001-008 Contents.qxd - American Electric Lighting

advertisement
American
Electric
Lighting
Product Guide
Edition Two
We are pleased to present the second edition of the American Electric Lighting and Dark to Light product guide. AEL is a company
on the move in the pubic infrastructure market, with products that have been successful for over 50 years in roadway, security,
area, flood and decorative lighting. DTL has been a large part of that success by offering top-of-the-line photocontrols. Our goal is
to continue to provide the superior design, quality and reliability that our customers demand.
As you review the new guide, be sure to look for the NEW designation on products throughout the catalog. We have added over 70
pages of information to the Decorative Post Tops section, including an extensive expansion of the Heritage family.
Also new in this edition are ballast and optical performance matrices at the end of each product section. Use them to help
determine the best ballast and optical configurations for your needs. Also, a selection guide has been added to the DTL pages to
help you choose the best photocontrols for your application. In addition, you will also find a Frequently Ordered Products section
near the end of the guide.
For the most up-to-date product information, photometric files, specification sheets and other technical data that AEL and DTL
have to offer, visit our website, www.americanelectriclighting.com.
We at American Electric Lighting are confident this catalog will be a useful tool for you. We look forward to working with you to
satisfy your lighting requirements. Thank you for your continued support.
Sincerely,
The AEL Team
American Electric Lighting™
Roadway Lighting
TA B L E
O F
C O N T E N T S
ROADWAY LIGHTING
2
DuraStar™ Roadway Lighting System Series 20
Product Overview ...............................10
Ordering Information ..........................11
Roadway Cobrahead Series 325
Product Overview ...............................26
Ordering Information ..........................27
DuraStar™ Roadway Lighting System Series 30
Product Overview ...............................12
Ordering Information ..........................13
Roadway Cutoff Cobrahead Series 325
Product Overview ...............................28
Ordering Information ..........................29
Roadway Cobrahead Series 115
Product Overview ...............................14
Ordering Information ..........................15
Roadway Cobrahead Series 327
Product Overview ...............................30
Ordering Information ..........................31
Roadway Cutoff Cobrahead Series 115
Product Overview ...............................16
Ordering Information ..........................17
Roadway Cobrahead Series 413
Product Overview ...............................32
Ordering Information ..........................33
Roadway Cobrahead Series 315
Product Overview ...............................18
Ordering Information ..........................19
Multi-Mount™ Series 285
Product Overview ...............................34
Ordering Information ..........................35
Roadway Cutoff Cobrahead Series 315
Product Overview ...............................20
Ordering Information ..........................21
InterState™ II Luminaire Series 775
Product Overview ...............................36
Ordering Information ..........................37
Roadway Cobrahead Series 125
Product Overview ...............................22
Ordering Information ..........................23
LPS Roadway/Area Luminaire Series SRP
Product Overview ...............................38
Ordering Information ..........................39
Roadway Cutoff Cobrahead Series 125
Product Overview ...............................24
Ordering Information ..........................25
LPS Roadway/Area Luminaire Series SRX
Product Overview ...............................40
Ordering Information ..........................41
Product Guide
American Electric Lighting™
Roadway Lighting, Decorative Post Top Lighting
TA B L E
O F
C O N T E N T S
LPS Roadway/Area Luminaire Series SP2
Product Overview ...............................42
Ordering Information ..........................43
Cresthill Classic
Underpass Series GST
Product Overview ...............................44
Ordering Information ..........................45
Cresthill Sphere
Underpass Series 581/681
Product Overview ...............................46
Ordering Information ..........................47
Cresthill Centennial
Product Overview................................70
Ordering Information ..........................71
Wall Pack 882
Cresthill Glass
Product Overview................................66
Ordering Information ..........................67
Product Overview................................68
Ordering Information ..........................69
Product Overview ...............................48
Ordering Information ..........................49
Product Overview................................72
Ordering Information ..........................73
Signlite Series 875
Product Overview ...............................50
Ordering Information ..........................51
Lexington
Accessories..........................................................................52
Heritage Collection Syracuse Series
Product Overview................................76
Ordering Information ..........................77
Ballast Matrices ..................................................................54
DECORATIVE AND POST-TOP LIGHTING
Heritage Collection
Product Overview................................74
Ordering Information ..........................75
Victorian Series
Product Overview................................78
Ordering Information ..........................79
Marietta Series
Product Overview ...............................62
Ordering Information ..........................63
Yorktown
Sumter Series
Product Overview ...............................64
Ordering Information ..........................65
Product Overview................................80
Ordering Information ..........................81
Product Guide
3
American Electric Lighting™
Decorative Post Top Lighting
TA B L E
O F
C O N T E N T S
Heritage Collection
Branson
Product Overview................................82
Ordering Information ..........................83
Bainbridge Series
Product Overview................................96
Ordering Information ..........................97
Georgian Series
Depot
Product Overview................................98
Ordering Information ..........................99
Product Overview................................84
Ordering Information ..........................85
Heritage Series
American Revolution Series 247
Product Overview................................86
Ordering Information ..........................87
American Revolution Series 247
Product Overview................................88
Ordering Information ..........................89
Contemporary Series 245
Product Overview................................90
Ordering Information ..........................91
Chadsworth Series
Product Overview..............................100
Ordering Information ........................101
New Albany Series
Product Overview..............................102
Ordering Information ........................103
Statesboro Series
Product Overview..............................104
Ordering Information ........................105
Waycross Series
Product Overview..............................106
Ordering Information ........................107
Weatherproof Receptacles ..........................................108
Residential Series RES
Product Overview................................92
Ordering Information ..........................93
TwistPack Series TWT
Product Overview................................94
Ordering Information ..........................95
Banner Arms
Product Overview..............................110
Ordering Information ........................111
Flagpole Holders
Product Overview..............................112
Ordering Information ........................113
Street Signs, Octagonal Frames
Product Overview..............................114
Ordering Information ........................115
Street Signs, Oval Frames
Product Overview..............................116
Ordering Information ........................117
4
Product Guide
American Electric Lighting™
Decorative Post Top, Security Lighting, Area Lighting
TA B L E
O F
C O N T E N T S
Heritage Series
Street Signs, Rectangular Frames
Product Overview..........................118
Ordering Information.....................119
Series 11 “L” Package
Product Overview..............................146
Ordering Information ........................147
Street Signs, Curved Frames
Product Overview..........................120
Ordering Information.....................121
Series 110
Product Overview..............................148
Ordering Information ........................149
Ladder Rests ....................................................................122
Post Top Finials................................................................123
WTA Series Cross Arms and Wall Brackets
Product Overview..........................126
Ordering Information.....................126
Diagrams.........................................127
OS Series Cross Arms and Wall Brackets
Product Overview..........................128
Ordering Information.....................128
Diagrams.........................................129
Dusk to Dawn Series DTD
Product Overview..............................150
Ordering Information ........................151
Series 165
Product Overview..............................152
Ordering Information ........................153
Orientation Guide ............................................................130
Ballast Matrices ..............................................................132
Accessories ........................................................................154
Ballast Matrices .................................................................155
SECURITY LIGHTING
315 Series
Product Overview..........................140
Ordering Information.....................141
AREA LIGHTING
AVL
Product Overview..............................158
Ordering Information ........................159
NEMA Head 11
Product Overview..........................142
Ordering Information.....................143
NEMA Head Package Series 11 PKG
Product Overview..........................144
Ordering Information.....................145
LuxMaster® Luminaire 53
Product Overview..............................160
Ordering Information ........................161
LuxMaster® Luminaire 153
Product Overview..............................162
Ordering Information ........................163
Product Guide
5
American Electric Lighting™
Area Lighting, Floodlighting, Photocontrols
TA B L E
O F
C O N T E N T S
LuxMaster® Classic Series LS
Product Overview .............................164
Ordering Information ........................165
Quartz Flood Series 570
Product Overview .............................186
Ordering Information ........................186
LuxMaster® Classic Series LM
Product Overview .............................166
Ordering Information ........................167
Quartz Flood Series 474
Product Overview .............................187
Ordering Information ........................187
LuxMaster® Classic Series LL
Product Overview .............................168
Ordering Information ........................169
AmeriSport Series ASP
Product Overview .............................188
Ordering Information ........................189
LuxMaster® Luminaire Series LML
Product Overview .............................170
Ordering Information ........................171
Sportslighting Series SPF
Product Overview .............................190
Ordering Information ........................191
Accessories.......................................................................172
Accessories .........................................................................192
Ballast Matrices ...............................................................176
Ballast Matrices ..................................................................197
FLOODLIGHTING
Compact Flood Series 51
Product Overview .............................180
Ordering Information ........................181
ELECTRONIC PHOTOCONTROLS
DE Series Silicon
Product Overview .............................200
Ordering Information ........................200
DD Series Classic
UltraFloodTM Series 75
Product Overview .............................182
Ordering Information ........................183
Product Overview .............................201
Ordering Information ........................201
DPN Series
UltraFloodTM Series 77
Product Overview .............................184
Ordering Information ........................185
Ordering Information ........................133
6
Product Guide
Product Overview .............................202
Ordering Information ........................202
American Electric Lighting™
Photocontrols, Poles, Options & Accessories
TA B L E
O F
C O N T E N T S
DP Series Filtered Silicon
Product Overview..........................203
Ordering Information.....................203
Shorting Cap
D Series Classic
Accessories & Special Controls ...........................................212
Product Overview..................................211
Ordering Information ............................211
Product Overview..........................204
Ordering Information.....................204
POLES
®
DX Series Part Night
Product Overview..........................205
Ordering Information.....................205
DUX Series Basic
Product Overview..........................206
Ordering Information.....................206
DBE Series Button
Product Overview..........................207
Ordering Information.....................207
DB Series Button
Product Overview..........................208
Ordering Information.....................208
DA Series Button
Product Overview..........................209
Ordering Information.....................209
D779 Series
Product Overview..........................210
Ordering Information.....................210
RSA ...................................................................................218
RTA ...................................................................................219
RSAH .................................................................................220
SSA ...................................................................................221
SSAH .................................................................................222
RSS ...................................................................................223
RTS ...................................................................................224
SSS ...................................................................................225
STS ...................................................................................226
STSH..................................................................................227
Pole Options .....................................................................228
Aluminum Mounting Brackets ......................................229
Steel Mounting Brackets...............................................230
RTF ...................................................................................231
RTFDB ...............................................................................232
SSF ...................................................................................233
RTCD..................................................................................234
RTCDDB ............................................................................235
STC ...................................................................................236
SPRTC ...............................................................................237
SPRTS ...............................................................................241
RTAU..................................................................................244
RTSU..................................................................................248
AMAW / SMAW...............................................................250
AMAC / SMAC .................................................................252
SMAWL.............................................................................254
Options & Accessories ..................................................256
OPTIONS & ACCESSORIES
HPS Replacement Starters............................................266
Lamp Selection ................................................................267
Fuse Ratings.....................................................................268
Luminaire Classification Systems. ...............................274
Floodlighting Applications. ............................................275
Floodlight Calculations ...................................................276
Roadway Lighting Application Design.........................277
Terms & Conditions.........................................................278
Index..................................................................................280
Product Guide
7
8
Product Guide
ROADWAY LIGHTING
DuraStar™ Series 20 ...............................................10
DuraStar™ Series 30 ...............................................12
Roadway 115 ............................................................14
Roadway 115 Cutoff .................................................16
Roadway 315 ............................................................18
Roadway 315 Cutoff .................................................20
Roadway 125 ............................................................22
Roadway 125 Cutoff .................................................24
Roadway 325 ............................................................26
Roadway 325 Cutoff .................................................28
Roadway 327 .............................................................30
Roadway 413 .............................................................32
Multi-Mount™ 285....................................................34
InterState™ II 775....................................................36
LPS Roadway - SRP .................................................38
LPS Roadway - SRX .................................................40
LPS Roadway - SP2..................................................42
Underpass GST.........................................................44
Underpass 581/681 ...................................................46
Heavy-Duty Wallpack 882.......................................48
Signlite 875 ................................................................50
Accessories ..............................................................52
Ballast Matrices .......................................................54
American Electric Lighting™
DuraStar™ Series 20
Roadway Lighting System
35-150W HPS, 100-175W MV/MH
P R O D U C T
O V E R V I E W
Features:
Revolutionary DuraLock™ docking system provides modular installation and
interchangeability for easy maintenance. Rugged die-cast, powder-coated
docking station mounts securely to mast-arm to ensure secure wiring and
long-lasting stability. Durable lightweight lighting fixture positively docks by
plugging in with a 20° locking twist.
High-efficiency optical system maximizes light output while minimizing glare.
Starter component is externally accessible for easy maintenance and is fully
encapsulated for long life.
Star Friendly™ cutoff distribution patterns available.
Wildlife shield is cast into the docking station (not a separate piece) and is
easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms.
Cam-latch door frame allows easy re-lamping without tools.
Optional (BZ) finish shown
Large surface area "breathing seal" gasket, seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture.
Applications:
Roadways
Residential areas
Coastal areas — salt/corrosive environments
Parking lots
Storage areas
Photocontrol receptacle is adjustable without tools.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
E39 mogul base socket standard.
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
Optical chamber is IP64 rated standard.
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
26 1/2''
(673)
9.2"
(234)
12 1/2''
(318)
26.5"
(673)
9''
(228)
12.5"
(318)
Vertical Tenon Mount
9.2"
(234)
Effective Projected Area (EPA)
The EPA for the DuraStar™ is .56 sq. ft.
The EPA for the DuraStar™ sag lens, is .70 sq. ft.
Approx. Wt. = 14 lbs.
10
Product Guide
26.5"
(673)
For photometric information, visit our website,
www.americanelectriclighting.com
DuraStar™ Series 20
Roadway Lighting System
35-150W HPS, 100-175W MV/MH
O R D E R I N G
I N F O R M AT I O N
Example: 2 0 1 0 S R N 1 2 0 R 3 F G L C P C
Wattage / Source
Series
20 DuraStar
Cobrahead
03
05
07
10
15
17
35W
50W
70W
100W
150W
175W
Voltage
Distribution
120V
208V
220V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual Tap 120/240
wired 120V
DT2 Dual Tap 120/240
wired 240V
DT3 Dual Tap 240/480
wired 240V
DT4 Dual Tap 240/480
wired 480V
R2 Roadway Type II
R3 Roadway Type III
Ballast
S HPS
M MH
V MV
Refer to the ballast matrix on
page 54 for compatibility.
RN
Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
MR Mag Reg (3 Coil)
XX No Ballast
120
208
220
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
Options
Refer to Optic Distribution
Matrix below for compatibility
Optics
SA Sag Acrylic Lens
SP Sag Polycarbonate Lens
FG Flat Glass Clear Tempered
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Mounting
(blank) DuraLock Docking Station set
for 1-1/4” mast arm
M2
2-bolt Internal 2” setting, for
DuraLock Docking Station
for 2” mast arm
ML
Less DuraLock Docking Station
VT
Vertical Tenon Docking Station
Paint
(blank)
BZ
Gray (standard)
Bronze
Starter3
(blank) Encapsulated plug-in4
SN
No Ignitor (using self-igniting lamp)
Misc.
PC
PK
SS
PL
Listing
UL
CS
UL Listed
CSA Certified
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
NR
No Photocontrol Receptacle1
PB
Phosphor Bronze Contacts
Lamp
LC
LD
LG
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Self-Igniting Lamp2
5H
NN
SH
LCU
Notes:
1
2
3
4
5
Photocontrol Included per
Voltage Specified
Package (includes lamp,
photocontrol, 5’ supply-wire,
mast arm, hardware)
Stainless Steel Fasteners
(external)
Distribution Pattern
Indicator Label
50 Hertz Ballast Cycle5
No NEMA Label on Housing
Shorting Cap
Low Copper Alloy Content
Docking Station (less than 1%)
PB, PC, SH not available with NR option
Requires SN option
HPS only
Externally mounted
Limited availability, please contact your local
American Electric Lighting representative
Optic Distribution
03S
07S
10S
15S
17M
17V
See pages 259-264 for a complete listing
of Frequently Ordered Products
R2SA
◆
◆
◆
-
R3SA
◆
◆
◆
-
R2SP
◆
◆
◆
◆
◆
◆
R3SP
◆
◆
◆
◆
◆
◆
R2FG
◆
◆
◆
◆
-
R3FG
◆
◆
◆
◆
-
Product Guide
11
DuraStar™ Series 30
Roadway Lighting System
200-400W HPS, 400W MV/MH
P R O D U C T
O V E R V I E W
Features:
Revolutionary DuraLock™ docking system provides modular installation and
interchangeability for easy maintenance. Rugged die-cast, powder-coated
docking station mounts securely to mast-arm to ensure secure wiring and
long-lasting stability. Durable lightweight lighting fixture positively docks by
plugging in with a 20° locking twist.
High-efficiency optical system maximizes light output while minimizing
objectionable glare.
Star Friendly™ cutoff distribution patterns available.
Starter component is externally accessible for easy maintenance and is fully
encapsulated for long life.
Wildlife shield is cast into the docking station (not a separate piece) and is
easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms.
Die-cast trigger latch on door frame enables easy and secure one-hand
opening for re-lamping and maintenance.
Large surface area "breathing seal" gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture.
Applications:
Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks
Photocontrol receptacle is adjustable without tools.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
E39 mogul base socket standard.
Suitable for -30°C MH & MV / -40°C HPS.
Optical chamber is IP64 rated standard.
DIMENSIONS
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
36 -1/4"
(921)
36 -1/4
(921)
17-1/2"
(445)
17-1/2"
(445)
11"
(279)
10"
(254)
Vertical Tenon Mount
36 -1/4"
(921)
Effective Projected Area (EPA)
The EPA for the DuraStar™ Series 30 is 1.24 sq. ft. flat glass
The EPA for the DuraStar™ Series 30 is 1.43 sq. ft. sag glass
Approx. Wt. = 30 lbs.
12
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
DuraStar™ Series 30
Roadway Lighting System
200-400W HPS, 400W MV/MH
O R D E R I N G
I N F O R M AT I O N
Example: 3 0 2 5 S C A M T 1 R 3 F G L C P C
Wattage / Source
Series
30 DuraStar
Cobrahead
20
25
31
40
23
200W
S HPS
250W
M MH
310W
V MV
400W
250/400W
wired 250W
24 250/400W
wired 400W
Refer to the ballast matrix on
page 54 for compatibility.
Voltage
Ballast
RN
Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
MR Mag Reg (3 Coil)
XX No Ballast
120
208
220
240
277
347
480
MT1
MT2
MT7
TT1
TT7
TT3
DT1
120V
208V
220V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual Tap 120/240
wired 120V
DT2 Dual Tap 120/240
wired 240V
DT3 Dual Tap 240/480
wired 240V
DT4 Dual Tap 240/480
wired 480V
Distribution
R2 Roadway Type II
R3 Roadway Type III
Refer to Optic
Distribution Matrix
below for compatibility
Optics
SG Sag Glass Clear Tempered
FG Flat Glass Clear Tempered
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Mounting
(blank) DuraLock Docking Station set
for 1-1/4” mast arm
M2
2-bolt Internal 2” setting, for
DuraLock Docking Station
ML
Less DuraLock Docking Station
VT
Vertical Tenon Docking Station
Color
(blank)
BZ
Listing
UL
CS
Gray (standard)
Bronze
UL Listed
CSA Certified
Lamp
LC
LD
LG
Starter3
(blank) Encapsulated Plug-In4
OB Open Board Internal
SN No Ignitor (using self-igniting lamp)
Misc.
PC
SS
PL
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
NR
No Photocontrol Receptacle1
PB
Phosphor Bronze Contacts
Notes:
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Self-Igniting Lamp2
5H
NN
SH
LCU
1
2
3
4
5
PB, PC, SH not available with NR option
Requires SN option
Available in HPS only
Externally mounted
Limited availability, please contact your local
American Electric Lighting representative
Optic Distribution
Photocontrol Included per
Voltage Specified
Stainless Steel Fasteners
(external)
Distribution Pattern
Indicator Label
50 Hertz Ballast Cycle5
No NEMA Label on Housing
Shorting Cap
Low Copper Alloy Content
Docking station (less than 1%)
See pages 259-264 for a complete listing
of Frequently Ordered Products
20S
25S
31S
40S
17M
25M
40M
17V
25V
40V
R2SG R3SG R2FG R3FG
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
Product Guide
13
Roadway Series 115
Roadway Lighting Luminaires — Cobrahead
35-400W HPS, 100-250W MV/MH
P R O D U C T
O V E R V I E W
Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance.
Two-bolt mast arm mount provides easy, secure installation and adjustability
for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Optional four-bolt
mounting provides extra security in high-vibration applications.
Die-cast trigger latch on door frame enables easy and secure one-hand
opening for re-lamping and maintenance.
Large surface area "breathing seal" gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture.
Wildlife shield is cast into the housing (not a separate piece) on the two-bolt
unit and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms.
Photocontrol receptacle is adjustable without tools.
Anodized aluminum reflectors provide uniform lighting distribution with
borosilicate glass, acrylic, or polycarbonate refractor.
Applications:
Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks
NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
E39 mogul base socket standard.
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17
10.1"
(257)
27"
(686)
10.1"
(257)
13"
(330)
Effective Projected Area (EPA)
The EPA for the Horizontal Luminaire Series 115 is 0.9 sq. ft.
Approx. Wt. = 19 lbs.
14
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Roadway Series 115
Roadway Lighting Luminaires — Cobrahead
35-400W HPS, 100-250W MH/MV
O R D E R I N G
I N F O R M AT I O N
Example: 1 1 5 1 5 S R N 1 2 0 R 2 D G L C P C
Series
115 Single Door
Cobrahead
Ballast
Wattage / Source
03
05
07
10
13
14
15
17
20
25
40
35W
50W
70W
100W
100/150W
wired 100W
100/150W
wired 150W
150W
175W
200W
250W
400W
S
M
V
HPS
MH
MV
Refer to the ballast matrix on
page 55 for compatibility.
RN
Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
MR Mag Reg (3 Coil)
XX No Ballast
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Mounting
(blank) 2-bolt Internal 1-1/4” setting
(standard)
EF
External Fitter (2-bolt only)
4B
4-bolt Internal
M2
2-bolt Internal 2” setting
E2
External Fitter 2” Mast Arm
(2-bolt only)
Paint1
(blank)
BK
BZ
WH
UP
Gray (standard)
Black
Bronze
White
Unpainted
Terminal Block
(blank) Terminal Block (standard)
T2
Wired to L1 to L2 Position
T3
3 Wire Operation
(L1, N, L2 Position)
Lamp
LC
LD
LG
UL Listed
CSA Certified
Fusing2
SF
Single Fuse (120, 277, 347V)
DF
Double Fuse (208, 220, 240, 480V)
BL
SS
CF
PL
5H
NN
SH
HK
LCU
BF
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR
No Photocontrol Receptacle3
PB
Phosphor Bronze Contacts
120V
208V
220V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual Tap 120/240
wired 120V
DT2 Dual Tap 120/240
wired 240V
DT3 Dual Tap 240/480
wired 240V
DT4 Dual Tap 240/480
wired 480V
R2
R3
RX
Roadway Type II
Roadway Type III
Roadway Type II
4-way
Refer to Optic Distribution
Matrix below for compatibility
Optics
DA
DP
DG
Drop Acrylic
Prismatic Refractor
Drop Polycarbonate
Prismatic Refractor
Drop Glass
Prismatic Refractor
Notes:
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Self-Igniting Lamp4
1
Open Board (standard)
Encapsulated Plug-in
Open Plug-in
External Encapsulated Plug-in
No Ignitor (using self-igniting lamp)
3
4
5
6
7
Misc.
PC
LA
Listing
UL
CS
120
208
220
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
2
Starter5
(blank)
EC
OP
ES
SN
Distribution
Voltage
Photocontrol Included per
Voltage Specified
Bubble Level
Stainless Steel Fasteners
(external)
Charcoal Filter
Distribution Pattern
Indicator Label
Lightning Arrestor
(Void UL/CSA Certified Options)
50 Hertz Ballast Cycle6
No NEMA Label on Housing
Shorting Cap
Hinge Keeper
Low Copper Alloy Content
(less than 1%)
Bridge Fitter7
Other colors available, please contact your local
American Electric Lighting representative
Voids UL/CSA Certified Options and not available in
MT, TT, DT voltages
PB, SH, and PC not available with NR option
Requires SN option
For HPS products only
Limited availability, please contact your local
American Electric Lighting representative
Tested to withstand 3G vibration, 4B option required
Optic Distribution
03S
05S
07S
10S
15S
20S
25S
40S
17M
25M
17V
25V
See pages 259-264 for a complete listing
of Frequently Ordered Products
R2DA R3DA R2DP R3DP R2DG R3DG RXDG
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
Product Guide
15
Roadway Series 115
Roadway Lighting Luminaires — Cutoff Style Cobrahead
35-250W HPS, 100-250W MV/MH
P R O D U C T
O V E R V I E W
Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance.
Two-bolt mast arm mount provides easy, secure installation and adjustability
for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Optional four-bolt
mounting provides extra security in high-vibration applications.
Die-cast trigger latch on door frame enables easy and secure one-hand
opening for re-lamping and maintenance.
Star Friendly™ cutoff distribution patterns available.
Large surface area "breathing seal" gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture.
Wildlife shield is cast into the housing (not a separate piece) on the two-bolt
unit and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms.
Photocontrol receptacle is adjustable without tools.
Anodized aluminum reflectors provide uniform lighting distribution with either
flat or sag clear tempered glass.
Applications:
Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks
NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
E39 mogul base socket standard.
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17 Specs
27"
(686)
6.5"
(165)
13"
(330)
13"
(330)
6.5"
(165)
8.3"
(211)
Effective Projected Area (EPA)
The EPA for the Horizontal Luminaire Series 115 with cutoff is .74 sq. ft.
Approx. Wt. = 19 lbs.
16
Product Guide
27"
(686)
8.3"
(211)
Effective Projected Area (EPA)
The EPA for the Horizontal Luminaire Series 115 with sag glass is .82 sq. ft.
For photometric information, visit our website,
www.americanelectriclighting.com
Roadway Series 115
Roadway Lighting Luminaires — Cutoff Style Cobrahead
35-250W HPS, 100-250W MH/MV
O R D E R I N G
I N F O R M AT I O N
Example: 1 1 5 1 5 S C A M T 1 R 3 F G L C P C H P
Wattage / Source
Series
115 Single Door
Cobrahead
03
05
07
10
13
14
15
17
20
25
35W
50W
70W
100W
100/150W
wired 100W
100/150W
wired 150W
150W
175W
200W
250W
S
M
V
HPS
MH
MV
Refer to the ballast matrix on
page 55 for compatibility.
RN
Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
MR Mag Reg (3 Coil)
XX No Ballast
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Mounting
(blank) 2-bolt Internal 1-1/4” setting
(standard)
EF
External Fitter (2-bolt only)
4B
4-bolt Internal
M2
2-bolt Internal 2” setting
E2
External Fitter 2” Mast Arm
(2-bolt only)
Paint1
(blank)
BK
BZ
WH
UP
Gray (standard)
Black
Bronze
White
Unpainted
Terminal Block
(blank) Terminal Block (standard)
T2
Wired to L1 & L2 Positions
T3
3 Wire Operation
(L1, N, L2 Position)
Listing
UL
CS
UL Listed
CSA Certified
Fusing2
SF
Single Fuse (120, 277, 347V)
DF
Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR
No Photocontrol Receptacle3
PB
Phosphor Bronze Contacts
Lamp
LC
LD
LG
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Self-Igniting Lamp4
Starter5
(blank)
EC
OP
ES
SN
Open Board (standard)
Encapsulated Plug-in
Open Plug-in
External Encapsulated Plug-in
No Ignitor (using self-igniting lamp)
Misc.
PC
BL
SS
CF
PL
LA
5H
NN
SH
HK
HP
LCU
BF
Voltage
Ballast
Distribution
120
208
220
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
120V
208V
220V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual Tap 120/240
wired 120V
DT2 Dual Tap 120/240
wired 240V
DT3 Dual Tap 240/480
wired 240V
DT4 Dual Tap 240/480
wired 480V
R2
R3
Roadway Type II
Roadway Type III
Refer to Optic Distribution
Matrix below for compatibility
Optics
FG
SG
Flat Glass Clear Tempered
Sag Glass Clear Tempered
Notes:
1
2
3
4
5
6
7
8
Other colors available, please contact your local
American Electric Lighting representative
Voids UL/CSA Certified Options; not available in
MT, TT, DT voltages
PB, PC, and SH not available with NR option
Requires SN option
For HPS products only
Limited availability, please contact your local
American Electric Lighting representative
FG optics only
Tested to withstand 3G vibration, 4B option required
Optic Distribution
Photocontrol Included per
Voltage Specified
Bubble Level
Stainless Steel Fasteners (external)
Charcoal Filter
Distribution Pattern
Indicator Label
Lightning Arrestor
(Void UL/CSA Certified Options)
50 Hertz Ballast Cycle6
No NEMA Label on Housing
Shorting Cap
Hinge Keeper
High Performance7
Low Copper Alloy Content
(less than 1%)
Bridge Fitter8
03S
05S
07S
10S
15S
20S
25S
17M
25M
17V
25V
R2 SG
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
R3 SG
◆
◆
◆
◆
◆
◆
◆
◆
◆
R2 FG
◆
◆
◆
◆
◆
◆
◆
◆1
◆1
◆1
◆1
R3 FG
◆
◆
◆
◆
◆
◆1
◆1
◆1
◆1
R2 FG HP
◆
◆
◆
◆
◆
-
R3 FG HP
◆
◆
◆
◆
◆
-
Notes:
1 Use deluxe/coated lamp LD option
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
17
Roadway Series 315
Roadway Lighting Luminaires — Cobrahead with Power Door
35-400W HPS, 100-250W MV/MH
P R O D U C T
O V E R V I E W
Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance.
Die-cast secondary Power Pad door places all electrical components on one
easily interchangeable module with quick disconnects to main fixture housing.
Two-bolt mast arm mount provides easy, secure installation and adjustability
for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Optional four-bolt
mounting provides extra security in high-vibration applications.
Die-cast trigger latch on lens frame enables easy and secure one-hand
opening for re-lamping.
Large surface area "breathing seal" gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture.
Wildlife shield is cast into the housing (not a separate piece) on the two-bolt
unit and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms.
Photocontrol receptacle is adjustable without tools.
Applications:
Anodized aluminum reflectors provide uniform lighting distribution with
borosilicate glass, acrylic or polycarbonate refractor.
Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks
NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
E39 mogul base socket standard.
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31
10.1"
(257)
27"
(686)
10.1"
(257)
13"
(330)
Effective Projected Area (EPA)
The EPA for the Horizontal Luminaire Series 315 is 0.9 sq. ft.
Approx. Wt. = 19 lbs.
18
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Roadway Series 315
Roadway Lighting Luminaires — Cobrahead with Power Door
35-400W HPS, 100-250W MV/MH
O R D E R I N G
I N F O R M AT I O N
Example: 3 1 5 1 0 S M R D T 2 R 3 D G N R B L
Wattage / Source
Series
315 Power Door
Cobrahead
03
05
07
10
13
35W
S HPS
50W
M MH
70W
V MV
100W
100/150W
wired 100W
14 100/150W
wired 150W
15 150W
17 175W
20 200W
25 250W
40 400W
Refer to the ballast matrix on
page 56 for compatibility.
Voltage
Ballast
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
MR Mag Reg (3 Coil)
XX No Ballast
Options
Distribution
R2 Roadway Type II
120V
R3 Roadway Type III
208V
RX Roadway Type II
220V
4-way
240V
277V
Refer to Optical Matrix
347V
below for compatibility
480V
Multi-tap wired 120V
Multi-tap wired 208V
Optics
Multi-tap wired 240V
Multi-tap wired 277V
DA Drop Acrylic
Tri-tap wired 120V
Prismatic Refractor
Tri-tap wired 277V
DP Drop Polycarbonate
Tri-tap wired 347V
Prismatic Refractor
Dual Tap 120/240
DG Drop Glass
wired 120V
Prismatic Refractor
DT2 Dual Tap 120/240
wired 240V
DT3 Dual Tap 240/480
wired 240V
DT4 Dual Tap 240/480
wired 480V
120
208
220
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Mounting
(blank) 2-bolt Internal 1-1/4” setting
(standard)
EF External Fitter (2-bolt only)
4B 4-bolt Internal
M2 2-bolt Internal 2” setting
E2 External Fitter 2” Mast Arm
(2-bolt only)
Paint1
(blank)
BK
BZ
WH
UP
Gray (standard)
Black
Bronze
White
Unpainted
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation
(L1, N, L2 Position)
Listing
UL
CS
UL Listed
CSA Certified
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle3
PB Phosphor Bronze Contacts
Lamp
LC
LD
LG
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Self Igniting Lamp4
Starter5
(blank)
EC
OP
SN
Open Board (standard)
Encapsulated Plug-in
Open Plug-in
No Ignitor4
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
1 Other colors available, please contact your local
American Electric Lighting representative
2 Voids UL/CSA Certified Options, not available in
MT, TT, DT voltages
3 PB, SH, PC not available with with NR option
4 Requires SN option
5 Available in HPS only
6 Limited availability, please contact your local
American Electric Lighting representative
7 Tested to withstand 3G vibration, 4B option required
Optic Distribution
Misc.
PC
BL
SS
CF
PL
LA
Fusing2
SF
DF
Notes:
5H
NN
SH
LCU
HK
BF
Photocontrol Included per
Voltage Specified
Bubble Level
Stainless Steel Fasteners (external)
Charcoal Filter
Distribution Pattern
Indicator Label
Lightning Arrestor
(Void UL/CSA Certified Options)
50 Hertz Ballast Cycle6
No NEMA Label on Housing
Shorting Cap
Low Copper Alloy Content
(less than 1%)
Hinge Keeper
Bridge Fitter7
03S
05S
07S
10S
15S
20S
25S
31S
40S
17M
25M
17V
25V
See pages 259-264 for a complete listing
of Frequently Ordered Products
R2DA R3DA R2DP R3DP R2DG R3DG RXDG
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
Product Guide
19
Roadway Series 315
Roadway Lighting Luminaires — Cutoff Style Cobrahead with Power Door
35-400W HPS, 100-250W MV/MH
P R O D U C T
O V E R V I E W
Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance. Die-cast secondary Power Pad door places all electrical
components on one easily interchangeable module with quick disconnects to
main fixture housing.
Two-bolt mast arm mount provides easy, secure installation and adjustability
for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Optional four-bolt mounting
provides extra security in high-vibration applications.
Die-cast trigger latch on lens frame enables easy and secure one-hand
opening for re-lamping.
Star Friendly™ cutoff distribution patterns available.
Large surface area “breathing seal” gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture.
Wildlife shield is cast into the housing (not a separate piece) on the two-bolt
unit and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms.
Applications:
Photocontrol receptacle is adjustable without tools.
Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks
Anodized aluminum reflectors provide uniform lighting distribution with either
flat or sag clear tempered glass.
NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
E39 mogul socket standard.
DIMENSIONS
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31
Suitable for -30°C MH & MV / -40°C HPS.
6.5"
(165)
27"
(686)
6.5"
(165)
13"
(330)
Effective Projected Area (EPA)
The EPA for the Horizontal Luminaire Series 315
with Cutoff is 0.98 sq. ft.
Approx. Wt. = 19 lbs.
20
Product Guide
27"
(686)
13"
(330)
8.3"
(211)
Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 315
with sag glass is 1.06 sq. ft.
For photometric information, visit our website,
www.americanelectriclighting.com
Roadway Series 315
Roadway Lighting Luminaires — Cutoff Style Cobrahead with Power Door
35-400W HPS, 100-250W MV/MH
O R D E R I N G
I N F O R M AT I O N
Example: 3 1 5 1 0 S C A D T 2 R 3 F G N R H P
Wattage / Source
Series
315 Power Door
Cobrahead
03
05
07
10
13
35W
S HPS
50W
M MH
70W
V MV
100W
100/150W
wired 100W
14 100/150W
wired 150W
15 150W
17 175W
20 200W
25 250W
40 400W
Refer to the ballast matrix on
page 56 for compatibility.
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
MR Mag Reg (3 Coil)
XX No Ballast
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Mounting
(blank) 2-bolt Internal 1-1/4” setting
(standard)
EF External Fitter (2-bolt only)
4B 4-bolt Internal
M2 2-bolt Internal 2” setting
E2 External Fitter 2” Mast Arm
(2-bolt only)
Paint1
(blank)
BK
BZ
WH
UP
Gray (standard)
Black
Bronze
White
Unpainted
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation
(L1, N, L2 Position)
Listing
UL
CS
UL Listed
CSA Certified
Fusing2
SF
DF
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle3
PB Phosphor Bronze Contacts
Lamp
LC
LD
LG
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Self-Igniting Lamp4
Starter5
(blank)
EC
OP
SN
Open Board (standard)
Encapsulated Plug-in
Open Plug-in
No Ignitor (use self-igniting lamp)
Misc.
PC
BL
SS
CF
PL
LA
5H
NN
SH
LCU
HK
HP
BF
Voltage
Ballast
Distribution
R2 Roadway Type II
120V
R3 Roadway Type III
208V
220V
Refer to Optical Matrix
240V
below for compatibility
277V
347V
480V
Multi-tap wired 120V
Optics
Multi-tap wired 208V
Multi-tap wired 240V
FG Flat Glass Clear Tempered
Multi-tap wired 277V
SG Sag Glass Clear Tempered
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual Tap 120/240
wired 120V
DT2 Dual Tap 120/240
wired 240V
DT3 Dual Tap 240/480
wired 240V
DT4 Dual Tap 240/480
wired 480V
120
208
220
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
Notes:
Photocontrol Included per
Voltage Specified
Bubble Level
Stainless Steel Fasteners (external)
Charcoal Filter
Distribution Pattern
Indicator Label
Lightning Arrestor
(Void UL/CSA Certified Options)
50 Hertz Ballast Cycle6
No NEMA Label on Housing
Shorting Cap
Low Copper Alloy Content
(less than 1%)
Hinge Keeper
High Performance7
Bridge Fitter8
1 Other colors available, please contact your local
American Electric Lighting representative
2 Voids UL/CSA Certified Options, not available in
MT, TT, DT voltages
3 PB, PC, SH, not available in NR option
4 Requires SN option
5 Available in HPS only
6 Limited availability, please contact your local
American Electric Lighting representative
7 FG Optics only
8 Tested to withstand 3G vibration, 4B option required
Optic Distribution
03S
05S
07S
10S
15S
20S
25S
40S
17M
25M
17V
25V
R2SG R3SG R2FG R3FG
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆1
◆1
◆
◆1
◆1
◆
◆1
◆1
◆
◆1
◆1
R2FGHP
◆
◆
◆
◆
◆
R3FGHP
◆
◆
◆
◆
◆
Notes:
1 Use deluxe/coated lamp LD option
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
21
Roadway Series 125
Roadway Lighting Luminaires — Cobrahead
200-400W HPS, 175-400W MH/MV
P R O D U C T
O V E R V I E W
Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance.
Optional two-bolt mast arm mount provides easy, secure installation and
adjustability for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Standard fourbolt mounting provides extra security in high-vibration applications.
Die-cast trigger latch on door frame enables easy and secure one-hand
opening for re-lamping and maintenance.
Large surface area "breathing seal" gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture.
Wildlife shield is cast into the housing (not a separate piece) with 2B option
and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms.
Photocontrol receptacle is adjustable without tools.
Anodized aluminum reflectors provide uniform lighting distribution with either
borosilicate glass, or polycarbonate refractor.
Applications:
Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks
NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
E39 mogul socket standard.
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31
DIMENSIONS
Suitable for -30°C MH & MV / -40°C HPS.
14"
(356)
31-1/2"
(800)
14"
(356)
14-3/4"
(375)
Effective Projected Area (EPA)
The EPA for the Horizontal Luminaire series 125 is 1.30 sq. ft.
Approx. Wt. = 35 lbs.
22
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Roadway Series 125
Roadway Lighting Luminaires — Cobrahead
200-400W HPS, 175-400W MH/MV
O R D E R I N G
I N F O R M AT I O N
Example: 1 2 5 4 0 S C A M T 1 R 3 D G L C P C
Wattage / Source
Series
125 Single Door
Cobrahead
17
20
25
31
40
23
175W
200W
250W
310W
400W
250/400W
wired 250
24 250/400W
wired 400
S HPS
M MH
V MV
Refer to the ballast matrix on
page 56 for compatibility.
Voltage
Ballast
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
MR Mag Reg (3 Coil)
XX No Ballast
Distribution
R2 Roadway Type II
120V
R3 Roadway Type III
208V
R4 Roadway Type IV
220V
240V
Refer to Optical Matrix
277V
below for compatibility
347V
480V
Optics
Multi-tap wired 120V
Multi-tap wired 208V
DP Drop Polycarbonate
Multi-tap wired 240V
Prismatic Refractor
Multi-tap wired 277V
DG Drop Glass
Tri-tap wired 120V
Prismatic Refractor
Tri-tap wired 277V
Tri-tap wired 347V
Dual Tap 120/240
wired 120V
DT2 Dual Tap 120/240
wired 240V
DT3 Dual Tap 240/480
wired 240V
DT4 Dual Tap 240/480
wired 480V
120
208
220
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Mounting
(blank) 4-bolt Internal (standard)
M2 2-bolt Internal 2” setting
2B 2-bolt Internal 1-1/4” setting
Lamp
LC
LD
LG
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Self-Igniting Lamp4
Paint1
(blank)
BK
BZ
WH
UP
Starter5
(blank)
EC
OP
SN
Open Board (standard)
Encapsulated Plug-in
Open Plug-in
No Ignitor (use self-igniting lamp)
Gray (standard)
Black
Bronze
White
Unpainted
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation
(L1, N, L2 Position)
Listing
UL
CS
Fusing2
SF
DF
UL Listed
CSA Certified
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle3
PB Phosphor Bronze Contacts
Misc.
PC
BL
SS
CF
PL
LA
5H
NN
SH
LCU
HK
BF
Photocontrol Included per
Voltage Specified
Bubble Level
Stainless Steel Fasteners (external)
Charcoal Filter
Distribution Pattern
Indicator Label
Lightning Arrestor
(Void UL/CSA Certified Options)
50 Hertz Ballast Cycle6
No NEMA Label on Housing
Shorting Cap
Low Copper Alloy Content
(less than 1%)
Hinge Keeper
Bridge Fitter7
Notes:
1 Other colors available, please contact your local
American Electric Lighting representative
2 Voids UL/CSA Certified Options, not available with
MT, TT, DT voltages
3 PB, PC, SH, not available in NR option
4 Requires SN starter option
5 Available in HPS only
6 Limited availability, please contact your local
American Electric Lighting representative
7 Tested to withstand 3G vibration, 4B standard required
Optic Distribution
20S
25S
31S
40S
17M
25M
40M
17V
25V
40V
See pages 259-264 for a complete listing
of Frequently Ordered Products
R2DP R3DP R2DG R3DG R4DG
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
-
Product Guide
23
Roadway Series 125
Roadway Lighting Luminaires — Cutoff Style Cobrahead
200-400W HPS, 175-400W MV/MH
P R O D U C T
O V E R V I E W
Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance.
Optional two-bolt mast arm mount provides easy, secure installation and
adjustability for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Standard fourbolt mounting provides extra security in high-vibration applications.
Die-cast trigger latch on door frame enables easy and secure one-hand
opening for re-lamping and maintenance.
Star Friendly™ cutoff distribution patterns available.
Large surface area “breathing seal” gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture.
Wildlife shield is cast into the housing (not a separate piece) with 2B option
and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms.
Photocontrol receptacle is adjustable without tools.
Applications:
Anodized aluminum reflectors provide uniform lighting distribution with either
flat or sag clear tempered glass.
Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks
NEMA wattage label, terminal block, and photocontrol receptacle are
standard.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
E39 mogul socket standard.
DIMENSIONS
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31
Suitable for -30°C MH & MV / -40°C HPS.
31-1/2"
(800)
7-3/4"
(197)
14-3/4"
(575)
31-1/2"
(800)
14-3/4"
(575)
7-3/4"
(197)
10"
(254)
Effective Projected Area (EPA)
The EPA for the Horizontal Luminaire series 125 Cutoff is 1.14 sq. ft.
Approx. Wt. = 35 lbs
24
Product Guide
10"
(254)
Effective Projected Area (EPA)
The EPA for the Horizontal Luminaire Series 125 with sag glass is 1.22 sq. ft.
For photometric information, visit our website,
www.americanelectriclighting.com
Roadway Series 125
Roadway Lighting Luminaires — Cutoff Style Cobrahead
200-400W HPS, 175 - 400W MV/MH
O R D E R I N G
I N F O R M AT I O N
Example: 1 2 5 4 0 S C A M T 1 R 3 F G L C P C
Wattage / Source
Series
125 Single Door
Cobrahead
17
20
25
31
40
23
175W
S HPS
200W
M MH
250W
V MV
310W
400W
250/400W
wired 250
24 250/400W
wired 400
Refer to the ballast matrix on
page 56 for compatibility.
Voltage
Ballast
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
MR Mag Reg (3 Coil)
XX No Ballast
Options
Distribution
R2 Roadway Type II
120V
R3 Roadway Type III
208V
220V
Refer to Optical Matrix
240V
below for compatibility
277V
347V
480V
Multi-tap wired 120V
Optics
Multi-tap wired 208V
Multi-tap wired 240V
FG Flat Glass Clear Tempered
Multi-tap wired 277V
SG Sag Glass Clear Tempered
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual Tap 120/240
wired 120V
DT2 Dual Tap 120/240
wired 240V
DT3 Dual Tap 240/480
wired 240V
DT4 Dual Tap 240/480
wired 480V
120
208
220
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Mounting
(blank) 4-bolt Internal (standard)
M2 2-bolt Internal 2” setting
2B 2-bolt Internal 1-1/4” setting
Lamp
LC
LD
LG
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Self-Igniting Lamp4
Paint1
(blank)
BK
BZ
WH
UP
Starter5
(blank)
EC
OP
SN
Open Board (standard)
Encapsulated Plug-in
Open Plug-in
No Ignitor (use self-igniting lamp)
Gray (standard)
Black
Bronze
White
Unpainted
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation
(L1, N, L2 Position)
Listing
UL
CS
Fusing2
SF
DF
UL Listed
CSA Certified
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle3
PB Phosphor Bronze Contacts
Misc.
PC
BL
SS
CF
PL
LA
5H
NN
SH
LCU
HK
HP
BF
Notes:
Photocontrol Included per
Voltage Specified
Bubble Level
Stainless Steel Fasteners (external)
Charcoal Filter
Distribution Pattern
Indicator Label
Lightning Arrestor
(Void UL/CSA Certified Options)
50 Hertz Ballast Cycle6
No NEMA Label on Housing
Shorting Cap
Low Copper Alloy Content
(less than 1%)
Hinge Keeper
High Performance7
Bridge Fitter8
1 Other colors available, please contact your local
American Electric Lighting representative
2 Voids UL/CSA Certified Options, not available with
MT, TT, DT voltages
3 PB, PC, SH, not available in NR option
4 Requires SN starter option
5 Available in HPS only
6 Limited availability, please contact your local
American Electric Lighting representative
7 FG Optics only
8 Tested to withstand 3G vibration, 4B standard required
Optic Distribution
20S
25S
31S
40S
17M
25M
40M
17V
25V
40V
See pages 259-264 for a complete listing
of Frequently Ordered Products
R2SG R3SG R2FG R3FG
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
-
R2 FG HP
◆
◆
◆
◆
-
R3 FG HP
◆
◆
◆
◆
-
Product Guide
25
Roadway Series 325
Roadway Lighting Luminaires — Cobrahead with Power Door
200-400W HPS, 175-400W MV/MH
P R O D U C T
O V E R V I E W
Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance.
Die-cast secondary Power Pad door places all electrical components on one
easily interchangeable module with quick disconnects to main fixture housing.
Optional two-bolt mast arm mount provides easy, secure installation and
adjustability for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Standard
four-bolt mounting provides extra security in high-vibration applications.
Die-cast trigger latch on lens frame enables easy and secure one-hand
opening for re-lamping.
Large surface area “breathing seal” gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture.
Wildlife shield is cast into the housing (not a separate piece) with 2B option
and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms.
Applications:
Photocontrol receptacle is adjustable without tools.
Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks
Anodized aluminum reflectors provide uniform lighting distribution with either
borosilicate glass or polycarbonate refractor.
NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
DIMENSIONS
E39 mogul socket standard.
Suitable for -30°C MH & MV / -40°C HPS.
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31
14"
(356)
31-1/2"
(800)
14"
(356)
14-3/4"
(375)
Effective Projected Area (EPA)
The EPA for the Horizontal Luminaire Series 325 is 1.30 sq. ft.
Approx. Wt. = 35 lbs.
26
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Roadway Series 325
Roadway Lighting Luminaires — Cobrahead with Power Door
200-400W HPS, 175-400W MV/MH
O R D E R I N G
I N F O R M AT I O N
Example: 3 2 5 4 0 M C A M T 7 R 3 D G B K L C
Series
325 Power Door
Cobrahead
Wattage / Source
17
20
25
31
40
23
175W
S HPS
200W
M MH
250W
V MV
310W
400W
250/400W
wired 250W
24 250/400W
wired 400W
Refer to the ballast matrix on
page 57 for compatibility.
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
XX No Ballast
SC SCWA
MR Mag Reg (3 Coil)
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Mounting
(blank) 4-bolt Internal (standard)
M2 2-bolt Internal 2” setting
2B 2-bolt Internal 1-1/4”
setting
Paint1
(blank)
BK
BZ
WH
UP
Gray (standard)
Black
Bronze
White
Unpainted
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation
(L1, N, L2 Position)
Listing
UL
CS
UL Listed
CSA Certified
Fusing2
SF
DF
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Lamp
LC
LD
LG
Lamp Included, Clear
Lamp Included Deluxe/Coated
Self-Igniting Lamp4
Starter5
(blank)
EC
OP
SN
Open Board (standard)
Encapsulated Plug-in
Open Plug-in
No Ignitor (use self-igniting lamp)
Misc.
PC
BL
SS
CF
PL
LA
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle3
PB Phosphor Bronze Contacts
5H
NN
SH
LCU
HK
BF
Voltage
Ballast
Distribution
R2 Roadway Type II
120V
R3 Roadway Type III
208V
R4 Roadway Type IV
220V
240V
Refer to Optical Matrix
277V
below for compatibility
347V
480V
Optics
Multi-tap wired 120V
Multi-tap wired 208V
DP Drop Polycarbonate
Multi-tap wired 240V
Prismatic Refractor
Multi-tap wired 277V
DG Drop Glass
Tri-tap wired 120V
Prismatic Refractor
Tri-tap wired 277V
Tri-tap wired 347V
Dual Tap 120/240
wired 120V
DT2 Dual Tap 120/240
wired 240V
DT3 Dual Tap 240/480
wired 240V
DT4 Dual Tap 240/480
wired 480V
120
208
220
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
Notes:
Photocontrol Included per
Voltage Specified
Bubble Level
Stainless Steel Fasteners (external)
Charcoal Filter
Distribution Pattern
Indicator Label
Lightning Arrestor
(Void UL/CSA Certified Options)
50 Hertz Ballast Cycle6
No NEMA Label on Housing
Shorting Cap
Low Copper Alloy Content
(less than 1%)
Hinge Keeper
Bridge Fitter7
1 Other colors available, please contact your local
American Electric Lighting representative
2 Voids UL/CSA Certified Options; not available with
MT, TT, DT voltages
3 PB, PC, SH, not available in NR option
4 Requires SN starter option
5 Available in HPS only
6 Limited availability, please contact your local
American Electric Lighting representative
7 Tested to withstand 3G vibration, 4B standard required
Optic Distribution
20S
25S
31S
40S
17M
25M
40M
17V
25V
40V
See pages 259-264 for a complete listing
of Frequently Ordered Products
R2DP R3DP R2DG R3DG R4DG
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
-
Product Guide
27
Roadway Series 325
Roadway Lighting Luminaires — Cutoff Style Cobrahead with Power Door
200-400W HPS, 175-250W MV/MH
P R O D U C T
O V E R V I E W
Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance.
Die-cast secondary Power Pad door places all electrical components on one
easily interchangeable module with quick disconnects to main fixture housing.
Optional two-bolt mast arm mount provides easy, secure installation and
adjustability for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Standard
four-bolt mounting provides extra security in high-vibration applications.
Die-cast trigger latch on lens frame enables easy and secure one-hand
opening for re-lamping.
Star Friendly™ cutoff distribution patterns available.
Large surface area “breathing seal” gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture.
Wildlife shield is cast into the housing (not a separate piece) with 2B option
and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms.
Applications:
Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks
Photocontrol receptacle is adjustable without tools.
Anodized aluminum reflectors provide uniform lighting distribution with either
flat or sag clear tempered glass.
NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
DIMENSIONS
E39 mogul socket standard.
Suitable for -30°C MH & MV / -40°C HPS.
7-3/4"
(197)
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31
31-1/2"
(800)
7-3/4"
(197)
31-1/2"
(800)
14-3/4"
(375)
10"
(254)
Effective Projected Area (EPA)
The EPA for the Horizontal Luminaire Series 325 is 1.14 sq. ft.
Approx. Wt. = 35 lbs
28
Product Guide
Effective Projected Area (EPA) The EPA for the Horizontal Luminaire
Series 325 with sag glass is 1.22 sq. ft.
For photometric information, visit our website,
www.americanelectriclighting.com
14-3/4"
(575)
10"
(254)
Roadway Series 325
Roadway Lighting Luminaires — Cutoff Style Cobrahead with Power Door
200-400W HPS, 175-250W MV/MH
O R D E R I N G
I N F O R M AT I O N
Example: 3 2 5 3 1 S C A M T 1 R 3 F G S F B L
Wattage / Source
Series
325 Power Door
Cobrahead
17
20
25
31
40
23
175W
200W
250W
310W
400W
250/400W
wired 250W
24 250/400W
wired 400W
S HPS
M MH
V MV
Refer to the ballast matrix on
page 57 for compatibility.
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA
CT CWI
MR Mag Reg (3 Coil)
SC SCWA
XX No Ballast
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Mounting
(blank) 4-bolt Internal (standard)
M2 2-bolt Internal 2” setting
2B 2-bolt Internal 1-1/4”
setting
Paint1
(blank)
BK
BZ
WH
UP
Gray (standard)
Black
Bronze
White
Unpainted
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation
(L1, N, L2 Position)
Listing
UL
CS
UL Listed
CSA Certified
Fusing2
SF
DF
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Lamp
LC
LD
LG
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Self-Igniting Lamp4
Starter5
(blank)
EC
OP
SN
Open Board (standard)
Encapsulated Plug-in
Open Plug-in
No Ignitor (use self-igniting lamp)
Misc.
PC
BL
SS
CF
PL
LA
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle3
PB Phosphor Bronze Contacts
5H
NN
SH
LCU
HK
HP
BF
Voltage
Ballast
Distribution
R2 Roadway Type II
120V
R3 Roadway Type III
208V
220V
Refer to Optical Matrix
240V
below for compatibility
277V
347V
480V
Optics
Multi-tap wired 120V
Multi-tap wired 208V
FG Flat Glass Clear Tempered
Multi-tap wired 240V
SG Sag Glass Clear Tempered
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual Tap 120/240
wired 120V
DT2 Dual Tap 120/240
wired 240V
DT3 Dual Tap 240/480
wired 240V
DT4 Dual Tap 240/480
wired 480V
120
208
220
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
Notes:
Photocontrol Included per
Voltage Specified
Bubble Level
Stainless Steel Fasteners (external)
Charcoal Filter
Distribution Pattern
Indicator Label
Lightning Arrestor
(Void UL/CSA Certified Options)
50 Hertz Ballast Cycle6
No NEMA Label on Housing
Shorting Cap
Low Copper Alloy Content
(less than 1%)
Hinge Keeper
High Performance7
Bridge Fitter8
1 Other colors available, please contact your local
American Electric Lighting representative
2 Voids UL/CSA Certified Options; not available with
MT, TT, DT voltages
3 PB, PC, SH, not available in NR option
4 Requires SN option
5 Available in HPS only
6 Limited availability, please contact your local
American Electric Lighting representative
7 Available with FG optics only
8 Tested to withstand 3G vibration, 4B standard required
Optic Distribution
20S
25S
31S
40S
17M
25M
40M
17V
25V
40V
See pages 259-264 for a complete listing
of Frequently Ordered Products
R2SG R3SG R2FG R3FG
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
-
R2 FG HP R3 FG HP
◆
◆
◆
◆
◆
◆
◆
◆
-
Product Guide
29
Roadway Series 327
Roadway Lighting Luminaires — Cobrahead
310-1000W HPS, 750-1000W MV/MH
P R O D U C T
O V E R V I E W
Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance.
Four-bolt mast arm mount provides easy, secure installation and adjustability
for arms from 1-1/4" to 2" (32mm to 51mm) diameter and extra security in highvibration applications.
Die-cast trigger latch on door frame enables easy and secure one-hand
opening for re-lamping and maintenance.
Large surface area “breathing seal” gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture.
Anodized aluminum reflectors provide uniform lighting distribution with
standard borosilicate glass refractor.
Photocontrol receptacle is adjustable without tools.
NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard.
Applications:
Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
E39 mogul socket standard.
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
16-1/4"
(413)
38.3"
(973)
16-1/4"
(413)
17-1/2"
(445)
Effective Projected Area (EPA)
The EPA for the Horizontal Luminaire Series 327 is 1.96 sq. ft.
Approx. Wt. = 35 lbs
30
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Roadway Series 327
Roadway Lighting Luminaires — Cobrahead
310-1000W HPS, 750-1000W MV/MH
O R D E R I N G
I N F O R M AT I O N
Example: 3 2 7 X 1 M C A M T 1 R 3 D G L C P C
Wattage / Source
Series
327 Single Door
Cobrahead
31 310W
S HPS
40 400W
M MH
75 750W
V MV
X1 1000W
Refer to the ballast matrix on
page 57 for compatibility.
Voltage
Ballast
CA
CT
MR
SC
XX
CWA
CWI
Mag Reg (3 Coil)
SCWA
No Ballast
Distribution
120
208
220
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
120V
208V
220V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual Tap 120/240
wired 120V
DT2 Dual Tap 120/240
wired 240V
DT3 Dual Tap 240/480
wired 240V
DT4 Dual Tap 240/480
wired 480V
R1
R2
R3
R4
Roadway Type I
Roadway Type II
Roadway Type III
Roadway Type IV
Refer to Optical Matrix
below for compatibility
Optics
DG Drop Glass
Prismatic Refractor
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Paint1
(blank)
BK
BZ
WH
UP
Gray (standard)
Black
Bronze
White
Unpainted
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation
(L1, N, L2 Position)
Fusing2
SF
DF
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle3
PB Phosphor Bronze Contacts
Lamp
LC
LD
Misc.
PC
BL
SS
PL
LA
NN
SH
Notes:
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Photocontrol Included per
Voltage Specified
Bubble Level
Stainless Steel Fasteners (external)
Distribution Pattern
Indicator Label
Lightning Arrestor
No NEMA Label on Housing
Shorting Cap
1
2
3
Other colors available, please contact your local
American Electric Lighting representative
Not available with MT, TT, DT voltages
PB, PC, SH not available with NR option
Optic Distribution
31S
40S
X1S
X1V
X1M
R1DG R2DG R3DG R4DG
◆
◆
◆
◆
◆
◆
◆
◆1
◆
◆
◆
-
Notes:
1 Use deluxe/coated lamp LD option
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
31
Roadway Series 413
Roadway Lighting Luminaires — Cobrahead
35-150W HPS
P R O D U C T
O V E R V I E W
Features:
Compact size for economical street lighting.
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance.
Two-bolt mast arm mount provides easy, secure installation and adjustability
for arms from 1-1/4" to 2" (32mm to 51mm) diameter.
Stainless steel latch enables easy one-hand opening for re-lamping and
maintenance.
Star Friendly™ cutoff distribution patterns available.
Large surface area “breathing seal” gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture.
Wildlife shield is cast into the housing (not a separate piece) and is easily
adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms.
Photocontrol receptacle is adjustable without tools.
Applications
Anodized aluminum reflector provides uniform lighting distribution with either
flat lens, drop acrylic, drop polycarbonate, drop glass or sag glass.
Roadways
Residential streets
Storage areas
Parking lots
Campuses
Parks
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
6.830"
(174)
21"
(533)
11.5"
(292)
12.8"
(325.12)
Effective Projected Area (EPA)
The EPA for the Horizontal Luminaire Series 413 Drop lens
is 0.80 sq. ft. (.074 m2).
The EPA for the Horizontal Luminaire Series 413 Flat lens
is 0.61 sq. ft. (.057 m2).
Approx. Wt. = 16 lbs.
32
Product Guide
21"
(533)
Effective Projected Area (EPA)
The EPA for the Series 413 sag lens is .69
For photometric information, visit our website,
www.americanelectriclighting.com
12.8"
(325)
Roadway Series 413
Roadway Lighting Luminaires — Cobrahead
35-150W HPS
O R D E R I N G
I N F O R M AT I O N
Example: 4 1 3 1 5 S R N 1 2 0 R 3 D A L C
Wattage / Source
Series
413 Single Door
Cobrahead
03
05
07
10
15
35W
50W
70W
100W
150W
S HPS
Voltage
Ballast
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XX No Ballast
Distribution
R2 Roadway Type II
R3 Roadway Type III
120 120V
240 240V
Refer to Optical Matrix
below for compatibility
Refer to the ballast matrix on
page 58 for compatibility.
Optics
DA Drop Acrylic
Prismatic Refractor
DP Drop Polycarbonate
Prismatic Refractor
DG Drop Glass
Prismatic Refractor
FG Flat Glass Clear Tempered
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Paint1
(blank)
BK
BZ
WH
UP
Gray (standard)
Black
Bronze
White
Unpainted
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle2
PB Phosphor Bronze Contacts
Lamp
LC
LD
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Misc.
PC
SS
CF
PL
5H
NN
LA
SH
Notes:
Photocontrol Included per
Voltage Specified
Stainless Steel Fasteners (external)
Charcoal Filter
Distribution Pattern
Indicator Label
50 Hertz Ballast Cycle3
No NEMA Label on Housing
Lightning Arrestor
Shorting Cap
1 Other colors available, please contact your local
American Electric Lighting representative
2 PB, PC, SH not available with NR option
3 Limited availability, please contact your local
American Electric Lighting representative
Optic Distribution
03S
05S
07S
10S
15S
See pages 259-264 for a complete listing
of Frequently Ordered Products
R2DA R2DP R2DG R3DG R2FG R3FG
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
Product Guide
33
Multi-Mount™ Series 285
Roadway Lighting Luminaires — Set-Back
200-400W HPS, 250-400W MV/MH
P R O D U C T
O V E R V I E W
Features:
Unique optical design allows set-back of mounting poles away from traffic
areas, still while delivering superior performance.
Light pattern allows exceptional spacing to mounting height ratios, permitting
fewer luminaries per mile.
Anodized aluminum reflector provides uniform lighting distribution with drop
acrylic prismatic refractor.
Adjustable and locking knuckle mount provides for precise and secure aiming
of the luminaire.
Latch on lens frame enables easy and secure one-handed opening for
re-lamping.
Photocontrol receptacle is adjustable without tools.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Suitable for -30°C MH & MV / -40°C HPS.
Applications:
Complies with ANSI: C136.2, C136.10, C136.15, C136.31
Interstate roadways
Broad commercial and residential roadways
Large parking areas
DIMENSIONS
27-1/4"
(692)
3"
(76)
5-1/4"
(133)
17"
(432)
11-1/4"
(286)
Effective Projected Area (EPA)
The EPA for the Multi-Mount™ Luminaire Series 285 is 2.8 sq. ft.
Approx Wt. = 42 lbs
34
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Multi-Mount™ Series 285
Roadway Lighting Luminaires — Set-Back
200-400W HPS, 250-400W MV/MH
O R D E R I N G
I N F O R M AT I O N
Example: 2 8 5 4 0 S C A M T 1 R 3 D A L C
Wattage / Source
Series
285 Multi-Mount
Roadway
S HPS
M MH
V MV
20
25
31
40
23
200W
250W
310W
400W1
250/400W
wired 250
24 250/400W
wired 400
Voltage
Ballast
Refer to the ballast matrix on
page 58 for compatibility.
RN Reactor Normal Power Factor
RH Reactor High Power Factor
XN High Reactance (Lag)
Normal Power Factor
XH High Reactance (Lag)
High Power Factor
CA CWA
CT CWI
MR Mag Reg (3 Coil)
120
208
220
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
DT2
DT3
DT4
120V
208V
220V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual Tap 120/240 wired 120V
Dual Tap 120/240 wired 240V
Dual Tap 240/480 wired 240V
Dual Tap 240/480 wired 480V
Distribution
R3 Roadway
Type III2
Optics
DA Drop Acrylic
Prismatic
Refractor
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Paint3
(blank)
BK
WH
UP
GY
Bronze (standard)
Black
White
Unpainted
Gray
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 and L2 Positions
T3 3 Wire Operation (L1, N, L2
Position)
Fusing4
SF
DF
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle5
PB Phosphor Bronze Contacts
Lamp
LC
LD
LG
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Self-Igniting Lamp6
Starter7
(blank)
EC
OP
SN
Open Board (standard)
Encapsulated Plug-in
Open Plug-in
No Ignitor (use self-igniting lamp)
Misc.
PC
HK
SS
PL
LA
NL
SH
Notes:
1
2
3
4
5
6
7
400 MH requires reduced jacket ED-28 lamp
Distribution depends on tilt angle of fixture
Other colors available, please contact your local
American Electric Lighting representative
Not available with MT, TT, DT voltages
PB, PC, SH not available with NR option
Requires SN option
For HPS only
Photocontrol Included
per Voltage Specified
Hinge Keeper
Stainless Steel Fasteners (external)
Distribution Pattern Indicator Label
Lightning Arrestor
NEMA Label
Shorting Cap
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
35
InterState™ II Series 775
Roadway Lighting Luminaires — Interstate with Contemporary Style
200-400W HPS, 175-400W MH, 250-400W MV
P R O D U C T
O V E R V I E W
Features:
Unique optical design allows set-back of mounting poles away from traffic
areas, while still delivering superior performance.
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance.
Slim profile provides a low E.P.A.
Door is hinged and easily removable for quick maintenance.
Anodized aluminum reflector provides uniform lighting distribution with sag or
flat glass clear tempered refractor.
Adjustable and locking knuckle mount provides for precise and secure aiming
of the luminaire.
Photocontrol receptacle is adjustable without tools.
Easy single fastener closure for fast relamping and optional tool-less access
available.
NEMA wattage label, terminal block, and NEMA photocontrol receptacle are
standard.
Applications:
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Interstate roadways
Expressways
Railway switchyards
Shipping docks
Large parking lots
Suitable for -30°C MH & MV / -40°C HPS.
Complies with ANSI: C136.2, C136.3, C136.10, C136.15, C136.31
DIMENSIONS
17.75"
(451)
7"
(178)
23"
(584)
2"
(51)
19.5"
(495)
7"
(178)
17.75"
(451)
21.13"
(537)
19.5"
(495)
1" (25)
2" (51)
.44" (11) Dia.
.78" (20) Dia.
1" (25)
2" (51)
Effective Projected Area (EPA)
The EPA for the InterState™ II is 2.75 sq. ft.
Approx. Wt. = 37 lbs
36
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
InterState™ II Series 775
Roadway Lighting Luminaires — Interstate with Contemporary Style
200-400W HPS, 175-400W MH, 250-400W MV
O R D E R I N G
I N F O R M AT I O N
Example: 7 7 5 4 0 S C A 4 8 0 R 3 S G
Wattage / Source
Series
775 InterState
Roadway
Offset
Voltage
Distribution
120V
208V
220V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual Tap 120/240
wired 120V
DT2 Dual Tap 120/240
wired 240V
DT3 Dual Tap 240/480
wired 240V
DT4 Dual Tap 240/480
wired 480V
R3 Roadway
Type III1
Ballast
17
20
25
31
40
23
175W
S HPS
200W
M MH
250W
V MV
310W
400W
250/400W
wired 250W
24 250/400W
wired 400W
RN
RH
XN
XH
Refer to the ballast matrix on
page 58 for compatibility.
CA
CT
MR
SC
Reactor Normal Power Factor
Reactor High Power Factor
High Reactance (Lag)
Normal Power Factor
High Reactance (Lag)
High Power Factor
CWA
CWI
Mag Reg (3 Coil)
SCWA
120
208
220
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
Optics
SG Sag Glass
Clear Tempered
FG Flat Glass
Clear Tempered
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Mounting
(blank) Tenon Slipfitter (standard)2
YG Yoke Galvanized
YP Yoke Painted2
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle5
Paint3
(blank)
BK
BZ
WH
UP
Lamp
LC
LD
LG
Gray (standard)
Black
Bronze
White
Unpainted
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 and L2 Positions
T3 3 Wire Operation (L1, N, L2
Position)
Standard Listing
(blank) UL Listed (standard)
CS CSA Certified
Fusing4
SF
DF
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Starter7
(blank)
EC
OP
SN
Misc.
PC
TL
BT
SS
PL
LA
5H
NN
SH
Notes:
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Self-Igniting Lamp6
Open Board (standard)
Encapsulated Plug-in
Open Plug-in
No Ignitor (use self-igniting lamp)
1
2
3
4
5
6
7
8
Distribution depends on tilt angle of fixture
Painted to match specified color of fixture
Other colors available, please contact your local
American Electric Lighting representative
Voids UL/CSA Certified Options, not available with
MT, TT, DT voltages
PB, PC, SH not available with NR option
Requires SN starter option
For HPS Products only
Limited availability, please contact your local
American Electric Lighting representative
Photocontrol Included
per Voltage Specified
Tool Less Entry
Ballast Tray
Stainless Steel Fasteners (external)
Distribution Pattern Indicator Label
Lightning Arrestor
50 Hertz Ballast Cycle8
Less NEMA Label
Shorting Cap
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
37
LPS Roadway Series SRP
Roadway Lighting Luminaires
90-180W LPS
P R O D U C T
O V E R V I E W
Features:
Designed for maximum energy savings with efficient light distribution.
Outside housing constructed of non-corrosive ABS plastic with UV inhibiting
coating.
Drop acrylic or polycarbonate prismatic refractor and adjustable socket allows
for maximum control of light distribution.
Photocontrol receptacle is adjustable without tools.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Suitable for -30°C MH & MV / -40°C HPS.
Complies with ANSI: C136.2, C136.10, C136.15
Applications:
Roadways
Highways
Transportation terminals
Security lighting
DIMENSIONS
14"
10"
L"
Mounting end of tenon must have a
6-3/4" straight section (min.)
Accepts
1-1/2" to 2" OD
Mounting
10"
(254)
7"
(179)
SERIES
LENGTH (L)
EPA (Sq. Ft.)
SRP90
55''
1.45
SRP13
55''
1.45
SRP18
65''
1.86
Approx. Wt. = 51 lbs
38
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
LPS Roadway Series SRP
Roadway Lighting Luminaires
90-180W LPS
O R D E R I N G
I N F O R M AT I O N
Example: S R P 1 8 L X H 4 8 0 R 4 D A D F
Series
SRP Low
Pressure
Sodium
Roadway
Wattage / Source
09 90W
13 135W
18 180W
L Low Pressure
Sodium
Refer to the ballast matrix on
page 59 for compatibility.
Voltage
Distribution
Optics
120V
208V
240V
277V
347V
480V
Dual Tap wired 120/240
wired 120V
DT2 Dual Tap wired 120/240
wired 240V
DT5 Dual Tap 208/277
wired 208V
DT6 Dual Tap 208/277
wired 277V
R4 Roadway
Type IV
DA Drop Acrylic
Prismatic Refractor
DP Drop Polycarbonate
Prismatic Refractor
Ballast
RH Reactor High
Power Factor
XH High Reactance (Lag)
High Power Factor
120
208
240
277
347
480
DT1
Options
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
PB Phosphor Bronze Contacts
NR No Photocontrol Receptacle1
Fusing2
SF
DF
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Lamp
LC
Lamp Included, Clear
Misc.
PC
Notes:
1 PB, PC, SH not available with NR option
2 Not available with DT voltages
Photocontrol Included per voltage
specified
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
39
LPS Roadway Series SRX
Roadway Lighting Luminaires
35-90W LPS
P R O D U C T
O V E R V I E W
Features:
Designed for maximum energy savings with efficient light distribution.
Vandal resistant, rugged and corrosion resistant die cast aluminum housing.
Drop acrylic or polycarbonate prismatic refractor allows for maximum control
of light distribution.
Large surface area "breathing seal," gasket seals the optical chamber to
prevent intrusion by insects and environmental contaminants. Heat-resistant
gasket material remains effective over the life of the fixture.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Suitable for -30°C MH & MV / -40°C HPS.
Complies with ANSI: C136.2, C136.10
Applications:
Roadways
Highways
Transportation terminals
DIMENSIONS
Accepts
1.625" to 2.375"
ODA tenon
4.5"
(114)
4"
(102)
27"
(686)
7.5"
(191)
9"
(229)
Mounting end of tenon
must have a 4.5"
straight section (min.)
Effective Projected Area (EPA)
The EPS for the Roadway Luminaire Series SRX is 1.00 sq. ft.
Approx. Wt. = 20 lbs.
40
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
LPS Roadway Series SRX
Roadway Lighting Luminaires
35-90W LPS
O R D E R I N G
I N F O R M AT I O N
Example: S R X 0 9 L R H 4 8 0 R 1 D A L C
Wattage / Source
Series
SRX Low Pressure
Sodium Roadway
03 35W
55 55W
09 90W
L LPS
Refer to the ballast matrix on
page 59 for compatibility.
Voltage
Ballast
RH Reactor High Power
Factor
XH High Reactance (Lag)
High Power Factor
120
208
240
277
347
480
DT1
120V
208V
240V
277V
347V
480V
Dual Tap 120/240
wired 120V
DT2 Dual Tap 120/240
wired 240V
DT5 Dual Tap 208/277
wired 208V
DT6 Dual Tap 208/277
wired 277V
Distribution
R4 Roadway
Type IV
Optics
DA Drop Acrylic
Prismatic Refractor
DP Drop Polycarbonate
Prismatic Refractor
Options
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle (standard)1
NR No Photocontrol Receptacle
PB Phosphor Bronze Contacts
Lamp
LC
Lamp Included, Clear
Misc.
PC
SH
Photocontrol Included per Voltage Specified
Shorting Cap
Notes:
1
PB, PC, SH not available with NR option
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
41
LPS Roadway Series SP2
Roadway Lighting Luminaires
90-180W LPS
P R O D U C T
O V E R V I E W
Features:
Designed for maximum energy savings with efficient light distribution.
Outside housing constructed of non-corrosive ABS plastic with UV inhibiting
coating.
Drop acrylic or polycarbonate prismatic refractor allows for maximum control
of light distribution.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Suitable for -30°C MH & MV / -40°C HPS.
Applications:
Roadways
Highways
Security lighting
Transportation terminals
DIMENSIONS
6-3/4"
(171)
L"
ARMS
Accepts
1-1/2" to 2" OD
Mounting
10"
(254)
7"
(179)
SERIES
LENGTH (L)
EPA (Sq. Ft.)
SP290
397/16''
1.00
SP213
497/16''
1.20
SP218
637/16''
1.45
Approx. Wt. = 31 lbs
42
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
LPS Roadway Series SP2
Roadway Lighting Luminaires
90-180W LPS
O R D E R I N G
I N F O R M AT I O N
Example: S P 2 1 8 L X H 4 8 0 R 4 D P L C
Series
Wattage / Source
09 90W
13 135W
18 180W
SP2 Low Pressure
Sodium
Roadway
L LPS
Refer to the ballast matrix on
page 59 for compatibility.
Voltage
Ballast
RH Reactor High
Power Factor
XH High Reactance
(Lag) High Power
Factor
120
208
240
277
347
480
DT1
120V
208V
240V
277V
347V
480V
Dual Tap wired
120/240 wired 120V
DT2 Dual Tap wired
120/240 wired 240V
DT5 Dual Tap 208/277
wired 208V
DT6 Dual Tap 208/277
wired 277V
Distribution
R4 Roadway
Type IV
Optics
DA Drop Acrylic
Prismatic Refractor
DP Drop Polycarbonate
Prismatic Refractor
Options
Listing
CS
Notes:
CSA Certified
1 PB, PC, SH not available with NR option
Photocontrol Receptacle
(blank) With Photocontrol Receptacle
PB Phosphor Bronze Contacts
NR No Photocontrol Receptacle1
Lamp
LC
Lamp Included, Clear
Misc.
PC
SH
Photocontrol Included per Voltage
Shorting cap
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
43
Underpass Series GST
Roadway Lighting Luminaires
55W LPS
P R O D U C T
O V E R V I E W
Features:
NEW
Utilizes high lumen/watt low pressure sodium lamp for maximum energy
efficiency.
Rugged water tight seal for underpass, subway, and steel mill applications.
Injection molded prismatic polycarbonate refractor to lesson vandalism.
Suitable for high pressure hose down.
Housing constructed of cast corrosion resistant 380 aluminum alloy.
Aluminum reflector is finished in gloss white paint to optimize optical
distribution of light.
Applications:
Office complexes
Shopping centers and malls
Schools and hospitals
Parking garages
Tunnels and underpasses
Parks
DIMENSIONS
12"
(305)
8.75"
(222)
27.5"
(699)
8.5"
(216)
Approx. Wt. = 31 lbs
44
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Underpass Series GST
Roadway Lighting Luminaires
55W LPS
O R D E R I N G
I N F O R M AT I O N
Example: G S T 5 5 L X H D T 1 R 1 D P
Wattage / Source
Series
GST Underpass
Low Pressure
Sodium
55 55 W
L LPS
Voltage
Ballast
XH High Reactance (Lag)
High Power Factor
120
208
240
277
347
480
DT1
DT2
DT3
DT8
120V
208V
240V
277V
347V
480V
Dual Tap 120/240 wired 120V
Dual Tap 120/240 wired 240V
Dual Tap 240/480 wired 240V
Dual Tap 240/480 wired 480V
Distribution
R1 Roadway
Type I
Optics
DP Drop Polycarbonate
Prismatic Refractor
Options
Lamp
LC
Lamp Included, Clear
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
45
Underpass Series 581/681
Roadway Lighting Luminaires
50-250W HPS, 100-250W MV, 175-250W MH
P R O D U C T
O V E R V I E W
Features:
Low profile design for unobtrusive surface mounting.
Die-cast aluminum back housing with choice of die-cast front housing with
borosilicate glass lens, or one-piece polycarbonate front housing and lens.
Designed for easy access to electrical compartment and optical assembly for
installation and maintenance ease.
All exterior hardware is captive.
UL and CSA listed for wet locations.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
E39 mogul socket standard.
Suitable for -30°C MH & MV / -40°C HPS.
Optional (GY) Gray finish shown
Applications:
Office complexes
Shopping centers and malls
Schools and hospitals
Parking garages
Tunnels and underpasses
Parks
DIMENSIONS
14-7/8"
(378)
16-5/8"
(424)
14-7/8"
(378)
7" (179)
8-9/16"
(251)
Approx. Wt. = 30 lbs
46
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Underpass Series 581/681
Roadway Lighting Luminaires
50-250W HPS, 100-250W MV, 175-250W MH
O R D E R I N G
I N F O R M AT I O N
Example: 5 8 1 2 5 S C A M T 1 G Y
Wattage / Source
Series
581 Wall pack w/
die-cast and
glass front
housing
681 Wall pack w/
polycarbonate
front housing1
S HPS
05 50 W
M MH
07 70 W
V MV
10 100 W
15 150 W
17 175 W
20 200 W
25 250 W
Refer to the ballast matrix on
page 59 for compatibility.
Voltage
Ballast
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance (Lag)
Normal Power Factor
XH High Reactance (Lag)
High Power Factor
CA CWA
CT CWI
XX No Ballast
120
208
240
277
347
480
MT1
MT2
MT7
MT8
TT1
TT7
TT3
DT1
DT2
DT3
DT4
120V
208V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 240V
Multi-tap wired 277V
Multi-tap wired 208V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual Tap 120/240 wired 120V
Dual Tap 120/240 wired 240V
Dual Tap 240/480 wired 240V
Dual Tap 240/480 wired 480V
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Mounting
(blank) Wall mount (standard)
Paint2
(blank)
BK
WH
GY
UP
Bronze (standard)
Black
White
Gray
Unpainted
Listing
(blank)
CS
UL Listing (standard)
CSA Certified
Fusing3
SF
DF
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Photocontrol
(blank) Button control is standard
(multi-volt options not available)
NC No Photocontrol
Lamp
LC
LD
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Misc.
SE
SS
5H
NL
Side Entry
Stainless Steel Fasteners (external)
50 Hertz Ballast Cycle4
NEMA Label
Notes:
1
2
3
4
See pages 259-264 for a complete listing
of Frequently Ordered Products
Max Wattage 175W, only available in bronze
Other colors available, please contact your local
American Electric Lighting representative
Voids UL/CSA Certified Options, not available
with MT, TT, DT voltages
Limited availability, please contact your local
American Electric Lighting representative
Product Guide
47
Heavy-Duty Wallpack Series 882
Building-Mounted Luminaires
250 & 400W HPS/MH
P R O D U C T
O V E R V I E W
Features:
Designed for easy access to electrical compartment and optical assembly for
installation and maintenance ease.
Heavy duty, two piece, die cast aluminum housing with hinged, captive bezel
and corrosion resistant hardware.
Completely sealed with high temperature silicone gasket.
High impact and heat resistant borosilicate glass refractor.
One piece, stippled, asymmetric anodized aluminum reflector designed to
produce a wide pattern of efficient illumination.
UL and CSA certified for wet locations.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Suitable for -30°C MH & MV / -40°C HPS.
Applications:
Parking areas
Perimeter lighting
Entrances and walkways
Waterfront areas
Loading platforms
Recreational areas
DIMENSIONS
17"
(432)
12-3/4"
(324)
9"
(229)
Approx. Wt. = 36 lbs
48
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Heavy-Duty Wallpack Series 882
Building-Mounted Luminaires
250 & 400W HPS/MH
O R D E R I N G
I N F O R M AT I O N
Example: 8 8 2 2 5 S C A M T 1
Wattage / Source
Series
882 Wall Pack
25 250W
40 400W
S HPS
M MH
Refer to the ballast matrix on
page 60 for compatibility.
Voltage
Ballast
CA CWA
CT CWI
MR Mag Reg
480
MT1
MT2
MT7
MT8
TT1
TT7
TT3
480V
Multi-tap wired 120V
Multi-tap wired 240V
Multi-tap wired 277V
Multi tap wired 208V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Options
Listing
(blank)
CS
UL Listed (standard)
CSA Certified
Lamp
LC
LD
Lamp Included, Clear
Lamp Included, Deluxe/Coated
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
49
Signlite Series 875
Sign Light
175-400W MV, 175-400W MH, 100-400W HPS
P R O D U C T
O V E R V I E W
Features:
Die cast low copper aluminum housing offers light weight and corrosion
resistance with excellent durability.
Hinged door is easily removable for quick maintenance, single fastener makes
relamping easy (optional tool-less entry available).
Anodized aluminum reflector provides uniform lighting distribution with sag or
flat clear tempered glass lens.
UL listed for wet locations.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Suitable for -30°C MH & MV / -40°C HPS.
Complies with ANSI: C136.2, C136.10, C136.15
Applications:
Interstate highways
Outdoor advertising signs
Traffic flow signs
Building facades
Security lighting
Corporate and building lighting
Other vertical surfaces, watts
DIMENSIONS
17.75"
(451)
7"
(178)
23"
(584)
19.5"
(495)
2"
(51)
7"
(178)
17.75"
(451)
21.13"
(537)
19.5"
(495)
1" (25)
2" (51)
.44" (11) Dia.
.78" (20) Dia.
1" (25)
2" (51)
Effective Projected Area (EPA)
The EPA for the Signlite Luminaire, Series 875 is 2.75 sq. ft.
Approx. Wt. = 37 lbs
50
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Signlite Series 875
Sign Light
175-400W MV, 175-400W MH, 100-400W HPS
O R D E R I N G
I N F O R M AT I O N
Example: 8 7 5 4 0 M C A 4 8 0 6 6 S G
Wattage / Source
Series
875 Sign Light
Voltage
Ballast
S HPS
100W
M MH
150W
V MV
175W
200W
250W
310W
400W
250/400W
wired 250W
24 250/400W
wired 400W
Refer to the ballast matrix on
page 60 for compatibility.
10
15
17
20
25
31
40
23
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance / Lag
Normal Power Factor
XH High Reactance / Lag
High Power Factor
CA CWA Auto Reg
CT CWI
MR Mag Reg (3 Coil)
SC SCWA
120
208
220
240
277
347
480
MT1
MT2
MT7
MT8
TT1
TT7
TT3
DT1
DT2
DT3
DT4
120V
208V
220V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 240V
Multi-tap wired 277V
Multi-tap wired 208V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual Tap 120/240 wired 120V
Dual Tap 120/240 wired 240V
Dual Tap 240/480 wired 240V
Dual Tap 240/480 wired 480V
Distribution1
56 5H X 6V NEMA
distribution
66 6H X 6V NEMA
distribution
Optics
SG Sag Glass
Clear Tempered
FG Flat Glass
Clear Tempered
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Mounting
(blank) Tenon Mount (standard)2
YG Yoke Galvanized
YP Yoke Painted2
Photocontrol Receptacle
(blank) Photocontrol Receptacle (standard)
NR No Photocontrol Receptacle5
PB Phosphor Bronze Contacts
Paint3
(blank)
BK
BZ
WH
UP
Lamp
LC
LD
SL
Gray (standard)
Black
Bronze
White
Unpainted
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 and L2 Position
T3 3 Wire Operation (L1, N, L2
Position)
Listing
(blank)
CS
UL Listed (standard)
CSA Certified
Fusing4
SF
DF
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Notes:
3
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Self-Igniting Lamp6
Starter7
EC Encapsulated Plug-in
OP Open Plug-in
SN No Ignitor (using self-igniting lamp)
Misc.
TL
BT
SS
CF
LA
PC
5H
NL
SH
1
2
Tool-less Entry
Ballast Tray
Stainless Steel Fasteners (external)
Charcoal Filter
Lightning Arrestor
(Void UL/CSA Listed Options)
Photocontrol Included per
Voltage Specified
50 Hertz Ballast Cycle8
NEMA Label
Shorting Cap
See pages 259-264 for a complete listing
of Frequently Ordered Products
4
5
6
7
8
Distribution depends on tilt angle of fixture
Painted to match specified color of
fixture
Other colors available, please contact
your local American Electric Lighting
representative
Voids UL/CSA Certified Options; not
available with MT, TT, DT voltages
PB, PC, and SH not available with NR
option
Requires SN option
Available in HPS only
Limited availability, please contact
your local American Electric Lighting
representative
Product Guide
51
Accessories
AVA I L A B I L I T Y
Roadway
115-GS
115-HS1
413-GS
413-HS1
125-GS
125-HS1
581-VS2
581-WG2
882-VS2
882-WG2
882-PEC
115
◆
◆
-
315
◆
-
413
◆
◆
-
125 325
◆
◆ ◆
-
327 20
-
30
-
185
-
285 775 SRP SRX
-
SP2 581
◆
◆
-
Shields/Guards
HS
GS
VS
WG
52
Houseside shield
Glare shield
Vandal proof shield
Wire guard
Product Guide
Notes:
1 Drop lens only
2 Vandal shield and wire guard can not be used simultaneously
For photometric information, visit our website,
www.americanelectriclighting.com
882
◆
◆
◆
Accessories
S H I E L D S
Description
Catalog Number
115-GS
GLARE SHIELD
125-GS
FOR COBRAHEAD SERIES
115-HS
HOUSE SIDE SHIELD
413-HS
125-HS
POLYCARBONATE SHIELD
FOR SIDELITE 581
BALLISTIC SHIELDS
581-VS
115 or 315 PGS FL 25W
115 or 315 PGS FL 25W SPS
115 or 315 PGS DL 25W
115 or 315 PGS DL 250 SPS
125 or 325 PGS FL 40W
125 or 325 PGS FL 40W SPS
125 or 325 PGS DL 40W
125 or 325 PGS DL 40W SPS
6.25"
(159)
8.67"
(220)
WIRE GUARDS
6.50"
(194)
16.63"
(422)
17.00"
(432)
581 WG
882-WG
6.50"
(165)
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
53
Roadway Lighting
B A L L A S T
M AT R I C E S
DuraStar™ Series 20
Watts
03S
05S
07S
10S
10V
15S
17V
17M
120
RN
RH,RN,XN
XH,RH,CA,CT,RN,XN,MR
XH,XN,CA,CT,MR,RH,RN
XH,XN
XH,RH,CA,CT,MR,RN,XN
RH,XN
CA,CT
208
XN
XH,CA,CT,MR,XN
XH,CA,CT,MR,XN
CA,CT
XH,CA,CT,MR,XN
CA,CT
CA,CT
220
RH
RN
-
240
XN
XH,CA,CT,MR,XN
XH,CA,CT,MR,XN
RH,RN
XH,RH,CA,CT,MR,RN,XN
RH,RN
CA,CT
277
XN
XH,CA,CT,MR,XN
CA,CT,XH,MR,XN
CA,CT
XH,CA,CT,MR,XN
CA,CT,RH,RN,
CA,CT
480
XH,XN
CA,CT,MR
CA,CT,MR
CA,CT
DT1
XN
XN,CA
CA,CT,XH,MR,XN
CA,CT
XH,XN,CA,CT,MR
CA,CT
CA,CT
DT2
CA,CT,MR
CA,CT,MR,XH
CA,CT
XH,XN,CA,CT,MR
CA,CT
CA,CT
DT3
CA,CT
CA,CT
-
DT4
CA,CT,MR
CA,CT
CA,CT
-
DuraStar™ Series 20 continued
Watts
03S
05S
07S
10S
10V
15S
17V
17M
MT1
XN
XN,XH
CA,CT,XN,XH
CA,CT
XN,XH,CA,CT
XN,XH
XN,XH,CA,CT
MT2
XN
XN,XH
CA,CT, XN,XH
CA,CT
XN,XH,CA,CT
XN,XH
XN,XH,CA,CT
MT7
XN
XN,XH
CA,CT,XN,XH
CA,CT
XN,XH,CA,CT
XN,XH
XN,XH,CA,CT
MT8
XN
XN,XH
CA,CT,XN,XH
CA,CT
XN,XH
XN,XH
XN,XH,CA,CT
TT1
XN,XH
XN,XH
XN,XH
XN,XH
-
TT7
XN,XH
XN,XH
XN,XH
XN,XH
-
TT3
XN,XH
XN,XH
XN,XH
XN,XH
-
DuraStar™ Series 30
Watts
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
23/24M
120
XH,XN
CA,CT
XH,CA,CT,MR,,XN
XH,XN,CA,CT,MR
XH,XN,CA,CT
CA,CT
MR
XH,XN,CA,CT,MR
XH,XN
CA,CT
CA,CT,
CA,CT,
208
CA,CT
CA,CT
CA,CT,MR
CA,CT,MR
CA,CT
CA,CT
MR
CA,CT,MR
CA,CT
CA,CT
CA,CT
CA,CT
220
RH,RN
RH
RH,CA,CT
RN,RH
RH,CA,CT
RH,,RN
-
240
RH,RN
,CA,CT
XH,CA,CT,MR,XN
RH.RN,CA,CT,XH,MR,XN
RH.RN,CA,CT
CA,CT
RH,MR,RN
RH,RN,CA,CT,
RH,RN,CA,CT,
CA,CT
CA,CT
CA,CT
277
CA,CT,RH,RN
CA,CT
CA,CT,MR
CA,CT,MR
CA,CT
CA,CT
MR
MR
RH,CA,CT,RN
CA,CT
CA,CT
CA,CT
347
CA,CT
CA,CT
CA,CT
CA,CT
CA,CT
-
480
CA,CT
CA,CT,MR
CA,CT,MR
CA,CT
MR
CA,CT,MR
CA,CT
CA,CT
CA,CT
DT1
CA,CT
CA,CT
XH,XN
CA,CT,XH,MR,XN
CA,CT
CA,CT
MR
MR
CA,CT
CA,CT
CA,CT
CA,CT
DT2
CA.CT
CA.CT
XH,XN,CA,CT,MR
CA,CT
CA,CT
MR
MR
CA,CT
CA,CT
CA,CT
CA,CT
DuraStar™ Series 30 continued
Watts
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
23/24M
54
DT3
CA,CT,MR
CA,CT
MR
CA,CT
-
Product Guide
DT4
CA,CT,MR
CA,CT
MR
CA,CT
-
MT1
XN,XH,CA,CT
XN,XH,CA,CT
CA,CT,MR,XH,XN
CA,CT,MR,XH,XN
XN,XH,CA,CT
XN,XH,CA,CT
MR
CA,CT,MR,XH,XN
XN,XH,CA,CT
XN,XH,CA,CT
XN,XH,CA,CT
XN,XH,CA,CT
MT2
XN,XH,CA,CT
XN,XH,CA,CT
CA,CT,MR,XH,XN
CA,CT,MR,XH,XN
XN,XH,CA,CT
XN,XH,CA,CT
MR
CA,CT,MR,XH,XN
XN,XH,CA,CT
XN,XH,CA,CT
XN,XH,CA,CT
XN,XH,CA,CT
MT7
XN,XH,CA,CT
XN,XH,CA,CT
CA,CT,MR,XH,XN
CA,CT,MR,XH,XN
XN,XH,CA,CT
XN,XH,CA,CT
MR
CA,CT,MR,XH,XN
XN,XH,CA,CT
XN,XH,CA,CT
XN,XH
XN,XH,CA,CT
For photometric information, visit our website,
www.americanelectriclighting.com
MT8
XN,XH,CA,CT
XN,XH,CA,CT
CA,CT,MR,XH,XN
CA,CT,MR,XH,XN
XN,XH,CA,CT
XN,XH,CA,CT
MR
CA,CT,MR,XH,XN
XN,XH,CA,CT
XN,XH,CA,CT
XN,XH,CA,CT
XN,XH,CA,CT
TT1
XN,XH
CA
CA
CA
CA
CA
CA
-
TT7
XN,XH
CA
CA
CA
CA
CA
CA
-
TT3
XN,XH
CA
CA
CA
CA
CA
CA
-
Roadway Lighting
B A L L A S T
M AT R I C E S
Roadway 115
Watts
03S
05S
07S
10S
10V
15S
13S
14S
17V
17M
20S
25S
25V
25M
40S
120
RN,RH
RH,RN
RH,CA,CT,RN,MR
CA,CT,MR,RH,RN
XH,XN,CA,CT
RN,RH,CA,CT,MR
RN,RH
RN,RH
XN,XH,CA,CT
CA
CA,CT,XN,XH
CA,CT,XN,XH
XN,XH,CA,CT
CA,CT
-
208
XH,XN
XH,CA,CT,XN
XH,CA,CT,XN
CA
CA,CT,XN,XH
CA
CA
CA,CT
CA,CT
CA
CA
RN,RH
220
CA
RN,RH
230
RN,RH
RN,RH
RN,RH
-
240
XH,XN
XH,CA,CT,MR,XN
XH,CA,CT,MR,XN
CA,CT
CA,CT,XN,XH,MR
CA,CT,RN,RH
CA
RN,RH,CA,CT,XN,XH
RN,RH,CA,CT
RN,RH,CA,CT
CA,CT
-
277
XH,XN
XH,CA,XN
CA,XH,XN
XN,XH,CA
XN,XH,CA
CA,RN
CA
CA,CT
CA,CT
CA
CA
-
480
DT1
XH,XN
MR
XH,XN,CA,CT,MR
CA
CA,CT,XH,MR,XN
CT
CT
CA,MR XN,XH,CA,CT,MR
CA,CT
CT, CA
CA
CA
CA,CT
CA,CT,XN,XH
CA,CT
XN,XH,CA,CT
CA,CT
CA,CT
CA,CT
CA,CT
-
DT2
XH,XN
XH,XN,CA,CT,MR
CA,CT,MR,XH,XN
CT,CA
XN,XH,CA,CT, MR
CT,CA
CA
CA,CT,XN,XH
XN,XH,CA,CT
CA,CT
CA,CT
-
DT3
MR
CT
MR
CT
CT
CT
-
DT4
MR
CT
MR
CT
CT
CT
-
Roadway 115 continued
Watts
03S
05S
07S
10S
10V
15S
13S
14S
17V
17M
20S
25S
25V
25M
40S
MT1
XH,XN
XH,XN,CA
CA,XN,XH
CA
XN,XH,CA
CA
CA
CA,CT
CA,CT
CA
CA
-
MT2
XN,XH
XH,XN,CA,
CA,XN,XH
CA
XN,XH,CA
CA
CA
CA,CT
CA,CT
CA
CA
-
MT7
XN,XH
XH,XN,CA,
CA,XN,XH
CA
XN,XH,CA
CA
CA
CA,CT
CA,CT
CA
CA
-
MT8
XN,XH
XH,XN,CA
CA,XN,XH
CA
XN,XH,CA
CA
CA
CA,CT
CA,CT
CA
CA
-
TT1
XN,XH
XN,XH
XN,XH
XN,XH
CA
CA,CT
CA
-
TT3
347
XN,XH XN,XH,CA,CT
XN,XH
XN,XH
XN,XH
XN,XH
XN,XH XN,XH,CA
CA
CA
CA,CT
CA,CT
CA
CA
CA
-
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
55
Roadway Lighting
B A L L A S T
M AT R I C E S
Roadway 315
Watts
03S
05S
07S
10S
10V
15S
13S
14S
17V
17M
20S
25S
25V
25M
40S
120
RN,RH
RH,RN
RH,CA,CT,RN,MR
CA,CT,MR,RH,RN
XH,XN,CA,CT
RH,CA,CT,MR,RN
RN,RH
RN,RH
XN,XH,CA,CT
CA
XH,CA,CT,XN
XH,CA,CT,XN
XN,XH,CA,CT
CA,CT
XH,XN,CA
208
XH,XN
XH,CA,CT,XN
XH,CA,CT,XN
CA
XH,CA,CT,XN
CA
CA
CA,CT
CA,CT
CA
CA
CA
220
CA
RH,CA
230
RN,RH
RN,RH
RN,RH
-
240
XH,XN
XH,CA,CT,MR,XN
XH,CA,CT,MR,XN
CA,CT
XH,CA,CT,MR,XN
RH,RN,CA,CT
CA
XH,RH,CA,CT,RN,XN
RH,CA,CT,RN
RH,RN,CA,CT
CA,CT
RH,RN,CA
277
XH,XN
XH,CA,XN
CA,XH,XN
CA,XN,XH
XH,CA,XN
CA,RN
CA
CA,CT
CA,CT
CA
CA
-
480
MR
CA
CT
CA
CA,CT
CA
CA,CT
CA,CT
CA,CT
CA,CT
CA
DT1
XH,XN
XH,XN,CA,CT,MR
CA,CT,XH,MR,XN
CT
XH,XN,CA,CT,MR
CA,CT
CA
XH,XN,CA,CT
XH,XN,CA,CT
CA,CT
CA,CT
-
DT2
XH,XN
XH,XN,CA,CT,MR
CA,CT,MR,XH,XN
CA,CT
XH,XN,CA,CT,MR
CA,CT
CA
XH,,XN,CA,CT
XN,XH,CA,CT
CA,CT
CA,CT
-
DT3
MR
CT
MR
CT
CT
CT
-
Roadway 315 continued
Watts
03S
05S
07S
10S
10V
15S
13S
14S
17V
17M
20S
25S
25V
25M
40S
DT4
MR
CT
MR
CT
CT
CT
-
MT1
XH,XN
XH,XN,CA
CA,XN,XH
CA
XN,XH,CA
CA
CA
CA,CT
CA,CT
CA
CA
CA,XN,XH
MT2
XN,XH
XH,XN,CA
CA, XN,XH
CA
XN,XH,CA
CA
CA
CA,CT
CA,CT
CA
CA
CA,XN,XH
MT7
XN,XH
XH,XN,CA
CA,XN,XH
CA
XN,XH,CA
CA
CA
CA,CT
CA,CT
CA
CA
CA,XN,XH
MT8
XN,XH
XH,XN,CA
CA,XN,XH
CA
XN,XH,CA
CA
CA
CA,CT
CA,CT
CA
CA
CA,XN,XH
TT1
XN,XH
XN,XH
XN,XH
XN,XH
CA
CA,CT
CA
-
TT3
XN,XH
XN,XH
XN,XH
XN,XH
CA
CA,CT
CA
-
347
XN,XH,CA,CT
XN,XH
XN,XH
XN,XH,CA
CA
CA,CT
CA
CA
-
Roadway 125
Watts
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
23/24M
120
XN,XH,CA,CT
CA
CA, CT, XN, XH MR
XH,XN,CA,CT,MR
CT,CA,XN,XH
CA,CT,SC
CA,MR
CA,CT,XN,XH,MR
CA,CT,XN,XH
CA,CT,SC
CA,CT,
CA
208
CA
CA
CA, CT
CA,CT
CA
CA,CT,SC
CA
CA,CT
CA,CT
CA,CT,SC
CA,CT,
CA
220
CA
RN,RH
CA
CA
RN,RH
CA
CA
-
230
RN,RH
RN,RH
RN,RH
-
MT2
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
MT7
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
MT8
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
240
277
CA,CT,RN,RH
CA,RN
CA
CA
CA,CT,RN,RH,MR CA,CT,MR
RN,RH,CA,CT,MR CA,CT
RH.RN,CA,CT
CA
CA,CT,SC
CA,SC
CA,MR
CA
RH,RN,CA,CT,MR CA,CT
CA,CT,XN,XH
CA,CT
CA,CT,SC
CA,SC
CA,CT
CA,CT
CA
CA
480
DT1
DT2
CA,CT
CT, CA
CT,CA
CA
CA
CA
CA,CT,MR XN,XH,CA,CT,MRXN,XH,CA,CT,MR
CA,MR
XN,XH,MR
XN,XH,MR
CA,CT
CA,CT
CA,CT
CA,CT
CA,CT,SC
CA,CT,SC
CA,MR
CA,MR
CA,MR
CA,MR CA,CT,MR,XN,XHCA,CT,MR,XN,XH
CT,CA
CA,CT,XN,XH CA,CT,XN,XH
CA,CT,
CA,CT
CA,CT
CA
CA,CT
CA,CT
CA
CA
CA
Roadway 125 continued
Watts
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
23/24M
56
MT1
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
Product Guide
TT1
CA
CA
CA
CA
CA
CA
-
TT7
CA
CA
CA
CA
CA
CA
-
TT3
CA
CA
CA
CA
CA
CA
-
For photometric information, visit our website,
www.americanelectriclighting.com
347
CA
CA
CA
CA
CA
CA
CA
-
DT3
CT
MR
MR
CT
CT
MR
MR
CT
CT
-
DT4
CT
MR
MR
CT
CT
MR
MR
CT
CT
-
Roadway Lighting
B A L L A S T
M AT R I C E S
Roadway 325
Watts
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
23/24M
120
XN,XH,CA,CT
CA
CA, CT, XN, XH MR
XH,XN,CA,CT,MR
CT,CA,XN,XH
CA,CT,SC
CA,MR
CA,CT,XN,XH,MR
CA,CT,XN,XH
CA,CT,SC
CA,CT,
CA
208
CA
CA
CA, CT
CA,CT
CA
CA,CT,SC
CA
CA,CT
CA,CT
CA,CT,SC
CA,CT,
CA
220
CA
RN,RH
CA
CA
RN,RH
CA
CA
-
230
RN,RH
RN,RH
RN,RH
-
240
CA,CT,RN,RH
CA
CA,CT,RN,RH,MR
RN,RH,CA,CT,MR
RH.RN,CA,CT
CA,CT,SC
CA,MR
RH,RN,CA,CT,MR
CA,CT,XN,XH
CA,CT,SC
CA,CT
CA
277
CA,RN
CA
CA,CT,MR
CA,CT
CA
CA,SC
CA
CA,CT
CA,CT
CA,SC
CA,CT
CA
480
CA,CT
CA
CA,CT,MR
CA,MR
CA,CT
CA,CT
CA,MR
CA,MR
CT,CA
CA,CT,
CA
CA
DT1
CT, CA
CA
XN,XH,CA,CT,MR
XN,XH,MR
CA,CT
CA,CT,SC
CA,MR
CA,CT,MR,XN,XH
CA,CT,XN,XH
CA,CT
CA,CT
CA
DT2
CT,CA
CA
XN,XH,CA,CT,MR
XN,XH,MR
CA,CT
CA,CT,SC
CA,MR
CA,CT,MR,XN,XH
CA,CT,XN,XH
CA,CT
CA,CT
CA
DT3
CT
MR
MR
CT
CT
MR
MR
CT
CT
-
DT4
CT
MR
MR
CT
CT
MR
MR
CT
CT
-
Roadway 325 continued
Watts
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
23/24M
MT1
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
MT2
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
MT7
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
MT8
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
TT1
CA
CA
CA
CA
CA
CA
-
TT7
CA
CA
CA
CA
CA
CA
-
TT3
CA
CA
CA
CA
CA
CA
-
347
CA
CA
CA
CA
CA
CA
CA
-
Roadway 327
Watts
31S
40S
40V
40M
75S
75M
XS
XV
XM
120
CA
CA,CT,XN,XH,MR
CA,CT,XN,XH
CA,CT,SC
CA
SC
CA,CT
CA
CA,SC
208
CA
CA,CT
CA,CT
CA,CT,SC
CA
SC
CA,CT
CA
CS,SC
220
RN5,RH5
CA5
CA5
230
CA 5H
-
240
CA
RH,RN,CA,CT,MR
CA,CT,XN,XH
CA,CT,SC
CA
SC
CA,CT
CA
CA,SC
277
CA
CA,CT
CA,CT
CA,SC
XX
SC
CA,CT
CA
CA,SC
480
CA
CA,MR
CT,CA
CA,CT,
SC
CA,CT
CA
CA,SC
DT1
CA
CA,CT,,XN,XH,MR
CA,CT,XN,XH
CA,CT
CA
SC
CA,CT
CA
CA,SC
DT2
CA
CA,CT,,XN,XH,MR
CA,CT,XN,XH
CA,CT
CA
SC
CA,CT
CA
CA,SC
DT3
MR
CT
CT
-
DT4
MR
CT
CT
-
MT1
CA
CA,CT
CA
CA,SC
SC
CA
CA
CA,SC
Roadway 327 continued
Watts
31S
40S
40V
40M
75S
75M
XS
XV
XM
MT2
CA
CA,CT
CA
CA,SC
SC
CA
CA
CA,SC
MT7
CA
CA,CT
CA
CA,SC
SC
CA
CA
CA,SC
MT8
CA
CA,CT
CA
CA,SC
SC
CA
CA
CA,SC
TT1
CA
CA
CA
SC
CA
CA,SC
TT7
CA
CA
CA
SC
CA
CA,SC
TT3
CA
CA
CA
SC
CA
CA,SC
347
CA
CA
CA
SC
CA
CA,SC
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
57
Roadway Lighting
B A L L A S T
M AT R I C E S
Roadway 413
Watts
03S
05S
07S
10S
15S
120
RH,RN
RH,RN
RH,RN
RH,RN
RH,RN
240
RH,RN
RH
RH,RN
Multi-Mount™ 285
Watts
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
120
XH,CA,CT,MR,XN
XN,CA,CT,MR,XH
XH,XN, CA
CA
MR
XN,CA,CT,MR,XH
XH,XN, CA
CA
CA
208
CA,CT
CA,CT
CA
CA
CA,CT
CA
CA
CA
240
RN,RH,CA,CT, MR
RH,RN,CA,CT, MR
RH.RN
CA
MR
RH.RN,CA,CT, MR
CA
CA
CA
277
CA,CT
CA,CT
CA
CA
CA,CT
CA
CA
CA
480
DT1
DT2
CA,CT,MRXH,XN,CA,CT,MR XH,XN,CA,CT,MR
CA,CT,MRXH,XN,CA,CT,MR XH,XN,CA,CT,MR
CA
CA
CA
CA
CA
MR
MR
MR
CA,CT,MR CA,CT,MR
CA,CT,MR
CA
CA
CA
CA
CA
CA
CA
CA
DT3
MR
MR
CA
MR
MR
CA
-
230
RN,RH
RN,RH
RN,RH
-
480
CA,CT
CA
CA,CT,MR
CA,
CA,CT
CA,CT
CA,
CA,
CT,CA
CA,CT,
CA
CA
DT4
MR
MR
CA
MR
MR
CA
-
MT1
CA,CT
CA,CT
CA
CA
CA,CT
CA
CA
CA
MT2
CA,CT
CA,CT
CA
CA
CA,CT
CA
CA
CA
Multi-Mount™ 285 continued
Watts
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
MT7
CA,CT
CA,CT
CA
CA
CA,CT
CA
CA
CA
MT8
CA,CT
CA,CT
CA
CA
CA,CT
CA
CA
CA
TT1
CA
CA
CA
CA
-
TT7
CA
CA
CA
CA
-
TT3
CA
CA
CA
CA
-
347
CA
CA
CA
CA
-
Interstate™ II 775
Watts
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
23/24M
120
XN,XH,CA,CT
CA
CA, CT, XN, XH ,MR
XH,XN,CA,CT,
CT,CA,XN,XH
CA,CT,SC
CA,MR
CA,CT,XN,XH,
CA,CT,XN,XH
CA,CT,SC
CA,CT,
CA
208
CA
CA
CA, CT
CA,CT
CA
CA,CT,SC
CA
CA,CT
CA,CT
CA,CT,SC
CA,CT,
CA
220
RN,CA
CA,RN,RH
CA
CA
RN,RH
CA
-
240
CA,CT,RN,RH
CA
CA,CT,RN,RH,MR
RN,RH,CA,CT,
RH.RN,CA,CT
CA,CT,SC
CA,MR
RH,RN,CA,CT,
CA,CT,XN,XH
CA,CT,SC
CA,CT
CA
277
CA,RN
CA
CA,CT,
CA,CT
CA
CA,SC
CA
CA,CT
CA,CT
CA,SC
CA,CT
CA
Interstate™ II 775 continued
Watts
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
23/24M
58
DT3
CT
MR
CT
CT
CT
CT
-
Product Guide
DT4
CT
MR
CT
CT
CT
CT
-
MT1
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
MT2
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
MT7
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
MT8
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
TT1
CA
CA
CA
CA
CA
CA
-
TT7
CA
CA
CA
CA
CA
CA
-
TT3
CA
CA
CA
CA
CA
CA
-
347
CA
CA
CA
CA
CA
CA
CA
-
For photometric information, visit our website,
www.americanelectriclighting.com
DT1
CT, CA
CA
XN,XH,CA,CT, MR
XN,XH,MR
CA,CT
CA,CT,SC
CA,
CA,CT,,XN,XH
CA,CT,XN,XH
CA,CT
CA,CT
CA
DT2
CT,CA
CA
XN,XH,CA,CT,MR
XN,XH,
CA,CT
CA,CT,SC
CA
CA,CT,,XN,XH
CA,CT,XN,XH
CA,CT
CA,CT
CA
Roadway Lighting
B A L L A S T
M AT R I C E S
LPS Roadway SRP
Watts
13L
18L
09L
120
XH
XH
XH
208
XH
XH
XH
240
XH
XH
XH
277
XH
XH
XH
347
XH
XH
XH
480
XH
XH
RH
208
XH
XH
XH
240
XH
XH
XH
277
XH
XH
XH
347
XH
XH
XH
480
RH
RH
RH
208
XH
XH
XH
240
XH
XH
XH
277
XH
XH
XH
347
XH
XH
XH
480
RH,XH
XH
XH
DT1
XH
XH
XH
DT2
XH
XH
XH
DT5
XH
XH
XH
DT6
XH
XH
XH
LPS Roadway SRX
Watts
03L
55L
09L
120
XH
XH
XH
DT1
XH
XH
XH
DT2
XH
XH
XH
DT5
XH
XH
XH
DT6
XH
XH
XH
LPS Roadway SP2
Watts
13L
18L
09L
120
XH
XH
XH
DT1
XH
XH
XH
DT2
XH
XH
XH
DT5
XH
XH
XH
DT6
XH
XH
XH
UnderPass Series 581/681
Watts
05S
07S
10S
10V
15S
17V
17M
20S
25S
25V
25M
120
RN
RN, RH, CA, CT, MR
RN, RH, CA, CT
XN, XH, CT
RN, RH, CA, MR
XN, XH, CA, CT
CA
XN, XH
XN, XH
CA
CA
208
XN, XH, CA, CT
XN, XH, CA, CT
XN, XH, CA
CA
CA
CA
CA
240
XN, XH, CA, CT, MR
XN, XH, CA, CT
CT
XN, XH, CA, MR
RN, RH, CA, CT
CA
XN, XH
XN, XH
CA
CA
277
XN, XH, CA
XN, XH, CA, CT
XN, XH, CA
RN, RH, CA
CA
CA
CA
480
CA, MR
CA
CA, MR
CA
CA
-
DT1
XN, XH, CA, CT, MR
CA, CT
CT
CA, MR
CA , CT
CA
XN, XH
XN, XH
CA
CA
DT2
XN, XH, CA, CT, MR
CA, CT
CT
CA, MR
CA, CT
CA
XN, XH
XN, XH
CA
CA
DT3
MR
MR
-
UnderPass Series 581/681 continued
Watts
05S
07S
10S
10V
15S
17V
17M
20S
25S
25V
25M
DT4
MR
MR
-
MT1
CA
CA, CT
CA
CA
CA
CA
CA
MT2
CA
CA, CT
CA
CA
CA
CA
CA
MT7
CA
CA, CT
CA
CA
CA
CA
CA
MT8
CA
CA, CT
CA
CA
CA
CA
CA
TT1
XN, XH
XN, XH
XN, XH
CA
CA
-
TT3
XN, XH
XN, XH
XN, XH
CA
CA
-
See pages 259-264 for a complete listing
of Frequently Ordered Products
TT7
XN, XH
XN, XH
XN, XH
CA
CA
-
347
XN, XH, CT
XN, XH, CT
XN, XH
CA
CA
-
Product Guide
59
Roadway Lighting
B A L L A S T
M AT R I C E S
Heavy-Duty Wallpack 882
Watts
25S
25M
40S
40M
MT1
CA,CT
CA,CT
CA,CT
CA,CT
MT2
CA,CT
CA,CT
CA,CT
CA,CT
MT7
CA,CT
CA,CT
CA,CT
CA,CT
MT8
CA,CT
CA,CT
CA,CT
CA,CT
TT1
CA,CT
CA,CT
CA,CT
CA,CT
TT7
CA,CT
CA,CT
CA,CT
CA,CT
TT3
CA,CT
CA,CT
CA,CT
CA,CT
480
CA,CT
-
Signlite 875
Watts
10S
10V
15S
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
23/24M
120
CA,CT,MR,RH,RN
XH,XN,CA,CT
RN,RH,CA,CT,MR
XN,XH,CA,CT
CA
CA, CT, XN, XH ,MR
XH,XN,CA,CT,
CT,CA,XN,XH
CA,CT,SC
CA,MR
CA,CT,XN,XH,
CA,CT,XN,XH
CA,CT,SC
CA,CT,
CA
208
XH,CA,CT,XN
CA
CA,CT,XN,XH
CA
CA
CA, CT
CA,CT
CA
CA,CT,SC
CA
CA,CT
CA,CT
CA,CT,SC
CA,CT,
CA
220
RN,CA
CA,RN,RH
CA
CA
RN,RH
CA
-
230
RN,RH
RN,RH
RN,RH
RN,RH
-
240
XH,CA,CT,MR,XN
CA,CT
CA,CT,XN,XH,MR
CA,CT,RN,RH
CA
CA,CT,RN,RH,MR
RN,RH,CA,CT,
RH.RN,CA,CT
CA,CT,SC
CA,MR
RH,RN,CA,CT,
CA,CT,XN,XH
CA,CT,SC
CA,CT
CA
277
CA,XH,XN,CT
XN,XH,CA
XN,XH,CA
CA,RN
CA
CA,CT,
CA,CT
CA
CA,SC
CA
CA,CT
CA,CT
CA,SC
CA,CT
CA
480
CA
CT
CA,MR
CA,CT
CA
CA,CT,MR
CA,
CA,CT
CA,CT
CA
CA,
CT,CA
CA,CT,
CA
CA
DT1
CA,CT,XH,MR,XN
CT
XN,XH,CA,CT,MR
CT, CA
CA
XN,XH,CA,CT, MR
XN,XH,MR
CA,CT
CA,CT,SC
CA
CA,CT,,XN,XH
CA,CT,XN,XH
CA,CT
CA,CT
CA
DT2
CA,CT,MR,XH,XN
CT,CA
XN,XH,CA,CT, MR
CT,CA
CA
XN,XH,CA,CT,MR
XN,XH
CA,CT
CA,CT,SC
CA
CA,CT,,XN,XH
CA,CT,XN,XH
CA,CT
CA,CT
CA
Signlite 875 continued
Watts
10S
10V
15S
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
23/24M
60
DT3
CT
MR
CT
MR
CT
CT
CT
CT
-
Product Guide
DT4
CT
MR
CT
MR
CT
CT
CT
CT
-
MT1
CA,XN,XH,CT
CA
XN,XH,CA,CT
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
MT2
CA,XN,XH,CT
CA
XN,XH,CA,CT
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
MT7
CA,XN,XH,CT
CA
XN,XH,CA,CT
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
MT8
CA,XN,XH,CT
CA
XN,XH,CA,CT
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
TT1
XN,XH
XN,XH
XN,XH
CA
CA
CA
CA
CA
CA
-
For photometric information, visit our website,
www.americanelectriclighting.com
TT7
XN,XH
XN,XH
XN,XH
CA
CA
CA
CA
CA
CA
-
TT3
XN,XH
XN,XH
XN,XH
CA
CA
CA
CA
CA
CA
-
347
XN,XH
XN,XH
XN,XH,CA
CA
CA
CA
CA
CA
CA
CA
-
DECORATIVE & POST-TOP LIGHTING
Heritage Collection ..................................................62
Heritage Poles ........................................................100
Marietta Series ....................................................62
Chadsworth Series............................................100
Sumter Series ......................................................64
New Albany Series ...........................................102
Cresthill Classic ...................................................66
Statesboro Series..............................................104
Cresthill Sphere ...................................................68
Waycross Series ...............................................106
Cresthill Centennial .............................................70
Accessories........................................................108
Cresthill Glass ......................................................72
Ballast Matrices .....................................................132
Lexington...............................................................74
Syracuse Series ..................................................76
Victorian Series ...................................................78
Yorktown ...............................................................80
Branson.................................................................82
Depot .....................................................................84
American Revolution Series 247............................86
American Revolution Cutoff Series 247 ................88
Contempo Series 245 ..............................................90
Residential Post Top Series RES............................92
TwistPackTM Series TWT.........................................94
Bainbridge Series 870 .............................................96
Georgian Series GRP ...............................................98
American Electric Lighting™
Heritage Collection
Marietta Series
35-250W HPS, 50-250W MH, 100-250W MV
PP RR O
OD
DU
U CC TT O
O VV EE RR VV II EE W
W
Features:
NEW
Available in solid or clear top prismatic globe.
Interchangeable base with a wide variety of globes.
Symmetric or Asymmetric distribution.
Available in Semi-Cutoff IES classification.
Injection-molded, high-impact acrylic or polycarbonate.
Excellent uniformity, light distribution and efficiency.
Maximizes pole spacing.
Base and optical ship separately.
HPS units standard with encapsulated starter that is located at the socket for
quick access.
Quick disconnect plug for easy maintenance.
Easy access component door.
Applications:
Photocontrol and terminal block available and located with easy access from
component door.
Streetscapes
Walkways
Pathways
Parks
Uplight shield option available.
E39 mogul base socket standard.
Mounts to 3” x 3” pole top tenons.
All electrical components warranted by AEL’s 6-year guarantee.
DIMENSIONS
Complies with ANSI: C136.2, C136.10, C136.15, C136.31.
15.9"
(404)
Suitable for -30°C MH & MV / -40°C HPS.
36"
(914)
9.13"
(232)
Effective Projected Area (EPA)
The EPA for the Marietta Series is 2.7 sq. ft.
Approx. Wt. = 24 lbs.
62
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage Collection
Marietta Series
35-250W HPS, 50-250W MH, 100-250W MV
O R D E R I N G
I N F O R M AT I O N
Example: L M D 1 7 M C A M T 1 R 5 P A P R P C U S
Wattage / Source
Series
LMD
Marietta
03
05
07
10
15
17
25
S
M
V
35W
50W
70W
100W
150W
175W
250W1
HPS
MH
MV
RN
RH
XN
XH
CA
CT
Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI
Refer to ballast matrix on page 132
for compatibility.
Distribution
Voltage
Ballast
120
208
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
DT2
120V
208V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120
Tri-tap wired 277
Tri-tap wired 347
Dual Tap 120/240
wired 120
Dual Tap 120/240
wired 240
R3 Type III
R5 Type V
Options
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Globe
PP
PA
PP
PN
Prismatic Polycarbonate solid top
(optical)
Prismatic Acrylic solid top (optical)
Prismatic clear top polycarbonate
(optical)
Prismatic clear top acrylic (optical)
Paint
(blank) Black
VG Verde Green
BZ Bronze
Receptacle
(blank) No photocontrol receptacle (std)
PR Photocontrol receptacle
PB Phosphor bronze contacts2
Terminal Block
(blank) Terminal Block (std)
T2 Wired to L1 & L2 Positions
T3 3 wire operations (L1, N, L2 Position)
Lamp
LC
LD
Notes:
1 250W adds 3” to housing height
2 For use with PR option
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Photocontrol
(blank) None
PC Twist-lock Photocontrol2
Misc
SH
SS
US
BD
TL
Shorting Cap2
Stainless Steel Fasteners (external)
Uplight Shield
Without decorative cage
Tool-less Entry
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
63
Heritage Collection
Sumter Series
35-250W HPS, 50-250W MH, 100-250W MV
P R O D U C T
O V E R V I E W
Features:
NEW
Solid top prismatic globe.
Interchangeable base with a wide variety of globes.
Symmetric or Asymmetric distribution.
Available in Semi-Cutoff IES classification.
Injection-molded, high-impact acrylic or polycarbonate.
Excellent uniformity, light distribution and efficiency.
Maximizes pole spacing.
Base and optical ship separately.
HPS units standard with encapsulated starter that is located at the socket for
quick access.
Quick disconnect plug for easy maintenance.
Easy access component door.
Photocontrol and terminal block available and located with easy access from
component door.
Applications:
Streetscapes
Walkways
Pathways
Parks
E39 mogul base socket standard.
Mounts to 3” x 3” pole top tenons.
All electrical components warranted by AEL’s 6-year guarantee.
Complies with ANSI: C136.2, C136.10, C136.15, C136.31.
DIMENSIONS
Suitable for -30°C MH & MV / -40°C HPS.
15.66"
(398)
39.25"
(970)
3.25"
(83)
Effective Projected Area (EPA)
The EPA for the Sumter Series is 2.7 sq. ft.
Approx. Wt. = 24 lbs.
64
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage Collection
Sumter Series
35-250W HPS, 50-250W MH, 100-250W MV
O R D E R I N G
I N F O R M AT I O N
Example: L S H 1 7 M C A 1 2 0 R 5 P A P R L C P C
Wattage / Source
Series
LSH
Sumter
03
05
07
10
15
17
25
S
M
V
35W
50W
70W
100W
150W
175W
250W1
HPS
MH
MV
RN
RH
XN
XH
CA
CT
Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI
Refer to ballast matrix on page 132
for compatibility.
Distribution
Voltage
Ballast
120
208
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
DT2
120V
208V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120
Tri-tap wired 277
Tri-tap wired 347
Dual Tap 120/240
wired 120
Dual Tap 120/240
wired 240
R3 Type III
R5 Type V
Options
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Globe
PP
PA
Prismatic Polycarbonate (optical)
Prismatic Acrylic (optical)
Paint
(blank) Black
VG Verde Green
BZ Bronze
Receptacle
(blank) No photocontrol receptacle (std)
PR Photocontrol receptacle
PB Phosphor Bronze Contacts2
Lamp
LC
LD
Notes:
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Photocontrol
(blank) None
PC Twist-lock Photocontrol2
Misc
SH
SS
TL
1 250W adds 3” to housing height
2 For use with PR option
Shorting Cap2
Stainless Steel Fasteners (external)
Tool-less Entry
Terminal Block
(blank) Terminal Block (std)
T2 Wired to L1 & L2 Positions
T3 3 wire operations (L1, N, L2 Position)
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
65
Heritage Collection
Cresthill Classic
35-250W HPS, 50-250W MH, 100-250W MV
P R O D U C T
O V E R V I E W
Features:
Interchangeable base with a wide variety of globes.
Symmetric or Asymmetric distribution.
Globe available in stepped acrylic and polycarbonate or prismatic acrylic and
polycarbonate.
Base and optical ship separately.
HPS units standard with encapsulated starter that is located at the socket for
quick access.
Quick disconnect plug for easy maintenance.
Easy access component door.
Photocontrol and terminal block available and located with easy access from
component door.
E39 mogul base socket standard.
Mounts to 3” x 3” pole top tenons.
Applications:
All electrical components warranted by AEL’s 6-year guarantee.
Streetscapes
Walkways
Pathways
Parks
Complies with ANSI: C136.2, C136.10, C136.15, C136.31.
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
13"
(330)
32"
(813)
3.25"
(83)
Effective Projected Area (EPA)
The EPA for the Cresthill Classic is 1.4 sq. ft.
Approx. Wt. = 37 lbs.
66
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage Collection
Cresthill Classic
35-250W HPS, 50-250W MH, 100-250W MV
O R D E R I N G
I N F O R M AT I O N
Example: L C R 1 0 S R N 1 2 0 R 5 A P P R L C P C
Wattage / Source
Series
LCR
Cresthill
03
05
07
10
15
17
25
S
M
V
35W
50W
70W
100W
150W
175W
250W1
Voltage
Ballast
HPS
MH
MV
RN
RH
XN
XH
CA
CT
Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI
Refer to ballast matrix on page 133
for compatibility.
120
208
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
DT2
120V
208V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120
Tri-tap wired 277
Tri-tap wired 347
Dual Tap 120/240
wired 120
Dual Tap 120/240
wired 240
Distribution
R0 No internal
refractor
R3 Type III2
R5 Type V2
Options
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Globe
AP
AA
PN
PT
Classic Large Clear Polycarbonate
(Non-optical)
Classic Large Clear Acrylic
(Non-optical)
Prismatic Polycarbonate (optical)
Prismatic Acrylic (optical)
Paint
(blank) Black
VG Verde Green
BZ Bronze
Receptacle
(blank) No photocontrol receptacle (std)
PR Photocontrol receptacle
PB Phosphor bronze contacts3
Terminal Block
(blank) Terminal Block (std)
T2 Wired to L1 & L2 Positions
T3 3 wire operations (L1, N, L2 Position)
Lamp
LC
LD
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Notes:
1 250W adds 3” to housing height
2 Achieved with internal glass refractor
except with prismatic globes
3 For use with PR options
4 For use with PA and PP only
Photocontrol
(blank) None
PC Twist-lock Photocontrol3
Misc
SH
SS
US
9R
TL
Shorting Cap3
Stainless Steel Fasteners (external)
Uplight Shield4
9" Globe neck
Tool-less Entry
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
67
Heritage Collection
Cresthill Sphere
35-250W HPS, 50-250W MH, 100-250W MV
P R O D U C T
O V E R V I E W
Features:
Interchangeable base with a wide variety of globes.
Symmetric or Asymmetric distribution.
Globe available in 22” white acrylic or clear polycarbonate.
Base and optical ship separately.
HPS units standard with encapsulated starter that is located at the socket
for quick access.
Quick disconnect plug for easy maintenance.
Easy access component door.
Photocontrol and terminal block available and located with easy access.
from component door.
E39 mogul base socket standard.
Mounts to 3” x 3” pole top tenons.
Powdercoat finish.
Applications:
All electrical components warranted by AEL’s 6-year guarantee.
Streetscapes
Walkways
Pathways
Parks
Complies with ANSI: C136.2, C136.10, C136.15, C136.31.
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
16"
(22)
26"
(660)
3.25"
(83)
Effective Projected Area (EPA)
The EPA for the Cresthill Sphere is 2.5 sq. ft.
Approx. Wt. = 22 lbs.
68
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage Collection
Cresthill Sphere
35-250W HPS, 50-250W MH, 100-250W MV
O R D E R I N G
I N F O R M AT I O N
Example: L C R 1 0 S R N 1 2 0 R 5 S Y P R L C P C
Wattage / Source
Series
LCR
Cresthill
03
05
07
10
15
17
25
S
M
V
35W
50W
70W
100W
150W
175W
250W1
Voltage
Ballast
HPS
MH
MV
RN
RH
XN
XH
CA
CT
Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI
Refer to ballast matrix on page 133
for compatibility.
120
208
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
DT2
120V
208V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120
Tri-tap wired 277
Tri-tap wired 347
Dual Tap 120/240
wired 120
Dual Tap 120/240
wired 240
Distribution
R0 No internal
retractor
R3 Type III2
R5 Type V2
Options
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Globe
SL
SY
Sphere Polycarbonate
Sphere Acrylic
Paint
(blank) Black
VG Verde Green
BZ Bronze
Receptacle
(blank) No photocontrol receptacle (std)
PR Photocontrol receptacle
PB Phosphor bronze contacts3
Lamp
LC
LD
Notes:
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Photocontrol
(blank) None
PC Twist-lock Photocontrol3
Misc
SH
SS
9R
TL
1 250W adds 3” to housing height
2 Achieved with internal glass refractor
3 For use with PR options
Shorting Cap3
Stainless Steel Fasteners (external)
9" Globe neck
Tool-less Entry
Terminal Block
(blank) Terminal Block (std)
T2 Wired to L1 & L2 Positions
T3 3 wire operations (L1, N, L2 Position)
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
69
Heritage Collection
Cresthill Centennial
35-250W HPS, 100-250W MH, 100-250W MV
P R O D U C T
O V E R V I E W
Features:
Interchangeable base with a wide variety of globes.
Symmetric or Asymmetric distribution.
Acrylic or polycarbonate globe.
Base and optical ship separately.
HPS units standard with encapsulated starter that is located at the socket.
for quick access.
Quick disconnect plug for easy maintenance.
Easy access component door.
Photocontrol and terminal block available and located with easy access
from component door.
E39 mogul base socket standard.
Mounts to 3” x 3” pole top tenons.
Powdercoat finish.
Applications:
All electrical components warranted by AEL’s 6-year guarantee.
Streetscapes
Walkways
Pathways
Parks
Complies with ANSI: C136.2, C136.10, C136.15, C136.31.
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
16"
(406)
32"
(813)
3.25"
(83)
Effective Projected Area (EPA)
The EPA for the Cresthill Centennial is 1.2 sq. ft.
Approx. Wt. = 22 lbs.
70
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage Collection
Cresthill Centennial
35-250W HPS, 100-250W MH, 100-250W MV
O R D E R I N G
I N F O R M AT I O N
Example: L C R 1 0 S R N 1 2 0 R 5 C Y P R L C P C
Wattage / Source
Series
LCR
Cresthill
03
05
07
10
15
17
25
35W
50W
70W
100W
150W
175W
250W1
S
M
V
Voltage
Ballast
HPS
MH
MV
RN
RH
XN
XH
CA
CT
Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI
Refer to ballast matrix on page 133
for compatibility.
120
208
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
DT2
120V
208V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120
Tri-tap wired 277
Tri-tap wired 347
Dual Tap 120/240
wired 120
Dual Tap 120/240
wired 240
Distribution
RO No internal
retractor
R3 Type III2
R5 Type V2
Options
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Globe
CE
CW
CY
CM
Centennial Large Clear Acrylic
(Non-optical)
Centennial Large White
Polycarbonate
Centennial Large Clear Acrylic
Centennial Medium Clear Acrylic
Paint
(blank) Black
VG Verde Green
BZ Bronze
Receptacle
(blank) No photocontrol receptacle (std)
PR Photocontrol receptacle
PB Phosphor bronze contacts3
Terminal Block
(blank) Terminal Block (std)
T2 Wired to L1 & L2 Positions
T3 3 wire operations (L1, N, L2 Position)
Lamp
LC
LD
Notes:
1 250W adds 3” to cast housing height
2 Achieved with internal glass refractor
3 For use with PR options
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Photocontrol
(blank) None
PC Twist-lock Photocontrol3
Misc
SH
SS
9R
TL
Shorting Cap3
Stainless Steel Fasteners (external)
9" Globe neck
Tool-less Entry
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
71
Heritage Collection
Cresthill Glass
35-250W HPS, 50-250W MH, 100-250W MV
P R O D U C T
O V E R V I E W
Features:
NEW
Interchangeable base with a wide variety of globes.
Symmetric or Asymmetric distribution.
Prismatic glass globe.
Base and optical ship separately.
HPS units standard with encapsulated starter that is located at the socket for
quick access.
Quick disconnect plug for easy maintenance.
Easy access component door.
Photocontrol and terminal block available and located with easy access from
component door.
E39 mogul base socket standard.
Mounts to 3” x 3” pole top tenons.
Powdercoat finish.
Applications:
All electrical components warranted by AEL’s 6-year guarantee.
Streetscapes
Walkways
Pathways
Parks
Complies with ANSI: C136.2, C136.10, C136.15, C136.31.
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
14"
(355)
28.5"
(724)
3.25"
(83)
Effective Projected Area (EPA)
The EPA for the Cresthill Glass is 1.4 sq. ft.
Approx. Wt. = 37 lbs.
72
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage Collection
Cresthill Glass
35-250W HPS, 50-250W MH, 100-250W MV
O R D E R I N G
I N F O R M AT I O N
Example: L C R 1 0 S R N 1 2 0 R 5 P G P R L C P C
Wattage / Source
Series
LCR
Cresthill
03
05
07
10
15
17
25
S
M
V
35W
50W
70W
100W
150W
175W
250W1
Voltage
Ballast
HPS
MH
MV
RN
RH
XN
XH
CA
CT
Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI
120
208
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
Refer to ballast matrix on page 133
for compatibility.
DT2
120V
208V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120
Tri-tap wired 277
Tri-tap wired 347
Dual Tap 120/240
wired 120
Dual Tap 120/240
wired 240
Distribution
R3 Type III
R5 Type V
Options
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Globe
PG
Prismatic Glass
Paint
(blank) Black
VG Verde Green
BZ Bronze
Receptacle
(blank) No photocontrol receptacle (std)
PR Photocontrol receptacle
PB Phosphor bronze contacts1
Lamp
LC
LD
Notes:
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Photocontrol
(blank) None
PC Twist-lock Photocontrol2
Misc
SH
SS
9R
TL
1 250 W adds 3” to cast housing height
2 For use with PR options
Shorting Cap2
Stainless Steel Fasteners (external)
9" Globe neck
Tool-less Entry
Terminal Block
(blank) Terminal Block (std)
T2 Wired to L1 & L2 Positions
T3 3 wire operations (L1, N, L2 Position)
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
73
Heritage Collection
Lexington
35-250W HPS, 50-250W MH, 100-250W MV
P R O D U C T
O V E R V I E W
Features:
Available with or without spikes.
Interchangeable base with a wide variety of lenses.
Symmetric or Asymmetric distribution.
Decorative spike finial standard.
Rugged cast-aluminum housing.
Lens available in acrylic, polycarbonate or clear glass.
Base and optical ship separately.
HPS units standard with encapsulated starter that is located at the socket for
quick access.
Quick disconnect plug for easy maintenance.
Easy access component door.
Photocontrol and terminal block available and located with easy access from
component door.
Applications:
E39 mogul base socket standard.
Streetscapes
Walkways
Pathways
Parks
Mounts to 3” x 3” pole top tenons.
All electrical components warranted by AEL’s 6-year guarantee.
Complies with ANSI: C136.2, C136.10, C136.15, C136.31.
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
18.5"
(470)
44"
(1118)
3.25"
(83)
Effective Projected Area (EPA)
The EPA for the lexington is 3.1 sq. ft.
Approx. Wt. = 33 lbs.
74
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage Collection
Lexington
35-250W HPS, 50-250W MH, 100-250W MV
O R D E R I N G
I N F O R M AT I O N
Example: L L X 1 0 S R N 1 2 0 R 5 A Y P R L C P C
Series
LLX
Lexington
Wattage / Source
03
05
07
10
15
17
25
S
M
V
35W
50W
70W
100W
150W
175W
250W1
Voltage
Ballast
HPS
MH
MV
RN
RH
XN
XH
CA
CT
120
208
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI
Refer to ballast matrix on page 133
for compatibility.
DT2
120V
208V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120
Tri-tap wired 277
Tri-tap wired 347
Dual Tap 120/240
wired 120
Dual Tap 120/240
wired 240
Distribution
R3 Type III
R5 Type V
Options
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Globe
AY
PY
GL
Acrylic
Polycarbonate
Glass
Paint
(blank) Black
VG Verde Green
BZ Bronze
Receptacle
(blank) No photocontrol receptacle (std)
PR Photocontrol receptacle
PB Phosphor Bronze Contacts2
Lamp
LC
LD
Notes:
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Photocontrol
(blank) None
PC Twist-lock Photocontrol2
Misc
SH
SS
NS
TL
1 250 W adds 3” to cast housing height
2 For use with PR option
Shorting Cap2
Stainless Steel Fasteners (external)
No spikes on LLX housing
Tool-less Entry
Terminal Block
(blank) Terminal Block (std)
T2 Wired to L1 & L2 Positions
T3 3 wire operations (L1, N, L2 Position)
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
75
Heritage Collection
Syracuse Series
35-250W HPS, 50-250W MH, 100-250W MV
P R O D U C T
O V E R V I E W
Features:
Attractive cast-aluminum decorative cage.
Interchangeable base with a wide variety of globes.
Symmetric or Asymmetric distribution.
Available in solid top prismatic acrylic or polycarbonate, and stippled acrylic
or polycarbonate.
Powdercoat finish.
HPS units standard with encapsulated starter that is located at the socket for
quick access.
Quick disconnect plug for easy maintenance.
Easy access component door.
Photocontrol and terminal block available and located with easy access from
component door.
E39 mogul base socket standard.
Applications:
Mounts to 3” x 3” pole top tenons .
Streetscapes
Walkways
Pathways
Parks
All electrical components warranted by AEL’s 6-year guarantee.
Complies with ANSI: C136.2, C136.10, C136.15, C136.31.
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
16"
(406)
34"
(864)
3.25"
(83)
Effective Projected Area (EPA)
The EPA for the Syracuse Series is 1.5 sq. ft.
Approx. Wt.. = 26 lbs.
76
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage Collection
Syracuse Series
35-250W HPS, 50-250W MH, 100-250W MV
O R D E R I N G
I N F O R M AT I O N
Example: L S Y O 7 S R H 1 2 0 R 3 A Y L C
Wattage / Source
Series
LSY
Syracuse
03
05
07
10
15
17
25
S
M
V
35W
50W
70W
100W
150W
175W
250W1
HPS
MH
MV
RN
RH
XN
XH
CA
CT
Distribution
Voltage
Ballast
120
208
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI
Refer to ballast matrix on page 134
for compatibility.
DT2
120V
208V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120
Tri-tap wired 277
Tri-tap wired 347
Dual Tap 120/240
wired 120
Dual Tap 120/240
wired 240
RO No internal
retractor
R3 Type III2
R5 Type V2
Options
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Globe
LSY Series
AY Acrylic
PY Polycarbonate
PA Solid top prismatic acrylic
PP Solid top prismatic polycarbonate
Paint
(blank) Black
VG Verde Green
BZ Bronze
Receptacle
(blank) No photocontrol receptacle (std)
PR Photocontrol receptacle
PB Phosphor Bronze Contacts3
Terminal Block
(blank) Terminal Block (std)
T2 Wired to L1 & L2 Positions
T3 3 wire operations (L1, N, L2 Position)
Lamp
LC
LD
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Notes:
1 250 W adds 3” to cast housing height
2 Achieved with internal glass refractor
except with prismatic globes
3 For use with PR option
Photocontrol
(blank) None
PC Twist-lock Photocontrol3
Misc
SH
SS
TL
Shorting Cap3
Stainless Steel Fasteners (external)
Tool-less Entry
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
77
Heritage Collection
Victorian Series
35-250W HPS, 50-250W MH, 100-250W MV
P R O D U C T
O V E R V I E W
Features:
Symmetric or Asymmetric distribution.
Ships as a single unit.
Powdercoat finish.
Globe available in acrylic and polycarbonate.
Interchangeable base with a wide variety of globes.
HPS units standard with encapsulated starter that is located at the socket for
quick access.
Quick disconnect plug for easy maintenance.
Easy access component door.
Photocontrol and terminal block available and located with easy access from
component door.
E39 mogul base socket standard.
Mounts to 3” x 3” pole top tenons.
Applications:
All electrical components warranted by AEL’s 6-year guarantee.
Streetscapes
Walkways
Pathways
Parks
Complies with ANSI: C136.2, C136.10, C136.15, C136.31.
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
15"
(381)
48"
(1219)
3.25"
(83)
Effective Projected Area (EPA)
The EPA for the Victorian Series is 2.2 sq. ft.
Approx Wt. = 40 lbs.
78
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage Collection
Victorian Series
35-250W HPS, 50-250W MH, 100-250W MV
O R D E R I N G
I N F O R M AT I O N
Example: L V I 1 0 S R N 1 2 0 R 3 A Y
Wattage / Source
Series
LVI
Victorian
03
05
07
10
15
17
S
M
V
35W
50W
70W
100W
150W
175W
HPS
MH
MV
RN
RH
XN
XH
CA
CT
Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI
Refer to ballast matrix on page 134
for compatibility.
Distribution
Voltage
Ballast
120
208
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
DT2
120V
208V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120
Tri-tap wired 277
Tri-tap wired 347
Dual Tap 120/240
wired 120
Dual Tap 120/240
wired 240
RO No internal
refractor
R3 Type III1
R5 Type V1
Options
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Globe
AY
PY
Acrylic
Polycarbonate
Paint
(blank) Black
VG Verde Green
BZ Bronze
Receptacle
(blank) No photocontrol receptacle (std)
PR Photocontrol receptacle
PB Phosphor Bronze Contacts2
Lamp
LC
LD
Notes:
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Photocontrol
(blank) None
PC Twist-lock Photocontrol2
Misc
SH
SS
TL
1 Achieved with internal glass
refractor
2 For use with PR option
Shorting Cap2
Stainless Steel Fasteners (external)
Tool-less Entry
Terminal Block
(blank) Terminal Block (std)
T2 Wired to L1 & L2 Positions
T3 3 wire operations (L1, N, L2 Position)
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
79
Heritage Collection
Yorktown
35-250W HPS, 50-250W MH, 100-250W MV
P R O D U C T
O V E R V I E W
Features:
Symmetric or Asymmetric distribution.
Available in semi-cutoff IES classification.
Rugged cast-aluminum housing.
Button photocontrol available.
Ships as single unit.
Lens available in clear acrylic or polycarbonate.
E39 mogul base socket standard.
Powdercoat finish.
All electrical components warranted by AEL’s 6-year guarantee.
Complies with ANSI: C136.2, C136.10, C136.15, C136.31.
Suitable for -30°C MH & MV / -40°C HPS.
Applications:
Streetscapes
Walkways
Pathways
Parks
DIMENSIONS
20"
(508)
39"
(991)
3.25"
(83)
Effective Projected Area (EPA)
The EPA for the Yorktown is 2.8 sq. ft.
Approx. Wt. = 42 lbs.
80
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage Collection
Yorktown
35-250W HPS, 50-250W MH, 100-250W MV
O R D E R I N G
I N F O R M AT I O N
Example: L Y T 1 0 S R N 1 2 0 R 3 A Y L C
Series
LYT
Yorktown
Wattage / Source
03
05
07
10
15
17
25
35W
50W
70W
100W
150W
175W
250W1
S
M
V
Voltage
Ballast
HPS
MH
MV
RN
RH
XN
XH
CA
CT
120
208
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI
Refer to ballast matrix on page 135
for compatibility.
DT2
120V
208V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120
Tri-tap wired 277
Tri-tap wired 347
Dual Tap 120/240
wired 120
Dual Tap 120/240
wired 240
Distribution
RO No internal
retractor
R3 Type III2
R5 Type V2
Options
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Globe
AY
PY
Acrylic
Polycarbonate
Paint
(blank) Black
VG Verde Green
BZ Bronze
Lamp
LC
LD
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Photocontrol
(blank) None
BC Button Photocontrol
Misc
SS
TL
Notes:
1 250 W adds 3” to cast housing height
2 Achieved with internal glass refractor
Stainless Steel Fasteners (external)
Tool-less Entry
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
81
Heritage Collection
Branson
35-250W HPS, 50-250W MH, 100-250W MV
P R O D U C T
O V E R V I E W
Features:
Ornamental aluminum canopy top.
Interchangeable base with a wide variety of globes.
Symmetric or Asymmetric distribution.
Base and optical ship separately.
Powdercoat finish.
Base and optical ship separately.
HPS units standard with encapsulated starter that is located at the socket for
quick access.
Quick disconnect plug for easy maintenance.
Easy access component door.
Photocontrol and terminal block available and located with easy access from
component door.
E39 mogul base lamp holder standard.
Applications:
Mounts to 3” x 3” pole top tenons.
Streetscapes
Walkways
Pathways
Parks
Available in stippled acrylic or polycarbonate globes.
All electrical components warranted by AEL’s 6-year guarantee.
Complies with ANSI: C136.2, C136.10, C136.15, C136.31.
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
13"
(330)
38"
(965)
3.25"
(83)
Effective Projected Area (EPA)
The EPA for the Branson is 2.3 sq. ft.
Approx. Wt. = 22 lbs.
82
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage Collection
Branson
35-250W HPS, 50-250W MH, 100-250W MV
O R D E R I N G
I N F O R M AT I O N
Example: L B R 1 5 S C A M T 1 R 5 P Y L C
Series
LBR
Branson
Wattage / Source
03
05
07
10
15
17
25
35W
50W
70W
100W
150W
175W
250W1
S
M
V
Voltage
Ballast
HPS
MH
MV
RN
RH
XN
XH
CA
CT
120
208
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI
Refer to ballast matrix on page 135
for compatibility.
DT2
120V
208V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120
Tri-tap wired 277
Tri-tap wired 347
Dual Tap 120/240
wired 120
Dual Tap 120/240
wired 240
Distribution
R3 Type III2
R5 Type V2
Options
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Globe
LBR Series
AY Acrylic
PY Polycarbonate
Terminal Block
(blank) Terminal Block (std)
T2 Wired to L1 & L2 Positions
T3 3 wire operations (L1, N, L2 Position)
Paint
(blank) Black
VG Verde Green
BZ Bronze
Lamp
LC
LD
Receptacle
(blank) No photocontrol receptacle (std)
PR Photocontrol receptacle
PB Phosphor Bronze Contacts3
Notes:
1 250 W adds 3” to cast housing height
2 Achieved with internal glass refractor
3 For use with PR option
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Photocontrol
(blank) None
PC Twist-lock Photocontrol3
Misc
SH
SS
TL
Shorting Cap3
Stainless Steel Fasteners (external)
Tool-less Entry
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
83
Heritage Collection
Depot
35-250W HPS, 50-250W MH, 100-250W MV
PP RR OO DD UU CC TT OO VV EE RR VV I I EE W
W
Features:
Suspended mount fixture.
Powdercoat finish.
Button photocontrol.
Symmetric distribution.
Arm ordered separately.
Base, globe, and reflector ship separately.
IES Cutoff classification.
E39 mogul base socket standard.
All electrical components warranted by AEL’s 6-year guarantee.
Complies with ANSI: C136.2, C136.10, C136.15, C136.31.
Suitable for -30°C MH & MV / -40°C HPS.
Applications:
Streetscapes
Walkways
Pathways
Parks
DIMENSIONS
25"
(635)
49"
(1245)
32"
(813)
Effective Projected Area (EPA)
The EPA for the Depot is 3.7 sq. ft.
Approx. Wt. = 28 lbs.
Arm ordered separately
84
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage Collection
Depot
35-250W HPS, 50-250W MH, 100-250W MV
N GG II N
N FF OO RR M
M AA TT II OO N
N
OO RR DD EE RR II N
Example: L D P 1 5 S C A 1 2 0 R 5 A Y B C
LDP
Depot
Ballast
Wattage / Source
Series
03
05
07
10
15
17
25
35W
50W
70W
100W
150W
175W
250W
S
M
V
HPS
MH
MV
RN
RH
XN
XH
CA
CT
Reactor Normal
Power Factor
Reactor High
Power Factor
High Reactance/Lag NPF
High Reactance/Lag HPF
CWA Auto-Reg
CWI
Refer to ballast matrix on page 135
for compatibility.
Voltage
120
208
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
DT2
120V
208V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120
Tri-tap wired 277
Tri-tap wired 347
Dual Tap 120/240
wired 120
Dual Tap 120/240
wired 240
Distribution
R3 Type III
R5 Type V
Options
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Globe
AY
PY
Acrylic
Polycarbonate
Paint
(blank) Black
VG Verde Green
BZ Bronze
Lamp
LC
LD
Photocontrol
(blank) None
BC Button Photocontrol
Misc
SS
Stainless Steel Fasteners (external)
Lamp Included, Clear
Lamp Included, Deluxe/Coated
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
85
American Revolution
Series 247
50-150W HPS, 100-175W MV, 175W MH
P R O D U C T
O V E R V I E W
Features:
Die-cast aluminum housing and hood for long-life performance.
Optical assembly designed for maximum performance.
Hinged hood and captive screw provision afford quick, easy access to
electrical and optical area for relamping or servicing.
Slipfitter with three set screws allows secure installation to pole sizes 2-3/8"
or 3" OD.
E39 mogul base socket standard.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Complies with ANSI: C136.2, C136.10, C136.15, C136.3.1
Suitable for -30°C MH & MV / -40°C HPS.
Applications:
Streetscapes
Walkways
Pathways
Parks
DIMENSIONS
17"
(432)
25.5"
(648)
Effective Projected Area (EPA)
The EPA for the American Revolution Series 247 is 1.6 sq. ft.
Approx. Wt. = 36 lbs.
86
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
American Revolution
Series 247
50-150W HPS, 100-175W MV, 175W MH
O R D E R I N G
I N F O R M AT I O N
Example: 2 4 7 1 5 S R N 1 2 0 R 5 A Y E C
Wattage / Source
Series
247 American
Revolution
Post Top
05
07
10
15
17
00
50W
70W
100W
150W
175W
Incandescent
S
M
V
X
Voltage
Ballast
HPS
MH
MV
Incandescent
(order with XX
ballast option)
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance / Lag
Normal Power Factor
XH High Reactance / Lag
High Power Factor
CA CWA Autotransformer
CT CWI Autotransformer
MR Mag Reg (3 coil)1
XX No Ballast
Refer to ballast matrix on
page 136 for compatibility.
120
208
220
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
DT2
DT3
Options
DT4
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Paint4
(blank)
GY
WH
BZ
Black (standard)
Gray
White
Bronze
Lamp
LC
LD
LG
Starter8
Terminal Block
(blank)
(blank) Terminal Block (standard)
EC
T2 Wired to L1 & L2 Position
OP
T3 3 Wire Operation (L1, N, L2 Position)
SN
Listing
UL
CS
Fusing5
SF
DF
UL Listed
CSA Certified
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle6
PB Phosphor Bronze Contacts
Misc.
PC
SS
5H
NL
HS
WS
PU
TL
120V
208V
220V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired
277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual Tap 120/240
wired 120V
Dual Tap 120/240
wired 240V
Dual Tap 240/480
wired 240V
Dual Tap 240/480
wired 480V
Distribution
R2
R3
R5
RV
Type II
Type III
Type V2
Type V3
Optics
AY Acrylic
PY Polycarbonate
Refer to Optical Matrix
below for compatibility
Notes:
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Self-igniting Lamp7
1
2
3
4
Open Board (standard)
Encapsulated Plug-in
Open Plug-in
No ignitor (use self-igniting lamp)
Photocontrol Included per
Voltage Specified
Stainless Steel Hardware
50 Hertz Ballast Cycle9
NEMA Label (2x2)
Houseside Shield
Wildlife Shield (cupola)
Without Cupola
Tool-less Entry
5
6
7
8
9
MR not available with UL and CSA listing
Four white panels
Four clear panels
Other colors available, please contact your local
American Electric Lighting representative
Voids UL/CSA Certified Options not available
with multi-tap voltage options
PB, PC, SH not available with PR option
Requires SN option
HPS only
Limited availability, please contact your local
American Electric Lighting representative
Optic Distribution
05S
07S
10S
15S
17M
17V
R2 AY R3 AY R5 AY RV AY R2 PY
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
See pages 259-264 for a complete listing
of Frequently Ordered Products
R3 PY R5 PY RV PY
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
Product Guide
87
American Revolution Cutoff
Series 247
50-150W HPS
P R O D U C T
O V E R V I E W
Features:
NEW
Die-cast aluminum housing and hood for long-life performance.
Optical assembly designed for maximum performance.
Hinged hood and captive screw provision afford quick, easy access to
electrical and optical area for relamping or servicing.
Slipfitter with three set screws allows secure installation to pole sizes
2-3/8" or 3" OD.
Meets IESNA Full Cutoff classification.
All electrical components warranted by American Electric Lighting's
6-year guarantee.
Complies with ANSI: C136.2, C136.10, C136.15, C136.16.
Applications:
Streetscapes
Walkways
Pathways
Parks
DIMENSIONS
ZONAL LUMEN SUMMARY
Zone
Downward Street Side
Downward House Side
Downward Total
Upward Street Side
Upward House Side
Upward Total
Total
17"
(432)
25.5"
(648)
Effective Projected Area (EPA)
The EPA for the American Revolution Series 247 is 1.6 sq. ft.
Approx. Wt. = 36 lbs.
88
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Lumens
3206.3
1983.3
5189.6
0.0
0.0
0.0
5189.6
%Lamp
33.8
20.9
54.6
0.0
0.0
0.0
54.6
American Revolution Cutoff
Series 247
50-150W HPS
O R D E R I N G
I N F O R M AT I O N
Example: 2 4 7 1 5 S R N 1 2 0 R 2 F C P C
Wattage / Source
Series
247 American
Revolution
Post Top
05
07
10
15
50W
70W
100W
150W
S HPS
Voltage
Ballast
RN Reactor Normal
XX No Ballast
120 120V
Distribution
R2 Type II
Optics
FC Full Cut-off
Options
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Paint1
(blank)
GY
WH
BZ
Black (standard)
Gray
White
Bronze
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Position
Fusing
SF
Single Fuse
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle2
PB Phosphor Bronze Contacts
Lamp
LC
LD
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Starter
(blank)
Open Board (standard)
Misc.
PC
SS
NL
WS
SH
PU
TL
Notes:
1
2
Other colors available, please contact your local
American Electric Lighting representative
PB, PC, SH not available with PR option
Photocontrol Included per
Voltage Specified
Stainless Steel fasteners (external)
NEMA Label (2x2)
Wildlife Shield (cupola)
Shorting Cap
Without Cupola
Tool-less Entry
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
89
Contempo
Series 245
35-400W HPS, 100-400W MV, 70-400 MH
P R O D U C T
O V E R V I E W
Features:
Die-cast aluminum housing and spun aluminum hood for long-life
performance.
Optical assembly designed for maximum performance.
Multi-gasketing to provide weatherproof protection of optical assembly for full
illumination performance.
Hinged hood and captive screw latching provision afford quick, easy access to
electrical and optical area for relamping or servicing.
Available with two different style hoods and an added scroll option for a more
decorative look.
Cone mounting fitter with three set screws allows secure installation to pole
sizes 2-3/8" or 3" OD.
Refractor available in tempered glass, acrylic and polycarbonate.
Available in a variety of IES light distributions patterns.
E39 mogul base socket standard.
Applications:
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Streetscapes
Walkways
Pathways
Parks
Complies with ANSI: C136.2, C136.10, C136.15, C136.16.
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
22"
(559)
22"
(559)
25-1/2"
(648)
20"
(508)
3-1/4"
(83)
3-1/4"
(83)
STYLE A
STYLE D
Effective Projected Area (EPA)
The EPA for the Contempo Series 245 is 1.3 sq. ft.
Approx. Wt. = 32 lbs.
DIMENSIONS
22"
(559)
22"
(559)
25-1/2"
(648)
20"
(508)
3-1/4"
(83)
3-1/4"
(83)
STYLE A
STYLE D
Effective Projected Area (EPA)
The EPA for the Decorative Scroll Option is 1.8 sq. ft.
Approx. Wt. = 32 lbs.
90
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Contempo
Series 245
35-400W HPS, 100-400W MV, 70-400W MH
O R D E R I N G I N F O R M AT I O N
O R D E R I N G I N F O R M AT I O N
Example: 2 4 5 1 0 S R N 1 2 0 R 3 G L S D P C
Wattage / Source
Series
245 Contempo
Post Top
03
05
07
10
13
14
15
17
20
25
31
40
35W
50W
70W
100W
130W
140W
150W
175W
200W
250W
310W
400W
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance / Lag
Normal Power Factor
XH High Reactance / Lag
High Power Factor
CA CWA Autotransformer
CT CWI Autotransformer
MR Mag Reg (3 coil)
XX No Ballast
S HPS
M MH
V MV
Refer to ballast matrix on
page 136 for compatibility.
Options
Distribution
Voltage
Ballast
120
208
220
230
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
DT2
DT3
DT4
120V
208V
220V
230V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual Tap 120/240 wired 120V
Dual Tap 120/240 wired 240V
Dual Tap 240/480 wired 240V
Dual Tap 240/480 wired 480V
R2
R3
R4
R5
Type II
Type III
Type IV
Type V
Optics
GL Glass
AY Acrylic
PY Polycarbonate
Refer to Optical Matrix
below for compatibility
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Paint1
(blank)
BK
WH
BZ
Gray (standard)
Black
White
Bronze
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation (L1, N, L2 Position)
Listing
UL
CS
UL Listed
CSA Certified
Fusing2
SF
DF
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle3
PB Phosphor Bronze Contacts
Lamp
LC
LD
LG
Starter5
(blank)
EC
OP
SN
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Self-igniting Lamp4
Open Board (standard)
Encapsulated Plug-in
Open Plug-in
No ignitor (use self-igniting lamp)
Hood Style (see line art)
(blank) Style A
SD Style D
Notes:
1
2
Misc.
PC
Photocontrol Included per
Voltage Specified
Stainless Steel Hardware
50 Hertz Ballast Cycle6
NEMA Label
Decorative Scroll Design (Standard Black)
Shorting Cap
SS
5H
NL
DD
SH
3
4
5
6
Other colors available, please contact your local
American Electric Lighting representative
Voids UL/CSA not available in MT, TT, DT,
voltages
PB, PC, SH not available with NR option
Requires SN option
Available in HPS only
Limited availability, please contact your local
American Electric Lighting representative
Optic Distribution
03S
05S
07S
10S
15S
20S
25S
31S
40S
17M
25M
40M
17V
25V
40V
R2 AY R3 AY R4 AY R5 AY R2 PY R3 PY
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
-
See pages 259-264 for a complete listing
of Frequently Ordered Products
R4 PY
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
-
R5 PY R2 GL
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
R3 GL R5 GL
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
Product Guide
91
Residential Post Top
Series RES
35-70W HPS
P R O D U C T
O V E R V I E W
Features:
NEW
Compact post top light, ideal for retrofitting inefficient incandescent units.
Attractive, complements virtually any style architecture.
Easy access to lamp compartment for quick relamping.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Complies with ANSI: C136.2, C136.10, C136.15, C136.16.
Applications:
Residential areas
Architectural landscape lighting
Recreational areas
Commercial environments
Parks, Walkways
DIMENSIONS
17.75"
(451)
9.50"
(241)
Effective Projected Area (EPA)
The EPA for the RES is 2.93 sq. ft.
Approx. Wt. = 8 lbs.
92
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Residential Post Top
Series RES
35-70W HPS
O R D E R I N G
I N F O R M AT I O N
Example: R E S O 5 S R N 1 2 0 R 5 P Y
Wattage / Source
Series
RES Residential
Post Top
00
03
05
07
S
Use for
incandescent
35W
50W
70W
Voltage
Ballast
HPS
RN
Reactor NPF
120
120V
Optics
Distribution
R5 Type
PY
Polycarbonate
Options
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Color
(blank)
Black (standard)
Lamp
LC
LD
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Photocontrol
(blank) Button Photocontrol
(standard)
NC No photocontrol
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
93
TwistPackTM
Series TWT
50-150W HPS
P R O D U C T
O V E R V I E W
Features:
NEW
Unique twistlock feature with locking screw that allows easy removal of
optical assembly from slipfitter casting.
Slipfitter casting houses ballast. It will fit over a post having top diameter of
3-1/2” (4”OD) or 3” (3-1/2OD).
Slipfitter casting is secured to post by three Allen-head locking screws.
Some components of the ballast (e.g. capacitors and/or ignitors) depending
on wattage or type, may extend below the slipfitter casting and may have to
fit in the top of the pole.
Aluminum hoods are available in either 24” or 28” diameter.
Refractors offered in IES Type II, and V distributions.
Available in polycarbonate or acrylic refractors.
Mogul base socket.
Natural aluminum finish.
NEMA type photocell receptacle is standard.
Applications:
CSA certified option available.
Shopping Malls
Parks
Campuses
Residential Streets
Condominiums
Walkways
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Complies with ANSI: C136.2, C136.10, C136.15, C136.16.
DIMENSIONS
28.63"
(727)
24.38"
(619)
24.75"
(629)
26.63"
(676)
Effective Projected Area (EPA)
The EPA for the TwistPack is 1.88 sq. ft.
Approx. Wt. = 41 lbs.
94
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
TwistPackTM
Series TWT
50-150W HPS
O R D E R I N G
I N F O R M AT I O N
Example: T W T 1 5 S R N 1 2 0 R 5 A Y H 8
Wattage / Source
Series
TWT TwistPack
05
07
10
15
17
25
00
50W
M
70W
S
100W
V
150W
X
175W
250W
Use for
incandescent
Metal Halide
HPS
Mercury Vapor
Incandescent
CA CWA
Autotransformer
CT CWI
Autotransformer
RH Reactor High
Power Factor
RN Reactor Normal
Power Factor
XH High Reactance/Lag
High Power Factor
XN High Reactance/Lag
Normal Power Factor
XX No Ballast
Refer to ballast matrix on
page 137 for compatibility.
Distribution
Voltage
Ballast
120
208
240
277
347
600
DT1
DT2
MT1
MT2
MT7
MT8
TT1
TT3
TT7
R2
120V
R5
208V
240V
277V
347V
600V
Dual Tap 120/240 wired 120
Dual Tap 120/240 wired 240
Multi-tap wired 120
Multi-tap wired 240
Multi-tap wired 277
Multi-tap wired 208
Tri-tap wired 120
Tri-tap wired 347
Tri-tap wired 277
Roadway Type II
Type V
Optics
AY Acrylic
PY Polycarbonate1
Hood
H4
H8
24” hood
28” hood
Options
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Terminal Block
Photocontrol Receptacle
T2 Wired to L1 & L2 Positions
(blank) NEMA Photocontrol
T3 3 Wire Operation (L1, N, L2 Position)
Receptacle (standard)
NR No Photocontrol Receptacle3
Listing
CS CSA Certified
Lamp
LC Lamp Included, Clear
Supply Wire
LD Lamp Included, Deluxe/Coated
PW Pre-wire (slip fitter only)
PW15 Pre-wire for attached
Starter4
PW20 #14 CU SOLID B/W
EC Encapsulated Plug-in
PW25 #14 CU SOLID B/W
OP Open Plug-in
PA15 #10 CU SOLID B/W
PA20 #10 CU SOLID B/W
Misc.
PA25 #10 CU SOLID B/W
PC Photocontrol Included per
PB15 #10 CU SOLID B/B
voltage specified
PB20 #10 CU SOLID B/B
NL NEMA Label
PB25 #10 CU SOLID B/B
SH Shorting Cap
PC15 #10 CU SOLID B/B/W
SS Stainless Steel Hardware
PC20 #10 CU SOLID B/B/W
PC25 #10 CU SOLID B/B/W
PD15 #10 CU STRAND B/W
PD20 #10 CU STRAND B/W
PD25 #10 CU STRAND B/W
PE15 #10 CU STRAND B/W
PE20 #10 CU STRAND B/B
PE25 #10 CU STRAND B/B
PF15 #10 CU STRAND B/B/W
PF620 #10 CU STRAND B/B/W
PF25 #10 CU STRAND B/B/W
PG15 #12 CU SOLID B/W
See pages 259-264 for a complete listing
of Frequently Ordered Products
Notes:
1
2
3
4
PY available in HPS only
H4 available in 175W and below
PC and SH not available with NR option
HPS only
Product Guide
95
Bainbridge
Series 870
50-150W HPS,100-175W MV, 175W MH
P R O D U C T
O V E R V I E W
Features:
NEW
Architecturally complementary design.
Powdercoated, paint finish.
Terminal block for ease of wiring.
A variety of wattages and ballast types.
Available in HPS,MH, and MV.
Easy access to electrical components.
Available in a variety of IES distributions.
E39 mogul base socket standard.
All electrical components warranted by AEL’s 6-year guarantee.
Complies with ANSI: C136.2, C136.10, C136.15, C136.31.
Suitable for -30°C MH & MV / -40°C HPS.
Applications:
Office Buildings
Shopping centers
Malls
Apartment/condominium complexes
Commercial developments
DIMENSIONS
16.5"
(419)
27"
(686)
37"
(940)
Effective Projected Area (EPA)
The EPA for the Bainbridge Series 870 is 3.7 sq. ft.
Approx. Wt. = 28 lbs.
96
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Bainbridge
Series 870
50-150W HPS,100-175W MV, 175W MH
O R D E R I N G
I N F O R M AT I O N
Example: 8 7 0 1 0 S C A M T 1 R 3 A Y L C
Series
870
Bainbridge
Wattage / Source
05
07
10
15
17
50W
70W
100W
150W
175W
S HPS
M MH
V MV
Voltage
Ballast
CA CWA Autotransformer
RH Reactor High
Power Factor
RN Reactor Normal
Power Factor
XH High Reactance / Lag
High Power Factor
XN High Reactance / Lag
Normal Power Factor
CT CWI Autotransformer
Refer to ballast matrix on page 137
for compatibility.
120
208
240
277
347
480
DT1
120V
208V
240V
277V
347V
480V
Dual Tap 120/240
wired 120
Dual Tap 120/240
wired 240
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120
Tri-tap wired 277
Tri-tap wired 347
DT2
MT1
MT8
MT2
MT7
TT1
TT7
TT3
Distribution
R3 Type III
R5 Type V
R0 No internal
refractor
Optics
AY Acrylic
PY Polycarbonate
Options
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Paint
(blank)
BZ
VG
Black (standard)
Bronze
Antique Verde Green
Terminal Block
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation (L1, N, L2 Position)
Lamp
LC
LD
Photocontrol
(blank) None
BC Button-photocontrol
Misc.
FR
SS
NL
9R
Notes:
1
Achieved with internal glass refractor
Decorative Frond
Stainless Steel Hardware
NEMA Label
9”Globe neck
Lamp Included, Clear
Lamp Included, Deluxe/Coated
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
97
Georgian
Series GRP
50-150W HPS, 50 - 175W MV/MH
P R O D U C T
O V E R V I E W
Features:
NEW
Two (2) piece cast aluminum housing.
Castings are hinged and open with a simple 1/4 turn thumb screw for easy
maintenance.
Choice of 2 mounting arrangements: side entry or post top.
Wide choice of optical systems, see optical system options for proper IES
distribution.
All options windows are sealed with neoprene gaskets to prevent ingress of dirt
or moisture in luminaire. Bottom lens is sealed with a felt gasket for proper
breathing of luminaire (top entry and side entry units only).
All ballasts are mounted on a ballast plate with quick disconnect, for easy
replacement.
All exposed screws are stainless steel.
Cast aluminum slipfitter accepts 3” to 3-1/2” OD X 4” long tenon or pole. Mounting
hardware included.
A photocell cupola is supplied when ordering the photocell receptacle (only
available with post top (GRT) and side entry (GRS) models).
Applications:
Mogul base socket.
Residential areas
Architectural landscape lighting
Parks, walkways
Recreational areas
Commercial environments
Certified by CSA to CSA and UL standards.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Complies with ANSI: C136.2, C136.10, C136.15, C136.16
DIMENSIONS
19.6"
(498)
34.9"
(886)
4.1"
(104)
Effective Projected Area (EPA)
The EPA for the Georgian is 2.93 sq. ft.
Approx. Wt. = 46 lbs.
98
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Georgian
Series GRP
50-150W HPS, 50 - 175W MV/MH
O R D E R I N G
I N F O R M AT I O N
Example: G R P 1 0 S R H 1 2 0 R 3 P Y L C
GRP Georgian
Ballast
Wattage / Source
Series
05
10
15
17
50W
100W
150W
175W
CA CWA Autotransformer
CT CWI Autotransformer
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance / Lag
Normal Power Factor
XH High Reactance / Lag
High Power Factor
MR Mag-Reg (3 coil)
M MH
S HPS
V MV
Refer to ballast matrix on page 138
for compatibility.
Distribution
Voltage
120
208
240
277
347
DT1
DT2
MT1
MT2
MT7
MT8
TT1
TT3
TT7
120V
208V
240V
277V
347V
Dual Tap 120/240 wired 120
Dual Tap 120/240 wired 240
Multi-tap wired 120
Multi-tap wired 240
Multi-tap wired 277
Multi-tap wired 208
Tri-tap wired 120
Tri-tap wired 347
Tri-tap wired 277
R2 Roadway Type II
R3 Type III
Optics
GL Glass
PY Polycarbonate
Options
Maximum number of options is six. For more options, please contact your local
American Electric Lighting representative.
Paint
(blank)
BZ
Black (standard)
Bronze
Starter1
EC Encapsulated Plug-in
OP Open Plug-in
Notes:
1
HPS only
Photocontrol
Terminal Block
(blank) None
T2 Wired to L1 & L2 Positions
PC Photocontrol included
T3 3 Wire Operation (L1, N, L2 Position)
Listing
CS
CSA Certified
Lamp
LC
LD
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Misc.
SS
NL
Stainless Steel Hardware
NEMA Label
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
99
Heritage Poles
Chadsworth Series
Cast Aluminum Posts Extruded Shaft
P R O D U C T
O V E R V I E W
Features:
INSTALLATION The post shall be provided with four, hot-dip
galvanized L-type anchor bolts to be installed on a 10" - 12"
diameter bolt circle. A door shall be provided in the base for
anchorage and wiring access. A grounding screw shall be
provided inside the base opposite the door.
MATERIALS The base shall be heavy wall, copper-free, cast
aluminum produced from certified ASTM 356.1 ingot per ASTM B179-95a or ASTM B26-95. The straight shafts shall be extruded from
aluminum, ASTM 6061 alloy, heat treated to a T6 temper. The
tapered shaft shall be extruded from aluminum, ASTM 6063 alloy,
spun to a tapered shape, then heat treated to a T6 temper. All
hardware shall be tamper-resistant stainless steel. Anchor bolts to
be completely hot-dip galvanized.
Smooth
Fluted
12'-0"
CONSTRUCTION The shaft shall be double welded to the base
casting and shipped as one piece for maximum structural integrity.
The shaft shall be circumferentially welded inside the base casting
at the top of the access door, and externally where the shaft exits
the base. All exposed welds below 8’ shall be ground smooth. All
welding shall be per ANSI/AWS D1.2-90. All welders shall be
certified per Section 5 of ANSI/AWS D1.2-90.
DIMENSIONS The post shall be X’- XX" in height with a 16"
diameter base. The shaft diameter shall be XX". (See page 101.) At
the top of the post, an integral 3" O.D. x 3" tenon with a transitional
donut shall be provided for luminaire mounting.
Tapered
Applications:
Streetscapes
Walkways
Pathways
Parks
100
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Heritage Poles
Chadsworth Series
Cast Aluminum Posts Extruded Shaft
O R D E R I N G
I N F O R M AT I O N
Example: P X C H 1 6 1 2 S 5 A N B K A E L
AEL
Series
Height
PX CH16 Chadsworth
8’
10’
12’
14’
16’1
Shaft Type
S4
S5
F4
F5
T4
T5
Smooth 4"Ø
Smooth 5"Ø
Fluted 4"Ø
Fluted 5"Ø
Tapered 4"-3"Ø
Tapered 5"-3"Ø
Options
Manufacturing Code
_________ Receptacles
_________ Banner Arms
_________ Flagpole Holders
_________ Signage
AEL
Finish2
ANBK
ANDB
ANDG
CM
CS
Black
Bronze
Dark Green
Custom Match
Custom Select
RAL colors
(See Accessories section or contact
your local AEL representative.)
Notes:
1
2
16' height not available for S4, F4, or T4 (any
4"Ø) Shaft Type
For finish specifications and color options,
please contact your local American Electric
Lighting representative
DIMENSIONS
8.49"
7.07"
8.5" Dia.
Opening
Door
Opening
10" Dia.
10" - 12"
Bolt 12"
Circle
2"
Hot Dip Galvanized
L-type Anchor Bolts
(4 per Post)
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
101
Heritage Poles
New Albany Series
Cast Aluminum Posts Extruded Shaft
P R O D U C T
O V E R V I E W
Features:
INSTALLATION The post shall be provided with four, hot-dip
galvanized L-type anchor bolts to be installed on a 12" diameter bolt
circle. A door shall be provided in the base for anchorage and wiring
access. A grounding screw shall be provided inside the base opposite
the door.
MATERIALS The base shall be heavy wall, copper-free, cast aluminum
produced from certified ASTM 356.1 ingot per ASTM B-179-95a or
ASTM B26-95. The straight shafts shall be extruded from aluminum,
ASTM 6061 alloy, heat treated to a T6 temper. The tapered shaft shall
be extruded from aluminum, ASTM 6063 alloy, spun to a tapered shape,
then heat treated to a T6 temper. All hardware shall be tamperresistant stainless steel. Anchor bolts to be completely hot-dip
galvanized.
Smooth
Fluted
12'-0"
CONSTRUCTION The shaft shall be double welded to the base casting
and shipped as one piece for maximum structural integrity. The shaft
shall be circumferentially welded inside the base casting at the top of
the access door, and externally where the shaft exits the base. All
exposed welds below 8’ shall be ground smooth. All welding shall be
per ANSI/AWS D1.2-90. All welders shall be certified per Section 5 of
ANSI/AWS D1.2-90.
DIMENSIONS The post shall be X’- XX" in height with a 17" diameter
base. The shaft diameter shall be XX". (See page 103.) At the top of the
post, an integral 3" O.D. x 3" tenon with a transitional donut shall be
provided for luminaire mounting.
Tapered
Applications:
Streetscapes
Walkways
Pathways
Parks
102
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Heritage Poles
New Albany Series
Cast Aluminum Posts Extruded Shaft
O R D E R I N G
I N F O R M AT I O N
Example: P X N Y 1 7 1 2 S 5 A N B K A E L
AEL
Series
Height
PX NY17 New Albany
8’
10’
12’
14’
16’1
Finish2
Shaft Type
S4
S5
F4
F5
T4
T5
Smooth 4"Ø
Smooth 5"Ø
Fluted 4"Ø
Fluted 5"Ø
Tapered 4"-3"Ø
Tapered 5"-3"Ø
ANBK
ANDB
ANDG
CM
CS
Black
Bronze
Dark Green
Custom Match
Custom Select
RAL colors
Manufacturing Code
Options
_________ Receptacles
_________ Banner Arms
_________ Flagpole Holders
_________ Signage
(See Accessories section or contact
your local AEL representative.)
Notes:
1
2
16' height not available for S4, F4, or T4 (any
4"Ø) Shaft Type
For finish specifications and color options,
please contact your local American Electric
Lighting representative
DIMENSIONS
8.5"
Door
Opening
10" Dia.
Opening
12" Dia. Bolt Circle
2"
Hot Dip Galvanized
L-type Anchor Bolts
(4 per Post)
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
103
Heritage Poles
Statesboro Series
Cast Aluminum Posts Extruded Shaft
P R O D U C T
O V E R V I E W
12'-0"
Features:
INSTALLATION The post shall be provided with four, hot-dip
galvanized L-type anchor bolts to be installed on a 9.5" diameter bolt
circle. A door shall be provided in the base for anchorage and wiring
access. A grounding screw shall be provided inside the base
opposite the door.
MATERIALS The base shall be heavy wall, copper free, cast
aluminum produced from certified ASTM 356.1 ingot per ASTM B179-95a or ASTM B26-95. The straight shafts shall be extruded from
aluminum, ASTM 6061 alloy, heat treated to a T6 temper. The tapered
shaft shall be extruded from aluminum, ASTM 6063 alloy, spun to a
tapered shape, then heat treated to a T6 temper. All hardware shall
be tamper-resistant stainless steel. Anchor bolts to be completely
hot-dip galvanized.
Smooth
Fluted
Applications:
Streetscapes
Walkways
Tapered
CONSTRUCTION The shaft shall be double welded to the base
casting and shipped as one piece for maximum structural integrity.
The shaft shall be circumferentially welded inside the base casting
at the top of the access door, and externally where the shaft exits
the base. All exposed welds below 8’ shall be ground smooth. All
welding shall be per ANSI/AWS D1.2-90. All welders shall be
certified per Section 5 of ANSI/AWS D1.2-90.
DIMENSIONS The post shall be X’- XX" in height with a 9" diameter
base. The shaft diameter shall be XX". (See page105.) At the top of
the post, an integral 3" O.D. x 3" tenon with a transitional donut shall
be provided for luminaire mounting.
Pathways
Parks
DIMENSIONS
104
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Heritage Poles
Statesboro Series
Cast Aluminum Posts Extruded Shaft
O R D E R I N G
I N F O R M AT I O N
Example: P X S 9 1 2 S 4 A N B K A E L
AEL
Series
Height
PX S9 Statesboro
8’
10’
12’
14’
S4 Smooth 4"Ø
F4 Fluted 4"Ø
T4 Tapered 4"-3"Ø
ANBK
ANDB
ANDG
CM
CS
Manufacturing Code
Options
Finish2
Shaft Type
Black
Bronze
Dark Green
Custom Match
Custom Select
RAL colors
_________ Receptacles
_________ Banner Arms
_________ Flagpole Holders
_________ Signage
(See Accessories section or contact
your local AEL representative.)
Set Screws
Door
Opening
8" Sq.
Base Plate
6.72"
9.5" Dia.
Bolt Circle
9" Sq.
Base Cover
7"
2"
Hot Dip Galvanized
L-type Anchor Bolts
(4 per Post)
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
105
Heritage Poles
Waycross Series
Cast Aluminum Posts Extruded Shaft
P R O D U C T
O V E R V I E W
Features:
INSTALLATION The post shall be provided with four, hot-dip
galvanized L-type anchor bolts to be installed on 12" diameter bolt
circle. A door shall be provided in the base for anchorage and wiring
access. A grounding screw shall be provided inside the base opposite
the door.
MATERIALS The base shall be heavy wall, copper-free, cast aluminum
produced from certified ASTM 356.1 ingot per
ASTM B-179-95a or ASTM B26-95. The straight shafts shall be
extruded from aluminum, ASTM 6061 alloy, heat treated to a T6 temper.
The tapered shaft shall be extruded from aluminum, ASTM 6063 alloy,
spun to a tapered shape, then heat treated to a T6 temper. All
hardware shall be tamper-resistant stainless steel. Anchor bolts to be
completely hot-dip galvanized.
Smooth
Fluted
12'-0"
CONSTRUCTION The shaft shall be double welded to the base casting
and shipped as one piece for maximum structural integrity. The shaft
shall be circumferentially welded inside the base casting at the top of
the access door, and externally where the shaft exits the base. All
exposed welds below 8’ shall be ground smooth. All welding shall be
per ANSI/AWS D1.2-90. All welders shall be certified per Section 5 of
ANSI/AWS D1.2-90.
DIMENSIONS The post shall be X’- XX" in height with a 17" diameter
base. The shaft diameter shall be XX". (See page 107.) At the top of the
post, an integral 3" O.D. x 3" tenon with a transitional donut shall be
provided for luminaire mounting.
Tapered
Applications:
Streetscapes
Walkways
Pathways
Parks
106
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Heritage Poles
Waycross Series
Cast Aluminum Posts Extruded Shaft
O R D E R I N G
I N F O R M AT I O N
Example: P X W 1 7 1 2 S 5 A N B K A E L
AEL
Series
PX W17 Waycross
8’
10’
12’
14’
16’1
S4
S5
F4
F5
T4
T5
Smooth 4"Ø
Smooth 5"Ø
Fluted 4"Ø
Fluted 5"Ø
Tapered 4"-3"Ø
Tapered 5"-3"Ø
Options
Manufacturing Code
_________ Receptacles
_________ Banner Arms
_________ Flagpole Holders
_________ Signage
AEL
Finish2
Shaft Type
Height
ANBK
ANDB
ANDG
CM
CS
Black
Bronze
Dark Green
Custom Match
Custom Select
RAL colors
(See Accessories section or contact
your local AEL representative.)
Notes:
1
2
16' height not available for S4, F4, or T4 (any
4"Ø) Shaft Type
For finish specifications and color options,
please contact your local American Electric
Lighting representative
DIMENSIONS
8.5"
10" Dia.
Opening
Door
Opening
12" Dia. Bolt Circle
2"
Hot Dip Galvanized
L-type Anchor Bolts
(4 per Post)
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
107
Heritage Series
Weatherproof Receptacles
External, Post Shaft Location
P R O D U C T
O V E R V I E W
Features:
INSTALLATION External receptacles typically are installed above pedestrian level for special event uses and decorative seasonal lighting.
CONSTRUCTION External receptacles typically are installed above pedestrian level for special event uses and decorative seasonal lighting.
Ground Fault Circuit Interrupter Receptacles. Test/Reset buttons on face of receptacles. All Cast Aluminum Covers. Not Plastic. (Paintable to
match post color). Weatherproof “While-in-Use” covers in two sizes.
Receptacle with Wet Location While Closed Cover
Post Shaft
Catalog part # FG-S
Duplex Receptacle with
Ground Fault Interrupter
3/4"
2 7/8"
4 1/2"
SPECIFICATIONS A 20 amp, 125 volt, ground fault circuit
interrupter duplex receptacle shall be mounted in the post.
The receptacle shall be UL Listed according to E-48380 and
UL 943 Class A and UL 498. The receptacle shall have a cast
aluminum, UL Listed cover that is suitable for wet locations
while not in use. The receptacle and cover shall mount to an
outlet opening, in the post shaft, with a gasket and stainless
steel screws.
Wet Location when
closed Cover
Receptacle with Small, In-Use Wet Location Cover
Duplex
Receptacle
with Ground
Fault Interrupter
Catalog part # FGIUS-S
3 3/8"
2 3/8"
Small, Wet
Location while
in use Cover
(for use with
two 3/8" max.
dia. cords)
LIFT OPEN
5 3/4"
SPECIFICATIONS A 20 amp, 125 volt, ground fault circuit
interrupter duplex receptacle shall be mounted in the post.
The receptacle shall be UL Listed according to E-48380 and
UL 943 Class A and UL 498. The receptacle shall have a cast
aluminum, lockable, UL Listed cover that is suitable for wet
locations while in use and complies with NEC Article 41057(b). The cover shall accept most common cord sets up to
3/8” diameter (14/3). The receptacle and cover shall mount to
an outlet opening, in the post shaft, with a gasket and
stainless steel screws.
Receptacle with Large, In-Use Wet Location Cover
Catalog part # FGIUL-S
Duplex
Receptacle
with Ground
Fault Interrupter
3 3/8"
3 3/8"
Large, Wet
Location while
in use Cover
(for use with
two 1/2" max.
dia. cords)
108
Product Guide
LIFT OPEN
5 3/4"
SPECIFICATIONS A 20 amp, 125 volt, ground fault circuit
interrupter duplex receptacle shall be mounted in the post.
The receptacle shall be UL Listed according to E-48380 and
UL 943 Class A and UL 498. The receptacle shall have a cast
aluminum, lockable, UL Listed cover that is suitable for wet
locations while in use and complies with NEC Article 41057(b). The cover shall accept most common cord sets up to
1/2” diameter (12/3). The receptacle and cover shall mount to
an outlet opening, in the post shaft, with a gasket and
stainless steel screws.
For photometric information, visit our website,
www.americanelectriclighting.com
Heritage Series
Weatherproof Receptacles
External, Post Shaft Location
P R O D U C T
O V E R V I E W
Features:
INSTALLATION Internal receptacles typically are installed for use by authorized personnel for special events and owner maintenance purposes.
CONSTRUCTION Ground fault circuit interrupter receptacles. Test and reset buttons on face of receptacles. All cast aluminum covers,
not plastic.
Duplex Receptacle with
Ground Fault Interrupter
Weatherproof Box
Weatherproof Cover
Receptacle with Weatherproof Box and Cover
Catalog part # RB/GFI/WPC
SPECIFICATIONS A 20amp, 125 volt, ground fault circuit interrupter duplex receptacle shall be mounted inside the post base, facing toward the
access door. The receptacle shall be UL Listed according to E-48380 and UL 943 Class A and UL 498. The receptacle shall be mounted in a cast
aluminum box and cover that is suitable for wet locations while not in use. The receptacle and cover shall mount to an outlet box with a gasket
and stainless steel screws.
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
109
Heritage Series
Banner Arms
Cast Aluminum
P R O D U C T
O V E R V I E W
Features:
Removable Standard Half Sphere Cap (H)
Standard 1" Pipe Arm
(1.32" O.D.)
1-1/2" Pipe Arm
(1.9" O.D.)
24"
or required length
BA24H/1/BO
(banner arm, 24”lg., 1.0, with bolt-on
mounting)
BA24H/1.5/BO
(banner arm, 24”lg., 1.5, with bolt-on
mounting)
Other Size Banner Arms Available:
BAXXH/.75
BAXXH/1.25
[banner arm, XX” lg., 3/4” pipe (1.05”O.D) ]
[banner arm, XX” lg., 1-1/4” pipe(1.66”O.D.)]
Other Mounting Options
BA24H/1/CO
(banner arm, with clamp-on
mounting)
EB/BO
(eyebolt mounted to post for
securing banner bottom)
EB/CO
(eyebolt with clamp on
mounted for securing
banner bottom)
BAXXB
(ball end cap)
BAXXA
(acorn end cap)
BBA24H/1/BO
(break-away banner arm)
BAXXR
(raleigh end cap)
110
Product Guide
MATERIALS The end caps shall be,
copper-free, cast aluminum produced from
certified ASTM 356.1 ingot per ASTM B179-95a or ASTM B26-95. The banner arm,
mounting plate and post clamp shall be
aluminum, ASTM 6061 alloy, heat treated to
a T6 temper. All hardware shall be
stainless steel.
CONSTRUCTION The banner arm shall be
welded to a mounting plate or a post
clamp. All welding shall be per ANSI/AWS
D1.2-90. All welders shall be certified per
ANSI/AWS D1.2-90 Section 5.
DIMENSIONS The banner arms shall be
available in 1.05”, 1.32”, 1.66” or 1.9” O.D.
and at the specified length.
Applications:
Other Options
BA24H/1/BO/2EB
(two eyebolts on arm)
INSTALLATION The bolt-on banner arm
shall bolt to a mounting channel provided
on the side of the post with four stainless
steel screws. Eyebolts shall screw in to the
post or clamp-on. All clamp-on mountings
shall clamp around the post, secured with
four 3/8” hex head bolts. (Post dia. at
mounting point must be specified.) A
minimum mounting height of 10 feet is
recommended for the bottom banner arm.
(Arms are not designed for pedestrian
interference.) For information on specifying
orientation and mounting heights, see
Orientation Guide, page 130.
BA24H/1/BO/S/2EB
(decorative scroll and two eyebolts
on arm)
For photometric information, please visit our website,
www.americanelectriclighting.com
Streetscapes
Walkways
Pathways
Parks
Heritage Series
Banner Arms
Cast Aluminum
O R D E R I N G
I N F O R M AT I O N
Example: B A C 1 9 B A C D 4 1 8 H 4 B A E B E B C 1 9 E B C D 4 A N B K A E L
AEL
Length/End Cap/ Arm Dia.
12
H Half Sphere
18
B Ball Cap
19
A Acorn Cap
20
R Raleigh Cap
24
Arm Dia.
25
26
3 3/4”O
28
4 1”O
30
5 1-1/4”O
36
6 1-1/2”O
Banner Arms1,2
BAB
2BAB
3BAB
4BAB
6BAB
8BAB
One Set
BAC19
BAC28
BAC29
BAC39
BAC49
One
Two
Three
Four
Six
Eight
Two Sets
One
2BAC19
Two @ 180 2BAC28
Two @ 90 2BAC29
Three @ 90 2BAC39
Four @ 90 2BAC49
Options
BBA Breakaway Arm
BAEB Arm w/eyebolts
BAEBS Arm w/eyebolts and
scroll
Eyebolts (type, qty)
EBB
2EBB
3EBB
4EBB
One Set
EBC19
EBC28
EBC29
EBC32
EBC39
EBC49
BA Clamp Dia.2,3
BACD3
BACD3-1/2
BACD4
BACD4-1/2
BACD5
BACD5-1/2
BACD6
BACD6-1/2
BACD7
BACD7-1/2
BACDTBS
3”O
3-1/2”O
4”O
4-1/2”O
5”O
5-1/2”O
6”O
6-1/2”O
7”O
7-1/2”O
0 to be specified
One
Two
Three
Four
Two Sets
One
2EBC19
Two @ 180 2EBC28
Two @ 90 2EBC29
Three @120 2EBC32
Three @ 90 2EBC39
Four @ 90 2EBC49
Manufacturing Code
3”O
3-1/2”O
4”O
4-1/2”O
5”O
5-1/2”O
6”O
6-1/2”O
7”O
7-1/2”O
0 to be
specified
AEL
Finish4
ANBK
ANDB
ANDG
ANVG
ANPP
CM
CS
Black
Dark Bronze
Dark Green
Verde Green
Prime Painted
Custom Match
Custom Select
RAL colors
1 For information on specifying orientation and mounting heights, see
Orientation Guide, page 130
2 A minimum mounting height of 10' is recommended for the bottom banner arm
3 For clamp dia., take post dia. and round up to the nearest 1/2"
4 For finish and color options, please contact your local AEL representative
XX"
Clamp with (4) 3/8" Hex Hd.
Bolts to Clamp On Post
(4) Stainless Steel Screws to Post
BAB XXH4
xx"
Clamp-On Mounting
BAC19 BACDxx XXH4
2BBA26H/1/BO*
(2 Break-away Banner Arms, 26”, Half
sphere and cap/1”0/Bolt-on)
SUGGESTED BANNER ARM USAGE
EBCD3
EBCD3-1/2
EBCD4
EBCD4-1/2
EBCD5
EBCD5-1/2
EBCD6
EBCD6-1/2
EBCD7
EBCD7-1/2
EBCDTBS
Notes:
XX"
Bolt-On Mounting
EB Clamp Dia. 2,3
30"
28" wide banner
Note:
* For arms for
two banners
with bolt on
option add 2
before the arm
and eyebolt
part no.
BA18R/1.25/CO2(180)5
(Banner Arms, 18”, Raleigh end cap/1.25”0/ ClampOn, 2 arms at 180 degrees, 5” 0 post shaft)
26"
18"
24" wide banner
16" wide
banner
Note:
* For arms for
two banners
with bolt on
option add 4
before the arm
part no.
EBB*
(EyeBolt, Bolt-on)
Notes:
* For information on
specifying orientation and
mounting heights, see
Orientation Guide on page
130. A minimum mounting
height of 10’ is
recommended for the
bottom banner arm.
• Banners not furnished by
American Electric Lighting.
EB/CO2(180)5
(EyeBolt /Clamp-On, 2 at 180 degrees, 5”0 post shaft
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
111
Heritage Series
Flagpole Holders
Cast Aluminum
P R O D U C T
O V E R V I E W
1" Flagpole
Features:
3/4" Flagpole
FPH3B
FPH4B
(holder for 1" pole
with bolt-on mounting)
1-1/4" Flagpole
(holder for 3/4" pole
with bolt-on mounting)
1-1/2" Flagpole
MATERIALS The flagpole holders shall be
aluminum, ASTM 6061 alloy, heat treated
to a T6 temper. All hardware shall be
stainless steel.
FPH6B
FPH5B
(holder for 1-1/4" pole
with bolt-on mounting)
INSTALLATION The flagpole holders shall
bolt to a mounting channel on the side of
the post with four stainless steel screws.
The clamp-on mounting shall clamp
around the post, secured with four 3/8”
hex head bolts. (Post diameter at
mounting point must be specified.)
Holders are available for 3/4”, 1”, 1-1/4”,
and 1-1/2” O.D. flag poles. For information
on specifying orientation and mounting
heights see Orientation Guide, page 130.
(Flags and flag poles provided by others.)
(holder for 1-1/2" pole
with bolt-on mounting)
CONSTRUCTION The flagpole holders
shall be one-piece construction. The
holders shall consist of a piece of
aluminum tubing welded at 45° to a
mounting plate. All welding shall be per
ANSI/AWS D1.2-90. All welders shall be
certified per ANSI/AWS D1.2-90 Section 5.
Other Mounting Options
Applications:
1" Flagpole
Streetscapes
Walkways
Pathways
Parks
3/4" Flagpole
FPH4C19
(holder for 1" pole
with clamp-on mounting)
1-1/4" Flagpole
FPH3C19
(holder for 3/4" pole
with clamp-on mounting)
1-1/2" Flagpole
FPH5C19
(holder for 1-1/4" pole
with clamp-on mounting)
FPH6C19
(holder for 1-1/2" pole
with clamp-on mounting)
Notes:
Flags can add substantial wind loading to the post you select.
Please coordinate the correct post size and style with the factory.
112
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage Series
Flagpole Holders
Cast Aluminum
O R D E R I N G
I N F O R M AT I O N
Example F P H 4 C 1 9
FPHCD4 ANBK AEL
AEL
Flagpole Holders
Bolt-on1
1”0
1-1/4”0 1-1/2”0
3/4”0
FPH3B
FPH4B FPH5B
FPH6B
2FPH3B 2FPH4B 2FPH5B 2FPH6B
3FPH3B 3FPH4B
FPH5B 3FPH6B
4FPH3B 3FPH4B 3FPH5B 3FPH6B
3/4”0
FPH3C19
2FPH3C28
3FPH3C29
4FPH3C39
FPH3C49
Notes:
1
2
3
1 holder
2 holders
3 holders
4 holders
Clamp-on
1”0
1-1/4”0
1-1/2”0
FPH4C19 FPH5C19
FPH6C19
2FPH4C28 2FPH5C28 2FPH6C28
3FPH4C29 3FPH5C29 3FPH6C29
4FPH4C39 4FPH5C39 4FPH6C39
FPH4C49 FPH5C49
FPH6C49
1 holder
2 holders @ 180
2 holders @ 90
3 holders @ 90
4 holders @ 90
FPH Clamp Dia. 2,3
(clamp-ons only)
FPHCD3 3”0
FPHCD3-1/2
3-1/2”0
FPHCD4 4”0
FPHCD4-1/2
4-1/2”O
FPHCD5 5”0
FPHCD5-1/2
5-1/2”0
FPHCD6 6”0
FPHCD6-1/2
6-1/2”0
FPHCD7 7”0
FPHCD7-1/2
7-1/2”O
FPHCDTBS0 to be specified
Manufacturing Code
Finish3
ANBK
ANDB
ANDG
ANVG
ANPP
CM
CS
AEL
Black
Dark Bronze
Dark Green
Verde Green
Prime Painted
Custom Match
Custom Select
RAL colors
For information on specifying orientation and mounting heights, see Orientation Guide, page 130
For clamp dia., take post dia. and round up to the nearest 1/2"
For finish and color options see, please contact your local AEL representative
FPH3C29
Clamp-On Mounting
Post Top Mounting
Clamp with (4) 3/8" Hex Hd.
Bolts to Clamp On Post
(4) 1/4" Button Hd. Socket
Screws to Post
FPH4C19 FPHCDxx
FPH4B
Suggested Flagpole Usage
orientation
orientation
FPH4B
Flagpole holder, for 1”0 pole,
bolt-on
FPH4C28 FPHCD5
Flagpole holder, for
1”0, clamp-on with
2 holders at 180
degrees, clamp for
5”0 post.
Notes: For holders for two (or more)
poles with bolt-on mounting, add 2 or
required number before the part
number.
orientation
FPH4C29 FPHCD5
(Flagpole holder, for 1”0 pole, clamp-on with 2
holders at 90-degrees, clamp for a 5”0 post)
orientation
FPH4C29 FPHCD5
(Flagpole holder, for 1”0 pole,
clamp-on with 4 holders at 90degrees, clamp for a 5”0 post)
orientation
Notes:
* For information on specifying
orientation and mounting heights,
see Orientation Guide, page 130
• Flags not furnished by American
Electric Lighting
See pages 259-264 for a complete listing
of Frequently Ordered Products
FPH4C39 FPHCD5
(Flagpole holder, for 1”0 pole, clamp-on with 3
holders at 90 degrees, clamp for a 5”0 post)
Product Guide
113
Heritage Series
Street Signs
Cast Aluminum Octagonal Frames
P R O D U C T
O V E R V I E W
5"
20"
3" x 18" Solid Sign Opening
6" x 35 1/2" Solid Sign Opening
8"
37.5"
37.5"
(single sign frame
w/ bolt-on mounting)
(double sign frame
w/ bolt-on mounting)
SS1OB
SS2OB
Other Mounting Options
(with post top mounting)
(with clamp-on mounting)
SS1OP
SS1OC19 SSCDxx
Features:
INSTALLATION The bolt-on sign frame shall
bolt to a mounting channel on the side of the
post with four stainless steel screws. The
clamp-on mounting shall clamp around the
post, secured with four 3/8" hex head bolts.
(Post dia. at mounting point must be specified.)
The post top mounting shall fit on a 3" O.D. x 3"
tall tenon with six 1/4" dia. socket set screws.
(Lettering and graphics provided by others.)
For information on specifying orientation and
mounting heights, see Orientation Guide,
page 130.
MATERIALS The sign frame shall be heavy
wall, copper free, cast aluminum produced
from certified ASTM 356.1 ingot per ASTM B179-95a or ASTM B26-95. The mounting plate,
post clamp, post top fitter, and banner arm
shall be aluminum, ASTM 6061, heat treated to
a T6 temper. All hardware shall be stainless
steel.
CONSTRUCTION The street sign frame shall be
welded to a mounting plate, post clamp, or
post top fitter. All welding shall be per ANSI/
AWS D1.2-90. All welders shall be certified per
ANSI/AWS D1.2-90 Section 5.
(hanging from banner arm
with bolt-on mounting)
(hanging from banner arm
with clamp-on mounting)
SS1OC19 SSCDxx SWBA
SS1OB SWBA
Decorative Options
(Note: All decorative and
mounting options available
with single or double signs)
DIMENSIONS Sign frame shall measure 37.5"
wide and 8" tall with a 6" x 35.5" opening for
graphics mounting. The optional smaller frame
shall measure 20" wide and 5" tall with a 3" x
18" opening for graphics mounting.
DESCRIPTION The street sign frame shall be a
curved shaped, one-piece casting with a solid
backing and a 1" thick border. The sign frame
has an optional smaller top casting typically
used for cross street name. The sign frame is
identical on both sides.
SS1OPAF
(decorative finial)
SS2OB SWS
(decorative scroll)
114
Product Guide
SS2OB SWBAS
(decorative scroll on banner arm)
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage Series
Street Signs
Cast Aluminum Octagonal Frames
O R D E R I N G
I N F O R M AT I O N
Example: S S 1 O C 1 9 S S C D 4 S W B A A N B K A E L
AEL
Options
SS Clamp Dia.2
Manufacturing Code
(clamp-on
only)
(bolt-on & clamp- on only)
Post Top
SSCD3 3”O
AEL
SWS Sign w/ Scroll
SS1OB Single Frame
SS1OP Single Frame
SSCD3-1/2 3-1/2”O
SWBA Sign w/ Banner Arm
SS2OB Double Frame
SS2OP Double Frame
SSCD4 4”O
SWBAS Sign w/ Banner Arm
2SS1OB 2 Single Frames
SS1OP29 2 Single Frames
SSCD4-1/2 4-1/2”O
and Scroll
2SS2OB 2 Double Frames
@ 90
SSCD5 5”O
SS1OPAF Single Frame
SSCD5-1/2 5-1/2”O
Finish
Clamp-Ons
w/Finial
SSCD6 6”O
SS1OC19 Single Frame
SS2OPAF Double Frame
ANBK Black
SSCD6-1/2 6-1/2”O
SS2OC19 Double Frame
w/Finial
ANDB Dark Bronze
SSCD7 7”O
SS1OC29 2 Single Frames @ 90 SS1OP29AF 2 Single Frames
ANDG Dark Green
SSCD7-1/2
7-1/2”O
SS2OC29 2 Double Frames @ 90
@ 90 w/Finial
ANVG Verde Green
SSCDTBS 0 to be specified
Notes:
ANPP Prime Painted
CM Custom Match
1 For information on specifying orientation and mounting heights see the Orientation Guide.
CS Custom Select
2 For clamp dia, take post dia. and round up to the nearest 1/2".
RAL colors
Curved Street Sign Frames
Bolt-Ons1
Bolt-On Mounting
Clamp-On Mounting
Clamp with (4) 3/8" Hex Hd. Bolts to Clamp On Post
(4) Stainless Steel Screws to
Post
xx"
SS1OC19 SSCDxx
SS1OB
Hanging with Bolt-On or Clamp-On Mounting
Post Top Mounting
(6) 1/4" Socket Set Screws
(4) Stainless Steel Screws to Post
(Also available with Clamp-On Mounting,
see above and front page)
Banner Arm
(6) 1/4" Socket Set Screws
Slip Fits 3" O.D. x 3" High Tenon
SS1OB SWBA (Bolt-on)
SS1OC19 SSCDxx SWBA (Clamp-on)
SS1OP
For Twin Signs (with Bolt-On mounting only) a 2 is added before the part no. (ie: 2SS1CB)
Post Top Mounting
Clamp-On Mounting
Signs
90¡
90¡
Signs
Post
Post
SS1OC29 SSCDxx
SS1OP29
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
115
Heritage Series
Street Signs
Cast Aluminum Oval Frames
P R O D U C T
O V E R V I E W
5"
20"
3" x 18" Solid Sign Opening
6" x 35 1/2" Solid Sign Opening
8"
37.5"
37.5"
SS1B
SS2B
(single sign frame
w/ bolt-on mounting)
(double sign frame
w/ bolt-on mounting)
Other Mounting Options
SS1P
SS1C19 SSCDxx
(with post top mounting )
(with clamp-on mounting)
Features:
INSTALLATION The bolt-on sign
frame shall bolt to a mounting channel
on the side of the post with four
stainless steel screws. The clamp-on
mounting shall clamp around the post,
secured with four 3/8" hex head bolts.
(Post dia. at mounting point must be
specified.) The post top mounting
shall fit on a 3" O.D. x 3" tall tenon with
six 1/4" dia. socket set screws.
(Lettering and graphics provided by
others.) For information on specifying
orientation and mounting heights, see
Orientation Guide, page 130.
MATERIALS The sign frame shall be
heavy wall, copper-free, cast
aluminum produced from certified
ASTM 356.1 ingot per ASTM B-17995a or ASTM B26-95. The mounting
plate, post clamp, post top fitter and
banner arm shall be aluminum, ASTM
6061, heat treated to a T6 temper. All
hardware shall be stainless steel.
CONSTRUCTION The street sign
frame shall be welded to a mounting
plate, post clamp or post top fitter. All
welding shall be per ANSI/ AWS D1.290. All welders shall be certified per
ANSI/AWS D1.2-90 Section 5.
SS1C19 SSCDxx SWBA
SS1B SWBA
(hanging from banner arm
with bolt-on mounting)
(hanging from banner arm
with clamp-on mounting)
Decorative Options
(Note: All decorative and
mounting options available
with single or double signs)
SS1PAF
(decorative finial)
SS2B SWS
(decorative scro ll)
116
Product Guide
SS2B SWBAS
(decorative scroll on banner arm)
For photometric information, please visit our website,
www.americanelectriclighting.com
DIMENSIONS Sign frame shall
measure 37.5" wide and 8" tall with a
6" x 35.5" opening for graphics
mounting. The optional smaller frame
shall measure 20" wide and 5" tall with
a 3" x 18" opening for graphics
mounting.
DESCRIPTION The street sign frame
shall be a curve shaped, one-piece
casting with a solid backing and a 1"
thick border. The sign frame has an
optional smaller top casting typically
used for cross street name. The sign
frame is identical on both sides.
Heritage Series
Street Signs
Cast Aluminum Oval Frames
O R D E R I N G
I N F O R M AT I O N
Example: S S 1 C 1 9 S S C D 4 S W B A A N B K A E L
AEL
Options
SS Clamp Dia.2
Curved Street Sign Frames
(clamp-on only)
(bolt-on & clamp- on only)
SSCD3 3”O
SWS Sign w/Scroll
SS1B Single Frame
Single Frame
SSCD3-1/2 3-1/2”O
SWBA Sign w/Banner Arm
SS2B Double Frame
Double Frame
SSCD4 4”O
SWBAS Sign w/Banner Arm
2SS1B 2 Single Frames
2 Single Frames
SSCD4-1/2 4-1/2”O
and Scroll
2SS2B 2 Double Frames
@ 90
SSCD5 5”O
SS1PAF Single Frame
SSCD5-1/2 5-1/2”O
Clamp-Ons
w/ Finial
ANBK
SSCD6 6”O
SS1C19 Single Frame
SS2PAF Double Frame
ANDB
SSCD6-1/2 6-1/2”O
SS2C19 Double Frame
w/ Finial
ANDG
SSCD7 7”O
SS1C29 2 Single Frames @ 90 SS1P29AF 2 Single Frames
ANVG
SSCD7-1/2 7-1/2”O
SS2C29 2 Double Frames @ 90
@ 90 w/ Finial
ANPP
SSCDTBS 0 to be specified
Notes:
CM
1 For information on specifying orientation and mounting heights see Orientation Guide, page 130
CS
2 For clamp dia., take post dia. and round up to the nearest 1/2"
Bolt-Ons1
Manufacturing Code
Post Top
SS1P
SS2P
SS1P29
Bolt-On Mounting
AEL
Finish
Black
Dark Bronze
Dark Green
Verde Green
Prime Painted
Custom Match
Custom Select
RAL colors
Clamp-On Mounting
Clamp with (4) 3/8" Hex Hd. Bolts to Clamp On Post
(4) Stainless Steel Screws to
Post
xx"
SS1C19 SSCDxx
SS1B
Hanging with Bolt-On or Clamp-On Mounting
Post Top Mounting
(6) 1/4" Socket Set Screws
(4) Stainless Steel Screws to Post
(Also available with Clamp-On Mounting,
see above and front page)
Banner Arm
(6) 1/4" Socket Set Screws
Slip Fits 3" O.D. x 3" High Tenon
SS1B SWBA (Bolt-On)
SS1C19 SSCDxx SWBA (Clamp-On)
SS1P
For Twin Signs (with Bolt-On mounting only) a 2 is added before the part no. (ie: 2SS1CB)
Post Top Mounting
Clamp-On Mounting
Signs
90¡
90¡
Signs
Post
Post
SS1C29 SSCDxx
SS1P29
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
117
Heritage Series
Street Signs
Cast Aluminum Rectangular Frames
P R O D U C T
O V E R V I E W
5"
20"
3" x 18" Solid Sign Opening
6" x 35 1/2" Solid Sign Opening
8"
37.5"
37.5"
(single sign frame
w/ bolt-on mounting)
(double sign frame
w/ bolt-on mounting)
SS2RB
SS1RB
Features:
INSTALLATION The bolt-on sign frame shall bolt
to a mounting channel on the side of the post
with four stainless steel screws. The clamp-on
mounting shall clamp around the post, secured
with four 3/8" hex head bolts. (Post dia. at
mounting point must be specified.) The post top
mounting shall fit on a 3" O.D. x 3" tall tenon with
six 1/4" dia. socket set screws. (Lettering and
graphics provided by others) For information on
specifying orientation and mounting heights, see
Orientation Guide, page 130.
MATERIALS The sign frame shall be heavy wall,
copper-free, cast aluminum produced from
certified ASTM 356.1 ingot per ASTM B-179-95a
or ASTM B26-95. The mounting plate, post
clamp, post top fitter and banner arm shall be
aluminum, ASTM 6061, heat treated to a T6
temper. All hardware shall be stainless steel.
Other Mounting Options
(with post top mounting)
(with clamp-on mounting)
SS1RC19 SSCDxx
SS1RP
CONSTRUCTION The street sign frame shall be
welded to a mounting plate, post clamp or post
top fitter. All welding shall be per ANSI/ AWS
D1.2-90. All welders shall be certified per
ANSI/AWS D1.2-90 Section 5.
DIMENSIONS Sign frame shall measure 37.5"
wide and 8" tall with a 6" x 35.5" opening for
graphics mounting. The optional smaller frame
shall measure 20" wide and 5" tall with a 3" x 18"
opening for graphics mounting.
(hanging from banner arm
with bolt-on mounting)
(hanging from banner arm
with clamp-on mounting)
SS1RB SWBA
SS1RC19 SSCDxx SWBA
Decorative Options
(Note: All decorative and
mounting options available
with single or double signs)
DESCRIPTION The street sign frame shall be a
curve shaped, one-piece casting with a solid
backing and a 1" thick border. The sign frame has
an optional smaller top casting typically used for
cross street name. The sign frame is identical on
both sides.
(decorative finial)
SS1RPAF
SS2RB SWS
118
Product Guide
SS2RB SWBAS
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage Series
Street Signs
Cast Aluminum Rectangular Frames
O R D E R I N G
I N F O R M AT I O N
Example: S S 1 R C 1 9 S S C D 4 S W B A A N B K A E L
AEL
SS Clamp Dia.2
Options
Manufacturing Code
(clamp-on
only)
(bolt-on
&
clamp- on only)
Post Top
SSCD3 3”O
AEL
SWS Sign w/ Scroll
SS1RB Single Frame
SSR1P Single Frame
SSCD3-1/2 3-1/2”O
SWBA Sign w/ Banner Arm
SS2RB Double Frame
SSR2P Double Frame
SSCD4 4”O
SWBAS Sign w/ Banner Arm
2SS1RB 2 Single Frames
SS1RP29 2 Single Frames
SSCD4-1/2 4-1/2”O
and Scroll
2SS2RB 2 Double Frames
@ 90
SSCD5 5”O
SS1RPAF Single Frame
Finish
SSCD5-1/2 5-1/2”O
Clamp-Ons
w/ Finial
ANBK
Black
SSCD6 6”O
SS1RC19 Single Frame
SS2RPAF Double Frame
ANDB Dark Bronze
SSCD6-1/2 6-1/2”O
SS2RC19 Double Frame
w/ Finial
ANDG Dark Green
SSCD7 7”O
SS1RC29 2 Single Frames @ 90 SS1RP29AF 2 Single Frames@
ANVG Verde Green
SSCD7-1/2
7-1/2”O
SS2RC29 2 Double Frames @ 90
90 w/ Finial
ANPP Prime Painted
SSCDTBS 0 to be specified
Notes:
CM Custom Match
CS Custom Select
1 For information on specifying orientation and mounting heights see Orientation Guide, page 130
RAL colors
2 For clamp dia., take post dia. and round up to the nearest 1/2"
Curved Street Sign Frames
Bolt-Ons1
Bolt-On Mounting
Clamp-On Mounting
Clamp with (4) 3/8" Hex Hd. Bolts to Clamp On Post
(4) Stainless Steel Screws to Post
xx"
SS1RB
SS1RC19 SSCDxx
Hanging with Bolt-On or Clamp-On Mounting
Post Top Mounting
(6) 1/4" Socket Set Screws
(4) Stainless Steel Screws to Post
(Also available with Clamp-On Mounting,
see above and front page)
Banner Arm
(6) 1/4" Socket Set Screws
Slip Fits 3" O.D. x 3" High Tenon
SS1RP
SS1RB SWBA (Bolt-on)
SS1RC19 SSCDxx SWBA (Clamp-on)
For Twin Signs (with Bolt-On mounting only) a 2 is added before the part no. (ie: 2SS1CB)
Post Top Mounting
Clamp-On Mounting
SS1RC29 SSCDxx
SS1RP29
Signs
90¡
90¡
Signs
Post
See pages 259-264 for a complete listing
of Frequently Ordered Products
Post
Product Guide
119
Heritage Series
Street Signs
Cast Aluminum Curved Frames
P R O D U C T
O V E R V I E W
Features:
5"
20"
3" x 18" Solid Sign Opening
6" x 35 1/2" Solid Sign Opening
8"
37.5"
37.5"
(single sign frame
w/ bolt-on mounting)
(double sign frame
w/ bolt-on mounting)
SS1CB
SS2CB
MATERIALS The sign frame shall be heavy
wall, copper-free, cast aluminum produced
from certified ASTM 356.1 ingot per ASTM B179-95a or ASTM B26-95. The mounting
plate, post clamp, post top fitter and banner
arm shall be aluminum, ASTM 6061, heat
treated to a T6 temper. All hardware shall be
stainless steel.
Other Mounting Options
(with post top mounting )
SS1CP
(with clamp-on mounting)
SS1CC19 SSCDxx
(hanging from banner arm
with bolt-on mounting)
(hanging from banner arm
with clamp-on mounting)
SS1CB SWBA
SS1CC19 SSCDxx SWBA
Decorative Options
(Note: All decorative and
mounting options available
with single or double signs)
(decorative finial)
SS1CPAF
(decorative scro ll)
SS2CB SWS
120
Product Guide
INSTALLATION The bolt-on sign frame shall
bolt to a mounting channel on the side of the
post with four stainless steel screws. The
clamp-on mounting shall clamp around the
post, secured with four 3/8" hex head bolts.
(Post dia. at mounting point must be
specified.) The post top mounting shall fit on
a 3" O.D. x 3"tall tenon with six 1/4" dia.
socket set screws. (Lettering and graphics
provided by others.) For information on
specifying orientation and mounting heights,
see Orientation Guide, page 130.
(decorative scroll on banner arm)
SS2CB SWABS
For photometric information, please visit our website,
www.americanelectriclighting.com
CONSTRUCTION The street sign frame shall
be welded to a mounting plate, post clamp or
post top fitter. All welding shall be per ANSI/
AWS D1.2-90. All welders shall be certified
per ANSI/AWS D1.2-90 Section 5.
DIMENSIONS Sign frame shall measure 37.5"
wide and 8" tall with a 6" x 35.5" opening for
graphics mounting. The optional smaller
frame shall measure 20" wide and 5" tall with
a 3" x 18" opening for graphics mounting.
DESCRIPTION The street sign frame shall be
a curve shaped, one-piece casting with a
solid backing and a 1" thick border. The sign
frame has an optional smaller top casting
typically used for cross street name. The
sign frame is identical on both sides.
Heritage Series
Street Signs
Cast Aluminum Curved Frames
O R D E R I N G
I N F O R M AT I O N
Example: S S 1 C C 1 9 S S C D 4 S W B A A N B K A E L
AEL
Curved Street Sign Frames
Options
Manufacturing Code
(clamp-on only)
(bolt-on & clamp- on only)
SSCD3 3”O
Single Frame
Single Frame
AEL
SWS Sign w/ Scroll
SSCD3-1/2 3-1/2”O
Double Frame
Double Frame
SWBA Sign w/ Banner Arm
SSCD4 4”O
2 Single Frames
2 Single Frames
SWBAS Sign w/ Banner Arm
SSCD4-1/2 4-1/2”O
2 Double Frames
@ 90
and Scroll
SSCD5 5”O
SS1CPAF Single Frame
Finish
SSCD5-1/2 5-1/2”O
Clamp-Ons
w/ Finial
SSCD6 6”O
ANBK Black
SS1CC19 Single Frame
SS2CPAF Double Frame
SSCD6-1/2 6-1/2”O
ANDB Dark Bronze
SS2CC19 Double Frame
w/ Finial
SSCD7 7”O
ANDG Dark Green
SS1CC29 2 Single Frames @ 90 SS1CP29AF 2 Single Frames
SSCD7-1/2 7-1/2”O
ANVG Verde Green
SS2CC29 2 Double Frames @ 90
@ 90 w/ Finial
SSCDTBS 0 to be specified
ANPP Prime Painted
CM Custom Match
Notes:
CS Custom Select
1 For information on specifying orientation and mounting heights see Orientation Guide, page 130
RAL colors
2 For clamp dia, take post dia. and round up to the nearest 1/2"
Bolt-ons1
SS1CB
SS2CB
2SS1CB
2SS2CB
SS Clamp Dia.2
Post Top
SS1CP
SS2CP
SS1CP29
Bolt-On Mounting
Clamp-On Mounting
Clamp with (4) 3/8" Hex Hd. Bolts to Clamp On Post
xx"
(4) Stainless Steel Screws to Post
SS1CC19 SSCDxx
SS1CB
Post Top Mounting
Hanging with Bolt-On or Clamp-On Mounting
(6) 1/4" Socket Set Screws
(4) Stainless Steel Screws to Post
(Also available with Clamp On Mounting,
see above and front page)
Banner Arm
(6) 1/4" Socket Set Screws
Slip Fits 3" O.D. x 3" High Tenon
SS1CP
SS1CB SWBA (Bolt-on)
SS1CC19 SSCDxx SWBA (Clamp-on)
For Twin Signs (with Bolt-On mounting only) a 2 is added before the part no. (ie: 2SS1CB)
Post Top Mounting
Clamp-On Mounting
SS1CP29
Signs
SS1CC29 SSCDxx
90°
90°
Signs
Post
See pages 259-264 for a complete listing
of Frequently Ordered Products
Post
Product Guide
121
Heritage Series
Ladder Rests
Cast Aluminum
P R O D U C T
O V E R V I E W
Features:
1"
INSTALLATION The ladder rest shall mount on a 3” O.D. tenon,
below the luminaire, with four 1/4” diameter socket set screws.
MATERIALS The ladder rests shall be heavy wall, copper-free,
cast aluminum produced from certified ASTM 356.1 ingot per
ASTM B-179-95A or ASTM B26-95. All hardware shall be
stainless steel.
16"
LRD
CONSTRUCTION The ladder rests shall be one-piece cast
aluminum construction. The castings are decorative replicas of
ladder rests used on posts with gas lamps.
1"
DIMENSIONS The ladder rest shall have a 1” tall mounting height
with either a 16” or 17.5”span.
Applications:
17.5"
LRT
Streetscapes
Walkways
Pathways
Parks
3" O.D . Tenon
(4)1 /4 " Socket Set
Screws
post #
luminaire #
LRT
(post and luminaire with ladder rest)
122
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage Series
Medium Post Top Finials
Tenon Cast Aluminum
O R D E R I N G
I N F O R M AT I O N
Features:
INSTALLATION The finials shall mount to a post top tenon
using stainless steel socket set screws.
MATERIALS The finial castings shall be heavy-wall,
copper free, cast aluminum produced from certified ASTM
356.1 ingot per ASTM B-179-95a or ASTM B26-95. The
tubing shall be aluminum, ASTM 6061 alloy, heat treated to
a T6 temper. All hardware shall be stainless steel.
23 "
21 "
6.25 "
5"
CH F
LBF
CONSTRUCTION The finials shall be one-piece
construction. The finials shall consist of a one-piece
casting or a casting welded to a piece of aluminum tubing.
All welding shall be per ANSI/AWS D1.2-90. All welders
shall be certified per ANSI/AWS D1.2-90 Section 5.
Applications:
Streetscapes
Walkways
Pathways
Parks
15"
14.5"
12 "
6.25 "
6.25 "
6.25 "
BF/MT
PF/MT
FF/ MT
Example: B F / M T U A N B K A E L
AEL
Series
22"
21.5"
19"
7"
7"
7"
BF/MTU
PF/MTU
FF/ MTU
CHF
LBF
BF/MT
PF/MT
FF/MT
BF/MTU
PF/MTU
FF/MTU
BF/MTD
PF/MTD
FF/MTD
Finish1
ANBK
ANDB
ANDG
ANVG
ANPP
CM
CS
Black
Dark Bronze
Dark Green
Verde Green
Prime Painted
Custom Match
Custom Select
RAL colors
Manf. Code
AEL
Notes:
1 For finish specifications and color
options, please contact your local
AEL representative
22"
21.5"
19 "
9"
9"
9"
BF/M TD
PF/MTD
FF/ MTD
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
123
Heritage Series
Large Post Top Finials
Tenon Cast Aluminum
P R O D U C T
O V E R V I E W
Features:
18 "
16 "
14 "
INSTALLATION The finials shall mount to a post
top tenon using stainless steel socket set
screws.
7.5"
7.5"
9.25 "
BRF
PRF
FR F
CONSTRUCTION The finials shall be one-piece
construction. The finials shall consist of a onepiece casting or a casting welded to a piece of
aluminum tubing. All welding shall be per
ANSI/AWS D1.2-90. All welders shall be certified
per ANSI/AWS D1.2-90 Section 5.
21"
19.5"
17.5"
MATERIALS The finial castings shall be heavywall, copper-free, cast aluminum produced from
certified ASTM 356.1 ingot per ASTM B-179-95a
or ASTM B26-95. The tubing shall be aluminum,
ASTM 6061 alloy, heat treated to a T6 temper. All
hardware shall be stainless steel.
Applications:
9.75 "
9.75 "
9.75 "
BRF/LT
PRF/ LT
FR F/ LT
Streetscapes
Walkways
Pathways
Parks
Example: B R F / L T U A N B K A E L
AEL
Series
11"
11 "
11 "
BRF/L TU
PRF/ LTU
FR F/LTU
14"
14 "
14"
BRF/L TD
PRF/ LTD
FR F/ LTD
Product Guide
BRF
PRF
FRF
BRF/LT
PRF/LT
FRF/LT
BRF/LTU
PRF/LTU
FRF/LTU
BRF/LTD
PRF/LTD
FRF/LTD
31.5"
30"
28"
124
31.5"
30 "
28 "
For photometric information, please visit our website,
www.americanelectriclighting.com
Finish1
ANBK
ANDB
ANDG
ANVG
ANPP
CM
CS
Black
Dark Bronze
Dark Green
Verde Green
Prime Painted
Custom Match
Custom Select
RAL colors
Manf. Code
AEL
Notes:
1 For finish specifications and color
options, please contact your local
AEL representative
Heritage Series
Small Post Top Finials
Cast Aluminum
P R O D U C T
O V E R V I E W
Features:
12"
7.5"
10"
INSTALLATION The finials shall mount to a post top
tenon using stainless steel socket set screws.
10"
3.5"
3.5"
3.5"
SBF
NAF
ASF
8"
8"
MATERIALS The finial castings shall be heavy-wall,
copper-free, cast aluminum produced from certified
ASTM 356.1 ingot per ASTM B-179-95a or ASTM B2695. The tubing shall be aluminum, ASTM 6061 alloy,
heat treated to a T6 temper. All hardware shall be
stainless steel.
CONSTRUCTION The finials shall be one-piece
construction. The finials shall consist of a one-piece
casting or a casting welded to a piece of aluminum
tubing. All welding shall be per ANSI/AWS D1.2-90. All
welders shall be certified per ANSI/AWS D1.2-90
Section 5.
8"
4"
4.5"
4.5"
4.5"
SC F
MBF
CCF
OMF
Applications:
Streetscapes
Walkways
Pathways
Parks
15 "
12"
11.5 "
Example: W F A N B K A E L
8.5"
4.5"
4.5"
4.5"
4.5"
RWF
TMF
TLF
FMF
12 "
11.5 "
9.5"
9"
4.5"
5"
5"
5"
WF
BF
OT F
ELF
Series
SBF
NAF
ASF
SCF
MBF
CCF
OMF
RWF
TMF
TLF
FMF
WF
BF
OTF
ELF
FF
PF
KWF
WLF
Finish1
ANBK
ANDB
ANDG
ANVG
ANPP
CM
CS
Black
Dark Bronze
Dark Green
Verde Green
Prime Painted
Custom Match
Custom Select
RAL colors
Manf. Code
AEL
Notes:
1 For finish specifications and color
options, please contact your local
AEL representative
16.5 "
15.5 "
12 "
AEL
12 "
5"
5"
5"
5"
FF
PF
KWF
WLF
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
125
Heritage WTA Series
Crossarms and Wall Bracket
Cast Aluminum
P R O D U C T
O V E R V I E W
Features:
INSTALLATION The crossarms shall slip-fit a post top tenon and
attach with socket set screws. The center finial shall be removable.
The wall bracket shall have four 9/16” dia. holes for mounting to the
wall. (Bracket mounting hardware furnished by others.) Both
crossarms and wall bracket shall have 3”O.D. tenons for luminaire
mounting.
MATERIALS The arm assemblies shall be heavy-wall, copper free,
cast aluminum produced from certified ASTM 356.1 ingot per ASTM
B-179-95a or ASTM B26-95. The center luminaire extension piece and
wall bracket mounting plate shall be aluminum, ASTM 6061 alloy, heat
treated to a T6 temper. All hardware shall be stainless steel. All
exterior hardware shall be tamper resistant.
O R D E R I N G
CONSTRUCTION The crossarms and wall brackets shall be one-piece
construction. For wall brackets, the arm shall be welded to a flat wall
plate. All welding shall be per ANSI/AWS D1.2-90. All welders shall be
certified per ANSI/AWS D1.2-90 Section 5.
Applications:
Streetscapes
Walkways
Pathways
Parks
I N F O R M AT I O N
AEL
Finish1
Series
WTAWB
WTA2
WTA28/2T
WTA28/4
WTA28/4T
126
One
Two
Three
Four
Five
Product Guide
ANBK
ANDB
ANDG
ANVG
ANPP
CM
CS
Example: W T A 2 8 / 2 T A N B K A E L
Manufacturing Code
Black
Dark Bronze
Dark Green
Verde Green
Prime Painted
Custom Match
Custom Select
RAL colors
AEL
Notes:
1 For finish specifications and color
options, please contact your local
AEL representative
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage WTA Series
Crossarms and Wall Bracket
Cast Aluminum
P R O D U C T
14"
3" O.D. x 3" high
Tenon (typical)
8"
O V E R V I E W
orientation
11.5"
9.5" x 13" Wall Bracket
Mounting Plate
(4) 9/16" ¯
Holes
WTAWB
(one-way wall mount)
orientation
orientation
27.5"
13.75"
Varies with
Luminaire
Center
Finial
22"
WTA28
WTA28/2 T
(two at 180 )
(two at 180 w/ one at center)
(Note: Dimensions typical for all WTA Series).
Center
Tenon
Center
Finial
orientation
orientation
WTA28/4
WTA28/4 T
(four at 90 )
(four at 90 w/one at center)
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
127
Heritage OS Series
Crossarms and Wall Bracket
Cast Aluminum
P R O D U C T
O V E R V I E W
Features:
INSTALLATION The crossarms shall slip-fit a 3" O.D.x 5" post top
tenon and attach with socket set screws. The center finial shall be
removable. The wall bracket shall have four 9/16” dia. holes for
mounting to the wall. (Bracket mounting hardware furnished by
others.) Both crossarms and wall bracket shall have 3” O.D. tenons
for luminaire mounting.
CONSTRUCTION The crossarms and wall brackets shall be one-piece
construction. The arms shall be welded to a center spool. For wall
brackets the arm shall be welded to a flat wall plate. All welding shall
be per ANSI/AWS D1.2-90. All welders shall be certified per
ANSI/AWS D1.2-90 Section 5.
MATERIALS The arms, finials, and tenons, shall be heavy-wall,
copper free, cast aluminum produced from certified ASTM 356.1 ingot
per ASTM B-179-95a or ASTM B26-95. The center spool and wall
bracket mounting plate shall be aluminum, ASTM 6061 alloy, heat
treated to a T6 temper. All hardware shall be stainless steel. All
exterior hardware shall be tamper resistant.
Applications:
O R D E R I N G
Streetscapes
Walkways
Pathways
Parks
I N F O R M AT I O N
AEL
Series
OSWB
OS26
OS26/2T
OS26/3
OS26/3T
OS26/4
OS26/4T
128
One
Two
Three
Three
Four
Four
Five
Product Guide
Finish2
ANBK
ANDB
ANDG
ANVG
ANPP
CM
CS
Example: O S 2 6 / 2 T A N B K A E L
Manufacturing Code
Black
Dark Bronze
Dark Green
Verde Green
Prime Painted
Custom Match
Custom Select
RAL colors
AEL
Notes:
1 For finish specifications and color
options, please contact your local
AEL representative
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage OS Series
Crossarms and Wall Bracket
Cast Aluminum
P R O D U C T
3" O .D . x 3 " high
Tenon (typical)
4.5"
O V E R V I E W
11.5"
orientation
6" x 8 " Wall Bracket
Mounting plate
6.5"
(4 ) 9/16" Ø
Holes
OSWR
(one -way wall mount)
orientation
orientation
26"
Varies with
Luminaire
Center
Finial
11"
OS26
(two at 180˚)
orientation
(N ot e: Dimensions
typical for all OS Series).
OS26/2T
(two at 180 ˚ w/ one at center )
orientation
23"
OS26/3
OS26/3T
(three at 120 ˚ w/ one at cent er )
(three at 120 ˚ )
orientation
orientation
OS26/4
(four at 90˚)
OS26/4T
(four at 90˚ w/ one at center )
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
129
Heritage Series
Orientation Guide
P R O D U C T
O V E R V I E W
Features:
This guide is to help plan the correct orientation of signs and accessories on the post. To facilitate correct orientation on a project, careful
planning and coordination with the factory is required.
Below is an illustration of a sample post with multiple accessories showing the orientation in relationship to the post door and the street.
Below is a sample sketch used to show the part number, mounting height, and orientation degrees for each accessory. The illustration of the post
base plan view shows the orientation of the parts in relationship to the post door and anchor bolts.
Street Sign
SS1B
0¡
Part #
Height
Orientation
FG-S
15’-6”
0 degrees
SS1B
14’-0”
180 degrees
SS1B
14’-0”
270 degrees
BA24H/1/BO
13’-0”
90 degrees
FPH4B
11’-6”
0 degrees
10’-0”
90 degrees
Weatherproof Receptacle
FG-S
180¡
270¡
Street Sign
SS1B
90¡
Banner Arm
BA24H/1/BO
Flagpole holder
FPH4B
0¡
BA24H/1/BO
Banner Arm
BA24H/1/BO
90¡
Post Elevation
10 ’0”
height from bottom of post
Post Base Plan View
Street sign
Curb
180¡
225¡
Anchors
Street
10’ 0” min. height
recommended for banner arms
Sign
135¡
270¡
90¡
45¡
315¡
0 degrees
Base door
Banner
Door
0¡
Receptacle and flagpole
130
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Heritage Series
Orientation Guide
P R O D U C T
O V E R V I E W
Below is a blank sketch to record the part #, mounting height and orientation degrees for your post accessories. Copy and paste your post base
plan view in the appropriate space below.
Part #
Height
Orientation
Accessory Center
Post Elevation
Post Base Plan View
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
131
Decorative Post Top Lighting
B A L L A S T
M AT R I C E S
Marietta Series LMD
Watts
120
03S
RN
05S
RH,RN
05M
XH
07S
RN, RH, CA, CT
07M
XH
10S
RH, RN,CA,CT
10V
XN, CA
10M
CA, XH
15S
RH,RN,CA
15M
XH
17V
CA, XN
17M
CA
25S
CA
25V
CA
25M
CA
208
XH, XN
XH
XN, XH, CA, CT
XH
XN, XH, CA, CT
CA
XH
XN, XH, CA
XH
CA
CA
CA
240
XH, XN
XH
XN, XH, CA, CT
XH
XN, XH, CA, CT
CA
XH
XN, XH, CA
XH
CA
CA
CA
CA
277
XH, XN
XH,
XN, XH, CA
XH
XN, XH, CA
CA
CA, XH
XN, XH, CA
XH
CA
CA
CA
CA
480
CA
CA
CA
-
DT1
XH, XN
XN, XH, CA
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
CA
DT2
XH, XN
XN, XH, CA
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
CA
MT1
XH,XN
XH
XN,XH, CA
XH
CA,XN,XH
CA
XH
XH,XN,CA
XH
CA
CA
CA,CT
CA
MT2
XH,XN
XH
XN,XH, CA
XH
CA, XN,XH
CA
XH
XH,XN, CA
XH
CA
CA
CA,CT
CA
MT7
XH,XN
XH
XN,XH, CA
XH
CA,XN,XH
CA
XH
XH,XN, CA
XH
CA
CA
CA,CT
CA
Marietta Series LMD, Continued
Watts
03S
05S
05M
07S
07M
10S
10V
10M
15S
15M
17V
17M
25S
25V
25M
TT1
XN, XH
XN, XH
XN, XH
XN, XH
CA
CA
TT7
XN, XH
XN, XH
XN, XH
XN, XH
CA
CA
TT3
XN, XH
XN, XH
XN, XH
XN, XH
CA
CA
347
XN, XH, CA, CT
XN, XH
XN, XH
XN, XH, CA
CA
CA
CA
Sumter Series LSH
Watts
120
03S
RN
05S
RH,RN
05M
XH
07S
RN, RH, CA, CT
07M
XH
10S
RH, RN,CA,CT
10V
XN, CA
10M
CA, XH
15S
RH,RN,CA
15M
XH
17V
CA, XN
17M
CA
25S
CA
25V
CA
25M
CA
208
XH, XN
XH
XN, XH, CA, CT
XH
XN, XH, CA, CT
CA
XH
XN, XH, CA
XH
CA
CA
CA
CA
CA
240
XH, XN
XH
XN, XH, CA, CT
XH
XN, XH, CA, CT
CA
XH
XN, XH, CA
XH
CA
CA
CA
CA
CA
277
XH, XN
XH,
XN, XH, CA, CT
XH
XN, XH, CA
CA
CA, XH
XN, XH, CA
XH
CA
CA
CA
CA
CA
480
CA
X
CA
CA
CA
CA
CA
CA
CA
DT1
XH, XN
XN, XH, CA
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
CA
CA
CA
DT2
XH, XN
XN, XH, CA
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
CA
CA
CA
MT1
XH,XN
XH
XN,XH, CA
XH
CA,XN,XH
CA
XH
XH,XN,CA
XH
CA
CA
CA
CA,CT
CA
Sumter Series LSH, Continued
Watts
03S
05S
05M
07S
07M
10S
10V
10M
15S
15M
17V
17M
25S
25V
25M
132
MT7
XH,XN
XH
XN,XH, CA
XH
CA,XN,XH
CA
XH
XH,XN, CA
XH
CA
CA
CA
CA,CT
CA
MT8
XH,XN
XH
XN,XH, CA
XH
CA,XN,XH
CA
XH
XH,XN,CA
XH
CA
CA
CA
CA,CT
CA
Product Guide
TT1
XN, XH
XN, XH
XN, XH
XN, XH
CA
CA
TT7
XN, XH
XN, XH
XN, XH
XN, XH
CA
CA
TT3
XN, XH
XN, XH
XN, XH
XN, XH
CA
CA
347
XN, XH, CA, CT
XN, XH
XN, XH
XN, XH, CA
CA
CA
CA
For photometric information, please visit our website,
www.americanelectriclighting.com
MT2
XH,XN
XH
XN,XH, CA
XH
CA, XN,XH
CA
XH
XH,XN, CA
XH
CA
CA
CA
CA,CT
CA
MT8
XH,XN
XH
XN,XH, CA
XH
CA,XN,XH
CA
XH
XH,XN,CA
XH
CA
CA
CA,CT
CA
Decorative Post Top Lighting
B A L L A S T
M AT R I C E S
Cresthill Series LCR - Classic, Sphere, Centennial, and Glass
Watts
03S
05S
05M
07S
07M
10S
10V
10M
15S
15M
17V
17M
25S
25V
25M
120
RN
RH,RN
XH
RN, RH,CA,CT
XH
RH, RN,CA,CT
XN, CA
CA, XH
RH,RN,CA
XH
CA, XN
CA
CA
CA
CA
208
XH, XN
XH
XN, XH,CA,CT
XH
XN, XH, CA, CT
CA
XH
XN, XH, CA
XH
CA
CA
CA
CA
CA
240
XH, XN
XH
XN, XH,CA,CT
XH
XN, XH, CA, CT
CA
XH
XN, XH, CA
XH
CA
CA
CA
CA
CA
277
XH, XN
XH,
XN, XH, CA
XH
XN, XH, CA
CA
CA, XH
XN, XH, CA
XH
CA
CA
CA
CA
CA
480
CA
CA
CA
CA
CA
CA
CA
CA
DT1
XH, XN
XN, XH,CA
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
CA
CA
CA
DT2
XH, XN
XN, XH, CA
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
CA
CA
CA
MT1
-XH,XN
XH
XN,XH,CA
XH
CA,XN,XH
CA
XH
XH,XN,CA
XH
CA
CA
CA
CA,CT
CA
MT2
XH,XN
XH
XN,XH,CA
XH
CA, XN,XH
CA
XH
XH,XN, CA
XH
CA
CA
CA
CA,CT
CA
MT7
XH,XN
XH
XN,XH,CA
XH
CA,XN,XH
CA
XH
XH,XN, CA
XH
CA
CA
CA
CA,CT
CA
MT8
XH,XN
XH
XN,XH,CA
XH
CA,XN,XH
CA
XH
XH,XN,CA
XH
CA
CA
CA
CA,CT
CA
Cresthill Series LCR - Classic, Sphere, Centennial, and Glass, Continued
Watts
03S
05S
05M
07S
07M
10S
10V
10M
15S
15M
17V
17M
25S
25V
25M
TT1
XN,XH
XN,XH
XN,XH
XN,XH
CA
CA
TT2
XN,XH
XN,XH
XN,XH
XN,XH
CA
CA
TT3
XN,XH
XN,XH
XN,XH
XN,XH
CA
CA
347
XN,XH,CA,CT
XN,XH
XN,XH
XN,XH,CA
CA
CA
CA
Lexington LLX
Watts
03S
05S
05M
07S
07M
10S
10V
10M
15S
15M
17V
17M
25S
25V
25M
120
RN
RH, RN
XH
RN, RH
XH
RH, RN, CA,
XN, CA
CA, XH
RH, RN, CA
XH
CA, XN
CA
CA
CA
CA
208
XH, XN
XH
XN, XH
XH
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
CA
240
XH, XN
XH
XN, XH
XH
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
CA
CA
277
XH, XN
XH,
XN, XH
XH
XN, XH, CA
CA
CA, XH
XN, XH, CA
XH
CA
CA
CA
CA
480
CA
CA
-
DT1
XH, XN
XN, XH
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
CA
DT2
XH, XN
XN, XH
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
CA
MT1
XH, XN
XH
XN, XH
XH
CA, XN, XH
CA
XH
XH, XN, CA
XH
CA
CA
CA
CA
MT2
XH, XN
XH
XN, XH
XH
CA, XN, XH
CA
XH
XH, XN, CA
XH
CA
CA
CA
CA
MT7
XH, XN
XH
XN, XH
XH
CA, XN, XH
CA
XH
XH, XN, CA
XH
CA
CA
CA
CA
MT8
XH, XN
XH
XN, XH
XH
CA, XN, XH
CA
XH
XH, XN, CA
XH
CA
CA
CA
CA
Lexington LLX, Continued
Watts
03S
05S
05M
07S
07M
10S
10V
10M
15S
15M
17V
17M
25S
25V
25M
TT1
XN, XH
XN, XH
XN, XH
XN, XH
CA
CA
TT7
XN, XH
XN, XH
XN, XH
XN, XH
CA
CA
TT3
XN, XH
XN, XH
XN, XH
XN, XH
CA
CA
347
XN, XH, CA, CT
XN, XH
XN, XH
XN, XH, CA
CA
CA
CA
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
133
Decorative Post Top Lighting
L AU SC TT M
S
PB RA OL D
O VA ET R VI CI E W
Syracuse LSY
Watts
03S
05S
05M
07S
07M
10S
10V
10M
15S
15M
17V
17M
25S
25V
25M
120
RN
RH, RN
XH
RN, RH
XH
RH, RN, CA, CT
XN, CA
CA, XH
RH, RN, CA
XH
CA, XN
CA
CA
CA
CA
208
XH, XN
XH
XN, XH
XH
XN, XH, CA, CT
CA
XH
XN, XH, CA
XH
CA
CA
CA
240
XH, XN
XH
XN, XH
XH
XN, XH, CA, CT
CA
XH
XN, XH, CA
XH
CA
CA
CA
CA
277
XH, XN
XH,
XN, XH
XH
XN, XH, CA
CA
CA, XH
XN, XH, CA
XH
CA
CA
CA
CA
480
CA
CA
-
DT1
XH, XN
XN, XH
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
CA
DT2
XH, XN
XN, XH
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
CA
MT1
XH, XN
XH
XN, XH
XH
CA, XN, XH
CA
XH
XH, XN, CA
XH
CA
CA
CA, CT
CA
MT2
XH, XN
XH
XN, XH
XH
CA, XN, XH
CA
XH
XH, XN, CA
XH
CA
CA
CA, CT
CA
MT7
XH, XN
XH
XN, XH
XH
CA, XN, XH
CA
XH
XH, XN, CA
XH
CA
CA
CA, CT
CA
MT8
XH, XN
XH
XN, XH
XH
CA, XN, XH
CA
XH
XH, XN, CA
XH
CA
CA
CA, CT
CA
Syracuse LSY, Continued
Watts
03S
05S
05M
07S
07M
10S
10V
10M
15S
15M
17V
17M
25S
25V
25M
TT1
XN, XH
XN, XH
XN, XH
XN, XH
CA
CA
TT7
XN, XH
XN, XH
XN, XH
XN, XH
CA
CA
TT3
XN, XH
XN, XH
XN, XH
XN, XH
CA
CA
347
XN, XH, CA, CT
XN, XH
XN, XH
XN, XH, CA
CA
CA
CA
Victorian Series LVI
Watts
03S
05S
05M
07S
07M
10S
10V
10M
15S
15M
17V
17M
25S
25V
120
RN
RH,RN
XH
RN, RH,CA,CT
XH
RH, RN,CA,CT
XN, CA
CA, XH
RH,RN,CA
XH
CA, XN
CA
CA
CA
208
XH, XN
XH
XN, XH,CA,CT
XH
XN, XH, CA, CT
CA
XH
XN, XH, CA
XH
CA
CA
CA
CA
240
XH, XN
XH
XN, XH,CA,CT
XH
XN, XH, CA, CT
CA
XH
XN, XH, CA
XH
CA
CA
CA
CA
277
XH, XN
XH,
XN, XH, CA
XH
XN, XH, CA
CA
CA, XH
XN, XH, CA
XH
CA
CA
CA
CA
480
CA
CA
CA
CA
CA
CA
CA
DT1
XH, XN
XN, XH,CA
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
CA
CA
DT2
XH, XN
XN, XH, CA
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
CA
CA
MT1
XH,XN
XH
XN,XH,CA
XH
CA,XN,XH
CA
XH
XH,XN,CA
XH
CA
CA
CA
CA,CT
MT2
XH,XN
XH
XN,XH,CA
XH
CA, XN,XH
CA
XH
XH,XN, CA
XH
CA
CA
CA
CA,CT
MT7
XH,XN
XH
XN,XH,CA
XH
CA,XN,XH
CA
XH
XH,XN, CA
XH
CA
CA
CA
CA,CT
MT8
XH,XN
XH
XN,XH,CA
XH
CA,XN,XH
CA
XH
XH,XN,CA
XH
CA
CA
CA
CA,CT
25M
CA
CA
CA
CA
CA
CA
CA
CA
CA
CA
CA
Victorian Series LVI, Continued
Watts
03S
05S
05M
07S
07M
10S
10V
10M
15S
15M
17V
17M
25S
25V
25M
134
TT1
XN,XH
RXN,XH
XN,XH
XN,XH
CA
CA
TT2
XN,XH
XN,XH
XN,XH
XN,XH
CA
CA
Product Guide
TT3
XN,XH
XN,XH
XN,XH
XN,XH
CA
CA
347
XN,XH,CA,CT
XN,XH
XN,XH
XN,XH,CA
CA
CA
CA
For photometric information, please visit our website,
www.americanelectriclighting.com
Decorative Post Top Lighting
O R D E RB IANL GL AI SN TF OMR AMT AR TI IC OE NS
Yorktown LYT
Watts
03S
05S
05M
07S
07M
10S
10V
10M
15S
15M
17V
17M
25S
25V
25M
120
RN
RH,RN
RN,CA
XN,XH
RH,RN,CA
XN,CA
CA
RN,CA
XN,XH
-
208
CA
CA
-
240
XH,XN
XH
-
277
CA
CA
-
480
CA
CA
-
MT1
XH,XN
XH
XN,XH
XH
CA,XN,XH
CA
CA,XH
XH,XN,CA
XH
CA
CA
CA,XN,XH
CA
CA,XH
MT2
XH,XN
XH
XN,XH
XH
XN,XH
CA
XH
XH,XN
XH
CA
CA
XN,XH
CA
XH
MT7
XH,XN
XH
XN,XH
XH
XN,XH
CA
XH
XH,XN
XH
CA
CA
XN,XH
CA
XH
MT8
XH,XN
XH
XN,XH
XH
XN,XH
CA
XH
XH,XN
XH
CA
CA
XN,XH
CA
XH
Branson LBR
Watts
120
03S
RN
05S
RH,RN
05M
XH
07S
RN, RH,CA,CT
07M
XH
10S
RH, RN,CA,CT
10V
XN, CA
10M
CA, XH
15S
RH,RN,CA
15M
XH
17V
CA, XN
17M
CA
25S
CA
25V
CA
25M
CA
208
240
XH, XN
XH, XN
XH
XH
XN, XH,CA,CT XN, XH,CA,CT
XH
XH
XN, XH, CA, CT XN, XH, CA, CT
CA
CA
XH
XH
XN, XH, CA
XN, XH, CA
XH
XH
CA
CA
CA
CA
CA
CA
CA
CA
CA
CA
277
480
XH, XN
XH,
XN, XH, CA CA
XH
XN, XH, CA CA
CA
CA, XH
XN, XH, CA CA
XH
CA
CA
CA
CA
CA
CA
CA
CA
CA
CA
DT1
XH, XN
XN, XH,CA
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
CA
CA
CA
DT2
XH, XN
XN, XH, CA
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
CA
CA
CA
MT1
XH,XN
XH
XN,XH,CA
XH
CA,XN,XH
CA
XH
XH,XN,CA
XH
CA
CA
CA
CA,CT
CA
MT2
XH,XN
XH
XN,XH,CA
XH
CA, XN,XH
CA
XH
XH,XN, CA
XH
CA
CA
CA
CA,CT
CA
MT7
XH,XN
XH
XN,XH,CA
XH
CA,XN,XH
CA
XH
XH,XN, CA
XH
CA
CA
CA
CA,CT
CA
MT8
XH,XN
XH
XN,XH,CA
XH
CA,XN,XH
CA
XH
XH,XN,CA
XH
CA
CA
CA
CA,CT
CA
TT1
XN,XH
XN,XH
XN,XH
XN,XH
CA
CA
TT7
XN,XH
XN,XH
XN,XH
XN,XH
CA
CA
TT3
347
XN,XH XN,XH,CA,CT
XN,XH
XN,XH
XN,XH
XN,XH
XN,XH XN,XH,CA
CA
CA
CA
CA
CA
Depot LDP
Watts
03S
05S
05M
07S
07M
10S
10V
10M
15S
15M
17V
17M
17V
17M
120
RN
RH,RN
XH
RN, RH
XH
RH, RN,CA,CT
XN, CA
CA, XH
RH,RN,CA
XH
CA, XN
CA
XN,CA,CT
CA,CT
208
XH, XN
XH
XN, XH
XH
XN, XH, CA, CT
CA
XH
XN, XH, CA
XH
CA
CA
CA,CT
CA,CT
240
XH, XN
XH
XN, XH
XH
XN, XH, CA, CT
CA
XH
XN, XH, CA
XH
CA
CA
-
277
XH, XN
XH,
XN, XH
XH
XN, XH, CA
CA
CA, XH
XN, XH, CA
XH
CA
CA
CA,CT
CA,CT
480
CA
CA
CA,CT
CA,CT
DT1
XH, XN
XN, XH
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
-
DT2
XH, XN
XN, XH
XN, XH, CA
CA
XH
XN, XH, CA
XH
CA
CA
-
MT1
XH,XN
XH
XN,XH
XH
CA,XN,XH
CA
XH
XH,XN,CA
XH
CA
CA
CA,CT
CA,CT
See pages 259-264 for a complete listing
of Frequently Ordered Products
MT2
XH,XN
XH
XN,XH
XH
CA,XN,XH
CA
XH
XH,XN, CA
XH
CA
CA
CA,CT
CA,CT
MT7
XH,XN
XH
XN,XH
XH
CA, XN,XH
CA
XH
XH,XN, CA
XH
CA
CA
CA,CT
CA,CT
MT8
XH,XN
XH
XN,XH
XH
CA,XN,XH
CA
XH
XH,XN,CA
XH
CA
CA
CA,CT
CA,CT
Product Guide
135
Decorative Post Top Lighting
B A L L A S T
M AT R I C E S
American Revolution Series 247
Watts
05S
07S
10S
10V
15S
17V
17M
120
RH, RN
RH, CA, CT, RN, MR
CA, CT, MR, RH, RN
XH, XN, CA, CT
RN, RH, CA, CT, MR
XN, XH, CA, CT
CA
208
XH, XN
XH, CA, CT, XN
XH, CA, CT, XN
CA
CA, CT, XN, XH
CA
CA
220
240
XH, XN
- XH, CA, CT, MR, XN
- XH, CA, CT, MR, XN
CA, CT
- CA, CT, XN, XH, MR
CA
CA, CT, RN, RH
CA
277
XH, XN
XH, CA, XN
CA, XH, XN
XN, XH, CA
XN, XH, CA
CA
CA
480
DT1
XH, XN
MR
XH, XN, CA, CT, MR
CA
CA, CT, XH, MR, XN
CT
CT
CA, MR XN, XH, CA, CT, MR
CA, CT
CT
CA
CA
DT2
XH, XN
XH, XN, CA, CT, MR
CA, CT, MR, XH, XN
CT, CA
XN, XH, CA, CT, MR
CT, CA
CA
DT3
MR
CT
MR
CT
-
DT4
MR
CT
MR
CT
-
MT1
XH, XN
XH, XN, CA
CA, XN, XH
CA
XN, XH, CA
CA
CA
MT2
XN,XH
XH,XN,CA,
CA,XN,XH
CA
XN,XH,CA
CA
CA
American Revolution Series 247, Continued
Watts
05S
07S
10S
10V
15S
17V
17M
MT7
XN, XH
XH, XN, CA,
CA, XN, XH
CA
XN, XH, CA
CA
CA
MT8
XN, XH
XH, XN, CA
CA, XN, XH
CA
XN, XH, CA
CA
CA
TT1
XN, XH
XN, XH
XN, XH
XN, XH
-
TT7
XN, XH
XN, XH
XN, XH
XN, XH
-
TT3
XN, XH
XN, XH
XN, XH
XN, XH
-
347
XN, XH, CA, CT
XN, XH
XN, XH
XN, XH, CA
-
Contempo Series 245
Watts
03S
05S
07S
07M
10S
10V
10M
15S
13S
14S
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
120
RN, RH
RH, RN
RH, CA, CT, RN, MR
XH
CA, CT, MR, RH, RN
XH, XN, CA, CT
XH
RN, RH, CA, CT, MR
RN, RH
RN, RH
XN, XH, CA, CT
CA
CA, CT, XN, XH, MR
CA, CT, XN, XH, MR
XN, XH, CA, CT
CA, CT
CA, MR
XH, XN, CT, CA, MR
CT, CA
CT, CA
208
XH, XN
XH, CA, CT, XN
XH
XH, CA, CT, XN
CA
XH
CA, CT, XN, XH
CA
CA
CA, CT
CA, CT
CA
CA
CA
CT, CA, RN, RH
CT, CA
CT, CA
220
230
RN, RH
RN, RH
CA
RN, RH
CA
CA
RN, RH
-
240
277
XH, XN
XH, XN
XH, CA, CT, MR, XN
XH, CA, XN
XH
XH
XH, CA, CT, MR, XN
CA, XH, XN
CA, CT
XN, XH, CA
XH
XH
CA, CT, XN, XH, MR
XN, XH, CA
CA, CT, RN, RH
CA
CA
CA
RN, RH, CA, CT, XN, XH, MR CA, CT
RN, RH, CA, CT, MR
CA, CT
RN, RH, CA, CT
CA
CA, CT
CA
CA, MR
RN, RH, XN, XH, CA, CT, MR
CA
CT, CA
CA
CT, CA
CA
480
MR
CA
CT
CA, MR
CA, CT
CA
CA, CT, MR
CA, CT, MR
CA, CT
CA, CT
CA, MR
CA, MR
CA, CT
CA, CT
DT1
XH, XN
XH, XN, CA, CT, MR
XH
CA, CT, XH, MR, XN
CT
XH
XN, XH, CA, CT, MR
CT
CA
CA, CT, XN, XH, MR
XN, XH, CA, CT, MR
CA, CT
CA, CT
CA, MR
XN, XH, CA, CT, MR
CA, CT
CA, CT
Contempo Series 245, Continued
Watts
03S
05S
07S
07M
10S
10V
10M
15S
13S
14S
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
136
MT1
XH, XN
XH, XN, CA
XH
CA, XN, XH
CA
XH
XN, XH, CA
CA
CA
CA, CT
CA, CT
CA
CA
CA
CA
CA
CA
MT2
XN, XH
XH, XN, CA,
XH
CA, XN, XH
CA
XH
XN, XH, CA
CA
CA
CA, CT
CA, CT
CA
CA
CA
CA
CA
CA
Product Guide
MT7
XN, XH
XH, XN, CA,
XH
CA, XN, XH
CA
XH
XN, XH, CA
CA
CA
CA, CT
CA, CT
CA
CA
CA
CA
CA
CA
MT8
XN, XH
XH, XN, CA
XH
CA, XN, XH
CA
XH
XN, XH, CA
CA
CA
CA, CT
CA, CT
CA
CA
CA
CA
CA
TT1
XN, XH
TT3
XN, XH
TT7
XN, XH
347
XN, XH, CA, CT
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH
CA
CA, CT
CA
CA
-
XN, XH
CA
CA, CT
CA
CA
-
XN, XH
CA
CA, CT
CA
CA
-
XN, XH, CA
CA
CA, CT
CA
CA
CA
-
For photometric information, please visit our website,
www.americanelectriclighting.com
DT2
XH, XN
XH, XN, CA, CT, MR
XH
CA, CT, MR, XH, XN
CT, CA
XH
XN, XH, CA, CT, MR
CT, CA
CA
CA, CT, XN, XH, MR
XN, XH, CA, CT, MR
CA, CT
CA, CT
CA, MR
XN, XH, CA, CT, MR
CA, CT
CA, CT
DT3
MR
CT
MR
CT
MR
MR
CT
CT
MR
MR
CT
CT
DT4
MR
CT
MR
CT
MR
MR
CT
CT
MR
MR
CT
CT
Decorative Post Top Lighting
B A L L A S T
M AT R I C E S
TwistPack Series TWT
Wattage
05S
05M
07S
07M
10S
10M
10V
15S
15M
17M
17V
25S
25M
25V
120
RN, RH, XN, XH
XN, XH
RN, RH, XN, XH, CA, CT
XN, XH
RN, RH, XN, XH, CA, CT
XN, XH, CA
XN, XH, CA
RN, RH, XN, XH, CA, CT
XN, XH, CA
CA, CT
XN, XH, CA, CT
XN, XH, CA, CT
CA, CT
XN, XH, CA, CT
208
XN, XH
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA, CT
CA, CT
CA, CT
CA, CT
CA, CT
240
277
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH, CA, CT
XN, XH, CA
XN, XH
XN, XH
XN, XH, CA, CT
XN, XH, CA, CT
XN, XH
XN, XH, CA
XN, XH, CA
XN, XH, CA
XN, XH, CA, CT
XN, XH, CA, CT
XN, XH
RN, RH, XN, XH, CA
CA, CT
CA
CA, CT
RN, RH, CA
RN, RH, XN, XH, CA, CT
CA, CT
CA, CT
CA
RN, RH, CA, CT
CA
347
XN, XH
XN, XH, CT
XN, XH
XN, XH, CT
XN, XH
XN, XH
XN, XH, CT
XN, XH, CA
CA
CA
CA
600
CT
CT
CT
CT
CT
CT
CT
CT
DT1
XN, XH
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA
XN, XH, CA, CT
XN, XH, CT
CA, CT
CA, CT
XN, XH
CT
CT
DT2
TT1
XN, XH
XN, XH
XN, XH, CA, CT XN, XH
XN, XH
XN, XH
XN, XH, CA, CT XN, XH
XN, XH
XN, XH
XN, XH, CA
XN, XH
XN, XH, CA, CT XN, XH
XN, XH, CT XN, XH, CA
CA, CT
CA, CT
XN, XH
CA
CT
CA, CT
CT
CA, CT
TT7
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH, CA
CA
CA, CT
CA, CT
TwistPack Series TWT, Continued
Wattage
05S
05M
07S
07M
10S
10M
10V
15S
15M
17M
17V
25S
25M
25V
TT3
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH, CA
CA
CA, CT
CA, CT
MT1
XN, XH
XN, XH
XN, XH, CA
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA
CA
CA, CT
CA
CA
MT8
XN, XH
XN, XH
XN, XH, CA
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA
CA
CA, CT
CA
CA
MT2
XN, XH
XN, XH
XN, XH, CA
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA
CA
CA, CT
CA
CA
MT7
XN, XH
XN, XH
XN, XH, CA
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA
CA
CA, CT
CA
CA
Series 870
Watts
05S
07S
10S
10V
15S
17V
17M
120
RN
RN, RH, CA, CT
RN, RH, CA, CT
XN, XH, CT
RN, RH, CA, CT
XN, XH, CA, CT
CA
208
XN, XH, CA, CT
XN, XH, CA, CT
XN, XH, CA, CT
CA
CA
240
XN, XH, CA, CT
XN, XH, CA, CT
CT
XN, XH, CA, CT
RN, RH, CA, CT
CA
277
XN, XH, CA
XN, XH, CA, CT
XN, XH, CA, CT
RN, RH, CA
CA
480
CA
CA
CA
CA
CA
DT1
XN, XH, CA, CT
XN, XH, CA, CT
CT
XN, XH, CA, CT
-
DT2
XN, XH, CA, CT
XN, XH, CA, CT
CT
XN, XH, CA, CT
-
MT1
CA, CT
CA, CT
CA, CT
CA
CA
MT2
MT7
CA, CT CA, CT
CA, CT CA, CT
CA, CT CA, CT
CA
CA
CA
CA
MT8
CA, CT
CA, CT
CA, CT
CA
CA
TT1
XN, XH
XN, XH
XN, XH
CA
CA
Series 870, Continued
Watts
05S
07S
10S
10V
15S
17V
17M
TT3
XN, XH
XN, XH
XN, XH
CA
CA
TT7
XN, XH
XN, XH
XN, XH
CA
CA
347
XN, XH, CT
XN, XH, CT
XN, XH
CA
CA
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
137
Decorative Post Top Lighting
B A L L A S T
M AT R I C E S
Georgian Series GRP
Wattage
05S
05M
07S
07M
10S
10M
10V
15S
15M
17M
17V
120
RN, RH, XN, XH
XN, XH
RN, RH, XN, XH, CA, CT
XN, XH
RN, RH, XN, XH, CA, CT
XN, XH, CA
XN, XH, CA
RN, RH, XN, XH, CA, CT
XN, XH, CA
CA, CT
XN, XH, CA, CT
208
XN, XH
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA, CT
CA, CT
240
XN, XH
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA, CT
RN, RH, CA, CT
277
XN, XH
XN, XH
XN, XH, CA
XN, XH
XN, XH, CA, CT
XN, XH, CA
XN, XH, CA
XN, XH, CA, CT
RN, RH, XN, XH, CA
CARN, RH, CA
347
XN, XH
XN, XH, CT
XN, XH
XN, XH, CT
XN, XH
XN, XH
XN, XH, CT
XN, XH, CA
CT
-
600
CT
CT
CT
CA, CT
CT
DT1
XN, XH
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA, CT
CA, CT
Georgian Series GRP, Continued
Wattage
05S
05M
07S
07M
10S
10M
10S
15S
15M
17M
17V
138
TT3
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH, CA
-
MT1
XN, XH
XN, XH
XN, XH, CA
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA
CA
Product Guide
MT8
XN, XH
XN, XH
XN, XH, CA
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA
CA
MT2
XN, XH
XN, XH
XN, XH, CA
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA
CA
MT7
XN, XH
XN, XH
XN, XH, CA
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA
CA
For photometric information, please visit our website,
www.americanelectriclighting.com
DT2
XN, XH
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA, CT
XN, XH
XN, XH, CA
XN, XH, CA, CT
XN, XH
CA, CT
TT1
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH, CA
-
TT7
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH
XN, XH, CA
-
SECURITY LIGHTING
315 Series ...............................................................140
NEMA Head 11........................................................142
NEMA Head Package Series 11 PKG .................144
Series 11 “L” Package...........................................146
Series 110 ................................................................148
Dusk To Dawn Series DTD....................................150
Series 165 ................................................................152
Accessories ............................................................154
Ballast Matrices .....................................................155
American Electric Lighting™
315 Series Security Luminaire
Rural Security Lighting
Cobrahead with power door and security lighting optics
P R O D U C T
O V E R V I E W
Features:
NEW
Die-cast secondary Power Pad door places all electrical components on one
easily interchangeable module with quick disconnects to main fixture housing.
External two-bolt mast arm mount provides easy, secure installation and
adjustability for arms from 1-1/4" to 2" (32mm to 51mm) diameter.
Wildlife shield is cast into the housing (not a separate piece) and is easily
adjustable for 1-1/4" or 2" (32mm to 51mm) mast arms.
Anodized aluminum reflectors provide uniform lighting distribution with acrylic
open-bottom refractor.
NEMA wattage label, terminal block and NEMA photocontrol receptacle are
standard.
Includes open-bottom acrylic optics, DTL electronic photo control, lamp,
24” welded arm with 1-1/4” diameter and hardware.
This fixture comes with a CWA (Constant Wattage Auto Transformer) ballast,
that is designed to keep the lamp operational where line voltage dips are
an issue.
Applications:
Security lighting
Rural locations
Residential street
Remote storage areas
E39 mogul socket standard.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
Complies with ANSI: C136.2, C136.10, C136.15.
27-1/64"
(686)
13-5/16"
(333.5)
12-15/16"
(308)
Effective Projected Area (EPA)
The EPA for the Horizontal Luminaire Series 315 is 0.9 sq. ft.
Approx. Wt. = 19 lbs.
140
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
315 Series Security Luminaire
Rural Security Lighting
Cobrahead with power door and security lighting optics
O R D E R I N G
I N F O R M AT I O N
Example: 3 1 5 1 5 S C A M T 1 R 5 B A E C P K
Ordering Information:
Catalog Number
315 07S CA MT1 R5 BA EC PK
Description
70W HPS, Multi-tap wired 120V, CWA, Type V, Encapsulated starter
315 10S CA MT1 R5 BA EC PK
100W HPS, Multi-tap wired 120V, CWA, Type V, Encapsulated starter
315 15S CA MT1 R5 BA EC PK
150W HPS, Multi-tap wired 120V, CWA, Type V, Encapsulated starter
315 17V CA MT1 R5 BA PK
175W MV, Multi-tap wired 120V, CWA, Type V
315 17M CA MT1 R5 BA PK
175W MH, Multi-tap wired 120V, CWA, Type V
Package includes open-bottom acrylic optics,
DTL photocontrol, lamp, 24”welded arm with
1-1/4” diameter and hardware in single carton.
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
141
NEMA Head Series 11
Security Lighting
50-250W HPS, 100-250W MV, 35W LPS
P R O D U C T
O V E R V I E W
Features:
Die-cast aluminum head meets NEMA dimension standards.
For quick, easy installation of mast arm, a cast-in external slipfitter is used for
a secure mounting.
Star Friendly™ cutoff distribution pattern available.
Available in a variety of IES light distribution patterns , including full cutoff.
Tools are not required to install reflector and refractor.
Available for arm size 1-1/4" (standard) and 2" fitter.
Open-bottom acrylic, polycarbonate, or glass.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Suitable for -30°C MH & MV / -40°C HPS.
Complies with ANSI: C136.2, C136.6, C136.10
Applications:
Security areas
Storage yards
Loading areas
Receiving areas
DIMENSIONS
17-3/8"
(447)
A
16"
(406)
B
Full Cutoff (FC)
A
B
Mercury Vapor
12”
15-1/2”
High Pressure Sodium
12”
15-1/2”
Low Pressure Sodium
12”
21-3/4”
Approx. Wt. = 16 lbs.
142
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
NEMA Head Series 11
Security Lighting
50-250W HPS, 100-250W MV, 35W LPS
O R D E R I N G
I N F O R M AT I O N
Example: 1 1 1 0 S R N 1 2 0 R 5 B A
Wattage / Source
Series
11 NEMA
Head
05
07
10
15
17
20
25
50 W
70 W
100 W
150 W
175 W
200 W
250 W
Voltage
Ballast
RN Reactor Normal
Power Factor
XN High Reactance / Lag
Normal Power Factor
L LPS
S HPS
V MV
Refer to the ballast matrix on
page 155 for compatibility.
120
208
230
240
277
347
MT1
MT8
MT2
MT7
TT1
TT7
TT3
120V
208V
230V
240V
277V
347V
120V Multi-tap
208V Multi-tap
240V Multi-tap
277V Multi-tap
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Distribution
R2
R3
R4
R5
RX
RO
Type II
Type III
Type IV
Type V
Type II 4-way1
No optics
Optics
LO
BA
BP
FC
BG
Less Optics
Open-Bottom Acrylic
Open-Bottom Polycarbonate
Full Cutoff2
Open-Bottom Glass3
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
4
Mast Arm
M4 24" arm
M3 30" arm
Photocontrol Receptacle
NR
5
No Photocontrol Receptacle
Supply Wire6
SW5 Pre-wire 5'
PW5 Wired to terminal block 5'
(for more options see page 154)
Starter7
(blank) Open board standard
EC Encapsulated starter
SN No Ignitor (use self-igniting lamp)
Fitter Size
(blank) 1-1/4“ fitter
H2 2” fitter set for 1-1/4“
Lamp
LC Lamp Included, Clear
LD Lamp Included, Deluxe/Coated
LG Self-Igniting Lamp8
Misc.
PC
NL
DPC
LA
Photocontrol Included per
Voltage Specified
NEMA Label
DTL Control
Lightning Arrestor
Notes:
1
2
3
4
5
6
7
8
See pages 259-264 for a complete listing
of Frequently Ordered Products
BA and BG options only
Available in R5 distribution only
Not available in R4 distribution
Available in 1 ¼" aluminum only
Not available with PC or DPC option
Standard with #14 copper solid, black-white, THHN
HPS only
Requires SN option
Product Guide
143
NEMA Head Package Series 11 PKG
Security Light
50-250W HPS, 100-250W MV
P R O D U C T
O V E R V I E W
Features:
Die-cast aluminum head meets NEMA dimension standards.
For quick easy installation of mast arm, a cast-in external slipfitter is used for a
secure mounting.
Available in a variety of IES light distribution patterns including full cutoff.
Star Friendly™ cutoff distribution patterns available.
Tools are not required to install reflector and refractor.
Includes 24”, 1-1/4” diameter mast arm with welded brackets, lamp,
photocontrol, 5’ of supply wire and hardware.
All components in single carton.
Open-bottom acrylic, polycarbonate or glass.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Suitable for -30°C MH & MV / -40°C HPS.
Applications:
Complies with ANSI: C136.2, C136.6, C136.10
Security areas
Storage yards
Loading areas
Receiving areas
DIMENSIONS
18.8"
(478)
Full Cutoff (FC)
12"
(305)
32.4"
(823)
19 3/8"
(492)
16"
(406)
34 1/2"
(876)
Note: Package includes welded bracket, 24” mast arm 1-1/4”
diameter, lamp, photocontrol, 5’ of supply wire and hardware.
Approx. Wt. = 18 lbs.
144
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
NEMA Head Package Series 11 PKG
Security Light
50-250W HPS, 100-250W MV
O R D E R I N G
I N F O R M AT I O N
Example: 1 1 P K G 1 5 S R N 1 2 0 R 5 B A E C
Wattage / Source
Series
11PKG NEMA Head
Package
05
07
10
15
17
20
25
50 W
70 W
100 W
150 W
175 W
200 W
250 W
S HPS
V MV
Ballast
RN Reactor Normal
Power Factor
XN High Reactance/Lag
Normal Power Factor
Refer to the ballast matrix on
page 155 for compatibility.
Voltage
120
208
230
240
277
347
MT1
MT8
MT2
MT7
TT1
TT7
TT3
Optics
Distribution
120V
208V
230V
240V
277V
347V
120V Multi-tap
208V Multi-tap
240V Multi-tap
277V Multi-tap
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
R2
R3
R4
R5
RX
Type II
Type III
Type IV
Type V
Type II 4-way1
BA Open-Bottom
Acrylic
BP Open-Bottom
Polycarbonate
FC Full Cutoff2
BG Open-Bottom Glass3
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Photocontrol (per voltage specified)
(blank) Photocontrol standard
DPC DTL Control
Starter4
(blank) Open board (standard)
EC Encapsulated starter
SN No Ignitor (use self-igniting lamp)
Lamp
(blank)
LD
LG
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Self-Igniting Lamp5
Misc.
NL
NEMA Label
Notes:
1
2
3
4
5
Available in BG or BA optics
Available in R5 distribution only
Not available in R4 distribution
Available in HPS only
Requires SN option
Note: Package includes welded bracket, 24” mast arm with
1-1/4” diameter, lamp, photocontrol, 5’ of supply wire and
hardware.
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
145
Series 11 “L” Package
Security Light
50-150W HPS, 175-250W MV
P R O D U C T
O V E R V I E W
Features:
Die-cast aluminum head meets NEMA dimension standards
For quick easy installation of mast arm, a cast-in external slipfitter is used for
a secure mounting
Available in a variety of IES light distributions patterns
Includes 18” mast arm, lamp, photocontrol, pre-wire, and hardware
All components in single carton
Open bottom acrylic
All electrical components warranted by American Electric Lighting's 6-year
guarantee
Suitable for -30°C MH & MV / -40°C HPS
Complies with ANSI: C136.2, C136.6, C136.10
UL Listed for wet locations
Applications:
Rural areas
Area lighting
Small businesses
DIMENSIONS
18.8"
(478)
12"
(305)
28.5"
(724)
Note: Package includes 18” mast arm, lamp, photocontrol,
pre-wire and hardware.
Approx. Wt. = 18 lbs.
146
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Series 11 “L” Package
Security Light
50-150W HPS, 175-250W MV
O R D E R I N G
I N F O R M AT I O N
Example: 1 1 L 1 7 V X N 1 2 0 R 5 B A
Wattage / Source
Series
05
07
10
15
17
20
25
11L Security
Package
50 W
70 W
100 W
150 W
175 W
200 W
250 W
S HPS
V MV
Refer to the ballast matrix on
page 155 for compatibility.
Ballast
RN Reactor Normal Power
Factor
XN High Reactance / Lag
Normal Power Factor
Voltage
120
230
240
277
347
MT1
MT8
MT2
MT7
TT1
TT7
TT3
Distribution
120V
R5 Type V
230V
240V
277V
347V
120V Multi-tap
208V Multi-tap
240V Multi-tap
277V Multi-tap
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Optics
BA Open -Bottom Acrylic
Options
Photocontrol (per voltage specified)
(blank) Photocontrol (standard)
DPC DTL Control
Notes:
Package includes 18” mast arm, lamp, photocontrol, and
hardware.
Mast Arm
WA Welded Arm (24” mast arm)
Listing
(blank)
CS
UL Listed (standard)
CSA certified
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
147
Series 110
Security Light
50W - 150W HPS
P R O D U C T
O V E R V I E W
Features:
Die-cast aluminum ballast housing for cool operation.
Electrical components are easily accessible.
Available in a variety of IES light distribution patterns.
Tools are not required to install sag or flat lens.
All components in single carton.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
NEMA label standard.
1-1/4” Mast arm only.
Suitable for -30°C MH & MV / -40°C HPS.
Complies with ANSI: C136.2, C136.10
Shown with the SA lens option
E39 Mogul Socket standard.
Applications:
Rural areas
Small businesses
Storage lots
Security lighting
Roadway lighting
General area lighting
DIMENSIONS
7-27/32"
(199 mm)
23-1/16"
(585 mm)
12-3/32"
(307 mm)
Approx. Wt. = 15 lbs.
148
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Series 110
Security Light
50W - 150W HPS
O R D E R I N G
I N F O R M AT I O N
Example: 1 1 0 1 0 S R N 1 2 0 R 1 L C P C
Wattage / Source
Series
110 Horizontal
Security
05
07
10
13
14
15
17
50 W
70 W
100 W
130 W
140 W
150 W
170 W
S HPS
M MH
V MV
Refer to the ballast matrix on
page 155 for compatibility.
Ballast
Voltage
RN Reactor Normal Power
Factor
RH Reactor High Power
Factor
XN High Reactance/Lag
Normal Power Factor
XH High Reactance/Lag
High Power Factor
CA CWA
120 120V
208 208V
220 220V
230 230V
240 240V
277 277V
480 480V
MT1 120V Multi-tap
MT8 208V Multi-tap
MT2 240V Multi-tap
MT7 277V Multi-tap
DT1 Dual-tap
120/240 wired
120V
DT2 Dual-tap
120/240 wired
240V
Distribution
R1 Type I
Lens
(blank)
SA
SP
FG
No Lens
Open Bottom
Sag Acrylic
Sag Polycarbonate
Flat Glass
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle1
PB Phosphor Bronze Contacts
Lamp
LC
LD
Lamp Included, Clear
Lamp Included, Deluxe
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3-Wire Operation (L1, N, L2
Position)
Misc.
PC Photocontrol Included per
Voltage Specified
SS Stainless Steel Fasteners (external)
SH Shorting Cap
PK Package Includes Photocontrol,
Lamp, 24” Welded Arm, 1-1/4”
Diameter 5’ Supply Wire
NN No NEMA Label
Notes:
See pages 259-264 for a complete listing
of Frequently Ordered Products
1
Not available with PC, PB or SH option
Product Guide
149
Dusk to Dawn Series DTD
Security Light
150-400W HPS, 175-400W MV/MH
P R O D U C T
O V E R V I E W
Features:
Ballast is completely enclosed in arm, but is readily accessible.
Available in a variety of IES light distribution patterns
All components in single carton.
Refractor available in open-bottom acrylic, or polycarbonate.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Suitable for -30°C MH & MV / -40°C HPS.
Complies with ANSI: C136.2, C136.10
Applications:
Rural areas
Small businesses
Storage lots
DIMENSIONS
17"
(432)
13"
(330)
37"
(940)
Approx. Wt. = 23 lbs.
150
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Dusk to Dawn Series DTD
Security Light
150-400W HPS, 175-400W MV/MH
O R D E R I N G
I N F O R M AT I O N
Example: D T D 1 5 S R H 1 2 0 R 3 B A
Wattage / Source
Series
DTD Dusk to Dawn
15
17
20
23
24
25
31
40
Voltage
Ballast
150 W
S HPS
175 W
V MV
200 W
M MH
250/400W
wired 250W
250/400W
wired 400W
250 W
310 W
400 W
RN
RH
CA
CT
XN
Reactor Normal Power Factor
Reactor High Power Factor
CWA Auto Reg
CWI
High Reactance (Lag) Normal
Power Factor
XH High Reactance (Lag) High
Power Factor
SC SCWA
Refer to the ballast matrix on
page 156 for compatibility.
120
208
220
230
240
277
347
MT1
MT2
MT8
MT7
TT1
TT7
TT3
DT1
120V
208V
220V
230V
240V
277V
347V
Multi-tap wired 120V
Multi-tap wired 240V
Multi-tap wired 208V
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual-tap 120/240
wired 120V
DT2 Dual-tap 120/240
wired 240V
DT3 Dual-tap 240/480
wired 240V
DT4 Dual-tap 240/480
wired 480V
Distribution
R3 Type III
R5 Type V
Optics
BA Open-Bottom
Acrylic
BP Open-Bottom
Polycarbonate
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Standard Listing
(blank) No Listing
CS CSA Certified
Photocontrol
NR No Photocontrol Receptacle1
Lamp
LC
LD
LG
Starter3
SN No Ignitor (use self-igniting lamp)
Misc.
NL
PC
SH
Notes:
NEMA Label
Photocontrol included
per voltage specified
Shorting Cap
1
2
3
Not available with PC or SH option
Requires SN option
HPS only
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Self-Igniting Lamp2
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
151
Series 165
Security Lighting Luminaires - Ballast-In-Arm
50-400W HPS, 175-400W MH, 100-400 MV
P R O D U C T
O V E R V I E W
Features:
NEW
One-piece, die-cast aluminum head and arm configuration for long-life stability
and performance.
Optical assembly utilizes dual latch mounting for quick, easy and secure
installation.
Electrical components mounted to power door for installation and
maintenance convenience.
Gray polyester powder coated housing finish is standard.
Refractors available in open-bottom acrylic, polycarbonate and glass.
NEMA Label standard.
Open board starter standard on HPS units.
Suitable for -30°C MH & MV / -40°C HPS.
Complies with ANSI: C136.2, C136.10, C136.15, C136.6
Applications:
Parking lots
Roadways
Commercial environments
Office communities
DIMENSIONS
13.5"
(343)
12"
(305)
37"
(940)
Approx. Wt. = 35 lbs.
152
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Series 165
Security Lighting Luminaires - Ballast-In-Arm
50-400W HPS, 175-400W MH, 100-400 MV
O R D E R I N G
I N F O R M AT I O N
Example: 1 6 5 1 7 V X H 1 2 0 R 5 B A L C P C
Wattage / Source
Series
165 Ballast in
Arm
05
07
10
15
17
20
23
24
25
31
40
S HPS
M MH
V MV
50W
70W
100W
150W
175W
200W
250/400W
wired 250W
250/400W
wired 400W
250W
310W
400W
Refer to the ballast matrix on
page 156 for compatibility.
RN Reactor Normal
Power Factor
RH Reactor High Power
Factor
XN High Reactance /
Lag Normal
Power Factor
XH High Reactance /
Lag High
Power Factor
CA CWA Auto Reg
CT CWI
SC SCWA
MR Mag Reg
Distribution
Voltage
Ballast
120
208
220
230
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
DT2
DT3
DT4
120V
208V
220V
230V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual-tap 120/240 wired 120V
Dual-tap 120/240 wired 240V
Dual-tap 240/480 wired 240V
Dual-tap 240/480 wired 480V
R1
R2
R3
R4
R5
RX
Area Type I
Area Type II
Area Type III
Area Type IV
Area Type V
Type II 4-way1
Optics
BA Open-Bottom
Acrylic
BP Open-Bottom
Polycarbonate
BG Open-Bottom
Glass2
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Terminal Block
(blank) Hard Wired (standard)
T2 Wired to L1 & L2 Positions3
T3 3-Wire Operation (L1, N, L2
Position)3
TB Terminal Block3
Listing
UL
CS
Fusing4
SF
DF
UL Listing (standard)
CSA Certified
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle
(blank) NEMA Photocontrol Receptacle
(standard)
NR No Photocontrol Receptacle5
Starter
(blank)
EC
Open board (standard)
Encapsulated starter
Lamp
LC
LD
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Misc.
PC
TL
SS
Notes:
1
2
3
4
5
BA or BG optics only
Not available in R4 distribution
Voids UL and CSA listing
Voids UL and CSA listing, not available
with MT, TT and DT voltages
PC option not available with NR option
Photocontrol Included per
Voltage Specified
Tool-less Entry
Stainless Steel Hardware
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
153
Accessories
P
S
Pre-wired to terminal block
Supply wire included in carton
WIRE SIZE AND SPECIFICATION
W I R E
A
B
C
D
E
F
G
H
I
J
K
L
W
M
N
#10 CU Solid B/W
#10 CU Solid B/B
#10 CU Solid B/B/W
#10 CU Stranded B/W
#10 CU Stranded B/B
#10 CU Stranded B/B/W
#12 CU Solid B/W
#12 CU Solid B/B
#12 CU Solid B/B/WD
#12 CU Stranded B/W
#12 CU Stranded B/B
#12 CU Stranded B/B/W
#14 CU Solid B/W
#14 CU Solid B/B
#14 CU Solid B/B/W
LENGTH
P R E - S U P P LY
4
5
6
8
0
4’
5’
6’
8’
10’
Examples
SW5 = 5’ of #14 CU. Solid, B/W wire supplied in carton
PW5 = 5’ of #14 CU. Solid, B/W pre-wired to terminal block
PD0 = 10’ of #10 CU. Stranded, B/W pre-wired to terminal block
154
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
Security Lighting
B A L L A S T
M AT R I C E S
Nema Head 11
Watts
05S
07S
10S
10V
15S
17V
20S
25S
25V
120
RN
RN
RN
XN
RN
XN
XN
XN
XN
208
XN
XN
XN
XN
-
230
RN
RN
RN
-
240
XN
XN
XN
XN
RN
RN
RN
RN
277
XN
XN
XN
XN
XN
RN
-
MT1
XN
XN
XN
XN
-
MT2
XN
XN
XN
XN
-
MT7
XN
XN
XN
XN
-
MT8
XN
XN
XN
XN
-
TT1
XN
XN
XN
XN
-
TT7
XN
XN
XN
XN
-
TT3
XN
XN
XN
XN
-
347
XN
XN
XN
XN
-
Nema Head Package Series 11PKG
Watts
05S
07S
10S
10V
15S
17V
20S
25S
25V
120
RN
RN
RN
XN
RN
XN
XN
XN
XN
208
XN
XN
XN
XN
-
230
RN
RN
RN
-
240
XN
XN
XN
XN
RN
RN
RN
RN
277
XN
XN
XN
XN
XN
RN
-
240
XN
XN
XN
XN
RN
RN
RN
RN
277
XN
XN
XN
XN
XN
RN
-
MT1
XN
XN
XN
XN
-
MT2
XN
XN
XN
XN
-
MT7
XN
XN
XN
XN
-
MT8
XN
XN
XN
XN
-
TT1
XN
XN
XN
XN
-
TT7
XN
XN
XN
XN
-
TT3
XN
XN
XN
XN
-
347
XN
XN
XN
XN
-
Series 11L Package
Watts
05S
07S
10S
10V
15S
17V
20S
25S
25V
120
RN
RN
RN
XN
RN
XN
XN
XN
XN
208
XN
XN
XN
XN
-
230
RN
RN
RN
-
MT1
XN
XN
XN
XN
-
MT2
XN
XN
XN
XN
-
MT7
XN
XN
XN
XN
-
MT8
XN
XN
XN
XN
-
TT1
XN
XN
XN
XN
-
TT7
XN
XN
XN
XN
-
TT3
XN
XN
XN
XN
-
347
XN
XN
XN
XN
-
Series 110
Watts
05S
07S
10S
15S
17V
17M
13S
14S
120
RH, RN
RH, RN, CA
RH, RN, CA
RH, RN
CA, XN, XH
CA
RN, RH
RN, RH
208
X
CA, XH, XN
CA, XH, XN
XN, XH
CA
CA
-
220
RN, RH, XN, XH
RN, RH
-
230
RN, RH
RN, RH
CA
-
240
CA, XN, XH
CA, XN, XH
XN, XH, RN, RH
RH, RN, CA
CA
-
277
CA, XH, XN
CA, XH, XN
XN, XH
RN, RH, CA
CA
-
480
CA
CA
-
DT1
XN, XH
CA, XN, XH
CA, XN, XH
XN, XH
CA
CA
-
DT2
XN, XH
CA, XN, XH
CA, XN, XH
XN, XH
CA
CA
-
MT1
XN, XH
CA, XN, XH
CA, XN, XH
XN, XH
CA
CA
-
MT2
XN, XH
CA, XN, XH
CA, XN, XH
XN, XH
CA
CA
-
Series 110 continued
Watts
05S
07S
10S
15S
17V
17M
13S
14S
MT7
XN, XH
CA, XN, XH
CA, XN, XH
XN, XH
CA
CA
-
MT8
XN, XH
CA, XN, XH
CA, XN, XH
XN, XH
CA
CA
-
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
155
Security Lighting
B A L L A S T
M AT R I C E S
Dusk To Dawn
Watts
15S
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
23/24M
120
RN, RH, CA, CT, MR
XN, XH, CA, CT
CA
CA, CT, XN, XH, MR
XH, XN, CA, CT, MR
CT, CA, XN, XH
CA, CT, SC
CA, MR
CA, CT, XN, XH
CA, CT, XN, XH
CA, CT, SC
CA, CT
CA
208
CA, CT, XN, XH
CA
CA
CA, CT
CA,CT
CA
CA, CT, SC
CA
CA, CT
CA, CT
CA, CT, SC
CA, CT
CA
220
CA
RN, RH
CA
CA
RN, RH
CA
CA
-
230
RN, RH
RN, RH
RN, RH
RN, RH
-
240
277
CA, CT, XN, XH, MR XN, XH, CA
CA, CT, RN, RH
CA, RN
CA
CA
CA, CT, RN, RH, MR CA, CT, MR
RN, RH, CA, CT, MR
CA, CT
RH, RN, CA, CT
CA
CA, CT, SC
CA, SC
CA, MR
CA
RH, RN, CA, CT
CA, CT
CA, CT, XN, XH
CA, CT
CA, CT, SC
CA, SC
CA, CT
CA, CT
CA
CA
480
CA, MR
CA, CT
CA
CA, CT, MR
CA, MR
CA, CT
CA, CT
CA, MR
CA
CT, CA
CA, CT,
CA
CA
DT1
XN, XH, CA, CT, MR
CT, CA
CA
XN, XH, CA, CT, MR
XN, XH, MR
CA, CT
CA, CT, SC
CA, MR
CA, CT, XN, XH
CA, CT, XN, XH
CA, CT
CA, CT
CA
DT2
XN, XH, CA, CT, MR
CT, CA
CA
XN, XH, CA, CT, MR
XN, XH, MR
CA, CT
CA, CT, SC
CA, MR
CA, CT, XN, XH
CA, CT, XN, XH
CA, CT
CA, CT
CA
Dusk To Dawn continued
Watts
15S
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
23/24M
DT3
MR
CT
MR
MR
CT
CT
MR
CT
CT
-
DT4
MR
CT
MR
MR
CT
CT
MR
CT
CT
-
MT1
XN,XH,CA,CT
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
MT2
XN,XH,CA,CT
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
MT7
XN,XH,CA,CT
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
MT8
XN,XH,CA,CT
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
TT1
XN,XH
CA
CA
CA
CA
CA
CA
-
TT7
XN,XH
CA
CA
CA
CA
CA
CA
-
TT3
XN,XH
CA
CA
CA
CA
CA
CA
-
347
XN,XH,CA
CA
CA
CA
CA
CA
CA
CA
-
Series 165
Watts
05S
07S
10S
10V
15S
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
23/24M
120
RH, RN
RH, CA, CT, RN, MR
CA, CT, MR, RH, RN
XH, XN, CA, CT
RN, RH, CA, CT, MR
XN, XH, CA, CT
CA
CA, CT, XN, XH MR
XH, XN, CA, CT
CT, CA, XN, XH
CA, CT, SC
CA, MR
CA, CT, XN, XH
CA, CT, XN, XH
CA, CT, SC
CA, CT
CA
208
XH, XN
XH, CA,CT, XN
XH, CA, CT, XN
CA
CA, CT, XN, XH
CA
CA
CA, CT
CA, CT
CA
CA, CT, SC
CA
CA, CT
CA, CT
CA, CT, SC
CA, CT
CA
220
CA
RN, RH
CA
CA
RN, RH
CA
CA
-
230
RN, RH
RN, RH
RN, RH
RN, RH
RN, RH
-
240
XH, XN
XH, CA, CT, MR, XN
XH, CA, CT, MR, XN
CA, CT
CA, CT, XN, XH, MR
CA, CT, RN, RH
CA
CA, CT, RN, RH, MR
RN, RH, CA, CT
RH, RN, CA,CT
CA, CT, SC
CA, MR
RH, RN, CA, CT
CA, CT, XN, XH
CA, CT, SC
CA, CT
CA
277
XH, XN
XH, CA, XN
CA, XH, XN
XN, XH, CA
XN, XH, CA
CA, RN
CA
CA, CT, MR
CA, CT
CA
CA, SC
CA
CA, CT
CA, CT
CA, SC
CA, CT
CA
480
MR
CA
CT
CA, MR
CA, CT
CA
CA, CT, MR
CA
CA, CT
CA, CT
CA, MR
CA
CT, CA
CA, CT
CA
CA
DT1
XH, XN
XH, XN, CA, CT, MR
CA, CT, XH, MR, XN
CT
XN, XH, CA, CT, MR
CT, CA
CA
XN, XH, CA, CT, MR
XN, XH
CA, CT
CA, CT, SC
CA, MR
CA, CT, XN, XH
CA, CT, XN, XH
CA, CT
CA, CT
CA
Series 165 continued
Watts
05S
07S
10S
10V
15S
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
23/24M
156
DT3
MR
CT
MR
CT
MR
CT
CT
MR
CT
CT
-
DT4
MR
CT
MR
CT
MR
CT
CT
MR
CT
CT
-
Product Guide
MT1
XH,XN
XH,XN,CA
CA,XN,XH
CA
XN,XH,CA,CT
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
MT2
XN,XH
XH,XN,CA,
CA,XN,XH
CA
XN,XH,CA,CT
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
MT7
XN,XH
XH,XN,CA,
CA,XN,XH
CA
XN,XH,CA,CT
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
MT8
XN,XH
XH,XN,CA
CA,XN,XH
CA
XN,XH,CA,CT
CA
CA
CT,CA
CA,CT
CA
CA,SC
CA
CA,CT
CA
CA,SC
CA,CT
CA
TT1
XN,XH
XN,XH
XN,XH
XN,XH
CA
CA
CA
CA
CA
CA
-
TT7
XN,XH
XN,XH
XN,XH
XN,XH
CA
CA
CA
CA
CA
CA
-
For photometric information, visit our website,
www.americanelectriclighting.com
TT3
XN,XH
XN,XH
XN,XH
XN,XH
CA
CA
CA
CA
CA
CA
-
347
XN,XH,CA,CT
XN,XH
XN,XH
XN,XH,CA
CA
CA
CA
CA
CA
CA
CA
-
DT2
XH, XN
XH, XN, CA, CT, MR
CA, CT, MR, XH, XN
CT, CA
XN, XH, CA, CT, MR
CT, CA
CA
XN, XH, CA, CT, MR
XN, XH
CA, CT
CA, CT, SC
CA, MR
CA, CT, XN, XH
CA, CT, XN, XH
CA, CT
CA, CT
CA
AREA LIGHTING
AVL ..........................................................................158
LuxMaster® Luminaire Series 53 ......................160
LuxMaster® Luminaire Series 153 ....................162
LuxMaster® Classic Series LS............................164
LuxMaster® Classic Series LM ..........................166
LuxMaster® Classic Series LL ............................168
LuxMaster® LPS Luminaire Series LML............170
Accessories ..........................................................172
Ballast Matrices....................................................176
American Electric Lighting™
AVL
Area Lighting
250-1000W HPS, 250-1000W MH
P R O D U C T
O V E R V I E W
Features:
Rugged, heavy-gauge aluminum housing is continuously seam welded for
weathertight integrity.
Silicone gasket seals optical compartment from moisture, insects and dust.
Available in multiple mounting options to fit a variety of applications.
Choice of drop or flat lens to allow for full cutoff compliance.
Available in a variety of IES light distributions patterns.
Star Friendly™ cutoff distribution patterns available.
1000W MH designed around reduced jacket lamp.
Tool-less die-cast latching available.
Choice of bolt spacing for mounting arm (4-1/4” or 4-7/8”).
Mogul base, E39 socket standard.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Applications:
Suitable for -30°C MH & MV / -40°C HPS.
Parking lots
Roadways
Commercial environments
Office communities
DIMENSIONS
AVL Drop Glass
AVL Flat Glass
17.5"
(445)
14"
(356)
21.6"
(549)
21.6"
(549)
Effective Projected Area (EPA)
The EPA for the AVL is 2.8 sq. ft.
Approx. Wt = 53 lbs.
158
Product Guide
21.6"
(549)
21.6"
(549)
For photometric information please visit our website:
www.americanelectriclighting.com
AVL
Area Lighting
250-1000W HPS, 250-1000W MH
O R D E R I N G
I N F O R M AT I O N
Example: A V L 1 X M C A M T 7 S M D G S 9
Wattage / Source
Series
AVL American
Vertical
Luminaire
25
31
32
35
40
45
75
1X
250W
310W
320W1
350W1
400W
450W1
750W
1000W1
S HPS
M MH
CA CWA
SC SCWA2
CT CWI
Refer to the ballast matrix on
page 176 for compatibility.
Distribution
Voltage
Ballast
120
208
220
230
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
DT2
DT3
DT4
Optics
Vertical Lamp
120V
AM Asymmetric
208V
SM Symmetric
220V
FV Forward Throw
230V
240V
Horizontal Lamp
277V
R2 Area Type II
347V
R3 Area Type III
480V
FT Forward Throw
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual-tap 120/240 wired 120V
Dual-tap 120/240 wired 240V
Dual-tap 240/480 wired 240V
Dual-tap 240/480 wired 480V
FG Flat Glass Clear
Tempered
DG Drop Glass Clear
Tempered
Refer to Optical Matrix
below.
Mounting3
S9
P9
S2
P2
WP
WB
EF
Square Pole 9” Arm
Round Pole 9” Arm
Square Pole 12” Arm
Round Pole 12” Arm
Wood Pole or Wall 12” Arm
Wall Bracket 12” Arm
External Mast Arm Fitter
Options
Maximum number of options is five, for more options please contact your local
American Electric Lighting representative
Paint4
(blank)
BK
GY
WH
UP
Bronze (standard)
Black
Gray
White
Unpainted
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3-Wire Operation (L1, N, L2
Position)
Listing
UL
CS
UL Listing
CSA Certified
Fusing5
SF
DF
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
NR No Photocontrol Receptacle6
Lamp
LC
LD
Lamp Included, Clear
Lamp Included, Deluxe/Coated
Starter7
(blank) Open Board (standard)
EC Encapsulated Plug-in
OP Open Plug-in
Misc.
A4
PC
TL
SS
5H
NL
SH
TR
Notes:
1
2
3
4-7/8” Hole Spacing on Housing
and Arm
Photocontrol Included per
Voltage Specified
Tool-less Entry
Stainless Steel Fasteners (external)
50 Hertz Ballast Cycle8
NEMA Label on Housing
Shorting Cap
Trigger Latch
4
5
6
7
8
Reduced jacket lamp only
Pulse Start Metal Halide only
Standard arm-hole bolt spacing is 4-1/4”
For 4-7/8” spacing, order “A4” option.
Other colors available; please contact
your local American Electric Lighting
representative
Voids UL/CSA Listing, not available with
MT, TT and DT voltages
PC and SH not available with NR option
HPS only, 400W max
Limited availability; please contact
your local American Electric Lighting
representative
Accessories (shipped separately)
AVLEHS U Field installable external HS shield
universal tenon adapter
AVL Optical Matrix
25S
31S
40S
X1S
25M
32M
35M
40M
75M
X1M
AM FG
◆
◆
◆
◆
◆
◆
◆
◆
SM FG
◆
◆
◆
◆
◆
◆
◆
◆
See pages 259-264 for a complete listing
of Frequently Ordered Products
AM DG
◆
◆
◆
◆
◆
◆
◆
◆
◆
SM DG
◆
◆
◆
◆
◆
◆
◆
◆
◆
FV DG
◆
R2 FG
◆
◆
◆
◆
◆
◆
◆
◆
◆
R3 FG
◆
◆
◆
◆
◆
◆
◆
◆
-
Product Guide
159
LuxMaster® Series 53
Area Lighting
70-150W HPS, 100-175W MV, 175W MH
P R O D U C T
O V E R V I E W
Features:
Durable die-cast aluminum housing for long-life performance.
Optical assembly designed for maximum performance.
Removable ballast tray electrical system for installation and maintenance
ease.
"Breathing Seal" developed by American Electric prevents contaminants from
entering optical assembly for maximum efficiency.
Optics available in flat tempered glass, sag glass, drop acrylic and drop
polycarbonate.
Available in a variety of IES light distributions patterns and cutoff
classifications.
Star Friendly™ cutoff distribution patterns available.
Applications:
Standard product is designed to mount to pipe mast arm. Direct pole mount
arms are available.
Parking lots
Roadways
Residential communities
Commercial environments
Office communities
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Arm ordered separate, see page 175.
UL Listed.
Mogul base, E39, socket standard.
Suitable for -30°C MH & MV / -40°C HPS.
Complies with ANSI: C136.2, C136.10, C136.14, C136.15
DIMENSIONS
13.4"
(340)
23"
(584)
8.25"
(210)
23"
(584)
13.4"
(326)
5.25"
(128)
Effective Projected Area (EPA)
The EPA for the LuxMaster® Series 53 with refractor 1.4 sq. ft.
Approx. Wt = 30 lbs.
160
Product Guide
Effective Projected Area (EPA)
The EPA for the LuxMaster® Series 53 with flat lens is 1.1 sq. ft.
For photometric information please visit our website:
www.americanelectriclighting.com
LuxMaster® Series 53
Area Lighting
70-150W HPS, 100-175W MV, 175W MH
O R D E R I N G
I N F O R M AT I O N
Example: 5 3 1 5 S C A M T 1 R 3 F G L C P C
53 LuxMaster
Shoebox
07
10
15
17
S HPS
M MH
V MV
70W
100W
150W
175W
Voltage
Ballast
Wattage / Source
Series
Refer to the ballast matrix on
page 176 for compatibility.
RN Reactor Normal
Power Factor
RH Reactor High Power
Factor
XN High Reactance /
Lag Normal
Power Factor
XH High Reactance /
Lag High
Power Factor
CA CWA Auto Reg
MR Mag Reg (3 coil)
CT CWI
120
208
220
230
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
DT2
DT3
DT4
Distribution
R2 Roadway Type II
120V
R3 Roadway Type III
208V
220V
Refer to Optical Matrix
230V
below.
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Optics
Multi-tap wired 277V
Tri-tap wired 120V
DA Drop Acrylic
Tri-tap wired 277V
Prismatic Refractor
Tri-tap wired 347V
DP Drop Polycarbonate
Dual-tap 120/240 wired 120V
Prismatic Refractor
Dual-tap 120/240 wired 240V
FG Flat Glass Clear
Dual-tap 240/480 wired 240V
Tempered
Dual-tap 240/480 wired 480V
SG Sag Glass Refractor
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Mounting
(blank) Internal fitter (1-1/4”)
M2 Internal fitter (pre-set 2”)
Paint1
(blank)
BK
GY
WH
Bronze (standard)
Black
Gray
White
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3-Wire Operation (L1, N, L2
Position)
Fusing2
SF
DF
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
NR No Photocontrol Receptacle3
PB Phosphor Bronze Contacts
Lamp
LC
LD
LG
Lamp Included, Clear
Lamp Included, Deluxe
Self-Igniting Lamp4
Starter5
(blank)
EC
OP
PS
SN
Listing
(blank)
CS
Misc.
PC
SS
LA
5H
NL
SH
HK
Notes:
Open Board (standard)
Encapsulated Plug-in
Open Plug-in
Protected/Auto Shutoff6
No Ignitor (using self-igniting lamp)
1
2
3
4
5
6
UL Listed (standard)
CSA Certified
Other colors available; please contact your
local American Electric Lighting representative
Voids UL/CSA Certified Options and not
available in MT, TT and DT voltages
PB, PC and SH not available with NR option
Requires SN option
HPS only
Limited availability; please contact your local
American Electric Lighting representative
Photocontrol Included per
Voltage Specified
Stainless Steel Fasteners (external)
Lightning Arrestor (Void UL/CSA
Listed Options)
50 Hertz Ballast Cycle6
NEMA Label on Housing
Shorting Cap
Hinge Keeper
Series 53 Optical Matrix
05S
07S
10S
15S
17M
17V
R2 DA
◆
◆
◆
◆
-
R3 DA
◆
◆
◆
◆
-
See pages 259-264 for a complete listing
of Frequently Ordered Products
R2 DP
◆
◆
◆
◆
-
R3 DP
◆
◆
◆
◆
-
R2 FG
◆
◆
◆
◆
◆
◆
R3 FG
◆
◆
◆
◆
◆
◆
R2 SG
◆
◆
◆
◆
◆
◆
R3 SG
◆
◆
◆
◆
◆
◆
Product Guide
161
LuxMaster® Luminaire Series 153
Area Lighting
200-400W HPS, 200-400W MV/MH
P R O D U C T
O V E R V I E W
Features:
Die-cast aluminum housing for long-life performance.
Optical assembly designed for maximum performance.
Ballast tray electrical system for installation and maintenance ease.
"Breathing Seal" developed by American Electric preventing contaminants
from entering optical assembly.
Optics available in flat tempered glass, sag glass, drop acrylic and drop
polycarbonate.
Available in a variety of IES light distributions patterns.
Star Friendly™ cutoff distribution patterns available.
Standard product is designed to mount to pipe mast arm. Direct pole mount
arms are available.
Arm ordered separate, see page 175.
Applications:
UL Listed.
Parking lots
Roadways
Residential communities
Commercial environments
Office communities
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Mogul base, 539 socket std.
Suitable for -30°C MH & MV / -40°C HPS.
Complies with ANSI: C136.2, C136.10, C136.14, C136.15
DIMENSIONS
17"
(450)
27.1"
(689)
8.25"
(201)
27.12"
(662)
17"
(432)
8.2"
(209)
Effective Projected Area (EPA)
The EPA for the LuxMaster® HPS Luminaire Series 153 with flat
lens is 2.1 sq. ft.
Approx. Wt = 45 lbs.
162
Product Guide
The EPA for the LuxMaster® HPS Luminaire Series 153 with drop
lens is 2.4 sq. ft.
For photometric information please visit our website:
www.americanelectriclighting.com
LuxMaster® Luminaire Series 153
Area Lighting
200-400W HPS, 200-400W MV/MH
O R D E R I N G
I N F O R M AT I O N
Example: 1 5 3 2 5 S C A M T 1 R 3 F G L C E C P C
Wattage / Source
Series
153 LuxMaster
Shoebox
S HPS
M MH
V MV
20
25
31
40
23
200W
250W
310W
400W
250/400W
wired 250
24 250/400W
wired 400
Refer to the ballast matrix on
page 179 for compatibility.
Distribution
Voltage
Ballast
RN Reactor Normal
Power Factor
RH Reactor High Power
Factor
XN High Reactance /
Lag Normal
Power Factor
XH High Reactance /
Lag High
Power Factor
CA CWA Auto Reg
MR Mag Reg (3 coil)
CT CWI
120
208
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
DT2
DT3
DT4
R2 Roadway Type II
120V
R3 Roadway Type III
208V
240V
Refer to Optical Matrix
277V
below.
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Optics
Multi-tap wired 240V
Multi-tap wired 277V
DA Drop Acrylic
Tri-tap wired 120V
Prismatic Refractor
Tri-tap wired 277V
DP Drop Polycarbonate
Tri-tap wired 347V
Prismatic Refractor
Dual-tap 120/240 wired 120V
FG Flat Glass Clear
Dual-tap 120/240 wired 240V
Tempered
Dual-tap 240/480 wired 240V
SG Sag Glass
Dual-tap 240/480 wired 480V
Prismatic Refractor
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Mounting
(blank) Internal fitter (1-1/4”)
M2 Internal fitter (pre-set 2”)
Paint1
(blank)
BK
GY
WH
Bronze (standard)
Black
Gray
White
Terminal Block
(blank) Terminal Block (standard)
T2 Wired to L1 & L2 Positions
T3 3 Wire Operation (L1, N, L2
Position)
Fusing2
SF
DF
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
NR No Photocontrol Receptacle3
PB Phosphor Bronze Contacts
Lamp
LC
LD
LG
Lamp Included, Clear
Lamp Included, Deluxe
Self Igniting Lamp4
Starter5
(blank)
EC
OP
PS
SN
Listing
(blank)
CS
Misc.
PC
SS
LA
5H
NL
SH
HK
Notes:
Open Board (standard)
Encapsulated Plug-in
Open Plug-in
Protected/Auto Shutoff6
No Ignitor (using self-igniting lamp)
1
2
3
4
5
6
UL Listed (standard)
CSA Certified
Other colors available; please contact your
local American Electric Lighting representative
Voids UL/CSA listing, not available with MT, TT
and DT voltages
PB, PC, and SH not available with NR option
Requires SN option
HPS only
Limited availability; please contact your local
American Electric Lighting representative
Photocontrol Included per
Voltage Specified
Stainless Steel Fasteners (external)
Lightning Arrestor
50 Hertz Ballast Cycle6
NEMA Label on Housing
Shorting Cap
Hinge Keeper
Series 153 Optical Matrix
20S
31S
40S
25M
40M
R2 DA
◆
◆
◆
-
R3 DA
◆
◆
◆
-
R2 DP
◆
◆
◆
-
R3 DP
◆
◆
◆
-
R2 FG
◆
◆*
R3 FG
◆
◆
◆
-
R2 SG
◆
◆
◆
-
R3 SG
◆
◆
◆
◆
◆
* Requires use of ED28 lamp
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
163
LuxMaster® Classic Series LS
Area Lighting
70-150W HPS, 175W MH/MV
P R O D U C T
O V E R V I E W
Features:
Rugged heavy gauge aluminum housing is continuously seam welded for
weathertight integrity.
Multiple mounting options to fit a variety of applications.
Optical assembly designed for maximum performance.
Removable ballast tray electrical system for installation and maintenance
ease.
Mogul base, E39 socket standard.
"Breathing Seal" developed by American Electric prevents contaminants from
entering optical assembly for maximum efficiency.
Tempered flat glass lens standard, drop polycarbonate option available.
Available in a variety of IES full cutoff light distributions patterns.
Star Friendly™ cutoff distribution patterns available.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Applications:
Suitable for -30°C MH & MV / -40°C HPS.
Parking lots
Office complexes
Security lighting
Residential areas
Commercial environments
DIMENSIONS
9"
(229)
15"
(381)
15"
(381)
Effective Projected Area (EPA)
The EPA for the LuxMaster Classic Luminaire, Series LS is 1.75 sq. ft.
Approx. Wt. = 20 lbs.
164
Product Guide
For photometric information please visit our website:
www.americanelectriclighting.com
LuxMaster® Classic Series LS
The following three separate components must be ordered:
1) BALLAST TRAY 2) HOUSING 3) MOUNTING
Area Lighting
70-150W HPS, 175W MH/MV
O R D E R I N G
1) Ballast Tray
Example: L S 1 5 S R H 1 2 0 R 3
Wattage / Source
Series
LS LuxMaster
Shoebox
07
10
15
17
70W
100W
150W
175W
S HPS
M MH
V MV
Distribution
Voltage
Ballast
RN Reactor Normal
Power Factor
RH Reactor High Power
Factor
XN High Reactance /
Lag Normal
Power Factor
XH High Reactance /
Lag High
Power Factor
CA CWA Auto Reg
CT CWI
MR Mag Reg
Refer to the ballast matrix on
page 177 for compatibility.
120
208
220
230
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
DT2
DT3
DT4
120V
208V
220V
230V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual-tap 120/240 wired 120V
Dual-tap 120/240 wired 240V
Dual-tap 240/480 wired 240V
Dual-tap 240/480 wired 480V
O R D E R I N G
2) Housing
Series
LS LuxMaster
Shoebox
R2 Roadway Type II
R3 Roadway Type III
R5 Roadway Type V
Options
Fusing1
SF
DF
Single Fuse
(120, 277, 347V)
Double Fuse
(208, 220, 240, 480V)
Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
NR No Photocontrol
Receptacle2
PB Phosphor Bronze Contacts
I N F O R M AT I O N
Example: L S 1 5 S R 3 H S G P C
Wattage / Source
07
10
15
17
XX
Options
Housing
S HPS
70W
M MH
100W
V MV
150W
175W
No Ballast3
HSG Housing Unit
Distribution
R2 Roadway Type II
R3 Roadway Type III
R5 Roadway Type V
O R D E R I N G
3) Mounting
Paint4
(blank)
BK
GY
WH
Misc.
SS
Bronze (standard)
Black
Gray
White
SH
DP
PC
Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
NR No Photocontrol
Receptacle2
PB Phosphor Bronze Contacts
Example: L M P B Z
Series
Notes:
Paint
Mounting
P
W
K
M
T
1
2
3
Square Pole 12” Arm
Wall Bracket 12” Arm
Adjustable Knuckle
External Fitter
Square Tenon
Square Tenon 2 arms 90°
Square Tenon 2 arms 180°
Square Tenon 3 arms 90°
4
5
6
7
8
9
R
LC
WY
Stainless Steel
Fasteners (external)
Shorting Cap
Drop Polycarbonate5
Photocontrol included per
voltage specified
Lamp Included, Clear
Wraparound Yoke
I N F O R M AT I O N
1
LM LuxMaster
Shoebox
I N F O R M AT I O N
Square Tenon 4 arms 90°
Round Tenon
Round Tenon 2 arms 90°
Round Tenon 2 arms 180°
Round Tenon 3 arms 90°
Round Tenon 3 arms 120°
Round Tenon 4 arms 90°
2
Paint4
BZ Bronze
(standard)
BK Black
GY Gray
WH White
See pages 259-264 for a complete listing
of Frequently Ordered Products
3
4
5
Voids UL/CSA Certified Options and
not available in MT, TT,and
DT voltages
PB, PC and SH not available with
NR option
NL not available
Other colors available; please
contact your local American
Electric Lighting representative
Available in R3 and R5 distributions
Product Guide
165
LuxMaster® Classic Series LM
Area Lighting
200-400M HPS, 250-400W MH/MV
P R O D U C T
O V E R V I E W
Features:
Rugged heavy gauge aluminum housing is continuously seam welded for
weathertight integrity.
Multiple mounting options to fit a variety of applications.
Optical assembly designed for maximum performance.
Removable ballast tray electrical system for installation and maintenance
ease.
Mogul base, E39 socket standard.
"Breathing Seal" developed by American Electric prevents contaminants from
entering optical assembly for maximum efficiency.
Star Friendly™ cutoff distribution patterns available.
Tempered flat glass lens standard, drop polycarbonate option available.
Available in a variety of IES full cutoff light distributions patterns.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Applications:
Office complexes
Parking lots
Residential areas
Commercial environments
Security lighting
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
10"
(254)
19"
(483)
19"
(483)
Effective Projected Area (EPA)
The EPA for the LuxMaster Classic Luminaire, Series LM is 2.36 sq. ft.
Approx. Wt. = 45 lbs.
166
Product Guide
For photometric information please visit our website:
www.americanelectriclighting.com
LuxMaster® Classic Series LM
The following three separate components must be ordered:
1) BALLAST TRAY 2) HOUSING 3) MOUNTING
Area Lighting
200-400M HPS, 250-400W MH/MV
O R D E R I N G
1) Ballast Tray
Example: L M 2 0 S X H 1 2 0 R 3
Wattage / Source
Series
LM LuxMaster
Shoebox
I N F O R M AT I O N
S HPS
M MH
V MV
20 200W
25 250W
40 400W
RN Reactor Normal
Power Factor
RH Reactor High Power
Factor
XN High Reactance /
Lag Normal
Power Factor
XH High Reactance /
Lag High
Power Factor
CA CWA Auto Reg
CT CWI
MR Mag Reg
Refer to the ballast matrix on
page 178 for compatibility.
Distribution
Voltage
Ballast
120
208
220
230
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
DT1
DT2
DT3
DT4
120V
208V
220V
230V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual-tap 120/240 wired 120V
Dual-tap 120/240 wired 240V
Dual-tap 240/480 wired 240V
Dual-tap 240/480 wired 480V
O R D E R I N G
LM LuxMaster
Shoebox
Wattage / Source
Single Fuse
(120, 277, 347V)
DF Double Fuse
(208, 220, 240, 480V)
Terminal Block
(blank) Terminal Block
(standard)
T2 Wired to L1 & L2
Positions
T3 3-Wire Operation
(L1, N, L2 Position)
Photocontrol Receptacle
NR No Photocontrol
Receptacle2
I N F O R M AT I O N
20
25
31
40
200W
250W
310W
400W
Options
Housing
S HPS
M MH
V MV
HSG Housing Unit
Distribution
R2 Roadway Type II
R3 Roadway Type III
R5 Roadway Type V
O R D E R I N G
3) Mounting
Paint3
(blank)
BK
GY
WH
Misc.
PC
Bronze (standard)
Black
Gray
White
SS
Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
PB Phosphor Bronze Contacts
NR No Photocontrol Receptacle2
Example: L M P B Z
Series
Mounting
P
W
K
M
T
1
2
3
Square Pole 12” Arm
Wall Bracket 12” Arm
Adjustable Knuckle
External Fitter
Square Tenon
Square Tenon 2 arms 90°
Square Tenon 2 arms 180°
Square Tenon 3 arms 90°
4
5
6
7
8
9
R
SH
DP
WY
Photocontrol Included per
Voltage Specified
Stainless Steel
Fasteners (external)
Shorting Cap
Drop Polycarbonate4
Wraparound Yoke
I N F O R M AT I O N
Notes:
1
LM LuxMaster
Shoebox
Options
Fusing1
SF
Example: L M 2 0 S R 3 H S G
2) Housing
Series
R2 Roadway Type II
R3 Roadway Type III
R5 Roadway Type V
Square Tenon 4 arms 90°
Round Tenon
Round Tenon 2 arms 90°
Round Tenon 2 arms 180°
Round Tenon 3 arms 90°
Round Tenon 3 arms 120°
Round Tenon 4 arms 90°
Paint
2
Paint3
BZ Bronze
(standard)
BK Black
GY Gray
WH White
3
See pages 259-264 for a complete listing
of Frequently Ordered Products
4
Voids UL/CSA Certified options and
not available in MT, TT, and
DT voltages
PC and SH not available with
NR option
Other colors available; please
contact your local American Electric
Lighting representative
Available in R3 and R5 distributions
Product Guide
167
LuxMaster® Classic Series LL
Area Lighting
1000W HPS/MH
P R O D U C T
O V E R V I E W
Features:
Rugged heavy gauge aluminum housing is continuously seam welded for
weathertight integrity.
Multiple mounting options to fit a variety of applications.
Optical assembly designed for maximum performance.
Removable ballast tray electrical system for installation and maintenance
ease.
"Breathing Seal" developed by American Electric prevents contaminants from
entering optical assembly for maximum efficiency.
Star Friendly™ cutoff distribution patterns available.
Mogul base, E39 socket standard.
Tempered flat glass lens.
Available in Type II and III full cut off classifications.
Applications:
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Parking lots
Residential communities
Commercial environments
Security lighting
Office complexes
Suitable for -30°C MH & MV / -40°C HPS.
DIMENSIONS
25"
(634)
25"
(634)
12"
(305)
Effective Projected Area (EPA)
The EPA for the LuxMaster Classic Luminaire, Series LL is 3.5 sq. ft.
Approx. Wt. = 57 lbs.
168
Product Guide
For photometric information please visit our website:
www.americanelectriclighting.com
LuxMaster® Classic Series LL
The following three separate components must be ordered:
1) BALLAST TRAY 2) HOUSING 3) MOUNTING
Area Lighting
1000W HPS/MH
O R D E R I N G
1) Ballast Tray
Example: L L X 1 M C A M T 1 R 3
Wattage / Source
Series
X1 1000W
LL LuxMaster
Shoebox
I N F O R M AT I O N
S HPS
M MH
CA CWA Auto Reg
CT CWI
RN Reactor Normal
Power Factor
RH Reactor High Power
Factor
XN High Reactance /
Lag Normal
Power Factor
XH High Reactance /
Lag High
Power Factor
Refer to the ballast matrix on
page 178 for compatibility.
Distribution
Voltage
Ballast
120
208
220
230
240
277
347
480
MT1
MT2
MT7
DT1
DT2
120V
208V
220V
230V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 240V
Multi-tap wired 277V
Dual-tap 120/240 wired 120V
Dual-tap 120/240 wired 240V
O R D E R I N G
2) Housing
Options
Fusing1
SF
Single Fuse
(120, 277, 347V)
DF Double Fuse
(208, 220, 240, 480V)
Terminal Block
(blank) Terminal Block
(standard)
T2 Wired to L1 & L2
Positions
T3 3-Wire Operation
(L1, N, L2 Position)
Photocontrol Receptacle
NR No Photocontrol
Receptacle2
PB Phosphor Bronze
Contacts
I N F O R M AT I O N
Example: L L X 1 M R 3 H S G P C
Wattage / Source
Series
LL LuxMaster
Shoebox
R2 Roadway Type II
R3 Roadway Type III
X1 1000W
Options
Housing
S HPS
M MH
HSG Housing Unit
Distribution
R2 Roadway Type II
R3 Roadway Type III
O R D E R I N G
3) Mounting
Paint3
(blank)
BK
GY
WH
Misc.
PC
Bronze (standard)
Black
Gray
White
SS
Photocontrol Receptacle
(blank) NEMA Photocontrol
Receptacle (standard)
NR No Photocontrol Receptacle2
PB Phosphor Bronze Contacts
SH
WY
Photocontrol Included per
Voltage Specified
Stainless Steel
Fasteners (external)
Shorting Cap
Wraparound Yoke
I N F O R M AT I O N
Example: L M P B Z
Notes:
Series
LM LuxMaster
Shoebox
Mounting
P
T
1
2
3
4
Square Pole 12” Arm
Square Tenon
Square Tenon 2 arms 90°
Square Tenon 2 arms 180°
Square Tenon 3 arms 90°
Square Tenon 4 arms 90°
5
6
7
8
9
R
Round Tenon
Round Tenon 2 arms 90°
Round Tenon 2 arms 180°
Round Tenon 3 arms 90°
Round Tenon 3 arms 120°
Round Tenon 4 arms 90°
Paint
1
Paint3
BZ Bronze
(standard)
BK Black
GY Gray
WH White
2
See pages 259-264 for a complete listing
of Frequently Ordered Products
3
Voids UL/CSA Certified options and not
available in MT, TT, and DT voltages
PB, PC and SH not available with
NR option
Other colors available; please
contact your local American Electric
Lighting representative
Product Guide
169
LuxMaster® LPS Series LML
LPS Area Lighting
55-180W LPS
P R O D U C T
O V E R V I E W
Features:
Energy-efficient LPS light source.
Suitable for marine environments.
Three durable formed housings available to accentuate a variety of themes.
Hinged captive bezel secured by captive screws for ease of maintenance.
Star Friendly™ cutoff distribution patterns available.
Mounts to standard 1-1/2" or 2" OD mast arm.
Full perimeter silicone sponge gasket.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Suitable for -30°C MH & MV / -40°C HPS.
Applications:
Roadways
Parking lots
Perimeter lighting
Transportation terminals
Shopping centers
Industrial sites
Designated for intrinsically dark areas, such as those
surrounding observatories and sea turtle habitats
DIMENSIONS
TOP
B
C
SIDE
A
END
A
B
LAMP WATTS
A
B
C
EPA
55-90
8''
143/8''
30''
2.83
135
8''
143/8''
40''
3.78
180
8''
143/8''
531/2''
5.00
Approx. Wt. = 40 lbs.
170
Product Guide
For photometric information please visit our website:
www.americanelectriclighting.com
LuxMaster® LPS Series LML
LPS Area Lighting
55-180W LPS
O R D E R I N G
I N F O R M AT I O N
Example: L M L 0 9 L R H 4 8 0 R 1 F P L C
Wattage / Source
Series
LML Low Pressure
Sodium
LuxMaster
Shoebox
55
09
13
18
55W
90W
135W
180W
L LPS
Refer to the ballast matrix on
page 178 for compatibility.
RH Reactor High Power
Factor
XH High Reactance /
Lag High
Power Factor
Distribution
Voltage
Ballast
120
208
240
277
347
480
DT1
DT2
MT1
MT8
MT2
MT7
TT1
TT7
TT3
120V
208V
240V
277V
347V
480V
Dual-tap 120/240 wired 120V
Dual-tap 120/240 wired 240V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
R1 Roadway Type I
Optics
FP Flat Polycarbonate
Options
Paint1
(blank)
BK
GY
WH
Notes:
Bronze (standard)
Black
Gray
White
1
Other colors available; please contact your
local American Electric Lighting representative
Photocontrol Receptacle
(blank) No Photocontrol Receptacle
PR NEMA Photocontrol Receptacle
Lamp
LC
Lamp Included, Clear
Misc.
NL
NEMA Label on Housing
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
171
Accessories
AVA I L A B I L I T Y
53-1-BZ2
153-1-BZ2
53-1-W-BZ2
153-1-W-BZ2
53-1-BZ-WM2
153-1-BZ-WM2
LMPBZ2
LMWBZ2
LMKBZ2
LMTBZ2
LM1BZ2
LM3BZ2
LM4BZ2
LM5BZ2
LM6BZ2
LM7BZ2
LM8BZ2
LM9BZ2
LM0BZ2
LMMBZ2
9401-H2
53-VS1
LS-HS2
LM-HS2
TMS-20-1902
TMS-25-1902
TMS-30-1902
TMS-20-2902
TMS-25-2902
TMS-30-2902
TMS-20-3902
TMS-25-3902
TMS-30-3902
TMS-20-4902
TMS-25-4902
TMS-30-4902
AVL-HS2
53
◆
◆
◆
◆
◆
-
153
◆
◆
◆
◆
-
AVL
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
LS
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
-
LM
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
-
LL
◆
◆
◆
-
Notes:
1 Use with flat lens only
2 Standard finish is Dark Bronze; contact
American Electric Lighting for other finishes
Pole Top Tenon Adapter For AVL
Tenon ID
2.378”
2.875
3.5”
4”
172
Product Guide
Standard 4-1/4” Mounting Pattern
2@180
3@120
4@90
TMS-20-280 TMS-20-320 TMS-20-490
TMS-25-280 TMS-25-320 TMS-25-490
TMS-35-280 TMS-35-320 TMS-35-490
TMS-30-280 TMS-30-320 TMS-30-490
Optional 4-7/8” Mounting Pattern
2@180
3@120
4@90
T47-20-280 T47-20-320 T47-20-490
T47-25-280 T47-25-320 T47-25-490
T47-35-280 T47-35-320 T47-35-490
T47-30-280 T47-30-320 T47-30-490
For more information please visit our website:
www.americanelectriclighting.com
Accessories
Mounting Hardware
O R D E R I N G
Catalog
Number
Item
9920-H
Universal Wall Mount
Designed for aluminum and steel with universal adjustment
of 180° for yoke mounting.
Furnished with all hardware except wall mounting bolts.
D ATA
Approx.
Wt. (lbs)
1
Area Rectilinear Arm
Field Installed
53-1-BZ
153-1-BZ
A
B
C
D
2.031”
2.781” 3.25”
8”
2.031”
3.531”
4”
10”
NOTE: Pole must be drilled to match dimensions shown.
32
46
Area Wall Mount Bracket
53-1-W-BZ
153-1-W-BZ
53-1-BZ-WM
153-1-BZ-WM
53-VS
A
B
C
D
5.687”
4.687” 2.781” 2.031”
5.687”
4.687” 3.531” 2.031”
NOTE: Pole must be drilled to match dimensions shown.
Pole Mount Plate
Pole mount comes with rectilinear arm.
Polycarbonate Shield
For flat lens only.
See pages 259-264 for a complete listing
of Frequently Ordered Products
32
46
Series 53
Series 153
7
5
Series 53
5
Product Guide
173
Accessories
Steel Bracket - Prime Coated
(For Horizontally Mounted Luminaires)
M O U N T I N G
Catalog
Number
9401
O P T I O N S
Item
FABRICATED STEEL BRACKET — SINGLE ARM
For mounting on 2'' (23/8'' OD) standard pipe or pole
top tenon. 12'' spread.
Effective
Projected
Area (Sq. Ft.)
Approx.
Wt. (lbs.)
.4
10
See Isotach Wind Map, page 215
Note: Above brackets available with Galvanized Finish. To order add G suffix to catalog number.
174
Product Guide
For photometric information please visit our website:
www.americanelectriclighting.com
Accessories
M
M OO UU NN TT II NN GG OO PP TT II OO NN SS
12''
Pole mount, secured with solid steel
plate, attaches luminaire directly to
square pole. Full length mounting screws
secure luminaire, arm and pole.
Square/round tenon adapter mounts
on top of round or square pole for
luminaire attachment. Makes a
smooth transition from pole to
luminaire. Available mounting
arrangements listed below.
Catalog Number - LMPBZ
Wall mount arm secures luminaire to wall
plate with full length mount screws. Full
length mounting screws secure luminaire
to arm and wall plate.
Catalog Numbers
LM5BZ Square
LMTBZ Round
12''
Catalog Number - LMWBZ
Adjustable knuckle for pole attachment
of luminaire. Makes a smooth transition
from pole to luminaire.
36''
9-3/4''
Wraparound Yoke - Luminaire is
suspended above mounting surface
by mount and extends above poles.
273/8''
Catalog Constructable Option
Catalog Number - LMKBZ
Catalog Number
LMTBZ
LM1BZ
LM2BZ
LM3BZ
LM4BZ
LM5BZ
LM6BZ
LM7BZ
LM8BZ
LM9BZ
LMRBZ
Description
Square Tenon with 1 Arm
Square Tenon with 2 Arms at 90°
Square Tenon with 2 Arms at 180°
Square Tenon with 3 Arms
Square Tenon with 4 Arms
Round Tenon with 1 Arm
Round Tenon with 2 Arms at 90°
Round Tenon with 2 Arms at 180°
Round Tenon with 3 Arms at 90°
Round Tenon with 3 Arms at 120°
Round Tenon with 4 Arms at 90°
Mast arm mount - Luminaire is
attached to curved mast arm for
mounting to pole or structure.
3-5/8''
Catalog Number - LMMBZ
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
175
Area Lighting
B A L L A S T
M AT R I C E S
AVL
Watts
25S
25V
25M
31S
32M
35M
40S
40M
45M
75M
XS
XM
120
CA
CA
CA, SC
CA
SC
SC
CA
CA, SC
SC
SC
CA
CA, SC
208
CA
CA
CA, SC
CA
SC
SC
CA
CA, SC
SC
SC
CA, CT
CA, SC
220
CA
CA
SC
CA
CA
CA, CT
-
230
CA
CA, SC
-
240
CA
CA
CA, SC
CA
SC
SC
CA
CA, SC
SC
SC
277
CA
CA
CA, SC
CA
SC
SC
CA
CA, SC
SC
SC
CA
CA, SC, CT
480
CA
CA
CA
CA
SC
SC
CA
CA, SC
SC
SC
CA
SC
DT1
CA, CT
CA
SC
CA
SC
SC
CA
CA, SC
SC
CA
CA
DT2
CA, CT
CA
SC
CA
SC
SC
CA
CA, SC
SC
CA
CA
DT3
CT
-
DT4
CT
-
AVL continued
Watts
25S
25V
25M
31S
32M
35M
40S
40M
45M
75M
XS
XM
MT1
CA
CA
CA, SC
CA
SC
SC
CA
CA, SC
SC
CA
CA, SC
MT2
CA
CA
CA, SC
CA
SC
SC
CA
CA, SC
SC
CA
CA, SC
MT7
CA
CA
CA, SC
CA
SC
SC
CA
CA, SC
SC
CA
CA, SC
MT8
CA
CA
CA, SC
CA
SC
SC
CA
CA, SC
SC
CA
CA, SC
TT1
CA
CA
SC
SC
SC
CA, CT
CA, SC, CT
SC
CA
CA
TT3
CA
CA
SC
SC
SC
CA, CT
CA, SC, CT
SC
CA
CA
208
XH, CA, CT, XN
XH, CA, CT, XN
CA, CT, XN, XH
CA
CA
220
CA
-
230
RN, RH
RN, RH
-
240
XH, CA, CT, MR, XN
XH, CA, CT, MR, XN
CA, CT, XN, XH
CA, CT, RN, RH
CA
277
XH, CA, XN
CA, XH, XN
XN, XH, CA
CA
CA
TT7
CA
CA
SC
SC
SC
CA, CT
CA, SC, CT
SC
CA
CA
347
CA, CT
CA
SC
SC
SC
CA, CT
CA, SC,CT
SC
SC
CA
CA, CT
LuxMaster® Series 53
Watts
07S
10S
15S
17V
17M
120
RH, CA, CT, RN, MR
CA, CT, MR, RH, RN
RN, RH, CA, CT
XN, XH, CA, CT
CA
480
DT1
DT2
MR XH, XN, CA, CT, MR XH, XN, CA, CT, MR
CA CA, CT, XH, MR, XN CA, CT, MR, XH, XN
CA
XN,XH, CA, CT
XN, XH, CA, CT
CA,CT
CT
CT, CA
CA
CA
CA
LuxMaster® Series 53 continued
Watts
07S
10S
15S
17V
17M
176
MT1
XH, XN, CA
CA, XN, XH
XN, XH, CA
CA
CA
Product Guide
MT2
XH, XN, CA,
CA, XN, XH
XN, XH, CA
CA
CA
MT7
XH, XN, CA
CA, XN, XH
XN, XH, CA
CA
CA
MT8
XH, XN, CA
CA, XN, XH
XN, XH, CA
CA
CA
TT1
XN, XH
XN, XH
XN, XH
-
TT7
XN, XH
XN, XH
XN, XH
-
TT3
XN, XH
XN, XH
XN, XH
-
347
XN, XH,CA,CT
XN, XH
XN, XH, CA
-
For photometric information please visit our website:
www.americanelectriclighting.com
DT3
MR
CT
-
DT4
MR
CT
-
Area Lighting
B A L L A S T
M AT R I C E S
LuxMaster® Series 153
Watts
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
120
XH, CA, CT, MR, XN
XN, CA, CT, MR, XH
XH, XN, CA
CA
MR
XN, CA, CT, MR, XH
XH, XN, CA
CA
CA
208
CA, CT
CA, CT
CA
CA
CA, CT
CA
CA
CA
240
RN, RH, CA, CT, MR
RH, RN, CA, CT, MR
RH, RN
CA
MR
RH, RN, CA, CT, MR
CA
CA
CA
277
CA, CT
CA, CT
CA
CA
CA, CT
CA
CA
CA
347
CA
CT
CA
-
480
CA, CT, MR
CA, CT, MR
CA
MR
CA, CT, MR
CA
CA
DT1
XH, XN, CA, CT, MR
XH, XN, CA, CT, MR
CA
CA
MR
CA, CT, MR
CA
CA
CA
DT2
XH,XN,CA,CT,MR
XH,XN,CA,CT,MR
CA
CA
MR
CA,CT,MR
CA
CA
CA
DT3
MR
MR
CA
MR
MR
CA
-
DT4
MR
MR
CA
MR
MR
CA
-
LuxMaster® Series 153 continued
Watts
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
MT1
CA, CT
CA, CT
CA
CA
CA, CT
CA
CA
CA
MT2
CA, CT
CA, CT
CA
CA
CA, CT
CA
CA
CA
MT7
CA, CT
CA, CT
CA
CA
CA, CT
CA
CA
CA
MT8
CA, CT
CA, CT
CA
CA
CA, CT
CA
CA
CA
TT1
CA
CA
CA
CA
-
TT7
CA
CA
CA
CA
-
TT3
CA
CA
CA
CA
-
LuxMaster® Classic Series LS
Watts
07S
10S
10V
15S
17V
17M
120
RH,CA,CT,RN,MR
CA,CT,MR,RH,RN
XH,XN,CA,CT
RN,RH,CA,CT
XN,XH,CA,CT
CA
208
XH,CA,CT,XN
XH,CA,CT,XN
CA
CA,CT,XN,XH
CA
CA
220
CA
-
230
RN,RH
RN,RH
-
240
XH,CA,CT,MR,XN
XH,CA,CT,MR,XN
CA,CT
RN,RH,CA,CT,XN,XH
CA,CT,RN,RH
CA
277
XH,CA,XN
CA,XH,XN
XN,XH,CA
XN,XH,CA
CA
CA
480
MR
CA
CT
CA
CA,CT
CA
DT1
XH,XN,CA,CT,MR
CA,CT,XH,MR,XN
CT
XN,XH,CA,CT
CT
CA
DT2
XH,XN,CA,CT,MR
CA,CT,MR,XH,XN
CT,CA
XN,XH,CA,CT
CT,CA
CA
DT3
MR
CT
CT
-
DT4
MR
CT
CT
-
LuxMaster® Classic Series LS continued
Watts
07S
10S
10V
15S
17V
17M
MT1
XH, XN, CA
CA, XN, XH
CA
XN, XH, CA
CA
CA
MT2
XH, XN, CA
CA, XN, XH
CA
XN, XH, CA
CA
CA
MT7
XH, XN, CA
CA, XN, XH
CA
XN, XH, CA
CA
CA
MT8
XH, XN, CA
CA, XN, XH
CA
XN, XH, CA
CA
CA
TT1
XN, XH
XN, XH
XN, XH
XN, XH
-
TT7
XN, XH
XN, XH
XN, XH
XN, XH
-
TT3
XN, XH
XN, XH
XN, XH
XN, XH
-
347
XN, XH, CA, CT
XN, XH
XN, XH
XN, XH, CA
-
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
177
Area Lighting
B A L L A S T
M AT R I C E S
LuxMaster® Classic Series LM
Watts
20S
25S
25V
25M
40S
40V
40M
120
CA,CT,XN,XH
CA,CT,XN,XH
XN,XH,CA,CT
CA,CT
XH,XN,CA,CT,MR
XH,XN
CA,CT
208
CA,CT
CA,CT
CA
CA
CA,CT,MR
CA,CT
CA,CT
220
RH,CA,CT
RH,,RN
-
230
RN,RH
RH,RN,CA,CT,MR
RH,RN,CA,CT,
CA,CT,
240
RN,RH,CA,CT,XN,XH
RN,RH,CA,CT
RN,RH,CA,CT
CA,CT
MR,CA,CT
RH,CA,CT,RN
CA,CT
277
CA,CT
CA,CT
CA
CA
CA,CT
CA,CT
480
CA,CT
CA,CT
CA,CT
CA,CT
CA,CT,MR
CA,CT,
DT1
CA,CT,XN,XH
XN,XH,CA,CT
CA,CT
CA,CT
CA,CT,MR
CA,CT
CA,CT
DT2
CA,CT,XN,XH
XN,XH,CA,CT
CA,CT
CA,CT
CA,CT,MR
CA,CT
CA,CT
LuxMaster® Classic Series LM continued
Watts
20S
25S
25V
25M
40S
40V
40M
DT3
CT
CT
MR
CA, CT
-
DT4
CT
CT
MR
CA, CT
-
MT1
CA, CT
CA, CT
CA
CA
CA, CT, MR, RH, RN, XN, XH
CA, CT, XN, XH, RN, RH
CA, CT, XN, XH, RN, RH
MT2
CA, CT
CA, CT
CA
CA
CA, CT, MR, RH, RN, XN, XH
CA, CT, XN, XH, RN, RH
CA, CT, XN, XH, RN, RH
MT7
CA, CT
CA, CT
CA
CA
CA, CT, MR, RH, RN, XN, XH
CA, CT, XN, XH, RN, RH
CA, CT, XN, XH, RN, RH
MT8
TT1
CA,CT
CA
CA,CT
CA, CT
CA
CA
CA
CA, CT, MR, RH, RN, XN, XH
CA, CT, XN, XH, RN, RH
CA, CT, XN, XH, RN, RH
-
TT7
CA
CA, CT
CA
-
TT3
CA
CA, CT
CA
-
LuxMaster® Classic Series LL
Watts
XS
XM
120
CA, CT
CA, CT
208
CA, CT
CA, CT
230
CA, CT
CA, CT
240
CA, CT
CA, CT
277
CA, CT
CA, CT
480
CA, CT
CA, CT
DT1
CA, CT
CA, CT
DT4
CA, CT, XN, XH, RN, RH
CA, CT, XN, XH, RN, RH
MT1
CA, CT, XN, XH, RN, RH
CA, CT, XN, XH, RN, RH
MT2
CA, CT, XN, XH, RN, RH
CA, CT, XN, XH, RN, RH
LuxMaster® LPS Luminaire Series LML
Watts
55L
09L
13L
18L
178
120
XH
XH
XH
XH
208
XH
XH
XH
XH
240
XH
XH
XH
XH
Product Guide
277
XH
XH
XH
XH
480
RH
XH
DT1
XH
XH
XH
XH
DT2
XH
XH
XH
XH
MT1
XH
XH
XH
XH
MT2
XH
XH
XH
XH
MT7
XH
XH
XH
XH
MT8
XH
XH
XH
XH
TT1
XH
XH
TT3
XH
XH
TT7
XH
XH
347
XH
XH
For photometric information please visit our website:
www.americanelectriclighting.com
MT7
CA ,CT, XN, XH, RN, RH
CA, CT, XN, XH, RN, RH
347
CA
CA, CT
CA
CA
-
FLOODLIGHTING
Compact Flood Series 51 . . . . . . . . . . . . . . . . . .180
UltraFlood™ Series 75 . . . . . . . . . . . . . . . . . . . .182
UltraFlood™ Series 77 . . . . . . . . . . . . . . . . . . . . .184
Quartz Flood Series 570 . . . . . . . . . . . . . . . . . . .186
Quartz Flood Series 474 . . . . . . . . . . . . . . . . . . .187
AmeriSport™ Series ASP . . . . . . . . . . . . . . . . .188
Sportslighting Series SPF . . . . . . . . . . . . . . . . .190
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192
Ballast Matrices . . . . . . . . . . . . . . . . . . . . . . . . . .197
American Electric Lighting™
Compact Flood Series 51
Heavy Duty Floodlight
50-400W HPS, 175-400W MH, 100-400W MV, 250/400 Dual-Watt HPS/MH
P R O D U C T
O V E R V I E W
Features:
Compact design for an unobtrusive presence in the environment.
Wide NEMA beam patterns available with horizontal lamp.
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance.
Single door access to lamp and electrical components for quick, easy
installation and servicing.
Pivoting painted yoke is standard; tenon, galvanized and painted wraparound
yoke mounting options are available for precise aiming.
UL listing is standard.
For easy maintenance, tool-less entry is available.
Lens is thermal shock and impact resistant tempered glass.
Hydroformed reflector.
Applications:
Auto dealerships
Schools
Construction sites
Recreational areas
Storage yards
Office buildings
Airports
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Churches
Industrial sites
Shopping centers
Parking lots
Substations
Building facades
Suitable for -30°C MH & MV / -40°C HPS.
Note: ED28 lamp must be used with 400W Metal Halide and Mercury Vapor
luminaires.
DIMENSIONS
15.5"
(394)
6"
(152)
17"
(432)
16.25"
(413)
6"
(152)
17"
(432)
15.5"
(394)
6"
(152)
22.5"
(572)
Effective Projected Area (EPA)
The EPA for the Compact flood Series 51 is 1.9 sq. ft
Approx. Wt. = 30 lbs.
180
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Compact Flood Series 51
Heavy-Duty Floodlight
50-400W HPS, 175-400W MH, 100-400W MV, 250/400 Dual-Watt HPS/MH
O R D E R I N G
I N F O R M AT I O N
Example: 5 1 4 0 S C A M T 1 7 6 W Y 0 6 4 3
Wattage / Source
Series
51 Compact Flood
05
07
10
13
14
15
17
20
25
31
40
23
24
S HPS
M MH
V MV
50W
70W
100W
100/150W
wired 100W
100/150W
wired 150W
150W
175W
200W
250W
310W
400W1
250/400W1
wired 250W
250/400W1
wired 400W
120
208
220
240
277
347
480
MT1
MT2
MT8
MT7
TT1
TT7
TT3
DT1
120V
208V
220V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 240V
Multi-tap wired 208V
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual Tap 120/240
wired 120
DT2 Dual-tap 120/240
wired 240
DT3 Dual-tap 240/480
wired 240
DT4 Dual-tap 240/480
wired 480
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA (Auto Reg)
CT CWI
SC SCWA
MR Mag Reg (3 Coil)
Refer to the ballast matrix on
page 197 for compatibility.
Options
Maximum number of options is eight, for more options please contact your local
American Electric Lighting representative
Starter7
Mounting
(blank) Open Board (standard)
(blank) Yoke Mount2
EC Encapsulated Plug-In
TM Tenon Slipfitter2
OP Open Board Plug-In
WY Wraparound Yoke2
SN No Ignitor (using self-igniting lamp)
GW Galvanized Wraparound Yoke
Paint3
(blank)
BK
GY
WH
Bronze (standard)
Black
Gray
White
Terminal Block4
(blank) Hard Wired (standard)
TB Terminal Block
T2 Wired to L1 and L2
T3 3-Wire Operation
(L1, N, L2 positions)
Listing
(blank)
CS
XL
UL Listed (standard)
CSA Certified
No Listing
Photocontrol Receptacle (NEMA twist-lock)
(blank) Photocontrol Receptacle
NR No Photocontrol Receptacle5
PB Phosphor Bronze Contacts
Lamp
LC
LD
LG
Lamp Included, Clear
Lamp Included, Deluxe
Self-Igniting Lamp6
Fusing8
SF
DF
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Cord Length**
04 4’
05 5’
06 6’
08 8’
10 10’
12 12’
15 15’
20 20’
25 25’
30 30’
Misc.
PC
VS
SS
5H
NL
TL
PGS
GS
SH
Cord Type**
63 16-3
44 14-49
43 14-3
23 12-3
NEMA Beam Pattern
Voltage
Ballast
Horizontal Lamp
76 7H x 6V
77 7H x 7V
Refer to Optic
Distribution Matrix
below for compatibility.
Notes:
1 400 MH requires ED28 reduced-jacket lamp
2 Painted to match fixture
3 Other colors available; please contact your local
American Electric Lighting representative
4 Voids UL, CSA listings
5 PB,PC and SH not available with NR option
6 Requires SN options
7 HPS only
8 Voids UL and CSA listing, not available in MT, TT and DT
voltage options
9 For 3-wire operation and ground
10 Limited availability; please contact your local American
Electric Lighting representative
11 Ships separately
**Cord length and type should
be combined to form one
number. Ex: 0643
Photocontrol Included per
Voltage Specified
Vandal Shield7
Stainless Steel (external)
50 Hertz Ballast Frequency10
NEMA Label
Tool-less Entry
Ballistic Shield
Glare Shield11
Shorting Cap
Optic Distribution
15S
20S
31S
40S
17M
25M
40M
77
◆
◆
◆
◆
◆
◆
◆1
76
◆
◆
◆
◆
◆
◆1
Notes:
1 Use ED28 lamp only
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
181
UltraFlood™ Series 75
Heavy Duty Floodlight
100-400W HPS; 100-400W MV; 175/400W MV; 250/400 Dual-Watt HPS/MH
P R O D U C T
O V E R V I E W
Features:
NEMA beam patterns available in a variety of options including horizontal
and vertical lamps.
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance.
Door is hinged and easily removable for quick maintenance.
Fully pivoting painted yoke is standard, tenon and galvanized yoke mounting
options are available for precise aiming.
UL listing is standard.
For easy of maintenance, tool-less entry and ballast tray are available options.
Lens is thermal shock and impact resistant tempered glass.
Hydroformed reflector.
Suitable for -30°C MH & MV / -40°C HPS.
Applications:
Auto dealerships
Schools
Construction sites
Recreational areas
Storage yards
Office buildings
Airports
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Churches
Industrial sites
Shopping centers
Parking lots
Substations
Building facades
DIMENSIONS
17.75"
(451)
7.00"
(178)
23.00"
(584)
1.00" (25)
2.00" (51)
19.50"
(495)
17.75"
(451)
2.00"
(51)
.44" (11) Dia.
.78" (20) Dia.
7.00"
(178)
1.00" (25)
2.00" (51)
21.13"
(537)
19.50"
(495)
Effective Projected Area (EPA)
The EPA for the UltraFlood™ Series 75
is 2.75 sq. ft.
Approx. Wt. = 37 lbs.
182
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
UltraFlood™ Series 75
Heavy-Duty Floodlight
100-400W HPS; 100-400W MV; 175/400W MV; 250/400 Dual-Watt HPS/MH
O R D E R I N G
I N F O R M AT I O N
Example: 7 5 4 0 M C A M T 1 6 6 0 6 4 3 L C T L P C
Series
75 UltraFlood
Wattage / Source
10
15
17
20
25
31
40
23
100W
150W
175W
200W
250W
310W
400W
250/400W
wired 250W
24 250/400W
wired 400W
S HPS
M MH
V MV
RN Reactor Normal
Power Factor
RH Reactor High
Power Factor
XN High Reactance
(Lag) Normal
Power Factor
XH High Reactance
(Lag) High
Power Factor
CA CWA (Auto Reg)
CT CWI
SC SCWA
MR Mag Reg (3 Coil)
Refer to the ballast matrix on
page 198 for compatibility.
Options
Maximum number of options is eight, for more options please contact your local
American Electric Lighting representative
Mounting
(blank) Yoke Mount (standard)1
YG Wraparound Yoke Galvanized
TM Tenon Slipfitter1
Lamp
LC
LD
LG
Lamp Included, Clear
Lamp Included, Deluxe
Self-Igniting Lamp6
Paint2
(blank)
BK
GY
WH
Fusing7
SF
DF
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Bronze (standard)
Black
Gray
White
Terminal Block3
(blank) Hard Wired (standard)
TB Terminal Block Factory Wire
T2 Wired to L1 and L2 Position
T3 3-Wire Operation
(L1, N, L2 Position)
Listing
(blank)
CS
XL
UL Listed (standard)
CSA Certified
No Listing
Photocontrol Receptacle
(blank) Photocontrol Receptacle (standard)
NR No Photocontrol Receptacle
PB Phosphor Bronze Contacts4
Starter5
(blank)
EC
OP
SN
Open Board (standard)
Encapsulated Plug-In
Open Board Plug-In
No Ignitor (using self-igniting lamp)
PP
SS
5H
NL
PGS
WG
VS
SH
Vertical Lamp
76 7H - 6V
66 6H - 6V
Horizontal Lamp
H6 6H - 6V
120
208
220
240
277
347
480
MT1
MT2
MT8
MT7
TT1
TT7
TT3
DT1
120V
208V
220V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 240V
Multi-tap wired 208V
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual-tap 120/240
wired 120V
DT2 Dual-tap 120/240
wired 240V
DT3 Dual-tap 240/480
wired 240V
DT4 Dual-tap 240/480
wired 480V
Refer to Optic
Distribution Matrix below
for compatibility.
Notes:
Cord Length*
04
4’
05
5’
06
6’
08
8’
10
10’
12
12’
15
15’
20
20’
25
25’
30
30’
Misc.
TL
PC
NEMA Beam Pattern
Voltage
Ballast
Cord Type*
63 16-3
44 14-48
43 14-3
23 12-3
*Cord length and type should
be combined to form one
number. Ex: 0423
1 Painted to match fixture
2 Other colors available, please contact your local
American Electric Lighting representative
3 Voids UL and CSA Listing
4 PB, PC, and SH not available with NR option
5 HPS only
6 Requires SN option
7 Voids UL and CSA listing, not available in MT, TT, and DT
voltages
8 For 3-wire operation and ground
9 Limited availability, please contact your local
American Electric Lighting representative
10 Ships separately
Optic Distribution
Tool-less Entry
Photocontrol Included per
Voltage Specified
Removable Power Pad
Stainless Steel Fastener (external)
50 Hertz Ballast Frequency9
NEMA Label
Ballistic Shield10
Wire Guard10
Vandal Shield10
Shorting Cap
See pages 259-264 for a complete listing
of Frequently Ordered Products
20S
25S
40S
17M
25M
40M
17V
25V
40V
76
◆
◆
◆
◆
◆
◆
◆
◆
◆
66
-
◆
◆
◆
◆
◆
◆
56
◆
◆
◆
-
H6
◆
◆
◆
◆
◆
◆
◆
◆
◆
Product Guide
183
UltraFlood™ Series 77
Heavy-Duty Floodlight
400-1000W HPS; 400-1000W MH/MV
P R O D U C T
O V E R V I E W
Features:
NEMA beam patterns available in a variety of options with horizontal lamp.
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance.
Door is hinged and easily removable for quick maintenance.
Fully pivoting painted yoke is standard, tenon and galvanized yoke mounting
options are available for precise aiming.
UL listing is standard.
For easy maintenance, tool-less entry is available.
Suitable for -30°C MH & MV / -40°C HPS.
Lens is thermal-, shock- and impact-resistant tempered glass.
All electrical components warranted by American Electric Lighting's 6-year
guarantee.
Applications:
Churches
Industrial sites
Shopping centers
Parking lots
Substations
Building facades
Auto dealerships
Schools
Construction sites
Recreational areas
Storage yards
Office Buildings
Airports
DIMENSIONS
8-5/8"
(219)
21-7/16"
(545)
21-7/16"
(545)
13"
(330)
23-7/16"
(595)
Front View, Yoke Mount
5-1/2"
(140)
Side View, Tenon Mount
2"
(51)
2"
(51)
7/16"
(11) Dia.
25/32"
(20) Dia.
Hole Spacing, Yoke Mount
Effective Projected Area (EPA)
The EPA for the UltraFlood™ Series 77 is 3.97 sq. ft.
Approx. Wt. = 65 lbs.
184
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
UltraFlood™ Series 77
Heavy-Duty Floodlight
400-1000W HPS; 400-1000W MH/MV
O R D E R I N G
I N F O R M AT I O N
Example: 7 7 X I M C A M T 7 7 6 T M
Wattage / Source
Series
77 UltraFlood
40 400W
S HPS
75 750W
M MH
X1 1000W
V MV
Refer to the ballast matrix on
page 198 for compatibility.
CA
CT
SC
MR
RN
RH
XN
XH
CWA (Auto Reg)
CWI
SCWA (Pulse Start)
Mag Reg
CWA (Auto Reg)
CWI
SCWA (Pulse Start)
Mag Reg
Options
Maximum number of options is eight, for more options please contact your local
American Electric Lighting representative
Mounting
(blank) Yoke Mount (standard)1
YG Yoke Galvanized
TM Tenon Slipfitter1
Paint2
(blank)
BK
GY
WH
Bronze (standard)
Black
Gray
White
Terminal Block3
(blank) Hard Wired (standard)
TB Terminal Block
T2 Wired to L1 and L2
T3 3-Wire Operation
(L1, N, L2 Position)
Listing
(blank)
CS
XL
UL Listed (standard)
CSA Certified
No Listing
Photocontrol Receptacle
(blank) Photocontrol Receptacle
NR No Photocontrol Receptacle4
PB Phosphor Bronze Contacts
Lamp
LC
LD
Fusing5
SF
DF
SS
5H
NL
PGS
WG
VS
SH
NEMA Beam Pattern
120
208
220
240
277
347
480
MT1
MT2
MT8
MT7
TT1
TT7
TT3
DT1
120V
208V
220V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 240V
Multi-tap wired 208V
Multi-tap wired 277V
Tri-tap wired 120V
Tri-tap wired 277V
Tri-tap wired 347V
Dual-tap 120/240
wired 120
DT2 Dual-tap 120/240
wired 240
DT3 Dual-tap 240/480
wired 240V
DT4 Dual-tap 240/480
wired 480V
Horizontal Lamp
65 6H - 5V
66 6H - 6V
76 7H - 6V
Refer to Optic
Distribution Matrix
below for compatibility.
Notes:
Single Fuse (120, 277, 347V)
Double Fuse (208, 220, 240, 480V)
Cord Length*
04 4’
05 5’
06 6’
08 8’
10 10’
12 12’
15 15’
20 20’
25 25’
30 30’
Misc.
TL
PC
Voltage
Ballast
1 Painted to match fixture
2 Other colors available; please contact your local
American Electric Lighting representative
3 Voids UL and CSA certification
4 PB, PC and SH not available with NR option
5 Voids UL and CSA listing; not available in MT, TT and
DT voltages
6 For 3-wire operation and ground
7 Limited availability, please contact your local
American Electric Lighting representative
8 Ships separately
Cord Type*
63
16-3
44
14-46
43
14-3
23
12-3
PW
Pre-wire (Slipfitter only)
*Cord length and type should
be combined to form one
number. Ex: 0643
Optic Distribution
Tool-less Entry
Photocontrol Included per
Voltage Specified
Stainless Steel fasteners (external)
50 Hertz Ballast Frequency7
NEMA Label
Ballistic Shield8
Wire Guard8
Vandal Shield8
Shorting Cap
X1S
X1M
65
◆
66
◆
-
76
◆
Lamp Included, Clear
Lamp Included, Deluxe
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
185
Quartz Flood Series 570
Floodlight
500W Quartz
P R O D U C T
O V E R V I E W
Features:
Rugged, die-cast aluminum housing is powder-coated for durability and
corrosion resistance; bronze is standard color.
Single door access to lamp and electrical components for quick, easy
installation and servicing.
Suitable for -30°C MH & MV / -40°C HPS.
UL listing is standard.
Lens is thermal-, shock- and impact-resistant tempered glass.
Applications:
Transportation terminals
Building facades
Sports lighting
Parking lots
Industrial areas
Commercial areas
Residential areas
Security lighting
Fixture Available
570-61/L
Clear lamp included (120V)
DIMENSIONS
9-1/2"
(241)
7"
(178)
3-1/2"
(89)
7"
(178)
Effective Projected Area (EPA)
The EPA for the Floodlight, Series 570 is 0.72 sq. ft.
Approx. Wt. = 3.5 lbs.
186
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
Quartz Flood Series 474
Floodlight
1500W Quartz
O R D E R I N G
I N F O R M AT I O N
Features:
Rugged die-cast aluminum housing is powder-coated for durability and
corrosion resistance, bronze is standard color.
Single door access to lamp and electrical components for quick, easy
installation and servicing.
Permanently attached bezel is secured by twin captive spring latches.
UL listing is standard.
Lens is thermal-, shock- and impact-resistant tempered glass for lamp
protection.
Applications:
Transportation terminals
Building facades
Sportslighting
Parking lots
Industrial areas
Commercial areas
Residential areas
Security lighting
Fixtures Available
474-61/L-240V
474-61/L-277V
Lamp included (240V)
Lamp included (277V)
DIMENSIONS
Effective Projected Area (EPA)
The EPA for the Floodlight, Series 474 is 1.13 sq. ft.
Approx. Wt. = 5.5 lbs.
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
187
AmeriSport™ Series ASP
Sportslighting
400-1500W MH
W
PP RR OO DD UU CC TT OO VV EE RR VV II EE W
Features:
NEW
Two-piece, die-cast aluminum ballast housing mounted to galvanized steel
trunnion. Ballast is removable and hinged with captive fastener. Steel trunnion
features vertical and horizontal aiming scale with vertical repositioning stop.
All external hardware is stainless steel.
White corrosion-resistant polyester powder finish standard; other
architectural colors available.
Heavy-gauge anodized reflector with six distributions available. "Flux manager"
available for optimal glare and spill light control. Transverse mounting of lamp.
Lamp support included. Optical chamber sealed to inhibit entrance of
contaminants. Hinged lens is thermal-, shock- and impact-resistant tempered
glass. Lens frame is galvanized and secured by stainless steel spring clips for
servicing of lamp. US. Patent no. 6,190,023. Canada Patent no. 2,212,014.
Fixture mounted by securing trunnion directly to cross arm. Mounting
hardware provided.
Suitable for -30°C MH & MV / -40°C HPS.
Applications:
UL listed, suitable for wet locations. Below horizontal aiming orientation only.
Listed and labeled to comply with Canadian Standards.
Stadiums
Sports fields
Arenas
Tracks
Courts
All electrical components warranted by AEL’s 6-year guarantee.
DIMENSIONS
20
(50.8)
24-1/2
(62.2)
Effective Projected Area (EPA)
The EPA for the Sports Floodlight Series SF is 2.39 sq. ft.
Approx. Wt. = 55 lbs.
188
Product Guide
For photometric information, please visit our website,
www.americanelectriclighting.com
AmeriSport™ Series ASP
Sportslighting
400-1500W MH
O R D E R I N G
I N F O R M AT I O N
Example: A S P X 5 M C A M T 1 G N
ASP AmeriSport
40 400W
X1 1000W
X5 1500W
Voltage
Ballast
Wattage / Source
Series
M Metal
Halide
CA CWA
SC SCWA
(Pulse Start)1
CT CWI2
120
208
220
240
277
347
480
MT1
MT8
MT2
MT7
TT1
TT7
TT3
120V
208V
220V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
Tri-tap wired 120
Tri-tap wired 347
Tri-tap wired 277
Optics
G General purpose
H Heavy-duty
Distribution
N
M
W
NX
Narrow Beam
Medium Beam
Wide Beam
Narrow Beam with
Flux Manager
DX Medium Beam with
Flux Manager
WX Wide Beam with
Flux Manager
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Listing
(blank) UL Listed (standard)
CS CSA Certified3
XL No Listing
Notes:
1 400W MH only
2 Available in 208 and 240V only
3 Consult factory for CSA availability
4 Single tap only
5 Limited availability, please contact your local
American Electric Lighting representative
6 Must use with heavy-duty optical
7 Must use mating receptacle, provided by others
8 Not available with 1500W, 120V
9 Use with pre-wired gauges and crossarms
10 For use with 0363 cord length and type only
Fusing4
SF Single Fuse (120, 277, 347V)
DF Double Fuse (208, 220, 240, 480V)
Cord Length*
03 3' Cord
05 5' Cord
08 8' Cord
Cord Type*
23 12-3 SEO Cord
43 14-3 SEO Cord
63 16-3 SEO Cord
*Cord length and type should
be combined to form one
number. Ex: 0523
Lamp
LC Lamp Included, Clear
(ships separately)
Frequency
5H 50 Hertz Ballast Frequency5
Filter
CF Charcoal Filter6
Quartz Restrike
QS Quartz Restrike (Lamp not included)
Connector
3P 3-Prong Plug7,8,9,10
Ordering/Packaging Options
To accommodate the product’s physical configuration as well as a range of customer handling and
processing needs, alternative ordering/packaging methods are available.
Example: (21) ASP X5M CA MT1 GN
This can be ordered/packaged as:
1. Standard Packaging (Optimized form) To order, use single catalog number shown in example
above. Fixture ships as multiple components using optimized packaging.
Example ships as:
(Qty 21) ASP X5M CA MT1 HSG (21 housing cartons)
(Qty 20) ASP GN J4 (5 cartons of 4 reflectors)
(Qty 1) ASP GN U (1 carton of 1 reflector)
2. Component Packaging. Housings ship in unit cartons. To order, specify package multiples you
prefer (using components from the above list). Fixtures ship as separate components in package
multiples you choose.
Example: (Qty 21) ASP X5M CA MT1 HSG (21 cartons of 1 housing)
ASP 20B J4 (5 cartons of 4 reflectors) and ASP 20B U (1 carton of 1 reflector)
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
189
Sportslighting Series SPF
High-Intensity Sports Floodlight
400W HPS, 1000W HPS, 400W MH, 1000W MH, 1500W MH
P R O D U C T
O V E R V I E W
Features:
NEW
Heavy-gauge, hydroformed, aluminum ballast housing is mounted to integral
die-cast monoframe with horizontal degree aiming scale and repositioning
locator. Die-cast aluminum socket housing provides vertical aiming adjustment,
complete with degree aiming scale and repositioning stop.
Heavy-gauge, anodized, aluminum reflectors provide a range of NEMA beam
spreads. Optical chamber is sealed to inhibit entrance of contaminants. Hinged
lens is heavy-duty thermal-, shock- and impact-resistant tempered glass.
Adjustable mounting bracket standard. Porcelain, mogul-base socket with
copper alloy, nickel-plated screw shell and center contact. UL listed 1500W,
600V.
Fixture is mounted by securing the integral cross-arm mounting bracket directly
to the cross arm. No additional adapters are required. A 5/8"-11UNC mounting
bolt is provided. Exposed bolt length is 1-1/2".
UL listed, suitable for wet locations. Listed and labeled to comply with Canadian
Standards.
Suitable for -30°C MH & MV / -40°C HPS.
Optional painted heavy-duty reflector shroud available to protect the reflector.
Applications:
All electrical components warranted by AEL’s 6-year guarantee.
Stadiums
Sports fields
Arenas
Tracks
Courts
DIMENSIONS
D
L
Dimensions
EPA:
NEMA 2,3:
NEMA 4,5,6:
Diameter: NEMA 2,3:
NEMA 4,5,6:
Length:
NEMA 2,3:
NEMA 4,5,6:
Weight:
53 lbs.
190
Product Guide
2.9 ft.2 (.27 m2)
2.5 ft2 (.23 m2)
23-1/8 (58.7)
21-1/2 (54.6)
30 (76.2)
31-1/2 (80)
24 Kg.
For photometric information, please visit our website,
www.americanelectriclighting.com
Sportslighting Series SPF
High-Intensity Sports Floodlight
400W HPS, 1000W HPS, 400W MH, 1000W MH, 1500W MH
O R D E R I N G
I N F O R M AT I O N
Example: S P F X 5 M C A M T 1 5 5
Wattage / Source
Series
SPF Sports
floodlight
40 400W
X1 1000W
X5 1500W1
Voltage
Ballast
S HPS
M MH
CA CWA
SC SCWA (Pulse
Start)2
CT CWI3
120
208
220
240
277
347
480
MT1
MT8
MT2
MT7
Optics
120V
208V
220V
240V
277V
347V
480V
Multi-tap wired 120V
Multi-tap wired 208V
Multi-tap wired 240V
Multi-tap wired 277V
22
33
44
55
66
2Hx2V
3Hx3V
4Hx4V
5Hx5V
6Hx6V
Options
Maximum number of options is six, for more options please contact your local
American Electric Lighting representative
Listing
(blank) UL Listed (standard)
CS CSA Certified4
Fusing5
SF Single Fuse (120, 277, 347V)
DF Double Fuse (208, 220, 240, 480V)
Lamp
LC Lamp Included, Clear
(ships separately)
Coating
TC Non-stick protective coating, black only
Aiming
AH Above Horizontal
Filter
CF Charcoal Filter12
Quartz
QS Quartz Restrike13
*Cord length and type should
be combined to form one
number. Ex: 0523
Shield
GS Glare Shield
HG Hail Shroud and Glare Shield
RS Reflector (Hail) Shroud7
Louver
LV Internal Louver
Bolt
LB Extended Bolt for Wood Crossarm
Support
LT Lamp Support
Connector
3P 3 Prong Plug8,9,10,11
1
2
3
4
4
5
6
7
8
9
10
11
12
13
Cord Length* Cord Type*
23 12-3 SEO Cord
03 3' Cord
43 14-3 SEO Cord
05 5' Cord
63 16-3 SEO Cord
08 8' Cord
Frequency
5H 50 Hertz Ballast Frequency6
Notes:
Metal Halide only
400W MH Only
Available in 208 and 240V only. Not available in
HPS.
Consult factory for CSA availability
Must use mating receptacle, provided by others
Available in single tap only
Limited availability, please contact your local
American Electric Lighting representative
Heavy-duty anodized aluminum shroud
Must use mating receptacle, provided by others
Use with prewired cage and crossarms
For use with 0363 cord length and type only
Not available with 1500W, 120V
For use with reflector shroud (RS option) only
Lamp not included
Ordering/Packaging Options
To accommodate the product’s physical configuration as well as a range of
customer handling and processing needs, alternative ordering/packaging methods
are available.
Example: (21) SPF X5M CA MT7 33
This can be ordered/packaged as:
1. Standard Packaging (Optimized Form) To order, use single catalog number shown
in example above. Fixture ships as multiple components using optimized packaging.
Example ships as:
(Qty 21) SPF X5M CA MT7 N3 HSG (21 housing cartons)
(Qty 20) SPF 20B J4 (5 cartons of 4 reflectors)
(Qty 1) SPF 20B U (1 carton of 1 reflector)
2. Component Packaging. Housings ship in unit cartons. To order, specify package
multiples you prefer (using components from the above list). Fixtures ship as
separate components in package multiples you choose.
Example: (Qty 21) SPF X5M CA MT7 N3 HSG (21 cartons of 1 housing)
SPF 20B J4 (5 cartons of 4 reflectors and SPF 20B U (1 carton of 1 reflector)
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
191
Accessories
G L A R E
S H I E L D S
Catalog
Number
Approx.
Wt. (lbs.)
Item
6"
(152)
75-GS
75-VS
14-3/4"
(375)
75-WG
ULTRA FLOOD GLARE SHIELD
Manufactured of corrosion-resistant aluminum.
For use with Ultra Flood, Series 75. Standard
finish is bronze.
POLYCARBONATE VANDAL SHIELD
2
ULTRA FLOOD GLARE SHIELD
Manufactured of corrosion-resistant aluminum.
For use with Ultra Flood, Series 77. Standard
finish is bronze.
POLYCARBONATE VANDAL SHIELD
2
COMPACT FLOOD GLARE SHIELD
Manufactured of corrosion-resistant aluminum.
For use with Series 51. Standard
finish is bronze.
2
1/2"
(13)
(152)
77-GS
15-7/8"
(403)
77-VS
7/8"
(21)
9.5"
4.5"(114) (241)
51-GS
17" (178)
75 PGS 40W
77 PGS X1W
51 PGS 40W
Ballastic Shield
Notes:
Floodlighting
51-GS1
75-GS1,2
75-VS2
75-WG2
77-GS1,2
77-VS2
192
Product Guide
51
◆
-
75
◆
◆
◆
-
77
◆
◆
1
2
For other finishes, please contact your local American Electric
Lighting representative (standard finish is noted on accessory
details, pg 193-196)
Wire guards, vandal shields and glare shields cannot be used
simultaneously
For photometric information, please visit our website,
www.americanelectriclighting.com
Accessories
For Mounting to Wood Poles
S T E E L
Catalog
Number
M O U N T I N G
Effective
Projected
Area (Sq. Ft.)*
Approx.
Wt. (lbs.)
SINGLE-UNIT BRACKET — Manufactured of 2” steel
pipe with a minimum yield of 35,000 PSI.
Requires two 1/2” lag screws, one 5/8” through-bolt
and one 2” square flat washer. Prime-coated finish.
.7
5
SINGLE-UNIT BRACKET — Manufactured of 2” steel
pipe with a minimum yield of 35,000 PSI.
Requires two 1/2” lag screws, one 5/8” through-bolt
and one 2” square flat washer. Prime-coated finish.
.7
13
SINGLE-UNIT BRACKET — Fixture bracket is 3”- 3
5/16” angle steel with 3/4” - 11/2” steel bolts. Unit of
2'' steel pipe with minimum yield strength of 35,000 PSI.
Requires two 1/2” lag screws, one 5/8” through-bolt
and one 2” square flat washer. Prime-coated finish.
.8
141/4
TWIN-UNIT BRACKET — Each fixture bracket is 3”- 3
.8
271/4
TWIN-UNIT BRACKET — Manufactured of 2” steel
pipe with a minimum yield strength of 35,000 PSI.
Requires two 1/2” lag screws, one 5/8” through-bolt
and one 2” square flat washer. Prime-coated finish.
1.4
24
THREE- UNIT BRACKET — Manufactured of 2” steel
pipe with minimum yield strength of 35,000 PSI.
Requires two 1/2” lag screws, one 5/8” through-bolt
and one 2” square flat washer. Prime-coated finish.
1.9
27
Item
9201
B R A C K E T S
18''
9254
23''
87/8''
9204
9205
5/16” angle steel with 3/4” - 11/2” steel bolts. Unit of
2” steel pipe with minimum yield strength of 35,000 PSI.
Requires two 1/2” lag screws, one 5/8” through-bolt
and one 2” square flat washer. Prime-coated finish.
9252
9252-G
(Galvanized)
9253
9253-G
(Galvanized)
NOTE: Above brackets available with GALVANIZED FINISH; to order add -G suffix to catalog number. (Example: 9252-G.)
Floodlighting
92011,2,4
92541,2,4
92041,2,4
92051,2,3
92521,2,3
9252-G1,2,4
92531,2,4
9253-G1,2,4
51
◆
◆
◆
◆
◆
◆
◆
◆
75
◆
◆
◆
◆
◆
◆
◆
◆
77
◆
◆
◆
◆
◆
◆
◆
◆
Footnotes
1
2
3
4
Designed to accommodate fixtures with a max. weight of
65 lbs. and an epa of 4.0
For other finishes, please contact your local
American Electric Lighting representative
(standard finish is noted above)
Yoke mount only
Tenon mount only
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
193
Accessories
M O U N T I N G
H A R D W A R E
Catalog
Number
9902-H
ALUMINUM POLE-TOP MOUNT
Slipfitter mounting. Positive three-point mounting support and
corrosion-resistant hardware. Fits 2” or 21/2” pipe (2” pipe intrudes
31/16”, 21/2” pipe intrudes 23/4”.) Furnished with mounting bolts,
set screws and compression fitting for cable entry.
Top cover removable for wiring.
3
9906
PIPE CLAMP MOUNT
Plated steel and cast aluminum clamp mount with corrosion-resistant
hardware for 11/2” or 2” pipe installations.
3
9909
PIPE CLAMP MOUNT
Plated steel and cast aluminum clamp mount with corrosion-resistant
hardware for 3” pipe installations.
5
Notes:
Floodlighting
99021
99061
99091
194
Approx.
Wt. (lbs.)
Item
Product Guide
51
◆
◆
◆
75
◆
◆
◆
77
◆
◆
◆
1
For other finishes, please contact your local American Electric
Lighting representative (standard finish is noted above)
For photometric information, please visit our website,
www.americanelectriclighting.com
Accessories
For Mounting to Steel Poles
S T E E L
Catalog
Number
M O U N T I N G
B R A C K E T S
Effective
Projected
Approx.
Area (Sq. Ft.) Wt. ( lbs.)
Item
9333
THREE-ARM POLE-BRACKET—12” spread, arms
@ 120° 2” (23/8” OD) standard pipe tenon and slipfitter base for mounting to standard 2” pipe tenons.
Prime-coated finish.
1.2
34
9343
FOUR-ARM POLE-TOP BRACKET—48” spread,
arms @ 90°, 2” (23/8” OD) standard pipe tenon and
slipfitter base for mounting to standard 2'' pipe
tenons. Prime-coated finish.
.90
45
9352
TWO-ARM POLE-TOP BRACKET — 30” spread, 2”
(23/8” OD) standard pipe tenon and slipfitter base for
mounting to standard 2” pipe tenons. Prime-coated
finish.
.87
21
9353
THREE-ARM POLE-TOP BRACKET — 30” spread
between tenons, 2” (23/8” OD) standard pipe tenon
and slipfitter base for mounting to standard 2” pipe
tenons. Prime-coated finish.
1.7
34
9354
FOUR-ARM POLE-TOP BRACKET — 30” spread
between tenons, 2” (23/8” OD) standard pipe tenon
and slipfitter base for mounting to standard 2” pipe
tenons. Prime-coated finish.
2.3
45
NOTE: Above brackets available with GALVANIZED FINISH; to order add -G suffix to catalog number. (Example: 9252-G)
For Steel, Aluminum, Fiberglass and Wood Poles refer to the Pole section or call your local
American Electric Lighting representative.
Floodlighting
93331,2
93431,2
93521,2
93531,2
93541,2
Notes:
51
◆
◆
◆
◆
◆
75
◆
◆
◆
◆
◆
77
◆
◆
◆
◆
◆
1
2
For other finishes, please contact your local American Electric
Lighting representative (standard finish is noted above)
Tenon mount only
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
195
Options and Accessories
A S P
CF
ACRA
ACRA45
LV
ARWB
ASAB
ASPMB
ATS
ACRW2
ACRW3
ACRW4
/
S P F
ASP
■
❑
N/A
N/A
❑
❑
❑
■
❑
❑
❑
Charcoal filter
Crossarm adapter for horizontal mounting
Crossarm adapter for horizontal mounting 45°
Internal bottom louver
Radius wall bracket. Standard finish is dark bronze
Steel angle bracket. Standard finish is dark bronze
Pipe/wood/pole/wall mounting bracket. Mounts to 2” schedule 40 pipe
Tenon slipfitter, fits 2-3/8” to 2-7/8” OD tenon
2-light wood pole
3-light wood pole
4-light wood pole
SPF
■
❑
❑
■
❑
❑
❑
■
❑
❑
❑
■ = Available as an option, shipped installed
❑ = Available as an accessory, shipped separately
3-1/4"
(8.3cm)
ARWB
ATS
5/8" Clearance
Hole
Furnished with
weather-tight cord
grip for 14-3 SO cord.
(Grip for 12-3 SO optional.)
4-7/8"
(12.4cm)
Wire
Access
4"
(10.2cm)
ACRA
5/8" x 1" hex bolt and
lockwasher furnished
5/8" x 1" hex bolt
and lockwasher
furnished
1-1/4"
(3.2cm)
ACRA45
Fixture yoke
Pivot slot for
1/2" bolt (not
provided)
00
00
00
Floodlight
yoke
Pivot hole for 5/8"
bolt (not rovided)
00
Degree markings
ACRW2
00
00
00
6"
(15.2cm)
00
00
00
4-1/2"
(11.4cm)
00
Pivot slot for
1/2" bolt
Pivot hole for 5/8"
bolt (not provided)
Degree markings
ACRW3
36"
(91.4cm)
ACRW4
66"
(167.6cm)
ASMB
5/8" x 1" hex bolt
and lockwasher
furnished
8-11/16"
(22.1cm)
1/2" x 1-1/2"
hex bolt and
flat washer
furnished
5/8" x 1-1/2" bolt,
lockwasher and
nut furnished
11/16" diameter hole for
5/8" thru-bolt
4"
(10.2cm)
12-1/2"
(31.8cm)
(2) 3/8" U-bolt
furnished with
nuts and
washers
Product Guide
ASAB
4-3/16"
(10.6cm)
4-3/4"
(12.1cm)
3-3/8"
(8.6cm)
196
96"
(243.8cm)
Fits 2" or
2-1/2" pipe
(horizontal
or vertical)
For photometric information, please visit our website,
www.americanelectriclighting.com
20-1/8"
(51.1cm)
9/16" diameter holes
for lag bolts (not
provided)
Floodlighting
B A L L A S T
M AT R I C E S
Series 51
Watts
120
05S
RH, RN
07S
RH, CA, CT, RN, MR
10S
CA, CT, MR, RH, RN
10V
XH, XN, CA, CT
15S
RN, RH, CA, CT, MR
17V
XN, XH, CA ,CT
17M
CA
20S
CA, CT, XN, XH
25S
XH, XN, CA, CT
25V
CT, CA, XN, XH
25M
CA, CT, SC
31S
CA, MR
40S
CA, CT, XN, XH
40V
CA, CT, XN, XH
40M
CA, CT, SC
23/24S
CA, CT
23/24M
CA
208
220
XH, XN
XH, CA, CT ,XN
XH, CA, CT, XN
CA
CA, CT, XN, XH
CA
RN5,CA
CA
CA, CT
CA, CT
CA5,RN5,RH
CA
CA
CA, CT, SC
CA
CA
CA, CT
RN5,RH
CA, CT
CA, CT, SC
CA
CA, CT
CA
-
230
RN,RH
RN,RH
RN,RH
RN,RH
RN,RH
-
240
XH, XN
XH, CA, CT, MR, XN
XH, CA, CT, MR, XN
CA, CT
CA, CT, XN, XH, MR
CA, CT, RN, RH
CA
CA, CT, RN, RH
RN, RH, CA, CT
RH, RN, CA, CT
CA, CT, SC
CA, MR
RH, RN, CA, CT
CA, CT, XN, XH
CA, CT, SC
CA, CT
CA
277
XH, XN
XH, CA, XN, CT
CA, XH, XN, CT
XN, XH, CA
XN, XH, CA
CA, RN
CA
CA, CT
CA, CT
CA
CA, SC
CA
CA, CT
CA, CT
CA, SC
CA, CT
CA
480
MR
CA
CT
CA, MR
CA, CT
CA
CA, CT
CA, MR
CA, CT
CA, CT
CA
CA
CT, CA
CA, CT
CA
CA
DT1
XH, XN
XH, XN, CA, CT, MR
CA, CT, XH, MR, XN
CT
XN, XH, CA, CT, MR
CT, CA
CA
XN, XH, CA, CT
XN, XH, MR
CA, CT
CA, CT, SC
CA,
CA, CT, XN, XH
CA, CT, XN, XH
CA, CT
CA, CT
CA
DT2
XH, XN
XH, XN, CA, CT, MR
CA, CT, MR, XH, XN
CT, CA
XN, XH, CA, CT, MR
CT, CA
CA
XN, XH, CA, CT
XN, XH
CA, CT
CA, CT, SC
CA
CA, CT, XN, XH
CA, CT, XN, XH
CA, CT
CA, CT
CA
DT3
MR
CT
MR
CT
CT
CT
CT
CT
-
DT4
MR
CT
MR
CT
CT
CT
CT
CT
-
Series 51 continued
Watts
05S
07S
10S
10V
15S
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
23/24M
MT1
XH, XN
XH, XN, CA, CT
CA, XN, XH, CT
CA
XN, XH, CA, CT
CA
CA
CT, CA
CA, CT
CA
CA, SC
CA
CA, CT
CA
CA, SC
CA, CT
CA
MT2
XN, XH
XH, XN, CA, CT
CA, XN, XH, CT
CA
XN, XH, CA, CT
CA
CA
CT, CA
CA, CT
CA
CA, SC
CA
CA, CT
CA
CA, SC
CA, CT
CA
MT7
XN, XH
XH, XN, CA, CT
CA, XN, XH, CT
CA
XN, XH, CA, CT
CA
CA
CT, CA
CA, CT
CA
CA, SC
CA
CA,CT
CA
CA, SC
CA, CT
CA
MT8
XN, XH
XH, XN, CA, CT
CA, XN, XH, CT
CA
XN, XH, CA, CT
CA
CA
CT, CA
CA, CT
CA
CA, SC
CA
CA, CT
CA
CA, SC
CA, CT
CA
TT1
XN, XH
XN, XH
XN, XH
XN, XH
CA
CA
CA
CA
CA
CA
-
TT7
XN, XH
XN, XH
XN, XH
XN, XH
CA
CA
CA
CA
CA
CA
-
TT3
XN, XH
XN, XH
XN, XH
XN, XH
CA
CA
CA
CA
CA
CA
-
347
XN, XH, CA, CT
XN, XH
XN, XH
XN, XH, CA
CA
CA
CA
CA
CA
CA
CA
-
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
197
Floodlighting
B A L L A S T
M AT R I C E S
Series 75
Watts
10S
10V
15S
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
23/24M
120
CA, CT, MR, RH, RN
XH, XN, CA, CT
RN, RH, CA, CT, MR
XN, XH, CA, CT
CA
CA, CT, XN, XH ,MR
XH, XN, CA, CT
CT, CA, XN, XH
CA, CT, SC
CA, MR
CA, CT, XN, XH
CA, CT, XN, XH
CA, CT, SC
CA, CT
CA
208
XH, CA, CT, XN
CA
CA, CT, XN, XH
CA
CA
CA, CT
CA, CT
CA
CA, CT, SC
CA
CA, CT
CA, CT
CA, CT, SC
CA, CT
CA
220
RN, CA
CA, RN, RH
CA
CA
RN, RH
CA
-
230
RN, RH
RN, RH
RN, RH
RN, RH
-
240
XH, CA, CT, MR, XN
CA, CT
CA, CT, XN, XH, MR
CA, CT, RN, RH
CA
CA, CT, RN, RH, MR
RN, RH, CA, CT
RH, RN, CA, CT
CA, CT, SC
CA, MR
RH, RN, CA, CT
CA, CT, XN, XH
CA, CT, SC
CA, CT
CA
277
480
CA, XH, XN, CT
CA
XN, XH, CA
CT
XN, XH, CA
CA, MR
CA, RN
CA, CT
CA
CA
CA, CT
CA, CT, MR
CA, CT
CA
CA
CA, CT
CA, SC
CA, CT
CA
CA
CA, CT
CA
CA, CT
CT, CA
CA, SC
CA, CT
CA, CT
CA
CA
CA
DT1
CA, CT, XH, MR, XN
CT
XN, XH, CA, CT, MR
CT, CA
CA
XN, XH, CA, CT, MR
XN, XH, MR
CA, CT
CA, CT, SC
CA,
CA, CT, XN, XH
CA, CT, XN, XH
CA, CT
CA, CT
CA
DT2
CA, CT, MR, XH, XN
CT, CA
XN, XH, CA, CT, MR
CT, CA
CA
XN, XH, CA, CT, MR
XN, XH
CA, CT
CA, CT, SC
CA
CA, CT, XN, XH
CA, CT, XN, XH
CA, CT
CA, CT
CA
Series 75 continued
Watts
10S
10V
15S
17V
17M
20S
25S
25V
25M
31S
40S
40V
40M
23/24S
23/24M
MT1
CA, XN, XH, CT
CA
XN, XH, CA, CT
CA
CA
CT, CA
CA, CT
CA
CA, SC
CA
CA, CT
CA
CA, SC
CA
MT2
CA, XN, XH, CT
CA
XN, XH, CA, CT
CA
CA
CT, CA
CA, CT
CA
CA, SC
CA
CA, CT
CA
CA, SC
CA
MT7
CA, XN, XH, CT
CA
XN, XH, CA, CT
CA
CA
CT, CA
CA, CT
CA
CA, SC
CA
CA, CT
CA
CA, SC
CA, CT
CA
MT8
CA, XN, XH, CT
CA
XN, XH, CA, CT
CA
CA
CT, CA
CA, CT
CA
CA, SC
CA
CA, CT
CA
CA, SC
CA, CT
CA
TT1
XN, XH
XN, XH
XN, XH
CA
CA
CA
CA
CA
CA
CA, CT
CA
TT7
XN, XH
XN, XH
XN, XH
CA
CA
CA
CA
CA
CA
CA, CT
CA
TT3
XN, XH
XN, XH
XN, XH
CA
CA
CA
CA
CA
CA
-
347
XN, XH
XN, XH
XN, XH, CA
CA
CA
CA
CA
CA
CA
CA
-
Series 77
Watts
40S
40V
40M
75S
75M
100S
100V
100M
120
CA, CT, XN, XH, MR
CA, CT, XN, XH
CA, CT, SC
CA
SC
CA, CT
CA
CA, SC
208
CA, CT
CA, CT
CA, CT, SC
CA
SC
CA, CT
CA
CS, SC
220
RN, RH
CA
CA
240
RH, RN, CA, CT, MR
CA, CT, XN, XH
CA, CT, SC
CA
SC
CA, CT
CA
CA, SC
277
CA,CT
CA, CT
CA, SC
XX
SC
CA, CT
CA
CA, SC
480
CA, MR
CT, CA
CA, CT,
SC
CA, CT
CA
CA, SC
DT1
DT2
CA, CT, XN, XH, MR CA, CT, XN, XH, MR
CA, CT, XN, XH
CA, CT, XN, XH
CA, CT
CA, CT
CA
CA
SC
SC
CA, CT
CA,CT
CA
CA
CA, SC
CA, SC
Series 77 continued
Watts
40S
40V
40M
75S
75M
100S
100V
100M
198
MT7
CA, CT
CA
CA, SC
SC
CA
CA
CA, SC
MT8
CA, CT
CA
CA, SC
SC
CA
CA
CA, SC
Product Guide
TT1
CA
CA
CA
SC
CA, SC
TT7
CA
CA
CA
SC
CA, SC
TT3
CA
CA
CA
SC
CA
CA, SC
347
CA
CA
CA
SC
CA,SC
For photometric information, please visit our website,
www.americanelectriclighting.com
DT3
MR
CT
CT
-
DT4
MR
CT
CT
-
MT1
CA, CT
CA
CA, SC
SC
CA
CA
CA, SC
MT2
CA, CT
CA
CA, SC
SC
CA
CA
CA, SC
DT3
CT
MR
CT
MR
CT
CT
CT
CT
-
DT4
CT
MR
CT
MR
CT
CT
CT
CT
-
DARK TO LIGHT TM
ELECTRONIC PHOTOCONTROLS
DE Series .................................................................200
DD Series.................................................................201
DPN Series ..............................................................202
DP Series .................................................................203
D Series....................................................................204
DX Series .................................................................205
DUX Series ..............................................................206
DBE Series...............................................................207
DB Series.................................................................208
DA Series.................................................................209
D779 Series..............................................................210
Shorting Caps..........................................................211
Photocontrol Accessories ....................................212
Photocontrol Recommendation Chart ................212
ANSI Color Chart ....................................................212
American Electric Lighting™
DE Series Filtered Silicon
Electronic Twist Lock Photocontrol
O R D E R I N G
I N F O R M AT I O N
Features:
Filtered silicon light sensor.
Human eye spectral response.
Complies with ANSI C136.10-1996.
MOV surge protection.
Long life.
Energy efficient.
Four-year warranty.
Available in job packs of J12 and J50 only.
Silicon sensor with infrared blocking filter.
Polypropylene cover, neoprene gasket, brass legs, acrylic window.
Base rated for 120°C.
Applications:
Power consumption: 0.5 watts.
Roadway and area lighting
Areas with variable sky conditions
Areas with high temperatures
Load rating: 1000 watts, 1800 VA ballast.
Sealed relay rated for 5000 operations at full load.
Turn OFF light level is 1.5 times turn ON.
3.4 ounces each.
-40°C to +70°C ambient, up to 90°C interface per ANSI.
Dielectric strength: 5000 V per ANSI.
Ordering Information
DE240
DE347
DE480
Time Delay (seconds)1
Turn-on Level (ftc)1
Voltage
DE120
DE124
Example: D E 1 2 0 - 1 . 5 - T J J 5 0
120 volts (105–130)
120/240/277 volts
(105–305)
240 volts (185–305)
347 volts (300–400)
480 volts (420–530)
1.0
1.5
2.6
8.0
35
Energy saver
ANSI standard
IES recommendation
Automile
FAA
T
2-5 second turn-off
delay (standard)
Surge Protector
J
320 J/13,000 amp
MOV
Cover Color 1
Job Packs
(blank) ANSI standard
color*
BK Black
BR Brown
P Upward facing
J12 12 units
J50 50 units
* See chart page 212
DIMENSIONS
2-1/8"
(52)
2-1/8"
(52)
Notes:
1
3-1/8"
(76)
3-1/8"
(76)
Upward Facing
200
Product Guide
For more information, visit our website,
www.americanelectriclighting.com
Other options available,
please contact your local
American Electric Lighting
representative
DD Series Diagnostics
Electronic Twist Lock Photocontrol
O R D E R I N G
I N F O R M AT I O N
Features:
Regular dusk-to-dawn operation.
Diagnostic feature detects and disables cycling HPS lamps and
lamps that fail to start.
Extends starting aids life.
Flashing or steady LED alerts line crew of problem.
Filtered silicon light sensor.
2-5 second off delay.
MOV surge protection.
Complies with ANSI C136.10-1996; not for use on incandescent fixtures.
Four-year warranty.
Available in job packs of J12 or J50 only.
Applications:
Polypropylene cover, neoprene gasket, brass legs, acrylic window base rated
for 120°C.
Roadway and area lighting
High profile installations
Anywhere cycling lamps are a problem
Anywhere starting aid life is a problem
Power consumption: 1.0 watts.
Load rating: 70-400 watt HPS.
Sealed relay rated for 5000 operations at full load.
3.8 ounces each.
-40°C to +70°C ambient, up to 90°C interface per ANSI.
Dielectric strength: 5000 V per ANSI.
Ordering Information
Example: D D 1 2 4 - 1 . 5 - T J A J 5 0
Voltage
DD124
120/208/240/277
volts (105-305)
1.5
ANSI standard
T
2-5 second turn-off
delay (standard)
Surge Protector
J
DIMENSIONS
Cycle Detection1
Time Delay (seconds)
Turn-on Level (ftc)
320J/13,000 amp
MOV
2-1/8"
(52)
A
B
Job Packs
After five lamp cycles,
control turns lamp off. Next
dusk, control turns lamp on
and cycle detection
circuit restarts.
After five lamp cycles, control
removes power from lamp
until control is reset.
Lamp remains off until
power is removed from
control for 30 seconds.
J12
J50
12 units
50 units
Notes:
1
3-1/8"
(76)
See pages 259-264 for a complete listing
of Frequently Ordered Products
Available with black cover only.
Cycle Detection Program is set at
factory; program cannot be altered
in field
Product Guide
201
DPN Series Part Night®
Electronic Twist Lock Photocontrol
O R D E R I N G
I N F O R M AT I O N
Features:
Control turns on at dusk and off halfway through the night. Automatically
self-adjusts to seasonal time changes, reducing maintenance.
Reduces light pollution and light trespass concerns.
Filtered silicon photocell provides long-term, drift-free light sensing.
The infrared blocking polymer filter gives human eye response.
A 2-5 second off-only time delay is provided to avoid turn-off from extraneous
light.
Complies with ANSI C136.10-1996.
Four-year warranty.
Energy Savings.
Star FriendlyTM.
Available in job packs of J12 or J50 only.
Applications:
Polypropylene cover, neoprene gasket, brass legs, acrylic window base rated
for 120°C.
Parking lots
Area lights
Park lights
Media lighting
Ball fields and courts
Pedestrian lighting
Power consumption: 0.8 watts.
Load rating: 1000 watts, 1800 VA ballast.
Sealed relay rated for 5000 operations at full load.
Turn OFF is at middle of the night.
3.6 ounces each.
-40°C to +70°C ambient, up to 90°C interface per ANSI.
Dielectric strength: 5000 V per ANSI.
Example: D P N 1 2 4 - 2 . 6 - T J G N J 5 0
Ordering Information
Time Delay (seconds)
Turn-on Level (ftc)1
Voltage
DPN124 120/240/277 volts
(105-305)
DPN347 347 volts (300-400)
1.0
1.5
2.6
8.0
35
Energy saver
ANSI standard
Standard
Automile
FAA
T
Cover Color
GN
2-5 second turn-off
delay (standard)
Surge Protector
J
Notes:
DIMENSIONS
1
Other options available, please contact
your local American Electric Lighting
representative
2-1/8"
(52)
3-1/8"
(76)
202
Product Guide
320 J/13,000 amp
MOV
For more information, visit our website,
www.americanelectriclighting.com
Green (only)
Job Packs
J12 12 Units
J50 50 Units
DP Series Silicon
Electronic Twist Lock Photocontrol
O R D E R I N G
I N F O R M AT I O N
Features:
Silicon light sensor.
Complies with ANSI C136.10-1996.
MOV surge protection.
Long life.
Energy efficient.
Four-year warranty.
Available in job packs of J12 or J50 only.
Heat stabilized polymers are used in the base, enabling the control to
withstand the high temperatures found on 400 and 1,000 watt HID floodlights
and other fixtures.
Inverse ratio (DPR) and fail off (DPF) options available.
Applications:
Inverse Ratio Controls are ideal for areas where it is important to turn on lights
early but energy costs are a concern. Turn-off level is lower then turn-on
levels. Model listed, PR124-1.5-TJ, is most commonly ordered. Various other
models available. Contact your local American Electric Lighting representative
for details and specifications.
Roadway and area lighting
Floodlights
Areas with very high temperatures
(DP Series High Temperature/Floodlight)
Fail Off Controls are occasionally used for leased lighting. Model DPF124-1.5TJ is most commonly ordered. Various other models available. Contact your
local American Electric Lighting representative for details and specifications.
Ordering Information
Example: D P 1 2 0 - 1 . 5 - T J B K J 5 0
Turn-on Level (ftc)1
Voltage
DP120
DP124
120 volts (105–130)
120/240/277 volts
(105–305)
DP240 240 volts (185–305)
DP347 347 volts (300–400)
DP480 480 volts (420–530)
DPR124 Multi-volt inverse
ratio
DPF124 Multi-volt fail off
1.0
1.5
2.6
8.0
35
Time Delay (seconds)1
T
Energy saver
ANSI standard
IES recommendation
Automile
FAA
2-5 second turn-off
delay
Surge Protector
J
320 J/13,000 amp (blank) ANSI standard color*
MOV
BK Black
BR Brown
P Upward facing
* See chart page 212
Job Packs
J12 12 units
J50 50 units
DIMENSIONS
2-1/8"
(52)
2-1/8"
(52)
3-1/8"
(76)
Cover Color 1
3-1/8"
(76)
Notes:
1
Other options available, please contact
your local American Electric Lighting
representative
Upward Facing
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
203
D Series Classic
Electronic Twist Lock Photocontrol
O R D E R I N G
I N F O R M AT I O N
Features:
Cadmium sulfide light sensor.
Exceeds ANSI C136.10-1996.
MOV surge protection.
Long life.
Energy efficient.
Four-year warranty.
Available in job packs of J12 or J50 only.
Polypropylene cover, neoprene gasket, brass legs, acrylic window
base rated for 120°C.
Power consumption: 0.5 watts.
Load rating: 1000 watts, 1800 VA ballast.
Applications:
Sealed relay rated for 5000 operations at full load.
Roadway and area lighting
Turn OFF light level is 1.5 times turn ON.
3.4 ounces each.
-40°C to +70°C ambient, up to 90°C interface per ANSI.
Dielectric strength: 5000 V per ANSI.
Ordering Information
Example: D 1 2 4 - 1 . 5 - S T J J 5 0
Voltage
D120
D124
D240
120 volts (105–130)
120/240/277 volts
(105–305)
240 volts (185–305)
1.0
1.5
2.6
Energy saver
ANSI standard
IES recommendation
T
2-5 second turn-off
delay
Surge Protector
Light Sensor
S
Cover Color 1
Time Delay (seconds)1
Turn-on Level (ftc)1
Standard
cadmium sulfide
J
(blank)
BK
BR
P
ANSI standard color*
Black
Brown
Upward facing
* See chart page 212
Notes:
1
2-1/8"
(52)
1-1/2"
(37)
3-1/8"
(76)
Upward Facing
204
Product Guide
J12 12 units
J50 50 units
320 J/13,000 amp
MOV
DIMENSIONS
2-7/8"
(70)
Job Packs
For more information, visit our website,
www.americanelectriclighting.com
Other options available,
please contact your local
American Electric Lighting
representative
DX Series Basic
Electronic Twist Lock Photocontrol
O R D E R I N G
I N F O R M AT I O N
Features:
Silicon light sensor.
Complies with ANSI C136.10-1996.
MOV surge protection.
Long life.
Energy efficient.
Economical.
Three-year warranty.
Available in job packs of J12 or J50 only.
Standard 160 joule, 6500 amp MOV rated for multiple surges.
Polypropylene cover, Neoprene gasket, brass legs, acrylic window base rated
for 120°C.
Applications:
Power consumption: 0.5 watts.
Roadway and area lighting
Security lighting
Municipal lighting
Load rating: 1000 watts, 1800 VA ballast.
Sealed relay rated for 5000 operations at full load.
3.4 ounces each.
-40°C to +70°C ambient, up to 90°C interface per ANSI.
Dielectric strength: 5000 V per ANSI.
Example: D X 1 2 4 - 1 2 A J 5 0
Ordering Information
Voltage
DX120
DX124
DX347
DX480
Sensor
Turn-on Level (ftc)
120 volts (105–130)
120/240/277 volts
(105–305)
347 volts (300–400)
480 volts (420–530)
1
1.2–3 ftc turn-on
(standard)
2
Silicon sensor, time
delay (2-5 seconds)
A
P
Cover Color
Job Packs
ANSI standard*
Upward facing
J12 12 units
J50 50 units
* See chart page 212
DIMENSIONS
2-1/8"
(52)
1-1/2"
(37)
2-7/8"
(70)
3-1/8"
(76)
Upward Facing
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
205
DUX Series Basic
Twist Lock Photocontrol
O R D E R I N G
I N F O R M AT I O N
Features:
Silicon light sensor.
Complies with ANSI C136.10-1996.
MOV surge protection.
Long life.
Energy efficient.
Economical.
Three-year warranty.
Available in job packs of J12 or J50 only.
Standard 160 joule, 6500 amp MOV rated for multiple surges.
Polypropylene cover, Neoprene gasket, brass legs, acrylic window base rated
for 120°C.
Applications:
Area lighting
Security lighting
Yard lighting
Power consumption: 0.5 watts.
Load rating: 1000 watts, 1800 VA ballast.
Sealed relay rated for 5000 operations at full load.
3.4 ounces each.
-40°C to +70°C ambient, up to 90°C interface per ANSI.
Dielectric strength: 5000 V per ANSI.
UL listed.
Example: D U 1 2 0 - 1 2 A J 5 0
Ordering Information
Voltage
DUX120 120 volts (105–130)
DUX124 120/240/277 volts
(105–305)
DUX347 347 volts (300–400)
DUX480 480 volts (420–530)
1
2
1.2–3 ftc turn-on
(standard)
Silicon sensor, time
delay (2-5 seconds)
2-1/8"
(52)
1-1/2"
(37)
3-1/8"
(76)
Upward Facing
206
Product Guide
A
P
ANSI standard*
Upward facing
* See chart page 212
DIMENSIONS
2-7/8"
(70)
Cover Color
Sensor
Turn-on Level (ftc)
For more information, visit our website,
www.americanelectriclighting.com
Job Packs
J12 12 units
J50 50 units
DBE Series Button
Electronic Wire-In Photocontrol
O R D E R I N G
I N F O R M AT I O N
Features:
Electronic wire-in button photocontrol.
Instant turn-on, standard 5-10 second turn-off time delay.
Filtered Silicon light sensor.
UL Listed models available.
Filtered silicon light sensor.
Voltages 120–347.
Complies with ANSI C136.24.
Long life.
Low maintenance.
Four-year warranty.
Applications:
Available in job packs of J12 or J25 only.
Park lighting
Security lighting
Post lanterns
Decorative and area lighting
Example: D B E 1 2 0 1 . 5 - T J 2 5
Ordering Information
Voltage
DBE120
DBE240
DBE347
Time Delay (seconds)
Turn-on Level (ftc)
120 volts (105–130)
208/240/277 volts
(200–305)
347 volts (300–400)
1.5
ANSI standard
T
5-10 second turnoff delay (standard)
Job Pack
J12
J25
12 units
25 units
DIMENSIONS
3/8” (18) Straight pipe thread
0.80" (20)
(Width)
1.30" (32)
(Height)
1.25" (31)
2.25" (55)
(Length)
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
207
DB Series Button
Electronic Wire-In Photocontrol
O R D E R I N G
I N F O R M AT I O N
Features:
Electronic, utility-grade wire-in button photocontrol.
Instant turn-on, standard 5-10 second turn-off time delay.
Cds cell.
UL Listed models available.
Voltages 120–347.
Complies with ANSI C136.24.
Long life.
Low maintenance.
Four-year warranty.
Available in job packs of J12 or J25 only.
Applications:
Park lighting
Security lighting
Post lanterns
Decorative and area lighting
Ordering Information
Example: D B 1 2 0 - 1 . 5 - S T J 2 5
Turn-on Level (ftc)
Voltage
DB120
DB240
DB347
120 volts (105–130)
208/240/277 volts
(200–305)
347 volts (300–400)
1.5
ANSI standard S
Light Sensor
Standard cadmium T
sulfide
Time Delay
Certification1
Job Packs
5-10 second turn-off (blank) No listing
J12 12 units
delay (standard)
A12 UL listed
J25 25 units
25UA with 12”
leads 1/2”
stripped.
DIMENSIONS
3/8” (18) Straight pipe thread
0.80" (20)
(Width)
1.30" (32)
Notes:
(Height)
1.25" (31)
1
2.25" (55)
(Length)
208
Product Guide
For more information, please visit our website,
www.americanelectriclighting.com
Other options available,
please contact your local
American Electric Lighting
representative
DA Series Button
Wire-In Photocontrol
O R D E R I N G
I N F O R M AT I O N
Features:
Wire-in mechanical button photocontrol.
Instant turn-on, 30-60 second turn-off time delay.
UL Listed models available.
Sealed cds cell.
Voltages 120 and 208/240/277.
Load rating UL773A: 600VA ballast, ANSI: 1000 VA ballast.
Available in job packs of J12 or J25 only.
Complies with ANSI C136.24.
Low maintenance.
One-year warranty.
Applications:
Park lighting
Security lighting
Post lanterns
Decorative and area lighting
Wall packs
Ordering Information
Example: D A 1 2 0 - 1 2 A J 2 5
Voltage
DA120
DA240
Time Delay (seconds)
Turn-on Level (ftc)
1
120 volts (105–130)
208/240/277 volts
(200–305)
ANSI standard
2A
30-60 second turnoff delay (standard)
Job Pack
J12
J25
12 units
25 u1nits
DIMENSIONS
3/8” (18) Straight pipe thread
15” Leads, 18 AWG, 105-degrees C
(Width)
1.1"
(28)
1.0"
(25)
(Height)
.95"
(22)
2.0"
(50.0)
(Length)
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
209
D779 Series
Electronic Locking-Type Photocontrol
O R D E R I N G
I N F O R M AT I O N
Features:
Silicon light sensor.
Complies with ANSI C136.10-1996.
Two-year warranty.
Standard 190 joule, 4500 amp MOV.
Polypropylene cover, neoprene gasket, brass legs, acrylic window
base rated for 120°C
Power consumption: 0.5 watts.
At 120 VAC Load rating: 1000 watts, 1800 VA ballast .
Sealed relay rated for 5000 operations at full load.
Instant turn on, 2-5 second turn off.
Turn on is 1.5 + 0.5 ftc, turn off is 1.5 times turn on.
3.4 ounces each.
Available in job packs of J25 or J50 only.
-40°C to +70°C ambient, up to 90°C interface per ANSI.
Dielectric strength: 5000 V per ANSI.
D7790 is a replacement for many industry standard type locking photocontrols.
Ordering Information
Example: D 7 7 9 0 J 5 0
Job Pack
Voltage
D7790 120/208/240/277 VAC
D7793 347 VAC
D7794 480 VAC
J12
J25
12 Units
25 Units
DIMENSIONS
2-1/8"
(52)
3-1/8"
(76)
210
Product Guide
For more information, please visit our website,
www.americanelectriclighting.com
Shorting Caps
Twist Lock Type
O R D E R I N G
I N F O R M AT I O N
SHORTING AND OPEN CAPS
For luminaires where lights are to be on continuously (shorting cap)
or left off (open cap). Exceeds ANSI C136.10-1996.
Description
Catalog Number
Shorting cap. Black cover.
D-SHORT-SBK
Shorting cap 320J. MOV surge protection. Black cover.
D-SHORT-VBK
Open cap. Red cover.
D-OPEN-SRD
DIMENSIONS
3.10"
(79)
2.95"
(75)
1.12"
(28)
.56"
(14)
See pages 259-264 for a complete listing
of Frequently Ordered Products
Product Guide
211
Photocontrol Accessories
OA RC DC E RS IS NO GR I IENS F O R M A T I O N
Catalog
Number
Description
PHOTOCONTROL RECEPTACLES
Mounting adapter for connecting photocontrol to net. For pole,
wall and frame mounting. 14” x 14” gage wire. Line = black, Load = red,
Neutral = white. Each receptacle meets NEMA and ANSI standards.
DUR-103
With bracket and rotating cup with locknut.
PHOTOCONTROL TEST CAP
Lightweight black vinyl cap tests the working operation
of photocontrols during daylight hours. Completely
eliminates direct and reflected light, enabling quick and
easy testing. Not designed for use with hot sticks.
Affordably priced.
D-TEST CAP
1 - 1/2"
(37)
3 - 1/4"
(79)
PHOTOCONTROL DEMO BOX
Portable 120-volt test box.
Dimensions: 51/2 x 3 x 21/2 inches.
D-DEMO BOX
Color Chart
Photocontrol Recommendation Chart
DTL
SERIES
Type
Voltages
Available
Light
Sensor
Surge
Protection
Application
Typical
Electronic
D
Locking
120-277
MOV, 320 Joule
Roadway
Yes
DP
Locking
120-480
Cadmium
Sulphide
Silicon
MOV, 320 Joule
Roadway
Yes
DE
Locking
120-480
DX
Locking
DUX
DU
Locking,
UL Listed
Locking,
Part Night
Locking,
Diagnostic
Locking
DB
Button
120 and 208-277
DBE
Button
120 and 208-277
DA
Button
120 and 208-277
D7790
Locking
DPF
Locking,
Fail OFF
Locking,
Inverse Ratio
Locking,
Reverse
DPN
DD
DPR
DPO
212
Product Guide
MOV, 320 Joule
Roadway
Yes
120-480
Filtered
Silicon
Silicon
MOV, 320 Joule
C&I + Roadway
Yes
120-480
Silicon
MOV, 320 Joule
Yes
120-277
Silicon
MOV, 160 Joule
Where UL
is needed
Off-Roadway
120-277
Silicon
MOV, 160 Joule
Roadway
Yes
120 and 208-277
none
C&I or OEM
No
MOV, 190 Joule
Post top fixtures
Yes
MOV, 190 Joule
Utility post top
Yes
none
C&I or OEM
No
120-347
Cadmium
Sulphide
Cadmium
Sulphide
Filtered
Silicon
Cadmium
Sulphide
Silicon
120-277
Yes
MOV, 190 Joule Roadway or export
Yes
Silicon
MOV, 320 Joule
Off-Roadway
Yes
120-277
Silicon
MOV, 320 Joule
Roadway
Yes
120-277
Silicon
MOV, 320 Joule
OFF night, ON day
Yes
For more information, please visit our website,
www.americanelectriclighting.com
ANSI Color Codes
120V
240V
Multi-volt
350V
480V
Gray
Maroon
Dark Blue
Green
Yellow
POLES
Illustrated Samples ................................................214
RSA ...........................................................................218
Wind Map ................................................................215
RTA............................................................................219
Florida Wind Rating................................................216
RSAH ........................................................................220
General Information...............................................217
SSA ...........................................................................221
SSAH ........................................................................222
RSS ...........................................................................223
RTS............................................................................224
SSS ...........................................................................225
STS............................................................................226
STSH.........................................................................227
Pole Options ............................................................228
Aluminum Mounting Brackets .............................229
Steel Mounting Brackets ......................................230
RTF ............................................................................231
RTFDB.......................................................................232
SSF............................................................................233
RTCD.........................................................................234
RTCDDB ...................................................................235
STC............................................................................236
SPRTC.......................................................................237
SPRTS.......................................................................241
RTAU.........................................................................244
RTSU.........................................................................248
AMAW / SMAW......................................................250
AMAC / SMAC ........................................................252
SMAWL ....................................................................254
Options & Accessories..........................................256
American Electric Lighting™
I L L U S T R AT E D
S A M P L E S
There are several different pole types available throughout this section. Below are a few samples. Please contact your local American Electric
Lighting representative for more information.
Round Straight Aluminum
Round Straight Steel
18”
18”
Round Tapered Aluminum
Square Straight Steel
Square Straight Aluminum
18”
18”
Square Tapered Steel
18”
214
Product Guide
Round Tapered Fiberglass
For more information, please visit our website,
www.americanelectriclighting.com
Square Tapered Steel Hinge
Contact AEL for specific data.
W I N D
M A P
Product Guide
215
F L O R I D A
P O L E
W I N D
R AT I N G
SIDE-MOUNTED LOAD
Max WT/EPA Max WT/EPA
130mph Zone 150mph Zone
14.2 / 100
10.3 / 100
11.2 / 200
7.9 / 200
13.4 / 200
9.6 / 200
10.3 / 225
7.1 / 225
19.7 / 225
14.2 / 225
9.6 / 225
5.7 / 225
13.4 / 225
9.2 / 225
TENON-MOUNTED LOAD
Max WT/EPA Max WT/EPA
130mph Zone 150mph Zone
13.0 / 100
9.4 / 100
10.4 / 200
7.3 / 200
12.5 / 200
8.9 / 200
9.7 / 225
6.7 / 225
18.6 / 225
13.4 / 225
9.1 / 225
5.4 / 225
12.9 / 225
8.8 / 225
RTS
20
25
25
30
30
35
39
6-5B
7-0B
7-0F
8-0B
8-0F
9-5B
9-0F
Max. Wt.
that will be used
100
200
200
225
225
225
225
SSS
20
25
30
5G
5G
6G
100
100
100
DS330500W200
DS330500W250
DS330600W300
11.8 / 100
6.3 / 100
5.7 / 100
7.5 / 100
3.1 / 100
1.8 / 100
10.9 / 100
6.0 / 100
5.4 / 100
6.9 / 100
2.9 / 100
1.7 / 100
SSA
20
25
6G
6J
100
100
2000-60606N4
2000-60608N4
5.8
3.5
2.4
0
0
0
0
0
RTA
20
25
30
30
35
7E
8G
8G
10G
10G
100
200
200
225
225
1908-40705T4
2408-45806T4
2908-45806T4
2908-60106T4
3408-60106T4
7.5
8.8
5.6
11.4
8
5.3
6.2
3.6
7.7
5
7.2
8.5
5.5
11.2
7.9
5.1
6
3.7
7.6
4.9
Steel
Valmont No.
C H A R T
DS210650A200
DS210700A250
DS210700E250
DS210800A300
DS210800E300
DS210950A350
DS210900E389
Aluminum
1. Values are fastest-mile speeds at 33ft. (10m) above ground.
2. Linear interpolation between wind speed contours is acceptable.
3. Special wind regions require caution in application of wind
speed information. Contact your American Electric Lighting
representative for specific data.
216
Product Guide
For more information, please visit our website,
www.americanelectriclighting.com
Poles
General Information
Poles are available only in US
O R D E R I N G
I N F O R M AT I O N
Example: S S A 1 6 4 G D M 1 9 D D B A E L
Shaft Type
RTA
RSA
RSAH
SSA
SSAH
RTS
STS
STSH
RSS
SSS
SSF
RTF
RTFDB
SPRTC
STC
SPRTS
Nominal Shaft Base
Size/Wall
Thickness (in.)
Fixture Mounting Method
Round tapered aluminum
Round straight aluminum
4 C
0.125
Round straight aluminum hinged
5 E
0.156
Square straight aluminum
6 G
0.188
Square straight aluminum hinged
7 J
0.250
Round tapered steel
8 K
0.312
Square tapered steel
9 L
0.219
Square tapered steel hinged
10 P
0.375
Round straight steel
Square straight steel
Square straight fiberglass
Round tapered fiberglass
Nominal mounting height
Round tapered fiberglass
direct burial
8–50 feet Sportslighting poles
Round tapered concrete
up to 115'.
sportslighting
See website for specific
Square tapered concrete
information.
Round tapered steel
Option
See pages
Only open-top pole
256-257
accepts KKS
(4" square) and KKR
(4-1/2" round)
luminaires
Tenon Mounting
T20 2-3/8" O.D. (2" NPS)
T25 2-7/8" O.D. (2-1/2" NPS)
T30 3-1/2" O.D. (3" NPS)
T35 4" O.D. (3-1/2" NPS)
Drill Mounting
DM19 1 at 90°
DM28 2 at 180°
DM29 2 at 90°
DM39 3 at 90°
DM49 4 at 90°
DM32 3 at 120° (Round Poles)
PT
Finish
Architectural Colors1
Polyester Powder
Standard Colors
DDB Dark bronze
DWH White
DBL Black
BA Brushed
aluminum2
Class 1 Architectural
Anodize (RTA, RSA, SSA only)
ABL Black
ADB Dark bronze
ANA Natural
sportslighting
Notes:
1 Other colors available; please contact your local
American Electric Lighting representative
2 Aluminum poles only
Ordering Information:
Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then
add AEL after the last option.
All luminaire/pole assemblies require proper
evaluation to ensure that the structural integrity of the
assembly is not compromised when applied in
specific wind conditions. Therefore, the basis for pole
selection in this catalog is total weight and effective
projected area, EPA (ft2), shown on the individual pole
catalog pages. Determination of maximum EPA (ft2)
and weight loading must include all luminaires,
bracketry, signs, decoration, overhead wire or other
equipment that will be mounted to the subject pole.
Luminaire EPA (ft2) and weight data are found on their
respective product pages.
The total effective projected area of the luminaires
and brackets shall not exceed the EPA (ft2) listed for
the pole selected at a given wind velocity. Poles that
are to be located in areas of known abnormal
conditions will require special consideration. The
map on page 215 gives the wind velocities to be used
in determining luminaire pole compatibility.
Note: If during the pole warranty period of one year, the
product proves defective in material or workmanship, the
company shall correct, at its option, by repairing or replacing
at no charge to the purchaser, if the purchaser promptly
notifies the company. This warranty specifically excludes
fatigue failure or similar phenomena resulting from induced
vibration harmonic oscillation or resonance associated with
the movement of air currents around the product.
Pole Selection Procedure
Step 1. Select the luminaire and decide how many will be mounted per pole. Determine the Effective Projected
Area, EPA (ft2), which is given on the dimensional information table.
Step 2. Determine the appropriate mounting method for the luminaire. Options include arm, bracket or wall
mounting.
Step 3. Add together the EPA's (ft2) of the luminaire and arm/bracket. Multiply by number of fixtures to be
mounted on one pole.
Step 4. Consult the Wind Map on page 215 to determine the basic wind velocity for your area.
Step 5. Select the material (steel or aluminum) and shape (square or round) of the pole. Refer to the “Technical
Information” chart on the appropriate pole page.
A. Find the desired nominal mounting height in the second column.
B. Verify that the fixture weight does not exceed the maximum number listed.
C. Compare your total EPA (ft2) loading with the maximum EPA (ft2) value found in the wind speed column for your
area. Check that the equipment you are using will not exceed this value.
D. If both the weight and EPA (ft2) values do not exceed for which the pole is rated, you have selected the
correct pole. If, however, either one of those numbers exceeds the maximum rated values, compare the EPA (ft2)
and fixture weight loads to the next larger pole of the same mounting height.
CAUTION: This pole selection process is a guideline only. American Electric Lighting assumes no responsibility
for selection and recommends consultation with qualified individuals for verification of luminaire/pole assembly
selection.
Pole Data (RSA)
Shaft
Base
Size
Bolt
Circle
A
Bolt
Projection
B
Base
Square
C
Anchor
Bolt
Description
Warehouse
Anchor Bolt
Description
Template
Number
4"
4-1/2"
5"
6"
6-1/2"-8-1/4"
7-1/8"-8-3/8"
7-1/2"-9-1/2"
8-3/4"-10-1/4"
3-1/4"
3-1/4"
3-1/4"
3-1/2"
8-3/4"
8-1/2"
9-1/4"
10-1/4"
ABRSA-4
ABRSA-4-5
ABRSA-5
ABRSA-6
AB18-0
AB18-0
AB18-0
AB30-0
PJ50057
PJ50040
PJ50058
PJ50059
Product Guide
217
RSA
Anchor Base Poles
Round Straight Aluminum
P R O D U C T
O V E R V I E W
Intended Use
For 4-1/2” O.D., 8’ to 25’ mounting height.
Grounding – Ground lug located immediately inside handhole is
tapped for C|, -16 UNC ground bolt (not supplied).
Features:
Shaft – One-piece extruded 6063-T6 aluminum alloy with T6 temper.
Circumferential satin-brushed finish. 4-1/2" round straight tube is
uniform in cross-section down length of shaft.
Anchor Base – Cast from A356 aluminum alloy and heat treated to T6
temper. Base slipfits shaft, and they are joined together by continuous
circumferential welds at both top and bottom of anchor base to
provide maximum strength at area of critical stress.
Anchor Bolts – Top 12" is galvanized per ASTM A-153. Made of carbon
steel bar with a minimum-yield strength of 55,000 psi.
Handhole – Reinforced 3"x5" handhole is located 18" above base.
Cover and attachment hardware furnished.
Hardware – Stainless steel.
Top Cap – Cast-aluminum cap is provided for drill-mount poles.
Finish – Standard finish is brushed aluminum. Optional polyester
powder paint and anodized finishes available.
Bolt Covers – A356 nut covers included with anchor base unless
otherwise specified.
Ordering Information: See page 217
(Note: Poles are available only in U.S.)
INSTALLATION NOTES:
Installation requires grout to be packed under base
to ensure full contact with foundation. Factorysupplied templates must be used when setting
anchor bolts. American Electric Lighting will not
accept claim for incorrect anchorage placement due
to failure to use American Electric Lighting factory
templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping
must be removed immediately to prevent finish
damage.
218
Product Guide
Technical Information
EPA (ft2) with 1.3 gust
Catalog
Number
RSA 8 4C
RSA 8 4-5C
RSA 8 4-5G
RSA 10 4C
RSA 10 4-5C
RSA 10 4-5G
RSA 10 5C
RSA 12 4C
RSA 12 4-5C
RSA 12 4-5G
RSA 12 5C
RSA 12 5E
RSA 12 5G
RSA 14 4C
RSA 14 4-5C
RSA 14 4-5G
RSA 14 5C
RSA 14 5E
RSA 14 5G
RSA 16 4C
RSA 16 4-5C
RSA 16 4-5G
RSA 16 5C
RSA 16 5E
RSA 16 5G
RSA 16 6E
RSA 16 6G
RSA 18 4-5G
RSA 18 5C
RSA 18 5E
RSA 18 5G
RSA 18 6G
RSA 20 4-5G
RSA 20 5C
RSA 20 5E
RSA 20 5G
RSA 20 6E
RSA 20 6G
RSA 25 4-5G
RSA 25 6E
RSA 25 6G
RSA 30 6G
Nom.
Pole
Wall
Mount. Shaft Size Thick.
Ht. (ft.) (in. x in. x ft.) (in.)
8
8
8
10
10
10
10
12
12
12
12
12
12
14
14
14
14
14
14
16
16
16
16
16
16
16
16
18
18
18
18
18
20
20
20
20
20
20
25
25
25
30
4.0 x 8.0
4.5 x 8.0
4.5 x 8.0
4.0 x 10.0
4.5 x 10.0
4.5 x 10.0
5.0 x 10.0
4.0 x 12.0
4.5 x 12.0
4.5 x 12.0
5.0 x 12.0
5.0 x 12.0
5.0 x 12.0
4.0 x 14.0
4.5 x 14.0
4.5 x 14.0
5.0 x 14.0
5.0 x 14.0
5.0 x 14.0
4.0 x 16.0
4.5 x 16.0
4.5 x 16.0
5.0 x 16.0
5.0 x 16.0
5.0 x 16.0
6.0 x 16.0
6.0 x 16.0
4.5 x 18.0
5.0 x 18.0
5.0 x 18.0
5.0 x 18.0
6.0 x 18.0
4.5 x 20.0
5.0 x 20.0
5.0 x 20.0
5.0 x 20.0
6.0 x 20.0
6.0 x 20.0
4.5 x 25.0
6.0 x 25.0
6.0 x 25.0
6.0 x 30.0
0.125
0.125
0.188
0.125
0.125
0.188
0.125
0.125
0.125
0.188
0.125
0.156
0.188
0.125
0.125
0.188
0.125
0.156
0.188
0.125
0.125
0.188
0.125
0.156
0.188
0.156
0.188
0.188
0.125
0.156
0.188
0.188
0.188
0.125
0.156
0.188
0.156
0.188
0.188
0.156
0.188
0.188
80
mph
90
mph
100
mph
Max.
Wt.
Bolt
Circle
(in.)
11.2
14.6
21.8
8.2
10.6
16.3
13.6
6.0
8.1
12.7
10.3
13.2
16.2
4.1
5.8
9.7
7.8
10.3
12.8
2.8
4.2
7.5
5.9
8.0
10.1
13.6
16.8
5.7
4.3
6.1
8.0
13.9
4.3
3.0
4.7
6.4
9.3
11.8
1.3
5.2
7.1
3.5
8.6
11.3
17.0
6.1
8.1
12.6
10.6
4.3
6.0
9.7
8.0
10.3
12.6
2.8
4.2
7.3
6.0
8.0
9.9
1.6
2.8
5.5
4.4
6.1
7.8
10.6
13.0
4.0
3.1
4.6
6.8
10.7
2.9
2.1
3.4
4.8
7.1
9.1
—
3.8
5.3
2.4
6.8
9.1
13.7
4.7
6.5
10.1
8.5
3.2
4.8
7.7
6.3
8.2
10.1
1.9
3.3
5.8
4.7
6.3
7.9
1.0
2.1
4.3
3.4
4.8
6.1
8.4
10.4
3.1
2.4
3.5
4.7
8.5
2.1
1.5
2.6
3.6
5.5
7.1
—
2.8
4.0
1.6
125
175
225
100
133
175
150
110
80
185
150
200
225
75
60
190
100
125
150
150
50
155
175
190
200
225
245
123
150
175
225
225
95
150
150
150
175
200
100
150
150
200
6-1/2-8-1/4
7-1/8-8-3/8
7-1/8-8-3/8
6-1/2-8-1/4
7-1/8-8-3/8
7-1/8-8-3/8
7-1/2-9-1/2
6-1/2-8-1/4
7-1/8-8-3/8
7-1/8-8-3/8
7-1/2-9-1/2
7-1/2-9-1/2
7-1/2-9-1/2
6-1/2-8-1/4
7-1/8-8-3/8
7-1/8-8-3/8
7-1/2-9-1/2
7-1/2-9-1/2
7-1/2-9-1/2
6-1/2-8-1/2
7-1/8-8-3/8
7-1/8-8-3/8
7-1/2-9-1/2
7-1/2-9-1/2
7-1/2-9-1/2
8-3/4-10-1/4
8-3/4-10-1/4
7-1/8-8-3/8
7-1/2-9-1/2
7-1/2-9-1/2
7-1/2-9-1/2
8-3/4-10-1/4
7-1/8-8-3/8
7-1/2-9-1/2
7-1/2-9-1/2
7-1/2-9-1/2
8-3/4-10-1/4
8-3/4-10-1/4
7-1/8-8-3/8
8-3/4-10-1/4
8-3/4-10-1/4
8-3/4-10-1/4
For more information, please visit our website,
www.americanelectriclighting.com
Bolt
Approx.
Size
Ship Wt.
(in. x in. x in.) (lbs.)
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 30 x 3
22
30
38
26
34
43
36
30
38
50
36
44
53
35
42
56
39
47
56
38
46
62
46
53
60
53
78
68
48
58
68
86
74
54
68
82
95
110
89
108
128
146
RTA
Anchor Based Poles
Round Tapered Aluminum
P R O D U C T
O V E R V I E W
Intended Use
For 20’ to 40’ mounting height.
Grounding – A ground lug located immediately inside the handhole is
tapped round bolt (by others).
Features
Shaft – The shaft is spun tapered from seamless 6063 alloy aluminum
tubing and is heat treated to produce a T6 temper. The shaft is cone
tapered to the butt diameter.
Handhole – A nominal 3"x5" or 4"x6" reinforced flushed covered
handhole is centered 18" above the base.
Hardware – All screws, nuts and bolts are made of stainless steel.
Anchor Base – Cast from A356 alloy aluminum, the anchor base is
heat treated to a T6 condition. The anchor base telescopes the pole
shaft and is circumferentially welded top and bottom.
Top Cap – Cast-aluminum cap is provided for drill mount poles.
Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of steel rod
having a minimum yield strength of 55,000 PSI.
Bolt Covers – A356 nut covers shall be included with each anchor
base unless otherwise specified.
Finish – Standard finish is brushed aluminum. Optional polyester
powder paint and anodized finishes available.
Ordering Information: See page 217
(Note: Poles are available only in U.S.)
Technical Information
EPA (ft2) with 1.3 gust
Catalog
Number
RTA 20 5C
RTA 20 5G
RTA 20 6G
RTA 20 7E
RTA 25 6E
RTA 25 7E
RTA 25 8E
RTA 25 8G
RTA 30 7E
RTA 30 8E
RTA 30 8G
RTA 30 10G
RTA 35 8E
RTA 35 8G
RTA 35 8J
RTA 35 10G
RTA 39 8G
RTA 39 8J
RTA 39 10G
RTA 39 10J
Nom.
Pole
Wall
Mount Shaft Size Thickness 80
Ht. (ft.) (in. x in. x ft.)
(in.)
mph
20
20
20
20
25
25
25
25
30
30
30
30
35
35
35
35
39
39
39
39
5 x 3 x 19’8”
5 x 3 x 19’8”
6 x 4 x 19’8”
7 x 4 x 19’8”
6 x 4 x 24’ 8”
7 x 4 x 24’8”
8 x 4.5 x 24’ 8”
8 x 4.5 x 24’ 8”
7 x 4 x 29’8”
8 x 4.5 x 29’8”
8 x 4.5 x 29’8”
10 x 6 x 29’8”
8 x 4.5 x 34’8”
8 x 4.5 x 34’8”
8 x 4.5 x 34’8”
10 x 6 x 34’8”
8 x 4.5 x 38’8”
8 x 4.5 x 38’8”
10 x 6 x 38’8”
10 x 6 x 38’8”
0.125
0.188
0.188
0.156
0.156
0.156
0.156
0.188
0.156
0.156
0.188
0.188
0.156
0.188
0.250
0.188
0.188
0.250
0.188
0.250
3.9
7.4
12.2
15.0
5.3
9.5
14.2
18.0
5.5
9.4
12.4
23.8
5.8
8.3
12.9
17.9
5.6
9.7
14.2
20.4
90
mph
100
mph
Max.
wt.
2.5
5.2
9.2
11.4
3.6
7.0
10.9
13.8
3.8
7.0
9.4
18.3
4.1
6.0
9.7
13.6
3.9
7.1
10.5
15.5
1.6
3.8
7.2
9.0
2.6
5.4
8.5
10.9
2.7
5.3
7.3
14.3
2.9
4.5
7.5
10.4
2.7
5.4
7.8
11.9
100
100
214
256
114
162
220
261
111
151
179
377
119
141
183
295
122
158
253
300
Approx.
Bolt Circle
Bolt Size Ship Wt.
(in.)
(in. x in. x in.) (lbs.)
7-1/2-9-1/2
7-1/2-9-1/2
9–10
9-7/8-11-1/4
9–10
9-7/8-11-1/4
11–12
11–12
9-7/8-11-1/4
11–12
11–12
14-1/4-16-1/4
11–12
11–12
11–12
14-1/4-16-1/4
11–12
11–12
14-1/4-16-1/4
14-1/2-16
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 30 x 3
1 x 36 x 4
3/4 x 30 x 3
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 40 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 40 x 4
1 x 36 x 4
1 x 36 x 4
1 x 40 x 4
1-1/4 x 48 x 5
62
72
107
103
106
120
130
153
135
150
175
235
185
220
251
268
250
280
295
373
INSTALLATION NOTES:
Installation requires grout to be packed under base to
ensure full contact with foundation. Factory-supplied
templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for
incorrect anchorage placement due to failure to use
American Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping
must be removed immediately to prevent finish
damage.
Notes:
1
2
3
4
Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)
Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°
Options: See page 256-257
Brackets: See page 228-229
Pole Data
Shaft
Base
Size
Bolt
Circle
A
Bolt
Projection
B
Base
Square
C
Anchor
Bolt
Description
Warehouse
Anchor Bolt
Description
Template
Number
5"
6"
7"
8"
10"G
10"J
7-1/2"–9-1/2"
9"–10"
9-7/8"–11-1/4"
11"-12"
14-1/4"–16-1/4"
14-1/2"–16"
3-1/4"
3-1/2"
4-1/8"
4-1/4"
4-1/2"
5"
9-1/4"
10"
10-1/2"
11-1/2"
14-1/2"
14-1/2"
ABRTA-5
ABRTA-6
ABRTA-7
ABRTA-8
ABRTA-10G
ABRTA-10J
AB18-0
AB30-0
AB36-0
AB36-0
N/A
N/A
PJ50032
PJ50033
PJ50034
PJ50035
PJ50036
PJ50063z
18”
(45.7cm)
Product Guide
219
RSAH
Anchor Base Poles
Round Straight Aluminum, Hinged
P R O D U C T
O V E R V I E W
Intended Use
For 10’ to 20’ mounting height.
steel hex head bolts which attach to stainless steel inserts cast into
the aluminum base. A cast-aluminum two-piece cover is included.
Features
Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of carbon
steel bar having a minimum-yield strength of 55,000 PSI.
Shaft – One-piece extruded 6063 aluminum alloy with a T6 temper.
Circumferential satin-brushed finish. The round, straight tube is
uniform in cross-section down the length of the shaft.
Handhole – Available as an option, and located 90o to the right of the
hinge.
Hinged Anchor Base – Cast from A356 aluminum alloy, the anchor
base is heat treated to a T6 temper. The shaft inserts into the tilting
section of the hinged base and is joined together by continuous
circumferential welds at the outside top and inside bottom. The tilting
and anchored sections of the hinged base are joined by a 3/4"
diameter solid aluminum pivot rod. The tilting section of the hinged
base is held in a vertical position by three 1/2"-13 x 2 1/2" stainless
Hardware – Stainless steel.
Top Cap – Cast-aluminum cap is provided for drill mount poles.
Finish – Standard finish is brushed aluminum. Optional polyester
powder painted and anodized finishes available.
Ordering Information: See page 217
(Note: Poles are available only in U.S.)
Technical Information
EPA (ft2) with 1.3 gust
INSTALLATION NOTES:
Catalog
Number
Installation requires grout to be packed under base to
ensure full contact with foundation. Factory-supplied
templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for
incorrect anchorage placement due to failure to use
American Electric Lighting factory templates.
RSAH 10 4C
RSAH 14 4C
RSAH 14 5E
RSAH 16 4C
RSAH 16 5C
RSAH 16 6E
RSAH 18 5C
RSAH 18 5G
RSAH 20 5C
RSAH 20 5G
RSAH 20 6G
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping
must be removed immediately to prevent finish
damage.
Nom.
Pole
Wall
Mount. Shaft Size Thick.
Ht. (ft.) (in. x in. x ft.) (in.)
10
14
14
16
16
16
18
18
20
20
20
4 x 4 x 10
4 x 4 x 14
5 x 5 x 14
4 x 4 x 16
5 x 5 x 16
6 x 6 x 16
5 x 5 x 18
5 x 5 x 18
5 x 5 x 20
5 x 5 x 20
6 x 6 x 20
0.125
0.125
0.156
0.125
0.125
0.156
0.125
0.188
0.125
0.188
0.188
80
mph
90
mph
100
mph
Max.
Wt.
Bolt
Circle
(in.)
8.2
4.4
10.6
3.1
6.2
13.8
4.5
8.2
3.2
6.4
11.7
6.1
3.0
8.2
1.9
4.7
10.7
3.3
6.2
2.2
4.8
9.0
4.7
2.1
6.5
1.2
3.6
8.5
2.5
4.9
1.6
3.7
7.1
100
100
100
100
100
100
130
130
130
130
130
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
Bolt
Approx.
Size
Ship Wt.
(in. x in. x in.) (lbs)
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 30 x 3
43
50
66
54
60
88
65
90
69
97
110
C
Notes:
A
1
2
3
4
Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)
Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°
Options: See page 256-257
Brackets: See page 228-229
Pole Data
Tapped 3/8” - 16 for ground connector
Two-piece
cast-aluminum cover
220
Product Guide
Shaft
Base
Size
Bolt
Circle
A
Bolt
Projection
B
Base
Square
C
Anchor
Bolt
Description
Warehouse
Anchor Bolt
Description
Template
Number
4"
5"
6"
8-1/2"–10"
8-1/2"–10"
8-1/2"–10"
3-1/2"
3-1/2"
3-1/2"
12-5/8"
12-5/8"
12-5/8"
ABRSAH-4
ABRSAH-5
ABRSAH-6
AB18-0
AB18-0
AB30-0
PJ50060
PJ50061
PJ50062
For more information, please visit our website,
www.americanelectriclighting.com
SSA
Anchor Base Poles
Square Straight Aluminum
P R O D U C T
O V E R V I E W
Intended Use
For 4’, 5’ or 6’ shaft width, 8’ to 30’ mounting height.
Grounding – Ground lug located immediately inside handhole is
tapped for 3/8"-16 UNC grounding bolt (by others).
Features
Handhole – Rectangular reinforced handhole having nominal
dimensions 2" x 4" (4" sq.) or 2-1/2” x 4" (5" or 6" sq.). Handhole cover
plate made from aluminum alloy with attachment hardware provided.
Shaft – Square, non-tapered shaft made from extruded 6063-T6 or
6061-T6 aluminum alloy Shaft width is 4, 5 or 6 inches. Wall thickness
is .125, .188 or .250, depending on mounting height and loading
requirements.
Anchor Base – Cast from 356-T6 aluminum alloy. Anchor bolt holes
are recessed and covered by aluminum caps.
Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of 3/4" or 1"
diameter steel rod having minimum-yield strength of 55,000 psi.
Hardware – All screws, nuts and bolts are made of stainless steel.
Top Cap – Weatherproof, cast-aluminum cap is provided for drill
mount poles.
Finish – Brushed aluminum is standard; optional polyester powder
paint and anodized finishes available.
Bolt Covers – Nut covers included with each anchor base.
Ordering Information: See page 217
(Note: Poles are available only in U.S.)
Technical Information
EPA (ft ) with 1.3 gust
2
Catalog
Number
SSA 8 4C
SSA 10 4C
SSA 12 4C
SSA 14 4C
SSA 15 4C
SSA 16 4C
SSA 16 4G
SSA 16 5G
SSA 18 4C
SSA 18 4G
SSA 18 5G
SSA 20 4C
SSA 20 4G
SSA 20 5G
SSA 20 6G
SSA 20 6J
SSA 25 5G
SSA 25 6G
SSA 25 6J
SSA 30 6G
SSA 30 6J
SSA 32 6J
SSA 35 6J
Nom.
Pole
Wall
mount. Shaft Size Thick.
ht. (ft.) (in. x in. x ft.) (in.)
8
10
12
14
15
16
16
16
18
18
18
20
20
20
20
20
25
25
25
30
30
32
35
4.0 x 8.0
4.0 x 10.0
4.0 x 12.0
4.0 x 14.0
4.0 x 15.0
4.0 x 16.0
4.0 x 16.0
5.0 x 16.0
4.0 x 18.0
4.0 x 18.0
5.0 x 18.0
4.0 x 20.0
4.0 x 20.0
5.0 x 20.0
6.0 x 20.0
6.0 x 20.0
5.0 x 25.0
6.0 x 25.0
6.0 x 25.0
6.0 x 30.0
6.0 x 30.0
6.0 x 32.0
6.0 x 35.0
0.125
0.125
0.125
0.125
0.125
0.125
0.188
0.188
0.125
0.188
0.188
0.125
0.188
0.188
0.188
0.250
0.188
0.188
0.250
0.188
0.250
0.250
0.250
80
mph
90
mph
100
mph
Max.
wt.
Bolt
Circle
(in.)
16.5
11.5
12.4
9.3
8.0
6.9
11.8
15.0
4.9
9.2
16.8
3.3
7.0
13.6
22.0
30.4
7.2
13.2
19.7
7.0
12.2
9.7
6.4
12.6
8.6
9.2
6.7
5.6
4.7
8.5
11.1
3.0
6.4
12.2
1.7
4.6
9.5
15.9
22.6
4.2
8.6
13.8
3.4
7.5
5.4
2.6
9.9
6.5
6.9
4.8
3.9
3.1
6.2
7.5
1.7
4.4
8.9
0.5
2.9
6.6
11.6
17.0
2.0
5.4
9.5
0.8
4.1
2.3
—
300
230
160
120
100
90
130
280
70
100
230
40
80
180
230
300
110
180
250
130
170
160
200
8-1/2-9-5/8
8-1/2-9-5/8
8-1/2-9-5/8
8-1/2-9-5/8
8-1/2-9-5/8
8-1/2-9-5/8
8-1/2-9-5/8
10-1/2-11-1/2
8-1/2-9-5/8
8-1/2-9-5/8
10-1/2-11-1/2
8-1/2-9-5/8
8-1/2-9-5/8
10-1/2-11-1/2
12-13
12-13
10-1/2-11-1/2
12-13
12-13
12-13
12-13
12-13
12-13
Bolt
Approx.
Size
ship wt.
(in. x in. x in.) (lbs.)
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 30 x 3
1 x 36 x 4
1 x 36 x 4
3/4 x 30 x 3
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
32
37
40
50
52
54
74
83
57
80
91
62
85
107
155
202
130
180
224
210
258
272
294
INSTALLATION NOTES:
Installation requires grout to be packed under base to
ensure full contact with foundation. Factory-supplied
templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for
incorrect anchorage placement due to failure to use
American Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping
must be removed immediately to prevent finish
damage.
A
Tapered 3/4” for
ground connector
C
Notes:
1
2
3
4
Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)
Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°
Options: See page 256-257
Brackets: See page 228-229
Pole Data
ShaftBolt
Base
Size
Bolt
Circle
A
Base
Projection
B
Anchor
Square
C
Warehouse
Bolt
Description
Anchor Bolt
Description
Template
Number
4"C
4"G
5"
6"
8-1/2–9-5/8"
8-1/2–9-5/8"
10-1/2–11-1/2"
12"-13"
3-1/8"
3-1/8"
3-1/4"
4"
9-15/16"
9-15/16"
11-9/16"
12-1/4"
ABSSA-4C
ABSSA-4G
ABSSA-5
ABSSA-6
AB18-0
AB30-0
AB30-0
AB36-0
PJ50045
PJ50045
PJ50046
PJ50044
Product Guide
221
SSAH
Anchor Base Poles
Square Straight Aluminum, Hinged
P R O D U C T
O V E R V I E W
Intended Use
stainless steel inserts cast into the aluminum base. A cast-aluminum
two-piece cover is included.
For 4’, 5’ or 6’ shaft width, 10’ to 20’ mounting height.
Features
Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of 3/4”
diameter steel rod having minimum-yield strength of 55,000 psi.
Shaft – Square, non-tapered shaft made from extruded 6063-T6
aluminum alloy. Shaft width is 4 or 5 inches. Wall thickness is .125 or
.188 depending on mounting height and loading requirements.
Handhole – Available as an option, and located 90o to the right of the
hinge.
Hinged Anchor Base – Cast from A356 aluminum alloy and heat
treated to a T6 temper. The shaft inserts into the tilting section of the
hinged base and is joined together by continuous circumferential
welds at the outside top and inside bottom. The tilting and anchored
sections of the hinged base is held in a vertical position by three
1/2"–13 x 2-1/2" stainless steel hex head bolts which attach to
Hardware – All screws, nuts and bolts are made of stainless steel.
Top Cap – Weatherproof, cast-aluminum cap is provided for drill
mount poles.
Finish – Brushed aluminum is standard; optional polyester powder
paint and anodized finishes available.
Ordering Information: See page 217
(Note: Poles are available only in U.S.)
Technical Information
EPA (ft2) with 1.3 gust
INSTALLATION NOTES:
Installation requires grout to be packed under base to
ensure full contact with foundation. Factory-supplied
templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for
incorrect anchorage placement due to failure to use
American Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping
must be removed immediately to prevent finish
damage.
Catalog
Number
SSAH 10 4C
SSAH 12 4C
SSAH 14 4C
SSAH 15 4C
SSAH 16 4C
SSAH 16 4G
SSAH 18 4C
SSAH 18 4G
SSAH 18 5G
SSAH 20 4G
SSAH 20 5G
Nom.
Pole
Wall
Mount. Shaft Size Thick.
Ht. (ft.) (in. x in. x ft.) (in.)
10
12
14
15
16
16
18
18
18
20
20
4 x 4 x 10
4 x 4 x 12
4 x 4 x 14
4 x 4 x 15
4 x 4 x 16
4 x 4 x 16
4 x 4 x 18
4 x 4 x 18
5 x 5 x 18
4 x 4 x 20
5 x 5 x 20
0.125
0.125
0.125
0.125
0.125
0.188
0.125
0.188
0.188
0.188
0.188
80
mph
90
mph
100
mph
Max.
Wt.
Bolt
Circle
(in.)
13.1
9.6
7.0
6.0
5.0
8.9
3.4
6.8
12.6
5.0
9.9
9.9
7.0
4.9
4.0
3.2
6.2
1.8
4.5
8.8
3.0
6.6
7.5
5.1
3.3
2.6
1.9
4.3
0.7
2.9
6.1
1.6
4.2
100
100
100
100
100
150
100
100
150
150
175
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
8-1/2-10
9-5/16-10
8-1/2-10
9-5/16-10
Bolt
Approx.
Size
Ship Wt.
(in. x in. x in.) (lbs.)
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 18 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 30 x 3
48
53
57
60
62
86
67
93
108
100
117
Notes:
Two-piece, castaluminum cover
1
2
3
4
Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)
Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°
Options: See page 256-257
Brackets: See page 228-229
Pole Data
222
Product Guide
Shaft
Base
Size
Bolt
Circle
A
Bolt
Projection
B
Base
Square
C
Anchor
Bolt
Description
Warehouse
Anchor Bolt
Description
Template
Number
4C"
4G"
5"
8-1/2"–10"
8-1/2"–10"
9-5/16"–10"
3-1/2"
3-1/2"
3-1/2"
11-11/16"
11-11/16"
11-11/16"
ABSSAH-4C
ABSSAH-4G
ABSSAH-5
AB18-0
AB30-0
AB30-0
PJ50055
PJ50055
PJ50056
For more information, please visit our website,
www.americanelectriclighting.com
RSS
Anchor Base Poles
Round Straight Steel
P R O D U C T
Intended Use
O V E R V I E W
Anchor Bolts – Top 12" is galvanized per ASTM A-153. Made of carbon
steel bar with minimum-yield strength of 55,000 psi.
For 4-1/2” O.D., 8’ to 30’ mounting height.
Grounding – Nut holder located immediately inside handhole is
provided with 1/2-13 UNC ground bolt and nut.
Features
Handhole – Nominal 3"x5" handhole is located 18" above base. Cover
and attachment hardware provided.
Shaft – Weldable grade A500 or A513 carbon steel tubing with minimum
yield of 46,000 or 42,000 psi. Uniform wall thickness of .120". Shafts are
one-piece construction with a full longitudinal weld. The round, straight
tube is uniform in cross-section down length of shaft.
Hardware – Fasteners are high-strength galvanized zinc-plated or
stainless steel.
Top Cap – Plastic cap is provided for drill mount poles.
Anchor Base – Fabricated from carbon steel plate (ASTM A-36). 3/4"
thickness. Base plate and shaft are circumferentially welded at both top
and bottom to provide maximum strength at area of critical stress.
Finish – Dark bronze polyester powder paint (DDB) standard; optional
polyester powder paint finishes available.
Base Cover – Full-base cover finished to match pole.
Ordering Information: See page 217 (Note: Poles are available only in U.S.)
Technical Information
EPA (ft2) with 1.3 gust
Catalog
Number
RSS 8 4-5B
RSS 8 4-5B
RSS 10 3B
RSS 10 4B
RSS 10 4-5B
RSS 12 3B
RSS 12 4B
RSS 12 4-5B
RSS 14 3B
RSS 14 4B
RSS 14 4-5B
RSS 15 4-5B
RSS 16 3B
RSS 16 4B
RSS 16 4-5B
RSS 18 3B
RSS 18 4B
RSS 18 4-5B
RSS 20 3B
RSS 20 4B
RSS 20 4-5B
RSS 20 5B
RSS 22 4-5B
RSS 25 4B
RSS 25 4-5B
RSS 25 5B
RSS 30 4-5B
RSS 30 5B
Nom.
Pole
Wall
Mount. Shaft Size Thick.
Ht. (ft.) (in. x in. x ft.) (in.)
8
8
10
10
10
12
12
12
14
14
14
15
16
16
16
18
18
18
20
20
20
20
22
25
25
25
30
30
4.5 x 8.0
4.5 x 8.0
3.0 x 10.0
4.0 x 10.0
4.5 x 10.0
3.0 x 12.0
4.0 x 12.0
4.5 x 12.0
3.0 x 14.0
4.0 x 14.0
4.5 x 14.0
4.5 x 15.0
3.0 x 16.0
4.0 x 16.0
4.5 x 16.0
3.0 x 18.0
4.0 x 18.0
4.5 x 18.0
3.0 x 20.0
4.0 x 20.0
4.5 x 20.0
5.0 x 20.0
4.5 x 22.0
4.0 x 25.0
4.0 x 25.0
5.0 x 25.0
4.5 x 30.0
5.0 x 30.0
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
80
mph
Max.
Wt.
90
mph
Max.
Wt.
100
mph
Max.
Wt.
24.5
24.5
10
19.1
24.5
7.7
15.0
19.8
6.0
12.2
16.2
13.1
4.6
9.6
13.1
3.4
7.6
10.5
2.4
6.0
8.5
11.75
4.8
2.85
4.8
7.25
2.3
4.2
615
615
250
480
615
195
390
495
175
305
405
330
125
250
330
90
190
265
100
150
215
300
130
100
130
180
80
150
19.5
19.5
7.7
15.0
19.5
5.8
11.8
15.7
4.4
9.4
12.8
10.2
3.2
7.4
10.2
2.3
5.7
8.2
1.4
4.45
6.6
9.1
3.6
1.95
3.6
5.5
1.5
3
490
490
190
375
490
145
300
395
130
250
320
265
100
185
265
60
180
210
75
150
165
230
90
75
90
150
75
125
15.8
15.8
6.0
12.2
15.8
4.4
9.5
12.7
3.3
7.6
10.3
8.2
2.3
5.9
8.2
1.4
4.5
6.5
—
3.45
5.2
7.25
2.7
1.35
2.7
4.25
1.0
2.25
395
395
175
305
395
130
240
320
90
195
260
205
60
150
205
70
130
165
—
125
130
180
90
75
90
150
60
100
Shaft
Base
size
Bolt
circle
A
Bolt
projection
B
Base
square
C
Anchor
Bolt
description
Warehouse
Anchor Bolt
description
Template
number
3
4"
4-1/2"
5"
8"
8"
8"
8"
3-1/4" x 3-1/2"
3-1/4" x 3-1/2"
3-1/4" x 3-1/2"
3-1/4" x 3-1/2"
8"
8"
8"
8"
ABRSS-4
ABRSS-4
ABRSS-4
ABRSS-4
AB18-0
AB18-0
AB18-0
AB18-0
PJ50041
PJ50041
PJ50041
PJ50041
1 Mounting Arrangement: (PT) Open Top (T20) 2-3/8" O.D. (2" NPS)
2 Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
3/4 x 18 x 3
55
55
55
70
75
60
80
85
70
90
95
96
80
100
105
90
110
115
100
120
130
145
134
145
145
180
185
210
C
Nut Holder
Handhole Cover
18”
INSTALLATION NOTES:
Pole Data
Notes:
Bolt
Bolt
Approx.
Circle
Size
Ship Wt.
(in.) (in. x in. x in.) (lbs.)
Installation requires grout to be packed under base to ensure full contact
with foundation. Factory-supplied templates must be used when setting
anchor bolts. American Electric Lighting will not accept claim for incorrect
anchorage placement due to failure to use American Electric Lighting
factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping must be removed
immediately to prevent finish damage.
3 Options: See page 256-257
4 Brackets: See page 228-229
Product Guide
223
RTS
Anchor Base Poles
Round Tapered Steel
P R O D U C T
O V E R V I E W
Intended Use
For 30’ to 50’ mounting height.
Grounding – Nut holder located immediately inside handhole rim is
provided with 1/2" – 13 UNC ground bolt and nut.
Features
Anchor Bolts – Fabricated from commercial-quality hot-rolled carbon
steel with minimum yield strength of 55,000 psi. Bolts have an "L" bend
on one end.
Shaft – Minimum weldable-grade (ASTM A-595 Grade A), hot-rolled,
commercial-quality carbon steel tubing with minimum yield of 55,000
psi. Uniform wall thickness of 11-gauge (0.1196") or 7-gauge (0.1793").
Shafts are constructed with full-length, longitudinal, high-frequency
resistance welds. Round in cross-section, having uniform taper of
approximately .14" per foot.
Hardware – Fasteners are high-strength galvanized zinc-plated or
stainless steel.
Top Cap – Weatherproof removable top cap provided with all drillmount poles.
Anchor Base – Fabricated from hot-rolled carbon steel plate that
conforms to ASTM A36.
Finish – Dark bronze polyester powder finish (DDB) standard; other
architectural colors available.
Handhole – Rectangular, reinforced handhole rim having nominal
dimensions of 3"x5" for shafts less than 6.25" base diameter and 4"x6.5"
for all other shafts. Steel cover with attachment screws included.
Handhole is located 18" above base.
Ordering Information:
See page 217
(Note: Poles are available only
in U.S.)
INSTALLATION NOTES:
Installation requires grout to be packed
under base to ensure full contact with
foundation. Factory-supplied templates
must be used when setting anchor
bolts. American Electric Lighting will
not accept claim for incorrect
anchorage placement due to failure to
use American Electric Lighting factory
templates.
Do not erect poles without having
fixtures installed.
If poles are stored outside, all
protective wrapping must be removed
immediately to prevent finish damage.
Base Cover – Full-base cover standard.
Technical Information
EPA (ft2) with 1.3 gust
Nom.
Pole
Wall
Mount. Shaft Size Thick.
Ht. (ft.) (in. x in. x ft.) (in.)
Catalog
Number
RTS 20 5-9B
RTS 20 6-5B
RTS 25 5-9B
RTS 25 7-0B
RTS 25 7-0F
RTS 30 6-6B
RTS 30 8-0B
RTS 30 8-0F
RTS 35 7-3B
RTS 35 8-5B
RTS 35 9-5B
RTS 39 7-8B
RTS 39 9-0B
RTS 39 9-0F
RTS 45 10-0B
RTS 45 10-0F
RTS 50 10-0B
RTS 50 10-0F
20
20
25
25
25
30
30
30
35
35
35
39
39
39
45
45
50
50
5.9 x 3.1 x 20
6.5 x 3.7 x 20
5.9 x 2.4 x 25
7.0 x 3.5 x 25
7.0 x 3.5 x 25
6.6 x 2.4 x 30
8.0 x 3.8 x 30
8.0 x 3.8 x 30
7.3 x 2.4 x 35
8.5 x 3.6 x 35
9.5 x 4.6 x 35
7.8 x 2.4 x 39
9.0 x 3.6 x 39
9.0 x 3.6 x 39
10.0 x 3.7 x 45
10.0 x 3.7 x 45
10.0 x 3.0 x 50
10.0 x 3.0 x 50
0.125
0.125
0.125
0.125
0.188
0.125
0.125
0.188
0.125
0.125
0.125
0.125
0.125
0.188
0.125
0.188
0.125
0.188
Gauge
80
mph
Max.
Wt.
90
mph
Max.
Wt.
100
mph
Max.
Wt.
11
11
11
11
7
11
11
7
11
11
11
11
11
7
11
7
11
7
19.3
24.2
12.5
20.3
28.5
11.7
18.9
27.5
11.2
18.9
23.2
10.7
17.2
26.1
17.4
25.5
13.2
20.5
482
605
312
507
713
292
473
550
280
472
580
267
430
654
435
639
330
512
15.1
19.3
9.9
16.2
22.5
9.3
14.9
21.6
8.9
15.1
18.2
8.5
13.5
20.6
13.5
20.2
10.6
16.5
377
482
247
405
563
232
373
542
222
377
455
212
338
517
338
505
265
412
12.2
15.6
8
13.1
18.2
7.5
12
17.5
7.1
12.2
14.5
6.6
10.8
16.7
10.6
16.3
8.3
13.6
305
390
200
327
455
187
300
439
177
305
363
165
270
419
265
409
208
340
Bolt
Bolt
Approx.
Circle
Size
Ship Wt.
(in.) in. x in. x in.) (lbs.)
9.0
9.5
9.0
10.0
10.0
9.5
11.0
11.0
10.5
11.5
13.0
11.0
12.5
12.5
13.5
13.5
13.5
13.5
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1-1/4 x 42 x 6
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1-1/4 x 42 x 6
1 x 36 x 4
1-1/4 x 42 x 6
1 x 36 x 4
1-1/4 x 42 x 6
140
160
155
200
280
200
265
380
250
315
370
285
355
515
450
650
475
680
Pole Data
Shaft
Base
Size
Bolt
Circle
A
Bolt
Projection
B
Base
Square
C
Anchor
Bolt
Description
Warehouse
Anchor Bolt
Description
3-1/2"–4-1/4"
3-1/2"–4-1/4"
3-1/2"–4-1/4"
3-3/4"–4-1/2"
3-1/2"–4-1/4"
3-1/2"–4-1/4"
4-1/2–5-1/4"
3-1/2"–4-1/4"
3-3/4"–4-1/2"
3-3/4"–4-1/2"
3-3/4"–4-1/2"
3-3/4"–4-1/2"
4-1/2"–5-1/4"
3-3/4"–4-1/2"
4-1/2"–5-1/4"
10"
10-1/2"
10-7/8"
10-7/8"
10-1/2"
11-1/2"
11-1/2"
11-1/4"
12"
13"
11-1/2"
12-3/8"
12-3/8"
14"
14"
ABRTS-5-9B
ABRTS-6-5B
ABRTS-7-0B
ABRTS-7-0F
ABRTS-6-6B
ABRTS-8-0B
ABRTS-8-0F
ABRTS-7-3B
ABRTS-8-5B
ABRTS-9-5B
ABRTS-7-8B
ABRTS-9-0B
ABRTS-9-0F
ABRTS-10-B
ABRTS-10-F
AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
N/A
AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
N/A
AB36-0
N/A
Template
Number
A
C
Notes:
1 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D.
(2" NPS)
2 Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures
at 180°
3 Options: See page 256-257
4 Brackets: See page 228-229
224
Product Guide
5.9" B
6.5" B
7.0" B
7.0" F
6.6" B
8.0" B
8.0" F
7.3" B
8.5" B
9.5" B
7.8" B
9.0" B
9.0" F
10.0" B
10.0" F
9"
9.5"
10"
10"
9.5"
11"
11"
10.5"
11.5"
13"
11"
12.5"
12.5"
13.5"
13.5"
For more information, please visit our website,
www.americanelectriclighting.com
PJ50075
PJ50074
PJ50077
PJ50076
PJ50078
PJ50079
PJ50080
PJ50081
PJ50082
PJ50083
PJ50084
PJ50085
PJ50086
PJ50087
PJ50088
SSS
Anchor Base Poles
Square Straight Steel
P R O D U C T
O V E R V I E W
Intended Use
For 4”, 5” or 6” shaft width, 10’ to 40’ mounting height.
diameter steel rod having a minimum-yield strength of 55,000 psi.
Grounding – Nut holder located immediately inside handhole rim is
provided with a 1/2" x13 UNC ground bolt and nut.
Features
Handhole – Rectangular, reinforced handhole rim having nominal
dimensions of 3"x5" for all shafts. Included is steel cover with
attachment screws.
Shaft – Weldable-grade, hot-rolled, commercial-quality carbon steel
tubing with a minimum yield of 55,000 psi (11-gauge), 50,000 psi (7gauge). Uniform wall thickness of .125" or .188". Shaft is one piece with
a longitudinal, electric, resistance weld. Uniformly square in crosssection with flat sides, small corner radii and excellent torsional
qualities. Available shaft widths are 4, 5 and 6 inches.
Hardware – Fasteners are high-strength, galvanized zinc-plated or
stainless steel.
Top Cap – Weatherproof, high-strength plastic cap is provided for drill
mount poles.
Anchor Base – Fabricated from hot-rolled carbon steel plate that
meets or exceeds a minimum-yield strength of 36,000 psi. The anchor
base is provided with slotted holes.
Finish – Dark bronze polyester powder paint (DDB) standard; optional
polyester powder paint finishes available.
Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of C|v" or 1"
Base Cover – Full-base cover finished to match pole.
Ordering Information: See page 217 (Note: Poles are available only in U.S.)
INSTALLATION NOTES:
Technical Information
EPA (ft2) with 1.3 gust
Nom.
Pole
Wall
Catalog
Mount. Shaft Size
Thick.
Number
Ht. (ft.) (in. x in. x ft.)
(in.)
Bolt
Bolt
Approx.
Circle
Size
Ship Wt.
80
Max.
90
Max.
100
Max.
Gauge
mph
Wt.
mph
Wt.
mph
Wt.
(in.) (in. x in. x in.) (lbs.)
SSS 10 4C
10
4.0 x 10.0
0.125
11
30.6
765
23.8
595
18.9
473
8–9
3/4 x 18 x 3
SSS 12 4C
12
4.0 x 12.0
0.125
11
24.4
610
18.8
470
14.8
370
8–9
3/4 x 18 x 3
75
90
SSS 14 4C
14
4.0 x 14.0
0.125
11
19.9
498
15.1
378
11.7
293
8–9
3/4 x 18 x 3
100
SSS 16 4C
16
4.0 x 16.0
0.125
11
15.9
398
11.8
295
8.9
223
8–9
3/4 x 18 x 3
115
SSS 18 4C
18
4.0 x 18.0
0.125
11
12.6
315
9.2
230
6.7
168
8–9
3/4 x 18 x 3
125
SSS 20 4C
20
4.0 x 20.0
0.125
11
9.6
240
6.7
167
4.5
150
8–9
3/4 x 18 x 3
140
SSS 20 4G
20
4.0 x 20.0
0.188
7
16.5
415
12.25
310
9.3
240
8–9
3/4 x 30 x 3
198
SSS 20 5C
20
5.0 x 20.0
0.125
11
17.7
443
12.7
343
9.4
235
10–12
1 x 36 x 4
185
SSS 20 5G
20
5.0 x 20.0
0.188
7
28.1
703
21.4
535
16.2
405
10–12
1 x 36 x 4
265
SSS 25 4C
25
4.0 x 25.0
0.125
11
4.8
150
2.6
100
1.0
50
8–9
3/4 x 18 x 3
170
SSS 25 4G
25
4.0 x 25.0
0.188
7
10.8
270
7.7
188
5.4
135
8–9
3/4 x 30 x 3
245
SSS 25 5C
25
5.0 x 25.0
0.125
11
9.8
245
6.3
157
3.7
150
10–12
1 x 36 x 4
225
SSS 25 5G
25
5.0 x 25.0
0.188
7
18.0
350
12.6
350
9.0
250
10–12
1 x 36 x 4
320
SSS 30 4G
30
4.0 x 30.0
0.188
7
6.4
160
4.0
100
2.3
58
8–9
3/4 x 30 x 3
295
SSS 30 5C
30
5.0 x 30.0
0.125
11
4.7
150
2.0
50
—
—
10–12
1 x 36 x 4
265
SSS 30 5G
30
5.0 x 30.0
0.188
7
10.7
267
6.7
167
3.9
100
10–12
1 x 36 x 4
380
SSS 30 6G
30
6.0 x 30.0
0.188
7
15.7
392
10.2
257
6.4
160
11–13
1 x 36 x 4
520
SSS 35 5G
35
5.0 x 35.0
0.188
7
5.9
150
2.5
100
—
—
10–12
1 x 36 x 4
440
SSS 35 6G
35
6.0 x 35.0
0.188
7
9.5
237
5.0
150
1.8
50
11–13
1 x 36 x 4
540
SSS 39 6G
39
6.0 x 39.0
0.188
7
5.1
128
1.3
33
—
—
11–13
1 x 36 x 4
605
Installation requires grout to be packed
under base to ensure full contact with
foundation. Factory-supplied templates
must be used when setting anchor
bolts. American Electric Lighting will
not accept claim for incorrect
anchorage placement due to failure to
use American Electric Lighting factory
templates.
Do not erect poles without having
fixtures installed.
If poles are stored outside, all
protective wrapping must be removed
immediately to prevent finish damage.
C
A
Pole Data
Shaft
Base
size
Bolt
Circle
A
Bolt
Projection
B
Base
Square
C
Anchor
Bolt
Description
Warehouse
Anchor Bolt
Description
Template
Number
4"C
4"G
5"
6"
8-1/2"
8-1/2"
10"–12"
11"–13"
2-3/4"–4"
2-3/4"–4"
3-3/8"–4"
3-3/8"–4"
8"
8"
11"
12-1/2"
ABSSS-4C
ABSSS-4G
ABSSS-5
ABSSS-6
AB18-0
AB30-0
AB36-0
AB36-0
PJ50004
PJ50004
PJ50010
PJ50011
Notes:
1 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D.
(2" NPS)
2 Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures
at 180°
3 Options: See page 256-257
4 Brackets: See page 228-229
Product Guide
225
STS
Anchor Base Poles
Square Tapered Steel
P R O D U C T
O V E R V I E W
Intended Use
For 20’ to 50’ mounting height.
Grounding – Nut holder located immediately inside handhole rim is
provided with a 1/2" – 13 UNC ground bolt and nut.
Features
Handhole – Rectangular, reinforced handhole rim having nominal
dimensions of 3"x5" for shafts less than 6.375" square and 4"x6.5" for all
other shafts. Steel cover with attachment screws included. Handhole
is located 18" above base.
Shaft – Minimum weldable-grade (ASTM A-595 Grade A) hot-rolled
commercial-quality carbon steel tubing with minimum yield of 55,000
psi. Uniform wall thickness of 11-gauge (0.1196") or 7-gauge (0.1793").
Shafts are constructed with full-length longitudinal high-frequency
resistance welds and are round in cross-section, having a uniform
taper of approximately .11" per foot.
Anchor Base – Fabricated from hot-rolled carbon steel plate that
conforms with ASTM A36.
Anchor Bolts – Fabricated from commercial-quality, hot-rolled carbon
steel with minimum-yield strength of 55,000 psi. Bolts have an "L" bend
on one end.
Ordering Information:
See page 217
(Note: Poles are available only
in U.S.)
Hardware – Fasteners are high-strength galvanized zinc-plated or
stainless steel.
Top Cap – Weatherproof, removable top cap provided with all drillmount poles.
Finish – Dark bronze polyester powder finish (DDB) standard; other
architectural colors available.
Base Cover – Full-base cover standard
Technical Information
EPA (ft2) with 1.3 gust
Nom.
Pole
Mount. Shaft Size
Ht. (ft.) (in. x in. x ft.)
Catalog
Number
Wall
Thick.
(in.) Gauge
80
mph
Max.
Wt.
90
mph
Max.
wt.
100
mph
Max.
Wt.
0.125
0.188
0.125
0.188
0.125
0.188
0.125
0.188
0.125
0.188
0.188
0.188
0.188
18.0
30.5
16.8
28.5
13.6
23.6
10.7
23.4
8.6
19.3
16.0
23.5
19.4
452
764
422
713
340
590
269
585
215
483
400
588
485
13.8
24.0
12.6
22.5
9.8
17.9
7.3
17.4
5.4
14.2
11.1
16.6
13.2
345
602
315
563
245
448
184
435
135
355
278
415
332
10.7
19.0
9.5
18.2
7.0
13.7
4.8
13.0
3.0
10.4
7.4
11.4
8.7
268
477
238
455
175
343
120
325
75
260
187
287
218
Bolt
Bolt
Approx.
Circle
Size
Ship W t.
(in.) (in. x in. x in.) (lbs.)
INSTALLATION NOTES:
Installation requires grout to be
packed under base to ensure full
contact with foundation. Factorysupplied templates must be used
when setting anchor bolts. American
Electric Lighting will not accept claim
for incorrect anchorage placement
due to failure to use American Electric
Lighting factory templates.
Do not erect poles without having
fixtures installed.
STS 20 5-2B
STS 20 5-5F
STS 25 6-0B
STS 25 6-4F
STS 30 6-4B
STS 30 6-4F
STS 35 6-8B
STS 35 7-1F
STS 39 7-1B
STS 39 7-1F
STS 45 7-8F
STS 45 8-7F
STS 50 8-8F
If poles are stored outside, all
protective wrapping must be removed
immediately to prevent finish damage.
20
20
25
25
30
30
35
35
39
39
45
45
50
5.25 x 3.05 x 20
5.50 x 3.30 x 20
6.00 x 3.25 x 25
6.41 x 3.66 x 25
6.41 x 3.11 x 30
6.41 x 3.11 x 30
6.81 x 2.96 x 35
7.13 x 3.28 x 35
7.18 x 2.92 x 39
7.13 x 2.87 x 39
7.88 x 2.93 x 45
8.75 x 3.80 x 45
8.81 x 3.31 x 50
11
7
11
7
11
7
11
7
11
7
7
7
7
10-3/4 1 x 36 x 4
11
1 x 36 x 4
12
1 x 36 x 4
12-1/2 1 x 36 x 4
12-1/2 1 x 36 x 4
12-1/2 1 x 36 x 4
13
1 x 36 x 4
13-1/2 1 x 36 x 4
13-1/2 1 x 36 x 4
13-1/2 1 x 36 x 4
14-1/2 1 x 36 x 4
15-3/4 1-1/4 x 42 x 6
16 1-1/4 x42 x 6
155
235
205
310
260
375
305
475
345
500
620
730
780
Notes:
1
2
3
4
A
Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)
Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°
Options: See page 256-257
Brackets: See page 228-229
Pole Data
18”
C
226
Product Guide
Shaft
Base
Size
Bolt
Circle
A
Bolt
Projection
B
Base
Square
C
Anchor
Bolt
Description
Warehouse
Anchor Bolt
Description
Template
Number
5.2" B
5.5" F
6.0" B
6.4" F
6.4" B
6.8" B
7.1" F
7.1" B
7.8" F
8.7" F
8.8" F
10-3/4"
11"
12"
12-1/2"
12-1/2"
13"
13-1/2"
13-1/2"
14-1/2"
15-3/4"
16"
3-1/2"–4-1/4"
3-3/4"–4-1/2"
3-1/2"–4-1/4"
4"–4-3/4"
3-1/2"–4-1/4"
3-1/2"–4-1/4"
4-1/4"–5"
3-1/2"–4-1/4"
4"–4-3/4"
4-3/4"–5-1/2"
4-1/2"–5-1/4"
10-3/4"
11"
11-1/2"
11-7/8"
11-7/8"
12-1/4"
12-5/8"
12-5/8"
13-3/8"
14-1/4"
15-1/2"
ABSTS-5-2B
ABSTS-5-5F
ABSTS-6-0B
ABSTS-6-4F
ABSTS-6-4B
ABSTS-6-8B
ABSTS-7-1F
ABSTS-7-1B
ABSTS-7-8F
ABSTS-8-7F
ABSTS-8-8F
AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
N/A
N/A
PJ50095
PJ50096
PJ50097
PJ50098
PJ50099
PJ50101
PJ50102
PJ50103
PJ50105
PJ50106
PJ50107
For more information, please visit our website,
www.americanelectriclighting.com
STSH
Anchor Base Poles
Square Tapered Steel Hinge
P R O D U C T
O V E R V I E W
Intended Use
Anchor Bolts – Fabricated from commercial-quality, hot-rolled carbon
steel with minimum-yield strength of 55,000 psi. Bolts have an "L" bend
on one end.
For 20’ to 39’ mounting height.
Features
Grounding – Nut holder located immediately inside handhole rim is
provided with a 1/2" – 13 UNC ground bolt and nut.
Shaft – Weldable-grade, hot-rolled, commercial-quality carbon steel
having a guaranteed minimum yield strength of 55,000 psi and is
supplied in 11-gauge (.1196") or 7-gauge (.1793") nominal thickness.
Pole is one-piece construction with full-length, longitudinal, highfrequency, electric-resistance weld. Shaft is square in cross section
having flat sides, radiused corners and uniform taper of
approximately 0.11 inches per foot of length (4-inch square poles are
not tapered).
Handhole – Rectangular, reinforced handhole rim having nominal
dimensions of 3" x 5" for shafts less than 6.375" square and 4" x 6.5" for
all other shafts. Steel cover with attachment screws included.
Handhole is located 18" above base.
Hardware – Fasteners are high-strength, galvanized zinc-plated or
stainless steel.
Top Cap – Weather-proof, removable top cap provided with all drillmount poles.
Hinge – The hinge includes a stainless steel hinge pin. A flexible
wiring guide is provided, passing through the hinge area for wiring
protection. Hinge is external.
Finish – Dark bronze polyester powder finish (DDB) standard; other
architectural colors available.
Anchor Base – Fabricated from hot-rolled carbon steel plate that
conforms with ASTM A36.
Base Cover – Full-base cover is provided.
Ordering Information: See page 217 (Note: Poles are available only in U.S.)
INSTALLATION NOTES:
Installation requires grout to be packed under
base to ensure full contact with foundation.
Factory-supplied templates must be used
when setting anchor bolts. American Electric
Lighting will not accept claim for incorrect
anchorage placement due to failure to use
American Electric Lighting factory templates.
Technical Information
EPA (ft ) with 1.3 gust
2
Catalog
Number
Nom.
Pole
Wall
Mount. Shaft Size Thick.
80 Max.
Ht. (ft.) (in. x in. x ft.) (in.) Gauge mph Wt.
STSH 20 4F
STSH 25 4B
STSH 25 6-4B
STSH 30 4F
STSH 30 6-4B
STSH 35 7-1B
STSH 35 7-1F
STSH 39 7-1F
20
25
25
30
30
35
35
39
4 x 4 x 20
4 x 4 x 25
6.41 x 3.63 x 25
4 x 4 x 30
6.41 x 3.08 x 30
7.18 x 2.88 x 35
7.13 x 2.87 x 35
7.13 x 2.87 x 39
0.188
0.125
0.125
0.188
0.125
0.125
0.188
0.188
7
11
11
7
11
11
7
7
11.6
7.1
18.0
4.0
12.5
7.1
22.0
19.5
217
160
254
120
230
160
155
110
90 Max.
mph Wt.
100
mph
Max.
Wt.
8.5
4.8
13.0
2.1
8.3
3.2
16.9
13.5
6.2
3.1
9.3
0.8
5.1
—
12.1
9.2
217
160
254
120
230
—
155
110
217
160
254
120
230
160
155
110
Bolt
Bolt
Approx.
Circle
Size
Ship Wt
(in.) (in. x in. x in.) (lbs)
8-1/2-10 3/4 x 18 x 3
8-1/2-10 3/4 x 18 x 3
12-1/2 1 x 36 x 4
8-1/2-10 3/4 x 18 x 3
12-1/2 1 x 36 x 4
13-1/2 1 x 36 x 4
13-1/2 1 x 36 x 4
13-1/2 1 x 36 x 4
300
370
355
435
440
540
700
740
Do not erect poles without having fixtures
installed.
If poles are stored outside, all protective
wrapping must be removed immediately to
prevent finish damage.
Notes:
1
2
3
4
External Hinge Detail
Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)
Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°
Options: See page 256-256
Brackets: See page 228-229
4.0" F
6.4" B
7.1" F
7.1" B
Bolt
Circle
A
Bolt
Projection
B
8-1/2"–10" 3-1/2"–4-1/4"
12-1/2" 3-3/4"–4-1/2"
13-1/2"
4"–4-3/4"
13-1/2" 3-1/2"–4-1/4"
Base
Square
C
Anchor
Bolt
description
Warehouse
Anchor Bolt
description
Template
Number
9-3/4"
11-7/8"
12-5/8"
12-5/8"
ABSTSH4F
ABSTSH6-4B
ABSTSH7-1F
ABSTSH7-1B
AB18-0
AB36-0
AB36-0
AB36-0
PJ50091
PJ50092
PJ50093
PJ50094
Winch Ordering
Family
Winch
Shaft size
Order nomenclature
STSH
WCH
4F
6-4B
7-1B
7-1F
STSHWCH 4F
STSHWCH 6-4B
STSHWCH 7-1B
STSHWCH 7-1F
Shroud
Wing
Protection
Bottom
C
Pole Data
Shaft
Base
Size
Hinge Pin
Top Assem
A
Bolt Slots
Winch Detail (accessory)
Removable
Product Guide
227
Pole Options
P R O D U C T
O V E R V I E W
Anchor Bolts
Horizontal Arm Bracket
Available in various sizes for use with American Electric Lighting poles. Set
includes hex nuts and washers. Anchor bolt is partially galvanized for exposed
threads per ASTM-A153. Bolts have minimum-yield strength rating of 55,000
psi, AASHTO M314 GR55. See
individual pole catalog pages
for anchor bolt sizes and
description.
Single or twin side-mounted horizontal arm brackets for additional
luminaires. Made from 2-3/8," pipe. Upright is 18" from pole; special arm
lengths may be available upon request. Arms are rated for luminaires up to
4.5 sq. ft. EPA and 100 lbs. per arm. When ordering, specify location in height
and feet above base of pole and orientation from the handhole.
Base Covers
Option
Two-piece, full-base cover. Four fasteners provided to secure pieces together.
Finished to match pole. Shipped separately. Standard with steel poles only.
H1-18A Aluminum
H1-18S Steel
HI-18F Fiberglass
HI-18C Concrete
Option
Pole
(Square)
Dimension
(Depth)
Dimension
SBC4
SBC5
SBC6
SSS 4"
SSS 5"
SSS 6"
8.75"
11.44"
13.5"
x 5.8"
x 6.4"
x 4"
Festoon Outlets
Provision provided for mounting duplex outlet. When ordering, specify location
in height and feet above base of pole and orientation from the handhole.
Description
FDL
FGL
Weight
(lbs.)
.43
.50
.45
.55
7
11
8
9
Notes:
SSS and SSA arm attachment is slightly
different from RTA. Arm modifications
located on pole to accept arms. Arms
shipped as separate item.
VD - Vibration Damper
For full-base cover on other poles, must order FBC. When ordering separately,
specify full pole nomenclature; i.e., FBC for RTA 25 7E. Also specify if pole is
existing.
Option
EPA
(sq. ft.)
Festoon Duplex Outlet, Less Electric
Festoon GFI Outlet, Less Electric
It has been found that steady 10-20 mph winds
sometimes induce second or higher mode of vibration
in lighting poles. Second mode vibration is
characterized by the maximum periodic motion
occurring at approximately the mid-height of the pole.
This type of vibration can result in failure of the pole
and/or luminaire. There is no method of predicting
destructive light pole vibration. Vibration dampers
which alleviate this condition are available. Shipped
installed.
Handhole Opening
Field Installed
Vibration Dampener
Foundation
Notes:
RTA
FVD - Field installable vibrator damper available upon
request. Consult factory.
Handheld Cover Plates
SSS HHC: For all SSS poles
All other poles order as handhole cover for full pole
description. Also specify if pole is existing.
Nut Covers
Four nut covers are standard for RSA and RTA poles
only.
Tenon Dimensions
SSS HHC: For all SSS poles
All other poles order as handhole cover for full pole description. Also specify if
pole is existing.
Tenon Mounting Slipfitters
Bolt-on Tenon Square Steel Poles
(Order separately)
Number of fixtures
Tenon O.D.
One
Two@180°
2-3/8"
2-7/8"
4"
T20-190
T25-190
T35-190
T20-280
T25-280
T35-280
Two@90° Three@120° Three@90° Four@90°
T20-290
T25-290
T35-290
T20-320
T25-320
T35-320
T20-390
T25-390
T35-390
T20-490
T25-490
T35-490
Threaded couplings and/or nipples can be factory installed. When ordering,
specify location in height and feet above base of pole and orientation from the
handhole.
CPL12
CPL34
CPL1
1/2"
3/4"
1"
threaded coupling
threaded coupling
threaded coupling
Threaded
Coupling
228
Product Guide
NPL12
NPL34
NPL1
1/2"
3/4"
1"
threaded nipple
threaded nipple
threaded nipple"
Cat. No.
A
B
C
D
Wt. (lbs.)
SBT-4S1
SBT-5S1
SBT-6S2
2-3/8"
2-3/8"
2-3/8"
3"
4"
5"
13-3/4"
13-3/4"
13-3/4"
5"
5"
5"
7
8
17
D
Notes:
1
2
Couplings & Nipples
A
Stocked in distribution centers.
Ordered on a drop-ship basis.
Tamperproof
Tamperproof (TP): Order as TP. Tamperproof screws
provided with base cover.
Threaded
Nipple
For more information, please visit our website,
www.americanelectriclighting.com
C
Aluminum Mounting Brackets
Bullhorns and Spokes - order as separate items
P R O D U C T
Projected area is for bracket only. Bracket projected area is added to
luminaire projected area to get total effective projected area (EPA). All
brackets have a luminaire rating per tenon of 4.5 sq. ft. projected area and 100
lbs. at a wind velocity of 100 mph (luminaire drag coefficient = 1.0).
O V E R V I E W
Brackets for Aluminum Poles Only
RBA32
RBA28
Finish
Natural aluminum. Optional painted finishes available. Plastic cap supplied.
Round Pole
RBA48
Brackets mount to tenon. Standard is O.D. 2-7/8" - I.D. 2-15/32". Requires T20
tenon (min. 5" tall). Heavy-duty also available for O.D. 4-1/2" - I.D. 4". Requires
T35 tenon (min. 6" tall) aluminum poles only.
Catalog
Number
EPA
(sq. ft.)
Weight
(lbs.)
Catalog
Number
EPA
(sq. ft.)
Weight
(lbs.)
RBA28
RBA32
RBA38
RBA48
RBA49
1.2
1.7
1.9
2.7
2.2
7.0
14.3
10.5
14.5
17.5
RBA28 HD
RBA32 HD
RBA38 HD
RBA48 HD
RBA49 HD
1.3
1.7
2.0
2.8
2.2
8.4
12.7
11.9
16.2
15.8
Square Pole
RBA49
RBA38
Brackets for Aluminum Poles Only
Brackets flush mount on 4", 5" and 6" square poles. For use with internal
sleeve, plain open-top poles, American Electric Lighting poles only. Must be
ordered with pole to ensure proper fit.
Catalog
Number
EPA
(sq. ft.)
Weight
(lbs.)
SBA28
SBA38
SBA48
SBA49
0.90
1.50
2.25
1.7
12
17
22
22
SBA48
SBA38
SBA49
SBA28
Product Guide
229
Steel Mounting Brackets
Bullhorns and Spokes - order as separate items
P R O D U C T
O V E R V I E W
Projected area is for bracket only. Bracket projected area is added to
luminaire projected area to get total effective projected area (EPA).
All brackets have a luminaire rating per tenon of 4.5 sq. ft. projected
area and 100 lbs. at a wind velocity of 100 mph (luminaire drag
coefficient = 1.0).
Brackets for Steel Poles Only
BS28
Finish
Dark bronze, standard. Other colors available (consult local American Electric
Lighting representative). Plastic cap supplied.
Standard Hub
Catalog
Number
EPA
(sq. ft.)
Weight
(lbs.)
BS28
BS32
BS38
BS48
BS49
1.0
1.3
1.6
2.3
1.6
21.0
34.0
32.0
44.0
44.0
O.D. 2 -7/8” - I.D. 2-1/2”
Requires T20 Tenon (min. 5” tall)
Heavy-Duty Hub
O.D. 4 1/2” - I.D. 4”
Requires T35 Tenon (min. 6” tall)
BS35
BS38
230
Catalog
Number
EPA
(sq. ft.)
Weight
(lbs.)
BS28 HD
BS32 HD
BS38 HD
BS48 HD
BS49 HD
1.3
2.0
2.2
3.4
2.8
28.0
38.0
38.0
47.0
46.0
BS48
BS49
Finish
Brackets for Square Steel Poles Only
Dark bronze, standard.
Requires T20 (2-3/8" max OD) tenon on pole for mounting
Catalog
Number
EPA
(sq. ft.)
Weight
(lbs.)
SBS 28
SBS 38
SBS 49
1.1
1.7
2.1
30.0
42.0
45.0
Product Guide
SBS28
SBS38
For more information, please visit our website,
www.americanelectriclighting.com
SBS49
RTF
Anchor Base Poles
Round Tapered Fiberglass
P R O D U C T
O V E R V I E W
Intended Use
For post-top mounting, 20’ to 45’ mounting height.
Handhole – An oval, non-metallic, 2-1/2"x5" handhole secured with a
vandal resistant, stainless steel 1/4" socket head screw.
Features
Hardware – Fasteners are high-strength galvanized zinc-plated or
stainless steel.
Shaft – Constructed by the filament winding process from
thermosetting polyester resin and contains a minimum of 65 percent
"E" type fiberglass by weight. The filament windings continuously are
applied with uniform tension and are placed on the pole helically at
low angles to provide axial strength. Additional windings are placed
on the pole in a circular manner to provide compressive strength.
Top Cap – Weatherproof, high-strength, plastic cap provided with all
drill-mount poles.
Finish – The pole is ultraviolet-resistant and pigmented approximately
the same color as the final polyurethane coating. Dark bronze (DDB)
is standard.
Anchor Base – Heavy-duty, A356-T6 aluminum base casting is
permanently bonded to the outside of the fiberglass shaft.
Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of B|," or 1"
diameter steel rod having a minimum-yield strength of 55,000 psi.
Ordering Information:
See page 217 (Note: Poles are available only in U.S.)
Technical Information
EPA (ft2) with 1.3 gust
Catalog
Number
INSTALLATION NOTES:
Installation requires grout to be packed under base to
ensure full contact with foundation. Factory-supplied
templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for
incorrect anchorage placement due to failure to use
American Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping must
be removed immediately to prevent finish damage.
RTF 20 7-3X
RTF 25 7-3X
RTF 30 8-4X
RTF 30 8-5X
RTF 30 10-5X
RTF 35 8-4X
RTF 35 8-5X
RTF 35 11-2X
RTF 40 11-7X
RTF 40 11-8X
RTF 40 12X
RTF 45 11-7X
RTF 45 11-9X
Nom.
Pole
Mount. Shaft Size
Ht. (ft.) (in. x in. x ft.)
20
25
30
30
30
35
35
35
40
40
40
45
45
7.3 x 4.6 x 20
7.3 x 4.6 x 25
8.4 x 4.6 x 30
8.5 x 4.8 x 30
10.5 x 6.6 x 30
8.4 x 4.6 x 35
8.5 x 4.8 x 35
11.2 x 6.6 x 35
11.7 x 6.2 x 40
11.8 x 6.4 x 40
12.0 x 6.9 x 40
11.7 x 6.2 x 45
11.9 x 6.6 x 45
80
mph
90
mph
100
mph
Max.
Wt.
Bolt
Circle
(in.)
Bolt
Approx.
Size
Ship Wt.
(in. x in. x in.) (lbs.)
14.4
9.6
11.2
15.6
28.7
5.5
8.5
21.8
6.4
12.2
25.8
3.9
15.2
11.1
7.3
8.5
12.0
22.4
3.8
6.2
16.6
4.3
8.8
19.3
2.0
10.9
8.9
5.7
6.7
9.5
17.4
2.7
4.7
12.5
2.4
6.0
14.3
0.6
7.6
200
200
100
200
300
100
200
300
165
300
300
300
300
11-1/2
11-1/2
11-1/2
11-1/2
14-1/2
11-1/2
11-1/2
15
15-1/2
15-1/2
15-1/2
15-1/2
15-1/2
1 x 30 x 4
1 x 30 x 4
1 x 30 x 4
1 x 30 x 4
1 x 30 x 4
1 x 30 x 4
1 x 30 x 4
1-1/4 x 36 x 6
1-1/4 x 36 x 6
1-1/4 x 36 x 6
1-1/4 x 36 x 6
1-1/4 x 36 x 6
1-1/4 x 36 x 6
62
75
106
140
202
125
161
248
165
227
317
183
295
Pole Data
A
18”
B
C
Shaft
Base
Size
Bolt
Circle
A
Bolt
Projection
B
Base
Square
C
Anchor
Bolt
Description
Template
Number
7.3"
8.4"
8.5"
10.5"
11.2
11.7"
11.8"
11.9"
12.0"
11.5"
11.5"
11.5"
14.5"
15"
15.5"
15.5"
15.5"
15.5"
4"
4"
4"
4"
4"
4"
4"
4"
4"
11"
11"
11"
13.3"
13.5"
14"
14"
14"
14"
ABRTF-7-3
ABRTF-8-4
ABRTF-8-5
ABRTF-10-5
ABRTF-11-2
ABRTF-11-7
ABRTF-11-8
ABRTF-11-9
ABRTF-12-0
PJ50114
PJ50115
PJ50116
PJ50117
PJ50118
PJ50119
PJ50120
PJ50121
PJ50122
Product Guide
231
RTFDB
Direct Buried Poles
Round Tapered Fiberglass
P R O D U C T
O V E R V I E W
Intended Use
Handhole – An oval, non-metallic, 2-1/2"x5" handhole secured with a
vandal-resistant, stainless steel 1/4" socket head screw.
For direct burial, 14’ to 35’ mounting height.
Hardware – Fasteners are high-strength galvanized zinc-plated or
stainless steel.
Features
Shaft – Constructed by the filament winding process from
thermosetting polyester resin and contains a minimum of 65 percent
"E" type fiberglass by weight. The filament windings are continuously
applied with uniform tension and are placed on the pole helically at
low angles to provide axial strength. Additional windings are placed
on the pole in a circular manner to provide compressive strength.
Top Cap – Weatherproof, high-strength, plastic cap provided with all
drill-mount poles.
Finish – Ultraviolet-resistant and pigmented approximately the same
color as the final polyurethane coating. Dark bronze (DDB) is
standard.
Ordering Information: See page 217 (Note: Poles are available only in U.S.)
INSTALLATION NOTES:
Technical Information
Do not erect poles without having fixtures
installed.
EPA (ft2) with 1.3 gust
Catalog
Number
RTFDB 18 6X
RTFDB 20 6-6X
RTFDB 24 6-7X
RTFDB 30 8-3X
RTFDB 30 8-4X
RTFDB 35 8-4X
RTFDB 35 8-5X
RTFDB 41 11-8X
Nom.
Pole
Mount. Shaft Size
80
90
Ht. (ft.) (in. x in. x ft.) mph mph
14
16
20
25
25
30
30
35
6.0 x 4.1 x 18
6.6 x 4.1 x 20
6.7 x 4.1 x 24
8.3 x 4.4 x 30
8.4 x 4.6 x 30
8.4 x 4.6 x 35
8.5 x 4.9 x 35
11.8 x 6.4 x 41
14.0
10.0
8.2
6.2
14.5
10.5
14.8
14.3
10.4
7.4
5.8
4.7
11.2
8.0
11.4
10.8
100
mph
7.9
5.5
4.1
3.6
8.9
6.2
9.0
7.8
Approx.
Max. Ship Wt.
Wt. (lbs.)
150
100
150
100
200
200
300
300
If poles are stored outside, all protective
wrapping must be removed immediately to
prevent finish damage.
34
38
46
71
98
116
153
218
Handhole
18”
Finish Grade
2’
Wiring Access
232
Product Guide
For more information, please visit our website,
www.americanelectriclighting.com
SSF
Anchor Base Poles
Square Straight Fiberglass
P R O D U C T
O V E R V I E W
Intended Use
For 6’ to 30’ mounting height.
Features
Hardware – Fasteners are high-strength, galvanized zinc-plated or
stainless steel.
Shaft – Constructed by the pultrusion process from thermosetting
polyester resin and contains a minimum of 65 percent "E" type
fiberglass by weight. The fiberglass strands traverse the length of the
pole.
Top Cap – Weatherproof, high-strength plastic cap provided with all
drill-mount poles.
Anchor Base – Heavy-duty, A356-T6 aluminum base casting
permanently is bonded to the outside of the fiberglass shaft.
Finish – Ultraviolet-resistant and pigmented approximately the same
color as the final polyurethane coating. Dark bronze (DDB) is
standard.
Base Cover – Full base cover finished to match pole.
Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of B|," or 1"
diameter steel rod having a minimum-yield strength of 55,000 psi.
Handhole – An oval, non-metallic, 2-1/2" x 5" handhole secured with a
vandal-resistant, stainless steel 1/4" socket head screw.
INSTALLATION NOTES:
Installation requires grout to be packed under base to
ensure full contact with foundation. Factory-supplied
templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for
incorrect anchorage placement due to failure to use
American Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping must
be removed immediately to prevent finish damage.
SSF 4” Shaft
A
13/16” dia. hole (4)
Ordering Information: See page 217
(Note: Poles are available only in U.S.)
Technical Information
EPA (ft2) with 1.3 gust
Catalog
Number
SSF 6 4X
SSF 8 4X
SSF 10 4X
SSF 12 4X
SSF 14 4X
SSF 16 4X
SSF 20 4X
SSF 20 5X
SSF 25 4X
SSF 25 5X
SSF 30 5X
SSF 30 5XHD
Nom.
Pole
Mount. Shaft Size
80
Ht. (ft.) (in. x in. x ft.) mph
6
8
10
12
14
16
20
20
25
25
30
30
4x4x6
4x4x8
4 x 4 x 10
4 x 4 x 12
4 x 4 x 14
4 x 4 x 16
4 x 4 x 20
5 x 5 x 20
4 x 4 x 25
5 x 5 x 25
5 x 5 x 30
5 x 5 x 30
23.2
16.5
12.0
9.1
6.7
3.7
7.2
12.2
4.2
8.7
4.7
8.6
90
mph
100
mph
Max.
wt.
17.9
12.6
8.9
6.5
4.4
2.2
1.8
9.1
2.5
6.2
2.8
5.1
14.2
9.8
6.7
4.6
2.8
1.1
0.5
6.9
0.75
4.4
1.9
2.6
150
150
150
100
100
100
150
200
150
200
200
200
8
8
8
8
8
8
8
11
8
11
11
10-12
5/8 x 21 x 3
5/8 x 21 x 3
5/8 x 21 x 3
5/8 x 21 x 3
5/8 x 21 x 3
5/8 x 21 x 3
5/8 x 21 x 3
1 x 30 x 4
5/8 x 21 x 3
1 x 30 x 4
1 x 30 x 4
1 x 30 x 4
18
23
27
31
35
39
80
110
90
115
120
164
Pole Data
C
SSF 5” Shaft
1-1/4” x 2”
slot” (4)
A
Bolt
Bolt
Approx.
Circle
Size
Ship Wt.
(in.) (in. x in. x in.) (lbs.)
Shaft
Base
Size
Bolt
Circle
A
Bolt
Projection
B
Base
Square
C
Anchor
Bolt
Description
Template
Number
4"
5"
8"
11"
3"
4"
7.4"
11.1"
ABSSF-4
ABSSF-5
PJ50123
PJ50124
Notes:
1
2
3
4
Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS)
Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180°
Options: See page 256-257
Brackets: See page 228-229
C
Product Guide
233
RTCD
Anchor Base Poles
Round Tapered Concrete
P R O D U C T
O V E R V I E W
Intended Use
For 4-1/2” O.D., 8’ to 25’ mounting height.
Features:
Construction – Centrifugal, pre-stressed concrete with a minimum
28-day compressive strength of 7000 PSI and conform with ASTMC150. Pre-stressing wire reinforcement shall conform to ASTM A-421
and the spiral wire shall conform to ASTM A-82. The spiral
reinforcement shall not be less than 13-gauge. The reinforcement
continues from the top of the pole over the entire length. The
concrete coverage over the reinforcement spiral is 1/2" thick. The
raceway opening is 2 inches minimum for wiring. Nominal handhole
size of 2.25" x 7". Ground wire runs from top of pole to handhole.
Finish – Concrete shall be color throughout with an acrylic coating.
Anchor Bolts – Top portion of anchor bolt is galvanized per ASTM
A-153. Made of steel rod having a minimum yield strength of 55,000
psi.
Ordering Information: See page 217
(Note: Poles are available only in U.S.)
INSTALLATION NOTES:
Installation requires grout to be packed under base
to ensure full contact with foundation. Factorysupplied templates must be used when setting
anchor bolts. American Electric Lighting will not
accept claim for incorrect anchorage placement due
to failure to use American Electric Lighting factory
templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping
must be removed immediately to prevent finish
damage.
Technical Information
EPA (ft2) with 1.3 gust
Pole
Catalog
Base
Height
Anchor
"A"
Base O.D.
Bolt
Circle
(sq.)
(ft. lbs.)
(lbs.)
80
90
100
19'-8"
8-1/4"
1" x 36" x 4"
11-1/2"
11"
20,100
600
12.0
11.0
10.0
RTCD 25 8-06X
24'-7"
8-1/16"
1" x 36" x 4"
11-1/2"
11"
19,910
750
12.0
9.0
6.5
RTCD 30 8-62X
29'-6"
8-5/8"
1" x 36" x 4"
11-1/2"
11"
22,540
920
10.0
7.0
5.0
RTCD 35 9-31X
34'-9"
9-5/16"
1" x 36" x 4"
14"
13"
37,500
1,200
12.0
10.0
8.0
RTCD 43 11-31X
42'-8"
11-15/16"
1" x 36" x 4"
16-1/2"
16"
51,050
2,100
12.0
8.0
5.0
B
Product Guide
Ultimate
GL Moment Weight
Number
A
Hand hole
234
Plate
RTCD 20 8-25X
C
D
Bolt
For more information, please visit our website,
www.americanelectriclighting.com
RTCDDB
Anchor Base Poles
Round Tapered Concrete
P R O D U C T
O V E R V I E W
Intended Use
For 4-1/2” O.D., 8’ to 25’ mounting height.
Features:
Construction – Centrifugal, pre-stressed concrete with a minimum 28-day
compressive strength of 7000 PSI and conform with ASTM-C150. Prestressing wire reinforcement shall conform to ASTM A-421 and the spiral
wire shall conform to ASTM A-82. The spiral reinforcement shall not be less
than 13-gauge. The reinforcement continues from the top of the pole over
the entire length. The concrete coverage over the reinforcement spiral is
1/2" thick. The raceway opening is 2 inches minimum for wiring. Nominal
handhole size of 2.25" x 7". Ground wire runs from top of pole to handhole.
Finish – Concrete shall be color throughout with an acrylic coating.
Ordering Information: See page 217
(Note: Poles are available only in U.S.)
Technical Information
EPA(ft2) with 1.3 gust
Pole
Catalog
Ultimate
Height
Embedded
Overall
GL Moment Weight
Number
"A"
Base O.D.
Depth
Length
(ft. lbs.)
(lbs.)
80
90
100
RTCDDB 20 8-00X
19'-8"
8"
4' - 11'
24'-7"
17,440
750
13.0
11.0
10.0
RTCDDB 25 8-56X
24'-7"
89/16"
4' - 11'
29'-6"
19,910
850
12.0
9.0
6.5
RTCDDB 30 9-25X
29'-6"
91/4"
5' - 3'
34'-9"
22,540
1,200
10.0
7.0
5.0
RTCDDB 35 11-93X
36'-0"
1115/16"
6' - 8'
42'-8"
42,200
2,100
12.0
10.0
8.0
RTCDDB 43 13-33X
42'-8"
13"
6' - 5'
49'-2"
49,300
2,850
12.0
8.0
5.0
INSTALLATION NOTES:
Installation requires grout to be packed under
base to ensure full contact with foundation.
Factory-supplied templates must be used when
setting anchor bolts. American Electric Lighting
will not accept claim for incorrect anchorage
placement due to failure to use American
Electric Lighting factory templates.
Do not erect poles without having fixtures
installed.
If poles are stored outside, all protective
wrapping must be removed immediately to
prevent finish damage.
Ground Line
Product Guide
235
STC
Anchor Base Poles
Square Tapered Concrete
P R O D U C T
O V E R V I E W
Intended Use
Handhole – A 3"x5" handhole is located 24" above ground line and a 21/2" x 7" minimum conduit entrance is located 18" below ground line.
Inserts for the handhole and conduit entrance are non-corrosive and
weatherproof. Handhole frames and covers conform to ASTM-B240.
For direct burial, 16’ to 38’ mounting height.
Features
Shaft – Concrete mix has a minimum 28-day compressive strength of
6,500 PSI and conforms with ASTM-C150. Prestressing steel
reinforcement is uncoated 7 wire, stress relieved strand per ASTMA416. Steel spiral reinforcement conforms to ASTM-A82 and is not
less than .120 (11-gauge) diameter. Poles have a continuous taper of
0.165 inches per foot.
Grounding – An 18" long, #4 stranded copper pigtail, connected to
reinforced strand, is provided at pole top and at cable entrance below
grade.
Hardware – Fasteners are high-strength galvanized zinc-plated or
stainless steel.
Top Cap – Weatherproof top cap provided with all drill-mount poles.
Finish – Smooth, natural form finish, soft gray color is standard.
Ordering Information: See page 217 (Note: Poles are available only in U.S.)
INSTALLATION NOTES:
Technical Information
Do not erect poles without having fixtures installed.
EPA (ft ) with 1.3 gust
2
Catalog
Number
STC 20 7-24X
STC 20 9-24X
STC 25 8-05X
STC 25 10-05X
STC 30 8-86X
STC 30 10-86X
STC 35 9-67X
STC 35 11-67X
STC 40 12-48X
STC 45 13-29X
Nom.
Mount.
Ht. (ft.)
Pole
Shaft Size
(in. x in. x ft.)
80
mph
Max
wt.
90
mph
Max
Wt.
100
mph
Max.
Wt.
Approx.
Ship Wt.
(lbs.)
16
16
20
20
25
25
29
29
34
38
4.0 x 7.24 x 20
6.0 x 9.24 x 20
4.0 x 8.05 x 25
6.0 x 10.05 x 25
4.0 x 8.86 x 30
6.0 x 10.86 x 30
4.0 x 9.67 x 35
6.0 x 11.67 x 35
6.0 x 12.48 x 40
6.0 x 13.29 x 45
22
48
21
44
20
49
17
43
42
41
550
1,220
510
1,050
460
1,090
400
1,010
920
820
16
37
16
34
15
33
12
32
30
31
430
950
390
810
340
830
290
760
670
590
13
29
12
26
11
28
8
24
22
22
330
760
300
640
250
650
200
580
500
420
680
1,110
985
1,530
1,350
2,000
1,800
2,540
3,130
3,795
If poles are stored outside, all protective wrapping must be
removed immediately to prevent finish damage.
3’ x 5’ Handhole
with Cover
24”
18”
Cast in 1-1/2”
Hole @ 45o
Finish Grade
236
Product Guide
For more information, please visit our website,
www.americanelectriclighting.com
SPRTC
Direct Burial Poles
Round Tapered Concrete Sportslighting
P R O D U C T
O V E R V I E W
Intended Use
For 6’ to 30’ mounting height.
Features
Shaft – Concrete mix has a minimum 28-day compressive strength of
11,000 PSI and conforms with ASTM-C150. Prestressing steel
reinforcement is uncoated 7 wire, stress relieved strand per ASTMA416. Steel spiral reinforcement conforms to ASTM-A82 and is not
less than .203 (5-gauge wire) diameter. Poles have a continuous taper
of 0.216 inches per foot. Poles are centrifugally spun and round in
cross-section with a hollow center.
Handhole – 4"x8" handhole is located 24" above ground line. 4"x8"
conduit entrance is located 18" below ground line. 2-1/2"x8" reinforced
handhole with flush cover is located at cage/crossarm locations.
1-1/2" coupling wire inlet/outlet is located opposite this handhole.
Inserts for handhole and conduit entrance are non-corrosive and
weatherproof. Handhole frames and covers conform to ASTM-B240.
Grounding – A continuous solid or stranded copper ground wire is
cast into the pole. Wire terminates at top of pole to accept a 1/2"x24"
lightning rod and approximately 12" below grade. Copper coupling
provides a 1/2" tapped insert at pole face for grounding hardware.
Hardware – Fasteners are high-strength galvanized zinc-plated or
stainless steel.
Finish – Smooth, natural form finish, soft gray color is standard.
Ordering Information: See page 217 (Note: Poles are
available only in U.S.)
Technical Information
EPA (ft2) with 1.3 gust
INSTALLATION NOTES:
Do not erect poles without having fixtures
installed.
If poles are stored outside, all protective
wrapping must be removed immediately to
prevent finish damage.
24”
Catalog
Number
SPRTC C6 45 7-17
SPRTC C5 45 7-17
SPRTC C4 45 7-17
SPRTC C4 60 7-20
SPRTC C2 60 9-22
SPRTC H1 60 9-22
SPRTC C3 70 9-24
SPRTC C1 70 9-24
SPRTC H2 70 10-24
SPRTC C2 80 9-26
SPRTC C1 80 9-26
SPRTC H2 80 10-26
SPRTC C2 90 9-28
SPRTC C1 90 9-28
SPRTC H2 90 10-28
SPRTC C1 105 9-32
SPRTC H1 105 9-32
SPRTC H3 105 11-34
SPRTC C1 115 9-34
SPRTC H1 115 9-34
SPRTC H2 115 10-34
Nom.
Mount.
Ht. (ft.)
Pole
Shaft Size
(in. x in. x ft.)
80
mph
Max
Wt.
90
mph
Max
Wt.
100
mph
38
38
38
50
50
50
60
60
60
68
68
68
77
77
77
91
91
91
100
100
100
6.75 X 16.47 X 45
6.75 X 16.47 X 45
6.75 X 16.47 X 45
6.75 X 19.71 X 60
8.82 X 21.78 X 60
8.82 X 21.78 X 60
8.82 X 23.94 X 70
8.82 X 23.94 X 70
8.82 X 23.94 X 70
8.82 X 26.1 X 80
8.82 X 26.1 X 80
8.82 X 26.1 X 80
8.82 X 28.26 X 90
8.82 X 28.26 X 90
8.82 X 28.26 X 90
8.82 X 31.5 X 105
8.82 X 31.5 X 105
11.0 X 33.68 X 105
8.82 X 33.66 X 115
8.82 X 33.66 X 115
8.82 X 33.66 X 115
31
39
52
47
85
138
56
90
139
63
85
136
54
78
132
70
99
144
65
96
125
620
780
1,040
893
1,615
2,622
1,064
1,710
2,641
1,197
1,445
2,584
1,026
1,482
2,508
1,330
1,881
2,736
1,235
1,824
2,375
24
30
40
35
65
101
42
69
103
45
65
101
39
56
97
49
74
105
45
70
91
480
600
800
665
1,235
1,919
798
1,311
1,957
855
1,105
1,919
741
1,064
1,843
931
1,406
1,995
855
1,330
1,729
18
23
31
26
48
80
32
52
81
34
48
79
28
42
75
35
54
80
31
50
69
Approx.
Max. Ship Wt.
Wt.
(lbs.)
360
460
589
520
912
1,520
608
988
1,539
646
816
1,501
532
798
1,425
665
1,026
1,520
589
950
1,311
3,400
3,400
3,450
5,450
7,950
8,100
9,900
10,100
10,400
12,300
12,300
12,800
14,850
14,950
15,350
19,250
19,450
22,050
22,350
22,550
22,800
Cast in 4” x 8”
Handhole Frame and Cover
1/2” Ground Coupling
18”
Cast in 4” x 8” Slot
Product Guide
237
SPRTC
Crossarm Options
For Round Tapered Concrete Sportslighting Poles
P R O D U C T
O V E R V I E W
Angle Iron Crossarms for Concrete Poles
Projected area is for the crossarm only. The crossarm projected area
is added to the luminaire projected area to get a total effective
projected area (EPA).
ACRCW6
6-Fixture Angle Arm
Pole and Mounting Hardware:
see note
2”-6”
3.5” x 5.0” x 0.25” angle
6.0”
13’-6”
6’-9”
6.50”
ACRCW5
5-Fixture Angle Arm
Pole and Mounting Hardware:
see note
Angle Iron Crossarms
For Concrete Poles
2”-6”
3.5” x 5.0” x 0.25” angle
6.0”
11’ 0”
4’ 3”
6.50”
Notes:
1
238
Connecting hardware for crossarm to pole is supplied
by others. Bolt holes in c-channel are 0.88” diameter.
Product Guide
For more information, please visit our website,
www.americanelectriclighting.com
Catalog
Number
Arm EPA
(sq. ft.)
Weight
(lbs.)
ACRCW2
ACRCW3
ACRCW4
ACRCW5
ACRCW6
1.80
3.00
4.50
5.70
7.00
50.0
86.0
121.0
157.0
193.0
SPRTC
Crossarm Options
For Round Tapered Concrete Sportslighting Poles
P R O D U C T
O V E R V I E W
Angle Iron Crossarms for Concrete Poles
Projected area is for the crossarm only. The crossarm projected area
is added to the luminaire projected area to get a total effective
projected area (EPA).
ACRCW4
4-Fixture Angle Arm
Pole and Mounting Hardware:
see note
2’ 6”
3.5” x 5.0” x 0.25” angle
6.0”
8’ 6”
4’ 3”
6.50”
ACRCW3
3-Fixture Angle Arm
Pole and Mounting Hardware:
see note
3.5” x 5.0” x 0.25” angle
6.0'
2’ 6”'
1’ 9”
6.0'
6.50”
ACRCW2
2-Fixture Angle Arm
Pole and Mounting Hardware:
see note
3.5” x 5.0” x 0.25”
angle
6.0'
3’ 6”
1’ 9”
6.50”
Notes:
1
Connecting hardware for crossarm to pole is supplied
by others. Bolt holes in c-channel are 0.88” diameter.
Product Guide
239
SPRTC
Crossarm Options
For Round Tapered Concrete Sportslighting Poles
P R O D U C T
O V E R V I E W
Pre-wired Tubular Crossarms for Concrete Poles
Pre-wired Tubular
Crossarms
For Concrete Poles
Projected area is for the crossarm only. The crossarm projected area
is added to the luminaire projected area to get a total effective
projected area (EPA).
SPXCW6
Pole and Mounting Hardware:
see note
6-Fixture Crossarm
Catalog
Number
EPA
(sq. ft.)
Weight
(lbs.)
SPXCW2
SPXCW3
SPXCW4
SPXCW5
SPXCW6
1.00
1.80
2.50
3.20
3.90
23.5
40.0
56.5
73.0
89.5
2’ 6”
Gusset
(4 places)
2.5” Sched. 40 pipe
(2.88” O.D.)
13’ 6”
6.0”
6’ 9”
6.50”
SPXCW5
5-Fixture Crossarm
Pole and Mounting Hardware:
see note
Gusset
(4 places)
2.5” Sched. 40 pipe (2.88” O.D.)
6.0”
2’ 6”
11’ 0”
6.50”
SPXCW4
4-Fixture Crossarm
2.5” Sched. 40 pipe
(2.88” O.D.)
4’ 3”
SPXCW2
2-Fixture Crossarm
Pole and Mounting Hardware:
see note
Gusset
(4 places)
Pole and Mounting Hardware:
see note
6.0”
2’ 6”
2.5” Sched. 40 pipe
(2.88” O.D.)
8’ 6”
Gusset
(4 places)
6.0”
4’ 3”
6.50”
3’ 6”
1’ 9”
6.50”
SPXCW3
3-Fixture Crossarm
Pole and Mounting Hardware:
see note
Gusset
(4 places)
2’ 6”
6.0”
Notes:
6’ 0”
240
Product Guide
1’ 9”
6.50”
For more information, please visit our website,
www.americanelectriclighting.com
1
Connecting hardware for crossarm to pole is supplied
by others. Bolt holes in c-channel are 0.88” diameter.
SPRTS
Anchored Base Poles
Round Tapered Steel
P R O D U C T
Intended Use
O V E R V I E W
For 40’ to 80’ mounting height.
Handhole – An oval, reinforced handhole rim having a nominal
dimension of 4"x6.5". Steel cover with attachment screws included.
Handhole is located 18" above base.
Features
Grounding – Nut holder located immediately inside handhole rim is
provided with 1/2" – 13 UNC ground bolt and nut.
Shaft – The cross section shall be round or 16-sided with a 4" bend
radius. Each pole is a constant tapered hollow steel section and shall
be up to 55 feet in length with a minimum 1-1/2 times diameter slip
joint as standard. The pole shaft sections shall be high strength low
alloy steel conforming to ASTM A572 Grade 65 or ASTM A595 Grade
A. The plate shall be single thickness – no laminations.
Anchor Bolts – Fabricated from commercial-quality, hot-rolled carbon
steel with minimum-yield strength of 55,000 PSI. Bolts have an "L"
bend on one end.
Hardware – Fasteners are high-strength galvanized zinc-plated or
stainless steel.
Top Cap – Weather-proof removable top cap provided with all drillmount poles.
Anchor Base – Fabricated from hot-rolled carbon steel plate that
conforms to ASTM A36 or ASTM A572 Grade 42.
Ordering Information: See page 217 (Note: Poles are available only in U.S.)
Technical Information
EPA (ft2) with 1.3 gust
Catalog
Number
SPRTS 40 HT01
SPRTS 40 HT02
SPRTS 40 HT03
SPRTS 50 HT01
SPRTS 50 HT02
SPRTS 50 HT03
SPRTS 50 HT04
SPRTS 50 HT05
SPRTS 60 HT01
SPRTS 60 HT02
SPRTS 60 HT03
SPRTS 60 HT04
SPRTS 70 HT01
SPRTS 70 HT02
SPRTS 70 HT03
SPRTS 70 HT04
SPRTS 70 HT05
SPRTS 80 HT01
SPRTS 80 HT02
SPRTS 80 HT03
SPRTS 80 HT04
Nom. Base
mount. Dia.
ht (ft.) (in.)
40
40
40
50
50
50
50
50
60
60
60
60
70
70
70
70
70
80
80
80
80
—
—
—
—
—
—
—
—
5
6.5
6.6
12
6.6
6.6
12
12
12
12
12
13
12
Wall
Thick.
(in.)
Base
Dia.
(in.)
Wall
Thick.
(in.)
80
mph
Max.
Wt.
90
mph
Max.
Wt.
100
mph
Max.
Wt.
Bolt
Bolt
Num. of
Circle
Size
Anchor
(in.) (in. x in. x in.) Bolts
—
—
—
—
—
—
—
—
0.1196
0.1196
0.1793
0.1793
0.1793
0.1793
0.1793
0.1793
0.1793
0.1793
0.1793
0.1875
0.1793
9
9
10
10
10
11
13
13
11.5
13
13
15.87
13
13
14.57
15.87
16.82
15.87
16.82
17.53
18.7
0.1193
0.1793
0.1793
0.1193
0.1793
0.1793
0.1793
0.2391
0.1793
0.1793
0.2391
0.1875
0.1793
0.2391
0.1875
0.1875
0.1875
0.1875
0.1875
0.2092
0.1875
17.2
26.1
38.6
13.2
20.5
29.9
50.4
69.2
20.0
36.0
49.0
78.0
20.6
23.8
39.0
52.0
65.0
37.0
45.0
58.0
70.0
430
654
965
330
512
748
1,260
1,730
600
1,080
1,470
2,340
515
595
1,170
1,560
1,950
1,110
1,350
1,740
2,100
13.5
20.6
30.6
10.6
16.5
23.5
39.7
55.0
16.0
29.0
40.0
62.0
16.7
19.3
30.0
41.0
53.0
29.0
36.0
46.0
56.0
338
517
765
265
412
588
992
1,375
480
870
1,200
1,860
417
482
900
1,230
1,590
870
1,080
1,380
1,680
10.8
16.7
24.6
8.3
13.6
18.6
31.4
44.2
13.0
22.0
32.0
50.0
13.7
15.9
23.0
33.0
42.0
23.0
28.0
35.0
44.0
270
419
615
208
340
465
785
1,105
390
660
960
1,500
342
397
690
990
1,260
690
840
1,050
1,320
12.5
12.5
13.5
13.5
13.5
15
17
17.5
16
17
17
21
17
17.5
19
21
22.75
21
22.75
23
23
1 x 36 x 4
1.25 x 42 x 6
1.25 x 42 x 6
1 x 36 x 4
1.25 x 42 x 6
1.25 x 42 x 6
1.50 x 54 x 6
1.75 x 84 x 6
1.25 x 42 x 6
1.25 x 42 x 6
1.50 x 54 x 6
1.50 x 54 x 6
1.50 x 54 x 6
1.75 x 84 x 6
1.25 x 42 x 6
1.50 x 54 x 6
1.50 x 54 x 6
1.50 x 54 x 6
1.50 x 54 x 6
1.50 x 54 x 6
1.50 x 54 x 6
4
4
4
4
4
4
4
4
4
6
6
6
4
4
6
6
6
6
6
6
8
INSTALLATION NOTES:
Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied
templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use
American Electric Lighting factory templates.
Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage.
4-Bolt
6-Bolt
8-Bolt
Handhole
Handhole
Handhole
Product Guide
241
SPRTS
Crossarm Options
For Round Tapered Steel Sportslighting Poles
P R O D U C T
O V E R V I E W
Angle Iron Crossarms for Steel Poles
Pre-wired Tubular
Crossarms
For Concrete Poles
Projected area is for the crossarm only. The crossarm projected area
is added to the luminaire projected area to get a total effective
projected area (EPA).
ACR6
6-Fixture Angle Arm
13’ 0”
Catalog
Number
Arm EPA
(sq. ft.)
Weight
(lbs.)
ACR2
ACR3
ACR4
ACR5
ACR6
1.98
3.12
4.53
5.95
7.37
34.0
54.0
78.0
103.0
127.0
2’ 6”
1.75”
8”
6’ 2”
1.75”
ACR5
ACR4
5-Fixture Angle Arm
4-Fixture Angle Arm
8’ 0”
10’ 6”
2’ 6”
1.75”
2’ 6”
3’ 8”
4’ 11”
8”
3’8”
8”
4’ 11”
1.75”
2.00”
ACR3
ACR2
3-Fixture Angle Arm
2-Fixture Angle Arm
5’ 6”
2’ 6”
2’ 5”
3’ 6”
3’ 0”
1.75”
1’ 5”
2’ 5”
2.00”
242
Product Guide
1.75”
For more information, please visit our website,
www.americanelectriclighting.com
1.75”
1’ 5”
SPRTS
Crossarm Options
For Round Tapered Steel Sportslighting Poles
P R O D U C T
O V E R V I E W
Tubular Crossarms for Steel Poles
Tubular Crossarms
For Steel Poles
Projected area is for the crossarm only. The crossarm projected area
is added to the luminaire projected area to get a total effective
projected area (EPA).
Catalog
Number
EPA
(sq. ft.)
Weight
(lbs.)
CR2
CR3
CR4
CR5
CR6
CR7
CR8
1.28
2.45
3.21
4.17
5.13
6.10
7.06
44.0
65.0
98.0
116.0
150.0
176.0
271.0
CR8
8-Fixture Crossarm
22’ 0”
3’ 0”
3” Shed 40 pipe
CR7
CR6
7-Fixture Crossarm
6-Fixture Crossarm
16’ 0”
19’ 0”
3’ 0”
3” Shed
40 pipe
3’ 0”
3” Shed
40 pipe
CR5
CR4
5-Fixture Crossarm
4-Fixture Crossarm
13’ 0”
10’ 0”
13’ 0”
3’ 0”
3” Shed
40 pipe
3” Shed
40 pipe
3’ 0”
CR3
CR2
3-Fixture Crossarm
2-Fixture Crossarm
4’ 0”
7’ 0”
3” Shed
40 pipe
3” Shed
40 pipe
3’ 0”
3’ 0”
Product Guide
243
RTAU
Anchor Base Poles / Mounting Arm Combo
Round Tapered Aluminum Pole with Mounting Arm
P R O D U C T
O V E R V I E W
/
O R D E R I N G
I N F O R M AT I O N
Intended Use
20’ to 40’ fixture mounting.
Pole Grounding System — A ground lug located immediately inside
the handhole is tapped for 3/8"-16 UNC ground bolt (not supplied).
Features
Pole Installation — Anchor bolts — Top portion of anchor bolt is
galvanized per ASTM A-153. Made of steel rod having a minimum
yield strength of 55,000 psi.
Pole Construction — Spun-tapered seamless 6063 alloy aluminum
tubing, heat treated to produce a T6 temper. Circumferential satinbrushed finish. The shaft is cone-tapered to the butt diameter.
Mounting Arm Construction — Body of the mounting arm is tapered
aluminum alloy 6063-T6 tube with a 2-3/8" O.D. (2" NPS) pipe size at the
luminaire end. The pole end of the arm is welded to an aluminum alloy
6063-T6 mounting plate.
Three sections cast from A356 alloy aluminum; the anchor base is
heat treated to a T6 condition. The anchor base telescopes the pole
shaft and is circumferentially welded at both the top and the bottom.
Welding follows AWS and CSA standards. Arms are chemically
cleaned after fabrication.
A nominal 3" x 5" or 4" x 6" reinforced flush-covered handhole is
centered 18" above the base.
Mounting — The mounting plate is designed to be bolted to the shaft
using four 1/2" stainless steel bolts, nuts and washers. A grommet is
provided for the 1-1/4" diameter wiring hole between the pole shaft
and the bracket arm.
Cast aluminum cap provided.
All screws, nuts and bolts are made of stainless steel.
A356 nut covers are included with each anchor base unless
otherwise specified.
Mounting Arm Finish — Satin aluminum is standard. Optional
polyester powder paint and anodized finishes available.
Pole Finish — Brushed aluminum (BA) is standard. Optional polyester
powder paint and anodized finishes available.
Example: R T A U 2 0 6 G B M A U S 8 V D B A A E L
Ordering Information:
Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, please add AEL after the last option
RTAU
Shaft/Arm type
Fixture mounting
height
RTAU
20 - 40 feet
(See chart on
page 246)
Nominal Shaft
Base Size/
Wall Thickness
Options
Mounting
BMA
(See chart on
page 246)
Bolt-on
mast arm
Arm Length1
US4
US6
US8
Notes:
1 Some restrictions apply, chart on
page 246 for details.
2 Specify location and orientation when
ordering option.
For 1st "x": Specify the height in feet
above base of pole.
Use two digits to specify height:
Example: 5 ft = 05 and 20 ft = 20
For 2nd "x": Specify orientation from
handhole (A, B, C, D)
Refer to the Handhole Orientation
diagram on this page.
3 Horizontal arm is 18" x 2-3/8" O.D.
tenon standard.
4 Other colors available, please contact
local AEL representative.
244
Product Guide
4' arm length
6' arm length
8' arm length
C
D
Shipped Installed
L/AB Less anchor bolts
FBC Full base cover
VD Vibration damper
TP Tamper proof
HAAxx2,3 Horizontal arm
Bracket (1 fixture)
FDLxx2 Festoon outlet less
electrical
FGLxx2 Festoon GFI outlet
less electrical
12CPxx2 1/2" coupling
34CPxx2 3/4" coupling
1CPxx2 1" coupling
12NPxx2 1/2" threaded nipple
34NPxx2 3/4" threaded nipple
1NPxx2 1" threaded nipple
HHxx2 Extra handhole
B
Arm located
on side B
A
Handhole
For more information, please visit our website,
www.americanelectriclighting.com
Architectural Colors
(powder finish)4
Standard Colors
BA Brushed
aluminum (std)
DDB Dark bronze
DWH White
DBL Black
Class 1 Arch. Anodize
ABL Black
ADB Dark bronze
ANA Natural
RTAU
Anchor Base Poles / Mounting Arm Combo
Round Tapered Aluminum Pole with Twin Mounting Arms
P R O D U C T
O V E R V I E W
Intended Use
/
O R D E R I N G
I N F O R M AT I O N
20’ to 40’ fixture mounting.
Pole Grounding System — A ground lug located immediately inside
the handhole is tapped for 3/8"-16 UNC ground bolt (not supplied).
Features
Pole Installation — Anchor bolts — Top portion of anchor bolt is
galvanized per ASTM A-153. Made of steel rod having a minimum
yield strength of 55,000 psi.
Pole Construction — Spun-tapered seamless 6063 alloy aluminum
tubing, heat treated to produce a T6 temper. Circumferential satinbrushed finish. The shaft is cone-tapered to the butt diameter.
Mounting Arm Construction — Body of the mounting arm is tapered
aluminum alloy 6063-T6 tube with a 2-3/8" O.D. (2" NPS) pipe size at the
luminaire end. The pole end of the arm is welded to an aluminum alloy
6063-T6 mounting plate.Welding follows AWS and CSA standards.
Arms are chemically cleaned after fabrication.
Cast from A356 alloy aluminum, the anchor base is heat treated to a
T6 condition. The anchor base telescopes the pole shaft and is
circumferentially welded at both the top and the bottom.
Mounting — The mounting plate is designed to be bolted to the shaft
using four 1/2" stainless steel bolts, nuts and washers. A grommet is
provided for the 1-1/4" diameter wiring hole between the pole shaft
and the bracket arm.
A nominal 3" x 5" or 4" x 6" reinforced flush-covered handhole is
centered 18" above the base.
Cast aluminum cap provided.
Mounting Arm Finish — Satin aluminum is standard. Optional
polyester powder paint and anodized finishes available.
All screws, nuts and bolts are made of stainless steel.
A356 nut covers are included with each anchor base unless
otherwise specified.
Pole Finish — Brushed aluminum (BA) is standard. Optional polyester
powder paint and anodized finishes available.
Example: R T A U 2 0 6 G B M A 2 U S 4 B A V D A E L
Ordering Information:
Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option.
RTAU
Shaft/Arm Type
Fixture Mounting
Height
RTAU
20 - 40 feet
Nominal Shaft
Base Size/
Wall Thickness
Options
Mounting
BMA
Bolt-on
mast arm
(See chart on
page 246)
Arm Length1
2US4
2US6
2US8
Notes:
1 Some restrictions apply, see
chart on page 246 for details.
2 Specify location and orientation when
ordering option.
For 1st "x": Specify the height in feet
above base of pole.
Use two digits to specify height:
Example: 5 ft = 05 and 20 ft = 20
For 2nd "x": Specify orientation from
handhole (A, B, C, D)
Refer to the Handhole Orientation
diagram on this page.
3 Horizontal arm is 18" x 2-3/8" O.D.
tenon standard.
4 Other colors available, please contact
your local American Electric Lighting
representative.
4' arm length
6' arm length
8' arm length
C
D
Shipped Installed
L/AB Less anchor bolts
FBC Full base cover
VD Vibration damper
TP Tamper proof
HAAxx2,3 Horizontal arm
Bracket (1 fixture)
FDLxx2 Festoon outlet less
electrical
FGLxx2 Festoon GFI outlet
less electrical
12CPxx2 1/2" coupling
34CPxx2 3/4" coupling
1CPxx2 1" coupling
12NPxx2 1/2" threaded nipple
34NPxx2 3/4" threaded nipple
1NPxx2 1" threaded nipple
HHxx2 Extra handhole
Architectural Colors
(powder finish)3
Standard Colors
BA Brushed
Aluminum (std)
DDB Dark bronze
DWH White
DBL Black
Class 1 Arch. Anodize
ABL Black
ADB Dark bronze
ANA Natural
B Arms
located on
sides B & D
A
Handhole
Product Guide
245
RTAU
Anchor Base Poles / Mounting Arm Combo
Round Tapered Aluminum Pole with Twin Mounting Arms
P R O D U C T
O V E R V I E W
/
O R D E R I N G
I N F O R M AT I O N
Technical Information
EPA (ft2) with 1.3 gust
246
AEL Catalog Number
Fixture Mtg.
Height1
(ft.)
Mtg. Arm
length
(ft.)
Pole Shaft
Dia.
(in. x in.)
RTAU 20 6G BMA 2US4
RTAU 20 6G BMA 2US6
RTAU 20 6G BMA 2US8
RTAU 20 6E BMA 2US4
RTAU 20 6E BMA 2US6
RTAU 20 6E BMA 2US8
RTAU 25 6G BMA 2US4
RTAU 25 6E BMA 2US6
RTAU 25 7E BMA 2US6
RTAU 25 7E BMA 2US4
RTAU 25 7E BMA 2US6
RTAU 25 7E BMA 2US8
RTAU 30 8G BMA 2US4
RTAU 30 8G BMA 2US6
RTAU 30 8G BMA 2US8
RTAU 30 8E BMA 2US4
RTAU 30 8E BMA 2US6
RTAU 30 8E BMA 2US8
RTAU 30 7E BMA 2US4
RTAU 30 7E BMA 2US6
RTAU 30 7E BMA 2US8
RTAU 35 8G BMA 2US4
RTAU 35 8G BMA 2US6
RTAU 35 8J BMA 2US4
RTAU 35 8J BMA 2US6
RTAU 35 8J BMA 2US8
RTAU 35 8E BMA 2US6
RTAU 35 8E BMA 2US8
RTAU 40 8G BMA 2US8
RTAU 40 8L BMA 2US6
RTAU 40 8J BMA 2US6
RTAU 40 8J BMA 2US8
RTAU 40 8J BMA 2US4
20
20
20
20
20
20
25
25
25
25
25
25
30
30
30
30
30
30
30
30
30
35
35
35
35
35
35
35
40
40
40
40
40
4
6
8
4
6
8
4
6
6
4
6
8
4
6
8
4
6
8
4
6
8
4
6
4
6
8
6
8
8
6
6
8
4
4x6
4x6
4x6
4x6
4x6
4x6
4x6
4x7
4x7
4x7
4x7
4x7
4.5 x 8
4.5 x 8
4.5 x 8
4.5 x 8
4.5 x 8
4.5 x 8
4.5 x 7
4.5 x 7
4.5 x 7
4.5 x 8
4.5 x 8
4.5 x 8
4.5 x 8
4.5 x 8
4.5 x 8
4.5 x 8
4.5 x 8
4.5 x 8
4.5 x 8
4.5 x 8
4.5 x 8
Product Guide
Wall
Thickness
(in.)
0.188
0.188
0.188
0.156
0.156
0.156
0.188
0.156
0.188
0.156
0.156
0.156
0.188
0.188
0.188
0.156
0.156
0.156
0.156
0.156
0.156
0.188
0.188
0.250
0.250
0.250
0.156
0.156
0.188
0.219
0.250
0.250
0.250
(Max per Arm)
EPA ft2 with 1.3 Gust
80 mph
90 mph
100 mph
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1.9
0.8
1.3
1.8
2
2
1.8
0.7
2
2
2
2
1.8
0.8
2
1.8
2
1.8
1.3
2
2
2
1.3
2
2
2
1.9
0.9
2
2
1.9
0.8
1.5
0.9
n/a
0.6
0.8
1.5
1.3
0.8
n/a
2
1.9
0.9
1.3
0.8
n/a
1.3
0.8
0.9
0.8
n/a
2
2
1.1
n/a
1.1
1.3
2
0.8
n/a
1.4
For more information, please visit our website,
www.americanelectriclighting.com
Max. Weight
per Arm
(lbs.)
Bolt
Circle
(in.)
Bolt Size
(in.)
App. Ship
Weight
(lbs.)
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
9-10
9-10
9-10
9-10
9-10
9-10
9-10
9-10
10-11
10-11
10-11
10-11
11-12
11-12
11-12
11-12
11-12
11-12
10-11
10-11
10-11
11-12
11-12
11-12
11-12
11-12
11-12
11-12
11-12
11-12
11-12
11-12
11-12
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 30 x 3
3/4 x 30 x 3
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 42
1 x 36 x 42
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
107
110
112
94
97
99
117
120
135
144
147
134
183
186
188
160
163
165
156
159
161
14
17
263
266
268
190
192
241
271
301
303
298
RTAU
Anchor Base Poles / Mounting Arm Combo
Round Tapered Aluminum Pole with Twin Mounting Arms
P R O D U C T
O V E R V I E W
/
O R D E R I N G
I N F O R M AT I O N
Notes:
1. Denotes fixture mounting heights, NOT nominal pole height.
Shaft
Base
Size
Bolt
Circle
A
Bolt
Projection
B
6"
7"
8"
9"–10"
10"–11"
11"–12"
3-1/2"
4-1/8"
4-1/4"
Base
Anchor
Warehouse Template
Square
Bolt
Anchor Bolt Number
C
Description Description
10"
10-1/2"
11-1/2"
ABRTA-6
ABRTA-7
ABRTA-8
AB30-0
AB36-0
AB36-0
PJ50033
PJ50034
PJ50035
IMPORTANT:
• Do not erect poles without having fixtures installed.
• Factory-supplied templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for incorrect anchorage
placement due to failure to use factory template.
• If poles are stored outside, all protective wrapping must be removed
immediately to prevent finish damage.
• Installation requires grout be packed under base to ensure full contact with
foundation.
Peripherally
reinforced
handhole door
Cast aluminum
nut cover
Grout
18”
B
IMPORTANT:
• These specifications are intended for general purposes only. American
Electric Lighting reserves the right to change material or design without
prior notice, in a continuing effort to upgrade its products.
Product Guide
247
RTSU
Anchor Base Poles / Mounting Arm Combo
Round Tapered Steel Pole with Single Mounting Arm
P R O D U C T
O V E R V I E W
/
O R D E R I N G
Intended Use
I N F O R M AT I O N
Pole Finish — Galvanized steel (GALV) is standard. Optional polyester
powder paint finishes available.
20’ to 40’ fixture mounting.
Pole Grounding System — A ground lug is located immediately inside
the handhole rim.
Features
Pole Construction — Weldable-grade hot-rolled, commercial-quality
carbon steel tubing with a minimum yield of 55,000 psi. Uniform wall
thickness of 11-gauge (0.1196") or 7-gauge (0.1793"). Shafts are onepiece construction with a full-length longitudinal high-frequency
resistance weld. Round in cross-section having a uniform taper of
approximately .14" per foot.
Anchor base is fabricated from hot-rolled carbon steel plate that
conforms to ASTM A36.
A reinforced handhole having nominal dimensions of 3" x 5" for shafts
less than 6.25" base diameter and 4" x 6.5" for all other shafts. Cover
with attachment screws included. Handhole is located 18" above the
base.
Pole Installation — Anchor bolts — Fabricated from commercialquality, hot-rolled carbon steel with minimum yield strength of 55,000
psi. Bolts have an "L" bend on one end.
Mounting Arm Construction — Body is 2-3/8" O.D. (2" NPS) galvanized
steel tube (sch. 40 material, min. yield strength 36,000 psi).
Welding follows AWS standards. Arms are galvanized after fabrication.
Mounting Arm Hardware — Mounting plate is designed to be bolted to
the shaft using a 1/2" steel bolt Simplex mount. Single-bolt (US4, US6,
US8) or multi-bolt design (US10, US12).
Mounting Arm Finish— Galvanized steel (GALV) is standard. Optional
polyester powder paint finishes available.
Weatherproof, removable top cap provided.
Fasteners are high-strength galvanized zinc-plated or stainless steel.
Example: R T S U 2 5 S M P U S 4 G A L V V D A E L
Ordering Information:
Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option.
RTSU
Shaft/Arm type
Fixture Mounting
Height
Nominal Shaft
Base Size/
Wall Thickness
20 - 40 feet
(See chart on
page 249)
(See chart on
page 249)
RTSU
Notes:
1 Some restrictions may apply, see
chart on page 249 for details.
2 Specify location and orientation when
ordering option.
For 1st "x":Specify the height in feet
above base of pole.
Use two digits to specify height:
Example: 5 ft = 05 and 20 ft = 20
For 2nd "x":Specify orientation from
handhole (A, B, C, D)
Refer to the Handhole Orientation
diagram on page 249.
3 Horizontal arm is 18" x 2-3/8" O.D.
tenon standard.
4 Other colors available, please contact
your local American Electric Lighting
representative.
248
Product Guide
Options
Mounting / Arm Length1
SMP US4
Single-bolt
simplex mount, 4'
arm length
SMP US6 Single-bolt
simplex mount, 6'
arm length
SMP US8 Single-bolt
simplex mount, 8'
arm length
MSMP US10 Multi-bolt
simplex mount ,
10' arm length
MSMP US12 Multi-bolt
simplex mount ,
12' arm length
Shipped Installed
L/AB Less anchor bolts
FBC Full base cover
VD Vibration damper
TP Tamperproof
HASxx1,2,3 Horizontal arm
Bracket (1 fixture)
FDLxx2 Festoon outlet less
electrical
FGLxx2 Festoon GFI outlet
less electrical
12CPxx2 1/2" coupling
34CPxx2 3/4" coupling
1CPxx2 1" coupling
12NPxx2 1/2" threaded nipple
34NPxx2 3/4" threaded nipple
1NPxx2 1" threaded nipple
HHxx2 Extra handhole
For more information, please visit our website,
www.americanelectriclighting.com
Architectural Colors
(powder finish)4
Standard Colors
GALV Galvanized
Finish (std)
DDB Dark bronze
DWH White
DBL Black
RTSU
Anchor Base Poles / Mounting Arm Combo
Round Tapered Steel Pole with Single Mounting Arm
P R O D U C T
O V E R V I E W
/
O R D E R I N G
I N F O R M AT I O N
Technical Information
EPA (ft2) with 1.3 gust
Fixture Mtg.
Height1
(ft.)
AEL Catalog Number
RTSU 20 5-9B SMP US4
RTSU 20 5-9B SMP US6
RTSU 20 5-9B SMP US8
RTSU 25 5-9B SMP US4
RTSU 25 5-9B SMP US6
RTSU 25 5-9B SMP US8
RTSU 20 6-5B SMP US4
RTSU 20 6-5B SMP US6
RTSU 20 6-5B SMP US8
RTSU 25 7B SMP US4
RTSU 25 7B SMP US6
RTSU 25 7B SMP US8
RTSU 25 7B MSMP US10
RTSU 25 7B MSMP US12
RTSU 30 8B SMP US4
RTSU 30 8B SMP US6
RTSU 30 8B SMP US8
RTSU 30 8B MSMP US10
RTSU 30 8B MSMP US12
RTSU 35 8-5B SMP US4
RTSU 35 8-5B SMP US6
RTSU 35 8-5B SMP US8
RTSU 35 8-5B MSMP US10
RTSU 35 8-5B MSMP US12
RTSU 40 9B SMP US4
RTSU 40 9B SMP US6
RTSU 40 9B SMP US8
RTSU 40 9F MSMP US10
RTSU 40 9F MSMP US12
20
20
20
25
25
25
20
20
20
25
25
25
25
25
30
30
30
30
30
35
35
35
35
35
40
40
40
40
40
Mtg. Arm
length
(ft.)
Pole Base
Diameter
(.14 taper rate)
Wall
Thickness
(in.)
4
6
8
4
6
8
4
6
8
4
6
8
10
12
4
6
8
10
12
4
6
8
10
12
4
6
8
10
12
5.9
5.9
5.9
5.9
5.9
5.9
6.5
6.5
6.5
6.8
6.8
6.8
6.8
6.8
8
8
8
8
8
8.5
8.5
8.5
8.5
8.5
9
9
9
9
9
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.180
0.180
(Max per Arm)
Max Weight
EPA ft2 w/ 1.3 Gust up to per Arm
100 mph
(lbs.)
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
Bolt
Circle
(in.)
Bolt Size
(in.)
9
9
9
9
9
9
9.5
9.5
9.5
10.5
10.5
10.5
10.5
10.5
11
11
11
11
11
11.5
11.5
11.5
11.5
11.5
12.5
12.5
12.5
12.5
12.5
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1 x 36 x 4
1.25 x 42 x 6
1.25 x 42 x 6
Notes:
1. Denotes fixture mounting heights, NOT nominal pole height.
Shaft
Base
Size
Bolt 1
Circle
A
Bolt
Projection
B
Base
Square
C
Anchor
Warehouse Template
Bolt
Anchor Bolt Number
Description Description
5.9" B
6.5" B
7.0" B
8.0" B
8.5" B
9.0" B
9.0" F
9"
9.5"
10"
11"
11.5"
12.5"
12.5"
3-1/2"–4-1/4"
3-1/2"–4-1/4"
3-1/2"–4-1/4"
3-1/2"–4-1/4"
3-3/4"–4-1/2"
3-3/4"–4-1/2"
4-1/2"–5-1/4"
10"
10-1/2"
10-7/8"
11-1/2"
12"
12-3/8"
12-3/8"
ABRTS-5-9B
ABRTS-6-5B
ABRTS-7-0B
ABRTS-8-0B
ABRTS-8-5B
ABRTS-9-0B
ABRTS-9-0F
AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
AB36-0
N/A
PJ50075
PJ50074
PJ50077
PJ50079
PJ50082
PJ50085
PJ50086
IMPORTANT:
• Do not erect poles without having fixtures installed.
• Factory-supplied templates must be used when setting anchor bolts.
American Electric Lighting will not accept claim for incorrect anchorage
placement due to failure to use factory template.
• If poles are stored outside, all protective wrapping must be removed
immediately to prevent finish damage.
• Installation requires grout be packed under base to ensure full contact
with foundation.
A
C
IMPORTANT:
• These specifications are intended for general purposes only. American Electric
Lighting reserves the right to change material or design, without prior notice, in a
continuing effort to upgrade its products.
Product Guide
249
AMAW / SMAW
AMAW: Aluminum Mounting Arm, Wood Poles
SMAW: Steel Mounting Arm, Wood Poles
P R O D U C T
O V E R V I E W
/
O R D E R I N G
I N F O R M AT I O N
Steel: Body is galvanized steel tube (per ASTM A-123) constructed
from A500 Grade B steel. Base is 3/16" plate.
Intended Use
Mounting roadway fixtures to wood poles.
Welding follows AWS standards. Arms are galvanized after fabrication.
Features
Finish: Satin aluminum or galvanized steel is standard. Optional
polyester powder finishes available.
Construction
Hardware not included.
Aluminum: Body is schedule 10 (T14) or schedule 40 (T20) aluminum
pipe 6005-T5. Base is 3/8" aluminum plate.
Welding follows AWS standard. Arms are pressure-washed after
fabrication.
Example: A M A W T 2 0 U S 4 S A A E L
Ordering Information:
Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option
Pipe Size
Series
AMAW
SMAW
T14
T20
Arm Length (feet)
1 - 2/3” O.C. (1 - 1/4” NPS)
2 - 3/8” O.D. (2” NPS)
US2-5
US4
US6
US8
2-1/2' arm length
4' arm length
6' arm length1
8' arm length1
Notes:
1
2
250
Not available with AMAWT14
Other colors available, please
contact your local American
Electric Lighting representative
Product Guide
For more information, please visit our website,
www.americanelectriclighting.com
Options
Standard Finish
SA Satin aluminum
(standard w/ AMAW)
GALV Galvanized steel (standard w/ SMAW)
Architectural Colors (powder finish)2
Standard Colors
DDB Dark bronze
DWH White
DBL Black
AMAW / SMAW
AMAW: Aluminum Mounting Arm, Wood Poles
SMAW: Steel Mounting Arm, Wood Poles
P R O D U C T
O V E R V I E W
/
O R D E R I N G
I N F O R M AT I O N
AMAW / SMAW
AEL Catalog Number
Nominal
Arm Length
(ft.)
Dimensions
(in.)
A
B
C
Weight
(lbs.)
(Max per Arm)
EPA ft2 w/ 1.3 Gust
up to 100mph
Max Weight
per arm
(lbs.)
AMAW T14 US2-5
AMAW T14 US4
AMAW T14 US6
AMAW T20 US2-5
AMAW T20 US4
AMAW T20 US6
AMAW T20 US8
2'6"
4'
6'
2'6"
4'
6'
8'
30
42
66
30
42
66
90
15
19
24
15
10
24
30
10
10
12
10
10
12
15
3
4
6
6
7
10
12
2
2
2
2
2
2
2
76
76
76
76
76
76
76
SMAW T14 US2-5
SMAW T14 US4
SMAW T14 US6
SMAW T14 US8
SMAW T20 US2-5
SMAW T20 US4
SMAW T20 US6
SMAW T20 US8
2'6"
4'
6'
8'
2'6"
4'
6'
8'
30
42
66
90
30
42
66
90
15
19
24
30
15
19
24
30
10
10
12
15
10
10
12
15
9
11
15
20
15
18
24
30
2
2
2
2
2
2
2
2
76
76
76
76
76
76
76
76
IMPORTANT:
CAUTION:
• These specifications are intended for general purposes only. American
Electric Lighting reserves the right to change material or design without
prior notice in a continuing effort to upgrade its products.
• The arms described herein are designed for applications in areas of normal
winds. Consult the factory prior to the design of systems to be mounted on
structures such as bridges or buildings, or areas known to have abnormal
winds such as airports or coastal areas. Failure to consider these factors
in the system design could result in the failure of the pole or mast arm, and
consequently in personal injury or property damage.
A
C
B
.562" Diameter
Product Guide
251
AMAC / SMAC
AMAC: Aluminum Mounting Arm, Concrete Poles
SMAC: Steel Mounting Arm, Concrete Poles
P R O D U C T
O V E R V I E W
/
O R D E R I N G
Intended Use
I N F O R M AT I O N
Steel: Body is galvanized steel tube (per ASTM A-123) constructed
from A500 Grade B steel. Base is 3/16" plate.
Mounting roadway fixtures to concrete poles.
Welding follows AWS standards. Arms are galvanized after fabrication.
Features
Finish: Satin aluminum or galvanized steel is standard. Optional
polyester powder paint finishes available.
Construction
Hardware not included.
Aluminum: Body is schedule 10 (T14) or schedule 40 (T20) aluminum
pipe 6005-T5. Base is 3/8" aluminum plate.
Welding follows AWS standard. Arms are pressure-washed after
fabrication.
Example: A M A C T 2 0 U S 4 S A A E L
Ordering Information:
Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option
Pipe Size
Series
AMAC
SMAC
T14
T20
Arm Length (feet)
1 - 2/3” O.C. (1 - 1/4” NPS)
2 - 3/8” O.D. (2” NPS)
US4
US6
US8
4'arm length
6' arm length1
8' arm length1
Notes:
1 Not available with AMAWT14
2 Other colors available, please contact
your local American Electric Lighting
representative
252
Product Guide
For more information, please visit our website,
www.americanelectriclighting.com
Options
Standard Finish
SA Satin aluminum
(standard w/ AMAW)
GALV Galvanized steel (standard w/ SMAW)
Architectural Colors (powder finish)2
Standard Colors
DDB Dark bronze
DWH White
DBL Black
AMAC / SMAC
AMAC: Aluminum Mounting Arm, Concrete Poles
SMAC: Steel Mounting Arm, Concrete Poles
P R O D U C T
O V E R V I E W
/
O R D E R I N G
I N F O R M AT I O N
AMAW / SMAW
AEL Catalog Number
Nominal
Arm Length
(ft.)
Dimensions
(in.)
A
B
C
Weight
(lbs.)
(Max per Arm)
EPA ft2 w/ 1.3 Gust
up to 100mph
Max Weight
per Arm
(lbs.)
76
AMAC T14 US4
AMAC T20 US4
AMAC T20 US6
AMAC T20 US8
4
4
6
8
42
42
66
90
18
18
24
30
10
10
12
15
6
8
11
14
2
276
2
276
SMAC T14 US4
SMAC T14 US6
SMAC T14 US8
SMAC T20 US4
SMAC T20 US6
SMAC T20 US8
4
6
8
4
6
8
42
66
90
42
18
24
30
18
66
30
10
12
15
10
24
15
13
17
21
18
12
30
2
276
2
2
24
2
90
IMPORTANT:
76
76
76
76
276
76
CAUTION:
• These specifications are intended for general purposes only. American
Electric Lighting reserves the right to change material or design without
prior notice in a continuing effort to upgrade its products.
• The arms described herein are designed for applications in areas of normal
winds. Consult the factory prior to the design of systems to be mounted on
structures such as bridges or buildings, or areas known to have abnormal
winds such as airports or coastal areas. Failure to consider these factors
in the system design could result in the failure of the pole or mast arm, and
consequently in personal injury or property damage.
A
Keyhole
.687" x 1.5"
C
B
.375" GND
Hole
1/4" x 2" HRS. Flat BAR (A36)
or 3.8" x 2" Aluminum Flat Bar (6063)
Slot
.687" x 1.0"
Product Guide
253
SMAWL
Mounting Arm
Steel Mounting Arm, Wall Mount
P R O D U C T
O V E R V I E W
/
O R D E R I N G
Intended Use
I N F O R M AT I O N
Finish galvanized steel is standard. Optional polyester powder paint
finishes available.
Wall-mounting roadway fixtures
Hardware not included.
Features
Construction: Body is galvanized steel tube (per ASTM A-123)
constructed from A500 Grade B steel.
Welding follows AWS standards. Arms are galvanized after
fabrication.
Example: S M A W L T 2 0 U S 4 G A L V A E L
Ordering Information:
Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option
SMAWL
Pipe Size
Series
SMAWL
T14
T20
1 - 2/3” O.C. (1 - 1/4” NPS)
2 - 3/8” O.D. (2” NPS)
US2-5
US4
US6
US8
Arm Length (feet)
Options
2-1/2'arm length
4'arm length
6' arm length1
8' arm length1
Standard Finish
GALV Galvanized steel (standard w/ SMAW)
Architectural Colors (powder finish)2
Standard Colors
DDB Dark bronze
DWH White
DBL Black
Notes:
1
2
254
Not available with AMAWT14.
Other colors available, please
contact your local American
Electric Lighting representative.
Product Guide
For more information, please visit our website,
www.americanelectriclighting.com
SMAWL
Mounting Arm
Steel Mounting Arm, Wall Mount
P R O D U C T
O V E R V I E W
/
O R D E R I N G
I N F O R M AT I O N
AMAW / SMAW
AEL Catalog Number
Nominal
Arm Length
(ft.)
SMAWL T14 US2-5
SMAWL T14 US4
SMAWL T14 US6
SMAWL T20 US2-5
SMAWL T20 US4
SMAWL T20 US6
SMAWL T20 US8
2’6"
4'
6'
2'6"
4'
6'
8'
Dimensions
(inches)
A
B
C
30
42
66
30
42
15
19
24
15
19
66
30
10
10
12
10
10
24
15
90
Weight
(pounds)
(Max per arm)
EPA ft2 w/ 1.3 gust
up to 100mph
Max Weight
per arm
(lbs)
11
13
18
17
22
12
38
2
2
2
2
2
30
2
76
76
76
76
76
276
76
IMPORTANT:
CAUTION:
• These specifications are intended for general purposes only. American
Electric Lighting reserves the right to change material or design without
prior notice in a continuing effort to upgrade its products.
• The arms described herein are designed for applications in areas of normal
winds. Consult the factory prior to the design of systems to be mounted on
structures such as bridges or buildings, or areas known to have abnormal
winds such as airports or coastal areas. Failure to consider these factors
in the system design could result in the failure of the pole or mast arm, and
consequently in personal injury or property damage.
.562 Diameter
(4 PLCS.)
A
1"
C
1"
1/4" Plate
14"
12"
B
1/4" x 2" Flat Bar
2"
4"
Product Guide
255
Options & Accessories
Mast Arms & Brackets - Upsweep Arms
(For Horizontally Mounted Luminaires)
P R O D U C T
O V E R V I E W
/
O R D E R I N G
I N F O R M AT I O N
Wood Pole Mounting
Catalog
Number
91-2401
A
92-2401
B
92-3001
C
92-3001
92-4801
92-4801
A
92-4802
92-4802
B
92-7201
C
92-7202
92-7202
92-9602
92-7201
A
92-2401
92-7202
B
C
94-9601
93-9602
256
Product Guide
Item
2' ARM -11/4 '' Aluminum, (Use with Nema Head only)
Dimensions: A-24'', B-123/4'', C-73/8''
2' ARM -11/4'' Steel, Class E
Dimensions: A-24'', B-123/4'', C- 73/8''
21/2' ARM -11/4'' Aluminum, (Use with NEMA head only)
Dimensions: A-27'', B-123/4'', C-73/8''
21/2' ARM -11/4'' Steel, Class E
Dimensions: A-27'', B-123/4'', C-73/8''
4' ARM -11/4'' Aluminum, Class B
Dimensions: A-43'', B-213/4'', C-87/8''
4' ARM -11/4'' Steel, Class E
Dimensions: A-43'', B-211/2'', C-85/8''
4' ARM -2'' Aluminum, Class D
Dimensions: A-43'', B-211/4'', C-85/8''
4' ARM -2'' Steel, Class E
Dimensions: A-43'', B-211/2'', C-87/8''
6' ARM -11/4'' Steel, Class C
Dimensions: A-661/4'', B-291/2'', C-83/8''
6' ARM -2'' Aluminum, Class B
Dimensions: A-661/4'', B-291/2'', C-83/8''
6' ARM -2'' Steel, Class D
Dimensions: A-661/4'', B-291/2'', C-83/4''
8' ARM -2'' Steel, Class D
Dimensions: A-901/4'', B-297/8'', C-81/2''
6' ARM -11/4'' Aluminum, Class B
Dimensions: A-661/4'', B-291/2'', C-83/4''
6' ARM -11/4'' Steel, Class E
Dimensions: A-661/4'', B-291/2'', C-83/4''
6' ARM -2'' Aluminum, Class D
Dimensions: A-661/4'', B-29'', C-77/8''
8' ARM -11/4'' Steel, Class C
Dimensions: A-901/4'', B-291/2'', C-83/4''
8' ARM -2'' Aluminum, Class B
Dimensions: A-901/4'', B-291/2'', C-77/8''
For more information, please visit our website,
www.americanelectriclighting.com
Approx.
Wt. (lbs.)
1-3/4
5-1/2
2
6
3-3/4
10
6-1/2
17-1/2
17-1/2
9
25-1/2
40
6-3/4
18
11
26-1/2
13-1/2
Options & Accessories
Mast Arms & Brackets - Upsweep Arms
(For Horizontally Mounted Luminaires)
P R O D U C T
O V E R V I E W
/
O R D E R I N G
I N F O R M AT I O N
Concrete Pole Mounting
Catalog
Number
Item
90-2001
90-4801
D
B
C
20” ARM -1¼'' Steel, Class E
Dimensions: A-20'', B-15'', C-12''
4' ARM -1¼'' Steel, Class E
Dimensions: A-48'', B-25'', C-12''
6' ARM -2'' Steel, Class D
Dimensions: A-72'', B-34'', C-12''
8' ARM -2'' Steel, Class D
Dimensions: A-96'', B-34'', C-12''
Mounting
Bracket
90-7202
90-9602
A
Approx.
Wt. (lbs.)
10
16
29
48
Notes:
1. CLASS CHART — Denotes the maximum size luminaire recommended for use. Both weight and
projected area must be considered. Classifications based on American Electric Lighting standards. See
Isotach Wind Map, page 215.
Luminaire Class
Weight (in pounds)
Effective Projected Area
A
30
1.5
B
40
2.0
C
60
3.0
D
80
4.0
E
100
5.0
2. Steel mast arms constructed in accordance with ASTM specification A-36.
3. For more information, please contact your local American Electric Lighting representative.
CAUTION:
• The poles and mast arms described herein are designed for ground mounted
applications in areas of normal winds. Consult the factory prior to the design
of systems to be mounted on structures such as bridges or buildings, or
areas known to have abnormal winds such as airports or coastal areas.
Failure to consider these factors in the system design could result in the
failure of the pole or mast arm, and consequently personal injury or property
damage.
Product Guide
257
258
Product Guide
American Electric Lighting
TM
FREQUENTLY ORDERED PRODUCTS
ROADWAY LIGHTING
Roadway Series 125
TM
DuraStar Series 20
20 10S RN 120 R3 FG
20 15S RN 120 R3 FG
TM
DuraStar Series 30
30 25S CA MT1 R2 FG
30 40S CA MT1 R3 FG LC PC
125 25S CA MT1 R3 DG
125 40M CA MT1 R3 DG
125 40S CA MT1 R3 DG
Roadway Series 125 Cutoff
125 25S CA MT1 R3 FG
125 40S CA MT1 R3 FG
125 25S MR 120 R3 FG
Roadway Series 325
Roadway Series 115
115 10S RN 120 R2 DA
115 15S RH 120 R2 DA
115 25S CA MT1 R3 DG
325 40M CA MT1 R3 DG
325 40S CA MT1 R3 DG
Roadway Series 115 Cutoff
115 10S RN 120 R3 FG
115 10S CA MT1 R2 FG LC PC
115 15S MR 120 R3 FG 4B
Roadway Series 325 Cutoff
325 25S CA MT1 R3 FG LC PC
325 25S MR DT1 R3 FG
Roadway Series 315
Roadway Series 327
315 25S CA MT1 R2 DG 4B
315 10S XH MT2 R3 DA 4B
Roadway Series 315 Cutoff
315 15S RH 120 R3 FG
315 10S CA MT1 R2 FG LC PC
327 X1M CA MT1 R3 DG
327 X1M CA 480 R3 DG
Roadway Series 413
413 10S RN 120 R3 FG
Product Guide 259
American Electric Lighting
TM
FREQUENTLY ORDERED PRODUCTS
Multi-Mount TM Series 285
285 40S CA MT1 R3 DA GY
UnderPass Series 581/681
581 25M CA MT1 LC
681 10S RN 120 LC
Heavy-Duty Wall Pack Series 882
InterState TM II Series 775
775 40S CA MT1 R3 FG
882 40M CA MT1 LC
Signlite Series 875
LPS Roadway Series SRP
SRP 13L XH DT1 R4 DA LC PC
875 40M CA MT1 66 FG LC
DECORATIVE AND POST-TOP LIGHTING
LPS Roadway Series SRX
SRX 55L XH DT1 R4 DP LC
LPS Roadway Series SP2
SP2 09L XH DT1 R4 DP LC PC
SP2 13L XH DT1 R4 DP LC PC
SP2 18L XH DT1 R4 DP LC PC
UnderPass Series GST
GST 55L XH DT1 R1 DP LC
260
Product Guide
Heritage Collection Marietta Series LMD
LMD 10S CA MT1 R3 PA PR US
LMD 17M CA MT1 R3 PA PR US
LMD 10S CA MT1 R5 PA PR US
LMD 17M CA MT1 R5 PA PR US
Heritage Collection Sumter Series LSH
LSH 10S CA MT1 R5 PA PR
LSH 17M CA MT1 R5 PA PR
Heritage Collection Cresthill Classic Series LCR
LCR 10S CA MT1 R0 AP PR
LCR 17M CA MT1 R0 AP PR
LCR 17M CA MT1 R3 AP PR
LCR 10S CA MT1 R5 AP PR
For photometric information, visit our website,
www.americanelectriclighting.com
American Electric Lighting
TM
FREQUENTLY ORDERED PRODUCTS
Heritage Collection Cresthill Sphere Series LCR
LCR 10S CA MT1 R0 SY PR
LCR 15S CA MT1 R0 SY PR
LCR 17M CA MT1 R0 SY PR
Heritage Collection Yorktown Series LYT
LYT 10S RN 120 R5 PY BC
LYT 15S RN 120 R5 PY BC
LYT 17M CA MT1 R5 PY BC
Heritage Collection Cresthill Centennial Series LCR
LCR 10S CA MT1 R5 CW PR
LCR 15S CA MT1 R5 CW PR
LCR 17M CA MT1 R5 CW PR
Heritage Collection Branson Series LBR
LBR 10S CA MT1 R3 AY PR
LBR 15S CA MT1 R3 AY PR
Heritage Collection Cresthill Glass Series LCR
LCR 10S CA MT1 R3 PG PR
LCR 17M CA MT1 R3 PG PR
LCR 17M CA MT1 R5 PG PR
Heritage Collection Depot Series LDP
LDP 15S RN 120 R0 PY BC
Heritage Collection Lexington Series LLX
LLX 10S CA MT1 R5 PY PR
LLX 17M CA MT1 R5 PY PR
American Revolution Series 247
247 10S RN 120 R3 AY
247 10S RN 120 R5 AY
247 15S RN 120 R3 AY
247 17V XN 120 R3 AY
Heritage Collection Syracuse Series LSY
LSY 10S CA MT1 R5 PY PR
LSY 17M CA MT1 R5 PY PR
Contempo Series 245
Heritage Collection Victorian Series LVI
LVI 10S RN 120 R3 PY PR
LVI 17M CA MT1 R3 PY PR
Residential Post Series RES
RES 07S RN 120 R5 PY
245 10S RN 120 R5 AY
245 15S RN 120 R5 AY
245 17V XN 120 R5 AY
Product Guide 261
American Electric Lighting
TM
FREQUENTLY ORDERED PRODUCTS
Series 110
TwistPack Series TWT
TWT 10S RN 120 R5 AY H4 LC PC
TWT 17M CA MT1 R5 AY H8 NR LC
110 10S RN 120 R1
110 15S RN 120 R1
110 17V XN 120 R1
Dusk to Dawn Series DTD
Bainbridge Series 870
870 17M CA MT1 R5 AY LC BC
870 10S RN 120 R5 AY LC BC
SECURITY LIGHTING
DTD 25V CA 120 R5 BA CS LC NL PC
DTD 40V CA 120 R5 BA CS LC NL PC
Series 165
315 Series
165 20S XN 120 R5 BA PJ0 LC
165 40V XN 120 R5 BG LC LC
315 07S CA MT1 R5 BA EC PK
315 10S CA MT1 R5 BA EC PK
315 15S CA MT1 R5 BA EC PK
315 17M CA MT1 R5 BA PK
315 17V CA MT1 R5 BA PK
AREA LIGHTING
AVL
NEMA Head Series 11
AVL X1M CA MT1 SM DG P2 A4 TL
AVL 40M CA MT1 SM DG P2 A4 TL
11 10S RN 120 RO LO
11 10S RN 120 R5 BA
11 17V XN 120 RO LO
11 17V XN 120 R5 BA
NEMA Head Package Series 11 PKG
11PKG 10S RN 120 R5 BA DPC EC
11PKG 15S RN 120 R5 BA DPC EC
11PKG 17V XN 120 R5 BA DPC
LuxMaster® Luminaire 53
Series 11 “L” Package
LuxMaster® Luminaire 153
53 15S CA MT1 R2 FG
53 15S RN 120 R2 FG
11L 10S RN 120 R5 BA
11L 15S RN 120 R5 BA
11L 17V XN 120 R5 BA
11L 17V RN 240 R5 BA
262
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
153 25S CA MT1 R3 FG
153 40S CA MT1 R3 FG
153 40M CA MT1 R3 FG
American Electric Lighting
TM
FREQUENTLY ORDERED PRODUCTS
LuxMaster® Classic Series LS
LS 10S CA 120 R3 NR
LS 10S R3 HSG NR
LMP BZ
UltraFlood™ Series 75
LuxMaster® Classic Series LM
LM 40M CA MT1 R3 NR
LM 40M R3 HSG NR
LMP BZ
UltraFlood™ Series 77
LuxMaster® Classic Series LL
LL X1M CA MT1 R3 NR
LL XIM R3 HSG NR
LMP BZ
Quartz Flood Series 570
LuxMaster® Luminaire LML
LML 18L XH MTI R1 FP
Quartz Flood Series 474
FLOODLIGHTING
AmeriSport™ Series ASP
75 25S CA MT1 76 0443
75 40M CA MT1 76 0443
75 40M CA MT1 66 0443
75 40S CA MT1 76 0443
77 X1M CA MT1 76 0443
77 X1M CA MT1 76 0443 TL NL
77 X1S CA MT1 65 0443
570 61/L
474-61/L-240V
474-61/L-277V
ASP X5M CA MT1 GM 0343
ASP X5M CA MT1 GW 0343
Compact Flood Series 51
51 10S RH 120 77 TB 0643 NL TL
51 17M CA MT1 76 TB NL TL
51 20S CA 120 76 TB OP 0643 NL TL
51 40S CA MT1 76 TB OP 0643 NL TL
Sportslighting Series SPF
SPF X5M CA MT1 44 0343
SPF X5M CA MT1 55 0343
SPF X5M CA MT1 66 0343
Product Guide 263
American Electric Lighting
TM
FREQUENTLY ORDERED PRODUCTS
DARK TO LIGHT PHOTOCONTROLS
DUX Series Basic, UL Listed
DUX124-12A J50
DE Series Filtered Silicon
DE124-1.0-TM J50
DE480-1.5-TJ J50
DE120-1.5-TJ J50
DBE Series Button
DD Series Diagnostic
DD124-1.5-TMA J50
DBE120-1.5-T J25
DBE240-1.5-T J25
DB Series Button
DPN Series Part Night®
DPN124-2.6-TMGN J50
DP Series Silicon
DP120-1.5-TM J50
DP120-1.5-TMBK J50
DP124-1.5-TJ J50
DP124-1.5-1704 J50
D Series Cadmium Sulphide
D120-1.0-STM J50
D214-1.5-STM J50
DB120-1.5-ST J25
D779 Series, Industry Standard
D7790 J12
D7790 J50
Shorting Caps
DX Series Basic
DX120-12A J50
DX124-12A J50
264
Product Guide
For photometric information, visit our website,
www.americanelectriclighting.com
D-SHORT-SBK J12
ACCESSORIES, TECHNICAL DATA, TERMS & CONDITIONS
HPS Replacement Starters...................................266
Lamp Selection .......................................................267
Fuse Ratings ....................................................268-273
Luminaire Classification Systems........................274
Floodlighting Applications. ...................................275
Floodlighting Calculations.....................................276
Location/Aiming Guidelines..................................276
Roadway Lighting Calculations............................277
Terms & Conditions ........................................278-279
Index .................................................................280-281
Product Guide
265
Accessories
H P S
R E P L A C E M E N T
S TA R T E R S
Catalog Number
Description
IGN 3L 36 OB 50/150
3 Lead 3/16” Terminal Open Board 55V
IGN 3L 36 OB 200/400
3 Lead 3/16” Terminal Open Board 100V
IGN 3L 14 OP 50/150
3 Lead 1/4” Terminal Open Plug 55V
IGN 3L 14 OP 200/400
3 Lead 1/4” Terminal Open Plug 100V
IGN 3L 14 EC 50/150
3 Lead 1/4” Terminal Encapsulated 55V
IGN 3L 14 EC 200/400
3 Lead 1/4” Terminal Encapsulated 100V
IGN 2L 36 OB 50/150
2 Lead 3/16” Terminal Open Board 55V
IGN 2L 36 OB 200/400
2 Lead 3/16” Terminal Open Board 100V
IGN 2L 14 OP 50/150
2 Lead 1/4” Terminal Open Plug 55V
IGN 2L 14 OP 200/400
2 Lead 1/4” Terminal Open Plug 100V
IGN 2L 14 EC 50/150
2 Lead 1/4” Terminal Encapsulated 55V
IGN 2L 14 EC 200/400
2 Lead 1/4” Terminal Encapsulated 100V
IGN 2L 36 OB DUAL 50/400
IGN 2L 14 OP DUAL 50/400
2 Lead 3/16” Terminal Open Board Dual 55/100V1
2 Lead 1/4” Terminal Open Plug Dual 55/100V1
IGN 2L 14 EC DUAL 50/400
2 Lead 1/4” Terminal Encapsulated Dual 55/100V1
IGN 2L 14 EC DUAL UNI
2 Lead 1/4” Terminal Encapsulated Dual Universal
IGN 2L 14 OP DUAL UNI
2 Lead 1/4” Terminal Open Plug Dual Universal
Notes:
1
266
Product Guide
Ships as 55V, converts to 100V by removing jumper wire
Applications & Design
L A M P
S E L E C T I O N
Typical Lamp Types
with Watts, Initial Lamp Lumens
and Light Loss Factors
Lamp Comparison
Quartz
Incandescent
Mercury
Vapor
Low Pressure
Sodium
Metal
Halide
High Pressure
Sodium
Efficiency
Poor
20 LPW
Fair
56 LPW
Best
183 LPW
Good
100 LPW
Better
125 LPW
Mean Life
Low
2K Hrs
High
24K Hrs
Medium
18K Hrs
High
20K Hrs
High
24K Hrs
Lumen
Maintenance
High
97%
Poor
57%
High
100%(+9)
Medium
80%
High
90%
Color
Good
Poor
Good
Poor
Monochrome
Excellent
Acceptable
System C.U.
Good
Good
Fair
Good
Good
Hot Restart
Instant
10 Minutes
1 Minute
15 Minutes
1 Minute
Warm-Up
Instant
10 Minutes
10 Minutes
10 Minutes
5 Minutes
System Cost
Lowest
Medium
High
High
High
Lamp
Type
High
Pressure
Sodium
Metal
Halide
Recommended Minimum Mounting Heights
for Various Lamps
High Pressure
Sodium Lamp
50W
70W
100W
150W
200W
250W
310W
400W
1000W
Mercury
Vapor Lamp
Metal Halide
Lamp
100W
175W
175W
400W
400W
1000W
1000W
Minimum Mounting
Height (ft.)
8.0
12.0
15.0
18.0
20.0
25.0
30.0
35.0
40.0
Maintenance Factors
If maintained footcandle level is desired, multiply the area coverage
per fixture by the maintenance factor.
Maintenance factor is determined by multiplying the lamp lumen
depreciation factor (LLD) by the luminaire dirt depreciation factor
(LDD). The lamp lumen depreciation factor usually is the mean lumen
value of the lamp. The luminaire dirt depreciation factor range is
described in the Illuminating Engineering Society Handbook. A .9 dirt
factor commonly is used.
Mercury
Vapor
Pulse
Start
Metal
Halide
High
Pressure
Sodium
with
Internal
Ignitor
Watts
Initial
Lumens
Mean
Lumens
Avg. Life
35
50
70
100
150
200
250
310
400
1000
2250
4000
6300
9500
16000
22000
28500
37000
50000
125000
2025
3600
5670
8550
14400
19800
25600
33300
45000
112000
24000
24000
24000
24000
24000
24000
24000
24000
24000
24000
50
70
100
150
175
250
400
1000
15000
3750
6000
9000
13500
13500
20500
36000
110000
165000
2800
4800
7200
9450
8775
13500
24000
71000
132000
15000
15000
15000
9000
10000
10000
20000
120000
3000
175
175
400
700
1000
16000
12100
21000
43000
57500
7400
10500
18900
33600
48400
24000
24000
24000
24000
24000
175
250
320
350
400
1000
16000
23800
31700
3700
44000
120000
112000
16600
23140
28000
31000
96000
150000
15000
15000
20000
20000
20000
3600
5400
8550
14400
19800
25600
33000
45000
126000
28500
28500
28500
28500
28500
28500
28500
28500
28500
50
70
100
150
200
250
310
400
1000
4000
6000
9500
16000
22000
28500
37000
50000
140000
Product Guide
267
Accessories
F U S E
R AT I N G S
Nominal
Lamp
Wattage
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
07S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10S
10V
10V
10V
10V
Ballast
Circuit
Supply
Voltage
Input
Watts
RN
RH
XN
XN
XN
XH
XH
XH
CA
CA
CA
CA
CA
CT
CT
CT
MR
MR
MR
RN
RH
XN
XN
XN
XH
XH
XH
CA
CA
CA
CA
CA
CA
CT
CT
CT
MR
MR
MR
XN
XH
CT
CT
120
120
208
240
277
208
240
277
120
208
240
277
480
120
208
240
120
240
480
120
120
208
240
277
208
240
277
120
208
240
277
347
480
120
208
240
120
240
480
120
120
120
240
86
86
91
91
91
91
91
91
95
95
95
95
95
95
95
95
103
103
103
115
115
130
130
130
130
130
130
138
138
138
138
138
138
130
130
130
138
138
138
125
125
125
125
Current
(amps)
2.10
1.30
1.53
1.35
1.17
0.85
0.75
0.65
0.90
0.53
0.48
0.43
0.23
0.86
0.50
0.43
0.90
0.45
0.23
3.05
1.80
2.25
1.98
1.53
1.25
1.10
0.85
1.18
0.70
0.60
0.50
0.40
0.29
1.22
0.70
0.61
1.20
0.60
0.30
3.60
2.00
1.05
0.52
Notes:
1
268
Product Guide
Based on $.10/KWH; 12 months operation
# of Fuses
1
1
2
2
1
2
2
1
1
2
2
1
2
1
2
2
1
2
2
1
1
2
2
1
2
2
1
1
2
2
1
1
2
1
2
2
1
2
2
1
1
1
2
Annual
Fuse
Rating
(amps)
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
10
5
10
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
10
5
5
5
Energy
Consumption
($)1
$37.67
$37.67
$39.86
$39.86
$39.86
$39.86
$39.86
$39.86
$41.61
$41.61
$41.61
$41.61
$41.61
$41.61
$41.61
$41.61
$45.11
$45.11
$45.11
$50.37
$50.37
$56.94
$56.94
$56.94
$56.94
$56.94
$56.94
$60.44
$60.44
$60.44
$60.44
$60.44
$60.44
$56.94
$56.94
$56.94
$60.44
$60.44
$60.44
$54.75
$54.75
$54.75
$54.75
Accessories
F U S E
Nominal
Lamp
Wattage
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
15S
17V
17V
17V
17V
17V
17V
17V
17V
17V
17V
17V
17V
17M
17M
17M
17M
17M
17M
17M
17M
17M
17M
17M
17M
Ballast
Circuit
Supply
Voltage
Input
Watts
RN
RH
XN
XN
XN
XH
XH
XH
CA
CA
CA
CA
CA
CT
CT
CT
CT
MR
MR
MR
RN
RH
RN
RH
XN
XH
CA
CA
CA
CA
CA
CA
CA
CA
CA
CA
CA
CA
SC
SC
SC
SC
SC
SC
120
120
208
240
277
208
240
277
120
208
240
277
480
120
208
240
277
120
240
480
240
240
277
277
120
120
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
170
170
188
188
188
188
188
188
190
190
190
190
188
190
190
190
190
196
196
196
195
195
195
195
200
200
213
213
213
213
213
213
213
213
213
213
213
213
208
208
208
208
208
206
Current
(amps)
4.50
2.35
2.88
2.52
2.25
1.60
1.40
1.25
1.65
0.95
0.82
0.72
0.42
1.76
1.01
0.88
0.76
1.70
0.90
0.40
2.70
1.50
2.34
1.17
6.00
3.33
1.80
1.10
0.90
0.78
0.62
0.51
1.80
1.10
0.90
0.78
0.62
0.51
1.80
1.05
0.90
0.80
0.65
0.45
# of Fuses
1
1
2
2
1
2
2
1
1
2
2
1
2
1
2
2
1
1
2
2
2
2
1
1
1
1
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
Annual
Fuse
Rating
(amps)
15
10
10
10
10
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
10
5
10
5
15
10
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
R AT I N G S
Energy
Consumption
($)1
$74.46
$74.46
$82.34
$82.34
$82.34
$82.34
$82.34
$82.34
$83.22
$83.22
$83.22
$83.22
$82.34
$83.22
$83.22
$83.22
$83.22
$85.85
$85.85
$85.85
$85.41
$85.41
$85.41
$85.41
$87.60
$87.60
$93.29
$93.29
$93.29
$93.29
$93.29
$93.29
$93.29
$93.29
$93.29
$93.29
$93.29
$93.29
$91.10
$91.10
$91.10
$91.10
$91.10
$90.23
Notes:
1
Based on $.10/KWH; 12 months operation
Product Guide
269
Accessories
F U S E
R AT I N G S
Nominal
Lamp
Wattage
20S
20S
20S
20S
20S
20S
20S
20S
20S
20S
20S
20S
20S
20S
20S
20S
20S
20S
20M
20M
20M
20M
20M
20M
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
25S
Ballast
Circuit
Supply
Voltage
Input
Watts
XN
XH
RN
RH
CA
CA
CA
CA
CA
CA
CT
CT
CT
CT
CT
MR
MR
MR
SC
SC
SC
SC
SC
SC
XN
XH
RN
RH
CA
CA
CA
CA
CA
CA
CT
CT
CT
CT
CT
CT
MR
MR
120
120
240
240
120
208
240
277
347
480
120
208
240
277
480
120
240
480
120
208
240
277
347
480
120
120
240
240
120
208
240
277
347
480
120
208
240
277
347
480
120
240
240
240
218
218
240
240
240
240
240
240
235
235
235
235
235
255
255
255
232
232
232
232
232
232
287
287
282
282
295
295
295
295
295
310
300
300
300
300
300
300
310
310
Current
(amps)
6.27
3.48
2.80
1.56
2.22
1.28
1.11
0.96
0.77
0.56
2.10
1.21
1.05
0.91
0.52
2.20
1.10
0.55
2.00
1.20
1.00
0.85
0.70
0.50
8.73
4.85
4.00
2.22
2.50
1.50
1.30
1.10
0.93
0.63
2.75
1.60
1.38
1.19
0.92
0.69
2.80
1.40
Notes:
1
270
Product Guide
Based on $.10/KWH; 12 months operation
# of Fuses
1
1
2
2
1
2
2
1
1
2
1
2
2
1
2
1
2
2
1
2
2
1
1
2
1
1
2
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
Annual
Fuse
Rating
(amps)
20
10
10
5
10
5
5
5
5
5
10
5
5
5
5
10
5
5
5
5
5
5
5
5
30
15
10
10
10
5
5
5
5
5
10
5
5
5
5
5
10
5
Energy
Consumption
($)1
$105.12
$105.12
$95.48
$95.48
$105.12
$105.12
$105.12
$105.12
$105.12
$105.12
$102.93
$102.93
$102.93
$102.93
$102.93
$111.69
$111.69
$111.69
$101.62
$101.62
$101.62
$101.62
$101.62
$101.62
$125.71
$125.71
$123.52
$123.52
$129.21
$129.21
$129.21
$129.21
$129.21
$135.78
$131.40
$131.40
$131.40
$131.40
$131.40
$131.40
$135.78
$135.78
Accessories
F U S E
Nominal
Lamp
Wattage
25S
25V
25V
25V
25V
25V
25V
25V
25V
25V
25V
25V
25V
25V
25M
25M
25M
25M
25M
25M
25M
25M
25M
25M
25M
25M
25M
31S
31S
31S
31S
31S
31S
31S
31S
32M
32M
32M
32M
32M
32M
40S
Ballast
Circuit
Supply
Voltage
Input
Watts
MR
RN
RH
XN
XH
CA
CA
CA
CA
CA
CA
CT
CT
CT
CA
CA
CA
CA
CA
CA
CT
CT
CT
SC
SC
SC
SC
CA
CA
CA
CA
CA
MR
MR
MR
SC
SC
SC
SC
SC
SC
RN
480
240
240
120
120
120
208
240
277
347
480
120
240
480
120
208
240
277
347
480
120
240
480
120
208
240
277
120
208
240
277
480
120
240
480
120
208
240
277
347
480
208
310
274
274
285
285
298
298
298
298
295
295
295
295
295
298
298
298
298
295
295
295
295
295
291
291
291
291
365
365
365
365
365
380
380
380
368
368
368
368
368
368
440
Current
(amps)
0.70
3.00
1.67
6.85
3.81
2.50
1.45
1.25
1.10
0.90
0.63
2.66
1.54
1.33
2.50
1.45
1.25
1.10
0.90
0.63
2.66
1.54
1.33
2.50
1.45
1.25
1.10
3.37
1.94
1.68
1.45
0.84
3.30
1.65
0.83
3.25
1.90
1.65
1.40
1.10
0.80
5.20
# of Fuses
2
2
2
1
1
1
2
2
1
1
2
1
2
2
1
2
2
1
1
2
1
2
2
1
2
2
1
1
2
2
1
2
1
2
2
1
2
2
1
1
2
2
Annual
Fuse
Rating
(amps)
5
10
5
20
10
10
5
5
5
5
5
10
5
5
10
5
5
5
5
5
10
5
5
10
5
5
5
10
5
5
5
5
10
5
5
10
5
5
5
5
5
15
R AT I N G S
Energy
Consumption
($)1
$135.78
$120.01
$120.01
$124.83
$124.83
$130.52
$130.52
$130.52
$130.52
$129.21
$129.21
$129.21
$129.21
$129.21
$130.52
$130.52
$130.52
$130.52
$129.21
$129.21
$129.21
$129.21
$129.21
$127.46
$127.46
$127.46
$127.46
$159.87
$159.87
$159.87
$159.87
$159.87
$166.44
$166.44
$166.44
$161.18
$161.18
$161.18
$161.18
$161.18
$161.18
$192.72
Notes:
1
Based on $.10/KWH; 12 months operation
Product Guide
271
Accessories
F U S E
R AT I N G S
Nominal
Lamp
Wattage
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40S
40V
40V
40V
40V
40V
40V
40V
40V
40V
40V
40V
40V
40V
40V
40M
40M
40M
40M
40M
40M
40M
40M
40M
40M
Ballast
Circuit
Supply
Voltage
Input
Watts
RH
RN
RH
XN
XH
CA
CA
CA
CA
CA
CA
CT
CT
CT
CT
CT
CT
MR
MR
MR
XN
XH
CA
CA
CA
CA
CA
CA
CT
CT
CT
CT
CT
CT
CA
CA
CA
CA
CA
CA
CT
CT
CT
CT
208
240
240
120
120
120
208
240
277
347
480
120
208
240
277
347
480
120
240
480
120
120
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
440
440
440
463
463
464
464
464
464
464
464
465
465
465
465
465
465
490
490
490
440
440
458
458
458
458
460
462
465
465
465
465
462
465
458
458
458
458
460
462
465
465
465
465
Current
(amps)
2.89
6.00
3.33
6.70
3.72
3.80
2.20
1.90
1.70
1.32
0.97
4.20
2.40
2.10
1.82
1.45
1.05
4.20
2.10
1.05
17.00
9.44
4.00
2.30
2.00
1.75
1.40
1.00
4.00
2.31
2.00
0.87
1.35
1.00
4.00
2.30
2.00
1.75
1.40
1.00
4.00
2.31
2.00
0.87
Notes:
1
272
Product Guide
Based on $.10/KWH; 12 months operation
# of Fuses
2
2
2
1
1
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
Annual
Fuse
Rating
(amps)
10
15
10
20
10
10
10
5
5
5
5
15
10
10
5
5
5
15
10
5
N/A
30
10
10
5
5
5
5
10
10
5
5
5
5
10
10
5
5
5
5
10
10
5
5
Energy
Consumption
($)1
$192.72
$192.72
$192.72
$202.79
$202.79
$203.23
$203.23
$203.23
$203.23
$203.23
$203.23
$203.67
$203.67
$203.67
$203.67
$203.67
$203.67
$214.62
$214.62
$214.62
$192.72
$192.72
$200.60
$200.60
$200.60
$200.60
$201.48
$202.36
$203.67
$203.67
$203.67
$203.67
$202.36
$203.67
$200.60
$200.60
$200.60
$200.60
$201.48
$202.36
$203.67
$203.67
$203.67
$203.67
Accessories
F U S E
Nominal
Lamp
Wattage
40M
40M
40M
40M
40M
40M
75S
75S
75S
75M
75M
75M
75M
75M
75M
75M
X1S
X1S
X1S
X1S
X1S
X1S
X1M
X1M
X1M
X1M
X1M
X1M
X1M
X1M
X1M
X1M
X1M
X1M
X5M
X5M
X5M
X5M
X5M
X5M
Ballast
Circuit
Supply
Voltage
Input
Watts
CT
CT
SC
SC
SC
SC
CA
CA
CA
CA
CA
CA
CA
SC
SC
SC
CA
CA
CA
CA
CA
CA
CA
CA
CA
CA
CA
CA
SC
SC
SC
SC
SC
SC
CA
CA
CA
CA
CA
CA
347
480
120
208
240
277
120
208
240
820
820
820
820
120
208
240
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
462
465
452
452
452
452
840
840
840
120
208
240
277
812
812
812
1100
1100
1100
1100
1100
1100
1070
1070
1070
1070
1070
1080
1080
1080
1080
1080
1080
1070
1605
1605
1605
1605
1615
1625
Current
(amps)
1.35
1.00
3.80
2.20
1.90
1.65
6.75
4.00
3.50
6.90
3.85
3.45
3.00
7.00
4.00
3.50
9.50
5.50
4.75
4.15
3.30
2.30
9.00
5.20
4.50
3.90
3.20
2.25
9.00
5.20
4.50
3.90
3.20
2.25
13.50
7.80
6.75
5.58
4.80
3.40
# of Fuses
1
2
1
2
2
1
1
2
2
1
2
2
1
1
2
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
Annual
Fuse
Rating
(amps)
5
5
10
10
5
5
20
10
10
20
10
10
10
20
10
10
30
15
15
15
10
10
30
15
15
10
10
10
30
15
15
10
10
10
N/A
20
20
15
15
10
R AT I N G S
Energy
Consumption
($)1
$202.36
$203.67
$197.98
$197.98
$197.98
$197.98
$367.92
$367.92
$367.92
$52.56
$91.10
$105.12
$121.33
$355.66
$355.66
$355.66
$481.80
$481.80
$481.80
$481.80
$481.80
$481.80
$156.222
$156.222
$156.222
$156.222
$156.222
$157.682
$157.682
$157.682
$157.682
$157.682
$157.682
$156.222
$234.332
$234.332
$234.332
$234.332
$235.792
$237.252
Notes:
1
2
Based on $.10/KWH; 12 months operation
Based on $.10/KWH; 4 months operation
Product Guide
273
Applications & Design
L U M I N A I R E
C L A S S I F I C AT I O N
WIDTH
CLASSIFICATION
Mounted at
Pavement
Type I
Center
Type II
Edge
Normally Used for:
S Y S T E M S
TYPE I
Roadways up to 2 times the
mounting height in width
Up to 1 times the mounting height
for one side mounting
Up to 2 times the mounting height
for both side mounting
Type III
Edge
Up to 1.5 times the mounting
height for one side mounting
Up to 3 times the mounting height
for both side mounting
Type IV
Edge
Up to 2 times the mounting height
for one side mounting
Up to 4 times the mounting height
for both side mounting
Type V
Center
Up to 4 times the mounting height
in total width
TYPE I - 4 Way
TYPE II
TYPE II - 4 Way
274
SPACING
CLASSIFICATION
Definition
S
Short
M
Medium
Spacings up to 5 times mounting
height
L
Long
Spacings up to 5 times mounting
height
GLARE CONTROL
CLASSIFICATION
Definition
CO
Cutoff
SCO
Semi-Cutoff
Medium control of light
above 80 Vertical
NCO
Non-Cutoff
No control requirements
above 80 Vertical
FCO
Full-Cutoff
Strict control of light above
80 Vertical
Zero emission above 90 Vertical
Product Guide
Normally Used for:
Spacings up to 4 times
the mounting height
Normally Used for:
TYPE III
TYPE IV
Strict control of light
above 80 Vertical
2.5% emission above 90 Vertical
TYPE V
Applications & Design
Floodlighting
A P P L I C AT I O N S
IES Classifications
Setback
The IES beam spreads indicate the angular
ranges (horizontally and vertically) through
which the intensity of the floodlight is
greater than 10% of its maximum intensity.
This angular range is referred to as the
'Field Angle'.
For example:
Asymmetrical beam spread
138° (H) x 119° (V)
HORIZONTAL
The recommended setback is three-fourth
the building height. If a building is 30 feet tall,
the recommended setback is 22.5 feet from
the building. Locating the floodlight closer to
the building will sacrifice uniformity; setting
it farther back will result in a loss of
efficiency.
Setback distance = 3/4 x building height
3/4 (30 ft.) = 22.5 ft.
Setback
IES Beamspread Classification
IES
Type
10° up to 18°
18° up to 29°
29° up to 46°
46° up to 70°
70° up to 100°
100° up to 130°
130° and up
1
2
3
4
5
6
7
Sign Lighting
Considerations:
1. Setback
2. Spacing
3. Aiming
VERTICAL
= IES 7 X 6
Field
Angle
Degrees
Sign Lighting
When lighting a sign with ground-mounted
floodlights, there are three considerations:
setback, spacing and aiming.
Beam
Description
very narrow
narrow
medium narrow
medium
medium wide
wide
very wide
Spacing
The rule of thumb for spacing floodlights is
not to exceed two times the setback
distance. If the setback is 22.5 feet, the
floodlights should not be placed more than
45 feet apart.
When using ground-mounted floodlights to
light a sign, the recommended setback is a
distance equal to three-fourths the sign
height. For example, the setback distance for
a 12-foot by 6-foot sign would be 4.5 feet.
Locating the floodlight closer will sacrifice
uniformity while setting it farther back will
result in a loss of efficiency.
Setback distance = 3/4 x sign height
3/4 (6 ft.) = 4.5 ft.
Spacing = 2 x setback distance
22.5 ft. x 2 = 45 ft. apart
The IES classification was formerly referred
to as NEMA Type.
The following outdoor design tips provide
general guidelines for lighting design. These
guidelines may not apply to all applications.
Spacing
GROUND-MOUNTED FLOODLIGHTS
Ground-mounted floodlights are used to light
building facades, signs and flagpoles.
Facade Lighting
When lighting building facades with groundmounted floodlights, three factors are
considered: setback, spacing and aiming.
Facade Lighting
Considerations:
1. Setback
2. Spacing
3. Aiming
Aiming
The floodlight should be aimed at least twothirds the height of the building. For example,
if a building is 30 feet high, the
recommended aiming point is approximately
20 feet high. After installation is complete,
aiming can be adjusted to produce the best
appearance. Mounting a full or upper visor
to the floodlight can reduce unwanted spill
light.
The rule of thumb for spacing floodlights is
not to exceed two times the setback
distance. If the setback is 4.5 feet, the
floodlights should not be placed more than 9
feet apart.
Spacing = 2 x setback distance
4.5 ft. x 2 = 9 ft. apart
Aiming point = 2/3 x building height
2/3 (30 ft.) = 20 ft. high
Product Guide
275
Applications & Design
Floodlighting
L O C AT I O N / A I M I N G
G U I D E L I N E S
Spacing
Spacing
Ideally, three floodlights are recommended
to light a flag. The floodlights should be
placed approximately 120° apart.
When more than one pole is added, pole
placement is a concern. The "4 times" rule of
thumb for spacing indicates that a pole
should be placed four times the mounting
height from the adjacent poles. If a flood is
mounted on a 20-foot pole, space the poles
80 feet apart.
Aiming
The floodlight should be aimed at least twothirds up the sign. For example, if a sign is
six feet tall, then the floodlight will be aimed
approximately four feet high. After
installation is completed, aiming can be
adjusted to produce the best appearance.
Mounting a full or upper visor to the
floodlight can reduce unwanted glare.
3 floodlights spaced 120° apart
Pole spacing = 4 x mounting height
4 (20-ft. pole) = 80 feet between poles
Aiming point = 2/3 x sign height
2/3 (6 ft.) = 4 ft. high
80'
40'
Aiming
The recommended aiming point for each
floodlight is the center of the flag or the top
of the pole. Mounting a full or upper visor to
the floodlight can reduce unwanted spill
light.
Flag Lighting
Ground-mounted floodlights also can be
used to light flags. Setback, spacing and
aiming must all be considered.
Setback
The recommended setback for lighting a
flag is one-third times the pole height. If the
pole is 30 feet tall, the floodlight should be
set back a distance of 10 feet away from the
pole.
80'
160'
120°
Flag Lighting
Considerations:
1. Setback
2. Spacing
3. Aiming
40'
120°
120°
20'
Vertical Aiming
A single floodlight uses the two-thirds rule of
thumb for vertical aiming. The fixture is
aimed 2/3 of the distance across the area to
be lighted and at least 30° below horizontal.
If the area to be lighted is 40 feet across, the
recommended aiming point is 27 feet.
Aiming point = 2/3 across distance to be lighted
2/3 (40 ft.) = 27 ft. aiming point
aim at least 30˚ to avoid glare
POLE-MOUNTED FLOODLIGHTS
General Area Lighting
Pole-mounted floodlights commonly are
used for general area lighting applications
such as parking lots and storage yards.
Mounting height, spacing, vertical aiming
and horizontal aiming should be considered.
General Lighting
Considerations:
1. Mtg. Height
2. Spacing
3. Vertical aiming
4. Horizontal aiming
Setback distance = 1/3 x pole height
1/3 (30 ft.) = 10 ft.
27'
13'
40'
Additionally, to minimize glare, the
recommended aiming point distance should
never exceed twice the mounting height. If a
pole is 20 feet high, the vertical aiming point
should not exceed 40 feet out.
2 (20 ft. mounting height) = 40 ft.
Horizontal Aiming
Mounting Height
Mounting height = 1/2 distance to be lighted
1/2 (40 ft.) = 20 ft.
GL
IN
AIM
20'
276
Product Guide
INE
AIM
IN
G
10'
The recommended mounting height is one
half the distance across the area to be
lighted. If the area to be lighted is 40 feet
across, the lowest recommended mounting
height is 20 feet.
LIN
E
30'
When an additional floodlight is added to a
single pole, horizontal aiming also must be
considered. First, each floodlight should be
vertically aimed according to the two-thirds
rule. As long as the floodlight has a horizontal
NEMA 6 or 7 beamspread, the floodlights can
be aimed up to 90° apart.
90˚
40'
AIMING POINT
Applications & Design
Roadway Lighting
C A L C U L AT I O N S
American Electric Lighting offers an extensive line of luminaires for your roadway lighting applications. The calculations which follow will help
you determine the type, quantity and placement of these luminaires. Refer to the data provided in the INTRODUCTION to the APPLICATIONS &
DESIGN section of this catalog. You also will need data from the Photometric Test Report for the luminaire(s) being considered. Contact your
American Electric Lighting representative for these reports. A sample report is provided for your use in the following calculations.
Calculations
Initial Lamp
Coefficient of
Light Loss
Lumens
x Utilization
x Factor
Average
Maintained =
Footcandles
Pole
Spacing
Pole Spacing x Road Width
Initial Lamp
Coefficient of
Light Loss
Lumens
x Utilization
x Factor
=
Average Maintained
Footcandles x
Initial
Lamp
Lumens
Averaged Maintained
Footcandles
=
Coefficient
Utilization
Pole
Spacing
x
x
Road
Width
x
Road
Width
Light Loss
Factor
SAMPLE CALCULATIONS
A roadway is to be lighted to a level of 1fc (Average Maintained Footcandles). The roadway is 45 feet wide and the poles are 30 feet high, therefore, the mounting
height ratio is 1.5
The Photometric Test Report provides: Initial Lamp Lumens = 14,000. Coefficient of Utilization (at 1.5MHR) = 43% for the 175W MH lamp used in an American Electric
Lighting LuxMaster® luminaire.
The light loss factor provided in the preceding charts for the 175W MH lamp is 0.70. Initial lamp lumens also are provided in this chart.
Pole Spacing =
14,000 (ILL) x .43 (CU) x .70 (LLF)
= 94 Feet (PS)
1 (AMF) x 45 (RW)
If pole spacing is known, then average maintained footcandles can be calculated:
Average Maintained Footcandles =
14,000 (ILL) x .43 (CU) x .70 (LLF)
= .996 (AMF)
94 (PS) x 45 (RW)
Or initial lamp lumens can be calculated:
Initial Lamp Lumens =
1 (AMF) x 94 (PS) x 45 (RW)
= 14,000 (ILL)
.43 (CU) x .70 (LLF)
Other application data may be determined by similar calculations. Contact your local American Electric Lighting representative for assistance.
AMF - Average Maintained Footcandles
CU - Coefficient of Utilization
ILL - Initial Lamp Lumens
MHR - Mounting Height Ratio
LLF - Light Loss Factor
PS - Pole Spacing
RW - Road Width
Product Guide
277
TERMS AND CONDITIONS OF SALE
For Shipments Within the United States*
Effective February 1, 2006
TERMS:
All American Electric Lighting products — 1% cash discount will be
allowed on invoices paid by the 10th of the month following the month of
billing. Payments made after the 10th are due on a net basis to the 25th
(1% 10th prox, net 25th prox).
FREIGHT ALLOWANCE:
Products from American Electric Lighting may be combined on an order
to qualify for freight allowance.
Shipments are F.O.B. our plants, Distribution Centers or Field
Warehouses:
●
●
All factory orders having a distributor price of
$2,000 or more for one consignee for one release
qualify for freight allowed.
Warehouse orders of stock items having a
distributor price of $2,000 or more for one
consignee for one release qualify for freight allowed.
●
All orders having a distributor price of less than
$2,000 will be assessed freight and handling charges.
●
Anchor bolts are included with American Electric
Lighting poles. Pre-shipped anchor bolts having a
distributor price of less than $2,000 will be assessed
freight and handling charges.
ALL SHIPMENTS — On orders qualifying for freight allowance, we
reserve the right to route at our discretion. We will ship in the manner
selected by the customer provided the customer assumes any additional
transportation costs.
TRANSPORTATION CLAIMS:
Our equipment is tested for mechanical defects prior to shipping. Our
packaging is regularly inspected by transportation authorities who
assume responsibility for both apparent and concealed damages
sustained by improper handling. Title passes to purchaser upon delivery
by us to the carrier, and all claims for damages or shortages in transit
shall be made by purchaser with delivering carrier. We shall be glad to
assist when called upon provided notification is given in writing within
15 days of receipt of shipment.
PACKAGING:
The company reserves the right to alter the quantities of any order so as
to conform to standard packaging.
PRICES:
Prices are subject to change without notice. In the event of price
increases, all orders on hand will be filled at lower prices provided such
orders are released for shipping prior to the price increase. If the orders
are not released for shipment prior to the price increase, the orders will
be billed at prices in effect at the time of shipment. Special quoted
orders which cannot be released for shipping prior to the price increase
may be subject to an increase in price. Minimum billing is $100 net.
Prices do not include lamps unless so specified. Orders for parts totaling
less than $15 will be billed $15 lump sum.
278
designated on the return authorization. Credit will be issued based on the
original invoice price, or price in effect at time of return, whichever is
lower, less a restocking charge of 25% minimum (to partially defray our
cost of handling), less reconditioning and replacing costs if necessary,
and less the freight expense of the original shipment. The reconditioning
charge will be determined by the repair, refinishing or reconditioning
required to restore the merchandise to a saleable condition. All nonstocking, special, custom-made or outdated, and modified versions of
normal factory stocking items are not returnable. Authorization will not
be granted when value of all items to be returned is less than $100.
Return from any one job will be limited to not more than 10% of the total
job value.
SERVICE AREA LIMITATION:
The company reserves the right to refuse to make quotations, accept
orders or make shipments to points of destination outside of the regular
or assigned selling and service area of the distributor.
GUARANTEE:
American Electric Lighting warrants all equipment to be free from defect
in manufacturing, under normal and proper storage, installation, and use,
for a period of one (1) year. In addition we provide a Six (6) year
warranty on the factory installed electrical system (consisting of ballast,
ignitor, capacitor, lamp socket, terminal board, PEC receptacle, and
wiring) inside AEL products. Our guarantee liability extends only to the
repair or replacement of the defective part and no labor charges for
correction of the defect by repair or replacement will be honored by
American Electric Lighting unless prior written authority has been
granted by our Customer Service Department.
CANCELLATION CHARGE:
Orders for stocking items may be cancelled prior to shipping without
charge. All other orders may not be cancelled unless we are reimbursed
for work already performed and for special material purchased by our
company. If an order is cancelled after shipment or if delivery is refused
at destination, all warehousing, delivery and return costs will be charged
to the customer.
GENERAL:
Possession of a price sheet does not entitle one to purchase.
Specifications are subject to change without notice. Consult factory for
verification. The compliance of our product to individual project
specifications and the approval for their use is not warranted by our
company.
ACCEPTANCE:
Acceptance of orders can be made only at our plants, Distribution
Centers or Field Warehouses for warehouse orders on the basis of these
terms and conditions of sale. Acceptance of orders is limited to the
terms and conditions hereof. American Electric Lighting hereby objects
to additional or different terms offered by purchaser in its sales order or
any other document of purchaser. Such additional or different terms
shall not become a part of any order without the express written consent
of American Electric Lighting.
RETURN MERCHANDISE:
American Electric Lighting reserves the right to change these Terms and
Conditions of Sale without notice.
No merchandise may be returned without prior written authorization
from our factories. Requests to return merchandise must be made with
our agents for transmittal to the factory within four (4) months from date
of shipment by us. All returns must be shipped prepaid to the location
* For shipments outside the United States, contact factory for applicable
Terms and Conditions of Sale.
Product Guide
TERMS AND CONDITIONS OF SALE
For Shipments Within Canada*
Effective September 1, 2004
TERMS:
DROP SHIPMENTS:
All American Electric Lighting Canada products payment terms are 2%10 or Net 30 days. 2%-10 days means that: All invoices dated from the
first to the 15th of the month are payable on the 25th of the same month.
All invoices from the 15th to the 30th of the month are payable on the
10th of the following month. Alternatively, all invoices are due Net 30
days following invoice date.
The company reserves the right to refuse to make direct shipments to
points of destination outside of the regular or assigned selling and
service area of the distributor.
FREIGHT ALLOWANCE:
Shipments are F.O.B. our plants, Lachine, Quebec, and St. Hyacinthe,
Quebec, and our Canadian Field Warehouses. Warehouse or Factory
orders must equal $2,000.00 DSP or more for shipment to one consignee
for one release to qualify for freight allowance. All orders having a
distributor price of less than $2,000.00 will be assessed freight and
handling charges. Special customer shipping requirements that cause
additional shipping expenses above normal may be charged for the
additional cost.
TRANSPORTATION CLAIMS:
Our equipment is tested for malfunctions and defects prior to shipping.
Our packaging is regularly inspected by transportation authorities who
assume responsibility for both apparent and concealed damages
sustained by improper handling. Title passes to purchaser upon delivery
by us to carrier, and all claims for damages or shortages in transit shall
be made by purchaser with delivering carrier. We shall be glad to assist
when called upon, provided notification is given in writing within 15 days
of receipt of shipment.
GUARANTEE:
American Electric Lighting warrants all equipment to be free from defect
in manufacturing, under normal and proper storage, installation, and use,
for a period of one (1) year. In addition we provide a Six (6) year
warranty on the factory installed electrical system (consisting of ballast,
ignitor, capacitor, lamp socket, terminal board, PEC receptacle, and
wiring) inside AEL products. Our guarantee liability extends only to the
repair or replacement of the defective part and no labor charges for
correction of the defect by repair or replacement will be honored by
American Electric Lighting unless prior written authority has been
granted by our Customer Service Department.
CANCELLATION CHARGES:
Orders for stocking items may be cancelled prior to shipping without
charge. All other orders may not be cancelled unless we are reimbursed
for work already performed and for special material purchased by our
company. If an order is cancelled after shipment or if delivery is refused
at destination, all warehousing, delivery, and return costs will be
charged to the customer.
GENERAL:
The company reserves the right to alter quantities of any order so as to
conform to standard packaging, except for job site requirements.
Possession of a price sheet does not entitle one to purchase.
Specifications are subject to change without notice. Consult factory for
verification. The compliance of our product to individual project
specifications and the approval for their use is not warranted by our
company.
PRICES:
ACCEPTANCE:
Prices are subject to change without notice. In the event of price
increases, all orders on hand will be filled at lower prices provided such
orders are released from shipping prior to the price increase. If the
orders are not released for shipment prior to the price increase, the
orders will be billed at prices in effect at the time of the shipment.
Minimum billing is $100 net. Prices do not include lamps unless so
specified. Prices exclude all taxes. Orders for parts totaling less than $50
will automatically be billed $50.
Acceptance of orders can only be made at our plant as noted in the
FREIGHT ALLOWANCE section or at Field Warehouses for warehouse
orders on the basis of the terms and conditions of sale printed on our
current distributor price sheet, acknowledgments and invoices.
PACKAGING:
RETURN MERCHANDISE:
American Electric Lighting Canada reserves the right to change these
Terms and Conditions of Sale without notice.
* For shipments outside Canada, contact factory for applicable Terms
and Conditions of Sale.
No merchandise may be returned without prior written authorization
from our factories. Requests to return merchandise must be made with
our agents for transmittal to the factory within four (4) months from date
of shipment by us. All returns must be shipped prepaid to the location
designated on the return authorization. Credit will be issued based on
the original invoice price, or price in effect at time of return, whichever
is lower, less a restocking charge of 25% minimum (to partially defray
our cost of handling), less reconditioning and replacing costs if
necessary, and less the freight expense of the original shipment. The
reconditioning charge will be determined by the repair, refinishing or
reconditioning required to restore the merchandise to a saleable
condition. All non-stocking, special, custom-made or outdated, and
modified versions of normal factory stocking items are not returnable.
Authorization will be granted on $100 minimum value only.
Product Guide
279
Index
315 Series ...........................................................................140
Floodlighting Accessories................................................192
Floodlighting Ballast Matrices.........................................197
Aluminum Pole Mounting Brackets ...............................229
AMAC / SMAC ....................................................................252
AMAW / SMAW .................................................................250
American Revolution Series 247........................................86
American Revolution Cutoff Series 247............................88
AmeriSport™ Series ASP ................................................188
ANSI Color Chart................................................................212
Area Accessories ..............................................................172
Area Ballast Matrices .......................................................176
AVL .......................................................................................158
Bainbridge Series 870 ........................................................96
Ballast Matrices
Roadway ........................................................................54
Decorative Post Top ...................................................132
Security ........................................................................155
Area ..............................................................................176
Floodlighting ................................................................197
Compact Flood Series 51..................................................180
Contempo Series 245 ..........................................................90
D Series...............................................................................204
D779 Series .........................................................................210
DA Series.............................................................................209
DB Series.............................................................................208
DBE Series ..........................................................................207
DD Series.............................................................................201
DE Series .............................................................................200
Decorative Post Top Ballast Matrices............................132
DP Series.............................................................................203
DPN Series..........................................................................202
DuraStar™ Series 20 ...........................................................10
DuraStar™ Series 30 ...........................................................12
Dusk To Dawn Series DTD................................................150
DUX Series ..........................................................................206
DX Series.............................................................................205
280
Product Guide
Georgian Series GRP ..........................................................98
Heavy-Duty Wallpack 882 ..................................................48
Heritage Collection ..............................................................62
Cresthill Classic ............................................................66
Cresthill Sphere ............................................................68
Branson ..........................................................................82
Cresthill Centennial ......................................................70
Cresthill Glass ...............................................................72
Depot ..............................................................................84
Lexington........................................................................74
Marietta Series .............................................................62
Sumter Series................................................................64
Syracuse Series............................................................76
Victorian Series.............................................................78
Yorktown.........................................................................80
Heritage Poles ....................................................................100
Accessories.................................................................108
Chadsworth Series.....................................................100
New Albany Series.....................................................102
Statesboro Series.......................................................104
Waycross Series.........................................................106
InterState II
775...................................................................36
LPS Roadway - SP2.............................................................42
LPS Roadway - SRP.............................................................38
LPS Roadway - SRX.............................................................40
LuxMaster® Classic Series LL ........................................168
LuxMaster® Classic Series LM ......................................166
LuxMaster® Classic Series LS........................................164
LuxMaster® LPS Luminaire Series LML........................170
LuxMaster® Luminaire Series 153 .................................162
LuxMaster® Luminaire Series 53 ...................................160
Multi-Mount™ 285 ..............................................................34
Index
NEMA Head 11...................................................................142
Security Accessories .......................................................154
NEMA Head Package Series 11 PKG .............................144
Security Ballast Matrices.................................................155
Series 11 "L" Package ........................................................146
Series 110 ............................................................................148
Series 165 ............................................................................152
Shorting Caps .....................................................................211
SignLite 875 ...........................................................................50
SMAWL................................................................................254
Sportslighting Series SPF ................................................190
SPRTC ..................................................................................237
SPRTS ..................................................................................241
SSA.......................................................................................221
SSAH ....................................................................................222
SSF .......................................................................................233
SSS .......................................................................................225
STC .......................................................................................236
Steel Pole Mounting Brackets.........................................230
STS .......................................................................................226
STSH.....................................................................................227
Photocontrol Accessories ...............................................212
Photocontrol Recommendation Chart ............................212
Pole Options & Accessories ....................................228, 256
Pole Technical Data
Florida Wind Rating....................................................216
General Information ...................................................217
Illustrated Samples ....................................................214
Wind Map ....................................................................215
Quartz Flood Series 570....................................................186
Residential Post Top Series RES.......................................92
Roadway 115 ........................................................................14
Roadway 115 Cutoff .............................................................16
Roadway 125 ........................................................................22
Roadway 125 Cutoff .............................................................24
Roadway 315 ........................................................................18
Roadway 315 Cutoff .............................................................20
Roadway 325 ........................................................................26
Roadway 325 Cutoff .............................................................28
Roadway 327.........................................................................30
Roadway 413.........................................................................32
Roadway Accessories ........................................................52
Roadway Ballast Matrices .................................................54
RSA.......................................................................................218
RSAH ....................................................................................220
RSS .......................................................................................223
RTA .......................................................................................219
RTAU.....................................................................................244
RTCD.....................................................................................234
RTCDDB ...............................................................................235
RTF .......................................................................................231
RTFDB ..................................................................................232
RTS .......................................................................................224
RTSU.....................................................................................248
Technical Data
Calculations .................................................................277
Floodlighting Aiming...................................................276
Flood Lights - Applications........................................275
Fuse Ratings ................................................................268
HPS Replacement Starters .......................................266
Lamp Selection ...........................................................267
Location/Aiming Guidelines......................................276
Luminaire Classification Systems............................274
Terms & Conditions............................................................278
TwistPack™ Series TWT ....................................................94
UltraFlood™ Series 75 .....................................................182
UltraFlood™ Series 77.......................................................184
Underpass 581/681...............................................................46
Underpass GST.....................................................................44
Product Guide
281
NOTES
NOTES
NOTES
NOTES
NOTES
NOTES
Download