IEC Pin & Sleeve Safety Interlock Receptacles Application 20, 30 and 60 Amp configurations available for maximum safety and protection against accidental shock. Reduce maintenance downtime. This design prohibits the making and breaking of plug and receptacle under load. The safety switch must be in the OFF position to do so. NEMA Enclosure Type 4X, 12K. Available in Top or Bottom Feed cable entry enclosure. Safety Interlock Ordering Table Amps Poles/Wires Voltage Catalog Number Top Feed 20 3P4W 3P4W 3P4W 3P4W 120/240VAC 3 0 240VAC 3 0 480VAC 3 0 600VAC PS420MIR12-W PS420MIR9-W PS420MIR7-W PS420MIR5-W 30 2P3W 3P4W 3P4W 3P4W 3P4W 3P4W 4P5W 4P5W 4P5W 120VAC 120/240VAC 3 0 240VAC 3 0 480VAC 3 0 600VAC 380/440VAC 30Y 120/208VAC 3 0Y 277/480VAC 3 0Y 347/600VAC PS330MIR4-W PS430MIR12-W PS430MIR9-W PS430MIR7-W PS430MIR5-W PS430MIR3-W PS530MIR9-W PS530MIR7-W PS530MIR5-W 60 2P3W 3P4W 3P4W 3P4W 3P4W 4P5W 4P5W 4P5W 120VAC 120/240VAC 3 0 240VAC 3 0 480VAC 3 0 600VAC 30Y120/208VAC 3 0Y 277/480VAC 3 0Y 347/600VAC PS360MIR6-W PS460MIR12-W PS460MIR9-W PS460MIR7-W PS460MIR5-W PS560MIR9-W PS560MIR7-W PS560MIR5-W Key Features Heavy-Duty Switch Handle: More durable and heavy-duty. Easier to activate due to beefy grip lever. Color-coded red and black handle to indicate "Power On" or "Power Off" from a distance. Switch entry into enclosure offset .to side and sealed to protect against moisture leakage. NEMA 4X 12K Enclosure: Protects against water/moisture penetration. All Thermoplastic Design: Impact, chemical and temperature resistant. Versatile Mounting Means: A variety of mounting positions available to accommodate any space requirements. Can be mounted directly to channel or strut. OSHA Lockout/Tagout Provisions: Helps comply with OSHA Lockout/Tagout requirements. Top and Bottom Feed Enclosure Options: Integrity of the NEMA 4X Enclosure not violated with unnecessary openings into the enclosure. Heavy-Duty Metal Gear Mechanism: High performance and durable design due to steel design. IEC 309-1, 309-2 Configurated Receptacle: Guaranteed interchangeability with other IEC 309-1, 309-2 manufacturer's products. Pass & Seymour Ptegrand Bottom Feed 20 3P4W 3P4W 3 0 240VAC 3 0 480VAC PS420MIR9-WBF PS420MIR7-WBF 30 3P4W 3P4W 3 0 240VAC 3 0 480VAC PS430MIR9-WBF PS430MIR7-WBF 60 3P4W 3P4W 3 0 240VAC 3 0 480VAC PS460MIR9-WBF PS460MIR7-WBF 20/30 Amp 60 Amp Pass & Seymour D legrand IEC Pin & Sleeve Mechanical Interlock Features & Benefits Top- or bottom-feed models offer installation flexibility and eliminate the need for time-consuming modifications like drilling and plugging that may nullify the NEMA 4X enclosure rating. Off-center cable entry directs condensation away from internal circuitry reducing risk of shorts and corrosion. Compact design doesn't protrude, avoids unnecessary knocks; allows for versatile mounting, and fits into standard I-beams and channels. Stainless steel captive screws speed up installation, minimize risk of lost parts, and resist corrosion. Exclusive circuit ID pad for fast identification of the motor circuit. Accepts preprinted labels or handwritten data. Non-conductive, watertight, * corrosion- and impact-resistant Valox" enclosure ensures NEMA 4X and 1 2 ratings, withstands the harshest industrial environments. Adjustable mounting feet provide optimum flexibility when mounting to equipment and walls. Feet can also be moved to center of unit, for instant strut- or pole-mounting without special brackets or harnesses. And our oversized foot * • design eliminates the need for washers. Mechanical Interlock Operating Sequence When there is no plug in the device, the lock tab is in the "off" position and prevents the lock gear from turning. The handle cannot be moved to the "on" position. 2. Upon inserting a plug, the lock tab moves from the "off" position, freeing the lock gear. 3. The handle can then be moved to the "on" position. This rotates the lock gear and engages the key on the plug to prevent it from being removed. At the same time, the rack is actuated and rotates the switch gear, turning on the switch and inducing power. 4. Returning the handle to the "off" position frees the lock gear, disengaging the plug key from the switch and allowing the plug to be removed. IEC Pin & Sleeve Mechanical Interlock Bass & Seymour Dtegrand Features & Benefits Handle meets OSHA Lockout/Tagout requirements. Heavy-duty, lever-style switch handle ensures a firm grip - even with wet, greasy hands. Black/red color-coded handle and highvisibility "ON/OFF" markings clearly indicate power supply status from a distance and from all angles. Handle enters enclosure from one side to minimize damage due to frontal impacts; entry is offset and sealed to prevent moisture contamination during washdowns. Label is color-coded to correspond with the voltage ratings of all mating IEC plugs for easy visual identification. Stainless steel cover retaining chain allows for easy installation and maintenance. . Durable brass/nickel-plated contacts ensure reliable, long-lasting electrical performance ana corrosion resistance. Completely interchangeable with all manufacturers' IEC 309-1 and IEC309-2 plugs. Auxiliary contacts are standard to simplify ordering, purchasing, inventory, and installation requirements. Patent-pending, tamper-resistant activating assembly and cover-integral switch mechanism protect against unauthorized overrides ensuring operator safety. Valox* is a registered trademark of the General Electric Co. J-ll Pass&Seymour Dlegrand IEC Pin & Sleeve Product Specifications Mechanical Interlock Product Specifications Part Material Performance Enclosure Cover Valox Enclosure Base Valox Enclosure Gasketing Neoprene Maximum Working Voltage: 600V RMS Switch Handle Valox Current Interrupting: Switch Handle Seal Neoprene Listed for current interrupting at full rated current and voltage. Mounting Feet Valox Mounting Feet Screws 300 Senes Stainless Steel Enclosure Assembly Screws 300 Series Stainless Steel Enclosure Assembly Inserts Brass Receptacle Lid Valox Receptacle Gasketing Neoprene Electrical: Dielectric Voltage Withstand: 3000V minimum •n irt Circuit V, itisMnding Rating: For use on circuit capable of delivering not more tha^ 10,000 RMS Amps at receptacle voltage rating. Operations: Mechanical: 15, 000 cycles Electrical: 10. 000 cycles Mechanical: Receptacle LKJ Hinge Spnng 300 Series Stainless Steel Receptacle Contact Carrier Polyamide 6 • -if ,!..i Resistance: Per UL 746C '-'r-i-ial Identification: Per UL, CSA. and IEC specifications. Product Identification: Identification and rating on external and internal labels. External adjustable feet with live (5) positions. Receptacle Sleeves Brass/Nickel-Plated Mounting: Receptacle Terminal Screws Zinc-Plated Steel Environmental: Moisture Resistance: NEMA Enclosure Type 4X (watertight, hosedown); 12K (dusttight, falling dirt); IP67. Flammability: UL 94 5VA and VO Classification. Operating Temperature: Maximum continuous 60'C Minimum continuous; -50'C UV Resistance: All enclosure material UV stabilized Horsepower Ratings Part Number Amps Rating Horsepower Rating PS420MIR12-W PS420MIR9-W PS420M1R7-W PS420MIR5-W 20 20 20 20 120/240VAC 30240VAC 3o480VAC 3o600VAC 1 ® 1 20V; 2 @ 208-240V L-L 5 10 15 PS430MIR12-W PS430MIR9-W PS430MIR7-W PS430MIR5-W PS530MIR9-W PS530MIR7-W PS530MIR5-W 30 30 30 30 30 30 30 120/240VAC 30240VAC 30480VAC 3o600VAC 3o Y 120/208 VAC 30Y277/480VAC 30Y347/600VAC 2® 120V; 3@208-240V L-L 7.5 15 20 5 15 20 PS460MIR12-W PS460MIR9-W PS460MIR7-W PS460MIR5-W PS560MIR9-W PS560MIR7-W PS560MIR5-W 60 60 60 60 60 60 60 120/240VAC 30240VAC 30480VAC 3o600VAC 3o Y 120/208 VAC 30Y277/480VAC 3oY347'600VAC 3® 120V; 7.5@208-240V L-L 15 30 40 15 30 40 J-14