ADAGIO™-MN / ADAGIO-MP / ADAGIO-EN Appliance Specifications - Adagio Series Direct Vent Fireplace Heaters TM 1/2” (13mm) 1-1/2” (38mm) Facade (Required) * (arched style shown) Facade Fireplace Dimensions - Inches (millimeters) Co-axial DV Vent 4-1/2" (114) Inner 7-1/2" (191) Outer Arch Facades* Black & Brushed Nickel Finishes 15-1/32 (382) Fireplace Dimensions 15-15/32 (393) 20-1/4” (514) 38-1/2” (978) 7-11/16 (195) 1/2” (13) 14-13/16” (376) 26-3/4” (680) Facade (Required) * Gated Facades (gated style shown) Facade Copper and Iron Gates 40-1/32 (1017) 20-3/4 (527) 34 (864) 5-13/32 (137) 1/2” (13mm) 1-1/2” (38mm) 36-23/32 (933) 20-3/4” (527) 37-7/8” (962) 1-7/8 (48) 6-1/16 (154) 14-3/4 (375) 21-1/16 (535) 1-1/2 (38) 8-7/32 (209) 18-3/4 (476) 14-3/4” (375) 23-1/2” (597) 1/2” (13) Facades Notes Cat. # Model Due to Lennox' ongoing commitment to quality, all specifications, ratings and dimensions are subject to change without notice. H5773 ADAGIO-AG Arch Black H5774 ADAGIO-PF Arch Br. Nickel H5775 ADAGIO-IG Iron Gates H5776 ADAGIO-CPD Copper Gates ** With the facade installed (required - sold separately), the appliance base will need to be elevated a minimum of 3/4" above the floor to allow for the proper fit of the facade (i.e. use 3/4" board minimum as platform). Corner Framing Dimensions - All Models Framing Dimensions * A filigree inset kit is also required (sold separately). See Care and Operation Manual for ordering information. Framing Dimensions - All Models A B C D E in. 22-1/8 41-5/8 29-1/2 10 20-7/8 mm 562 1057 749 254 530 A B C D in. 22-1/8 40-1/4 15-3/4 44-1/8 mm 562 1022 400 1121 VENT FRAMING TOP VENT WITH ONE 90° ELBOW Top Vent With Horizontal Termination In A Corner Corner Framing With SV4.5HT-2 Termination D 7 (178) � C Description 10-1/2 (267) 2 x 4 Header must be installed, vertical as shown to allow proper clearance from venting components to combustible header. See Figure 50 for more details. Inches (mm) 8 5-1/8 (130) E (203) 13-1/8 (333) D* B A Platform ** B C Inches Back wall of chase/enclosure When in a corner configuration, (millimeters)one of (including any installing finishing materials) u the rear stand-offs will need to be removed. P/N 775,617M, REV. A, 06/2008 Framing should be constructed of 2x4 or larger lumber A 3/4” Minimum from Finished Floor Page 1 of 2 Listing Information ADAGIO™-MN / ADAGIO-MP / ADAGIO-EN Input (BTU) - Millivolt Models Do not insulate the space between the appliance and the area above it. Natural (NG) & Propane (LP) Gas Models Fuel Input Rate (BTU / HR) Adagio-MN NG 13,000 (10,000 Low) Adagio-MP LP 13,000 (10,000 Low) Input (BTU) - Electronic Models Shelf Height 4” � (102mm) Drywall u 4" clearance is Natural (NG) & Propane (LP) Gas Models Fuel Input Rate (BTU / HR) Adagio-EN NG 13,000 (10,000 Low) Adagio-EP LP 13,000 (10,000 Low) US Models *Shelf Height (see table) Report No. 116-F-48-5 if field converted Secure Vent Secure Flex (flex elbow) *52 (1321) *53-3/4 (1365) * Includes 4” clearance to combustibles (required above vent components) 1/2 (13) - 0 (0) Spacers** Top Spacers 0 (0) Vent 12 (305) Mantel Combustible Materials Allowed In Shaded Area “Safe Zone” 8 (203) Mantel 0 (0)*** 64 (1626) 10 (254) Mantel 12" (305) 17" (432) inches (millimeters) 3 (76) Top * - 1 (25.4) Sides & Bottom 3 ft. (0.9 m) 16 (406) 5" Top View Of (127) Fireplace 45 ° Service Clearances -Feet (meters) Front Mantel Clearances Inches (mm) 2” (51) Minimum Clearance to Combustibles 1/2 (13) - 0 (0) Spacers Sides Bottom of Appliance To Ceiling Shelf Above Fireplace - Top Vent Side Wall Clearances (top view) Inches (millimeters) Floor Top Spacers Top Vent - with One 90 Degree Elbow Adagio-MN Adagio-MP Adagio-EN Back required above the elbow for installations that require an elbow at the top of the unit and that ends in a horizontal termination. Combustible Shelf Height - Inches (millimeters) Minimum Clearances Clearances Header Tested to ANSI Z21.88 (in Canada, CSA-2.33), and CAN/CGA-2.17-M91 in both USA and Canada, as vented gas fireplace heaters. 6 (152) Mantel 14 (356) 12 (305) 4 (102) Mantel 10 (254) Min. Distance 8-1/4” (210) to Protected Side Wall Side Wall 8 (203) 2 (51) Mantel Top Of Appliance 6 (152) Side Wall Min. Distance to Unprotected Side Wall 14" (356) Venting Requirements * Note: 3 in. (75 mm) above any horizontal vent component, except for installations which have and elbow connected to fireplace collar and that ends in a horizontal termination (this installation requires a 4” clearance above vent). ** Note: See Installation Instructions Manual on Page 6 (Step 1) for clearance requirements to the nailing flange located at each side of the unit and any screw heads adjacent to it. ***Note: To ensure proper fit of the facade, the appliance base will need to be elevated 3/4" above the floor to allow for the proper fit of the facade (i.e. Use 3/4" board as platform). Vertical Termination Cap SV4.5CGV-1 (rated for high winds and freezing conditions) Square Horizontal Termination (SV4.5HT-2) 12-1/8” (308 mm) Ceiling Framing 10-1/2 in. (267 mm) P/N 775,617M REV. A 06/2008 10-1/2” (267mm) 3" (76 mm) Adapter SV4.5RCH 1" (25.4 mm) 10-1/2 in. (267 mm) Printed in U.S.A. © 2007 Lennox Hearth Products Firestop / spacer (SV4.5HF) shown on the exterior side of the wall. It may also be installed on the interior side. 5-1/8” (130 mm) * Ceiling Firestop/ Spacer (SV4.5VF) Typical Installation 7" (178) 6 to 48 inch Vent Section, Telescopic vent section, Elbow or Appliance Collar Note: Center line of Vent Piping is NOT the Same as the Center line of the Framed Opening. See Page 1 for Min. Distance to Base of Appliance. Specifications and clearances are subject to change without notice. Refer to Installation Manual before installation of these appliances for updated dimensions and instructions. Page 2 of 2