PTACs

advertisement
2015
PACKAGE TERMINAL
AIR CONDITIONERS
Q U I E T, R E L I A B L E R O O M C O M F O RT
QUIET OPERATION
A number of elements such universal heater, tangential fan, and separate
indoor and outdoor fans ensure Haier PTACs are exceptionally quiet. The
chassis is well-sealed to help prevent the transmission of outdoor noise.
In addition, vibration-reducing rubber mounts for the compressor and a
well-insulated sleeve add to the unit’s noise reduction package.
UNIVERSAL CHASSIS
The 16” x 42” size fits all competitor 42” sleeves. The power cord, length
determined by the model’s BTU, is included. Additional power cords are
available depending on the kW Heater requirements. All this makes Haier
PTACs the clear choice for replacing an existing unit.
FRONT PANEL
A stylish, multi-position front. The angled discharge area allows for
uniform air distribution throughout the room. Access to the digital control
module and the washable filters is located on the top.
ACC E S S O R I E S
Description
Part
PTAC Power Cord 230V 15A
HAPCRD001
PTAC Power Cord 230V 20A
HAPCRD002
PTAC Power Cord 230V 30A
HAPCRD003
Drain Kit
HADRAN01
Universal Sub Base
HASUBB01
Stamped Aluminum
Rear Grille
HASAGL01
Architectural Aluminum
Real Grill
HAAGL01
Wall Sleeve
HAWSLV01
DIGITAL CONTROL MODULE
The large, easy to read control module is conveniently accessible on the
unit. You also have the option of removing it from the unit and using it
as a wired wall-mounted control thermostat, allowing for more accurate
room temperature measurement.
SLEEVE AND REAR GRILLE
These accessories are sold separately. Aluminum and Architectural
Grilles are also available.
FEATURES
PRODUCT DIMENSIONS
Central Desk Control Compatible
42”(W) x 16”(H) x 21(D)
Temperature Set Point Limit
Fan Speed Selection
Field Commissioning Function
WALL CUT OUT
42 1/2” (W) x 16 1/4” (H)
Random Restart
Compressor Restart Delay
(i) This escutcheon cover should be ordered whenever the display
module is wall mounted or third party provider unit controls are
ordered. This escutcheon includes a control cover plate that covers
the normal unit mounted nomenclature. It comes 5 pieces per pack.
(ii) Require when using a Hard Wire Kit.
(iii) Provides a space to tie into a building’s wiring with a receptacle to plug the
unit into. It gives additional leveling and support capabilities and provides a
place for fuses, a circuit breaker or a mechanical disconnect to be mounted.
(30A is for unit with 5kW electric heat, 15A and 20A for 3kW Heat).
(iv) 15, 20 and 30 AMP subbases require a socket.
F E AT U R E S
UNIVERSAL HEATER
ROOM FREEZE PROTECTION
The universal heater is capable of handling
2kW, 3kW or 5kW applications. A 20 amp
power cord comes standard with the 7000,
9000, and 12000 BTU units. The 15000
BTU units come with a 30 amp power cord.
Monitors the temperature and switches on
the electric heat to ensure that the room
temperature will not drop below 40°F.
EASY-ACCESS FILTERS
VENT DOOR
Two nylon mesh, washable filters are
included to keep the unit operating
efficiently. Front panel access allows them
to be easily removed for cleaning.
The large vent door can be opened to
allow 70 or 80 CFM (depending on model)
of fresh air to enter the room when the
indoor fan is operating.
TANGENTIAL FAN
WARRANTY
The balanced tangential fan provides
symmetrical and stable airflow for quieter
operation and enhanced guest comfort.
1st year parts and labor, 2nd through 5th
year on the sealed system, limited 2nd
through 5th year functional parts only.
BUILT-IN SELF DIAGNOSTICS
The digital interface module is capable of
performing and displaying self-diagnostics
on key functions.
Features and specifications are subject to change
Haier America, Wayne, NJ 07470
For more information: www.Haier.com
1.877.337.3639
CO O L I N G
MODELS
Model Number
Cooling Capacity BTU/Hr.
PERFORMANCE
ELECTRICAL
INDOOR CFM
DIMENSIONS/
WEIGHT
PTCH0701UAC
230V
208V
230V
208V
230V
7200
7400
8600
8800
11800
12000
13800
14000
11.9
11.2
10.6
2.1
2.6
3.1
4.1
Indoor dbA
45/44
45/44
51/50
53/52
H E AT P U M P
MODELS
DIMENSIONS/
WEIGHT
Outdoor dbA
58
59
66
66
197/253
197/253
197/253
197/253
Amps (1)
2.7
2.9
3.6
3.9
4.8
5.1
6.4
6.9
High Speed
260
290
260
290
320
350
365
400
Low Speed
235
266
235
266
293
323
330
U N I V E RSA L
E L EC T R I C H E AT E R
S P EC I F I C AT I O N S
ELECTRICAL
NOTES
360
Ventillation
70
70
80
80
Height/Width/Depth
16”x42”x21”
16”x42”x21”
16”x42”x21”
16”x42”x21”
Net/Shipping Lbs
96/109
97/111
100/123
119/132
PTHH0701UAC
Heating Capacity BTU/Hr.
PTHH0901UAD
PTHH1201UAC
PTHH1501UAC
208V
230V
230V
230V
208V
230V
208V
230V
7000
7200
8700
8900
11800
12000
13300
13600
6700
7800
8000
10600
10800
12500
11.9
6500
COP
11.4
3.5
10.6
3.3
10.9
13000
3.2
3.1
Dehumidification Pts/Hr.
2.1
2.6
3.1
4.1
Indoor dbA
46/45
47/46
53/52
53/52
Outdoor dbA
58
58
66
66
Voltage Range Min/Max
197/253
197/253
197/253
197/253
Amps (1)
2.9
2.7
3.8
3.6
5.3
4.9
6.8
6.2
High Speed
260
290
260
290
320
350
365
400
Low Speed
235
266
235
266
293
323
330
360
Ventillation
70
70
80
80
Height/Width/Depth
16”x42”x21”
16”x42”x21”
16”x42”x21”
16”x42”x21”
Net/Shipping Lbs
99/113
104/117
115/128
124/138
2kW Heater
Electric Heater
PERFORMANCE
9.8
Voltage Range Min/Max
EER
INDOOR CFM
PTCH 1501UAC
230V
EER
Cooling Capacity BTU/Hr.
ELECTRICAL
PTCH1201UAC
230V
Dehumidification Pts/Hr.
Model Number
PERFORMANCE
PTCH0901UAC
208V
Heating BTU/Hr.
3kW Heater
5kW Heater
208V
230V
230V
230V
208V
230V
5500
6800
8200
10200
13700
17100
Heating Amps
7.9
8.9
11.8
13.4
19.7
22.2
Heating Watts
1600
2000
2400
3000
4000
5000
Min. Circuit Ampacity
11.4
17
28
Circuit Breaker Size
15
20
30
P OW E R
R EC E P TAC L E
CO N F I G U R AT I O N S
NEMA Receptacle Type
6-15R
6-20R
6-30R
Power Cord Kit Required
HAPCRD01
HAPCRD02
HAPCRD03
230/208
230/208
230/208
6-30R
(1) - Use Electric Heat data for Maximum amp draw
(2) - 5kW heater is not available on 7000 BTU models.
Unit Voltage Rating
PERFORMANCE
Receptacle
NEMA Configuration
6-15R
6-20R
ELECTRICAL
Receptacle Amp Rating
15
20
30
Power Cord Kit Required
HAPCRD01
HAPCRD02
HAPCRD03
NOTES
The 7000, 9000, and 12000 BTU models come with a 20 amp cord for 3kW of heat.
The 15000 BTU models come with a 30 amp power cord for 5kW of heat.
Download