• Tough EDPM silicon boots are UV-resistant and protect switches from moisture, dust, and dirt
• Built in hex nut base screws accommodates most toggles with 15/32" mounting stems
• Boots are rated for -40˚F to 356˚F (-40˚C-180˚ C)
Part No.
0713544
Mfg. No.
73100
Color
Black
Style
Full Toggle Boot
According to the 2008 National Electric Code
(NEC ® ) article 430.102, all motor controllers must have a disconnecting means located within the line of sight of the controller. Because the NEC ® recognizes that a controller and disconnect can be the same unit (article 430.109),
Bryant has taken the opportunity to design a compact controller that will also meet the rigorous demands of a motor disconnect. Bryant's controllers are listed as "Suitable as Motor Disconnect" under UL Standard 508 – Industrial
Control Equipment – qualifying them to perform both operations in one compact package.
Part No.
Mfg. No. Amps Voltage
0719345 30003D 30 600 - 3 Phase
0726071 30002D 30
0726073 30103D 30
600 - 1 Phase
600 - 3 Phase
Type
Motor Starting Switch
Toggle Switch
Toggle Switch
Style
Industrial
Industrial
Aluminum Enclosure, NEMA 1
®
Hubbell's Circuit-Lock ® Unfused Disconnect Switches are UL listed as a manual motor controller and also "suitable as a motor disconnect" and meet these code requirements. In addition, the enclosure offers the ability to lock directly wired motor loads in the OFF position to comply with OSHA Lockout/Tagout regulations. This safety enclosure is Type 4X (Wash down, Corrosion resistant) and is also suitable for use with metallic conduit. The switch is mounted on an internal frame that is integral with the enclosure and bonds all grounds, and it accepts auxiliary contacts that can be used to signal PLC controllers.
• Conduit hub and adjustable mounting feet are supplied for ease of installation.
• Captured neoprene gasket provides a watertight seal between cover and base.
• Reversible interior accommodates top or bottom conduit opening.
• Type 4X enclosure is molded of rugged Valox ® to resist abuse, corrosion and enhance safety.
• Enclosure Rating: TYPE 4, 4X, 12; IP66 Suitability
Part No.
Mfg. No.
0737213 HBLDS3
Amps
30
0737216 HBLDS3AC 30
0737214 HBLDS33ACNK 30
0737225 HBLDS6
0737227 HBLDS6AC
0737210 HBLDS10
0737211 HBLDS10AC
60
60
100
100
600
600
600
600
Voltage
600
600
600
Width
6.0"
6.0"
6.0"
7.75"
7.75"
7.75"
7.75"
Height
8.5"
8.5"
8.5"
11.0"
11.0"
11.0"
11.0"
10–85
Portable GFCI Line Cords provide ground fault protection both indoors and out. They interrupt electrical power for equipment loads when leakage to ground is 4-6 milliamperes. Available in lengths of 18" (45.7 cm), 6'
(182.9 cm), and 25' (762 cm) and 50' (1524 cm). A 15' (457.2 cm) OEM version with stripped leads is also available. They are offered with an Automatic Set or Manual
Set feature to meet your application.
• High impact UV stabilized housing resists dust, sunlight and chemicals for long life
• Watertight GFCI housing for use in harsh environments
• All-glass circuit board provides superior moisture immunity
• Heavy-duty molded strain relief prevents conductor strain and resulting failure
• Solid (not formed) plug blades are crimped and soldered for a better connection and longer life
• Bright fault indicator light provides fault confirmation from a distance
• One-piece flush sealed keypads for greater reliability and resistance to damage due to impact
• Heavy-duty molded plug and connector for reliable connection
Depth
4.12"
4.12"
4.12"
5.94"
5.94"
5.94"
5.94"
Part No.
Mfg. No.
0733786 GFP2TTA
0733787 GFP2TTM
0733795 GFP3C20M
0733799 GFP4C15A
0733800 GFP4C15M
0733765 GFP15M
0733767 GFP20M
0733809 GFP6C15M
0733808 GFP6C15A
0733778 GFP25C15A
0733779 GFP25C15M
25 ft
25 ft
0733801 GFP50C15WM 50 ft
6 ft
6 ft
6 ft
6 ft
2 ft
2 ft
3 ft
4 ft
4 ft
Length Wire Size Amps Voltage Color
14 AWG
14 AWG
SJTW-A (UL), SJTW
(CSA)
SJTW-A (UL), SJTW
(CSA)
SJTW-A (UL), SJTW
(CSA)
STOW-A (UL), STW
FT2 CSA
STOW-A (UL), STW
FT2 CSA
SJTW-A (UL), SJTW
(CSA)
SJTW-A (UL), SJTW
(CSA)
SJTW-A (UL), SJTW
(CSA)
SJTW-A (UL), SJTW
(CSA)
SJTW-A (UL), SJTW
(CSA)
20
15
15
15
20
15
15
15
15
15
15
15
120
120
120
120
120
120
120
120
120
120
120
120
Yellow /
Black
Yellow /
Black
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Number of
Outlets
3
Style
3
1
1
1
4
4
1
1
1
1
1
Automatic
Reset
Manual
Reset
Manual
Reset
Automatic
Reset
Manual
Reset
Manual
Reset
Manual
Reset
Manual
Reset
Automatic
Reset
Automatic
Reset
Manual
Reset
Manual
Reset
Portable GFCI Line Cords provide ground fault protection both indoors and out. They interrupt electrical power to protect personnel when leakage to ground is 4-6 millamperes.
• Automatic and manual (safe-start) reset options
• Meets OSHA requirements for open neutral relay protection
• Raintight NEMA 3R rated for indoor and outdoor use
• LED indication for power and fault status
• Recessed actuation buttons to reduce damage and accidental operation
• High-impact thermoplastic housings
Part No.
Length Wire Size
0281233 3 ft 14/3 AWG
Amps
15
0709461 2 ft 14/3 AWG 15
Voltage
120
120
Number of Outlets Color
1 Yellow
1
Style
Manual Reset
Yellow / Black Automatic Reset