INSTALLATION INSTRUCTION ACCIAIO ® BX920 F L U O R E S C E N T 120V, 277V, 347V or 480V Input T5, T5HO, T8 WET LOCATION / IP66 Durable and Efficient Design R C US Chain mount (chain optional) Surface mounting bracket Safety cable EACH MODEL NUMBER CONSISTS OF THE FOLLOWING: SERIES / SIZE / OPERATION / LAMP & BALLAST / INPUT Steel Housing Die-cast aluminum end cap Model: BX920 Operation HT (AC Only) SA (AC & Emergency) Lamps Input 217WT8 214WT5 224WT5HO 228WT5 232WT8 254WT5HO 120V / 277V 347V or 480V Tempered glass Stainless steel lock screw IMPORTANT SAFEGUARDS WARNING No User serviceable parts. Refer service to a qualified service technician. Read instructions prior to installing and /or operating this device. Installation should be performed by a licensed electrician / installer in accordance with local codes. IMPORTANT SAFETYGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS - Do not let power cords touch hot surfaces. - Do not mount near gas or electric heaters. - Equipment should be mounted in locations and at heights where unauthorized personnel will not readily subject it to tampering. - The use of accessory equipment not recommended by Beghelli Inc, may cause an unsafe condition, and will void the warranty. - Do not use this equipment for other than its intended purpose. - Servicing of this equipment should be performed by qualified service personnel. SAVE THESE INSTRUCTIONS! 012612 INSTALLATIONGUARDS 1. Make sure the main power is off. 2. Attach and secure ACCIAIO® mounting brackets to surface. Use appropriate fasteners. 3. Assemble safety cable on safety bracket (top of the fixture). 4. Connect safety cables to already installed mounting brackets. 5. Bring the fixture up and snap mounting bracket onto housing side channels. 6. Connect labeled wires to main power. RELAMPING 1. Detach mounting brackets from housing having the fixture hang from safety cables (If there is 48” clearance on site this process is not necessary see) (figures 2, 3 & 4) 2. Unlock screw from NON-FEED end cap and take end cap off. 3. Extract security crossbar (up – out motion) 4. Partially or completely slide out rail system until lamps are accessible. 5. Repeat the same process in reverse to close and seal the unit. Beghelli Canada Inc. 3900 14th Avenue Markham, Ontario L3R 4R3 Canada Tel (905) 948-9500 Fax (905) 948-8673 www.BeghelliLuce.com INSTALLATION 1 Safety cable G N L 2 Connect wires to main power. (36” standard line cord provided) power is off 4 Attach mounting brackets to surface. G N L Snap fixture to brackets. 3 5 G N Electrical hardware (provided by others) BLACK / HOT WHITE / NEUTRAL 6 GREEN /GROUND Bracket L 1. Make sure the main power is off. ® 2. Attach and secure ACCIAIO mounting brackets to surface. Use appropriate fasteners. 3. Connect safety cable to both brackets (top of the fixture). 4. Connect safety cables to already installed mounting brackets. 5. Bring the fixture up and snap mounting bracket onto housing side channels. 6. Connect labeled wires to main power. Fixture completely installed. RELAMPING 1 2 Detach luminaire from stainless steel, surface mount brackets. Unit is held by two safety cables that allow the ACCIAIO® to drop down approximately 12” for easy accesibility. Loosen lock screw to release non-feed, die-cast end cap. NOTE: UNIT DOES NOT HAVE TO BE DROPED DOWN IF YOU HAVE 48“ BETWEEN UNITS 3 4 Unlock crossbar bracket in an up and out motion to gain access to the ballast and lamp rail system. All linear two (2) lamp configurations feature a single ACCIAIO® rail system. Ratchet sockets must be turned for lamp removal. Reverse all steps to close and secure ACCIAIO® INSTALLATION INSTRUCTION ACCIAIO ® BX940 F L U O R E S C E N T 120V, 277V, 347V or 480V Input T5, T5HO, T8 WET LOCATION / IP66 Durable and Efficient Design R C US Chain mount (Chain optional) Mounting bracket Safety cable EACH MODEL NUMBER CONSISTS OF THE FOLLOWING: SERIES / SIZE / OPERATION / LAMP & BALLAST / INPUT Model: BX940 Operation HT (AC Only) Die-cast aluminum end cap SA (AC & Emergency - one lamp) SA (AC & Emergency - two lamp) Steel Housing Lamps Input 432WT8 428WT5 454WT5HO 120V / 277V 347V or 480V Tempered glass Stainless steel lock screw IMPORTANT SAFEGUARDS WARNING No User serviceable parts. Refer service to a qualified service technician. Read instructions prior to installing and /or operating this device. Installation should be performed by a licensed electrician / installer in accordance with local codes. IMPORTANT SAFETYGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS - Do not let power cords touch hot surfaces. - Do not mount near gas or electric heaters. - Equipment should be mounted in locations and at heights where unauthorized personnel will not readily subject it to tampering. - The use of accessory equipment not recommended by Beghelli Inc, may cause an unsafe condition, and will void the warranty. - Do not use this equipment for other than its intended purpose. - Servicing of this equipment should be performed by qualified service personnel. SAVE THESE INSTRUCTIONS! 012612 INSTALLATIONGUARDS 1. Make sure the main power is off. 2. Attach and secure ACCIAIO® mounting brackets to surface. Use appropriate fasteners. 3. Assemble safety cable on safety bracket (top of the fixture). 4. Connect safety cables to already installed mounting brackets. 5. Bring the fixture up and snap mounting bracket onto housing side channels. 6. Connect labeled wires to main power. RELAMPING 1. Detach mounting brackets from housing having the fixture hang from safety cables (If there is 48” clearance on site this process is not necessary see) (figures 2, 3 & 4) 2. Unlock screw from NON-FEED end cap and take end cap off. 3. Extract security crossbar (up – out motion) 4. Partially or completely slide out rail system until lamps are accessible. 5. Repeat the same process in reverse to close and seal the unit. Beghelli Canada Inc. 3900 14th Avenue Markham, Ontario L3R 4R3 Canada Tel (905) 948-9500 Fax (905) 948-8673 www.BeghelliLuce.com INSTALLATION 1 2 Connect wires to main power. (36” standard line cord provided) power is off Safety cable 4 Attach mounting brackets to surface. G N L Snap fixture to brackets. 5 3 Bracket G N BLACK / HOT WHITE / NEUTRAL 6 GREEN /GROUND Electrical hardware (provided by others) L 1. Make sure the main power is off. ® 2. Attach and secure ACCIAIO mounting brackets to surface. Use appropriate fasteners. 3. Connect safety cable to both brackets (top of the fixture). 4. Connect safety cables to already installed mounting brackets. 5. Bring the fixture up and snap mounting bracket onto housing side channels. 6. Connect labeled wires to main power. Fixture completely installed. RELAMPING 1 2 Detach luminaire from stainless steel, surface mount brackets. Unit is held by two safety cables that allow the ACCIAIO® to drop down approximately 12” for easy accesibility. 3 Loosen lock screws to release non-feed, die-cast end cap. End cap is supported by a safety cable for easy maintenance. 4 Unlock crossbar bracket in an up and out motion to gain access to the ballast and lamp rail system. Crossbar is supported by the safety cable. All linear four (4) lamp configurations feature two, independent ACCIAIO® rail systems. Reverse all steps to close and secure ACCIAIO® INSTALLATION INSTRUCTION ACCIAIO BX950 ® single COMPACT FLUORESCENT 120V/277V, 347V or 480V Input WET LOCATION / IP66 Durable and Efficient Design R C Chain mount (Chain optional) Surface mounting bracket EACH MODEL NUMBER CONSISTS OF THE FOLLOWING: SERIES / OPERATION / LAMP / INPUT Model: BX950 Operation HT (AC Only) Die-cast aluminum end cap Steel Housing Lamps 236W CF 255W CF Input 120V/277V 347V or 480V Tempered glass lens Stainless steel lock screw IMPORTANT SAFEGUARDS INSTALLATIONGUARDS WARNING No User serviceable parts. Refer service to a qualified service technician. Read instructions prior to installing and /or operating this device. Installation should be performed by a licensed electrician / installer in accordance with local codes. IMPORTANT SAFETYGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS - Do not let power cords touch hot surfaces. - Do not mount near gas or electric heaters. - Equipment should be mounted in locations and at heights where unauthorized personnel will not readily subject it to tampering. - The use of accessory equipment not recommended by Beghelli Inc., may cause an unsafe condition, and will void the warranty. - Do not use this equipment for other than its intended purpose. - Servicing of this equipment should be performed by qualified service personnel. SAVE THESE INSTRUCTIONS! 012612 1. Make sure the main power is off. 2. Attach and secure ACCIAIO® mounting brackets to surface. Use appropriate fasteners. 3. Bring the fixture up and snap mounting bracket onto housing side channels. 4. Connect labeled wires to main power. RELAMPING 1. Loosen stainless steel lock screw from feed end cap 2. Release feed, die-cast end cap 3. Slide out rail system to access the ballast and lamps. 4. Disengage and remove lamps from sockets Reverse all steps to close and secure ACCIAIO® Beghelli Canada Inc. 3900 14th Avenue Markham, Ontario L3R 4R3 Canada Tel (905) 948-9500 Fax (905) 948-8673 www.BeghelliLuce.com US INSTALLATION 1 Connect wires to main power. (72” standard line cord provided) 2 power is off Attach mounting brackets to surface. G N L 3 WHITE / NEUTRAL BLACK / HOT 4 GREEN /GROUND Canopy kit (provided by others) G N L Fixture completely installed. Snap fixture to brackets. 1. Make sure the main power is off. 2. Attach and secure ACCIAIO® mounting brackets to surface. Use appropriate fasteners. 3. Bring the fixture up and snap mounting bracket onto housing side channels. 4. Connect labeled wires to main power. RELAMPING 1 2 Loosen stainless steel lock screw from feed end cap 3 Release feed, die-cast end cap. 4 Grasp here and pull Slide out rail system to access the ballast and lamps. Disengage and remove lamps from sockets Reverse all steps to close and secure ACCIAIO® INSTALLATION INSTRUCTION ACCIAIO BX950 ® duo COMPACT FLUORESCENT 120V/277V, 347V or 480V Input WET LOCATION / IP66 Durable and Efficient Design R C US Surface mounting bracket EACH MODEL NUMBER CONSISTS OF THE FOLLOWING: SERIES / OPERATION / LAMP / INPUT Die-cast aluminum end cap TER IT UN Model: BX950 duo S MA E AV SL IT UN Operation HT (AC Only) Lamps 436W CF 455W CF Input 120V/277V 347V or 480V Steel Housing Tempered glass lens Jumper cable (with watertight connectors) Stainless steel lock screw IMPORTANT SAFEGUARDS INSTALLATIONGUARDS WARNING No User serviceable parts. Refer service to a qualified service technician. Read instructions prior to installing and /or operating this device. Installation should be performed by a licensed electrician / installer in accordance with local codes. IMPORTANT SAFETYGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: 1. Make sure the main power is off. 2. Attach and secure ACCIAIO mounting brackets to surface. (Use appropriated fasteners) 3. Bring MASTER fixture up and snap mounting brackets onto housing side channels. 4. Bring SLAVE fixture up and snap mounting brackets onto housing side channels. 5. Connect MASTER and SLAVE using jumper cable with watertight connectors. 6. Connect MASTER fixture to main (AC) power following labels information. 7. Turn ON power. READ AND FOLLOW ALL SAFETY INSTRUCTIONS RELAMPING - Do not let power cords touch hot surfaces. - Do not mount near gas or electric heaters. - Equipment should be mounted in locations and at heights where unauthorized personnel will not readily subject it to tampering. - The use of accessory equipment not recommended by Beghelli Inc., may cause an unsafe condition, and will void the warranty. - Do not use this equipment for other than its intended purpose. - Servicing of this equipment should be performed by qualified service personnel. 1. Disconnet MASTER and SLAVE from jumper cable loosen stainless steel lock screw from feed end cap. 2. Release feed, die-cast end cap 3. Slide out rail system to access the ballast and lamps. 4. Disengage and remove lamps from sockets Reverse all steps to close and secure ACCIAIO® SAVE THESE INSTRUCTIONS! 012612 Beghelli Canada Inc. 3900 14th Avenue Markham, Ontario L3R 4R3 Canada Tel (905) 948-9500 Fax (905) 948-8673 www.BeghelliLuce.com INSTALLATION 1 2 Connect wires to main power. (72” standard line cord provided) G N L power is off GREEN /GROUND WHITE / NEUTRAL BLACK / HOT 6 Attach mounting brackets to surface. G N L Snap fixture to brackets. 14.370 3-4-5 Canopy kit (provided by others) 3.150 Fixture completely installed. 1. Make sure the main power is off. 2. Attach and secure ACCIAIO mounting brackets to surface. (Use appropriated fasteners) 3. Bring MASTER fixture up and snap mounting brackets onto housing side channels. 4. Bring SLAVE fixture up and snap mounting brackets onto housing side channels. 5. Connect MASTER and SLAVE using jumper cable with watertight connectors. 6. Connect MASTER fixture to main (AC) power following labels information. 7. Turn ON power. RELAMPING 1 2 Disconnet master and slave from jumper cable, loosen stainless steel lock screw from feed end cap. 3 Release feed, die-cast end cap. 4 Grasp here and pull Slide out rail system to access the ballast and lamps. 12.539 Disengage and remove lamps from sockets Reverse all steps to close and secure ACCIAIO®. INSTALLATION INSTRUCTION ACCIAIO ® BX960 Flood COMPACT FLUORESCENT R 120V/277V, 347V or 480V Input WET LOCATION / IP66 Durable and Efficient Design Mounting Bracket C US Aluminum non-feed die-cast end cap U Bracket EACH MODEL NUMBER CONSISTS OF THE FOLLOWING: SERIES / OPERATION / LAMPS / INPUT Aluminum feed die-cast end cap Model: Steel Housing BX960 Flood Operation HT (AC Only) Lamps Input 236W CF 255W CF 120V/277V 347V or 480V Stainless steel lock screw Tempered glass lens IMPORTANT SAFEGUARDS INSTALLATIONGUARDS WARNING No User serviceable parts. Refer service to a qualified service technician. Read instructions prior to installing and /or operating this device. Installation should be performed by a licensed electrician / installer in accordance with local codes. IMPORTANT SAFETYGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS - Do not let power cords touch hot surfaces. - Do not mount near gas or electric heaters. - Equipment should be mounted in locations and at heights where unauthorized personnel will not readily subject it to tampering. - The use of accessory equipment not recommended by Beghelli Inc., may cause an unsafe condition, and will void the warranty. - Do not use this equipment for other than its intended purpose. - Servicing of this equipment should be performed by qualified service personnel. Make sure the main power is off: Loosen lock screw and detach feed die-cast end cap. Loosen set screws / Slide mounting brackets onto housing through channels. Position mounting brackets 12” apart (keep set screws loose until final adjustment). Mount U bracket on desired surface against the containment and use proper fasteners (provided by others). Mount the fixture on installed U bracket using provided screws. Tighten set screws. Adjust desired angle. Connect labeled wires to main power. Turn ON power. RELAMPING 1. Loosen stainless steel lock screw from feed end cap and release. 2. Release feed die-cast end cap 3. Slide out rail system to access the ballast and lamps. 4. Disengage and remove lamps from sockets. Reverse all steps to close and secure ACCIAIO®. SAVE THESE INSTRUCTIONS! 021712 Beghelli Canada Inc. 3900 14th Avenue Markham, Ontario L3R 4R3 Canada Tel (905) 948-9500 Fax (905) 948-8673 www.BeghelliLuce.com INSTALLATION Containment tab 1 2 Loosen only (Do not remove) Set screw (2) Slide mounting brackets onto housing up to containment tab. Detach feed die-cast end cap. 3 4 12.0” Angle adjustment Tighten set screw N L G Position brackets at (12”) apart attach feed die-cast end cap. Use proper fasteners (provided by others) Final mounting and adjustment. RELAMPING 1 2 Loosen stainless steel lock screw from feed die-cast end cap. 3 Release feed die-cast end cap. 4 Grasp here and pull Slide out rail system to access the ballast and lamps. Disengage and remove lamps from sockets Reverse all steps to close and secure ACCIAIO®.