Instrumentation Cables

advertisement
Instrumentation Cables
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
300V – PVC Insulated, PVC Jacketed ITC Rated
Applications and Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overall Shielded Pairs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overall Shielded Triads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Individual and Overall Shielded Pairs . . . . . . . . . . . . . . . . . . . . . . .
Individual and Overall Shielded Triads . . . . . . . . . . . . . . . . . . . . . .
3
4
5
6
7
600V – PVC/Nylon Insulated, PVC Jacketed TC Rated
Applications and Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Overall Shielded Pairs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Overall Shielded Triads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Individual and Overall Shielded Pairs . . . . . . . . . . . . . . . . . . . . . . 11
Individual and Overall Shielded Triads . . . . . . . . . . . . . . . . . . . . . 12
Technical Information
Electrical Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Belden Cross-Reference by Part Number . . . . . . . . . . . . . . . . . . 14-15
Belden Cross-Reference by Description . . . . . . . . . . . . . . . . . . . . 16-17
Product and Copper Conductor Data . . . . . . . . . . . . . . . . . . . . . . 18
Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
1-866-6-NEXANS
1
Introduction
Nexans is one of the largest wire
and cable manufacturers in the
world, and in North America. In
North America we manufacture in
locations across the United States
and Canada. We design and
produce a wide range of cables
used in power, industrial,
construction and communication
applications.
With more than nine decades of
experience as a leader in the
industrial and power cable markets,
Nexans is contracted by heavy
industry and utilities world wide to
provide turnkey solutions for the
bulk transmission of power – from
generating station through the
distribution system to commercial
and residential areas.
This catalogue has been prepared
for the convenience of those using
electrical conductors in industrial
applications.
It presents the important data
pertaining to the various types of
wires and cables in readily
obtainable form. We believe that
the information included in the
many tabulations will be of
particular value to the architect,
engineer, electrician, and layperson
alike.
Although we have listed herein the
types of wires and cables suitable
for most conditions, we are
equipped to manufacture other
types to suit special needs. We
would be pleased to recommend
the most suitable construction for
any special condition that you may
encounter.
The determination of the correct
cable size and type, and the
selection of methods of installation
suitable for the type and location of
particular circuits, should be made
in accordance with local
regulations. Any questions in this
respect should be directed primarily
to the local Electrical Inspection
Authority.
1-866-6-NEXANS
2
Instrumentation Cable
300V, PVC Insulated, 105°C
Unshielded Pairs or Triads with Overall Shield
Shielded Pairs or Triads with Overall Shield
Type PLTC – UL 13 – NEC ART 725
Type ITC – UL 2250 – NEC ART 727
Applications
Pairs: black/white and number coded
Triads: black/white/red and number
coded
• As indicated in UL 13 and 2250: The
overall jackets of these cables are a
“gas/vapour tight continuous sheath”
as discussed in NEC Sections
501.5(D) and 501.5(E).*
• For use under raised floors in control
rooms when arranged in such a
fashion as to prevent damage to the
cables.
• In Class 2 and Class 3 Circuits, as
defined in NEC ART 725 for Type
PLTC cables.
Bending Radius
Options
Insulation: polyvinyl chloride in
accordance with UL 13 and UL 2250,
flame retardant, 105°C temperature
rating.
Fixed Position: 5 x cable overall
diameter
During Installation: 8 x cable
overall diameter
Insulation Shield (on shielded pair/
triad constructions): aluminum foil/
polyester shield helically wrapped to
provide 100% coverage with a tinned
copper drain wire that is two gauge
sizes smaller than the circuit
conductors.
Specifications
The following constructions can be
provided on special orders:
• Tinned copper conductors
• When increased mechanical,
chemical, or environmental
protection is required, cables can be
supplied with a continuously
corrugated aluminum armor and an
outer PVC jacket.
• Interlocked aluminum armor with or
without an outer PVC jacket.
• Direct Burial listed cable (when
ordered as ITC/DB)
• Conductors with alternate color /
identification codes
• Alternate jacket colors
The 300V Instrumentation Cables are
dual listed as Type PLTC per UL 13 and
Type ITC per UL 2250. These cables
are suitable for installations as outlined
in NEC ART 725 for Type PLTC cables
and NEC ART 727 for Type ITC cables.
Construction
Conductor: bare, annealed copper
conforming to ASTM B-3 and Class B
stranded in accordance to ASTM B-8.
Assembly: pairs/triads are cabled in
concentric layers. In the case of
unshielded pairs/triads, they are
cabled at staggered lengths to reduce
crosstalk.
Overall cable shield: aluminum
foil/polyester shield helically wrapped
to provide 100% coverage with a
tinned copper drain wire that is the
same size as the circuit conductors,
with the exception of single pair/triad
constructions where the drain wire is
two gauge sizes smaller than the circuit
conductors.
Jacket: UL listed sunlight and
moisture resistant, sequentially length
marked, black, flame retardant
polyvinyl chloride material. A Nylon
ripcord is included for ease of jacket
removal.
Conductor Identification
• Conductor rated 105°C 300V
• Meets UL requirements for Type PLTC
and ITC
• Designated Type PLTC per NEC ART
725
• Designated Type ITC per NEC ART
727
Product Features
• UL approved Type PLTC and ITC,
300V
• UL approved insulated conductors
• Cables pass UL 1685 and IEEE 383
vertical fire tests at 70,000 BTU/hr
• Temperature rating 105°C dry
• Sunlight and moisture resistant jacket
• For use within Class 1 Division 2 and
Class 2 Division 2 Hazardous
Locations, and Intrinsically Safe
applications as permitted by NEC
ART 392, 501, 502, 504 and 505.*
1-866-6-NEXANS
3
* Use in hazardous locations:
Please note that no investigation of
these cables has been performed
regarding the transmission of gases or
vapours through the core. When these
cables are used in hazardous locations
they should be sealed properly as
required by the NEC.
Instrumentation Cable
300V, PVC Insulated, 105°C, Overall Shield
UL 13 – Type PLTC – NEC ART 725
UL 2250 – Type ITC – NEC ART 727
Unshielded Pairs with an Overall Shield (POS), 300V
Part
Number
# of
Pairs
Cond.
Size
AWG
Insulation
Thickness
mils
mm
Jacket
Thickness
mils
mm
Nominal Diameter Approximate Net
over Jacket
Cable Weight
inches
mm
lb/kft
kg/km
lb
kg
669606
————
671206
671219
————
671180
671305
676494
671313
671339
671347
1
2
4
8
10
12
16
20
24
36
50
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
12
12
12
12
12
12
12
12
12
12
12
.30
.30
.30
.30
.30
.30
.30
.30
.30
.30
.30
37
37
42
52
52
52
62
62
62
72
72
.94
.94
1.07
1.32
1.32
1.32
1.57
1.57
1.57
1.83
1.83
.212
.264
.353
.485
.529
.570
.662
.726
.783
.951
1.095
5.38
6.71
8.97
12.32
13.44
14.48
16.81
18.44
19.89
24.16
27.81
27
49
74
133
158
182
243
291
338
495
658
40
73
110
198
235
271
362
433
503
737
979
25
40
74
140
172
205
270
336
401
598
828
11
18
34
64
78
93
122
152
182
271
376
669614
669739
671123
669633
————
671115
676411
————
671107
671099
671065
1
2
4
8
10
12
16
20
24
36
50
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
15
15
15
15
15
15
15
15
15
15
15
.38
.38
.38
.38
.38
.38
.38
.38
.38
.38
.38
37
42
52
52
52
62
62
62
72
72
72
.94
1.07
1.32
1.32
1.32
1.57
1.57
1.57
1.83
1.83
1.83
.230
.302
.413
.541
.592
.659
.742
.851
.901
1.071
1.236
5.84
7.67
10.49
13.74
15.04
16.74
18.85
21.62
22.89
27.20
31.39
34
67
105
176
211
257
326
393
476
675
901
51
100
156
262
314
382
485
585
708
1005
1341
39
64
116
220
271
323
426
530
633
944
1306
18
29
53
100
123
147
193
240
287
428
592
669580
671156
671198
671164
————
671172
672220
————
671297
671131
671149
1
2
4
8
10
12
16
20
24
36
50
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
15
15
15
15
15
15
15
15
15
15
15
.38
.38
.38
.38
.38
.38
.38
.38
.38
.38
.38
37
42
52
62
62
62
62
72
72
72
82
.94
1.07
1.32
1.57
1.57
1.57
1.57
1.83
1.83
1.83
2.08
.254
.339
.464
.633
.693
.748
.844
.949
1.026
1.224
1.437
6.45
8.61
11.79
16.08
17.60
19.00
21.44
24.10
26.06
31.09
36.50
47
91
142
256
307
357
454
570
667
956
1314
70
135
211
381
457
531
676
848
993
1423
1955
62
103
268
350
433
516
681
846
1011
1507
2085
28
47
122
159
196
234
309
384
459
684
946
Note: Specifications and weights shown are nominal and subject to standard industry tolerances.
1-866-6-NEXANS
4
Pulling Tension
Instrumentation Cable
300V, PVC Insulated, 105°C, Overall Shield
UL 13 – Type PLTC – NEC ART 725
UL 2250 – Type ITC – NEC ART 727
Unshielded Triads with an Overall Shield (TOS), 300V
Part
Number
# of
Triads
Cond.
Size
AWG
Insulation
Thickness
mils
mm
Jacket
Thickness
mils
mm
Nominal Diameter Approximate Net
over Jacket
Cable Weight
inches
mm
lb/kft
kg/km
lb
kg
669747
————
————
————
————
————
————
————
————
————
————
1
2
4
8
10
12
16
20
24
36
50
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
12
12
12
12
12
12
12
12
12
12
12
.30
.30
.30
.30
.30
.30
.30
.30
.30
.30
.30
37
42
52
52
62
62
62
62
72
72
82
.94
1.07
1.32
1.32
1.57
1.57
1.57
1.57
1.83
1.83
2.08
.222
.357
.433
.556
.670
.690
.765
.849
.963
1.099
1.312
5.64
9.07
11.00
14.12
17.02
17.53
19.43
21.56
24.46
27.91
33.32
33
70
107
181
233
266
336
406
496
698
961
49
104
159
269
347
396
500
604
738
1039
1430
33
57
106
204
254
303
401
500
598
893
1238
15
26
48
93
115
137
182
227
271
405
562
669622
————
675256
675215
————
————
————
————
————
————
————
1
2
4
8
10
12
16
20
24
36
50
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
15
15
15
15
15
15
15
15
15
15
15
.38
.38
.38
.38
.38
.38
.38
.38
.38
.38
.38
37
52
52
62
62
62
62
72
72
72
82
.94
1.32
1.32
1.57
1.57
1.57
1.57
1.83
1.83
1.83
2.08
.242
.413
.476
.635
.741
.764
.849
.963
1.070
1.224
1.462
6.15
10.49
12.09
16.13
18.82
19.41
21.56
24.46
27.18
31.09
37.13
42
96
141
254
311
358
454
571
674
958
1321
63
143
210
378
463
533
676
850
1003
1426
1966
51
90
168
323
401
478
633
789
944
1410
1953
23
41
76
147
182
217
287
358
428
640
886
669598
————
687907
671321
————
————
688093
————
————
————
————
1
2
4
8
10
12
16
20
24
36
50
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
15
15
15
15
15
15
15
15
15
15
15
.38
.38
.38
.38
.38
.38
.38
.38
.38
.38
.38
37
52
52
62
62
62
72
72
72
82
92
.94
1.32
1.32
1.57
1.57
1.57
1.83
1.83
1.83
2.08
2.34
.267
.460
.533
.713
.836
.863
.981
1.089
1.212
1.410
1.681
6.78
11.68
13.54
18.11
21.23
21.92
24.92
27.66
30.78
35.81
42.70
58
126
192
352
432
500
661
807
954
1396
1923
86
188
286
524
643
744
984
1201
1420
2077
2862
82
144
268
516
639
763
1011
1259
1507
2250
3117
37
65
122
234
290
346
459
571
684
1021
1414
Note: Specifications and weights shown are nominal and subject to standard industry tolerances.
1-866-6-NEXANS
5
Pulling Tension
Instrumentation Cable
300V, PVC Insulated, 105°C, Individual and Overall Shield
UL 13 – Type PLTC – NEC ART 725
UL 2250 – Type ITC – NEC ART 727
Shielded Pairs with an Overall Shield (SPOS), 300V
Part
Number
# of
Pairs
Cond.
Size
AWG
Insulation
Thickness
mils
mm
Jacket
Thickness
mils
mm
Nominal Diameter Approximate Net
over Jacket
Cable Weight
inches
mm
lb/kft
kg/km
lb
kg
669705
669820
669697
————
671263
671362
————
671370
671388
671396
2
4
8
10
12
16
20
24
36
50
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
12
12
12
12
12
12
12
12
12
12
.30
.30
.30
.30
.30
.30
.30
.30
.30
.30
42
52
52
62
62
62
62
72
72
82
1.07
1.32
1.32
1.57
1.57
1.57
1.57
1.83
1.83
2.08
.349
.423
.543
.654
.674
.747
.827
.939
1.071
1.278
8.86
10.74
13.79
16.61
17.12
18.97
21.01
23.85
27.20
32.46
66
101
170
220
250
316
382
466
655
902
98
150
253
327
372
470
568
693
975
1342
52
96
184
228
272
360
448
536
800
1108
24
44
83
103
123
163
203
243
363
503
669671
669689
669721
————
669713
671404
————
671412
671420
671081
2
4
8
10
12
16
20
24
36
50
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
15
15
15
15
15
15
15
15
15
15
.38
.38
.38
.38
.38
.38
.38
.38
.38
.38
52
52
62
62
62
62
72
72
72
82
1.32
1.32
1.57
1.57
1.57
1.57
1.83
1.83
1.83
2.08
.382
.443
.577
.720
.743
.824
.935
1.038
1.187
1.417
9.70
11.25
14.66
18.29
18.87
20.93
23.75
26.37
30.15
35.99
84
121
211
285
327
415
521
614
870
1201
125
180
314
424
487
618
775
914
1295
1787
81
149
285
353
421
558
694
830
1239
1716
37
68
129
160
191
253
315
376
562
778
671222
671230
671248
————
671255
671438
————
671446
671453
671487
2
4
8
10
12
16
20
24
36
50
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
15
15
15
15
15
15
15
15
15
15
.38
.38
.38
.38
.38
.38
.38
.38
.38
.38
52
52
62
62
62
72
72
72
82
82
1.32
1.32
1.57
1.57
1.57
1.83
1.83
1.83
2.08
2.08
.446
.516
.690
.808
.834
.948
1.053
1.171
1.362
1.603
11.33
13.11
17.53
20.52
21.18
24.08
26.75
29.74
34.59
40.72
120
174
317
388
449
592
721
852
1245
1684
179
259
472
577
668
881
1073
1268
1853
2506
129
237
454
537
671
888
1105
1322
1972
2731
59
108
206
244
304
403
501
600
894
1239
Note: Specifications and weights shown are nominal and subject to standard industry tolerances.
1-866-6-NEXANS
6
Pulling Tension
Instrumentation Cable
300V, PVC Insulated, 105°C, Individual and Overall Shield
UL 13 – Type PLTC – NEC ART 725
UL 2250 – Type ITC – NEC ART 727
Shielded Triads with an Overall Shield (STOS), 300V
Part
Number
# of
Triads
Cond.
Size
AWG
Insulation
Thickness
mils
mm
Jacket
Thickness
mils
mm
Nominal Diameter Approximate Net
over Jacket
Cable Weight
inches
mm
lb/kft
kg/km
lb
kg
————
693770
693788
————
693796
693804
————
————
————
————
2
4
8
10
12
16
20
24
36
50
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
20(7w)
12
12
12
12
12
12
12
12
12
12
.30
.30
.30
.30
.30
.30
.30
.30
.30
.30
42
52
52
62
62
62
62
72
72
82
1.07
1.32
1.32
1.57
1.57
1.57
1.57
1.83
1.83
2.08
.357
.433
.556
.670
.690
.765
.849
.963
1.099
1.275
9.07
11.00
14.12
17.02
17.53
19.43
21.56
24.46
27.91
32.39
77
122
212
272
313
399
485
591
841
1155
115
182
315
405
466
594
722
880
1252
1719
68
128
249
310
370
491
612
732
1095
1518
31
58
113
141
168
223
278
332
497
689
————
669495
676403
————
671054
————
————
671040
669929
————
2
4
8
10
12
16
20
24
36
50
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
15
15
15
15
15
15
15
15
15
15
.38
.38
.38
.38
.38
.38
.38
.38
.38
.38
52
52
62
62
62
62
72
72
72
82
1.32
1.32
1.57
1.57
1.57
1.57
1.83
1.83
1.83
2.08
.431
.476
.635
.741
.764
.849
.963
1.070
1.224
1.420
10.95
12.09
16.13
18.82
19.41
21.56
24.46
27.18
31.09
36.07
108
160
293
360
416
533
671
793
1137
1565
161
238
436
536
619
793
999
1180
1692
2329
106
200
389
483
577
765
953
1141
1705
2363
48
91
176
219
262
347
432
518
773
1072
————
671271
671693
————
672063
————
————
631846
————
————
2
4
8
10
12
16
20
24
36
50
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
15
15
15
15
15
15
15
15
15
15
.38
.38
.38
.38
.38
.38
.38
.38
.38
.38
52
52
62
62
62
72
72
72
82
82
1.32
1.32
1.57
1.57
1.57
1.83
1.83
1.83
2.08
2.08
.460
.533
.713
.836
.863
.981
1.089
1.212
1.410
1.613
11.68
13.53
18.11
21.23
21.92
24.92
27.66
30.78
35.81
40.97
146
221
410
504
587
777
953
1130
1660
2252
217
329
610
750
874
1156
1418
1682
2470
3351
170
320
619
769
919
1218
1518
1817
2715
3764
77
145
281
349
417
552
689
824
1232
1707
Note: Specifications and weights shown are nominal and subject to standard industry tolerances.
1-866-6-NEXANS
7
Pulling Tension
Instrumentation Cable
600V, PVC/Nylon Insulated, 90°C
Unshielded Pairs or Triads with Overall Shield
Shielded Pairs or Triads with Overall Shield
Type TC – UL 1277 – NEC ART 336
Applications
Conductor Identification
The 600V Instrumentation Cables are
listed as Type TC per UL 1277. These
cables are suitable for installations as
outlined in NEC ART 336.
Pairs: black/white and number coded
Triads: black/white/red and number
coded
Construction
Conductor: bare, annealed copper
conforming to ASTM B-3 and Class B
stranded in accordance to ASTM B-8.
Insulation: PVC/Nylon Type TFN in
accordance with UL 62, flame
retardant, 90°C temperature rating.
Insulation Shield (on shielded pair/
triad constructions): aluminum foil/
polyester shield helically wrapped to
provide 100% coverage with a tinned
copper drain wire that is two gauge
sizes smaller than the circuit
conductors.
Assembly: pairs/triads are cabled in
concentric layers. In the case of
unshielded pairs/triads, they are
cabled at staggered lengths to reduce
crosstalk.
Overall cable shield: aluminum
foil/polyester shield helically wrapped
to provide 100% coverage with a
tinned copper drain wire that is the
same size as the circuit conductors,
with the exception of single pair/triad
constructions where the drain wire is
two gauge sizes smaller than the circuit
conductors.
Bending Radius
Fixed Position: 5 x cable overall
diameter
During Installation: 8 x cable
overall diameter
Specifications
• Meets UL 62, TFN rated 90°C 600V
conductors
• Meets UL requirements for Type TC
• Designated Type TC per NEC ART
336
Product Features
• UL approved Type TC, 600V
• UL approved insulated conductors
• Cables pass UL 1685 and IEEE 383
vertical fire tests at 70,000 BTU/hr
• Temperature rating 90°C dry, 75°C
wet
• Sunlight and moisture resistant jacket
• For use within Class 1 Division 2 and
Class 2 Division 2 Hazardous
Locations, and Intrinsically Safe
applications as permitted by NEC
ART 392, 501, 502, 504 and 505.*
• As indicated in UL 1277: The overall
jackets of these cables are a “gas/
vapour tight continuous sheath” as
discussed in NEC Sections 501.5(D)
and 501.5(E).*
Jacket: UL listed sunlight and moisture
resistant, sequentially length marked,
black, flame retardant polyvinyl
chloride material. A Nylon ripcord is
included for ease of jacket removal.
1-866-6-NEXANS
8
• Cables are rated for Direct Burial
applications
• For use in cable trays, raceways,
conduit or for aerial applications
where installed with a messenger
• Cables may be used In Class 1
Circuits, as defined in NEC Section
336.10 and ART 725 for Type TC
cables
• Cables may also be used as
permitted for nonpower-limited fire
alarm circuits as defined in NEC
Sections 336.10 and 760.27
• The Nylon jacket over the PVC
insulation provides excellent oil and
gasoline protection
Options
The following constructions can be
provided on special orders:
• Tinned copper conductors
• When increased mechanical,
chemical, or environmental
protection is required, cables can be
supplied with a continuously
corrugated aluminum armor and an
outer PVC jacket.
• Interlocked aluminum armor with or
without an additional outer PVC
jacket
• Conductors with alternate color/
identification codes
• Alternate jacket colors
* Use in hazardous locations:
Please note that no investigation of
these cables has been performed
regarding the transmission of gases or
vapours through the core. When these
cables are used in hazardous locations
they should be sealed properly as
required by the NEC.
Instrumentation Cable
600V, PVC/Nylon Insulated, 90°C
Overall Shield
UL 1277 – Type TC – NEC ART 336
Unshielded Pairs with an Overall Shield (POS), 600V
Part
Number
# of
Pairs
Cond.
Size
AWG
Insulation
Thickness
mils
mm
Jacket
Thickness
mils
mm
Nominal Diameter Approximate Net
over Jacket
Cable Weight
inches
mm
lb/kft
kg/km
lb
kg
669101
631275
631283
697490
627489
627208
697672
627208
————
697276
627190
631291
1
2
4
6
8
10
12
16
20
24
36
50
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
47
47
47
62
62
62
62
62
82
82
82
82
1.19
1.19
1.19
1.57
1.57
1.57
1.57
1.57
2.08
2.08
2.08
2.08
.270
.340
.442
.557
.617
.675
.728
.821
.943
1.018
1.209
1.396
6.86
8.64
11.23
14.15
15.67
17.15
18.49
20.85
23.95
25.86
30.71
35.46
42
77
114
162
208
248
286
361
469
544
765
1017
63
115
170
241
310
369
426
537
698
810
1138
1513
39
64
116
170
220
271
323
426
530
633
944
1306
18
29
53
77
100
123
147
193
240
287
428
592
697391
631242
631440
631457
————
631259
697474
669408
697482
627216
631267
1
2
4
8
10
12
16
20
24
36
50
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
47
47
47
62
62
62
82
82
82
82
82
1.19
1.19
1.19
1.57
1.57
1.57
2.08
2.08
2.08
2.08
2.08
.294
.377
.494
.690
.756
.817
.964
1.058
1.144
1.354
1.578
7.47
9.58
12.55
17.53
19.20
20.75
24.49
26.87
29.06
34.39
40.08
55
103
152
279
334
388
528
636
745
1057
1417
82
153
226
415
497
577
786
946
1109
1573
2109
62
103
268
350
433
516
681
846
1011
1507
2085
28
47
122
159
196
234
309
384
459
684
946
Note: Specifications and weights shown are nominal and subject to standard industry tolerances.
1-866-6-NEXANS
9
Pulling Tension
Instrumentation Cable
600V, PVC/Nylon Insulated, 90°C
Overall Shield
UL 1277 – Type TC – NEC ART 336
Unshielded Triads with an Overall Shield (TOS), 600V
Part
Number
# of
Triads
Cond.
Size
AWG
Insulation
Thickness
mils
mm
Jacket
Thickness
mils
mm
Nominal Diameter Approximate Net
over Jacket
Cable Weight
inches
mm
lb/kft
kg/km
lb
kg
669119
————
————
————
————
————
————
————
676676
————
————
1
2
4
8
10
12
16
20
24
36
50
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
47
47
47
62
62
82
82
82
82
82
82
1.19
1.19
1.19
1.57
1.57
2.08
2.08
2.08
2.08
2.08
2.08
.283
.442
.513
.700
.820
.886
.982
1.088
1.208
1.382
1.628
7.19
11.23
13.03
17.78
20.83
22.50
24.94
27.64
30.68
35.10
41.35
51
90
153
282
345
427
538
651
765
1080
1451
76
134
228
420
513
635
801
969
1138
1607
2159
51
90
168
323
401
478
633
789
944
1410
1953
23
41
76
147
182
217
287
358
428
640
886
697888
————
————
————
————
————
————
————
————
687228
————
1
2
4
8
10
12
16
20
24
36
50
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
47
47
62
62
82
82
82
82
82
82
112
1.19
1.19
1.57
1.57
2.08
2.08
2.08
2.08
2.08
2.08
2.84
.309
.490
.601
.779
.955
.985
1.094
1.214
1.351
1.549
1.887
7.85
12.45
15.27
19.79
24.26
25.02
27.79
30.84
34.32
39.34
47.93
68
120
222
383
503
578
735
893
1055
1505
2142
101
179
330
570
749
860
1094
1329
1570
2240
3188
82
144
268
516
639
763
1011
1259
1509
2250
3117
37
65
122
234
290
346
459
571
684
1021
1414
Note: Specifications and weights shown are nominal and subject to standard industry tolerances.
1-866-6-NEXANS
10
Pulling Tension
Instrumentation Cable
600V, PVC/Nylon Insulated, 90°C
Individual and Overall Shield
UL 1277 – Type TC – NEC ART 336
Shielded Pairs with an Overall Shield (SPOS), 600V
Part
Number
# of
Pairs
Cond.
Size
AWG
Insulation
Thickness
mils
mm
Jacket
Thickness
mils
mm
Nominal Diameter Approximate Net
over Jacket
Cable Weight
inches
mm
lb/kft
kg/km
lb
kg
631358
631366
631374
————
631382
697532
671735
697540
697557
627919
2
4
8
10
12
16
20
24
36
50
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
47
47
62
62
62
82
82
82
82
82
1.19
1.19
1.57
1.57
1.57
2.08
2.08
2.08
2.08
2.08
.429
.498
.678
.794
.819
.951
1.053
1.169
1.336
1.572
10.90
12.65
17.22
20.17
20.80
24.16
26.75
29.69
33.93
39.93
96
139
257
314
359
490
592
695
987
1314
143
207
382
467
534
729
881
1034
1469
1955
81
149
285
353
421
558
694
830
1239
1716
37
68
129
160
191
253
315
376
562
778
631309
631317
631325
631333
631341
————
697508
697516
680405
697524
680413
693564
2
3
4
6
8
10
12
16
20
24
36
50
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
47
47
62
62
62
82
82
82
82
82
92
112
1.19
1.19
1.57
1.57
1.57
2.08
2.08
2.08
2.08
2.08
2.34
2.84
.480
.514
.590
.694
.763
.937
.966
1.072
1.190
1.323
1.536
1.849
12.19
13.06
14.99
17.63
19.38
23.80
24.54
27.23
30.23
33.60
39.01
46.96
127
145
201
270
344
455
521
660
801
944
1370
1914
189
216
299
402
512
677
775
982
1192
1405
2039
2848
129
183
237
350
454
537
671
888
1105
1322
1972
2731
59
83
108
159
206
244
304
403
501
600
894
1239
Note: Specifications and weights shown are nominal and subject to standard industry tolerances.
1-866-6-NEXANS
11
Pulling Tension
Instrumentation Cable
600V, PVC/Nylon Insulated, 90°C
Individual and Overall Shield
UL 1277 – Type TC – NEC ART 336
Shielded Triads with an Overall Shield (STOS), 600V
Part
Number
# of
Triads
Cond.
Size
AWG
Insulation
Thickness
mils
mm
Jacket
Thickness
mils
mm
Nominal Diameter Approximate Net
over Jacket
Cable Weight
inches
mm
lb/kft
kg/km
lb
kg
689547
631408
631416
————
697565
————
————
631424
697565
————
2
4
8
10
12
16
20
24
36
50
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
18(7w)
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
47
62
62
82
82
82
82
82
82
112
1.19
1.57
1.57
2.08
2.08
2.08
2.08
2.08
2.08
2.84
.453
.557
.718
.882
.909
1.008
1.118
1.242
1.421
1.734
11.51
14.15
18.24
22.40
23.09
25.60
28.40
31.55
36.09
44.04
117
190
327
432
495
628
762
899
1279
1826
170
283
487
643
737
935
1134
1338
1903
2717
106
200
389
483
577
765
953
1141
1705
2363
48
91
176
219
262
347
432
518
773
1072
————
631390
627133
————
627141
688648
————
683029
————
————
2
4
8
10
12
16
20
24
36
50
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
16(7w)
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
15/4
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
.38/.10
47
62
62
82
82
82
82
82
82
112
1.19
1.57
1.57
2.08
2.08
2.08
2.08
2.08
2.08
2.84
.509
.624
.810
.993
1.024
1.138
1.265
1.408
1.615
1.967
12.93
15.85
20.57
25.22
26.01
28.91
32.13
35.76
41.02
49.96
156
253
444
581
671
858
1046
1238
1777
2523
232
377
661
865
999
1277
1557
1842
2644
3755
170
320
619
769
919
1218
1518
1817
2715
3764
77
145
281
349
417
552
689
824
1232
1707
Note: Specifications and weights shown are nominal and subject to standard industry tolerances.
1-866-6-NEXANS
12
Pulling Tension
Instrumentation Cable
Electrical Properties
300V – Unshielded Pairs/Triads with an Overall Cable Shield
Capacitance
Pairs
Conductor–
Conductor
(pf/ft)
Triads
Conductor Size
(AWG)
DC Resistance
(ohms/kft @ 20°C)
Conductor–
Shield
(pf/ft)
Conductor–
Conductor
(pf/ft)
Conductor–
Shield
(pf/ft)
20
10.50
48
95
51
102
18
6.64
49
98
52
104
16
4.18
53
107
56
112
300V – Shielded Pairs/Triads with an Overall Cable Shield
Capacitance
Pairs
Conductor–
Conductor
(pf/ft)
Triads
Conductor Size
(AWG)
DC Resistance
(ohms/kft @ 20°C)
Conductor–
Shield
(pf/ft)
Conductor–
Conductor
(pf/ft)
Conductor–
Shield
(pf/ft)
20
10.50
58
115
61
122
18
6.64
61
122
64
125
16
4.18
72
143
76
147
600V – Unshielded Pairs/Triads with an Overall Cable Shield
Capacitance
Pairs
Triads
Conductor Size
(AWG)
DC Resistance
(ohms/kft @ 20°C)
Conductor–
Conductor
(pf/ft)
Conductor–
Shield
(pf/ft)
Conductor–
Conductor
(pf/ft)
Conductor–
Shield
(pf/ft)
18
6.64
39
79
42
103
16
4.18
47
94
50
100
600V – Shielded Pairs/Triads with an Overall Cable Shield
Capacitance
Pairs
Triads
Conductor Size
(AWG)
DC Resistance
(ohms/kft @ 20°C)
Conductor–
Conductor
(pf/ft)
Conductor–
Shield
(pf/ft)
Conductor–
Conductor
(pf/ft)
Conductor–
Shield
(pf/ft)
18
6.64
74
148
78
156
16
4.18
86
172
90
180
1-866-6-NEXANS
13
Instrumentation Cable
Belden Cross-Reference by Part Number
Belden
Part
Number
Nexans
Part
Number
1030A
1031A
1032A
1033A
1034A
1035A
1036A
1037A
1038A
1039A
1040A
1041A
1042A
1043A
1044A
1045A
1046A
1047A
1048A
1049A
1050A
1051A
1052A
1053A
1054A
1055A
1056A
1057A
1058A
1059A
1060A
1061A
1062A
1063A
1064A
1065A
1066A
1067A
1068A
1069A
1070A
1071A
1072A
1073A
1074A
1075A
1076A
1077A
669580
669598
669614
669606
669937
669622
631317
627919
631325
631333
631341
697508
697516
680405
697524
680413
693564
631358
631366
631374
631382
697532
697540
697557
631309
671206
671219
671180
671305
671313
671339
671347
631275
631283
627489
697672
627208
697276
631242
631440
631457
631259
697474
697482
669705
669820
669697
Description
Belden
Part
Number
Nexans
Part
Number
1pr 16AWG OS 300V
1tr 16AWG OS 300V
1pr 18AWG OS 300V
1pr 20AWG OS 300V
1tr 16AWG NS 300V
1pr 16AWG NS 300V
1tr 18AWG OS 300V
3pr16AWG SPOS 600V
50pr18AWG SPOS 600V
4pr 16AWG SPOS 600V
6pr 16AWG SPOS 600V
8pr 16AWG SPOS 600V
12pr 16AWG SPOS 600V
16pr 16AWG SPOS 600V
20pr 16AWG SPOS 600V
24pr 16AWG SPOS 600V
36pr 16AWG SPOS 600V
50pr 16AWG SPOS 600V
2pr 18AWG SPOS 600V
4pr 18AWG SPOS 600V
8pr 18AWG SPOS 600V
12pr 18AWG SPOS 600V
16pr 18AWG SPOS 600V
24pr 18AWG SPOS 600V
36pr 18AWG SPOS 600V
2pr 16AWG SPOS 600V
4pr 20AWG OS 300V
8pr 20AWG OS 300V
12pr 20AWG OS 300V
16pr 20AWG OS 300V
24pr 20AWG OS 300V
36pr 20AWG OS 300V
50pr 20AWG OS 300V
2pr 18AWG OS 600V
4pr 18AWG OS 600V
8pr 18AWG OS 600V
12pr 18AWG OS 600V
16pr 18AWGOS 600V
24pr 18AWG OS 600V
2pr 16AWG OS 600V
4pr 16AWG OS 600V
8pr 16AWG OS 600V
12pr 16AWG OS 600V
16pr 16AWG OS 600V
24pr 16AWG OS 600V
2pr 20AWG SPOS 300V
4pr 20AWG SPOS 300V
8pr 20AWG SPOS 300V
1466A
1467A
1468A
1471A
1472A
1474A
1475A
1476A
1477A
1480A
1481A
1484A
1485A
1486A
1489A
1490A
1492A
1493A
1494A
1495A
1498A
1499A
3025A
3030A
3031A
3032A
3033A
3034A
3035A
3036A
3037A
3038A
3039A
3041 A
3042A
3043A
3044A
3045A
3046A
3047A
3048A
3049A
3050A
3051A
3052A
3053A
3054A
3055A
671123
669633
671115
671107
671099
669671
669689
669721
669713
671412
671420
671198
671164
671172
671297
671131
671222
671230
671248
671255
671446
671453
669739
675256
1-866-6-NEXANS
14
675215
676403
676411
671404
671040
671065
671081
671156
671271
671321
671693
671289
671438
Description
4pr 18AWG OS 300V
8pr 18AWG OS 300V
12pr 18AWG OS 300V
24pr 18AWG OS 300V
36pr 18AWG OS 300V
2pr 18AWG SPOS 300V
4pr 18AWG SPOS 300V
8pr 18AWG SPOS 300V
12pr 18AWG SPOS 300V
24pr 18AWG SPOS 300V
36pr 18AWG SPOS 300V
4pr 16AWG OS 300V
8pr 16AWG OS 300V
12pr 16AWG OS 300V
24pr 16AWG OS 300V
36pr 16AWG OS 300V
2pr 16AWG SPOS 300V
4pr 16AWG SPOS 300V
8pr 16AWG SPOS 300V
12pr 16AWG SPOS 300V
24pr 16AWG SPOS 300V
36pr 16AWG SPOS 300V
2pr 18AWG OS 300V
4tr 18AWG OS 300V
4tr 18AWG STOS 300V
8tr 18AWG OS 300V
8tr 18AWGST OS 300V
16pr 18AWG OS 300V
16pr 18AWG SPOS 300V
16tr 18AWG OS 300V
16tr 18AWG STOS 300V
24tr 18AWG OS 300V
24tr 18AWG STOS 300V
50pr 18AWG OS 300V
50pr 18AWG SPOS 300V
2pr 16AWG OS 300V
2tr 16AWG OS 300V
2tr 16AWG STOS 300V
4tr 16AWG OS 300V
4tr 16AWG STOS 300V
8tr 16AWG OS 300V
8tr 16AWG STOS 300V
16pr 16AWG OS 300V
16pr 16AWG SPOS 300V
16tr 16AWG OS 300V
16tr 16AWG STOS 300V
24tr 16AWG OS 300V
24tr 16AWG STOS 300V
Instrumentation Cable
Belden Cross-Reference by Part Number (continued)
Belden
Part
Number
Nexans
Part
Number
1078A
1079A
1080A
1081A
1082A
1083A
1084A
1085A
1086A
1087A
1088A
1089A
1090A
1091A
1092A
1093A
1094A
1095A
1096A
1097A
1098A
1099A
1100A
671263
671362
671370
671388
671396
627190
631291
627216
631267
631408
631416
697565
631390
627133
627141
Description
12pr 20AWG SPOS 300V
16pr 20AWG SPOS 300V
24pr 20AWG SPOS 300V
36pr 20AWG SPOS 300V
50pr 20AWG SPOS 300V
4tr 20AWG STOS 300V
8tr 20AWG STOS 300V
12tr 20AWG STOS 300V
24tr 20AWG STOS 300V
36pr 18AWG OS 600V
50pr 18AWG OS 600V
36pr 16AWG OS 600V
50pr 16AWG OS 600V
20pr 20AWG SPOS 300V
16tr 20AWG STOS 300V
4tr 18AWG STOS 600V
8tr 18AWG STOS 600V
12tr 18AWG STOS 600V
24tr 18AWG STOS 600V
4tr 16AWG STOS 600V
8tr 16AWG STOS 600V
12tr 16AWG STOS 600V
24tr 16AWG STOS 600V
Belden
Part
Number
Nexans
Part
Number
3056A
3057A
3064A
3066A
3068A
3069A
3080A
3081A
3088A
3089A
3090A
3091A
671149
671487
671054
672063
669226
669085
669101
669119
697391
697888
Description
50pr 16AWG OS 300V
50pr 16AWG SPOS 300V
2tr 18AWG STOS 600V
16tr 18AWG STOS 600V
12tr 18AWG STOS 300V
12tr 16AWG STOS 300V
1pr 14AWG OS 600V
1tr 14AWG OS 600V
1pr 18AWG OS 600V
1tr 18AWG OS 600V
1pr 16AWG OS 600V
1tr 16AWG OS 600V
The cross-reference to Belden part numbers are provided for informational purposes only, and Nexans makes no
representation or warranty, either express or implied, as to the accuracy of any such cross-reference. Belden is not in any way
associated with Nexans. Belden is a registered trademark of Belden Wire & Cable Company.
1-866-6-NEXANS
15
Instrumentation Cable
Belden Cross-Reference by Description
Description
1pr 20AWG
1tr 20AWG
2pr 20AWG
4pr 20AWG
4tr 20AWG
8pr 20AWG
12pr 20AWG
8tr 20AWG
16pr 20AWG
12tr 20AWG
20pr 20AWG
24pr 20AWG
16tr 20AWG
36pr 20AWG
24tr 20AWG
50pr 20AWG
1pr 18AWG
1tr 18AWG
2pr 18AWG
2tr 18AWG
4pr 18AWG
6pr 18AWG
4tr 18AWG
8pr 18AWG
12pr 18AWG
8tr 18AWG
16pr 18AWG
12tr 18AWG
24pr 18AWG
16tr 18AWG
36pr 18AWG
24tr 18AWG
50pr 18AWG
300 Volt - OS
Overall Shield
600 Volt - OS
Overall Shield
Belden
Part
Number
Nexans
Part
Number
1033A
1526A
669606
669747
1056A
671206
1057A
1058A
671219
671180
1059A
671305
1060A
671313
1061A
671339
1062A
671347
1032A
1036A
3025A
669614
669622
669739
3088A
3089A
1063A
669101
669119
631275
1466A
671123
675264
675256
669633
671115
675215
676411
1064A
631283
697490
1065A
1066A
627489
697672
1067A
627208
671107
1068A
697276
671099
1087A
627190
671065
1088A
631291
3030A
1467A
1468A
3032A
3034A
1471A
3036A
1472A
3038A
3041 A
Belden
Part
Number
Nexans
Part
Number
1-866-6-NEXANS
16
300 Volt - SPOS
Shielded Pairs/Triads
Overall Shield
600 Volt - SPOS
Shielded Pairs/Triads
Overall Shield
Belden
Part
Number
Nexans
Part
Number
Belden
Part
Number
Nexans
Part
Number
1075A
1076A
1083A
1077A
1078A
1084A
1079A
1085A
1091A
1080A
1092A
1081A
1086A
1082A
669705
669820
1474A
669671
631358
1475A
669689
1048A
3064A
1049A
3031A
1476A
1477A
3033A
3035A
3068A
1480A
3037A
1481A
3039A
3042A
669697
671263
671362
671370
671388
671396
669721
669713
676403
671404
671504
671412
671420
671040
671081
1093A
1050A
1051A
1094A
1052A
1095A
1053A
3066A
1054A
1096A
1038A
631366
687780
631408
631374
631382
631416
697532
697565
697540
697557
627919
Instrumentation Cable
Belden Cross-Reference by Description (continued)
Description
1pr 16AWGNS
1pr 16AWG
1tr 16AWG NS
1tr 16AWG
2pr 16AWG
3pr 16AWG
2tr 16AWG
4pr 16AWG
6pr 16AWG
4tr 16AWG
8pr 16AWG
12pr 16AWG
8tr 16AWG
16pr 16AWG
12tr 16AWG
20pr 16AWG
24pr 16AWG
16tr 16AWG
36pr 16AWG
24tr 16AWG
50pr 16AWG
1pr 14AWG
1tr 14AWG
300 Volt - OS
Overall Shield
600 Volt - OS
Overall Shield
300 Volt - SPOS
Shielded Pairs/Triads
Overall Shield
600 Volt - SPOS
Shielded Pairs/Triads
Overall Shield
Belden
Part
Number
Nexans
Part
Number
Belden
Part
Number
Nexans
Part
Number
671222
1055A
1037A
631309
631317
671230
669754
671271
671248
671255
671693
671438
672063
1039A
1040A
1097A
1041A
1042A
1098A
1043A
1099A
1044A
1045A
631325
631333
631390
631341
697508
627133
697516
627141
1046A
1100A
1047A
680413
Belden
Part
Number
Nexans
Part
Number
Belden
Part
Number
Nexans
Part
Number
1035A
1030A
1034A
1031A
3043A
669937
669580
3090A
697391
669598
671156
3091A
1069A
697888
631242
1492A
671198
1070A
631440
3045A
1493A
3044A
1484A
3046A
1485A
1486A
3048A
3050A
1489A
3052A
1490A
3054A.
3056A
671164
671172
671321
671289
1071A
1072A
631457
631259
1073A
697474
671297
1074A
697482
671131
1089A
627216
671149
1090A
631267
3080A
3081A
669226
669085
3047A
1494A
1495A
3049A
3051A
3069A
1498A
3053A
1499A
3055A
3057A
671446
671453
671487
697524
The cross-reference to Belden part numbers are provided for informational purposes only, and Nexans makes no
representation or warranty, either express or implied, as to the accuracy of any such cross-reference. Belden is not in any way
associated with Nexans. Belden is a registered trademark of Belden Wire & Cable Company.
1-866-6-NEXANS
17
Instrumentation Cable
Product Data
Test Method
Insulation
Jacket
Temperature Rating
UL 2250 and UL Subject 13
105°C
90°C
Physicals
Original Elongation
UL 2250 and UL Subject 13
100%
100%
Original Tensile Strength
Air Oven Aging
UL 2250 and UL Subject 13
1500 psi
1500 psi
Elongation (% retention minimum)
UL 2250 and UL Subject 13
70%
70%
Tensile Strength (% retention minimum)
UL 2250 and UL Subject 13
65%
45%
Horizontal
UL 2250 and UL Subject 13
pass
Vertical
UL 2250 and UL Subject 13
pass
Cable Tray (70,000 BTU – UL 1685)
UL 2250 and UL Subject 13
Flame
pass
pass
Limiting Oxygen Index
ASTM D 2863
28
27
Cold Bend (temperature –25°C)
UL 2250 and UL Subject 13
no cracks
no cracks
Deformation
UL 2250 and UL Subject 13
pass
pass
Insulation Resistance Constant (minimum at 15.6°C)
UL 2250 and UL Subject 13
3000
Copper Data
AWG
Stranding
Diameter
inches
AWG
Stranding
mm
Diameter
inches
mm
22
Solid
.0254
.645
22
7 × .0100"
.0300
.762
20
Solid
.0320
.813
20
7 × .0121"
.0360
.914
19
Solid
.0359
.912
19
7 × .0142"
.0430
1.092
18
Solid
.0403
1.024
18
7 × .0152"
.0456
1.158
16
Solid
.0508
1.290
16
7 × .0192"
.0576
1.463
14
Solid
.0640
1.626
14
7 × .0242"
.0726
1.844
12
Solid
.0808
2.052
12
7 × .0305"
.0915
2.324
1-866-6-NEXANS
18
WARNING
NOTICE
FLAMMABLE
Non-metallic covering of electrical
cables will burn and under certain
conditions may transmit fire when
ignited.
Nexans has endeavoured to ensure the
accuracy of the data in this publication,
however we cannot be liable for the
consequences of errors or omissions.
All data is subject to change without
notice. The installer and/or user assumes
all liability for the consequences of the
installation and/or use of any of our
products in contravention of any
applicable law, regulation or code.
TOXIC
Burning non-metallic coverings may
emit acid gases, which are highly toxic,
and may generate dense smoke.
CORROSIVE
Emission of acid gases may corrode
metal in the vicinity, such as sensitive
instruments and reinforcing rod in
concrete.
1-866-6-NEXANS
19
Download