ADAGIO™-MN / ADAGIO-MP / ADAGIO-EN

advertisement
ADAGIO™-MN / ADAGIO-MP / ADAGIO-EN
Appliance Specifications - Adagio Series Direct Vent Fireplace Heaters
TM
1/2” (13mm) 1-1/2” (38mm)
Facade (Required) *
(arched style
shown)
Facade
Fireplace Dimensions - Inches (millimeters)
Co-axial DV Vent
4-1/2" (114) Inner
7-1/2" (191) Outer
Arch Facades*
Black & Brushed
Nickel Finishes
15-1/32
(382)
Fireplace Dimensions
15-15/32
(393)
20-1/4”
(514)
38-1/2”
(978)
7-11/16
(195)
1/2”
(13)
14-13/16” (376)
26-3/4” (680)
Facade (Required) *
Gated Facades (gated style
shown)
Facade
Copper and Iron Gates
40-1/32
(1017)
20-3/4
(527)
34
(864)
5-13/32
(137)
1/2” (13mm) 1-1/2” (38mm)
36-23/32
(933)
20-3/4”
(527)
37-7/8”
(962)
1-7/8
(48)
6-1/16
(154)
14-3/4 (375)
21-1/16 (535)
1-1/2
(38)
8-7/32
(209)
18-3/4
(476)
14-3/4”
(375)
23-1/2” (597)
1/2”
(13)
Facades
Notes
Cat. #
Model
Due to Lennox' ongoing commitment to quality, all specifications, ratings and
dimensions are subject to change without notice.
H5773
ADAGIO-AG
Arch Black
H5774
ADAGIO-PF
Arch Br. Nickel
H5775
ADAGIO-IG
Iron Gates
H5776
ADAGIO-CPD
Copper Gates
** With the facade installed (required - sold separately), the appliance base
will need to be elevated a minimum of 3/4" above the floor to allow for the
proper fit of the facade (i.e. use 3/4" board minimum as platform).
Corner Framing Dimensions - All Models
Framing Dimensions
* A filigree inset kit is
also required (sold
separately). See Care
and Operation Manual
for ordering information.
Framing Dimensions - All Models
A
B
C
D
E
in.
22-1/8
41-5/8
29-1/2
10
20-7/8
mm
562
1057
749
254
530
A
B
C
D
in.
22-1/8
40-1/4
15-3/4
44-1/8
mm
562
1022
400
1121
VENT FRAMING TOP VENT WITH ONE
90° ELBOW
Top Vent With Horizontal Termination In A Corner
Corner Framing With
SV4.5HT-2 Termination
D
7 (178)
�
C
Description
10-1/2
(267)
2 x 4 Header must be
installed, vertical as shown
to allow proper clearance
from venting components to
combustible header. See
Figure 50 for more
details.
Inches (mm)
8
5-1/8
(130)
E
(203)
13-1/8
(333)
D*
B
A
Platform
**
B
C
Inches
Back wall of chase/enclosure
When
in a corner configuration,
(millimeters)one of
(including
any installing
finishing materials)
u
the rear stand-offs will need to be removed.
P/N 775,617M, REV. A, 06/2008
Framing should be
constructed of 2x4
or larger lumber
A
3/4” Minimum from
Finished Floor
Page 1 of 2
Listing Information
ADAGIO™-MN / ADAGIO-MP / ADAGIO-EN
Input (BTU) - Millivolt Models
Do not insulate the
space between the
appliance and the
area above it.
Natural (NG) & Propane (LP) Gas
Models
Fuel
Input Rate (BTU / HR)
Adagio-MN
NG
13,000 (10,000 Low)
Adagio-MP
LP
13,000 (10,000 Low)
Input (BTU) - Electronic Models
Shelf Height
4” �
(102mm)
Drywall
u 4" clearance is
Natural (NG) & Propane (LP) Gas
Models
Fuel
Input Rate (BTU / HR)
Adagio-EN
NG
13,000 (10,000 Low)
Adagio-EP
LP
13,000 (10,000 Low)
US
Models
*Shelf Height
(see table)
Report No. 116-F-48-5
if field converted
Secure Vent
Secure Flex (flex elbow)
*52 (1321)
*53-3/4 (1365)
* Includes 4” clearance to combustibles (required above vent components)
1/2 (13) - 0 (0) Spacers**
Top Spacers
0 (0)
Vent
12 (305) Mantel
Combustible Materials Allowed
In Shaded Area “Safe Zone”
8 (203) Mantel
0 (0)***
64 (1626)
10 (254) Mantel
12" (305)
17"
(432)
inches (millimeters)
3 (76) Top * - 1 (25.4)
Sides & Bottom
3 ft. (0.9 m)
16
(406)
5"
Top View Of
(127) Fireplace
45 °
Service Clearances -Feet (meters)
Front
Mantel Clearances
Inches (mm)
2” (51) Minimum
Clearance to Combustibles
1/2 (13) - 0 (0) Spacers
Sides
Bottom of Appliance
To Ceiling
Shelf Above Fireplace - Top Vent
Side Wall Clearances (top view)
Inches (millimeters)
Floor
Top Spacers
Top Vent - with One 90 Degree Elbow
Adagio-MN
Adagio-MP
Adagio-EN
Back
required above the
elbow for installations
that require an elbow at
the top of the unit and
that ends in a horizontal
termination.
Combustible Shelf Height - Inches (millimeters)
Minimum Clearances
Clearances
Header
Tested to ANSI Z21.88 (in
Canada, CSA-2.33), and
CAN/CGA-2.17-M91 in both
USA and Canada, as vented
gas fireplace heaters.
6 (152) Mantel
14
(356)
12
(305)
4 (102) Mantel
10
(254)
Min. Distance
8-1/4” (210) to
Protected Side Wall
Side
Wall
8
(203)
2 (51) Mantel
Top Of
Appliance
6
(152)
Side
Wall
Min. Distance to
Unprotected Side Wall
14" (356)
Venting Requirements
* Note: 3 in. (75 mm) above any horizontal vent component, except for installations which have and elbow connected to fireplace collar and that ends
in a horizontal termination (this installation requires a 4” clearance above vent).
** Note: See Installation Instructions Manual on Page 6 (Step 1) for clearance requirements to the nailing flange located at each side of the unit and
any screw heads adjacent to it.
***Note: To ensure proper fit of the facade, the appliance base will need to be elevated 3/4" above the floor to allow for the proper fit of the facade (i.e.
Use 3/4" board as platform).
Vertical
Termination Cap
SV4.5CGV-1
(rated for high
winds and freezing conditions)
Square Horizontal Termination (SV4.5HT-2)
12-1/8”
(308 mm)
Ceiling Framing
10-1/2 in.
(267 mm)
P/N 775,617M REV. A 06/2008
10-1/2”
(267mm)
3"
(76 mm)
Adapter SV4.5RCH
1"
(25.4 mm)
10-1/2 in.
(267 mm)
Printed in U.S.A. © 2007 Lennox Hearth Products
Firestop / spacer (SV4.5HF) shown on the exterior side
of the wall. It may also be installed on the interior side.
5-1/8”
(130 mm)
* Ceiling Firestop/
Spacer (SV4.5VF)
Typical
Installation
7"
(178)
6 to 48 inch Vent
Section, Telescopic
vent section, Elbow or
Appliance Collar
Note: Center line of
Vent Piping is NOT
the Same as the
Center line of the
Framed Opening.
See Page 1 for Min.
Distance to Base of Appliance.
Specifications and clearances are subject to change without notice.
Refer to Installation Manual before installation of these appliances for
updated dimensions and instructions.
Page 2 of 2