RS22 SERIES THE HUMIDITY SERIES Intempco's Complete Line of Quality Engineered Programmable Humidity/Temperature Sensors humidity Integrated sensor/transmitter construction Factory calibration eliminates need for costly humidity calibration Hermetically sealed electronics ensures reliable performance in the harshest environments Digital re-calibration and re-programming of output via PC and without the use of potentiometers Auto-calibration of electronics provides stable and accurate output with minimum need for periodic calibrations Visit our website for our complete online products catalog www.intempco.com PHP01 SERIES Programmable Humidity Probes Product Features • Low cost OEM and HVAC relative humidity probe • Output is 4-20 mA standard • Factory calibrated 0% to 100%RH • Digital re-calibration, no potentiometers • Digitally re-programmable • Optional temperature output, RTD or thermistor • High accuracy and long term stability • Integrated hermetically sealed RH microprocessor based transmitter • Built-in temperature compensation • PLC compatible • Sensor fail detection feature • Self calibration of transmitter electronics Description The PHP01 is a Programmable Relative Humidity Probe which provides an accurate analog output directly proportional to 0...100 % RH. Using Intempco’s patented MISTMicroprocessor Integrated Sensor Transmitter™ technology, PHP01 feature digital zero and span adjustment and can be re-calibrated by the use of PHP01-PKit communication module and software. The PHP01 shows an excellent linearity and accuracy of ± 2 % from 5...95 % RH with two point calibration but units are calibrated to ± 3% accuracy. They comes factory calibrated from 0..100% for RH with a standard output of 4...20 mA but 0...1 V or 0...10 V are also available. Optional temperature output, various RTD bulbs or thermistors, is also available.The PHP01 utilizes a thin-film polymer capacitive humidity sensor that provides excellent stability and fast response. The sensor fully recovers from condensation. The construction of PHP01 is very robust and long lasting. The unit is potted and has completely hermetically sealed electronics. There are no accessible parts inside the housing. Three standard models are available: PVC probe only, probe with 3/4” NPT fitting and probe with flange. They come standard with 10 feet of PVC insulated extension cable and dust filter cap made from porous plastic, but sintered stainless cap is also available. For non-standard units, refer to Custom Builder. The compact size, durability and high accuracy makes it ideal choice for all applications that require the monitoring and controlling of humidity and temperature, including a variety of OEM and HVAC applications. Application / Process Notes • Climate rooms • Greenhouses • Warehouses • HVAC installations • Energy management • OEM and HVAC equipment PHP01-2 Online ordering, visit : www.intempco.com PHP01 SERIES Standard Humidity Probes, 4-20 mA Output Note : Standard PHP01 probes have a 4-20 mA output ( Span 0% to 100% RH ) calibibrated to accuracy of ± 3% RH ( from 5% to 95% RH ) PHP01- with PVC Housing, Porous Plastic Filter and 10 ft ( 3 m ) of PVC Cable 0.68 ” PVC ( 17 ) 0.72 ” ( 18 ) 4.0 ” ( 100 ) 10.0 ’ (3m) Model : PHP01-H3-P-1-PV120 1.80 ” ( 46 ) w / Plastic Filter PHP01- with PVC Housing, Sintered Stainless Steel Filter and 10 ft ( 3 m ) of PVC Cable 0.68 ” ( 17 ) 4.0 ” ( 100 ) 10.0 ’ (3m) Model : PHP01-H3-P-2-PV120 0.86 ” ( 22 ) w / Stainless Filter PHP01- with PVC Housing, PVC 3/4 ” NPT Fitting and 10 ft ( 3 m ) of PVC Cable 1.0 ” ( 25 ) 0.68 ” PVC ( 17 ) 0.72 ” ( 18 ) 4.0 ” ( 100 ) 10.0 ’ (3m) Model : PHP01-H3-P-1-F34-PV120 PHP01-H3-P-2-F34-PV120 1.80 ” ( 46 ) w / Plastic Filter w / Stainless Filter PHP01- with PVC Housing, PVC 1.5 ” Flange and 10 ft ( 3 m ) of PVC Cable 1.50 ” OD ( 25 ) 0.68 ” PVC ( 17 ) 0.72 ” ( 18 ) 10.0 ’ (3m) Model : PHP01-H3-P-1-F15-PV120 PHP01-H3-P-2-F15-PV120 1.0 ” ( 25 ) 4.0 ” ( 100 ) 1.80 ” ( 46 ) 0.19 ” ( 5 ) dia. 3 holes EQSP on 1.09 ” dia w / Plastic Filter w / Stainless Filter Online ordering, visit : www.intempco.com PHP01-3 PHP01 SERIES Programmable Humidity Probes, 4-20mA Output Note : Standard PHP01 probes have a 4-20 mA output ( Span 0% to 100% RH ) calibibrated to accuracy of ± 3% RH ( from 5% to 95% RH ) PHP01- with PVC Housing, Receptacle and Connector with Screws 0.27 ” (7) 0.68 ” PVC ( 17 ) 0.72 ” ( 18 ) 4.0 ” ( 100 ) 0.27 ” (7) Model : PHP01-H3-P-1-CA PHP01-H3-P-2-CA 1.80 ” ( 46 ) w / Plastic Filter w / Stainless Filter PHP01- with PVC Housing, Receptacle and Molded Connector with 10 ft ( 3 m ) of PVC Cable 0.27 ” (7) 0.68 ” PVC ( 17 ) 0.72 ” ( 18 ) 4.0 ” ( 100 ) 10.0 ’ (3m) Model : PHP01-H3-P-1-BA PHP01-H3-P-2-BA 1.80 ” ( 46 ) w / Plastic Filter w / Stainless Filter PHP01- with Stainless Steel Housing, Sintered Stainless Steel Filter and 10 ft ( 3 m ) of PVC Cable with SS Armor 0.72 ” ( 18 ) 4.0 ” ( 100 ) 10.0 ’ (3m) Model : 0.86 ” ( 22 ) PHP01-H3-S-2-TA120 w / Stainless Filter PHP01- with Stainless Steel Housing, Sintered Stainless Steel Filter and 10 ft ( 3 m ) of PVC Cable 0.72 ” ( 18 ) 4.0 ” ( 100 ) 10.0 ’ (3m) Model : PHP01-4 PHP01-H3-S-2-PV120 w / Stainless Filter Online ordering, visit : www.intempco.com 0.86 ” ( 22 ) PHP01 SERIES Standard Humidity Probes, 4-20 mA Output Note : Standard PHP01 probes have a 4-20 mA output ( Span 0% to 100% RH ) calibibrated to accuracy of ± 3% RH ( from 5% to 95% RH ) PHP01- with Stainless Steel Housing, Sintered Stainless Steel Filter, Receptacle and Connector with Screws 0.72 ” ( 18 ) 4.0 ” ( 100 ) 10.0 ’ (3m) Model : PHP01-H3-S-2-CA 0.86 ” ( 22 ) w / Stainless Filter PHP01- with Stainless Steel Housing, Sintered Stainless Steel Filter, Receptacle and Molded Connector with 10 ft ( 3 m ) of PVC Cable 0.27 ” (7) 0.72 ” ( 18 ) 10.0 ’ (3m) Model : PHP01-H3-S-2-BA120 4.0 ” ( 100 ) 0.86 ” ( 22 ) w/ Stainless Filter PHP01- with Stainless Steel Housing, Sintered Stainless Steel Filter, 1/2 ” NPT Fitting and 10 ft ( 3 m ) of PVC Cable 1.0 ” ( 25 ) 0.72 ” ( 18 ) 4.0 ” ( 100 ) 10.0 ’ (3m) Model : PHP01-H3-S-2-F12-PV120 0.86 ” ( 22 ) w / Stainless Filter PHP01- with Stainless Steel Housing, Sintered Stainless Steel Filter, 1.5 ” SS Flange and 10 ft ( 3 m ) of PVC Cable 1.50 ” OD ( 25 ) 0.72 ” ( 18 ) 10.0 ’ (3m) Model : PHP01-H3-S-F15-2-PV120 1.0 ” ( 25 ) 4.0 ” ( 100 ) 0.19 ” ( 5 ) dia. 3 holes EQSP on 1.09 ” dia 0.86 ” ( 22 ) w / Stainless Filter Online ordering, visit : www.intempco.com PHP01-5 PHP01 SERIES Programmable Humidity Probes, Analog Output 0.27 ” (7) Shown with HPDE Dust cover Filter 0.68 ” PVC ( 17 ) 0.72 ” ( 18 ) 10.0 ’ (3m) “ L” 4.0 ” STD. ( 100 ) 1.80 ” ( 46 ) 1.50 ” OD ( 25 ) 0.72 ” ( 18 ) 1.0 ” ( 25 ) “E” 0.19 ” ( 5 ) dia. 3 holes EQSP on 1.09 dia 0.86 ” ( 22 ) “ L” 4.0 ” STD. ( 100 ) Shown with Sintered Stainless Steel Filter 0.72 ” ( 18 ) 0.86 ” ( 22 ) “ L” 4.0 ” STD. ( 100 ) “E” Custom Builder : MODEL BOX1 BOX2 BOX3 BOX4 BOX5 BOX6 BOX7 BOX8 BOX10 BOX9 BOX11 PHP01 - _ _ - H - _ - _ - 6 - _ - _ - _ _ _ - _ _ _ _ _ - _ _ _ - _ _ BOX1 CODE Temperature Output BOX4 CODE Humidity Output RH Linear BOX9 CODE Lead Wire Insulation “ E ” N0 No Temperature Output A 4 - 20 mA Loop Powered, 2-wire PV _ _ _ P2 Pt 100 @ 0 oC, α = 0.00385 Class B, 2-wire C 4 - 20 mA Source Powered, 3-wire PVC Insulation, 90 oC ( 195 oF ) max. E 0 - 5 VDC TF _ _ _ Teflon Insulation, 200 oC ( 392 oF ) max. P3 Pt 100 @ 0 oC, α = 0.00385 Class B, 3-wire G 0 - 10 VDC TA _ _ _ Teflon with SS Armor, 200 oC ( 392 oF ) max. Q2 Pt 1000 @ 0 oC, α = 0.00385 Class B, 2-wire TB _ _ _ Teflon with SS Overbraid, 200 oC ( 392 oF ) max. Q3 Pt 1000 @ 0 oC, α = 0.00385 Class B, 3-wire TH* Thermistor ( 1K, 2K, 5K,10K @ 0 oC ) * Code TH is for thermistor type. Many available. Specfiy type by R-T curve or supplier P/N. Notes: 1. For non-standard temperature outputs consult factory. For current or voltage temperature outputs is PHP02 brochure. BOX3 CODE Humidity Output Accuracy 5% RH to 95%RH 2 ± 2 % RH from -18oC to +82oC 3 ± 3 % RH from -29oC to +82oC 5 ± 5 % RH from -29oC to +82oC Other outputs available. Consult Factory. BOX6 CODE Probe Material P PVC S 316 Stainless Steel Other materials available. Consult factory. BOX7 CODE Male Receptable and Molded Connector w/Cable CA Male Receptable and Connector w/Screws (no cable) 1 Pourous Plastic HPDE *Standard cable length is 10 ft (3m), i.e. Code BA120 2 Sintered Stainless Steel Other lengths are available, but delivery is longer. If longer cable lengths needed, use connector Code CA. Other materials available. Consult factory. BOX8 CODE Fitting Type BOX10 CODE Probe Length “ L ” N None ___ In 0.1 inch increments Ex.: 040 = 4.0 ” long Ex.: 065 = 6.5 ” long F12 Fixed 1/ 2 ” NPT (for SS probe) F34 Fixed 3/4” NPT (for PVC probe) F15 Flange, 1.5 ” O.D. Standard probe length is 4.0, i.e. Code 040. BOX11 CODE Options PHP01 Programming Kit __ None ( leave blank ) Model : PHP01-PKit C1 Calibration certificate ( specify 1 point ) C2 Calibration certificate ( specify 2 points ) The protramming kit is needed to re-calibrate or re-scales the PHP01 Humidity Probes. It includes software, RS-232 module and wall adapter. PHP01-6 BA _ _ _* Dust Filter Material Note: 1. Standard PHP01 probes have a 4-20 mA output ( Span 0% to 100% RH ) calibibrated to accuracy of ± 3% RH ( from 5% to 95% RH ) Note : 1. Specify wire length in inches ( 999 ” max. ) E.g.: TF060 =Teflon wire, 60 ” long Online ordering, visit : www.intempco.com PHP01 SERIES Programmable Humidity Probes, Analog Output Technical Specifications : Humidity Sensing Element : Thermoset polymer thin film capacitive RH sensor Calibrated Range : 5 % to 95 % RH System Accuracy : ± 2 %, ±3 %, or ± 5 % RH ( 5 % to 95 % RH range ) Supply Voltage : 12-36 VDC, polarity protected Power Requirement : 40 mA max @ 24 VDC Supply Voltage Effect : ± 0.002 RH/volt ( negligable ) from 12-36 VDC Output : 4–20 mA, loop powered 2-wire, 0 to 100% RH 4–20 mA, source powered 3-wire, 0 to 100% RH 0–5 VDC, 0 to 100% RH 0–10 VDC, 0 to 100% RH Repeatability : ± 0.5 % RH Linearity : ± 1 % RH Hysteresis : ± 1 % RH of operating humidity span Sensor Stability : ± 1 % RH typical at 50% RH in 1 year Temperature Effect : ± 0.03 % RH/0 °C ± 1 % RH at +10 °C to +85 °C ( -40°F to +185 °F ) Temperature Comp.: - 23 °C to +85 °C ( -10°F to +185 °F ) Operating Environment : - 40 °C to +85 °C ( -40°F to +185 °F ) non-condensing ( 0 % to 95 % RH ) Storage Environment : - 50 °C to +85 °C ( -58°F to +185 °F ) non-condensing Zero and Span Adjust. : Digital recalibration via PHP-Config1 Module and PC Sensor Break Indication : Upscale to 23 mA Polarity Protection : Diode reverse polarity protected Sensor Protection : HPDE dust cover 60 micron or sintered SS dust cover 60 micron ( optional ) Sensor Housing : PVC or SS316 ( optional ) Mounting : Flange, 1/ 2 ” NPT fitting, 3/ 4 ” NPT fitting Pressure Ratings : 50 psig for PVC housing and 100 psig for SS housing Probe Connections : Various extension cables, molded connectors with extension cable and connector with screws Protection : Electronics IP67 ( NEMA 6X ), sensor IP20 and with dust filter IP50 Online ordering, visit : www.intempco.com PHP01-7 HVAC SERIES Humidity-Temperature Transmitter HTX01 WALL MOUNT HTX02 DUCT MOUNT Product Features • Low Cost • On-Board Zero And Span Adjustments • Rugged design using Solid State Sensors • High Accuracy (± 3% over 0 to 90% RH Standard) • 2 Wire, Loop powered Operation (4-20 mA Output) • Temperature Compensated Humidity Measurement • Factory Calibrated ( 0 - 100% RH Standard, Custom Ranges Available ) • Integrated Loop powered Temperature Transmitter Available Description Overview The INTEMPCO HTX series humidity transmitters offer high accuracy, low cost humidity, and temperature measurement that can withstand tough industrial and HVAC applications. The rugged solid state sensor has high chemical contamination resistance and handles extreme ventilation conditions, like swimming pool environments, with ease. Even water immersion of the sensor will not damage it! The HTX series humidity / temperature transmitters are designed for use in energy management, environmental and process control industries. They utilize a polymer based humidity sensor, among the most stable available. The accuracy is ±3% over 0 - 90% RH. Thermistor or RTD output option is also available. Online ordering, visit : www.intempco.com PHP01-8 HVAC SERIES Humidity-Temperature Transmitter HTX01 WALL MOUNT 1.19” Humidity Transmitter 2.64” Power Input 12 - 36 VDC Humidity Output 4-20mA two-wire Humidity Accuracy ±3% RH Max. Over 0-90% RH at 25°C. Humidity Stability ±1% RH Typical at 50% RH in 5 Years. Time Constant 50 sec. in air at 10ft/sec. Operating Environment -23°C to 85°C (-10°F to 185°F) non-condensing Storage Environment -50°C to 85°C (-58°F to 185°F) non-condensing Recommended R load 100 ohm @12 VDC 500 ohm @ 24 VDC 4.93” 3.75” Temperature Transmitter Power Input 12 - 36 VDC Temperature Output 4-20mA two-wire Temperature Accuracy ±0.3°C (0.5°F) at room Temp. or ±0.15°C (0.25°F) Special Temperature Stability ±0.1°C Typical at room Temp. per 5 years Time Constant 50 sec. in air at 10ft/sec. Operating Environment -23°C to 85°C (-10°F to 185°F) non-condensing Storage Environment -50°C to 85°C (-58°F to 185°F) non-condensing Recommended R load 100 ohm @12 VDC 500 ohm @ 24 VDC 2.0 0” 6.00” .68” Dia. 6.00” L HTX02 DUCT MOUNT MODEL NUMBER ENCLOSURE TYPE TEMPERATURE SENSOR OPTION HTX Enclosure Type CODE CODE Temperature Sensor Option Wall Mount, Executive 01 0 None Wall Mount, Space 01A A 4-20mA, 0-50°C Duct Mount, NEMA 4 02 B 4-20mA, SPECIFY RANGE Duct Mount, General 02A C Pt 100 ohm DIN 43760 PHP01-9 D 1000 ohm DIN 43760 E 10,000 ohm THERMISTOR F 3,000 ohm THERMISTOR G THERMISTOR, OTHER SPECIFY Online ordering, visit : www.intempco.com HVAC SERIES Temperature Monotoring Sensors and Transmitter EXTERIOR WALL MOUNT INTERIOR WALL MOUNT Product Features • Low Cost • High Accuracy • Factory Calibrated • 2 Wire, Loop powered Operation(4-20 mA Output) Available Description Overview The INTEMPCO HVAC series ambient temperature sensors offer high accuracy, low costtemperature measurement that can withstand tough industrial and HVAC applications for ducts. The HVAC series temperature sensor/transmitters are designed for use in energy management, environmental and process control industries. They utilize a Thermistor or RTD. As specified by customer and can have a 4-20mA output on custom ranges. The rugged stainless steel sensor has high chemical contamination resistance and handles extreme ventilation conditions. Interior wall mount model is esthetic and blends in well with today’s modern decor The RTD transmitter combination supplies the highest accuracy for HVAC purposes as well as dalicate process control. Online ordering, visit : www.intempco.com PHP01-10 HVAC SERIES Temperature Monotoring Sensors and Transmitter HTX01 WALL MOUNT Temperature Transmitter Option A or B 2.64” Power Input 12 - 36 VDC Temperature Output 4-20mA two-wire Temperature Accuracy ±0.3°C (0.5°F) at room Temp. or ±0.15°C (0.25°F) Special Temperature Stability ±0.1°C Typical at room Temp. per 5 years Time Constant 50 sec. in air at 10ft/sec. Operating Environment -23°C to 85°C (-10°F to 185°F) non-condensing Storage Environment -50°C to 85°C (-58°F to 185°F) non-condensing Recommended R load 100 ohm @12 VDC 500 ohm @ 24 VDC 4.93” 2.0 0” 3.75” 1.19” 3.75” 2.0 0” .250” Dia. 2.50” L 3.75” 3.75” .250” Dia. 6.00” L DUCT MOUNT NEMA 4X MODEL NUMBER ENCLOSURE TYPE EXTERIOR WALL MOUNT TEMPERATURE SENSOR OPTION R200 Enclosure Type CODE CODE Temperature Sensor Option Wall Mount, Exterior 01 A 4-20mA, 0-50°C Wall Mount, Interior 01A B 4-20mA, SPECIFY RANGE Duct Mount, NEMA 4 02 C Pt 100 ohm DIN 43760 Duct Mount, General 02A D 1000 ohm DIN 43760 E 10,000 ohm THERMISTOR PHP01-11 F 3,000 ohm THERMISTOR G THERMISTOR, OTHER SPECIFY Online ordering, visit : www.intempco.com