W I R I N G D E V I C E - K E L L E M S CATALOG 2011 INDUSTRIAL • COMMERCIAL • DATACOM A/V www.hubbell-wiring.com • RESIDENTIAL Switches Switched Enclosures Circuit-Lock® Unfused Disconnect Switches “Suitable as Motor Disconnect” Features and Benefits Circuit-Lock® 30, 60, and 100 Ampere Unfused Disconnect Switches NEC section 430.102(B) requires each motor controller to have a disconnect within line of sight from the motor and driven equipment. NEC section 430.109(A)(6) recognizes that a manual motor controller and disconnect can be the same unit, provided it has been tested for this purpose. Hubbell’s Circuit-Lock® Unfused Disconnect Switches are UL listed as a manual motor controller and also “suitable as a motor disconnect” and meet these code requirements. In addition, the enclosure offers the ability to lock directly wired motor loads in the OFF position to comply with OSHA Lockout/Tagout regulations. This safety enclosure is Type 4X (Wash down, Corrosion resistant) and is also suitable for use with metallic conduit. The switch is mounted on an internal frame that is integral with the enclosure and bonds all grounds, and it accepts auxiliary contacts that can be used to signal PLC controllers. Circuit-Lock® Unfused Disconnect Switches Features and Benefits Stainless steel hardware for corrosion resistance Molded-in conduit opening and field installed hub Internal frame automatically bonds all grounds Reversible interior accommodates top or bottom conduit opening High visibility red handle can be locked in the OFF position as a method of compliance with OSHA Lockout/ Tagout requirements Captured neoprene gasket provides a watertight seal between cover and base Type 4X enclosure is molded of rugged Valox® to resist abuse, corrosion and enhance safety HBLDS3 Circuit-Lock® Unfused Disconnect Switches are available in 30, 60 and 100 Amp, 600V AC ratings. Auxiliary contacts are available for control circuit applications including the ON/OFF control of pilot lights or signal for programmable controllers. Three molded-in conduit drill points are located on the top, bottom, and back surface of enclosure Conduit hub and adjustable mounting feet are supplied for ease of installation. Valox® is a trademark of SABIC Innovative Plastics, acquired from General Electric Company. C-32 www.hubbell-wiring.com Dimensions in Inches (mm) Circuit-Lock® Unfused Disconnect Switches UL Listed, CSA CertiÞed TYPE 4, 4X and 12 Enclosure Rating “Suitable as Motor Disconnect” IP66 SUITABILITY 30, 60 and 100 Amp Unfused Disconnect Switches Description Catalog Number 30A Circuit-Lock disconnect switch. 30A Circuit-Lock disconnect switch for use with variable frequency drives. 30A Circuit-Lock disconnect switch with HBLAC1 aux. contact. 30A Circuit-Lock disconnect switch with HBLAC2 aux. contact. 30A Circuit-Lock disconnect switch without conduit knockout or conduit fitting. 30A Circuit-Lock disconnect switch with HBLAC1 aux. contact without conduit knockout or conduit fitting. 30A Circuit-Lock disconnect switch with 3 aux. contacts, w/o conduit knockouts. Break before main break – 1 set “normally open”, 1 set “normally closed”. Break after main break – 2 sets “normally open”, 1 set “normally closed”. 60A Circuit-Lock disconnect switch. 60A Circuit-Lock disconnect switch with HBLAC1 aux. contact. 100A Circuit-Lock disconnect switch. 100A Circuit-Lock disconnect switch with HBLAC1 aux. contact. HBLDS3 HBLDS3VFD HBLDS3AC HBLDS3AC2 HBLDS3NK HBLDS3ACNK Switched Enclosures Switched Enclosures HBLDS33ACNK HBLDS3AC HBLDS6 HBLDS6AC HBLDS10 HBLDS10AC Auxiliary Contacts for 30, 60 and 100 Amp Switch, A600 Pilot Duty Description Catalog Number “Break After Main Break”, 1 set of n/o contacts, 1 set of n/c contacts. “Break Before Main Break”, 1 set of n/o contacts. HBLAC1* HBLAC2* HBLAC1 Ground Block Description Catalog Number For 30A switches. For 60A and 100A switches. HBL30RGB HBL60100RGB HBLAC2 Description Catalog Number For 30A switches. For 60A switches. For 100A switches. HBL30RNB HBL60RNB HBL100RNB Note: * Not for use with HBLDS33ACNK. 30A Units are supplied with one ¾ in. N.P.T. Raintight conduit fitting. 60A and 100A Units are supplied with two 1¼ in. N.P.T. Raintight conduit fittings. See page C-34 for wiring details. Dimensions in Inches (mm) www.hubbell-wiring.com HBL30RGB HBL30RNB C-33 Circuit-Lock® Unfused Disconnect Switches Neutral Block Switched Enclosures Switched Enclosures Circuit-Lock® Unfused Disconnect Switches “Suitable as Motor Disconnect” IP66 SUITABILITY Replacement Covers Description Catalog Number For 30A switches. For 60A switches. For 100A switches. HBLDS3RC HBLDS6RC HBLDS10RC Replacement Switches HBLDS3RC Description Catalog Number For 30A switches. For 60A and 100A switches. For HBLDS33ACNK. HBLDS3RS HBLDS60100RS HBLDS33ACRS Replacement Mounting Feet HBLDS3RS Description Catalog Number For 30A switches. For 60A and 100A switches. HBLRFT1 HBLRFT2 Note: 30A Units are supplied with one ¾ in. N.P.T. raintight conduit fitting. 60A and 100A Units are supplied with two 1¼ in. N.P.T. raintight conduit fittings. kage of 10 feet and 10 screws. HBLRFT1 Circuit-Lock® Unfused Disconnect Switches Variable Frequency Drive Diagram HBLDS3VFD Variable Frequency Drive Main Switch Enable Input C-34 Normally Open Early Break Auxiliary Contacts www.hubbell-wiring.com Drive Control Voltage 24V DC Dimensions in Inches (mm) Switched Enclosures Switched Enclosures Circuit-Lock® Unfused Disconnect Switches Dimensions and Specifications Dimensions Key 30A inch (mm) 60A/100A inch (mm) A B C D E F G 6.00 5.12 4.12 6.62 7.62 8.50 4.12 (152) (130) (105) (168) (194) (216) (105) 7.75 6.87 4.75 8.00 9.95 11.00 5.94 (197) (175) (121) (203) (253) (279) (151) Horsepower Ratings Voltage 1Ø 120V AC 30A 60A 100A 1 7.5 7.5 1Ø 200–240V AC 3 15 15 1Ø 480V AC 5 30 30 3Ø 200–240V AC 7.5 30 30 3Ø 480V AC 15 50 50 3Ø 600V AC 15 50 50 Circuit-Lock® Unfused Disconnect Switches Specifications Moisture Resistance Flammability Operating Temperature Materials Part Material Base Top Handle Conduit Hub Enclosure Gasket Shaft (Unfused) Shaft Seal Frame Enclosure Screws Valox® Valox® Valox® Zinc 30A Unfused - ¾ in.; 60/100A Unfused - 1¼ in. Neoprene Valox® Molded Neoprene Galvanized Steel Stainless Steel 300 Series Valox® is a trademark of SABIC Innovative Plastics, acquired from General Electric Company. Dimensions in Inches (mm) www.hubbell-wiring.com C-35 Dimensions and Specifications UV Resistance Dielectric Voltage Max. Working Voltage Current Interrupting Short Circuit Withstand Rating (Motor Disconnect) Terminal Identification Product Identification Mounting Impact Resistance Outdoor – Type 4X (Wash down, Corrosion resistant), IP66 suitability; Indoor – 30A Type 12K (Dust-tight, Falling Dirt, Noncorrosive Liquids with Knockout). 60A and 100A Type 12 (Dust-tight, Falling Dirt, Noncorrosive Liquids). UL94-5VA and V0 Classification. Maximum Continuous 67°F (75°C); Minimum Continuous -40°F (-40°C) without impact. All materials are UV stabilized. Withstands 3000V AC minimum. 600V AC RMS. Certified for current interrupting at full rated current and voltage. Suitable for use on a circuit capable of delivering not more than 10,000 RMS symmetrical amperes, 600V AC max. In accordance with UL, CSA and international conventions. Identification and ratings are part of external label. External fully adjustable feet. In accordance with UL 746C. Switched Enclosures Switched Enclosures Circuit-Lock® Fused Disconnect Switches “Suitable as Motor Disconnect” Features and Benefits Circuit-Lock® 30 and 60 Ampere Fused Disconnect Switches The Circuit-Lock Fused Disconnect Switch provides fused switched control of a directly wired load. The switch cannot be turned ON unless the enclosure cover is closed. The fuses cannot be accessed until the switch is turned OFF. The fuse holder accepts Class “J” fuses. This enclosure is non-metallic and is listed for Outdoor/Indoor (Type 4X Wash down, Corrosion resistant). The handle can be locked in the OFF position to comply with OSHA Lockout/Tagout regulations. Three molded-in conduit drill points are located on the top, bottom, and back surface of enclosure. Conduit hub provided: 30A 1 inch N.P.T., 60A 1¼ inch N.P.T. Adjustable mounting feet (4) can be mounted in any of three positions for ease of installation Circuit-Lock® Fused Disconnect Switches Features and Benefits Stainless steel hardware for corrosion resistance Fused disconnect switches accept Class “J” fuses Safety interlocked fuse access door Non-metallic enclosure meets UL 50 Type 4X (watertight) 12K (dusttight) and IP66 suitability requirements. Enclosure is molded of rugged Valox® to resist abuse, corrosion and enhance safety. All external hardware is stainless steel Conduit hub and adjustable mounting feet are supplied with each Circuit-Lock® Fused Disconnect Switch. Lockable high visibility red handle to meet OSHA Lockout/Tagout Removable door for ease of wiring and installation Stainless steel ¼ inch turn door fasteners for quick, easy access to fuses. FDS30 Enclosure door can be locked to prevent unauthorized access. Additionally, if the switch is ON, the door cannot be opened. Valox® is a trademark of SABIC Innovative Plastics, acquired from General Electric Company. C-36 www.hubbell-wiring.com Compact Fused Disconnect Switch accepts Class “J” fuses. Fuse holders are top mounted for easy access. The switch accepts auxiliary contacts for control circuit applications including the ON/OFF control of remote pilot lights or signal for programmable controllers. Dimensions in Inches (mm) Circuit-Lock® Fused Disconnect Switches UL Listed, CSA CertiÞed TYPE 4, 4X and 12 Enclosure Rating “Suitable as Motor Disconnect” Dimensions IP66 SUITABILITY 30 and 60 Amp Fused Disconnect Switches Description Catalog Number 30A Circuit-Lock fused disconnect switch. 60A Circuit-Lock fused disconnect switch. FDS30* FDS60* Switched Enclosures Switched Enclosures Note: *Class “J” fuses not included. Auxiliary Contacts Description Catalog Number Auxiliary contact, normally open, A600 pilot duty. Auxiliary contact, normally closed, A600 pilot duty. ACFSNO ACFSNC FDS30 Watertight Closure Plug Kits Description Catalog Number For 30A Circuit-Lock fused disconnect switch. For 60A Circuit-Lock fused disconnect switch. MICPK30 MICPK60 Replacement Mounting Feet Catalog Number Replacement mounting feet and screws for 30A and 60A fused disconnect switches. HBLRFT2 ACFSNO Circuit-Lock® Fused Disconnect Switches and Dimensions Description Note: 30A Units supplied with two 1 in. N.P.T. raintight conduit fittings. 60A Units supplied with two 1¼ in. N.P.T. raintight conduit fittings. Package of 10 feet and 10 screws. MICPK30 HBLRFT2 Dimensions 7.27" (184.7) 9.31" (236.5) 3.60" (91.4) 10.18" (258.6) 7.19" (182.6) 11.46" (291.6) 12.37" (314.2) 15.03" (381.8) 14.48" (367.8) 15.36" (390.1) 8.43" (214.1) Dimensions in Inches (mm) www.hubbell-wiring.com C-37 Switched Enclosures Switched Enclosures Circuit-Lock® Fused Disconnect Switches Horsepower Ratings and Specifications Horsepower Ratings Catalog Number Ratings Volts FDS30 30A 600V AC Max. FDS60 60A 600V AC Max. 120V AC 208-240V AC 3Ø 240V AC 3Ø 480V AC 3Ø 600V AC 3Ø Y 120/208V AC 3Ø Y 277/480V AC 3Ø Y 347/600V AC 120V AC 208-240V AC 3Ø 240V AC 3Ø 480V AC 3Ø 600V AC 3Ø Y 120/208V AC 3Ø Y 277/480V AC 3Ø Y 347/600V AC Standard HP Maximum HP* 0.5 1.5 3 5 7.5 3 5 7.5 1.5 3 7.5 15 15 7.5 15 15 2 3 7.5 15 20 5 15 20 3 7.5 15 30 40 15 30 40 Note: * Requires time delay fuses. 30A Units supplied with two 1 in. N.P.T. raintight conduit fittings. 60A Units supplied with two 1¼ in. N.P.T. raintight conduit fittings. Fuse and Short Circuit Information Horsepower Ratings Short Circuit Withstand Rating The starting current of motors of more than the standard horsepower rating may require the use of fuses with appropriate time-delay characteristics. Suitable for use on a circuit capable of delivering not more than 100,000 RMS symmetrical amperes at the voltage rating of receptacle when protected by Class “J” fuses. Note: Replacement fused switch must be the same type Hubbell switch as original and have equal or greater short circuit current withstand rating. Circuit-Lock® Fused Disconnect Switch Specifications Moisture Resistance Horsepower Ratings and Specifications Flammability Operating Temperature UV Resistance Dielectric Voltage Max. Working Voltage Impact Resistance Terminal Identification Product Identification Mounting Fuse Types Outdoor – Type 4X (Wash down, Corrosion resistant), IP66 suitability; Indoor – Type 12 (Dust-tight, Falling Dirt, Noncorrosive Liquids). UL94-5VA and V0 Classification. Maximum Continuous 75°C; Minimum Continuous -40°C without impact. All materials are UV stabilized. Withstands 3000V AC minimum. 600V AC RMS. In accordance with UL 746C. In accordance with UL, CSA and international conventions. Identification and ratings are part of external label. External fully adjustable feet. UL Listed, Class “J”; CSA Certified, HRCI-J. Materials Part Material Base Door Handle Conduit Hub Enclosure Gasket Shaft Shaft Seal Frame Ground Plate Enclosure Screws Valox® Valox® Valox® Zinc, 30A Fused – 1 in., 60A Fused – 1¼ in. Neoprene Brass Neoprene Galvanized Steel Galvanized Steel Stainless Steel 300 Series Valox® is a trademark of SABIC Innovative Plastics, acquired from General Electric Company. C-38 www.hubbell-wiring.com Dimensions in Inches (mm) Pin and Sleeve Devices Pin and Sleeve Insulgrip® Mechanical Interlocks Features and Benefits Non-metallic enclosure meets UL 50 Type 4X (watertight) 12K (dust-tight) and IP66 suitability requirements. Enclosure is molded of rugged thermoplastic Valox® to resist abuse, corrosion and enhance safety. All external hardware is stainless steel Three “molded in” conduit drill points are located on the top, bottom, and back surface of enclosure. Conduit hub provided: 30A 1 inch N.P.T., 60A 1¼ inch N.P.T. Adjustable mounting feet (4) can be mounted in any 1 of 3 positions for ease of installation The patented Plug-Check™ mechanism detects the presence of the plug. It operates as a clutch to engage the handle with the switch and captures the plug. This action prevents the plug from being removed until the switch is turned OFF High visibility red handle can be locked in the OFF position as a method of compliance with OSHA lockout requirements. Accepts up to a 6QE inch padlock shackle Removable door for ease of wiring and installation Insulgrip® Mechanical Interlock Spring-loaded receptacle liftcover with gasket ensures dust tight rating; liftcover provides watertight seal when turned and locked Compact Fused Disconnect Switch accepts Class “J” fuses. Fuse holders are top mounted for easy access. The switch accepts auxiliary contacts for control circuit applications including the ON/OFF control of remote pilot lights or signal for programmable controllers. Conduit hub and mounting feet are supplied with each Insulgrip® Mechanical Interlock HBL430MIFS2W Thermoset polyester contact carrier provides resistance to electrical tracking and withstands higher temperatures. Thermoset properties provide excellent dimensional stability, low moisture absorption, and superior dielectric strength. Stainless steel ¼ turn door fasteners for quick, easy access to fuses. Enclosure door can be locked to prevent unauthorized access. Additionally, if the switch is ON, the door cannot be opened. Valox® is a trademark of SABIC Innovative Plastics, acquired from General Electric Company. E-38 www.hubbell-wiring.com Dimensions in Inches (mm) Insulgrip® Mechanical Interlocks - Style II, Fused and Unfused TYPE 4X** 30 and 60 Ampere, 600/250 Voltage AC/DC, 50-400 Hertz Style II - Fused Insulgrip® Mechanical Interlocks Rating Poles and Amps Wires Receptacle/ Connector Configuration* Maximum Voltage AC/DC Mechanical Interlock Mating Plug 30 3P 4W 600/250 HBL430MIFS2W HBL430PS2W 60 3P 4W 600/250 HBL460MIFS2W HBL460PS2W Pin and Sleeve Devices Pin and Sleeve Style II - Unfused Insulgrip® Mechanical Interlocks Rating Poles and Amps Wires Receptacle/ Connector Configuration* Maximum Voltage AC/DC Mechanical Interlock Mating Plug 30 3P 4W 600/250 HBL430MIS2W HBL430PS2W 60 3P 4W 600/250 HBL460MIS2W HBL460PS2W Note: 30A – 1 inch N.P.T. hub supplied; 60A – 1¼ inch hub supplied. * CAUTION: To avoid electrical shock, review premises carefully and DO NOT use if Pin and Sleeve configuration (design) is already in a circuit having a rating differing from the rating of this device. ** While in use or with cover closed. Auxiliary Contacts Catalog Number Auxiliary contact, normally open, A600 pilot duty, break before break. ACFSNO Auxiliary contact, normally closed, A600 pilot duty, break before break. ACFSNC ACFSNO Watertight Closure Plug Kits Description Catalog Number For 30A Circuit-Lock® unfused and fused Pin and Sleeve mechanical interlocks. For 60A Circuit-Lock® unfused and fused Pin and Sleeve mechanical interlocks. MICPK30 MICPK60 MICPK30 Replacement Mounting Feet Description Catalog Number Replacement mounting feet and screws for 30 and 60A fused mechanical interlocks. HBLRFT2• Note: • Package of 10 feet and 10 screws. Dimensions in Inches (mm) HBLRFT2 www.hubbell-wiring.com E-39 Insulgrip® Mechanical Interlock Description Pin and Sleeve Devices Pin and Sleeve Technical Information Specifications, HP Ratings and Dimensions Typical Specifications Performance Manufacturer’s Identification Hubbell HBL460MIFS2W. Description Fused Insulgrip® Pin and Sleeve Mechanical Interlock. Electrical Type 3 Pole + Earth. Rating 60A, 250VDC/600VAC. Configuration Per UL 1686 C1. Enclosure Type (UL 50) Outdoor - 4X (Watertight, Washdown) Indoor - 12K (Dust Tight, Falling Dirt). Ingress Protection IP66 Suitability. Certification UL Listed, CSA Certified. Electrical Dielectric Voltage Max. Working Voltage Current Interrupting Note: This device provides fused switched control of a plug connected load and includes an interlocking feature to prevent the plug from being disconnected or the door from opening while the receptacle is energized. The switch cannot be turned on until the plug is fully inserted. Withstands 3,000VAC Min. 250VDC/600VAC. Certified for current interrupting at full rated current and voltage. Short Circuit Withstand Rating Suitable for use on a circuit capable of delivering not more than 100,000 RMS symmetrical amperes at the voltage rating of receptacle. Operations Mechanical 10,000 cycles minimum. Mechanical Impact Resistance Terminal Identification Product Ratings Materials Part Base, Door and Handle Conduit Hub Enclosure Gasket and Shaft Seal Shaft and Mounting Inserts Ground Plate Enclosure Screws and Hinge Spring Hinge Pin Contact Carrier Mounting Material Valox® Zinc, 30A – 1 in., 60A – 1¼ in. N.P.T. Environmental Moisture Resistance Ingress Protection Flammability Operating Temperatures Neoprene Brass Galvanized Steel UV Resistance Stainless Steel Nickel-Plated Brass Thermoset Polyester Fuse Types In accordance with UL 746C. In accordance with UL, CSA and international conventions. Ratings are part of the external label and molded into the receptacle housing. External adjustable feet. Outdoor - 4X (Watertight, Washdown) Indoor - 12K (Dust-tight, Falling dirt). IP66 Suitability. UL94-5VA and V-0 Classification. Max. Continuous +60°C; Min. Continuous -40°C w/o impact. All exposed insulating materials are UV stabilized. UL Listed Class “J”. CSA Certified HRCI-J. Horsepower Ratings 30A Horsepower Ratings 60A Horsepower Ratings 3 Phase A.C. Standard 200-240V 3 480V 5 600V 7.5 3 Phase A.C. Standard 200-240V 7.5 480V 15 600V 15 Maximum* 7.5 15 20 Maximum* 15 30 40 Note: * Requires time delay fuses. Dimensions Insulgrip® Mechanical Interlock 7.27" (184.7) 10.18" (258.6) 9.31" (236.5) 7.19" (182.6) 1.51" (38.4) 30A 1.68" (42.7) 60A 3.60" (91.4) 11.46" (291.6) 12.37" (314.2) 15.03" (381.8) 14.48" (367.8) 15.36" (390.1) 4.00" (101.6) 30A 5.00" (127.0) 60A 8.43" (214.1) Note: 30A – 1 inch N.P.T. hub supplied; 60A – 1¼ inch hub supplied. Valox® is a trademark of SABIC Innovative Plastics, acquired from General Electric Company. E-40 www.hubbell-wiring.com Dimensions in Inches (mm)