Annexure- I 1. DIGITAL AUTOCLAVE HORIZONTAL : TECHNICAL SPECIFICATION OF DIGITAL AUTOCLAVE HORIZONTAL Application : This equipment will be necessary for sterilization of the glassware’s and other apparatus. No. Technical Specification of GEER Foundation 1 Capacity: Different capacity up to 150. 2 4 Mode of Heating: High quality electric heater bearing ISI mark. Working Pressure: The pressure inside the chamber is variable from 5 psi. To 20 psi. But the normal recommended pressure for sterilization process is 1.2 kg/cm sq.g ( 15 psi - 17 psi ) Working Temperature : 121° C 5 Hydro test Pressure : 35 psi 6 Multiple Operating Valve : To carry out all functions of sterilization cycle at one point i.e. steam to jacket, steam to chamber, fast/ slow exhaust and vacuum/ drying. Door: Single door shall be fitted with radical shooting arm, provided with automatic pressure locking device so that the door cannot be opened till chamber pressure is fully exhausted. Quick Vacuum Drying Apparatus: This Allows the filtered and sterilized air to break the chamber vacuum & helps in quickdrying. Accidental Vacuum Breaker: A safety device so jacket against accidental vacuum in it and to remove residual air from it. Safety Valve: A safety device against excess pressure in jacket and steam generator. Dial Type Thermometer: Indicates sterilization temperature. Plug Screen: A device to prevent chamber, discharge line from lint / sediment. 3 7 8 9 10 11 12 13 14 Chamber Condensate Line: Incorporated with spirax thermostatic steams trap and check valve for perfect condensation from chamber to achieve optimum temperature. Pressure & Compound Gauge: Indicates jacket and chamber pressure / vacuum resp. Compare to Specification (Yes or No) Vendor’s specification as per model Remarks of GEER Foundation (Technical committee) Annexure- I 2. Soil Sampler: TECHNICAL SPECIFICATION OF SOIL SAMPLER (CORE SAMPLER) Applications: Collection of Soil Samples from Hard Rock, Inter-tidal Zone Vendor’s specification No. Technical Specification of GEER Compare to as per model Foundation Specification (Yes or No) 1 7 The equipment should have a capacity to penetrate in hard rocky materials and soils of inter-tidal zones or in coastal land cover. The set of the equipment should contain the following Equipments: Soil Sampling Tube – it should allow further extension of the tube for deeper sampling. Made up of stainless steel material or non-corrosive material Outside Diameter: as per model and model preferable to coastal area sampling Inside Diameter: as per model and model preferable to coastal area sampling Length: up to 70 cm , extendible or as per model and model preferable to coastal area sampling Retaining Cylinder: stainless steel, alsoavailable in plastic, brass, andTeflon and in custom lengths or expandable light weight 8 Frame: Steel based durable frame 9 10 Extension tubes: Number of extension tubes for deeper sampling Cutting tips: Replaceable 11 Hammer: Stainless Steel 12 Cleaning Apparatus: As applicable 13 HandleExtension Rod: extension Rod for deeper samplingSuitable for marine soilSupply with non-corrosive case 2 3 4 5 6 Remarks of GEER Foundation (Technical committee) Annexure- I 3. pH meter for Soil: TECHNICAL SPECIFICATION OF pH meter for Soil APPLICATIONS: This equipment would be required for the analysis of soil No. Technical Specification of GEER Foundation Sensor:Tough spear tip glass and open pore sensor 1 2 3 4 5 6 7 8 9 10 Range: pH: 0.0 to 14.00 mV: ±1600 Temperature, °C: 0 to 100 Resolution: pH: 0.01 mV: ±0.1 Temperature, °C: 0.1 Accuracy: pH: ±0.01 mV: ±0.01 Temperature, °C:±0.5 Display: Large dual display screen Temperature compensation: Automatic 0 to 100°C Buffer recognition: Automatic and manual Power: 9V Battery and 230 VAC adapter Calibration: Minimum 3 Stage (4.0, 7.0 and 10.0 pH) Or multistage calibration with additional buffer solution of pH 2,5, 8 & 9 etc. pH buffers pouches: 4.0, 7.0 and 10.0 pH ( traceable to NABL) Combined (pH + temp)electrodes : Two (One as spare) Compare to Specification (Yes or No) Vendor’s specification as per model Remarks of GEER Foundation (Technical committee) Annexure- I 4. Thermometer for Soil: TECHNICAL SPECIFICATION OF THERMOMETER FOR SOIL Application: Measurement temperature of Water and Soil No. Technical Specification of GEER Foundation Compare to Specification (Yes or No) 1 Pocket Thermometer 2 Waterproof 3 Temperature range :0oC - 100oC 4 Accuracy level :+1°C 5 Repeatability: +0.2oC 6 Resolution : 0.1o C 7 Sampling time :400 to 500 ms 8 Power: Battery 9 Storage temperature : 10 to 60oC 10 o C / o F switchable : yes 11 Function: max/ min 12 Piercing Probe Length:5’’ Rust proof stainless steel probe Vendor’s specification as per model Remarks of GEER Foundation (Technical committee) Annexure- I 5. Water Sampler: TECHNICAL SPECIFICATION OF WATER SAMPLER Applications: This sampler would be required for collection of water samples. Vendor’s specification as No. Technical Specification of GEER Foundation Compare to per model Specification (Yes or No) 1 2 3 4 5 6 7 8 9 Capacity 2 ltr to 5 liter Made up of PVC materials or non-corrosive material Weight: light weight With messenger and cable Soft rubber balls and seals The ballasted bottom allows an excellent vertical stability when immerged The automatic opening system enables sampling at different water depths ranging from 0 to 60 meters. We include 60 m of line on a foam winding float that will bob to the surface if it falls into the water. Suitable for Marine Depth Water Supply with non-corrosive case Remarks of GEER Foundation (Technical committee) Annexure- I 6. Conductivity Meter: TECHNICAL SPECIFICATION OF CONDUCTIVITY METER FOR SOIL Application : Standard Device for Testing Water & Soil Electrical Conductivity No. Technical Specification of GEER Foundation Compare to Vendor’s specification as Specification per model (Yes or No) 1 Body Material: stainless steel or water proof 2 Probe: : Tough spear tip glass and open pore 3 Cable length:30 m 4 Conductivity resolution: 0.01 μS/cm (5 digits, maximum) 5 Measuring range conductivity: 0.01 μS/cm to 200 mS/cm 6 Parameter: Conductivity 7 Calibration:Auto calibration 8 Special Feature: Rugged 9 Temperature accuracy: 0.3 °C °C (±0.54 °F) 10 Temperature Range: 0 to 110 °C 11 Temperature range: conductivity: Continuous use: 0 to 110 °C °C 12 Temperature resolution: 0.1 °C 13 Weight:Light in weight 14 Battery operated probe orspecially for soil samples Remarks of GEER Foundation (Technical committee) Annexure- I 7. Secchi Disk: TECHNICAL SPECIFICATION OF SECCHI DISK Application: Standard Device for Testing Water Clarity or Turbidity No. Technical Specification of GEER Foundation Compare to Specification (Yes or No) 1 Oceanographic weighted secchi disc 2 3 Constructed of white high density polyethylene Stainless steel body 4 50 cm diameter or more 5 Weights and instructions included 6 20 m nylon cord and reel 7 Carrying case Vendor’s specification as per model Remarks of GEER Foundation (Technical committee)