FieldPower® power bus system Product Information Decentralised Automation Factory automation Factory automation FieldPower® Drive – the system partner The standard for decentralised drive systems FieldPower® has emerged as the proven power distribution solution for decentralised motor management; it has supported well known providers in automotive production, logistics halls and airports. The reasons are clear: the variable FieldPower® contact module supports the pre-assembly of cable assemblies and also enables quick, precise installation at the construction site. The installation work can be carried out by workers who are not trained electricians. The modular design makes it easier to conduct functionality and performance tests. FieldPower® offers many solutions for dealing with changes in the facility or factory layout. The consensus among users is that project planning and execution is significantly easier when using FieldPower®. It allows them to exploit the cost benefits of decentralisation. For further information, please visit www.weidmueller.com/int/fieldpower_drive Partners and references for drive systems •MSF Vathauer Antriebstechnik provides motor starters and frequency converters which are simply attached to the FieldPower® Box. www.weidmueller.com/int/msf •SEW-Eurodrive has designed a solution for intra-logistics – the MOVIFITbasic. The FieldPower® Terminal is integrated into the power connection. www.weidmueller.com/int/sew •Siemens is using FieldPower® for their Solution Partnership in the new motor controller devices G120D, G110D and M200D.. www.weidmueller.com/int/siemens • The Rapid Link system from Eaton-Moeller uses Application-specific solutions FieldPower® and conventional round cables for power distribution. www.weidmueller.com/int/eaton Take advantage of our FieldPower® Drive •Lenze offers its new 8400-series of decentralised pre-assembled cables and RockStar® HQ connectors (in compliance with ISO 23570 / frequency converters with FieldPower®-compatible DESINA) for connecting decentralised motor HQ connectors. controller devices quickly and conveniently. www.weidmueller.com/int/lenze Quick commissioning with easy measuring of impedance In order to protect the facility, the protective device must be triggered whenever there is a short circuit. This is possible when the impedance on the power bus line is constant and minimal. Measurements are used to verify this. Simple "in-and-out wiring" – though ostensibly cheaper – can turn into an expensive solution since motor controller devices must be disconnected during the measurement process and then re-connected. FieldPower®, however, features an uncut power line with constant impedance. The pluggable feature also makes this very easy to prove. Modular power bus segments •Pre-assembled cable segments customised for the facility modules are ideal for projects with accelerated timelines. They are particularly well suited for such projects because they need only be plugged in at the construction site. •The power bus can also be used in segments with various implementations. Extending and repairing the power bus An uncut power bus can be terminated wherever needed. The wire ends should then be protected using heat-shrink tubes. The power bus can be continued or enlarged quite easily because it has a full rated capacity of 41 A / 6 mm² using its PUSH IN contacts. M M M The standard product assortment is described at www.weidmueller.com/int/fieldpower_drive Power supply lines •RockStar® HQ 4/2 or HQ5 •Plastic housings, angled and straight •Unshielded lines Motor supply lines for motor starters •RockStar® HQ8 •Plastic housings, angled and straight •Unshielded lines Motor supply lines for frequency converters •RockStar® HQ8 EMC-optimised •Metal housings, angled and straight •Shielded lines We would be happy to prepare customised cables for you when larger quantities are required. Please send requests to rfq.middle-hub@weidmueller.de Factory automation Factory automation FieldPower® Drive – the system partner The FieldPower® Box with motor starter and frequency converter – an integrated drive solution The FieldPower® connectivity modules and motorcontroller modules can be combined as needed – allowing Weidmüller and MSF Vathauer Antriebstechnik to develop a bold, innovative solution for boosting the efficiency of decentralised factory automation. The motor starter is attached directly to the FieldPower Box in order to integrate the power distribution and motor control functions into one enclosure located on-site. The result is dramatically reduced installation and commissioning times. Facility planning is also accelerated with this integrated and flexible drive solution. ® The FieldPower® Box with motor controller is available in different functional variants each with standardised connection interfaces. Depending on the variant, either one or two three-phase motors can be connected using preassembled cables to the IEC-23570-compliant RockStar® HQ connectors. Pluggable M12 connections provide control Motor management variants • Electronic direct starter for one motor up to 2.2 kW • Electronic direct starter for two motors up to 0.75 kW • Electronic soft starter for one motor up to 2.2 kW • Electronic soft starter for two motors up to 0.75 kW • Electronic reversible soft starter up to 2.2 kW • VECTOR frequency converter up to 2.2 kW options for an AS interface, sensor system and handheld controller. On the operating side, LEDs indicate the operational status, the ASi status and also an error alert when the motor has overheated. The integrated VECTOR FieldPower® frequency converter is a unique variant of this innovative drive solution; it is a compact, decentralised unit intended for power distribution and motor control. Its standardsed communication port (RS 232 with M12 plug) provides a quicker and more efficient access method for modifying parameters on the frequency converter. The configuration process is carried out using either PC-based parameterisation software or a plaintext operator interface. Controller variants • AS-Interface • Binary 24 V DC • Handheld controller Also featuring • Brake control • Thermal motor protection Layout variants •Power bus integrated with HQ8 motor socket Motor starter with HQ8 plastic housing for unshielded cables Frequency converter with HQ8 metal housing for shielded cables • Motor integrated with HQ4/2 power plug All variants with HQ4/2 plastic housing for unshielded cables For further information, please visit www.weidmueller.com/int/msf 400 V ∼ 3 ph 480 V ∼ 3 ph HQ 4/2 RockStar® HQ connector according to IEC 23570 and assembled cables •Power supply lines with HQ 4/2 connectors Plastic housings, angled and straight Unshielded lines, 4- and 5-wire, from 1.5 – 4 mm² • Motor supply lines with HQ8 connectors Plastic housings, angled and straight Unshielded lines, 4- and 8-wire, from 1.5 – 4 mm² • Motor supply lines with HQ8 connectors, EMC Metal housings, angled and straight Unshielded lines, 4- and 8-wire, from 1.5 – 2.5 mm² M 3∼ HQ 8 Additional information can be found in the Weidmüller Catalogue 3 M12 plug cables • 3-pole for sensor connection in IP68 • Angled or straight in different lengths • Including two identification sleeves Coupling between AS interface ribbon cable and M12 • Coupling module from ribbon cable to 2-m round cable • Customisable M12 socket Additional information can be found in the Weidmüller Catalogue 8 4 Ansteuerungsvarianten • AS-Interface • Binär 24 VDC. MSF Vathauer Antriebstechnik •GmbH Handbedien-Gerät & Co KG Außerdem or more than 30 years, MSF Vathauer •Antriebstechnik Bremsenansteuerung GmbH & Co. KG has been a single-source provider of mechanical, electrical • Thermischer Motorschutz and electronic drives. In cooperation with Weidmüller, an innovative design for decentralised motor control was developed by integrating a motor starter or frequency converter into the FieldPower® Box. Contact: http://www.msf-technik.de 5 FieldPower® Drive FieldPower® Drive Power lines Description Order No. Type Qty. HQ – socket (female) Pin assignments FieldPower® plug Wire assignments Length 1 Length 2 Line type Protection degree Used for* Siemens M200D 8000005228 8000005229 PVC power feed line with FieldPower® plug and HQ4 2 socket for L1, L2, L3, PE PVC power feed line with FieldPower® plug and HQ4 2 socket for L1, L2, L3, PE PVC power feed line with FieldPower® plug and HQ5 socket for L1, L2, L3, PE FPL 4G2.5/P/Q4KW/2 FPL 4G2.5/P/Q4KW/5 1 1 8000005264 8000005230 FPL 4G2.5/PD/Q4KW/2+2 FPL 4G2.5/PD/Q4KW/2+5 1 1 8000005294 8000005295 FPL 4G2.5/P/Q4MG/2 FPL 4G2.5/P/Q4MG/5 1 1 8000005296 8000005297 8000005298 8000005300 8000005233 1059190000 FPL 4G2.5/PD/Q4MG/2+2 FPL 4G2.5/PD/Q4MG/2+5 FPL 4G2.5/PD/Q4MG/2+7.5 FPL 4G2.5/PD/Q4MG/2+15 FPL 5G2.5/P/Q5/2 FPL 4G2.5/P/F/3 1 1 1 1 1 Plastic housing, angled 1 x HQ4 2 Plastic housing, angled 2 x HQ4 2 Metal housing, straight 1 x HQ4 2 Metal housing, straight 2 x HQ4 2 Plastic housing, straight 1 x HQ5 1 1059170000 FPL 4G2.5/PD/F/3+3 11 = nc 1 = L1 PTDS 4 3 = L3 Technical data HQ can be found in the Catalog 3, RockStar® - Heavy Duty Connectors Abbreviations used: 4 = nc PTS 4 PE 12 = nc 2 = L2 PTDS 4 11 = nc 1 = L1 1 = L1 = PE 2 = L2 3 = L3 5 = nc PTS 4 4=N 1 2 3 gn/ye = L1 = L2 = L3 = PE 1 2 3 gn/ye = L1 = L2 = L3 = PE 1 2 3 4 gn/ye = L1 = L2 = L3 =N = PE 1 H2.5/14D BL 2m 5m - 2m 2m 2m 5m 2m 5m - 2m 2m 2m 2m 2m 2m 5m 7.5 m 15 m - 3m PTS 4 LIS 2.5 M4V Two lines Note 4 = nc PTS 4 PE 12 = nc 2 = L2 Wire preparation One line PVC power feed line with FieldPower® plug and processed wires 3 = L3 PTDS 4 1 2 3 gn/ye = L1 = L2 = L3 = PE 3m Ölflex Classic 110 4G2,5 or similar IP65 Ölflex Classic 110 4G2,5 or similar IP54 Ölflex Classic 110 4G2,5 or similar IP65 Ölflex Classic 110 4G2,5 or similar IP54 Ölflex Classic 110 5G2,5 or similar IP65 Ölflex Classic 110 4G2,5 or similar IP65 Ölflex Classic 110 4G2,5 or similar IP54 - 3m Q4KW HQ4/2 socket, plastic, angled F Wire-end ferrules 2 Length 2 m FPLFieldPower line 4G2.5 4 wires, 2.5 mm², with PE P PTS 4 plug ® Lenze Protec 8400 x x Siemens G120D G110D x x MSF Vector on FieldPower® - SEW MOVIMOT SEW MOVIFITbasic - MSF Switch on FieldPower® - - Eaton-Moeller Rapid Link RA-SP... - Eaton-Moeller Rapid Link RA-MO... - - x x x x - - - - - - - - - x x - - - - - - - - x x x x - - - - - x x - - - - - x - - - - - - - - x - - - - Eaton-Moeller Rapid Link RA-MO... - Eaton-Moeller Rapid Link RA-SP... - - x x - x x Eaton-Moeller Rapid Link RA-MO... - Eaton-Moeller Rapid Link RA-SP... - x x - x x *) - You should check the current documentation from the manufacturer to verify that the motor controller devices are compatible. - The cross-section and wire count depends on the particular application. - We reserve the right to make technical changes. Motor lines Description PVC motor line for starters with HQ8 plug for U, V, W, PE, thermistor, brake Note Technical data HQ can be found in the Catalog 3, RockStar® - Heavy Duty Connectors Order No. Type Qty. 8000005235 8000005237 FPL 8G1.5/Q8KW/2 FPL 8G1.5/Q8KW/5 1 1 8000005238 8000005239 FPL 8G1.5/Q8KG/2 FPL 8G1.5/Q8KG/5 1 1 Abbreviations used: FPL 4G1.5 Q8KW Q8KG 2 HQ 8 – plug (male) Pin assignments Plastic housing, angled HQ8 Plastic housing, straight HQ8 8 = TF 5 = TF = PE 3=W 2 = nc Line end 7=V 6 = BR 4 = BR Open 1=U Wire assignments Length 1 Length 2 1 2 3 4 5 6 7 gn/ye 2m 5m - 2m 5m - =U =V =W = BR = BR = TF = TF = PE Line type Ölflex Classic 110 8G1,5 or similar Protection degree IP65 Siemens M200D Lenze Protec 8400 x x Siemens G120D G110D - - MSF Switch auf FieldPower® x x - - - x x Used for* MSF SEW Vector auf MOVIMOT FieldPower® - - - SEW MOVIFITbasic *) - You should check the current documentation from the manufacturer to verify that the motor controller devices are compatible. - The cross-section and wire count depends on the particular application. - We reserve the right to make technical changes. FieldPower® line 4 Adern, 1.5 mm², mit PE HQ8 plug, plastic, angled HQ8 plug, plastic, straight Length 2 m EMC motor lines Description PVC shielded motor line for frequency converters with HQ8 plug for U, V, W, PE, thermistor, brake Note Technical data HQ can be found in the Catalog 3, RockStar® - Heavy Duty Connectors Order No. Type Qty. HQ 8 – plug (male) Pin assignments 8000005240 8000005241 FPL 4G1.5C4/Q8MW/2 FPL 4G1.5C4/Q8MW/5 1 1 8000005242 8000005243 FPL 4G1.5C4/Q8MG/2 FPL 4G1.5C4/Q8MG/5 1 1 Abbreviations used: FPLFieldPower® line 4G1.5C4 4 wires, 1.5mm², with PE, shielded, additional 4 wires (2x2x0.75mm²) shielded in pairs Q8MW HQ8 plug, metal, angled (EMC cable gland) Q8MG HQ8 plug, metal, straight (EMC cable gland) 2 Length 2 m EMC metal housing, angled HQ8 EMC metal housing, straight HQ8 8 = TF 5 = TF = PE 3=W 2 = nc Line end 7=V 6 = BR 4 = BR Open 1=U Wire assignments Length 1 Length 2 1 =U 2 =V 3 =W 5 = BR 6 = BR 7 = TF 8 = TF gn/ye = PE 2m 5m - 2m 5m - Line type Protection degree Ölflex Servo 709 CY 4G1.5 IP65 + 2x2x0.75 or similar Siemens M200D Lenze Protec 8400 - Siemens G120D G110D x x x x MSF Switch auf FieldPower® - - - x x - Used for* MSF SEW Vector auf MOVIMOT FieldPower® x x - x x - SEW MOVIFITbasic *) - You should check the current documentation from the manufacturer to verify that the motor controller devices are compatible. - The cross-section and wire count depends on the particular application. - We reserve the right to make technical changes. You can find further versions at www.weidmueller.com/int/fieldpower_drive 6 7 FPL motor lines FPL motor lines with HQ8 plug-in connectors in accordance with IEC 23750 • Wire diameter 2.5 mm² • 4-conductor for U, V, W, PE • 7-conductor for U, V, W, PE, brake control • Unshielded • Shielded • Lengths of 3 m, 5 m or 10 m 8 FPL motor lines FPL 4G2.5/Q8KW FPL 4G2.5C/Q8MW 4-conductor unshielded 4-conductor shielded Pin assignments 8 = nc 7 =V 5 = nc 6 = nc = PE 3 =W Pin 1 2 3 4 5 6 7 8 PE 4 = nc 1 =U 2 = nc Conductor 1 – 3 – – – 2 – gr./yell. Assignment U – W – – – V – PE Technical data Contact insert Contact surface Housing Cable gland Rated voltage U0/U Rated current Protection class (in plugged state) Line type Ordering data Type FPL 4G2.5/Q8KW/3 FPL 4G2.5/Q8KW/5 FPL 4G2.5/Q8KW/10 8 = nc 7 =V 5 = nc 6 = nc = PE 3 =W Pin 1 2 3 4 5 6 7 8 PE 4 = nc 1 =U 2 = nc Conductor 1 – 3 – – – 2 – gr./yell. Assignment U – W – – – V – PE Technical data HQ8, male pin Silver Plastic Plastic 300/500 V 16 A IP 65 Lapp Ölflex Classic 110 4G2.5 or similar Length 3m 5m 10 m Qty. 1 piece 1 piece 1 piece * preferred types Order No. 8000011742* 8000011743 8000011744 Contact insert Contact surface Housing Cable gland Rated voltage U0/U Rated current Protection class (in plugged state) Line type Ordering data Type FPL 4G2.5C/Q8MW/3 FPL 4G2.5C/Q8MW/5 FPL 4G2.5C/Q8MW/10 HQ8, male pin Silver Plastic Plastic 300/500 V 16 A IP 65 Lapp Ölflex Classic 110 CY 4G2.5 or similar Length 3m 5m 10 m Qty. 1 piece 1 piece 1 piece * preferred types Dimensioned drawing Dimensioned drawing 3 m / 5 m / 10 m 9 Pin assignments 3 m / 5 m / 10 m Order No. 8000011748* 8000011749 8000011750 FPL motor lines FPL 7G2.5/Q8KW FPL 7G2.5C/Q8MW 7-conductor unshielded 7-conductor shielded Pin assignments 8 = nc 7 =V 5 = nc 6 = BR = PE 3 =W Pin 1 2 3 4 5 6 7 8 PE 4 = BR 1 =U 2 = nc Conductor 1 – 3 4 – 5 2 – gr./yell. Assignment U – W Brake – Brake V – PE Ordering data Type FPL 7G2.5/Q8KW/3 HQ8, male pin Silver Plastic Plastic 300/500 V 16 A IP 65 Lapp Ölflex Classic 110 7G2.5 or similar Length 3m Qty. 1 piece 7 =V 5 = nc 6 = BR = PE 3 =W Pin 1 2 3 4 5 6 7 8 PE 4 = BR 1 =U 2 = nc Conductor 1 – 3 4 – 5 2 – gr./yell. Order No. 8000011745* Contact insert Contact surface Housing Cable gland Rated voltage U0/U Rated current Protection class (in plugged state) Line type Assignment U – W Brake – Brake V – PE Ordering data Type FPL 7G2.5C/Q8MW/3 FPL 7G2.5C/Q8MW/5 FPL 7G2.5C/Q8MW/10 HQ8, male pin Silver Metal Metal 300/500 V 16 A IP 65 Lapp Ölflex Classic 110 CY 7G2.5 or similar Length 3m 5m 10 m Qty. 1 piece 1 piece 1 piece * preferred types * preferred types Dimensioned drawing Dimensioned drawing 3m 10 8 = nc Technical data Technical data Contact insert Contact surface Housing Cable gland Rated voltage U0/U Rated current Protection class (in plugged state) Line type Pin assignments 3 m / 5 m / 10 m Order No. 8000011751* 8000011752 8000011753 FieldPower® Drive FieldPower® Box 5-pole contact unit 3~, N, PE for power distribution with uncut round cable with 1.5 to 6-mm2 conductor crosssections. Power supply/T-branch via 0.5 to 10-mm2 PUSH IN connection and/or 0.5 to 4-mm2 plug-in connection. Coding on PE connection and marking for clear conductor assignment. FieldPower® Box FieldPower® Box 10P for AC applications for AC applications • Power supply • Power distribution • Power branching v AC labelling v 67 67 104 181 192 181 Technical data Rated data according to IEC 60947-7-1 Rated cross-section Rated voltage/Rated current Rated impulse voltage General data Insulation material/material colour UL 94 flammability class Free from halogens/Silicone-free Protection degree Assembly temperature range, min.-max. Operating temperature, min.-max. Can be coded IDC connection clamping capacity - power cable solid, min.-max. stranded, min.-max. flexible, min.-max. flexible, min.-max. Blade size PUSH IN connection clamping capacity - distribution solid, min.-max. stranded, min.-max. flexible, min.-max. flexible, wire end ferrule 8 mm, DIN 46228/1, min-max. flexible, wire end ferrule 8 mm, DIN 46228/4, min-max. flexible, wire end ferrule 12 mm, DIN 46228/1, min-max. flexible, wire end ferrule 12 mm, DIN 46228/4, min-max. flexible, min.-max. Stripping length/Blade size Rated data according to UL Standard Rated voltage/Rated current AWG conductor (field wiring) min./max. Note Note Ordering data Note 6 mm2 800 V/41 A 8 kV 6 mm2 800 V/41 A 8 kV Polycarbonate/black 5VA Yes/Yes IP 65 10 °C...40 °C -40 °C...55 °C Yes/Coded on PE Polycarbonate/black 5VA Yes/Yes IP 65 10 °C...40 °C -40 °C...55 °C Yes/Coded on PE 1.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 0.6 x 3.5 mm 1.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 0.6 x 3.5 mm 0.5 mm2…6 mm2 0.5 mm2…6 mm2 0.5 mm2…10 mm2 0.5 mm2…6 mm2 0.5 mm2…4 mm2 0.5 mm2…6 mm2 0.5 mm2…4 mm2 0.5 mm2…6 mm2 14 mm/0.6 x 3.5 mm 0.5 mm2…6 mm2 0.5 mm2…6 mm2 0.5 mm2…10 mm2 0.5 mm2…6 mm2 0.5 mm2…4 mm2 0.5 mm2…6 mm2 0.5 mm2…4 mm2 0.5 mm2…6 mm2 14 mm/0.6 x 3.5 mm UL 2237 600 V/30 A 14 /10 For use with UL-listed TC-ER cables UL 2237 600 V/30 A 14 /10 For use with UL-listed TC-ER cables Tip: Pipe Ölflex Classic 100, 110, 100 H or comparable Tip: Pipe Ölflex Classic 100, 110, 100 H or comparable Type FP Box Qty. 1 Order No. 1957580000 Type FP Box 10P Enclosure seals can be ordered separately. Enclosure seals can be ordered separately. Plug-in connector PTS 4 1952120000 Plug-in connector PTDS 4 1952130000 Plug-in connector PTS 4 1952120000 Plug-in connector PTDS 4 1952130000 Accessories Note 11 Qty. 1 Order No. 1957590000 FieldPower® Drive PowerTerminal 5-pole contact unit 3~, N, PE for power distribution with uncut round cable with 1.5 to 6-mm2 conductor crosssections. Power supply/T-branch via 0.5 to 10-mm2 PUSH IN connection and/or 0.5 to 4-mm2 plug-in connection. Coding on PE connection and marking for clear conductor assignment. PowerTerminal LG PowerTerminal GK for AC applications with a light grey cap for AC applications with transparent cap • Power supply • Power distribution • Power branching 60 74,9 74,9 15 7 60 15 7 AC labelling Technical data Rated data according to IEC 60947-7-1 Rated cross-section Rated voltage/Rated current Rated impulse voltage General data Insulation material/material colour UL 94 flammability class Free from halogens/Silicone-free Protection degree Assembly temperature range, min.-max. Operating temperature, min.-max. Can be coded IDC connection clamping capacity - power cable solid, min.-max. stranded, min.-max. flexible, min.-max. flexible, min.-max. Blade size PUSH IN connection clamping capacity - distribution solid, min.-max. stranded, min.-max. flexible, min.-max. flexible, wire end ferrule 8 mm, DIN 46228/1, min-max. flexible, wire end ferrule 8 mm, DIN 46228/4, min-max. flexible, wire end ferrule 12 mm, DIN 46228/1, min-max. flexible, wire end ferrule 12 mm, DIN 46228/4, min-max. flexible, min.-max. Stripping length/Blade size Rated data according to UL Standard Rated voltage/Rated current AWG conductor (field wiring) min./max. Note Note Ordering data Note 6 mm2 800 V/41 A 8 kV 6 mm2 800 V/41 A 8 kV Polycarbonate/grey V0 Yes/Yes IP 30 10 °C...40 °C -40 °C...55 °C Yes/Coded on PE Polycarbonate/grey V0 Yes/Yes IP 30 10 °C...40 °C -40 °C...55 °C Yes/Coded on PE 1.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 0.6 x 3.5 mm 1.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 0.6 x 3.5 mm 0.5 mm2…6 mm2 0.5 mm2…6 mm2 0.5 mm2…10 mm2 0.5 mm2…6 mm2 0.5 mm2…4 mm2 0.5 mm2…6 mm2 0.5 mm2…4 mm2 0.5 mm2…6 mm2 14 mm/0.6 x 3.5 mm 0.5 mm2…6 mm2 0.5 mm2…6 mm2 0.5 mm2…10 mm2 0.5 mm2…6 mm2 0.5 mm2…4 mm2 0.5 mm2…6 mm2 0.5 mm2…4 mm2 0.5 mm2…6 mm2 14 mm/0.6 x 3.5 mm Tip: Pipe Ölflex Classic 100, 110, 100 H or comparable Tip: Pipe Ölflex Classic 100, 110, 100 H or comparable Type PowerTerminal LG Qty. 1 Order No. 1963570000 Type PowerTerminal GK IP30 seals are included with delivery. IP30 seals are included with delivery. Plug-in connector PTS 4 1952120000 Plug-in connector PTDS 4 1952130000 Plug-in connector PTS 4 1952120000 Plug-in connector PTDS 4 1952130000 Accessories Note 12 Qty. 1 Order No. 1111910000 FieldPower® Drive FieldPower® Box Fuse 5-pole contact unit +1,-1, FE, -2, +2 with fuse plug-in connector. Max. power loss for G fuse terminals in accordance with IEC 60947-7-3: • Overload protection: 1.6 W (at 1.5 x IN) • Short-circuit protection: 4 W (at 1.5 x IN) Max. power loss per fuse at 23 °C Tu. FieldPower® Box Fuse FieldPower® Box Fuse R for AC applications, with local outage display With local outage display and no-voltage outage signal via M12 Do not exceed the max. power loss when selecting fuse cartridges. When a fuse is defective, the subsequent circuit is not voltage free. Pin 1 Pin 3 Pin 4 24 V ± 20 % Imax = 50 mA 0V Pin 2 86 104 181 3x 3x Technical data Rated data according to IEC 60947-7-3 Rated cross-section Rated voltage/Rated current Rated impulse voltage General data Insulation material/material colour UL 94 flammability class free from halogens/Silicone-free Protection degree Assembly temperature range, min.-max. Operating temperature, min.-max. Can be coded IDC connection clamping capacity - power cable solid, min.-max. stranded, min.-max. flexible, min.-max. flexible, min.-max. Blade size PUSH IN connection clamping capacity - distribution solid, min.-max. stranded, min.-max. flexible, min.-max. flexible, wire end ferrule 8 mm, DIN 46228/1, min-max. flexible, wire end ferrule 8 mm, DIN 46228/4, min-max. flexible, wire end ferrule 12 mm, DIN 46228/1, min-max. flexible, wire end ferrule 12 mm, DIN 46228/4, min-max. flexible, min.-max. Stripping length/Blade size General specifications – plug Clamping range, min.-max. Cartridge fuse Outage display Note Ordering data Note 6 mm2 690 V/12 A 8 kV 6 mm2 690 V/12 A 8 kV Polycarbonate/black 5VA Yes/Yes IP 65 10 °C...40 °C -40 °C...55 °C Yes/Coded on PE Polycarbonate/black 5VA Yes/Yes IP 65 10 °C...40 °C -40 °C...55 °C Yes/Coded on PE 1.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 0.6 x 3.5 mm 1.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 0.6 x 3.5 mm 0.5 mm2…6 mm2 0.5 mm2…6 mm2 0.5 mm2…10 mm2 0.5 mm2…6 mm2 0.5 mm2…4 mm2 0.5 mm2…6 mm2 0.5 mm2…4 mm2 0.5 mm2…6 mm2 14 mm/0.6 x 3.5 mm 0.5 mm2…6 mm2 0.5 mm2…6 mm2 0.5 mm2…10 mm2 0.5 mm2…6 mm2 0.5 mm2…4 mm2 0.5 mm2…6 mm2 0.5 mm2…4 mm2 0.5 mm2…6 mm2 14 mm/0.6 x 3.5 mm 0.5 mm2…4 mm2 6.3 x 32 mm (1/4 x 1 1/4") LED red 0.5 mm2…4 mm2 6.3 x 32 mm (1/4 x 1 1/4") LED red Accessories and practical tips are describe on page 51 Also with no-voltage outage signal via M12 connector. Type FP Box Fuse Qty. 1 Order No. 1961780000 Type FP Box Fuse R Qty. 1 Order No. 1025060000 Safety fuse not included in delivery. Enclosure seals can be ordered separately. Safety fuse not included in delivery. Enclosure seals can be ordered separately. Rated voltage and rated current with fuse are determined by the G-fuse cartridge in use. Rated voltage and rated current with fuse are determined by the G-fuse cartridge in use. Accessories Note 13 FieldPower® Drive FieldPower® Box On/Off FieldPower® Box On/Off Decentralised maintenance switch with on/off function and integrated power based on the FieldPower® Box. Connection to uncut power cable via a pre-assembled connector. Feedback signal for switch position via M12 connection. for AC applications, with ABB maintenance switch •Power switching •Power supply •Power distribution •Power branching v 1L1 3L2 5L3 13 PIN 4 165 M12: 2 3 4 10 181 2T1 4T2 6T3 14 PIN 1 4 Stifte Pins 1 Broches Pasadores Connettori maschio Technical data Rated data according to IEC 60947-7-1 Rated cross-section Rated voltage/Rated current Rated impulse voltage General data Insulation material/material colour UL 94 flammability class free from halogens/Silicone-free Protection degree Assembly temperature range, min.-max. Operating temperature, min.-max. Can be coded IDC connection clamping capacity - power cable solid, min.-max. stranded, min.-max. flexible, min.-max. flexible, min.-max. Blade size mm PUSH IN connection clamping capacity - distribution Clamping range, min.-max. Stripping length/Blade size Rated data according to UL Standard Rated voltage/Rated current AWG conductor (field wiring) min./max. Technical specifications – switch Standard 60947-3 Switch type/Auxiliary contact Pollution severity level Operating voltage Rated current AC-23A Power rating AC-23A Clamping capacity, min.-max. AWG conductor size, min.-max. Terminals - torque 6 mm2 800 V/41 A 8 kV Polycarbonate/black 5VA Yes/Yes IP 65 10 °C...40 °C -40 °C...45 °C Yes/Coded on PE 1.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 0.6 x 3.5 mm 0.75 mm2…10 mm2 14 mm/0.6 x 3.5 mm UL 508 600 V/16 A 14 /10 IEC 60947-3 ABB OT16ET3/ABB OA1G10 3 440 V 16 A 7.5 kW 0.75 mm2…10 mm2 AWG 18…AWG 8 0.8 Nm Note Ordering data Type FP Box On/Off Qty. 1 Order No. 1003260000 Enclosure seals can be ordered separately. Accessories Note 14 Lockable with up to three security locks to protect against accidental power-up. FieldPower® Drive FieldPower® Box Fuse DC 5-pole contact unit +1,-1, FE, -2, +2 with fuse plug-in connector. Max. power loss for G fuse terminals in accordance with IEC 60947-7-3: • Overload protection: 1.6 W (at 1.5 x IN) • Short-circuit protection: 4 W (at 1.5 x IN) Max. power loss per fuse at 23 °C Tu. FieldPower® Box Fuse DC Do not exceed the max. power loss when selecting fuse cartridges. When a fuse is defective, the subsequent circuit is not voltage free. A practical tip: Space for spare fuses 86 104 181 2x Technical data Rated data according to IEC 60947-7-3 Rated cross-section Rated voltage/Rated current Rated impulse voltage General data Insulation material/material colour UL 94 flammability class free from halogens/Silicone-free Protection degree Assembly temperature range, min.-max. Operating temperature, min.-max. Can be coded IDC connection clamping capacity - power cable solid, min.-max. stranded, min.-max. flexible, min.-max. flexible, min.-max. Blade size PUSH IN connection clamping capacity - distribution solid, min.-max. stranded, min.-max. flexible, min.-max. flexible, wire end ferrule 8 mm, DIN 46228/1, min-max. flexible, wire end ferrule 8 mm, DIN 46228/4, min-max. flexible, wire end ferrule 12 mm, DIN 46228/1, min-max. flexible, wire end ferrule 12 mm, DIN 46228/4, min-max. flexible, min.-max. Stripping length/Blade size General specifications – plug Clamping range, min.-max. Cartridge fuse Outage display 6 mm2 36 V/12 A 8 kV Polycarbonate/black 5 VA Yes/Yes IP 65 10 °C...40 °C -40 °C...55 °C Yes/Coded on PE Protection degree IP 20 IP 65 1.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 0.6 x 3.5 mm Only short-circuit Overload and protection short-circuit protection TA max. Nominal values TA max. Nominal values 46 °C 4.0 W / 10 A 28 °C 2.5 W / 2.5 A 23 °C 4.0 W / 10 A 39 °C 1.6 W / 1.0 A Fuses and power loss: Examples 0.5 mm2…6 mm2 0.5 mm2…6 mm2 0.5 mm2…10 mm2 0.5 mm2…6 mm2 0.5 mm2…4 mm2 0.5 mm2…6 mm2 0.5 mm2…4 mm2 0.5 mm2…6 mm2 14 mm/0.6 x 3.5 mm Current 1.0 A 1.6 A 2.0 A 4 A 6.3 A 8 A 10 A 12.5 A SIBA, 1.0 x IN 0.35 W 0.32 W 0.36 W 0.56 W 0.69 W 0.88 W 1 W 1.25 W 189140 500 V, 440 V, 1.5 x IN 0.9 W 1.1 W 1.2 W 1.5 W 2.2 W 2.6 W 3.0 W 3.5 W 250 V T SIBA, 1.0 x IN – – – – 1.2 W 1.5 W 1.8 W 1.9 W 7006584 400 V 1.25 x IN – – – – 2.5 W 3.2 W 3.7 W 3.9 W gRL No responsibility is taken for the correctness of this information. Further details can be obtained from the fuse manufacturers. 0.5 mm2…4 mm2 6.3 x 32 mm (1/4 x 1 1/4") LED red Derating curve for IP65 use: Ordering data Note Type FP Box Fuse DC Qty. 1 Order No. 8000007924 Safety fuse not included in delivery. Enclosure seals can be ordered separately. Accessories Note 15 Rated voltage and rated current with fuse are determined by the G-fuse cartridge in use. 4.5 4 3.5 3 2.5 2 1.5 1 0.5 0 Power loss P [W] bei I = 1.5 x IN Note 0 10 20 30 40 50 60 70 80 Ambient temperature T [°C] Only short-circuit protection Overload and short-circuit protection 90 100 110 120 FieldPower® Drive FieldPower® Box 10P 4XVG Contact element for power distribution using uncut wires with cross-sections from 1.5 to 6 mm². Feed-in / T-branch tap via PUSH IN connection (0.5 to 10 mm²) and/or plug-in connection (0.5 to 4 mm²). Clear and precise wire assignments: with coding on the PE connection. FieldPower® Box 10P 4XVG for AC and DC-applications • Power supply • Power distribution • Power branching Included in delivery: 4 cable glands M20 (Clamping range 6 – 12mm) fitted in bottom housing 67 192 181 Plug-in connector PTDS 4 Technical data Rated data according to IEC 60947-7-1 Rated cross-section Rated voltage / Rated current Rated impulse voltage General data Insulation material/material colour UL 94 flammability rating free from halogens/Silicone-free Ingress protection class Assembly temperature range, min. – max. Operating temperature, min.-max. Can be coded IDC connection clamping capacity - power cable solid, min.-max. stranded, min.-max. flexible, min.-max. flexible, min.-max. Blade size PUSH IN connection clamping capacity - distribution solid, min.-max. stranded, min.-max. flexible, min.-max. flexible, wire end ferrule 8 mm, DIN 46228/1, min-max. flexible, wire end ferrule 8 mm, DIN 46228/4, min-max. flexible, wire end ferrule 12 mm, DIN 46228/1, min-max. flexible, wire end ferrule 12 mm, DIN 46228/4, min-max. flexible, min.-max. Stripping length/Blade size For AC applications: 6 mm2 800 V/41 A 8 kV Polycarbonate/black 5VA Yes/Yes IP 65 10 °C...40 °C -40 °C...55 °C Yes/Coded on PE PowerTerminal PT6 1.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 2.5 mm2…6 mm2 0.6 x 3.5 mm For DC applications: 0.5 mm2…6 mm2 0.5 mm2…6 mm2 0.5 mm2…10 mm2 0.5 mm2…6 mm2 0.5 mm2…4 mm2 0.5 mm2…6 mm2 0.5 mm2…4 mm2 0.5 mm2…6 mm2 14 mm/0.6 x 3.5 mm Plug-in connector PTDS 4 DC PowerTerminal PT6 DC Note Ordering data Note Accessories Note 16 Tip: Pipe Ölflex Classic 100, 110, 100 H or comparable Type FP Box 10P 4XVG Qty. 1 Order No. 1002900000 Seals: 2x RKDG D11 PT6 (9-11mm) 4x RKDG D13 PT6 (11-13mm) 4x RKDG D15 PT6 (13-15mm) 1x DG D0 PT6 (Blanking seal) Accessories Seals for FieldPower® Box Seal for round cable Blanking seal IP65 enclosure seals for the FieldPower Box modules: made from silicone-free, halogen-free material. The seals are slit in the middle to allow for simple installation with uncut power cables. ® ø Technical data General data Material UL 94 flammability class Colour Thickness Line type Free from halogens Silicone-free Ingress protection class EPDM HB black 18 mm round Yes Yes IP 65 EPDM HB black 18 mm Yes Yes IP 65 Note Ordering data Clamping range Ø 7.5 - 9 mm 9 - 11 mm 11 - 13 mm 13 - 15 mm 15 - 17 mm Note Accessories Note 17 Type RKDG D9 PT6 RKDG D11 PT6 RKDG D13 PT6 RKDG D15 PT6 RKDG D17 PT6 Qty. 10 10 10 10 10 Order No. 4329610000 4323210000 4323230000 4323220000 4324010000 Type DG D0 PT6 Qty. 10 Order No. 4323240000 FieldPower® Control Plug-in connectors for AC applications Plug-in connectors for use by the pluggable output of the contact elements. Individual wires can be connected with PUSH IN method: for cross-sections from 0.5 to 4 mm². Can be coded and locked, with printing for trouble-free wiring. Clear wire mapping with coding for PE connections.. PTS 4 PTDS 4 2 connections per pole { 27,3 55,45 36,15 36,15 22 27,3 22 55,45 { Technical data Rated data according to IEC 60947-7-1 Rated cross-section Rated voltage/Rated current Rated impulse voltage General data Type of mounting Insulation material/material colour UL 94 flammability class Continuous operating temp., min.-max. Outgoing direction of conductor Test point Can be coded Conductor connection system No. of poles Number of connections / pole Clamping capacity, PUSH IN connection Clamping range, min.-max. solid, min.-max. stranded, min.-max. flexible, min.-max. flexible, wire end ferrule 8 mm, DIN 46228/1, min.-max. flexible, wire end ferrule 8 mm, DIN 46228/4, min.-max. flexible, wire end ferrule 12 mm, DIN 46228/1, min.-max. flexible, wire end ferrule 12 mm, DIN 46228/4, min.-max. flexible, min.-max. Stripping length/Blade size Rated data according to UL Standard Rated voltage/Rated current AWG conductor (field wiring) min./max. 4 mm² 690 V / 32 A 8 kV 4 mm² 690 V / 32 A 8 kV Plugged PA GF/ black V0 -50 °C...120 °C 90° 2 mm Yes/Coded on PE PUSH IN 5 1 Plugged PA GF/ black V0 -50 °C...120 °C 90° 2 mm Yes/Coded on PE PUSH IN 5 2 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 12 mm / 3.0 x 0.5 mm 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 0.5 mm²…4 mm² 12 mm / 3.0 x 0.5 mm UL 1059 600 V/20 A 16 /12 UL 1059 600 V/20 A 16 /12 Note Ordering data Type PTS 4 Qty. 10 Order No. 1952120000 Type PTDS 4 Qty. 10 Note Accessories Note 18 ZVR ZP2.5 locking element 1816130000 ZVR ZP2.5 locking element 1816130000 Order No. 1952130000 Tools Sheathing stripper • Sheathing stripper for PVC cables Technical data Max. stripping performance Cable model Conductor cross-section Conductor diameter Max. stripping length Adjustable depth of cut Cutting performance Max. cutting performance mm2 mm mm mm AM 16 AM 25 • Sheathing stripper for round PVC cables • Insulation can be stripped from any point along the cable • Especially suitable for stripping cables in the cable duct, too. • Hinged knife for circumferential and longitudial cuts • Handle tips with integrated cutter for opening slit insulation • Pivoting blade for circumferential, lengthwise and spiral cuts • Retaining clip with integrated blade to break open an incision in the insulation • Integrated spare blade AM 16 PVC round cable AM 25 PVC round cable 6…17.3 6…25 0.8 - 2.5 mm up to 4.5 mm 53 60 135 135 mm2 Tool data Lengthmm Weightg Note Ordering data Version Type AM 16 Qty. 1 Order No. 9204190000 Type AM 25 Qty. 1 Order No. 9001540000 Type Spare blade Qty. 1 Order No. 9204260000 Type Spare blade Qty. 2 Order No. 9001530000 Note Accessories Note 19 Sheathing stripper Sheathing stripper Tools KT 20 SD S / SDK PZ2 Cutter Screwdriver Cutting tool that does not damage the conductor; for cutting copper and aluminium cables with a diameter of up to 20 mm. • Not suitable for steel wires, steel-armoured cables, aluminium alloys and hard-drawn copper conductors! • Easy handling because of automatic opening • Safety lock reduces risk of injury Technical data Max. cutting performance copper cable Solid (max. conductor cross-section) mm2 / AWG Stranded (max. conductor cross-section) mm2 / AWG Flexible (max. conductor cross-section) mm2 / AWG Flexible, Stranded (max. diameter) mm Sector line Max. cutting performance aluminium cable stranded (conductor cross-section max.) mm2 / AWG Stranded (max. diameter) mm solidmm2 Data-/ telephone-/ control cable O.D. max. mm Tool data Length / width / height mm Weightg KT20 16 / 6 35 / 2 70 / 2/0 20 Note Tool closed Ordering data 20 215 / 66 / 29 400 Version Type KT 20 Note Specifying solid-core aluminium cable corresponds to sector-shaped conductor with individual strands Accessories Note 20 70 / 2/0 20 35 Type Qty. 1 Qty. Order No. 9002300000 Order No. Type SDK PZ2 SD 0,5 x 3,0 x 80 SD 0,6 x 3,5 x 100 Qty. 1 1 1 Order No. 9008540000 9008320000 9008330000 Type Qty. Order No. Drilling templates Drilling templates 29.9 69.2 PT6 108.5 139.5 89 89 104 FieldPower® Box 165 181 21 Drilling templates 192 177 192 FieldPower® Box 10P 165 181 22 Weidmüller – Your partner in Industrial Connectivity As experienced experts we support our customers and partners around the world with products, solutions and services in the industrial environment of power, signal and data. We are at home in their industries and markets and know the technological challenges of tomorrow. We are therefore continuously developing innovative, sustainable and useful solutions for their individual needs. Together we set standards in Industrial Connectivity. Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 32758 Detmold, Germany T +49 5231 14-0 F +49 5231 14-292083 info@weidmueller.com www.weidmueller.com Your local Weidmüller partner can be found on our website: www.weidmueller.com/countries Order number: 1437900000/04/2013/SMDM