Fire Alarm Wires

advertisement
Multi-Conductor, Unshielded, Non-Plenum
Product Construction
NEC Type FPLR
CONDUCTOR:
s
Solid bare copper
INSULATION:
NO. OF
COND.
AWG.
SIZE
NOM. JACKET
WALL
s
WEIGHT
JACKET:
s
COND.
STRAND
INCHES
MM
INCHES
MM
INCHES
POUNDS
Solid
Solid
Solid
Solid
0.010
0.010
0.010
0.010
0.25
0.25
0.25
0.25
0.015
0.015
0.015
0.015
0.38
0.38
0.38
0.38
0.150
0.175
0.210
0.230
16 lbs.
29 lbs.
41 lbs.
53 lbs.
18 AWG CONDUCTORS
s
W181P-1604
W184C-1602
W186C-1654
W188C-1667
2
4
6
8
18
18
18
18
s
s
Solid
Solid
0.010
0.010
0.25
0.25
0.015
0.015
0.38
0.38
0.172
0.202
23 lbs.
42 lbs.
14 AWG CONDUCTORS
W141P-1607
2
14
W144C-1651
4
14
Solid
Solid
0.013
0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.210
0.248
36 lbs.
66 lbs.
s
s
s
s
s
0.013
0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.244
0.288
53 lbs.
99 lbs.
Wiring of fire alarms
Smoke detectors
Voice communications
Burglar alarms
Fire protective circuits
Suggested voltage rating: 300 volts
COMPLIANCES:
s
Solid
Solid
Premium grade, Red PVC, other jacket colors
may be available – consult sales office
Suitable for use from 20˚C to + 75˚C
Round constructions have sequential
footage markings to facilitate installation
Includes ripcord on round constructions
APPLICATIONS:
s
16 AWG CONDUCTORS
W161P-1601
2
16
W164C-1614
4
16
12 AWG CONDUCTORS
W121P-1624
2
12
W124C-1656
4
12
Premium grade, color coded, S-R PVC
NOMINAL
O.D.
FIRE ALARM/
LIFE SAFETY
PART NUMBER
NOM. INSUL.
THICKNESS
s
s
s
UL Type FPLR (UL: 75˚C, 300V)
NEC Article 760
California State Fire Marshall Approved
Designed to meet UL 1666 Flame Test
PACKAGING:
Color Code Chart
NO. OF COND.
COLOR
NO. OF COND.
COLOR
1
2
3
Black
Red
Brown
5
6
7
Orange
Yellow
Violet
4
Blue
8
Gray
s
s
1000’ (305m) Reels
Other put-ups available–
consult Customer Service
Multi-Conductor, Shielded, Non-Plenum
Product Construction
NEC Type FPLR
CONDUCTOR:
s
Solid bare copper
INSULATION:
s
Premium grade, color coded, S-R PVC
SHIELD:
PART NUMBER
NO. OF
COND.
AWG.
SIZE
s
COND.
STRAND
NOM. INSUL.
THICKNESS
INCHES
MM
NOM. JACKET
WALL
INCHES
MM
NOMINAL
O.D.
INCHES
WEIGHT
POUNDS
Solid
Solid
0.010
0.010
0.015
0.015
0.158
0.183
19 lbs.
32 lbs.
JACKET:
18 AWG CONDUCTORS
W181P-1603
W184C-1605
2
4
18
18
0.25
0.25
0.38
0.38
s
s
s
16 AWG CONDUCTORS
W161P-1606
2
16
W164C-1628
4
16
Solid
Solid
0.010
0.010
0.25
0.25
0.015
0.015
0.38
0.38
0.180
0.210
26 lbs.
42 lbs.
14 AWG CONDUCTORS
W141P-1600
2
14
W144C-1650
4
14
Solid
Solid
0.013
0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.218
0.253
41 lbs.
76 lbs.
12 AWG CONDUCTORS
W121P-1653
2
12
W124C-1659
4
12
s
Overall Flexfoil® polyester supported
aluminum foil
Stranded tinned copper drain wire
s
APPLICATIONS:
s
s
s
s
Solid
Solid
0.013
0.013
0.33
0.33
0.015
0.015
0.38
0.38
0.252
0.293
56 lbs.
115 lbs.
s
s
s
NO. OF COND.
COLOR
NO. OF COND.
COLOR
s
1
2
3
4
Black
Red
Brown
Blue
5
6
7
8
Orange
Yellow
Violet
Gray
s
YOUR WIRE AND CABLE CONNECTION
Wiring of fire alarms
Smoke alarms
Voice communications
Burglar alarms
Fire protective circuits
Suggested voltage rating: 300 volts
COMPLIANCES:
s
Color Code Chart
Premium grade, Red PVC, other jacket colors may
be available – consult sales office
Suitable for use from 0°C to + 75°C
Sequential footage markings to
facilitate installation
Includes ripcord
UL Type FPLR (UL: 75°C, 300V)
NEC Article 760
California State Fire Marshall Approved
Designed to Meet UL 1666 Flame Test
PACKAGING:
s
s
1000’ (305m) Reels
Other put-ups available–
consult Customer Service
Sales@Connect-Air.com
Sales@Connectt-Ai
Air.
r.co
com
co
m
11
Mid-Capacitance,
Shielded, Non-Plenum
Product Construction
NEC Type FPL for Microprocessor Controlled Systems
INSULATION:
CONDUCTOR:
s
s
s
Solid bare copper
Premium grade color coded
polypropylene
Color code: see chart below
SHIELD:
FIRE ALARM/
LIFE SAFETY
s
s
100% Flexfoil® aluminum/polyester,
25% overlap, minimum
Stranded tinned copper drain wire
JACKET:
s
PART NUMBER
NOM. INSUL.
THICKNESS
NOM. JACKET
WALL
NOMINAL
O.D.
NO. OF
COND.
AWG.
SIZE
COND.
STRAND
INCHES
MM
INCHES
MM
INCHES
2
2
2
18
16
14
Solid
Solid
Solid
0.014
0.016
0.018
0.36
0.41
0.46
0.020
0.020
0.020
0.51
0.51
0.51
0.182
0.214
0.287
NOMINAL
PF/FT
A*
B*
WEIGHT
POUNDS
s
APPLICATIONS:
s
W181P-1608
W161P-1609
W141P-1649
27.0 49.0 22 lbs.
29.0 52.0 30 lbs.
31.0 55.5 47 lbs.
s
s
s
s
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Color Code Chart
NO. OF COND.
1
2
3
4
COLOR
Black
Red
Brown
Blue
PVC, red
Temperature range: 0°C to + 60°C
s
Addressable fire alarm systems
Fire alarm systems
Voice communications
Smoke detectors
Pull boxes
Suggested voltage rating: 300 volts
COMPLIANCES:
s
s
s
s
UL Type FPL (UL: 60°C, 300V)
NEC Article 760
California State Fire Marshall Approved
Passes UL 70,000 BTU Vertical Tray
Flame Test
PACKAGING:
s 1000’
s
Mid-Capacitance,
Unshielded, Non-Plenum
(30 m) reels
Other put-ups available–
consult Customer Service
Product Construction
CONDUCTOR:
s
NEC Type FPL for Microprocessor Controlled Systems
18 thru 12 AWG fully annealed solid bare
copper per ASTM B3
INSULATION:
s
Premium grade color coded
polypropylene
s Color code: see chart below
JACKET:
s
s
PVC, red
Temperature range: – 20°C to + 60°C
APPLICATIONS:
PART NUMBER
W181P-1617
W161P-1647
W141P-1656
NOM. INSUL.
THICKNESS
NOM. JACKET
WALL
NO. OF
COND.
AWG.
SIZE
COND.
STRAND
INCHES
MM
INCHES
MM
2
2
2
18
16
14
Solid
Solid
Solid
0.014
0.016
0.018
0.36
0.41
0.46
0.020
0.020
0.020
0.51
0.51
0.51
NOMINAL
O.D.
Addressable fire alarm systems
Fire alarm systems
s Voice communications
s Smoke detectors
s Pull boxes
s Suggested voltage rating: 300 volts
s
INCHES
NOM. C-C CAP.
PF/FT*
WEIGHT
POUNDS
0.177
0.206
0.240
16.5
17.5
18.0
22 lbs.
30 lbs.
38 lbs.
s
COMPLIANCES:
s
UL Type FPL (UL: 60°C, 300V)
NEC Article 760
s California State Fire Marshall Approved
s Passes UL 70,000 BTU Vertical Tray
Flame Test
s
Color Code Chart
NO. OF COND.
1
2
3
4
12
CONNECT-AIR WIRE AND CABLE
COLOR
Black
Red
Brown
Blue
PACKAGING:
1000’ (305m) Reels
500’ (152m) Reels
s Other put-ups available–
consult Customer Service
s
s
Multi-Conductor,
Shielded, Direct Burial
Product Construction
NEC Type FPL / PLTC 300V
INSULATION:
CONDUCTOR:
s
s
s
Stranded copper per ASTM B3
PVC with nylon
Color code: see chart below
SHIELD:
s
JACKET:
s
s
PART NUMBER
W181P-1676
W161P-1661
W141P-1662
NO. OF
COND.
AWG.
SIZE
COND.
STRAND
2
2
2
18
16
14
7/26
7/24
19/27
NOM. INSUL.
THICKNESS
INCHES
MM
NOM. JACKET
WALL
INCHES
0.015 0.005 0.040
0.015 0.005 0.040
0.015 0.005 0.040
NOMINAL
O.D.
MM
INCHES
WEIGHT
POUNDS
1.02
1.02
1.02
0.310
0.328
0.350
48 lbs.
58 lbs.
75 lbs.
s
APPLICATIONS:
s
s
s
s
s
Color Code Chart
NO. OF COND.
PVC, Black
Temperature range: – 20°C to + 105°C
dry locations, 75°C wet locations
Includes ripcord
FIRE ALARM/
LIFE SAFETY
s
100% Flexfoil® aluminum/polyester foil,
25% overlap, minimum
Stranded tinned copper drain wire
COLOR
1
2
3
Black
Red
Brown
4
Blue
Fire alarm systems
Smoke detectors
Fire protective circuits
Burglar alarms
Suggested voltage rating: 300 volts
COMPLIANCES:
s
s
s
UL Type PLTC/FPLR (UL: 105°C, 300V)
NEC Article 760
California State Fire Marshall Approved
FEATURES:
s
s
s
Sunlight and moisture resistant jacket
Sequentially footage marked
Water blocked construction
PACKAGING:
s
s
1000’ (305m) Reels
Other put-ups available–
consult Customer Service
Product Construction
Multi-Conductor,
Unshielded, Direct Burial
CONDUCTOR:
s
Stranded bare copper
INSULATION:
NEC Type FPL / PLTC 300V
s
s
PVC with nylon
Color code: see chart below
JACKET:
s
s
s
PVC, Black
Temperature range: – 20°C to + 105°C
dry locations, 75°C wet locations
Includes ripcord
APPLICATIONS:
s
PART NUMBER
NOM. INSUL.
THICKNESS
NOM. JACKET
WALL
NOMINAL
O.D.
s
NO. OF
COND.
AWG.
SIZE
COND.
STRAND
INCHES
MM
INCHES
MM
INCHES
WEIGHT
POUNDS
2
4
2
2
4
18
18
16
14
14
7/26
7/26
7/24
19/27
19/27
0.015
0.015
0.015
0.015
0.015
0.005
0.005
0.005
0.005
0.005
0.040
0.040
0.040
0.040
0.040
1.02
1.02
1.02
1.02
1.02
0.270
0.327
0.295
0.310
0.395
37 lbs.
59 lbs.
48 lbs.
59 lbs.
98 lbs.
s
s
s
W181P-1679
W184C-1693
W161P-1657
W141P-1663
W144C-1699
Fire alarm systems
Voice communications
Smoke detectors
Burglar Alarms
Suggested voltage rating: 300 volts
COMPLIANCES:
s
s
s
UL Type PLTC/FPLR (UL: 105°C, 300V)
NEC Article 760
California State Fire Marshall Approved
FEATURES:
s
Color Code Chart
s
Sunlight and moisture resistant jacket
Sequentially footage marked
Water blocked construction
COLOR
s
1
2
3
Black
Red
Brown
PACKAGING:
4
Blue
NO. OF COND.
YOUR WIRE AND CABLE CONNECTION
s
s
1000’ (305m) Reels
Other put-ups available–
consult Customer Service
Sales@Connect-Air.com
Sales@Connectt-Ai
Air.
r.co
com
co
m
13
Multi-Conductor, Type MC
FPLP/MC 300V/600V
Product
Construction
Red Fire Alarm/Control Cable™
ARMOR:
s
Galvanized interlocking Steel
Strip (red-striped)
CONDUCTORS:
FIRE ALARM/
LIFE SAFETY
s
Solid copper
CONDUCTOR INSULATION:
s
AFC Cable Systems
ASSEMBLY:
Multi-Conductor, Unshielded, Type MC
PART NUMBER
NO. OF
COND.
s
2
4
COND.
STRAND
NOMINAL
O.D.
WEIGHT
18
18
Solid
Solid
0.410
0.430
115 lbs.
130 lbs.
s
Solid
Solid
0.420
0.440
130 lbs.
155 lbs.
14 AWG CONDUCTORS
W141P-1607MC
2
14
W144C-1651MC
4
14
Solid
Solid
0.470
0.510
175 lbs.
230 lbs.
s
s
s
s
Multi-Conductor, Type CI
COND.
STRAND
NOMINAL
O.D.
NO. OF AWG.
COND. SIZE
COND.
STRAND
NOMINAL
O.D.
CONDUCTOR:
s
WEIGHT
18
18
Solid
Solid
0.390
0.445
82 lbs.
127 lbs.
W181P-1603CI
W184C-1605CI
2
4
18
18
Solid
Solid
0.310
0.355
s
54 lbs.
77 lbs.
14 AWG CONDUCTORS
W141P-1607CI
2
14
W144C-1651CI
4
14
Solid
Solid
Solid*
Solid*
0.350
0.400
0.390
0.445
64 lbs.
96 lbs.
16 AWG CONDUCTORS
W161P-1606CI
2
16
W164C-1628CI
4
16
Solid
Solid
0.330
0.375
82 lbs.
127 lbs.
14 AWG CONDUCTORS
W141P-1600CI
2
14
W144C-1650CI
4
14
Solid*
Solid*
0.370 81 lbs.
0.425 126 lbs.
2-hour fire rated – FPLR-CI
COMPLIANCES:
s
16 AWG CONDUCTORS
W161P-1601CI
2
16
W164C-1614CI
4
16
Solid copper
APPLICATIONS:
18 AWG CONDUCTORS
18 AWG CONDUCTORS
2
4
PART NUMBER
300V (FPLP)
600V (MC)
CI Product
Construction
Multi-Conductor, Shielded, Type CI
WEIGHT
FPLP: 105° (dry)
MC: 90° (dry)
MAXIMUM VOLTAGE RATING:
s
NO. OF AWG.
COND. SIZE
Cable tray installations per NEC
NFPA 262 (formerly U.L. 910)
Plenum rated – Type FPLP
MAXIMUM TEMPERATURE RATING:
s
Multi-Conductor, Unshielded, Type CI
Fire Alarm/Control Type MC – FPLP
COMPLIANCES:
s
W181P-1604CI
W184C-1602CI
Bare or insulated green
APPLICATIONS:
16 AWG CONDUCTORS
W161P-1601MC
2
16
W164C-1614MC
4
16
PART NUMBER
Polyester assembly tape
GROUNDING:
AWG.
SIZE
18 AWG CONDUCTORS
W181P-1604MC
W184C-1602MC
TFN and/or THHN
s
63 lbs.
96 lbs.
UL 2196
NFPA 262 (formerly U.L. 910)
MAXIMUM VOLTAGE RATING:
s
FPL – 300V
*May be stranded construction. Consult your sales representative.
CIC Product
Construction
Multi-Conductor, Type CIC
Multi-Conductor, Unshielded, Type CIC
PART NUMBER
NO. OF
COND.
AWG.
SIZE
COND.
STRAND
NOMINAL
O.D.
WEIGHT
18 AWG CONDUCTORS
W181P-1604CIC
W184C-1602CIC
2
4
PART NUMBER
NO. OF
COND.
s
18
18
Solid
Solid
0.330
0.370
AWG.
SIZE
COND.
STRAND
NOMINAL
O.D.
WEIGHT
18
18
Solid
Solid
0.330
0.385
57 lbs.
81 lbs.
W181P-1603CIC
W184C-1605CIC
62 lbs.
94 lbs.
16 AWG CONDUCTORS
W161P-1606CIC 2
16
W164C-1628CIC 4
16
Solid
Solid
0.350
0.400
66 lbs.
99 lbs.
14 AWG CONDUCTORS
W141P-1600CIC 2
14
Solid* 0.400
85 lbs.
W144C-1650CIC
Solid* 0.450 130 lbs.
16 AWG CONDUCTORS
W161P-1601CIC
2
16
W164C-1614CIC 4
16
Solid
Solid
0.330
0.400
14 AWG CONDUCTORS
W141P-1607CIC
2
14
W144C-1651CIC 4
14
Solid*
Solid*
0.390 80 lbs.
0 440 125 lbs.
CONNECT-AIR WIRE AND CABLE
4
s
2-hour fire rated – FPL/-NPLF
COMPLIANCES:
53 lbs.
76 lbs.
2
4
Solid copper
APPLICATIONS:
18 AWG CONDUCTORS
*May be stranded construction. Consult your sales representative.
14
CONDUCTOR:
Multi-Conductor, Shielded, Type CIC
14
s
s
UL 2196
NFPA 262 (formerly U.L. 910)
MAXIMUM VOLTAGE RATING:
s
s
FPL – 300V
NPLR – 150V
NOTE:
2-hour rated cable must be
installed in conduit for any
high-rise building over 75 feet,
any federal building, and areas of
assembly (1000 or more people).
Multi-Conductor, Unshielded, Plenum
Product Construction
CONDUCTOR:
NEC Type FPLP
s
18 thru 12 AWG fully annealed solid
bare copper per ASTM B3
INSULATION:
s
Premium grade, color coded,
Plenum Rated PVC
JACKET:
AWG.
SIZE
COND.
STRAND
18 AWG CONDUCTORS
W181P-2600
2
18
W184C-2607
4
18
W186C-2651
6
18
Solid
Solid
Solid
0.010
0.010
0.010
0.25
0.25
0.25
0.015
0.015
0.015
0.38
0.38
0.38
0.155
0.175
0.211
17 lbs.
30 lbs.
57 lbs.
16 AWG CONDUCTORS
W161P-2601
2
16
W164C-2637
4
16
Solid
Solid
0.010
0.010
0.25
0.25
0.015
0.015
0.38
0.38
0.172
0.202
24 lbs.
45 lbs.
14 AWG CONDUCTORS
W141P-2611
2
14
W144C-2640
4
14
Solid
Solid
0.012
0.012
0.30
0.30
0.015
0.015
0.38
0.38
0.210
0.243
36 lbs.
66 lbs.
12 AWG CONDUCTORS
W121P-2613
2
12
W124C-2641
4
12
Solid
Solid
0.012
0.012
0.30
0.30
0.015
0.015
0.38
0.38
0.244
0.284
52 lbs.
100 lbs.
PART NUMBER
NO. OF
COND.
NOM. JACKET
WALL
INCHES
MM
NOMINAL
O.D.
INCHES
WEIGHT
POUNDS
Premium grade, Red Plenum Rated PVC,
other jacket colors may be available –
consult sales office
s Suitable for use from 0°C to + 75°C
s Sequential footage markings to
facilitate installation
s Includes ripcord
APPLICATIONS:
FIRE ALARM/
LIFE SAFETY
s
NOM. INSUL.
THICKNESS
INCHES
MM
s
Wiring of fire alarms
Smoke detectors
s Voice communications
s Burglar alarms
s Fire protective circuits
s Suggested voltage rating: 300 volts
s
COMPLIANCES:
Color Code Chart
s
UL Type FPLP (UL: 75°C, 300V)
NEC Article 760
s California State Fire Marshall Approved
s Designed to meet UL 910 flame test
s
PACKAGING:
NO. OF COND.
COLOR
NO. OF COND.
COLOR
s
1
2
3
Black
Red
Brown
4
5
6
Blue
Orange
Yellow
s
1000’ (305m) Reels
Other put-ups available–
consult Customer Service
Product Construction
Multi-Conductor, Shielded, Plenum
CONDUCTOR:
NEC Type FPLP
INSULATION:
s
s
Solid bare copper
Premium grade, color coded, Plenum Rated PVC
SHIELD:
s
s
100% aluminum foil/polyester
Stranded tinned copper drain wire
JACKET:
PART NUMBER
NO. OF
COND.
AWG.
SIZE
s
COND.
STRAND
NOM. INSUL.
THICKNESS
INCHES
MM
NOM. JACKET
WALL
INCHES
MM
NOMINAL
O.D.
INCHES
WEIGHT
POUNDS
Solid
Solid
Solid
0.010
0.010
0.010
0.015
0.015
0.015
0.155
0.183
0.216
21 lbs.
34 lbs.
47 lbs.
18 AWG CONDUCTORS
W181P-2601
W184C-2621
W186C-2644
2
4
6
18
18
18
0.25
0.25
0.25
0.38
0.38
0.38
Premium grade, Red Plenum Rated PVC,
other jacket colors may be available –
consult sales office
s Suitable for use from 0°C to + 75°C
s Sequential footage markings to facilitate
installation
s Includes ripcord
APPLICATIONS:
s
16 AWG CONDUCTORS
W161P-2602
2
16
W164C-2604
4
16
Solid
Solid
0.010
0.010
0.25
0.25
0.015
0.015
0.38
0.38
0.180
0.210
28 lbs.
49 lbs.
14 AWG CONDUCTORS
W141P-2605
2
14
W144C-2642
4
14
Solid
Solid
0.012
0.012
0.30
0.30
0.015
0.015
0.38
0.38
0.210
0.248
43 lbs.
76 lbs.
12 AWG CONDUCTORS
W121P-2645
2
12
W124C-2641
4
12
Wiring of fire alarms
Smoke detectors
s Voice communications
s Burglar alarms
s Fire protective circuits
s Suggested voltage rating: 300 volts
s
COMPLIANCES:
s
UL Type FPLP (UL: 75°C, 300V)
NEC Article 760
s California State Fire Marshall Approved
s Designed to meet UL 910 Flame Test
s
Solid
Solid
0.012
0.012
0.30
0.30
0.015
0.015
0.38
0.38
0.252
0.300
57 lbs.
114 lbs.
PACKAGING:
1000’ (305m) Pull-Pac® Cartons
(18 and 16 AWG items only)
s 1000’ (305m) reels
s 500’ (152m) spools or reels
s Other put-ups available–
consult Customer Service
s
Color Code Chart
NO. OF COND.
COLOR
NO. OF COND.
COLOR
1
2
3
Black
Red
Brown
4
5
6
Blue
Orange
Yellow
YOUR WIRE AND CABLE CONNECTION
Sales@Connect-Air.com
Sales@Connectt-Ai
Air.
r.co
com
co
m
15
Mid-Capacitance, Shielded, Plenum
Product Construction
CONDUCTOR:
NEC Type FPLP for Microprocessor Controlled Systems
s
Solid bare copper
INSULATION:
s
Premium grade color coded
Fluoropolymer
s Color code: see chart below
FIRE ALARM/
LIFE SAFETY
SHIELD:
s
PART NUMBER
W181P-2620
W161P-2634
W141P-2635
NO. OF
COND.
AWG.
SIZE
COND.
STRAND
NOM. INSUL.
THICKNESS
INCHES
MM
2
2
2
18
16
14
Solid
Solid
Solid
0.014
0.016
0.018
0.36
0.41
0.46
NOM. JACKET
WALL
INCHES
MM
NOMINAL
O.D.
INCHES
0.015
0.015
0.020
0.172 22 lbs. 31.0 56.0
0.203 35 lbs. 33.0 59.0
0.247 35 lbs. 35.0 63.0
0.38
0.38
0.51
NOMINAL CAP.*
PF/FT
A*
B*
WEIGHT
LBS
s
100% aluminum/polyester foil
Stranded tinned copper drain wire
JACKET:
Premium grade, Red Plenum Rated PVC
Temperature range: 0°C to + 75°C
s Includes ripcord
s
s
APPLICATIONS:
s
*A – Capacitance between conductors
*B – Capacitance between one conductor and other conductors connected to shield
Addressable fire alarm systems
Fire alarm systems
s Voice communications
s Smoke detectors
s Pull boxes
s Suggested voltage rating: 300 volts
s
Color Code Chart
NO. OF COND.
1
2
3
4
COLOR
Black
Red
Brown
Blue
COMPLIANCES:
s
UL Type FPLP (UL: 75°C, 300V)
NEC Article 760
s California State Fire Marshall Approved
s Designed to Meet UL 910 Flame Test
s
PACKAGING:
s
s
Mid-Capacitance, Unshielded, Plenum
Product Construction
CONDUCTOR:
s
NEC Type FPLP for Microprocessor Controlled Systems
1000’ (30 m) Reels
Other put-ups available–
consult Customer Service
Solid bare copper
INSULATION:
s
Premium grade color coded
Fluoropolymer
s Color code: see chart below
JACKET:
s
Premium grade, Red Plenum Rated PVC
Temperature range: 0°C to + 75°C
s Includes ripcord
s
PART NUMBER
NO. OF
COND.
AWG.
SIZE
COND.
STRAND
NOM. INSUL.
THICKNESS
INCHES
MM
NOM. JACKET
WALL
INCHES
MM
NOMINAL
O.D.
INCHES
WEIGHT
POUNDS
NOMINAL C-CAP.
PF/FT*
2
2
2
2
18
16
14
12
Solid
Solid
Solid
Solid
0.014
0.016
0.018
0.020
0.015
0.015
0.020
0.020
0.172
0.196
0.242
0.282
18 lbs.
31 lbs.
43 lbs.
63 lbs.
19.0
20.0
20.0
22.0
APPLICATIONS:
s
W181P-2622
W161P-2633
W141P-2646
W121P-2643
0.36
0.41
0.46
0.46
0.38
0.38
0.51
0.51
* Capacitance between conductors
Addressable fire alarm systems
Fire alarm systems
s Voice communications
s Smoke detectors
s Pull boxes
s Suggested voltage rating: 300 volts
s
COMPLIANCES:
s
Color Code Chart
NO. OF COND.
1
2
3
4
16
CONNECT-AIR WIRE AND CABLE
COLOR
Black
Red
Brown
Blue
UL Type FPLP (UL: 75°C, 300V)
NEC Article 760
s California State Fire Marshall Approved
s Designed to Meet UL 910 Flame Test
s
PACKAGING:
s
s
1000’ (305m) Reels
Other put-ups available–
consult Customer Service
Download