 5.87 6.67 7.5 8.6 12.7 13.0 14.6 17.7 20.2 Overall Diameter 2C mm 12.0 12.5 13.3 14.3 15.4 17.1 19.3 21.7 23.3 24.9 27.0 - 3C mm 12.4 12.9 13.8 14.9 16 18.1 20.2 24.9 26.1 28.7 31.9 39.0 39.7 43.5 52.0 57.9 4C mm 13.1 13.7 14.7 15.9 17.1 19.4 22.8 27.5 30.1 33.0 38.8 44.8 49.9 56.0 60.6 67.9 DC Drum Resistance Cable Mass (kg/km) length @ 20°C 2C 3C 4C CU AL CU AL CU AL CU AL m Ω/km/phase 270 293 322 500 18.20 298 325 360 500 13.60 343 379 423 500 7.410 401 450 514 500 4.610 474 540 628 500 3.080 607 714 845 500 1.830 787 939 1189 500 1.150 1227 930 1608 1162 1960 1365 500 0.727 1.250 1469 1055 1908 1288 2416 1589 500 0.524 0.868 1760 1198 2371 1528 3002 1877 500 0.387 0.641 2223 1412 3071 1856 4286 2663 500 0.268 0.443 - 4371 2679 5553 3297 300 0.193 0.320 - 5050 2918 7178 4334 300 0.153 0.253 - 6053 3416 8642 5126 300 0.124 0.164 - 7974 4679 10106 5714 300 0.099 0.125 - 9903 5571 12419 6642 300 0.075 0.100 ELECTRICAL PROPERTIES AC Sym. Asym. Resistance @ Impedance Current Current 90°C CU AL CU AL CU AL 2C 3C 4C Ω/km/phase Ω/km/phase kA(1sec) 19.150 19.200 0.1 - 0.7 0.8 0.8 14.400 14.433 0.2 - 0.8 0.8 0.9 8.600 8.660 0.4 - 0.8 0.9 1 5.400 5.485 0.6 1 1 1.1 3.600 3.695 0.9 - 1.1 1.1 1.2 2.100 2.193 1.4 - 1.2 1.3 1.4 1.470 1.385 2.3 - 1.4 1.5 1.7 0.930 1.540 0.528 1.542 3.5 2.3 2.8 3.3 3.7 0.670 1.110 0.675 1.120 5.0 3.3 3 3.5 4.1 0.490 0.820 0.501 0.825 7.2 4.7 3.3 3.9 4.6 0.340 0.570 0.352 0.572 10.0 6.6 3.6 4.4 6.9 0.250 0.410 0.260 0.416 13.6 9.0 - 6.8 8 0.200 0.330 0.211 0.331 17.2 11.3 - 6.9 11 0.160 0.270 0.177 0.220 21.5 14.2 - 7.7 12.5 0.130 0.210 0.150 0.173 26.5 17.5 - 11 12.7 0.100 0.160 0.125 0.144 34.3 22.7 - 13 12.8 Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Current (I) Ground Air CU AL CU Amps 14 - 15 18 - 19 24 - 25 32 - 34 41 - 43 57 - 65 103 - 101 132 101 126 158 121 155 186 142 189 229 175 241 275 210 297 312 239 347 351 268 398 397 305 460 459 353 547 AL 95 116 142 180 223 260 298 346 412 Armoured PVC Low Voltage Power Cable 0.6/1 kV, SABS 1507, 70ºC, PVC-FR Sheath Conductor: Annealed Copper or Aluminium Compacted – Class 2 Insulation: PVC Phase Color Code: Red, Yellow , Blue and Black Application: Used for reticulation and underground power supply. Outer sheath can also be stripped blue or white. 600/1000V - 2,3 & 4 Cores PVC SWA Armoured PHYSICAL PROPERTIES Cable Cond. Insul. Overall Diameter Size Diam. Diam. mm2 1 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 mm 1.19 1.46 1.86 2.35 2.89 3.74 4.72 4.1 4.9 5.5 6.4 11.6 12.5 14.5 16.0 18.5 mm 2.59 2.86 3.26 3.75 4.29 5.15 6.12 5.87 6.67 7.5 8.6 12.7 13.0 14.6 17.7 20.2 2C mm 12.0 12.5 13.3 14.3 15.4 17.1 19.3 21.7 23.3 24.9 27.0 - 3C mm 12.4 12.9 13.8 14.9 16 18.1 20.2 24.9 26.1 28.7 31.9 39.0 39.7 43.5 52.0 57.9 4C mm 13.1 13.7 14.7 15.9 17.1 19.4 22.8 27.5 30.1 33.0 38.8 44.8 49.9 56.0 60.6 67.9 DC Drum Cable Mass (kg/km) Resistance @ length 20°C 2C 3C 4C CU AL CU AL CU AL CU AL m Ω/km/phase 270 293 322 500 18.2 298 325 360 500 13.6 343 379 423 500 7.41 401 450 514 500 4.61 474 540 628 500 3.08 607 714 845 500 1.83 787 939 1189 500 1.15 1245 943 1632 1178 1988 1384 500 0.727 1.250 1491 1070 1937 1307 2451 1612 500 0.524 0.868 1786 1216 2406 1550 3046 1905 500 0.387 0.641 2255 1432 3118 1883 4349 2702 500 0.268 0.443 4437 2718 5635 3346 300 0.193 0.320 5125 2961 7286 4399 300 0.153 0.253 6143 3466 8771 5203 300 0.124 0.164 8093 4749 10257 5799 300 0.099 0.125 10052 5654 12604 6741 300 0.075 0.100 ELECTRICAL PROPERTIES AC Resistance @ 70°C Impedance CU AL Ω/km/phase 19.150 14.430 8.660 5.480 3.700 2.190 1.380 1.500 2.500 1.100 1.800 0.800 1.350 0.550 0.900 0.410 0.670 0.330 0.530 0.260 0.420 0.210 0.340 0.165 0.260 CU AL Ω/km/phase 19.15 14.43 8.66 5.48 3.70 2.19 1.38 1.50 2.50 1.10 1.80 0.81 1.35 0.57 0.92 0.43 0.68 0.35 0.55 0.29 0.44 0.25 0.37 0.21 0.35 Sym. Current CU 0.1 0.2 0.3 0.5 0.7 1.2 1.8 2.9 4.0 5.8 8.1 10.9 13.8 17.3 21.3 27.8 Asym. Current AL 2C 3C kA(1sec) 0.7 0.8 0.8 0.8 0.8 0.9 1 1 1.1 1.1 1.2 1.3 1.4 1.5 1.9 2.8 3.3 2.7 3 3.5 3.8 3.3 3.9 5.3 3.6 4.4 7.2 - 6.8 9.1 - 6.9 11.4 - 7.7 14.1 - 11.4 18.2 - 12.7 Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Current (I) Ground 4C CU 0.8 0.9 1 1.1 1.2 1.4 1.7 3.7 4.1 4.6 6.9 8 11 12.5 12.7 12.8 15 18 25 32 41 57 91 119 143 169 210 251 285 320 361 416 Air AL CU Amps 14 17 24 33 42 60 80 93 101 112 126 133 153 165 196 197 238 225 276 252 319 286 364 331 430 AL 84 102 122 154 189 219 249 287 339 Unarmoured PVC Low Voltage Power Cable 0.6/1 kV, SABS 1507, 70ºC, PVC-FR Sheath Conductor: Annealed Copper or Aluminium Compacted – Class 2 Insulation: PVC Phase Color Code: Red, Yellow, Blue or Black Application: Used for reticulation and underground power supply. Outer sheath can also be stripped blue or white. 600/1000V - 2,3 & 4 Cores PVC Unarmoured PHYSICAL PROPERTIES Cable Cond. Insul. Size Diam. Diam. mm2 1 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 mm 1.19 1.46 1.86 2.35 2.89 3.74 4.72 4.1 4.9 5.5 6.4 11.6 12.5 14.5 16.0 18.5 mm 2.59 2.86 3.26 3.75 4.29 5.15 6.12 5.87 6.67 7.5 8.6 12.7 13 14.6 17.7 20.2 Overall Diameter 2C mm 8.9 9.4 10.2 11.2 12.3 14.4 16.3 15.8 17.4 19.1 21.2 - 3C mm 9.2 9.7 10.6 11.6 12.8 14.9 17.0 18.8 19.9 22.3 25.9 31.3 31.9 35.7 42.2 48.0 Cable Mass (kg/km) 4C 2C mm CU AL 9.4 82 10.1 97 11.1 124 12.3 162 13.9 209 16.0 315 18.3 447 21.2 612 282 23.6 815 351 26.9 1114 438 31.5 1512 577 37.5 40.3 46.5 51.5 58.4 - 3C CU 98 118 155 208 276 421 612 892 1183 1634 2262 3033 3742 4680 5785 7464 4C AL CU 118 143 191 261 363 537 787 398 1169 487 1570 619 2198 859 3115 1143 4062 1357 5045 1678 6331 2108 7799 2715 10044 AL 509 642 845 1141 1543 1864 2328 2896 3712 DC Drum Resistance @ length 20°C CU AL m Ω/km/phase 500 18.2 500 13.6 500 7.41 500 4.61 500 3.08 500 1.83 500 1.15 500 0.727 1.250 500 0.524 0.868 500 0.387 0.641 500 0.268 0.443 300 0.193 0.320 300 0.153 0.253 300 0.124 0.164 300 0.099 0.125 300 0.075 0.100 AC Resistance @ 90°C Impedance CU AL Ω/km/phase 19.15 14.43 8.66 5.48 3.7 2.19 1.38 1.500 2.500 1.100 1.800 0.800 1.350 0.550 0.900 0.410 0.670 0.330 0.530 0.260 0.420 0.210 0.340 0.165 0.260 CU AL Ω/km/phase 19.2 14.4 8.66 5.48 3.7 2.19 1.38 1.500 2.500 1.100 1.800 0.810 1.350 0.570 0.920 0.430 0.680 0.350 0.550 0.290 0.440 0.250 0.370 0.210 0.350 Sym. Current CU 0.1 0.2 0.3 0.5 0.7 1.2 1.8 2.9 4.0 5.8 8.1 10.9 13.8 17.3 21.3 27.8 Current (I) AL CU AL kA(1sec) 15 18 25 32 41 57 91 1.9 119 93 2.7 143 112 3.8 169 133 5.3 210 165 7.2 251 197 9.1 285 225 11.4 320 252 14.1 361 286 18.2 416 331 Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Current (I) Ground CU AL 14 17 24 33 42 60 80 101 126 153 196 238 276 319 364 430 84 102 122 154 189 219 249 287 339 Air AL CU Amps 14 17 24 33 42 60 80 93 101 112 126 133 153 165 196 197 238 225 276 252 319 286 364 331 430 AL 84 102 122 154 189 219 249 287 339 Unarmoured XLPE Low Voltage Power Cable 0.6/1 kV, SABS 1507, 90ºC, PVC-FR Sheath Conductor: Annealed Copper or Aluminium Compacted – Class 2 Insulation: LV-XLPE Phase Color Code: Red, Yellow, Blue or Black Application: Used for reticulation and underground power supply. Outer sheath can also be stripped blue or white. 600/1000V - 2,3 & 4 Cores XLPE Unarmoured PHYSICAL PROPERTIES Cable Cond. Insul. Overall Diameter Size Diam. Diam. mm2 1 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 mm 1.19 1.46 1.86 2.35 2.89 3.74 4.72 4.1 4.9 5.5 6.4 11.6 12.5 14.5 16.0 18.5 mm 2.59 2.86 3.26 3.75 4.29 5.15 6.12 5.87 6.67 7.5 8.6 12.7 13 14.6 17.7 20.2 2C mm 8.9 9.4 10.2 11.2 12.3 14.4 16.3 15.8 17.4 19.1 21.2 - 3C mm 9.2 9.7 10.6 11.6 12.8 14.9 17 18.8 19.9 22.3 25.9 31.3 31.9 35.7 42.2 48.0 4C mm 9.4 10.1 11.1 12.3 13.9 16 18.3 21.2 23.6 26.9 31.5 37.5 40.3 46.5 51.5 58.4 DC Drum Cable Mass (kg/km) Resistance @ length 20°C 2C 3C 4C CU AL CU AL CU AL CU AL m Ω/km/phase 80.3 95.5 114.64 500 18.2 94.6 114.9 139.67 500 13.6 120.6 151.1 186.57 500 7.41 157.6 203.0 254.19 500 4.61 204.2 269.1 354.39 500 3.08 306.9 410.7 523.47 500 1.83 436.3 597.0 768.27 500 1.15 597.3 275.6 870.4 387.8 1140.0 496.5 500 0.727 1.250 795.6 342.9 1153.8 474.8 1531.3 626.0 500 0.524 0.868 1087.1 427.3 1593.8 604.2 2144.4 824.8 500 0.387 0.641 1475.5 563.0 2206.7 838.0 2941.4 1113.4 500 0.268 0.443 2958.9 1115.4 3962.9 1504.9 300 0.193 0.320 3651.1 1323.7 4921.4 1818.2 300 0.153 0.253 4565.8 1636.7 6176.7 2271.3 300 0.124 0.164 5643.7 2056.5 7608.8 2825.8 300 0.099 0.125 7282.4 2649.2 9799.1 3621.6 300 0.075 0.100 ELECTRICAL PROPERTIES AC Resistance @ 90°C CU AL Ω/km/phase 19.15 14.4 8.6 5.4 3.6 2.1 1.47 0.930 1.540 0.670 1.110 0.490 0.820 0.340 0.570 0.250 0.410 0.200 0.330 0.160 0.270 0.130 0.210 0.100 0.160 Impedance CU AL Ω/km/phase 19.20 14.43 8.66 5.485 3.695 2.193 1.385 0.528 1.542 0.675 1.120 0.501 0.825 0.352 0.572 0.260 0.416 0.211 0.331 0.177 0.220 0.150 0.173 0.125 0.144 Sym. Current CU 0.1 0.2 0.4 0.6 0.9 1.4 2.3 3.5 5.0 7.2 10.0 13.6 17.2 21.5 26.5 34.3 AL CU AL kA(1sec) 14 18 24 32 41 57 - 103 2.3 132 101 3.3 158 121 4.7 186 142 6.6 229 175 9.0 275 210 11.3 312 239 14.2 351 268 17.5 397 305 22.7 459 353 Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Current (I) Current (I) Ground CU AL 15 19 25 34 43 65 101 126 155 189 241 297 347 398 460 547 95 116 142 180 223 260 298 346 412 Air AL CU Amps 14 17 24 33 42 60 80 93 101 112 126 133 153 165 196 197 238 225 276 252 319 286 364 331 430 AL 84 102 122 154 189 219 249 287 339 Armoured XLPE Low Voltage Power Cable 1.9/3.3 kV, SABS 1507, 90ºC, PVC-FR Sheath. Conductor: Annealed Copper or Aluminium Compacted – Class 2 Insulation: LV-XLPE Phase Color Code: Red, Yellow, Blue Application: Used for reticulation and underground power supply. Outer sheath can also be stripped blue or white. 1900/3300V - 3 Cores XLPE AWA PHYSICAL PROPERTIES Insulation Cable Core Overall Screen Diameter Cable Mass Size Diam. Diam. mm2 10 16 25 35 50 70 95 120 150 185 240 mm 3.8 4.7 5.2 5.7 6.6 7.9 10.5 10.6 11.8 14.5 16.8 mm 7.8 8.7 9.2 9.7 10.6 11.9 14.5 14.6 15.8 18.5 20.8 mm 26.1 28.1 29.1 30.6 32.5 36.9 42.7 42.9 45.8 53.3 58.7 CU AL kg/km 1355 1636 1939 1835 2307 2151 2831 2549 3883 3539 4977 4555 5684 5153 6730 6006 8685 7870 10665 9671 ELECTRICAL PROPERTIES Drum DC Resistance AC Resistance length @ 20°C @ 90°C m 500 500 500 500 500 500 500 500 500 500 500 CU AL Ω/km/phase 1.15 0.727 0.524 0.87 0.387 0.640 0.268 0.440 0.193 0.320 0.153 0.250 0.124 0.210 0.099 0.160 0.075 0.130 0.060 0.100 CU AL Ω/km/phase 1.47 0.93 0.67 1.11 0.490 0.820 0.340 0.570 0.250 0.410 0.200 0.330 0.160 0.270 0.130 0.210 0.100 0.160 0.080 0.130 Impedance CU AL Ω/km/phase 1.474 0.934 0.676 1.113 0.517 0.836 0.371 0.586 0.282 0.433 0.236 0.350 0.204 0.294 0.177 0.244 0.153 0.200 0.139 0.173 Asym. Sym. Current, Current,in in 1sec 1sec CU AL kA 2.3 4.1 3.5 4.6 5 3.3 4.8 7.2 4.7 5.0 10.0 6.6 5.4 13.6 9.0 7.6 17.2 11.3 8.9 21.5 14.2 9.1 26.5 17.5 9.7 34.3 22.7 14.2 42.9 28.3 15.9 Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Current (I) Ground Air CU AL CU AL Amps 91 88 117 114 147 113 147 113 174 135 174 136 217 169 223 173 261 203 242 209 304 236 269 248 342 266 361 280 388 303 410 364 456 356 488 381 525 412 573 450 Unarmoured XLPE Low Voltage Power Cable 1.9/3.3 kV, SABS 1507, 90ºC, PVC-FR Sheath. Conductor: Annealed Copper or Aluminium Compacted – Class 2 Insulation: LV-XLPE Phase Color Code: Red, Yellow, Blue Application: Used for reticulation and underground power supply . Outer sheath can also be stripped blue or white. 1900/3300V - 3 Cores XLPE Unarmoured PHYSICAL PROPERTIES Cable Cond. Insulation Overall Cable Mass Size Diam. Diam. Diameter CU AL mm mm mm kg/km mm2 10 3.8 7.7 20 580 16 4.7 8.7 22 781 25 5.2 9.2 23 1048 944 35 5.7 9.7 25 1376 1220 50 6.6 10.6 26 1826 1544 70 7.9 11.9 29 2430 2087 95 10.5 14.5 35 3266 2844 120 10.6 14.6 36 3961 3431 150 11.8 15.8 38 4840 4116 185 14.5 18.5 43 5918 5103 240 16.8 20.8 49.0 7594 6600 Drum DC Resistance AC Resistance length @ 20°C @ 90°C CU AL CU AL m Ω/km/phase Ω/km/phase 500 1.15 1.47 500 0.73 0.93 500 0.52 0.87 0.67 1.110 500 0.39 0.64 0.49 0.820 500 0.27 0.44 0.34 0.570 500 0.19 0.32 0.25 0.410 500 0.15 0.25 0.2 0.330 500 0.12 0.21 0.16 0.270 500 0.10 0.16 0.13 0.210 500 0.08 0.13 0.1 0.160 500 0.06 0.10 0.08 0.130 ELECTRICAL PROPERTIES Sym. Current, Impedance in 1sec CU AL CU AL Ω/km/phase kA 1.47 2.3 0.93 3.5 0.68 1.11 5.0 3.3 0.52 0.84 7.2 4.7 0.37 0.59 10.0 6.6 0.28 0.43 13.6 9.0 0.24 0.350 17.2 11.3 0.2 0.29 21.5 14.2 0.18 0.24 26.5 17.5 0.15 0.200 34.3 22.7 0.14 0.17 42.9 28.3 Current (I) Ground Air CU AL CU AL Amps 91 88 117 114 147 113 147 113 174 135 174 136 217 169 223 173 261 203 242 209 304 236 269 248 342 266 361 280 388 303 410 364 456 356 488 381 525 412 573 450 Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Armoured Multi-Core Low Voltage Power Cable 0.6/1 kV, SABS 1507, 90ºC, PVC-FR Sheath Conductor: Annealed Stranded Copper – Class 2 Insulation: LV-XLPE Phase Identification: Numbers Application: Used to power control circuits like robots, etc. Outer sheath can also be stripped blue or white . 600/1000V 7-37 Cores Armoured PHYSICAL PROPERTIES Cable Size mm2 1 1.5 2.5 4 6 No. of Cores Core Diam. Insulation Diam. 7 12 19 27 37 7 12 19 27 37 7 12 19 27 37 7 12 19 27 37 7 mm 1.19 1.19 1.19 1.19 1.19 1.46 1.46 1.46 1.46 1.46 1.86 1.86 1.86 1.86 1.86 2.35 2.35 2.35 2.35 2.35 2.89 mm 2.59 2.59 2.59 2.59 2.59 2.86 2.86 2.86 2.86 2.86 3.26 3.26 3.26 3.26 3.26 3.75 3.75 3.75 3.75 3.75 4.29 Overall Diameter Cable Mass mm 15.5 20.7 21.7 27.0 28.9 17.0 21.2 25.9 29.8 32.8 18.5 24.8 28.1 32.6 37.6 21.0 28.2 32.5 39.8 43.8 24.4 kg/km 300 480 700 960 1380 629 901 1404 1783 2153 756 1306 1695 2181 3011 986 1211 2282 3354 4124 1412 Drum length m 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 ELECTRICAL PROPERTIES DC AC Sym. Resistance Resistance Impedance Current, in @ 20°C @ 90°C 1sec Ω/km/phase Ω/km/phase Ω/km/phase kA 18.2 19.15 19.15 0.1 18.2 19.15 19.15 0.1 18.2 19.15 19.15 0.1 18.2 19.15 19.15 0.1 18.2 19.15 19.15 0.1 13.6 14.43 14.47 0.2 13.6 14.43 14.47 0.2 13.6 14.43 14.47 0.2 13.6 14.430 14.47 0.2 13.6 14.430 14.47 0.2 7.41 8.66 8.86 0.3 7.41 8.66 8.86 0.3 7.41 8.66 8.86 0.3 7.41 8.66 8.86 0.3 7.41 8.66 8.86 0.3 4.61 5.48 5.51 0.5 4.61 5.48 5.51 0.5 4.61 5.48 5.51 0.5 4.61 5.48 5.51 0.5 4.61 5.48 5.51 0.5 3.08 3.68 3.7 0.7 Current (I) Ground Amps 15 14 13 12 11 18 15 12 11 9 24 19 16 14 12 31 25 21 18 16 38 Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Air 14 13 12 11 10 15 12 11 10 8 20 17 14 13 11 26 22 19 17 15 33 Unarmoured Multi-Core Low Voltage Power Cable 0.6/1 kV, SABS 1507, 90ºC, PVC-FR Sheath Conductor: Annealed Stranded Copper – Class 2 Insulation: LV-XLPE Phase Identification: Numbers Application: Used to power control circuits like robots, etc. Outer sheath can be stripped red, blue or white . 600/1000V 7-37 Cores Unarmoured PHYSICAL PROPERTIES Cable Size mm2 1 1.5 2.5 4 6 No. of Cores Core Diam. Insulation Diam. 7 12 19 27 37 7 12 19 27 37 7 12 19 27 37 7 12 19 27 37 7 mm 1.19 1.19 1.19 1.19 1.19 1.46 1.46 1.46 1.46 1.46 1.86 1.86 1.86 1.86 1.86 2.35 2.35 2.35 2.35 2.35 2.89 mm 2.59 2.59 2.59 2.59 2.59 2.86 2.86 2.86 2.86 2.86 3.26 3.26 3.26 3.26 3.26 3.75 3.75 3.75 3.75 3.75 4.29 Overall Diameter Cable Mass mm 10 12.9 14.9 17.9 21.2 11.4 15.0 16.9 21.1 22.7 13.3 17.5 21 24.8 27.9 15.4 17.3 22.9 27.1 30.8 17 kg/km 150 240 350 480 690 195 320 450 670 840 300 490 760 1030 1380 493 606 1141 1677 2062 707 Drum length m 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 ELECTRICAL PROPERTIES DC AC Sym. Resistance Resistance Impedance Current, in @ 20°C @ 90°C 1sec Ω/km/phase Ω/km/phase Ω/km/phase kA 18.2 19.15 19.15 0.1 18.2 19.15 19.15 0.1 18.2 19.15 19.15 0.1 18.2 19.15 19.15 0.1 18.2 19.15 19.15 0.1 13.6 14.43 14.47 0.2 13.6 14.43 14.47 0.2 13.6 14.43 14.47 0.2 13.6 14.43 14.47 0.2 13.6 14.43 14.47 0.2 7.41 8.66 8.86 0.3 7.41 8.66 8.86 0.3 7.41 8.66 8.86 0.3 7.41 8.66 8.86 0.3 7.41 8.66 8.86 0.3 4.61 5.48 5.51 0.5 4.61 5.48 5.51 0.5 4.61 5.48 5.51 0.5 4.61 5.48 5.51 0.5 4.61 5.48 5.51 0.5 3.08 3.68 3.7 0.7 Current (I) Ground Amps 15 14 13 12 11 18 15 12 11 9 24 19 16 14 12 31 25 21 18 16 38 Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Air 14 13 12 11 10 15 12 11 10 8 20 17 14 13 11 26 22 19 17 15 33 Aerial Bundle Conductor (LV-ABC) Low Voltage XLPE Power Cable , SABS 1418, 600/1000V (ABC XLPE Insulated + Insulated Support) Conductor: Aluminium Compacted Circular- Class 2 Phase Color Identification: Numbered, 1, 2 & 3 + Insulated Support Application: Used for aerial reticulation (sometimes with street lighting core) LV ABC - 600/1000V Cable Size Conductor Diameter mm2 mm 25 6.5 35 7.3 50 8.3 70 10.2 95 12.3 120 13.5 150 15.3 PHYSICAL PROPERTIES Insulation Support Overall Diameter Core Size Diameter mm mm2 mm 9.5 54.6 22.9 10.5 54.6 25.3 11.7 54.6 28.1 13.6 54.6 32.8 15.9 54.6 38.2 17.1 70 41.2 19.3 95 46.5 Cable mass kg/km 420 555 752 1012 1348 1651 2065 Drum length m 500 500 500 500 500 500 500 Res. DC @ 20°C Ω/km 1.200 0.868 0.641 0.443 0.320 0.253 0.206 ELECTRICAL PROPERTIES Res. AC @ Impedance Symmetrical Current 90°C Current Rating in Air Ω/km Ω/km kA Amps 1.54 1.541 2.3 105 1.11 1.117 3.3 130 0.82 0.826 4.7 165 0.57 0.574 6.6 205 0.41 0.419 9 250 0.33 0.334 11.3 290 0.27 0.276 14.2 320 Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Armoured Medium Voltage (MV) XLPE Type A, Single Core, Power Cable , SANS 1339 Conductor: Annealed Copper or Aluminium Circular Compacted - Class 2 Application: Used for underground reticulation, main distribution system, sub-station and mining. Can be manufactured with corrugated aluminium or steel tape. Outer-sheath can also be stripped blue or white according to customer requirements. 3.8/6.6kV - 1 Cores AWA PHYSICAL PROPERTIES Insulation Cable Core Overall Cable Mass Drum Screen Size Diam. Diameter length Diam. CU AL mm mm mm kg/km m mm2 50 8.4 16.7 26.7 1252 943 500 70 9.9 18.2 28.2 1495 1062 500 95 11.7 20.0 30.2 1810 1223 500 120 13.4 21.7 31.9 2107 1365 500 150 14.6 22.9 33.3 2443 1515 500 185 16.4 24.7 35.9 2927 1782 500 240 18.8 27.3 38.7 3563 2079 500 300 21.4 30.3 41.9 4276 2420 500 400 24.3 33.6 45.4 5365 2890 500 500 27.3 37.5 50.9 6724 3630 300 630 31.0 41.2 55.0 8143 4246 300 6.35/11kV 1 Cores AWA 50 8.4 18.5 28.6 1359 1049 500 70 9.9 20.0 30.3 1621 1188 500 95 11.7 21.8 32.1 1927 1339 500 120 13.4 23.5 34.0 2246 1503 500 150 14.6 24.7 36.2 2680 1752 500 185 16.4 26.5 38.0 3081 1937 500 240 18.8 28.9 40.6 3712 2227 500 300 21.4 31.5 43.2 4377 2521 500 400 24.3 34.4 46.5 5460 2986 500 500 27.3 37.9 51.4 6764 3670 300 630 31.0 41.6 55.5 8187 4289 300 Resistance @ Resistance @ 20°C 90°C Impedance CU AL Ω/km/phase 0.387 0.641 0.268 0.443 0.193 0.320 0.153 0.253 0.124 0.206 0.099 0.164 0.075 0.125 0.060 0.100 0.047 0.077 0.037 0.061 0.028 0.047 CU AL Ω/km/phase 0.494 0.822 0.342 0.568 0.247 0.411 0.196 0.325 0.159 0.265 0.128 0.211 0.098 0.161 0.079 0.130 0.063 0.102 0.051 0.080 0.041 0.064 CU AL Ω/km/phase 0.513 0.834 0.366 0.583 0.275 0.429 0.229 0.346 0.196 0.288 0.170 0.239 0.146 0.194 0.131 0.167 0.121 0.145 0.115 0.130 0.107 0.118 0.387 0.268 0.193 0.153 0.124 0.099 0.075 0.06 0.047 0.037 0.028 0.494 0.342 0.247 0.196 0.159 0.128 0.098 0.079 0.063 0.051 0.041 0.513 0.366 0.275 0.229 0.196 0.170 0.146 0.131 0.121 0.115 0.107 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.077 0.061 0.047 0.82 0.57 0.41 0.33 0.27 0.21 0.16 0.13 0.1 0.08 0.06 0.834 0.583 0.429 0.346 0.288 0.239 0.194 0.167 0.145 0.130 0.118 ELECTRICAL PROPERTIES Sym. Asym. Current, in Current,in Capacitance 1sec 1sec CU AL uf/km/phase kA 7.2 4.7 9.0 323.754 10.0 6.6 9.6 363.980 13.6 9.0 10.4 412.112 17.2 11.3 11.1 457.470 21.5 14.2 11.6 489.445 26.5 17.5 15.4 537.356 34.3 22.7 16.7 580.516 42.9 28.3 18.3 605.340 57.2 37.8 20.1 633.487 71.5 47.2 27.6 670.139 90.0 59.5 30.1 746.857 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 57.2 71.5 90.0 4.7 6.6 9.0 11.3 14.2 17.5 22.7 28.3 37.8 47.2 59.5 9.7 10.4 11.1 12 15.3 16.3 17.7 19.1 20.5 27.8 30.5 Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. 253.773 283.609 319.249 352.793 376.419 411.798 458.882 509.806 566.532 634.529 706.761 Current (I) Ground CU AL 206 250 298 336 373 411 468 522 580 618 669 206 250 297 334 370 412 470 520 579 620 672 Air Duct CU AL 161 195 233 264 294 328 376 422 476 522 576 CU AL Amps 239 186 295 230 358 280 412 324 464 365 520 414 605 485 690 557 784 641 860 722 949 814 165 200 238 269 298 329 374 418 464 494 535 129 156 186 211 235 262 301 338 381 418 461 161 195 233 263 292 328 377 421 476 523 579 242 297 361 412 464 524 611 688 783 864 957 165 200 238 267 296 330 376 416 463 496 538 129 156 186 210 234 262 302 337 381 418 463 188 232 283 324 366 416 489 555 640 724 819 Armoured Medium Voltage (MV) XLPE Type A, Single Core, Power Cable , SANS 1339 Conductor: Annealed Copper or Aluminium Circular Compacted - Class 2 Application: Used for underground reticulation, main distribution system, sub-station and mining. Can be manufactured with corrugated aluminium or steel tape. Outer-sheath can also be stripped blue or white according to customer requirements. 12.7/22kV - 1 Cores AWA PHYSICAL PROPERTIES Insulation Cable Core Overall Cable Mass Drum Resistance @ Resistance @ Screen Size Diam. Diameter length 20°C 90°C Diam. mm mm mm2 50 8.4 23.0 70 9.9 24.5 95 11.7 26.3 120 13.4 28.0 150 14.6 29.2 185 16.4 31.0 240 18.8 33.4 300 21.4 36.0 400 24.3 38.9 500 27.3 42.4 630 31 46.1 19/33kV 1 Cores AWA 50 8.4 28.2 70 9.9 29.7 95 11.7 31.5 120 13.4 33.2 150 14.6 34.4 185 16.4 36.2 240 18.8 38.6 300 21.4 41.2 400 24.3 44.1 500 27.3 47.6 630 31 51.3 mm CU AL kg/km m CU AL Ω/km/phase CU AL Ω/km/phase ELECTRICAL PROPERTIES Sym. Asym. Impedance Current, in Current,in Capacitance 1sec 1sec CU AL CU AL uf/km/phase Ω/km/phase kA Current (I) Ground Air Duct CU AL CU AL Amps CU AL 33.5 35.8 37.8 39.5 40.9 42.7 45.1 48.9 52.4 56.3 60.4 1668 2018 2361 2680 3036 3451 4101 4993 6089 7271 8727 1358 1585 1774 1938 2108 2306 2616 3137 3615 4178 4829 500 500 500 500 500 500 500 500 500 300 300 0.39 0.27 0.19 0.15 0.12 0.1 0.08 0.06 0.05 0.04 0.03 0.64 0.44 0.32 0.25 0.21 0.16 0.13 0.1 0.08 0.06 0.05 0.49 0.34 0.25 0.2 0.16 0.13 0.1 0.08 0.06 0.05 0.04 0.82 0.57 0.41 0.33 0.27 0.21 0.16 0.13 0.1 0.08 0.06 0.517 0.371 0.282 0.236 0.204 0.177 0.153 0.139 0.129 0.120 0.112 0.836 0.586 0.433 0.350 0.294 0.244 0.200 0.173 0.151 0.135 0.122 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 57.2 71.5 90.0 4.7 6.6 9.0 11.3 14.2 17.5 22.7 28.3 37.8 47.2 59.5 11.8 15.3 16.3 17 17.8 18.8 19.9 26.7 28.4 31 33.2 182.108 201.132 223.777 245.028 259.969 282.305 311.978 344.019 379.662 423.213 468.578 206 250 297 333 372 414 470 509 567 622 676 160 195 232 263 293 329 377 415 468 523 580 243 302 365 416 471 531 616 681 775 669 963 189 236 286 327 370 421 491 552 636 725 821 165 200 238 266 298 331 376 407 454 498 541 128 156 186 210 234 263 302 332 374 418 464 39.9 41.4 43.4 45.1 47.7 49.7 52.1 55.1 58.2 62.1 66.0 2169 2445 2806 3140 3687 4149 4807 5580 6705 7926 9387 1860 2011 2218 2397 2759 3004 3322 3724 4231 4832 5489 500 500 500 500 500 500 500 500 500 300 300 0.39 0.27 0.19 0.15 0.12 0.1 0.08 0.06 0.05 0.04 0.03 0.64 0.44 0.32 0.25 0.21 0.16 0.13 0.1 0.08 0.06 0.05 0.49 0.34 0.25 0.2 0.16 0.13 0.1 0.08 0.06 0.05 0.04 0.82 0.57 0.41 0.33 0.27 0.21 0.16 0.13 0.1 0.08 0.06 0.517 0.371 0.282 0.236 0.204 0.177 0.153 0.139 0.129 0.120 0.112 0.836 0.586 0.433 0.350 0.294 0.244 0.200 0.173 0.151 0.135 0.122 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 57.2 71.5 90.0 4.7 6.6 9.0 11.3 14.2 17.5 22.7 28.3 37.8 47.2 59.5 17.4 18.1 19.1 19.8 25.7 26.7 28.4 30 23.1 34.3 36.5 141.7481 155.2100 171.1653 186.0854 196.5494 212.1616 232.8540 255.1489 279.9040 309.9635 341.3560 206 250 297 333 372 414 470 509 567 622 676 160 195 232 263 293 329 377 415 468 523 580 243 302 365 416 471 531 616 681 775 669 963 189 236 286 327 370 421 491 552 636 725 821 165 200 238 266 298 331 376 407 454 498 541 128 156 186 210 234 263 302 332 374 418 464 Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Unarmoured Medium Voltage (MV) XLPE Type B, Single Core, Power Cable , SANS 1339 Conductor: Circular Annealed Copper or Aluminium Circular Compacted - Class 2 Application: Used for underground reticulation, main distribution system, sub-station and mining. Can be manufactured with corrugated aluminium or steel tape. Outer-sheath can also be stripped blue or white according to customer requirements. 3.8/6.6kV - 1 Cores AWA PHYSICAL PROPERTIES Insulation Cable Core Overall Drum Resistance @ Resistance @ Size Diam. Screen Diameter Cable Mass length 20°C 90°C Diam. mm mm mm2 mm 50 8.4 16.7 21.1 70 9.9 18.2 22.5 95 11.7 20.0 24.3 120 13.4 21.7 26.2 150 14.6 22.9 27.4 185 16.4 24.7 29.4 240 18.8 27.3 32.0 300 21.4 30.3 35.1 400 24.3 33.6 38.8 500 27.3 37.5 42.9 630 31.0 41.2 46.8 6.35/11kV 1 Cores Unarmoured 50 8.4 18.5 23.2 70 9.9 20.0 24.4 95 11.7 21.8 26.4 120 13.4 23.5 28.1 150 14.6 24.7 29.5 185 16.4 26.5 31.3 240 18.8 28.9 33.9 300 21.4 31.5 36.6 400 24.3 34.4 39.7 500 27.3 37.9 43.4 630 31.0 41.6 47.3 CU AL kg/km 953 644 1188 755 1469 881 1760 1017 2066 1138 2452 1307 3035 1550 3593 1742 4647 2172 5722 2628 7031 3134 1050 1278 1578 1861 2186 2562 3156 3697 4705 5753 7065 741 845 990 1119 1258 1418 1671 1841 2230 2660 3168 Impedance m 500 500 500 500 500 500 500 500 500 300 300 CU AL Ω/km/phase 0.387 0.641 0.268 0.443 0.193 0.320 0.153 0.253 0.124 0.206 0.099 0.164 0.075 0.125 0.060 0.100 0.047 0.077 0.037 0.061 0.028 0.047 CU AL Ω/km/phase 0.494 0.822 0.342 0.568 0.247 0.411 0.196 0.325 0.159 0.265 0.128 0.211 0.098 0.161 0.079 0.130 0.063 0.102 0.051 0.080 0.041 0.064 CU AL Ω/km/phase 0.513 0.834 0.366 0.583 0.275 0.429 0.229 0.346 0.196 0.288 0.170 0.239 0.146 0.194 0.131 0.167 0.121 0.145 0.115 0.130 0.107 0.118 500 500 500 500 500 500 500 500 500 300 300 0.387 0.268 0.193 0.153 0.124 0.099 0.075 0.06 0.047 0.037 0.028 0.494 0.342 0.247 0.196 0.159 0.128 0.098 0.079 0.063 0.051 0.041 0.513 0.366 0.275 0.229 0.196 0.170 0.146 0.131 0.121 0.115 0.107 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.077 0.061 0.047 0.82 0.57 0.41 0.33 0.27 0.21 0.16 0.13 0.1 0.08 0.06 0.834 0.583 0.429 0.346 0.288 0.239 0.194 0.167 0.145 0.130 0.118 ELECTRICAL PROPERTIES Sym. Asym. Current, in Current,in Capacitance 1sec 1sec CU uf/km/phase Current (I) Ground CU AL 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 57.2 71.5 90.0 AL kA 4.7 6.6 9.0 11.3 14.2 17.5 22.7 28.3 37.8 47.2 59.5 2.5 2.7 3.0 3.2 3.4 3.7 4.0 3.0 3.3 3.7 4.0 323.754 363.980 412.112 457.470 489.445 537.356 580.516 605.340 633.487 670.139 746.857 206 250 298 336 373 411 468 522 580 618 669 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 57.2 71.5 90.0 4.7 6.6 9.0 11.3 14.2 17.5 22.7 28.3 37.8 47.2 59.5 2.8 3.0 3.3 3.5 3.7 3.9 4.3 3.1 3.4 3.7 4.1 253.773 283.609 319.249 352.793 376.419 411.798 458.882 509.806 566.532 634.529 706.761 206 250 297 334 370 412 470 520 579 620 672 Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. 161 195 233 264 294 328 376 422 476 522 576 Air CU AL Amps 239 186 295 230 358 280 412 324 464 365 520 414 605 485 690 557 784 641 860 722 949 814 165 200 238 269 298 329 374 418 464 494 535 129 156 186 211 235 262 301 338 381 418 461 161 195 233 263 292 328 377 421 476 523 579 242 297 361 412 464 524 611 688 783 864 957 165 200 238 267 296 330 376 416 463 496 538 129 156 186 210 234 262 302 337 381 418 463 188 232 283 324 366 416 489 555 640 724 819 Duct CU AL Unarmoured Medium Voltage (MV) XLPE Type B, Single Core, Power Cable , SANS 1339 Conductor: Annealed Copper or Aluminium Circular Compacted - Class 2 Application: Used for underground reticulation, main distribution system, sub-station and mining. Can be manufactured with corrugated aluminium or steel tape. Outer-sheath can also be stripped blue or white according to customer requirements. 12.7/22kV - 1 Cores Unarmoured PHYSICAL PROPERTIES Insulation Cable Core Overall Drum Resistance @ Resistance @ Screen Size Diam. Diameter Cable Mass length 20°C 90°C Diam. mm mm mm2 50 8.4 23.2 70 9.9 24.7 95 11.7 26.5 120 13.4 28.2 150 14.6 29.4 185 16.4 31.2 240 18.8 33.6 300 21.4 36.2 400 24.3 39.1 500 27.3 42.5 630 31.0 46.2 19/33kV 1 Cores Unarmoured 50 8.4 28.4 70 9.9 29.9 95 11.7 31.7 120 13.4 33.4 150 14.6 34.6 185 16.4 36.4 240 18.8 38.8 300 21.4 41.4 400 24.3 44.3 500 27.3 47.8 630 31.0 51.5 mm 28.0 29.4 31.2 33.1 34.3 36.2 38.8 41.4 44.5 48.2 52.1 CU AL kg/km 1298 988 1551 1118 1852 1264 2164 1422 2483 1555 2786 1641 3393 1908 4034 2178 5066 2591 6142 3048 7484 3586 m 500 500 500 500 500 500 500 500 500 300 300 CU AL Ω/km/phase 0.39 0.64 0.27 0.44 0.19 0.32 0.15 0.25 0.12 0.21 0.1 0.16 0.08 0.13 0.06 0.1 0.05 0.08 0.04 0.06 0.03 0.05 33.5 34.7 36.7 38.4 39.8 41.6 44.2 47.0 50.1 53.8 57.7 1588 1787 2114 2419 2764 3164 3793 4480 5539 6649 8025 500 500 500 500 500 500 500 500 500 300 300 0.39 0.27 0.19 0.15 0.12 0.1 0.08 0.06 0.05 0.04 0.03 1278 1354 1526 1677 1836 2019 2308 2623 3065 3555 4128 0.64 0.44 0.32 0.25 0.21 0.16 0.13 0.1 0.08 0.06 0.05 CU AL Ω/km/phase 0.49 0.82 0.34 0.57 0.25 0.41 0.2 0.33 0.16 0.27 0.13 0.21 0.1 0.16 0.08 0.13 0.06 0.1 0.05 0.08 0.04 0.06 0.49 0.34 0.25 0.2 0.16 0.13 0.1 0.08 0.06 0.05 0.04 0.82 0.57 0.41 0.33 0.27 0.21 0.16 0.13 0.1 0.08 0.06 Impedance CU AL Ω/km/phase 0.517 0.836 0.371 0.586 0.282 0.433 0.236 0.350 0.204 0.294 0.177 0.244 0.153 0.200 0.139 0.173 0.129 0.151 0.120 0.135 0.112 0.122 0.517 0.371 0.282 0.236 0.204 0.177 0.153 0.139 0.129 0.120 0.112 0.836 0.586 0.433 0.350 0.294 0.244 0.200 0.173 0.151 0.135 0.122 ELECTRICAL PROPERTIES Sym. Asym. Current, in Current,in Capacitance 1sec 1sec CU uf/km/phase Current (I) Ground CU AL 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 57.2 71.5 90.0 AL kA 4.7 6.6 9.0 11.3 14.2 17.5 22.7 28.3 37.8 47.2 59.5 3.4 3.6 3.9 4.2 4.3 3.0 3.3 3.5 3.8 4.2 4.5 182.108 201.132 223.777 245.028 259.969 282.305 311.978 344.019 379.662 423.213 468.578 206 250 297 333 372 414 470 509 567 622 676 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 57.2 71.5 90.0 4.7 6.6 9.0 11.3 14.2 17.5 22.7 28.3 37.8 47.2 59.5 2.8 2.9 3.1 3.3 3.4 3.6 3.8 4.0 4.3 4.7 5.0 141.7481 155.2100 171.1653 186.0854 196.5494 212.1616 232.8540 255.1489 279.9040 309.9635 341.3560 206 250 297 333 372 414 470 509 567 622 676 Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. 160 195 232 263 293 329 377 415 468 523 580 Air CU AL Amps 243 189 302 236 365 286 416 327 471 370 531 421 616 491 681 552 775 636 669 725 963 821 165 200 238 266 298 331 376 407 454 498 541 128 156 186 210 234 263 302 332 374 418 464 160 195 232 263 293 329 377 415 468 523 580 243 302 365 416 471 531 616 681 775 669 963 165 200 238 266 298 331 376 407 454 498 541 128 156 186 210 234 263 302 332 374 418 464 189 236 286 327 370 421 491 552 636 725 821 Duct CU AL Armoured Medium Voltage (MV) XLPE Type A, 3 Cores, Power Cable , SANS 1339 Conductor: Annealed Copper or Aluminium Circular Compacted - Class 2 Phase Color Identification: Numbered, 1, 2 & 3 Application: Used for underground reticulation, main distribution system, sub-stationand mining. Can be manufactured with corrugated aluminium or steel tape. Outer-sheath can also be stripped blue or white according to customer requirements. 3.8/6.6kV - 3 Cores SWA PHYSICAL PROPERTIES Insulation Cable Core Overall Cable Mass Screen Size Diam. Diameter Diam. mm mm mm2 25 6.0 14.3 35 7.2 15.5 50 8.4 16.7 70 9.9 18.2 95 11.7 20.0 120 13.4 21.7 150 14.6 22.9 185 16.4 24.7 240 18.8 27.3 300 21.4 30.3 6.35/11kV 3 Cores SWA 25 6 16.1 35 7.2 17.3 50 8.4 18.5 70 9.9 20.0 95 11.7 21.8 120 13.4 23.5 150 14.6 24.7 185 16.4 26.5 240 18.8 28.9 300 21.4 31.5 mm 43.5 46.2 50.4 53.9 58.1 62.2 65.0 70.6 76.8 84.1 CU AL kg/km 3531 3067 4039 3389 5194 4266 6071 4772 7182 5419 8281 6054 9388 6604 11617 8183 13886 9432 16473 10905 49.1 51.9 54.9 58.3 62.6 66.9 71.0 75.2 81.0 87.2 4425 4974 5704 6600 7734 8889 10836 12322 14559 16997 3961 4324 4776 5301 5971 6662 8052 8888 10105 11429 Drum Resistance @ Resistance @ length 20°C 90°C Impedance ELECTRICAL PROPERTIES Sym. Asym. Current, in Current,in Capacitance 1sec 1sec uf/km/phase m 500 500 500 500 500 500 500 500 500 500 CU AL Ω/km/phase 0.927 1.540 0.668 0.110 0.494 0.822 0.342 0.568 0.247 0.411 0.196 0.325 0.159 0.265 0.128 0.211 0.099 0.162 0.080 0.130 CU AL Ω/km/phase 0.935 1.543 0.678 1.119 0.506 0.829 0.357 0.577 0.265 0.422 0.217 0.338 0.183 0.280 0.155 0.229 0.131 0.183 0.116 0.155 3.6 5.0 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 kA 2.3 3.2 4.6 6.4 8.7 11.0 13.8 17.0 22.1 27.6 15.8 17.1 15.8 17.1 18.6 19.9 20.9 27.7 30.2 33.5 259.035 291.463 323.754 363.980 412.112 457.470 489.445 537.356 580.516 605.340 131 160 198 240 282 320 358 405 462 508 500 500 500 500 500 500 500 500 500 500 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.099 0.075 0.06 0.927 0.668 0.494 0.342 0.247 0.196 0.159 0.128 0.099 0.080 0.935 0.678 0.506 0.357 0.265 0.217 0.183 0.155 0.131 0.116 3.6 5.0 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 2.3 3.2 4.6 6.4 8.7 11.0 13.8 17.0 22.1 27.6 15.5 16.4 17.4 18.6 20.2 21.5 27.7 29.7 32.1 34.5 205.632 229.780 253.773 283.609 319.249 352.793 376.419 411.798 458.882 509.806 131 160 198 240 282 320 358 405 462 508 1.540 0.110 0.822 0.568 0.411 0.325 0.265 0.211 0.162 0.130 1.543 1.119 0.829 0.577 0.422 0.338 0.280 0.229 0.183 0.155 AL Ground CU AL CU AL Ω/km/phase 0.727 1.200 0.524 0.868 0.387 0.641 0.268 0.443 0.193 0.320 0.153 0.253 0.124 0.206 0.099 0.164 0.075 0.125 0.060 0.099 1.200 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.099 CU Current (I) Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. 108 127 150 183 219 249 282 314 357 406 Air CU AL Amps 125 101 151 123 190 149 233 184 291 222 324 258 372 288 423 336 493 394 553 441 122 147 177 211 250 284 322 362 416 449 91 110 130 159 192 215 244 278 321 356 108 127 150 183 219 249 282 314 357 406 125 151 190 233 291 324 372 423 493 553 122 147 177 211 250 284 322 362 416 449 91 110 130 159 192 215 244 278 321 356 101 123 149 184 222 258 288 336 394 441 Duct CU AL Armoured Medium Voltage (MV) XLPE Type A, 3 Cores, Power Cable, SANS 1339 Conductor: Annealed Copper or Aluminium Circular Compacted - Class 2 Phase Color Identification: Numbered, 1, 2 & 3 Application: Used for underground reticulation, main distribution system, sub-station and mining. Can be manufactured with corrugated aluminium or steel tape. Outer-sheath can also be stripped blue or white according to customer requirements. 8.7/15kV - 3 Cores Unarmoured PHYSICAL PROPERTIES Insulation Cable Core Overall Size Diam. Screen Diameter Cable Mass Diam. CU mm2 mm mm mm 25 35 50 70 95 120 150 185 240 6.0 7.2 8.4 9.9 11.7 13.4 14.6 16.4 18.8 14.3 15.5 16.7 18.2 20 21.7 22.9 24.7 27.3 36.9 39.6 42.4 45.9 49.9 53.8 56.6 60.7 66.7 AL kg/km 4975 5539 6327 7250 8385 10359 11528 13109 15325 Drum Resistance length @ 20°C 4511 4889 5399 5951 6622 8132 8744 9676 10870 CU m 500 500 500 500 500 500 500 500 500 AL Ω/km/phase 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.099 0.075 1.200 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 ELECTRICAL PROPERTIES Sym. Asym. Current (I) Resistance @ Impedance Current, Current,in Capacitance 90°C Ground Air in 1sec 1sec CU AL CU AL CU AL CU AL CU AL uf/km/phase Ω/km/ Ω/km/phase kA Amps phase 0.927 1.540 0.935 1.543 3.6 2.3 17.0 174.527 131 108 125 101 0.668 0.110 0.678 1.119 5.0 3.2 18.0 193.942 160 127 151 123 0.494 0.822 0.506 0.829 7.2 4.6 18.9 213.192 198 150 190 149 0.342 0.568 0.357 0.577 10.0 6.4 20.2 237.085 240 183 233 184 0.247 0.411 0.265 0.422 13.6 8.7 21.8 265.580 282 219 291 222 0.196 0.325 0.217 0.338 17.2 11.0 28.2 292.362 320 249 324 258 0.159 0.265 0.183 0.280 21.5 13.8 29.7 311.210 358 282 372 288 0.128 0.211 0.155 0.229 26.5 17.0 31.6 339.413 405 314 423 336 0.099 0.162 0.131 0.183 34.3 22.1 34.0 376.918 462 357 493 394 Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Duct CU AL 122 147 177 211 250 284 322 362 416 91 110 130 159 192 215 244 278 321 Armoured Medium Voltage (MV) XLPE Type A, 3 Cores, Power Cable , SANS 1339 Conductor: Annealed Copper or Aluminium Circular Compacted - Class 2 Phase Color Identification: Numbered, 1, 2 & 3 Application: Used for underground reticulation, main distribution system, sub-station and mining. Can be manufactured with corrugated aluminium or steel tape. Outer-sheath can also be stripped blue or white according to customer requirements. 12.7/22kV - 3 Cores SWA PHYSICAL PROPERTIES Insulation Cable Core Overall Screen Size Diam. Diameter Cable Mass Diam. mm mm mm2 25 6.0 20.6 35 7.2 21.8 50 8.4 23.0 70 9.9 24.5 95 11.7 26.3 120 13.4 28.0 150 14.6 29.2 185 16.4 31.0 240 18.8 33.4 300 21.4 36.0 19/33kV 3 Cores SWA 50 8.4 228.4 70 9.9 29.9 95 11.7 31.7 120 13.4 33.4 150 14.6 34.6 185 16.4 36.4 240 18.8 38.8 300 21.4 41.4 mm 59.6 62.4 65.2 70.1 74.6 78.5 81.5 85.9 91.5 97.5 CU AL kg/km 5644 5180 6228 5579 6959 6031 8752 7452 10031 8268 11207 8980 12447 9663 14033 10599 16302 11847 18762 13193 79.8 83.3 88.3 92.4 95.2 99.5 105.2 111.4 9748 10735 12680 13997 15249 16886 19328 21984 8820 9436 10916 11769 12465 13453 14873 16415 Drum Resistance @ Resistance @ length 20°C 90°C Impedance ELECTRICAL PROPERTIES Sym. Asym. Current, in Current,in Capacitance 1sec 1sec uf/km/phase m 500 500 500 500 500 500 500 500 500 500 CU AL Ω/km/phase 0.927 1.540 0.668 0.110 0.494 0.822 0.342 0.568 0.247 0.411 0.196 0.325 0.159 0.265 0.128 0.211 0.099 0.162 0.080 0.130 CU AL Ω/km/phase 0.935 1.543 0.678 1.119 0.506 0.829 0.357 0.577 0.265 0.422 0.217 0.338 0.183 0.280 0.155 0.229 0.131 0.183 0.116 0.155 3.6 5.0 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 kA 2.3 3.2 4.6 6.4 8.7 11.0 13.8 17.0 22.1 27.6 19.0 19.9 21.1 27.3 29.2 31.1 32.1 34.0 36.4 38.9 178.367 197.244 219.704 240.775 255.586 277.726 255.586 277.726 307.134 338.884 131 160 198 240 282 320 358 405 462 508 500 500 500 500 500 500 500 500 0.387 0.268 0.193 0.153 0.124 0.099 0.075 0.06 0.494 0.342 0.247 0.196 0.159 0.128 0.099 0.080 0.506 0.357 0.265 0.217 0.183 0.155 0.131 0.116 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 4.6 6.4 8.7 11.0 13.8 17.0 22.1 27.6 31.6 33.0 38.9 40.8 42.0 44.4 46.8 49.9 140.887 154.233 170.048 184.836 195.207 210.679 231.183 253.275 198 240 282 320 358 405 462 508 0.822 0.568 0.411 0.325 0.265 0.211 0.162 0.130 0.829 0.577 0.422 0.338 0.280 0.229 0.183 0.155 AL Ground CU AL CU AL Ω/km/phase 0.727 1.200 0.524 0.868 0.387 0.641 0.268 0.443 0.193 0.320 0.153 0.253 0.124 0.206 0.099 0.164 0.075 0.125 0.060 0.099 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.099 CU Current (I) Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. 108 127 150 183 219 249 282 314 357 406 Air CU AL Amps 125 101 151 123 190 149 233 184 291 222 324 258 372 288 423 336 493 394 553 441 122 147 177 211 250 284 322 362 416 449 91 110 130 159 192 215 244 278 321 356 150 183 219 249 282 314 357 406 190 233 291 324 372 423 493 553 177 211 250 284 322 362 416 449 130 159 192 215 244 278 321 356 149 184 222 258 288 336 394 441 Duct CU AL Unarmoured Medium Voltage (MV) XLPE Type B, 3 Core, Power Cable , SANS 1339 Conductor: Annealed Copper or Aluminium Circular Compacted - Class 2 Phase Color Identification: Numbered, 1, 2 & 3 Application: Used for underground reticulation, main distribution system, sub-station and mining. Can be manufactured with corrugated aluminium or steel tape. Outer-sheath can also be stripped blue or white according to customer requirements. 3.8/6.6kV - 3 Cores Unarmoured PHYSICAL PROPERTIES Insulation Cable Core Overall Screen Size Diam. Diameter Cable Mass Diam. mm mm mm mm2 25 6.0 14.3 36.9 35 7.2 15.5 39.6 50 8.4 16.7 42.4 70 9.9 18.2 45.9 95 11.7 20 49.9 120 13.4 21.7 53.8 150 14.6 22.9 56.6 185 16.4 24.7 60.7 240 18.8 27.3 66.7 300 21.4 30.3 73.6 6.35/11kV 3 Cores Unarmoured 25 6 16.1 41.1 35 7.2 17.3 43.9 50 8.4 18.5 46.7 70 9.9 20.0 50.1 95 11.7 21.8 54.4 120 13.4 23.5 58.3 150 14.6 24.7 61.1 185 16.4 26.5 65.1 240 18.8 28.9 70.5 300 21.4 31.5 76.5 CU AL kg/km 1807 1343 2195 1545 2728 1800 3422 2122 4276 2513 5126 2899 6082 3298 7224 3790 9043 4588 11068 5499 2025 2426 2973 3683 4583 5453 6424 7588 9365 11340 1561 1776 2045 2383 2819 3226 3640 4154 4911 5771 Drum Resistance @ Resistance @ length 20°C 90°C Impedance ELECTRICAL PROPERTIES Sym. Asym. Current, in Current,in Capacitance 1sec 1sec uf/km/phase m 500 500 500 500 500 500 500 500 500 500 CU AL Ω/km/phase 0.927 1.540 0.668 0.110 0.494 0.822 0.342 0.568 0.247 0.411 0.196 0.325 0.159 0.265 0.128 0.211 0.099 0.162 0.080 0.130 CU AL Ω/km/phase 0.935 1.543 0.678 1.119 0.506 0.829 0.357 0.577 0.265 0.422 0.217 0.338 0.183 0.280 0.155 0.229 0.131 0.183 0.116 0.155 3.6 5.0 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 kA 2.3 3.2 4.6 6.4 8.7 11.0 13.8 17.0 22.1 27.6 2.0 2.2 2.4 2.6 2.8 3.1 3.2 3.5 3.9 4.3 259.035 291.463 323.754 363.980 412.112 457.470 489.445 537.356 580.516 605.340 131 160 198 240 282 320 358 405 462 508 500 500 500 500 500 500 500 500 500 500 0.73 0.52 0.39 0.27 0.19 0.15 0.12 0.1 0.08 0.06 0.927 0.668 0.494 0.342 0.247 0.196 0.159 0.128 0.099 0.080 0.935 0.678 0.506 0.357 0.265 0.217 0.183 0.155 0.131 0.116 3.6 5.0 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 2.3 3.2 4.6 6.4 8.7 11.0 13.8 17.0 22.1 27.6 2.3 2.5 2.6 2.9 3.1 3.3 3.5 3.8 4.1 4.5 205.632 229.780 253.773 283.609 319.249 352.793 376.419 411.798 458.882 509.806 131 160 198 240 282 320 358 405 462 508 1.540 0.110 0.822 0.568 0.411 0.325 0.265 0.211 0.162 0.130 1.543 1.119 0.829 0.577 0.422 0.338 0.280 0.229 0.183 0.155 AL Ground CU AL CU AL Ω/km/phase 0.727 1.200 0.524 0.868 0.387 0.641 0.268 0.443 0.193 0.320 0.153 0.253 0.124 0.206 0.099 0.164 0.075 0.125 0.060 0.099 1.200 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.099 CU Current (I) Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. 108 127 150 183 219 249 282 314 357 406 Air CU AL Amps 125 101 151 123 190 149 233 184 291 222 324 258 372 288 423 336 493 394 553 441 122 147 177 211 250 284 322 362 416 449 91 110 130 159 192 215 244 278 321 356 108 127 150 183 219 249 282 314 357 406 125 151 190 233 291 324 372 423 493 553 122 147 177 211 250 284 322 362 416 449 91 110 130 159 192 215 244 278 321 356 101 123 149 184 222 258 288 336 394 441 Duct CU AL Unarmoured Medium Voltage (MV) XLPE Type B, 3 Core, Power Cable , SANS 1339 Conductor: Annealed Copper or Aluminium Circular Compacted - Class 2 Phase Color Identification: Numbered, 1, 2 & 3 Application: Used for underground reticulation, main distribution system, sub-station and mining. Can be manufactured with corrugated aluminum or steel tape. Outer-sheath can also be stripped blue or white according to customer requirements. 12.7/22kV - 3 Cores Unarmoured PHYSICAL PROPERTIES Insulation Cable Core Overall Screen Size Diam. Diameter Cable Mass Diam. mm mm mm2 25 6.0 20.6 35 7.2 21.8 50 8.4 23.0 70 9.9 24.5 95 11.7 26.3 120 13.4 28.0 150 14.6 29.2 185 16.4 31.0 240 18.8 33.4 300 21.4 36.0 19/33kV 3 Cores Unarmoured 50 8.4 28.4 70 9.9 29.9 95 11.7 31.7 120 13.4 33.4 150 14.6 34.6 185 16.4 36.4 240 18.8 38.8 300 21.4 41.4 mm 51.6 54.4 57.2 60.6 64.7 68.6 71.6 75.6 81.2 87.0 CU AL kg/km 2679 2216 3116 2466 3697 2770 4450 3151 5373 3610 6289 4062 7330 4546 8543 5109 10427 5972 12435 6867 69.7 73.2 77.2 81.3 84.1 88.2 93.7 99.5 4707 5509 6489 7501 8548 9819 11784 13873 3779 4209 4726 5274 5764 6385 7329 8304 Drum Resistance @ Resistance @ length 20°C 90°C Impedance ELECTRICAL PROPERTIES Sym. Asym. Current, in Current,in Capacitance 1sec 1sec uf/km/phase m 500 500 500 500 500 500 500 500 500 500 CU AL Ω/km/phase 0.927 1.540 0.668 0.110 0.494 0.822 0.342 0.568 0.247 0.411 0.196 0.325 0.159 0.265 0.128 0.211 0.099 0.162 0.080 0.130 CU AL Ω/km/phase 0.935 1.543 0.678 1.119 0.506 0.829 0.357 0.577 0.265 0.422 0.217 0.338 0.183 0.280 0.155 0.229 0.131 0.183 0.116 0.155 3.6 5.0 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 kA 2.3 3.2 4.6 6.4 8.7 11.0 13.8 17.0 22.1 27.6 2.9 3.1 3.3 3.5 3.7 4.0 4.1 4.4 4.7 5.1 147.703 163.122 178.367 197.244 219.704 240.775 255.586 277.726 307.134 338.884 131 160 198 240 282 320 358 405 462 508 500 500 500 500 500 500 500 500 0.39 0.27 0.19 0.15 0.12 0.1 0.08 0.06 0.494 0.342 0.247 0.196 0.159 0.128 0.099 0.080 0.506 0.357 0.265 0.217 0.183 0.155 0.131 0.116 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 4.6 6.4 8.7 11.0 13.8 17.0 22.1 27.6 4.0 4.2 4.5 4.7 4.9 5.1 5.5 5.8 140.887 154.233 170.048 184.836 195.207 210.679 231.183 253.275 198 240 282 320 358 405 462 508 0.822 0.568 0.411 0.325 0.265 0.211 0.162 0.130 0.829 0.577 0.422 0.338 0.280 0.229 0.183 0.155 AL Ground CU AL CU AL Ω/km/phase 0.727 1.200 0.524 0.868 0.387 0.641 0.268 0.443 0.193 0.320 0.153 0.253 0.124 0.206 0.099 0.164 0.075 0.125 0.060 0.099 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.099 CU Current (I) Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. 108 127 150 183 219 249 282 314 357 406 Air CU AL Amps 125 101 151 123 190 149 233 184 291 222 324 258 372 288 423 336 493 394 553 441 122 147 177 211 250 284 322 362 416 449 91 110 130 159 192 215 244 278 321 356 150 183 219 249 282 314 357 406 190 233 291 324 372 423 493 553 177 211 250 284 322 362 416 449 130 159 192 215 244 278 321 356 149 184 222 258 288 336 394 441 Duct CU AL All Aluminium Alloy Conductors (AAAC) Overhead Conductors Cable Description: All Aluminium Alloy Conductors (AAAC) Application: Used for overhead power lines Specification: SANS 182 & IEC 61089 CODE Name ACACIA ALMOND CEDAR 35 FIR HAZEL PINE 70 WILLOW 80 90 OAK 100 MULBERRY ASH ELM POPLAR 225 SYCAMORE UPAS 350 YEW Equival. copper area mm² 13 16 19 22 25 32 38 45 48 51 58 63 63 80 96 112 119 143 161 192 224 254 Stranding and wire diameter mm 7/2,08 7/2,34 7/2,54 7/2,77 7/2,95 7/3,30 7/3,61 7/3,91 7/4,04 7/4,19 7/4,45 7/4,65 19/2,82 19/3,18 19/3,48 19/3,76 37/2,87 37/3,05 37/3,23 37/3,53 37/3,81 37/4,06 Overall Aluminium diameter area mm 6,24 7,02 7,59 8,31 8,85 9,9 10,83 11,73 12,12 12,57 13,35 13,95 14,1 16,9 17,4 18,8 20,09 21,35 22,61 24,71 26,67 28,42 mm² 23,79 30,1 35,47 42,18 47,84 59,87 71,65 84,05 89,73 96,52 108,9 118,9 118,7 150,9 180,7 210,9 239,4 270,3 303,2 362,1 421,8 479 Mass kg/km 65 82 97 115 131 164 196 230 245 264 298 325 326 415 497 580 660 744 835 997 1162 1319 Ultimate tensile strength Newton 6690 8440 9960 11860 13430 16820 20200 23630 25200 27060 30400 33330 33330 42350 50690 59220 67350 75780 85000 101670 118430 134510 Coefficient Initial final DC of linear modulus of modulus of resistance expansion elasticity elasticity at 20°C /C°x10-6 MPa MPa Ω/km 23 52500 61000 1,39 23 52400 61000 1,1 23 52400 61000 0,934 23 52400 61000 0,785 23 52400 61000 0,692 23 52400 61000 0,553 23 52400 61000 0,462 23 52400 61000 0,394 23 52400 61000 0,369 23 52400 61000 0,343 23 52400 61000 0,306 23 52400 61000 0,279 23 49650 59650 0,28 23 49650 59650 0,221 23 49650 59650 0,184 23 49650 59650 0,158 23 48250 58600 0,139 23 48250 58600 0,123 23 48250 58600 0,11 23 48250 58600 0,0921 23 48250 58600 0,0791 23 48250 58600 0,0696 Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Current rating A 133 153 169 189 204 235 262 290 302 316 339 359 359 416 467 513 551 600 643 718 789 853 Standard drum length m 3000 2500 2500 2500 2500 2500 2500 2000 1500 1500 1000 1000 2000 2000 2000 2000 2000 2000 2000 2000 1500 1500 All Aluminium Conductors (AAC) Overhead Conductors Cable Description: All Aluminium Conductors (AAC) Application: Used for overhead power lines Specification: SANS 182 & IEC 61089 Code Name MIDGE APHIS GNAT WEEVIL MOSQUITO LADYBIRD ANT FLY BLUEBOTTLE EARWIG GRASSHOPPER CLEGG WASP BEETLE BEE CRICKET HORNET CATERPILLAR CHAFER SPIDER COCKROACH BUTTERFLY MOTH DRONE LOCUST CENTIPEDE MAYBUG SCORPION CICADA TARANTULA Area of Aluminium Nominal (mm²) 22 25 25 30 35 40 50 60 70 75 80 90 100 100 125 150 150 175 200 225 250 300 350 350 400 400 450 500 600 750 Actual (mm²) 23,33 24,89 26,85 31,56 36,88 42,79 52,83 63,55 73,65 78,55 84,05 95,6 106 106,4 132 157,9 157,6 185,9 213,2 237,6 265,7 322,7 373,1 372,4 428,7 415,2 486,1 529,8 628,3 794,9 Stranding N. of wires X Diam. Nominal Diameter of Conductor Nominal Mass Rated Strength Current Carrying Capacity (Amperes) Electrical Resistance at 20°C Maximum (mm) 7X2,06 3X3,35 7X2,21 3X3,66 7X2,59 7X2,79 7X3,10 7X3,40 7X3,66 7X3,78 7X3,91 7X4,17 7X4,39 19X2,67 7X4,90 7X5,36 19X3,25 19X3,53 19X3,78 19X3,99 19X4,22 19X4,65 19X5,00 37X3,58 19X5,36 37X3,78 37X4,09 37X4,27 27X4,65 27X5,23 (mm) 6,18 7,21 6,63 7,87 7,77 8,37 9,3 10,2 10,98 11,34 11,73 12,51 13,17 13,35 14,7 16,08 16,25 17,65 18,9 19,95 21,1 23,25 25 25,06 26,8 26,46 28,63 29,89 32,55 36,61 (kg/kg) 64,3 68,6 74 87 101,7 118 145,7 175,2 203,1 216,6 231,7 263,6 292,2 293,3 363,9 435,3 434,5 512,5 587,8 655,1 732,6 889,7 1028 1027 1182 1145 1340 1461 1732 2068 (kN) 4,26 4,38 4,9 5,12 6,37 7,39 8,62 10,37 12,02 12,82 13,31 15,14 16,79 17,81 20,91 24,21 24,91 29,39 33,71 36,46 40,77 49,52 57,25 57,51 63,79 64,23 72,99 79,44 94,34 119,4 Amperes) 135 150 150 170 185 200 230 260 285 290 310 340 360 365 415 470 470 520 570 610 655 745 820 815 890 875 970 1020 1115 1295 (ohm/km) 1,23572 1,15827 1,07372 0,91348 0,7817 0,67374 0,5457 0,45365 0,39144 0,36702 0,343 0,30156 0,27197 0,27095 0,2184 0,18258 0,18292 0,15508 0,13522 0,12134 0,1085 0,08934 0,07727 0,07741 0,06725 0,06943 0,0593 0,05451 0,04588 0,3626 Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Aluminium Conductor Steel Reinforced (ACSR) Overhead Conductors Cable Description: Aluminium Conductor Steel Reinforced Application: Used for overhead power lines Specification: SANS 182 & IEC 61089 Equival. Copper area Stranding and wire diameter MOLE SQUIRREL GOPHER WEASEL FOX FERRET RABBIT MINK SKUNK BEAVER HORSE RACCOON OTTER CAT HARE DOG mm² 6,45 12,9 16,3 19,35 22,58 25,81 32,26 38,71 38,71 45,16 45,16 48,39 51,61 58,06 64,52 64,52 HYENA 64,52 LEOPARD 80,65 COYOTE 80,65 TIGER WOLF LYNX PANTHER LION BEAR GOAT SHEEP ANTELOPE BISON DEER ZEBRA ELK CAMEL MOOSE 80,65 96,77 112,9 129 145,2 161,3 193,5 225,8 225,8 225,8 258,1 258,1 290,3 290,3 322,5 mm 6/1/1,50 6/1/2,11 6/1/2,36 6/1/2,59 6/1/2,79 6/1/3,00 6/1/3,35 6/1/3,66 12/7/2,59 6/1/3,99 12/7/2,79 6/1/4,09 6/1/4,22 6/1/4,50 6/1/4,72 6/4,72 4,458598726 7/4,39 3,626943005 6/5,28 4 26/2,87 3,664921466 30/7/2,36 30/7/2,59 30/7/2,79 30/7/3,00 30/7/3,18 30/7/3,35 30/7/3,71 30/7/3,99 54/7/2,97 54/7/3,00 30/7/4,27 54/7/3,18 30/7/4,50 54/7/3,35 54/7/3,53 Code name Diameter Overall Aluminium Steel area over steel diameter area (Std.) Total area Ultimate tensile strength Mass kg/km cient Initial Breaking Coeffi of linear modulus load of expansion elasticity Final DC modulus resistance Current of at 20°C rating elasticity (Std) Standard drum length Aluminium Steel Total 29,2 57,7 72,2 87 101 117 145 174 175 206 203 217 231 263 289 289 13,9 27,5 34,4 41,5 48,1 55,6 69,4 82,8 292 98,4 338 103 110 125 138 100 43,1 85,2 107 129 149 173 214 257 467 304 541 320 341 388 427 389 newtons 4780 8020 9610 11450 13100 15200 18500 21900 52900 25900 60700 27200 28900 32800 36000 34700 kg 487 818 990 1160 1340 1530 1890 2230 5390 2640 6190 2770 2950 3340 3670 3540 /C° x10-6 19,31 19,31 19,31 19,31 19,31 19,31 19,31 19,31 15,84 19,31 15,84 19,31 19,31 19,31 19,31 19,92 N/mm² 65000 54600 52700 51500 50700 50200 49500 49100 71900 48800 71000 48700 48700 48500 48500 48800 N/mm² 80400 80400 80400 80400 80400 80400 80400 80400 108000 80400 108000 80400 80400 80400 80400 76400 ohms/km 2,7062 1,3677 1,0933 0,9077 0,7822 0,6766 0,5426 0,4546 0,4571 0,3825 0,3939 0,364 0,03419 0,3007 0,2733 0,2733 amps 87 130 150 170 190 210 240 260 270 290 300 300 310 340 360 360 m 3000 3000 3000 2500 2500 1500 1500 1500 2000 1500 2000 1500 1500 1500 1500 2000 126,43 291 162 453 41900 4270 18,93 52400 82200 0,2697 360 2000 16,84 148,21 361 133 494 42200 4300 19,54 47800 76300 0,2184 410 2000 131,74 20,06 151,8 365 159 524 47300 4820 19,54 51900 76000 0,3035 420 2000 131,23 158,06 183,41 212,06 238,27 264,42 324,31 375,11 374,11 381,7 429,6 428,88 477,13 475,96 528,49 30,62 36,88 42,8 49,48 55,6 61,7 75,67 87,53 48,5 49,48 100,24 55,6 111,33 61,7 68,51 161,85 194,94 226,2 261,54 293,86 326,12 399,98 462,63 422,6 431,18 529,84 484,48 588,46 537,66 596,99 364 438 508 588 660 733 899 1040 1040 1060 1190 1190 1320 1320 1460 242 292 330 391 440 488 598 692 383 391 792 440 880 488 542 606 730 846 970 1100 1220 1500 1730 1420 1450 1980 1630 2200 1810 2000 58700 69200 79300 90800 101000 112000 136000 157000 117000 119000 179000 133000 199000 147000 162000 5980 7050 8080 9260 10300 11400 13900 16000 11900 12100 18200 13600 20300 15000 16500 18,43 18,43 18,43 18,43 18,43 18,43 18,43 18,43 19,91 19,91 18,43 19,91 18,43 19,91 19,91 56900 55700 54900 54300 53900 53600 53100 52900 47700 47600 52800 47300 52700 47000 46700 83400 83400 83400 83400 83400 83400 83400 83400 73200 73200 83400 73200 83400 73200 73200 0,2202 0,1828 0,1576 0,1363 0,1213 0,1093 0,0891 0,077 0,0773 0,0757 0,0673 0,0674 0,0606 0,0607 0,0547 420 470 520 560 610 650 730 800 790 800 870 860 930 920 980 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 1500 2000 2000 2000 mm 1,5 2,11 2,36 2,59 2,79 3 3,35 3,66 7,77 3,99 8,37 4,09 4,22 4,5 4,72 4,71 mm 4,5 6,33 7,08 7,77 8,37 9 10,05 10,98 12,95 11,97 13,95 12,27 12,66 13,5 14,16 14,15 mm² 10,6 20,98 26,25 31,61 36,68 42,41 52,88 63,13 63,22 75,02 73,36 78,83 83,92 95,43 104,98 104,98 mm² 1,77 3,5 4,37 5,27 6,11 7,07 8,81 10,52 36,88 12,5 42,8 13,14 13,99 15,9 17,5 12,7 mm² 12,37 24,48 30,62 36,88 42,8 49,48 61,7 73,65 100,1 87,53 116,16 91,97 97,91 111,33 122,48 117,69 5,79 14,57 105,95 20,48 5,25 15,81 131,37 5,73 15,89 4,72 7,77 8,37 9 9,54 10,05 11,13 11,97 8,91 9 12,81 9,54 13,5 10,05 10,59 16,52 18,13 19,53 21 22,26 23,45 25,97 27,93 26,73 27 29,89 28,62 31,5 30,15 31,77 Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. Flexible PVC Insulated Submersible Pump Cable, Low Voltage Power Cable 0.6/1 kV, SABS 1574, 70ºC Conductor: Flexible Copper – Class 5 Insulation: PVC Nitrile Flexible Grade Sheathing: PVC Nitrile Flexible Grade Phase Color Code: Red , Yellow, Blue or Black Application: Used for outdoors and indoors, mobile, portable and fixed pumping equipment. Three core with blue outer-sheath and four cores with green outer-sheath. Flexible PVC Submersible Pump Cable - 600/1000V PHYSICAL PROPERTIES Approximate Diameter Cable Size Cond. Diam. Insul. Diam. 3C 4C 2 mm mm mm mm mm 1.5 1.7 3.3 9.7 10.7 2.5 2.2 3.8 10.8 11.9 4 2.6 4.6 12.9 14.7 6 3.9 5.9 16.0 18.2 10 4.7 7.2 19.3 21.8 16 5.8 8.4 22.1 25.3 25 7.3 10.2 26.7 30.2 35 9.4 12.3 32.0 36.1 50 11.2 14.5 37.9 43.1 70 13.1 16.4 41.8 47.6 95 15.3 19.1 49.0 55.6 Approximate Mass 3C Kg/km 120 160 240 345 520 740 1125 1552 2205 2870 3925 4C kg/km 145 195 310 445 660 970 1440 1980 2835 3700 5040 Drum length m 500 500 500 500 500 500 500 500 500 500 500 ELECTRICAL PROPERTIES DC Resistance @ Symmetrical Current in Air Current 20°C Ω/km/phase kA(1 sec) Amps 13.300 0.2 16 7.980 0.3 20 4.950 0.5 25 3.300 0.7 34 1.910 1.2 47 1.210 1.8 63 0.780 2.9 83 0.554 4.0 102 0.386 5.8 124 0.272 8.1 158 0.206 10.9 192 Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. PVC Nitrile Trailing Cable, Low Voltage Power Cable 0.6/1 kV, SABS 1574, 70ºC Conductor: Flexible Copper – Class 5 Insulation: PVC Nitrile Flexible grade Sheathing: PVC Nitrile Flexible Grade Phase Color Code: Red, Yellow, Blue or Black Application: Used for outdoors and indoors, mobile, portable and fixed pumping equipment. PVC Nitrile Trailing Cable - 600/1000V Cable Size Cond. Diam. mm 1.5 2.5 4 6 10 16 25 35 50 70 95 mm 1.7 2.2 2.6 3.9 4.7 5.8 7.3 9.4 11.2 13.1 15.3 2 PHYSICAL PROPERTIES Approximate Insul. Diam. Diameter mm mm 3.3 10.7 3.8 11.9 4.6 14.7 5.9 18.2 7.2 21.8 8.4 25.3 10.2 30.2 12.3 36.1 14.5 43.1 16.4 47.6 19.1 55.5 Approximate Mass Kg/km 150 202 320 456 680 990 1470 2015 2890 3760 5120 Drum length m 500 500 500 500 500 500 500 500 500 500 500 ELECTRICAL PROPERTIES DC Resistance Symmetrical Current in Air @ 20°C Current Ω/km/phase kA(1 sec) Amps 13.300 0.2 16 7.980 0.3 20 4.950 0.5 25 3.300 0.7 34 1.910 1.2 47 1.210 1.8 63 0.780 2.9 83 0.554 4.0 102 0.386 5.8 124 0.272 8.1 158 0.206 10.9 192 Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities. TROLLEY WIRE Conductor: Copper Rod with Groove Application: Used for fixed electric traction insulation Specification: BS EN 50149 + Customer PHYSICAL PROPERTIES Cable Size mm2 81 107 161 MECHANICAL & ELECTRICAL PROPERTIES Approx. Diameter mm 10.6 12.3 15.0 Approximate Mass Kg/km 711 951 1431 Drum length Tensile Strength Hardness Torsion Test Bending Test DC Resistance @ 20°C m 1000 1000 1000 355 350 318 54 54 54 5 5 5 5 5 5 0.229 0.170 0.108 Note: Red Stripe – Fire Retardant Cable (FR) White Stripe – Halogen Free Cable (HFC) Blue Stripe – Low Halogen Cable (LHC) Diagrams of cables are illustrative only and not necessarily to scale. General Cable SUB-SAHARA Africa reserves the right to change or vary the construction of any of their product without notice. Whilst every care has been taken in the preparation of this publication, General Cable SUB-SAHARA Africa accept no liability of any kind and are not responsible for results of any action on the basis of this information or resulting from errors or omission. This technical data sheet is intended as a guide only, any person using it must make reference to appropriate local standards or authorities.