GFI - GRID FEED INVERTER About DVE Technologies ApS The organisation behind DVE Technologies has more than 30 years experience in R&D and production of high tech electrical Cleantech components. As an OEM supplier for small wind turbines manufacturers we have gained a high level of knowledge and competence within this segment. DVE Technologies working area is securing the overall system reliability and most important the total power conversion efficiency. Let us help you gain the most out of your small wind turbine. DVE Technologies ApS Phone: +45 7384 8512 Sdr. Tingvej 8 DK-6630 Rødding Mail: info@dvetech.com www.dvetech.com Intelligent wind turbine control GFI - Grid Feed Inverter Complete system integration Benefits The GFI - Grid Feed Inverter is an optimized cabinet assembly providing you a complete control system for your small wind turbine. The GFI contains everything needed from turbine power conversion, control and monitoring, external equipment interfacing and power feed in to the grid according to legislations in Europe. • Complete control system • Precisely programmable power curve based on rotor speed (up to 100 set-points) • Easy plug & play installation • Optimized design for easy OEM cabinet integration • Interface for generator thermal protection • Complete system integration • Low cut-in wind speed • High energy capture • All-in-one product • Excellent return on investment (ROI) The GFI Grid Feed Inverter is designed for the OEM’s offering a fast and cost effective integration. This advanced grid feed inverter comes in 6 power sizes from 10kW to 30kW in single and 3-phase versions. Optionals • 4.3” TFT touch display • Programmable logic controller for enhanced system control • Remote user display • Extended warranty Monitoring + setup/commissioning The GFI Grid Feed inverter is specifically designed for small wind turbines but can additionally be used in all induction and permanent magnet generator based system such as Hydro Power, Wave Energy, Biomass and CHP systems. The optional multifunctional touch screen panel enables the OEM and end-user to fully observe and monitor the GFI inverter. This can be done either on-site or together with the standard web monitoring solution from DVE Technologies. GENERAL SPECIFICATIONS GFI-110K Operating temperature GFI-115K GFI-310K GFI-315K Safety devices AC side ≤ 95% non-condensating Operating Altitude 2000m Safety Class 50 kg 50 kg 50 kg 50 kg 58 kg 85 kg 952x594x364mm 952x594x364mm 952x594x364mm 952x594x364mm 952x594x364mm 952x594x364mm GRID OUTPUT (AC) 10 kW 15 kW 10 kW 15 kW 20 kW 30 kW Maximum power 10.5 kVA 16 kVA 10.5 kVA 16 kVA 21 kVA 32 kVA Nominal current (rms) 1 x 48 A 1 x 72 A 3 x 16 A 3 x 24 A 3 x 32 A 3 x 48 A ≤ 125% x nom. current Frequency nominal 50 / 60 Hz Frequency range 45-65 Hz Nominal power factor > 0.99 at full power Power factor (cos) 0.80 inductive – 0.80 capacitive DC current injection 0.25% of rated current Harmonic distortion < 3 % THDI Stand by power (off grid) <5W Maximum efficiency 96 % Fuse 0-450 V AC 3P Maximum input voltage (not operating) 1000 V AC 3P Operating input generator voltage Nominal power factor Power factor (cos) Directive LVD 2006/95/EC Directive EMC 2004/108/EC Safety EMC immunity 3 x 30 A 3 x 20 A 3 x 30 A 3 x 40 A EN 61000-6-3, EN 61000-6-4 Utility interference EN 61000-3-11/-12 EN 61000-3-11/-12 - - > 0.99 at full power 0.80 inductive – 0.80 capacitive EN 61000-3-11/-12 FUNCTIONAL SAFETY Germany (DE) United Kingdom (UK) VDE 0126-1-1/A1, VDE AR-N 4105 (August 2011) G59/3 G59/3 France (FR) - - G83/2 UTE C15-712-1 Belgium (BE) - - Synergrid C10/11 – Rev 2012-06, Synergrid C10/17- Rev 8 may 2009 France (FR) - - UTE NF C 15-712-1 Denmark (DK) - - Spain (ES) - - G59/3 Portugal (PT) - - TF 3.2.1 G59/3 G59/3 Guidelines for energy plants greater than 16A RD1699 (2011) RD661 (2007) VDE 0126-1-1, ISO/IEC Guide 67: 2004 - System No.5 Active Generator Converter Generator relay 3 x 48 A igen N PWM Grid Converter PWM L1 (+L2,L3) Main relay N igrid Relay control RPM (Optional) Generator control MCU Grid control MCU & Ugrid RS485 communication standard / CAN and Ethernet optional Standard 8 x DI / 4 x AI Thermal sensor input (NTC) EN 61000-3-2/-3 0-300 Hz Galvanic isolated user input (digital / analogue) Free space for customer parts on internal DIN-rail EN 61000-3-11/-12 EN 61000-6-1, EN 61000-6-2 0-550 V AC 3P 3 x 20 A Standard 4 (1 x Wind direction / 2 x Wind speed / 1 x Vibration sensor) Relay contacts user output (change over) EN 61000-3-11/-12 EN 50178 PM or induction generator Wind direction / Wind speed interface / Vibration Galvanic isolated user output (digital) GFI-330K voltage / frequency window redundant AC relays integrated RCD (AC/DC sensitive), trip levels: 30 mA jump, 300 mA continuous DC current injection protection class II surge protection (varistors) SYSTEM INFORMATION User interface and diagnostics GFI-320K External fuses required Rated input genetator voltage Frequency range GFI-315K ©2015 DVE Technologies ApS — Specifications subject to change without prior notice GENERATOR INPUT (AC) Nominal current (rms) • • • • • EMC emission 400 V AC 3P + N + PE ( +/- 20%) Max. inrush current GFI-310K NORMATIVE REFERENCES Class I metal enclosure with protective earth 230 V AC 1P + N + PE ( +/- 20%) GFI-115K Compatible with national standards. Forced cooling by fans Relative humidity Rated power GFI-110K IP42 (enclosure rating EN60529) Cooling Rated grid voltage SAFETY DEVICES Powder coated Protection degree Dimensions (HxWxD) GFI-330K Anti-Islanding protection Enclosure Weight GFI-320K Ambient temperature -20°C to 60°C, recommended 24 hour average ≤ 40°C (derating ≥ 45 °C) CAN Grid protection MCU Ugrid Standard 4 x DO Standard 3 x change over Standard Standard 1 (1x Generator ) Wind turbine controller CAN/RS485/Ethernet Redundant relay RFI filter RCD protection L1 (+L2,L3) N