2015 PACKAGE TERMINAL AIR CONDITIONERS Q U I E T, R E L I A B L E R O O M C O M F O RT QUIET OPERATION A number of elements such universal heater, tangential fan, and separate indoor and outdoor fans ensure Haier PTACs are exceptionally quiet. The chassis is well-sealed to help prevent the transmission of outdoor noise. In addition, vibration-reducing rubber mounts for the compressor and a well-insulated sleeve add to the unit’s noise reduction package. UNIVERSAL CHASSIS The 16” x 42” size fits all competitor 42” sleeves. The power cord, length determined by the model’s BTU, is included. Additional power cords are available depending on the kW Heater requirements. All this makes Haier PTACs the clear choice for replacing an existing unit. FRONT PANEL A stylish, multi-position front. The angled discharge area allows for uniform air distribution throughout the room. Access to the digital control module and the washable filters is located on the top. ACC E S S O R I E S Description Part PTAC Power Cord 230V 15A HAPCRD001 PTAC Power Cord 230V 20A HAPCRD002 PTAC Power Cord 230V 30A HAPCRD003 Drain Kit HADRAN01 Universal Sub Base HASUBB01 Stamped Aluminum Rear Grille HASAGL01 Architectural Aluminum Real Grill HAAGL01 Wall Sleeve HAWSLV01 DIGITAL CONTROL MODULE The large, easy to read control module is conveniently accessible on the unit. You also have the option of removing it from the unit and using it as a wired wall-mounted control thermostat, allowing for more accurate room temperature measurement. SLEEVE AND REAR GRILLE These accessories are sold separately. Aluminum and Architectural Grilles are also available. FEATURES PRODUCT DIMENSIONS Central Desk Control Compatible 42”(W) x 16”(H) x 21(D) Temperature Set Point Limit Fan Speed Selection Field Commissioning Function WALL CUT OUT 42 1/2” (W) x 16 1/4” (H) Random Restart Compressor Restart Delay (i) This escutcheon cover should be ordered whenever the display module is wall mounted or third party provider unit controls are ordered. This escutcheon includes a control cover plate that covers the normal unit mounted nomenclature. It comes 5 pieces per pack. (ii) Require when using a Hard Wire Kit. (iii) Provides a space to tie into a building’s wiring with a receptacle to plug the unit into. It gives additional leveling and support capabilities and provides a place for fuses, a circuit breaker or a mechanical disconnect to be mounted. (30A is for unit with 5kW electric heat, 15A and 20A for 3kW Heat). (iv) 15, 20 and 30 AMP subbases require a socket. F E AT U R E S UNIVERSAL HEATER ROOM FREEZE PROTECTION The universal heater is capable of handling 2kW, 3kW or 5kW applications. A 20 amp power cord comes standard with the 7000, 9000, and 12000 BTU units. The 15000 BTU units come with a 30 amp power cord. Monitors the temperature and switches on the electric heat to ensure that the room temperature will not drop below 40°F. EASY-ACCESS FILTERS VENT DOOR Two nylon mesh, washable filters are included to keep the unit operating efficiently. Front panel access allows them to be easily removed for cleaning. The large vent door can be opened to allow 70 or 80 CFM (depending on model) of fresh air to enter the room when the indoor fan is operating. TANGENTIAL FAN WARRANTY The balanced tangential fan provides symmetrical and stable airflow for quieter operation and enhanced guest comfort. 1st year parts and labor, 2nd through 5th year on the sealed system, limited 2nd through 5th year functional parts only. BUILT-IN SELF DIAGNOSTICS The digital interface module is capable of performing and displaying self-diagnostics on key functions. Features and specifications are subject to change Haier America, Wayne, NJ 07470 For more information: www.Haier.com 1.877.337.3639 CO O L I N G MODELS Model Number Cooling Capacity BTU/Hr. PERFORMANCE ELECTRICAL INDOOR CFM DIMENSIONS/ WEIGHT PTCH0701UAC 230V 208V 230V 208V 230V 7200 7400 8600 8800 11800 12000 13800 14000 11.9 11.2 10.6 2.1 2.6 3.1 4.1 Indoor dbA 45/44 45/44 51/50 53/52 H E AT P U M P MODELS DIMENSIONS/ WEIGHT Outdoor dbA 58 59 66 66 197/253 197/253 197/253 197/253 Amps (1) 2.7 2.9 3.6 3.9 4.8 5.1 6.4 6.9 High Speed 260 290 260 290 320 350 365 400 Low Speed 235 266 235 266 293 323 330 U N I V E RSA L E L EC T R I C H E AT E R S P EC I F I C AT I O N S ELECTRICAL NOTES 360 Ventillation 70 70 80 80 Height/Width/Depth 16”x42”x21” 16”x42”x21” 16”x42”x21” 16”x42”x21” Net/Shipping Lbs 96/109 97/111 100/123 119/132 PTHH0701UAC Heating Capacity BTU/Hr. PTHH0901UAD PTHH1201UAC PTHH1501UAC 208V 230V 230V 230V 208V 230V 208V 230V 7000 7200 8700 8900 11800 12000 13300 13600 6700 7800 8000 10600 10800 12500 11.9 6500 COP 11.4 3.5 10.6 3.3 10.9 13000 3.2 3.1 Dehumidification Pts/Hr. 2.1 2.6 3.1 4.1 Indoor dbA 46/45 47/46 53/52 53/52 Outdoor dbA 58 58 66 66 Voltage Range Min/Max 197/253 197/253 197/253 197/253 Amps (1) 2.9 2.7 3.8 3.6 5.3 4.9 6.8 6.2 High Speed 260 290 260 290 320 350 365 400 Low Speed 235 266 235 266 293 323 330 360 Ventillation 70 70 80 80 Height/Width/Depth 16”x42”x21” 16”x42”x21” 16”x42”x21” 16”x42”x21” Net/Shipping Lbs 99/113 104/117 115/128 124/138 2kW Heater Electric Heater PERFORMANCE 9.8 Voltage Range Min/Max EER INDOOR CFM PTCH 1501UAC 230V EER Cooling Capacity BTU/Hr. ELECTRICAL PTCH1201UAC 230V Dehumidification Pts/Hr. Model Number PERFORMANCE PTCH0901UAC 208V Heating BTU/Hr. 3kW Heater 5kW Heater 208V 230V 230V 230V 208V 230V 5500 6800 8200 10200 13700 17100 Heating Amps 7.9 8.9 11.8 13.4 19.7 22.2 Heating Watts 1600 2000 2400 3000 4000 5000 Min. Circuit Ampacity 11.4 17 28 Circuit Breaker Size 15 20 30 P OW E R R EC E P TAC L E CO N F I G U R AT I O N S NEMA Receptacle Type 6-15R 6-20R 6-30R Power Cord Kit Required HAPCRD01 HAPCRD02 HAPCRD03 230/208 230/208 230/208 6-30R (1) - Use Electric Heat data for Maximum amp draw (2) - 5kW heater is not available on 7000 BTU models. Unit Voltage Rating PERFORMANCE Receptacle NEMA Configuration 6-15R 6-20R ELECTRICAL Receptacle Amp Rating 15 20 30 Power Cord Kit Required HAPCRD01 HAPCRD02 HAPCRD03 NOTES The 7000, 9000, and 12000 BTU models come with a 20 amp cord for 3kW of heat. The 15000 BTU models come with a 30 amp power cord for 5kW of heat.