American Electric Lighting Product Guide Edition Two We are pleased to present the second edition of the American Electric Lighting and Dark to Light product guide. AEL is a company on the move in the pubic infrastructure market, with products that have been successful for over 50 years in roadway, security, area, flood and decorative lighting. DTL has been a large part of that success by offering top-of-the-line photocontrols. Our goal is to continue to provide the superior design, quality and reliability that our customers demand. As you review the new guide, be sure to look for the NEW designation on products throughout the catalog. We have added over 70 pages of information to the Decorative Post Tops section, including an extensive expansion of the Heritage family. Also new in this edition are ballast and optical performance matrices at the end of each product section. Use them to help determine the best ballast and optical configurations for your needs. Also, a selection guide has been added to the DTL pages to help you choose the best photocontrols for your application. In addition, you will also find a Frequently Ordered Products section near the end of the guide. For the most up-to-date product information, photometric files, specification sheets and other technical data that AEL and DTL have to offer, visit our website, www.americanelectriclighting.com. We at American Electric Lighting are confident this catalog will be a useful tool for you. We look forward to working with you to satisfy your lighting requirements. Thank you for your continued support. Sincerely, The AEL Team American Electric Lighting™ Roadway Lighting TA B L E O F C O N T E N T S ROADWAY LIGHTING 2 DuraStar™ Roadway Lighting System Series 20 Product Overview ...............................10 Ordering Information ..........................11 Roadway Cobrahead Series 325 Product Overview ...............................26 Ordering Information ..........................27 DuraStar™ Roadway Lighting System Series 30 Product Overview ...............................12 Ordering Information ..........................13 Roadway Cutoff Cobrahead Series 325 Product Overview ...............................28 Ordering Information ..........................29 Roadway Cobrahead Series 115 Product Overview ...............................14 Ordering Information ..........................15 Roadway Cobrahead Series 327 Product Overview ...............................30 Ordering Information ..........................31 Roadway Cutoff Cobrahead Series 115 Product Overview ...............................16 Ordering Information ..........................17 Roadway Cobrahead Series 413 Product Overview ...............................32 Ordering Information ..........................33 Roadway Cobrahead Series 315 Product Overview ...............................18 Ordering Information ..........................19 Multi-Mount™ Series 285 Product Overview ...............................34 Ordering Information ..........................35 Roadway Cutoff Cobrahead Series 315 Product Overview ...............................20 Ordering Information ..........................21 InterState™ II Luminaire Series 775 Product Overview ...............................36 Ordering Information ..........................37 Roadway Cobrahead Series 125 Product Overview ...............................22 Ordering Information ..........................23 LPS Roadway/Area Luminaire Series SRP Product Overview ...............................38 Ordering Information ..........................39 Roadway Cutoff Cobrahead Series 125 Product Overview ...............................24 Ordering Information ..........................25 LPS Roadway/Area Luminaire Series SRX Product Overview ...............................40 Ordering Information ..........................41 Product Guide American Electric Lighting™ Roadway Lighting, Decorative Post Top Lighting TA B L E O F C O N T E N T S LPS Roadway/Area Luminaire Series SP2 Product Overview ...............................42 Ordering Information ..........................43 Cresthill Classic Underpass Series GST Product Overview ...............................44 Ordering Information ..........................45 Cresthill Sphere Underpass Series 581/681 Product Overview ...............................46 Ordering Information ..........................47 Cresthill Centennial Product Overview................................70 Ordering Information ..........................71 Wall Pack 882 Cresthill Glass Product Overview................................66 Ordering Information ..........................67 Product Overview................................68 Ordering Information ..........................69 Product Overview ...............................48 Ordering Information ..........................49 Product Overview................................72 Ordering Information ..........................73 Signlite Series 875 Product Overview ...............................50 Ordering Information ..........................51 Lexington Accessories..........................................................................52 Heritage Collection Syracuse Series Product Overview................................76 Ordering Information ..........................77 Ballast Matrices ..................................................................54 DECORATIVE AND POST-TOP LIGHTING Heritage Collection Product Overview................................74 Ordering Information ..........................75 Victorian Series Product Overview................................78 Ordering Information ..........................79 Marietta Series Product Overview ...............................62 Ordering Information ..........................63 Yorktown Sumter Series Product Overview ...............................64 Ordering Information ..........................65 Product Overview................................80 Ordering Information ..........................81 Product Guide 3 American Electric Lighting™ Decorative Post Top Lighting TA B L E O F C O N T E N T S Heritage Collection Branson Product Overview................................82 Ordering Information ..........................83 Bainbridge Series Product Overview................................96 Ordering Information ..........................97 Georgian Series Depot Product Overview................................98 Ordering Information ..........................99 Product Overview................................84 Ordering Information ..........................85 Heritage Series American Revolution Series 247 Product Overview................................86 Ordering Information ..........................87 American Revolution Series 247 Product Overview................................88 Ordering Information ..........................89 Contemporary Series 245 Product Overview................................90 Ordering Information ..........................91 Chadsworth Series Product Overview..............................100 Ordering Information ........................101 New Albany Series Product Overview..............................102 Ordering Information ........................103 Statesboro Series Product Overview..............................104 Ordering Information ........................105 Waycross Series Product Overview..............................106 Ordering Information ........................107 Weatherproof Receptacles ..........................................108 Residential Series RES Product Overview................................92 Ordering Information ..........................93 TwistPack Series TWT Product Overview................................94 Ordering Information ..........................95 Banner Arms Product Overview..............................110 Ordering Information ........................111 Flagpole Holders Product Overview..............................112 Ordering Information ........................113 Street Signs, Octagonal Frames Product Overview..............................114 Ordering Information ........................115 Street Signs, Oval Frames Product Overview..............................116 Ordering Information ........................117 4 Product Guide American Electric Lighting™ Decorative Post Top, Security Lighting, Area Lighting TA B L E O F C O N T E N T S Heritage Series Street Signs, Rectangular Frames Product Overview..........................118 Ordering Information.....................119 Series 11 “L” Package Product Overview..............................146 Ordering Information ........................147 Street Signs, Curved Frames Product Overview..........................120 Ordering Information.....................121 Series 110 Product Overview..............................148 Ordering Information ........................149 Ladder Rests ....................................................................122 Post Top Finials................................................................123 WTA Series Cross Arms and Wall Brackets Product Overview..........................126 Ordering Information.....................126 Diagrams.........................................127 OS Series Cross Arms and Wall Brackets Product Overview..........................128 Ordering Information.....................128 Diagrams.........................................129 Dusk to Dawn Series DTD Product Overview..............................150 Ordering Information ........................151 Series 165 Product Overview..............................152 Ordering Information ........................153 Orientation Guide ............................................................130 Ballast Matrices ..............................................................132 Accessories ........................................................................154 Ballast Matrices .................................................................155 SECURITY LIGHTING 315 Series Product Overview..........................140 Ordering Information.....................141 AREA LIGHTING AVL Product Overview..............................158 Ordering Information ........................159 NEMA Head 11 Product Overview..........................142 Ordering Information.....................143 NEMA Head Package Series 11 PKG Product Overview..........................144 Ordering Information.....................145 LuxMaster® Luminaire 53 Product Overview..............................160 Ordering Information ........................161 LuxMaster® Luminaire 153 Product Overview..............................162 Ordering Information ........................163 Product Guide 5 American Electric Lighting™ Area Lighting, Floodlighting, Photocontrols TA B L E O F C O N T E N T S LuxMaster® Classic Series LS Product Overview .............................164 Ordering Information ........................165 Quartz Flood Series 570 Product Overview .............................186 Ordering Information ........................186 LuxMaster® Classic Series LM Product Overview .............................166 Ordering Information ........................167 Quartz Flood Series 474 Product Overview .............................187 Ordering Information ........................187 LuxMaster® Classic Series LL Product Overview .............................168 Ordering Information ........................169 AmeriSport Series ASP Product Overview .............................188 Ordering Information ........................189 LuxMaster® Luminaire Series LML Product Overview .............................170 Ordering Information ........................171 Sportslighting Series SPF Product Overview .............................190 Ordering Information ........................191 Accessories.......................................................................172 Accessories .........................................................................192 Ballast Matrices ...............................................................176 Ballast Matrices ..................................................................197 FLOODLIGHTING Compact Flood Series 51 Product Overview .............................180 Ordering Information ........................181 ELECTRONIC PHOTOCONTROLS DE Series Silicon Product Overview .............................200 Ordering Information ........................200 DD Series Classic UltraFloodTM Series 75 Product Overview .............................182 Ordering Information ........................183 Product Overview .............................201 Ordering Information ........................201 DPN Series UltraFloodTM Series 77 Product Overview .............................184 Ordering Information ........................185 Ordering Information ........................133 6 Product Guide Product Overview .............................202 Ordering Information ........................202 American Electric Lighting™ Photocontrols, Poles, Options & Accessories TA B L E O F C O N T E N T S DP Series Filtered Silicon Product Overview..........................203 Ordering Information.....................203 Shorting Cap D Series Classic Accessories & Special Controls ...........................................212 Product Overview..................................211 Ordering Information ............................211 Product Overview..........................204 Ordering Information.....................204 POLES ® DX Series Part Night Product Overview..........................205 Ordering Information.....................205 DUX Series Basic Product Overview..........................206 Ordering Information.....................206 DBE Series Button Product Overview..........................207 Ordering Information.....................207 DB Series Button Product Overview..........................208 Ordering Information.....................208 DA Series Button Product Overview..........................209 Ordering Information.....................209 D779 Series Product Overview..........................210 Ordering Information.....................210 RSA ...................................................................................218 RTA ...................................................................................219 RSAH .................................................................................220 SSA ...................................................................................221 SSAH .................................................................................222 RSS ...................................................................................223 RTS ...................................................................................224 SSS ...................................................................................225 STS ...................................................................................226 STSH..................................................................................227 Pole Options .....................................................................228 Aluminum Mounting Brackets ......................................229 Steel Mounting Brackets...............................................230 RTF ...................................................................................231 RTFDB ...............................................................................232 SSF ...................................................................................233 RTCD..................................................................................234 RTCDDB ............................................................................235 STC ...................................................................................236 SPRTC ...............................................................................237 SPRTS ...............................................................................241 RTAU..................................................................................244 RTSU..................................................................................248 AMAW / SMAW...............................................................250 AMAC / SMAC .................................................................252 SMAWL.............................................................................254 Options & Accessories ..................................................256 OPTIONS & ACCESSORIES HPS Replacement Starters............................................266 Lamp Selection ................................................................267 Fuse Ratings.....................................................................268 Luminaire Classification Systems. ...............................274 Floodlighting Applications. ............................................275 Floodlight Calculations ...................................................276 Roadway Lighting Application Design.........................277 Terms & Conditions.........................................................278 Index..................................................................................280 Product Guide 7 8 Product Guide ROADWAY LIGHTING DuraStar™ Series 20 ...............................................10 DuraStar™ Series 30 ...............................................12 Roadway 115 ............................................................14 Roadway 115 Cutoff .................................................16 Roadway 315 ............................................................18 Roadway 315 Cutoff .................................................20 Roadway 125 ............................................................22 Roadway 125 Cutoff .................................................24 Roadway 325 ............................................................26 Roadway 325 Cutoff .................................................28 Roadway 327 .............................................................30 Roadway 413 .............................................................32 Multi-Mount™ 285....................................................34 InterState™ II 775....................................................36 LPS Roadway - SRP .................................................38 LPS Roadway - SRX .................................................40 LPS Roadway - SP2..................................................42 Underpass GST.........................................................44 Underpass 581/681 ...................................................46 Heavy-Duty Wallpack 882.......................................48 Signlite 875 ................................................................50 Accessories ..............................................................52 Ballast Matrices .......................................................54 American Electric Lighting™ DuraStar™ Series 20 Roadway Lighting System 35-150W HPS, 100-175W MV/MH P R O D U C T O V E R V I E W Features: Revolutionary DuraLock™ docking system provides modular installation and interchangeability for easy maintenance. Rugged die-cast, powder-coated docking station mounts securely to mast-arm to ensure secure wiring and long-lasting stability. Durable lightweight lighting fixture positively docks by plugging in with a 20° locking twist. High-efficiency optical system maximizes light output while minimizing glare. Starter component is externally accessible for easy maintenance and is fully encapsulated for long life. Star Friendly™ cutoff distribution patterns available. Wildlife shield is cast into the docking station (not a separate piece) and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms. Cam-latch door frame allows easy re-lamping without tools. Optional (BZ) finish shown Large surface area "breathing seal" gasket, seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture. Applications: Roadways Residential areas Coastal areas — salt/corrosive environments Parking lots Storage areas Photocontrol receptacle is adjustable without tools. All electrical components warranted by American Electric Lighting's 6-year guarantee. E39 mogul base socket standard. Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS Optical chamber is IP64 rated standard. Complies with ANSI: C136.2, C136.10, C136.15, C136.31 26 1/2'' (673) 9.2" (234) 12 1/2'' (318) 26.5" (673) 9'' (228) 12.5" (318) Vertical Tenon Mount 9.2" (234) Effective Projected Area (EPA) The EPA for the DuraStar™ is .56 sq. ft. The EPA for the DuraStar™ sag lens, is .70 sq. ft. Approx. Wt. = 14 lbs. 10 Product Guide 26.5" (673) For photometric information, visit our website, www.americanelectriclighting.com DuraStar™ Series 20 Roadway Lighting System 35-150W HPS, 100-175W MV/MH O R D E R I N G I N F O R M AT I O N Example: 2 0 1 0 S R N 1 2 0 R 3 F G L C P C Wattage / Source Series 20 DuraStar Cobrahead 03 05 07 10 15 17 35W 50W 70W 100W 150W 175W Voltage Distribution 120V 208V 220V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual Tap 120/240 wired 120V DT2 Dual Tap 120/240 wired 240V DT3 Dual Tap 240/480 wired 240V DT4 Dual Tap 240/480 wired 480V R2 Roadway Type II R3 Roadway Type III Ballast S HPS M MH V MV Refer to the ballast matrix on page 54 for compatibility. RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI MR Mag Reg (3 Coil) XX No Ballast 120 208 220 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 Options Refer to Optic Distribution Matrix below for compatibility Optics SA Sag Acrylic Lens SP Sag Polycarbonate Lens FG Flat Glass Clear Tempered Maximum number of options is six, for more options please contact your local American Electric Lighting representative Mounting (blank) DuraLock Docking Station set for 1-1/4” mast arm M2 2-bolt Internal 2” setting, for DuraLock Docking Station for 2” mast arm ML Less DuraLock Docking Station VT Vertical Tenon Docking Station Paint (blank) BZ Gray (standard) Bronze Starter3 (blank) Encapsulated plug-in4 SN No Ignitor (using self-igniting lamp) Misc. PC PK SS PL Listing UL CS UL Listed CSA Certified Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle NR No Photocontrol Receptacle1 PB Phosphor Bronze Contacts Lamp LC LD LG Lamp Included, Clear Lamp Included, Deluxe/Coated Self-Igniting Lamp2 5H NN SH LCU Notes: 1 2 3 4 5 Photocontrol Included per Voltage Specified Package (includes lamp, photocontrol, 5’ supply-wire, mast arm, hardware) Stainless Steel Fasteners (external) Distribution Pattern Indicator Label 50 Hertz Ballast Cycle5 No NEMA Label on Housing Shorting Cap Low Copper Alloy Content Docking Station (less than 1%) PB, PC, SH not available with NR option Requires SN option HPS only Externally mounted Limited availability, please contact your local American Electric Lighting representative Optic Distribution 03S 07S 10S 15S 17M 17V See pages 259-264 for a complete listing of Frequently Ordered Products R2SA ◆ ◆ ◆ - R3SA ◆ ◆ ◆ - R2SP ◆ ◆ ◆ ◆ ◆ ◆ R3SP ◆ ◆ ◆ ◆ ◆ ◆ R2FG ◆ ◆ ◆ ◆ - R3FG ◆ ◆ ◆ ◆ - Product Guide 11 DuraStar™ Series 30 Roadway Lighting System 200-400W HPS, 400W MV/MH P R O D U C T O V E R V I E W Features: Revolutionary DuraLock™ docking system provides modular installation and interchangeability for easy maintenance. Rugged die-cast, powder-coated docking station mounts securely to mast-arm to ensure secure wiring and long-lasting stability. Durable lightweight lighting fixture positively docks by plugging in with a 20° locking twist. High-efficiency optical system maximizes light output while minimizing objectionable glare. Star Friendly™ cutoff distribution patterns available. Starter component is externally accessible for easy maintenance and is fully encapsulated for long life. Wildlife shield is cast into the docking station (not a separate piece) and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms. Die-cast trigger latch on door frame enables easy and secure one-hand opening for re-lamping and maintenance. Large surface area "breathing seal" gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture. Applications: Roadways Residential streets Storage areas Parking lots Campuses Parks Photocontrol receptacle is adjustable without tools. All electrical components warranted by American Electric Lighting's 6-year guarantee. E39 mogul base socket standard. Suitable for -30°C MH & MV / -40°C HPS. Optical chamber is IP64 rated standard. DIMENSIONS Complies with ANSI: C136.2, C136.10, C136.15, C136.31 36 -1/4" (921) 36 -1/4 (921) 17-1/2" (445) 17-1/2" (445) 11" (279) 10" (254) Vertical Tenon Mount 36 -1/4" (921) Effective Projected Area (EPA) The EPA for the DuraStar™ Series 30 is 1.24 sq. ft. flat glass The EPA for the DuraStar™ Series 30 is 1.43 sq. ft. sag glass Approx. Wt. = 30 lbs. 12 Product Guide For photometric information, visit our website, www.americanelectriclighting.com DuraStar™ Series 30 Roadway Lighting System 200-400W HPS, 400W MV/MH O R D E R I N G I N F O R M AT I O N Example: 3 0 2 5 S C A M T 1 R 3 F G L C P C Wattage / Source Series 30 DuraStar Cobrahead 20 25 31 40 23 200W S HPS 250W M MH 310W V MV 400W 250/400W wired 250W 24 250/400W wired 400W Refer to the ballast matrix on page 54 for compatibility. Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI MR Mag Reg (3 Coil) XX No Ballast 120 208 220 240 277 347 480 MT1 MT2 MT7 TT1 TT7 TT3 DT1 120V 208V 220V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual Tap 120/240 wired 120V DT2 Dual Tap 120/240 wired 240V DT3 Dual Tap 240/480 wired 240V DT4 Dual Tap 240/480 wired 480V Distribution R2 Roadway Type II R3 Roadway Type III Refer to Optic Distribution Matrix below for compatibility Optics SG Sag Glass Clear Tempered FG Flat Glass Clear Tempered Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Mounting (blank) DuraLock Docking Station set for 1-1/4” mast arm M2 2-bolt Internal 2” setting, for DuraLock Docking Station ML Less DuraLock Docking Station VT Vertical Tenon Docking Station Color (blank) BZ Listing UL CS Gray (standard) Bronze UL Listed CSA Certified Lamp LC LD LG Starter3 (blank) Encapsulated Plug-In4 OB Open Board Internal SN No Ignitor (using self-igniting lamp) Misc. PC SS PL Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle NR No Photocontrol Receptacle1 PB Phosphor Bronze Contacts Notes: Lamp Included, Clear Lamp Included, Deluxe/Coated Self-Igniting Lamp2 5H NN SH LCU 1 2 3 4 5 PB, PC, SH not available with NR option Requires SN option Available in HPS only Externally mounted Limited availability, please contact your local American Electric Lighting representative Optic Distribution Photocontrol Included per Voltage Specified Stainless Steel Fasteners (external) Distribution Pattern Indicator Label 50 Hertz Ballast Cycle5 No NEMA Label on Housing Shorting Cap Low Copper Alloy Content Docking station (less than 1%) See pages 259-264 for a complete listing of Frequently Ordered Products 20S 25S 31S 40S 17M 25M 40M 17V 25V 40V R2SG R3SG R2FG R3FG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ Product Guide 13 Roadway Series 115 Roadway Lighting Luminaires — Cobrahead 35-400W HPS, 100-250W MV/MH P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance. Two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Optional four-bolt mounting provides extra security in high-vibration applications. Die-cast trigger latch on door frame enables easy and secure one-hand opening for re-lamping and maintenance. Large surface area "breathing seal" gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture. Wildlife shield is cast into the housing (not a separate piece) on the two-bolt unit and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms. Photocontrol receptacle is adjustable without tools. Anodized aluminum reflectors provide uniform lighting distribution with borosilicate glass, acrylic, or polycarbonate refractor. Applications: Roadways Residential streets Storage areas Parking lots Campuses Parks NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard. All electrical components warranted by American Electric Lighting's 6-year guarantee. E39 mogul base socket standard. Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17 10.1" (257) 27" (686) 10.1" (257) 13" (330) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 115 is 0.9 sq. ft. Approx. Wt. = 19 lbs. 14 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 115 Roadway Lighting Luminaires — Cobrahead 35-400W HPS, 100-250W MH/MV O R D E R I N G I N F O R M AT I O N Example: 1 1 5 1 5 S R N 1 2 0 R 2 D G L C P C Series 115 Single Door Cobrahead Ballast Wattage / Source 03 05 07 10 13 14 15 17 20 25 40 35W 50W 70W 100W 100/150W wired 100W 100/150W wired 150W 150W 175W 200W 250W 400W S M V HPS MH MV Refer to the ballast matrix on page 55 for compatibility. RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI MR Mag Reg (3 Coil) XX No Ballast Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Mounting (blank) 2-bolt Internal 1-1/4” setting (standard) EF External Fitter (2-bolt only) 4B 4-bolt Internal M2 2-bolt Internal 2” setting E2 External Fitter 2” Mast Arm (2-bolt only) Paint1 (blank) BK BZ WH UP Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 to L2 Position T3 3 Wire Operation (L1, N, L2 Position) Lamp LC LD LG UL Listed CSA Certified Fusing2 SF Single Fuse (120, 277, 347V) DF Double Fuse (208, 220, 240, 480V) BL SS CF PL 5H NN SH HK LCU BF Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle3 PB Phosphor Bronze Contacts 120V 208V 220V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual Tap 120/240 wired 120V DT2 Dual Tap 120/240 wired 240V DT3 Dual Tap 240/480 wired 240V DT4 Dual Tap 240/480 wired 480V R2 R3 RX Roadway Type II Roadway Type III Roadway Type II 4-way Refer to Optic Distribution Matrix below for compatibility Optics DA DP DG Drop Acrylic Prismatic Refractor Drop Polycarbonate Prismatic Refractor Drop Glass Prismatic Refractor Notes: Lamp Included, Clear Lamp Included, Deluxe/Coated Self-Igniting Lamp4 1 Open Board (standard) Encapsulated Plug-in Open Plug-in External Encapsulated Plug-in No Ignitor (using self-igniting lamp) 3 4 5 6 7 Misc. PC LA Listing UL CS 120 208 220 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 2 Starter5 (blank) EC OP ES SN Distribution Voltage Photocontrol Included per Voltage Specified Bubble Level Stainless Steel Fasteners (external) Charcoal Filter Distribution Pattern Indicator Label Lightning Arrestor (Void UL/CSA Certified Options) 50 Hertz Ballast Cycle6 No NEMA Label on Housing Shorting Cap Hinge Keeper Low Copper Alloy Content (less than 1%) Bridge Fitter7 Other colors available, please contact your local American Electric Lighting representative Voids UL/CSA Certified Options and not available in MT, TT, DT voltages PB, SH, and PC not available with NR option Requires SN option For HPS products only Limited availability, please contact your local American Electric Lighting representative Tested to withstand 3G vibration, 4B option required Optic Distribution 03S 05S 07S 10S 15S 20S 25S 40S 17M 25M 17V 25V See pages 259-264 for a complete listing of Frequently Ordered Products R2DA R3DA R2DP R3DP R2DG R3DG RXDG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ Product Guide 15 Roadway Series 115 Roadway Lighting Luminaires — Cutoff Style Cobrahead 35-250W HPS, 100-250W MV/MH P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance. Two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Optional four-bolt mounting provides extra security in high-vibration applications. Die-cast trigger latch on door frame enables easy and secure one-hand opening for re-lamping and maintenance. Star Friendly™ cutoff distribution patterns available. Large surface area "breathing seal" gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture. Wildlife shield is cast into the housing (not a separate piece) on the two-bolt unit and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms. Photocontrol receptacle is adjustable without tools. Anodized aluminum reflectors provide uniform lighting distribution with either flat or sag clear tempered glass. Applications: Roadways Residential streets Storage areas Parking lots Campuses Parks NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard. All electrical components warranted by American Electric Lighting's 6-year guarantee. E39 mogul base socket standard. Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17 Specs 27" (686) 6.5" (165) 13" (330) 13" (330) 6.5" (165) 8.3" (211) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 115 with cutoff is .74 sq. ft. Approx. Wt. = 19 lbs. 16 Product Guide 27" (686) 8.3" (211) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 115 with sag glass is .82 sq. ft. For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 115 Roadway Lighting Luminaires — Cutoff Style Cobrahead 35-250W HPS, 100-250W MH/MV O R D E R I N G I N F O R M AT I O N Example: 1 1 5 1 5 S C A M T 1 R 3 F G L C P C H P Wattage / Source Series 115 Single Door Cobrahead 03 05 07 10 13 14 15 17 20 25 35W 50W 70W 100W 100/150W wired 100W 100/150W wired 150W 150W 175W 200W 250W S M V HPS MH MV Refer to the ballast matrix on page 55 for compatibility. RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI MR Mag Reg (3 Coil) XX No Ballast Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Mounting (blank) 2-bolt Internal 1-1/4” setting (standard) EF External Fitter (2-bolt only) 4B 4-bolt Internal M2 2-bolt Internal 2” setting E2 External Fitter 2” Mast Arm (2-bolt only) Paint1 (blank) BK BZ WH UP Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Listing UL CS UL Listed CSA Certified Fusing2 SF Single Fuse (120, 277, 347V) DF Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle3 PB Phosphor Bronze Contacts Lamp LC LD LG Lamp Included, Clear Lamp Included, Deluxe/Coated Self-Igniting Lamp4 Starter5 (blank) EC OP ES SN Open Board (standard) Encapsulated Plug-in Open Plug-in External Encapsulated Plug-in No Ignitor (using self-igniting lamp) Misc. PC BL SS CF PL LA 5H NN SH HK HP LCU BF Voltage Ballast Distribution 120 208 220 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 120V 208V 220V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual Tap 120/240 wired 120V DT2 Dual Tap 120/240 wired 240V DT3 Dual Tap 240/480 wired 240V DT4 Dual Tap 240/480 wired 480V R2 R3 Roadway Type II Roadway Type III Refer to Optic Distribution Matrix below for compatibility Optics FG SG Flat Glass Clear Tempered Sag Glass Clear Tempered Notes: 1 2 3 4 5 6 7 8 Other colors available, please contact your local American Electric Lighting representative Voids UL/CSA Certified Options; not available in MT, TT, DT voltages PB, PC, and SH not available with NR option Requires SN option For HPS products only Limited availability, please contact your local American Electric Lighting representative FG optics only Tested to withstand 3G vibration, 4B option required Optic Distribution Photocontrol Included per Voltage Specified Bubble Level Stainless Steel Fasteners (external) Charcoal Filter Distribution Pattern Indicator Label Lightning Arrestor (Void UL/CSA Certified Options) 50 Hertz Ballast Cycle6 No NEMA Label on Housing Shorting Cap Hinge Keeper High Performance7 Low Copper Alloy Content (less than 1%) Bridge Fitter8 03S 05S 07S 10S 15S 20S 25S 17M 25M 17V 25V R2 SG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ R3 SG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ R2 FG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆1 ◆1 ◆1 ◆1 R3 FG ◆ ◆ ◆ ◆ ◆ ◆1 ◆1 ◆1 ◆1 R2 FG HP ◆ ◆ ◆ ◆ ◆ - R3 FG HP ◆ ◆ ◆ ◆ ◆ - Notes: 1 Use deluxe/coated lamp LD option See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 17 Roadway Series 315 Roadway Lighting Luminaires — Cobrahead with Power Door 35-400W HPS, 100-250W MV/MH P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance. Die-cast secondary Power Pad door places all electrical components on one easily interchangeable module with quick disconnects to main fixture housing. Two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Optional four-bolt mounting provides extra security in high-vibration applications. Die-cast trigger latch on lens frame enables easy and secure one-hand opening for re-lamping. Large surface area "breathing seal" gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture. Wildlife shield is cast into the housing (not a separate piece) on the two-bolt unit and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms. Photocontrol receptacle is adjustable without tools. Applications: Anodized aluminum reflectors provide uniform lighting distribution with borosilicate glass, acrylic or polycarbonate refractor. Roadways Residential streets Storage areas Parking lots Campuses Parks NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard. All electrical components warranted by American Electric Lighting's 6-year guarantee. E39 mogul base socket standard. Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31 10.1" (257) 27" (686) 10.1" (257) 13" (330) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 315 is 0.9 sq. ft. Approx. Wt. = 19 lbs. 18 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 315 Roadway Lighting Luminaires — Cobrahead with Power Door 35-400W HPS, 100-250W MV/MH O R D E R I N G I N F O R M AT I O N Example: 3 1 5 1 0 S M R D T 2 R 3 D G N R B L Wattage / Source Series 315 Power Door Cobrahead 03 05 07 10 13 35W S HPS 50W M MH 70W V MV 100W 100/150W wired 100W 14 100/150W wired 150W 15 150W 17 175W 20 200W 25 250W 40 400W Refer to the ballast matrix on page 56 for compatibility. Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI MR Mag Reg (3 Coil) XX No Ballast Options Distribution R2 Roadway Type II 120V R3 Roadway Type III 208V RX Roadway Type II 220V 4-way 240V 277V Refer to Optical Matrix 347V below for compatibility 480V Multi-tap wired 120V Multi-tap wired 208V Optics Multi-tap wired 240V Multi-tap wired 277V DA Drop Acrylic Tri-tap wired 120V Prismatic Refractor Tri-tap wired 277V DP Drop Polycarbonate Tri-tap wired 347V Prismatic Refractor Dual Tap 120/240 DG Drop Glass wired 120V Prismatic Refractor DT2 Dual Tap 120/240 wired 240V DT3 Dual Tap 240/480 wired 240V DT4 Dual Tap 240/480 wired 480V 120 208 220 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 Maximum number of options is six, for more options please contact your local American Electric Lighting representative Mounting (blank) 2-bolt Internal 1-1/4” setting (standard) EF External Fitter (2-bolt only) 4B 4-bolt Internal M2 2-bolt Internal 2” setting E2 External Fitter 2” Mast Arm (2-bolt only) Paint1 (blank) BK BZ WH UP Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Listing UL CS UL Listed CSA Certified Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle3 PB Phosphor Bronze Contacts Lamp LC LD LG Lamp Included, Clear Lamp Included, Deluxe/Coated Self Igniting Lamp4 Starter5 (blank) EC OP SN Open Board (standard) Encapsulated Plug-in Open Plug-in No Ignitor4 Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) 1 Other colors available, please contact your local American Electric Lighting representative 2 Voids UL/CSA Certified Options, not available in MT, TT, DT voltages 3 PB, SH, PC not available with with NR option 4 Requires SN option 5 Available in HPS only 6 Limited availability, please contact your local American Electric Lighting representative 7 Tested to withstand 3G vibration, 4B option required Optic Distribution Misc. PC BL SS CF PL LA Fusing2 SF DF Notes: 5H NN SH LCU HK BF Photocontrol Included per Voltage Specified Bubble Level Stainless Steel Fasteners (external) Charcoal Filter Distribution Pattern Indicator Label Lightning Arrestor (Void UL/CSA Certified Options) 50 Hertz Ballast Cycle6 No NEMA Label on Housing Shorting Cap Low Copper Alloy Content (less than 1%) Hinge Keeper Bridge Fitter7 03S 05S 07S 10S 15S 20S 25S 31S 40S 17M 25M 17V 25V See pages 259-264 for a complete listing of Frequently Ordered Products R2DA R3DA R2DP R3DP R2DG R3DG RXDG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ Product Guide 19 Roadway Series 315 Roadway Lighting Luminaires — Cutoff Style Cobrahead with Power Door 35-400W HPS, 100-250W MV/MH P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance. Die-cast secondary Power Pad door places all electrical components on one easily interchangeable module with quick disconnects to main fixture housing. Two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Optional four-bolt mounting provides extra security in high-vibration applications. Die-cast trigger latch on lens frame enables easy and secure one-hand opening for re-lamping. Star Friendly™ cutoff distribution patterns available. Large surface area “breathing seal” gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture. Wildlife shield is cast into the housing (not a separate piece) on the two-bolt unit and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms. Applications: Photocontrol receptacle is adjustable without tools. Roadways Residential streets Storage areas Parking lots Campuses Parks Anodized aluminum reflectors provide uniform lighting distribution with either flat or sag clear tempered glass. NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard. All electrical components warranted by American Electric Lighting's 6-year guarantee. E39 mogul socket standard. DIMENSIONS Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31 Suitable for -30°C MH & MV / -40°C HPS. 6.5" (165) 27" (686) 6.5" (165) 13" (330) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 315 with Cutoff is 0.98 sq. ft. Approx. Wt. = 19 lbs. 20 Product Guide 27" (686) 13" (330) 8.3" (211) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 315 with sag glass is 1.06 sq. ft. For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 315 Roadway Lighting Luminaires — Cutoff Style Cobrahead with Power Door 35-400W HPS, 100-250W MV/MH O R D E R I N G I N F O R M AT I O N Example: 3 1 5 1 0 S C A D T 2 R 3 F G N R H P Wattage / Source Series 315 Power Door Cobrahead 03 05 07 10 13 35W S HPS 50W M MH 70W V MV 100W 100/150W wired 100W 14 100/150W wired 150W 15 150W 17 175W 20 200W 25 250W 40 400W Refer to the ballast matrix on page 56 for compatibility. RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI MR Mag Reg (3 Coil) XX No Ballast Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Mounting (blank) 2-bolt Internal 1-1/4” setting (standard) EF External Fitter (2-bolt only) 4B 4-bolt Internal M2 2-bolt Internal 2” setting E2 External Fitter 2” Mast Arm (2-bolt only) Paint1 (blank) BK BZ WH UP Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Listing UL CS UL Listed CSA Certified Fusing2 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle3 PB Phosphor Bronze Contacts Lamp LC LD LG Lamp Included, Clear Lamp Included, Deluxe/Coated Self-Igniting Lamp4 Starter5 (blank) EC OP SN Open Board (standard) Encapsulated Plug-in Open Plug-in No Ignitor (use self-igniting lamp) Misc. PC BL SS CF PL LA 5H NN SH LCU HK HP BF Voltage Ballast Distribution R2 Roadway Type II 120V R3 Roadway Type III 208V 220V Refer to Optical Matrix 240V below for compatibility 277V 347V 480V Multi-tap wired 120V Optics Multi-tap wired 208V Multi-tap wired 240V FG Flat Glass Clear Tempered Multi-tap wired 277V SG Sag Glass Clear Tempered Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual Tap 120/240 wired 120V DT2 Dual Tap 120/240 wired 240V DT3 Dual Tap 240/480 wired 240V DT4 Dual Tap 240/480 wired 480V 120 208 220 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 Notes: Photocontrol Included per Voltage Specified Bubble Level Stainless Steel Fasteners (external) Charcoal Filter Distribution Pattern Indicator Label Lightning Arrestor (Void UL/CSA Certified Options) 50 Hertz Ballast Cycle6 No NEMA Label on Housing Shorting Cap Low Copper Alloy Content (less than 1%) Hinge Keeper High Performance7 Bridge Fitter8 1 Other colors available, please contact your local American Electric Lighting representative 2 Voids UL/CSA Certified Options, not available in MT, TT, DT voltages 3 PB, PC, SH, not available in NR option 4 Requires SN option 5 Available in HPS only 6 Limited availability, please contact your local American Electric Lighting representative 7 FG Optics only 8 Tested to withstand 3G vibration, 4B option required Optic Distribution 03S 05S 07S 10S 15S 20S 25S 40S 17M 25M 17V 25V R2SG R3SG R2FG R3FG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆1 ◆1 ◆ ◆1 ◆1 ◆ ◆1 ◆1 ◆ ◆1 ◆1 R2FGHP ◆ ◆ ◆ ◆ ◆ R3FGHP ◆ ◆ ◆ ◆ ◆ Notes: 1 Use deluxe/coated lamp LD option See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 21 Roadway Series 125 Roadway Lighting Luminaires — Cobrahead 200-400W HPS, 175-400W MH/MV P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance. Optional two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Standard fourbolt mounting provides extra security in high-vibration applications. Die-cast trigger latch on door frame enables easy and secure one-hand opening for re-lamping and maintenance. Large surface area "breathing seal" gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture. Wildlife shield is cast into the housing (not a separate piece) with 2B option and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms. Photocontrol receptacle is adjustable without tools. Anodized aluminum reflectors provide uniform lighting distribution with either borosilicate glass, or polycarbonate refractor. Applications: Roadways Residential streets Storage areas Parking lots Campuses Parks NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard. All electrical components warranted by American Electric Lighting's 6-year guarantee. E39 mogul socket standard. Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31 DIMENSIONS Suitable for -30°C MH & MV / -40°C HPS. 14" (356) 31-1/2" (800) 14" (356) 14-3/4" (375) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire series 125 is 1.30 sq. ft. Approx. Wt. = 35 lbs. 22 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 125 Roadway Lighting Luminaires — Cobrahead 200-400W HPS, 175-400W MH/MV O R D E R I N G I N F O R M AT I O N Example: 1 2 5 4 0 S C A M T 1 R 3 D G L C P C Wattage / Source Series 125 Single Door Cobrahead 17 20 25 31 40 23 175W 200W 250W 310W 400W 250/400W wired 250 24 250/400W wired 400 S HPS M MH V MV Refer to the ballast matrix on page 56 for compatibility. Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI MR Mag Reg (3 Coil) XX No Ballast Distribution R2 Roadway Type II 120V R3 Roadway Type III 208V R4 Roadway Type IV 220V 240V Refer to Optical Matrix 277V below for compatibility 347V 480V Optics Multi-tap wired 120V Multi-tap wired 208V DP Drop Polycarbonate Multi-tap wired 240V Prismatic Refractor Multi-tap wired 277V DG Drop Glass Tri-tap wired 120V Prismatic Refractor Tri-tap wired 277V Tri-tap wired 347V Dual Tap 120/240 wired 120V DT2 Dual Tap 120/240 wired 240V DT3 Dual Tap 240/480 wired 240V DT4 Dual Tap 240/480 wired 480V 120 208 220 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Mounting (blank) 4-bolt Internal (standard) M2 2-bolt Internal 2” setting 2B 2-bolt Internal 1-1/4” setting Lamp LC LD LG Lamp Included, Clear Lamp Included, Deluxe/Coated Self-Igniting Lamp4 Paint1 (blank) BK BZ WH UP Starter5 (blank) EC OP SN Open Board (standard) Encapsulated Plug-in Open Plug-in No Ignitor (use self-igniting lamp) Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Listing UL CS Fusing2 SF DF UL Listed CSA Certified Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle3 PB Phosphor Bronze Contacts Misc. PC BL SS CF PL LA 5H NN SH LCU HK BF Photocontrol Included per Voltage Specified Bubble Level Stainless Steel Fasteners (external) Charcoal Filter Distribution Pattern Indicator Label Lightning Arrestor (Void UL/CSA Certified Options) 50 Hertz Ballast Cycle6 No NEMA Label on Housing Shorting Cap Low Copper Alloy Content (less than 1%) Hinge Keeper Bridge Fitter7 Notes: 1 Other colors available, please contact your local American Electric Lighting representative 2 Voids UL/CSA Certified Options, not available with MT, TT, DT voltages 3 PB, PC, SH, not available in NR option 4 Requires SN starter option 5 Available in HPS only 6 Limited availability, please contact your local American Electric Lighting representative 7 Tested to withstand 3G vibration, 4B standard required Optic Distribution 20S 25S 31S 40S 17M 25M 40M 17V 25V 40V See pages 259-264 for a complete listing of Frequently Ordered Products R2DP R3DP R2DG R3DG R4DG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ - Product Guide 23 Roadway Series 125 Roadway Lighting Luminaires — Cutoff Style Cobrahead 200-400W HPS, 175-400W MV/MH P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance. Optional two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Standard fourbolt mounting provides extra security in high-vibration applications. Die-cast trigger latch on door frame enables easy and secure one-hand opening for re-lamping and maintenance. Star Friendly™ cutoff distribution patterns available. Large surface area “breathing seal” gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture. Wildlife shield is cast into the housing (not a separate piece) with 2B option and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms. Photocontrol receptacle is adjustable without tools. Applications: Anodized aluminum reflectors provide uniform lighting distribution with either flat or sag clear tempered glass. Roadways Residential streets Storage areas Parking lots Campuses Parks NEMA wattage label, terminal block, and photocontrol receptacle are standard. All electrical components warranted by American Electric Lighting's 6-year guarantee. E39 mogul socket standard. DIMENSIONS Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31 Suitable for -30°C MH & MV / -40°C HPS. 31-1/2" (800) 7-3/4" (197) 14-3/4" (575) 31-1/2" (800) 14-3/4" (575) 7-3/4" (197) 10" (254) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire series 125 Cutoff is 1.14 sq. ft. Approx. Wt. = 35 lbs 24 Product Guide 10" (254) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 125 with sag glass is 1.22 sq. ft. For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 125 Roadway Lighting Luminaires — Cutoff Style Cobrahead 200-400W HPS, 175 - 400W MV/MH O R D E R I N G I N F O R M AT I O N Example: 1 2 5 4 0 S C A M T 1 R 3 F G L C P C Wattage / Source Series 125 Single Door Cobrahead 17 20 25 31 40 23 175W S HPS 200W M MH 250W V MV 310W 400W 250/400W wired 250 24 250/400W wired 400 Refer to the ballast matrix on page 56 for compatibility. Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI MR Mag Reg (3 Coil) XX No Ballast Options Distribution R2 Roadway Type II 120V R3 Roadway Type III 208V 220V Refer to Optical Matrix 240V below for compatibility 277V 347V 480V Multi-tap wired 120V Optics Multi-tap wired 208V Multi-tap wired 240V FG Flat Glass Clear Tempered Multi-tap wired 277V SG Sag Glass Clear Tempered Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual Tap 120/240 wired 120V DT2 Dual Tap 120/240 wired 240V DT3 Dual Tap 240/480 wired 240V DT4 Dual Tap 240/480 wired 480V 120 208 220 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 Maximum number of options is six, for more options please contact your local American Electric Lighting representative Mounting (blank) 4-bolt Internal (standard) M2 2-bolt Internal 2” setting 2B 2-bolt Internal 1-1/4” setting Lamp LC LD LG Lamp Included, Clear Lamp Included, Deluxe/Coated Self-Igniting Lamp4 Paint1 (blank) BK BZ WH UP Starter5 (blank) EC OP SN Open Board (standard) Encapsulated Plug-in Open Plug-in No Ignitor (use self-igniting lamp) Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Listing UL CS Fusing2 SF DF UL Listed CSA Certified Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle3 PB Phosphor Bronze Contacts Misc. PC BL SS CF PL LA 5H NN SH LCU HK HP BF Notes: Photocontrol Included per Voltage Specified Bubble Level Stainless Steel Fasteners (external) Charcoal Filter Distribution Pattern Indicator Label Lightning Arrestor (Void UL/CSA Certified Options) 50 Hertz Ballast Cycle6 No NEMA Label on Housing Shorting Cap Low Copper Alloy Content (less than 1%) Hinge Keeper High Performance7 Bridge Fitter8 1 Other colors available, please contact your local American Electric Lighting representative 2 Voids UL/CSA Certified Options, not available with MT, TT, DT voltages 3 PB, PC, SH, not available in NR option 4 Requires SN starter option 5 Available in HPS only 6 Limited availability, please contact your local American Electric Lighting representative 7 FG Optics only 8 Tested to withstand 3G vibration, 4B standard required Optic Distribution 20S 25S 31S 40S 17M 25M 40M 17V 25V 40V See pages 259-264 for a complete listing of Frequently Ordered Products R2SG R3SG R2FG R3FG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ - R2 FG HP ◆ ◆ ◆ ◆ - R3 FG HP ◆ ◆ ◆ ◆ - Product Guide 25 Roadway Series 325 Roadway Lighting Luminaires — Cobrahead with Power Door 200-400W HPS, 175-400W MV/MH P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance. Die-cast secondary Power Pad door places all electrical components on one easily interchangeable module with quick disconnects to main fixture housing. Optional two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Standard four-bolt mounting provides extra security in high-vibration applications. Die-cast trigger latch on lens frame enables easy and secure one-hand opening for re-lamping. Large surface area “breathing seal” gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture. Wildlife shield is cast into the housing (not a separate piece) with 2B option and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms. Applications: Photocontrol receptacle is adjustable without tools. Roadways Residential streets Storage areas Parking lots Campuses Parks Anodized aluminum reflectors provide uniform lighting distribution with either borosilicate glass or polycarbonate refractor. NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard. All electrical components warranted by American Electric Lighting's 6-year guarantee. DIMENSIONS E39 mogul socket standard. Suitable for -30°C MH & MV / -40°C HPS. Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31 14" (356) 31-1/2" (800) 14" (356) 14-3/4" (375) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 325 is 1.30 sq. ft. Approx. Wt. = 35 lbs. 26 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 325 Roadway Lighting Luminaires — Cobrahead with Power Door 200-400W HPS, 175-400W MV/MH O R D E R I N G I N F O R M AT I O N Example: 3 2 5 4 0 M C A M T 7 R 3 D G B K L C Series 325 Power Door Cobrahead Wattage / Source 17 20 25 31 40 23 175W S HPS 200W M MH 250W V MV 310W 400W 250/400W wired 250W 24 250/400W wired 400W Refer to the ballast matrix on page 57 for compatibility. RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI XX No Ballast SC SCWA MR Mag Reg (3 Coil) Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Mounting (blank) 4-bolt Internal (standard) M2 2-bolt Internal 2” setting 2B 2-bolt Internal 1-1/4” setting Paint1 (blank) BK BZ WH UP Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Listing UL CS UL Listed CSA Certified Fusing2 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Lamp LC LD LG Lamp Included, Clear Lamp Included Deluxe/Coated Self-Igniting Lamp4 Starter5 (blank) EC OP SN Open Board (standard) Encapsulated Plug-in Open Plug-in No Ignitor (use self-igniting lamp) Misc. PC BL SS CF PL LA Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle3 PB Phosphor Bronze Contacts 5H NN SH LCU HK BF Voltage Ballast Distribution R2 Roadway Type II 120V R3 Roadway Type III 208V R4 Roadway Type IV 220V 240V Refer to Optical Matrix 277V below for compatibility 347V 480V Optics Multi-tap wired 120V Multi-tap wired 208V DP Drop Polycarbonate Multi-tap wired 240V Prismatic Refractor Multi-tap wired 277V DG Drop Glass Tri-tap wired 120V Prismatic Refractor Tri-tap wired 277V Tri-tap wired 347V Dual Tap 120/240 wired 120V DT2 Dual Tap 120/240 wired 240V DT3 Dual Tap 240/480 wired 240V DT4 Dual Tap 240/480 wired 480V 120 208 220 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 Notes: Photocontrol Included per Voltage Specified Bubble Level Stainless Steel Fasteners (external) Charcoal Filter Distribution Pattern Indicator Label Lightning Arrestor (Void UL/CSA Certified Options) 50 Hertz Ballast Cycle6 No NEMA Label on Housing Shorting Cap Low Copper Alloy Content (less than 1%) Hinge Keeper Bridge Fitter7 1 Other colors available, please contact your local American Electric Lighting representative 2 Voids UL/CSA Certified Options; not available with MT, TT, DT voltages 3 PB, PC, SH, not available in NR option 4 Requires SN starter option 5 Available in HPS only 6 Limited availability, please contact your local American Electric Lighting representative 7 Tested to withstand 3G vibration, 4B standard required Optic Distribution 20S 25S 31S 40S 17M 25M 40M 17V 25V 40V See pages 259-264 for a complete listing of Frequently Ordered Products R2DP R3DP R2DG R3DG R4DG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ - Product Guide 27 Roadway Series 325 Roadway Lighting Luminaires — Cutoff Style Cobrahead with Power Door 200-400W HPS, 175-250W MV/MH P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance. Die-cast secondary Power Pad door places all electrical components on one easily interchangeable module with quick disconnects to main fixture housing. Optional two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Standard four-bolt mounting provides extra security in high-vibration applications. Die-cast trigger latch on lens frame enables easy and secure one-hand opening for re-lamping. Star Friendly™ cutoff distribution patterns available. Large surface area “breathing seal” gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture. Wildlife shield is cast into the housing (not a separate piece) with 2B option and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms. Applications: Roadways Residential streets Storage areas Parking lots Campuses Parks Photocontrol receptacle is adjustable without tools. Anodized aluminum reflectors provide uniform lighting distribution with either flat or sag clear tempered glass. NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard. All electrical components warranted by American Electric Lighting's 6-year guarantee. DIMENSIONS E39 mogul socket standard. Suitable for -30°C MH & MV / -40°C HPS. 7-3/4" (197) Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31 31-1/2" (800) 7-3/4" (197) 31-1/2" (800) 14-3/4" (375) 10" (254) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 325 is 1.14 sq. ft. Approx. Wt. = 35 lbs 28 Product Guide Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 325 with sag glass is 1.22 sq. ft. For photometric information, visit our website, www.americanelectriclighting.com 14-3/4" (575) 10" (254) Roadway Series 325 Roadway Lighting Luminaires — Cutoff Style Cobrahead with Power Door 200-400W HPS, 175-250W MV/MH O R D E R I N G I N F O R M AT I O N Example: 3 2 5 3 1 S C A M T 1 R 3 F G S F B L Wattage / Source Series 325 Power Door Cobrahead 17 20 25 31 40 23 175W 200W 250W 310W 400W 250/400W wired 250W 24 250/400W wired 400W S HPS M MH V MV Refer to the ballast matrix on page 57 for compatibility. RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI MR Mag Reg (3 Coil) SC SCWA XX No Ballast Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Mounting (blank) 4-bolt Internal (standard) M2 2-bolt Internal 2” setting 2B 2-bolt Internal 1-1/4” setting Paint1 (blank) BK BZ WH UP Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Listing UL CS UL Listed CSA Certified Fusing2 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Lamp LC LD LG Lamp Included, Clear Lamp Included, Deluxe/Coated Self-Igniting Lamp4 Starter5 (blank) EC OP SN Open Board (standard) Encapsulated Plug-in Open Plug-in No Ignitor (use self-igniting lamp) Misc. PC BL SS CF PL LA Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle3 PB Phosphor Bronze Contacts 5H NN SH LCU HK HP BF Voltage Ballast Distribution R2 Roadway Type II 120V R3 Roadway Type III 208V 220V Refer to Optical Matrix 240V below for compatibility 277V 347V 480V Optics Multi-tap wired 120V Multi-tap wired 208V FG Flat Glass Clear Tempered Multi-tap wired 240V SG Sag Glass Clear Tempered Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual Tap 120/240 wired 120V DT2 Dual Tap 120/240 wired 240V DT3 Dual Tap 240/480 wired 240V DT4 Dual Tap 240/480 wired 480V 120 208 220 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 Notes: Photocontrol Included per Voltage Specified Bubble Level Stainless Steel Fasteners (external) Charcoal Filter Distribution Pattern Indicator Label Lightning Arrestor (Void UL/CSA Certified Options) 50 Hertz Ballast Cycle6 No NEMA Label on Housing Shorting Cap Low Copper Alloy Content (less than 1%) Hinge Keeper High Performance7 Bridge Fitter8 1 Other colors available, please contact your local American Electric Lighting representative 2 Voids UL/CSA Certified Options; not available with MT, TT, DT voltages 3 PB, PC, SH, not available in NR option 4 Requires SN option 5 Available in HPS only 6 Limited availability, please contact your local American Electric Lighting representative 7 Available with FG optics only 8 Tested to withstand 3G vibration, 4B standard required Optic Distribution 20S 25S 31S 40S 17M 25M 40M 17V 25V 40V See pages 259-264 for a complete listing of Frequently Ordered Products R2SG R3SG R2FG R3FG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ - R2 FG HP R3 FG HP ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ - Product Guide 29 Roadway Series 327 Roadway Lighting Luminaires — Cobrahead 310-1000W HPS, 750-1000W MV/MH P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance. Four-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (32mm to 51mm) diameter and extra security in highvibration applications. Die-cast trigger latch on door frame enables easy and secure one-hand opening for re-lamping and maintenance. Large surface area “breathing seal” gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture. Anodized aluminum reflectors provide uniform lighting distribution with standard borosilicate glass refractor. Photocontrol receptacle is adjustable without tools. NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard. Applications: Roadways Residential streets Storage areas Parking lots Campuses Parks All electrical components warranted by American Electric Lighting's 6-year guarantee. E39 mogul socket standard. Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17 Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS 16-1/4" (413) 38.3" (973) 16-1/4" (413) 17-1/2" (445) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 327 is 1.96 sq. ft. Approx. Wt. = 35 lbs 30 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 327 Roadway Lighting Luminaires — Cobrahead 310-1000W HPS, 750-1000W MV/MH O R D E R I N G I N F O R M AT I O N Example: 3 2 7 X 1 M C A M T 1 R 3 D G L C P C Wattage / Source Series 327 Single Door Cobrahead 31 310W S HPS 40 400W M MH 75 750W V MV X1 1000W Refer to the ballast matrix on page 57 for compatibility. Voltage Ballast CA CT MR SC XX CWA CWI Mag Reg (3 Coil) SCWA No Ballast Distribution 120 208 220 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 120V 208V 220V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual Tap 120/240 wired 120V DT2 Dual Tap 120/240 wired 240V DT3 Dual Tap 240/480 wired 240V DT4 Dual Tap 240/480 wired 480V R1 R2 R3 R4 Roadway Type I Roadway Type II Roadway Type III Roadway Type IV Refer to Optical Matrix below for compatibility Optics DG Drop Glass Prismatic Refractor Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Paint1 (blank) BK BZ WH UP Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Fusing2 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle3 PB Phosphor Bronze Contacts Lamp LC LD Misc. PC BL SS PL LA NN SH Notes: Lamp Included, Clear Lamp Included, Deluxe/Coated Photocontrol Included per Voltage Specified Bubble Level Stainless Steel Fasteners (external) Distribution Pattern Indicator Label Lightning Arrestor No NEMA Label on Housing Shorting Cap 1 2 3 Other colors available, please contact your local American Electric Lighting representative Not available with MT, TT, DT voltages PB, PC, SH not available with NR option Optic Distribution 31S 40S X1S X1V X1M R1DG R2DG R3DG R4DG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆1 ◆ ◆ ◆ - Notes: 1 Use deluxe/coated lamp LD option See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 31 Roadway Series 413 Roadway Lighting Luminaires — Cobrahead 35-150W HPS P R O D U C T O V E R V I E W Features: Compact size for economical street lighting. Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance. Two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Stainless steel latch enables easy one-hand opening for re-lamping and maintenance. Star Friendly™ cutoff distribution patterns available. Large surface area “breathing seal” gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture. Wildlife shield is cast into the housing (not a separate piece) and is easily adjustable for 1-1/4" to 2" (32mm to 51mm) mast arms. Photocontrol receptacle is adjustable without tools. Applications Anodized aluminum reflector provides uniform lighting distribution with either flat lens, drop acrylic, drop polycarbonate, drop glass or sag glass. Roadways Residential streets Storage areas Parking lots Campuses Parks All electrical components warranted by American Electric Lighting's 6-year guarantee. Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31 Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS 6.830" (174) 21" (533) 11.5" (292) 12.8" (325.12) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 413 Drop lens is 0.80 sq. ft. (.074 m2). The EPA for the Horizontal Luminaire Series 413 Flat lens is 0.61 sq. ft. (.057 m2). Approx. Wt. = 16 lbs. 32 Product Guide 21" (533) Effective Projected Area (EPA) The EPA for the Series 413 sag lens is .69 For photometric information, visit our website, www.americanelectriclighting.com 12.8" (325) Roadway Series 413 Roadway Lighting Luminaires — Cobrahead 35-150W HPS O R D E R I N G I N F O R M AT I O N Example: 4 1 3 1 5 S R N 1 2 0 R 3 D A L C Wattage / Source Series 413 Single Door Cobrahead 03 05 07 10 15 35W 50W 70W 100W 150W S HPS Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XX No Ballast Distribution R2 Roadway Type II R3 Roadway Type III 120 120V 240 240V Refer to Optical Matrix below for compatibility Refer to the ballast matrix on page 58 for compatibility. Optics DA Drop Acrylic Prismatic Refractor DP Drop Polycarbonate Prismatic Refractor DG Drop Glass Prismatic Refractor FG Flat Glass Clear Tempered Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Paint1 (blank) BK BZ WH UP Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle2 PB Phosphor Bronze Contacts Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Misc. PC SS CF PL 5H NN LA SH Notes: Photocontrol Included per Voltage Specified Stainless Steel Fasteners (external) Charcoal Filter Distribution Pattern Indicator Label 50 Hertz Ballast Cycle3 No NEMA Label on Housing Lightning Arrestor Shorting Cap 1 Other colors available, please contact your local American Electric Lighting representative 2 PB, PC, SH not available with NR option 3 Limited availability, please contact your local American Electric Lighting representative Optic Distribution 03S 05S 07S 10S 15S See pages 259-264 for a complete listing of Frequently Ordered Products R2DA R2DP R2DG R3DG R2FG R3FG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ Product Guide 33 Multi-Mount™ Series 285 Roadway Lighting Luminaires — Set-Back 200-400W HPS, 250-400W MV/MH P R O D U C T O V E R V I E W Features: Unique optical design allows set-back of mounting poles away from traffic areas, still while delivering superior performance. Light pattern allows exceptional spacing to mounting height ratios, permitting fewer luminaries per mile. Anodized aluminum reflector provides uniform lighting distribution with drop acrylic prismatic refractor. Adjustable and locking knuckle mount provides for precise and secure aiming of the luminaire. Latch on lens frame enables easy and secure one-handed opening for re-lamping. Photocontrol receptacle is adjustable without tools. All electrical components warranted by American Electric Lighting's 6-year guarantee. Suitable for -30°C MH & MV / -40°C HPS. Applications: Complies with ANSI: C136.2, C136.10, C136.15, C136.31 Interstate roadways Broad commercial and residential roadways Large parking areas DIMENSIONS 27-1/4" (692) 3" (76) 5-1/4" (133) 17" (432) 11-1/4" (286) Effective Projected Area (EPA) The EPA for the Multi-Mount™ Luminaire Series 285 is 2.8 sq. ft. Approx Wt. = 42 lbs 34 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Multi-Mount™ Series 285 Roadway Lighting Luminaires — Set-Back 200-400W HPS, 250-400W MV/MH O R D E R I N G I N F O R M AT I O N Example: 2 8 5 4 0 S C A M T 1 R 3 D A L C Wattage / Source Series 285 Multi-Mount Roadway S HPS M MH V MV 20 25 31 40 23 200W 250W 310W 400W1 250/400W wired 250 24 250/400W wired 400 Voltage Ballast Refer to the ballast matrix on page 58 for compatibility. RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI MR Mag Reg (3 Coil) 120 208 220 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 DT2 DT3 DT4 120V 208V 220V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual Tap 120/240 wired 120V Dual Tap 120/240 wired 240V Dual Tap 240/480 wired 240V Dual Tap 240/480 wired 480V Distribution R3 Roadway Type III2 Optics DA Drop Acrylic Prismatic Refractor Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Paint3 (blank) BK WH UP GY Bronze (standard) Black White Unpainted Gray Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 and L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Fusing4 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle5 PB Phosphor Bronze Contacts Lamp LC LD LG Lamp Included, Clear Lamp Included, Deluxe/Coated Self-Igniting Lamp6 Starter7 (blank) EC OP SN Open Board (standard) Encapsulated Plug-in Open Plug-in No Ignitor (use self-igniting lamp) Misc. PC HK SS PL LA NL SH Notes: 1 2 3 4 5 6 7 400 MH requires reduced jacket ED-28 lamp Distribution depends on tilt angle of fixture Other colors available, please contact your local American Electric Lighting representative Not available with MT, TT, DT voltages PB, PC, SH not available with NR option Requires SN option For HPS only Photocontrol Included per Voltage Specified Hinge Keeper Stainless Steel Fasteners (external) Distribution Pattern Indicator Label Lightning Arrestor NEMA Label Shorting Cap See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 35 InterState™ II Series 775 Roadway Lighting Luminaires — Interstate with Contemporary Style 200-400W HPS, 175-400W MH, 250-400W MV P R O D U C T O V E R V I E W Features: Unique optical design allows set-back of mounting poles away from traffic areas, while still delivering superior performance. Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance. Slim profile provides a low E.P.A. Door is hinged and easily removable for quick maintenance. Anodized aluminum reflector provides uniform lighting distribution with sag or flat glass clear tempered refractor. Adjustable and locking knuckle mount provides for precise and secure aiming of the luminaire. Photocontrol receptacle is adjustable without tools. Easy single fastener closure for fast relamping and optional tool-less access available. NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard. Applications: All electrical components warranted by American Electric Lighting's 6-year guarantee. Interstate roadways Expressways Railway switchyards Shipping docks Large parking lots Suitable for -30°C MH & MV / -40°C HPS. Complies with ANSI: C136.2, C136.3, C136.10, C136.15, C136.31 DIMENSIONS 17.75" (451) 7" (178) 23" (584) 2" (51) 19.5" (495) 7" (178) 17.75" (451) 21.13" (537) 19.5" (495) 1" (25) 2" (51) .44" (11) Dia. .78" (20) Dia. 1" (25) 2" (51) Effective Projected Area (EPA) The EPA for the InterState™ II is 2.75 sq. ft. Approx. Wt. = 37 lbs 36 Product Guide For photometric information, visit our website, www.americanelectriclighting.com InterState™ II Series 775 Roadway Lighting Luminaires — Interstate with Contemporary Style 200-400W HPS, 175-400W MH, 250-400W MV O R D E R I N G I N F O R M AT I O N Example: 7 7 5 4 0 S C A 4 8 0 R 3 S G Wattage / Source Series 775 InterState Roadway Offset Voltage Distribution 120V 208V 220V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual Tap 120/240 wired 120V DT2 Dual Tap 120/240 wired 240V DT3 Dual Tap 240/480 wired 240V DT4 Dual Tap 240/480 wired 480V R3 Roadway Type III1 Ballast 17 20 25 31 40 23 175W S HPS 200W M MH 250W V MV 310W 400W 250/400W wired 250W 24 250/400W wired 400W RN RH XN XH Refer to the ballast matrix on page 58 for compatibility. CA CT MR SC Reactor Normal Power Factor Reactor High Power Factor High Reactance (Lag) Normal Power Factor High Reactance (Lag) High Power Factor CWA CWI Mag Reg (3 Coil) SCWA 120 208 220 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 Optics SG Sag Glass Clear Tempered FG Flat Glass Clear Tempered Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Mounting (blank) Tenon Slipfitter (standard)2 YG Yoke Galvanized YP Yoke Painted2 Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle5 Paint3 (blank) BK BZ WH UP Lamp LC LD LG Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 and L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Standard Listing (blank) UL Listed (standard) CS CSA Certified Fusing4 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Starter7 (blank) EC OP SN Misc. PC TL BT SS PL LA 5H NN SH Notes: Lamp Included, Clear Lamp Included, Deluxe/Coated Self-Igniting Lamp6 Open Board (standard) Encapsulated Plug-in Open Plug-in No Ignitor (use self-igniting lamp) 1 2 3 4 5 6 7 8 Distribution depends on tilt angle of fixture Painted to match specified color of fixture Other colors available, please contact your local American Electric Lighting representative Voids UL/CSA Certified Options, not available with MT, TT, DT voltages PB, PC, SH not available with NR option Requires SN starter option For HPS Products only Limited availability, please contact your local American Electric Lighting representative Photocontrol Included per Voltage Specified Tool Less Entry Ballast Tray Stainless Steel Fasteners (external) Distribution Pattern Indicator Label Lightning Arrestor 50 Hertz Ballast Cycle8 Less NEMA Label Shorting Cap See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 37 LPS Roadway Series SRP Roadway Lighting Luminaires 90-180W LPS P R O D U C T O V E R V I E W Features: Designed for maximum energy savings with efficient light distribution. Outside housing constructed of non-corrosive ABS plastic with UV inhibiting coating. Drop acrylic or polycarbonate prismatic refractor and adjustable socket allows for maximum control of light distribution. Photocontrol receptacle is adjustable without tools. All electrical components warranted by American Electric Lighting's 6-year guarantee. Suitable for -30°C MH & MV / -40°C HPS. Complies with ANSI: C136.2, C136.10, C136.15 Applications: Roadways Highways Transportation terminals Security lighting DIMENSIONS 14" 10" L" Mounting end of tenon must have a 6-3/4" straight section (min.) Accepts 1-1/2" to 2" OD Mounting 10" (254) 7" (179) SERIES LENGTH (L) EPA (Sq. Ft.) SRP90 55'' 1.45 SRP13 55'' 1.45 SRP18 65'' 1.86 Approx. Wt. = 51 lbs 38 Product Guide For photometric information, visit our website, www.americanelectriclighting.com LPS Roadway Series SRP Roadway Lighting Luminaires 90-180W LPS O R D E R I N G I N F O R M AT I O N Example: S R P 1 8 L X H 4 8 0 R 4 D A D F Series SRP Low Pressure Sodium Roadway Wattage / Source 09 90W 13 135W 18 180W L Low Pressure Sodium Refer to the ballast matrix on page 59 for compatibility. Voltage Distribution Optics 120V 208V 240V 277V 347V 480V Dual Tap wired 120/240 wired 120V DT2 Dual Tap wired 120/240 wired 240V DT5 Dual Tap 208/277 wired 208V DT6 Dual Tap 208/277 wired 277V R4 Roadway Type IV DA Drop Acrylic Prismatic Refractor DP Drop Polycarbonate Prismatic Refractor Ballast RH Reactor High Power Factor XH High Reactance (Lag) High Power Factor 120 208 240 277 347 480 DT1 Options Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) PB Phosphor Bronze Contacts NR No Photocontrol Receptacle1 Fusing2 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Lamp LC Lamp Included, Clear Misc. PC Notes: 1 PB, PC, SH not available with NR option 2 Not available with DT voltages Photocontrol Included per voltage specified See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 39 LPS Roadway Series SRX Roadway Lighting Luminaires 35-90W LPS P R O D U C T O V E R V I E W Features: Designed for maximum energy savings with efficient light distribution. Vandal resistant, rugged and corrosion resistant die cast aluminum housing. Drop acrylic or polycarbonate prismatic refractor allows for maximum control of light distribution. Large surface area "breathing seal," gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture. All electrical components warranted by American Electric Lighting's 6-year guarantee. Suitable for -30°C MH & MV / -40°C HPS. Complies with ANSI: C136.2, C136.10 Applications: Roadways Highways Transportation terminals DIMENSIONS Accepts 1.625" to 2.375" ODA tenon 4.5" (114) 4" (102) 27" (686) 7.5" (191) 9" (229) Mounting end of tenon must have a 4.5" straight section (min.) Effective Projected Area (EPA) The EPS for the Roadway Luminaire Series SRX is 1.00 sq. ft. Approx. Wt. = 20 lbs. 40 Product Guide For photometric information, visit our website, www.americanelectriclighting.com LPS Roadway Series SRX Roadway Lighting Luminaires 35-90W LPS O R D E R I N G I N F O R M AT I O N Example: S R X 0 9 L R H 4 8 0 R 1 D A L C Wattage / Source Series SRX Low Pressure Sodium Roadway 03 35W 55 55W 09 90W L LPS Refer to the ballast matrix on page 59 for compatibility. Voltage Ballast RH Reactor High Power Factor XH High Reactance (Lag) High Power Factor 120 208 240 277 347 480 DT1 120V 208V 240V 277V 347V 480V Dual Tap 120/240 wired 120V DT2 Dual Tap 120/240 wired 240V DT5 Dual Tap 208/277 wired 208V DT6 Dual Tap 208/277 wired 277V Distribution R4 Roadway Type IV Optics DA Drop Acrylic Prismatic Refractor DP Drop Polycarbonate Prismatic Refractor Options Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard)1 NR No Photocontrol Receptacle PB Phosphor Bronze Contacts Lamp LC Lamp Included, Clear Misc. PC SH Photocontrol Included per Voltage Specified Shorting Cap Notes: 1 PB, PC, SH not available with NR option See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 41 LPS Roadway Series SP2 Roadway Lighting Luminaires 90-180W LPS P R O D U C T O V E R V I E W Features: Designed for maximum energy savings with efficient light distribution. Outside housing constructed of non-corrosive ABS plastic with UV inhibiting coating. Drop acrylic or polycarbonate prismatic refractor allows for maximum control of light distribution. All electrical components warranted by American Electric Lighting's 6-year guarantee. Suitable for -30°C MH & MV / -40°C HPS. Applications: Roadways Highways Security lighting Transportation terminals DIMENSIONS 6-3/4" (171) L" ARMS Accepts 1-1/2" to 2" OD Mounting 10" (254) 7" (179) SERIES LENGTH (L) EPA (Sq. Ft.) SP290 397/16'' 1.00 SP213 497/16'' 1.20 SP218 637/16'' 1.45 Approx. Wt. = 31 lbs 42 Product Guide For photometric information, visit our website, www.americanelectriclighting.com LPS Roadway Series SP2 Roadway Lighting Luminaires 90-180W LPS O R D E R I N G I N F O R M AT I O N Example: S P 2 1 8 L X H 4 8 0 R 4 D P L C Series Wattage / Source 09 90W 13 135W 18 180W SP2 Low Pressure Sodium Roadway L LPS Refer to the ballast matrix on page 59 for compatibility. Voltage Ballast RH Reactor High Power Factor XH High Reactance (Lag) High Power Factor 120 208 240 277 347 480 DT1 120V 208V 240V 277V 347V 480V Dual Tap wired 120/240 wired 120V DT2 Dual Tap wired 120/240 wired 240V DT5 Dual Tap 208/277 wired 208V DT6 Dual Tap 208/277 wired 277V Distribution R4 Roadway Type IV Optics DA Drop Acrylic Prismatic Refractor DP Drop Polycarbonate Prismatic Refractor Options Listing CS Notes: CSA Certified 1 PB, PC, SH not available with NR option Photocontrol Receptacle (blank) With Photocontrol Receptacle PB Phosphor Bronze Contacts NR No Photocontrol Receptacle1 Lamp LC Lamp Included, Clear Misc. PC SH Photocontrol Included per Voltage Shorting cap See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 43 Underpass Series GST Roadway Lighting Luminaires 55W LPS P R O D U C T O V E R V I E W Features: NEW Utilizes high lumen/watt low pressure sodium lamp for maximum energy efficiency. Rugged water tight seal for underpass, subway, and steel mill applications. Injection molded prismatic polycarbonate refractor to lesson vandalism. Suitable for high pressure hose down. Housing constructed of cast corrosion resistant 380 aluminum alloy. Aluminum reflector is finished in gloss white paint to optimize optical distribution of light. Applications: Office complexes Shopping centers and malls Schools and hospitals Parking garages Tunnels and underpasses Parks DIMENSIONS 12" (305) 8.75" (222) 27.5" (699) 8.5" (216) Approx. Wt. = 31 lbs 44 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Underpass Series GST Roadway Lighting Luminaires 55W LPS O R D E R I N G I N F O R M AT I O N Example: G S T 5 5 L X H D T 1 R 1 D P Wattage / Source Series GST Underpass Low Pressure Sodium 55 55 W L LPS Voltage Ballast XH High Reactance (Lag) High Power Factor 120 208 240 277 347 480 DT1 DT2 DT3 DT8 120V 208V 240V 277V 347V 480V Dual Tap 120/240 wired 120V Dual Tap 120/240 wired 240V Dual Tap 240/480 wired 240V Dual Tap 240/480 wired 480V Distribution R1 Roadway Type I Optics DP Drop Polycarbonate Prismatic Refractor Options Lamp LC Lamp Included, Clear See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 45 Underpass Series 581/681 Roadway Lighting Luminaires 50-250W HPS, 100-250W MV, 175-250W MH P R O D U C T O V E R V I E W Features: Low profile design for unobtrusive surface mounting. Die-cast aluminum back housing with choice of die-cast front housing with borosilicate glass lens, or one-piece polycarbonate front housing and lens. Designed for easy access to electrical compartment and optical assembly for installation and maintenance ease. All exterior hardware is captive. UL and CSA listed for wet locations. All electrical components warranted by American Electric Lighting's 6-year guarantee. E39 mogul socket standard. Suitable for -30°C MH & MV / -40°C HPS. Optional (GY) Gray finish shown Applications: Office complexes Shopping centers and malls Schools and hospitals Parking garages Tunnels and underpasses Parks DIMENSIONS 14-7/8" (378) 16-5/8" (424) 14-7/8" (378) 7" (179) 8-9/16" (251) Approx. Wt. = 30 lbs 46 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Underpass Series 581/681 Roadway Lighting Luminaires 50-250W HPS, 100-250W MV, 175-250W MH O R D E R I N G I N F O R M AT I O N Example: 5 8 1 2 5 S C A M T 1 G Y Wattage / Source Series 581 Wall pack w/ die-cast and glass front housing 681 Wall pack w/ polycarbonate front housing1 S HPS 05 50 W M MH 07 70 W V MV 10 100 W 15 150 W 17 175 W 20 200 W 25 250 W Refer to the ballast matrix on page 59 for compatibility. Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI XX No Ballast 120 208 240 277 347 480 MT1 MT2 MT7 MT8 TT1 TT7 TT3 DT1 DT2 DT3 DT4 120V 208V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 240V Multi-tap wired 277V Multi-tap wired 208V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual Tap 120/240 wired 120V Dual Tap 120/240 wired 240V Dual Tap 240/480 wired 240V Dual Tap 240/480 wired 480V Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Mounting (blank) Wall mount (standard) Paint2 (blank) BK WH GY UP Bronze (standard) Black White Gray Unpainted Listing (blank) CS UL Listing (standard) CSA Certified Fusing3 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol (blank) Button control is standard (multi-volt options not available) NC No Photocontrol Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Misc. SE SS 5H NL Side Entry Stainless Steel Fasteners (external) 50 Hertz Ballast Cycle4 NEMA Label Notes: 1 2 3 4 See pages 259-264 for a complete listing of Frequently Ordered Products Max Wattage 175W, only available in bronze Other colors available, please contact your local American Electric Lighting representative Voids UL/CSA Certified Options, not available with MT, TT, DT voltages Limited availability, please contact your local American Electric Lighting representative Product Guide 47 Heavy-Duty Wallpack Series 882 Building-Mounted Luminaires 250 & 400W HPS/MH P R O D U C T O V E R V I E W Features: Designed for easy access to electrical compartment and optical assembly for installation and maintenance ease. Heavy duty, two piece, die cast aluminum housing with hinged, captive bezel and corrosion resistant hardware. Completely sealed with high temperature silicone gasket. High impact and heat resistant borosilicate glass refractor. One piece, stippled, asymmetric anodized aluminum reflector designed to produce a wide pattern of efficient illumination. UL and CSA certified for wet locations. All electrical components warranted by American Electric Lighting's 6-year guarantee. Suitable for -30°C MH & MV / -40°C HPS. Applications: Parking areas Perimeter lighting Entrances and walkways Waterfront areas Loading platforms Recreational areas DIMENSIONS 17" (432) 12-3/4" (324) 9" (229) Approx. Wt. = 36 lbs 48 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Heavy-Duty Wallpack Series 882 Building-Mounted Luminaires 250 & 400W HPS/MH O R D E R I N G I N F O R M AT I O N Example: 8 8 2 2 5 S C A M T 1 Wattage / Source Series 882 Wall Pack 25 250W 40 400W S HPS M MH Refer to the ballast matrix on page 60 for compatibility. Voltage Ballast CA CWA CT CWI MR Mag Reg 480 MT1 MT2 MT7 MT8 TT1 TT7 TT3 480V Multi-tap wired 120V Multi-tap wired 240V Multi-tap wired 277V Multi tap wired 208V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Options Listing (blank) CS UL Listed (standard) CSA Certified Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 49 Signlite Series 875 Sign Light 175-400W MV, 175-400W MH, 100-400W HPS P R O D U C T O V E R V I E W Features: Die cast low copper aluminum housing offers light weight and corrosion resistance with excellent durability. Hinged door is easily removable for quick maintenance, single fastener makes relamping easy (optional tool-less entry available). Anodized aluminum reflector provides uniform lighting distribution with sag or flat clear tempered glass lens. UL listed for wet locations. All electrical components warranted by American Electric Lighting's 6-year guarantee. Suitable for -30°C MH & MV / -40°C HPS. Complies with ANSI: C136.2, C136.10, C136.15 Applications: Interstate highways Outdoor advertising signs Traffic flow signs Building facades Security lighting Corporate and building lighting Other vertical surfaces, watts DIMENSIONS 17.75" (451) 7" (178) 23" (584) 19.5" (495) 2" (51) 7" (178) 17.75" (451) 21.13" (537) 19.5" (495) 1" (25) 2" (51) .44" (11) Dia. .78" (20) Dia. 1" (25) 2" (51) Effective Projected Area (EPA) The EPA for the Signlite Luminaire, Series 875 is 2.75 sq. ft. Approx. Wt. = 37 lbs 50 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Signlite Series 875 Sign Light 175-400W MV, 175-400W MH, 100-400W HPS O R D E R I N G I N F O R M AT I O N Example: 8 7 5 4 0 M C A 4 8 0 6 6 S G Wattage / Source Series 875 Sign Light Voltage Ballast S HPS 100W M MH 150W V MV 175W 200W 250W 310W 400W 250/400W wired 250W 24 250/400W wired 400W Refer to the ballast matrix on page 60 for compatibility. 10 15 17 20 25 31 40 23 RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor CA CWA Auto Reg CT CWI MR Mag Reg (3 Coil) SC SCWA 120 208 220 240 277 347 480 MT1 MT2 MT7 MT8 TT1 TT7 TT3 DT1 DT2 DT3 DT4 120V 208V 220V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 240V Multi-tap wired 277V Multi-tap wired 208V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual Tap 120/240 wired 120V Dual Tap 120/240 wired 240V Dual Tap 240/480 wired 240V Dual Tap 240/480 wired 480V Distribution1 56 5H X 6V NEMA distribution 66 6H X 6V NEMA distribution Optics SG Sag Glass Clear Tempered FG Flat Glass Clear Tempered Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Mounting (blank) Tenon Mount (standard)2 YG Yoke Galvanized YP Yoke Painted2 Photocontrol Receptacle (blank) Photocontrol Receptacle (standard) NR No Photocontrol Receptacle5 PB Phosphor Bronze Contacts Paint3 (blank) BK BZ WH UP Lamp LC LD SL Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 and L2 Position T3 3 Wire Operation (L1, N, L2 Position) Listing (blank) CS UL Listed (standard) CSA Certified Fusing4 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Notes: 3 Lamp Included, Clear Lamp Included, Deluxe/Coated Self-Igniting Lamp6 Starter7 EC Encapsulated Plug-in OP Open Plug-in SN No Ignitor (using self-igniting lamp) Misc. TL BT SS CF LA PC 5H NL SH 1 2 Tool-less Entry Ballast Tray Stainless Steel Fasteners (external) Charcoal Filter Lightning Arrestor (Void UL/CSA Listed Options) Photocontrol Included per Voltage Specified 50 Hertz Ballast Cycle8 NEMA Label Shorting Cap See pages 259-264 for a complete listing of Frequently Ordered Products 4 5 6 7 8 Distribution depends on tilt angle of fixture Painted to match specified color of fixture Other colors available, please contact your local American Electric Lighting representative Voids UL/CSA Certified Options; not available with MT, TT, DT voltages PB, PC, and SH not available with NR option Requires SN option Available in HPS only Limited availability, please contact your local American Electric Lighting representative Product Guide 51 Accessories AVA I L A B I L I T Y Roadway 115-GS 115-HS1 413-GS 413-HS1 125-GS 125-HS1 581-VS2 581-WG2 882-VS2 882-WG2 882-PEC 115 ◆ ◆ - 315 ◆ - 413 ◆ ◆ - 125 325 ◆ ◆ ◆ - 327 20 - 30 - 185 - 285 775 SRP SRX - SP2 581 ◆ ◆ - Shields/Guards HS GS VS WG 52 Houseside shield Glare shield Vandal proof shield Wire guard Product Guide Notes: 1 Drop lens only 2 Vandal shield and wire guard can not be used simultaneously For photometric information, visit our website, www.americanelectriclighting.com 882 ◆ ◆ ◆ Accessories S H I E L D S Description Catalog Number 115-GS GLARE SHIELD 125-GS FOR COBRAHEAD SERIES 115-HS HOUSE SIDE SHIELD 413-HS 125-HS POLYCARBONATE SHIELD FOR SIDELITE 581 BALLISTIC SHIELDS 581-VS 115 or 315 PGS FL 25W 115 or 315 PGS FL 25W SPS 115 or 315 PGS DL 25W 115 or 315 PGS DL 250 SPS 125 or 325 PGS FL 40W 125 or 325 PGS FL 40W SPS 125 or 325 PGS DL 40W 125 or 325 PGS DL 40W SPS 6.25" (159) 8.67" (220) WIRE GUARDS 6.50" (194) 16.63" (422) 17.00" (432) 581 WG 882-WG 6.50" (165) See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 53 Roadway Lighting B A L L A S T M AT R I C E S DuraStar™ Series 20 Watts 03S 05S 07S 10S 10V 15S 17V 17M 120 RN RH,RN,XN XH,RH,CA,CT,RN,XN,MR XH,XN,CA,CT,MR,RH,RN XH,XN XH,RH,CA,CT,MR,RN,XN RH,XN CA,CT 208 XN XH,CA,CT,MR,XN XH,CA,CT,MR,XN CA,CT XH,CA,CT,MR,XN CA,CT CA,CT 220 RH RN - 240 XN XH,CA,CT,MR,XN XH,CA,CT,MR,XN RH,RN XH,RH,CA,CT,MR,RN,XN RH,RN CA,CT 277 XN XH,CA,CT,MR,XN CA,CT,XH,MR,XN CA,CT XH,CA,CT,MR,XN CA,CT,RH,RN, CA,CT 480 XH,XN CA,CT,MR CA,CT,MR CA,CT DT1 XN XN,CA CA,CT,XH,MR,XN CA,CT XH,XN,CA,CT,MR CA,CT CA,CT DT2 CA,CT,MR CA,CT,MR,XH CA,CT XH,XN,CA,CT,MR CA,CT CA,CT DT3 CA,CT CA,CT - DT4 CA,CT,MR CA,CT CA,CT - DuraStar™ Series 20 continued Watts 03S 05S 07S 10S 10V 15S 17V 17M MT1 XN XN,XH CA,CT,XN,XH CA,CT XN,XH,CA,CT XN,XH XN,XH,CA,CT MT2 XN XN,XH CA,CT, XN,XH CA,CT XN,XH,CA,CT XN,XH XN,XH,CA,CT MT7 XN XN,XH CA,CT,XN,XH CA,CT XN,XH,CA,CT XN,XH XN,XH,CA,CT MT8 XN XN,XH CA,CT,XN,XH CA,CT XN,XH XN,XH XN,XH,CA,CT TT1 XN,XH XN,XH XN,XH XN,XH - TT7 XN,XH XN,XH XN,XH XN,XH - TT3 XN,XH XN,XH XN,XH XN,XH - DuraStar™ Series 30 Watts 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 23/24M 120 XH,XN CA,CT XH,CA,CT,MR,,XN XH,XN,CA,CT,MR XH,XN,CA,CT CA,CT MR XH,XN,CA,CT,MR XH,XN CA,CT CA,CT, CA,CT, 208 CA,CT CA,CT CA,CT,MR CA,CT,MR CA,CT CA,CT MR CA,CT,MR CA,CT CA,CT CA,CT CA,CT 220 RH,RN RH RH,CA,CT RN,RH RH,CA,CT RH,,RN - 240 RH,RN ,CA,CT XH,CA,CT,MR,XN RH.RN,CA,CT,XH,MR,XN RH.RN,CA,CT CA,CT RH,MR,RN RH,RN,CA,CT, RH,RN,CA,CT, CA,CT CA,CT CA,CT 277 CA,CT,RH,RN CA,CT CA,CT,MR CA,CT,MR CA,CT CA,CT MR MR RH,CA,CT,RN CA,CT CA,CT CA,CT 347 CA,CT CA,CT CA,CT CA,CT CA,CT - 480 CA,CT CA,CT,MR CA,CT,MR CA,CT MR CA,CT,MR CA,CT CA,CT CA,CT DT1 CA,CT CA,CT XH,XN CA,CT,XH,MR,XN CA,CT CA,CT MR MR CA,CT CA,CT CA,CT CA,CT DT2 CA.CT CA.CT XH,XN,CA,CT,MR CA,CT CA,CT MR MR CA,CT CA,CT CA,CT CA,CT DuraStar™ Series 30 continued Watts 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 23/24M 54 DT3 CA,CT,MR CA,CT MR CA,CT - Product Guide DT4 CA,CT,MR CA,CT MR CA,CT - MT1 XN,XH,CA,CT XN,XH,CA,CT CA,CT,MR,XH,XN CA,CT,MR,XH,XN XN,XH,CA,CT XN,XH,CA,CT MR CA,CT,MR,XH,XN XN,XH,CA,CT XN,XH,CA,CT XN,XH,CA,CT XN,XH,CA,CT MT2 XN,XH,CA,CT XN,XH,CA,CT CA,CT,MR,XH,XN CA,CT,MR,XH,XN XN,XH,CA,CT XN,XH,CA,CT MR CA,CT,MR,XH,XN XN,XH,CA,CT XN,XH,CA,CT XN,XH,CA,CT XN,XH,CA,CT MT7 XN,XH,CA,CT XN,XH,CA,CT CA,CT,MR,XH,XN CA,CT,MR,XH,XN XN,XH,CA,CT XN,XH,CA,CT MR CA,CT,MR,XH,XN XN,XH,CA,CT XN,XH,CA,CT XN,XH XN,XH,CA,CT For photometric information, visit our website, www.americanelectriclighting.com MT8 XN,XH,CA,CT XN,XH,CA,CT CA,CT,MR,XH,XN CA,CT,MR,XH,XN XN,XH,CA,CT XN,XH,CA,CT MR CA,CT,MR,XH,XN XN,XH,CA,CT XN,XH,CA,CT XN,XH,CA,CT XN,XH,CA,CT TT1 XN,XH CA CA CA CA CA CA - TT7 XN,XH CA CA CA CA CA CA - TT3 XN,XH CA CA CA CA CA CA - Roadway Lighting B A L L A S T M AT R I C E S Roadway 115 Watts 03S 05S 07S 10S 10V 15S 13S 14S 17V 17M 20S 25S 25V 25M 40S 120 RN,RH RH,RN RH,CA,CT,RN,MR CA,CT,MR,RH,RN XH,XN,CA,CT RN,RH,CA,CT,MR RN,RH RN,RH XN,XH,CA,CT CA CA,CT,XN,XH CA,CT,XN,XH XN,XH,CA,CT CA,CT - 208 XH,XN XH,CA,CT,XN XH,CA,CT,XN CA CA,CT,XN,XH CA CA CA,CT CA,CT CA CA RN,RH 220 CA RN,RH 230 RN,RH RN,RH RN,RH - 240 XH,XN XH,CA,CT,MR,XN XH,CA,CT,MR,XN CA,CT CA,CT,XN,XH,MR CA,CT,RN,RH CA RN,RH,CA,CT,XN,XH RN,RH,CA,CT RN,RH,CA,CT CA,CT - 277 XH,XN XH,CA,XN CA,XH,XN XN,XH,CA XN,XH,CA CA,RN CA CA,CT CA,CT CA CA - 480 DT1 XH,XN MR XH,XN,CA,CT,MR CA CA,CT,XH,MR,XN CT CT CA,MR XN,XH,CA,CT,MR CA,CT CT, CA CA CA CA,CT CA,CT,XN,XH CA,CT XN,XH,CA,CT CA,CT CA,CT CA,CT CA,CT - DT2 XH,XN XH,XN,CA,CT,MR CA,CT,MR,XH,XN CT,CA XN,XH,CA,CT, MR CT,CA CA CA,CT,XN,XH XN,XH,CA,CT CA,CT CA,CT - DT3 MR CT MR CT CT CT - DT4 MR CT MR CT CT CT - Roadway 115 continued Watts 03S 05S 07S 10S 10V 15S 13S 14S 17V 17M 20S 25S 25V 25M 40S MT1 XH,XN XH,XN,CA CA,XN,XH CA XN,XH,CA CA CA CA,CT CA,CT CA CA - MT2 XN,XH XH,XN,CA, CA,XN,XH CA XN,XH,CA CA CA CA,CT CA,CT CA CA - MT7 XN,XH XH,XN,CA, CA,XN,XH CA XN,XH,CA CA CA CA,CT CA,CT CA CA - MT8 XN,XH XH,XN,CA CA,XN,XH CA XN,XH,CA CA CA CA,CT CA,CT CA CA - TT1 XN,XH XN,XH XN,XH XN,XH CA CA,CT CA - TT3 347 XN,XH XN,XH,CA,CT XN,XH XN,XH XN,XH XN,XH XN,XH XN,XH,CA CA CA CA,CT CA,CT CA CA CA - See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 55 Roadway Lighting B A L L A S T M AT R I C E S Roadway 315 Watts 03S 05S 07S 10S 10V 15S 13S 14S 17V 17M 20S 25S 25V 25M 40S 120 RN,RH RH,RN RH,CA,CT,RN,MR CA,CT,MR,RH,RN XH,XN,CA,CT RH,CA,CT,MR,RN RN,RH RN,RH XN,XH,CA,CT CA XH,CA,CT,XN XH,CA,CT,XN XN,XH,CA,CT CA,CT XH,XN,CA 208 XH,XN XH,CA,CT,XN XH,CA,CT,XN CA XH,CA,CT,XN CA CA CA,CT CA,CT CA CA CA 220 CA RH,CA 230 RN,RH RN,RH RN,RH - 240 XH,XN XH,CA,CT,MR,XN XH,CA,CT,MR,XN CA,CT XH,CA,CT,MR,XN RH,RN,CA,CT CA XH,RH,CA,CT,RN,XN RH,CA,CT,RN RH,RN,CA,CT CA,CT RH,RN,CA 277 XH,XN XH,CA,XN CA,XH,XN CA,XN,XH XH,CA,XN CA,RN CA CA,CT CA,CT CA CA - 480 MR CA CT CA CA,CT CA CA,CT CA,CT CA,CT CA,CT CA DT1 XH,XN XH,XN,CA,CT,MR CA,CT,XH,MR,XN CT XH,XN,CA,CT,MR CA,CT CA XH,XN,CA,CT XH,XN,CA,CT CA,CT CA,CT - DT2 XH,XN XH,XN,CA,CT,MR CA,CT,MR,XH,XN CA,CT XH,XN,CA,CT,MR CA,CT CA XH,,XN,CA,CT XN,XH,CA,CT CA,CT CA,CT - DT3 MR CT MR CT CT CT - Roadway 315 continued Watts 03S 05S 07S 10S 10V 15S 13S 14S 17V 17M 20S 25S 25V 25M 40S DT4 MR CT MR CT CT CT - MT1 XH,XN XH,XN,CA CA,XN,XH CA XN,XH,CA CA CA CA,CT CA,CT CA CA CA,XN,XH MT2 XN,XH XH,XN,CA CA, XN,XH CA XN,XH,CA CA CA CA,CT CA,CT CA CA CA,XN,XH MT7 XN,XH XH,XN,CA CA,XN,XH CA XN,XH,CA CA CA CA,CT CA,CT CA CA CA,XN,XH MT8 XN,XH XH,XN,CA CA,XN,XH CA XN,XH,CA CA CA CA,CT CA,CT CA CA CA,XN,XH TT1 XN,XH XN,XH XN,XH XN,XH CA CA,CT CA - TT3 XN,XH XN,XH XN,XH XN,XH CA CA,CT CA - 347 XN,XH,CA,CT XN,XH XN,XH XN,XH,CA CA CA,CT CA CA - Roadway 125 Watts 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 23/24M 120 XN,XH,CA,CT CA CA, CT, XN, XH MR XH,XN,CA,CT,MR CT,CA,XN,XH CA,CT,SC CA,MR CA,CT,XN,XH,MR CA,CT,XN,XH CA,CT,SC CA,CT, CA 208 CA CA CA, CT CA,CT CA CA,CT,SC CA CA,CT CA,CT CA,CT,SC CA,CT, CA 220 CA RN,RH CA CA RN,RH CA CA - 230 RN,RH RN,RH RN,RH - MT2 CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA MT7 CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA MT8 CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA 240 277 CA,CT,RN,RH CA,RN CA CA CA,CT,RN,RH,MR CA,CT,MR RN,RH,CA,CT,MR CA,CT RH.RN,CA,CT CA CA,CT,SC CA,SC CA,MR CA RH,RN,CA,CT,MR CA,CT CA,CT,XN,XH CA,CT CA,CT,SC CA,SC CA,CT CA,CT CA CA 480 DT1 DT2 CA,CT CT, CA CT,CA CA CA CA CA,CT,MR XN,XH,CA,CT,MRXN,XH,CA,CT,MR CA,MR XN,XH,MR XN,XH,MR CA,CT CA,CT CA,CT CA,CT CA,CT,SC CA,CT,SC CA,MR CA,MR CA,MR CA,MR CA,CT,MR,XN,XHCA,CT,MR,XN,XH CT,CA CA,CT,XN,XH CA,CT,XN,XH CA,CT, CA,CT CA,CT CA CA,CT CA,CT CA CA CA Roadway 125 continued Watts 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 23/24M 56 MT1 CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA Product Guide TT1 CA CA CA CA CA CA - TT7 CA CA CA CA CA CA - TT3 CA CA CA CA CA CA - For photometric information, visit our website, www.americanelectriclighting.com 347 CA CA CA CA CA CA CA - DT3 CT MR MR CT CT MR MR CT CT - DT4 CT MR MR CT CT MR MR CT CT - Roadway Lighting B A L L A S T M AT R I C E S Roadway 325 Watts 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 23/24M 120 XN,XH,CA,CT CA CA, CT, XN, XH MR XH,XN,CA,CT,MR CT,CA,XN,XH CA,CT,SC CA,MR CA,CT,XN,XH,MR CA,CT,XN,XH CA,CT,SC CA,CT, CA 208 CA CA CA, CT CA,CT CA CA,CT,SC CA CA,CT CA,CT CA,CT,SC CA,CT, CA 220 CA RN,RH CA CA RN,RH CA CA - 230 RN,RH RN,RH RN,RH - 240 CA,CT,RN,RH CA CA,CT,RN,RH,MR RN,RH,CA,CT,MR RH.RN,CA,CT CA,CT,SC CA,MR RH,RN,CA,CT,MR CA,CT,XN,XH CA,CT,SC CA,CT CA 277 CA,RN CA CA,CT,MR CA,CT CA CA,SC CA CA,CT CA,CT CA,SC CA,CT CA 480 CA,CT CA CA,CT,MR CA,MR CA,CT CA,CT CA,MR CA,MR CT,CA CA,CT, CA CA DT1 CT, CA CA XN,XH,CA,CT,MR XN,XH,MR CA,CT CA,CT,SC CA,MR CA,CT,MR,XN,XH CA,CT,XN,XH CA,CT CA,CT CA DT2 CT,CA CA XN,XH,CA,CT,MR XN,XH,MR CA,CT CA,CT,SC CA,MR CA,CT,MR,XN,XH CA,CT,XN,XH CA,CT CA,CT CA DT3 CT MR MR CT CT MR MR CT CT - DT4 CT MR MR CT CT MR MR CT CT - Roadway 325 continued Watts 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 23/24M MT1 CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA MT2 CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA MT7 CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA MT8 CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA TT1 CA CA CA CA CA CA - TT7 CA CA CA CA CA CA - TT3 CA CA CA CA CA CA - 347 CA CA CA CA CA CA CA - Roadway 327 Watts 31S 40S 40V 40M 75S 75M XS XV XM 120 CA CA,CT,XN,XH,MR CA,CT,XN,XH CA,CT,SC CA SC CA,CT CA CA,SC 208 CA CA,CT CA,CT CA,CT,SC CA SC CA,CT CA CS,SC 220 RN5,RH5 CA5 CA5 230 CA 5H - 240 CA RH,RN,CA,CT,MR CA,CT,XN,XH CA,CT,SC CA SC CA,CT CA CA,SC 277 CA CA,CT CA,CT CA,SC XX SC CA,CT CA CA,SC 480 CA CA,MR CT,CA CA,CT, SC CA,CT CA CA,SC DT1 CA CA,CT,,XN,XH,MR CA,CT,XN,XH CA,CT CA SC CA,CT CA CA,SC DT2 CA CA,CT,,XN,XH,MR CA,CT,XN,XH CA,CT CA SC CA,CT CA CA,SC DT3 MR CT CT - DT4 MR CT CT - MT1 CA CA,CT CA CA,SC SC CA CA CA,SC Roadway 327 continued Watts 31S 40S 40V 40M 75S 75M XS XV XM MT2 CA CA,CT CA CA,SC SC CA CA CA,SC MT7 CA CA,CT CA CA,SC SC CA CA CA,SC MT8 CA CA,CT CA CA,SC SC CA CA CA,SC TT1 CA CA CA SC CA CA,SC TT7 CA CA CA SC CA CA,SC TT3 CA CA CA SC CA CA,SC 347 CA CA CA SC CA CA,SC See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 57 Roadway Lighting B A L L A S T M AT R I C E S Roadway 413 Watts 03S 05S 07S 10S 15S 120 RH,RN RH,RN RH,RN RH,RN RH,RN 240 RH,RN RH RH,RN Multi-Mount™ 285 Watts 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 120 XH,CA,CT,MR,XN XN,CA,CT,MR,XH XH,XN, CA CA MR XN,CA,CT,MR,XH XH,XN, CA CA CA 208 CA,CT CA,CT CA CA CA,CT CA CA CA 240 RN,RH,CA,CT, MR RH,RN,CA,CT, MR RH.RN CA MR RH.RN,CA,CT, MR CA CA CA 277 CA,CT CA,CT CA CA CA,CT CA CA CA 480 DT1 DT2 CA,CT,MRXH,XN,CA,CT,MR XH,XN,CA,CT,MR CA,CT,MRXH,XN,CA,CT,MR XH,XN,CA,CT,MR CA CA CA CA CA MR MR MR CA,CT,MR CA,CT,MR CA,CT,MR CA CA CA CA CA CA CA CA DT3 MR MR CA MR MR CA - 230 RN,RH RN,RH RN,RH - 480 CA,CT CA CA,CT,MR CA, CA,CT CA,CT CA, CA, CT,CA CA,CT, CA CA DT4 MR MR CA MR MR CA - MT1 CA,CT CA,CT CA CA CA,CT CA CA CA MT2 CA,CT CA,CT CA CA CA,CT CA CA CA Multi-Mount™ 285 continued Watts 20S 25S 25V 25M 31S 40S 40V 40M 23/24S MT7 CA,CT CA,CT CA CA CA,CT CA CA CA MT8 CA,CT CA,CT CA CA CA,CT CA CA CA TT1 CA CA CA CA - TT7 CA CA CA CA - TT3 CA CA CA CA - 347 CA CA CA CA - Interstate™ II 775 Watts 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 23/24M 120 XN,XH,CA,CT CA CA, CT, XN, XH ,MR XH,XN,CA,CT, CT,CA,XN,XH CA,CT,SC CA,MR CA,CT,XN,XH, CA,CT,XN,XH CA,CT,SC CA,CT, CA 208 CA CA CA, CT CA,CT CA CA,CT,SC CA CA,CT CA,CT CA,CT,SC CA,CT, CA 220 RN,CA CA,RN,RH CA CA RN,RH CA - 240 CA,CT,RN,RH CA CA,CT,RN,RH,MR RN,RH,CA,CT, RH.RN,CA,CT CA,CT,SC CA,MR RH,RN,CA,CT, CA,CT,XN,XH CA,CT,SC CA,CT CA 277 CA,RN CA CA,CT, CA,CT CA CA,SC CA CA,CT CA,CT CA,SC CA,CT CA Interstate™ II 775 continued Watts 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 23/24M 58 DT3 CT MR CT CT CT CT - Product Guide DT4 CT MR CT CT CT CT - MT1 CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA MT2 CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA MT7 CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA MT8 CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA TT1 CA CA CA CA CA CA - TT7 CA CA CA CA CA CA - TT3 CA CA CA CA CA CA - 347 CA CA CA CA CA CA CA - For photometric information, visit our website, www.americanelectriclighting.com DT1 CT, CA CA XN,XH,CA,CT, MR XN,XH,MR CA,CT CA,CT,SC CA, CA,CT,,XN,XH CA,CT,XN,XH CA,CT CA,CT CA DT2 CT,CA CA XN,XH,CA,CT,MR XN,XH, CA,CT CA,CT,SC CA CA,CT,,XN,XH CA,CT,XN,XH CA,CT CA,CT CA Roadway Lighting B A L L A S T M AT R I C E S LPS Roadway SRP Watts 13L 18L 09L 120 XH XH XH 208 XH XH XH 240 XH XH XH 277 XH XH XH 347 XH XH XH 480 XH XH RH 208 XH XH XH 240 XH XH XH 277 XH XH XH 347 XH XH XH 480 RH RH RH 208 XH XH XH 240 XH XH XH 277 XH XH XH 347 XH XH XH 480 RH,XH XH XH DT1 XH XH XH DT2 XH XH XH DT5 XH XH XH DT6 XH XH XH LPS Roadway SRX Watts 03L 55L 09L 120 XH XH XH DT1 XH XH XH DT2 XH XH XH DT5 XH XH XH DT6 XH XH XH LPS Roadway SP2 Watts 13L 18L 09L 120 XH XH XH DT1 XH XH XH DT2 XH XH XH DT5 XH XH XH DT6 XH XH XH UnderPass Series 581/681 Watts 05S 07S 10S 10V 15S 17V 17M 20S 25S 25V 25M 120 RN RN, RH, CA, CT, MR RN, RH, CA, CT XN, XH, CT RN, RH, CA, MR XN, XH, CA, CT CA XN, XH XN, XH CA CA 208 XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA CA CA CA CA 240 XN, XH, CA, CT, MR XN, XH, CA, CT CT XN, XH, CA, MR RN, RH, CA, CT CA XN, XH XN, XH CA CA 277 XN, XH, CA XN, XH, CA, CT XN, XH, CA RN, RH, CA CA CA CA 480 CA, MR CA CA, MR CA CA - DT1 XN, XH, CA, CT, MR CA, CT CT CA, MR CA , CT CA XN, XH XN, XH CA CA DT2 XN, XH, CA, CT, MR CA, CT CT CA, MR CA, CT CA XN, XH XN, XH CA CA DT3 MR MR - UnderPass Series 581/681 continued Watts 05S 07S 10S 10V 15S 17V 17M 20S 25S 25V 25M DT4 MR MR - MT1 CA CA, CT CA CA CA CA CA MT2 CA CA, CT CA CA CA CA CA MT7 CA CA, CT CA CA CA CA CA MT8 CA CA, CT CA CA CA CA CA TT1 XN, XH XN, XH XN, XH CA CA - TT3 XN, XH XN, XH XN, XH CA CA - See pages 259-264 for a complete listing of Frequently Ordered Products TT7 XN, XH XN, XH XN, XH CA CA - 347 XN, XH, CT XN, XH, CT XN, XH CA CA - Product Guide 59 Roadway Lighting B A L L A S T M AT R I C E S Heavy-Duty Wallpack 882 Watts 25S 25M 40S 40M MT1 CA,CT CA,CT CA,CT CA,CT MT2 CA,CT CA,CT CA,CT CA,CT MT7 CA,CT CA,CT CA,CT CA,CT MT8 CA,CT CA,CT CA,CT CA,CT TT1 CA,CT CA,CT CA,CT CA,CT TT7 CA,CT CA,CT CA,CT CA,CT TT3 CA,CT CA,CT CA,CT CA,CT 480 CA,CT - Signlite 875 Watts 10S 10V 15S 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 23/24M 120 CA,CT,MR,RH,RN XH,XN,CA,CT RN,RH,CA,CT,MR XN,XH,CA,CT CA CA, CT, XN, XH ,MR XH,XN,CA,CT, CT,CA,XN,XH CA,CT,SC CA,MR CA,CT,XN,XH, CA,CT,XN,XH CA,CT,SC CA,CT, CA 208 XH,CA,CT,XN CA CA,CT,XN,XH CA CA CA, CT CA,CT CA CA,CT,SC CA CA,CT CA,CT CA,CT,SC CA,CT, CA 220 RN,CA CA,RN,RH CA CA RN,RH CA - 230 RN,RH RN,RH RN,RH RN,RH - 240 XH,CA,CT,MR,XN CA,CT CA,CT,XN,XH,MR CA,CT,RN,RH CA CA,CT,RN,RH,MR RN,RH,CA,CT, RH.RN,CA,CT CA,CT,SC CA,MR RH,RN,CA,CT, CA,CT,XN,XH CA,CT,SC CA,CT CA 277 CA,XH,XN,CT XN,XH,CA XN,XH,CA CA,RN CA CA,CT, CA,CT CA CA,SC CA CA,CT CA,CT CA,SC CA,CT CA 480 CA CT CA,MR CA,CT CA CA,CT,MR CA, CA,CT CA,CT CA CA, CT,CA CA,CT, CA CA DT1 CA,CT,XH,MR,XN CT XN,XH,CA,CT,MR CT, CA CA XN,XH,CA,CT, MR XN,XH,MR CA,CT CA,CT,SC CA CA,CT,,XN,XH CA,CT,XN,XH CA,CT CA,CT CA DT2 CA,CT,MR,XH,XN CT,CA XN,XH,CA,CT, MR CT,CA CA XN,XH,CA,CT,MR XN,XH CA,CT CA,CT,SC CA CA,CT,,XN,XH CA,CT,XN,XH CA,CT CA,CT CA Signlite 875 continued Watts 10S 10V 15S 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 23/24M 60 DT3 CT MR CT MR CT CT CT CT - Product Guide DT4 CT MR CT MR CT CT CT CT - MT1 CA,XN,XH,CT CA XN,XH,CA,CT CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA MT2 CA,XN,XH,CT CA XN,XH,CA,CT CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA MT7 CA,XN,XH,CT CA XN,XH,CA,CT CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA MT8 CA,XN,XH,CT CA XN,XH,CA,CT CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA TT1 XN,XH XN,XH XN,XH CA CA CA CA CA CA - For photometric information, visit our website, www.americanelectriclighting.com TT7 XN,XH XN,XH XN,XH CA CA CA CA CA CA - TT3 XN,XH XN,XH XN,XH CA CA CA CA CA CA - 347 XN,XH XN,XH XN,XH,CA CA CA CA CA CA CA CA - DECORATIVE & POST-TOP LIGHTING Heritage Collection ..................................................62 Heritage Poles ........................................................100 Marietta Series ....................................................62 Chadsworth Series............................................100 Sumter Series ......................................................64 New Albany Series ...........................................102 Cresthill Classic ...................................................66 Statesboro Series..............................................104 Cresthill Sphere ...................................................68 Waycross Series ...............................................106 Cresthill Centennial .............................................70 Accessories........................................................108 Cresthill Glass ......................................................72 Ballast Matrices .....................................................132 Lexington...............................................................74 Syracuse Series ..................................................76 Victorian Series ...................................................78 Yorktown ...............................................................80 Branson.................................................................82 Depot .....................................................................84 American Revolution Series 247............................86 American Revolution Cutoff Series 247 ................88 Contempo Series 245 ..............................................90 Residential Post Top Series RES............................92 TwistPackTM Series TWT.........................................94 Bainbridge Series 870 .............................................96 Georgian Series GRP ...............................................98 American Electric Lighting™ Heritage Collection Marietta Series 35-250W HPS, 50-250W MH, 100-250W MV PP RR O OD DU U CC TT O O VV EE RR VV II EE W W Features: NEW Available in solid or clear top prismatic globe. Interchangeable base with a wide variety of globes. Symmetric or Asymmetric distribution. Available in Semi-Cutoff IES classification. Injection-molded, high-impact acrylic or polycarbonate. Excellent uniformity, light distribution and efficiency. Maximizes pole spacing. Base and optical ship separately. HPS units standard with encapsulated starter that is located at the socket for quick access. Quick disconnect plug for easy maintenance. Easy access component door. Applications: Photocontrol and terminal block available and located with easy access from component door. Streetscapes Walkways Pathways Parks Uplight shield option available. E39 mogul base socket standard. Mounts to 3” x 3” pole top tenons. All electrical components warranted by AEL’s 6-year guarantee. DIMENSIONS Complies with ANSI: C136.2, C136.10, C136.15, C136.31. 15.9" (404) Suitable for -30°C MH & MV / -40°C HPS. 36" (914) 9.13" (232) Effective Projected Area (EPA) The EPA for the Marietta Series is 2.7 sq. ft. Approx. Wt. = 24 lbs. 62 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Heritage Collection Marietta Series 35-250W HPS, 50-250W MH, 100-250W MV O R D E R I N G I N F O R M AT I O N Example: L M D 1 7 M C A M T 1 R 5 P A P R P C U S Wattage / Source Series LMD Marietta 03 05 07 10 15 17 25 S M V 35W 50W 70W 100W 150W 175W 250W1 HPS MH MV RN RH XN XH CA CT Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 132 for compatibility. Distribution Voltage Ballast 120 208 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 DT2 120V 208V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120 Tri-tap wired 277 Tri-tap wired 347 Dual Tap 120/240 wired 120 Dual Tap 120/240 wired 240 R3 Type III R5 Type V Options Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Globe PP PA PP PN Prismatic Polycarbonate solid top (optical) Prismatic Acrylic solid top (optical) Prismatic clear top polycarbonate (optical) Prismatic clear top acrylic (optical) Paint (blank) Black VG Verde Green BZ Bronze Receptacle (blank) No photocontrol receptacle (std) PR Photocontrol receptacle PB Phosphor bronze contacts2 Terminal Block (blank) Terminal Block (std) T2 Wired to L1 & L2 Positions T3 3 wire operations (L1, N, L2 Position) Lamp LC LD Notes: 1 250W adds 3” to housing height 2 For use with PR option Lamp Included, Clear Lamp Included, Deluxe/Coated Photocontrol (blank) None PC Twist-lock Photocontrol2 Misc SH SS US BD TL Shorting Cap2 Stainless Steel Fasteners (external) Uplight Shield Without decorative cage Tool-less Entry See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 63 Heritage Collection Sumter Series 35-250W HPS, 50-250W MH, 100-250W MV P R O D U C T O V E R V I E W Features: NEW Solid top prismatic globe. Interchangeable base with a wide variety of globes. Symmetric or Asymmetric distribution. Available in Semi-Cutoff IES classification. Injection-molded, high-impact acrylic or polycarbonate. Excellent uniformity, light distribution and efficiency. Maximizes pole spacing. Base and optical ship separately. HPS units standard with encapsulated starter that is located at the socket for quick access. Quick disconnect plug for easy maintenance. Easy access component door. Photocontrol and terminal block available and located with easy access from component door. Applications: Streetscapes Walkways Pathways Parks E39 mogul base socket standard. Mounts to 3” x 3” pole top tenons. All electrical components warranted by AEL’s 6-year guarantee. Complies with ANSI: C136.2, C136.10, C136.15, C136.31. DIMENSIONS Suitable for -30°C MH & MV / -40°C HPS. 15.66" (398) 39.25" (970) 3.25" (83) Effective Projected Area (EPA) The EPA for the Sumter Series is 2.7 sq. ft. Approx. Wt. = 24 lbs. 64 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Heritage Collection Sumter Series 35-250W HPS, 50-250W MH, 100-250W MV O R D E R I N G I N F O R M AT I O N Example: L S H 1 7 M C A 1 2 0 R 5 P A P R L C P C Wattage / Source Series LSH Sumter 03 05 07 10 15 17 25 S M V 35W 50W 70W 100W 150W 175W 250W1 HPS MH MV RN RH XN XH CA CT Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 132 for compatibility. Distribution Voltage Ballast 120 208 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 DT2 120V 208V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120 Tri-tap wired 277 Tri-tap wired 347 Dual Tap 120/240 wired 120 Dual Tap 120/240 wired 240 R3 Type III R5 Type V Options Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Globe PP PA Prismatic Polycarbonate (optical) Prismatic Acrylic (optical) Paint (blank) Black VG Verde Green BZ Bronze Receptacle (blank) No photocontrol receptacle (std) PR Photocontrol receptacle PB Phosphor Bronze Contacts2 Lamp LC LD Notes: Lamp Included, Clear Lamp Included, Deluxe/Coated Photocontrol (blank) None PC Twist-lock Photocontrol2 Misc SH SS TL 1 250W adds 3” to housing height 2 For use with PR option Shorting Cap2 Stainless Steel Fasteners (external) Tool-less Entry Terminal Block (blank) Terminal Block (std) T2 Wired to L1 & L2 Positions T3 3 wire operations (L1, N, L2 Position) See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 65 Heritage Collection Cresthill Classic 35-250W HPS, 50-250W MH, 100-250W MV P R O D U C T O V E R V I E W Features: Interchangeable base with a wide variety of globes. Symmetric or Asymmetric distribution. Globe available in stepped acrylic and polycarbonate or prismatic acrylic and polycarbonate. Base and optical ship separately. HPS units standard with encapsulated starter that is located at the socket for quick access. Quick disconnect plug for easy maintenance. Easy access component door. Photocontrol and terminal block available and located with easy access from component door. E39 mogul base socket standard. Mounts to 3” x 3” pole top tenons. Applications: All electrical components warranted by AEL’s 6-year guarantee. Streetscapes Walkways Pathways Parks Complies with ANSI: C136.2, C136.10, C136.15, C136.31. Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS 13" (330) 32" (813) 3.25" (83) Effective Projected Area (EPA) The EPA for the Cresthill Classic is 1.4 sq. ft. Approx. Wt. = 37 lbs. 66 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Heritage Collection Cresthill Classic 35-250W HPS, 50-250W MH, 100-250W MV O R D E R I N G I N F O R M AT I O N Example: L C R 1 0 S R N 1 2 0 R 5 A P P R L C P C Wattage / Source Series LCR Cresthill 03 05 07 10 15 17 25 S M V 35W 50W 70W 100W 150W 175W 250W1 Voltage Ballast HPS MH MV RN RH XN XH CA CT Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 133 for compatibility. 120 208 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 DT2 120V 208V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120 Tri-tap wired 277 Tri-tap wired 347 Dual Tap 120/240 wired 120 Dual Tap 120/240 wired 240 Distribution R0 No internal refractor R3 Type III2 R5 Type V2 Options Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Globe AP AA PN PT Classic Large Clear Polycarbonate (Non-optical) Classic Large Clear Acrylic (Non-optical) Prismatic Polycarbonate (optical) Prismatic Acrylic (optical) Paint (blank) Black VG Verde Green BZ Bronze Receptacle (blank) No photocontrol receptacle (std) PR Photocontrol receptacle PB Phosphor bronze contacts3 Terminal Block (blank) Terminal Block (std) T2 Wired to L1 & L2 Positions T3 3 wire operations (L1, N, L2 Position) Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Notes: 1 250W adds 3” to housing height 2 Achieved with internal glass refractor except with prismatic globes 3 For use with PR options 4 For use with PA and PP only Photocontrol (blank) None PC Twist-lock Photocontrol3 Misc SH SS US 9R TL Shorting Cap3 Stainless Steel Fasteners (external) Uplight Shield4 9" Globe neck Tool-less Entry See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 67 Heritage Collection Cresthill Sphere 35-250W HPS, 50-250W MH, 100-250W MV P R O D U C T O V E R V I E W Features: Interchangeable base with a wide variety of globes. Symmetric or Asymmetric distribution. Globe available in 22” white acrylic or clear polycarbonate. Base and optical ship separately. HPS units standard with encapsulated starter that is located at the socket for quick access. Quick disconnect plug for easy maintenance. Easy access component door. Photocontrol and terminal block available and located with easy access. from component door. E39 mogul base socket standard. Mounts to 3” x 3” pole top tenons. Powdercoat finish. Applications: All electrical components warranted by AEL’s 6-year guarantee. Streetscapes Walkways Pathways Parks Complies with ANSI: C136.2, C136.10, C136.15, C136.31. Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS 16" (22) 26" (660) 3.25" (83) Effective Projected Area (EPA) The EPA for the Cresthill Sphere is 2.5 sq. ft. Approx. Wt. = 22 lbs. 68 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Heritage Collection Cresthill Sphere 35-250W HPS, 50-250W MH, 100-250W MV O R D E R I N G I N F O R M AT I O N Example: L C R 1 0 S R N 1 2 0 R 5 S Y P R L C P C Wattage / Source Series LCR Cresthill 03 05 07 10 15 17 25 S M V 35W 50W 70W 100W 150W 175W 250W1 Voltage Ballast HPS MH MV RN RH XN XH CA CT Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 133 for compatibility. 120 208 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 DT2 120V 208V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120 Tri-tap wired 277 Tri-tap wired 347 Dual Tap 120/240 wired 120 Dual Tap 120/240 wired 240 Distribution R0 No internal retractor R3 Type III2 R5 Type V2 Options Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Globe SL SY Sphere Polycarbonate Sphere Acrylic Paint (blank) Black VG Verde Green BZ Bronze Receptacle (blank) No photocontrol receptacle (std) PR Photocontrol receptacle PB Phosphor bronze contacts3 Lamp LC LD Notes: Lamp Included, Clear Lamp Included, Deluxe/Coated Photocontrol (blank) None PC Twist-lock Photocontrol3 Misc SH SS 9R TL 1 250W adds 3” to housing height 2 Achieved with internal glass refractor 3 For use with PR options Shorting Cap3 Stainless Steel Fasteners (external) 9" Globe neck Tool-less Entry Terminal Block (blank) Terminal Block (std) T2 Wired to L1 & L2 Positions T3 3 wire operations (L1, N, L2 Position) See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 69 Heritage Collection Cresthill Centennial 35-250W HPS, 100-250W MH, 100-250W MV P R O D U C T O V E R V I E W Features: Interchangeable base with a wide variety of globes. Symmetric or Asymmetric distribution. Acrylic or polycarbonate globe. Base and optical ship separately. HPS units standard with encapsulated starter that is located at the socket. for quick access. Quick disconnect plug for easy maintenance. Easy access component door. Photocontrol and terminal block available and located with easy access from component door. E39 mogul base socket standard. Mounts to 3” x 3” pole top tenons. Powdercoat finish. Applications: All electrical components warranted by AEL’s 6-year guarantee. Streetscapes Walkways Pathways Parks Complies with ANSI: C136.2, C136.10, C136.15, C136.31. Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS 16" (406) 32" (813) 3.25" (83) Effective Projected Area (EPA) The EPA for the Cresthill Centennial is 1.2 sq. ft. Approx. Wt. = 22 lbs. 70 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Heritage Collection Cresthill Centennial 35-250W HPS, 100-250W MH, 100-250W MV O R D E R I N G I N F O R M AT I O N Example: L C R 1 0 S R N 1 2 0 R 5 C Y P R L C P C Wattage / Source Series LCR Cresthill 03 05 07 10 15 17 25 35W 50W 70W 100W 150W 175W 250W1 S M V Voltage Ballast HPS MH MV RN RH XN XH CA CT Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 133 for compatibility. 120 208 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 DT2 120V 208V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120 Tri-tap wired 277 Tri-tap wired 347 Dual Tap 120/240 wired 120 Dual Tap 120/240 wired 240 Distribution RO No internal retractor R3 Type III2 R5 Type V2 Options Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Globe CE CW CY CM Centennial Large Clear Acrylic (Non-optical) Centennial Large White Polycarbonate Centennial Large Clear Acrylic Centennial Medium Clear Acrylic Paint (blank) Black VG Verde Green BZ Bronze Receptacle (blank) No photocontrol receptacle (std) PR Photocontrol receptacle PB Phosphor bronze contacts3 Terminal Block (blank) Terminal Block (std) T2 Wired to L1 & L2 Positions T3 3 wire operations (L1, N, L2 Position) Lamp LC LD Notes: 1 250W adds 3” to cast housing height 2 Achieved with internal glass refractor 3 For use with PR options Lamp Included, Clear Lamp Included, Deluxe/Coated Photocontrol (blank) None PC Twist-lock Photocontrol3 Misc SH SS 9R TL Shorting Cap3 Stainless Steel Fasteners (external) 9" Globe neck Tool-less Entry See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 71 Heritage Collection Cresthill Glass 35-250W HPS, 50-250W MH, 100-250W MV P R O D U C T O V E R V I E W Features: NEW Interchangeable base with a wide variety of globes. Symmetric or Asymmetric distribution. Prismatic glass globe. Base and optical ship separately. HPS units standard with encapsulated starter that is located at the socket for quick access. Quick disconnect plug for easy maintenance. Easy access component door. Photocontrol and terminal block available and located with easy access from component door. E39 mogul base socket standard. Mounts to 3” x 3” pole top tenons. Powdercoat finish. Applications: All electrical components warranted by AEL’s 6-year guarantee. Streetscapes Walkways Pathways Parks Complies with ANSI: C136.2, C136.10, C136.15, C136.31. Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS 14" (355) 28.5" (724) 3.25" (83) Effective Projected Area (EPA) The EPA for the Cresthill Glass is 1.4 sq. ft. Approx. Wt. = 37 lbs. 72 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Heritage Collection Cresthill Glass 35-250W HPS, 50-250W MH, 100-250W MV O R D E R I N G I N F O R M AT I O N Example: L C R 1 0 S R N 1 2 0 R 5 P G P R L C P C Wattage / Source Series LCR Cresthill 03 05 07 10 15 17 25 S M V 35W 50W 70W 100W 150W 175W 250W1 Voltage Ballast HPS MH MV RN RH XN XH CA CT Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI 120 208 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 Refer to ballast matrix on page 133 for compatibility. DT2 120V 208V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120 Tri-tap wired 277 Tri-tap wired 347 Dual Tap 120/240 wired 120 Dual Tap 120/240 wired 240 Distribution R3 Type III R5 Type V Options Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Globe PG Prismatic Glass Paint (blank) Black VG Verde Green BZ Bronze Receptacle (blank) No photocontrol receptacle (std) PR Photocontrol receptacle PB Phosphor bronze contacts1 Lamp LC LD Notes: Lamp Included, Clear Lamp Included, Deluxe/Coated Photocontrol (blank) None PC Twist-lock Photocontrol2 Misc SH SS 9R TL 1 250 W adds 3” to cast housing height 2 For use with PR options Shorting Cap2 Stainless Steel Fasteners (external) 9" Globe neck Tool-less Entry Terminal Block (blank) Terminal Block (std) T2 Wired to L1 & L2 Positions T3 3 wire operations (L1, N, L2 Position) See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 73 Heritage Collection Lexington 35-250W HPS, 50-250W MH, 100-250W MV P R O D U C T O V E R V I E W Features: Available with or without spikes. Interchangeable base with a wide variety of lenses. Symmetric or Asymmetric distribution. Decorative spike finial standard. Rugged cast-aluminum housing. Lens available in acrylic, polycarbonate or clear glass. Base and optical ship separately. HPS units standard with encapsulated starter that is located at the socket for quick access. Quick disconnect plug for easy maintenance. Easy access component door. Photocontrol and terminal block available and located with easy access from component door. Applications: E39 mogul base socket standard. Streetscapes Walkways Pathways Parks Mounts to 3” x 3” pole top tenons. All electrical components warranted by AEL’s 6-year guarantee. Complies with ANSI: C136.2, C136.10, C136.15, C136.31. Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS 18.5" (470) 44" (1118) 3.25" (83) Effective Projected Area (EPA) The EPA for the lexington is 3.1 sq. ft. Approx. Wt. = 33 lbs. 74 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Heritage Collection Lexington 35-250W HPS, 50-250W MH, 100-250W MV O R D E R I N G I N F O R M AT I O N Example: L L X 1 0 S R N 1 2 0 R 5 A Y P R L C P C Series LLX Lexington Wattage / Source 03 05 07 10 15 17 25 S M V 35W 50W 70W 100W 150W 175W 250W1 Voltage Ballast HPS MH MV RN RH XN XH CA CT 120 208 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 133 for compatibility. DT2 120V 208V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120 Tri-tap wired 277 Tri-tap wired 347 Dual Tap 120/240 wired 120 Dual Tap 120/240 wired 240 Distribution R3 Type III R5 Type V Options Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Globe AY PY GL Acrylic Polycarbonate Glass Paint (blank) Black VG Verde Green BZ Bronze Receptacle (blank) No photocontrol receptacle (std) PR Photocontrol receptacle PB Phosphor Bronze Contacts2 Lamp LC LD Notes: Lamp Included, Clear Lamp Included, Deluxe/Coated Photocontrol (blank) None PC Twist-lock Photocontrol2 Misc SH SS NS TL 1 250 W adds 3” to cast housing height 2 For use with PR option Shorting Cap2 Stainless Steel Fasteners (external) No spikes on LLX housing Tool-less Entry Terminal Block (blank) Terminal Block (std) T2 Wired to L1 & L2 Positions T3 3 wire operations (L1, N, L2 Position) See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 75 Heritage Collection Syracuse Series 35-250W HPS, 50-250W MH, 100-250W MV P R O D U C T O V E R V I E W Features: Attractive cast-aluminum decorative cage. Interchangeable base with a wide variety of globes. Symmetric or Asymmetric distribution. Available in solid top prismatic acrylic or polycarbonate, and stippled acrylic or polycarbonate. Powdercoat finish. HPS units standard with encapsulated starter that is located at the socket for quick access. Quick disconnect plug for easy maintenance. Easy access component door. Photocontrol and terminal block available and located with easy access from component door. E39 mogul base socket standard. Applications: Mounts to 3” x 3” pole top tenons . Streetscapes Walkways Pathways Parks All electrical components warranted by AEL’s 6-year guarantee. Complies with ANSI: C136.2, C136.10, C136.15, C136.31. Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS 16" (406) 34" (864) 3.25" (83) Effective Projected Area (EPA) The EPA for the Syracuse Series is 1.5 sq. ft. Approx. Wt.. = 26 lbs. 76 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Heritage Collection Syracuse Series 35-250W HPS, 50-250W MH, 100-250W MV O R D E R I N G I N F O R M AT I O N Example: L S Y O 7 S R H 1 2 0 R 3 A Y L C Wattage / Source Series LSY Syracuse 03 05 07 10 15 17 25 S M V 35W 50W 70W 100W 150W 175W 250W1 HPS MH MV RN RH XN XH CA CT Distribution Voltage Ballast 120 208 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 134 for compatibility. DT2 120V 208V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120 Tri-tap wired 277 Tri-tap wired 347 Dual Tap 120/240 wired 120 Dual Tap 120/240 wired 240 RO No internal retractor R3 Type III2 R5 Type V2 Options Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Globe LSY Series AY Acrylic PY Polycarbonate PA Solid top prismatic acrylic PP Solid top prismatic polycarbonate Paint (blank) Black VG Verde Green BZ Bronze Receptacle (blank) No photocontrol receptacle (std) PR Photocontrol receptacle PB Phosphor Bronze Contacts3 Terminal Block (blank) Terminal Block (std) T2 Wired to L1 & L2 Positions T3 3 wire operations (L1, N, L2 Position) Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Notes: 1 250 W adds 3” to cast housing height 2 Achieved with internal glass refractor except with prismatic globes 3 For use with PR option Photocontrol (blank) None PC Twist-lock Photocontrol3 Misc SH SS TL Shorting Cap3 Stainless Steel Fasteners (external) Tool-less Entry See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 77 Heritage Collection Victorian Series 35-250W HPS, 50-250W MH, 100-250W MV P R O D U C T O V E R V I E W Features: Symmetric or Asymmetric distribution. Ships as a single unit. Powdercoat finish. Globe available in acrylic and polycarbonate. Interchangeable base with a wide variety of globes. HPS units standard with encapsulated starter that is located at the socket for quick access. Quick disconnect plug for easy maintenance. Easy access component door. Photocontrol and terminal block available and located with easy access from component door. E39 mogul base socket standard. Mounts to 3” x 3” pole top tenons. Applications: All electrical components warranted by AEL’s 6-year guarantee. Streetscapes Walkways Pathways Parks Complies with ANSI: C136.2, C136.10, C136.15, C136.31. Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS 15" (381) 48" (1219) 3.25" (83) Effective Projected Area (EPA) The EPA for the Victorian Series is 2.2 sq. ft. Approx Wt. = 40 lbs. 78 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Heritage Collection Victorian Series 35-250W HPS, 50-250W MH, 100-250W MV O R D E R I N G I N F O R M AT I O N Example: L V I 1 0 S R N 1 2 0 R 3 A Y Wattage / Source Series LVI Victorian 03 05 07 10 15 17 S M V 35W 50W 70W 100W 150W 175W HPS MH MV RN RH XN XH CA CT Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 134 for compatibility. Distribution Voltage Ballast 120 208 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 DT2 120V 208V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120 Tri-tap wired 277 Tri-tap wired 347 Dual Tap 120/240 wired 120 Dual Tap 120/240 wired 240 RO No internal refractor R3 Type III1 R5 Type V1 Options Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Globe AY PY Acrylic Polycarbonate Paint (blank) Black VG Verde Green BZ Bronze Receptacle (blank) No photocontrol receptacle (std) PR Photocontrol receptacle PB Phosphor Bronze Contacts2 Lamp LC LD Notes: Lamp Included, Clear Lamp Included, Deluxe/Coated Photocontrol (blank) None PC Twist-lock Photocontrol2 Misc SH SS TL 1 Achieved with internal glass refractor 2 For use with PR option Shorting Cap2 Stainless Steel Fasteners (external) Tool-less Entry Terminal Block (blank) Terminal Block (std) T2 Wired to L1 & L2 Positions T3 3 wire operations (L1, N, L2 Position) See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 79 Heritage Collection Yorktown 35-250W HPS, 50-250W MH, 100-250W MV P R O D U C T O V E R V I E W Features: Symmetric or Asymmetric distribution. Available in semi-cutoff IES classification. Rugged cast-aluminum housing. Button photocontrol available. Ships as single unit. Lens available in clear acrylic or polycarbonate. E39 mogul base socket standard. Powdercoat finish. All electrical components warranted by AEL’s 6-year guarantee. Complies with ANSI: C136.2, C136.10, C136.15, C136.31. Suitable for -30°C MH & MV / -40°C HPS. Applications: Streetscapes Walkways Pathways Parks DIMENSIONS 20" (508) 39" (991) 3.25" (83) Effective Projected Area (EPA) The EPA for the Yorktown is 2.8 sq. ft. Approx. Wt. = 42 lbs. 80 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Heritage Collection Yorktown 35-250W HPS, 50-250W MH, 100-250W MV O R D E R I N G I N F O R M AT I O N Example: L Y T 1 0 S R N 1 2 0 R 3 A Y L C Series LYT Yorktown Wattage / Source 03 05 07 10 15 17 25 35W 50W 70W 100W 150W 175W 250W1 S M V Voltage Ballast HPS MH MV RN RH XN XH CA CT 120 208 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 135 for compatibility. DT2 120V 208V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120 Tri-tap wired 277 Tri-tap wired 347 Dual Tap 120/240 wired 120 Dual Tap 120/240 wired 240 Distribution RO No internal retractor R3 Type III2 R5 Type V2 Options Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Globe AY PY Acrylic Polycarbonate Paint (blank) Black VG Verde Green BZ Bronze Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Photocontrol (blank) None BC Button Photocontrol Misc SS TL Notes: 1 250 W adds 3” to cast housing height 2 Achieved with internal glass refractor Stainless Steel Fasteners (external) Tool-less Entry See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 81 Heritage Collection Branson 35-250W HPS, 50-250W MH, 100-250W MV P R O D U C T O V E R V I E W Features: Ornamental aluminum canopy top. Interchangeable base with a wide variety of globes. Symmetric or Asymmetric distribution. Base and optical ship separately. Powdercoat finish. Base and optical ship separately. HPS units standard with encapsulated starter that is located at the socket for quick access. Quick disconnect plug for easy maintenance. Easy access component door. Photocontrol and terminal block available and located with easy access from component door. E39 mogul base lamp holder standard. Applications: Mounts to 3” x 3” pole top tenons. Streetscapes Walkways Pathways Parks Available in stippled acrylic or polycarbonate globes. All electrical components warranted by AEL’s 6-year guarantee. Complies with ANSI: C136.2, C136.10, C136.15, C136.31. Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS 13" (330) 38" (965) 3.25" (83) Effective Projected Area (EPA) The EPA for the Branson is 2.3 sq. ft. Approx. Wt. = 22 lbs. 82 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Heritage Collection Branson 35-250W HPS, 50-250W MH, 100-250W MV O R D E R I N G I N F O R M AT I O N Example: L B R 1 5 S C A M T 1 R 5 P Y L C Series LBR Branson Wattage / Source 03 05 07 10 15 17 25 35W 50W 70W 100W 150W 175W 250W1 S M V Voltage Ballast HPS MH MV RN RH XN XH CA CT 120 208 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 135 for compatibility. DT2 120V 208V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120 Tri-tap wired 277 Tri-tap wired 347 Dual Tap 120/240 wired 120 Dual Tap 120/240 wired 240 Distribution R3 Type III2 R5 Type V2 Options Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Globe LBR Series AY Acrylic PY Polycarbonate Terminal Block (blank) Terminal Block (std) T2 Wired to L1 & L2 Positions T3 3 wire operations (L1, N, L2 Position) Paint (blank) Black VG Verde Green BZ Bronze Lamp LC LD Receptacle (blank) No photocontrol receptacle (std) PR Photocontrol receptacle PB Phosphor Bronze Contacts3 Notes: 1 250 W adds 3” to cast housing height 2 Achieved with internal glass refractor 3 For use with PR option Lamp Included, Clear Lamp Included, Deluxe/Coated Photocontrol (blank) None PC Twist-lock Photocontrol3 Misc SH SS TL Shorting Cap3 Stainless Steel Fasteners (external) Tool-less Entry See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 83 Heritage Collection Depot 35-250W HPS, 50-250W MH, 100-250W MV PP RR OO DD UU CC TT OO VV EE RR VV I I EE W W Features: Suspended mount fixture. Powdercoat finish. Button photocontrol. Symmetric distribution. Arm ordered separately. Base, globe, and reflector ship separately. IES Cutoff classification. E39 mogul base socket standard. All electrical components warranted by AEL’s 6-year guarantee. Complies with ANSI: C136.2, C136.10, C136.15, C136.31. Suitable for -30°C MH & MV / -40°C HPS. Applications: Streetscapes Walkways Pathways Parks DIMENSIONS 25" (635) 49" (1245) 32" (813) Effective Projected Area (EPA) The EPA for the Depot is 3.7 sq. ft. Approx. Wt. = 28 lbs. Arm ordered separately 84 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Heritage Collection Depot 35-250W HPS, 50-250W MH, 100-250W MV N GG II N N FF OO RR M M AA TT II OO N N OO RR DD EE RR II N Example: L D P 1 5 S C A 1 2 0 R 5 A Y B C LDP Depot Ballast Wattage / Source Series 03 05 07 10 15 17 25 35W 50W 70W 100W 150W 175W 250W S M V HPS MH MV RN RH XN XH CA CT Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 135 for compatibility. Voltage 120 208 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 DT2 120V 208V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120 Tri-tap wired 277 Tri-tap wired 347 Dual Tap 120/240 wired 120 Dual Tap 120/240 wired 240 Distribution R3 Type III R5 Type V Options Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Globe AY PY Acrylic Polycarbonate Paint (blank) Black VG Verde Green BZ Bronze Lamp LC LD Photocontrol (blank) None BC Button Photocontrol Misc SS Stainless Steel Fasteners (external) Lamp Included, Clear Lamp Included, Deluxe/Coated See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 85 American Revolution Series 247 50-150W HPS, 100-175W MV, 175W MH P R O D U C T O V E R V I E W Features: Die-cast aluminum housing and hood for long-life performance. Optical assembly designed for maximum performance. Hinged hood and captive screw provision afford quick, easy access to electrical and optical area for relamping or servicing. Slipfitter with three set screws allows secure installation to pole sizes 2-3/8" or 3" OD. E39 mogul base socket standard. All electrical components warranted by American Electric Lighting's 6-year guarantee. Complies with ANSI: C136.2, C136.10, C136.15, C136.3.1 Suitable for -30°C MH & MV / -40°C HPS. Applications: Streetscapes Walkways Pathways Parks DIMENSIONS 17" (432) 25.5" (648) Effective Projected Area (EPA) The EPA for the American Revolution Series 247 is 1.6 sq. ft. Approx. Wt. = 36 lbs. 86 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com American Revolution Series 247 50-150W HPS, 100-175W MV, 175W MH O R D E R I N G I N F O R M AT I O N Example: 2 4 7 1 5 S R N 1 2 0 R 5 A Y E C Wattage / Source Series 247 American Revolution Post Top 05 07 10 15 17 00 50W 70W 100W 150W 175W Incandescent S M V X Voltage Ballast HPS MH MV Incandescent (order with XX ballast option) RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor CA CWA Autotransformer CT CWI Autotransformer MR Mag Reg (3 coil)1 XX No Ballast Refer to ballast matrix on page 136 for compatibility. 120 208 220 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 DT2 DT3 Options DT4 Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Paint4 (blank) GY WH BZ Black (standard) Gray White Bronze Lamp LC LD LG Starter8 Terminal Block (blank) (blank) Terminal Block (standard) EC T2 Wired to L1 & L2 Position OP T3 3 Wire Operation (L1, N, L2 Position) SN Listing UL CS Fusing5 SF DF UL Listed CSA Certified Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle6 PB Phosphor Bronze Contacts Misc. PC SS 5H NL HS WS PU TL 120V 208V 220V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual Tap 120/240 wired 120V Dual Tap 120/240 wired 240V Dual Tap 240/480 wired 240V Dual Tap 240/480 wired 480V Distribution R2 R3 R5 RV Type II Type III Type V2 Type V3 Optics AY Acrylic PY Polycarbonate Refer to Optical Matrix below for compatibility Notes: Lamp Included, Clear Lamp Included, Deluxe/Coated Self-igniting Lamp7 1 2 3 4 Open Board (standard) Encapsulated Plug-in Open Plug-in No ignitor (use self-igniting lamp) Photocontrol Included per Voltage Specified Stainless Steel Hardware 50 Hertz Ballast Cycle9 NEMA Label (2x2) Houseside Shield Wildlife Shield (cupola) Without Cupola Tool-less Entry 5 6 7 8 9 MR not available with UL and CSA listing Four white panels Four clear panels Other colors available, please contact your local American Electric Lighting representative Voids UL/CSA Certified Options not available with multi-tap voltage options PB, PC, SH not available with PR option Requires SN option HPS only Limited availability, please contact your local American Electric Lighting representative Optic Distribution 05S 07S 10S 15S 17M 17V R2 AY R3 AY R5 AY RV AY R2 PY ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ See pages 259-264 for a complete listing of Frequently Ordered Products R3 PY R5 PY RV PY ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ Product Guide 87 American Revolution Cutoff Series 247 50-150W HPS P R O D U C T O V E R V I E W Features: NEW Die-cast aluminum housing and hood for long-life performance. Optical assembly designed for maximum performance. Hinged hood and captive screw provision afford quick, easy access to electrical and optical area for relamping or servicing. Slipfitter with three set screws allows secure installation to pole sizes 2-3/8" or 3" OD. Meets IESNA Full Cutoff classification. All electrical components warranted by American Electric Lighting's 6-year guarantee. Complies with ANSI: C136.2, C136.10, C136.15, C136.16. Applications: Streetscapes Walkways Pathways Parks DIMENSIONS ZONAL LUMEN SUMMARY Zone Downward Street Side Downward House Side Downward Total Upward Street Side Upward House Side Upward Total Total 17" (432) 25.5" (648) Effective Projected Area (EPA) The EPA for the American Revolution Series 247 is 1.6 sq. ft. Approx. Wt. = 36 lbs. 88 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Lumens 3206.3 1983.3 5189.6 0.0 0.0 0.0 5189.6 %Lamp 33.8 20.9 54.6 0.0 0.0 0.0 54.6 American Revolution Cutoff Series 247 50-150W HPS O R D E R I N G I N F O R M AT I O N Example: 2 4 7 1 5 S R N 1 2 0 R 2 F C P C Wattage / Source Series 247 American Revolution Post Top 05 07 10 15 50W 70W 100W 150W S HPS Voltage Ballast RN Reactor Normal XX No Ballast 120 120V Distribution R2 Type II Optics FC Full Cut-off Options Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Paint1 (blank) GY WH BZ Black (standard) Gray White Bronze Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Position Fusing SF Single Fuse Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle2 PB Phosphor Bronze Contacts Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Starter (blank) Open Board (standard) Misc. PC SS NL WS SH PU TL Notes: 1 2 Other colors available, please contact your local American Electric Lighting representative PB, PC, SH not available with PR option Photocontrol Included per Voltage Specified Stainless Steel fasteners (external) NEMA Label (2x2) Wildlife Shield (cupola) Shorting Cap Without Cupola Tool-less Entry See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 89 Contempo Series 245 35-400W HPS, 100-400W MV, 70-400 MH P R O D U C T O V E R V I E W Features: Die-cast aluminum housing and spun aluminum hood for long-life performance. Optical assembly designed for maximum performance. Multi-gasketing to provide weatherproof protection of optical assembly for full illumination performance. Hinged hood and captive screw latching provision afford quick, easy access to electrical and optical area for relamping or servicing. Available with two different style hoods and an added scroll option for a more decorative look. Cone mounting fitter with three set screws allows secure installation to pole sizes 2-3/8" or 3" OD. Refractor available in tempered glass, acrylic and polycarbonate. Available in a variety of IES light distributions patterns. E39 mogul base socket standard. Applications: All electrical components warranted by American Electric Lighting's 6-year guarantee. Streetscapes Walkways Pathways Parks Complies with ANSI: C136.2, C136.10, C136.15, C136.16. Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS 22" (559) 22" (559) 25-1/2" (648) 20" (508) 3-1/4" (83) 3-1/4" (83) STYLE A STYLE D Effective Projected Area (EPA) The EPA for the Contempo Series 245 is 1.3 sq. ft. Approx. Wt. = 32 lbs. DIMENSIONS 22" (559) 22" (559) 25-1/2" (648) 20" (508) 3-1/4" (83) 3-1/4" (83) STYLE A STYLE D Effective Projected Area (EPA) The EPA for the Decorative Scroll Option is 1.8 sq. ft. Approx. Wt. = 32 lbs. 90 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Contempo Series 245 35-400W HPS, 100-400W MV, 70-400W MH O R D E R I N G I N F O R M AT I O N O R D E R I N G I N F O R M AT I O N Example: 2 4 5 1 0 S R N 1 2 0 R 3 G L S D P C Wattage / Source Series 245 Contempo Post Top 03 05 07 10 13 14 15 17 20 25 31 40 35W 50W 70W 100W 130W 140W 150W 175W 200W 250W 310W 400W RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor CA CWA Autotransformer CT CWI Autotransformer MR Mag Reg (3 coil) XX No Ballast S HPS M MH V MV Refer to ballast matrix on page 136 for compatibility. Options Distribution Voltage Ballast 120 208 220 230 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 DT2 DT3 DT4 120V 208V 220V 230V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual Tap 120/240 wired 120V Dual Tap 120/240 wired 240V Dual Tap 240/480 wired 240V Dual Tap 240/480 wired 480V R2 R3 R4 R5 Type II Type III Type IV Type V Optics GL Glass AY Acrylic PY Polycarbonate Refer to Optical Matrix below for compatibility Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Paint1 (blank) BK WH BZ Gray (standard) Black White Bronze Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Listing UL CS UL Listed CSA Certified Fusing2 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle3 PB Phosphor Bronze Contacts Lamp LC LD LG Starter5 (blank) EC OP SN Lamp Included, Clear Lamp Included, Deluxe/Coated Self-igniting Lamp4 Open Board (standard) Encapsulated Plug-in Open Plug-in No ignitor (use self-igniting lamp) Hood Style (see line art) (blank) Style A SD Style D Notes: 1 2 Misc. PC Photocontrol Included per Voltage Specified Stainless Steel Hardware 50 Hertz Ballast Cycle6 NEMA Label Decorative Scroll Design (Standard Black) Shorting Cap SS 5H NL DD SH 3 4 5 6 Other colors available, please contact your local American Electric Lighting representative Voids UL/CSA not available in MT, TT, DT, voltages PB, PC, SH not available with NR option Requires SN option Available in HPS only Limited availability, please contact your local American Electric Lighting representative Optic Distribution 03S 05S 07S 10S 15S 20S 25S 31S 40S 17M 25M 40M 17V 25V 40V R2 AY R3 AY R4 AY R5 AY R2 PY R3 PY ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ - See pages 259-264 for a complete listing of Frequently Ordered Products R4 PY ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ - R5 PY R2 GL ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ R3 GL R5 GL ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ Product Guide 91 Residential Post Top Series RES 35-70W HPS P R O D U C T O V E R V I E W Features: NEW Compact post top light, ideal for retrofitting inefficient incandescent units. Attractive, complements virtually any style architecture. Easy access to lamp compartment for quick relamping. All electrical components warranted by American Electric Lighting's 6-year guarantee. Complies with ANSI: C136.2, C136.10, C136.15, C136.16. Applications: Residential areas Architectural landscape lighting Recreational areas Commercial environments Parks, Walkways DIMENSIONS 17.75" (451) 9.50" (241) Effective Projected Area (EPA) The EPA for the RES is 2.93 sq. ft. Approx. Wt. = 8 lbs. 92 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Residential Post Top Series RES 35-70W HPS O R D E R I N G I N F O R M AT I O N Example: R E S O 5 S R N 1 2 0 R 5 P Y Wattage / Source Series RES Residential Post Top 00 03 05 07 S Use for incandescent 35W 50W 70W Voltage Ballast HPS RN Reactor NPF 120 120V Optics Distribution R5 Type PY Polycarbonate Options Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Color (blank) Black (standard) Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Photocontrol (blank) Button Photocontrol (standard) NC No photocontrol See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 93 TwistPackTM Series TWT 50-150W HPS P R O D U C T O V E R V I E W Features: NEW Unique twistlock feature with locking screw that allows easy removal of optical assembly from slipfitter casting. Slipfitter casting houses ballast. It will fit over a post having top diameter of 3-1/2” (4”OD) or 3” (3-1/2OD). Slipfitter casting is secured to post by three Allen-head locking screws. Some components of the ballast (e.g. capacitors and/or ignitors) depending on wattage or type, may extend below the slipfitter casting and may have to fit in the top of the pole. Aluminum hoods are available in either 24” or 28” diameter. Refractors offered in IES Type II, and V distributions. Available in polycarbonate or acrylic refractors. Mogul base socket. Natural aluminum finish. NEMA type photocell receptacle is standard. Applications: CSA certified option available. Shopping Malls Parks Campuses Residential Streets Condominiums Walkways All electrical components warranted by American Electric Lighting's 6-year guarantee. Complies with ANSI: C136.2, C136.10, C136.15, C136.16. DIMENSIONS 28.63" (727) 24.38" (619) 24.75" (629) 26.63" (676) Effective Projected Area (EPA) The EPA for the TwistPack is 1.88 sq. ft. Approx. Wt. = 41 lbs. 94 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com TwistPackTM Series TWT 50-150W HPS O R D E R I N G I N F O R M AT I O N Example: T W T 1 5 S R N 1 2 0 R 5 A Y H 8 Wattage / Source Series TWT TwistPack 05 07 10 15 17 25 00 50W M 70W S 100W V 150W X 175W 250W Use for incandescent Metal Halide HPS Mercury Vapor Incandescent CA CWA Autotransformer CT CWI Autotransformer RH Reactor High Power Factor RN Reactor Normal Power Factor XH High Reactance/Lag High Power Factor XN High Reactance/Lag Normal Power Factor XX No Ballast Refer to ballast matrix on page 137 for compatibility. Distribution Voltage Ballast 120 208 240 277 347 600 DT1 DT2 MT1 MT2 MT7 MT8 TT1 TT3 TT7 R2 120V R5 208V 240V 277V 347V 600V Dual Tap 120/240 wired 120 Dual Tap 120/240 wired 240 Multi-tap wired 120 Multi-tap wired 240 Multi-tap wired 277 Multi-tap wired 208 Tri-tap wired 120 Tri-tap wired 347 Tri-tap wired 277 Roadway Type II Type V Optics AY Acrylic PY Polycarbonate1 Hood H4 H8 24” hood 28” hood Options Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Terminal Block Photocontrol Receptacle T2 Wired to L1 & L2 Positions (blank) NEMA Photocontrol T3 3 Wire Operation (L1, N, L2 Position) Receptacle (standard) NR No Photocontrol Receptacle3 Listing CS CSA Certified Lamp LC Lamp Included, Clear Supply Wire LD Lamp Included, Deluxe/Coated PW Pre-wire (slip fitter only) PW15 Pre-wire for attached Starter4 PW20 #14 CU SOLID B/W EC Encapsulated Plug-in PW25 #14 CU SOLID B/W OP Open Plug-in PA15 #10 CU SOLID B/W PA20 #10 CU SOLID B/W Misc. PA25 #10 CU SOLID B/W PC Photocontrol Included per PB15 #10 CU SOLID B/B voltage specified PB20 #10 CU SOLID B/B NL NEMA Label PB25 #10 CU SOLID B/B SH Shorting Cap PC15 #10 CU SOLID B/B/W SS Stainless Steel Hardware PC20 #10 CU SOLID B/B/W PC25 #10 CU SOLID B/B/W PD15 #10 CU STRAND B/W PD20 #10 CU STRAND B/W PD25 #10 CU STRAND B/W PE15 #10 CU STRAND B/W PE20 #10 CU STRAND B/B PE25 #10 CU STRAND B/B PF15 #10 CU STRAND B/B/W PF620 #10 CU STRAND B/B/W PF25 #10 CU STRAND B/B/W PG15 #12 CU SOLID B/W See pages 259-264 for a complete listing of Frequently Ordered Products Notes: 1 2 3 4 PY available in HPS only H4 available in 175W and below PC and SH not available with NR option HPS only Product Guide 95 Bainbridge Series 870 50-150W HPS,100-175W MV, 175W MH P R O D U C T O V E R V I E W Features: NEW Architecturally complementary design. Powdercoated, paint finish. Terminal block for ease of wiring. A variety of wattages and ballast types. Available in HPS,MH, and MV. Easy access to electrical components. Available in a variety of IES distributions. E39 mogul base socket standard. All electrical components warranted by AEL’s 6-year guarantee. Complies with ANSI: C136.2, C136.10, C136.15, C136.31. Suitable for -30°C MH & MV / -40°C HPS. Applications: Office Buildings Shopping centers Malls Apartment/condominium complexes Commercial developments DIMENSIONS 16.5" (419) 27" (686) 37" (940) Effective Projected Area (EPA) The EPA for the Bainbridge Series 870 is 3.7 sq. ft. Approx. Wt. = 28 lbs. 96 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Bainbridge Series 870 50-150W HPS,100-175W MV, 175W MH O R D E R I N G I N F O R M AT I O N Example: 8 7 0 1 0 S C A M T 1 R 3 A Y L C Series 870 Bainbridge Wattage / Source 05 07 10 15 17 50W 70W 100W 150W 175W S HPS M MH V MV Voltage Ballast CA CWA Autotransformer RH Reactor High Power Factor RN Reactor Normal Power Factor XH High Reactance / Lag High Power Factor XN High Reactance / Lag Normal Power Factor CT CWI Autotransformer Refer to ballast matrix on page 137 for compatibility. 120 208 240 277 347 480 DT1 120V 208V 240V 277V 347V 480V Dual Tap 120/240 wired 120 Dual Tap 120/240 wired 240 Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120 Tri-tap wired 277 Tri-tap wired 347 DT2 MT1 MT8 MT2 MT7 TT1 TT7 TT3 Distribution R3 Type III R5 Type V R0 No internal refractor Optics AY Acrylic PY Polycarbonate Options Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Paint (blank) BZ VG Black (standard) Bronze Antique Verde Green Terminal Block T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Lamp LC LD Photocontrol (blank) None BC Button-photocontrol Misc. FR SS NL 9R Notes: 1 Achieved with internal glass refractor Decorative Frond Stainless Steel Hardware NEMA Label 9”Globe neck Lamp Included, Clear Lamp Included, Deluxe/Coated See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 97 Georgian Series GRP 50-150W HPS, 50 - 175W MV/MH P R O D U C T O V E R V I E W Features: NEW Two (2) piece cast aluminum housing. Castings are hinged and open with a simple 1/4 turn thumb screw for easy maintenance. Choice of 2 mounting arrangements: side entry or post top. Wide choice of optical systems, see optical system options for proper IES distribution. All options windows are sealed with neoprene gaskets to prevent ingress of dirt or moisture in luminaire. Bottom lens is sealed with a felt gasket for proper breathing of luminaire (top entry and side entry units only). All ballasts are mounted on a ballast plate with quick disconnect, for easy replacement. All exposed screws are stainless steel. Cast aluminum slipfitter accepts 3” to 3-1/2” OD X 4” long tenon or pole. Mounting hardware included. A photocell cupola is supplied when ordering the photocell receptacle (only available with post top (GRT) and side entry (GRS) models). Applications: Mogul base socket. Residential areas Architectural landscape lighting Parks, walkways Recreational areas Commercial environments Certified by CSA to CSA and UL standards. All electrical components warranted by American Electric Lighting's 6-year guarantee. Complies with ANSI: C136.2, C136.10, C136.15, C136.16 DIMENSIONS 19.6" (498) 34.9" (886) 4.1" (104) Effective Projected Area (EPA) The EPA for the Georgian is 2.93 sq. ft. Approx. Wt. = 46 lbs. 98 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Georgian Series GRP 50-150W HPS, 50 - 175W MV/MH O R D E R I N G I N F O R M AT I O N Example: G R P 1 0 S R H 1 2 0 R 3 P Y L C GRP Georgian Ballast Wattage / Source Series 05 10 15 17 50W 100W 150W 175W CA CWA Autotransformer CT CWI Autotransformer RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor MR Mag-Reg (3 coil) M MH S HPS V MV Refer to ballast matrix on page 138 for compatibility. Distribution Voltage 120 208 240 277 347 DT1 DT2 MT1 MT2 MT7 MT8 TT1 TT3 TT7 120V 208V 240V 277V 347V Dual Tap 120/240 wired 120 Dual Tap 120/240 wired 240 Multi-tap wired 120 Multi-tap wired 240 Multi-tap wired 277 Multi-tap wired 208 Tri-tap wired 120 Tri-tap wired 347 Tri-tap wired 277 R2 Roadway Type II R3 Type III Optics GL Glass PY Polycarbonate Options Maximum number of options is six. For more options, please contact your local American Electric Lighting representative. Paint (blank) BZ Black (standard) Bronze Starter1 EC Encapsulated Plug-in OP Open Plug-in Notes: 1 HPS only Photocontrol Terminal Block (blank) None T2 Wired to L1 & L2 Positions PC Photocontrol included T3 3 Wire Operation (L1, N, L2 Position) Listing CS CSA Certified Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Misc. SS NL Stainless Steel Hardware NEMA Label See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 99 Heritage Poles Chadsworth Series Cast Aluminum Posts Extruded Shaft P R O D U C T O V E R V I E W Features: INSTALLATION The post shall be provided with four, hot-dip galvanized L-type anchor bolts to be installed on a 10" - 12" diameter bolt circle. A door shall be provided in the base for anchorage and wiring access. A grounding screw shall be provided inside the base opposite the door. MATERIALS The base shall be heavy wall, copper-free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B179-95a or ASTM B26-95. The straight shafts shall be extruded from aluminum, ASTM 6061 alloy, heat treated to a T6 temper. The tapered shaft shall be extruded from aluminum, ASTM 6063 alloy, spun to a tapered shape, then heat treated to a T6 temper. All hardware shall be tamper-resistant stainless steel. Anchor bolts to be completely hot-dip galvanized. Smooth Fluted 12'-0" CONSTRUCTION The shaft shall be double welded to the base casting and shipped as one piece for maximum structural integrity. The shaft shall be circumferentially welded inside the base casting at the top of the access door, and externally where the shaft exits the base. All exposed welds below 8’ shall be ground smooth. All welding shall be per ANSI/AWS D1.2-90. All welders shall be certified per Section 5 of ANSI/AWS D1.2-90. DIMENSIONS The post shall be X’- XX" in height with a 16" diameter base. The shaft diameter shall be XX". (See page 101.) At the top of the post, an integral 3" O.D. x 3" tenon with a transitional donut shall be provided for luminaire mounting. Tapered Applications: Streetscapes Walkways Pathways Parks 100 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Heritage Poles Chadsworth Series Cast Aluminum Posts Extruded Shaft O R D E R I N G I N F O R M AT I O N Example: P X C H 1 6 1 2 S 5 A N B K A E L AEL Series Height PX CH16 Chadsworth 8’ 10’ 12’ 14’ 16’1 Shaft Type S4 S5 F4 F5 T4 T5 Smooth 4"Ø Smooth 5"Ø Fluted 4"Ø Fluted 5"Ø Tapered 4"-3"Ø Tapered 5"-3"Ø Options Manufacturing Code _________ Receptacles _________ Banner Arms _________ Flagpole Holders _________ Signage AEL Finish2 ANBK ANDB ANDG CM CS Black Bronze Dark Green Custom Match Custom Select RAL colors (See Accessories section or contact your local AEL representative.) Notes: 1 2 16' height not available for S4, F4, or T4 (any 4"Ø) Shaft Type For finish specifications and color options, please contact your local American Electric Lighting representative DIMENSIONS 8.49" 7.07" 8.5" Dia. Opening Door Opening 10" Dia. 10" - 12" Bolt 12" Circle 2" Hot Dip Galvanized L-type Anchor Bolts (4 per Post) See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 101 Heritage Poles New Albany Series Cast Aluminum Posts Extruded Shaft P R O D U C T O V E R V I E W Features: INSTALLATION The post shall be provided with four, hot-dip galvanized L-type anchor bolts to be installed on a 12" diameter bolt circle. A door shall be provided in the base for anchorage and wiring access. A grounding screw shall be provided inside the base opposite the door. MATERIALS The base shall be heavy wall, copper-free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B-179-95a or ASTM B26-95. The straight shafts shall be extruded from aluminum, ASTM 6061 alloy, heat treated to a T6 temper. The tapered shaft shall be extruded from aluminum, ASTM 6063 alloy, spun to a tapered shape, then heat treated to a T6 temper. All hardware shall be tamperresistant stainless steel. Anchor bolts to be completely hot-dip galvanized. Smooth Fluted 12'-0" CONSTRUCTION The shaft shall be double welded to the base casting and shipped as one piece for maximum structural integrity. The shaft shall be circumferentially welded inside the base casting at the top of the access door, and externally where the shaft exits the base. All exposed welds below 8’ shall be ground smooth. All welding shall be per ANSI/AWS D1.2-90. All welders shall be certified per Section 5 of ANSI/AWS D1.2-90. DIMENSIONS The post shall be X’- XX" in height with a 17" diameter base. The shaft diameter shall be XX". (See page 103.) At the top of the post, an integral 3" O.D. x 3" tenon with a transitional donut shall be provided for luminaire mounting. Tapered Applications: Streetscapes Walkways Pathways Parks 102 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Heritage Poles New Albany Series Cast Aluminum Posts Extruded Shaft O R D E R I N G I N F O R M AT I O N Example: P X N Y 1 7 1 2 S 5 A N B K A E L AEL Series Height PX NY17 New Albany 8’ 10’ 12’ 14’ 16’1 Finish2 Shaft Type S4 S5 F4 F5 T4 T5 Smooth 4"Ø Smooth 5"Ø Fluted 4"Ø Fluted 5"Ø Tapered 4"-3"Ø Tapered 5"-3"Ø ANBK ANDB ANDG CM CS Black Bronze Dark Green Custom Match Custom Select RAL colors Manufacturing Code Options _________ Receptacles _________ Banner Arms _________ Flagpole Holders _________ Signage (See Accessories section or contact your local AEL representative.) Notes: 1 2 16' height not available for S4, F4, or T4 (any 4"Ø) Shaft Type For finish specifications and color options, please contact your local American Electric Lighting representative DIMENSIONS 8.5" Door Opening 10" Dia. Opening 12" Dia. Bolt Circle 2" Hot Dip Galvanized L-type Anchor Bolts (4 per Post) See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 103 Heritage Poles Statesboro Series Cast Aluminum Posts Extruded Shaft P R O D U C T O V E R V I E W 12'-0" Features: INSTALLATION The post shall be provided with four, hot-dip galvanized L-type anchor bolts to be installed on a 9.5" diameter bolt circle. A door shall be provided in the base for anchorage and wiring access. A grounding screw shall be provided inside the base opposite the door. MATERIALS The base shall be heavy wall, copper free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B179-95a or ASTM B26-95. The straight shafts shall be extruded from aluminum, ASTM 6061 alloy, heat treated to a T6 temper. The tapered shaft shall be extruded from aluminum, ASTM 6063 alloy, spun to a tapered shape, then heat treated to a T6 temper. All hardware shall be tamper-resistant stainless steel. Anchor bolts to be completely hot-dip galvanized. Smooth Fluted Applications: Streetscapes Walkways Tapered CONSTRUCTION The shaft shall be double welded to the base casting and shipped as one piece for maximum structural integrity. The shaft shall be circumferentially welded inside the base casting at the top of the access door, and externally where the shaft exits the base. All exposed welds below 8’ shall be ground smooth. All welding shall be per ANSI/AWS D1.2-90. All welders shall be certified per Section 5 of ANSI/AWS D1.2-90. DIMENSIONS The post shall be X’- XX" in height with a 9" diameter base. The shaft diameter shall be XX". (See page105.) At the top of the post, an integral 3" O.D. x 3" tenon with a transitional donut shall be provided for luminaire mounting. Pathways Parks DIMENSIONS 104 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Heritage Poles Statesboro Series Cast Aluminum Posts Extruded Shaft O R D E R I N G I N F O R M AT I O N Example: P X S 9 1 2 S 4 A N B K A E L AEL Series Height PX S9 Statesboro 8’ 10’ 12’ 14’ S4 Smooth 4"Ø F4 Fluted 4"Ø T4 Tapered 4"-3"Ø ANBK ANDB ANDG CM CS Manufacturing Code Options Finish2 Shaft Type Black Bronze Dark Green Custom Match Custom Select RAL colors _________ Receptacles _________ Banner Arms _________ Flagpole Holders _________ Signage (See Accessories section or contact your local AEL representative.) Set Screws Door Opening 8" Sq. Base Plate 6.72" 9.5" Dia. Bolt Circle 9" Sq. Base Cover 7" 2" Hot Dip Galvanized L-type Anchor Bolts (4 per Post) See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 105 Heritage Poles Waycross Series Cast Aluminum Posts Extruded Shaft P R O D U C T O V E R V I E W Features: INSTALLATION The post shall be provided with four, hot-dip galvanized L-type anchor bolts to be installed on 12" diameter bolt circle. A door shall be provided in the base for anchorage and wiring access. A grounding screw shall be provided inside the base opposite the door. MATERIALS The base shall be heavy wall, copper-free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B-179-95a or ASTM B26-95. The straight shafts shall be extruded from aluminum, ASTM 6061 alloy, heat treated to a T6 temper. The tapered shaft shall be extruded from aluminum, ASTM 6063 alloy, spun to a tapered shape, then heat treated to a T6 temper. All hardware shall be tamper-resistant stainless steel. Anchor bolts to be completely hot-dip galvanized. Smooth Fluted 12'-0" CONSTRUCTION The shaft shall be double welded to the base casting and shipped as one piece for maximum structural integrity. The shaft shall be circumferentially welded inside the base casting at the top of the access door, and externally where the shaft exits the base. All exposed welds below 8’ shall be ground smooth. All welding shall be per ANSI/AWS D1.2-90. All welders shall be certified per Section 5 of ANSI/AWS D1.2-90. DIMENSIONS The post shall be X’- XX" in height with a 17" diameter base. The shaft diameter shall be XX". (See page 107.) At the top of the post, an integral 3" O.D. x 3" tenon with a transitional donut shall be provided for luminaire mounting. Tapered Applications: Streetscapes Walkways Pathways Parks 106 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Heritage Poles Waycross Series Cast Aluminum Posts Extruded Shaft O R D E R I N G I N F O R M AT I O N Example: P X W 1 7 1 2 S 5 A N B K A E L AEL Series PX W17 Waycross 8’ 10’ 12’ 14’ 16’1 S4 S5 F4 F5 T4 T5 Smooth 4"Ø Smooth 5"Ø Fluted 4"Ø Fluted 5"Ø Tapered 4"-3"Ø Tapered 5"-3"Ø Options Manufacturing Code _________ Receptacles _________ Banner Arms _________ Flagpole Holders _________ Signage AEL Finish2 Shaft Type Height ANBK ANDB ANDG CM CS Black Bronze Dark Green Custom Match Custom Select RAL colors (See Accessories section or contact your local AEL representative.) Notes: 1 2 16' height not available for S4, F4, or T4 (any 4"Ø) Shaft Type For finish specifications and color options, please contact your local American Electric Lighting representative DIMENSIONS 8.5" 10" Dia. Opening Door Opening 12" Dia. Bolt Circle 2" Hot Dip Galvanized L-type Anchor Bolts (4 per Post) See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 107 Heritage Series Weatherproof Receptacles External, Post Shaft Location P R O D U C T O V E R V I E W Features: INSTALLATION External receptacles typically are installed above pedestrian level for special event uses and decorative seasonal lighting. CONSTRUCTION External receptacles typically are installed above pedestrian level for special event uses and decorative seasonal lighting. Ground Fault Circuit Interrupter Receptacles. Test/Reset buttons on face of receptacles. All Cast Aluminum Covers. Not Plastic. (Paintable to match post color). Weatherproof “While-in-Use” covers in two sizes. Receptacle with Wet Location While Closed Cover Post Shaft Catalog part # FG-S Duplex Receptacle with Ground Fault Interrupter 3/4" 2 7/8" 4 1/2" SPECIFICATIONS A 20 amp, 125 volt, ground fault circuit interrupter duplex receptacle shall be mounted in the post. The receptacle shall be UL Listed according to E-48380 and UL 943 Class A and UL 498. The receptacle shall have a cast aluminum, UL Listed cover that is suitable for wet locations while not in use. The receptacle and cover shall mount to an outlet opening, in the post shaft, with a gasket and stainless steel screws. Wet Location when closed Cover Receptacle with Small, In-Use Wet Location Cover Duplex Receptacle with Ground Fault Interrupter Catalog part # FGIUS-S 3 3/8" 2 3/8" Small, Wet Location while in use Cover (for use with two 3/8" max. dia. cords) LIFT OPEN 5 3/4" SPECIFICATIONS A 20 amp, 125 volt, ground fault circuit interrupter duplex receptacle shall be mounted in the post. The receptacle shall be UL Listed according to E-48380 and UL 943 Class A and UL 498. The receptacle shall have a cast aluminum, lockable, UL Listed cover that is suitable for wet locations while in use and complies with NEC Article 41057(b). The cover shall accept most common cord sets up to 3/8” diameter (14/3). The receptacle and cover shall mount to an outlet opening, in the post shaft, with a gasket and stainless steel screws. Receptacle with Large, In-Use Wet Location Cover Catalog part # FGIUL-S Duplex Receptacle with Ground Fault Interrupter 3 3/8" 3 3/8" Large, Wet Location while in use Cover (for use with two 1/2" max. dia. cords) 108 Product Guide LIFT OPEN 5 3/4" SPECIFICATIONS A 20 amp, 125 volt, ground fault circuit interrupter duplex receptacle shall be mounted in the post. The receptacle shall be UL Listed according to E-48380 and UL 943 Class A and UL 498. The receptacle shall have a cast aluminum, lockable, UL Listed cover that is suitable for wet locations while in use and complies with NEC Article 41057(b). The cover shall accept most common cord sets up to 1/2” diameter (12/3). The receptacle and cover shall mount to an outlet opening, in the post shaft, with a gasket and stainless steel screws. For photometric information, visit our website, www.americanelectriclighting.com Heritage Series Weatherproof Receptacles External, Post Shaft Location P R O D U C T O V E R V I E W Features: INSTALLATION Internal receptacles typically are installed for use by authorized personnel for special events and owner maintenance purposes. CONSTRUCTION Ground fault circuit interrupter receptacles. Test and reset buttons on face of receptacles. All cast aluminum covers, not plastic. Duplex Receptacle with Ground Fault Interrupter Weatherproof Box Weatherproof Cover Receptacle with Weatherproof Box and Cover Catalog part # RB/GFI/WPC SPECIFICATIONS A 20amp, 125 volt, ground fault circuit interrupter duplex receptacle shall be mounted inside the post base, facing toward the access door. The receptacle shall be UL Listed according to E-48380 and UL 943 Class A and UL 498. The receptacle shall be mounted in a cast aluminum box and cover that is suitable for wet locations while not in use. The receptacle and cover shall mount to an outlet box with a gasket and stainless steel screws. See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 109 Heritage Series Banner Arms Cast Aluminum P R O D U C T O V E R V I E W Features: Removable Standard Half Sphere Cap (H) Standard 1" Pipe Arm (1.32" O.D.) 1-1/2" Pipe Arm (1.9" O.D.) 24" or required length BA24H/1/BO (banner arm, 24”lg., 1.0, with bolt-on mounting) BA24H/1.5/BO (banner arm, 24”lg., 1.5, with bolt-on mounting) Other Size Banner Arms Available: BAXXH/.75 BAXXH/1.25 [banner arm, XX” lg., 3/4” pipe (1.05”O.D) ] [banner arm, XX” lg., 1-1/4” pipe(1.66”O.D.)] Other Mounting Options BA24H/1/CO (banner arm, with clamp-on mounting) EB/BO (eyebolt mounted to post for securing banner bottom) EB/CO (eyebolt with clamp on mounted for securing banner bottom) BAXXB (ball end cap) BAXXA (acorn end cap) BBA24H/1/BO (break-away banner arm) BAXXR (raleigh end cap) 110 Product Guide MATERIALS The end caps shall be, copper-free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B179-95a or ASTM B26-95. The banner arm, mounting plate and post clamp shall be aluminum, ASTM 6061 alloy, heat treated to a T6 temper. All hardware shall be stainless steel. CONSTRUCTION The banner arm shall be welded to a mounting plate or a post clamp. All welding shall be per ANSI/AWS D1.2-90. All welders shall be certified per ANSI/AWS D1.2-90 Section 5. DIMENSIONS The banner arms shall be available in 1.05”, 1.32”, 1.66” or 1.9” O.D. and at the specified length. Applications: Other Options BA24H/1/BO/2EB (two eyebolts on arm) INSTALLATION The bolt-on banner arm shall bolt to a mounting channel provided on the side of the post with four stainless steel screws. Eyebolts shall screw in to the post or clamp-on. All clamp-on mountings shall clamp around the post, secured with four 3/8” hex head bolts. (Post dia. at mounting point must be specified.) A minimum mounting height of 10 feet is recommended for the bottom banner arm. (Arms are not designed for pedestrian interference.) For information on specifying orientation and mounting heights, see Orientation Guide, page 130. BA24H/1/BO/S/2EB (decorative scroll and two eyebolts on arm) For photometric information, please visit our website, www.americanelectriclighting.com Streetscapes Walkways Pathways Parks Heritage Series Banner Arms Cast Aluminum O R D E R I N G I N F O R M AT I O N Example: B A C 1 9 B A C D 4 1 8 H 4 B A E B E B C 1 9 E B C D 4 A N B K A E L AEL Length/End Cap/ Arm Dia. 12 H Half Sphere 18 B Ball Cap 19 A Acorn Cap 20 R Raleigh Cap 24 Arm Dia. 25 26 3 3/4”O 28 4 1”O 30 5 1-1/4”O 36 6 1-1/2”O Banner Arms1,2 BAB 2BAB 3BAB 4BAB 6BAB 8BAB One Set BAC19 BAC28 BAC29 BAC39 BAC49 One Two Three Four Six Eight Two Sets One 2BAC19 Two @ 180 2BAC28 Two @ 90 2BAC29 Three @ 90 2BAC39 Four @ 90 2BAC49 Options BBA Breakaway Arm BAEB Arm w/eyebolts BAEBS Arm w/eyebolts and scroll Eyebolts (type, qty) EBB 2EBB 3EBB 4EBB One Set EBC19 EBC28 EBC29 EBC32 EBC39 EBC49 BA Clamp Dia.2,3 BACD3 BACD3-1/2 BACD4 BACD4-1/2 BACD5 BACD5-1/2 BACD6 BACD6-1/2 BACD7 BACD7-1/2 BACDTBS 3”O 3-1/2”O 4”O 4-1/2”O 5”O 5-1/2”O 6”O 6-1/2”O 7”O 7-1/2”O 0 to be specified One Two Three Four Two Sets One 2EBC19 Two @ 180 2EBC28 Two @ 90 2EBC29 Three @120 2EBC32 Three @ 90 2EBC39 Four @ 90 2EBC49 Manufacturing Code 3”O 3-1/2”O 4”O 4-1/2”O 5”O 5-1/2”O 6”O 6-1/2”O 7”O 7-1/2”O 0 to be specified AEL Finish4 ANBK ANDB ANDG ANVG ANPP CM CS Black Dark Bronze Dark Green Verde Green Prime Painted Custom Match Custom Select RAL colors 1 For information on specifying orientation and mounting heights, see Orientation Guide, page 130 2 A minimum mounting height of 10' is recommended for the bottom banner arm 3 For clamp dia., take post dia. and round up to the nearest 1/2" 4 For finish and color options, please contact your local AEL representative XX" Clamp with (4) 3/8" Hex Hd. Bolts to Clamp On Post (4) Stainless Steel Screws to Post BAB XXH4 xx" Clamp-On Mounting BAC19 BACDxx XXH4 2BBA26H/1/BO* (2 Break-away Banner Arms, 26”, Half sphere and cap/1”0/Bolt-on) SUGGESTED BANNER ARM USAGE EBCD3 EBCD3-1/2 EBCD4 EBCD4-1/2 EBCD5 EBCD5-1/2 EBCD6 EBCD6-1/2 EBCD7 EBCD7-1/2 EBCDTBS Notes: XX" Bolt-On Mounting EB Clamp Dia. 2,3 30" 28" wide banner Note: * For arms for two banners with bolt on option add 2 before the arm and eyebolt part no. BA18R/1.25/CO2(180)5 (Banner Arms, 18”, Raleigh end cap/1.25”0/ ClampOn, 2 arms at 180 degrees, 5” 0 post shaft) 26" 18" 24" wide banner 16" wide banner Note: * For arms for two banners with bolt on option add 4 before the arm part no. EBB* (EyeBolt, Bolt-on) Notes: * For information on specifying orientation and mounting heights, see Orientation Guide on page 130. A minimum mounting height of 10’ is recommended for the bottom banner arm. • Banners not furnished by American Electric Lighting. EB/CO2(180)5 (EyeBolt /Clamp-On, 2 at 180 degrees, 5”0 post shaft See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 111 Heritage Series Flagpole Holders Cast Aluminum P R O D U C T O V E R V I E W 1" Flagpole Features: 3/4" Flagpole FPH3B FPH4B (holder for 1" pole with bolt-on mounting) 1-1/4" Flagpole (holder for 3/4" pole with bolt-on mounting) 1-1/2" Flagpole MATERIALS The flagpole holders shall be aluminum, ASTM 6061 alloy, heat treated to a T6 temper. All hardware shall be stainless steel. FPH6B FPH5B (holder for 1-1/4" pole with bolt-on mounting) INSTALLATION The flagpole holders shall bolt to a mounting channel on the side of the post with four stainless steel screws. The clamp-on mounting shall clamp around the post, secured with four 3/8” hex head bolts. (Post diameter at mounting point must be specified.) Holders are available for 3/4”, 1”, 1-1/4”, and 1-1/2” O.D. flag poles. For information on specifying orientation and mounting heights see Orientation Guide, page 130. (Flags and flag poles provided by others.) (holder for 1-1/2" pole with bolt-on mounting) CONSTRUCTION The flagpole holders shall be one-piece construction. The holders shall consist of a piece of aluminum tubing welded at 45° to a mounting plate. All welding shall be per ANSI/AWS D1.2-90. All welders shall be certified per ANSI/AWS D1.2-90 Section 5. Other Mounting Options Applications: 1" Flagpole Streetscapes Walkways Pathways Parks 3/4" Flagpole FPH4C19 (holder for 1" pole with clamp-on mounting) 1-1/4" Flagpole FPH3C19 (holder for 3/4" pole with clamp-on mounting) 1-1/2" Flagpole FPH5C19 (holder for 1-1/4" pole with clamp-on mounting) FPH6C19 (holder for 1-1/2" pole with clamp-on mounting) Notes: Flags can add substantial wind loading to the post you select. Please coordinate the correct post size and style with the factory. 112 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Heritage Series Flagpole Holders Cast Aluminum O R D E R I N G I N F O R M AT I O N Example F P H 4 C 1 9 FPHCD4 ANBK AEL AEL Flagpole Holders Bolt-on1 1”0 1-1/4”0 1-1/2”0 3/4”0 FPH3B FPH4B FPH5B FPH6B 2FPH3B 2FPH4B 2FPH5B 2FPH6B 3FPH3B 3FPH4B FPH5B 3FPH6B 4FPH3B 3FPH4B 3FPH5B 3FPH6B 3/4”0 FPH3C19 2FPH3C28 3FPH3C29 4FPH3C39 FPH3C49 Notes: 1 2 3 1 holder 2 holders 3 holders 4 holders Clamp-on 1”0 1-1/4”0 1-1/2”0 FPH4C19 FPH5C19 FPH6C19 2FPH4C28 2FPH5C28 2FPH6C28 3FPH4C29 3FPH5C29 3FPH6C29 4FPH4C39 4FPH5C39 4FPH6C39 FPH4C49 FPH5C49 FPH6C49 1 holder 2 holders @ 180 2 holders @ 90 3 holders @ 90 4 holders @ 90 FPH Clamp Dia. 2,3 (clamp-ons only) FPHCD3 3”0 FPHCD3-1/2 3-1/2”0 FPHCD4 4”0 FPHCD4-1/2 4-1/2”O FPHCD5 5”0 FPHCD5-1/2 5-1/2”0 FPHCD6 6”0 FPHCD6-1/2 6-1/2”0 FPHCD7 7”0 FPHCD7-1/2 7-1/2”O FPHCDTBS0 to be specified Manufacturing Code Finish3 ANBK ANDB ANDG ANVG ANPP CM CS AEL Black Dark Bronze Dark Green Verde Green Prime Painted Custom Match Custom Select RAL colors For information on specifying orientation and mounting heights, see Orientation Guide, page 130 For clamp dia., take post dia. and round up to the nearest 1/2" For finish and color options see, please contact your local AEL representative FPH3C29 Clamp-On Mounting Post Top Mounting Clamp with (4) 3/8" Hex Hd. Bolts to Clamp On Post (4) 1/4" Button Hd. Socket Screws to Post FPH4C19 FPHCDxx FPH4B Suggested Flagpole Usage orientation orientation FPH4B Flagpole holder, for 1”0 pole, bolt-on FPH4C28 FPHCD5 Flagpole holder, for 1”0, clamp-on with 2 holders at 180 degrees, clamp for 5”0 post. Notes: For holders for two (or more) poles with bolt-on mounting, add 2 or required number before the part number. orientation FPH4C29 FPHCD5 (Flagpole holder, for 1”0 pole, clamp-on with 2 holders at 90-degrees, clamp for a 5”0 post) orientation FPH4C29 FPHCD5 (Flagpole holder, for 1”0 pole, clamp-on with 4 holders at 90degrees, clamp for a 5”0 post) orientation Notes: * For information on specifying orientation and mounting heights, see Orientation Guide, page 130 • Flags not furnished by American Electric Lighting See pages 259-264 for a complete listing of Frequently Ordered Products FPH4C39 FPHCD5 (Flagpole holder, for 1”0 pole, clamp-on with 3 holders at 90 degrees, clamp for a 5”0 post) Product Guide 113 Heritage Series Street Signs Cast Aluminum Octagonal Frames P R O D U C T O V E R V I E W 5" 20" 3" x 18" Solid Sign Opening 6" x 35 1/2" Solid Sign Opening 8" 37.5" 37.5" (single sign frame w/ bolt-on mounting) (double sign frame w/ bolt-on mounting) SS1OB SS2OB Other Mounting Options (with post top mounting) (with clamp-on mounting) SS1OP SS1OC19 SSCDxx Features: INSTALLATION The bolt-on sign frame shall bolt to a mounting channel on the side of the post with four stainless steel screws. The clamp-on mounting shall clamp around the post, secured with four 3/8" hex head bolts. (Post dia. at mounting point must be specified.) The post top mounting shall fit on a 3" O.D. x 3" tall tenon with six 1/4" dia. socket set screws. (Lettering and graphics provided by others.) For information on specifying orientation and mounting heights, see Orientation Guide, page 130. MATERIALS The sign frame shall be heavy wall, copper free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B179-95a or ASTM B26-95. The mounting plate, post clamp, post top fitter, and banner arm shall be aluminum, ASTM 6061, heat treated to a T6 temper. All hardware shall be stainless steel. CONSTRUCTION The street sign frame shall be welded to a mounting plate, post clamp, or post top fitter. All welding shall be per ANSI/ AWS D1.2-90. All welders shall be certified per ANSI/AWS D1.2-90 Section 5. (hanging from banner arm with bolt-on mounting) (hanging from banner arm with clamp-on mounting) SS1OC19 SSCDxx SWBA SS1OB SWBA Decorative Options (Note: All decorative and mounting options available with single or double signs) DIMENSIONS Sign frame shall measure 37.5" wide and 8" tall with a 6" x 35.5" opening for graphics mounting. The optional smaller frame shall measure 20" wide and 5" tall with a 3" x 18" opening for graphics mounting. DESCRIPTION The street sign frame shall be a curved shaped, one-piece casting with a solid backing and a 1" thick border. The sign frame has an optional smaller top casting typically used for cross street name. The sign frame is identical on both sides. SS1OPAF (decorative finial) SS2OB SWS (decorative scroll) 114 Product Guide SS2OB SWBAS (decorative scroll on banner arm) For photometric information, please visit our website, www.americanelectriclighting.com Heritage Series Street Signs Cast Aluminum Octagonal Frames O R D E R I N G I N F O R M AT I O N Example: S S 1 O C 1 9 S S C D 4 S W B A A N B K A E L AEL Options SS Clamp Dia.2 Manufacturing Code (clamp-on only) (bolt-on & clamp- on only) Post Top SSCD3 3”O AEL SWS Sign w/ Scroll SS1OB Single Frame SS1OP Single Frame SSCD3-1/2 3-1/2”O SWBA Sign w/ Banner Arm SS2OB Double Frame SS2OP Double Frame SSCD4 4”O SWBAS Sign w/ Banner Arm 2SS1OB 2 Single Frames SS1OP29 2 Single Frames SSCD4-1/2 4-1/2”O and Scroll 2SS2OB 2 Double Frames @ 90 SSCD5 5”O SS1OPAF Single Frame SSCD5-1/2 5-1/2”O Finish Clamp-Ons w/Finial SSCD6 6”O SS1OC19 Single Frame SS2OPAF Double Frame ANBK Black SSCD6-1/2 6-1/2”O SS2OC19 Double Frame w/Finial ANDB Dark Bronze SSCD7 7”O SS1OC29 2 Single Frames @ 90 SS1OP29AF 2 Single Frames ANDG Dark Green SSCD7-1/2 7-1/2”O SS2OC29 2 Double Frames @ 90 @ 90 w/Finial ANVG Verde Green SSCDTBS 0 to be specified Notes: ANPP Prime Painted CM Custom Match 1 For information on specifying orientation and mounting heights see the Orientation Guide. CS Custom Select 2 For clamp dia, take post dia. and round up to the nearest 1/2". RAL colors Curved Street Sign Frames Bolt-Ons1 Bolt-On Mounting Clamp-On Mounting Clamp with (4) 3/8" Hex Hd. Bolts to Clamp On Post (4) Stainless Steel Screws to Post xx" SS1OC19 SSCDxx SS1OB Hanging with Bolt-On or Clamp-On Mounting Post Top Mounting (6) 1/4" Socket Set Screws (4) Stainless Steel Screws to Post (Also available with Clamp-On Mounting, see above and front page) Banner Arm (6) 1/4" Socket Set Screws Slip Fits 3" O.D. x 3" High Tenon SS1OB SWBA (Bolt-on) SS1OC19 SSCDxx SWBA (Clamp-on) SS1OP For Twin Signs (with Bolt-On mounting only) a 2 is added before the part no. (ie: 2SS1CB) Post Top Mounting Clamp-On Mounting Signs 90¡ 90¡ Signs Post Post SS1OC29 SSCDxx SS1OP29 See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 115 Heritage Series Street Signs Cast Aluminum Oval Frames P R O D U C T O V E R V I E W 5" 20" 3" x 18" Solid Sign Opening 6" x 35 1/2" Solid Sign Opening 8" 37.5" 37.5" SS1B SS2B (single sign frame w/ bolt-on mounting) (double sign frame w/ bolt-on mounting) Other Mounting Options SS1P SS1C19 SSCDxx (with post top mounting ) (with clamp-on mounting) Features: INSTALLATION The bolt-on sign frame shall bolt to a mounting channel on the side of the post with four stainless steel screws. The clamp-on mounting shall clamp around the post, secured with four 3/8" hex head bolts. (Post dia. at mounting point must be specified.) The post top mounting shall fit on a 3" O.D. x 3" tall tenon with six 1/4" dia. socket set screws. (Lettering and graphics provided by others.) For information on specifying orientation and mounting heights, see Orientation Guide, page 130. MATERIALS The sign frame shall be heavy wall, copper-free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B-17995a or ASTM B26-95. The mounting plate, post clamp, post top fitter and banner arm shall be aluminum, ASTM 6061, heat treated to a T6 temper. All hardware shall be stainless steel. CONSTRUCTION The street sign frame shall be welded to a mounting plate, post clamp or post top fitter. All welding shall be per ANSI/ AWS D1.290. All welders shall be certified per ANSI/AWS D1.2-90 Section 5. SS1C19 SSCDxx SWBA SS1B SWBA (hanging from banner arm with bolt-on mounting) (hanging from banner arm with clamp-on mounting) Decorative Options (Note: All decorative and mounting options available with single or double signs) SS1PAF (decorative finial) SS2B SWS (decorative scro ll) 116 Product Guide SS2B SWBAS (decorative scroll on banner arm) For photometric information, please visit our website, www.americanelectriclighting.com DIMENSIONS Sign frame shall measure 37.5" wide and 8" tall with a 6" x 35.5" opening for graphics mounting. The optional smaller frame shall measure 20" wide and 5" tall with a 3" x 18" opening for graphics mounting. DESCRIPTION The street sign frame shall be a curve shaped, one-piece casting with a solid backing and a 1" thick border. The sign frame has an optional smaller top casting typically used for cross street name. The sign frame is identical on both sides. Heritage Series Street Signs Cast Aluminum Oval Frames O R D E R I N G I N F O R M AT I O N Example: S S 1 C 1 9 S S C D 4 S W B A A N B K A E L AEL Options SS Clamp Dia.2 Curved Street Sign Frames (clamp-on only) (bolt-on & clamp- on only) SSCD3 3”O SWS Sign w/Scroll SS1B Single Frame Single Frame SSCD3-1/2 3-1/2”O SWBA Sign w/Banner Arm SS2B Double Frame Double Frame SSCD4 4”O SWBAS Sign w/Banner Arm 2SS1B 2 Single Frames 2 Single Frames SSCD4-1/2 4-1/2”O and Scroll 2SS2B 2 Double Frames @ 90 SSCD5 5”O SS1PAF Single Frame SSCD5-1/2 5-1/2”O Clamp-Ons w/ Finial ANBK SSCD6 6”O SS1C19 Single Frame SS2PAF Double Frame ANDB SSCD6-1/2 6-1/2”O SS2C19 Double Frame w/ Finial ANDG SSCD7 7”O SS1C29 2 Single Frames @ 90 SS1P29AF 2 Single Frames ANVG SSCD7-1/2 7-1/2”O SS2C29 2 Double Frames @ 90 @ 90 w/ Finial ANPP SSCDTBS 0 to be specified Notes: CM 1 For information on specifying orientation and mounting heights see Orientation Guide, page 130 CS 2 For clamp dia., take post dia. and round up to the nearest 1/2" Bolt-Ons1 Manufacturing Code Post Top SS1P SS2P SS1P29 Bolt-On Mounting AEL Finish Black Dark Bronze Dark Green Verde Green Prime Painted Custom Match Custom Select RAL colors Clamp-On Mounting Clamp with (4) 3/8" Hex Hd. Bolts to Clamp On Post (4) Stainless Steel Screws to Post xx" SS1C19 SSCDxx SS1B Hanging with Bolt-On or Clamp-On Mounting Post Top Mounting (6) 1/4" Socket Set Screws (4) Stainless Steel Screws to Post (Also available with Clamp-On Mounting, see above and front page) Banner Arm (6) 1/4" Socket Set Screws Slip Fits 3" O.D. x 3" High Tenon SS1B SWBA (Bolt-On) SS1C19 SSCDxx SWBA (Clamp-On) SS1P For Twin Signs (with Bolt-On mounting only) a 2 is added before the part no. (ie: 2SS1CB) Post Top Mounting Clamp-On Mounting Signs 90¡ 90¡ Signs Post Post SS1C29 SSCDxx SS1P29 See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 117 Heritage Series Street Signs Cast Aluminum Rectangular Frames P R O D U C T O V E R V I E W 5" 20" 3" x 18" Solid Sign Opening 6" x 35 1/2" Solid Sign Opening 8" 37.5" 37.5" (single sign frame w/ bolt-on mounting) (double sign frame w/ bolt-on mounting) SS2RB SS1RB Features: INSTALLATION The bolt-on sign frame shall bolt to a mounting channel on the side of the post with four stainless steel screws. The clamp-on mounting shall clamp around the post, secured with four 3/8" hex head bolts. (Post dia. at mounting point must be specified.) The post top mounting shall fit on a 3" O.D. x 3" tall tenon with six 1/4" dia. socket set screws. (Lettering and graphics provided by others) For information on specifying orientation and mounting heights, see Orientation Guide, page 130. MATERIALS The sign frame shall be heavy wall, copper-free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B-179-95a or ASTM B26-95. The mounting plate, post clamp, post top fitter and banner arm shall be aluminum, ASTM 6061, heat treated to a T6 temper. All hardware shall be stainless steel. Other Mounting Options (with post top mounting) (with clamp-on mounting) SS1RC19 SSCDxx SS1RP CONSTRUCTION The street sign frame shall be welded to a mounting plate, post clamp or post top fitter. All welding shall be per ANSI/ AWS D1.2-90. All welders shall be certified per ANSI/AWS D1.2-90 Section 5. DIMENSIONS Sign frame shall measure 37.5" wide and 8" tall with a 6" x 35.5" opening for graphics mounting. The optional smaller frame shall measure 20" wide and 5" tall with a 3" x 18" opening for graphics mounting. (hanging from banner arm with bolt-on mounting) (hanging from banner arm with clamp-on mounting) SS1RB SWBA SS1RC19 SSCDxx SWBA Decorative Options (Note: All decorative and mounting options available with single or double signs) DESCRIPTION The street sign frame shall be a curve shaped, one-piece casting with a solid backing and a 1" thick border. The sign frame has an optional smaller top casting typically used for cross street name. The sign frame is identical on both sides. (decorative finial) SS1RPAF SS2RB SWS 118 Product Guide SS2RB SWBAS For photometric information, please visit our website, www.americanelectriclighting.com Heritage Series Street Signs Cast Aluminum Rectangular Frames O R D E R I N G I N F O R M AT I O N Example: S S 1 R C 1 9 S S C D 4 S W B A A N B K A E L AEL SS Clamp Dia.2 Options Manufacturing Code (clamp-on only) (bolt-on & clamp- on only) Post Top SSCD3 3”O AEL SWS Sign w/ Scroll SS1RB Single Frame SSR1P Single Frame SSCD3-1/2 3-1/2”O SWBA Sign w/ Banner Arm SS2RB Double Frame SSR2P Double Frame SSCD4 4”O SWBAS Sign w/ Banner Arm 2SS1RB 2 Single Frames SS1RP29 2 Single Frames SSCD4-1/2 4-1/2”O and Scroll 2SS2RB 2 Double Frames @ 90 SSCD5 5”O SS1RPAF Single Frame Finish SSCD5-1/2 5-1/2”O Clamp-Ons w/ Finial ANBK Black SSCD6 6”O SS1RC19 Single Frame SS2RPAF Double Frame ANDB Dark Bronze SSCD6-1/2 6-1/2”O SS2RC19 Double Frame w/ Finial ANDG Dark Green SSCD7 7”O SS1RC29 2 Single Frames @ 90 SS1RP29AF 2 Single Frames@ ANVG Verde Green SSCD7-1/2 7-1/2”O SS2RC29 2 Double Frames @ 90 90 w/ Finial ANPP Prime Painted SSCDTBS 0 to be specified Notes: CM Custom Match CS Custom Select 1 For information on specifying orientation and mounting heights see Orientation Guide, page 130 RAL colors 2 For clamp dia., take post dia. and round up to the nearest 1/2" Curved Street Sign Frames Bolt-Ons1 Bolt-On Mounting Clamp-On Mounting Clamp with (4) 3/8" Hex Hd. Bolts to Clamp On Post (4) Stainless Steel Screws to Post xx" SS1RB SS1RC19 SSCDxx Hanging with Bolt-On or Clamp-On Mounting Post Top Mounting (6) 1/4" Socket Set Screws (4) Stainless Steel Screws to Post (Also available with Clamp-On Mounting, see above and front page) Banner Arm (6) 1/4" Socket Set Screws Slip Fits 3" O.D. x 3" High Tenon SS1RP SS1RB SWBA (Bolt-on) SS1RC19 SSCDxx SWBA (Clamp-on) For Twin Signs (with Bolt-On mounting only) a 2 is added before the part no. (ie: 2SS1CB) Post Top Mounting Clamp-On Mounting SS1RC29 SSCDxx SS1RP29 Signs 90¡ 90¡ Signs Post See pages 259-264 for a complete listing of Frequently Ordered Products Post Product Guide 119 Heritage Series Street Signs Cast Aluminum Curved Frames P R O D U C T O V E R V I E W Features: 5" 20" 3" x 18" Solid Sign Opening 6" x 35 1/2" Solid Sign Opening 8" 37.5" 37.5" (single sign frame w/ bolt-on mounting) (double sign frame w/ bolt-on mounting) SS1CB SS2CB MATERIALS The sign frame shall be heavy wall, copper-free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B179-95a or ASTM B26-95. The mounting plate, post clamp, post top fitter and banner arm shall be aluminum, ASTM 6061, heat treated to a T6 temper. All hardware shall be stainless steel. Other Mounting Options (with post top mounting ) SS1CP (with clamp-on mounting) SS1CC19 SSCDxx (hanging from banner arm with bolt-on mounting) (hanging from banner arm with clamp-on mounting) SS1CB SWBA SS1CC19 SSCDxx SWBA Decorative Options (Note: All decorative and mounting options available with single or double signs) (decorative finial) SS1CPAF (decorative scro ll) SS2CB SWS 120 Product Guide INSTALLATION The bolt-on sign frame shall bolt to a mounting channel on the side of the post with four stainless steel screws. The clamp-on mounting shall clamp around the post, secured with four 3/8" hex head bolts. (Post dia. at mounting point must be specified.) The post top mounting shall fit on a 3" O.D. x 3"tall tenon with six 1/4" dia. socket set screws. (Lettering and graphics provided by others.) For information on specifying orientation and mounting heights, see Orientation Guide, page 130. (decorative scroll on banner arm) SS2CB SWABS For photometric information, please visit our website, www.americanelectriclighting.com CONSTRUCTION The street sign frame shall be welded to a mounting plate, post clamp or post top fitter. All welding shall be per ANSI/ AWS D1.2-90. All welders shall be certified per ANSI/AWS D1.2-90 Section 5. DIMENSIONS Sign frame shall measure 37.5" wide and 8" tall with a 6" x 35.5" opening for graphics mounting. The optional smaller frame shall measure 20" wide and 5" tall with a 3" x 18" opening for graphics mounting. DESCRIPTION The street sign frame shall be a curve shaped, one-piece casting with a solid backing and a 1" thick border. The sign frame has an optional smaller top casting typically used for cross street name. The sign frame is identical on both sides. Heritage Series Street Signs Cast Aluminum Curved Frames O R D E R I N G I N F O R M AT I O N Example: S S 1 C C 1 9 S S C D 4 S W B A A N B K A E L AEL Curved Street Sign Frames Options Manufacturing Code (clamp-on only) (bolt-on & clamp- on only) SSCD3 3”O Single Frame Single Frame AEL SWS Sign w/ Scroll SSCD3-1/2 3-1/2”O Double Frame Double Frame SWBA Sign w/ Banner Arm SSCD4 4”O 2 Single Frames 2 Single Frames SWBAS Sign w/ Banner Arm SSCD4-1/2 4-1/2”O 2 Double Frames @ 90 and Scroll SSCD5 5”O SS1CPAF Single Frame Finish SSCD5-1/2 5-1/2”O Clamp-Ons w/ Finial SSCD6 6”O ANBK Black SS1CC19 Single Frame SS2CPAF Double Frame SSCD6-1/2 6-1/2”O ANDB Dark Bronze SS2CC19 Double Frame w/ Finial SSCD7 7”O ANDG Dark Green SS1CC29 2 Single Frames @ 90 SS1CP29AF 2 Single Frames SSCD7-1/2 7-1/2”O ANVG Verde Green SS2CC29 2 Double Frames @ 90 @ 90 w/ Finial SSCDTBS 0 to be specified ANPP Prime Painted CM Custom Match Notes: CS Custom Select 1 For information on specifying orientation and mounting heights see Orientation Guide, page 130 RAL colors 2 For clamp dia, take post dia. and round up to the nearest 1/2" Bolt-ons1 SS1CB SS2CB 2SS1CB 2SS2CB SS Clamp Dia.2 Post Top SS1CP SS2CP SS1CP29 Bolt-On Mounting Clamp-On Mounting Clamp with (4) 3/8" Hex Hd. Bolts to Clamp On Post xx" (4) Stainless Steel Screws to Post SS1CC19 SSCDxx SS1CB Post Top Mounting Hanging with Bolt-On or Clamp-On Mounting (6) 1/4" Socket Set Screws (4) Stainless Steel Screws to Post (Also available with Clamp On Mounting, see above and front page) Banner Arm (6) 1/4" Socket Set Screws Slip Fits 3" O.D. x 3" High Tenon SS1CP SS1CB SWBA (Bolt-on) SS1CC19 SSCDxx SWBA (Clamp-on) For Twin Signs (with Bolt-On mounting only) a 2 is added before the part no. (ie: 2SS1CB) Post Top Mounting Clamp-On Mounting SS1CP29 Signs SS1CC29 SSCDxx 90° 90° Signs Post See pages 259-264 for a complete listing of Frequently Ordered Products Post Product Guide 121 Heritage Series Ladder Rests Cast Aluminum P R O D U C T O V E R V I E W Features: 1" INSTALLATION The ladder rest shall mount on a 3” O.D. tenon, below the luminaire, with four 1/4” diameter socket set screws. MATERIALS The ladder rests shall be heavy wall, copper-free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B-179-95A or ASTM B26-95. All hardware shall be stainless steel. 16" LRD CONSTRUCTION The ladder rests shall be one-piece cast aluminum construction. The castings are decorative replicas of ladder rests used on posts with gas lamps. 1" DIMENSIONS The ladder rest shall have a 1” tall mounting height with either a 16” or 17.5”span. Applications: 17.5" LRT Streetscapes Walkways Pathways Parks 3" O.D . Tenon (4)1 /4 " Socket Set Screws post # luminaire # LRT (post and luminaire with ladder rest) 122 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Heritage Series Medium Post Top Finials Tenon Cast Aluminum O R D E R I N G I N F O R M AT I O N Features: INSTALLATION The finials shall mount to a post top tenon using stainless steel socket set screws. MATERIALS The finial castings shall be heavy-wall, copper free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B-179-95a or ASTM B26-95. The tubing shall be aluminum, ASTM 6061 alloy, heat treated to a T6 temper. All hardware shall be stainless steel. 23 " 21 " 6.25 " 5" CH F LBF CONSTRUCTION The finials shall be one-piece construction. The finials shall consist of a one-piece casting or a casting welded to a piece of aluminum tubing. All welding shall be per ANSI/AWS D1.2-90. All welders shall be certified per ANSI/AWS D1.2-90 Section 5. Applications: Streetscapes Walkways Pathways Parks 15" 14.5" 12 " 6.25 " 6.25 " 6.25 " BF/MT PF/MT FF/ MT Example: B F / M T U A N B K A E L AEL Series 22" 21.5" 19" 7" 7" 7" BF/MTU PF/MTU FF/ MTU CHF LBF BF/MT PF/MT FF/MT BF/MTU PF/MTU FF/MTU BF/MTD PF/MTD FF/MTD Finish1 ANBK ANDB ANDG ANVG ANPP CM CS Black Dark Bronze Dark Green Verde Green Prime Painted Custom Match Custom Select RAL colors Manf. Code AEL Notes: 1 For finish specifications and color options, please contact your local AEL representative 22" 21.5" 19 " 9" 9" 9" BF/M TD PF/MTD FF/ MTD See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 123 Heritage Series Large Post Top Finials Tenon Cast Aluminum P R O D U C T O V E R V I E W Features: 18 " 16 " 14 " INSTALLATION The finials shall mount to a post top tenon using stainless steel socket set screws. 7.5" 7.5" 9.25 " BRF PRF FR F CONSTRUCTION The finials shall be one-piece construction. The finials shall consist of a onepiece casting or a casting welded to a piece of aluminum tubing. All welding shall be per ANSI/AWS D1.2-90. All welders shall be certified per ANSI/AWS D1.2-90 Section 5. 21" 19.5" 17.5" MATERIALS The finial castings shall be heavywall, copper-free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B-179-95a or ASTM B26-95. The tubing shall be aluminum, ASTM 6061 alloy, heat treated to a T6 temper. All hardware shall be stainless steel. Applications: 9.75 " 9.75 " 9.75 " BRF/LT PRF/ LT FR F/ LT Streetscapes Walkways Pathways Parks Example: B R F / L T U A N B K A E L AEL Series 11" 11 " 11 " BRF/L TU PRF/ LTU FR F/LTU 14" 14 " 14" BRF/L TD PRF/ LTD FR F/ LTD Product Guide BRF PRF FRF BRF/LT PRF/LT FRF/LT BRF/LTU PRF/LTU FRF/LTU BRF/LTD PRF/LTD FRF/LTD 31.5" 30" 28" 124 31.5" 30 " 28 " For photometric information, please visit our website, www.americanelectriclighting.com Finish1 ANBK ANDB ANDG ANVG ANPP CM CS Black Dark Bronze Dark Green Verde Green Prime Painted Custom Match Custom Select RAL colors Manf. Code AEL Notes: 1 For finish specifications and color options, please contact your local AEL representative Heritage Series Small Post Top Finials Cast Aluminum P R O D U C T O V E R V I E W Features: 12" 7.5" 10" INSTALLATION The finials shall mount to a post top tenon using stainless steel socket set screws. 10" 3.5" 3.5" 3.5" SBF NAF ASF 8" 8" MATERIALS The finial castings shall be heavy-wall, copper-free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B-179-95a or ASTM B2695. The tubing shall be aluminum, ASTM 6061 alloy, heat treated to a T6 temper. All hardware shall be stainless steel. CONSTRUCTION The finials shall be one-piece construction. The finials shall consist of a one-piece casting or a casting welded to a piece of aluminum tubing. All welding shall be per ANSI/AWS D1.2-90. All welders shall be certified per ANSI/AWS D1.2-90 Section 5. 8" 4" 4.5" 4.5" 4.5" SC F MBF CCF OMF Applications: Streetscapes Walkways Pathways Parks 15 " 12" 11.5 " Example: W F A N B K A E L 8.5" 4.5" 4.5" 4.5" 4.5" RWF TMF TLF FMF 12 " 11.5 " 9.5" 9" 4.5" 5" 5" 5" WF BF OT F ELF Series SBF NAF ASF SCF MBF CCF OMF RWF TMF TLF FMF WF BF OTF ELF FF PF KWF WLF Finish1 ANBK ANDB ANDG ANVG ANPP CM CS Black Dark Bronze Dark Green Verde Green Prime Painted Custom Match Custom Select RAL colors Manf. Code AEL Notes: 1 For finish specifications and color options, please contact your local AEL representative 16.5 " 15.5 " 12 " AEL 12 " 5" 5" 5" 5" FF PF KWF WLF See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 125 Heritage WTA Series Crossarms and Wall Bracket Cast Aluminum P R O D U C T O V E R V I E W Features: INSTALLATION The crossarms shall slip-fit a post top tenon and attach with socket set screws. The center finial shall be removable. The wall bracket shall have four 9/16” dia. holes for mounting to the wall. (Bracket mounting hardware furnished by others.) Both crossarms and wall bracket shall have 3”O.D. tenons for luminaire mounting. MATERIALS The arm assemblies shall be heavy-wall, copper free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B-179-95a or ASTM B26-95. The center luminaire extension piece and wall bracket mounting plate shall be aluminum, ASTM 6061 alloy, heat treated to a T6 temper. All hardware shall be stainless steel. All exterior hardware shall be tamper resistant. O R D E R I N G CONSTRUCTION The crossarms and wall brackets shall be one-piece construction. For wall brackets, the arm shall be welded to a flat wall plate. All welding shall be per ANSI/AWS D1.2-90. All welders shall be certified per ANSI/AWS D1.2-90 Section 5. Applications: Streetscapes Walkways Pathways Parks I N F O R M AT I O N AEL Finish1 Series WTAWB WTA2 WTA28/2T WTA28/4 WTA28/4T 126 One Two Three Four Five Product Guide ANBK ANDB ANDG ANVG ANPP CM CS Example: W T A 2 8 / 2 T A N B K A E L Manufacturing Code Black Dark Bronze Dark Green Verde Green Prime Painted Custom Match Custom Select RAL colors AEL Notes: 1 For finish specifications and color options, please contact your local AEL representative For photometric information, please visit our website, www.americanelectriclighting.com Heritage WTA Series Crossarms and Wall Bracket Cast Aluminum P R O D U C T 14" 3" O.D. x 3" high Tenon (typical) 8" O V E R V I E W orientation 11.5" 9.5" x 13" Wall Bracket Mounting Plate (4) 9/16" ¯ Holes WTAWB (one-way wall mount) orientation orientation 27.5" 13.75" Varies with Luminaire Center Finial 22" WTA28 WTA28/2 T (two at 180 ) (two at 180 w/ one at center) (Note: Dimensions typical for all WTA Series). Center Tenon Center Finial orientation orientation WTA28/4 WTA28/4 T (four at 90 ) (four at 90 w/one at center) See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 127 Heritage OS Series Crossarms and Wall Bracket Cast Aluminum P R O D U C T O V E R V I E W Features: INSTALLATION The crossarms shall slip-fit a 3" O.D.x 5" post top tenon and attach with socket set screws. The center finial shall be removable. The wall bracket shall have four 9/16” dia. holes for mounting to the wall. (Bracket mounting hardware furnished by others.) Both crossarms and wall bracket shall have 3” O.D. tenons for luminaire mounting. CONSTRUCTION The crossarms and wall brackets shall be one-piece construction. The arms shall be welded to a center spool. For wall brackets the arm shall be welded to a flat wall plate. All welding shall be per ANSI/AWS D1.2-90. All welders shall be certified per ANSI/AWS D1.2-90 Section 5. MATERIALS The arms, finials, and tenons, shall be heavy-wall, copper free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B-179-95a or ASTM B26-95. The center spool and wall bracket mounting plate shall be aluminum, ASTM 6061 alloy, heat treated to a T6 temper. All hardware shall be stainless steel. All exterior hardware shall be tamper resistant. Applications: O R D E R I N G Streetscapes Walkways Pathways Parks I N F O R M AT I O N AEL Series OSWB OS26 OS26/2T OS26/3 OS26/3T OS26/4 OS26/4T 128 One Two Three Three Four Four Five Product Guide Finish2 ANBK ANDB ANDG ANVG ANPP CM CS Example: O S 2 6 / 2 T A N B K A E L Manufacturing Code Black Dark Bronze Dark Green Verde Green Prime Painted Custom Match Custom Select RAL colors AEL Notes: 1 For finish specifications and color options, please contact your local AEL representative For photometric information, please visit our website, www.americanelectriclighting.com Heritage OS Series Crossarms and Wall Bracket Cast Aluminum P R O D U C T 3" O .D . x 3 " high Tenon (typical) 4.5" O V E R V I E W 11.5" orientation 6" x 8 " Wall Bracket Mounting plate 6.5" (4 ) 9/16" Ø Holes OSWR (one -way wall mount) orientation orientation 26" Varies with Luminaire Center Finial 11" OS26 (two at 180˚) orientation (N ot e: Dimensions typical for all OS Series). OS26/2T (two at 180 ˚ w/ one at center ) orientation 23" OS26/3 OS26/3T (three at 120 ˚ w/ one at cent er ) (three at 120 ˚ ) orientation orientation OS26/4 (four at 90˚) OS26/4T (four at 90˚ w/ one at center ) See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 129 Heritage Series Orientation Guide P R O D U C T O V E R V I E W Features: This guide is to help plan the correct orientation of signs and accessories on the post. To facilitate correct orientation on a project, careful planning and coordination with the factory is required. Below is an illustration of a sample post with multiple accessories showing the orientation in relationship to the post door and the street. Below is a sample sketch used to show the part number, mounting height, and orientation degrees for each accessory. The illustration of the post base plan view shows the orientation of the parts in relationship to the post door and anchor bolts. Street Sign SS1B 0¡ Part # Height Orientation FG-S 15’-6” 0 degrees SS1B 14’-0” 180 degrees SS1B 14’-0” 270 degrees BA24H/1/BO 13’-0” 90 degrees FPH4B 11’-6” 0 degrees 10’-0” 90 degrees Weatherproof Receptacle FG-S 180¡ 270¡ Street Sign SS1B 90¡ Banner Arm BA24H/1/BO Flagpole holder FPH4B 0¡ BA24H/1/BO Banner Arm BA24H/1/BO 90¡ Post Elevation 10 ’0” height from bottom of post Post Base Plan View Street sign Curb 180¡ 225¡ Anchors Street 10’ 0” min. height recommended for banner arms Sign 135¡ 270¡ 90¡ 45¡ 315¡ 0 degrees Base door Banner Door 0¡ Receptacle and flagpole 130 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Heritage Series Orientation Guide P R O D U C T O V E R V I E W Below is a blank sketch to record the part #, mounting height and orientation degrees for your post accessories. Copy and paste your post base plan view in the appropriate space below. Part # Height Orientation Accessory Center Post Elevation Post Base Plan View See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 131 Decorative Post Top Lighting B A L L A S T M AT R I C E S Marietta Series LMD Watts 120 03S RN 05S RH,RN 05M XH 07S RN, RH, CA, CT 07M XH 10S RH, RN,CA,CT 10V XN, CA 10M CA, XH 15S RH,RN,CA 15M XH 17V CA, XN 17M CA 25S CA 25V CA 25M CA 208 XH, XN XH XN, XH, CA, CT XH XN, XH, CA, CT CA XH XN, XH, CA XH CA CA CA 240 XH, XN XH XN, XH, CA, CT XH XN, XH, CA, CT CA XH XN, XH, CA XH CA CA CA CA 277 XH, XN XH, XN, XH, CA XH XN, XH, CA CA CA, XH XN, XH, CA XH CA CA CA CA 480 CA CA CA - DT1 XH, XN XN, XH, CA XN, XH, CA CA XH XN, XH, CA XH CA CA CA DT2 XH, XN XN, XH, CA XN, XH, CA CA XH XN, XH, CA XH CA CA CA MT1 XH,XN XH XN,XH, CA XH CA,XN,XH CA XH XH,XN,CA XH CA CA CA,CT CA MT2 XH,XN XH XN,XH, CA XH CA, XN,XH CA XH XH,XN, CA XH CA CA CA,CT CA MT7 XH,XN XH XN,XH, CA XH CA,XN,XH CA XH XH,XN, CA XH CA CA CA,CT CA Marietta Series LMD, Continued Watts 03S 05S 05M 07S 07M 10S 10V 10M 15S 15M 17V 17M 25S 25V 25M TT1 XN, XH XN, XH XN, XH XN, XH CA CA TT7 XN, XH XN, XH XN, XH XN, XH CA CA TT3 XN, XH XN, XH XN, XH XN, XH CA CA 347 XN, XH, CA, CT XN, XH XN, XH XN, XH, CA CA CA CA Sumter Series LSH Watts 120 03S RN 05S RH,RN 05M XH 07S RN, RH, CA, CT 07M XH 10S RH, RN,CA,CT 10V XN, CA 10M CA, XH 15S RH,RN,CA 15M XH 17V CA, XN 17M CA 25S CA 25V CA 25M CA 208 XH, XN XH XN, XH, CA, CT XH XN, XH, CA, CT CA XH XN, XH, CA XH CA CA CA CA CA 240 XH, XN XH XN, XH, CA, CT XH XN, XH, CA, CT CA XH XN, XH, CA XH CA CA CA CA CA 277 XH, XN XH, XN, XH, CA, CT XH XN, XH, CA CA CA, XH XN, XH, CA XH CA CA CA CA CA 480 CA X CA CA CA CA CA CA CA DT1 XH, XN XN, XH, CA XN, XH, CA CA XH XN, XH, CA XH CA CA CA CA CA DT2 XH, XN XN, XH, CA XN, XH, CA CA XH XN, XH, CA XH CA CA CA CA CA MT1 XH,XN XH XN,XH, CA XH CA,XN,XH CA XH XH,XN,CA XH CA CA CA CA,CT CA Sumter Series LSH, Continued Watts 03S 05S 05M 07S 07M 10S 10V 10M 15S 15M 17V 17M 25S 25V 25M 132 MT7 XH,XN XH XN,XH, CA XH CA,XN,XH CA XH XH,XN, CA XH CA CA CA CA,CT CA MT8 XH,XN XH XN,XH, CA XH CA,XN,XH CA XH XH,XN,CA XH CA CA CA CA,CT CA Product Guide TT1 XN, XH XN, XH XN, XH XN, XH CA CA TT7 XN, XH XN, XH XN, XH XN, XH CA CA TT3 XN, XH XN, XH XN, XH XN, XH CA CA 347 XN, XH, CA, CT XN, XH XN, XH XN, XH, CA CA CA CA For photometric information, please visit our website, www.americanelectriclighting.com MT2 XH,XN XH XN,XH, CA XH CA, XN,XH CA XH XH,XN, CA XH CA CA CA CA,CT CA MT8 XH,XN XH XN,XH, CA XH CA,XN,XH CA XH XH,XN,CA XH CA CA CA,CT CA Decorative Post Top Lighting B A L L A S T M AT R I C E S Cresthill Series LCR - Classic, Sphere, Centennial, and Glass Watts 03S 05S 05M 07S 07M 10S 10V 10M 15S 15M 17V 17M 25S 25V 25M 120 RN RH,RN XH RN, RH,CA,CT XH RH, RN,CA,CT XN, CA CA, XH RH,RN,CA XH CA, XN CA CA CA CA 208 XH, XN XH XN, XH,CA,CT XH XN, XH, CA, CT CA XH XN, XH, CA XH CA CA CA CA CA 240 XH, XN XH XN, XH,CA,CT XH XN, XH, CA, CT CA XH XN, XH, CA XH CA CA CA CA CA 277 XH, XN XH, XN, XH, CA XH XN, XH, CA CA CA, XH XN, XH, CA XH CA CA CA CA CA 480 CA CA CA CA CA CA CA CA DT1 XH, XN XN, XH,CA XN, XH, CA CA XH XN, XH, CA XH CA CA CA CA CA DT2 XH, XN XN, XH, CA XN, XH, CA CA XH XN, XH, CA XH CA CA CA CA CA MT1 -XH,XN XH XN,XH,CA XH CA,XN,XH CA XH XH,XN,CA XH CA CA CA CA,CT CA MT2 XH,XN XH XN,XH,CA XH CA, XN,XH CA XH XH,XN, CA XH CA CA CA CA,CT CA MT7 XH,XN XH XN,XH,CA XH CA,XN,XH CA XH XH,XN, CA XH CA CA CA CA,CT CA MT8 XH,XN XH XN,XH,CA XH CA,XN,XH CA XH XH,XN,CA XH CA CA CA CA,CT CA Cresthill Series LCR - Classic, Sphere, Centennial, and Glass, Continued Watts 03S 05S 05M 07S 07M 10S 10V 10M 15S 15M 17V 17M 25S 25V 25M TT1 XN,XH XN,XH XN,XH XN,XH CA CA TT2 XN,XH XN,XH XN,XH XN,XH CA CA TT3 XN,XH XN,XH XN,XH XN,XH CA CA 347 XN,XH,CA,CT XN,XH XN,XH XN,XH,CA CA CA CA Lexington LLX Watts 03S 05S 05M 07S 07M 10S 10V 10M 15S 15M 17V 17M 25S 25V 25M 120 RN RH, RN XH RN, RH XH RH, RN, CA, XN, CA CA, XH RH, RN, CA XH CA, XN CA CA CA CA 208 XH, XN XH XN, XH XH XN, XH, CA CA XH XN, XH, CA XH CA CA CA 240 XH, XN XH XN, XH XH XN, XH, CA CA XH XN, XH, CA XH CA CA CA CA 277 XH, XN XH, XN, XH XH XN, XH, CA CA CA, XH XN, XH, CA XH CA CA CA CA 480 CA CA - DT1 XH, XN XN, XH XN, XH, CA CA XH XN, XH, CA XH CA CA CA DT2 XH, XN XN, XH XN, XH, CA CA XH XN, XH, CA XH CA CA CA MT1 XH, XN XH XN, XH XH CA, XN, XH CA XH XH, XN, CA XH CA CA CA CA MT2 XH, XN XH XN, XH XH CA, XN, XH CA XH XH, XN, CA XH CA CA CA CA MT7 XH, XN XH XN, XH XH CA, XN, XH CA XH XH, XN, CA XH CA CA CA CA MT8 XH, XN XH XN, XH XH CA, XN, XH CA XH XH, XN, CA XH CA CA CA CA Lexington LLX, Continued Watts 03S 05S 05M 07S 07M 10S 10V 10M 15S 15M 17V 17M 25S 25V 25M TT1 XN, XH XN, XH XN, XH XN, XH CA CA TT7 XN, XH XN, XH XN, XH XN, XH CA CA TT3 XN, XH XN, XH XN, XH XN, XH CA CA 347 XN, XH, CA, CT XN, XH XN, XH XN, XH, CA CA CA CA See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 133 Decorative Post Top Lighting L AU SC TT M S PB RA OL D O VA ET R VI CI E W Syracuse LSY Watts 03S 05S 05M 07S 07M 10S 10V 10M 15S 15M 17V 17M 25S 25V 25M 120 RN RH, RN XH RN, RH XH RH, RN, CA, CT XN, CA CA, XH RH, RN, CA XH CA, XN CA CA CA CA 208 XH, XN XH XN, XH XH XN, XH, CA, CT CA XH XN, XH, CA XH CA CA CA 240 XH, XN XH XN, XH XH XN, XH, CA, CT CA XH XN, XH, CA XH CA CA CA CA 277 XH, XN XH, XN, XH XH XN, XH, CA CA CA, XH XN, XH, CA XH CA CA CA CA 480 CA CA - DT1 XH, XN XN, XH XN, XH, CA CA XH XN, XH, CA XH CA CA CA DT2 XH, XN XN, XH XN, XH, CA CA XH XN, XH, CA XH CA CA CA MT1 XH, XN XH XN, XH XH CA, XN, XH CA XH XH, XN, CA XH CA CA CA, CT CA MT2 XH, XN XH XN, XH XH CA, XN, XH CA XH XH, XN, CA XH CA CA CA, CT CA MT7 XH, XN XH XN, XH XH CA, XN, XH CA XH XH, XN, CA XH CA CA CA, CT CA MT8 XH, XN XH XN, XH XH CA, XN, XH CA XH XH, XN, CA XH CA CA CA, CT CA Syracuse LSY, Continued Watts 03S 05S 05M 07S 07M 10S 10V 10M 15S 15M 17V 17M 25S 25V 25M TT1 XN, XH XN, XH XN, XH XN, XH CA CA TT7 XN, XH XN, XH XN, XH XN, XH CA CA TT3 XN, XH XN, XH XN, XH XN, XH CA CA 347 XN, XH, CA, CT XN, XH XN, XH XN, XH, CA CA CA CA Victorian Series LVI Watts 03S 05S 05M 07S 07M 10S 10V 10M 15S 15M 17V 17M 25S 25V 120 RN RH,RN XH RN, RH,CA,CT XH RH, RN,CA,CT XN, CA CA, XH RH,RN,CA XH CA, XN CA CA CA 208 XH, XN XH XN, XH,CA,CT XH XN, XH, CA, CT CA XH XN, XH, CA XH CA CA CA CA 240 XH, XN XH XN, XH,CA,CT XH XN, XH, CA, CT CA XH XN, XH, CA XH CA CA CA CA 277 XH, XN XH, XN, XH, CA XH XN, XH, CA CA CA, XH XN, XH, CA XH CA CA CA CA 480 CA CA CA CA CA CA CA DT1 XH, XN XN, XH,CA XN, XH, CA CA XH XN, XH, CA XH CA CA CA CA DT2 XH, XN XN, XH, CA XN, XH, CA CA XH XN, XH, CA XH CA CA CA CA MT1 XH,XN XH XN,XH,CA XH CA,XN,XH CA XH XH,XN,CA XH CA CA CA CA,CT MT2 XH,XN XH XN,XH,CA XH CA, XN,XH CA XH XH,XN, CA XH CA CA CA CA,CT MT7 XH,XN XH XN,XH,CA XH CA,XN,XH CA XH XH,XN, CA XH CA CA CA CA,CT MT8 XH,XN XH XN,XH,CA XH CA,XN,XH CA XH XH,XN,CA XH CA CA CA CA,CT 25M CA CA CA CA CA CA CA CA CA CA CA Victorian Series LVI, Continued Watts 03S 05S 05M 07S 07M 10S 10V 10M 15S 15M 17V 17M 25S 25V 25M 134 TT1 XN,XH RXN,XH XN,XH XN,XH CA CA TT2 XN,XH XN,XH XN,XH XN,XH CA CA Product Guide TT3 XN,XH XN,XH XN,XH XN,XH CA CA 347 XN,XH,CA,CT XN,XH XN,XH XN,XH,CA CA CA CA For photometric information, please visit our website, www.americanelectriclighting.com Decorative Post Top Lighting O R D E RB IANL GL AI SN TF OMR AMT AR TI IC OE NS Yorktown LYT Watts 03S 05S 05M 07S 07M 10S 10V 10M 15S 15M 17V 17M 25S 25V 25M 120 RN RH,RN RN,CA XN,XH RH,RN,CA XN,CA CA RN,CA XN,XH - 208 CA CA - 240 XH,XN XH - 277 CA CA - 480 CA CA - MT1 XH,XN XH XN,XH XH CA,XN,XH CA CA,XH XH,XN,CA XH CA CA CA,XN,XH CA CA,XH MT2 XH,XN XH XN,XH XH XN,XH CA XH XH,XN XH CA CA XN,XH CA XH MT7 XH,XN XH XN,XH XH XN,XH CA XH XH,XN XH CA CA XN,XH CA XH MT8 XH,XN XH XN,XH XH XN,XH CA XH XH,XN XH CA CA XN,XH CA XH Branson LBR Watts 120 03S RN 05S RH,RN 05M XH 07S RN, RH,CA,CT 07M XH 10S RH, RN,CA,CT 10V XN, CA 10M CA, XH 15S RH,RN,CA 15M XH 17V CA, XN 17M CA 25S CA 25V CA 25M CA 208 240 XH, XN XH, XN XH XH XN, XH,CA,CT XN, XH,CA,CT XH XH XN, XH, CA, CT XN, XH, CA, CT CA CA XH XH XN, XH, CA XN, XH, CA XH XH CA CA CA CA CA CA CA CA CA CA 277 480 XH, XN XH, XN, XH, CA CA XH XN, XH, CA CA CA CA, XH XN, XH, CA CA XH CA CA CA CA CA CA CA CA CA CA DT1 XH, XN XN, XH,CA XN, XH, CA CA XH XN, XH, CA XH CA CA CA CA CA DT2 XH, XN XN, XH, CA XN, XH, CA CA XH XN, XH, CA XH CA CA CA CA CA MT1 XH,XN XH XN,XH,CA XH CA,XN,XH CA XH XH,XN,CA XH CA CA CA CA,CT CA MT2 XH,XN XH XN,XH,CA XH CA, XN,XH CA XH XH,XN, CA XH CA CA CA CA,CT CA MT7 XH,XN XH XN,XH,CA XH CA,XN,XH CA XH XH,XN, CA XH CA CA CA CA,CT CA MT8 XH,XN XH XN,XH,CA XH CA,XN,XH CA XH XH,XN,CA XH CA CA CA CA,CT CA TT1 XN,XH XN,XH XN,XH XN,XH CA CA TT7 XN,XH XN,XH XN,XH XN,XH CA CA TT3 347 XN,XH XN,XH,CA,CT XN,XH XN,XH XN,XH XN,XH XN,XH XN,XH,CA CA CA CA CA CA Depot LDP Watts 03S 05S 05M 07S 07M 10S 10V 10M 15S 15M 17V 17M 17V 17M 120 RN RH,RN XH RN, RH XH RH, RN,CA,CT XN, CA CA, XH RH,RN,CA XH CA, XN CA XN,CA,CT CA,CT 208 XH, XN XH XN, XH XH XN, XH, CA, CT CA XH XN, XH, CA XH CA CA CA,CT CA,CT 240 XH, XN XH XN, XH XH XN, XH, CA, CT CA XH XN, XH, CA XH CA CA - 277 XH, XN XH, XN, XH XH XN, XH, CA CA CA, XH XN, XH, CA XH CA CA CA,CT CA,CT 480 CA CA CA,CT CA,CT DT1 XH, XN XN, XH XN, XH, CA CA XH XN, XH, CA XH CA CA - DT2 XH, XN XN, XH XN, XH, CA CA XH XN, XH, CA XH CA CA - MT1 XH,XN XH XN,XH XH CA,XN,XH CA XH XH,XN,CA XH CA CA CA,CT CA,CT See pages 259-264 for a complete listing of Frequently Ordered Products MT2 XH,XN XH XN,XH XH CA,XN,XH CA XH XH,XN, CA XH CA CA CA,CT CA,CT MT7 XH,XN XH XN,XH XH CA, XN,XH CA XH XH,XN, CA XH CA CA CA,CT CA,CT MT8 XH,XN XH XN,XH XH CA,XN,XH CA XH XH,XN,CA XH CA CA CA,CT CA,CT Product Guide 135 Decorative Post Top Lighting B A L L A S T M AT R I C E S American Revolution Series 247 Watts 05S 07S 10S 10V 15S 17V 17M 120 RH, RN RH, CA, CT, RN, MR CA, CT, MR, RH, RN XH, XN, CA, CT RN, RH, CA, CT, MR XN, XH, CA, CT CA 208 XH, XN XH, CA, CT, XN XH, CA, CT, XN CA CA, CT, XN, XH CA CA 220 240 XH, XN - XH, CA, CT, MR, XN - XH, CA, CT, MR, XN CA, CT - CA, CT, XN, XH, MR CA CA, CT, RN, RH CA 277 XH, XN XH, CA, XN CA, XH, XN XN, XH, CA XN, XH, CA CA CA 480 DT1 XH, XN MR XH, XN, CA, CT, MR CA CA, CT, XH, MR, XN CT CT CA, MR XN, XH, CA, CT, MR CA, CT CT CA CA DT2 XH, XN XH, XN, CA, CT, MR CA, CT, MR, XH, XN CT, CA XN, XH, CA, CT, MR CT, CA CA DT3 MR CT MR CT - DT4 MR CT MR CT - MT1 XH, XN XH, XN, CA CA, XN, XH CA XN, XH, CA CA CA MT2 XN,XH XH,XN,CA, CA,XN,XH CA XN,XH,CA CA CA American Revolution Series 247, Continued Watts 05S 07S 10S 10V 15S 17V 17M MT7 XN, XH XH, XN, CA, CA, XN, XH CA XN, XH, CA CA CA MT8 XN, XH XH, XN, CA CA, XN, XH CA XN, XH, CA CA CA TT1 XN, XH XN, XH XN, XH XN, XH - TT7 XN, XH XN, XH XN, XH XN, XH - TT3 XN, XH XN, XH XN, XH XN, XH - 347 XN, XH, CA, CT XN, XH XN, XH XN, XH, CA - Contempo Series 245 Watts 03S 05S 07S 07M 10S 10V 10M 15S 13S 14S 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 120 RN, RH RH, RN RH, CA, CT, RN, MR XH CA, CT, MR, RH, RN XH, XN, CA, CT XH RN, RH, CA, CT, MR RN, RH RN, RH XN, XH, CA, CT CA CA, CT, XN, XH, MR CA, CT, XN, XH, MR XN, XH, CA, CT CA, CT CA, MR XH, XN, CT, CA, MR CT, CA CT, CA 208 XH, XN XH, CA, CT, XN XH XH, CA, CT, XN CA XH CA, CT, XN, XH CA CA CA, CT CA, CT CA CA CA CT, CA, RN, RH CT, CA CT, CA 220 230 RN, RH RN, RH CA RN, RH CA CA RN, RH - 240 277 XH, XN XH, XN XH, CA, CT, MR, XN XH, CA, XN XH XH XH, CA, CT, MR, XN CA, XH, XN CA, CT XN, XH, CA XH XH CA, CT, XN, XH, MR XN, XH, CA CA, CT, RN, RH CA CA CA RN, RH, CA, CT, XN, XH, MR CA, CT RN, RH, CA, CT, MR CA, CT RN, RH, CA, CT CA CA, CT CA CA, MR RN, RH, XN, XH, CA, CT, MR CA CT, CA CA CT, CA CA 480 MR CA CT CA, MR CA, CT CA CA, CT, MR CA, CT, MR CA, CT CA, CT CA, MR CA, MR CA, CT CA, CT DT1 XH, XN XH, XN, CA, CT, MR XH CA, CT, XH, MR, XN CT XH XN, XH, CA, CT, MR CT CA CA, CT, XN, XH, MR XN, XH, CA, CT, MR CA, CT CA, CT CA, MR XN, XH, CA, CT, MR CA, CT CA, CT Contempo Series 245, Continued Watts 03S 05S 07S 07M 10S 10V 10M 15S 13S 14S 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 136 MT1 XH, XN XH, XN, CA XH CA, XN, XH CA XH XN, XH, CA CA CA CA, CT CA, CT CA CA CA CA CA CA MT2 XN, XH XH, XN, CA, XH CA, XN, XH CA XH XN, XH, CA CA CA CA, CT CA, CT CA CA CA CA CA CA Product Guide MT7 XN, XH XH, XN, CA, XH CA, XN, XH CA XH XN, XH, CA CA CA CA, CT CA, CT CA CA CA CA CA CA MT8 XN, XH XH, XN, CA XH CA, XN, XH CA XH XN, XH, CA CA CA CA, CT CA, CT CA CA CA CA CA TT1 XN, XH TT3 XN, XH TT7 XN, XH 347 XN, XH, CA, CT XN, XH XN, XH XN, XH XN, XH XN, XH XN, XH XN, XH XN, XH XN, XH CA CA, CT CA CA - XN, XH CA CA, CT CA CA - XN, XH CA CA, CT CA CA - XN, XH, CA CA CA, CT CA CA CA - For photometric information, please visit our website, www.americanelectriclighting.com DT2 XH, XN XH, XN, CA, CT, MR XH CA, CT, MR, XH, XN CT, CA XH XN, XH, CA, CT, MR CT, CA CA CA, CT, XN, XH, MR XN, XH, CA, CT, MR CA, CT CA, CT CA, MR XN, XH, CA, CT, MR CA, CT CA, CT DT3 MR CT MR CT MR MR CT CT MR MR CT CT DT4 MR CT MR CT MR MR CT CT MR MR CT CT Decorative Post Top Lighting B A L L A S T M AT R I C E S TwistPack Series TWT Wattage 05S 05M 07S 07M 10S 10M 10V 15S 15M 17M 17V 25S 25M 25V 120 RN, RH, XN, XH XN, XH RN, RH, XN, XH, CA, CT XN, XH RN, RH, XN, XH, CA, CT XN, XH, CA XN, XH, CA RN, RH, XN, XH, CA, CT XN, XH, CA CA, CT XN, XH, CA, CT XN, XH, CA, CT CA, CT XN, XH, CA, CT 208 XN, XH XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA XN, XH, CA, CT XN, XH CA, CT CA, CT CA, CT CA, CT CA, CT 240 277 XN, XH XN, XH XN, XH XN, XH XN, XH, CA, CT XN, XH, CA XN, XH XN, XH XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH, CA XN, XH, CA XN, XH, CA XN, XH, CA, CT XN, XH, CA, CT XN, XH RN, RH, XN, XH, CA CA, CT CA CA, CT RN, RH, CA RN, RH, XN, XH, CA, CT CA, CT CA, CT CA RN, RH, CA, CT CA 347 XN, XH XN, XH, CT XN, XH XN, XH, CT XN, XH XN, XH XN, XH, CT XN, XH, CA CA CA CA 600 CT CT CT CT CT CT CT CT DT1 XN, XH XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA XN, XH, CA, CT XN, XH, CT CA, CT CA, CT XN, XH CT CT DT2 TT1 XN, XH XN, XH XN, XH, CA, CT XN, XH XN, XH XN, XH XN, XH, CA, CT XN, XH XN, XH XN, XH XN, XH, CA XN, XH XN, XH, CA, CT XN, XH XN, XH, CT XN, XH, CA CA, CT CA, CT XN, XH CA CT CA, CT CT CA, CT TT7 XN, XH XN, XH XN, XH XN, XH XN, XH XN, XH XN, XH, CA CA CA, CT CA, CT TwistPack Series TWT, Continued Wattage 05S 05M 07S 07M 10S 10M 10V 15S 15M 17M 17V 25S 25M 25V TT3 XN, XH XN, XH XN, XH XN, XH XN, XH XN, XH XN, XH, CA CA CA, CT CA, CT MT1 XN, XH XN, XH XN, XH, CA XN, XH XN, XH, CA, CT XN, XH XN, XH, CA XN, XH, CA, CT XN, XH CA CA CA, CT CA CA MT8 XN, XH XN, XH XN, XH, CA XN, XH XN, XH, CA, CT XN, XH XN, XH, CA XN, XH, CA, CT XN, XH CA CA CA, CT CA CA MT2 XN, XH XN, XH XN, XH, CA XN, XH XN, XH, CA, CT XN, XH XN, XH, CA XN, XH, CA, CT XN, XH CA CA CA, CT CA CA MT7 XN, XH XN, XH XN, XH, CA XN, XH XN, XH, CA, CT XN, XH XN, XH, CA XN, XH, CA, CT XN, XH CA CA CA, CT CA CA Series 870 Watts 05S 07S 10S 10V 15S 17V 17M 120 RN RN, RH, CA, CT RN, RH, CA, CT XN, XH, CT RN, RH, CA, CT XN, XH, CA, CT CA 208 XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT CA CA 240 XN, XH, CA, CT XN, XH, CA, CT CT XN, XH, CA, CT RN, RH, CA, CT CA 277 XN, XH, CA XN, XH, CA, CT XN, XH, CA, CT RN, RH, CA CA 480 CA CA CA CA CA DT1 XN, XH, CA, CT XN, XH, CA, CT CT XN, XH, CA, CT - DT2 XN, XH, CA, CT XN, XH, CA, CT CT XN, XH, CA, CT - MT1 CA, CT CA, CT CA, CT CA CA MT2 MT7 CA, CT CA, CT CA, CT CA, CT CA, CT CA, CT CA CA CA CA MT8 CA, CT CA, CT CA, CT CA CA TT1 XN, XH XN, XH XN, XH CA CA Series 870, Continued Watts 05S 07S 10S 10V 15S 17V 17M TT3 XN, XH XN, XH XN, XH CA CA TT7 XN, XH XN, XH XN, XH CA CA 347 XN, XH, CT XN, XH, CT XN, XH CA CA See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 137 Decorative Post Top Lighting B A L L A S T M AT R I C E S Georgian Series GRP Wattage 05S 05M 07S 07M 10S 10M 10V 15S 15M 17M 17V 120 RN, RH, XN, XH XN, XH RN, RH, XN, XH, CA, CT XN, XH RN, RH, XN, XH, CA, CT XN, XH, CA XN, XH, CA RN, RH, XN, XH, CA, CT XN, XH, CA CA, CT XN, XH, CA, CT 208 XN, XH XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA XN, XH, CA, CT XN, XH CA, CT CA, CT 240 XN, XH XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA XN, XH, CA, CT XN, XH CA, CT RN, RH, CA, CT 277 XN, XH XN, XH XN, XH, CA XN, XH XN, XH, CA, CT XN, XH, CA XN, XH, CA XN, XH, CA, CT RN, RH, XN, XH, CA CARN, RH, CA 347 XN, XH XN, XH, CT XN, XH XN, XH, CT XN, XH XN, XH XN, XH, CT XN, XH, CA CT - 600 CT CT CT CA, CT CT DT1 XN, XH XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA XN, XH, CA, CT XN, XH CA, CT CA, CT Georgian Series GRP, Continued Wattage 05S 05M 07S 07M 10S 10M 10S 15S 15M 17M 17V 138 TT3 XN, XH XN, XH XN, XH XN, XH XN, XH XN, XH XN, XH, CA - MT1 XN, XH XN, XH XN, XH, CA XN, XH XN, XH, CA, CT XN, XH XN, XH, CA XN, XH, CA, CT XN, XH CA CA Product Guide MT8 XN, XH XN, XH XN, XH, CA XN, XH XN, XH, CA, CT XN, XH XN, XH, CA XN, XH, CA, CT XN, XH CA CA MT2 XN, XH XN, XH XN, XH, CA XN, XH XN, XH, CA, CT XN, XH XN, XH, CA XN, XH, CA, CT XN, XH CA CA MT7 XN, XH XN, XH XN, XH, CA XN, XH XN, XH, CA, CT XN, XH XN, XH, CA XN, XH, CA, CT XN, XH CA CA For photometric information, please visit our website, www.americanelectriclighting.com DT2 XN, XH XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA XN, XH, CA, CT XN, XH CA, CT TT1 XN, XH XN, XH XN, XH XN, XH XN, XH XN, XH XN, XH, CA - TT7 XN, XH XN, XH XN, XH XN, XH XN, XH XN, XH XN, XH, CA - SECURITY LIGHTING 315 Series ...............................................................140 NEMA Head 11........................................................142 NEMA Head Package Series 11 PKG .................144 Series 11 “L” Package...........................................146 Series 110 ................................................................148 Dusk To Dawn Series DTD....................................150 Series 165 ................................................................152 Accessories ............................................................154 Ballast Matrices .....................................................155 American Electric Lighting™ 315 Series Security Luminaire Rural Security Lighting Cobrahead with power door and security lighting optics P R O D U C T O V E R V I E W Features: NEW Die-cast secondary Power Pad door places all electrical components on one easily interchangeable module with quick disconnects to main fixture housing. External two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (32mm to 51mm) diameter. Wildlife shield is cast into the housing (not a separate piece) and is easily adjustable for 1-1/4" or 2" (32mm to 51mm) mast arms. Anodized aluminum reflectors provide uniform lighting distribution with acrylic open-bottom refractor. NEMA wattage label, terminal block and NEMA photocontrol receptacle are standard. Includes open-bottom acrylic optics, DTL electronic photo control, lamp, 24” welded arm with 1-1/4” diameter and hardware. This fixture comes with a CWA (Constant Wattage Auto Transformer) ballast, that is designed to keep the lamp operational where line voltage dips are an issue. Applications: Security lighting Rural locations Residential street Remote storage areas E39 mogul socket standard. All electrical components warranted by American Electric Lighting's 6-year guarantee. Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS Complies with ANSI: C136.2, C136.10, C136.15. 27-1/64" (686) 13-5/16" (333.5) 12-15/16" (308) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 315 is 0.9 sq. ft. Approx. Wt. = 19 lbs. 140 Product Guide For photometric information, visit our website, www.americanelectriclighting.com 315 Series Security Luminaire Rural Security Lighting Cobrahead with power door and security lighting optics O R D E R I N G I N F O R M AT I O N Example: 3 1 5 1 5 S C A M T 1 R 5 B A E C P K Ordering Information: Catalog Number 315 07S CA MT1 R5 BA EC PK Description 70W HPS, Multi-tap wired 120V, CWA, Type V, Encapsulated starter 315 10S CA MT1 R5 BA EC PK 100W HPS, Multi-tap wired 120V, CWA, Type V, Encapsulated starter 315 15S CA MT1 R5 BA EC PK 150W HPS, Multi-tap wired 120V, CWA, Type V, Encapsulated starter 315 17V CA MT1 R5 BA PK 175W MV, Multi-tap wired 120V, CWA, Type V 315 17M CA MT1 R5 BA PK 175W MH, Multi-tap wired 120V, CWA, Type V Package includes open-bottom acrylic optics, DTL photocontrol, lamp, 24”welded arm with 1-1/4” diameter and hardware in single carton. See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 141 NEMA Head Series 11 Security Lighting 50-250W HPS, 100-250W MV, 35W LPS P R O D U C T O V E R V I E W Features: Die-cast aluminum head meets NEMA dimension standards. For quick, easy installation of mast arm, a cast-in external slipfitter is used for a secure mounting. Star Friendly™ cutoff distribution pattern available. Available in a variety of IES light distribution patterns , including full cutoff. Tools are not required to install reflector and refractor. Available for arm size 1-1/4" (standard) and 2" fitter. Open-bottom acrylic, polycarbonate, or glass. All electrical components warranted by American Electric Lighting's 6-year guarantee. Suitable for -30°C MH & MV / -40°C HPS. Complies with ANSI: C136.2, C136.6, C136.10 Applications: Security areas Storage yards Loading areas Receiving areas DIMENSIONS 17-3/8" (447) A 16" (406) B Full Cutoff (FC) A B Mercury Vapor 12” 15-1/2” High Pressure Sodium 12” 15-1/2” Low Pressure Sodium 12” 21-3/4” Approx. Wt. = 16 lbs. 142 Product Guide For photometric information, visit our website, www.americanelectriclighting.com NEMA Head Series 11 Security Lighting 50-250W HPS, 100-250W MV, 35W LPS O R D E R I N G I N F O R M AT I O N Example: 1 1 1 0 S R N 1 2 0 R 5 B A Wattage / Source Series 11 NEMA Head 05 07 10 15 17 20 25 50 W 70 W 100 W 150 W 175 W 200 W 250 W Voltage Ballast RN Reactor Normal Power Factor XN High Reactance / Lag Normal Power Factor L LPS S HPS V MV Refer to the ballast matrix on page 155 for compatibility. 120 208 230 240 277 347 MT1 MT8 MT2 MT7 TT1 TT7 TT3 120V 208V 230V 240V 277V 347V 120V Multi-tap 208V Multi-tap 240V Multi-tap 277V Multi-tap Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Distribution R2 R3 R4 R5 RX RO Type II Type III Type IV Type V Type II 4-way1 No optics Optics LO BA BP FC BG Less Optics Open-Bottom Acrylic Open-Bottom Polycarbonate Full Cutoff2 Open-Bottom Glass3 Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative 4 Mast Arm M4 24" arm M3 30" arm Photocontrol Receptacle NR 5 No Photocontrol Receptacle Supply Wire6 SW5 Pre-wire 5' PW5 Wired to terminal block 5' (for more options see page 154) Starter7 (blank) Open board standard EC Encapsulated starter SN No Ignitor (use self-igniting lamp) Fitter Size (blank) 1-1/4“ fitter H2 2” fitter set for 1-1/4“ Lamp LC Lamp Included, Clear LD Lamp Included, Deluxe/Coated LG Self-Igniting Lamp8 Misc. PC NL DPC LA Photocontrol Included per Voltage Specified NEMA Label DTL Control Lightning Arrestor Notes: 1 2 3 4 5 6 7 8 See pages 259-264 for a complete listing of Frequently Ordered Products BA and BG options only Available in R5 distribution only Not available in R4 distribution Available in 1 ¼" aluminum only Not available with PC or DPC option Standard with #14 copper solid, black-white, THHN HPS only Requires SN option Product Guide 143 NEMA Head Package Series 11 PKG Security Light 50-250W HPS, 100-250W MV P R O D U C T O V E R V I E W Features: Die-cast aluminum head meets NEMA dimension standards. For quick easy installation of mast arm, a cast-in external slipfitter is used for a secure mounting. Available in a variety of IES light distribution patterns including full cutoff. Star Friendly™ cutoff distribution patterns available. Tools are not required to install reflector and refractor. Includes 24”, 1-1/4” diameter mast arm with welded brackets, lamp, photocontrol, 5’ of supply wire and hardware. All components in single carton. Open-bottom acrylic, polycarbonate or glass. All electrical components warranted by American Electric Lighting's 6-year guarantee. Suitable for -30°C MH & MV / -40°C HPS. Applications: Complies with ANSI: C136.2, C136.6, C136.10 Security areas Storage yards Loading areas Receiving areas DIMENSIONS 18.8" (478) Full Cutoff (FC) 12" (305) 32.4" (823) 19 3/8" (492) 16" (406) 34 1/2" (876) Note: Package includes welded bracket, 24” mast arm 1-1/4” diameter, lamp, photocontrol, 5’ of supply wire and hardware. Approx. Wt. = 18 lbs. 144 Product Guide For photometric information, visit our website, www.americanelectriclighting.com NEMA Head Package Series 11 PKG Security Light 50-250W HPS, 100-250W MV O R D E R I N G I N F O R M AT I O N Example: 1 1 P K G 1 5 S R N 1 2 0 R 5 B A E C Wattage / Source Series 11PKG NEMA Head Package 05 07 10 15 17 20 25 50 W 70 W 100 W 150 W 175 W 200 W 250 W S HPS V MV Ballast RN Reactor Normal Power Factor XN High Reactance/Lag Normal Power Factor Refer to the ballast matrix on page 155 for compatibility. Voltage 120 208 230 240 277 347 MT1 MT8 MT2 MT7 TT1 TT7 TT3 Optics Distribution 120V 208V 230V 240V 277V 347V 120V Multi-tap 208V Multi-tap 240V Multi-tap 277V Multi-tap Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V R2 R3 R4 R5 RX Type II Type III Type IV Type V Type II 4-way1 BA Open-Bottom Acrylic BP Open-Bottom Polycarbonate FC Full Cutoff2 BG Open-Bottom Glass3 Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Photocontrol (per voltage specified) (blank) Photocontrol standard DPC DTL Control Starter4 (blank) Open board (standard) EC Encapsulated starter SN No Ignitor (use self-igniting lamp) Lamp (blank) LD LG Lamp Included, Clear Lamp Included, Deluxe/Coated Self-Igniting Lamp5 Misc. NL NEMA Label Notes: 1 2 3 4 5 Available in BG or BA optics Available in R5 distribution only Not available in R4 distribution Available in HPS only Requires SN option Note: Package includes welded bracket, 24” mast arm with 1-1/4” diameter, lamp, photocontrol, 5’ of supply wire and hardware. See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 145 Series 11 “L” Package Security Light 50-150W HPS, 175-250W MV P R O D U C T O V E R V I E W Features: Die-cast aluminum head meets NEMA dimension standards For quick easy installation of mast arm, a cast-in external slipfitter is used for a secure mounting Available in a variety of IES light distributions patterns Includes 18” mast arm, lamp, photocontrol, pre-wire, and hardware All components in single carton Open bottom acrylic All electrical components warranted by American Electric Lighting's 6-year guarantee Suitable for -30°C MH & MV / -40°C HPS Complies with ANSI: C136.2, C136.6, C136.10 UL Listed for wet locations Applications: Rural areas Area lighting Small businesses DIMENSIONS 18.8" (478) 12" (305) 28.5" (724) Note: Package includes 18” mast arm, lamp, photocontrol, pre-wire and hardware. Approx. Wt. = 18 lbs. 146 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Series 11 “L” Package Security Light 50-150W HPS, 175-250W MV O R D E R I N G I N F O R M AT I O N Example: 1 1 L 1 7 V X N 1 2 0 R 5 B A Wattage / Source Series 05 07 10 15 17 20 25 11L Security Package 50 W 70 W 100 W 150 W 175 W 200 W 250 W S HPS V MV Refer to the ballast matrix on page 155 for compatibility. Ballast RN Reactor Normal Power Factor XN High Reactance / Lag Normal Power Factor Voltage 120 230 240 277 347 MT1 MT8 MT2 MT7 TT1 TT7 TT3 Distribution 120V R5 Type V 230V 240V 277V 347V 120V Multi-tap 208V Multi-tap 240V Multi-tap 277V Multi-tap Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Optics BA Open -Bottom Acrylic Options Photocontrol (per voltage specified) (blank) Photocontrol (standard) DPC DTL Control Notes: Package includes 18” mast arm, lamp, photocontrol, and hardware. Mast Arm WA Welded Arm (24” mast arm) Listing (blank) CS UL Listed (standard) CSA certified See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 147 Series 110 Security Light 50W - 150W HPS P R O D U C T O V E R V I E W Features: Die-cast aluminum ballast housing for cool operation. Electrical components are easily accessible. Available in a variety of IES light distribution patterns. Tools are not required to install sag or flat lens. All components in single carton. All electrical components warranted by American Electric Lighting's 6-year guarantee. NEMA label standard. 1-1/4” Mast arm only. Suitable for -30°C MH & MV / -40°C HPS. Complies with ANSI: C136.2, C136.10 Shown with the SA lens option E39 Mogul Socket standard. Applications: Rural areas Small businesses Storage lots Security lighting Roadway lighting General area lighting DIMENSIONS 7-27/32" (199 mm) 23-1/16" (585 mm) 12-3/32" (307 mm) Approx. Wt. = 15 lbs. 148 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Series 110 Security Light 50W - 150W HPS O R D E R I N G I N F O R M AT I O N Example: 1 1 0 1 0 S R N 1 2 0 R 1 L C P C Wattage / Source Series 110 Horizontal Security 05 07 10 13 14 15 17 50 W 70 W 100 W 130 W 140 W 150 W 170 W S HPS M MH V MV Refer to the ballast matrix on page 155 for compatibility. Ballast Voltage RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance/Lag Normal Power Factor XH High Reactance/Lag High Power Factor CA CWA 120 120V 208 208V 220 220V 230 230V 240 240V 277 277V 480 480V MT1 120V Multi-tap MT8 208V Multi-tap MT2 240V Multi-tap MT7 277V Multi-tap DT1 Dual-tap 120/240 wired 120V DT2 Dual-tap 120/240 wired 240V Distribution R1 Type I Lens (blank) SA SP FG No Lens Open Bottom Sag Acrylic Sag Polycarbonate Flat Glass Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle1 PB Phosphor Bronze Contacts Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3-Wire Operation (L1, N, L2 Position) Misc. PC Photocontrol Included per Voltage Specified SS Stainless Steel Fasteners (external) SH Shorting Cap PK Package Includes Photocontrol, Lamp, 24” Welded Arm, 1-1/4” Diameter 5’ Supply Wire NN No NEMA Label Notes: See pages 259-264 for a complete listing of Frequently Ordered Products 1 Not available with PC, PB or SH option Product Guide 149 Dusk to Dawn Series DTD Security Light 150-400W HPS, 175-400W MV/MH P R O D U C T O V E R V I E W Features: Ballast is completely enclosed in arm, but is readily accessible. Available in a variety of IES light distribution patterns All components in single carton. Refractor available in open-bottom acrylic, or polycarbonate. All electrical components warranted by American Electric Lighting's 6-year guarantee. Suitable for -30°C MH & MV / -40°C HPS. Complies with ANSI: C136.2, C136.10 Applications: Rural areas Small businesses Storage lots DIMENSIONS 17" (432) 13" (330) 37" (940) Approx. Wt. = 23 lbs. 150 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Dusk to Dawn Series DTD Security Light 150-400W HPS, 175-400W MV/MH O R D E R I N G I N F O R M AT I O N Example: D T D 1 5 S R H 1 2 0 R 3 B A Wattage / Source Series DTD Dusk to Dawn 15 17 20 23 24 25 31 40 Voltage Ballast 150 W S HPS 175 W V MV 200 W M MH 250/400W wired 250W 250/400W wired 400W 250 W 310 W 400 W RN RH CA CT XN Reactor Normal Power Factor Reactor High Power Factor CWA Auto Reg CWI High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor SC SCWA Refer to the ballast matrix on page 156 for compatibility. 120 208 220 230 240 277 347 MT1 MT2 MT8 MT7 TT1 TT7 TT3 DT1 120V 208V 220V 230V 240V 277V 347V Multi-tap wired 120V Multi-tap wired 240V Multi-tap wired 208V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual-tap 120/240 wired 120V DT2 Dual-tap 120/240 wired 240V DT3 Dual-tap 240/480 wired 240V DT4 Dual-tap 240/480 wired 480V Distribution R3 Type III R5 Type V Optics BA Open-Bottom Acrylic BP Open-Bottom Polycarbonate Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Standard Listing (blank) No Listing CS CSA Certified Photocontrol NR No Photocontrol Receptacle1 Lamp LC LD LG Starter3 SN No Ignitor (use self-igniting lamp) Misc. NL PC SH Notes: NEMA Label Photocontrol included per voltage specified Shorting Cap 1 2 3 Not available with PC or SH option Requires SN option HPS only Lamp Included, Clear Lamp Included, Deluxe/Coated Self-Igniting Lamp2 See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 151 Series 165 Security Lighting Luminaires - Ballast-In-Arm 50-400W HPS, 175-400W MH, 100-400 MV P R O D U C T O V E R V I E W Features: NEW One-piece, die-cast aluminum head and arm configuration for long-life stability and performance. Optical assembly utilizes dual latch mounting for quick, easy and secure installation. Electrical components mounted to power door for installation and maintenance convenience. Gray polyester powder coated housing finish is standard. Refractors available in open-bottom acrylic, polycarbonate and glass. NEMA Label standard. Open board starter standard on HPS units. Suitable for -30°C MH & MV / -40°C HPS. Complies with ANSI: C136.2, C136.10, C136.15, C136.6 Applications: Parking lots Roadways Commercial environments Office communities DIMENSIONS 13.5" (343) 12" (305) 37" (940) Approx. Wt. = 35 lbs. 152 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Series 165 Security Lighting Luminaires - Ballast-In-Arm 50-400W HPS, 175-400W MH, 100-400 MV O R D E R I N G I N F O R M AT I O N Example: 1 6 5 1 7 V X H 1 2 0 R 5 B A L C P C Wattage / Source Series 165 Ballast in Arm 05 07 10 15 17 20 23 24 25 31 40 S HPS M MH V MV 50W 70W 100W 150W 175W 200W 250/400W wired 250W 250/400W wired 400W 250W 310W 400W Refer to the ballast matrix on page 156 for compatibility. RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor CA CWA Auto Reg CT CWI SC SCWA MR Mag Reg Distribution Voltage Ballast 120 208 220 230 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 DT2 DT3 DT4 120V 208V 220V 230V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual-tap 120/240 wired 120V Dual-tap 120/240 wired 240V Dual-tap 240/480 wired 240V Dual-tap 240/480 wired 480V R1 R2 R3 R4 R5 RX Area Type I Area Type II Area Type III Area Type IV Area Type V Type II 4-way1 Optics BA Open-Bottom Acrylic BP Open-Bottom Polycarbonate BG Open-Bottom Glass2 Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Terminal Block (blank) Hard Wired (standard) T2 Wired to L1 & L2 Positions3 T3 3-Wire Operation (L1, N, L2 Position)3 TB Terminal Block3 Listing UL CS Fusing4 SF DF UL Listing (standard) CSA Certified Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle5 Starter (blank) EC Open board (standard) Encapsulated starter Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Misc. PC TL SS Notes: 1 2 3 4 5 BA or BG optics only Not available in R4 distribution Voids UL and CSA listing Voids UL and CSA listing, not available with MT, TT and DT voltages PC option not available with NR option Photocontrol Included per Voltage Specified Tool-less Entry Stainless Steel Hardware See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 153 Accessories P S Pre-wired to terminal block Supply wire included in carton WIRE SIZE AND SPECIFICATION W I R E A B C D E F G H I J K L W M N #10 CU Solid B/W #10 CU Solid B/B #10 CU Solid B/B/W #10 CU Stranded B/W #10 CU Stranded B/B #10 CU Stranded B/B/W #12 CU Solid B/W #12 CU Solid B/B #12 CU Solid B/B/WD #12 CU Stranded B/W #12 CU Stranded B/B #12 CU Stranded B/B/W #14 CU Solid B/W #14 CU Solid B/B #14 CU Solid B/B/W LENGTH P R E - S U P P LY 4 5 6 8 0 4’ 5’ 6’ 8’ 10’ Examples SW5 = 5’ of #14 CU. Solid, B/W wire supplied in carton PW5 = 5’ of #14 CU. Solid, B/W pre-wired to terminal block PD0 = 10’ of #10 CU. Stranded, B/W pre-wired to terminal block 154 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Security Lighting B A L L A S T M AT R I C E S Nema Head 11 Watts 05S 07S 10S 10V 15S 17V 20S 25S 25V 120 RN RN RN XN RN XN XN XN XN 208 XN XN XN XN - 230 RN RN RN - 240 XN XN XN XN RN RN RN RN 277 XN XN XN XN XN RN - MT1 XN XN XN XN - MT2 XN XN XN XN - MT7 XN XN XN XN - MT8 XN XN XN XN - TT1 XN XN XN XN - TT7 XN XN XN XN - TT3 XN XN XN XN - 347 XN XN XN XN - Nema Head Package Series 11PKG Watts 05S 07S 10S 10V 15S 17V 20S 25S 25V 120 RN RN RN XN RN XN XN XN XN 208 XN XN XN XN - 230 RN RN RN - 240 XN XN XN XN RN RN RN RN 277 XN XN XN XN XN RN - 240 XN XN XN XN RN RN RN RN 277 XN XN XN XN XN RN - MT1 XN XN XN XN - MT2 XN XN XN XN - MT7 XN XN XN XN - MT8 XN XN XN XN - TT1 XN XN XN XN - TT7 XN XN XN XN - TT3 XN XN XN XN - 347 XN XN XN XN - Series 11L Package Watts 05S 07S 10S 10V 15S 17V 20S 25S 25V 120 RN RN RN XN RN XN XN XN XN 208 XN XN XN XN - 230 RN RN RN - MT1 XN XN XN XN - MT2 XN XN XN XN - MT7 XN XN XN XN - MT8 XN XN XN XN - TT1 XN XN XN XN - TT7 XN XN XN XN - TT3 XN XN XN XN - 347 XN XN XN XN - Series 110 Watts 05S 07S 10S 15S 17V 17M 13S 14S 120 RH, RN RH, RN, CA RH, RN, CA RH, RN CA, XN, XH CA RN, RH RN, RH 208 X CA, XH, XN CA, XH, XN XN, XH CA CA - 220 RN, RH, XN, XH RN, RH - 230 RN, RH RN, RH CA - 240 CA, XN, XH CA, XN, XH XN, XH, RN, RH RH, RN, CA CA - 277 CA, XH, XN CA, XH, XN XN, XH RN, RH, CA CA - 480 CA CA - DT1 XN, XH CA, XN, XH CA, XN, XH XN, XH CA CA - DT2 XN, XH CA, XN, XH CA, XN, XH XN, XH CA CA - MT1 XN, XH CA, XN, XH CA, XN, XH XN, XH CA CA - MT2 XN, XH CA, XN, XH CA, XN, XH XN, XH CA CA - Series 110 continued Watts 05S 07S 10S 15S 17V 17M 13S 14S MT7 XN, XH CA, XN, XH CA, XN, XH XN, XH CA CA - MT8 XN, XH CA, XN, XH CA, XN, XH XN, XH CA CA - See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 155 Security Lighting B A L L A S T M AT R I C E S Dusk To Dawn Watts 15S 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 23/24M 120 RN, RH, CA, CT, MR XN, XH, CA, CT CA CA, CT, XN, XH, MR XH, XN, CA, CT, MR CT, CA, XN, XH CA, CT, SC CA, MR CA, CT, XN, XH CA, CT, XN, XH CA, CT, SC CA, CT CA 208 CA, CT, XN, XH CA CA CA, CT CA,CT CA CA, CT, SC CA CA, CT CA, CT CA, CT, SC CA, CT CA 220 CA RN, RH CA CA RN, RH CA CA - 230 RN, RH RN, RH RN, RH RN, RH - 240 277 CA, CT, XN, XH, MR XN, XH, CA CA, CT, RN, RH CA, RN CA CA CA, CT, RN, RH, MR CA, CT, MR RN, RH, CA, CT, MR CA, CT RH, RN, CA, CT CA CA, CT, SC CA, SC CA, MR CA RH, RN, CA, CT CA, CT CA, CT, XN, XH CA, CT CA, CT, SC CA, SC CA, CT CA, CT CA CA 480 CA, MR CA, CT CA CA, CT, MR CA, MR CA, CT CA, CT CA, MR CA CT, CA CA, CT, CA CA DT1 XN, XH, CA, CT, MR CT, CA CA XN, XH, CA, CT, MR XN, XH, MR CA, CT CA, CT, SC CA, MR CA, CT, XN, XH CA, CT, XN, XH CA, CT CA, CT CA DT2 XN, XH, CA, CT, MR CT, CA CA XN, XH, CA, CT, MR XN, XH, MR CA, CT CA, CT, SC CA, MR CA, CT, XN, XH CA, CT, XN, XH CA, CT CA, CT CA Dusk To Dawn continued Watts 15S 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 23/24M DT3 MR CT MR MR CT CT MR CT CT - DT4 MR CT MR MR CT CT MR CT CT - MT1 XN,XH,CA,CT CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA MT2 XN,XH,CA,CT CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA MT7 XN,XH,CA,CT CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA MT8 XN,XH,CA,CT CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA TT1 XN,XH CA CA CA CA CA CA - TT7 XN,XH CA CA CA CA CA CA - TT3 XN,XH CA CA CA CA CA CA - 347 XN,XH,CA CA CA CA CA CA CA CA - Series 165 Watts 05S 07S 10S 10V 15S 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 23/24M 120 RH, RN RH, CA, CT, RN, MR CA, CT, MR, RH, RN XH, XN, CA, CT RN, RH, CA, CT, MR XN, XH, CA, CT CA CA, CT, XN, XH MR XH, XN, CA, CT CT, CA, XN, XH CA, CT, SC CA, MR CA, CT, XN, XH CA, CT, XN, XH CA, CT, SC CA, CT CA 208 XH, XN XH, CA,CT, XN XH, CA, CT, XN CA CA, CT, XN, XH CA CA CA, CT CA, CT CA CA, CT, SC CA CA, CT CA, CT CA, CT, SC CA, CT CA 220 CA RN, RH CA CA RN, RH CA CA - 230 RN, RH RN, RH RN, RH RN, RH RN, RH - 240 XH, XN XH, CA, CT, MR, XN XH, CA, CT, MR, XN CA, CT CA, CT, XN, XH, MR CA, CT, RN, RH CA CA, CT, RN, RH, MR RN, RH, CA, CT RH, RN, CA,CT CA, CT, SC CA, MR RH, RN, CA, CT CA, CT, XN, XH CA, CT, SC CA, CT CA 277 XH, XN XH, CA, XN CA, XH, XN XN, XH, CA XN, XH, CA CA, RN CA CA, CT, MR CA, CT CA CA, SC CA CA, CT CA, CT CA, SC CA, CT CA 480 MR CA CT CA, MR CA, CT CA CA, CT, MR CA CA, CT CA, CT CA, MR CA CT, CA CA, CT CA CA DT1 XH, XN XH, XN, CA, CT, MR CA, CT, XH, MR, XN CT XN, XH, CA, CT, MR CT, CA CA XN, XH, CA, CT, MR XN, XH CA, CT CA, CT, SC CA, MR CA, CT, XN, XH CA, CT, XN, XH CA, CT CA, CT CA Series 165 continued Watts 05S 07S 10S 10V 15S 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 23/24M 156 DT3 MR CT MR CT MR CT CT MR CT CT - DT4 MR CT MR CT MR CT CT MR CT CT - Product Guide MT1 XH,XN XH,XN,CA CA,XN,XH CA XN,XH,CA,CT CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA MT2 XN,XH XH,XN,CA, CA,XN,XH CA XN,XH,CA,CT CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA MT7 XN,XH XH,XN,CA, CA,XN,XH CA XN,XH,CA,CT CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA MT8 XN,XH XH,XN,CA CA,XN,XH CA XN,XH,CA,CT CA CA CT,CA CA,CT CA CA,SC CA CA,CT CA CA,SC CA,CT CA TT1 XN,XH XN,XH XN,XH XN,XH CA CA CA CA CA CA - TT7 XN,XH XN,XH XN,XH XN,XH CA CA CA CA CA CA - For photometric information, visit our website, www.americanelectriclighting.com TT3 XN,XH XN,XH XN,XH XN,XH CA CA CA CA CA CA - 347 XN,XH,CA,CT XN,XH XN,XH XN,XH,CA CA CA CA CA CA CA CA - DT2 XH, XN XH, XN, CA, CT, MR CA, CT, MR, XH, XN CT, CA XN, XH, CA, CT, MR CT, CA CA XN, XH, CA, CT, MR XN, XH CA, CT CA, CT, SC CA, MR CA, CT, XN, XH CA, CT, XN, XH CA, CT CA, CT CA AREA LIGHTING AVL ..........................................................................158 LuxMaster® Luminaire Series 53 ......................160 LuxMaster® Luminaire Series 153 ....................162 LuxMaster® Classic Series LS............................164 LuxMaster® Classic Series LM ..........................166 LuxMaster® Classic Series LL ............................168 LuxMaster® LPS Luminaire Series LML............170 Accessories ..........................................................172 Ballast Matrices....................................................176 American Electric Lighting™ AVL Area Lighting 250-1000W HPS, 250-1000W MH P R O D U C T O V E R V I E W Features: Rugged, heavy-gauge aluminum housing is continuously seam welded for weathertight integrity. Silicone gasket seals optical compartment from moisture, insects and dust. Available in multiple mounting options to fit a variety of applications. Choice of drop or flat lens to allow for full cutoff compliance. Available in a variety of IES light distributions patterns. Star Friendly™ cutoff distribution patterns available. 1000W MH designed around reduced jacket lamp. Tool-less die-cast latching available. Choice of bolt spacing for mounting arm (4-1/4” or 4-7/8”). Mogul base, E39 socket standard. All electrical components warranted by American Electric Lighting's 6-year guarantee. Applications: Suitable for -30°C MH & MV / -40°C HPS. Parking lots Roadways Commercial environments Office communities DIMENSIONS AVL Drop Glass AVL Flat Glass 17.5" (445) 14" (356) 21.6" (549) 21.6" (549) Effective Projected Area (EPA) The EPA for the AVL is 2.8 sq. ft. Approx. Wt = 53 lbs. 158 Product Guide 21.6" (549) 21.6" (549) For photometric information please visit our website: www.americanelectriclighting.com AVL Area Lighting 250-1000W HPS, 250-1000W MH O R D E R I N G I N F O R M AT I O N Example: A V L 1 X M C A M T 7 S M D G S 9 Wattage / Source Series AVL American Vertical Luminaire 25 31 32 35 40 45 75 1X 250W 310W 320W1 350W1 400W 450W1 750W 1000W1 S HPS M MH CA CWA SC SCWA2 CT CWI Refer to the ballast matrix on page 176 for compatibility. Distribution Voltage Ballast 120 208 220 230 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 DT2 DT3 DT4 Optics Vertical Lamp 120V AM Asymmetric 208V SM Symmetric 220V FV Forward Throw 230V 240V Horizontal Lamp 277V R2 Area Type II 347V R3 Area Type III 480V FT Forward Throw Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual-tap 120/240 wired 120V Dual-tap 120/240 wired 240V Dual-tap 240/480 wired 240V Dual-tap 240/480 wired 480V FG Flat Glass Clear Tempered DG Drop Glass Clear Tempered Refer to Optical Matrix below. Mounting3 S9 P9 S2 P2 WP WB EF Square Pole 9” Arm Round Pole 9” Arm Square Pole 12” Arm Round Pole 12” Arm Wood Pole or Wall 12” Arm Wall Bracket 12” Arm External Mast Arm Fitter Options Maximum number of options is five, for more options please contact your local American Electric Lighting representative Paint4 (blank) BK GY WH UP Bronze (standard) Black Gray White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3-Wire Operation (L1, N, L2 Position) Listing UL CS UL Listing CSA Certified Fusing5 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle6 Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Starter7 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Plug-in Misc. A4 PC TL SS 5H NL SH TR Notes: 1 2 3 4-7/8” Hole Spacing on Housing and Arm Photocontrol Included per Voltage Specified Tool-less Entry Stainless Steel Fasteners (external) 50 Hertz Ballast Cycle8 NEMA Label on Housing Shorting Cap Trigger Latch 4 5 6 7 8 Reduced jacket lamp only Pulse Start Metal Halide only Standard arm-hole bolt spacing is 4-1/4” For 4-7/8” spacing, order “A4” option. Other colors available; please contact your local American Electric Lighting representative Voids UL/CSA Listing, not available with MT, TT and DT voltages PC and SH not available with NR option HPS only, 400W max Limited availability; please contact your local American Electric Lighting representative Accessories (shipped separately) AVLEHS U Field installable external HS shield universal tenon adapter AVL Optical Matrix 25S 31S 40S X1S 25M 32M 35M 40M 75M X1M AM FG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ SM FG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ See pages 259-264 for a complete listing of Frequently Ordered Products AM DG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ SM DG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ FV DG ◆ R2 FG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ R3 FG ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ - Product Guide 159 LuxMaster® Series 53 Area Lighting 70-150W HPS, 100-175W MV, 175W MH P R O D U C T O V E R V I E W Features: Durable die-cast aluminum housing for long-life performance. Optical assembly designed for maximum performance. Removable ballast tray electrical system for installation and maintenance ease. "Breathing Seal" developed by American Electric prevents contaminants from entering optical assembly for maximum efficiency. Optics available in flat tempered glass, sag glass, drop acrylic and drop polycarbonate. Available in a variety of IES light distributions patterns and cutoff classifications. Star Friendly™ cutoff distribution patterns available. Applications: Standard product is designed to mount to pipe mast arm. Direct pole mount arms are available. Parking lots Roadways Residential communities Commercial environments Office communities All electrical components warranted by American Electric Lighting's 6-year guarantee. Arm ordered separate, see page 175. UL Listed. Mogul base, E39, socket standard. Suitable for -30°C MH & MV / -40°C HPS. Complies with ANSI: C136.2, C136.10, C136.14, C136.15 DIMENSIONS 13.4" (340) 23" (584) 8.25" (210) 23" (584) 13.4" (326) 5.25" (128) Effective Projected Area (EPA) The EPA for the LuxMaster® Series 53 with refractor 1.4 sq. ft. Approx. Wt = 30 lbs. 160 Product Guide Effective Projected Area (EPA) The EPA for the LuxMaster® Series 53 with flat lens is 1.1 sq. ft. For photometric information please visit our website: www.americanelectriclighting.com LuxMaster® Series 53 Area Lighting 70-150W HPS, 100-175W MV, 175W MH O R D E R I N G I N F O R M AT I O N Example: 5 3 1 5 S C A M T 1 R 3 F G L C P C 53 LuxMaster Shoebox 07 10 15 17 S HPS M MH V MV 70W 100W 150W 175W Voltage Ballast Wattage / Source Series Refer to the ballast matrix on page 176 for compatibility. RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor CA CWA Auto Reg MR Mag Reg (3 coil) CT CWI 120 208 220 230 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 DT2 DT3 DT4 Distribution R2 Roadway Type II 120V R3 Roadway Type III 208V 220V Refer to Optical Matrix 230V below. 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Optics Multi-tap wired 277V Tri-tap wired 120V DA Drop Acrylic Tri-tap wired 277V Prismatic Refractor Tri-tap wired 347V DP Drop Polycarbonate Dual-tap 120/240 wired 120V Prismatic Refractor Dual-tap 120/240 wired 240V FG Flat Glass Clear Dual-tap 240/480 wired 240V Tempered Dual-tap 240/480 wired 480V SG Sag Glass Refractor Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Mounting (blank) Internal fitter (1-1/4”) M2 Internal fitter (pre-set 2”) Paint1 (blank) BK GY WH Bronze (standard) Black Gray White Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3-Wire Operation (L1, N, L2 Position) Fusing2 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle3 PB Phosphor Bronze Contacts Lamp LC LD LG Lamp Included, Clear Lamp Included, Deluxe Self-Igniting Lamp4 Starter5 (blank) EC OP PS SN Listing (blank) CS Misc. PC SS LA 5H NL SH HK Notes: Open Board (standard) Encapsulated Plug-in Open Plug-in Protected/Auto Shutoff6 No Ignitor (using self-igniting lamp) 1 2 3 4 5 6 UL Listed (standard) CSA Certified Other colors available; please contact your local American Electric Lighting representative Voids UL/CSA Certified Options and not available in MT, TT and DT voltages PB, PC and SH not available with NR option Requires SN option HPS only Limited availability; please contact your local American Electric Lighting representative Photocontrol Included per Voltage Specified Stainless Steel Fasteners (external) Lightning Arrestor (Void UL/CSA Listed Options) 50 Hertz Ballast Cycle6 NEMA Label on Housing Shorting Cap Hinge Keeper Series 53 Optical Matrix 05S 07S 10S 15S 17M 17V R2 DA ◆ ◆ ◆ ◆ - R3 DA ◆ ◆ ◆ ◆ - See pages 259-264 for a complete listing of Frequently Ordered Products R2 DP ◆ ◆ ◆ ◆ - R3 DP ◆ ◆ ◆ ◆ - R2 FG ◆ ◆ ◆ ◆ ◆ ◆ R3 FG ◆ ◆ ◆ ◆ ◆ ◆ R2 SG ◆ ◆ ◆ ◆ ◆ ◆ R3 SG ◆ ◆ ◆ ◆ ◆ ◆ Product Guide 161 LuxMaster® Luminaire Series 153 Area Lighting 200-400W HPS, 200-400W MV/MH P R O D U C T O V E R V I E W Features: Die-cast aluminum housing for long-life performance. Optical assembly designed for maximum performance. Ballast tray electrical system for installation and maintenance ease. "Breathing Seal" developed by American Electric preventing contaminants from entering optical assembly. Optics available in flat tempered glass, sag glass, drop acrylic and drop polycarbonate. Available in a variety of IES light distributions patterns. Star Friendly™ cutoff distribution patterns available. Standard product is designed to mount to pipe mast arm. Direct pole mount arms are available. Arm ordered separate, see page 175. Applications: UL Listed. Parking lots Roadways Residential communities Commercial environments Office communities All electrical components warranted by American Electric Lighting's 6-year guarantee. Mogul base, 539 socket std. Suitable for -30°C MH & MV / -40°C HPS. Complies with ANSI: C136.2, C136.10, C136.14, C136.15 DIMENSIONS 17" (450) 27.1" (689) 8.25" (201) 27.12" (662) 17" (432) 8.2" (209) Effective Projected Area (EPA) The EPA for the LuxMaster® HPS Luminaire Series 153 with flat lens is 2.1 sq. ft. Approx. Wt = 45 lbs. 162 Product Guide The EPA for the LuxMaster® HPS Luminaire Series 153 with drop lens is 2.4 sq. ft. For photometric information please visit our website: www.americanelectriclighting.com LuxMaster® Luminaire Series 153 Area Lighting 200-400W HPS, 200-400W MV/MH O R D E R I N G I N F O R M AT I O N Example: 1 5 3 2 5 S C A M T 1 R 3 F G L C E C P C Wattage / Source Series 153 LuxMaster Shoebox S HPS M MH V MV 20 25 31 40 23 200W 250W 310W 400W 250/400W wired 250 24 250/400W wired 400 Refer to the ballast matrix on page 179 for compatibility. Distribution Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor CA CWA Auto Reg MR Mag Reg (3 coil) CT CWI 120 208 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 DT2 DT3 DT4 R2 Roadway Type II 120V R3 Roadway Type III 208V 240V Refer to Optical Matrix 277V below. 347V 480V Multi-tap wired 120V Multi-tap wired 208V Optics Multi-tap wired 240V Multi-tap wired 277V DA Drop Acrylic Tri-tap wired 120V Prismatic Refractor Tri-tap wired 277V DP Drop Polycarbonate Tri-tap wired 347V Prismatic Refractor Dual-tap 120/240 wired 120V FG Flat Glass Clear Dual-tap 120/240 wired 240V Tempered Dual-tap 240/480 wired 240V SG Sag Glass Dual-tap 240/480 wired 480V Prismatic Refractor Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Mounting (blank) Internal fitter (1-1/4”) M2 Internal fitter (pre-set 2”) Paint1 (blank) BK GY WH Bronze (standard) Black Gray White Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Fusing2 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle3 PB Phosphor Bronze Contacts Lamp LC LD LG Lamp Included, Clear Lamp Included, Deluxe Self Igniting Lamp4 Starter5 (blank) EC OP PS SN Listing (blank) CS Misc. PC SS LA 5H NL SH HK Notes: Open Board (standard) Encapsulated Plug-in Open Plug-in Protected/Auto Shutoff6 No Ignitor (using self-igniting lamp) 1 2 3 4 5 6 UL Listed (standard) CSA Certified Other colors available; please contact your local American Electric Lighting representative Voids UL/CSA listing, not available with MT, TT and DT voltages PB, PC, and SH not available with NR option Requires SN option HPS only Limited availability; please contact your local American Electric Lighting representative Photocontrol Included per Voltage Specified Stainless Steel Fasteners (external) Lightning Arrestor 50 Hertz Ballast Cycle6 NEMA Label on Housing Shorting Cap Hinge Keeper Series 153 Optical Matrix 20S 31S 40S 25M 40M R2 DA ◆ ◆ ◆ - R3 DA ◆ ◆ ◆ - R2 DP ◆ ◆ ◆ - R3 DP ◆ ◆ ◆ - R2 FG ◆ ◆* R3 FG ◆ ◆ ◆ - R2 SG ◆ ◆ ◆ - R3 SG ◆ ◆ ◆ ◆ ◆ * Requires use of ED28 lamp See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 163 LuxMaster® Classic Series LS Area Lighting 70-150W HPS, 175W MH/MV P R O D U C T O V E R V I E W Features: Rugged heavy gauge aluminum housing is continuously seam welded for weathertight integrity. Multiple mounting options to fit a variety of applications. Optical assembly designed for maximum performance. Removable ballast tray electrical system for installation and maintenance ease. Mogul base, E39 socket standard. "Breathing Seal" developed by American Electric prevents contaminants from entering optical assembly for maximum efficiency. Tempered flat glass lens standard, drop polycarbonate option available. Available in a variety of IES full cutoff light distributions patterns. Star Friendly™ cutoff distribution patterns available. All electrical components warranted by American Electric Lighting's 6-year guarantee. Applications: Suitable for -30°C MH & MV / -40°C HPS. Parking lots Office complexes Security lighting Residential areas Commercial environments DIMENSIONS 9" (229) 15" (381) 15" (381) Effective Projected Area (EPA) The EPA for the LuxMaster Classic Luminaire, Series LS is 1.75 sq. ft. Approx. Wt. = 20 lbs. 164 Product Guide For photometric information please visit our website: www.americanelectriclighting.com LuxMaster® Classic Series LS The following three separate components must be ordered: 1) BALLAST TRAY 2) HOUSING 3) MOUNTING Area Lighting 70-150W HPS, 175W MH/MV O R D E R I N G 1) Ballast Tray Example: L S 1 5 S R H 1 2 0 R 3 Wattage / Source Series LS LuxMaster Shoebox 07 10 15 17 70W 100W 150W 175W S HPS M MH V MV Distribution Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor CA CWA Auto Reg CT CWI MR Mag Reg Refer to the ballast matrix on page 177 for compatibility. 120 208 220 230 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 DT2 DT3 DT4 120V 208V 220V 230V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual-tap 120/240 wired 120V Dual-tap 120/240 wired 240V Dual-tap 240/480 wired 240V Dual-tap 240/480 wired 480V O R D E R I N G 2) Housing Series LS LuxMaster Shoebox R2 Roadway Type II R3 Roadway Type III R5 Roadway Type V Options Fusing1 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle2 PB Phosphor Bronze Contacts I N F O R M AT I O N Example: L S 1 5 S R 3 H S G P C Wattage / Source 07 10 15 17 XX Options Housing S HPS 70W M MH 100W V MV 150W 175W No Ballast3 HSG Housing Unit Distribution R2 Roadway Type II R3 Roadway Type III R5 Roadway Type V O R D E R I N G 3) Mounting Paint4 (blank) BK GY WH Misc. SS Bronze (standard) Black Gray White SH DP PC Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle2 PB Phosphor Bronze Contacts Example: L M P B Z Series Notes: Paint Mounting P W K M T 1 2 3 Square Pole 12” Arm Wall Bracket 12” Arm Adjustable Knuckle External Fitter Square Tenon Square Tenon 2 arms 90° Square Tenon 2 arms 180° Square Tenon 3 arms 90° 4 5 6 7 8 9 R LC WY Stainless Steel Fasteners (external) Shorting Cap Drop Polycarbonate5 Photocontrol included per voltage specified Lamp Included, Clear Wraparound Yoke I N F O R M AT I O N 1 LM LuxMaster Shoebox I N F O R M AT I O N Square Tenon 4 arms 90° Round Tenon Round Tenon 2 arms 90° Round Tenon 2 arms 180° Round Tenon 3 arms 90° Round Tenon 3 arms 120° Round Tenon 4 arms 90° 2 Paint4 BZ Bronze (standard) BK Black GY Gray WH White See pages 259-264 for a complete listing of Frequently Ordered Products 3 4 5 Voids UL/CSA Certified Options and not available in MT, TT,and DT voltages PB, PC and SH not available with NR option NL not available Other colors available; please contact your local American Electric Lighting representative Available in R3 and R5 distributions Product Guide 165 LuxMaster® Classic Series LM Area Lighting 200-400M HPS, 250-400W MH/MV P R O D U C T O V E R V I E W Features: Rugged heavy gauge aluminum housing is continuously seam welded for weathertight integrity. Multiple mounting options to fit a variety of applications. Optical assembly designed for maximum performance. Removable ballast tray electrical system for installation and maintenance ease. Mogul base, E39 socket standard. "Breathing Seal" developed by American Electric prevents contaminants from entering optical assembly for maximum efficiency. Star Friendly™ cutoff distribution patterns available. Tempered flat glass lens standard, drop polycarbonate option available. Available in a variety of IES full cutoff light distributions patterns. All electrical components warranted by American Electric Lighting's 6-year guarantee. Applications: Office complexes Parking lots Residential areas Commercial environments Security lighting Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS 10" (254) 19" (483) 19" (483) Effective Projected Area (EPA) The EPA for the LuxMaster Classic Luminaire, Series LM is 2.36 sq. ft. Approx. Wt. = 45 lbs. 166 Product Guide For photometric information please visit our website: www.americanelectriclighting.com LuxMaster® Classic Series LM The following three separate components must be ordered: 1) BALLAST TRAY 2) HOUSING 3) MOUNTING Area Lighting 200-400M HPS, 250-400W MH/MV O R D E R I N G 1) Ballast Tray Example: L M 2 0 S X H 1 2 0 R 3 Wattage / Source Series LM LuxMaster Shoebox I N F O R M AT I O N S HPS M MH V MV 20 200W 25 250W 40 400W RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor CA CWA Auto Reg CT CWI MR Mag Reg Refer to the ballast matrix on page 178 for compatibility. Distribution Voltage Ballast 120 208 220 230 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 DT1 DT2 DT3 DT4 120V 208V 220V 230V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual-tap 120/240 wired 120V Dual-tap 120/240 wired 240V Dual-tap 240/480 wired 240V Dual-tap 240/480 wired 480V O R D E R I N G LM LuxMaster Shoebox Wattage / Source Single Fuse (120, 277, 347V) DF Double Fuse (208, 220, 240, 480V) Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3-Wire Operation (L1, N, L2 Position) Photocontrol Receptacle NR No Photocontrol Receptacle2 I N F O R M AT I O N 20 25 31 40 200W 250W 310W 400W Options Housing S HPS M MH V MV HSG Housing Unit Distribution R2 Roadway Type II R3 Roadway Type III R5 Roadway Type V O R D E R I N G 3) Mounting Paint3 (blank) BK GY WH Misc. PC Bronze (standard) Black Gray White SS Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) PB Phosphor Bronze Contacts NR No Photocontrol Receptacle2 Example: L M P B Z Series Mounting P W K M T 1 2 3 Square Pole 12” Arm Wall Bracket 12” Arm Adjustable Knuckle External Fitter Square Tenon Square Tenon 2 arms 90° Square Tenon 2 arms 180° Square Tenon 3 arms 90° 4 5 6 7 8 9 R SH DP WY Photocontrol Included per Voltage Specified Stainless Steel Fasteners (external) Shorting Cap Drop Polycarbonate4 Wraparound Yoke I N F O R M AT I O N Notes: 1 LM LuxMaster Shoebox Options Fusing1 SF Example: L M 2 0 S R 3 H S G 2) Housing Series R2 Roadway Type II R3 Roadway Type III R5 Roadway Type V Square Tenon 4 arms 90° Round Tenon Round Tenon 2 arms 90° Round Tenon 2 arms 180° Round Tenon 3 arms 90° Round Tenon 3 arms 120° Round Tenon 4 arms 90° Paint 2 Paint3 BZ Bronze (standard) BK Black GY Gray WH White 3 See pages 259-264 for a complete listing of Frequently Ordered Products 4 Voids UL/CSA Certified options and not available in MT, TT, and DT voltages PC and SH not available with NR option Other colors available; please contact your local American Electric Lighting representative Available in R3 and R5 distributions Product Guide 167 LuxMaster® Classic Series LL Area Lighting 1000W HPS/MH P R O D U C T O V E R V I E W Features: Rugged heavy gauge aluminum housing is continuously seam welded for weathertight integrity. Multiple mounting options to fit a variety of applications. Optical assembly designed for maximum performance. Removable ballast tray electrical system for installation and maintenance ease. "Breathing Seal" developed by American Electric prevents contaminants from entering optical assembly for maximum efficiency. Star Friendly™ cutoff distribution patterns available. Mogul base, E39 socket standard. Tempered flat glass lens. Available in Type II and III full cut off classifications. Applications: All electrical components warranted by American Electric Lighting's 6-year guarantee. Parking lots Residential communities Commercial environments Security lighting Office complexes Suitable for -30°C MH & MV / -40°C HPS. DIMENSIONS 25" (634) 25" (634) 12" (305) Effective Projected Area (EPA) The EPA for the LuxMaster Classic Luminaire, Series LL is 3.5 sq. ft. Approx. Wt. = 57 lbs. 168 Product Guide For photometric information please visit our website: www.americanelectriclighting.com LuxMaster® Classic Series LL The following three separate components must be ordered: 1) BALLAST TRAY 2) HOUSING 3) MOUNTING Area Lighting 1000W HPS/MH O R D E R I N G 1) Ballast Tray Example: L L X 1 M C A M T 1 R 3 Wattage / Source Series X1 1000W LL LuxMaster Shoebox I N F O R M AT I O N S HPS M MH CA CWA Auto Reg CT CWI RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor Refer to the ballast matrix on page 178 for compatibility. Distribution Voltage Ballast 120 208 220 230 240 277 347 480 MT1 MT2 MT7 DT1 DT2 120V 208V 220V 230V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 240V Multi-tap wired 277V Dual-tap 120/240 wired 120V Dual-tap 120/240 wired 240V O R D E R I N G 2) Housing Options Fusing1 SF Single Fuse (120, 277, 347V) DF Double Fuse (208, 220, 240, 480V) Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3-Wire Operation (L1, N, L2 Position) Photocontrol Receptacle NR No Photocontrol Receptacle2 PB Phosphor Bronze Contacts I N F O R M AT I O N Example: L L X 1 M R 3 H S G P C Wattage / Source Series LL LuxMaster Shoebox R2 Roadway Type II R3 Roadway Type III X1 1000W Options Housing S HPS M MH HSG Housing Unit Distribution R2 Roadway Type II R3 Roadway Type III O R D E R I N G 3) Mounting Paint3 (blank) BK GY WH Misc. PC Bronze (standard) Black Gray White SS Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle2 PB Phosphor Bronze Contacts SH WY Photocontrol Included per Voltage Specified Stainless Steel Fasteners (external) Shorting Cap Wraparound Yoke I N F O R M AT I O N Example: L M P B Z Notes: Series LM LuxMaster Shoebox Mounting P T 1 2 3 4 Square Pole 12” Arm Square Tenon Square Tenon 2 arms 90° Square Tenon 2 arms 180° Square Tenon 3 arms 90° Square Tenon 4 arms 90° 5 6 7 8 9 R Round Tenon Round Tenon 2 arms 90° Round Tenon 2 arms 180° Round Tenon 3 arms 90° Round Tenon 3 arms 120° Round Tenon 4 arms 90° Paint 1 Paint3 BZ Bronze (standard) BK Black GY Gray WH White 2 See pages 259-264 for a complete listing of Frequently Ordered Products 3 Voids UL/CSA Certified options and not available in MT, TT, and DT voltages PB, PC and SH not available with NR option Other colors available; please contact your local American Electric Lighting representative Product Guide 169 LuxMaster® LPS Series LML LPS Area Lighting 55-180W LPS P R O D U C T O V E R V I E W Features: Energy-efficient LPS light source. Suitable for marine environments. Three durable formed housings available to accentuate a variety of themes. Hinged captive bezel secured by captive screws for ease of maintenance. Star Friendly™ cutoff distribution patterns available. Mounts to standard 1-1/2" or 2" OD mast arm. Full perimeter silicone sponge gasket. All electrical components warranted by American Electric Lighting's 6-year guarantee. Suitable for -30°C MH & MV / -40°C HPS. Applications: Roadways Parking lots Perimeter lighting Transportation terminals Shopping centers Industrial sites Designated for intrinsically dark areas, such as those surrounding observatories and sea turtle habitats DIMENSIONS TOP B C SIDE A END A B LAMP WATTS A B C EPA 55-90 8'' 143/8'' 30'' 2.83 135 8'' 143/8'' 40'' 3.78 180 8'' 143/8'' 531/2'' 5.00 Approx. Wt. = 40 lbs. 170 Product Guide For photometric information please visit our website: www.americanelectriclighting.com LuxMaster® LPS Series LML LPS Area Lighting 55-180W LPS O R D E R I N G I N F O R M AT I O N Example: L M L 0 9 L R H 4 8 0 R 1 F P L C Wattage / Source Series LML Low Pressure Sodium LuxMaster Shoebox 55 09 13 18 55W 90W 135W 180W L LPS Refer to the ballast matrix on page 178 for compatibility. RH Reactor High Power Factor XH High Reactance / Lag High Power Factor Distribution Voltage Ballast 120 208 240 277 347 480 DT1 DT2 MT1 MT8 MT2 MT7 TT1 TT7 TT3 120V 208V 240V 277V 347V 480V Dual-tap 120/240 wired 120V Dual-tap 120/240 wired 240V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V R1 Roadway Type I Optics FP Flat Polycarbonate Options Paint1 (blank) BK GY WH Notes: Bronze (standard) Black Gray White 1 Other colors available; please contact your local American Electric Lighting representative Photocontrol Receptacle (blank) No Photocontrol Receptacle PR NEMA Photocontrol Receptacle Lamp LC Lamp Included, Clear Misc. NL NEMA Label on Housing See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 171 Accessories AVA I L A B I L I T Y 53-1-BZ2 153-1-BZ2 53-1-W-BZ2 153-1-W-BZ2 53-1-BZ-WM2 153-1-BZ-WM2 LMPBZ2 LMWBZ2 LMKBZ2 LMTBZ2 LM1BZ2 LM3BZ2 LM4BZ2 LM5BZ2 LM6BZ2 LM7BZ2 LM8BZ2 LM9BZ2 LM0BZ2 LMMBZ2 9401-H2 53-VS1 LS-HS2 LM-HS2 TMS-20-1902 TMS-25-1902 TMS-30-1902 TMS-20-2902 TMS-25-2902 TMS-30-2902 TMS-20-3902 TMS-25-3902 TMS-30-3902 TMS-20-4902 TMS-25-4902 TMS-30-4902 AVL-HS2 53 ◆ ◆ ◆ ◆ ◆ - 153 ◆ ◆ ◆ ◆ - AVL ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ LS ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ - LM ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ - LL ◆ ◆ ◆ - Notes: 1 Use with flat lens only 2 Standard finish is Dark Bronze; contact American Electric Lighting for other finishes Pole Top Tenon Adapter For AVL Tenon ID 2.378” 2.875 3.5” 4” 172 Product Guide Standard 4-1/4” Mounting Pattern 2@180 3@120 4@90 TMS-20-280 TMS-20-320 TMS-20-490 TMS-25-280 TMS-25-320 TMS-25-490 TMS-35-280 TMS-35-320 TMS-35-490 TMS-30-280 TMS-30-320 TMS-30-490 Optional 4-7/8” Mounting Pattern 2@180 3@120 4@90 T47-20-280 T47-20-320 T47-20-490 T47-25-280 T47-25-320 T47-25-490 T47-35-280 T47-35-320 T47-35-490 T47-30-280 T47-30-320 T47-30-490 For more information please visit our website: www.americanelectriclighting.com Accessories Mounting Hardware O R D E R I N G Catalog Number Item 9920-H Universal Wall Mount Designed for aluminum and steel with universal adjustment of 180° for yoke mounting. Furnished with all hardware except wall mounting bolts. D ATA Approx. Wt. (lbs) 1 Area Rectilinear Arm Field Installed 53-1-BZ 153-1-BZ A B C D 2.031” 2.781” 3.25” 8” 2.031” 3.531” 4” 10” NOTE: Pole must be drilled to match dimensions shown. 32 46 Area Wall Mount Bracket 53-1-W-BZ 153-1-W-BZ 53-1-BZ-WM 153-1-BZ-WM 53-VS A B C D 5.687” 4.687” 2.781” 2.031” 5.687” 4.687” 3.531” 2.031” NOTE: Pole must be drilled to match dimensions shown. Pole Mount Plate Pole mount comes with rectilinear arm. Polycarbonate Shield For flat lens only. See pages 259-264 for a complete listing of Frequently Ordered Products 32 46 Series 53 Series 153 7 5 Series 53 5 Product Guide 173 Accessories Steel Bracket - Prime Coated (For Horizontally Mounted Luminaires) M O U N T I N G Catalog Number 9401 O P T I O N S Item FABRICATED STEEL BRACKET — SINGLE ARM For mounting on 2'' (23/8'' OD) standard pipe or pole top tenon. 12'' spread. Effective Projected Area (Sq. Ft.) Approx. Wt. (lbs.) .4 10 See Isotach Wind Map, page 215 Note: Above brackets available with Galvanized Finish. To order add G suffix to catalog number. 174 Product Guide For photometric information please visit our website: www.americanelectriclighting.com Accessories M M OO UU NN TT II NN GG OO PP TT II OO NN SS 12'' Pole mount, secured with solid steel plate, attaches luminaire directly to square pole. Full length mounting screws secure luminaire, arm and pole. Square/round tenon adapter mounts on top of round or square pole for luminaire attachment. Makes a smooth transition from pole to luminaire. Available mounting arrangements listed below. Catalog Number - LMPBZ Wall mount arm secures luminaire to wall plate with full length mount screws. Full length mounting screws secure luminaire to arm and wall plate. Catalog Numbers LM5BZ Square LMTBZ Round 12'' Catalog Number - LMWBZ Adjustable knuckle for pole attachment of luminaire. Makes a smooth transition from pole to luminaire. 36'' 9-3/4'' Wraparound Yoke - Luminaire is suspended above mounting surface by mount and extends above poles. 273/8'' Catalog Constructable Option Catalog Number - LMKBZ Catalog Number LMTBZ LM1BZ LM2BZ LM3BZ LM4BZ LM5BZ LM6BZ LM7BZ LM8BZ LM9BZ LMRBZ Description Square Tenon with 1 Arm Square Tenon with 2 Arms at 90° Square Tenon with 2 Arms at 180° Square Tenon with 3 Arms Square Tenon with 4 Arms Round Tenon with 1 Arm Round Tenon with 2 Arms at 90° Round Tenon with 2 Arms at 180° Round Tenon with 3 Arms at 90° Round Tenon with 3 Arms at 120° Round Tenon with 4 Arms at 90° Mast arm mount - Luminaire is attached to curved mast arm for mounting to pole or structure. 3-5/8'' Catalog Number - LMMBZ See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 175 Area Lighting B A L L A S T M AT R I C E S AVL Watts 25S 25V 25M 31S 32M 35M 40S 40M 45M 75M XS XM 120 CA CA CA, SC CA SC SC CA CA, SC SC SC CA CA, SC 208 CA CA CA, SC CA SC SC CA CA, SC SC SC CA, CT CA, SC 220 CA CA SC CA CA CA, CT - 230 CA CA, SC - 240 CA CA CA, SC CA SC SC CA CA, SC SC SC 277 CA CA CA, SC CA SC SC CA CA, SC SC SC CA CA, SC, CT 480 CA CA CA CA SC SC CA CA, SC SC SC CA SC DT1 CA, CT CA SC CA SC SC CA CA, SC SC CA CA DT2 CA, CT CA SC CA SC SC CA CA, SC SC CA CA DT3 CT - DT4 CT - AVL continued Watts 25S 25V 25M 31S 32M 35M 40S 40M 45M 75M XS XM MT1 CA CA CA, SC CA SC SC CA CA, SC SC CA CA, SC MT2 CA CA CA, SC CA SC SC CA CA, SC SC CA CA, SC MT7 CA CA CA, SC CA SC SC CA CA, SC SC CA CA, SC MT8 CA CA CA, SC CA SC SC CA CA, SC SC CA CA, SC TT1 CA CA SC SC SC CA, CT CA, SC, CT SC CA CA TT3 CA CA SC SC SC CA, CT CA, SC, CT SC CA CA 208 XH, CA, CT, XN XH, CA, CT, XN CA, CT, XN, XH CA CA 220 CA - 230 RN, RH RN, RH - 240 XH, CA, CT, MR, XN XH, CA, CT, MR, XN CA, CT, XN, XH CA, CT, RN, RH CA 277 XH, CA, XN CA, XH, XN XN, XH, CA CA CA TT7 CA CA SC SC SC CA, CT CA, SC, CT SC CA CA 347 CA, CT CA SC SC SC CA, CT CA, SC,CT SC SC CA CA, CT LuxMaster® Series 53 Watts 07S 10S 15S 17V 17M 120 RH, CA, CT, RN, MR CA, CT, MR, RH, RN RN, RH, CA, CT XN, XH, CA, CT CA 480 DT1 DT2 MR XH, XN, CA, CT, MR XH, XN, CA, CT, MR CA CA, CT, XH, MR, XN CA, CT, MR, XH, XN CA XN,XH, CA, CT XN, XH, CA, CT CA,CT CT CT, CA CA CA CA LuxMaster® Series 53 continued Watts 07S 10S 15S 17V 17M 176 MT1 XH, XN, CA CA, XN, XH XN, XH, CA CA CA Product Guide MT2 XH, XN, CA, CA, XN, XH XN, XH, CA CA CA MT7 XH, XN, CA CA, XN, XH XN, XH, CA CA CA MT8 XH, XN, CA CA, XN, XH XN, XH, CA CA CA TT1 XN, XH XN, XH XN, XH - TT7 XN, XH XN, XH XN, XH - TT3 XN, XH XN, XH XN, XH - 347 XN, XH,CA,CT XN, XH XN, XH, CA - For photometric information please visit our website: www.americanelectriclighting.com DT3 MR CT - DT4 MR CT - Area Lighting B A L L A S T M AT R I C E S LuxMaster® Series 153 Watts 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 120 XH, CA, CT, MR, XN XN, CA, CT, MR, XH XH, XN, CA CA MR XN, CA, CT, MR, XH XH, XN, CA CA CA 208 CA, CT CA, CT CA CA CA, CT CA CA CA 240 RN, RH, CA, CT, MR RH, RN, CA, CT, MR RH, RN CA MR RH, RN, CA, CT, MR CA CA CA 277 CA, CT CA, CT CA CA CA, CT CA CA CA 347 CA CT CA - 480 CA, CT, MR CA, CT, MR CA MR CA, CT, MR CA CA DT1 XH, XN, CA, CT, MR XH, XN, CA, CT, MR CA CA MR CA, CT, MR CA CA CA DT2 XH,XN,CA,CT,MR XH,XN,CA,CT,MR CA CA MR CA,CT,MR CA CA CA DT3 MR MR CA MR MR CA - DT4 MR MR CA MR MR CA - LuxMaster® Series 153 continued Watts 20S 25S 25V 25M 31S 40S 40V 40M 23/24S MT1 CA, CT CA, CT CA CA CA, CT CA CA CA MT2 CA, CT CA, CT CA CA CA, CT CA CA CA MT7 CA, CT CA, CT CA CA CA, CT CA CA CA MT8 CA, CT CA, CT CA CA CA, CT CA CA CA TT1 CA CA CA CA - TT7 CA CA CA CA - TT3 CA CA CA CA - LuxMaster® Classic Series LS Watts 07S 10S 10V 15S 17V 17M 120 RH,CA,CT,RN,MR CA,CT,MR,RH,RN XH,XN,CA,CT RN,RH,CA,CT XN,XH,CA,CT CA 208 XH,CA,CT,XN XH,CA,CT,XN CA CA,CT,XN,XH CA CA 220 CA - 230 RN,RH RN,RH - 240 XH,CA,CT,MR,XN XH,CA,CT,MR,XN CA,CT RN,RH,CA,CT,XN,XH CA,CT,RN,RH CA 277 XH,CA,XN CA,XH,XN XN,XH,CA XN,XH,CA CA CA 480 MR CA CT CA CA,CT CA DT1 XH,XN,CA,CT,MR CA,CT,XH,MR,XN CT XN,XH,CA,CT CT CA DT2 XH,XN,CA,CT,MR CA,CT,MR,XH,XN CT,CA XN,XH,CA,CT CT,CA CA DT3 MR CT CT - DT4 MR CT CT - LuxMaster® Classic Series LS continued Watts 07S 10S 10V 15S 17V 17M MT1 XH, XN, CA CA, XN, XH CA XN, XH, CA CA CA MT2 XH, XN, CA CA, XN, XH CA XN, XH, CA CA CA MT7 XH, XN, CA CA, XN, XH CA XN, XH, CA CA CA MT8 XH, XN, CA CA, XN, XH CA XN, XH, CA CA CA TT1 XN, XH XN, XH XN, XH XN, XH - TT7 XN, XH XN, XH XN, XH XN, XH - TT3 XN, XH XN, XH XN, XH XN, XH - 347 XN, XH, CA, CT XN, XH XN, XH XN, XH, CA - See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 177 Area Lighting B A L L A S T M AT R I C E S LuxMaster® Classic Series LM Watts 20S 25S 25V 25M 40S 40V 40M 120 CA,CT,XN,XH CA,CT,XN,XH XN,XH,CA,CT CA,CT XH,XN,CA,CT,MR XH,XN CA,CT 208 CA,CT CA,CT CA CA CA,CT,MR CA,CT CA,CT 220 RH,CA,CT RH,,RN - 230 RN,RH RH,RN,CA,CT,MR RH,RN,CA,CT, CA,CT, 240 RN,RH,CA,CT,XN,XH RN,RH,CA,CT RN,RH,CA,CT CA,CT MR,CA,CT RH,CA,CT,RN CA,CT 277 CA,CT CA,CT CA CA CA,CT CA,CT 480 CA,CT CA,CT CA,CT CA,CT CA,CT,MR CA,CT, DT1 CA,CT,XN,XH XN,XH,CA,CT CA,CT CA,CT CA,CT,MR CA,CT CA,CT DT2 CA,CT,XN,XH XN,XH,CA,CT CA,CT CA,CT CA,CT,MR CA,CT CA,CT LuxMaster® Classic Series LM continued Watts 20S 25S 25V 25M 40S 40V 40M DT3 CT CT MR CA, CT - DT4 CT CT MR CA, CT - MT1 CA, CT CA, CT CA CA CA, CT, MR, RH, RN, XN, XH CA, CT, XN, XH, RN, RH CA, CT, XN, XH, RN, RH MT2 CA, CT CA, CT CA CA CA, CT, MR, RH, RN, XN, XH CA, CT, XN, XH, RN, RH CA, CT, XN, XH, RN, RH MT7 CA, CT CA, CT CA CA CA, CT, MR, RH, RN, XN, XH CA, CT, XN, XH, RN, RH CA, CT, XN, XH, RN, RH MT8 TT1 CA,CT CA CA,CT CA, CT CA CA CA CA, CT, MR, RH, RN, XN, XH CA, CT, XN, XH, RN, RH CA, CT, XN, XH, RN, RH - TT7 CA CA, CT CA - TT3 CA CA, CT CA - LuxMaster® Classic Series LL Watts XS XM 120 CA, CT CA, CT 208 CA, CT CA, CT 230 CA, CT CA, CT 240 CA, CT CA, CT 277 CA, CT CA, CT 480 CA, CT CA, CT DT1 CA, CT CA, CT DT4 CA, CT, XN, XH, RN, RH CA, CT, XN, XH, RN, RH MT1 CA, CT, XN, XH, RN, RH CA, CT, XN, XH, RN, RH MT2 CA, CT, XN, XH, RN, RH CA, CT, XN, XH, RN, RH LuxMaster® LPS Luminaire Series LML Watts 55L 09L 13L 18L 178 120 XH XH XH XH 208 XH XH XH XH 240 XH XH XH XH Product Guide 277 XH XH XH XH 480 RH XH DT1 XH XH XH XH DT2 XH XH XH XH MT1 XH XH XH XH MT2 XH XH XH XH MT7 XH XH XH XH MT8 XH XH XH XH TT1 XH XH TT3 XH XH TT7 XH XH 347 XH XH For photometric information please visit our website: www.americanelectriclighting.com MT7 CA ,CT, XN, XH, RN, RH CA, CT, XN, XH, RN, RH 347 CA CA, CT CA CA - FLOODLIGHTING Compact Flood Series 51 . . . . . . . . . . . . . . . . . .180 UltraFlood™ Series 75 . . . . . . . . . . . . . . . . . . . .182 UltraFlood™ Series 77 . . . . . . . . . . . . . . . . . . . . .184 Quartz Flood Series 570 . . . . . . . . . . . . . . . . . . .186 Quartz Flood Series 474 . . . . . . . . . . . . . . . . . . .187 AmeriSport™ Series ASP . . . . . . . . . . . . . . . . .188 Sportslighting Series SPF . . . . . . . . . . . . . . . . .190 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192 Ballast Matrices . . . . . . . . . . . . . . . . . . . . . . . . . .197 American Electric Lighting™ Compact Flood Series 51 Heavy Duty Floodlight 50-400W HPS, 175-400W MH, 100-400W MV, 250/400 Dual-Watt HPS/MH P R O D U C T O V E R V I E W Features: Compact design for an unobtrusive presence in the environment. Wide NEMA beam patterns available with horizontal lamp. Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance. Single door access to lamp and electrical components for quick, easy installation and servicing. Pivoting painted yoke is standard; tenon, galvanized and painted wraparound yoke mounting options are available for precise aiming. UL listing is standard. For easy maintenance, tool-less entry is available. Lens is thermal shock and impact resistant tempered glass. Hydroformed reflector. Applications: Auto dealerships Schools Construction sites Recreational areas Storage yards Office buildings Airports All electrical components warranted by American Electric Lighting's 6-year guarantee. Churches Industrial sites Shopping centers Parking lots Substations Building facades Suitable for -30°C MH & MV / -40°C HPS. Note: ED28 lamp must be used with 400W Metal Halide and Mercury Vapor luminaires. DIMENSIONS 15.5" (394) 6" (152) 17" (432) 16.25" (413) 6" (152) 17" (432) 15.5" (394) 6" (152) 22.5" (572) Effective Projected Area (EPA) The EPA for the Compact flood Series 51 is 1.9 sq. ft Approx. Wt. = 30 lbs. 180 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Compact Flood Series 51 Heavy-Duty Floodlight 50-400W HPS, 175-400W MH, 100-400W MV, 250/400 Dual-Watt HPS/MH O R D E R I N G I N F O R M AT I O N Example: 5 1 4 0 S C A M T 1 7 6 W Y 0 6 4 3 Wattage / Source Series 51 Compact Flood 05 07 10 13 14 15 17 20 25 31 40 23 24 S HPS M MH V MV 50W 70W 100W 100/150W wired 100W 100/150W wired 150W 150W 175W 200W 250W 310W 400W1 250/400W1 wired 250W 250/400W1 wired 400W 120 208 220 240 277 347 480 MT1 MT2 MT8 MT7 TT1 TT7 TT3 DT1 120V 208V 220V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 240V Multi-tap wired 208V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual Tap 120/240 wired 120 DT2 Dual-tap 120/240 wired 240 DT3 Dual-tap 240/480 wired 240 DT4 Dual-tap 240/480 wired 480 RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA (Auto Reg) CT CWI SC SCWA MR Mag Reg (3 Coil) Refer to the ballast matrix on page 197 for compatibility. Options Maximum number of options is eight, for more options please contact your local American Electric Lighting representative Starter7 Mounting (blank) Open Board (standard) (blank) Yoke Mount2 EC Encapsulated Plug-In TM Tenon Slipfitter2 OP Open Board Plug-In WY Wraparound Yoke2 SN No Ignitor (using self-igniting lamp) GW Galvanized Wraparound Yoke Paint3 (blank) BK GY WH Bronze (standard) Black Gray White Terminal Block4 (blank) Hard Wired (standard) TB Terminal Block T2 Wired to L1 and L2 T3 3-Wire Operation (L1, N, L2 positions) Listing (blank) CS XL UL Listed (standard) CSA Certified No Listing Photocontrol Receptacle (NEMA twist-lock) (blank) Photocontrol Receptacle NR No Photocontrol Receptacle5 PB Phosphor Bronze Contacts Lamp LC LD LG Lamp Included, Clear Lamp Included, Deluxe Self-Igniting Lamp6 Fusing8 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Cord Length** 04 4’ 05 5’ 06 6’ 08 8’ 10 10’ 12 12’ 15 15’ 20 20’ 25 25’ 30 30’ Misc. PC VS SS 5H NL TL PGS GS SH Cord Type** 63 16-3 44 14-49 43 14-3 23 12-3 NEMA Beam Pattern Voltage Ballast Horizontal Lamp 76 7H x 6V 77 7H x 7V Refer to Optic Distribution Matrix below for compatibility. Notes: 1 400 MH requires ED28 reduced-jacket lamp 2 Painted to match fixture 3 Other colors available; please contact your local American Electric Lighting representative 4 Voids UL, CSA listings 5 PB,PC and SH not available with NR option 6 Requires SN options 7 HPS only 8 Voids UL and CSA listing, not available in MT, TT and DT voltage options 9 For 3-wire operation and ground 10 Limited availability; please contact your local American Electric Lighting representative 11 Ships separately **Cord length and type should be combined to form one number. Ex: 0643 Photocontrol Included per Voltage Specified Vandal Shield7 Stainless Steel (external) 50 Hertz Ballast Frequency10 NEMA Label Tool-less Entry Ballistic Shield Glare Shield11 Shorting Cap Optic Distribution 15S 20S 31S 40S 17M 25M 40M 77 ◆ ◆ ◆ ◆ ◆ ◆ ◆1 76 ◆ ◆ ◆ ◆ ◆ ◆1 Notes: 1 Use ED28 lamp only See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 181 UltraFlood™ Series 75 Heavy Duty Floodlight 100-400W HPS; 100-400W MV; 175/400W MV; 250/400 Dual-Watt HPS/MH P R O D U C T O V E R V I E W Features: NEMA beam patterns available in a variety of options including horizontal and vertical lamps. Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance. Door is hinged and easily removable for quick maintenance. Fully pivoting painted yoke is standard, tenon and galvanized yoke mounting options are available for precise aiming. UL listing is standard. For easy of maintenance, tool-less entry and ballast tray are available options. Lens is thermal shock and impact resistant tempered glass. Hydroformed reflector. Suitable for -30°C MH & MV / -40°C HPS. Applications: Auto dealerships Schools Construction sites Recreational areas Storage yards Office buildings Airports All electrical components warranted by American Electric Lighting's 6-year guarantee. Churches Industrial sites Shopping centers Parking lots Substations Building facades DIMENSIONS 17.75" (451) 7.00" (178) 23.00" (584) 1.00" (25) 2.00" (51) 19.50" (495) 17.75" (451) 2.00" (51) .44" (11) Dia. .78" (20) Dia. 7.00" (178) 1.00" (25) 2.00" (51) 21.13" (537) 19.50" (495) Effective Projected Area (EPA) The EPA for the UltraFlood™ Series 75 is 2.75 sq. ft. Approx. Wt. = 37 lbs. 182 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com UltraFlood™ Series 75 Heavy-Duty Floodlight 100-400W HPS; 100-400W MV; 175/400W MV; 250/400 Dual-Watt HPS/MH O R D E R I N G I N F O R M AT I O N Example: 7 5 4 0 M C A M T 1 6 6 0 6 4 3 L C T L P C Series 75 UltraFlood Wattage / Source 10 15 17 20 25 31 40 23 100W 150W 175W 200W 250W 310W 400W 250/400W wired 250W 24 250/400W wired 400W S HPS M MH V MV RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA (Auto Reg) CT CWI SC SCWA MR Mag Reg (3 Coil) Refer to the ballast matrix on page 198 for compatibility. Options Maximum number of options is eight, for more options please contact your local American Electric Lighting representative Mounting (blank) Yoke Mount (standard)1 YG Wraparound Yoke Galvanized TM Tenon Slipfitter1 Lamp LC LD LG Lamp Included, Clear Lamp Included, Deluxe Self-Igniting Lamp6 Paint2 (blank) BK GY WH Fusing7 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Bronze (standard) Black Gray White Terminal Block3 (blank) Hard Wired (standard) TB Terminal Block Factory Wire T2 Wired to L1 and L2 Position T3 3-Wire Operation (L1, N, L2 Position) Listing (blank) CS XL UL Listed (standard) CSA Certified No Listing Photocontrol Receptacle (blank) Photocontrol Receptacle (standard) NR No Photocontrol Receptacle PB Phosphor Bronze Contacts4 Starter5 (blank) EC OP SN Open Board (standard) Encapsulated Plug-In Open Board Plug-In No Ignitor (using self-igniting lamp) PP SS 5H NL PGS WG VS SH Vertical Lamp 76 7H - 6V 66 6H - 6V Horizontal Lamp H6 6H - 6V 120 208 220 240 277 347 480 MT1 MT2 MT8 MT7 TT1 TT7 TT3 DT1 120V 208V 220V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 240V Multi-tap wired 208V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual-tap 120/240 wired 120V DT2 Dual-tap 120/240 wired 240V DT3 Dual-tap 240/480 wired 240V DT4 Dual-tap 240/480 wired 480V Refer to Optic Distribution Matrix below for compatibility. Notes: Cord Length* 04 4’ 05 5’ 06 6’ 08 8’ 10 10’ 12 12’ 15 15’ 20 20’ 25 25’ 30 30’ Misc. TL PC NEMA Beam Pattern Voltage Ballast Cord Type* 63 16-3 44 14-48 43 14-3 23 12-3 *Cord length and type should be combined to form one number. Ex: 0423 1 Painted to match fixture 2 Other colors available, please contact your local American Electric Lighting representative 3 Voids UL and CSA Listing 4 PB, PC, and SH not available with NR option 5 HPS only 6 Requires SN option 7 Voids UL and CSA listing, not available in MT, TT, and DT voltages 8 For 3-wire operation and ground 9 Limited availability, please contact your local American Electric Lighting representative 10 Ships separately Optic Distribution Tool-less Entry Photocontrol Included per Voltage Specified Removable Power Pad Stainless Steel Fastener (external) 50 Hertz Ballast Frequency9 NEMA Label Ballistic Shield10 Wire Guard10 Vandal Shield10 Shorting Cap See pages 259-264 for a complete listing of Frequently Ordered Products 20S 25S 40S 17M 25M 40M 17V 25V 40V 76 ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ 66 - ◆ ◆ ◆ ◆ ◆ ◆ 56 ◆ ◆ ◆ - H6 ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ Product Guide 183 UltraFlood™ Series 77 Heavy-Duty Floodlight 400-1000W HPS; 400-1000W MH/MV P R O D U C T O V E R V I E W Features: NEMA beam patterns available in a variety of options with horizontal lamp. Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance. Door is hinged and easily removable for quick maintenance. Fully pivoting painted yoke is standard, tenon and galvanized yoke mounting options are available for precise aiming. UL listing is standard. For easy maintenance, tool-less entry is available. Suitable for -30°C MH & MV / -40°C HPS. Lens is thermal-, shock- and impact-resistant tempered glass. All electrical components warranted by American Electric Lighting's 6-year guarantee. Applications: Churches Industrial sites Shopping centers Parking lots Substations Building facades Auto dealerships Schools Construction sites Recreational areas Storage yards Office Buildings Airports DIMENSIONS 8-5/8" (219) 21-7/16" (545) 21-7/16" (545) 13" (330) 23-7/16" (595) Front View, Yoke Mount 5-1/2" (140) Side View, Tenon Mount 2" (51) 2" (51) 7/16" (11) Dia. 25/32" (20) Dia. Hole Spacing, Yoke Mount Effective Projected Area (EPA) The EPA for the UltraFlood™ Series 77 is 3.97 sq. ft. Approx. Wt. = 65 lbs. 184 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com UltraFlood™ Series 77 Heavy-Duty Floodlight 400-1000W HPS; 400-1000W MH/MV O R D E R I N G I N F O R M AT I O N Example: 7 7 X I M C A M T 7 7 6 T M Wattage / Source Series 77 UltraFlood 40 400W S HPS 75 750W M MH X1 1000W V MV Refer to the ballast matrix on page 198 for compatibility. CA CT SC MR RN RH XN XH CWA (Auto Reg) CWI SCWA (Pulse Start) Mag Reg CWA (Auto Reg) CWI SCWA (Pulse Start) Mag Reg Options Maximum number of options is eight, for more options please contact your local American Electric Lighting representative Mounting (blank) Yoke Mount (standard)1 YG Yoke Galvanized TM Tenon Slipfitter1 Paint2 (blank) BK GY WH Bronze (standard) Black Gray White Terminal Block3 (blank) Hard Wired (standard) TB Terminal Block T2 Wired to L1 and L2 T3 3-Wire Operation (L1, N, L2 Position) Listing (blank) CS XL UL Listed (standard) CSA Certified No Listing Photocontrol Receptacle (blank) Photocontrol Receptacle NR No Photocontrol Receptacle4 PB Phosphor Bronze Contacts Lamp LC LD Fusing5 SF DF SS 5H NL PGS WG VS SH NEMA Beam Pattern 120 208 220 240 277 347 480 MT1 MT2 MT8 MT7 TT1 TT7 TT3 DT1 120V 208V 220V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 240V Multi-tap wired 208V Multi-tap wired 277V Tri-tap wired 120V Tri-tap wired 277V Tri-tap wired 347V Dual-tap 120/240 wired 120 DT2 Dual-tap 120/240 wired 240 DT3 Dual-tap 240/480 wired 240V DT4 Dual-tap 240/480 wired 480V Horizontal Lamp 65 6H - 5V 66 6H - 6V 76 7H - 6V Refer to Optic Distribution Matrix below for compatibility. Notes: Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Cord Length* 04 4’ 05 5’ 06 6’ 08 8’ 10 10’ 12 12’ 15 15’ 20 20’ 25 25’ 30 30’ Misc. TL PC Voltage Ballast 1 Painted to match fixture 2 Other colors available; please contact your local American Electric Lighting representative 3 Voids UL and CSA certification 4 PB, PC and SH not available with NR option 5 Voids UL and CSA listing; not available in MT, TT and DT voltages 6 For 3-wire operation and ground 7 Limited availability, please contact your local American Electric Lighting representative 8 Ships separately Cord Type* 63 16-3 44 14-46 43 14-3 23 12-3 PW Pre-wire (Slipfitter only) *Cord length and type should be combined to form one number. Ex: 0643 Optic Distribution Tool-less Entry Photocontrol Included per Voltage Specified Stainless Steel fasteners (external) 50 Hertz Ballast Frequency7 NEMA Label Ballistic Shield8 Wire Guard8 Vandal Shield8 Shorting Cap X1S X1M 65 ◆ 66 ◆ - 76 ◆ Lamp Included, Clear Lamp Included, Deluxe See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 185 Quartz Flood Series 570 Floodlight 500W Quartz P R O D U C T O V E R V I E W Features: Rugged, die-cast aluminum housing is powder-coated for durability and corrosion resistance; bronze is standard color. Single door access to lamp and electrical components for quick, easy installation and servicing. Suitable for -30°C MH & MV / -40°C HPS. UL listing is standard. Lens is thermal-, shock- and impact-resistant tempered glass. Applications: Transportation terminals Building facades Sports lighting Parking lots Industrial areas Commercial areas Residential areas Security lighting Fixture Available 570-61/L Clear lamp included (120V) DIMENSIONS 9-1/2" (241) 7" (178) 3-1/2" (89) 7" (178) Effective Projected Area (EPA) The EPA for the Floodlight, Series 570 is 0.72 sq. ft. Approx. Wt. = 3.5 lbs. 186 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com Quartz Flood Series 474 Floodlight 1500W Quartz O R D E R I N G I N F O R M AT I O N Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance, bronze is standard color. Single door access to lamp and electrical components for quick, easy installation and servicing. Permanently attached bezel is secured by twin captive spring latches. UL listing is standard. Lens is thermal-, shock- and impact-resistant tempered glass for lamp protection. Applications: Transportation terminals Building facades Sportslighting Parking lots Industrial areas Commercial areas Residential areas Security lighting Fixtures Available 474-61/L-240V 474-61/L-277V Lamp included (240V) Lamp included (277V) DIMENSIONS Effective Projected Area (EPA) The EPA for the Floodlight, Series 474 is 1.13 sq. ft. Approx. Wt. = 5.5 lbs. See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 187 AmeriSport™ Series ASP Sportslighting 400-1500W MH W PP RR OO DD UU CC TT OO VV EE RR VV II EE W Features: NEW Two-piece, die-cast aluminum ballast housing mounted to galvanized steel trunnion. Ballast is removable and hinged with captive fastener. Steel trunnion features vertical and horizontal aiming scale with vertical repositioning stop. All external hardware is stainless steel. White corrosion-resistant polyester powder finish standard; other architectural colors available. Heavy-gauge anodized reflector with six distributions available. "Flux manager" available for optimal glare and spill light control. Transverse mounting of lamp. Lamp support included. Optical chamber sealed to inhibit entrance of contaminants. Hinged lens is thermal-, shock- and impact-resistant tempered glass. Lens frame is galvanized and secured by stainless steel spring clips for servicing of lamp. US. Patent no. 6,190,023. Canada Patent no. 2,212,014. Fixture mounted by securing trunnion directly to cross arm. Mounting hardware provided. Suitable for -30°C MH & MV / -40°C HPS. Applications: UL listed, suitable for wet locations. Below horizontal aiming orientation only. Listed and labeled to comply with Canadian Standards. Stadiums Sports fields Arenas Tracks Courts All electrical components warranted by AEL’s 6-year guarantee. DIMENSIONS 20 (50.8) 24-1/2 (62.2) Effective Projected Area (EPA) The EPA for the Sports Floodlight Series SF is 2.39 sq. ft. Approx. Wt. = 55 lbs. 188 Product Guide For photometric information, please visit our website, www.americanelectriclighting.com AmeriSport™ Series ASP Sportslighting 400-1500W MH O R D E R I N G I N F O R M AT I O N Example: A S P X 5 M C A M T 1 G N ASP AmeriSport 40 400W X1 1000W X5 1500W Voltage Ballast Wattage / Source Series M Metal Halide CA CWA SC SCWA (Pulse Start)1 CT CWI2 120 208 220 240 277 347 480 MT1 MT8 MT2 MT7 TT1 TT7 TT3 120V 208V 220V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Tri-tap wired 120 Tri-tap wired 347 Tri-tap wired 277 Optics G General purpose H Heavy-duty Distribution N M W NX Narrow Beam Medium Beam Wide Beam Narrow Beam with Flux Manager DX Medium Beam with Flux Manager WX Wide Beam with Flux Manager Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Listing (blank) UL Listed (standard) CS CSA Certified3 XL No Listing Notes: 1 400W MH only 2 Available in 208 and 240V only 3 Consult factory for CSA availability 4 Single tap only 5 Limited availability, please contact your local American Electric Lighting representative 6 Must use with heavy-duty optical 7 Must use mating receptacle, provided by others 8 Not available with 1500W, 120V 9 Use with pre-wired gauges and crossarms 10 For use with 0363 cord length and type only Fusing4 SF Single Fuse (120, 277, 347V) DF Double Fuse (208, 220, 240, 480V) Cord Length* 03 3' Cord 05 5' Cord 08 8' Cord Cord Type* 23 12-3 SEO Cord 43 14-3 SEO Cord 63 16-3 SEO Cord *Cord length and type should be combined to form one number. Ex: 0523 Lamp LC Lamp Included, Clear (ships separately) Frequency 5H 50 Hertz Ballast Frequency5 Filter CF Charcoal Filter6 Quartz Restrike QS Quartz Restrike (Lamp not included) Connector 3P 3-Prong Plug7,8,9,10 Ordering/Packaging Options To accommodate the product’s physical configuration as well as a range of customer handling and processing needs, alternative ordering/packaging methods are available. Example: (21) ASP X5M CA MT1 GN This can be ordered/packaged as: 1. Standard Packaging (Optimized form) To order, use single catalog number shown in example above. Fixture ships as multiple components using optimized packaging. Example ships as: (Qty 21) ASP X5M CA MT1 HSG (21 housing cartons) (Qty 20) ASP GN J4 (5 cartons of 4 reflectors) (Qty 1) ASP GN U (1 carton of 1 reflector) 2. Component Packaging. Housings ship in unit cartons. To order, specify package multiples you prefer (using components from the above list). Fixtures ship as separate components in package multiples you choose. Example: (Qty 21) ASP X5M CA MT1 HSG (21 cartons of 1 housing) ASP 20B J4 (5 cartons of 4 reflectors) and ASP 20B U (1 carton of 1 reflector) See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 189 Sportslighting Series SPF High-Intensity Sports Floodlight 400W HPS, 1000W HPS, 400W MH, 1000W MH, 1500W MH P R O D U C T O V E R V I E W Features: NEW Heavy-gauge, hydroformed, aluminum ballast housing is mounted to integral die-cast monoframe with horizontal degree aiming scale and repositioning locator. Die-cast aluminum socket housing provides vertical aiming adjustment, complete with degree aiming scale and repositioning stop. Heavy-gauge, anodized, aluminum reflectors provide a range of NEMA beam spreads. Optical chamber is sealed to inhibit entrance of contaminants. Hinged lens is heavy-duty thermal-, shock- and impact-resistant tempered glass. Adjustable mounting bracket standard. Porcelain, mogul-base socket with copper alloy, nickel-plated screw shell and center contact. UL listed 1500W, 600V. Fixture is mounted by securing the integral cross-arm mounting bracket directly to the cross arm. No additional adapters are required. A 5/8"-11UNC mounting bolt is provided. Exposed bolt length is 1-1/2". UL listed, suitable for wet locations. Listed and labeled to comply with Canadian Standards. Suitable for -30°C MH & MV / -40°C HPS. Optional painted heavy-duty reflector shroud available to protect the reflector. Applications: All electrical components warranted by AEL’s 6-year guarantee. Stadiums Sports fields Arenas Tracks Courts DIMENSIONS D L Dimensions EPA: NEMA 2,3: NEMA 4,5,6: Diameter: NEMA 2,3: NEMA 4,5,6: Length: NEMA 2,3: NEMA 4,5,6: Weight: 53 lbs. 190 Product Guide 2.9 ft.2 (.27 m2) 2.5 ft2 (.23 m2) 23-1/8 (58.7) 21-1/2 (54.6) 30 (76.2) 31-1/2 (80) 24 Kg. For photometric information, please visit our website, www.americanelectriclighting.com Sportslighting Series SPF High-Intensity Sports Floodlight 400W HPS, 1000W HPS, 400W MH, 1000W MH, 1500W MH O R D E R I N G I N F O R M AT I O N Example: S P F X 5 M C A M T 1 5 5 Wattage / Source Series SPF Sports floodlight 40 400W X1 1000W X5 1500W1 Voltage Ballast S HPS M MH CA CWA SC SCWA (Pulse Start)2 CT CWI3 120 208 220 240 277 347 480 MT1 MT8 MT2 MT7 Optics 120V 208V 220V 240V 277V 347V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V 22 33 44 55 66 2Hx2V 3Hx3V 4Hx4V 5Hx5V 6Hx6V Options Maximum number of options is six, for more options please contact your local American Electric Lighting representative Listing (blank) UL Listed (standard) CS CSA Certified4 Fusing5 SF Single Fuse (120, 277, 347V) DF Double Fuse (208, 220, 240, 480V) Lamp LC Lamp Included, Clear (ships separately) Coating TC Non-stick protective coating, black only Aiming AH Above Horizontal Filter CF Charcoal Filter12 Quartz QS Quartz Restrike13 *Cord length and type should be combined to form one number. Ex: 0523 Shield GS Glare Shield HG Hail Shroud and Glare Shield RS Reflector (Hail) Shroud7 Louver LV Internal Louver Bolt LB Extended Bolt for Wood Crossarm Support LT Lamp Support Connector 3P 3 Prong Plug8,9,10,11 1 2 3 4 4 5 6 7 8 9 10 11 12 13 Cord Length* Cord Type* 23 12-3 SEO Cord 03 3' Cord 43 14-3 SEO Cord 05 5' Cord 63 16-3 SEO Cord 08 8' Cord Frequency 5H 50 Hertz Ballast Frequency6 Notes: Metal Halide only 400W MH Only Available in 208 and 240V only. Not available in HPS. Consult factory for CSA availability Must use mating receptacle, provided by others Available in single tap only Limited availability, please contact your local American Electric Lighting representative Heavy-duty anodized aluminum shroud Must use mating receptacle, provided by others Use with prewired cage and crossarms For use with 0363 cord length and type only Not available with 1500W, 120V For use with reflector shroud (RS option) only Lamp not included Ordering/Packaging Options To accommodate the product’s physical configuration as well as a range of customer handling and processing needs, alternative ordering/packaging methods are available. Example: (21) SPF X5M CA MT7 33 This can be ordered/packaged as: 1. Standard Packaging (Optimized Form) To order, use single catalog number shown in example above. Fixture ships as multiple components using optimized packaging. Example ships as: (Qty 21) SPF X5M CA MT7 N3 HSG (21 housing cartons) (Qty 20) SPF 20B J4 (5 cartons of 4 reflectors) (Qty 1) SPF 20B U (1 carton of 1 reflector) 2. Component Packaging. Housings ship in unit cartons. To order, specify package multiples you prefer (using components from the above list). Fixtures ship as separate components in package multiples you choose. Example: (Qty 21) SPF X5M CA MT7 N3 HSG (21 cartons of 1 housing) SPF 20B J4 (5 cartons of 4 reflectors and SPF 20B U (1 carton of 1 reflector) See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 191 Accessories G L A R E S H I E L D S Catalog Number Approx. Wt. (lbs.) Item 6" (152) 75-GS 75-VS 14-3/4" (375) 75-WG ULTRA FLOOD GLARE SHIELD Manufactured of corrosion-resistant aluminum. For use with Ultra Flood, Series 75. Standard finish is bronze. POLYCARBONATE VANDAL SHIELD 2 ULTRA FLOOD GLARE SHIELD Manufactured of corrosion-resistant aluminum. For use with Ultra Flood, Series 77. Standard finish is bronze. POLYCARBONATE VANDAL SHIELD 2 COMPACT FLOOD GLARE SHIELD Manufactured of corrosion-resistant aluminum. For use with Series 51. Standard finish is bronze. 2 1/2" (13) (152) 77-GS 15-7/8" (403) 77-VS 7/8" (21) 9.5" 4.5"(114) (241) 51-GS 17" (178) 75 PGS 40W 77 PGS X1W 51 PGS 40W Ballastic Shield Notes: Floodlighting 51-GS1 75-GS1,2 75-VS2 75-WG2 77-GS1,2 77-VS2 192 Product Guide 51 ◆ - 75 ◆ ◆ ◆ - 77 ◆ ◆ 1 2 For other finishes, please contact your local American Electric Lighting representative (standard finish is noted on accessory details, pg 193-196) Wire guards, vandal shields and glare shields cannot be used simultaneously For photometric information, please visit our website, www.americanelectriclighting.com Accessories For Mounting to Wood Poles S T E E L Catalog Number M O U N T I N G Effective Projected Area (Sq. Ft.)* Approx. Wt. (lbs.) SINGLE-UNIT BRACKET — Manufactured of 2” steel pipe with a minimum yield of 35,000 PSI. Requires two 1/2” lag screws, one 5/8” through-bolt and one 2” square flat washer. Prime-coated finish. .7 5 SINGLE-UNIT BRACKET — Manufactured of 2” steel pipe with a minimum yield of 35,000 PSI. Requires two 1/2” lag screws, one 5/8” through-bolt and one 2” square flat washer. Prime-coated finish. .7 13 SINGLE-UNIT BRACKET — Fixture bracket is 3”- 3 5/16” angle steel with 3/4” - 11/2” steel bolts. Unit of 2'' steel pipe with minimum yield strength of 35,000 PSI. Requires two 1/2” lag screws, one 5/8” through-bolt and one 2” square flat washer. Prime-coated finish. .8 141/4 TWIN-UNIT BRACKET — Each fixture bracket is 3”- 3 .8 271/4 TWIN-UNIT BRACKET — Manufactured of 2” steel pipe with a minimum yield strength of 35,000 PSI. Requires two 1/2” lag screws, one 5/8” through-bolt and one 2” square flat washer. Prime-coated finish. 1.4 24 THREE- UNIT BRACKET — Manufactured of 2” steel pipe with minimum yield strength of 35,000 PSI. Requires two 1/2” lag screws, one 5/8” through-bolt and one 2” square flat washer. Prime-coated finish. 1.9 27 Item 9201 B R A C K E T S 18'' 9254 23'' 87/8'' 9204 9205 5/16” angle steel with 3/4” - 11/2” steel bolts. Unit of 2” steel pipe with minimum yield strength of 35,000 PSI. Requires two 1/2” lag screws, one 5/8” through-bolt and one 2” square flat washer. Prime-coated finish. 9252 9252-G (Galvanized) 9253 9253-G (Galvanized) NOTE: Above brackets available with GALVANIZED FINISH; to order add -G suffix to catalog number. (Example: 9252-G.) Floodlighting 92011,2,4 92541,2,4 92041,2,4 92051,2,3 92521,2,3 9252-G1,2,4 92531,2,4 9253-G1,2,4 51 ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ 75 ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ 77 ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ Footnotes 1 2 3 4 Designed to accommodate fixtures with a max. weight of 65 lbs. and an epa of 4.0 For other finishes, please contact your local American Electric Lighting representative (standard finish is noted above) Yoke mount only Tenon mount only See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 193 Accessories M O U N T I N G H A R D W A R E Catalog Number 9902-H ALUMINUM POLE-TOP MOUNT Slipfitter mounting. Positive three-point mounting support and corrosion-resistant hardware. Fits 2” or 21/2” pipe (2” pipe intrudes 31/16”, 21/2” pipe intrudes 23/4”.) Furnished with mounting bolts, set screws and compression fitting for cable entry. Top cover removable for wiring. 3 9906 PIPE CLAMP MOUNT Plated steel and cast aluminum clamp mount with corrosion-resistant hardware for 11/2” or 2” pipe installations. 3 9909 PIPE CLAMP MOUNT Plated steel and cast aluminum clamp mount with corrosion-resistant hardware for 3” pipe installations. 5 Notes: Floodlighting 99021 99061 99091 194 Approx. Wt. (lbs.) Item Product Guide 51 ◆ ◆ ◆ 75 ◆ ◆ ◆ 77 ◆ ◆ ◆ 1 For other finishes, please contact your local American Electric Lighting representative (standard finish is noted above) For photometric information, please visit our website, www.americanelectriclighting.com Accessories For Mounting to Steel Poles S T E E L Catalog Number M O U N T I N G B R A C K E T S Effective Projected Approx. Area (Sq. Ft.) Wt. ( lbs.) Item 9333 THREE-ARM POLE-BRACKET—12” spread, arms @ 120° 2” (23/8” OD) standard pipe tenon and slipfitter base for mounting to standard 2” pipe tenons. Prime-coated finish. 1.2 34 9343 FOUR-ARM POLE-TOP BRACKET—48” spread, arms @ 90°, 2” (23/8” OD) standard pipe tenon and slipfitter base for mounting to standard 2'' pipe tenons. Prime-coated finish. .90 45 9352 TWO-ARM POLE-TOP BRACKET — 30” spread, 2” (23/8” OD) standard pipe tenon and slipfitter base for mounting to standard 2” pipe tenons. Prime-coated finish. .87 21 9353 THREE-ARM POLE-TOP BRACKET — 30” spread between tenons, 2” (23/8” OD) standard pipe tenon and slipfitter base for mounting to standard 2” pipe tenons. Prime-coated finish. 1.7 34 9354 FOUR-ARM POLE-TOP BRACKET — 30” spread between tenons, 2” (23/8” OD) standard pipe tenon and slipfitter base for mounting to standard 2” pipe tenons. Prime-coated finish. 2.3 45 NOTE: Above brackets available with GALVANIZED FINISH; to order add -G suffix to catalog number. (Example: 9252-G) For Steel, Aluminum, Fiberglass and Wood Poles refer to the Pole section or call your local American Electric Lighting representative. Floodlighting 93331,2 93431,2 93521,2 93531,2 93541,2 Notes: 51 ◆ ◆ ◆ ◆ ◆ 75 ◆ ◆ ◆ ◆ ◆ 77 ◆ ◆ ◆ ◆ ◆ 1 2 For other finishes, please contact your local American Electric Lighting representative (standard finish is noted above) Tenon mount only See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 195 Options and Accessories A S P CF ACRA ACRA45 LV ARWB ASAB ASPMB ATS ACRW2 ACRW3 ACRW4 / S P F ASP ■ ❑ N/A N/A ❑ ❑ ❑ ■ ❑ ❑ ❑ Charcoal filter Crossarm adapter for horizontal mounting Crossarm adapter for horizontal mounting 45° Internal bottom louver Radius wall bracket. Standard finish is dark bronze Steel angle bracket. Standard finish is dark bronze Pipe/wood/pole/wall mounting bracket. Mounts to 2” schedule 40 pipe Tenon slipfitter, fits 2-3/8” to 2-7/8” OD tenon 2-light wood pole 3-light wood pole 4-light wood pole SPF ■ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ = Available as an option, shipped installed ❑ = Available as an accessory, shipped separately 3-1/4" (8.3cm) ARWB ATS 5/8" Clearance Hole Furnished with weather-tight cord grip for 14-3 SO cord. (Grip for 12-3 SO optional.) 4-7/8" (12.4cm) Wire Access 4" (10.2cm) ACRA 5/8" x 1" hex bolt and lockwasher furnished 5/8" x 1" hex bolt and lockwasher furnished 1-1/4" (3.2cm) ACRA45 Fixture yoke Pivot slot for 1/2" bolt (not provided) 00 00 00 Floodlight yoke Pivot hole for 5/8" bolt (not rovided) 00 Degree markings ACRW2 00 00 00 6" (15.2cm) 00 00 00 4-1/2" (11.4cm) 00 Pivot slot for 1/2" bolt Pivot hole for 5/8" bolt (not provided) Degree markings ACRW3 36" (91.4cm) ACRW4 66" (167.6cm) ASMB 5/8" x 1" hex bolt and lockwasher furnished 8-11/16" (22.1cm) 1/2" x 1-1/2" hex bolt and flat washer furnished 5/8" x 1-1/2" bolt, lockwasher and nut furnished 11/16" diameter hole for 5/8" thru-bolt 4" (10.2cm) 12-1/2" (31.8cm) (2) 3/8" U-bolt furnished with nuts and washers Product Guide ASAB 4-3/16" (10.6cm) 4-3/4" (12.1cm) 3-3/8" (8.6cm) 196 96" (243.8cm) Fits 2" or 2-1/2" pipe (horizontal or vertical) For photometric information, please visit our website, www.americanelectriclighting.com 20-1/8" (51.1cm) 9/16" diameter holes for lag bolts (not provided) Floodlighting B A L L A S T M AT R I C E S Series 51 Watts 120 05S RH, RN 07S RH, CA, CT, RN, MR 10S CA, CT, MR, RH, RN 10V XH, XN, CA, CT 15S RN, RH, CA, CT, MR 17V XN, XH, CA ,CT 17M CA 20S CA, CT, XN, XH 25S XH, XN, CA, CT 25V CT, CA, XN, XH 25M CA, CT, SC 31S CA, MR 40S CA, CT, XN, XH 40V CA, CT, XN, XH 40M CA, CT, SC 23/24S CA, CT 23/24M CA 208 220 XH, XN XH, CA, CT ,XN XH, CA, CT, XN CA CA, CT, XN, XH CA RN5,CA CA CA, CT CA, CT CA5,RN5,RH CA CA CA, CT, SC CA CA CA, CT RN5,RH CA, CT CA, CT, SC CA CA, CT CA - 230 RN,RH RN,RH RN,RH RN,RH RN,RH - 240 XH, XN XH, CA, CT, MR, XN XH, CA, CT, MR, XN CA, CT CA, CT, XN, XH, MR CA, CT, RN, RH CA CA, CT, RN, RH RN, RH, CA, CT RH, RN, CA, CT CA, CT, SC CA, MR RH, RN, CA, CT CA, CT, XN, XH CA, CT, SC CA, CT CA 277 XH, XN XH, CA, XN, CT CA, XH, XN, CT XN, XH, CA XN, XH, CA CA, RN CA CA, CT CA, CT CA CA, SC CA CA, CT CA, CT CA, SC CA, CT CA 480 MR CA CT CA, MR CA, CT CA CA, CT CA, MR CA, CT CA, CT CA CA CT, CA CA, CT CA CA DT1 XH, XN XH, XN, CA, CT, MR CA, CT, XH, MR, XN CT XN, XH, CA, CT, MR CT, CA CA XN, XH, CA, CT XN, XH, MR CA, CT CA, CT, SC CA, CA, CT, XN, XH CA, CT, XN, XH CA, CT CA, CT CA DT2 XH, XN XH, XN, CA, CT, MR CA, CT, MR, XH, XN CT, CA XN, XH, CA, CT, MR CT, CA CA XN, XH, CA, CT XN, XH CA, CT CA, CT, SC CA CA, CT, XN, XH CA, CT, XN, XH CA, CT CA, CT CA DT3 MR CT MR CT CT CT CT CT - DT4 MR CT MR CT CT CT CT CT - Series 51 continued Watts 05S 07S 10S 10V 15S 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 23/24M MT1 XH, XN XH, XN, CA, CT CA, XN, XH, CT CA XN, XH, CA, CT CA CA CT, CA CA, CT CA CA, SC CA CA, CT CA CA, SC CA, CT CA MT2 XN, XH XH, XN, CA, CT CA, XN, XH, CT CA XN, XH, CA, CT CA CA CT, CA CA, CT CA CA, SC CA CA, CT CA CA, SC CA, CT CA MT7 XN, XH XH, XN, CA, CT CA, XN, XH, CT CA XN, XH, CA, CT CA CA CT, CA CA, CT CA CA, SC CA CA,CT CA CA, SC CA, CT CA MT8 XN, XH XH, XN, CA, CT CA, XN, XH, CT CA XN, XH, CA, CT CA CA CT, CA CA, CT CA CA, SC CA CA, CT CA CA, SC CA, CT CA TT1 XN, XH XN, XH XN, XH XN, XH CA CA CA CA CA CA - TT7 XN, XH XN, XH XN, XH XN, XH CA CA CA CA CA CA - TT3 XN, XH XN, XH XN, XH XN, XH CA CA CA CA CA CA - 347 XN, XH, CA, CT XN, XH XN, XH XN, XH, CA CA CA CA CA CA CA CA - See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 197 Floodlighting B A L L A S T M AT R I C E S Series 75 Watts 10S 10V 15S 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 23/24M 120 CA, CT, MR, RH, RN XH, XN, CA, CT RN, RH, CA, CT, MR XN, XH, CA, CT CA CA, CT, XN, XH ,MR XH, XN, CA, CT CT, CA, XN, XH CA, CT, SC CA, MR CA, CT, XN, XH CA, CT, XN, XH CA, CT, SC CA, CT CA 208 XH, CA, CT, XN CA CA, CT, XN, XH CA CA CA, CT CA, CT CA CA, CT, SC CA CA, CT CA, CT CA, CT, SC CA, CT CA 220 RN, CA CA, RN, RH CA CA RN, RH CA - 230 RN, RH RN, RH RN, RH RN, RH - 240 XH, CA, CT, MR, XN CA, CT CA, CT, XN, XH, MR CA, CT, RN, RH CA CA, CT, RN, RH, MR RN, RH, CA, CT RH, RN, CA, CT CA, CT, SC CA, MR RH, RN, CA, CT CA, CT, XN, XH CA, CT, SC CA, CT CA 277 480 CA, XH, XN, CT CA XN, XH, CA CT XN, XH, CA CA, MR CA, RN CA, CT CA CA CA, CT CA, CT, MR CA, CT CA CA CA, CT CA, SC CA, CT CA CA CA, CT CA CA, CT CT, CA CA, SC CA, CT CA, CT CA CA CA DT1 CA, CT, XH, MR, XN CT XN, XH, CA, CT, MR CT, CA CA XN, XH, CA, CT, MR XN, XH, MR CA, CT CA, CT, SC CA, CA, CT, XN, XH CA, CT, XN, XH CA, CT CA, CT CA DT2 CA, CT, MR, XH, XN CT, CA XN, XH, CA, CT, MR CT, CA CA XN, XH, CA, CT, MR XN, XH CA, CT CA, CT, SC CA CA, CT, XN, XH CA, CT, XN, XH CA, CT CA, CT CA Series 75 continued Watts 10S 10V 15S 17V 17M 20S 25S 25V 25M 31S 40S 40V 40M 23/24S 23/24M MT1 CA, XN, XH, CT CA XN, XH, CA, CT CA CA CT, CA CA, CT CA CA, SC CA CA, CT CA CA, SC CA MT2 CA, XN, XH, CT CA XN, XH, CA, CT CA CA CT, CA CA, CT CA CA, SC CA CA, CT CA CA, SC CA MT7 CA, XN, XH, CT CA XN, XH, CA, CT CA CA CT, CA CA, CT CA CA, SC CA CA, CT CA CA, SC CA, CT CA MT8 CA, XN, XH, CT CA XN, XH, CA, CT CA CA CT, CA CA, CT CA CA, SC CA CA, CT CA CA, SC CA, CT CA TT1 XN, XH XN, XH XN, XH CA CA CA CA CA CA CA, CT CA TT7 XN, XH XN, XH XN, XH CA CA CA CA CA CA CA, CT CA TT3 XN, XH XN, XH XN, XH CA CA CA CA CA CA - 347 XN, XH XN, XH XN, XH, CA CA CA CA CA CA CA CA - Series 77 Watts 40S 40V 40M 75S 75M 100S 100V 100M 120 CA, CT, XN, XH, MR CA, CT, XN, XH CA, CT, SC CA SC CA, CT CA CA, SC 208 CA, CT CA, CT CA, CT, SC CA SC CA, CT CA CS, SC 220 RN, RH CA CA 240 RH, RN, CA, CT, MR CA, CT, XN, XH CA, CT, SC CA SC CA, CT CA CA, SC 277 CA,CT CA, CT CA, SC XX SC CA, CT CA CA, SC 480 CA, MR CT, CA CA, CT, SC CA, CT CA CA, SC DT1 DT2 CA, CT, XN, XH, MR CA, CT, XN, XH, MR CA, CT, XN, XH CA, CT, XN, XH CA, CT CA, CT CA CA SC SC CA, CT CA,CT CA CA CA, SC CA, SC Series 77 continued Watts 40S 40V 40M 75S 75M 100S 100V 100M 198 MT7 CA, CT CA CA, SC SC CA CA CA, SC MT8 CA, CT CA CA, SC SC CA CA CA, SC Product Guide TT1 CA CA CA SC CA, SC TT7 CA CA CA SC CA, SC TT3 CA CA CA SC CA CA, SC 347 CA CA CA SC CA,SC For photometric information, please visit our website, www.americanelectriclighting.com DT3 MR CT CT - DT4 MR CT CT - MT1 CA, CT CA CA, SC SC CA CA CA, SC MT2 CA, CT CA CA, SC SC CA CA CA, SC DT3 CT MR CT MR CT CT CT CT - DT4 CT MR CT MR CT CT CT CT - DARK TO LIGHT TM ELECTRONIC PHOTOCONTROLS DE Series .................................................................200 DD Series.................................................................201 DPN Series ..............................................................202 DP Series .................................................................203 D Series....................................................................204 DX Series .................................................................205 DUX Series ..............................................................206 DBE Series...............................................................207 DB Series.................................................................208 DA Series.................................................................209 D779 Series..............................................................210 Shorting Caps..........................................................211 Photocontrol Accessories ....................................212 Photocontrol Recommendation Chart ................212 ANSI Color Chart ....................................................212 American Electric Lighting™ DE Series Filtered Silicon Electronic Twist Lock Photocontrol O R D E R I N G I N F O R M AT I O N Features: Filtered silicon light sensor. Human eye spectral response. Complies with ANSI C136.10-1996. MOV surge protection. Long life. Energy efficient. Four-year warranty. Available in job packs of J12 and J50 only. Silicon sensor with infrared blocking filter. Polypropylene cover, neoprene gasket, brass legs, acrylic window. Base rated for 120°C. Applications: Power consumption: 0.5 watts. Roadway and area lighting Areas with variable sky conditions Areas with high temperatures Load rating: 1000 watts, 1800 VA ballast. Sealed relay rated for 5000 operations at full load. Turn OFF light level is 1.5 times turn ON. 3.4 ounces each. -40°C to +70°C ambient, up to 90°C interface per ANSI. Dielectric strength: 5000 V per ANSI. Ordering Information DE240 DE347 DE480 Time Delay (seconds)1 Turn-on Level (ftc)1 Voltage DE120 DE124 Example: D E 1 2 0 - 1 . 5 - T J J 5 0 120 volts (105–130) 120/240/277 volts (105–305) 240 volts (185–305) 347 volts (300–400) 480 volts (420–530) 1.0 1.5 2.6 8.0 35 Energy saver ANSI standard IES recommendation Automile FAA T 2-5 second turn-off delay (standard) Surge Protector J 320 J/13,000 amp MOV Cover Color 1 Job Packs (blank) ANSI standard color* BK Black BR Brown P Upward facing J12 12 units J50 50 units * See chart page 212 DIMENSIONS 2-1/8" (52) 2-1/8" (52) Notes: 1 3-1/8" (76) 3-1/8" (76) Upward Facing 200 Product Guide For more information, visit our website, www.americanelectriclighting.com Other options available, please contact your local American Electric Lighting representative DD Series Diagnostics Electronic Twist Lock Photocontrol O R D E R I N G I N F O R M AT I O N Features: Regular dusk-to-dawn operation. Diagnostic feature detects and disables cycling HPS lamps and lamps that fail to start. Extends starting aids life. Flashing or steady LED alerts line crew of problem. Filtered silicon light sensor. 2-5 second off delay. MOV surge protection. Complies with ANSI C136.10-1996; not for use on incandescent fixtures. Four-year warranty. Available in job packs of J12 or J50 only. Applications: Polypropylene cover, neoprene gasket, brass legs, acrylic window base rated for 120°C. Roadway and area lighting High profile installations Anywhere cycling lamps are a problem Anywhere starting aid life is a problem Power consumption: 1.0 watts. Load rating: 70-400 watt HPS. Sealed relay rated for 5000 operations at full load. 3.8 ounces each. -40°C to +70°C ambient, up to 90°C interface per ANSI. Dielectric strength: 5000 V per ANSI. Ordering Information Example: D D 1 2 4 - 1 . 5 - T J A J 5 0 Voltage DD124 120/208/240/277 volts (105-305) 1.5 ANSI standard T 2-5 second turn-off delay (standard) Surge Protector J DIMENSIONS Cycle Detection1 Time Delay (seconds) Turn-on Level (ftc) 320J/13,000 amp MOV 2-1/8" (52) A B Job Packs After five lamp cycles, control turns lamp off. Next dusk, control turns lamp on and cycle detection circuit restarts. After five lamp cycles, control removes power from lamp until control is reset. Lamp remains off until power is removed from control for 30 seconds. J12 J50 12 units 50 units Notes: 1 3-1/8" (76) See pages 259-264 for a complete listing of Frequently Ordered Products Available with black cover only. Cycle Detection Program is set at factory; program cannot be altered in field Product Guide 201 DPN Series Part Night® Electronic Twist Lock Photocontrol O R D E R I N G I N F O R M AT I O N Features: Control turns on at dusk and off halfway through the night. Automatically self-adjusts to seasonal time changes, reducing maintenance. Reduces light pollution and light trespass concerns. Filtered silicon photocell provides long-term, drift-free light sensing. The infrared blocking polymer filter gives human eye response. A 2-5 second off-only time delay is provided to avoid turn-off from extraneous light. Complies with ANSI C136.10-1996. Four-year warranty. Energy Savings. Star FriendlyTM. Available in job packs of J12 or J50 only. Applications: Polypropylene cover, neoprene gasket, brass legs, acrylic window base rated for 120°C. Parking lots Area lights Park lights Media lighting Ball fields and courts Pedestrian lighting Power consumption: 0.8 watts. Load rating: 1000 watts, 1800 VA ballast. Sealed relay rated for 5000 operations at full load. Turn OFF is at middle of the night. 3.6 ounces each. -40°C to +70°C ambient, up to 90°C interface per ANSI. Dielectric strength: 5000 V per ANSI. Example: D P N 1 2 4 - 2 . 6 - T J G N J 5 0 Ordering Information Time Delay (seconds) Turn-on Level (ftc)1 Voltage DPN124 120/240/277 volts (105-305) DPN347 347 volts (300-400) 1.0 1.5 2.6 8.0 35 Energy saver ANSI standard Standard Automile FAA T Cover Color GN 2-5 second turn-off delay (standard) Surge Protector J Notes: DIMENSIONS 1 Other options available, please contact your local American Electric Lighting representative 2-1/8" (52) 3-1/8" (76) 202 Product Guide 320 J/13,000 amp MOV For more information, visit our website, www.americanelectriclighting.com Green (only) Job Packs J12 12 Units J50 50 Units DP Series Silicon Electronic Twist Lock Photocontrol O R D E R I N G I N F O R M AT I O N Features: Silicon light sensor. Complies with ANSI C136.10-1996. MOV surge protection. Long life. Energy efficient. Four-year warranty. Available in job packs of J12 or J50 only. Heat stabilized polymers are used in the base, enabling the control to withstand the high temperatures found on 400 and 1,000 watt HID floodlights and other fixtures. Inverse ratio (DPR) and fail off (DPF) options available. Applications: Inverse Ratio Controls are ideal for areas where it is important to turn on lights early but energy costs are a concern. Turn-off level is lower then turn-on levels. Model listed, PR124-1.5-TJ, is most commonly ordered. Various other models available. Contact your local American Electric Lighting representative for details and specifications. Roadway and area lighting Floodlights Areas with very high temperatures (DP Series High Temperature/Floodlight) Fail Off Controls are occasionally used for leased lighting. Model DPF124-1.5TJ is most commonly ordered. Various other models available. Contact your local American Electric Lighting representative for details and specifications. Ordering Information Example: D P 1 2 0 - 1 . 5 - T J B K J 5 0 Turn-on Level (ftc)1 Voltage DP120 DP124 120 volts (105–130) 120/240/277 volts (105–305) DP240 240 volts (185–305) DP347 347 volts (300–400) DP480 480 volts (420–530) DPR124 Multi-volt inverse ratio DPF124 Multi-volt fail off 1.0 1.5 2.6 8.0 35 Time Delay (seconds)1 T Energy saver ANSI standard IES recommendation Automile FAA 2-5 second turn-off delay Surge Protector J 320 J/13,000 amp (blank) ANSI standard color* MOV BK Black BR Brown P Upward facing * See chart page 212 Job Packs J12 12 units J50 50 units DIMENSIONS 2-1/8" (52) 2-1/8" (52) 3-1/8" (76) Cover Color 1 3-1/8" (76) Notes: 1 Other options available, please contact your local American Electric Lighting representative Upward Facing See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 203 D Series Classic Electronic Twist Lock Photocontrol O R D E R I N G I N F O R M AT I O N Features: Cadmium sulfide light sensor. Exceeds ANSI C136.10-1996. MOV surge protection. Long life. Energy efficient. Four-year warranty. Available in job packs of J12 or J50 only. Polypropylene cover, neoprene gasket, brass legs, acrylic window base rated for 120°C. Power consumption: 0.5 watts. Load rating: 1000 watts, 1800 VA ballast. Applications: Sealed relay rated for 5000 operations at full load. Roadway and area lighting Turn OFF light level is 1.5 times turn ON. 3.4 ounces each. -40°C to +70°C ambient, up to 90°C interface per ANSI. Dielectric strength: 5000 V per ANSI. Ordering Information Example: D 1 2 4 - 1 . 5 - S T J J 5 0 Voltage D120 D124 D240 120 volts (105–130) 120/240/277 volts (105–305) 240 volts (185–305) 1.0 1.5 2.6 Energy saver ANSI standard IES recommendation T 2-5 second turn-off delay Surge Protector Light Sensor S Cover Color 1 Time Delay (seconds)1 Turn-on Level (ftc)1 Standard cadmium sulfide J (blank) BK BR P ANSI standard color* Black Brown Upward facing * See chart page 212 Notes: 1 2-1/8" (52) 1-1/2" (37) 3-1/8" (76) Upward Facing 204 Product Guide J12 12 units J50 50 units 320 J/13,000 amp MOV DIMENSIONS 2-7/8" (70) Job Packs For more information, visit our website, www.americanelectriclighting.com Other options available, please contact your local American Electric Lighting representative DX Series Basic Electronic Twist Lock Photocontrol O R D E R I N G I N F O R M AT I O N Features: Silicon light sensor. Complies with ANSI C136.10-1996. MOV surge protection. Long life. Energy efficient. Economical. Three-year warranty. Available in job packs of J12 or J50 only. Standard 160 joule, 6500 amp MOV rated for multiple surges. Polypropylene cover, Neoprene gasket, brass legs, acrylic window base rated for 120°C. Applications: Power consumption: 0.5 watts. Roadway and area lighting Security lighting Municipal lighting Load rating: 1000 watts, 1800 VA ballast. Sealed relay rated for 5000 operations at full load. 3.4 ounces each. -40°C to +70°C ambient, up to 90°C interface per ANSI. Dielectric strength: 5000 V per ANSI. Example: D X 1 2 4 - 1 2 A J 5 0 Ordering Information Voltage DX120 DX124 DX347 DX480 Sensor Turn-on Level (ftc) 120 volts (105–130) 120/240/277 volts (105–305) 347 volts (300–400) 480 volts (420–530) 1 1.2–3 ftc turn-on (standard) 2 Silicon sensor, time delay (2-5 seconds) A P Cover Color Job Packs ANSI standard* Upward facing J12 12 units J50 50 units * See chart page 212 DIMENSIONS 2-1/8" (52) 1-1/2" (37) 2-7/8" (70) 3-1/8" (76) Upward Facing See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 205 DUX Series Basic Twist Lock Photocontrol O R D E R I N G I N F O R M AT I O N Features: Silicon light sensor. Complies with ANSI C136.10-1996. MOV surge protection. Long life. Energy efficient. Economical. Three-year warranty. Available in job packs of J12 or J50 only. Standard 160 joule, 6500 amp MOV rated for multiple surges. Polypropylene cover, Neoprene gasket, brass legs, acrylic window base rated for 120°C. Applications: Area lighting Security lighting Yard lighting Power consumption: 0.5 watts. Load rating: 1000 watts, 1800 VA ballast. Sealed relay rated for 5000 operations at full load. 3.4 ounces each. -40°C to +70°C ambient, up to 90°C interface per ANSI. Dielectric strength: 5000 V per ANSI. UL listed. Example: D U 1 2 0 - 1 2 A J 5 0 Ordering Information Voltage DUX120 120 volts (105–130) DUX124 120/240/277 volts (105–305) DUX347 347 volts (300–400) DUX480 480 volts (420–530) 1 2 1.2–3 ftc turn-on (standard) Silicon sensor, time delay (2-5 seconds) 2-1/8" (52) 1-1/2" (37) 3-1/8" (76) Upward Facing 206 Product Guide A P ANSI standard* Upward facing * See chart page 212 DIMENSIONS 2-7/8" (70) Cover Color Sensor Turn-on Level (ftc) For more information, visit our website, www.americanelectriclighting.com Job Packs J12 12 units J50 50 units DBE Series Button Electronic Wire-In Photocontrol O R D E R I N G I N F O R M AT I O N Features: Electronic wire-in button photocontrol. Instant turn-on, standard 5-10 second turn-off time delay. Filtered Silicon light sensor. UL Listed models available. Filtered silicon light sensor. Voltages 120–347. Complies with ANSI C136.24. Long life. Low maintenance. Four-year warranty. Applications: Available in job packs of J12 or J25 only. Park lighting Security lighting Post lanterns Decorative and area lighting Example: D B E 1 2 0 1 . 5 - T J 2 5 Ordering Information Voltage DBE120 DBE240 DBE347 Time Delay (seconds) Turn-on Level (ftc) 120 volts (105–130) 208/240/277 volts (200–305) 347 volts (300–400) 1.5 ANSI standard T 5-10 second turnoff delay (standard) Job Pack J12 J25 12 units 25 units DIMENSIONS 3/8” (18) Straight pipe thread 0.80" (20) (Width) 1.30" (32) (Height) 1.25" (31) 2.25" (55) (Length) See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 207 DB Series Button Electronic Wire-In Photocontrol O R D E R I N G I N F O R M AT I O N Features: Electronic, utility-grade wire-in button photocontrol. Instant turn-on, standard 5-10 second turn-off time delay. Cds cell. UL Listed models available. Voltages 120–347. Complies with ANSI C136.24. Long life. Low maintenance. Four-year warranty. Available in job packs of J12 or J25 only. Applications: Park lighting Security lighting Post lanterns Decorative and area lighting Ordering Information Example: D B 1 2 0 - 1 . 5 - S T J 2 5 Turn-on Level (ftc) Voltage DB120 DB240 DB347 120 volts (105–130) 208/240/277 volts (200–305) 347 volts (300–400) 1.5 ANSI standard S Light Sensor Standard cadmium T sulfide Time Delay Certification1 Job Packs 5-10 second turn-off (blank) No listing J12 12 units delay (standard) A12 UL listed J25 25 units 25UA with 12” leads 1/2” stripped. DIMENSIONS 3/8” (18) Straight pipe thread 0.80" (20) (Width) 1.30" (32) Notes: (Height) 1.25" (31) 1 2.25" (55) (Length) 208 Product Guide For more information, please visit our website, www.americanelectriclighting.com Other options available, please contact your local American Electric Lighting representative DA Series Button Wire-In Photocontrol O R D E R I N G I N F O R M AT I O N Features: Wire-in mechanical button photocontrol. Instant turn-on, 30-60 second turn-off time delay. UL Listed models available. Sealed cds cell. Voltages 120 and 208/240/277. Load rating UL773A: 600VA ballast, ANSI: 1000 VA ballast. Available in job packs of J12 or J25 only. Complies with ANSI C136.24. Low maintenance. One-year warranty. Applications: Park lighting Security lighting Post lanterns Decorative and area lighting Wall packs Ordering Information Example: D A 1 2 0 - 1 2 A J 2 5 Voltage DA120 DA240 Time Delay (seconds) Turn-on Level (ftc) 1 120 volts (105–130) 208/240/277 volts (200–305) ANSI standard 2A 30-60 second turnoff delay (standard) Job Pack J12 J25 12 units 25 u1nits DIMENSIONS 3/8” (18) Straight pipe thread 15” Leads, 18 AWG, 105-degrees C (Width) 1.1" (28) 1.0" (25) (Height) .95" (22) 2.0" (50.0) (Length) See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 209 D779 Series Electronic Locking-Type Photocontrol O R D E R I N G I N F O R M AT I O N Features: Silicon light sensor. Complies with ANSI C136.10-1996. Two-year warranty. Standard 190 joule, 4500 amp MOV. Polypropylene cover, neoprene gasket, brass legs, acrylic window base rated for 120°C Power consumption: 0.5 watts. At 120 VAC Load rating: 1000 watts, 1800 VA ballast . Sealed relay rated for 5000 operations at full load. Instant turn on, 2-5 second turn off. Turn on is 1.5 + 0.5 ftc, turn off is 1.5 times turn on. 3.4 ounces each. Available in job packs of J25 or J50 only. -40°C to +70°C ambient, up to 90°C interface per ANSI. Dielectric strength: 5000 V per ANSI. D7790 is a replacement for many industry standard type locking photocontrols. Ordering Information Example: D 7 7 9 0 J 5 0 Job Pack Voltage D7790 120/208/240/277 VAC D7793 347 VAC D7794 480 VAC J12 J25 12 Units 25 Units DIMENSIONS 2-1/8" (52) 3-1/8" (76) 210 Product Guide For more information, please visit our website, www.americanelectriclighting.com Shorting Caps Twist Lock Type O R D E R I N G I N F O R M AT I O N SHORTING AND OPEN CAPS For luminaires where lights are to be on continuously (shorting cap) or left off (open cap). Exceeds ANSI C136.10-1996. Description Catalog Number Shorting cap. Black cover. D-SHORT-SBK Shorting cap 320J. MOV surge protection. Black cover. D-SHORT-VBK Open cap. Red cover. D-OPEN-SRD DIMENSIONS 3.10" (79) 2.95" (75) 1.12" (28) .56" (14) See pages 259-264 for a complete listing of Frequently Ordered Products Product Guide 211 Photocontrol Accessories OA RC DC E RS IS NO GR I IENS F O R M A T I O N Catalog Number Description PHOTOCONTROL RECEPTACLES Mounting adapter for connecting photocontrol to net. For pole, wall and frame mounting. 14” x 14” gage wire. Line = black, Load = red, Neutral = white. Each receptacle meets NEMA and ANSI standards. DUR-103 With bracket and rotating cup with locknut. PHOTOCONTROL TEST CAP Lightweight black vinyl cap tests the working operation of photocontrols during daylight hours. Completely eliminates direct and reflected light, enabling quick and easy testing. Not designed for use with hot sticks. Affordably priced. D-TEST CAP 1 - 1/2" (37) 3 - 1/4" (79) PHOTOCONTROL DEMO BOX Portable 120-volt test box. Dimensions: 51/2 x 3 x 21/2 inches. D-DEMO BOX Color Chart Photocontrol Recommendation Chart DTL SERIES Type Voltages Available Light Sensor Surge Protection Application Typical Electronic D Locking 120-277 MOV, 320 Joule Roadway Yes DP Locking 120-480 Cadmium Sulphide Silicon MOV, 320 Joule Roadway Yes DE Locking 120-480 DX Locking DUX DU Locking, UL Listed Locking, Part Night Locking, Diagnostic Locking DB Button 120 and 208-277 DBE Button 120 and 208-277 DA Button 120 and 208-277 D7790 Locking DPF Locking, Fail OFF Locking, Inverse Ratio Locking, Reverse DPN DD DPR DPO 212 Product Guide MOV, 320 Joule Roadway Yes 120-480 Filtered Silicon Silicon MOV, 320 Joule C&I + Roadway Yes 120-480 Silicon MOV, 320 Joule Yes 120-277 Silicon MOV, 160 Joule Where UL is needed Off-Roadway 120-277 Silicon MOV, 160 Joule Roadway Yes 120 and 208-277 none C&I or OEM No MOV, 190 Joule Post top fixtures Yes MOV, 190 Joule Utility post top Yes none C&I or OEM No 120-347 Cadmium Sulphide Cadmium Sulphide Filtered Silicon Cadmium Sulphide Silicon 120-277 Yes MOV, 190 Joule Roadway or export Yes Silicon MOV, 320 Joule Off-Roadway Yes 120-277 Silicon MOV, 320 Joule Roadway Yes 120-277 Silicon MOV, 320 Joule OFF night, ON day Yes For more information, please visit our website, www.americanelectriclighting.com ANSI Color Codes 120V 240V Multi-volt 350V 480V Gray Maroon Dark Blue Green Yellow POLES Illustrated Samples ................................................214 RSA ...........................................................................218 Wind Map ................................................................215 RTA............................................................................219 Florida Wind Rating................................................216 RSAH ........................................................................220 General Information...............................................217 SSA ...........................................................................221 SSAH ........................................................................222 RSS ...........................................................................223 RTS............................................................................224 SSS ...........................................................................225 STS............................................................................226 STSH.........................................................................227 Pole Options ............................................................228 Aluminum Mounting Brackets .............................229 Steel Mounting Brackets ......................................230 RTF ............................................................................231 RTFDB.......................................................................232 SSF............................................................................233 RTCD.........................................................................234 RTCDDB ...................................................................235 STC............................................................................236 SPRTC.......................................................................237 SPRTS.......................................................................241 RTAU.........................................................................244 RTSU.........................................................................248 AMAW / SMAW......................................................250 AMAC / SMAC ........................................................252 SMAWL ....................................................................254 Options & Accessories..........................................256 American Electric Lighting™ I L L U S T R AT E D S A M P L E S There are several different pole types available throughout this section. Below are a few samples. Please contact your local American Electric Lighting representative for more information. Round Straight Aluminum Round Straight Steel 18” 18” Round Tapered Aluminum Square Straight Steel Square Straight Aluminum 18” 18” Square Tapered Steel 18” 214 Product Guide Round Tapered Fiberglass For more information, please visit our website, www.americanelectriclighting.com Square Tapered Steel Hinge Contact AEL for specific data. W I N D M A P Product Guide 215 F L O R I D A P O L E W I N D R AT I N G SIDE-MOUNTED LOAD Max WT/EPA Max WT/EPA 130mph Zone 150mph Zone 14.2 / 100 10.3 / 100 11.2 / 200 7.9 / 200 13.4 / 200 9.6 / 200 10.3 / 225 7.1 / 225 19.7 / 225 14.2 / 225 9.6 / 225 5.7 / 225 13.4 / 225 9.2 / 225 TENON-MOUNTED LOAD Max WT/EPA Max WT/EPA 130mph Zone 150mph Zone 13.0 / 100 9.4 / 100 10.4 / 200 7.3 / 200 12.5 / 200 8.9 / 200 9.7 / 225 6.7 / 225 18.6 / 225 13.4 / 225 9.1 / 225 5.4 / 225 12.9 / 225 8.8 / 225 RTS 20 25 25 30 30 35 39 6-5B 7-0B 7-0F 8-0B 8-0F 9-5B 9-0F Max. Wt. that will be used 100 200 200 225 225 225 225 SSS 20 25 30 5G 5G 6G 100 100 100 DS330500W200 DS330500W250 DS330600W300 11.8 / 100 6.3 / 100 5.7 / 100 7.5 / 100 3.1 / 100 1.8 / 100 10.9 / 100 6.0 / 100 5.4 / 100 6.9 / 100 2.9 / 100 1.7 / 100 SSA 20 25 6G 6J 100 100 2000-60606N4 2000-60608N4 5.8 3.5 2.4 0 0 0 0 0 RTA 20 25 30 30 35 7E 8G 8G 10G 10G 100 200 200 225 225 1908-40705T4 2408-45806T4 2908-45806T4 2908-60106T4 3408-60106T4 7.5 8.8 5.6 11.4 8 5.3 6.2 3.6 7.7 5 7.2 8.5 5.5 11.2 7.9 5.1 6 3.7 7.6 4.9 Steel Valmont No. C H A R T DS210650A200 DS210700A250 DS210700E250 DS210800A300 DS210800E300 DS210950A350 DS210900E389 Aluminum 1. Values are fastest-mile speeds at 33ft. (10m) above ground. 2. Linear interpolation between wind speed contours is acceptable. 3. Special wind regions require caution in application of wind speed information. Contact your American Electric Lighting representative for specific data. 216 Product Guide For more information, please visit our website, www.americanelectriclighting.com Poles General Information Poles are available only in US O R D E R I N G I N F O R M AT I O N Example: S S A 1 6 4 G D M 1 9 D D B A E L Shaft Type RTA RSA RSAH SSA SSAH RTS STS STSH RSS SSS SSF RTF RTFDB SPRTC STC SPRTS Nominal Shaft Base Size/Wall Thickness (in.) Fixture Mounting Method Round tapered aluminum Round straight aluminum 4 C 0.125 Round straight aluminum hinged 5 E 0.156 Square straight aluminum 6 G 0.188 Square straight aluminum hinged 7 J 0.250 Round tapered steel 8 K 0.312 Square tapered steel 9 L 0.219 Square tapered steel hinged 10 P 0.375 Round straight steel Square straight steel Square straight fiberglass Round tapered fiberglass Nominal mounting height Round tapered fiberglass direct burial 8–50 feet Sportslighting poles Round tapered concrete up to 115'. sportslighting See website for specific Square tapered concrete information. Round tapered steel Option See pages Only open-top pole 256-257 accepts KKS (4" square) and KKR (4-1/2" round) luminaires Tenon Mounting T20 2-3/8" O.D. (2" NPS) T25 2-7/8" O.D. (2-1/2" NPS) T30 3-1/2" O.D. (3" NPS) T35 4" O.D. (3-1/2" NPS) Drill Mounting DM19 1 at 90° DM28 2 at 180° DM29 2 at 90° DM39 3 at 90° DM49 4 at 90° DM32 3 at 120° (Round Poles) PT Finish Architectural Colors1 Polyester Powder Standard Colors DDB Dark bronze DWH White DBL Black BA Brushed aluminum2 Class 1 Architectural Anodize (RTA, RSA, SSA only) ABL Black ADB Dark bronze ANA Natural sportslighting Notes: 1 Other colors available; please contact your local American Electric Lighting representative 2 Aluminum poles only Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option. All luminaire/pole assemblies require proper evaluation to ensure that the structural integrity of the assembly is not compromised when applied in specific wind conditions. Therefore, the basis for pole selection in this catalog is total weight and effective projected area, EPA (ft2), shown on the individual pole catalog pages. Determination of maximum EPA (ft2) and weight loading must include all luminaires, bracketry, signs, decoration, overhead wire or other equipment that will be mounted to the subject pole. Luminaire EPA (ft2) and weight data are found on their respective product pages. The total effective projected area of the luminaires and brackets shall not exceed the EPA (ft2) listed for the pole selected at a given wind velocity. Poles that are to be located in areas of known abnormal conditions will require special consideration. The map on page 215 gives the wind velocities to be used in determining luminaire pole compatibility. Note: If during the pole warranty period of one year, the product proves defective in material or workmanship, the company shall correct, at its option, by repairing or replacing at no charge to the purchaser, if the purchaser promptly notifies the company. This warranty specifically excludes fatigue failure or similar phenomena resulting from induced vibration harmonic oscillation or resonance associated with the movement of air currents around the product. Pole Selection Procedure Step 1. Select the luminaire and decide how many will be mounted per pole. Determine the Effective Projected Area, EPA (ft2), which is given on the dimensional information table. Step 2. Determine the appropriate mounting method for the luminaire. Options include arm, bracket or wall mounting. Step 3. Add together the EPA's (ft2) of the luminaire and arm/bracket. Multiply by number of fixtures to be mounted on one pole. Step 4. Consult the Wind Map on page 215 to determine the basic wind velocity for your area. Step 5. Select the material (steel or aluminum) and shape (square or round) of the pole. Refer to the “Technical Information” chart on the appropriate pole page. A. Find the desired nominal mounting height in the second column. B. Verify that the fixture weight does not exceed the maximum number listed. C. Compare your total EPA (ft2) loading with the maximum EPA (ft2) value found in the wind speed column for your area. Check that the equipment you are using will not exceed this value. D. If both the weight and EPA (ft2) values do not exceed for which the pole is rated, you have selected the correct pole. If, however, either one of those numbers exceeds the maximum rated values, compare the EPA (ft2) and fixture weight loads to the next larger pole of the same mounting height. CAUTION: This pole selection process is a guideline only. American Electric Lighting assumes no responsibility for selection and recommends consultation with qualified individuals for verification of luminaire/pole assembly selection. Pole Data (RSA) Shaft Base Size Bolt Circle A Bolt Projection B Base Square C Anchor Bolt Description Warehouse Anchor Bolt Description Template Number 4" 4-1/2" 5" 6" 6-1/2"-8-1/4" 7-1/8"-8-3/8" 7-1/2"-9-1/2" 8-3/4"-10-1/4" 3-1/4" 3-1/4" 3-1/4" 3-1/2" 8-3/4" 8-1/2" 9-1/4" 10-1/4" ABRSA-4 ABRSA-4-5 ABRSA-5 ABRSA-6 AB18-0 AB18-0 AB18-0 AB30-0 PJ50057 PJ50040 PJ50058 PJ50059 Product Guide 217 RSA Anchor Base Poles Round Straight Aluminum P R O D U C T O V E R V I E W Intended Use For 4-1/2” O.D., 8’ to 25’ mounting height. Grounding – Ground lug located immediately inside handhole is tapped for C|, -16 UNC ground bolt (not supplied). Features: Shaft – One-piece extruded 6063-T6 aluminum alloy with T6 temper. Circumferential satin-brushed finish. 4-1/2" round straight tube is uniform in cross-section down length of shaft. Anchor Base – Cast from A356 aluminum alloy and heat treated to T6 temper. Base slipfits shaft, and they are joined together by continuous circumferential welds at both top and bottom of anchor base to provide maximum strength at area of critical stress. Anchor Bolts – Top 12" is galvanized per ASTM A-153. Made of carbon steel bar with a minimum-yield strength of 55,000 psi. Handhole – Reinforced 3"x5" handhole is located 18" above base. Cover and attachment hardware furnished. Hardware – Stainless steel. Top Cap – Cast-aluminum cap is provided for drill-mount poles. Finish – Standard finish is brushed aluminum. Optional polyester powder paint and anodized finishes available. Bolt Covers – A356 nut covers included with anchor base unless otherwise specified. Ordering Information: See page 217 (Note: Poles are available only in U.S.) INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factorysupplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. 218 Product Guide Technical Information EPA (ft2) with 1.3 gust Catalog Number RSA 8 4C RSA 8 4-5C RSA 8 4-5G RSA 10 4C RSA 10 4-5C RSA 10 4-5G RSA 10 5C RSA 12 4C RSA 12 4-5C RSA 12 4-5G RSA 12 5C RSA 12 5E RSA 12 5G RSA 14 4C RSA 14 4-5C RSA 14 4-5G RSA 14 5C RSA 14 5E RSA 14 5G RSA 16 4C RSA 16 4-5C RSA 16 4-5G RSA 16 5C RSA 16 5E RSA 16 5G RSA 16 6E RSA 16 6G RSA 18 4-5G RSA 18 5C RSA 18 5E RSA 18 5G RSA 18 6G RSA 20 4-5G RSA 20 5C RSA 20 5E RSA 20 5G RSA 20 6E RSA 20 6G RSA 25 4-5G RSA 25 6E RSA 25 6G RSA 30 6G Nom. Pole Wall Mount. Shaft Size Thick. Ht. (ft.) (in. x in. x ft.) (in.) 8 8 8 10 10 10 10 12 12 12 12 12 12 14 14 14 14 14 14 16 16 16 16 16 16 16 16 18 18 18 18 18 20 20 20 20 20 20 25 25 25 30 4.0 x 8.0 4.5 x 8.0 4.5 x 8.0 4.0 x 10.0 4.5 x 10.0 4.5 x 10.0 5.0 x 10.0 4.0 x 12.0 4.5 x 12.0 4.5 x 12.0 5.0 x 12.0 5.0 x 12.0 5.0 x 12.0 4.0 x 14.0 4.5 x 14.0 4.5 x 14.0 5.0 x 14.0 5.0 x 14.0 5.0 x 14.0 4.0 x 16.0 4.5 x 16.0 4.5 x 16.0 5.0 x 16.0 5.0 x 16.0 5.0 x 16.0 6.0 x 16.0 6.0 x 16.0 4.5 x 18.0 5.0 x 18.0 5.0 x 18.0 5.0 x 18.0 6.0 x 18.0 4.5 x 20.0 5.0 x 20.0 5.0 x 20.0 5.0 x 20.0 6.0 x 20.0 6.0 x 20.0 4.5 x 25.0 6.0 x 25.0 6.0 x 25.0 6.0 x 30.0 0.125 0.125 0.188 0.125 0.125 0.188 0.125 0.125 0.125 0.188 0.125 0.156 0.188 0.125 0.125 0.188 0.125 0.156 0.188 0.125 0.125 0.188 0.125 0.156 0.188 0.156 0.188 0.188 0.125 0.156 0.188 0.188 0.188 0.125 0.156 0.188 0.156 0.188 0.188 0.156 0.188 0.188 80 mph 90 mph 100 mph Max. Wt. Bolt Circle (in.) 11.2 14.6 21.8 8.2 10.6 16.3 13.6 6.0 8.1 12.7 10.3 13.2 16.2 4.1 5.8 9.7 7.8 10.3 12.8 2.8 4.2 7.5 5.9 8.0 10.1 13.6 16.8 5.7 4.3 6.1 8.0 13.9 4.3 3.0 4.7 6.4 9.3 11.8 1.3 5.2 7.1 3.5 8.6 11.3 17.0 6.1 8.1 12.6 10.6 4.3 6.0 9.7 8.0 10.3 12.6 2.8 4.2 7.3 6.0 8.0 9.9 1.6 2.8 5.5 4.4 6.1 7.8 10.6 13.0 4.0 3.1 4.6 6.8 10.7 2.9 2.1 3.4 4.8 7.1 9.1 — 3.8 5.3 2.4 6.8 9.1 13.7 4.7 6.5 10.1 8.5 3.2 4.8 7.7 6.3 8.2 10.1 1.9 3.3 5.8 4.7 6.3 7.9 1.0 2.1 4.3 3.4 4.8 6.1 8.4 10.4 3.1 2.4 3.5 4.7 8.5 2.1 1.5 2.6 3.6 5.5 7.1 — 2.8 4.0 1.6 125 175 225 100 133 175 150 110 80 185 150 200 225 75 60 190 100 125 150 150 50 155 175 190 200 225 245 123 150 175 225 225 95 150 150 150 175 200 100 150 150 200 6-1/2-8-1/4 7-1/8-8-3/8 7-1/8-8-3/8 6-1/2-8-1/4 7-1/8-8-3/8 7-1/8-8-3/8 7-1/2-9-1/2 6-1/2-8-1/4 7-1/8-8-3/8 7-1/8-8-3/8 7-1/2-9-1/2 7-1/2-9-1/2 7-1/2-9-1/2 6-1/2-8-1/4 7-1/8-8-3/8 7-1/8-8-3/8 7-1/2-9-1/2 7-1/2-9-1/2 7-1/2-9-1/2 6-1/2-8-1/2 7-1/8-8-3/8 7-1/8-8-3/8 7-1/2-9-1/2 7-1/2-9-1/2 7-1/2-9-1/2 8-3/4-10-1/4 8-3/4-10-1/4 7-1/8-8-3/8 7-1/2-9-1/2 7-1/2-9-1/2 7-1/2-9-1/2 8-3/4-10-1/4 7-1/8-8-3/8 7-1/2-9-1/2 7-1/2-9-1/2 7-1/2-9-1/2 8-3/4-10-1/4 8-3/4-10-1/4 7-1/8-8-3/8 8-3/4-10-1/4 8-3/4-10-1/4 8-3/4-10-1/4 For more information, please visit our website, www.americanelectriclighting.com Bolt Approx. Size Ship Wt. (in. x in. x in.) (lbs.) 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 30 x 3 22 30 38 26 34 43 36 30 38 50 36 44 53 35 42 56 39 47 56 38 46 62 46 53 60 53 78 68 48 58 68 86 74 54 68 82 95 110 89 108 128 146 RTA Anchor Based Poles Round Tapered Aluminum P R O D U C T O V E R V I E W Intended Use For 20’ to 40’ mounting height. Grounding – A ground lug located immediately inside the handhole is tapped round bolt (by others). Features Shaft – The shaft is spun tapered from seamless 6063 alloy aluminum tubing and is heat treated to produce a T6 temper. The shaft is cone tapered to the butt diameter. Handhole – A nominal 3"x5" or 4"x6" reinforced flushed covered handhole is centered 18" above the base. Hardware – All screws, nuts and bolts are made of stainless steel. Anchor Base – Cast from A356 alloy aluminum, the anchor base is heat treated to a T6 condition. The anchor base telescopes the pole shaft and is circumferentially welded top and bottom. Top Cap – Cast-aluminum cap is provided for drill mount poles. Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of steel rod having a minimum yield strength of 55,000 PSI. Bolt Covers – A356 nut covers shall be included with each anchor base unless otherwise specified. Finish – Standard finish is brushed aluminum. Optional polyester powder paint and anodized finishes available. Ordering Information: See page 217 (Note: Poles are available only in U.S.) Technical Information EPA (ft2) with 1.3 gust Catalog Number RTA 20 5C RTA 20 5G RTA 20 6G RTA 20 7E RTA 25 6E RTA 25 7E RTA 25 8E RTA 25 8G RTA 30 7E RTA 30 8E RTA 30 8G RTA 30 10G RTA 35 8E RTA 35 8G RTA 35 8J RTA 35 10G RTA 39 8G RTA 39 8J RTA 39 10G RTA 39 10J Nom. Pole Wall Mount Shaft Size Thickness 80 Ht. (ft.) (in. x in. x ft.) (in.) mph 20 20 20 20 25 25 25 25 30 30 30 30 35 35 35 35 39 39 39 39 5 x 3 x 19’8” 5 x 3 x 19’8” 6 x 4 x 19’8” 7 x 4 x 19’8” 6 x 4 x 24’ 8” 7 x 4 x 24’8” 8 x 4.5 x 24’ 8” 8 x 4.5 x 24’ 8” 7 x 4 x 29’8” 8 x 4.5 x 29’8” 8 x 4.5 x 29’8” 10 x 6 x 29’8” 8 x 4.5 x 34’8” 8 x 4.5 x 34’8” 8 x 4.5 x 34’8” 10 x 6 x 34’8” 8 x 4.5 x 38’8” 8 x 4.5 x 38’8” 10 x 6 x 38’8” 10 x 6 x 38’8” 0.125 0.188 0.188 0.156 0.156 0.156 0.156 0.188 0.156 0.156 0.188 0.188 0.156 0.188 0.250 0.188 0.188 0.250 0.188 0.250 3.9 7.4 12.2 15.0 5.3 9.5 14.2 18.0 5.5 9.4 12.4 23.8 5.8 8.3 12.9 17.9 5.6 9.7 14.2 20.4 90 mph 100 mph Max. wt. 2.5 5.2 9.2 11.4 3.6 7.0 10.9 13.8 3.8 7.0 9.4 18.3 4.1 6.0 9.7 13.6 3.9 7.1 10.5 15.5 1.6 3.8 7.2 9.0 2.6 5.4 8.5 10.9 2.7 5.3 7.3 14.3 2.9 4.5 7.5 10.4 2.7 5.4 7.8 11.9 100 100 214 256 114 162 220 261 111 151 179 377 119 141 183 295 122 158 253 300 Approx. Bolt Circle Bolt Size Ship Wt. (in.) (in. x in. x in.) (lbs.) 7-1/2-9-1/2 7-1/2-9-1/2 9–10 9-7/8-11-1/4 9–10 9-7/8-11-1/4 11–12 11–12 9-7/8-11-1/4 11–12 11–12 14-1/4-16-1/4 11–12 11–12 11–12 14-1/4-16-1/4 11–12 11–12 14-1/4-16-1/4 14-1/2-16 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 30 x 3 1 x 36 x 4 3/4 x 30 x 3 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 40 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 40 x 4 1 x 36 x 4 1 x 36 x 4 1 x 40 x 4 1-1/4 x 48 x 5 62 72 107 103 106 120 130 153 135 150 175 235 185 220 251 268 250 280 295 373 INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. Notes: 1 2 3 4 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° Options: See page 256-257 Brackets: See page 228-229 Pole Data Shaft Base Size Bolt Circle A Bolt Projection B Base Square C Anchor Bolt Description Warehouse Anchor Bolt Description Template Number 5" 6" 7" 8" 10"G 10"J 7-1/2"–9-1/2" 9"–10" 9-7/8"–11-1/4" 11"-12" 14-1/4"–16-1/4" 14-1/2"–16" 3-1/4" 3-1/2" 4-1/8" 4-1/4" 4-1/2" 5" 9-1/4" 10" 10-1/2" 11-1/2" 14-1/2" 14-1/2" ABRTA-5 ABRTA-6 ABRTA-7 ABRTA-8 ABRTA-10G ABRTA-10J AB18-0 AB30-0 AB36-0 AB36-0 N/A N/A PJ50032 PJ50033 PJ50034 PJ50035 PJ50036 PJ50063z 18” (45.7cm) Product Guide 219 RSAH Anchor Base Poles Round Straight Aluminum, Hinged P R O D U C T O V E R V I E W Intended Use For 10’ to 20’ mounting height. steel hex head bolts which attach to stainless steel inserts cast into the aluminum base. A cast-aluminum two-piece cover is included. Features Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of carbon steel bar having a minimum-yield strength of 55,000 PSI. Shaft – One-piece extruded 6063 aluminum alloy with a T6 temper. Circumferential satin-brushed finish. The round, straight tube is uniform in cross-section down the length of the shaft. Handhole – Available as an option, and located 90o to the right of the hinge. Hinged Anchor Base – Cast from A356 aluminum alloy, the anchor base is heat treated to a T6 temper. The shaft inserts into the tilting section of the hinged base and is joined together by continuous circumferential welds at the outside top and inside bottom. The tilting and anchored sections of the hinged base are joined by a 3/4" diameter solid aluminum pivot rod. The tilting section of the hinged base is held in a vertical position by three 1/2"-13 x 2 1/2" stainless Hardware – Stainless steel. Top Cap – Cast-aluminum cap is provided for drill mount poles. Finish – Standard finish is brushed aluminum. Optional polyester powder painted and anodized finishes available. Ordering Information: See page 217 (Note: Poles are available only in U.S.) Technical Information EPA (ft2) with 1.3 gust INSTALLATION NOTES: Catalog Number Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. RSAH 10 4C RSAH 14 4C RSAH 14 5E RSAH 16 4C RSAH 16 5C RSAH 16 6E RSAH 18 5C RSAH 18 5G RSAH 20 5C RSAH 20 5G RSAH 20 6G Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. Nom. Pole Wall Mount. Shaft Size Thick. Ht. (ft.) (in. x in. x ft.) (in.) 10 14 14 16 16 16 18 18 20 20 20 4 x 4 x 10 4 x 4 x 14 5 x 5 x 14 4 x 4 x 16 5 x 5 x 16 6 x 6 x 16 5 x 5 x 18 5 x 5 x 18 5 x 5 x 20 5 x 5 x 20 6 x 6 x 20 0.125 0.125 0.156 0.125 0.125 0.156 0.125 0.188 0.125 0.188 0.188 80 mph 90 mph 100 mph Max. Wt. Bolt Circle (in.) 8.2 4.4 10.6 3.1 6.2 13.8 4.5 8.2 3.2 6.4 11.7 6.1 3.0 8.2 1.9 4.7 10.7 3.3 6.2 2.2 4.8 9.0 4.7 2.1 6.5 1.2 3.6 8.5 2.5 4.9 1.6 3.7 7.1 100 100 100 100 100 100 130 130 130 130 130 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 Bolt Approx. Size Ship Wt. (in. x in. x in.) (lbs) 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 30 x 3 43 50 66 54 60 88 65 90 69 97 110 C Notes: A 1 2 3 4 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° Options: See page 256-257 Brackets: See page 228-229 Pole Data Tapped 3/8” - 16 for ground connector Two-piece cast-aluminum cover 220 Product Guide Shaft Base Size Bolt Circle A Bolt Projection B Base Square C Anchor Bolt Description Warehouse Anchor Bolt Description Template Number 4" 5" 6" 8-1/2"–10" 8-1/2"–10" 8-1/2"–10" 3-1/2" 3-1/2" 3-1/2" 12-5/8" 12-5/8" 12-5/8" ABRSAH-4 ABRSAH-5 ABRSAH-6 AB18-0 AB18-0 AB30-0 PJ50060 PJ50061 PJ50062 For more information, please visit our website, www.americanelectriclighting.com SSA Anchor Base Poles Square Straight Aluminum P R O D U C T O V E R V I E W Intended Use For 4’, 5’ or 6’ shaft width, 8’ to 30’ mounting height. Grounding – Ground lug located immediately inside handhole is tapped for 3/8"-16 UNC grounding bolt (by others). Features Handhole – Rectangular reinforced handhole having nominal dimensions 2" x 4" (4" sq.) or 2-1/2” x 4" (5" or 6" sq.). Handhole cover plate made from aluminum alloy with attachment hardware provided. Shaft – Square, non-tapered shaft made from extruded 6063-T6 or 6061-T6 aluminum alloy Shaft width is 4, 5 or 6 inches. Wall thickness is .125, .188 or .250, depending on mounting height and loading requirements. Anchor Base – Cast from 356-T6 aluminum alloy. Anchor bolt holes are recessed and covered by aluminum caps. Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of 3/4" or 1" diameter steel rod having minimum-yield strength of 55,000 psi. Hardware – All screws, nuts and bolts are made of stainless steel. Top Cap – Weatherproof, cast-aluminum cap is provided for drill mount poles. Finish – Brushed aluminum is standard; optional polyester powder paint and anodized finishes available. Bolt Covers – Nut covers included with each anchor base. Ordering Information: See page 217 (Note: Poles are available only in U.S.) Technical Information EPA (ft ) with 1.3 gust 2 Catalog Number SSA 8 4C SSA 10 4C SSA 12 4C SSA 14 4C SSA 15 4C SSA 16 4C SSA 16 4G SSA 16 5G SSA 18 4C SSA 18 4G SSA 18 5G SSA 20 4C SSA 20 4G SSA 20 5G SSA 20 6G SSA 20 6J SSA 25 5G SSA 25 6G SSA 25 6J SSA 30 6G SSA 30 6J SSA 32 6J SSA 35 6J Nom. Pole Wall mount. Shaft Size Thick. ht. (ft.) (in. x in. x ft.) (in.) 8 10 12 14 15 16 16 16 18 18 18 20 20 20 20 20 25 25 25 30 30 32 35 4.0 x 8.0 4.0 x 10.0 4.0 x 12.0 4.0 x 14.0 4.0 x 15.0 4.0 x 16.0 4.0 x 16.0 5.0 x 16.0 4.0 x 18.0 4.0 x 18.0 5.0 x 18.0 4.0 x 20.0 4.0 x 20.0 5.0 x 20.0 6.0 x 20.0 6.0 x 20.0 5.0 x 25.0 6.0 x 25.0 6.0 x 25.0 6.0 x 30.0 6.0 x 30.0 6.0 x 32.0 6.0 x 35.0 0.125 0.125 0.125 0.125 0.125 0.125 0.188 0.188 0.125 0.188 0.188 0.125 0.188 0.188 0.188 0.250 0.188 0.188 0.250 0.188 0.250 0.250 0.250 80 mph 90 mph 100 mph Max. wt. Bolt Circle (in.) 16.5 11.5 12.4 9.3 8.0 6.9 11.8 15.0 4.9 9.2 16.8 3.3 7.0 13.6 22.0 30.4 7.2 13.2 19.7 7.0 12.2 9.7 6.4 12.6 8.6 9.2 6.7 5.6 4.7 8.5 11.1 3.0 6.4 12.2 1.7 4.6 9.5 15.9 22.6 4.2 8.6 13.8 3.4 7.5 5.4 2.6 9.9 6.5 6.9 4.8 3.9 3.1 6.2 7.5 1.7 4.4 8.9 0.5 2.9 6.6 11.6 17.0 2.0 5.4 9.5 0.8 4.1 2.3 — 300 230 160 120 100 90 130 280 70 100 230 40 80 180 230 300 110 180 250 130 170 160 200 8-1/2-9-5/8 8-1/2-9-5/8 8-1/2-9-5/8 8-1/2-9-5/8 8-1/2-9-5/8 8-1/2-9-5/8 8-1/2-9-5/8 10-1/2-11-1/2 8-1/2-9-5/8 8-1/2-9-5/8 10-1/2-11-1/2 8-1/2-9-5/8 8-1/2-9-5/8 10-1/2-11-1/2 12-13 12-13 10-1/2-11-1/2 12-13 12-13 12-13 12-13 12-13 12-13 Bolt Approx. Size ship wt. (in. x in. x in.) (lbs.) 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 30 x 3 1 x 36 x 4 1 x 36 x 4 3/4 x 30 x 3 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 32 37 40 50 52 54 74 83 57 80 91 62 85 107 155 202 130 180 224 210 258 272 294 INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. A Tapered 3/4” for ground connector C Notes: 1 2 3 4 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° Options: See page 256-257 Brackets: See page 228-229 Pole Data ShaftBolt Base Size Bolt Circle A Base Projection B Anchor Square C Warehouse Bolt Description Anchor Bolt Description Template Number 4"C 4"G 5" 6" 8-1/2–9-5/8" 8-1/2–9-5/8" 10-1/2–11-1/2" 12"-13" 3-1/8" 3-1/8" 3-1/4" 4" 9-15/16" 9-15/16" 11-9/16" 12-1/4" ABSSA-4C ABSSA-4G ABSSA-5 ABSSA-6 AB18-0 AB30-0 AB30-0 AB36-0 PJ50045 PJ50045 PJ50046 PJ50044 Product Guide 221 SSAH Anchor Base Poles Square Straight Aluminum, Hinged P R O D U C T O V E R V I E W Intended Use stainless steel inserts cast into the aluminum base. A cast-aluminum two-piece cover is included. For 4’, 5’ or 6’ shaft width, 10’ to 20’ mounting height. Features Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of 3/4” diameter steel rod having minimum-yield strength of 55,000 psi. Shaft – Square, non-tapered shaft made from extruded 6063-T6 aluminum alloy. Shaft width is 4 or 5 inches. Wall thickness is .125 or .188 depending on mounting height and loading requirements. Handhole – Available as an option, and located 90o to the right of the hinge. Hinged Anchor Base – Cast from A356 aluminum alloy and heat treated to a T6 temper. The shaft inserts into the tilting section of the hinged base and is joined together by continuous circumferential welds at the outside top and inside bottom. The tilting and anchored sections of the hinged base is held in a vertical position by three 1/2"–13 x 2-1/2" stainless steel hex head bolts which attach to Hardware – All screws, nuts and bolts are made of stainless steel. Top Cap – Weatherproof, cast-aluminum cap is provided for drill mount poles. Finish – Brushed aluminum is standard; optional polyester powder paint and anodized finishes available. Ordering Information: See page 217 (Note: Poles are available only in U.S.) Technical Information EPA (ft2) with 1.3 gust INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. Catalog Number SSAH 10 4C SSAH 12 4C SSAH 14 4C SSAH 15 4C SSAH 16 4C SSAH 16 4G SSAH 18 4C SSAH 18 4G SSAH 18 5G SSAH 20 4G SSAH 20 5G Nom. Pole Wall Mount. Shaft Size Thick. Ht. (ft.) (in. x in. x ft.) (in.) 10 12 14 15 16 16 18 18 18 20 20 4 x 4 x 10 4 x 4 x 12 4 x 4 x 14 4 x 4 x 15 4 x 4 x 16 4 x 4 x 16 4 x 4 x 18 4 x 4 x 18 5 x 5 x 18 4 x 4 x 20 5 x 5 x 20 0.125 0.125 0.125 0.125 0.125 0.188 0.125 0.188 0.188 0.188 0.188 80 mph 90 mph 100 mph Max. Wt. Bolt Circle (in.) 13.1 9.6 7.0 6.0 5.0 8.9 3.4 6.8 12.6 5.0 9.9 9.9 7.0 4.9 4.0 3.2 6.2 1.8 4.5 8.8 3.0 6.6 7.5 5.1 3.3 2.6 1.9 4.3 0.7 2.9 6.1 1.6 4.2 100 100 100 100 100 150 100 100 150 150 175 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 9-5/16-10 8-1/2-10 9-5/16-10 Bolt Approx. Size Ship Wt. (in. x in. x in.) (lbs.) 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 30 x 3 48 53 57 60 62 86 67 93 108 100 117 Notes: Two-piece, castaluminum cover 1 2 3 4 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° Options: See page 256-257 Brackets: See page 228-229 Pole Data 222 Product Guide Shaft Base Size Bolt Circle A Bolt Projection B Base Square C Anchor Bolt Description Warehouse Anchor Bolt Description Template Number 4C" 4G" 5" 8-1/2"–10" 8-1/2"–10" 9-5/16"–10" 3-1/2" 3-1/2" 3-1/2" 11-11/16" 11-11/16" 11-11/16" ABSSAH-4C ABSSAH-4G ABSSAH-5 AB18-0 AB30-0 AB30-0 PJ50055 PJ50055 PJ50056 For more information, please visit our website, www.americanelectriclighting.com RSS Anchor Base Poles Round Straight Steel P R O D U C T Intended Use O V E R V I E W Anchor Bolts – Top 12" is galvanized per ASTM A-153. Made of carbon steel bar with minimum-yield strength of 55,000 psi. For 4-1/2” O.D., 8’ to 30’ mounting height. Grounding – Nut holder located immediately inside handhole is provided with 1/2-13 UNC ground bolt and nut. Features Handhole – Nominal 3"x5" handhole is located 18" above base. Cover and attachment hardware provided. Shaft – Weldable grade A500 or A513 carbon steel tubing with minimum yield of 46,000 or 42,000 psi. Uniform wall thickness of .120". Shafts are one-piece construction with a full longitudinal weld. The round, straight tube is uniform in cross-section down length of shaft. Hardware – Fasteners are high-strength galvanized zinc-plated or stainless steel. Top Cap – Plastic cap is provided for drill mount poles. Anchor Base – Fabricated from carbon steel plate (ASTM A-36). 3/4" thickness. Base plate and shaft are circumferentially welded at both top and bottom to provide maximum strength at area of critical stress. Finish – Dark bronze polyester powder paint (DDB) standard; optional polyester powder paint finishes available. Base Cover – Full-base cover finished to match pole. Ordering Information: See page 217 (Note: Poles are available only in U.S.) Technical Information EPA (ft2) with 1.3 gust Catalog Number RSS 8 4-5B RSS 8 4-5B RSS 10 3B RSS 10 4B RSS 10 4-5B RSS 12 3B RSS 12 4B RSS 12 4-5B RSS 14 3B RSS 14 4B RSS 14 4-5B RSS 15 4-5B RSS 16 3B RSS 16 4B RSS 16 4-5B RSS 18 3B RSS 18 4B RSS 18 4-5B RSS 20 3B RSS 20 4B RSS 20 4-5B RSS 20 5B RSS 22 4-5B RSS 25 4B RSS 25 4-5B RSS 25 5B RSS 30 4-5B RSS 30 5B Nom. Pole Wall Mount. Shaft Size Thick. Ht. (ft.) (in. x in. x ft.) (in.) 8 8 10 10 10 12 12 12 14 14 14 15 16 16 16 18 18 18 20 20 20 20 22 25 25 25 30 30 4.5 x 8.0 4.5 x 8.0 3.0 x 10.0 4.0 x 10.0 4.5 x 10.0 3.0 x 12.0 4.0 x 12.0 4.5 x 12.0 3.0 x 14.0 4.0 x 14.0 4.5 x 14.0 4.5 x 15.0 3.0 x 16.0 4.0 x 16.0 4.5 x 16.0 3.0 x 18.0 4.0 x 18.0 4.5 x 18.0 3.0 x 20.0 4.0 x 20.0 4.5 x 20.0 5.0 x 20.0 4.5 x 22.0 4.0 x 25.0 4.0 x 25.0 5.0 x 25.0 4.5 x 30.0 5.0 x 30.0 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 80 mph Max. Wt. 90 mph Max. Wt. 100 mph Max. Wt. 24.5 24.5 10 19.1 24.5 7.7 15.0 19.8 6.0 12.2 16.2 13.1 4.6 9.6 13.1 3.4 7.6 10.5 2.4 6.0 8.5 11.75 4.8 2.85 4.8 7.25 2.3 4.2 615 615 250 480 615 195 390 495 175 305 405 330 125 250 330 90 190 265 100 150 215 300 130 100 130 180 80 150 19.5 19.5 7.7 15.0 19.5 5.8 11.8 15.7 4.4 9.4 12.8 10.2 3.2 7.4 10.2 2.3 5.7 8.2 1.4 4.45 6.6 9.1 3.6 1.95 3.6 5.5 1.5 3 490 490 190 375 490 145 300 395 130 250 320 265 100 185 265 60 180 210 75 150 165 230 90 75 90 150 75 125 15.8 15.8 6.0 12.2 15.8 4.4 9.5 12.7 3.3 7.6 10.3 8.2 2.3 5.9 8.2 1.4 4.5 6.5 — 3.45 5.2 7.25 2.7 1.35 2.7 4.25 1.0 2.25 395 395 175 305 395 130 240 320 90 195 260 205 60 150 205 70 130 165 — 125 130 180 90 75 90 150 60 100 Shaft Base size Bolt circle A Bolt projection B Base square C Anchor Bolt description Warehouse Anchor Bolt description Template number 3 4" 4-1/2" 5" 8" 8" 8" 8" 3-1/4" x 3-1/2" 3-1/4" x 3-1/2" 3-1/4" x 3-1/2" 3-1/4" x 3-1/2" 8" 8" 8" 8" ABRSS-4 ABRSS-4 ABRSS-4 ABRSS-4 AB18-0 AB18-0 AB18-0 AB18-0 PJ50041 PJ50041 PJ50041 PJ50041 1 Mounting Arrangement: (PT) Open Top (T20) 2-3/8" O.D. (2" NPS) 2 Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 55 55 55 70 75 60 80 85 70 90 95 96 80 100 105 90 110 115 100 120 130 145 134 145 145 180 185 210 C Nut Holder Handhole Cover 18” INSTALLATION NOTES: Pole Data Notes: Bolt Bolt Approx. Circle Size Ship Wt. (in.) (in. x in. x in.) (lbs.) Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. 3 Options: See page 256-257 4 Brackets: See page 228-229 Product Guide 223 RTS Anchor Base Poles Round Tapered Steel P R O D U C T O V E R V I E W Intended Use For 30’ to 50’ mounting height. Grounding – Nut holder located immediately inside handhole rim is provided with 1/2" – 13 UNC ground bolt and nut. Features Anchor Bolts – Fabricated from commercial-quality hot-rolled carbon steel with minimum yield strength of 55,000 psi. Bolts have an "L" bend on one end. Shaft – Minimum weldable-grade (ASTM A-595 Grade A), hot-rolled, commercial-quality carbon steel tubing with minimum yield of 55,000 psi. Uniform wall thickness of 11-gauge (0.1196") or 7-gauge (0.1793"). Shafts are constructed with full-length, longitudinal, high-frequency resistance welds. Round in cross-section, having uniform taper of approximately .14" per foot. Hardware – Fasteners are high-strength galvanized zinc-plated or stainless steel. Top Cap – Weatherproof removable top cap provided with all drillmount poles. Anchor Base – Fabricated from hot-rolled carbon steel plate that conforms to ASTM A36. Finish – Dark bronze polyester powder finish (DDB) standard; other architectural colors available. Handhole – Rectangular, reinforced handhole rim having nominal dimensions of 3"x5" for shafts less than 6.25" base diameter and 4"x6.5" for all other shafts. Steel cover with attachment screws included. Handhole is located 18" above base. Ordering Information: See page 217 (Note: Poles are available only in U.S.) INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. Base Cover – Full-base cover standard. Technical Information EPA (ft2) with 1.3 gust Nom. Pole Wall Mount. Shaft Size Thick. Ht. (ft.) (in. x in. x ft.) (in.) Catalog Number RTS 20 5-9B RTS 20 6-5B RTS 25 5-9B RTS 25 7-0B RTS 25 7-0F RTS 30 6-6B RTS 30 8-0B RTS 30 8-0F RTS 35 7-3B RTS 35 8-5B RTS 35 9-5B RTS 39 7-8B RTS 39 9-0B RTS 39 9-0F RTS 45 10-0B RTS 45 10-0F RTS 50 10-0B RTS 50 10-0F 20 20 25 25 25 30 30 30 35 35 35 39 39 39 45 45 50 50 5.9 x 3.1 x 20 6.5 x 3.7 x 20 5.9 x 2.4 x 25 7.0 x 3.5 x 25 7.0 x 3.5 x 25 6.6 x 2.4 x 30 8.0 x 3.8 x 30 8.0 x 3.8 x 30 7.3 x 2.4 x 35 8.5 x 3.6 x 35 9.5 x 4.6 x 35 7.8 x 2.4 x 39 9.0 x 3.6 x 39 9.0 x 3.6 x 39 10.0 x 3.7 x 45 10.0 x 3.7 x 45 10.0 x 3.0 x 50 10.0 x 3.0 x 50 0.125 0.125 0.125 0.125 0.188 0.125 0.125 0.188 0.125 0.125 0.125 0.125 0.125 0.188 0.125 0.188 0.125 0.188 Gauge 80 mph Max. Wt. 90 mph Max. Wt. 100 mph Max. Wt. 11 11 11 11 7 11 11 7 11 11 11 11 11 7 11 7 11 7 19.3 24.2 12.5 20.3 28.5 11.7 18.9 27.5 11.2 18.9 23.2 10.7 17.2 26.1 17.4 25.5 13.2 20.5 482 605 312 507 713 292 473 550 280 472 580 267 430 654 435 639 330 512 15.1 19.3 9.9 16.2 22.5 9.3 14.9 21.6 8.9 15.1 18.2 8.5 13.5 20.6 13.5 20.2 10.6 16.5 377 482 247 405 563 232 373 542 222 377 455 212 338 517 338 505 265 412 12.2 15.6 8 13.1 18.2 7.5 12 17.5 7.1 12.2 14.5 6.6 10.8 16.7 10.6 16.3 8.3 13.6 305 390 200 327 455 187 300 439 177 305 363 165 270 419 265 409 208 340 Bolt Bolt Approx. Circle Size Ship Wt. (in.) in. x in. x in.) (lbs.) 9.0 9.5 9.0 10.0 10.0 9.5 11.0 11.0 10.5 11.5 13.0 11.0 12.5 12.5 13.5 13.5 13.5 13.5 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1-1/4 x 42 x 6 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1-1/4 x 42 x 6 1 x 36 x 4 1-1/4 x 42 x 6 1 x 36 x 4 1-1/4 x 42 x 6 140 160 155 200 280 200 265 380 250 315 370 285 355 515 450 650 475 680 Pole Data Shaft Base Size Bolt Circle A Bolt Projection B Base Square C Anchor Bolt Description Warehouse Anchor Bolt Description 3-1/2"–4-1/4" 3-1/2"–4-1/4" 3-1/2"–4-1/4" 3-3/4"–4-1/2" 3-1/2"–4-1/4" 3-1/2"–4-1/4" 4-1/2–5-1/4" 3-1/2"–4-1/4" 3-3/4"–4-1/2" 3-3/4"–4-1/2" 3-3/4"–4-1/2" 3-3/4"–4-1/2" 4-1/2"–5-1/4" 3-3/4"–4-1/2" 4-1/2"–5-1/4" 10" 10-1/2" 10-7/8" 10-7/8" 10-1/2" 11-1/2" 11-1/2" 11-1/4" 12" 13" 11-1/2" 12-3/8" 12-3/8" 14" 14" ABRTS-5-9B ABRTS-6-5B ABRTS-7-0B ABRTS-7-0F ABRTS-6-6B ABRTS-8-0B ABRTS-8-0F ABRTS-7-3B ABRTS-8-5B ABRTS-9-5B ABRTS-7-8B ABRTS-9-0B ABRTS-9-0F ABRTS-10-B ABRTS-10-F AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 N/A AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 N/A AB36-0 N/A Template Number A C Notes: 1 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) 2 Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° 3 Options: See page 256-257 4 Brackets: See page 228-229 224 Product Guide 5.9" B 6.5" B 7.0" B 7.0" F 6.6" B 8.0" B 8.0" F 7.3" B 8.5" B 9.5" B 7.8" B 9.0" B 9.0" F 10.0" B 10.0" F 9" 9.5" 10" 10" 9.5" 11" 11" 10.5" 11.5" 13" 11" 12.5" 12.5" 13.5" 13.5" For more information, please visit our website, www.americanelectriclighting.com PJ50075 PJ50074 PJ50077 PJ50076 PJ50078 PJ50079 PJ50080 PJ50081 PJ50082 PJ50083 PJ50084 PJ50085 PJ50086 PJ50087 PJ50088 SSS Anchor Base Poles Square Straight Steel P R O D U C T O V E R V I E W Intended Use For 4”, 5” or 6” shaft width, 10’ to 40’ mounting height. diameter steel rod having a minimum-yield strength of 55,000 psi. Grounding – Nut holder located immediately inside handhole rim is provided with a 1/2" x13 UNC ground bolt and nut. Features Handhole – Rectangular, reinforced handhole rim having nominal dimensions of 3"x5" for all shafts. Included is steel cover with attachment screws. Shaft – Weldable-grade, hot-rolled, commercial-quality carbon steel tubing with a minimum yield of 55,000 psi (11-gauge), 50,000 psi (7gauge). Uniform wall thickness of .125" or .188". Shaft is one piece with a longitudinal, electric, resistance weld. Uniformly square in crosssection with flat sides, small corner radii and excellent torsional qualities. Available shaft widths are 4, 5 and 6 inches. Hardware – Fasteners are high-strength, galvanized zinc-plated or stainless steel. Top Cap – Weatherproof, high-strength plastic cap is provided for drill mount poles. Anchor Base – Fabricated from hot-rolled carbon steel plate that meets or exceeds a minimum-yield strength of 36,000 psi. The anchor base is provided with slotted holes. Finish – Dark bronze polyester powder paint (DDB) standard; optional polyester powder paint finishes available. Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of C|v" or 1" Base Cover – Full-base cover finished to match pole. Ordering Information: See page 217 (Note: Poles are available only in U.S.) INSTALLATION NOTES: Technical Information EPA (ft2) with 1.3 gust Nom. Pole Wall Catalog Mount. Shaft Size Thick. Number Ht. (ft.) (in. x in. x ft.) (in.) Bolt Bolt Approx. Circle Size Ship Wt. 80 Max. 90 Max. 100 Max. Gauge mph Wt. mph Wt. mph Wt. (in.) (in. x in. x in.) (lbs.) SSS 10 4C 10 4.0 x 10.0 0.125 11 30.6 765 23.8 595 18.9 473 8–9 3/4 x 18 x 3 SSS 12 4C 12 4.0 x 12.0 0.125 11 24.4 610 18.8 470 14.8 370 8–9 3/4 x 18 x 3 75 90 SSS 14 4C 14 4.0 x 14.0 0.125 11 19.9 498 15.1 378 11.7 293 8–9 3/4 x 18 x 3 100 SSS 16 4C 16 4.0 x 16.0 0.125 11 15.9 398 11.8 295 8.9 223 8–9 3/4 x 18 x 3 115 SSS 18 4C 18 4.0 x 18.0 0.125 11 12.6 315 9.2 230 6.7 168 8–9 3/4 x 18 x 3 125 SSS 20 4C 20 4.0 x 20.0 0.125 11 9.6 240 6.7 167 4.5 150 8–9 3/4 x 18 x 3 140 SSS 20 4G 20 4.0 x 20.0 0.188 7 16.5 415 12.25 310 9.3 240 8–9 3/4 x 30 x 3 198 SSS 20 5C 20 5.0 x 20.0 0.125 11 17.7 443 12.7 343 9.4 235 10–12 1 x 36 x 4 185 SSS 20 5G 20 5.0 x 20.0 0.188 7 28.1 703 21.4 535 16.2 405 10–12 1 x 36 x 4 265 SSS 25 4C 25 4.0 x 25.0 0.125 11 4.8 150 2.6 100 1.0 50 8–9 3/4 x 18 x 3 170 SSS 25 4G 25 4.0 x 25.0 0.188 7 10.8 270 7.7 188 5.4 135 8–9 3/4 x 30 x 3 245 SSS 25 5C 25 5.0 x 25.0 0.125 11 9.8 245 6.3 157 3.7 150 10–12 1 x 36 x 4 225 SSS 25 5G 25 5.0 x 25.0 0.188 7 18.0 350 12.6 350 9.0 250 10–12 1 x 36 x 4 320 SSS 30 4G 30 4.0 x 30.0 0.188 7 6.4 160 4.0 100 2.3 58 8–9 3/4 x 30 x 3 295 SSS 30 5C 30 5.0 x 30.0 0.125 11 4.7 150 2.0 50 — — 10–12 1 x 36 x 4 265 SSS 30 5G 30 5.0 x 30.0 0.188 7 10.7 267 6.7 167 3.9 100 10–12 1 x 36 x 4 380 SSS 30 6G 30 6.0 x 30.0 0.188 7 15.7 392 10.2 257 6.4 160 11–13 1 x 36 x 4 520 SSS 35 5G 35 5.0 x 35.0 0.188 7 5.9 150 2.5 100 — — 10–12 1 x 36 x 4 440 SSS 35 6G 35 6.0 x 35.0 0.188 7 9.5 237 5.0 150 1.8 50 11–13 1 x 36 x 4 540 SSS 39 6G 39 6.0 x 39.0 0.188 7 5.1 128 1.3 33 — — 11–13 1 x 36 x 4 605 Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. C A Pole Data Shaft Base size Bolt Circle A Bolt Projection B Base Square C Anchor Bolt Description Warehouse Anchor Bolt Description Template Number 4"C 4"G 5" 6" 8-1/2" 8-1/2" 10"–12" 11"–13" 2-3/4"–4" 2-3/4"–4" 3-3/8"–4" 3-3/8"–4" 8" 8" 11" 12-1/2" ABSSS-4C ABSSS-4G ABSSS-5 ABSSS-6 AB18-0 AB30-0 AB36-0 AB36-0 PJ50004 PJ50004 PJ50010 PJ50011 Notes: 1 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) 2 Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° 3 Options: See page 256-257 4 Brackets: See page 228-229 Product Guide 225 STS Anchor Base Poles Square Tapered Steel P R O D U C T O V E R V I E W Intended Use For 20’ to 50’ mounting height. Grounding – Nut holder located immediately inside handhole rim is provided with a 1/2" – 13 UNC ground bolt and nut. Features Handhole – Rectangular, reinforced handhole rim having nominal dimensions of 3"x5" for shafts less than 6.375" square and 4"x6.5" for all other shafts. Steel cover with attachment screws included. Handhole is located 18" above base. Shaft – Minimum weldable-grade (ASTM A-595 Grade A) hot-rolled commercial-quality carbon steel tubing with minimum yield of 55,000 psi. Uniform wall thickness of 11-gauge (0.1196") or 7-gauge (0.1793"). Shafts are constructed with full-length longitudinal high-frequency resistance welds and are round in cross-section, having a uniform taper of approximately .11" per foot. Anchor Base – Fabricated from hot-rolled carbon steel plate that conforms with ASTM A36. Anchor Bolts – Fabricated from commercial-quality, hot-rolled carbon steel with minimum-yield strength of 55,000 psi. Bolts have an "L" bend on one end. Ordering Information: See page 217 (Note: Poles are available only in U.S.) Hardware – Fasteners are high-strength galvanized zinc-plated or stainless steel. Top Cap – Weatherproof, removable top cap provided with all drillmount poles. Finish – Dark bronze polyester powder finish (DDB) standard; other architectural colors available. Base Cover – Full-base cover standard Technical Information EPA (ft2) with 1.3 gust Nom. Pole Mount. Shaft Size Ht. (ft.) (in. x in. x ft.) Catalog Number Wall Thick. (in.) Gauge 80 mph Max. Wt. 90 mph Max. wt. 100 mph Max. Wt. 0.125 0.188 0.125 0.188 0.125 0.188 0.125 0.188 0.125 0.188 0.188 0.188 0.188 18.0 30.5 16.8 28.5 13.6 23.6 10.7 23.4 8.6 19.3 16.0 23.5 19.4 452 764 422 713 340 590 269 585 215 483 400 588 485 13.8 24.0 12.6 22.5 9.8 17.9 7.3 17.4 5.4 14.2 11.1 16.6 13.2 345 602 315 563 245 448 184 435 135 355 278 415 332 10.7 19.0 9.5 18.2 7.0 13.7 4.8 13.0 3.0 10.4 7.4 11.4 8.7 268 477 238 455 175 343 120 325 75 260 187 287 218 Bolt Bolt Approx. Circle Size Ship W t. (in.) (in. x in. x in.) (lbs.) INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factorysupplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. STS 20 5-2B STS 20 5-5F STS 25 6-0B STS 25 6-4F STS 30 6-4B STS 30 6-4F STS 35 6-8B STS 35 7-1F STS 39 7-1B STS 39 7-1F STS 45 7-8F STS 45 8-7F STS 50 8-8F If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. 20 20 25 25 30 30 35 35 39 39 45 45 50 5.25 x 3.05 x 20 5.50 x 3.30 x 20 6.00 x 3.25 x 25 6.41 x 3.66 x 25 6.41 x 3.11 x 30 6.41 x 3.11 x 30 6.81 x 2.96 x 35 7.13 x 3.28 x 35 7.18 x 2.92 x 39 7.13 x 2.87 x 39 7.88 x 2.93 x 45 8.75 x 3.80 x 45 8.81 x 3.31 x 50 11 7 11 7 11 7 11 7 11 7 7 7 7 10-3/4 1 x 36 x 4 11 1 x 36 x 4 12 1 x 36 x 4 12-1/2 1 x 36 x 4 12-1/2 1 x 36 x 4 12-1/2 1 x 36 x 4 13 1 x 36 x 4 13-1/2 1 x 36 x 4 13-1/2 1 x 36 x 4 13-1/2 1 x 36 x 4 14-1/2 1 x 36 x 4 15-3/4 1-1/4 x 42 x 6 16 1-1/4 x42 x 6 155 235 205 310 260 375 305 475 345 500 620 730 780 Notes: 1 2 3 4 A Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° Options: See page 256-257 Brackets: See page 228-229 Pole Data 18” C 226 Product Guide Shaft Base Size Bolt Circle A Bolt Projection B Base Square C Anchor Bolt Description Warehouse Anchor Bolt Description Template Number 5.2" B 5.5" F 6.0" B 6.4" F 6.4" B 6.8" B 7.1" F 7.1" B 7.8" F 8.7" F 8.8" F 10-3/4" 11" 12" 12-1/2" 12-1/2" 13" 13-1/2" 13-1/2" 14-1/2" 15-3/4" 16" 3-1/2"–4-1/4" 3-3/4"–4-1/2" 3-1/2"–4-1/4" 4"–4-3/4" 3-1/2"–4-1/4" 3-1/2"–4-1/4" 4-1/4"–5" 3-1/2"–4-1/4" 4"–4-3/4" 4-3/4"–5-1/2" 4-1/2"–5-1/4" 10-3/4" 11" 11-1/2" 11-7/8" 11-7/8" 12-1/4" 12-5/8" 12-5/8" 13-3/8" 14-1/4" 15-1/2" ABSTS-5-2B ABSTS-5-5F ABSTS-6-0B ABSTS-6-4F ABSTS-6-4B ABSTS-6-8B ABSTS-7-1F ABSTS-7-1B ABSTS-7-8F ABSTS-8-7F ABSTS-8-8F AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 N/A N/A PJ50095 PJ50096 PJ50097 PJ50098 PJ50099 PJ50101 PJ50102 PJ50103 PJ50105 PJ50106 PJ50107 For more information, please visit our website, www.americanelectriclighting.com STSH Anchor Base Poles Square Tapered Steel Hinge P R O D U C T O V E R V I E W Intended Use Anchor Bolts – Fabricated from commercial-quality, hot-rolled carbon steel with minimum-yield strength of 55,000 psi. Bolts have an "L" bend on one end. For 20’ to 39’ mounting height. Features Grounding – Nut holder located immediately inside handhole rim is provided with a 1/2" – 13 UNC ground bolt and nut. Shaft – Weldable-grade, hot-rolled, commercial-quality carbon steel having a guaranteed minimum yield strength of 55,000 psi and is supplied in 11-gauge (.1196") or 7-gauge (.1793") nominal thickness. Pole is one-piece construction with full-length, longitudinal, highfrequency, electric-resistance weld. Shaft is square in cross section having flat sides, radiused corners and uniform taper of approximately 0.11 inches per foot of length (4-inch square poles are not tapered). Handhole – Rectangular, reinforced handhole rim having nominal dimensions of 3" x 5" for shafts less than 6.375" square and 4" x 6.5" for all other shafts. Steel cover with attachment screws included. Handhole is located 18" above base. Hardware – Fasteners are high-strength, galvanized zinc-plated or stainless steel. Top Cap – Weather-proof, removable top cap provided with all drillmount poles. Hinge – The hinge includes a stainless steel hinge pin. A flexible wiring guide is provided, passing through the hinge area for wiring protection. Hinge is external. Finish – Dark bronze polyester powder finish (DDB) standard; other architectural colors available. Anchor Base – Fabricated from hot-rolled carbon steel plate that conforms with ASTM A36. Base Cover – Full-base cover is provided. Ordering Information: See page 217 (Note: Poles are available only in U.S.) INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Technical Information EPA (ft ) with 1.3 gust 2 Catalog Number Nom. Pole Wall Mount. Shaft Size Thick. 80 Max. Ht. (ft.) (in. x in. x ft.) (in.) Gauge mph Wt. STSH 20 4F STSH 25 4B STSH 25 6-4B STSH 30 4F STSH 30 6-4B STSH 35 7-1B STSH 35 7-1F STSH 39 7-1F 20 25 25 30 30 35 35 39 4 x 4 x 20 4 x 4 x 25 6.41 x 3.63 x 25 4 x 4 x 30 6.41 x 3.08 x 30 7.18 x 2.88 x 35 7.13 x 2.87 x 35 7.13 x 2.87 x 39 0.188 0.125 0.125 0.188 0.125 0.125 0.188 0.188 7 11 11 7 11 11 7 7 11.6 7.1 18.0 4.0 12.5 7.1 22.0 19.5 217 160 254 120 230 160 155 110 90 Max. mph Wt. 100 mph Max. Wt. 8.5 4.8 13.0 2.1 8.3 3.2 16.9 13.5 6.2 3.1 9.3 0.8 5.1 — 12.1 9.2 217 160 254 120 230 — 155 110 217 160 254 120 230 160 155 110 Bolt Bolt Approx. Circle Size Ship Wt (in.) (in. x in. x in.) (lbs) 8-1/2-10 3/4 x 18 x 3 8-1/2-10 3/4 x 18 x 3 12-1/2 1 x 36 x 4 8-1/2-10 3/4 x 18 x 3 12-1/2 1 x 36 x 4 13-1/2 1 x 36 x 4 13-1/2 1 x 36 x 4 13-1/2 1 x 36 x 4 300 370 355 435 440 540 700 740 Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. Notes: 1 2 3 4 External Hinge Detail Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° Options: See page 256-256 Brackets: See page 228-229 4.0" F 6.4" B 7.1" F 7.1" B Bolt Circle A Bolt Projection B 8-1/2"–10" 3-1/2"–4-1/4" 12-1/2" 3-3/4"–4-1/2" 13-1/2" 4"–4-3/4" 13-1/2" 3-1/2"–4-1/4" Base Square C Anchor Bolt description Warehouse Anchor Bolt description Template Number 9-3/4" 11-7/8" 12-5/8" 12-5/8" ABSTSH4F ABSTSH6-4B ABSTSH7-1F ABSTSH7-1B AB18-0 AB36-0 AB36-0 AB36-0 PJ50091 PJ50092 PJ50093 PJ50094 Winch Ordering Family Winch Shaft size Order nomenclature STSH WCH 4F 6-4B 7-1B 7-1F STSHWCH 4F STSHWCH 6-4B STSHWCH 7-1B STSHWCH 7-1F Shroud Wing Protection Bottom C Pole Data Shaft Base Size Hinge Pin Top Assem A Bolt Slots Winch Detail (accessory) Removable Product Guide 227 Pole Options P R O D U C T O V E R V I E W Anchor Bolts Horizontal Arm Bracket Available in various sizes for use with American Electric Lighting poles. Set includes hex nuts and washers. Anchor bolt is partially galvanized for exposed threads per ASTM-A153. Bolts have minimum-yield strength rating of 55,000 psi, AASHTO M314 GR55. See individual pole catalog pages for anchor bolt sizes and description. Single or twin side-mounted horizontal arm brackets for additional luminaires. Made from 2-3/8," pipe. Upright is 18" from pole; special arm lengths may be available upon request. Arms are rated for luminaires up to 4.5 sq. ft. EPA and 100 lbs. per arm. When ordering, specify location in height and feet above base of pole and orientation from the handhole. Base Covers Option Two-piece, full-base cover. Four fasteners provided to secure pieces together. Finished to match pole. Shipped separately. Standard with steel poles only. H1-18A Aluminum H1-18S Steel HI-18F Fiberglass HI-18C Concrete Option Pole (Square) Dimension (Depth) Dimension SBC4 SBC5 SBC6 SSS 4" SSS 5" SSS 6" 8.75" 11.44" 13.5" x 5.8" x 6.4" x 4" Festoon Outlets Provision provided for mounting duplex outlet. When ordering, specify location in height and feet above base of pole and orientation from the handhole. Description FDL FGL Weight (lbs.) .43 .50 .45 .55 7 11 8 9 Notes: SSS and SSA arm attachment is slightly different from RTA. Arm modifications located on pole to accept arms. Arms shipped as separate item. VD - Vibration Damper For full-base cover on other poles, must order FBC. When ordering separately, specify full pole nomenclature; i.e., FBC for RTA 25 7E. Also specify if pole is existing. Option EPA (sq. ft.) Festoon Duplex Outlet, Less Electric Festoon GFI Outlet, Less Electric It has been found that steady 10-20 mph winds sometimes induce second or higher mode of vibration in lighting poles. Second mode vibration is characterized by the maximum periodic motion occurring at approximately the mid-height of the pole. This type of vibration can result in failure of the pole and/or luminaire. There is no method of predicting destructive light pole vibration. Vibration dampers which alleviate this condition are available. Shipped installed. Handhole Opening Field Installed Vibration Dampener Foundation Notes: RTA FVD - Field installable vibrator damper available upon request. Consult factory. Handheld Cover Plates SSS HHC: For all SSS poles All other poles order as handhole cover for full pole description. Also specify if pole is existing. Nut Covers Four nut covers are standard for RSA and RTA poles only. Tenon Dimensions SSS HHC: For all SSS poles All other poles order as handhole cover for full pole description. Also specify if pole is existing. Tenon Mounting Slipfitters Bolt-on Tenon Square Steel Poles (Order separately) Number of fixtures Tenon O.D. One Two@180° 2-3/8" 2-7/8" 4" T20-190 T25-190 T35-190 T20-280 T25-280 T35-280 Two@90° Three@120° Three@90° Four@90° T20-290 T25-290 T35-290 T20-320 T25-320 T35-320 T20-390 T25-390 T35-390 T20-490 T25-490 T35-490 Threaded couplings and/or nipples can be factory installed. When ordering, specify location in height and feet above base of pole and orientation from the handhole. CPL12 CPL34 CPL1 1/2" 3/4" 1" threaded coupling threaded coupling threaded coupling Threaded Coupling 228 Product Guide NPL12 NPL34 NPL1 1/2" 3/4" 1" threaded nipple threaded nipple threaded nipple" Cat. No. A B C D Wt. (lbs.) SBT-4S1 SBT-5S1 SBT-6S2 2-3/8" 2-3/8" 2-3/8" 3" 4" 5" 13-3/4" 13-3/4" 13-3/4" 5" 5" 5" 7 8 17 D Notes: 1 2 Couplings & Nipples A Stocked in distribution centers. Ordered on a drop-ship basis. Tamperproof Tamperproof (TP): Order as TP. Tamperproof screws provided with base cover. Threaded Nipple For more information, please visit our website, www.americanelectriclighting.com C Aluminum Mounting Brackets Bullhorns and Spokes - order as separate items P R O D U C T Projected area is for bracket only. Bracket projected area is added to luminaire projected area to get total effective projected area (EPA). All brackets have a luminaire rating per tenon of 4.5 sq. ft. projected area and 100 lbs. at a wind velocity of 100 mph (luminaire drag coefficient = 1.0). O V E R V I E W Brackets for Aluminum Poles Only RBA32 RBA28 Finish Natural aluminum. Optional painted finishes available. Plastic cap supplied. Round Pole RBA48 Brackets mount to tenon. Standard is O.D. 2-7/8" - I.D. 2-15/32". Requires T20 tenon (min. 5" tall). Heavy-duty also available for O.D. 4-1/2" - I.D. 4". Requires T35 tenon (min. 6" tall) aluminum poles only. Catalog Number EPA (sq. ft.) Weight (lbs.) Catalog Number EPA (sq. ft.) Weight (lbs.) RBA28 RBA32 RBA38 RBA48 RBA49 1.2 1.7 1.9 2.7 2.2 7.0 14.3 10.5 14.5 17.5 RBA28 HD RBA32 HD RBA38 HD RBA48 HD RBA49 HD 1.3 1.7 2.0 2.8 2.2 8.4 12.7 11.9 16.2 15.8 Square Pole RBA49 RBA38 Brackets for Aluminum Poles Only Brackets flush mount on 4", 5" and 6" square poles. For use with internal sleeve, plain open-top poles, American Electric Lighting poles only. Must be ordered with pole to ensure proper fit. Catalog Number EPA (sq. ft.) Weight (lbs.) SBA28 SBA38 SBA48 SBA49 0.90 1.50 2.25 1.7 12 17 22 22 SBA48 SBA38 SBA49 SBA28 Product Guide 229 Steel Mounting Brackets Bullhorns and Spokes - order as separate items P R O D U C T O V E R V I E W Projected area is for bracket only. Bracket projected area is added to luminaire projected area to get total effective projected area (EPA). All brackets have a luminaire rating per tenon of 4.5 sq. ft. projected area and 100 lbs. at a wind velocity of 100 mph (luminaire drag coefficient = 1.0). Brackets for Steel Poles Only BS28 Finish Dark bronze, standard. Other colors available (consult local American Electric Lighting representative). Plastic cap supplied. Standard Hub Catalog Number EPA (sq. ft.) Weight (lbs.) BS28 BS32 BS38 BS48 BS49 1.0 1.3 1.6 2.3 1.6 21.0 34.0 32.0 44.0 44.0 O.D. 2 -7/8” - I.D. 2-1/2” Requires T20 Tenon (min. 5” tall) Heavy-Duty Hub O.D. 4 1/2” - I.D. 4” Requires T35 Tenon (min. 6” tall) BS35 BS38 230 Catalog Number EPA (sq. ft.) Weight (lbs.) BS28 HD BS32 HD BS38 HD BS48 HD BS49 HD 1.3 2.0 2.2 3.4 2.8 28.0 38.0 38.0 47.0 46.0 BS48 BS49 Finish Brackets for Square Steel Poles Only Dark bronze, standard. Requires T20 (2-3/8" max OD) tenon on pole for mounting Catalog Number EPA (sq. ft.) Weight (lbs.) SBS 28 SBS 38 SBS 49 1.1 1.7 2.1 30.0 42.0 45.0 Product Guide SBS28 SBS38 For more information, please visit our website, www.americanelectriclighting.com SBS49 RTF Anchor Base Poles Round Tapered Fiberglass P R O D U C T O V E R V I E W Intended Use For post-top mounting, 20’ to 45’ mounting height. Handhole – An oval, non-metallic, 2-1/2"x5" handhole secured with a vandal resistant, stainless steel 1/4" socket head screw. Features Hardware – Fasteners are high-strength galvanized zinc-plated or stainless steel. Shaft – Constructed by the filament winding process from thermosetting polyester resin and contains a minimum of 65 percent "E" type fiberglass by weight. The filament windings continuously are applied with uniform tension and are placed on the pole helically at low angles to provide axial strength. Additional windings are placed on the pole in a circular manner to provide compressive strength. Top Cap – Weatherproof, high-strength, plastic cap provided with all drill-mount poles. Finish – The pole is ultraviolet-resistant and pigmented approximately the same color as the final polyurethane coating. Dark bronze (DDB) is standard. Anchor Base – Heavy-duty, A356-T6 aluminum base casting is permanently bonded to the outside of the fiberglass shaft. Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of B|," or 1" diameter steel rod having a minimum-yield strength of 55,000 psi. Ordering Information: See page 217 (Note: Poles are available only in U.S.) Technical Information EPA (ft2) with 1.3 gust Catalog Number INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. RTF 20 7-3X RTF 25 7-3X RTF 30 8-4X RTF 30 8-5X RTF 30 10-5X RTF 35 8-4X RTF 35 8-5X RTF 35 11-2X RTF 40 11-7X RTF 40 11-8X RTF 40 12X RTF 45 11-7X RTF 45 11-9X Nom. Pole Mount. Shaft Size Ht. (ft.) (in. x in. x ft.) 20 25 30 30 30 35 35 35 40 40 40 45 45 7.3 x 4.6 x 20 7.3 x 4.6 x 25 8.4 x 4.6 x 30 8.5 x 4.8 x 30 10.5 x 6.6 x 30 8.4 x 4.6 x 35 8.5 x 4.8 x 35 11.2 x 6.6 x 35 11.7 x 6.2 x 40 11.8 x 6.4 x 40 12.0 x 6.9 x 40 11.7 x 6.2 x 45 11.9 x 6.6 x 45 80 mph 90 mph 100 mph Max. Wt. Bolt Circle (in.) Bolt Approx. Size Ship Wt. (in. x in. x in.) (lbs.) 14.4 9.6 11.2 15.6 28.7 5.5 8.5 21.8 6.4 12.2 25.8 3.9 15.2 11.1 7.3 8.5 12.0 22.4 3.8 6.2 16.6 4.3 8.8 19.3 2.0 10.9 8.9 5.7 6.7 9.5 17.4 2.7 4.7 12.5 2.4 6.0 14.3 0.6 7.6 200 200 100 200 300 100 200 300 165 300 300 300 300 11-1/2 11-1/2 11-1/2 11-1/2 14-1/2 11-1/2 11-1/2 15 15-1/2 15-1/2 15-1/2 15-1/2 15-1/2 1 x 30 x 4 1 x 30 x 4 1 x 30 x 4 1 x 30 x 4 1 x 30 x 4 1 x 30 x 4 1 x 30 x 4 1-1/4 x 36 x 6 1-1/4 x 36 x 6 1-1/4 x 36 x 6 1-1/4 x 36 x 6 1-1/4 x 36 x 6 1-1/4 x 36 x 6 62 75 106 140 202 125 161 248 165 227 317 183 295 Pole Data A 18” B C Shaft Base Size Bolt Circle A Bolt Projection B Base Square C Anchor Bolt Description Template Number 7.3" 8.4" 8.5" 10.5" 11.2 11.7" 11.8" 11.9" 12.0" 11.5" 11.5" 11.5" 14.5" 15" 15.5" 15.5" 15.5" 15.5" 4" 4" 4" 4" 4" 4" 4" 4" 4" 11" 11" 11" 13.3" 13.5" 14" 14" 14" 14" ABRTF-7-3 ABRTF-8-4 ABRTF-8-5 ABRTF-10-5 ABRTF-11-2 ABRTF-11-7 ABRTF-11-8 ABRTF-11-9 ABRTF-12-0 PJ50114 PJ50115 PJ50116 PJ50117 PJ50118 PJ50119 PJ50120 PJ50121 PJ50122 Product Guide 231 RTFDB Direct Buried Poles Round Tapered Fiberglass P R O D U C T O V E R V I E W Intended Use Handhole – An oval, non-metallic, 2-1/2"x5" handhole secured with a vandal-resistant, stainless steel 1/4" socket head screw. For direct burial, 14’ to 35’ mounting height. Hardware – Fasteners are high-strength galvanized zinc-plated or stainless steel. Features Shaft – Constructed by the filament winding process from thermosetting polyester resin and contains a minimum of 65 percent "E" type fiberglass by weight. The filament windings are continuously applied with uniform tension and are placed on the pole helically at low angles to provide axial strength. Additional windings are placed on the pole in a circular manner to provide compressive strength. Top Cap – Weatherproof, high-strength, plastic cap provided with all drill-mount poles. Finish – Ultraviolet-resistant and pigmented approximately the same color as the final polyurethane coating. Dark bronze (DDB) is standard. Ordering Information: See page 217 (Note: Poles are available only in U.S.) INSTALLATION NOTES: Technical Information Do not erect poles without having fixtures installed. EPA (ft2) with 1.3 gust Catalog Number RTFDB 18 6X RTFDB 20 6-6X RTFDB 24 6-7X RTFDB 30 8-3X RTFDB 30 8-4X RTFDB 35 8-4X RTFDB 35 8-5X RTFDB 41 11-8X Nom. Pole Mount. Shaft Size 80 90 Ht. (ft.) (in. x in. x ft.) mph mph 14 16 20 25 25 30 30 35 6.0 x 4.1 x 18 6.6 x 4.1 x 20 6.7 x 4.1 x 24 8.3 x 4.4 x 30 8.4 x 4.6 x 30 8.4 x 4.6 x 35 8.5 x 4.9 x 35 11.8 x 6.4 x 41 14.0 10.0 8.2 6.2 14.5 10.5 14.8 14.3 10.4 7.4 5.8 4.7 11.2 8.0 11.4 10.8 100 mph 7.9 5.5 4.1 3.6 8.9 6.2 9.0 7.8 Approx. Max. Ship Wt. Wt. (lbs.) 150 100 150 100 200 200 300 300 If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. 34 38 46 71 98 116 153 218 Handhole 18” Finish Grade 2’ Wiring Access 232 Product Guide For more information, please visit our website, www.americanelectriclighting.com SSF Anchor Base Poles Square Straight Fiberglass P R O D U C T O V E R V I E W Intended Use For 6’ to 30’ mounting height. Features Hardware – Fasteners are high-strength, galvanized zinc-plated or stainless steel. Shaft – Constructed by the pultrusion process from thermosetting polyester resin and contains a minimum of 65 percent "E" type fiberglass by weight. The fiberglass strands traverse the length of the pole. Top Cap – Weatherproof, high-strength plastic cap provided with all drill-mount poles. Anchor Base – Heavy-duty, A356-T6 aluminum base casting permanently is bonded to the outside of the fiberglass shaft. Finish – Ultraviolet-resistant and pigmented approximately the same color as the final polyurethane coating. Dark bronze (DDB) is standard. Base Cover – Full base cover finished to match pole. Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of B|," or 1" diameter steel rod having a minimum-yield strength of 55,000 psi. Handhole – An oval, non-metallic, 2-1/2" x 5" handhole secured with a vandal-resistant, stainless steel 1/4" socket head screw. INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. SSF 4” Shaft A 13/16” dia. hole (4) Ordering Information: See page 217 (Note: Poles are available only in U.S.) Technical Information EPA (ft2) with 1.3 gust Catalog Number SSF 6 4X SSF 8 4X SSF 10 4X SSF 12 4X SSF 14 4X SSF 16 4X SSF 20 4X SSF 20 5X SSF 25 4X SSF 25 5X SSF 30 5X SSF 30 5XHD Nom. Pole Mount. Shaft Size 80 Ht. (ft.) (in. x in. x ft.) mph 6 8 10 12 14 16 20 20 25 25 30 30 4x4x6 4x4x8 4 x 4 x 10 4 x 4 x 12 4 x 4 x 14 4 x 4 x 16 4 x 4 x 20 5 x 5 x 20 4 x 4 x 25 5 x 5 x 25 5 x 5 x 30 5 x 5 x 30 23.2 16.5 12.0 9.1 6.7 3.7 7.2 12.2 4.2 8.7 4.7 8.6 90 mph 100 mph Max. wt. 17.9 12.6 8.9 6.5 4.4 2.2 1.8 9.1 2.5 6.2 2.8 5.1 14.2 9.8 6.7 4.6 2.8 1.1 0.5 6.9 0.75 4.4 1.9 2.6 150 150 150 100 100 100 150 200 150 200 200 200 8 8 8 8 8 8 8 11 8 11 11 10-12 5/8 x 21 x 3 5/8 x 21 x 3 5/8 x 21 x 3 5/8 x 21 x 3 5/8 x 21 x 3 5/8 x 21 x 3 5/8 x 21 x 3 1 x 30 x 4 5/8 x 21 x 3 1 x 30 x 4 1 x 30 x 4 1 x 30 x 4 18 23 27 31 35 39 80 110 90 115 120 164 Pole Data C SSF 5” Shaft 1-1/4” x 2” slot” (4) A Bolt Bolt Approx. Circle Size Ship Wt. (in.) (in. x in. x in.) (lbs.) Shaft Base Size Bolt Circle A Bolt Projection B Base Square C Anchor Bolt Description Template Number 4" 5" 8" 11" 3" 4" 7.4" 11.1" ABSSF-4 ABSSF-5 PJ50123 PJ50124 Notes: 1 2 3 4 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° Options: See page 256-257 Brackets: See page 228-229 C Product Guide 233 RTCD Anchor Base Poles Round Tapered Concrete P R O D U C T O V E R V I E W Intended Use For 4-1/2” O.D., 8’ to 25’ mounting height. Features: Construction – Centrifugal, pre-stressed concrete with a minimum 28-day compressive strength of 7000 PSI and conform with ASTMC150. Pre-stressing wire reinforcement shall conform to ASTM A-421 and the spiral wire shall conform to ASTM A-82. The spiral reinforcement shall not be less than 13-gauge. The reinforcement continues from the top of the pole over the entire length. The concrete coverage over the reinforcement spiral is 1/2" thick. The raceway opening is 2 inches minimum for wiring. Nominal handhole size of 2.25" x 7". Ground wire runs from top of pole to handhole. Finish – Concrete shall be color throughout with an acrylic coating. Anchor Bolts – Top portion of anchor bolt is galvanized per ASTM A-153. Made of steel rod having a minimum yield strength of 55,000 psi. Ordering Information: See page 217 (Note: Poles are available only in U.S.) INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factorysupplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. Technical Information EPA (ft2) with 1.3 gust Pole Catalog Base Height Anchor "A" Base O.D. Bolt Circle (sq.) (ft. lbs.) (lbs.) 80 90 100 19'-8" 8-1/4" 1" x 36" x 4" 11-1/2" 11" 20,100 600 12.0 11.0 10.0 RTCD 25 8-06X 24'-7" 8-1/16" 1" x 36" x 4" 11-1/2" 11" 19,910 750 12.0 9.0 6.5 RTCD 30 8-62X 29'-6" 8-5/8" 1" x 36" x 4" 11-1/2" 11" 22,540 920 10.0 7.0 5.0 RTCD 35 9-31X 34'-9" 9-5/16" 1" x 36" x 4" 14" 13" 37,500 1,200 12.0 10.0 8.0 RTCD 43 11-31X 42'-8" 11-15/16" 1" x 36" x 4" 16-1/2" 16" 51,050 2,100 12.0 8.0 5.0 B Product Guide Ultimate GL Moment Weight Number A Hand hole 234 Plate RTCD 20 8-25X C D Bolt For more information, please visit our website, www.americanelectriclighting.com RTCDDB Anchor Base Poles Round Tapered Concrete P R O D U C T O V E R V I E W Intended Use For 4-1/2” O.D., 8’ to 25’ mounting height. Features: Construction – Centrifugal, pre-stressed concrete with a minimum 28-day compressive strength of 7000 PSI and conform with ASTM-C150. Prestressing wire reinforcement shall conform to ASTM A-421 and the spiral wire shall conform to ASTM A-82. The spiral reinforcement shall not be less than 13-gauge. The reinforcement continues from the top of the pole over the entire length. The concrete coverage over the reinforcement spiral is 1/2" thick. The raceway opening is 2 inches minimum for wiring. Nominal handhole size of 2.25" x 7". Ground wire runs from top of pole to handhole. Finish – Concrete shall be color throughout with an acrylic coating. Ordering Information: See page 217 (Note: Poles are available only in U.S.) Technical Information EPA(ft2) with 1.3 gust Pole Catalog Ultimate Height Embedded Overall GL Moment Weight Number "A" Base O.D. Depth Length (ft. lbs.) (lbs.) 80 90 100 RTCDDB 20 8-00X 19'-8" 8" 4' - 11' 24'-7" 17,440 750 13.0 11.0 10.0 RTCDDB 25 8-56X 24'-7" 89/16" 4' - 11' 29'-6" 19,910 850 12.0 9.0 6.5 RTCDDB 30 9-25X 29'-6" 91/4" 5' - 3' 34'-9" 22,540 1,200 10.0 7.0 5.0 RTCDDB 35 11-93X 36'-0" 1115/16" 6' - 8' 42'-8" 42,200 2,100 12.0 10.0 8.0 RTCDDB 43 13-33X 42'-8" 13" 6' - 5' 49'-2" 49,300 2,850 12.0 8.0 5.0 INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. Ground Line Product Guide 235 STC Anchor Base Poles Square Tapered Concrete P R O D U C T O V E R V I E W Intended Use Handhole – A 3"x5" handhole is located 24" above ground line and a 21/2" x 7" minimum conduit entrance is located 18" below ground line. Inserts for the handhole and conduit entrance are non-corrosive and weatherproof. Handhole frames and covers conform to ASTM-B240. For direct burial, 16’ to 38’ mounting height. Features Shaft – Concrete mix has a minimum 28-day compressive strength of 6,500 PSI and conforms with ASTM-C150. Prestressing steel reinforcement is uncoated 7 wire, stress relieved strand per ASTMA416. Steel spiral reinforcement conforms to ASTM-A82 and is not less than .120 (11-gauge) diameter. Poles have a continuous taper of 0.165 inches per foot. Grounding – An 18" long, #4 stranded copper pigtail, connected to reinforced strand, is provided at pole top and at cable entrance below grade. Hardware – Fasteners are high-strength galvanized zinc-plated or stainless steel. Top Cap – Weatherproof top cap provided with all drill-mount poles. Finish – Smooth, natural form finish, soft gray color is standard. Ordering Information: See page 217 (Note: Poles are available only in U.S.) INSTALLATION NOTES: Technical Information Do not erect poles without having fixtures installed. EPA (ft ) with 1.3 gust 2 Catalog Number STC 20 7-24X STC 20 9-24X STC 25 8-05X STC 25 10-05X STC 30 8-86X STC 30 10-86X STC 35 9-67X STC 35 11-67X STC 40 12-48X STC 45 13-29X Nom. Mount. Ht. (ft.) Pole Shaft Size (in. x in. x ft.) 80 mph Max wt. 90 mph Max Wt. 100 mph Max. Wt. Approx. Ship Wt. (lbs.) 16 16 20 20 25 25 29 29 34 38 4.0 x 7.24 x 20 6.0 x 9.24 x 20 4.0 x 8.05 x 25 6.0 x 10.05 x 25 4.0 x 8.86 x 30 6.0 x 10.86 x 30 4.0 x 9.67 x 35 6.0 x 11.67 x 35 6.0 x 12.48 x 40 6.0 x 13.29 x 45 22 48 21 44 20 49 17 43 42 41 550 1,220 510 1,050 460 1,090 400 1,010 920 820 16 37 16 34 15 33 12 32 30 31 430 950 390 810 340 830 290 760 670 590 13 29 12 26 11 28 8 24 22 22 330 760 300 640 250 650 200 580 500 420 680 1,110 985 1,530 1,350 2,000 1,800 2,540 3,130 3,795 If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. 3’ x 5’ Handhole with Cover 24” 18” Cast in 1-1/2” Hole @ 45o Finish Grade 236 Product Guide For more information, please visit our website, www.americanelectriclighting.com SPRTC Direct Burial Poles Round Tapered Concrete Sportslighting P R O D U C T O V E R V I E W Intended Use For 6’ to 30’ mounting height. Features Shaft – Concrete mix has a minimum 28-day compressive strength of 11,000 PSI and conforms with ASTM-C150. Prestressing steel reinforcement is uncoated 7 wire, stress relieved strand per ASTMA416. Steel spiral reinforcement conforms to ASTM-A82 and is not less than .203 (5-gauge wire) diameter. Poles have a continuous taper of 0.216 inches per foot. Poles are centrifugally spun and round in cross-section with a hollow center. Handhole – 4"x8" handhole is located 24" above ground line. 4"x8" conduit entrance is located 18" below ground line. 2-1/2"x8" reinforced handhole with flush cover is located at cage/crossarm locations. 1-1/2" coupling wire inlet/outlet is located opposite this handhole. Inserts for handhole and conduit entrance are non-corrosive and weatherproof. Handhole frames and covers conform to ASTM-B240. Grounding – A continuous solid or stranded copper ground wire is cast into the pole. Wire terminates at top of pole to accept a 1/2"x24" lightning rod and approximately 12" below grade. Copper coupling provides a 1/2" tapped insert at pole face for grounding hardware. Hardware – Fasteners are high-strength galvanized zinc-plated or stainless steel. Finish – Smooth, natural form finish, soft gray color is standard. Ordering Information: See page 217 (Note: Poles are available only in U.S.) Technical Information EPA (ft2) with 1.3 gust INSTALLATION NOTES: Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. 24” Catalog Number SPRTC C6 45 7-17 SPRTC C5 45 7-17 SPRTC C4 45 7-17 SPRTC C4 60 7-20 SPRTC C2 60 9-22 SPRTC H1 60 9-22 SPRTC C3 70 9-24 SPRTC C1 70 9-24 SPRTC H2 70 10-24 SPRTC C2 80 9-26 SPRTC C1 80 9-26 SPRTC H2 80 10-26 SPRTC C2 90 9-28 SPRTC C1 90 9-28 SPRTC H2 90 10-28 SPRTC C1 105 9-32 SPRTC H1 105 9-32 SPRTC H3 105 11-34 SPRTC C1 115 9-34 SPRTC H1 115 9-34 SPRTC H2 115 10-34 Nom. Mount. Ht. (ft.) Pole Shaft Size (in. x in. x ft.) 80 mph Max Wt. 90 mph Max Wt. 100 mph 38 38 38 50 50 50 60 60 60 68 68 68 77 77 77 91 91 91 100 100 100 6.75 X 16.47 X 45 6.75 X 16.47 X 45 6.75 X 16.47 X 45 6.75 X 19.71 X 60 8.82 X 21.78 X 60 8.82 X 21.78 X 60 8.82 X 23.94 X 70 8.82 X 23.94 X 70 8.82 X 23.94 X 70 8.82 X 26.1 X 80 8.82 X 26.1 X 80 8.82 X 26.1 X 80 8.82 X 28.26 X 90 8.82 X 28.26 X 90 8.82 X 28.26 X 90 8.82 X 31.5 X 105 8.82 X 31.5 X 105 11.0 X 33.68 X 105 8.82 X 33.66 X 115 8.82 X 33.66 X 115 8.82 X 33.66 X 115 31 39 52 47 85 138 56 90 139 63 85 136 54 78 132 70 99 144 65 96 125 620 780 1,040 893 1,615 2,622 1,064 1,710 2,641 1,197 1,445 2,584 1,026 1,482 2,508 1,330 1,881 2,736 1,235 1,824 2,375 24 30 40 35 65 101 42 69 103 45 65 101 39 56 97 49 74 105 45 70 91 480 600 800 665 1,235 1,919 798 1,311 1,957 855 1,105 1,919 741 1,064 1,843 931 1,406 1,995 855 1,330 1,729 18 23 31 26 48 80 32 52 81 34 48 79 28 42 75 35 54 80 31 50 69 Approx. Max. Ship Wt. Wt. (lbs.) 360 460 589 520 912 1,520 608 988 1,539 646 816 1,501 532 798 1,425 665 1,026 1,520 589 950 1,311 3,400 3,400 3,450 5,450 7,950 8,100 9,900 10,100 10,400 12,300 12,300 12,800 14,850 14,950 15,350 19,250 19,450 22,050 22,350 22,550 22,800 Cast in 4” x 8” Handhole Frame and Cover 1/2” Ground Coupling 18” Cast in 4” x 8” Slot Product Guide 237 SPRTC Crossarm Options For Round Tapered Concrete Sportslighting Poles P R O D U C T O V E R V I E W Angle Iron Crossarms for Concrete Poles Projected area is for the crossarm only. The crossarm projected area is added to the luminaire projected area to get a total effective projected area (EPA). ACRCW6 6-Fixture Angle Arm Pole and Mounting Hardware: see note 2”-6” 3.5” x 5.0” x 0.25” angle 6.0” 13’-6” 6’-9” 6.50” ACRCW5 5-Fixture Angle Arm Pole and Mounting Hardware: see note Angle Iron Crossarms For Concrete Poles 2”-6” 3.5” x 5.0” x 0.25” angle 6.0” 11’ 0” 4’ 3” 6.50” Notes: 1 238 Connecting hardware for crossarm to pole is supplied by others. Bolt holes in c-channel are 0.88” diameter. Product Guide For more information, please visit our website, www.americanelectriclighting.com Catalog Number Arm EPA (sq. ft.) Weight (lbs.) ACRCW2 ACRCW3 ACRCW4 ACRCW5 ACRCW6 1.80 3.00 4.50 5.70 7.00 50.0 86.0 121.0 157.0 193.0 SPRTC Crossarm Options For Round Tapered Concrete Sportslighting Poles P R O D U C T O V E R V I E W Angle Iron Crossarms for Concrete Poles Projected area is for the crossarm only. The crossarm projected area is added to the luminaire projected area to get a total effective projected area (EPA). ACRCW4 4-Fixture Angle Arm Pole and Mounting Hardware: see note 2’ 6” 3.5” x 5.0” x 0.25” angle 6.0” 8’ 6” 4’ 3” 6.50” ACRCW3 3-Fixture Angle Arm Pole and Mounting Hardware: see note 3.5” x 5.0” x 0.25” angle 6.0' 2’ 6”' 1’ 9” 6.0' 6.50” ACRCW2 2-Fixture Angle Arm Pole and Mounting Hardware: see note 3.5” x 5.0” x 0.25” angle 6.0' 3’ 6” 1’ 9” 6.50” Notes: 1 Connecting hardware for crossarm to pole is supplied by others. Bolt holes in c-channel are 0.88” diameter. Product Guide 239 SPRTC Crossarm Options For Round Tapered Concrete Sportslighting Poles P R O D U C T O V E R V I E W Pre-wired Tubular Crossarms for Concrete Poles Pre-wired Tubular Crossarms For Concrete Poles Projected area is for the crossarm only. The crossarm projected area is added to the luminaire projected area to get a total effective projected area (EPA). SPXCW6 Pole and Mounting Hardware: see note 6-Fixture Crossarm Catalog Number EPA (sq. ft.) Weight (lbs.) SPXCW2 SPXCW3 SPXCW4 SPXCW5 SPXCW6 1.00 1.80 2.50 3.20 3.90 23.5 40.0 56.5 73.0 89.5 2’ 6” Gusset (4 places) 2.5” Sched. 40 pipe (2.88” O.D.) 13’ 6” 6.0” 6’ 9” 6.50” SPXCW5 5-Fixture Crossarm Pole and Mounting Hardware: see note Gusset (4 places) 2.5” Sched. 40 pipe (2.88” O.D.) 6.0” 2’ 6” 11’ 0” 6.50” SPXCW4 4-Fixture Crossarm 2.5” Sched. 40 pipe (2.88” O.D.) 4’ 3” SPXCW2 2-Fixture Crossarm Pole and Mounting Hardware: see note Gusset (4 places) Pole and Mounting Hardware: see note 6.0” 2’ 6” 2.5” Sched. 40 pipe (2.88” O.D.) 8’ 6” Gusset (4 places) 6.0” 4’ 3” 6.50” 3’ 6” 1’ 9” 6.50” SPXCW3 3-Fixture Crossarm Pole and Mounting Hardware: see note Gusset (4 places) 2’ 6” 6.0” Notes: 6’ 0” 240 Product Guide 1’ 9” 6.50” For more information, please visit our website, www.americanelectriclighting.com 1 Connecting hardware for crossarm to pole is supplied by others. Bolt holes in c-channel are 0.88” diameter. SPRTS Anchored Base Poles Round Tapered Steel P R O D U C T Intended Use O V E R V I E W For 40’ to 80’ mounting height. Handhole – An oval, reinforced handhole rim having a nominal dimension of 4"x6.5". Steel cover with attachment screws included. Handhole is located 18" above base. Features Grounding – Nut holder located immediately inside handhole rim is provided with 1/2" – 13 UNC ground bolt and nut. Shaft – The cross section shall be round or 16-sided with a 4" bend radius. Each pole is a constant tapered hollow steel section and shall be up to 55 feet in length with a minimum 1-1/2 times diameter slip joint as standard. The pole shaft sections shall be high strength low alloy steel conforming to ASTM A572 Grade 65 or ASTM A595 Grade A. The plate shall be single thickness – no laminations. Anchor Bolts – Fabricated from commercial-quality, hot-rolled carbon steel with minimum-yield strength of 55,000 PSI. Bolts have an "L" bend on one end. Hardware – Fasteners are high-strength galvanized zinc-plated or stainless steel. Top Cap – Weather-proof removable top cap provided with all drillmount poles. Anchor Base – Fabricated from hot-rolled carbon steel plate that conforms to ASTM A36 or ASTM A572 Grade 42. Ordering Information: See page 217 (Note: Poles are available only in U.S.) Technical Information EPA (ft2) with 1.3 gust Catalog Number SPRTS 40 HT01 SPRTS 40 HT02 SPRTS 40 HT03 SPRTS 50 HT01 SPRTS 50 HT02 SPRTS 50 HT03 SPRTS 50 HT04 SPRTS 50 HT05 SPRTS 60 HT01 SPRTS 60 HT02 SPRTS 60 HT03 SPRTS 60 HT04 SPRTS 70 HT01 SPRTS 70 HT02 SPRTS 70 HT03 SPRTS 70 HT04 SPRTS 70 HT05 SPRTS 80 HT01 SPRTS 80 HT02 SPRTS 80 HT03 SPRTS 80 HT04 Nom. Base mount. Dia. ht (ft.) (in.) 40 40 40 50 50 50 50 50 60 60 60 60 70 70 70 70 70 80 80 80 80 — — — — — — — — 5 6.5 6.6 12 6.6 6.6 12 12 12 12 12 13 12 Wall Thick. (in.) Base Dia. (in.) Wall Thick. (in.) 80 mph Max. Wt. 90 mph Max. Wt. 100 mph Max. Wt. Bolt Bolt Num. of Circle Size Anchor (in.) (in. x in. x in.) Bolts — — — — — — — — 0.1196 0.1196 0.1793 0.1793 0.1793 0.1793 0.1793 0.1793 0.1793 0.1793 0.1793 0.1875 0.1793 9 9 10 10 10 11 13 13 11.5 13 13 15.87 13 13 14.57 15.87 16.82 15.87 16.82 17.53 18.7 0.1193 0.1793 0.1793 0.1193 0.1793 0.1793 0.1793 0.2391 0.1793 0.1793 0.2391 0.1875 0.1793 0.2391 0.1875 0.1875 0.1875 0.1875 0.1875 0.2092 0.1875 17.2 26.1 38.6 13.2 20.5 29.9 50.4 69.2 20.0 36.0 49.0 78.0 20.6 23.8 39.0 52.0 65.0 37.0 45.0 58.0 70.0 430 654 965 330 512 748 1,260 1,730 600 1,080 1,470 2,340 515 595 1,170 1,560 1,950 1,110 1,350 1,740 2,100 13.5 20.6 30.6 10.6 16.5 23.5 39.7 55.0 16.0 29.0 40.0 62.0 16.7 19.3 30.0 41.0 53.0 29.0 36.0 46.0 56.0 338 517 765 265 412 588 992 1,375 480 870 1,200 1,860 417 482 900 1,230 1,590 870 1,080 1,380 1,680 10.8 16.7 24.6 8.3 13.6 18.6 31.4 44.2 13.0 22.0 32.0 50.0 13.7 15.9 23.0 33.0 42.0 23.0 28.0 35.0 44.0 270 419 615 208 340 465 785 1,105 390 660 960 1,500 342 397 690 990 1,260 690 840 1,050 1,320 12.5 12.5 13.5 13.5 13.5 15 17 17.5 16 17 17 21 17 17.5 19 21 22.75 21 22.75 23 23 1 x 36 x 4 1.25 x 42 x 6 1.25 x 42 x 6 1 x 36 x 4 1.25 x 42 x 6 1.25 x 42 x 6 1.50 x 54 x 6 1.75 x 84 x 6 1.25 x 42 x 6 1.25 x 42 x 6 1.50 x 54 x 6 1.50 x 54 x 6 1.50 x 54 x 6 1.75 x 84 x 6 1.25 x 42 x 6 1.50 x 54 x 6 1.50 x 54 x 6 1.50 x 54 x 6 1.50 x 54 x 6 1.50 x 54 x 6 1.50 x 54 x 6 4 4 4 4 4 4 4 4 4 6 6 6 4 4 6 6 6 6 6 6 8 INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. 4-Bolt 6-Bolt 8-Bolt Handhole Handhole Handhole Product Guide 241 SPRTS Crossarm Options For Round Tapered Steel Sportslighting Poles P R O D U C T O V E R V I E W Angle Iron Crossarms for Steel Poles Pre-wired Tubular Crossarms For Concrete Poles Projected area is for the crossarm only. The crossarm projected area is added to the luminaire projected area to get a total effective projected area (EPA). ACR6 6-Fixture Angle Arm 13’ 0” Catalog Number Arm EPA (sq. ft.) Weight (lbs.) ACR2 ACR3 ACR4 ACR5 ACR6 1.98 3.12 4.53 5.95 7.37 34.0 54.0 78.0 103.0 127.0 2’ 6” 1.75” 8” 6’ 2” 1.75” ACR5 ACR4 5-Fixture Angle Arm 4-Fixture Angle Arm 8’ 0” 10’ 6” 2’ 6” 1.75” 2’ 6” 3’ 8” 4’ 11” 8” 3’8” 8” 4’ 11” 1.75” 2.00” ACR3 ACR2 3-Fixture Angle Arm 2-Fixture Angle Arm 5’ 6” 2’ 6” 2’ 5” 3’ 6” 3’ 0” 1.75” 1’ 5” 2’ 5” 2.00” 242 Product Guide 1.75” For more information, please visit our website, www.americanelectriclighting.com 1.75” 1’ 5” SPRTS Crossarm Options For Round Tapered Steel Sportslighting Poles P R O D U C T O V E R V I E W Tubular Crossarms for Steel Poles Tubular Crossarms For Steel Poles Projected area is for the crossarm only. The crossarm projected area is added to the luminaire projected area to get a total effective projected area (EPA). Catalog Number EPA (sq. ft.) Weight (lbs.) CR2 CR3 CR4 CR5 CR6 CR7 CR8 1.28 2.45 3.21 4.17 5.13 6.10 7.06 44.0 65.0 98.0 116.0 150.0 176.0 271.0 CR8 8-Fixture Crossarm 22’ 0” 3’ 0” 3” Shed 40 pipe CR7 CR6 7-Fixture Crossarm 6-Fixture Crossarm 16’ 0” 19’ 0” 3’ 0” 3” Shed 40 pipe 3’ 0” 3” Shed 40 pipe CR5 CR4 5-Fixture Crossarm 4-Fixture Crossarm 13’ 0” 10’ 0” 13’ 0” 3’ 0” 3” Shed 40 pipe 3” Shed 40 pipe 3’ 0” CR3 CR2 3-Fixture Crossarm 2-Fixture Crossarm 4’ 0” 7’ 0” 3” Shed 40 pipe 3” Shed 40 pipe 3’ 0” 3’ 0” Product Guide 243 RTAU Anchor Base Poles / Mounting Arm Combo Round Tapered Aluminum Pole with Mounting Arm P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N Intended Use 20’ to 40’ fixture mounting. Pole Grounding System — A ground lug located immediately inside the handhole is tapped for 3/8"-16 UNC ground bolt (not supplied). Features Pole Installation — Anchor bolts — Top portion of anchor bolt is galvanized per ASTM A-153. Made of steel rod having a minimum yield strength of 55,000 psi. Pole Construction — Spun-tapered seamless 6063 alloy aluminum tubing, heat treated to produce a T6 temper. Circumferential satinbrushed finish. The shaft is cone-tapered to the butt diameter. Mounting Arm Construction — Body of the mounting arm is tapered aluminum alloy 6063-T6 tube with a 2-3/8" O.D. (2" NPS) pipe size at the luminaire end. The pole end of the arm is welded to an aluminum alloy 6063-T6 mounting plate. Three sections cast from A356 alloy aluminum; the anchor base is heat treated to a T6 condition. The anchor base telescopes the pole shaft and is circumferentially welded at both the top and the bottom. Welding follows AWS and CSA standards. Arms are chemically cleaned after fabrication. A nominal 3" x 5" or 4" x 6" reinforced flush-covered handhole is centered 18" above the base. Mounting — The mounting plate is designed to be bolted to the shaft using four 1/2" stainless steel bolts, nuts and washers. A grommet is provided for the 1-1/4" diameter wiring hole between the pole shaft and the bracket arm. Cast aluminum cap provided. All screws, nuts and bolts are made of stainless steel. A356 nut covers are included with each anchor base unless otherwise specified. Mounting Arm Finish — Satin aluminum is standard. Optional polyester powder paint and anodized finishes available. Pole Finish — Brushed aluminum (BA) is standard. Optional polyester powder paint and anodized finishes available. Example: R T A U 2 0 6 G B M A U S 8 V D B A A E L Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, please add AEL after the last option RTAU Shaft/Arm type Fixture mounting height RTAU 20 - 40 feet (See chart on page 246) Nominal Shaft Base Size/ Wall Thickness Options Mounting BMA (See chart on page 246) Bolt-on mast arm Arm Length1 US4 US6 US8 Notes: 1 Some restrictions apply, chart on page 246 for details. 2 Specify location and orientation when ordering option. For 1st "x": Specify the height in feet above base of pole. Use two digits to specify height: Example: 5 ft = 05 and 20 ft = 20 For 2nd "x": Specify orientation from handhole (A, B, C, D) Refer to the Handhole Orientation diagram on this page. 3 Horizontal arm is 18" x 2-3/8" O.D. tenon standard. 4 Other colors available, please contact local AEL representative. 244 Product Guide 4' arm length 6' arm length 8' arm length C D Shipped Installed L/AB Less anchor bolts FBC Full base cover VD Vibration damper TP Tamper proof HAAxx2,3 Horizontal arm Bracket (1 fixture) FDLxx2 Festoon outlet less electrical FGLxx2 Festoon GFI outlet less electrical 12CPxx2 1/2" coupling 34CPxx2 3/4" coupling 1CPxx2 1" coupling 12NPxx2 1/2" threaded nipple 34NPxx2 3/4" threaded nipple 1NPxx2 1" threaded nipple HHxx2 Extra handhole B Arm located on side B A Handhole For more information, please visit our website, www.americanelectriclighting.com Architectural Colors (powder finish)4 Standard Colors BA Brushed aluminum (std) DDB Dark bronze DWH White DBL Black Class 1 Arch. Anodize ABL Black ADB Dark bronze ANA Natural RTAU Anchor Base Poles / Mounting Arm Combo Round Tapered Aluminum Pole with Twin Mounting Arms P R O D U C T O V E R V I E W Intended Use / O R D E R I N G I N F O R M AT I O N 20’ to 40’ fixture mounting. Pole Grounding System — A ground lug located immediately inside the handhole is tapped for 3/8"-16 UNC ground bolt (not supplied). Features Pole Installation — Anchor bolts — Top portion of anchor bolt is galvanized per ASTM A-153. Made of steel rod having a minimum yield strength of 55,000 psi. Pole Construction — Spun-tapered seamless 6063 alloy aluminum tubing, heat treated to produce a T6 temper. Circumferential satinbrushed finish. The shaft is cone-tapered to the butt diameter. Mounting Arm Construction — Body of the mounting arm is tapered aluminum alloy 6063-T6 tube with a 2-3/8" O.D. (2" NPS) pipe size at the luminaire end. The pole end of the arm is welded to an aluminum alloy 6063-T6 mounting plate.Welding follows AWS and CSA standards. Arms are chemically cleaned after fabrication. Cast from A356 alloy aluminum, the anchor base is heat treated to a T6 condition. The anchor base telescopes the pole shaft and is circumferentially welded at both the top and the bottom. Mounting — The mounting plate is designed to be bolted to the shaft using four 1/2" stainless steel bolts, nuts and washers. A grommet is provided for the 1-1/4" diameter wiring hole between the pole shaft and the bracket arm. A nominal 3" x 5" or 4" x 6" reinforced flush-covered handhole is centered 18" above the base. Cast aluminum cap provided. Mounting Arm Finish — Satin aluminum is standard. Optional polyester powder paint and anodized finishes available. All screws, nuts and bolts are made of stainless steel. A356 nut covers are included with each anchor base unless otherwise specified. Pole Finish — Brushed aluminum (BA) is standard. Optional polyester powder paint and anodized finishes available. Example: R T A U 2 0 6 G B M A 2 U S 4 B A V D A E L Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option. RTAU Shaft/Arm Type Fixture Mounting Height RTAU 20 - 40 feet Nominal Shaft Base Size/ Wall Thickness Options Mounting BMA Bolt-on mast arm (See chart on page 246) Arm Length1 2US4 2US6 2US8 Notes: 1 Some restrictions apply, see chart on page 246 for details. 2 Specify location and orientation when ordering option. For 1st "x": Specify the height in feet above base of pole. Use two digits to specify height: Example: 5 ft = 05 and 20 ft = 20 For 2nd "x": Specify orientation from handhole (A, B, C, D) Refer to the Handhole Orientation diagram on this page. 3 Horizontal arm is 18" x 2-3/8" O.D. tenon standard. 4 Other colors available, please contact your local American Electric Lighting representative. 4' arm length 6' arm length 8' arm length C D Shipped Installed L/AB Less anchor bolts FBC Full base cover VD Vibration damper TP Tamper proof HAAxx2,3 Horizontal arm Bracket (1 fixture) FDLxx2 Festoon outlet less electrical FGLxx2 Festoon GFI outlet less electrical 12CPxx2 1/2" coupling 34CPxx2 3/4" coupling 1CPxx2 1" coupling 12NPxx2 1/2" threaded nipple 34NPxx2 3/4" threaded nipple 1NPxx2 1" threaded nipple HHxx2 Extra handhole Architectural Colors (powder finish)3 Standard Colors BA Brushed Aluminum (std) DDB Dark bronze DWH White DBL Black Class 1 Arch. Anodize ABL Black ADB Dark bronze ANA Natural B Arms located on sides B & D A Handhole Product Guide 245 RTAU Anchor Base Poles / Mounting Arm Combo Round Tapered Aluminum Pole with Twin Mounting Arms P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N Technical Information EPA (ft2) with 1.3 gust 246 AEL Catalog Number Fixture Mtg. Height1 (ft.) Mtg. Arm length (ft.) Pole Shaft Dia. (in. x in.) RTAU 20 6G BMA 2US4 RTAU 20 6G BMA 2US6 RTAU 20 6G BMA 2US8 RTAU 20 6E BMA 2US4 RTAU 20 6E BMA 2US6 RTAU 20 6E BMA 2US8 RTAU 25 6G BMA 2US4 RTAU 25 6E BMA 2US6 RTAU 25 7E BMA 2US6 RTAU 25 7E BMA 2US4 RTAU 25 7E BMA 2US6 RTAU 25 7E BMA 2US8 RTAU 30 8G BMA 2US4 RTAU 30 8G BMA 2US6 RTAU 30 8G BMA 2US8 RTAU 30 8E BMA 2US4 RTAU 30 8E BMA 2US6 RTAU 30 8E BMA 2US8 RTAU 30 7E BMA 2US4 RTAU 30 7E BMA 2US6 RTAU 30 7E BMA 2US8 RTAU 35 8G BMA 2US4 RTAU 35 8G BMA 2US6 RTAU 35 8J BMA 2US4 RTAU 35 8J BMA 2US6 RTAU 35 8J BMA 2US8 RTAU 35 8E BMA 2US6 RTAU 35 8E BMA 2US8 RTAU 40 8G BMA 2US8 RTAU 40 8L BMA 2US6 RTAU 40 8J BMA 2US6 RTAU 40 8J BMA 2US8 RTAU 40 8J BMA 2US4 20 20 20 20 20 20 25 25 25 25 25 25 30 30 30 30 30 30 30 30 30 35 35 35 35 35 35 35 40 40 40 40 40 4 6 8 4 6 8 4 6 6 4 6 8 4 6 8 4 6 8 4 6 8 4 6 4 6 8 6 8 8 6 6 8 4 4x6 4x6 4x6 4x6 4x6 4x6 4x6 4x7 4x7 4x7 4x7 4x7 4.5 x 8 4.5 x 8 4.5 x 8 4.5 x 8 4.5 x 8 4.5 x 8 4.5 x 7 4.5 x 7 4.5 x 7 4.5 x 8 4.5 x 8 4.5 x 8 4.5 x 8 4.5 x 8 4.5 x 8 4.5 x 8 4.5 x 8 4.5 x 8 4.5 x 8 4.5 x 8 4.5 x 8 Product Guide Wall Thickness (in.) 0.188 0.188 0.188 0.156 0.156 0.156 0.188 0.156 0.188 0.156 0.156 0.156 0.188 0.188 0.188 0.156 0.156 0.156 0.156 0.156 0.156 0.188 0.188 0.250 0.250 0.250 0.156 0.156 0.188 0.219 0.250 0.250 0.250 (Max per Arm) EPA ft2 with 1.3 Gust 80 mph 90 mph 100 mph 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1.9 0.8 1.3 1.8 2 2 1.8 0.7 2 2 2 2 1.8 0.8 2 1.8 2 1.8 1.3 2 2 2 1.3 2 2 2 1.9 0.9 2 2 1.9 0.8 1.5 0.9 n/a 0.6 0.8 1.5 1.3 0.8 n/a 2 1.9 0.9 1.3 0.8 n/a 1.3 0.8 0.9 0.8 n/a 2 2 1.1 n/a 1.1 1.3 2 0.8 n/a 1.4 For more information, please visit our website, www.americanelectriclighting.com Max. Weight per Arm (lbs.) Bolt Circle (in.) Bolt Size (in.) App. Ship Weight (lbs.) 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 9-10 9-10 9-10 9-10 9-10 9-10 9-10 9-10 10-11 10-11 10-11 10-11 11-12 11-12 11-12 11-12 11-12 11-12 10-11 10-11 10-11 11-12 11-12 11-12 11-12 11-12 11-12 11-12 11-12 11-12 11-12 11-12 11-12 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 30 x 3 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 42 1 x 36 x 42 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 107 110 112 94 97 99 117 120 135 144 147 134 183 186 188 160 163 165 156 159 161 14 17 263 266 268 190 192 241 271 301 303 298 RTAU Anchor Base Poles / Mounting Arm Combo Round Tapered Aluminum Pole with Twin Mounting Arms P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N Notes: 1. Denotes fixture mounting heights, NOT nominal pole height. Shaft Base Size Bolt Circle A Bolt Projection B 6" 7" 8" 9"–10" 10"–11" 11"–12" 3-1/2" 4-1/8" 4-1/4" Base Anchor Warehouse Template Square Bolt Anchor Bolt Number C Description Description 10" 10-1/2" 11-1/2" ABRTA-6 ABRTA-7 ABRTA-8 AB30-0 AB36-0 AB36-0 PJ50033 PJ50034 PJ50035 IMPORTANT: • Do not erect poles without having fixtures installed. • Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use factory template. • If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. • Installation requires grout be packed under base to ensure full contact with foundation. Peripherally reinforced handhole door Cast aluminum nut cover Grout 18” B IMPORTANT: • These specifications are intended for general purposes only. American Electric Lighting reserves the right to change material or design without prior notice, in a continuing effort to upgrade its products. Product Guide 247 RTSU Anchor Base Poles / Mounting Arm Combo Round Tapered Steel Pole with Single Mounting Arm P R O D U C T O V E R V I E W / O R D E R I N G Intended Use I N F O R M AT I O N Pole Finish — Galvanized steel (GALV) is standard. Optional polyester powder paint finishes available. 20’ to 40’ fixture mounting. Pole Grounding System — A ground lug is located immediately inside the handhole rim. Features Pole Construction — Weldable-grade hot-rolled, commercial-quality carbon steel tubing with a minimum yield of 55,000 psi. Uniform wall thickness of 11-gauge (0.1196") or 7-gauge (0.1793"). Shafts are onepiece construction with a full-length longitudinal high-frequency resistance weld. Round in cross-section having a uniform taper of approximately .14" per foot. Anchor base is fabricated from hot-rolled carbon steel plate that conforms to ASTM A36. A reinforced handhole having nominal dimensions of 3" x 5" for shafts less than 6.25" base diameter and 4" x 6.5" for all other shafts. Cover with attachment screws included. Handhole is located 18" above the base. Pole Installation — Anchor bolts — Fabricated from commercialquality, hot-rolled carbon steel with minimum yield strength of 55,000 psi. Bolts have an "L" bend on one end. Mounting Arm Construction — Body is 2-3/8" O.D. (2" NPS) galvanized steel tube (sch. 40 material, min. yield strength 36,000 psi). Welding follows AWS standards. Arms are galvanized after fabrication. Mounting Arm Hardware — Mounting plate is designed to be bolted to the shaft using a 1/2" steel bolt Simplex mount. Single-bolt (US4, US6, US8) or multi-bolt design (US10, US12). Mounting Arm Finish— Galvanized steel (GALV) is standard. Optional polyester powder paint finishes available. Weatherproof, removable top cap provided. Fasteners are high-strength galvanized zinc-plated or stainless steel. Example: R T S U 2 5 S M P U S 4 G A L V V D A E L Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option. RTSU Shaft/Arm type Fixture Mounting Height Nominal Shaft Base Size/ Wall Thickness 20 - 40 feet (See chart on page 249) (See chart on page 249) RTSU Notes: 1 Some restrictions may apply, see chart on page 249 for details. 2 Specify location and orientation when ordering option. For 1st "x":Specify the height in feet above base of pole. Use two digits to specify height: Example: 5 ft = 05 and 20 ft = 20 For 2nd "x":Specify orientation from handhole (A, B, C, D) Refer to the Handhole Orientation diagram on page 249. 3 Horizontal arm is 18" x 2-3/8" O.D. tenon standard. 4 Other colors available, please contact your local American Electric Lighting representative. 248 Product Guide Options Mounting / Arm Length1 SMP US4 Single-bolt simplex mount, 4' arm length SMP US6 Single-bolt simplex mount, 6' arm length SMP US8 Single-bolt simplex mount, 8' arm length MSMP US10 Multi-bolt simplex mount , 10' arm length MSMP US12 Multi-bolt simplex mount , 12' arm length Shipped Installed L/AB Less anchor bolts FBC Full base cover VD Vibration damper TP Tamperproof HASxx1,2,3 Horizontal arm Bracket (1 fixture) FDLxx2 Festoon outlet less electrical FGLxx2 Festoon GFI outlet less electrical 12CPxx2 1/2" coupling 34CPxx2 3/4" coupling 1CPxx2 1" coupling 12NPxx2 1/2" threaded nipple 34NPxx2 3/4" threaded nipple 1NPxx2 1" threaded nipple HHxx2 Extra handhole For more information, please visit our website, www.americanelectriclighting.com Architectural Colors (powder finish)4 Standard Colors GALV Galvanized Finish (std) DDB Dark bronze DWH White DBL Black RTSU Anchor Base Poles / Mounting Arm Combo Round Tapered Steel Pole with Single Mounting Arm P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N Technical Information EPA (ft2) with 1.3 gust Fixture Mtg. Height1 (ft.) AEL Catalog Number RTSU 20 5-9B SMP US4 RTSU 20 5-9B SMP US6 RTSU 20 5-9B SMP US8 RTSU 25 5-9B SMP US4 RTSU 25 5-9B SMP US6 RTSU 25 5-9B SMP US8 RTSU 20 6-5B SMP US4 RTSU 20 6-5B SMP US6 RTSU 20 6-5B SMP US8 RTSU 25 7B SMP US4 RTSU 25 7B SMP US6 RTSU 25 7B SMP US8 RTSU 25 7B MSMP US10 RTSU 25 7B MSMP US12 RTSU 30 8B SMP US4 RTSU 30 8B SMP US6 RTSU 30 8B SMP US8 RTSU 30 8B MSMP US10 RTSU 30 8B MSMP US12 RTSU 35 8-5B SMP US4 RTSU 35 8-5B SMP US6 RTSU 35 8-5B SMP US8 RTSU 35 8-5B MSMP US10 RTSU 35 8-5B MSMP US12 RTSU 40 9B SMP US4 RTSU 40 9B SMP US6 RTSU 40 9B SMP US8 RTSU 40 9F MSMP US10 RTSU 40 9F MSMP US12 20 20 20 25 25 25 20 20 20 25 25 25 25 25 30 30 30 30 30 35 35 35 35 35 40 40 40 40 40 Mtg. Arm length (ft.) Pole Base Diameter (.14 taper rate) Wall Thickness (in.) 4 6 8 4 6 8 4 6 8 4 6 8 10 12 4 6 8 10 12 4 6 8 10 12 4 6 8 10 12 5.9 5.9 5.9 5.9 5.9 5.9 6.5 6.5 6.5 6.8 6.8 6.8 6.8 6.8 8 8 8 8 8 8.5 8.5 8.5 8.5 8.5 9 9 9 9 9 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.180 0.180 (Max per Arm) Max Weight EPA ft2 w/ 1.3 Gust up to per Arm 100 mph (lbs.) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 Bolt Circle (in.) Bolt Size (in.) 9 9 9 9 9 9 9.5 9.5 9.5 10.5 10.5 10.5 10.5 10.5 11 11 11 11 11 11.5 11.5 11.5 11.5 11.5 12.5 12.5 12.5 12.5 12.5 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1.25 x 42 x 6 1.25 x 42 x 6 Notes: 1. Denotes fixture mounting heights, NOT nominal pole height. Shaft Base Size Bolt 1 Circle A Bolt Projection B Base Square C Anchor Warehouse Template Bolt Anchor Bolt Number Description Description 5.9" B 6.5" B 7.0" B 8.0" B 8.5" B 9.0" B 9.0" F 9" 9.5" 10" 11" 11.5" 12.5" 12.5" 3-1/2"–4-1/4" 3-1/2"–4-1/4" 3-1/2"–4-1/4" 3-1/2"–4-1/4" 3-3/4"–4-1/2" 3-3/4"–4-1/2" 4-1/2"–5-1/4" 10" 10-1/2" 10-7/8" 11-1/2" 12" 12-3/8" 12-3/8" ABRTS-5-9B ABRTS-6-5B ABRTS-7-0B ABRTS-8-0B ABRTS-8-5B ABRTS-9-0B ABRTS-9-0F AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 N/A PJ50075 PJ50074 PJ50077 PJ50079 PJ50082 PJ50085 PJ50086 IMPORTANT: • Do not erect poles without having fixtures installed. • Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use factory template. • If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. • Installation requires grout be packed under base to ensure full contact with foundation. A C IMPORTANT: • These specifications are intended for general purposes only. American Electric Lighting reserves the right to change material or design, without prior notice, in a continuing effort to upgrade its products. Product Guide 249 AMAW / SMAW AMAW: Aluminum Mounting Arm, Wood Poles SMAW: Steel Mounting Arm, Wood Poles P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N Steel: Body is galvanized steel tube (per ASTM A-123) constructed from A500 Grade B steel. Base is 3/16" plate. Intended Use Mounting roadway fixtures to wood poles. Welding follows AWS standards. Arms are galvanized after fabrication. Features Finish: Satin aluminum or galvanized steel is standard. Optional polyester powder finishes available. Construction Hardware not included. Aluminum: Body is schedule 10 (T14) or schedule 40 (T20) aluminum pipe 6005-T5. Base is 3/8" aluminum plate. Welding follows AWS standard. Arms are pressure-washed after fabrication. Example: A M A W T 2 0 U S 4 S A A E L Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option Pipe Size Series AMAW SMAW T14 T20 Arm Length (feet) 1 - 2/3” O.C. (1 - 1/4” NPS) 2 - 3/8” O.D. (2” NPS) US2-5 US4 US6 US8 2-1/2' arm length 4' arm length 6' arm length1 8' arm length1 Notes: 1 2 250 Not available with AMAWT14 Other colors available, please contact your local American Electric Lighting representative Product Guide For more information, please visit our website, www.americanelectriclighting.com Options Standard Finish SA Satin aluminum (standard w/ AMAW) GALV Galvanized steel (standard w/ SMAW) Architectural Colors (powder finish)2 Standard Colors DDB Dark bronze DWH White DBL Black AMAW / SMAW AMAW: Aluminum Mounting Arm, Wood Poles SMAW: Steel Mounting Arm, Wood Poles P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N AMAW / SMAW AEL Catalog Number Nominal Arm Length (ft.) Dimensions (in.) A B C Weight (lbs.) (Max per Arm) EPA ft2 w/ 1.3 Gust up to 100mph Max Weight per arm (lbs.) AMAW T14 US2-5 AMAW T14 US4 AMAW T14 US6 AMAW T20 US2-5 AMAW T20 US4 AMAW T20 US6 AMAW T20 US8 2'6" 4' 6' 2'6" 4' 6' 8' 30 42 66 30 42 66 90 15 19 24 15 10 24 30 10 10 12 10 10 12 15 3 4 6 6 7 10 12 2 2 2 2 2 2 2 76 76 76 76 76 76 76 SMAW T14 US2-5 SMAW T14 US4 SMAW T14 US6 SMAW T14 US8 SMAW T20 US2-5 SMAW T20 US4 SMAW T20 US6 SMAW T20 US8 2'6" 4' 6' 8' 2'6" 4' 6' 8' 30 42 66 90 30 42 66 90 15 19 24 30 15 19 24 30 10 10 12 15 10 10 12 15 9 11 15 20 15 18 24 30 2 2 2 2 2 2 2 2 76 76 76 76 76 76 76 76 IMPORTANT: CAUTION: • These specifications are intended for general purposes only. American Electric Lighting reserves the right to change material or design without prior notice in a continuing effort to upgrade its products. • The arms described herein are designed for applications in areas of normal winds. Consult the factory prior to the design of systems to be mounted on structures such as bridges or buildings, or areas known to have abnormal winds such as airports or coastal areas. Failure to consider these factors in the system design could result in the failure of the pole or mast arm, and consequently in personal injury or property damage. A C B .562" Diameter Product Guide 251 AMAC / SMAC AMAC: Aluminum Mounting Arm, Concrete Poles SMAC: Steel Mounting Arm, Concrete Poles P R O D U C T O V E R V I E W / O R D E R I N G Intended Use I N F O R M AT I O N Steel: Body is galvanized steel tube (per ASTM A-123) constructed from A500 Grade B steel. Base is 3/16" plate. Mounting roadway fixtures to concrete poles. Welding follows AWS standards. Arms are galvanized after fabrication. Features Finish: Satin aluminum or galvanized steel is standard. Optional polyester powder paint finishes available. Construction Hardware not included. Aluminum: Body is schedule 10 (T14) or schedule 40 (T20) aluminum pipe 6005-T5. Base is 3/8" aluminum plate. Welding follows AWS standard. Arms are pressure-washed after fabrication. Example: A M A C T 2 0 U S 4 S A A E L Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option Pipe Size Series AMAC SMAC T14 T20 Arm Length (feet) 1 - 2/3” O.C. (1 - 1/4” NPS) 2 - 3/8” O.D. (2” NPS) US4 US6 US8 4'arm length 6' arm length1 8' arm length1 Notes: 1 Not available with AMAWT14 2 Other colors available, please contact your local American Electric Lighting representative 252 Product Guide For more information, please visit our website, www.americanelectriclighting.com Options Standard Finish SA Satin aluminum (standard w/ AMAW) GALV Galvanized steel (standard w/ SMAW) Architectural Colors (powder finish)2 Standard Colors DDB Dark bronze DWH White DBL Black AMAC / SMAC AMAC: Aluminum Mounting Arm, Concrete Poles SMAC: Steel Mounting Arm, Concrete Poles P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N AMAW / SMAW AEL Catalog Number Nominal Arm Length (ft.) Dimensions (in.) A B C Weight (lbs.) (Max per Arm) EPA ft2 w/ 1.3 Gust up to 100mph Max Weight per Arm (lbs.) 76 AMAC T14 US4 AMAC T20 US4 AMAC T20 US6 AMAC T20 US8 4 4 6 8 42 42 66 90 18 18 24 30 10 10 12 15 6 8 11 14 2 276 2 276 SMAC T14 US4 SMAC T14 US6 SMAC T14 US8 SMAC T20 US4 SMAC T20 US6 SMAC T20 US8 4 6 8 4 6 8 42 66 90 42 18 24 30 18 66 30 10 12 15 10 24 15 13 17 21 18 12 30 2 276 2 2 24 2 90 IMPORTANT: 76 76 76 76 276 76 CAUTION: • These specifications are intended for general purposes only. American Electric Lighting reserves the right to change material or design without prior notice in a continuing effort to upgrade its products. • The arms described herein are designed for applications in areas of normal winds. Consult the factory prior to the design of systems to be mounted on structures such as bridges or buildings, or areas known to have abnormal winds such as airports or coastal areas. Failure to consider these factors in the system design could result in the failure of the pole or mast arm, and consequently in personal injury or property damage. A Keyhole .687" x 1.5" C B .375" GND Hole 1/4" x 2" HRS. Flat BAR (A36) or 3.8" x 2" Aluminum Flat Bar (6063) Slot .687" x 1.0" Product Guide 253 SMAWL Mounting Arm Steel Mounting Arm, Wall Mount P R O D U C T O V E R V I E W / O R D E R I N G Intended Use I N F O R M AT I O N Finish galvanized steel is standard. Optional polyester powder paint finishes available. Wall-mounting roadway fixtures Hardware not included. Features Construction: Body is galvanized steel tube (per ASTM A-123) constructed from A500 Grade B steel. Welding follows AWS standards. Arms are galvanized after fabrication. Example: S M A W L T 2 0 U S 4 G A L V A E L Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option SMAWL Pipe Size Series SMAWL T14 T20 1 - 2/3” O.C. (1 - 1/4” NPS) 2 - 3/8” O.D. (2” NPS) US2-5 US4 US6 US8 Arm Length (feet) Options 2-1/2'arm length 4'arm length 6' arm length1 8' arm length1 Standard Finish GALV Galvanized steel (standard w/ SMAW) Architectural Colors (powder finish)2 Standard Colors DDB Dark bronze DWH White DBL Black Notes: 1 2 254 Not available with AMAWT14. Other colors available, please contact your local American Electric Lighting representative. Product Guide For more information, please visit our website, www.americanelectriclighting.com SMAWL Mounting Arm Steel Mounting Arm, Wall Mount P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N AMAW / SMAW AEL Catalog Number Nominal Arm Length (ft.) SMAWL T14 US2-5 SMAWL T14 US4 SMAWL T14 US6 SMAWL T20 US2-5 SMAWL T20 US4 SMAWL T20 US6 SMAWL T20 US8 2’6" 4' 6' 2'6" 4' 6' 8' Dimensions (inches) A B C 30 42 66 30 42 15 19 24 15 19 66 30 10 10 12 10 10 24 15 90 Weight (pounds) (Max per arm) EPA ft2 w/ 1.3 gust up to 100mph Max Weight per arm (lbs) 11 13 18 17 22 12 38 2 2 2 2 2 30 2 76 76 76 76 76 276 76 IMPORTANT: CAUTION: • These specifications are intended for general purposes only. American Electric Lighting reserves the right to change material or design without prior notice in a continuing effort to upgrade its products. • The arms described herein are designed for applications in areas of normal winds. Consult the factory prior to the design of systems to be mounted on structures such as bridges or buildings, or areas known to have abnormal winds such as airports or coastal areas. Failure to consider these factors in the system design could result in the failure of the pole or mast arm, and consequently in personal injury or property damage. .562 Diameter (4 PLCS.) A 1" C 1" 1/4" Plate 14" 12" B 1/4" x 2" Flat Bar 2" 4" Product Guide 255 Options & Accessories Mast Arms & Brackets - Upsweep Arms (For Horizontally Mounted Luminaires) P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N Wood Pole Mounting Catalog Number 91-2401 A 92-2401 B 92-3001 C 92-3001 92-4801 92-4801 A 92-4802 92-4802 B 92-7201 C 92-7202 92-7202 92-9602 92-7201 A 92-2401 92-7202 B C 94-9601 93-9602 256 Product Guide Item 2' ARM -11/4 '' Aluminum, (Use with Nema Head only) Dimensions: A-24'', B-123/4'', C-73/8'' 2' ARM -11/4'' Steel, Class E Dimensions: A-24'', B-123/4'', C- 73/8'' 21/2' ARM -11/4'' Aluminum, (Use with NEMA head only) Dimensions: A-27'', B-123/4'', C-73/8'' 21/2' ARM -11/4'' Steel, Class E Dimensions: A-27'', B-123/4'', C-73/8'' 4' ARM -11/4'' Aluminum, Class B Dimensions: A-43'', B-213/4'', C-87/8'' 4' ARM -11/4'' Steel, Class E Dimensions: A-43'', B-211/2'', C-85/8'' 4' ARM -2'' Aluminum, Class D Dimensions: A-43'', B-211/4'', C-85/8'' 4' ARM -2'' Steel, Class E Dimensions: A-43'', B-211/2'', C-87/8'' 6' ARM -11/4'' Steel, Class C Dimensions: A-661/4'', B-291/2'', C-83/8'' 6' ARM -2'' Aluminum, Class B Dimensions: A-661/4'', B-291/2'', C-83/8'' 6' ARM -2'' Steel, Class D Dimensions: A-661/4'', B-291/2'', C-83/4'' 8' ARM -2'' Steel, Class D Dimensions: A-901/4'', B-297/8'', C-81/2'' 6' ARM -11/4'' Aluminum, Class B Dimensions: A-661/4'', B-291/2'', C-83/4'' 6' ARM -11/4'' Steel, Class E Dimensions: A-661/4'', B-291/2'', C-83/4'' 6' ARM -2'' Aluminum, Class D Dimensions: A-661/4'', B-29'', C-77/8'' 8' ARM -11/4'' Steel, Class C Dimensions: A-901/4'', B-291/2'', C-83/4'' 8' ARM -2'' Aluminum, Class B Dimensions: A-901/4'', B-291/2'', C-77/8'' For more information, please visit our website, www.americanelectriclighting.com Approx. Wt. (lbs.) 1-3/4 5-1/2 2 6 3-3/4 10 6-1/2 17-1/2 17-1/2 9 25-1/2 40 6-3/4 18 11 26-1/2 13-1/2 Options & Accessories Mast Arms & Brackets - Upsweep Arms (For Horizontally Mounted Luminaires) P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N Concrete Pole Mounting Catalog Number Item 90-2001 90-4801 D B C 20” ARM -1¼'' Steel, Class E Dimensions: A-20'', B-15'', C-12'' 4' ARM -1¼'' Steel, Class E Dimensions: A-48'', B-25'', C-12'' 6' ARM -2'' Steel, Class D Dimensions: A-72'', B-34'', C-12'' 8' ARM -2'' Steel, Class D Dimensions: A-96'', B-34'', C-12'' Mounting Bracket 90-7202 90-9602 A Approx. Wt. (lbs.) 10 16 29 48 Notes: 1. CLASS CHART — Denotes the maximum size luminaire recommended for use. Both weight and projected area must be considered. Classifications based on American Electric Lighting standards. See Isotach Wind Map, page 215. Luminaire Class Weight (in pounds) Effective Projected Area A 30 1.5 B 40 2.0 C 60 3.0 D 80 4.0 E 100 5.0 2. Steel mast arms constructed in accordance with ASTM specification A-36. 3. For more information, please contact your local American Electric Lighting representative. CAUTION: • The poles and mast arms described herein are designed for ground mounted applications in areas of normal winds. Consult the factory prior to the design of systems to be mounted on structures such as bridges or buildings, or areas known to have abnormal winds such as airports or coastal areas. Failure to consider these factors in the system design could result in the failure of the pole or mast arm, and consequently personal injury or property damage. Product Guide 257 258 Product Guide American Electric Lighting TM FREQUENTLY ORDERED PRODUCTS ROADWAY LIGHTING Roadway Series 125 TM DuraStar Series 20 20 10S RN 120 R3 FG 20 15S RN 120 R3 FG TM DuraStar Series 30 30 25S CA MT1 R2 FG 30 40S CA MT1 R3 FG LC PC 125 25S CA MT1 R3 DG 125 40M CA MT1 R3 DG 125 40S CA MT1 R3 DG Roadway Series 125 Cutoff 125 25S CA MT1 R3 FG 125 40S CA MT1 R3 FG 125 25S MR 120 R3 FG Roadway Series 325 Roadway Series 115 115 10S RN 120 R2 DA 115 15S RH 120 R2 DA 115 25S CA MT1 R3 DG 325 40M CA MT1 R3 DG 325 40S CA MT1 R3 DG Roadway Series 115 Cutoff 115 10S RN 120 R3 FG 115 10S CA MT1 R2 FG LC PC 115 15S MR 120 R3 FG 4B Roadway Series 325 Cutoff 325 25S CA MT1 R3 FG LC PC 325 25S MR DT1 R3 FG Roadway Series 315 Roadway Series 327 315 25S CA MT1 R2 DG 4B 315 10S XH MT2 R3 DA 4B Roadway Series 315 Cutoff 315 15S RH 120 R3 FG 315 10S CA MT1 R2 FG LC PC 327 X1M CA MT1 R3 DG 327 X1M CA 480 R3 DG Roadway Series 413 413 10S RN 120 R3 FG Product Guide 259 American Electric Lighting TM FREQUENTLY ORDERED PRODUCTS Multi-Mount TM Series 285 285 40S CA MT1 R3 DA GY UnderPass Series 581/681 581 25M CA MT1 LC 681 10S RN 120 LC Heavy-Duty Wall Pack Series 882 InterState TM II Series 775 775 40S CA MT1 R3 FG 882 40M CA MT1 LC Signlite Series 875 LPS Roadway Series SRP SRP 13L XH DT1 R4 DA LC PC 875 40M CA MT1 66 FG LC DECORATIVE AND POST-TOP LIGHTING LPS Roadway Series SRX SRX 55L XH DT1 R4 DP LC LPS Roadway Series SP2 SP2 09L XH DT1 R4 DP LC PC SP2 13L XH DT1 R4 DP LC PC SP2 18L XH DT1 R4 DP LC PC UnderPass Series GST GST 55L XH DT1 R1 DP LC 260 Product Guide Heritage Collection Marietta Series LMD LMD 10S CA MT1 R3 PA PR US LMD 17M CA MT1 R3 PA PR US LMD 10S CA MT1 R5 PA PR US LMD 17M CA MT1 R5 PA PR US Heritage Collection Sumter Series LSH LSH 10S CA MT1 R5 PA PR LSH 17M CA MT1 R5 PA PR Heritage Collection Cresthill Classic Series LCR LCR 10S CA MT1 R0 AP PR LCR 17M CA MT1 R0 AP PR LCR 17M CA MT1 R3 AP PR LCR 10S CA MT1 R5 AP PR For photometric information, visit our website, www.americanelectriclighting.com American Electric Lighting TM FREQUENTLY ORDERED PRODUCTS Heritage Collection Cresthill Sphere Series LCR LCR 10S CA MT1 R0 SY PR LCR 15S CA MT1 R0 SY PR LCR 17M CA MT1 R0 SY PR Heritage Collection Yorktown Series LYT LYT 10S RN 120 R5 PY BC LYT 15S RN 120 R5 PY BC LYT 17M CA MT1 R5 PY BC Heritage Collection Cresthill Centennial Series LCR LCR 10S CA MT1 R5 CW PR LCR 15S CA MT1 R5 CW PR LCR 17M CA MT1 R5 CW PR Heritage Collection Branson Series LBR LBR 10S CA MT1 R3 AY PR LBR 15S CA MT1 R3 AY PR Heritage Collection Cresthill Glass Series LCR LCR 10S CA MT1 R3 PG PR LCR 17M CA MT1 R3 PG PR LCR 17M CA MT1 R5 PG PR Heritage Collection Depot Series LDP LDP 15S RN 120 R0 PY BC Heritage Collection Lexington Series LLX LLX 10S CA MT1 R5 PY PR LLX 17M CA MT1 R5 PY PR American Revolution Series 247 247 10S RN 120 R3 AY 247 10S RN 120 R5 AY 247 15S RN 120 R3 AY 247 17V XN 120 R3 AY Heritage Collection Syracuse Series LSY LSY 10S CA MT1 R5 PY PR LSY 17M CA MT1 R5 PY PR Contempo Series 245 Heritage Collection Victorian Series LVI LVI 10S RN 120 R3 PY PR LVI 17M CA MT1 R3 PY PR Residential Post Series RES RES 07S RN 120 R5 PY 245 10S RN 120 R5 AY 245 15S RN 120 R5 AY 245 17V XN 120 R5 AY Product Guide 261 American Electric Lighting TM FREQUENTLY ORDERED PRODUCTS Series 110 TwistPack Series TWT TWT 10S RN 120 R5 AY H4 LC PC TWT 17M CA MT1 R5 AY H8 NR LC 110 10S RN 120 R1 110 15S RN 120 R1 110 17V XN 120 R1 Dusk to Dawn Series DTD Bainbridge Series 870 870 17M CA MT1 R5 AY LC BC 870 10S RN 120 R5 AY LC BC SECURITY LIGHTING DTD 25V CA 120 R5 BA CS LC NL PC DTD 40V CA 120 R5 BA CS LC NL PC Series 165 315 Series 165 20S XN 120 R5 BA PJ0 LC 165 40V XN 120 R5 BG LC LC 315 07S CA MT1 R5 BA EC PK 315 10S CA MT1 R5 BA EC PK 315 15S CA MT1 R5 BA EC PK 315 17M CA MT1 R5 BA PK 315 17V CA MT1 R5 BA PK AREA LIGHTING AVL NEMA Head Series 11 AVL X1M CA MT1 SM DG P2 A4 TL AVL 40M CA MT1 SM DG P2 A4 TL 11 10S RN 120 RO LO 11 10S RN 120 R5 BA 11 17V XN 120 RO LO 11 17V XN 120 R5 BA NEMA Head Package Series 11 PKG 11PKG 10S RN 120 R5 BA DPC EC 11PKG 15S RN 120 R5 BA DPC EC 11PKG 17V XN 120 R5 BA DPC LuxMaster® Luminaire 53 Series 11 “L” Package LuxMaster® Luminaire 153 53 15S CA MT1 R2 FG 53 15S RN 120 R2 FG 11L 10S RN 120 R5 BA 11L 15S RN 120 R5 BA 11L 17V XN 120 R5 BA 11L 17V RN 240 R5 BA 262 Product Guide For photometric information, visit our website, www.americanelectriclighting.com 153 25S CA MT1 R3 FG 153 40S CA MT1 R3 FG 153 40M CA MT1 R3 FG American Electric Lighting TM FREQUENTLY ORDERED PRODUCTS LuxMaster® Classic Series LS LS 10S CA 120 R3 NR LS 10S R3 HSG NR LMP BZ UltraFlood™ Series 75 LuxMaster® Classic Series LM LM 40M CA MT1 R3 NR LM 40M R3 HSG NR LMP BZ UltraFlood™ Series 77 LuxMaster® Classic Series LL LL X1M CA MT1 R3 NR LL XIM R3 HSG NR LMP BZ Quartz Flood Series 570 LuxMaster® Luminaire LML LML 18L XH MTI R1 FP Quartz Flood Series 474 FLOODLIGHTING AmeriSport™ Series ASP 75 25S CA MT1 76 0443 75 40M CA MT1 76 0443 75 40M CA MT1 66 0443 75 40S CA MT1 76 0443 77 X1M CA MT1 76 0443 77 X1M CA MT1 76 0443 TL NL 77 X1S CA MT1 65 0443 570 61/L 474-61/L-240V 474-61/L-277V ASP X5M CA MT1 GM 0343 ASP X5M CA MT1 GW 0343 Compact Flood Series 51 51 10S RH 120 77 TB 0643 NL TL 51 17M CA MT1 76 TB NL TL 51 20S CA 120 76 TB OP 0643 NL TL 51 40S CA MT1 76 TB OP 0643 NL TL Sportslighting Series SPF SPF X5M CA MT1 44 0343 SPF X5M CA MT1 55 0343 SPF X5M CA MT1 66 0343 Product Guide 263 American Electric Lighting TM FREQUENTLY ORDERED PRODUCTS DARK TO LIGHT PHOTOCONTROLS DUX Series Basic, UL Listed DUX124-12A J50 DE Series Filtered Silicon DE124-1.0-TM J50 DE480-1.5-TJ J50 DE120-1.5-TJ J50 DBE Series Button DD Series Diagnostic DD124-1.5-TMA J50 DBE120-1.5-T J25 DBE240-1.5-T J25 DB Series Button DPN Series Part Night® DPN124-2.6-TMGN J50 DP Series Silicon DP120-1.5-TM J50 DP120-1.5-TMBK J50 DP124-1.5-TJ J50 DP124-1.5-1704 J50 D Series Cadmium Sulphide D120-1.0-STM J50 D214-1.5-STM J50 DB120-1.5-ST J25 D779 Series, Industry Standard D7790 J12 D7790 J50 Shorting Caps DX Series Basic DX120-12A J50 DX124-12A J50 264 Product Guide For photometric information, visit our website, www.americanelectriclighting.com D-SHORT-SBK J12 ACCESSORIES, TECHNICAL DATA, TERMS & CONDITIONS HPS Replacement Starters...................................266 Lamp Selection .......................................................267 Fuse Ratings ....................................................268-273 Luminaire Classification Systems........................274 Floodlighting Applications. ...................................275 Floodlighting Calculations.....................................276 Location/Aiming Guidelines..................................276 Roadway Lighting Calculations............................277 Terms & Conditions ........................................278-279 Index .................................................................280-281 Product Guide 265 Accessories H P S R E P L A C E M E N T S TA R T E R S Catalog Number Description IGN 3L 36 OB 50/150 3 Lead 3/16” Terminal Open Board 55V IGN 3L 36 OB 200/400 3 Lead 3/16” Terminal Open Board 100V IGN 3L 14 OP 50/150 3 Lead 1/4” Terminal Open Plug 55V IGN 3L 14 OP 200/400 3 Lead 1/4” Terminal Open Plug 100V IGN 3L 14 EC 50/150 3 Lead 1/4” Terminal Encapsulated 55V IGN 3L 14 EC 200/400 3 Lead 1/4” Terminal Encapsulated 100V IGN 2L 36 OB 50/150 2 Lead 3/16” Terminal Open Board 55V IGN 2L 36 OB 200/400 2 Lead 3/16” Terminal Open Board 100V IGN 2L 14 OP 50/150 2 Lead 1/4” Terminal Open Plug 55V IGN 2L 14 OP 200/400 2 Lead 1/4” Terminal Open Plug 100V IGN 2L 14 EC 50/150 2 Lead 1/4” Terminal Encapsulated 55V IGN 2L 14 EC 200/400 2 Lead 1/4” Terminal Encapsulated 100V IGN 2L 36 OB DUAL 50/400 IGN 2L 14 OP DUAL 50/400 2 Lead 3/16” Terminal Open Board Dual 55/100V1 2 Lead 1/4” Terminal Open Plug Dual 55/100V1 IGN 2L 14 EC DUAL 50/400 2 Lead 1/4” Terminal Encapsulated Dual 55/100V1 IGN 2L 14 EC DUAL UNI 2 Lead 1/4” Terminal Encapsulated Dual Universal IGN 2L 14 OP DUAL UNI 2 Lead 1/4” Terminal Open Plug Dual Universal Notes: 1 266 Product Guide Ships as 55V, converts to 100V by removing jumper wire Applications & Design L A M P S E L E C T I O N Typical Lamp Types with Watts, Initial Lamp Lumens and Light Loss Factors Lamp Comparison Quartz Incandescent Mercury Vapor Low Pressure Sodium Metal Halide High Pressure Sodium Efficiency Poor 20 LPW Fair 56 LPW Best 183 LPW Good 100 LPW Better 125 LPW Mean Life Low 2K Hrs High 24K Hrs Medium 18K Hrs High 20K Hrs High 24K Hrs Lumen Maintenance High 97% Poor 57% High 100%(+9) Medium 80% High 90% Color Good Poor Good Poor Monochrome Excellent Acceptable System C.U. Good Good Fair Good Good Hot Restart Instant 10 Minutes 1 Minute 15 Minutes 1 Minute Warm-Up Instant 10 Minutes 10 Minutes 10 Minutes 5 Minutes System Cost Lowest Medium High High High Lamp Type High Pressure Sodium Metal Halide Recommended Minimum Mounting Heights for Various Lamps High Pressure Sodium Lamp 50W 70W 100W 150W 200W 250W 310W 400W 1000W Mercury Vapor Lamp Metal Halide Lamp 100W 175W 175W 400W 400W 1000W 1000W Minimum Mounting Height (ft.) 8.0 12.0 15.0 18.0 20.0 25.0 30.0 35.0 40.0 Maintenance Factors If maintained footcandle level is desired, multiply the area coverage per fixture by the maintenance factor. Maintenance factor is determined by multiplying the lamp lumen depreciation factor (LLD) by the luminaire dirt depreciation factor (LDD). The lamp lumen depreciation factor usually is the mean lumen value of the lamp. The luminaire dirt depreciation factor range is described in the Illuminating Engineering Society Handbook. A .9 dirt factor commonly is used. Mercury Vapor Pulse Start Metal Halide High Pressure Sodium with Internal Ignitor Watts Initial Lumens Mean Lumens Avg. Life 35 50 70 100 150 200 250 310 400 1000 2250 4000 6300 9500 16000 22000 28500 37000 50000 125000 2025 3600 5670 8550 14400 19800 25600 33300 45000 112000 24000 24000 24000 24000 24000 24000 24000 24000 24000 24000 50 70 100 150 175 250 400 1000 15000 3750 6000 9000 13500 13500 20500 36000 110000 165000 2800 4800 7200 9450 8775 13500 24000 71000 132000 15000 15000 15000 9000 10000 10000 20000 120000 3000 175 175 400 700 1000 16000 12100 21000 43000 57500 7400 10500 18900 33600 48400 24000 24000 24000 24000 24000 175 250 320 350 400 1000 16000 23800 31700 3700 44000 120000 112000 16600 23140 28000 31000 96000 150000 15000 15000 20000 20000 20000 3600 5400 8550 14400 19800 25600 33000 45000 126000 28500 28500 28500 28500 28500 28500 28500 28500 28500 50 70 100 150 200 250 310 400 1000 4000 6000 9500 16000 22000 28500 37000 50000 140000 Product Guide 267 Accessories F U S E R AT I N G S Nominal Lamp Wattage 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10V 10V 10V 10V Ballast Circuit Supply Voltage Input Watts RN RH XN XN XN XH XH XH CA CA CA CA CA CT CT CT MR MR MR RN RH XN XN XN XH XH XH CA CA CA CA CA CA CT CT CT MR MR MR XN XH CT CT 120 120 208 240 277 208 240 277 120 208 240 277 480 120 208 240 120 240 480 120 120 208 240 277 208 240 277 120 208 240 277 347 480 120 208 240 120 240 480 120 120 120 240 86 86 91 91 91 91 91 91 95 95 95 95 95 95 95 95 103 103 103 115 115 130 130 130 130 130 130 138 138 138 138 138 138 130 130 130 138 138 138 125 125 125 125 Current (amps) 2.10 1.30 1.53 1.35 1.17 0.85 0.75 0.65 0.90 0.53 0.48 0.43 0.23 0.86 0.50 0.43 0.90 0.45 0.23 3.05 1.80 2.25 1.98 1.53 1.25 1.10 0.85 1.18 0.70 0.60 0.50 0.40 0.29 1.22 0.70 0.61 1.20 0.60 0.30 3.60 2.00 1.05 0.52 Notes: 1 268 Product Guide Based on $.10/KWH; 12 months operation # of Fuses 1 1 2 2 1 2 2 1 1 2 2 1 2 1 2 2 1 2 2 1 1 2 2 1 2 2 1 1 2 2 1 1 2 1 2 2 1 2 2 1 1 1 2 Annual Fuse Rating (amps) 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 10 5 10 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 10 5 5 5 Energy Consumption ($)1 $37.67 $37.67 $39.86 $39.86 $39.86 $39.86 $39.86 $39.86 $41.61 $41.61 $41.61 $41.61 $41.61 $41.61 $41.61 $41.61 $45.11 $45.11 $45.11 $50.37 $50.37 $56.94 $56.94 $56.94 $56.94 $56.94 $56.94 $60.44 $60.44 $60.44 $60.44 $60.44 $60.44 $56.94 $56.94 $56.94 $60.44 $60.44 $60.44 $54.75 $54.75 $54.75 $54.75 Accessories F U S E Nominal Lamp Wattage 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 17V 17V 17V 17V 17V 17V 17V 17V 17V 17V 17V 17V 17M 17M 17M 17M 17M 17M 17M 17M 17M 17M 17M 17M Ballast Circuit Supply Voltage Input Watts RN RH XN XN XN XH XH XH CA CA CA CA CA CT CT CT CT MR MR MR RN RH RN RH XN XH CA CA CA CA CA CA CA CA CA CA CA CA SC SC SC SC SC SC 120 120 208 240 277 208 240 277 120 208 240 277 480 120 208 240 277 120 240 480 240 240 277 277 120 120 120 208 240 277 347 480 120 208 240 277 347 480 120 208 240 277 347 480 170 170 188 188 188 188 188 188 190 190 190 190 188 190 190 190 190 196 196 196 195 195 195 195 200 200 213 213 213 213 213 213 213 213 213 213 213 213 208 208 208 208 208 206 Current (amps) 4.50 2.35 2.88 2.52 2.25 1.60 1.40 1.25 1.65 0.95 0.82 0.72 0.42 1.76 1.01 0.88 0.76 1.70 0.90 0.40 2.70 1.50 2.34 1.17 6.00 3.33 1.80 1.10 0.90 0.78 0.62 0.51 1.80 1.10 0.90 0.78 0.62 0.51 1.80 1.05 0.90 0.80 0.65 0.45 # of Fuses 1 1 2 2 1 2 2 1 1 2 2 1 2 1 2 2 1 1 2 2 2 2 1 1 1 1 1 2 2 1 1 2 1 2 2 1 1 2 1 2 2 1 1 2 Annual Fuse Rating (amps) 15 10 10 10 10 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 10 5 10 5 15 10 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 R AT I N G S Energy Consumption ($)1 $74.46 $74.46 $82.34 $82.34 $82.34 $82.34 $82.34 $82.34 $83.22 $83.22 $83.22 $83.22 $82.34 $83.22 $83.22 $83.22 $83.22 $85.85 $85.85 $85.85 $85.41 $85.41 $85.41 $85.41 $87.60 $87.60 $93.29 $93.29 $93.29 $93.29 $93.29 $93.29 $93.29 $93.29 $93.29 $93.29 $93.29 $93.29 $91.10 $91.10 $91.10 $91.10 $91.10 $90.23 Notes: 1 Based on $.10/KWH; 12 months operation Product Guide 269 Accessories F U S E R AT I N G S Nominal Lamp Wattage 20S 20S 20S 20S 20S 20S 20S 20S 20S 20S 20S 20S 20S 20S 20S 20S 20S 20S 20M 20M 20M 20M 20M 20M 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S Ballast Circuit Supply Voltage Input Watts XN XH RN RH CA CA CA CA CA CA CT CT CT CT CT MR MR MR SC SC SC SC SC SC XN XH RN RH CA CA CA CA CA CA CT CT CT CT CT CT MR MR 120 120 240 240 120 208 240 277 347 480 120 208 240 277 480 120 240 480 120 208 240 277 347 480 120 120 240 240 120 208 240 277 347 480 120 208 240 277 347 480 120 240 240 240 218 218 240 240 240 240 240 240 235 235 235 235 235 255 255 255 232 232 232 232 232 232 287 287 282 282 295 295 295 295 295 310 300 300 300 300 300 300 310 310 Current (amps) 6.27 3.48 2.80 1.56 2.22 1.28 1.11 0.96 0.77 0.56 2.10 1.21 1.05 0.91 0.52 2.20 1.10 0.55 2.00 1.20 1.00 0.85 0.70 0.50 8.73 4.85 4.00 2.22 2.50 1.50 1.30 1.10 0.93 0.63 2.75 1.60 1.38 1.19 0.92 0.69 2.80 1.40 Notes: 1 270 Product Guide Based on $.10/KWH; 12 months operation # of Fuses 1 1 2 2 1 2 2 1 1 2 1 2 2 1 2 1 2 2 1 2 2 1 1 2 1 1 2 2 1 2 2 1 1 2 1 2 2 1 1 2 1 2 Annual Fuse Rating (amps) 20 10 10 5 10 5 5 5 5 5 10 5 5 5 5 10 5 5 5 5 5 5 5 5 30 15 10 10 10 5 5 5 5 5 10 5 5 5 5 5 10 5 Energy Consumption ($)1 $105.12 $105.12 $95.48 $95.48 $105.12 $105.12 $105.12 $105.12 $105.12 $105.12 $102.93 $102.93 $102.93 $102.93 $102.93 $111.69 $111.69 $111.69 $101.62 $101.62 $101.62 $101.62 $101.62 $101.62 $125.71 $125.71 $123.52 $123.52 $129.21 $129.21 $129.21 $129.21 $129.21 $135.78 $131.40 $131.40 $131.40 $131.40 $131.40 $131.40 $135.78 $135.78 Accessories F U S E Nominal Lamp Wattage 25S 25V 25V 25V 25V 25V 25V 25V 25V 25V 25V 25V 25V 25V 25M 25M 25M 25M 25M 25M 25M 25M 25M 25M 25M 25M 25M 31S 31S 31S 31S 31S 31S 31S 31S 32M 32M 32M 32M 32M 32M 40S Ballast Circuit Supply Voltage Input Watts MR RN RH XN XH CA CA CA CA CA CA CT CT CT CA CA CA CA CA CA CT CT CT SC SC SC SC CA CA CA CA CA MR MR MR SC SC SC SC SC SC RN 480 240 240 120 120 120 208 240 277 347 480 120 240 480 120 208 240 277 347 480 120 240 480 120 208 240 277 120 208 240 277 480 120 240 480 120 208 240 277 347 480 208 310 274 274 285 285 298 298 298 298 295 295 295 295 295 298 298 298 298 295 295 295 295 295 291 291 291 291 365 365 365 365 365 380 380 380 368 368 368 368 368 368 440 Current (amps) 0.70 3.00 1.67 6.85 3.81 2.50 1.45 1.25 1.10 0.90 0.63 2.66 1.54 1.33 2.50 1.45 1.25 1.10 0.90 0.63 2.66 1.54 1.33 2.50 1.45 1.25 1.10 3.37 1.94 1.68 1.45 0.84 3.30 1.65 0.83 3.25 1.90 1.65 1.40 1.10 0.80 5.20 # of Fuses 2 2 2 1 1 1 2 2 1 1 2 1 2 2 1 2 2 1 1 2 1 2 2 1 2 2 1 1 2 2 1 2 1 2 2 1 2 2 1 1 2 2 Annual Fuse Rating (amps) 5 10 5 20 10 10 5 5 5 5 5 10 5 5 10 5 5 5 5 5 10 5 5 10 5 5 5 10 5 5 5 5 10 5 5 10 5 5 5 5 5 15 R AT I N G S Energy Consumption ($)1 $135.78 $120.01 $120.01 $124.83 $124.83 $130.52 $130.52 $130.52 $130.52 $129.21 $129.21 $129.21 $129.21 $129.21 $130.52 $130.52 $130.52 $130.52 $129.21 $129.21 $129.21 $129.21 $129.21 $127.46 $127.46 $127.46 $127.46 $159.87 $159.87 $159.87 $159.87 $159.87 $166.44 $166.44 $166.44 $161.18 $161.18 $161.18 $161.18 $161.18 $161.18 $192.72 Notes: 1 Based on $.10/KWH; 12 months operation Product Guide 271 Accessories F U S E R AT I N G S Nominal Lamp Wattage 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40V 40V 40V 40V 40V 40V 40V 40V 40V 40V 40V 40V 40V 40V 40M 40M 40M 40M 40M 40M 40M 40M 40M 40M Ballast Circuit Supply Voltage Input Watts RH RN RH XN XH CA CA CA CA CA CA CT CT CT CT CT CT MR MR MR XN XH CA CA CA CA CA CA CT CT CT CT CT CT CA CA CA CA CA CA CT CT CT CT 208 240 240 120 120 120 208 240 277 347 480 120 208 240 277 347 480 120 240 480 120 120 120 208 240 277 347 480 120 208 240 277 347 480 120 208 240 277 347 480 120 208 240 277 440 440 440 463 463 464 464 464 464 464 464 465 465 465 465 465 465 490 490 490 440 440 458 458 458 458 460 462 465 465 465 465 462 465 458 458 458 458 460 462 465 465 465 465 Current (amps) 2.89 6.00 3.33 6.70 3.72 3.80 2.20 1.90 1.70 1.32 0.97 4.20 2.40 2.10 1.82 1.45 1.05 4.20 2.10 1.05 17.00 9.44 4.00 2.30 2.00 1.75 1.40 1.00 4.00 2.31 2.00 0.87 1.35 1.00 4.00 2.30 2.00 1.75 1.40 1.00 4.00 2.31 2.00 0.87 Notes: 1 272 Product Guide Based on $.10/KWH; 12 months operation # of Fuses 2 2 2 1 1 1 2 2 1 1 2 1 2 2 1 1 2 1 2 2 1 1 1 2 2 1 1 2 1 2 2 1 1 2 1 2 2 1 1 2 1 2 2 1 Annual Fuse Rating (amps) 10 15 10 20 10 10 10 5 5 5 5 15 10 10 5 5 5 15 10 5 N/A 30 10 10 5 5 5 5 10 10 5 5 5 5 10 10 5 5 5 5 10 10 5 5 Energy Consumption ($)1 $192.72 $192.72 $192.72 $202.79 $202.79 $203.23 $203.23 $203.23 $203.23 $203.23 $203.23 $203.67 $203.67 $203.67 $203.67 $203.67 $203.67 $214.62 $214.62 $214.62 $192.72 $192.72 $200.60 $200.60 $200.60 $200.60 $201.48 $202.36 $203.67 $203.67 $203.67 $203.67 $202.36 $203.67 $200.60 $200.60 $200.60 $200.60 $201.48 $202.36 $203.67 $203.67 $203.67 $203.67 Accessories F U S E Nominal Lamp Wattage 40M 40M 40M 40M 40M 40M 75S 75S 75S 75M 75M 75M 75M 75M 75M 75M X1S X1S X1S X1S X1S X1S X1M X1M X1M X1M X1M X1M X1M X1M X1M X1M X1M X1M X5M X5M X5M X5M X5M X5M Ballast Circuit Supply Voltage Input Watts CT CT SC SC SC SC CA CA CA CA CA CA CA SC SC SC CA CA CA CA CA CA CA CA CA CA CA CA SC SC SC SC SC SC CA CA CA CA CA CA 347 480 120 208 240 277 120 208 240 820 820 820 820 120 208 240 120 208 240 277 347 480 120 208 240 277 347 480 120 208 240 277 347 480 120 208 240 277 347 480 462 465 452 452 452 452 840 840 840 120 208 240 277 812 812 812 1100 1100 1100 1100 1100 1100 1070 1070 1070 1070 1070 1080 1080 1080 1080 1080 1080 1070 1605 1605 1605 1605 1615 1625 Current (amps) 1.35 1.00 3.80 2.20 1.90 1.65 6.75 4.00 3.50 6.90 3.85 3.45 3.00 7.00 4.00 3.50 9.50 5.50 4.75 4.15 3.30 2.30 9.00 5.20 4.50 3.90 3.20 2.25 9.00 5.20 4.50 3.90 3.20 2.25 13.50 7.80 6.75 5.58 4.80 3.40 # of Fuses 1 2 1 2 2 1 1 2 2 1 2 2 1 1 2 2 1 2 2 1 1 2 1 2 2 1 1 2 1 2 2 1 1 2 1 2 2 1 1 2 Annual Fuse Rating (amps) 5 5 10 10 5 5 20 10 10 20 10 10 10 20 10 10 30 15 15 15 10 10 30 15 15 10 10 10 30 15 15 10 10 10 N/A 20 20 15 15 10 R AT I N G S Energy Consumption ($)1 $202.36 $203.67 $197.98 $197.98 $197.98 $197.98 $367.92 $367.92 $367.92 $52.56 $91.10 $105.12 $121.33 $355.66 $355.66 $355.66 $481.80 $481.80 $481.80 $481.80 $481.80 $481.80 $156.222 $156.222 $156.222 $156.222 $156.222 $157.682 $157.682 $157.682 $157.682 $157.682 $157.682 $156.222 $234.332 $234.332 $234.332 $234.332 $235.792 $237.252 Notes: 1 2 Based on $.10/KWH; 12 months operation Based on $.10/KWH; 4 months operation Product Guide 273 Applications & Design L U M I N A I R E C L A S S I F I C AT I O N WIDTH CLASSIFICATION Mounted at Pavement Type I Center Type II Edge Normally Used for: S Y S T E M S TYPE I Roadways up to 2 times the mounting height in width Up to 1 times the mounting height for one side mounting Up to 2 times the mounting height for both side mounting Type III Edge Up to 1.5 times the mounting height for one side mounting Up to 3 times the mounting height for both side mounting Type IV Edge Up to 2 times the mounting height for one side mounting Up to 4 times the mounting height for both side mounting Type V Center Up to 4 times the mounting height in total width TYPE I - 4 Way TYPE II TYPE II - 4 Way 274 SPACING CLASSIFICATION Definition S Short M Medium Spacings up to 5 times mounting height L Long Spacings up to 5 times mounting height GLARE CONTROL CLASSIFICATION Definition CO Cutoff SCO Semi-Cutoff Medium control of light above 80 Vertical NCO Non-Cutoff No control requirements above 80 Vertical FCO Full-Cutoff Strict control of light above 80 Vertical Zero emission above 90 Vertical Product Guide Normally Used for: Spacings up to 4 times the mounting height Normally Used for: TYPE III TYPE IV Strict control of light above 80 Vertical 2.5% emission above 90 Vertical TYPE V Applications & Design Floodlighting A P P L I C AT I O N S IES Classifications Setback The IES beam spreads indicate the angular ranges (horizontally and vertically) through which the intensity of the floodlight is greater than 10% of its maximum intensity. This angular range is referred to as the 'Field Angle'. For example: Asymmetrical beam spread 138° (H) x 119° (V) HORIZONTAL The recommended setback is three-fourth the building height. If a building is 30 feet tall, the recommended setback is 22.5 feet from the building. Locating the floodlight closer to the building will sacrifice uniformity; setting it farther back will result in a loss of efficiency. Setback distance = 3/4 x building height 3/4 (30 ft.) = 22.5 ft. Setback IES Beamspread Classification IES Type 10° up to 18° 18° up to 29° 29° up to 46° 46° up to 70° 70° up to 100° 100° up to 130° 130° and up 1 2 3 4 5 6 7 Sign Lighting Considerations: 1. Setback 2. Spacing 3. Aiming VERTICAL = IES 7 X 6 Field Angle Degrees Sign Lighting When lighting a sign with ground-mounted floodlights, there are three considerations: setback, spacing and aiming. Beam Description very narrow narrow medium narrow medium medium wide wide very wide Spacing The rule of thumb for spacing floodlights is not to exceed two times the setback distance. If the setback is 22.5 feet, the floodlights should not be placed more than 45 feet apart. When using ground-mounted floodlights to light a sign, the recommended setback is a distance equal to three-fourths the sign height. For example, the setback distance for a 12-foot by 6-foot sign would be 4.5 feet. Locating the floodlight closer will sacrifice uniformity while setting it farther back will result in a loss of efficiency. Setback distance = 3/4 x sign height 3/4 (6 ft.) = 4.5 ft. Spacing = 2 x setback distance 22.5 ft. x 2 = 45 ft. apart The IES classification was formerly referred to as NEMA Type. The following outdoor design tips provide general guidelines for lighting design. These guidelines may not apply to all applications. Spacing GROUND-MOUNTED FLOODLIGHTS Ground-mounted floodlights are used to light building facades, signs and flagpoles. Facade Lighting When lighting building facades with groundmounted floodlights, three factors are considered: setback, spacing and aiming. Facade Lighting Considerations: 1. Setback 2. Spacing 3. Aiming Aiming The floodlight should be aimed at least twothirds the height of the building. For example, if a building is 30 feet high, the recommended aiming point is approximately 20 feet high. After installation is complete, aiming can be adjusted to produce the best appearance. Mounting a full or upper visor to the floodlight can reduce unwanted spill light. The rule of thumb for spacing floodlights is not to exceed two times the setback distance. If the setback is 4.5 feet, the floodlights should not be placed more than 9 feet apart. Spacing = 2 x setback distance 4.5 ft. x 2 = 9 ft. apart Aiming point = 2/3 x building height 2/3 (30 ft.) = 20 ft. high Product Guide 275 Applications & Design Floodlighting L O C AT I O N / A I M I N G G U I D E L I N E S Spacing Spacing Ideally, three floodlights are recommended to light a flag. The floodlights should be placed approximately 120° apart. When more than one pole is added, pole placement is a concern. The "4 times" rule of thumb for spacing indicates that a pole should be placed four times the mounting height from the adjacent poles. If a flood is mounted on a 20-foot pole, space the poles 80 feet apart. Aiming The floodlight should be aimed at least twothirds up the sign. For example, if a sign is six feet tall, then the floodlight will be aimed approximately four feet high. After installation is completed, aiming can be adjusted to produce the best appearance. Mounting a full or upper visor to the floodlight can reduce unwanted glare. 3 floodlights spaced 120° apart Pole spacing = 4 x mounting height 4 (20-ft. pole) = 80 feet between poles Aiming point = 2/3 x sign height 2/3 (6 ft.) = 4 ft. high 80' 40' Aiming The recommended aiming point for each floodlight is the center of the flag or the top of the pole. Mounting a full or upper visor to the floodlight can reduce unwanted spill light. Flag Lighting Ground-mounted floodlights also can be used to light flags. Setback, spacing and aiming must all be considered. Setback The recommended setback for lighting a flag is one-third times the pole height. If the pole is 30 feet tall, the floodlight should be set back a distance of 10 feet away from the pole. 80' 160' 120° Flag Lighting Considerations: 1. Setback 2. Spacing 3. Aiming 40' 120° 120° 20' Vertical Aiming A single floodlight uses the two-thirds rule of thumb for vertical aiming. The fixture is aimed 2/3 of the distance across the area to be lighted and at least 30° below horizontal. If the area to be lighted is 40 feet across, the recommended aiming point is 27 feet. Aiming point = 2/3 across distance to be lighted 2/3 (40 ft.) = 27 ft. aiming point aim at least 30˚ to avoid glare POLE-MOUNTED FLOODLIGHTS General Area Lighting Pole-mounted floodlights commonly are used for general area lighting applications such as parking lots and storage yards. Mounting height, spacing, vertical aiming and horizontal aiming should be considered. General Lighting Considerations: 1. Mtg. Height 2. Spacing 3. Vertical aiming 4. Horizontal aiming Setback distance = 1/3 x pole height 1/3 (30 ft.) = 10 ft. 27' 13' 40' Additionally, to minimize glare, the recommended aiming point distance should never exceed twice the mounting height. If a pole is 20 feet high, the vertical aiming point should not exceed 40 feet out. 2 (20 ft. mounting height) = 40 ft. Horizontal Aiming Mounting Height Mounting height = 1/2 distance to be lighted 1/2 (40 ft.) = 20 ft. GL IN AIM 20' 276 Product Guide INE AIM IN G 10' The recommended mounting height is one half the distance across the area to be lighted. If the area to be lighted is 40 feet across, the lowest recommended mounting height is 20 feet. LIN E 30' When an additional floodlight is added to a single pole, horizontal aiming also must be considered. First, each floodlight should be vertically aimed according to the two-thirds rule. As long as the floodlight has a horizontal NEMA 6 or 7 beamspread, the floodlights can be aimed up to 90° apart. 90˚ 40' AIMING POINT Applications & Design Roadway Lighting C A L C U L AT I O N S American Electric Lighting offers an extensive line of luminaires for your roadway lighting applications. The calculations which follow will help you determine the type, quantity and placement of these luminaires. Refer to the data provided in the INTRODUCTION to the APPLICATIONS & DESIGN section of this catalog. You also will need data from the Photometric Test Report for the luminaire(s) being considered. Contact your American Electric Lighting representative for these reports. A sample report is provided for your use in the following calculations. Calculations Initial Lamp Coefficient of Light Loss Lumens x Utilization x Factor Average Maintained = Footcandles Pole Spacing Pole Spacing x Road Width Initial Lamp Coefficient of Light Loss Lumens x Utilization x Factor = Average Maintained Footcandles x Initial Lamp Lumens Averaged Maintained Footcandles = Coefficient Utilization Pole Spacing x x Road Width x Road Width Light Loss Factor SAMPLE CALCULATIONS A roadway is to be lighted to a level of 1fc (Average Maintained Footcandles). The roadway is 45 feet wide and the poles are 30 feet high, therefore, the mounting height ratio is 1.5 The Photometric Test Report provides: Initial Lamp Lumens = 14,000. Coefficient of Utilization (at 1.5MHR) = 43% for the 175W MH lamp used in an American Electric Lighting LuxMaster® luminaire. The light loss factor provided in the preceding charts for the 175W MH lamp is 0.70. Initial lamp lumens also are provided in this chart. Pole Spacing = 14,000 (ILL) x .43 (CU) x .70 (LLF) = 94 Feet (PS) 1 (AMF) x 45 (RW) If pole spacing is known, then average maintained footcandles can be calculated: Average Maintained Footcandles = 14,000 (ILL) x .43 (CU) x .70 (LLF) = .996 (AMF) 94 (PS) x 45 (RW) Or initial lamp lumens can be calculated: Initial Lamp Lumens = 1 (AMF) x 94 (PS) x 45 (RW) = 14,000 (ILL) .43 (CU) x .70 (LLF) Other application data may be determined by similar calculations. Contact your local American Electric Lighting representative for assistance. AMF - Average Maintained Footcandles CU - Coefficient of Utilization ILL - Initial Lamp Lumens MHR - Mounting Height Ratio LLF - Light Loss Factor PS - Pole Spacing RW - Road Width Product Guide 277 TERMS AND CONDITIONS OF SALE For Shipments Within the United States* Effective February 1, 2006 TERMS: All American Electric Lighting products — 1% cash discount will be allowed on invoices paid by the 10th of the month following the month of billing. Payments made after the 10th are due on a net basis to the 25th (1% 10th prox, net 25th prox). FREIGHT ALLOWANCE: Products from American Electric Lighting may be combined on an order to qualify for freight allowance. Shipments are F.O.B. our plants, Distribution Centers or Field Warehouses: ● ● All factory orders having a distributor price of $2,000 or more for one consignee for one release qualify for freight allowed. Warehouse orders of stock items having a distributor price of $2,000 or more for one consignee for one release qualify for freight allowed. ● All orders having a distributor price of less than $2,000 will be assessed freight and handling charges. ● Anchor bolts are included with American Electric Lighting poles. Pre-shipped anchor bolts having a distributor price of less than $2,000 will be assessed freight and handling charges. ALL SHIPMENTS — On orders qualifying for freight allowance, we reserve the right to route at our discretion. We will ship in the manner selected by the customer provided the customer assumes any additional transportation costs. TRANSPORTATION CLAIMS: Our equipment is tested for mechanical defects prior to shipping. Our packaging is regularly inspected by transportation authorities who assume responsibility for both apparent and concealed damages sustained by improper handling. Title passes to purchaser upon delivery by us to the carrier, and all claims for damages or shortages in transit shall be made by purchaser with delivering carrier. We shall be glad to assist when called upon provided notification is given in writing within 15 days of receipt of shipment. PACKAGING: The company reserves the right to alter the quantities of any order so as to conform to standard packaging. PRICES: Prices are subject to change without notice. In the event of price increases, all orders on hand will be filled at lower prices provided such orders are released for shipping prior to the price increase. If the orders are not released for shipment prior to the price increase, the orders will be billed at prices in effect at the time of shipment. Special quoted orders which cannot be released for shipping prior to the price increase may be subject to an increase in price. Minimum billing is $100 net. Prices do not include lamps unless so specified. Orders for parts totaling less than $15 will be billed $15 lump sum. 278 designated on the return authorization. Credit will be issued based on the original invoice price, or price in effect at time of return, whichever is lower, less a restocking charge of 25% minimum (to partially defray our cost of handling), less reconditioning and replacing costs if necessary, and less the freight expense of the original shipment. The reconditioning charge will be determined by the repair, refinishing or reconditioning required to restore the merchandise to a saleable condition. All nonstocking, special, custom-made or outdated, and modified versions of normal factory stocking items are not returnable. Authorization will not be granted when value of all items to be returned is less than $100. Return from any one job will be limited to not more than 10% of the total job value. SERVICE AREA LIMITATION: The company reserves the right to refuse to make quotations, accept orders or make shipments to points of destination outside of the regular or assigned selling and service area of the distributor. GUARANTEE: American Electric Lighting warrants all equipment to be free from defect in manufacturing, under normal and proper storage, installation, and use, for a period of one (1) year. In addition we provide a Six (6) year warranty on the factory installed electrical system (consisting of ballast, ignitor, capacitor, lamp socket, terminal board, PEC receptacle, and wiring) inside AEL products. Our guarantee liability extends only to the repair or replacement of the defective part and no labor charges for correction of the defect by repair or replacement will be honored by American Electric Lighting unless prior written authority has been granted by our Customer Service Department. CANCELLATION CHARGE: Orders for stocking items may be cancelled prior to shipping without charge. All other orders may not be cancelled unless we are reimbursed for work already performed and for special material purchased by our company. If an order is cancelled after shipment or if delivery is refused at destination, all warehousing, delivery and return costs will be charged to the customer. GENERAL: Possession of a price sheet does not entitle one to purchase. Specifications are subject to change without notice. Consult factory for verification. The compliance of our product to individual project specifications and the approval for their use is not warranted by our company. ACCEPTANCE: Acceptance of orders can be made only at our plants, Distribution Centers or Field Warehouses for warehouse orders on the basis of these terms and conditions of sale. Acceptance of orders is limited to the terms and conditions hereof. American Electric Lighting hereby objects to additional or different terms offered by purchaser in its sales order or any other document of purchaser. Such additional or different terms shall not become a part of any order without the express written consent of American Electric Lighting. RETURN MERCHANDISE: American Electric Lighting reserves the right to change these Terms and Conditions of Sale without notice. No merchandise may be returned without prior written authorization from our factories. Requests to return merchandise must be made with our agents for transmittal to the factory within four (4) months from date of shipment by us. All returns must be shipped prepaid to the location * For shipments outside the United States, contact factory for applicable Terms and Conditions of Sale. Product Guide TERMS AND CONDITIONS OF SALE For Shipments Within Canada* Effective September 1, 2004 TERMS: DROP SHIPMENTS: All American Electric Lighting Canada products payment terms are 2%10 or Net 30 days. 2%-10 days means that: All invoices dated from the first to the 15th of the month are payable on the 25th of the same month. All invoices from the 15th to the 30th of the month are payable on the 10th of the following month. Alternatively, all invoices are due Net 30 days following invoice date. The company reserves the right to refuse to make direct shipments to points of destination outside of the regular or assigned selling and service area of the distributor. FREIGHT ALLOWANCE: Shipments are F.O.B. our plants, Lachine, Quebec, and St. Hyacinthe, Quebec, and our Canadian Field Warehouses. Warehouse or Factory orders must equal $2,000.00 DSP or more for shipment to one consignee for one release to qualify for freight allowance. All orders having a distributor price of less than $2,000.00 will be assessed freight and handling charges. Special customer shipping requirements that cause additional shipping expenses above normal may be charged for the additional cost. TRANSPORTATION CLAIMS: Our equipment is tested for malfunctions and defects prior to shipping. Our packaging is regularly inspected by transportation authorities who assume responsibility for both apparent and concealed damages sustained by improper handling. Title passes to purchaser upon delivery by us to carrier, and all claims for damages or shortages in transit shall be made by purchaser with delivering carrier. We shall be glad to assist when called upon, provided notification is given in writing within 15 days of receipt of shipment. GUARANTEE: American Electric Lighting warrants all equipment to be free from defect in manufacturing, under normal and proper storage, installation, and use, for a period of one (1) year. In addition we provide a Six (6) year warranty on the factory installed electrical system (consisting of ballast, ignitor, capacitor, lamp socket, terminal board, PEC receptacle, and wiring) inside AEL products. Our guarantee liability extends only to the repair or replacement of the defective part and no labor charges for correction of the defect by repair or replacement will be honored by American Electric Lighting unless prior written authority has been granted by our Customer Service Department. CANCELLATION CHARGES: Orders for stocking items may be cancelled prior to shipping without charge. All other orders may not be cancelled unless we are reimbursed for work already performed and for special material purchased by our company. If an order is cancelled after shipment or if delivery is refused at destination, all warehousing, delivery, and return costs will be charged to the customer. GENERAL: The company reserves the right to alter quantities of any order so as to conform to standard packaging, except for job site requirements. Possession of a price sheet does not entitle one to purchase. Specifications are subject to change without notice. Consult factory for verification. The compliance of our product to individual project specifications and the approval for their use is not warranted by our company. PRICES: ACCEPTANCE: Prices are subject to change without notice. In the event of price increases, all orders on hand will be filled at lower prices provided such orders are released from shipping prior to the price increase. If the orders are not released for shipment prior to the price increase, the orders will be billed at prices in effect at the time of the shipment. Minimum billing is $100 net. Prices do not include lamps unless so specified. Prices exclude all taxes. Orders for parts totaling less than $50 will automatically be billed $50. Acceptance of orders can only be made at our plant as noted in the FREIGHT ALLOWANCE section or at Field Warehouses for warehouse orders on the basis of the terms and conditions of sale printed on our current distributor price sheet, acknowledgments and invoices. PACKAGING: RETURN MERCHANDISE: American Electric Lighting Canada reserves the right to change these Terms and Conditions of Sale without notice. * For shipments outside Canada, contact factory for applicable Terms and Conditions of Sale. No merchandise may be returned without prior written authorization from our factories. Requests to return merchandise must be made with our agents for transmittal to the factory within four (4) months from date of shipment by us. All returns must be shipped prepaid to the location designated on the return authorization. Credit will be issued based on the original invoice price, or price in effect at time of return, whichever is lower, less a restocking charge of 25% minimum (to partially defray our cost of handling), less reconditioning and replacing costs if necessary, and less the freight expense of the original shipment. The reconditioning charge will be determined by the repair, refinishing or reconditioning required to restore the merchandise to a saleable condition. All non-stocking, special, custom-made or outdated, and modified versions of normal factory stocking items are not returnable. Authorization will be granted on $100 minimum value only. Product Guide 279 Index 315 Series ...........................................................................140 Floodlighting Accessories................................................192 Floodlighting Ballast Matrices.........................................197 Aluminum Pole Mounting Brackets ...............................229 AMAC / SMAC ....................................................................252 AMAW / SMAW .................................................................250 American Revolution Series 247........................................86 American Revolution Cutoff Series 247............................88 AmeriSport™ Series ASP ................................................188 ANSI Color Chart................................................................212 Area Accessories ..............................................................172 Area Ballast Matrices .......................................................176 AVL .......................................................................................158 Bainbridge Series 870 ........................................................96 Ballast Matrices Roadway ........................................................................54 Decorative Post Top ...................................................132 Security ........................................................................155 Area ..............................................................................176 Floodlighting ................................................................197 Compact Flood Series 51..................................................180 Contempo Series 245 ..........................................................90 D Series...............................................................................204 D779 Series .........................................................................210 DA Series.............................................................................209 DB Series.............................................................................208 DBE Series ..........................................................................207 DD Series.............................................................................201 DE Series .............................................................................200 Decorative Post Top Ballast Matrices............................132 DP Series.............................................................................203 DPN Series..........................................................................202 DuraStar™ Series 20 ...........................................................10 DuraStar™ Series 30 ...........................................................12 Dusk To Dawn Series DTD................................................150 DUX Series ..........................................................................206 DX Series.............................................................................205 280 Product Guide Georgian Series GRP ..........................................................98 Heavy-Duty Wallpack 882 ..................................................48 Heritage Collection ..............................................................62 Cresthill Classic ............................................................66 Cresthill Sphere ............................................................68 Branson ..........................................................................82 Cresthill Centennial ......................................................70 Cresthill Glass ...............................................................72 Depot ..............................................................................84 Lexington........................................................................74 Marietta Series .............................................................62 Sumter Series................................................................64 Syracuse Series............................................................76 Victorian Series.............................................................78 Yorktown.........................................................................80 Heritage Poles ....................................................................100 Accessories.................................................................108 Chadsworth Series.....................................................100 New Albany Series.....................................................102 Statesboro Series.......................................................104 Waycross Series.........................................................106 InterState II 775...................................................................36 LPS Roadway - SP2.............................................................42 LPS Roadway - SRP.............................................................38 LPS Roadway - SRX.............................................................40 LuxMaster® Classic Series LL ........................................168 LuxMaster® Classic Series LM ......................................166 LuxMaster® Classic Series LS........................................164 LuxMaster® LPS Luminaire Series LML........................170 LuxMaster® Luminaire Series 153 .................................162 LuxMaster® Luminaire Series 53 ...................................160 Multi-Mount™ 285 ..............................................................34 Index NEMA Head 11...................................................................142 Security Accessories .......................................................154 NEMA Head Package Series 11 PKG .............................144 Security Ballast Matrices.................................................155 Series 11 "L" Package ........................................................146 Series 110 ............................................................................148 Series 165 ............................................................................152 Shorting Caps .....................................................................211 SignLite 875 ...........................................................................50 SMAWL................................................................................254 Sportslighting Series SPF ................................................190 SPRTC ..................................................................................237 SPRTS ..................................................................................241 SSA.......................................................................................221 SSAH ....................................................................................222 SSF .......................................................................................233 SSS .......................................................................................225 STC .......................................................................................236 Steel Pole Mounting Brackets.........................................230 STS .......................................................................................226 STSH.....................................................................................227 Photocontrol Accessories ...............................................212 Photocontrol Recommendation Chart ............................212 Pole Options & Accessories ....................................228, 256 Pole Technical Data Florida Wind Rating....................................................216 General Information ...................................................217 Illustrated Samples ....................................................214 Wind Map ....................................................................215 Quartz Flood Series 570....................................................186 Residential Post Top Series RES.......................................92 Roadway 115 ........................................................................14 Roadway 115 Cutoff .............................................................16 Roadway 125 ........................................................................22 Roadway 125 Cutoff .............................................................24 Roadway 315 ........................................................................18 Roadway 315 Cutoff .............................................................20 Roadway 325 ........................................................................26 Roadway 325 Cutoff .............................................................28 Roadway 327.........................................................................30 Roadway 413.........................................................................32 Roadway Accessories ........................................................52 Roadway Ballast Matrices .................................................54 RSA.......................................................................................218 RSAH ....................................................................................220 RSS .......................................................................................223 RTA .......................................................................................219 RTAU.....................................................................................244 RTCD.....................................................................................234 RTCDDB ...............................................................................235 RTF .......................................................................................231 RTFDB ..................................................................................232 RTS .......................................................................................224 RTSU.....................................................................................248 Technical Data Calculations .................................................................277 Floodlighting Aiming...................................................276 Flood Lights - Applications........................................275 Fuse Ratings ................................................................268 HPS Replacement Starters .......................................266 Lamp Selection ...........................................................267 Location/Aiming Guidelines......................................276 Luminaire Classification Systems............................274 Terms & Conditions............................................................278 TwistPack™ Series TWT ....................................................94 UltraFlood™ Series 75 .....................................................182 UltraFlood™ Series 77.......................................................184 Underpass 581/681...............................................................46 Underpass GST.....................................................................44 Product Guide 281 NOTES NOTES NOTES NOTES NOTES NOTES