Platinum Resistance Temperature Detector MN 222 MN- series PRTDs are designed for large volume applications where long term stability, interchangeability and accuracy over a large temperature range are vital. Typical applications are Automotive, White Goods, HVAC, Energy management, Medical and Industrial equipment. Nominal Resistance R0 100 Ohm at 0°C 500 Ohm at 0°C Toler ance DIN EN 60751 1996-07 Class A Class B Class 2B Class B Class 2B Tolerance DIN EN 60751 2009-05 F 0.15 F 0.3 F 0.6 F 0.3 F 0.6 Or der Number Plastic Bag Class A Class B Class 2B F 0.15 F 0.3 F 0.6 32 207 754 32 207 753 32 207 751 1000 Ohm at 0°C 32 207 32 207 32 207 32 207 32 207 759 758 757 756 755 The measuring point for the nominal resistance is defined at 8mm from the end of the sensor body. Specification DIN EN 60751 (according to IEC 751) Temperature range Tolerance Class A: Tolerance Class B: Tolerance Class 2B: -50°C to +300°C -70°C to +500°C -70°C to +500°C (temporary use at Cl. B and 2B to 550°C possibl e) Temperature coefficient TCR = 3850 ppm/K Leads Ni- wire Recommend connection technology: Welding and Brazing Lead lengths (L) 10mm ±1mm Ambient conditions Unhoused for dry environments only Insulation resistance > 100 MΩ at 20°C; > 2 M Ω at 500°C Self heating 0.4 K/mW at 0°C Response time water current (v= 0.4m/s): air stream (v= 2m/s): t0.5 = 0.05s t0.9 = 0.15s t0.5 = 3.0s t0.9 = 10.0s Measuring current 100Ω:0.3 to 1.0mA 500Ω:0.1 to 0.7mA 1000Ω:0.1 bis 0.3mA (self heating has to be considered) Application advice 1. To avoid shear forces on the connection area, the connection wires may be neither split or bent. The bending may only take place 3 mm after the element, using a bending or splitting tool. 2. Other nominal values, lengths and temperature coefficients on request. 3. Due to a production-caused oxide layer coating the leads, soft-soldering is restricted. Note Other tolerances, values of resistance are available on request. We reserve the right to make alterations and technical data printed. All technical data serves as a guideline and does not guarantee particular properties to any products. Heraeus Sensor Technology GmbH, Reinhard- Heraeus- Ring 23, 63801 Kleinostheim, Germany Phone: +49 (0) 6181/35-8098, Fax: +49 (0)6181/35-8101, E-Mail: info.HSND@Heraeus.com Web: www.heraeus-sensor-technology.com Name of document: 30910060 Index E Status: 06/2013