PDL 56 SERIES - Get the Facts
For over 15 years 56 Series
has earned a reputation for top
performance in resistance to
the harsh treatment of
industrial environments.
Superior Impact Strength
The high-impact strength polycarbonate material used in the manufacture of the 56
Series has a proven superior impact strength 56 Series is proven and tested to
operate in extreme temperatures from-40˚ to 55˚+
High Level of Switch Performance
It is important to be aware that there are major differences in standard specifications
used to specify switch motor ratings. Most of PDL’s 56 Series switches carry AC23A
and AC3 motor ratings to EN60947 and are capable of making up to 8 times and
breaking up to 10 times their rated current, which makes them suitable for DOL
switching of motors.
A motor kilowatt rating is also given for each switch size. Switches carrying an ‘M’
rating only have to pass a few operations at the M current stated, which is to prove
an equivalent to “locked rotor”, not motor switching.
ELECTRICAL
PRODUCTS
Specially-formulated Chemical Resistance
ED
SS
SE
AS
REGISTERED
SUPPLIER
QU
AL
ITY
PDL Electrical Products are
manufactured by
ISO 9002
CERT NO. 11595
NATIONAL
ACCREDITATION
OF CERTIFICATION
BODIES
PDL Industries Limited,
Telarc Reg. No. 061
registered to ISO 9002.
For those environments where harsh chemicals are used such as abbatoirs, dairy
and food processing industries, plastic with special chemical resistant properties is
required. PDL’s chemically–resistant orange and white 56 Series has been developed
with leading plastic material suppliers and has been tried and proven, offering overall
greater resistance to chemical attack than common plastic materials. These products
are easily distinguished from standard 56 Series “electric grey” units by their
industrial orange and white colours. In these harsh environments, you cannot do
better than a specialist chemically resistant product - anything else is not worth the
risk. For finer detail of specific aggressive chemical environments, contact your local
PDL representative.
NEW ZEALAND MADE
Page 2
Solvent Bonding Capability
Greater UV Resistance
PDL’s PVC enclosures are able to be solvent bonded to
standard PVC conduit fittings. Caution should always be
applied when silicon sealants are being used. Only use
recommeded silicon sealants: Dow Corning 732; Dow Corning
1080; Dow Corning 739 Plastic Adhesive; Selleys Window and
Glass Sealant. Any silicon sealant which states “Not for use
with some plastics” definately should not be used. If in doubt
contact your PDL representative.
Proven IP66 Protection
PDL’s 56 Series has been both laboratory tested and field
proven to offer a degree of weather protection to IP66 (see
below).
56 Series socket outlets in particular have a patented selflocking latch feature to ensure that this degree of protection is
maintained when the product is not in use - a feature not
found with comparable product. This means that even when a
56 Series socket outlet is hosed down with a high pressure
hose in industry for example, the socket flap will remain
latched, ensuring its IP66 protection is maintained.
LIQUIDS
Protected against
heavy seas or a
strong jet of water
from all practical
directions.
6
IPx6
SOLIDS
Full Range of Matching Gear
PDL’s 56 Series accessories can be matched throughout a
project with switches, socket outlets and switched socket
combinations, RCD outlets, a range of enclosures and blank
lids, plus the associated plugs. The Series covers single and
three phase accessories, 3-pin to 7-pin 10A to 20A sockets,
3-pin to 5-pin 32A to 50A sockets and 10A to 63A switches.
Modules Make Assembly Simple
Based upon a standard 100 x 100 mm module for all platetype accessories,
PDL’s 56 Series lets you build up any combination from a
simple switch or socket outlet to a full nine-gang switching
station, power outlet centre or custom electrical/electronic
assembly using modules and one of a wide range of matching
enclosures. Matching blank lids can enclose delicate
switchgear or be modified to carry custom panel equipment.
Quick, Easy and Safe Wiring
Completely
protected
against
dust.
6
After years of service exposed to very high UV conditions, it
has become accepted that PDL’s 56 Series offers excellent
protection against UV discolouration and degradation - a
higher degree of protection than comparable products.
Products in the Series feature large capacity terminals, big,
backed-off terminal screws and wherever appropriate, factory
pre-wiring.
IP6x
Page 3
PDL’S 56 Series ... Rated No 1!
With features designed to outperform all other protected accessories
Total IP66 sealing from
conduit entry to plug cable
Non-perishable synthetic gaskets
Screw caps eliminate dirt
Neon indicator option
Clear indication of switch position
Padlock ON/OFF facility
Keylock switch option available
Rotary ON/OFF switch
Captive plate screws
Electrical rating and
specification are clearly displayed
Available in high impact ‘electric grey’ or
chemically resistant
orange and white finishes
Transparent flap clearly
shows pin configuration
18 ratings and pin
configurations to AS3123
Plug locking ring maintains
IP66 protection while in use
High impact resistant UV
stabilised polycarbonate
The New 56 Series Pendant Enclosure
Socket cover snaps shut automatically
and locks to provide IP66 protection
Modular system for 1 to 9 gang arrangements
Chemical Resistance
Chemical Compatibility
56 Series
Grey
56 Series
Valox
PDL
Enclosures
PBTA
ABS
Chemical Compatibility
56 Series
Grey
56 Series
Valox
PDL
Enclosures
PBTA
ABS
Acids
Hydrochloric Acid (10%)
A
A
A
A
A
Brake Fluid
D
A
N/T
A
C
Sulphuric Acid (10%)
A
A
A
A
B
Regular Petrol
D
A
A
A
D
Acetic Acid (10%)
C
A
A
A
D
Premium Petrol
D
A
A
N/T
D
C
A
A
B
N/T
Sodium Hydroxide
C
A
A
B
A
Salts
Ammonium Hydroxide
D
C
B
C
B
Ethyl Alcohol
B
A
A
A
C
Methyl Alcohol
B
B
A
A
C
Mechanical and Thermal Properties
Outdoor Use -
Bases
Potassium Hydroxide
Organic Solvents
Isopropyl Alcohol
Unleaded Petrol
D
A
A
A
D
Diesel Fuel
D
A
A
N/T
D
Zinc Chloride (10%)
B
A
B
A
B
Calcium Chloride (10%)
B
A
B
A
B
Sodium Chloride (5%)
B
A
B
A
A
A
A
D
D
B
A
A
A
D
Heptane
N/T
A
N/T
N/T
N/T
Acetone
D
D
D
D
D
Outdoor Use -
Methylethylketone
D
D
D
D
D
colour properties
B
B
mechanical properties
Ethyl Acetate
N/T
D
N/T
N/T
D
Indoor Use
A
A
A
A
A
Methylene Chloride
N/T
D
N/T
N/T
N/T
Light Weight
A
A
A
A
A
Ethylene Glycol
N/T
A
N/T
N/T
N/T
High Rigidty
B
B
Impact Resistance
A
A
C
A
B
Automotive Related Environments
Motor Oil
C
A
N/T
A
C
Glow Wire Test (GWT)
Transmission Fluid
C
A
N/T
A
C
UV Deterioration
Power Steering Fluid
C
A
N/T
A
C
Ball Pressure Test
Page 4
C
850oC 750oC 850oC 960oC 960oC
A
B
125oC 125oC
A
A
C
75oC
125oC
90oC
Contents
Switches to IP66
250V Switches
500V Switches
Auxiliary Contacts for 56SW350/2 and 56SW363/2
500V KG Switches for use with Extra Poles
8
10
11
12
Control Switches
Changeover and Forward/Reverse Switches IP66
Time Switches
Momentary Contact Switches IP66
Sunset Switch
Remote Contactor
Time Delay
Socket Configurations
13
14
14
15
15
16
18
Socket Outlets
110 – 250V Socket Outlets
500V Socket Outlets
Chemically-Resistant White 56 Series
CEE17 Socket Outlets
19
20
21
Combination Switched Sockets
110 – 250V Combination Switched Sockets
500V Combination Switched Sockets
This table is a guide only. Performance of product in a particular
environment will be affected by a wide variety of factors, of
which chemical compatibility is only one. End users should test
for their particular environment.
Ratings
A – Excellent
Compatible, no problems expected from the
use of the chemical with this part.
B – Good
Acceptable, minimal loss of chemical
properties after prolonged exposure.
C – Fair
Marginally compatible, extended use of the
chemical may cause deterioration and
cracking of the part.
D – Poor
Incompatible. Do not recommend the use of
the chemical with this part.
N/T – Not Tested
22
24
RCD Protected Outlets
26
Plug Configurations
28
Appliance Inlets
29
Plugs
250V Plugs
30
500V Plugs
31
Cord Connectors
33
Pendant Outlet Kits
34
DIN Rail Covers
34
Module Mounting Lids
34
Lids
35
Enclosures
36
Pendant Enclosures
38
Flush Surrounds
38
D.O.L. Motorstarters
39
Accessories
43
Page 5
The great features of PDL’s
RCD have just doubled
PDL has expanded its
Powerguard RCD range
with double outlets
Cat 695RCD-30
Features
• Unit remains latched
in loss of voltage
situations - doesn’t
need to be reset.
• Mechanical indicator
shows whether the
RCD is latched or
has been tripped.
• Amber neon indicator
for power available.
• Large clearly-labelled
terminals for input
and output.
• Double pole
switching protects
against faulty wiring.
• 10mA and 30mA
options available.
• Rated 20 amps allows
looping of sockets downstream in the same circuit.
PDL Electrical Products are available through electrical wholesalers New Zealand wide. Visit our website www.pdl.co.nz
PDL Electrical Products are designed and engineered to ISO 9001. Freecall 0800 652 999. Freefax 0800 101 152. Email: enquiry@pdl.co.nz
PDL is a brand of Schneider Electric
Rated the best for the worst
electrical conditions
PDL 56 SERIES
PDL’s 56 Series is the proven,
watertight solution for tough
industrial environments.
Check these features...
• Dustproof and
waterproof to IP66.
• Manufactured from
high impact, grey
polycarbonate
as standard.
• Maximum UV
resistance.
• 95x95mm plate
module for up to
nine gang
combinations.
• One-piece,
internally wired
combination
switched sockets.
• Sockets available
with 30mA RCD
protection.
• Chemically-resistant
orange and white
versions available.
• Switches carry AC23A
and AC3 motor ratings
to EN60974, making
them suitable for switching
DOL motors.
PDL Electrical Products are available through electrical wholesalers New Zealand wide. Visit our website www.pdl.co.nz
PDL Electrical Products are designed and engineered to ISO 9001. Freecall 0800 652 999. Freefax 0800 101 152. Email: enquiry@pdl.co.nz
PDL is a brand of Schneider Electric
Switches to IP66
56SWK110
56SW110
56SW216N
250V Switches
PDL’s comprehensive range of 250V
Switches ensures that there is always a
suitable switch available for every single
phase application.
Dimensional
Drawings
Options available:
NEON
specify “N” after catalogue number
eg: 56SW110N
KEYLOCK
specify “K” or 2K after “56SW” eg:
56SWK220
Keylock versions of all PDL switches
except the Forward/Reverse,
Changeover switches and KG series
switches are available.
Key removable in the OFF position
only – Specify K after the series
number eg: 56SWK110.
Key removable in the OFF and ON
positions – Specify 2K after the
series number eg: 56SW2K110.
Common keyed barrels and keys are
available to order for all 56 Series
Keylock versions.
YELLOW COVER/RED KNOB for isolating
switches – Specify YELLOW
after catalogue number eg: 56SW363/2 YELLOW
94mm
16A
500V
SINGLE PHASE
50Hz
IP 66
CAT No.
56 SO 110N
94mm
28mm
20mm
56 SW 110N
Wiring
Diagrams
Combinations of the above are available.
A
Cat No
56SW110
56SW110/2
56SW110/2I
56SW210
Volts
250
250
250
250
Amps
10
10
10
10
Wiring Diagram
A
B
C
D
Description
1 way
2 way
Intermediate
1 way
Single Pole
Single Pole
Changeover
Double Pole
0.75
0.75
0.75
0.75
6
6
6
6
10AX
10AX
10AX
10AX
M50
M50
M40
M40
8AX
8AX
8AX
8AX
Rated Operational Voltage
Ue (~50Hz)
B
1 way
Single Pole
2 way
Single Pole
Rated Thermal Current
Enclosed
Cable Cross Sections
Min
Solid or Stranded mm2 Max
D
C
1 way
Double Pole
Intermediate
Changeover
Switch Ratings
AS3133
250V
Switch Ratings
Fluorescent
E
1 way
Single Pole
BS3676
250V
F
Page 8
1 way
Double Pole
Switches to IP66
56SW232
56SW2KC110N
56SW250
Wiring
Diagrams
Cat No
56SW116
56SW216
56SW120
56SW220
56SW132
56SW232
56SW150 56SW250
250
250
250
250
250
250
Rated Operational Voltage
Ue (~50Hz)
A
1 way
Single Pole
Volts 250
Enclosed
Amps 16
Wiring Diagrams
E
Decription
1 way
Double Pole
16
20
20
32
32
50
50
F
A
B
C
D
E
F
1 way
1 way
1 way
1 way
1 way
1 way
1 way
1 way
Single
Double
Single
Double
Single
Double
Single
Double
Pole
B
250
Rated Thermal Current
Pole
Pole
Pole
Pole
Pole
Pole
Pole
Cable Cross Sections Min 0.75
1
1
1
1
1
6
6
Solid or Stranded mm2 Max 6
16
16
16
16
16
35
35
AS3133 16AX
16AX
20AX
20AX
32AX
32AX
50AX
50AX
250V M120
M120
M150
M150
M180
M180
M250
M250
16AX
20AX
20AX
32AX
32AX
---
---
5.5
Switch Ratings
Switch Ratings
Fluorescent
C
1 way
Single Pole
1 way
Double Pole
E
1 way
Single Pole
F
1 way
Double Pole
250V 16AX
Switch Ratings EN 60947-3
AC23A
AC3
D
BS3676
240V
240V
kW 2.2
2.2
3.0
3.0
4.0
4.0
5.5
Amps 15
15
21
21
28
28
35
35
kW 1.5
1.5
2.2
2.2
3.0
3.0
4.0
4.0
Amps 11
11
15
15
21
21
28
28
Page 9
Switches to IP66
56SW320
56SW332
56SW363/2
Dimensional
Drawings
500V Switches
All of PDL’s extensive range of 500V
Options available:
Switches are fully motor rated to AC23A
NEON
specify “N” after catalogue
94mm
number eg: 56SW310N
and AC3 making them suitable for
switching the harshest loads likely to be
KEYLOCK specify “K” or 2K after
94mm
“56SW” eg: 56SWK332
found in industry.
Cat No
56SW310
56SW316
56SW320
56SW332
Volts
500
500
500
500
Volts
660
660
660
660
kV
2.5
2.5
2.5
2.5
28mm
Rated Operational Voltage
Ue (~50Hz)
Rated Insulation Voltage
Ui (~50Hz)
Rate Impulse Withstand Voltage
Uimp
20mm
56 SW 332
Rated Thermal Current
Enclosed
10
16
20
32
Rated Duty
Amps
Uninterrupted
Uninterrupted
Uninterrupted
Uninterrupted
Description
3 Pole
3 Pole
3 Pole
3 Pole
94mm
20A
500V
THREE PHASE
50Hz
IP 66
Switch Disconnector
CAT No.
Cable Cross Section
Min
1
1
1
1
Solid or Stranded mm2
Max
16
16
16
16
M100
M120
M150
M180
56 SWK 320
94mm
SWITCH RATINGS
AS3133 500V
EN 60947/3
20mm
Switching of Resistance Loads
28mm
Including a Moderate Overload
AC21A
415V
Amps
10
16
20
32
Switching of Motor Loads or
other Inductive Loads
kW
5.5
7.5
11
15
AC23A
Amps
11
15
21
28
Switching of Squirrel Cage Motors
kW
4.0
5.5
7.5
11
AC3
Amps
8.5
11
15
21
Amps
10
16
20
32
1 second
kA
1.5
1.5
1.5
1.5
Rated Short Circuit Making Capacity
kAp
1.0
1.0
1.0
1.0
415V
415V
Switching of DC Resistive Loads
DC21A
32V
Rated Short Time Withstand Current
Page 10
20mm
56 SWK 320
Switches to IP66
Dimensional
Drawings
94mm
Cat No
56SW340
56SW350
56SW350/2
56SW363
56SW363/2
40
50
63
63
63
Rated Duty
Uninterrupted
Uninterrupted Uninterrupted
Uninterrupted
Uninterrupted
Description
3 Pole
3 Pole
3 Pole
3 Pole
3 Pole
Min
6
6
6
6
6
Max
35
35
35
35
35
M200
M250
M250
M300
M300
40
50
50
63
63
22
Rated Thermal Current
Enclosed
Amps
Switch Disconnector
Cable Cross Section
Solid or Stranded
AC21A 416V 63A
50Hz
CAT No.
mm2
IP 66
56 SW363/2
SWITCH RATINGS
190mm
AS3133
500V
EN 60947/3
Switching of Resistance Loads
Including a Moderate Overload
AC21A
415V
Amps
Switching of Motor Loads or
other Inductive Loads
18mm
28mm
18.5
18.5
18.5
22
Amps
35
35
35
45
45
kW
15
15
15
18.5
18.5
Amps
28
28
28
35
35
Amps
40
50
50
63
63
kA
2.5
1.5
1.5
2.5
1.5
Rated Short Circuit Making Capacity kAp
2.5
2.1
2.1
2.5
2.1
AC23A
kW
415V
Switching of Squirrel Cage Motors
AC3
415V
Switching of DC Resistive Loads
DC21A
32V
Rated Short Time Withstand Current
1 second
20mm
56 SW 363/2
Auxiliary Contacts for 56SW350/2 and 56SW363/2
PDL offer two clip-on auxiliary contacts
clipped to the top of the switches and
suitable for use with the 56SW350/2 and
are suitable for control applications such
56SW363/2. Both auxiliaries are easily
as PLCs.
Cat No
56SW01
56SW15
Volts
125 or 250
250
Amps
0.1 at 125V
15
Rated Operational Voltage
Ue (~50Hz)
Rated Thermal Current
Enclosed
0.05 at 250V
Terminal Type
Screw
Description
Single Pole
Single Pole
Contacts
1 N/O & 1 N/C
1 N/O & 1 N/C
Contact Type
Gold
Nickel/Silver
Page 11
Screw
500V KG Switches
56SW420/KG
56SW432/2KG
56SW332/KG
500V KG Switches
PDL has utilised the proven Kraus and
switches are not available in NEON or
Naimer KG Series of switches in this
KEYLOCK versions.
range of 56 Series switches. 56SW320/
Both 56SW420KG and 56SW432KG are
KG and 56SW332/KG suit 56E1 enclo-
available to suit 56E1 and 56E2 enclo-
sures, 56SW340/KG and 56SW363/KG a
sures. To order specify 56W4##/2KG for
require 56E2 enclosure to provide
a 56E2 enclosure.
Dimensional
Drawings
94mm
AC21A
690V 32A
50Hz
IP 66
CAT No. 56 SW 332 / KG
94mm
adequate wiring room. Note: KG
28mm
Cat No
56SW320/KG
56SW420/KG
56SW332/KG
56SW432/KG
56SW340/KG
56SW363/KG
500
500
500
500
500
500
Rated Operational Voltage
Ue (~50Hz)
Volts
40mm
Rated Insulation Voltage
Ui (~50Hz)
Volts
660
660
660
660
660
660
Amps
20
20
32
32
40
63
A
Rated Thermal Current
Enclosed
Description
A
B
A
B
A
Cable Cross Section
Min
1
1
1
1
6
6
Solid or Stranded mm2
Max
6
6
6
6
10
10
Wiring
Diagrams
Utilisation Categories
Switching of Resistive Loads
A
3 Pole
B
4 Pole
Including a Moderate Overload
AC21A
415V
Amps
20
20
32
32
40
63
kW
7.5
7.5
11
11
15
22
Amps
5.5
5.5
7.5
7.5
11
18.5
kA
1.5
1.5
1.5
1.5
1.5
1.5
kAp
22
22
22
22
50
50
Switching of Motor Loads or
Other Inductive Loads
AC 23A
415V
Switching of Squirrel
Cage Motors
AC3
415V
Rated Short Time Withstand
Current 1 Second
Rated Short Circuit
Making Capacity
Page 12
56 SW 332/KG
Control Switches
56SW320F/R
Dimensional
Drawings
56SW120C/O
Changeover and Forward/Reverse Switches IP66
42mm
94mm
A range of IP66 Changeover and
application. Cover markings possible
Forward/Reverse switches ideal for
include:
generators, auto/manual systems, fans,
94mm
I, II
FWD, REV
MAN, AUTO
doors and conveyors. Each switch
AUX, MAIN
AC3 5.5kW 500V
1-3 PH REVERSING
Ithe 20A
IP 66
comes with a sheet of adhesive labels
CAT No. 56 SW 320 F/R
30mm
56 SW 320F/R
94mm
42mm
for the end user to select the appropri-
Control Switches are supplied as a standard
ate cover markings for the specific
100 x 100 one gang module less enclosure.
Cat No
94mm
UP, DOWN
56SW320F/R
56SW120C/O
56SW220C/O
56SW320C/O
56SW332C/O
500
500
500
500
500
Rated Operational Voltage
Ue (~50Hz) Volts
AC3 5.5kW 500V
3P CHANGEOVER
Ithe 20A
IP 66
CAT No. 56 SW 320 C/O
Rated Thermal Current
30mm
56 SW 320C/O
Enclosed
Wiring
Diagrams
N
Note: Fit wire link between (Red)
L1
terminals 1 & 5
1 3 5 7
SINGLE PHASE
THREE PHASE
2 4 6 10
2 4 6 10
Run
M
M1 M1
M
Start
1 Pole Changeover
Solid or Stranded
1
0
3
5
0
7
mm2
6
D
10
2 x 2.5
2 x 2.5
2 x 2.5
2 x 2.5
2 x 2.5
500V
Amps
20
20
20
20
32
7.5
15
2.5
2.5
2.5
4
5.5
11
Switching of Motor Loads
or Other Highly Inductive Loads
3 Phase
kW
7.5
1 Phase
kW
2.5
AC3
415V
3 Phase
kW
5.5
240V
1 Phase
kW
2.2
2.2
2.2
2.2
4
kA
5
5
5
5
5
Rated Short Circuit
Making Capacity
3 Pole Changeover
2
32
D
Switching of Squirrel Cage Motors
2 Pole Changeover
6
20
D
Including a Moderate Overload
AC21A
240V
3
2
20
C
Switching and Resistive Loads
0
B
20
B
Utilisation Categories
AC23A 415V
1
2
C
(Yellow)(Blue)
L2
L3
1 3 5 7
M1
A
20
A
Cable Cross Section
Single or Three Phase Reversing
A/P
Amps
Wiring Diagram
1
0
3
5
0
7
9
0
11
Page 13
Time Switches
56TC24HB
56PB2G/R
PDL 56 Series Time Switches feature 24
situations. These timers are supplied in
hour and 7 day timers for the automatic
a standard one gang 56 Series cover for
time switching of process control
use with 56 Series deep enclosures.
equipment, heaters, pumps and lighting
Supplied with a padlocking clip to enable
Dimensional
Drawings
94mm
20A
the flap to be locked closed.
13
18 17 16 15
19
20
24 Hour
7 Day
7 Day
24 Hour and
Quartz
Synchronous
Quartz
7 Day Digital
230 – 240
230 – 240
230 – 240
230 – 240
230 – 240
9
24 Hour
Synchronous
28mm
Rated Operational Voltage
Ue (~50Hz)
94mm
2
Description
34 23 22 21
56TCU
3
56TC7DB
9
4
56TC7D
5
56TC24HB
8
12
6
56TC24H
9
7
Cat No
IP 66
56 TC24H
11 10
12
14
in domestic, commercial and industrial
230/240V
30mA I n
50Hz
CAT No.
1
56TCU
Volts
Switching Capacity
Maximum Resistive
Amps
16
16
16
16
16
Maximum Inductive
Amps
8
8
8
8
2.5
Maximum Incandescent Watts
1350
1350
1350
1350
1000
Minimum Switching Load mA
100
100
100
100
100
Accuracy
Mains
± 2.5 Sec
Mains
± 2.5 Sec
± 2.5 Sec
Synchronized
Per Day
Sychronized
Running Reserve
150 Hours
Minimum Switching Time
56 TC24H
30mm
Per Day
Per Day
150 Hours
150 Hours
15 Min
15 Min
2 Hours
2 Hours
1 Minute
Cable Cross Section
Min
0.75
0.75
0.75
0.75
0.75
Solid or Stranded mm2
Max
6
6
6
6
6
95mm
20A
230/240V
ACR 2A 415V
50Hz
IP 66
CAT No.
56 PB1/R
95mm
Momentary Contact Switches IP66
28mm
PDL 56 Series push
button switches can be
used for remote switch-
Cat No
56PB1/G
Ue (~50Hz)
Enclosed
motor starters. These
Diagrams
Volts 250
250
250
16
16
56 PB1/R
Amps 16
1 N/O and 1 N/C
Momentary
Contact
Push Button
1 x Green
1 x Red
switches are supplied in
gang cover for use with
56PB2G/R
Rated Thermal Current
ing of control gear or
a standard 56 Series one
56PB1/R
Rated Operational Voltage
Push Button Colour
Cover Markings
Cable Cross Section
Start/Stop
Min 0.75
20mm
2 N/O and 2 N/C
Momentary
Contact
Push Button
1x Green, 1 x Red
0.75
0.75
6
6
95m
20A
CAT No.
56 Series enclosures.
Solid or Stranded mm2 Max 6
28mm
230/240V
ACR 2A 415V
50Hz
IP 66
56 PB2G/R
Utilisation Category
95mm
Feed Control of Contactors
START
STOP
Electro-Magnets and Valves
AC11 250V
Amps 4
4
4
415V
Amps 2
2
2
Page 14
20mm
56 PB2G/R
20mm
Sunset Switch
56SS10
Dimensional
Drawings
95mm
20A
PDL 56 Series Sunset Switch is a photo-
lighting, display lighting and security
electric light sensor designed to switch a
lighting. The Sunset Switch is supplied
load on at dusk and off at dawn. The unit
either with an enclosure (56SS10WE) or
has a built in time delay to reduce nuisance
less enclosure (56SS10) for use with
switching from brief exposure to lights or
any 56 Series enclosure combination.
shadows.
Both models include a black daylight
Ideal for controlling car park and walkway
test cover.
230/240V
SINGLE PHASE
50Hz
IP 66
CAT No.
56RC230
56 SS10
95mm
Cat No
28mm
56SS10
Rated Operational
Voltage Ue (~50Hz)
Volts 230 – 240
Switching Capacity
Maximum Resistive
Amps 10
Maximum Incandescent Watts 2000
56 SS10
28mm
Maximum Inductive
Amps 8
Switching Light Level (Lux)
Factory Preset to 50 Lux
Cable Cross Sections
Min 0.75
Solid or Stranded mm2
Max 6
Remote Contactor
95mm
20A
230/240V
3 POLE +1 N/O Aux
230V COIL
IP 66
CAT No.
56 RC 230
95mm
Cat No
56RC230
PDL’s 56 RC230 incorporates a Kraus
Rated Operational
Voltage Ue (~50Hz)
Volts
230
Amps
16
Enclosed
Description
Coil
standard 56 Series single lid making it
Electromagnetic Contactor
compatible with standard 56 Series
3 Pole + 1 N/O Auxiliary
enclosures for those applications where
230V 50Hz AC
56 RC230
28mm
and Naimer contactor fitted to a
Rated Thermal Current
28mm
Other Coil Voltages
installation of a remote contactor may
Available on Request
be easier or more convenient.
Operational Ratings
Resistance
16A 3800W Per Pole
Incandescent
12A 2800W Per Pole
Fluorescent
1600W Per Pole
with 0.9pF Correction
AC3
230V
Single Phase
1.5kW Per Pole
AC3
400V
Three Phase
5.5kW Per Pole
Cable Cross Section
Min
0.75
Solid or Stranded mm2 Max
4
IP Rating
IP66
Page 15
Time Delay
56TD
56TD120P
PDL 56 Series Time Delay allows a load
PDL 56 Series preset countdown timers
to be switched for a preset time interval.
offer one touch activation. Pushing the
Ideal for controlling lighting and heating
‘ON’ button during the timing sequence
in commercial and industrial situations.
restarts the timer. The ‘OFF’ button is
Time Delay is supplied in a standard one
included for override of the timing
Dimensional
Drawings
95mm
20A
gang cover for use with any 56 Series
230/240V
TIME DELAY
50Hz
IP 66
CAT No.
56 TD
sequence - this also resets the timer.
95mm
enclosure combination.
Cat No
56TD
Description
56TD5P
56TD15P
56TD30P
56TD60P
56TD120P
Preset
Preset
Preset
Preset
Adjustable electronic
Preset
time delay for switching
Countdown Countdown Countdown Countdown Countdown
load for a preset time
Timer
Timer
Timer
Timer
Timer
230 – 240
230 – 240
230 – 240
230 – 240
230 – 240
230 – 240
28mm
Rated Operational
Voltage (~50Hz)
Volts
56 TD
35mm
Switching Capacity
Maximum Resistive
Amps
Maximum Incandescent Watts
Maximum Inductive
Amps
10
20
20
20
20
30 mins
20
2000
6
Time Selection Range
1 second to 31.5 hours
5 mins
15 mins
60 mins
120 mins
Push Button Colour
Blue
Green - ON
Green - ON Green - ON
Green - ON
Green - ON
Blue - OFF
Blue - OFF
Blue - OFF
Blue - OFF
Blue - OFF
Cable Cross Section
Min
0.75
1.0
1.0
1.0
1.0
1.0
Solid or Stranded mm2
Max
6
10.0
10.0
10.0
10.0
10.0
Page 16
When you specify
there’s a catch
PDL,
PDL’s 56 series patented self-locking
catch ensures the highest degree of
protection is maintained when the
product is not in use – a feature
not found with comparable
protected industrial accessories.
The IP66 rating requires that
even when a socket outlet
in an industrial installation
is hosed down with a high
pressure hose, the socket
flap will remain closed.
It is also completely
protected against dust.
PDL has a proven
record in quality and
reliability in servicing
New Zealand with its
electrical accessories
and is the only
manufacturer to
hold both Telarc
registration and
ASTA certification
for its quality
management systems.
PDL 56 Series is
designed and
engineered to ISO 9001,
and manufactured to
ISO 9002.
So when it comes to your
industrial electrical installation
options, there is only one name
you need to know, PDL 56 Series.
PDL Electrical Products are available through electrical wholesalers New Zealand wide. Visit our website www.pdl.co.nz
PDL Electrical Products are designed and engineered to ISO 9001. Freecall 0800 652 999. Freefax 0800 101 152. Email: enquiry@pdl.co.nz
PDL is a brand of Schneider Electric
Socket Configurations
240 Volt
240V
3 pin
10A Aust/NZ
A
15A Aust/NZ
10A Aust/NZ
C
B
20A Aust/NZ
13A British
E
D
20A
F
32A
G
500 Volt
500V
500V
500V
500V
4 pin
H
16A
O
16A
U
16A
I
“K” 16A
J
20A
K
32A
L
35A
M
40A
N
50A
R
35A
S
40A
T
50A
f
32A ✱
5 pin
P
20A
Q
32A
6 pin
7 pin
V
16A
W
20A
CEE17
110V &
250V
3 pin
a
400V
400V
16A 110V
b
16A 250V
c
32A 250V
d
16A
e
32A
4 pin
5 pin
g
16A
h
32A
✱ 3h earth configuration for container applications.
Page 18
Socket Outlets
56SO320
56SO310/2
Socket
Configurations
56SO316/110
110 – 250V Socket Outlets
PDL 56 Series 110 – 250V Socket Outlets
automatic IP66 seal. The flap is
feature a patented transparent hinged flap
transparent so the pin configuration can
which snaps shut and locks over the socket
be readily identified without opening.
when the plug is withdrawn, forming an
Cat No
A
B
56SO310
56SO310/2
56SO310R
56SO315
56SO320F
Volts
250
250
250
250
250
Amps
10
10
10
15
20
3
3
3
3
3
NZ / Aust
NZ / Aust
Rated Operational
Voltage Ue (~50Hz)
Rated Thermal Current
Enclosed
Number of Socket Pins
C
D
(Including Earth
)
Description
E
F
NZ/Aust
Round Earth
3 Large Flat
A
A
C
B
E
Cable Cross Sections
0.75
0.75
0.75
0.75
0.75
Min
mm2
Max
IP Rating
Cat No
a
NZ / Aust
Socket Configuration refer Pg 18
Solid or Stranded
G
NZ/Aust
Twin Socket
Rated Operational
Volts
10
10
10
10
10
IP66
IP66
IP66
IP66
IP66
56SO313
56SO316/110
56SO316/240
56SO320
56SO332
230
110
230
250
250
Yellow
Blue
13
16
16
20
32
3
3
3
3
3
BS
CEE17 - 4h
CEE17 - 6h
AS3123
AS3123
G
Voltage Ue (~50Hz)
Rated Thermal Current
Enclosed
b
Amps
Number of Socket Pins
(Including Earth
)
Description
Square
Pin Outlet
Socket Configuration refer Pg 18
D
a
b
F
Cable Cross Sections
0.75
0.75
0.75
1.0
1.0
Solid or Stranded mm2 Max
10
6
6
10
16
IP Rating
IP66
IP66 No Plug
IP66 No Plug
IP66
IP66
IP44 with Plug
IP44 with Plug
Min
Page 19
500V Socket Outlets
56SO416K
56SO420
56SO716
Socket units are supplied as a standard 100
enclosures or combining with other
x 100 one gang module for use with 56E1
accessories in a larger enclosure.
Dimensional
Drawings
94mm
Cat No
56SO416 56SO416K 56SO420 56SO432 56SO435 56SO440 56SO450
16A
500V
THREE PHASE
50Hz
IP 66
CAT No.
56 SO 416
Rated Operational
Voltage Ue (~50Hz)
Volts
500
500
500
500
500
500
500
16
20
32
35
40
50
4
4
4
4
4
4
4
Socket Configuration refer Pg 18 H
I
J
K
L
M
N
Cable Cross Section
1
1
1
1
1
4
94mm
Rated Thermal Current
Enclosed
Amps 16
Number of Socket Pins
(Including Earth
Solid or Stranded
28mm
)
Min
mm2
IP rating
1
Max 10
IP66
10
10
16
16
16
25
IP66
IP66
IP66
IP66
IP66
IP66
30mm
Cat No
56SO516 56SO520 56SO532 56SO535 56SO540 56SO550 56SO616 56SO716 56SO720
Rated Operational
Voltage Ue (~50Hz)
Volts 500
500
500
500
500
500
500
500
500
20
32
35
40
50
16
16
20
Rated Thermal Current
Enclosed
Amps 16
Number of Socket Pins
(Including Earth
5
5
5
5
5
5
6
7
7
Socket Configuration refer Pg 18 O
)
P
Q
R
S
T
U
V
W
Cable Cross Section
1
1
1
1
1
4
1
1
Solid or Stranded mm2 Max 10
Min 1
10
16
16
16
25
10
10
10
IP rating
IP66
IP66
IP66
IP66
IP66
IP66
IP66
IP66
IP66
Page 20
56 SO 416
500V Socket Outlets
56SO432 CEE
Dimensional
Drawings
94mm
56SO432C CEE
CEE17 Socket Outlets
Where socket outlets to the European
CEE socket requires a 56 Series switch,
CEE17 standard are required, the 56 Series
they should be fitted to a horizontally
CEE sockets are available and suit standard
mounted 56E2 enclosure.
56 Series enclosures. Where a 56 Series
IP57
3P +
50Hz
32A – 6h/400V ~
CAT No.
94mm
56 SO 432 CEE
Cat No
56SO316 CEE 56SO332 CEE
56SO416 CEE
56SO432 CEE
56SO432C CEE* 56SO516 CEE
56SO532 CEE
Volts
230
230
400
400
400
400
400
Amps
16
32
16
32
32
16
32
5
Rated Operational Voltage
Ue (~50Hz)
66mm
Rated Thermal Current
Enclosed
Number of Socket Pins
(Including Earth
30mm
56 SO 432 CEE
3
3
4
4
4
5
Socket Configuration refer Pg 18 b
)
c
d
e
f
g
h
Earth Pin Position
6H
6H
6H
6H
3H
6H
6H
Blue
Blue
Red
Red
Red
Red
Red
1.5
2.5
1.5
2.5
2.5
1.5
2.5
Solid or Stranded mm2 Max
4
10
4
10
10
4
10
IP rating
IP57
IP57
IP57
IP57
IP57
IP57
IP57
Frequency Colour
Cable Cross Section
Min
* 56SO432C CEE specifically for international container equipment.
Page 21
Combination Switched Sockets
56CV310
56CV315
56CV313
The 56 Series includes an extensive
keylock type, eg: cat no. 56CVK310). For
range of one piece combination
NEON indicator option add “N” after
Switched Sockets. Optional keylocking
catalogue number.
Socket
Configurations
OFF facility (quote “CVK” when ordering
110 – 250V Combination Switched Sockets
Cat No
56CV310
56CV310R
56CV320F
56CV315
56CV313
250
250
250
250
250
A
B
C
D
Rated Operational Voltage
Ue (~50Hz)
Volts
Rated Thermal Current
Enclosed
Amps
Description
10
10
13
16
20
Switched
Switched
Switched
Switched
Switched
NZ / Aust.
NZ / Aust.
NZ / Aust.
British
NZ / Aust.
Socket
Socket
Socket
Square Pin
Socket
Round Earth
SWITCH
Socket
3 Large Flat Pin
1 Way
1 Way
1 Way
1 Way
1 Way
Double Pole
Double Pole
Double Pole
Double Pole
Double Pole
Amps
10AX M50
20AX M150
16AX M120
16AX M120
20AX M150
Amps
15
15
15
15
21
kW
2.2
2.2
2.2
2.2
3.0
Min
0.75
0.75
1.0
1.0
1.0
6
6
16
16
16
3
3
3
3
3
A
C
E
B
D
1.0
1.0
1.0
1.0
1.0
Description
Utilisation Category
AS3133
AC23A
250V
240V
Cable Cross Section
Solid or Stranded mm2 Max
SOCKET
Number of Socket Pins
Including (Earth
)
Socket Configuration
Cable Cross Section
Solid or Stranded
IP Rating
Min
mm2 Max
10
10
10
10
10
IP66
IP66
IP66
IP66
IP66
Page 22
E
Combination Switched Sockets
56CV316/110
56CV316/240
Socket
Configurations
56CV332
Cat No
56CV316/110
56CV316/240
56CV320
56CV332
110
250
250
250
Rated Operational Voltage
Ue (~50Hz)
Volts
Rated Thermal Current
Enclosed
Amps
Description
G
F
SWITCH
Description
16
16
20
32
Switched
Switched
Switched
Switched
CEE17-4h
CEE17-4h
AS3123
AS3123
Socket
Socket
Socket
Socket
(Yellow)
(Blue)
1 Way
1 Way
1 Way
1 Way
Double Pole
Double Pole
Double Pole
Double Pole
Utilisation Category
a
b
AS3133
250V
Amps
16AX M120
16AX M120
20AX M150
32AX M180
AC23A
240V
Amps
15
15
21
28
4.0
kW
2.2
2.2
3.0
Min
1.0
1.0
1.0
1.0
Solid or Stranded mm2 Max
16
16
16
16
3
3
3
3
a
b
F
G
Min
1.0
1.0
1.0
1.0
Max
6
6
10
16
IP66 without
IP66 without
IP66
IP66
plug; IP44
plug; IP44
with plug
with plug
Cable Cross Section
SOCKET
Number of Socket Pins
Including (Earth
)
Socket Configuration
Cable Cross Section
solid or stranded
IP Rating
mm2
Page 23
Combination Switched Sockets
56CV432
Interlock feature (seen from rear)
500V Combination Switched Sockets
All 500V Switched Sockets rated 32A
Optional keylocking OFF facility (quote
and above have an internal interlocking
“CVK” when ordering keylock type, eg: cat
feature (plugs cannot be withdrawn or
no. 56CVK432).
inserted when the switch is in the ON
For NEON indicator option add “N” after
position) with this feature available on
catalogue number.
16A and 20A units on request.
Cat No
56CV416 56CV416K 56CV420 56CV432
56CV435
56CV440 56CV450
500
500
500
500
Socket
Configurations
H
I
J
K
L
M
N
O
Rated Operational
Voltage Ue (~50Hz)
Volts
500
500
500
Rated Thermal Current
Enclosed
Amps
SWITCH Description
16
16
20
32
35
40
50
3 Pole
3 Pole
3 Pole
3 Pole
3 Pole
3 Pole
3 Pole
16AX
16AX
20AX
32AX
32AX
50AX
50AX
M120
M120
M150
M180
M180
M250
M250
7.5
7.5
11.0
15.0
15.0
18.5
18.5
Utilisation Categories
AS3133
AC23A
500V
Amps
415V
kW
Amps
Cable Cross Sections
Min
Solid or Stranded mm2 Max
15
15
21
28
28
35
35
1
1
1
1
1
6
6
16
16
16
16
16
35
35
SOCKET
Number of Socket Pins
(Including Earth
4
4
4
4
4
4
Socket Configuration
)
H
I
J
K
L
M
4
N
IP rating
IP66
IP66
IP66
IP66
IP66
IP66
IP66
Page 24
Combination Switched Sockets
Dimensional
Drawings
Cat No
56CV516 56CV520 56CV532
56CV535
56CV540
56CV550 56CV616
56CV716 56CV720
500
500
500
500
500
Rated Operational
Voltage Ue (~50Hz)
Volts
500
500
500
500
Rated Thermal Current
94mm
Enclosed
Amps
16
20
32
35
40
50
16
16
20
3 Pole
3 Pole
3 Pole
3 Pole
3 Pole
3 Pole
3 Pole
3 Pole
3 Pole
16AX
20AX
32AX
32AX
50AX
50AX
16AX
16AX
20AX
M120
M150
M180
M180
M250
M250
M120
M120
M150
kW
7.5
11.0
15.0
15.0
18.5
18.5
7.5
7.5
11.0
Amps
15
21
28
28
35
35
15
15
21
Cable Cross Sections Min
1
1
1
1
6
6
1
1
1
Solid or Stranded mm2 Max
16
16
16
16
35
35
16
16
16
7
SWITCH Description
Utilisation Categories
AS3133
190mm
AC23A
500V
Amps
415V
SOCKET
Number of Socket Pins
(Including Earth
28mm
30mm
5
5
5
5
5
5
6
7
Socket Configuration refer Pg 18 O
)
P
Q
R
S
T
U
V
W
IP rating
IP66
IP66
IP66
IP66
IP66
IP66
IP66
IP66
IP66
56 CV 532
Page 25
RCD Protected Outlets
56RCD20-30
56ELCB20
56 Series RCD or ELCB protected socket
outlets protect the user against an earth
fault. Both RCD and ELCB models
feature double pole switching and
respond to earth fault in pulsating DC
applications. Over Current Operating
Characteristics curves for the ELCB
models are available on request.
56 Series RCD’s are available with both
latching and non-latching RCD modules.
To order a non-latching product specify
‘A’ in the description (ie. 56ARCD20 or
56C310ARCD).
To order a latching product refer to the
descriptions below.
Protection Module Specifications
(used in all RCD/ELCB products)
RCD
ELCB
230 – 240
120- 240
Residual Current
Residual Current
Device
Device with Overload Protection
Rated Operational
Voltage Ue (~50Hz)
Volts
Description
Max. Thermal Current
Enclosed
Amps
Number of Poles
20
10,16 and 20
2
2
Rated Tripping Current
30mA
30mA
Rated Tripping Time
30mS
100mS
Power Consumption
1.6W at 240V
Cat No
56RCD20-30
56ELCB10
56ELCB16
56ELCB20
230-240
120-240
120-240
120-240
Rated Operational
Voltage Ue (~50Hz)
Volts
Rated Thermal Current
Enclosed
Amps
Description
20
10
16
20
RCD
RCD
RCD
RCD
Module
and 10A
and 16A
and 20A
only
Overload
Overload
Overload
Protection
Protection
Protection
30mA
30mA
30mA
30mA
100mS
RCD MODULE
Rated Tripping Current
Rated Tripping Time
30mS
100mS
100mS
Cable Cross Section
Min
1.0
1.0
1.0
1.0
Solid or Stranded mm2
Max
10
10
10
10
IP66
IP66
IP66
IP66
IP Rating
Page 26
RCD Protected Outlets
56C310RCD-30
56C313ARCD
Dimensional
Drawings
Cat No
56C310RCD-30 56C313ARCD 56C316RCD-30
56C320RCD-30 56C310ELCB
56C316ELCB
56C320ELCB
240
240
240
240
240
240
20
Rated Operational
Voltage Ue (~50Hz)
Volts
240
Rated Thermal Current
94mm
Enclosed
230/240V a.c.
30mA
56C320RCD-30
I n
Amps
10
13
16
10
16
20
RCD
RCD
RCD Protected RCD
RCD
RCD
RCD
Protected
Protected
CEE17
Protected
and Overload and Overload
and Overload
10A Socket
BS Socket
Socket
20A
Protected
Protected
Protected
(Blue)
Socket
10A Socket
16A Socket
20A Socket
Residual Current Device
56 RCD
RED
BLACK
ON
OFF
Description
RESET
TEST
TEST BEFORE USE.
DO NOT USE
IF TEST FAILS
190mm
10A
SINGLE PHASE
50Hz
IP 66
CAT No. 56 C 310RCD-30
RCD MODULE
Rated Tripping Current
30mA
30mA
30mA
30mA
30mA
30mA
30mA
Rated Tripping Time
30mS
30mS
30mS
30mS
100mS
100mS
100mS
3
3
3
3
3
3
3
Socket Configuration refer Pg 18 A
D
a
F
A
a
F
Cable Cross Section
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Soild 0r Stranded mm2 Max
6
10
6
10
6
6
6
IP Rating
IP66
IP66
IP66
IP66
IP66
IP66
IP66
SOCKET
Number of Socket Pins
28mm
(Including Earth
30mm
)
Min
56 C310RCD-30
Page 27
Plug Configurations
240 Volt
240V
3 pin
10A Aust/NZ
A
32A
20A
13A British
15A Aust/NZ
E
C
B
F
500 Volt
500V
500V
500V
500V
4 pin
G
16A
L
16A
R
16A
S
16A
Q
16A
H
20A
I
32A
U
35A
N
32A
V
35A
J
40A
K
O
40A
P
50A
5 pin
M
20A
T
20A
6 pin
7 pin
Page 28
50A
Appliance Inlets
56AI310
Dimensional
Drawings
94mm
10A
250V
SINGLE PHASE
50Hz
IP 66
CAT No.
56 AI 310
56AI532
PDL’s Appliance Inlets can be used with
Note: 56AI310 fits on a standard 56E1
any appropriately rated cord connector
enclosure.
maintaining the IP66 rating. Appliance
A captive clear cover is provided for
Inlets are to be mounted vertically into a
sealing out water and dust to maintain
standard 2 gang or larger enclosure.
the IP66 rating when not in use.
94mm
Cat No
56AI310 56AI320 56AI332
56AI416
56AI420 56AI432
56AI435
56AI440
Volts
250
250
250
500
500
500
500
500
Amps
10
20
32
16
20
32
35
40
Rated Operational
Voltage Ue (~50Hz)
Max. Thermal Current
28mm
Enclosed
Number of Pins
(Including Earth
25mm
3
3
3
4
4
4
4
4
Pin Configuration refer Pg 28
)
A
E
F
G
H
I
U
J
Terminal Capacity mm2 Min
1
1
2.5
1
1
2.5
2.5
2.5
Max
6
6
16
6
6
16
16
16
IP66 *
IP66
IP66
IP66
IP66
IP66
IP66
IP66
56AI450 56AI516 56AI520
56AI532
56AI535 56AI540
56AI550
Volts
500
500
500
500
500
500
500
Amps
50
16
20
32
35
40
50
4
5
5
5
5
5
5
Pin Configuration refer Pg 28
K
L
M
N
V
O
P
Terminal Capacity mm2 Min
4
1
1
2.5
2.5
2.5
4
16
6
6
16
16
16
16
IP66
IP66
IP66
IP66
IP66
IP66
IP66
56 AI310
IP rating
* when used with 56CS310 only
Cat No
95mm
20A
500V
THREE PHASE
50Hz
IP 66
CAT No.
Rated Operational
56 AI 420
Voltage Ue (~50Hz)
Max. Thermal Current
Enclosed
192mm
Number of Pins
(Including Earth
78mm
Max
28mm
IP rating
70mm
)
56 AI420
Page 29
Plugs
56P310
56PA320
56PAV332
250V Plugs
The 56 Series Single Phase plugs are
13A square pin configuration. All seven
available in 10A, 15A, 20A and 32A pin
plugs are IP66 rated when in use with 56
configurations to suit the Australian and
Series IP66 sockets, combination switched
New Zealand markets and in the British
sockets and RCDs.
Dimensional
Drawings
65mm 42mm
9.5mm 30mm
20mm
19mm
81.5mm
Cat No (Straight)
56P310
56P315
56P313
Cat No (Angled)
56P320
56P332
56PA320
56PA332
56 P310
Rated Operational
Voltage Ue (~50Hz)
Volts
250
250
250
250
250
Amps
10
15
13
20
32
3
3
3
3
3
Pin Configuration refer Pg 28
A
B
C
E
F
Cable Entry Diameter
Min
6
8
6
7
10
Max
9
11
10
16
27
0.75
1.0
0.75
1
2.5
1.5
1.5
1.5
6
16
Max. Thermal Current
Enclosed
78mm 55mm
Number of Pins
(Including Earth
20mm 20mm
85mm
)
Terminal Capacity mm2 Min
Max
56 P313
Plugs are available in chemically
resistant orange and can be ordered by
adding ‘V’ to the catalogue number.
Eg: 56PAV320. These plugs are fully
orange without clear bodies.
Page 30
Plugs
56P432
56PA432RF
500V Plugs
Dimensional
Drawings
78mm
52mm
20 AMP
500V
CAT No
56PAV716
IP66
56 P 420
These plugs are all rated IP66 when
inspection of the terminals and cable
fitted to a 56 Series cord connector or
entry. Plugs are available with 4 to 7
Socket Outlet. The body section is
pins, 16A to 50A to cover most
transparent for quick and easy
applications.
115mm
28mm
150mm
48mm
Cat No (Straight)
56P416
Cat No (Angled)
56PA416 56PA416K
40°
56P416K** 56P420
56P432
56P432RF*
56P435
56P440
56P450
56P516
56PA420 56PA432 56PA432RF* 56PA435 56PA440 56PA450 56PA516
Rated Operational
Voltage Ue (~50Hz)
Volts 500
500
500
500
500
500
500
500
500
16
20
32
32
35
40
50
16
4
4
4
4
4
4
4
4
5
G
Q
H
I
I
U
J
K
L
Rated Thermal Current
56 PA420
Enclosed
Amps 16
Number of Pins
(Including Earth
)
Pin Configuration refer Pg 28
78mm 59mm
Cable Entry Diameter
164mm
56 P432
Min 7
7
7
10
10
10
10
10
7
Max 16
16
16
27
27
27
27
27
16
Terminal Capacity mm2 Min 1
1
1
2.5
2.5
2.5
2.5
4
1
Max 6
6
6
16
16
16
16
16
6
keyway for high cycle applications
**RFSpecial
* Reefer Version with narrow locking ring for refrigerated container applications
78mm 59mm
123m
20mm
40°
164mm
58mm
56 PA432
58mm
78mm 59mm
164mm
56 PA440
Page 31
Plugs
Cat No (Straight)
56P520
56P532
56P535
56P540
56P550
56P616
56P716
56P720
Cat No (Angled)
56PA520
56PA532
56PA535
56PA540
56PA550
56PA616
56PA716
56PA720
Volts
500
500
500
500
500
500
500
500
Amps
20
32
35
40
50
16
16
20
5
5
5
5
5
6
7
7
Pin Configuration refer Pg 28
M
N
V
O
P
R
S
T
Cable Entry Diameter
Min
7
10
10
10
10
7
7
7
Max
Rated Operational
Voltage Ue (~50Hz)
Dimensional
Drawings
Rated Thermal Current
78mm 52mm
20 AMP
500V
CAT No
48mm 62mm
IP66
56 P 720
Enclosed
Number of Pins
(Including Earth
)
16
27
27
27
27
16
16
16
Terminal Capacity mm2 Min
1
2.5
2.5
2.5
4
1
1
1
Max
6
16
16
16
16
6
6
6
10A
10A
10A
Auxiliary Pins C1–C2
Maximum Current
Page 32
152mm
56 P720
Cord Connectors
56CR320
56CR432
Cord Connectors
Dimensional
Drawings
85mm 66mm
9.5mm
30mm
transparent for quick and easy
any 56 Series Plug or Appliance Inlet
identification of the socket configuration
maintaining the IP66 protection. The
and the cable termination.
body section and flap are both
86mm
Cat No
56CSC310 56CR310
56CR320 56CR332
56CR416
56CR420
56CR432 56CR435
Volts
240
240
240
240
500
500
500
500
Amps
10
10
20
32
16
20
32
35
3
3
3
3
4
4
4
4
Socket Configuration refer Pg 18
A
A
F
G
H
J
K
L
Cable Entry Diameter
Min
7
6
7
10
7
7
10
10
Max
11
9
16
27
16
16
27
27
1
0.75
1
2.5
1
1
2.5
2.5
Rated Operational
34.5mm 47mm
Voltage Ue (~50Hz)
6
3mm
PDL’s Cord Connectors can be used with
56 CR416
Maximum Current
Enclosed
Number of Socket Pins
(Including Earth
96mm
45mm 66mm
)
Terminal Capacity mm2 Min
130mm
142mm
Max
16A
500V
50HZ
IP Rating
IP66
56 CR 416
1.5
1.5
6
16
6
6
16
16
IP66*
IP66
IP66
IP66
IP66
IP66
IP66
IP66
* when used with 56AI310
Cat No
77mm
56 CR416
56CR440
56CR450 56CR516 56CR520
56CR532 56CR535 56CR540 56CR550
Volts
500
500
500
500
500
500
500
500
Amps
40
50
16
20
32
35
40
50
4
4
5
5
5
5
5
5
Rated Operational
Voltage Ue (~50Hz)
Maximum Current
Enclosed
58mm 66mm
96mm
Number of Socket Pins
(Including Earth
130mm
142mm
16A
500V
50HZ
)
Socket Configuration refer Pg 18
M
N
O
P
Q
R
S
T
Cable Entry Diameter
Min
10
10
7
7
10
10
10
10
Max
27
27
16
16
27
27
27
27
Terminal Capacity mm2 Min
2.5
4
1
1
2.5
2.5
2.5
4
IP66
56 CR 432
Max
77mm
56 CR416
IP Rating
16
16
6
6
16
16
16
16
IP66
IP66
IP66
IP66
IP66
IP66
IP66
IP66
Page 33
Pendant Outlet Kits
Suspension hooks that can be fitted to
56 Series Connectors enabling a chain
or cord to be attached for ceiling
mounting.
Cat No
56POK
56POK1
Suits
Suits
16A and 20A
32A to 50A
Connectors
Connectors
56POK and 56POK1
DIN Rail Covers
Din Rail Mounting Covers for MCBs, RCDs
or any full Din mounting accessory. 240V
neon indicator is standard unless otherwise
stated. Supplied with full Din rail and
mounting bracket for fitting to a standard
56E2 or larger enclosure.
56CB20 fitted with an RCD
Cat No
Module Width
Din Rail
Mounting Height
Neon Voltage (~50Hz)
Min
Max
Volts
56CB10
56CB20
56CB25
56CB30
56CB40
Single Pole
Double Pole
2 1/2 Pole
Triple Pole
Four Pole
18mm
36mm
44.5mm
54mm
72mm
58mm
58mm
58mm
58mm
58mm
62mm
62mm
62mm
62mm
67mm
240
240
240
240
240
Dimensional
Drawings
Module Mounting Lids
40mm
Ø22mm Diameter
Lids for mounting either one or two 22mm
diameter control modules. Lids can be
supplied in grey or clear for matching to any
control accessories.
500 Series IP66 Covers
95mm
Cat No
56L1/22/1
56L1/22/2
Mounting Hole Size
Ø22.5mm with 3.5mm Keyway
Mounting Holes
1
Mounting Centres
40mm
Colours Available
Grey, Orange or Clear
Cat No
56MO500/1
56MO500/2
56 L1/22/1
56 L1/22/2
95mm
2
22.5mm
30mm
94mm
28mm
IP 66
CAT No.
Covers to suit any PDL 500 or 600 Series
module providing IP66 protection. Ideally
suited for 500 and 600 Series switches, push
buttons, dimmers and neon indicators.
Mounting Hole Size
For PDL 500 and 600 Series Module Only
Mounting Holes
1
Mounting Centres
2
30mm
Page 34
56 MO 500/2
94mm
56 MO500/1
56 MO500/2
Lids
56L2/O fitted to 56E2
Dimensional
Drawings
95mm
28mm
56 L1
56DL4/CL fitted to 56E4
56 Series Lids are available in one gang
be used in conjunction with enclosures or
to six gang module sizes in both grey
other product in the series to produce a
and clear impact resistant polycarbonate
wide range of power distribution centres or
or chemically resistant orange. Lids can
utility boxes.
95mm
28mm
95mm
Cat No (Grey)
Cat No (Orange)
56L1/G
56l1/O
56L2/G
56L2/O
56L3/G
56L3/O
56XDL1/G
Cat No (Clear)
56L1/CL
56L2/CL
56L3/CL
56XDL1/CL 56DL2/CL 56DL4/CL
56DL4/G
56DL4/O
56DL6/G
56DL6/O
56DL6/CL
Module Size
1
2
3
1
2
4
6
Module Configuration
1x1
2x1
3x1
1x1
2x1
2x2
3x2
Grey
Grey
Grey
Grey
Orange
Orange
Orange
Clear
Clear
Clear
Clear
Colours Available
192mm
56DL2/G
56DL2/O
Grey
Grey
Grey
Orange
Orange
Orange
Clear
Clear
Clear
Length
95
191
289
95
191
191
289
Width
95
95
95
95
95
191
191
Depth
28
28
30
100
63
63
63
56 L2/G
Dimensions
96mm
30mm
289mm
56 L3
63mm
95mm
190mm
191mm
77mm
28mm
100mm
95mm
192mm
95mm
56 XDL1
287mm
191mm
78mm
56 L4
56 DL2/G
Page 35
56 L6
Enclosures
56E1/25/25
56E8 including dividers
PDL 56 Series enclosures are in two
moulded in impact resistant grey PVC. All
types: shallow, in single and two gang
multigang enclosures are supplied complete
sizes, suitable for mounting blank lids,
with a selection of bridges to provide a
single phase switches, single phase
sealing base between individual modules and
sockets, sunset switches and time
dividers for separating incompatible circuits.
delays; and standard 63mm deep
Enclosures are supplied with a range of
enclosures, which range in size from
conduit entries according to the chart.
Dimensional
Drawings
62mm
101mm
23mm
101mm
single gang to nine gang. They are
20mm
56 E1
Cat No
56E1S
56E1
56E1/25/25
56E2S
56E2
56E2
56E2/25/25
56E2/40
102mm
40mm
Food Industry
Module Size
1 Shallow 1
1
2 Shallow 2
2
2
2
1x1
1x1 2x1
2x1
2x1
2x1
2x1
2x1
102mm
Module Configuration 1 x 1
Dimensions
Length
101
102
102
197
198
198
198
198
198
Width
101
102
102
101
102
102
102
102
102
Depth
38
63
63
38
63
63
63
63
63
20mm
56 E1S
20mm
102mm
62mm
Conduit Entries
Metric mm*
25
2
1
2
2
1
2
2
—–
32
–––
1
1
—–
1
—–
1
—–
40
–––
—
—
—–
–––
—–
—–
2
1
1
2
1
1
2
2
—–
—–
1
—–
—–
1
—–
1
—–
1x25-20
1x32-25 1x32-25
2x25-20
1x20-20 1x32
1x25-20
1x25-20
1x25
1x32-25
1x32-25
Conduit Reducers
Supplied
198mm
25/20
32/25
Rear Entry Cut-Outs
56 E2
23mm
* Special enclosure threaded entries are available on request.
40mm
101mm
101mm
40mm
102mm
63mm
20mm
62mm
38mm
23mm
199mm
197mm
102mm
20mm
56 E2/25/25
23mm
56 E2S
20mm
Page 36
56 E2/25/2
Enclosures
Dimensional
Drawings
Cat No
Module Size
56E3
56E4VH 56E4
56E6
56E8
56E9
3
4
4
6
8
9
2
4x1
2x2
3x2
4x2
3x3
2x1
Module Configuration 3 x 1
20mm
102mm
56ED2/40
Dimensions
63mm
Length
296
396
198
296
396
296
198
Width
102
102
198
198
198
296
101
Depth
63
63
63
63
63
63
100
25
1
2
2
2
2
3
---
32
1
1
4
4
2
3
---
40
---
---
---
---
---
---
2
Conduit Entries
Metric mm*
295mm
Conduit Reducers
Supplied
25/20
1
---
1
1
---
1
---
32/25
1
---
1
1
---
1
---
3x32-25
2x25
2x32-25
2x25
4x25
4x25
1x25
1x32
2x40-32 2x32
2x32
2x32
2x25
1x32
1x40
2x40
2x40
2x40
23mm
56 E3
Rear Entry Cut-Outs
23mm
64mm
96.5mm
198mm
* Special enclosure threaded entries are available on request.
198mm 96.5mm
20mm
56 E4
20mm
102mm
23mm
63mm
63mm
23mm
96.5mm
198mm
295mm
64mm
295mm
391mm
391mm
20mm
20mm
56 E8
23mm
56 E4VH
23mm
64mm
56 E9
96.5mm
198mm
295mm
20mm
56 E6
Page 37
96.5mm
96.5mm
Pendant Enclosures
Cat No
56PE2/25
56PE2/32
Conduit Entries
1 x 25mm
1 x 32mm
Conduit Reducers Supplied
1 x 25/20mm
---
Module Size
1x2
1x2
PDL’s Pendant enclosure allows you to
mount two 56 Series single gang products
in a fully enclosed, portable unit so you can
hang up your power supply.
A divider separates the two mounted
products and produces a seal to ensure the
IP66 rating.
In the interests of user convenience, the
enclosure features finger recesses for
holding while unplugging the plug from
the socket.
They have a strong, large loop for attaching
a chain, as well as angled cable entry for
ease of wiring.
Dimensional
Drawings
25mm or 32mm
threaded entry
102mm
30°
90mm
102mm
18mm
18mm
Available in high-impact grey and chemically
resistant orange and white.
180mm
56 PE2
Flush Surrounds
PDL 56FA Series
Mounting Details
0
OFF
56FA1
56FA2
Supplied with metal wall mounting plate
and foam sealing gasket. Ideal for flush
mounting of single or two gang
Cat No
56FA1
56FA2
Module Size
1
2
Colour
Grey
Grey
Dimensions
accessories maintaining the IP66
Length
157
254
protection. Moulded in grey impact
Width
157
157
resistant UV stabilised PVC.
Dimensional Drawings
157mm
84mm
180.5mm
84mm
157mm 84mm
84mm
11.5mm
11.5mm
84mm
157mm
84mm
253.5mm
56 FA1
56 FA2
Page 38
84mm
20A
500V
THREE PHASE
50Hz
IP66
CAT No 56
SW
320
1
ON
PDL’s 56 Series D.O.L Motorstarters
The Watertight Motor Starter
Solution with features designed to
out perform all others…
56 Series
Compatible
IP66
Protection
NZ Made for
NZ Conditions
Combination Isolating
Switch/D.O.L. Motorstarter
1
Pre-wired
9
2
Unique cover mounted contactor and
overload (allows for first fitting of
enclosure and conduit if required)
10 Available with or without enclosure
Shrouded push buttons
11 High impact resistant UV stabilised
polycarbonate cover
3
Both 230V and 400V versions available
4
AC23 11kW motor rated switch
5
Maximum contactor rating 5.5kW
(7.5hp)
6
1 x 25mm conduit entry
7
2 x 20mm conduit entries
8
Finger proofing on all terminals
12 Raised stop button
13 Enclosure manufactured from UV
stabilised rigid PVC
14 Easy adjustment of overload setting, no
tools required
15 Terminal screws combination slot-pozi
head
7
3
5
10
4
13
For tough motor
control situations!
A range of rugged, dependable
D.O.L. Motor Starters, for
single phase motors up to
2.2kW (3.0hp) and three
phase motors up to 5.5.kW
(7.5hp). For maximum
versatility and flexibility there
are four versions in each of
the single and three phase
options:
1
8
11
2
14
15
9
12
1 START/STOP RESET
2 STOP/RESET only
3 START/STOP RESET with
isolating switch
4 STOP/RESET with
isolating switch
Page 39
6
Products in the Motor Starter range
Dimensional
Drawings
102
96
40
ø20mm conduit
entry (x2)
ON
192
198
OFF
START
STOP
RESET
56MS230R
3
56MS230
ø25mm
conduit entry (x1)
123
105
63
17.5
20
56MS400SW
116
56MS400SWR
102
96
ø25mm conduit
entry (x1)
Product Descriptions
56MS230E
Coil voltage 230V~50Hz
Start and Stop/Reset Controls
With enclosure
56MS400
Coil voltage 400V~50Hz
Start and Stop/Reset Controls
Less enclosure
56MS400E
Coil voltage 400V~50Hz
Start and Stop/Reset Controls
With enclosure
56MS230SWR
Coil voltage 230V~50Hz
Stop/Reset Control only
With isolating switch
Less enclosure
56MS400SWR
Coil voltage 400V~50Hz
Stop/Reset Control only
With isolating switch
Less enclosure
START
192
56MS400R
Coil voltage 400V~50Hz
Stop/Reset Control only
Less enclosure
56MS230SW
Coil voltage 230V~50Hz
Start and Stop/Reset Controls
With isolating switch
Less enclosure
56MS230SWE
Coil voltage 230V~50Hz
Start and Stop/Reset Controls
With isolating switch
With enclosure
56MS400SW
Coil voltage 400V~50Hz
Start and Stop/Reset Controls
With isolating switch
Less enclosure
56MS400SWE
Coil voltage 400V~50Hz
Start and Stop/Reset Controls
With isolating switch
With enclosure
198
56MS230
Coil voltage 230V~50Hz
Start and Stop/Reset Controls
Less enclosure
STOP
RESET
3
56MS230R
Coil voltage 230V~50Hz
Stop/Reset Control only
Less enclosure
ø20mm
conduit entry (x2)
40
105
63
20
17.5
116
Page 40
Connection Diagrams
Starter and Overload
MAINS SUPPLY
L1
L2
L3
GENERAL
Direct on line Motor Starter
Maximum Rated Output
AC3 5.5kW 400V – Three Phase
AC3 2.2kW 230V – Single Phase
Maximum Thermal Current Enclosed lthe 16A
IP66 Dust and Watertight AS 1939:1990
BS 5490:1985
IEC 529 :1989
Finger proof terminals on contactor, overload
and isolating switch to IP20
3
6
6
C
14
96
2
C
14
98
STOP
RESET
95
START
400
4
4
98
4
6
U
V
W
MOTOR LOAD
96
STOP
RESET
95
2
4
6
N
U
V
W
MOTOR LOAD
Type:
MAINS SUPPLY
L1
L2
L3
1
3
5
Remove link between
A1 and 1 at terminal 1
on contactor and
connect to neutral.
E
13
2
1
A1
START
230
MAINS SUPPLY
Remove link between A1
L1
L2
L3 and 1 at terminal 1 on
A2
2
4
6
contactor and connect
to neutral.
3
96
STOP
RESET
95
4
6
Remove link wire attached
to contactor terminal 3.
U
V
W
MOTOR LOAD
13
5
2
1
A1
START
230
A2
98
2
1
C
14
ON
OFF
E
N
2
4
6
C
14
98
MAINS SUPPLY
N
96
STOP
RESET
95
2
4
6
U
V
W
MOTOR LOAD
ENCLOSURE
Rigid PVC – UV Stabilised, impact resistant.
Screwed Conduit Entries Back Entry Cut-Outs
1 x Ø 25mm
1 x Ø 32mm
2 x Ø 20mm
1 x Ø 25mm
1
E
A
3
5
13
2
1
A1
START
230
Connect link wire
attached to contactor
terminal 3 to switch.
A2
2
4
6
C
14
98
96
STOP
RESET
95
2
MAINS SUPPLY
N
A
1
3
6
Connect link wire
attached to contactor
terminal 3 to terminal
6 on overload.
ON
OFF
REMOTE STOP/START PUSH BUTTONS
13
5
14
13
2
1
A1
START
230
A2
4
A
N
MOTOR LOAD
E
MOTOR RATED ISOLATING SWITCH
Used with 56MS230SW, 56MS400SW,
56MS230SWR, 56MS400SWR
3 pole Isolating. Motor rated to
AC23
11kW
415V
BS5419
M110
20A
500V
AS3133
START PUSH BUTTON SWITCH
Rated Insulation Voltage Ui: 500V
AC
Rated Thermal Current Ith: 16A
Utilization Category:
AC11
4A
250V
AC11
2A
415V
OVERLOAD
Full load current rating:
0.40 - 16AMPS
in 10 size ranges
Rated Insulation Voltage:
Ui: 660V AC
Single Phase Protected
Temperature Compensated: From 0 - 35°C
Manual or Auto Reset:
Manual Test Incorporated:
Auxillary Contacts
Rated Insulating Voltage:
500V AC
Rated Operational Current le: AC11 2A 500V
Terminal Capacities
Main:
Stranded 0.5 - 2.5mm2
Solid 0.5 - 4mm2
Auxillary:
Stranded 0.5 -2.5mm2
Solid 0.5 - 2.5mm2
START
2
2
1
2
2
1
400
13
5
A1
A2
13
A1
A2
CONTACTOR
S11 10 Electromagnetic Contactor
3 pole + N/O Auxillary
Frequency:
50Hz AC
Utilization Category:
AC3 7.5kW 400V Three Phase
AC3 2.2kW 230V Single Phase
Rated Insulation Voltage Ui:
690V~
Rated Thermal Current Enclosed Ithe: 16A
Coil Characteristics:
Pull in 0.85 - 1.1 Uc
(Control Circuit Voltage)
Drop Out 0.4 - 0.6 Uc
Terminal Capacities: Stranded 0.5 -2.5mm2
Solid 0.75 - 4mm2
ON
OFF
E
1
E
MAINS SUPPLY
L1
L2
L3
1
3
5
2
4
6
START
98
96
STOP
RESET
95
2
4
A
N
MOTOR LOAD
6
Connect link wire attached
to contactor terminal 3 to
terminal 6 on overload.
Page 41
96
C
14
Remove link
between 14
and 96 on
starter and
connect as
shown.
STOP
REMOTE STOP PUSH BUTTON
96
14
STOP
Overload Selection
INTERNATIONAL
STANDARDS AND
APPROVALS
Direct On Line
Motorstarter
Overloads
Replacement Coils
Cat No
International Protection IP66 to AS
1939:1990 and BS 5490:1977.
AS 1202 Pt 1:1981 AC Motorstarters Direct
on Line
BS 4941 Pt 1:1979 Direct on Line AC
Starters
IEC 947, switch operation and cover marking
Patented Stop/Reset Mechanism
The switched versions (56MS400SW and
56MS230SW) comply with New Zealand
Electrical Wiring Regulation 108.
Manufactured to ISO 9001
Made in New Zealand
Description
Cat No
Description
56MSC230
230V~50Hz Coil
56T9062
0.4-0.62A
56MSC400
400V~50Hz Coil
56T9092
0.6-0.92A
56MSC24
24V~50Hz Coil
56T913
0.85-1.3A
56T919
1.2-1.9A
56T928
1.8-2.8A
56T942
2.7-4.2A
56T962
4.0-6.2A
56T992
6.0-9.2A
56T9120
8.0-12.0A
56T9160
11.0-16.0A
Contactor
IEC 947
EN 60947
VDE 0660
Manufactured to ISO 9001
Made in New Zealand
Direct on Line Starter, Full Load Current
MOTOR RATING
kW
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
THREE PHASE 400V
Overload
SINGLE PHASE 230V
hp
ADJUSTMENT
RANGE (A)
RECOMMENDED
OVERLOAD
ADJUSTMENT
RANGE (A)
0.25
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.5
7.5
0.6-0.92
0.6-0.92
0.85-1.3
1.2-1.9
1.8-2.8
2.7-4.2
2.7-4.2
4-6.2
6-9.2
6-9.2
8-12
56T9092
56T9092
56T913
56T919
56T928
56T942
56T942
56T962
56T992
56T992
56T9120
1.8-2.8
2.7-4.2
4-6.2
4-6.2
6-9.2
8-12
11-16
RECOMMENDED
OVERLOAD
DEFINITION
OF UTILIZATION
CATEGORIES
56T928
56T942
56T962
56T962
56T992
56T9120
56T9160
to IEC 947-1 BS 5419
AC23A:
NOTE: “Full Load Currents” given in this table are intended as a guide only. For exact full load current,
consult the motor manufacturers specifications or the motor nameplate.
THERMAL OVERLOAD
CHARACTERISTICS
Tripping Characteristics
w…from hot condition k…from cold condition
10000
k
100
10
w
tripping time/s
Short Circuit Capability
Setting Range (A) Max. Fuse Ratings (A)
quick+)
slow+)
1000
Average values at 20°c
ambient temperature, tripping
three-phase from cold
condition
1
0.1
0.01
0.001
0.8
1
2
4
6
10
nominal current
20
IEC 292
VDE 0660
BS 587 and BS 5424
Manufactured to ISO 9001
Made in Denmark
40
60
100
0.40 – 0.62
0.60 – 0.92
0.85 – 1.3
1.2 – 1.9
1.8 – 2.8
2.7 – 4.2
4 – 6.2
6 – 9.2
8 – 12
11 – 16
a
c
a
c
35
35
35
35
35
35
—
—
—
—
4
6
6
10
16
25
35
35
35
35
25
25
25
25
25
25
25
—
—
—
4
4
4
6
10
20
20
25
25
25
According to IEC 292-1A
coordination types “a” and “c”.
Page 42
Switching of motor loads or
other highly inductive loads.
Occasional:
Making 10 times le
(Rated operational current)
Breaking 8 times le
AC3:
Starting of squirrel cage motors, and
switching off motors during running.
Occasional:
Making 10 times le
Breaking 10 times le
AC11:
Feed control of magnetic
drives, contactors, valves and
electromagnets.
Occasional:
Making 11 times le
Breaking 11 times le
Accessories
56MF
NO9 BLUE; NO9 YELLOW; NO9 RED
Mounting Feet and Indenticaps
Cat No
RED/YELLOW/BLUE to fit all covers
56MF
Material
316 Stainless Steel
available in single colour packs of 20 or
Stand off height
9.0mm
a mixed pack of 60.
Mounting Centres
82mm
Package Contents
Mounting Feet
2
Mounting Screws
4
Socket Covers
Cat No
56SOCVR
Description Socket Cover General
56SOCVR10
Two covers cater for all 56 Series
Socket Cover 10A, 15A
standard socket products to allow safe
replacement of damaged covers.
Plug Body
Description
The 56 Series has a comprehensive
56P16/20A
16/20A Straight
range of plug bodies and plug sleeve
56PA16/20A
16/20A Angled
kits. These allow for the replacement of
56P32/35A
32/35A Straight
damaged plug bodies or sleeves through
56PA32/35A
32/35A Angled
56P40/50A
40/50A Straight
56PA40/50A
40/40A Angled
Cat No
extensive use or misuse.
They are available in all plug sizes from
16A up and in both standard impact
Plug Sleeve Kits
Cat No
Description
resistant polycarbonate or chemical
resistant orange.
56P16
16A
Plug bodies also fit 56 Series cord
56P20/250
20A 3 pin
connectors
56P32/250
32A 3 pin
56P20/500
20A 4+ pin
56P32/500
32A 4+ pin
56P40
40A
56P50
50A
Page 43
PDL products are privileged to reside in almost every New Zealand home and
office. People touch PDL products millions of times across the country, every day.
PDL is also a significant exporter, earning foreign exchange for New Zealand by shipping industrybest value-added product around the globe.
The PDL Electrical Products range (largely made in Christchurch) offers an extensive range of
switch and wiring accessories. The PDL Electronics range (made in Napier) involves high-tech
electronic solutions for industrial applications.
In just over six decades, PDL has stamped its indelible hallmark of quality and innovation on the
domestic, commercial and industrial markets in everything from electrical accessories to industrial
switchgear, AC variable speed drives to home automation.
Plastic & Die Casting Ltd, founded in 1947 was purchased by the then Bob
Stewart in 1957 and renamed PDL Industries Ltd. It was Sir Robertson Stewart's
acumen which created the vehicle which allowed PDL to grow and thrive for
the balance of the 20th century. PDL grew from 12 staff and sales of NZ$5000
per annum, to 2000 staff and NZ$350m sales across 3 continents – in 60 years.
Schneider Electric acquired the PDL Group in 2001. Schneider Electric's world-wide distribution
network now offers the PDL brand to a wider global market.
PDL products continue to be designed and engineered by New Zealanders, from independent
PDL manufacturing facilities in Christchurch and Napier. PDL is a Kiwi brand and we take genuine
pride in that.
PDL is part of Schneider Electric's family of leading electrical brands. As with Merlin Gerin,
Modicon, Square D and Telemecanique – PDL products are marketed locally by Schneider Electric
New Zealand.
PDL Electrical Products are available through electrical wholesalers
New Zealand wide.
PDL Electrical Products are designed and engineered to ISO 9001.
Resellers source PDL in New Zealand through Schneider Electric.
Freecall 0800-652 999, freefax 0800-101 152
Email orders to enquiry@pdl.co.nz
Online product detail - download from www.pdl.co.nz
NZ0602PDL56, p r i n t e d J u n e 2 0 0 2 , r e p l a c e s F e b r u a r y 2 0 0 0 e d i t i o n
PDL is a brand of Schneider Electric
Download