Vantage Technology Explosionproof Connectors Vantage Technology LLC Englewood, Colorado USA Phone 303-761-2121 VantageXP.com Explosionproof Connectors for Hazardous Locations Third-party certification to North American Divisional standards and ATEX Zonal standards means Vantage connectors meet hazardous area safety and installation requirements throughout the world. 4675 South Windermere Street – Englewood, Colorado 80110 – Ph: 303.761.2121 – FAX: 303.789.4215 – Email: Support@VantageXP.com Table Of Contents Page 3 Table of Contents Company Overview 4 Vantage Product Overview 5 Assurance, Third Party Certificates 6 Explosionproof StarLine Explosionproof StarLine Features Power - Victory Series 7 8-9 Motor Minder Electrical Interlock 10 GD Part Numbers 11 GB Part Numbers 12 BM Part Numbers 13 Control - Victory Series 14-15 AF Part Numbers 16-17 Stainless Steel - Millennium Series 18-19 SD Part Number 20 SB Part Numbers 21 SF Part Numbers 22-23 Aircraft and Ground Power Ground Power Part Numbers Explosionproof StarLine ATEX Power and Control Insert and Contact Options Insert Configurations 24 25 26-27 28 29-36 Environmental Sealing 37 Tooling 38 Dimensions 39-41 Part Number Code Logic GD, SD and BM Receptacles 42 GD, SD and BM Cable Attachments 43 AF, SF and BM Receptacles 44 AF, SF and BM Cable Attachments 45 Ground Power Receptacle, Single 46 Ground Power Receptacle, Duplex 47 StrateLine Delayed Action StrateLine Interlocked StrateLine 48-50 51 Part Number Code Logic EP and ER 52 YX and PX 53 Engineering Support 54 Applications 55 Vantage Sales Team 56 Page 3 VANTAGE Explosionproof electrical connectors are designed for use in Hazardous Locations defined by the National Fire Prevention Association (NFPA) National Electrical Code, Article 500 Hazardous (Classified) Locations, Classes I, II, and III, Divisions 1 and 2. Vantage is proud to maintain certifications of that suitability from nationally recognized testing laboratories, including Underwriters Laboratories, Inc (UL), CSA International (CSA) and MSHA – Mines Safety and Health Act. Product nameplates carry relevant listing data, and copies of certifications are available upon request. Vantage connectors are certified by CSA-KEMA to the ATEX Directive 94/9/EC, Equipment and Protective systems intended for use in Potentially Explosive Atmospheres. Manufactured in Colorado, USA and shipped throughout the world, the following connector products are offered by Vantage Technology. No matter what the hazardous location … No matter what the application … VICTORY SERIES Third Party Certified explosionproof connectors providing safe and reliable service. GD and GB Power BM Mining AF and BM Control GD Ground Power EP / ER Power PX / YX Power MILLENNIUM SERIES At the start of the third millennium, Vantage introduced the first and only stainless steel power connectors certified for use in Class I, Division 1 areas. Also available in combination nickel aluminum bronze, these include: Explosionproof – Make It / Break It Safe, Fast and Easy SB Power SD Power SF Control MISSION At Vantage, our mission is to be the premier manufacturer of third-party certified explosionproof connectors while providing the best customer service. We pride ourselves on having the personnel, experience and knowledge to meet these goals with • • • • • Technical Service Reliable Delivery Engineering Support Third Party Certification New Product Development VANTAGE Explosionproof connectors assure safe, reliable interconnects. With worldwide service, on land-based facilities or offshore drilling platforms, in aerospace, petroleum, process manufacturing, chemicals, mining and other industries, Vantage provides the quality solutions you demand. Page 4 Page 5 Vantage has earned a broad range of system and product third party certifications. Our company meets the requirements of ISO 9001:2000. Quality standard EN13980 augments our system and sets the foundation for the requirements of the ATEX Directive. Products throughout this catalog list relevant third party certified ratings. This is your assurance that when you specify our connectors, they will meet or exceed your requirements. Quality Policy Our employees are committed to providing our customers with the safest and most reliable products possible at a level of service which ensures that the correct product is selected for the customer’s application, is installed correctly, and is maintained for a long, safe life. We are committed to building lasting relationships with our customers. Our company wide goal is customer satisfaction, continuous improvement, process management, and employee involvement to ensure success for our customers and the company. Quality Certificates Quality System Certificate Product Quality Assurance Notification Quality Standard ISO 9001:2008 Certificate Number: CERT-03456-2001-AQ-HOU-RAB Equipment or Components intended for use in potentially explosive atmospheres Directive 94/9/EC. Notification Number: DNV-OSL-ATEX-2571Q Det Norske Veritas Det Norske Veritas Product Certificates CSA International Underwriters Laboratories File Number: RROR.E12145 Category Name: Receptacles With Plugs, For Use in Hazardous Locations Certification Record Class 6238-01 Class Description: Receptacles and Plugs - For Hazardous Locations Class I, Group B Class I, Division 2, Group B Class I, Group C and D Class I, Division 2, Groups C and D Certification Record Class 6238-81 Class Description: Receptacles and Plugs - For Hazardous Locations Certified to U.S. Standards File Number: RSPX.E12145 Category Name: Receptacles With Plugs Interlocked With Switches, For Use in Hazardous Locations X/P 1570 …Sump Pumps II 2 GD Page 6 Class I, Division 1, Group D; Class II, Division 1, Groups F and G Occupational Safety and Health Administration Mine Safety and Health Administration CSA International- KEMA Class I, Groups B, C and D and Class II, Groups F and G Class I, Division 2, Groups B, C and D and AEx d IIC T6 Certification Record Class 6238-03 Class Description: Receptacles with Switch and Plugs - For Hazardous Locations. YX and PX Series Class I, Group C and D Class II, Groups F and G Connector Certifications: X/P 1344 …BM Control X/P 1344 …BM Power Class I, Groups B, C and D and Class II, Groups F and G Class I, Division 2, Groups B, C and D and Ex d IIC T6 Approved use of Vantage BM connectors in Class II, Group F hazardous areas. EC Type Examination Certificate Number KEMA 04ATEX2179 X EEx d IIC T6 (Receptacles and Plugs) EEX d IIB +H2 T6 (Ground Power Receptacles) IP 66/67, T 70°C The Vantage StarLine Series of explosionproof connectors is offered in a variety of materials and configurations. Product options and an array of third party listings mean we have a solution for your application. Note, options and features may vary based on third party listing. PLUG, ATTACHMENT RECEPTACLE, JUNCTION BOX PLUG, TAPPED NPT RECEPTACLE, NPT Features Sealing. All junction box, NPT and panel mount receptacles are pre-wired and factory sealed eliminating the need for external seals. Purged / Pressurized Systems. Factory sealing makes our receptacles ideal for use with these technologies. Options Covers. Environmental threaded covers are available with all connectors. Pigtails. Receptacle leads may be ordered in any length. Gender. Connectors can be supplied with reverse service inserts when lineside power is carried in the plug to the receptacle. Keying. Inserts can be keyed for phase and voltage separation. Color Coding. Connectors may be ordered in a range of colors and combinations of color. Custom Assemblies. Are available to user’s specifications. RECEPTACLE, PANEL MOUNT RECEPTACLE, ATTACHMENT RECEPTACLE, TAPPED NPT Victory Series Machined, hard anodized aluminum GD Power Page 8 GB Power Page 8 AF Control Page 14 BM Power Page 8 II 2 GD EEx d IIC T6 IP 67 T 70°C Class I, Groups B, C & D Class II, Groups F & G Class I, Groups B, C & D Class II, Groups F & G Class I, Groups B, C & D Class II, Groups F & G Class I, Groups C & D Class I, Groups B Class II, Group F Millennium Series Stainless steel, alloy 316 SD Power Page 18 SF Control Page 18 II 2 GD EEx d IIC T6 IP 67 T 70°C Class I, Groups B, C & D Class II, Groups F & G Class I, Groups B, C & D Class II, Groups F & G Page 7 Vantage Technology presents explosionproof connectors designed to UL Standard 1010 and the ATEX Directive. They are intended for use in areas which are hazardous per the U.S. and Canadian electrical codes and Explosive Atmospheres per 94/9/EC. The Victory Series has a proven track record with over 40 years of safe and reliable service. Since its inception, the Victory connector remains the only third party certified explosionproof connector with a rating over 100 amperes. Vantage provides circuit-breaking make-and-break connections at up to 200 amperes in a small, environmentally sealed package. GD, GB and BM connectors features include: Third Party Certification ... Vantage connectors have been tested and listed for use in hazardous areas by the following organizations: UL Underwriters Laboratories, Inc. CSA CSA International MSHA Mine Safety - U.S. Bureau of Mines ATEX EC Type-Examination Certificate with KEMA Power Inserts 30, 60, 100 and 200 amp rated for service through 600 Vac and designed for Class I and II Areas, per the U.S. and Canadian electrical codes. 32, 63, 125, and 260 amp rated for service through 1000 Vac, 500 Vdc and approved to II 2 GD EEx d IIC T6, per 94/9/EC Circuit-Breaking UL, CSA and MSHA Listed to make/break at full rated load, these connectors were required to pass an overload test of 50 cycles at 150% of their ampere rating in a chamber filled with a test mixture of hazardous vapors. Submersible Victory and Millennium series connectors are both explosionproof and submersible! When fully mated, they will withstand 200 PSI of external as well as 100 PSI of internal pressure. 400 Amp Connector Vantage 400 amp XP connectors are electrically interlocked. The receptacle, with UL / CSA listed components, is wired to a breaker with shunt trip for enhanced safety. Page 8 (See pages 26 and 27 for ATEX details.) Insert Patterns Grounding inserts with 3, 4, 5, and 6 contacts are described as 2 Pole 3 Wire, 3 Pole 4 Wire, 4 Pole 5 Wire, and 3 Pole 4 Wire plus 2 relay length contacts. The ground pin is longer and will make first - break last, an important safety feature. See pages 29-32 for inserts. Corrosion Resistance Designed for corrosive environments, junction boxes are sand cast, copper-free aluminum, protected by our VanGuard baked polymer finish system. Plug and receptacle shells are machined from 6061-T6 aluminum (0.15 to 0.40% copper by weight) and finished by hard anodizing to exceed corrosion resistance requirements per MIL-STD 202, Method 101, Condition D. Reverse Service GB / GD connectors are the first and only explosionproof connectors to secure both UL and CSA listing with reverse service inserts. Their ATEX listing also supports reverse service. This feature provides electrical safety where lineside power is carried from the plug to a receptacle. 200 Amp Connector UL, CSA and MSHA listed in what is now recognized as a landmark achievement by a connector manufacturer. Factory Sealing Junction box, NPT and panelmounted receptacles are pre-wired and factory sealed. No external seals are required. Attachment Receptacles Sometimes called in-line or cable-mounted, they are available with backshell variations and watertight threaded covers. With this design, assemblies can be built in extension cord fashion. Panel Mount Receptacles GB / GD panel-mounted receptacles are CSA Listed at 30, 60, 100 and 200 amps for Class I, Division 2 and Class II, Division 2 areas. These prewired and factory sealed receptacles are available with wire leads of any specified length. NPT Mount Receptacle Vantage developed NPT receptacles to thread into explosionproof enclosures. Prewired and factory sealed, these CSA Listed receptacles can be supplied with wire leads of any length. They are available in the following sizes: Shell Size 16 - 1½" NPT Shell Size 24 - 2½" NPT Shell Size 20 - 2" NPT Shell Size 28 - 3" NPT Flexible Conduit Attachment plugs and receptacles are available with backshell hardware for use with explosionproof, flexible conduit in Division 1 areas and liquid tight flexible conduit in Division 2 areas. Electrical Interlock Switch Receptacles with junction boxes are available with this variation, often used as a motor disconnect. The normally open switch is operated automatically by insertion/withdrawal of the mating plug. Reference Motor Minder XP Connectors on page 10. Color Coding Plugs and receptacles are available with color coding variations for specific application identification. This coding could include the plug coupling nut and cover with matching colors on various receptacle components. Cable Assemblies Vantage connectors are available as complete assemblies built to your specification and shipped to any site, ready-to-install. Ground Power Receptacles UL, CSA & ATEX listed Ground Power receptacles mount flush into a concrete deck or platform. Each unit is available with one or two power receptacles and various point-of-use controls. 60/400 Hertz listings make them ideal for use in aircraft hangar applications. See page 24 for product details. Alternate Keyed Inserts For added safety, inserts can be keyed in alternate positions to prevent mating of differing voltages, frequencies or services. Shell Size 16 – 1¼" NPT Shell Size 20 – 1½" NPT Shell Size 24 - 2" NPT Shell Size 28 – 2½" NPT INSERT GDU-28-31 KEY NUMBER KEY POSITION N 01 02 03 0° 60° 120° 195° See Pages: 11-13 and 25 for Part Numbers 42-43, 46-47 for Part Number Code Logic 39-41 for Product Dimensions PIN NUMBER 4 IS POLARIZED Page 9 Vantage explosionproof StarLine receptacles can be supplied with an Electrical Interlock Switch, which is ideal for applications such as motor disconnect and remote signaling. Wired to a contactor or circuitbreaker with shunt trip, this variation insures the connectors will make-break under a no-load condition. Engagement and separation of pins and sockets is controlled by the snap-action mechanism incorporated in Motor Minder XP connectors. Example P/N: GD-B1720-40SL-AH-94 The 94 suffix calls for an interlocking switch in a control circuit (24V – 600V) with a PC, contactor or circuit breaker with a shunt trip or undervoltage release. The stainless steel pushbutton assembly, preinstalled within enclosure, is supplied with 8" pigtails for simplified field termination. Separation Unthreading the coupling sleeve opens the interlock switch by releasing the springloaded actuator, before pins are withdrawn from the sockets. Further rotation controls the separation of pins from sockets under a no-load condition. Engagement – The snap-action mechanism engages pins into sockets. An additional 3-4 turns of the couplings sleeve closes the interlock switch by depressing the actuator, energizing a fully mated connection that is sealed against the environment. Page10 AMPERES Plug, Attachment 1 Plug, NPT 1,4 Receptacle, Junction Box Receptacle, NPT 3 Receptacle, Panel Mount Receptacle, Attachment Receptacle, NPT 5 1 2 POLE, 3 WIRE 3 POLE, 4 WIRE 4 POLE, 5 WIRE 30 32 GD-1016-51PL-XX GD-1016-23PL-XX GD-1020-36PL-XX 60 63 GD-1020-61PL-XX GD-1020-40PL-XX GD-1024-29PL-XX 100 125 GD-1024-60PL-XX GD-1024-39PL-XX GD-1028-23PL-XX 200 260 GDU-1028-30PL-XX GDU-1028-31PL-XX GDT-1028-42PL-XX 2 30 32 GD-1016-51PL-TC GD-1016-23PL-TC GD-1020-36PL-TC 60 63 GD-1020-61PL-TC GD-1020-40PL-TC GD-1024-29PL-TC 100 125 GD-1024-60PL-TC GD-1024-39PL-TC GD-1028-23PL-TC 200 260 GDU-1028-30PL-TC GDU-1028-31PL-TC GDT-1028-42PL-TC 2 30 32 GD-B1716-51SL-FH GD-B1716-23SL- FH GD-B1720-36SL- FH 60 63 GD-B1720-61SL- FH GD-B1720-40SL- FH GD-B1724-29SL-BK 100 125 GD-B1724-60SL-BK GD-B1724-39SL-BK GD-B1728-23SL-BL 200 260 GDU-B1728-30SL-BL GDU-B1728-31SL-BL GDT-B1728-42SL-BL2 30 32 GD-B1916-51SL-2 GD-B1916-23SL-2 GD-B1920-36SL-2 60 63 GD-B1920-61SL-2 GD-B1920-40SL-2 GD-B1924-29SL-2 100 125 GD-B1924-60SL-2 GD-B1924-39SL-2 GD-B1928-23SL-2 200 260 GDU-B1928-30SL-2 GDU-B1928-31SL-2 GDT-B1928-42SL-2 2 30 32 GD-B1716-51SL- GD-B1716-23SL- GD-B1720-36SL- 60 63 GD-B1720-61SL- GD-B1720-40SL- GD-B1724-29SL- 100 125 GD-B1724-60SL- GD-B1724-39SL- GD-B1728-23SL- 200 260 GDU-B1728-30SL- GDU-B1728-31SL- GDT-B1728-42SL- 30 32 GD-B1516-51SL-XX GD-B1516-23SL-XX GD-B1520-36SL-XX 60 63 GD-B1520-61SL-XX GD-B1520-40SL-XX GD-B1524-29SL-XX 100 125 GD-B1524-60SL-XX GD-B1524-39SL-XX GD-B1528-23SL-XX 200 260 GDU-B1528-30SL-XX GDU-B1528-31SL-XX GDT-B1528-42SL-XX 2 30 32 GD-B1516-51SL-TC GD-B1516-23SL-TC GD-B1520-36SL-TC 60 63 GD-B1520-61SL-TC GD-B1520-40SL-TC GD-B1524-29SL-TC 100 125 GD-B1524-60SL-TC GD-B1524-39SL-TC GD-B1528-23SL-TC 200 260 GDU-B1528-30SL-TC GDU-B1528-31SL-TC GDT-B1528-42SL-TC 2 Covers are standard with all receptacles. For plugs add “D”. EX: GD-D1016 2 This is a 3 pole 4 wire + 2 relay insert. 3 Designed to thread into NPT opening. Shell Size 16 (EX: GD-B1916) into 1.5” NPT, 20 into 2.0”, 24 into 2.5” and 28 into 3.0” 4 Designed to accept NPT conduit. Shell Size 16 (EX: GD-D1016) into 1.25” NPT, 20 into 1.5”, 24 into 2.0” and 28 into 2.5” 5 Designed to accept NPT conduit. Shell Size 16 (EX: GD-B1516) into 1.25” NPT, 20 into 1.5”, 24 into 2.0” and 28 into 2.5” XX 2 Replace with cable diameter code number from Page 37. Replace with pigtail length code. EX: L36 calls for 36” pigtails. Standard is 36”. 2 Replace with pigtail length code. EX: L48 calls for 48” pigtails. Standard is 48”. See Pages 42 and 43 for Part Number Code Logic. Page 11 AMPERES Plug, Attachment 1 Plug, NPT 1,3 Receptacle, Junction Box Receptacle, NPT 2 Receptacle, Panel Mount Receptacle, Attachment Receptacle, NPT 4 2 POLE, 3 WIRE 3 POLE, 4 WIRE 4 POLE, 5 WIRE 30 32 GB-1016-51PL-XX GB-1016-23PL-XX GB-1020-36PL-XX 60 63 GB-1020-61PL-XX GB-1020-40PL-XX GB-1024-29PL-XX GB-1028-23PL-XX 100 125 GB-1024-60PL-XX GB-1024-39PL-XX - 260 GB-1028-30PL-XX GB-1028-31PL-XX 30 32 GB-1016-51PL-TC GB-1016-23PL-TC GB-1020-36PL-TC 60 63 GB-1020-61PL-TC GB-1020-40PL-TC GB-1024-29PL-TC 100 125 GB-1024-60PL-TC GB-1024-39PL-TC GB-1028-23PL-TC - 260 GB-1028-30PL-TC GB-1028-31PL-TC 30 32 GB-B1716-51SL-FH GB-B1716-23SL- FH GB-B1720-36SL- FH 60 63 GB-B1720-61SL- FH GB-B1720-40SL- FH GB-B1724-29SL-BK 100 125 GB-B1724-60SL-BK GB-B1724-39SL-BK GB-B1728-23SL-BL - 260 GB-B1728-30SL-BL GB-B1728-31SL-BL 30 32 GB-B1916-51SL-2 GB-B1916-23SL-2 GB-B1920-36SL-2 60 63 GB-B1920-61SL-2 GB-B1920-40SL-2 GB-B1924-29SL-2 100 125 GB-B1924-60SL-2 GB-B1924-39SL-2 GB-B1928-23SL-2 - 260 GB-B1928-30SL-2 GB-B1928-31SL-2 30 32 GB-B1716-51SL- GB-B1716-23SL- GB-B1720-36SL- 60 63 GB-B1720-61SL- GB-B1720-40SL- GB-B1724-29SL- 100 125 GB-B1724-60SL- GB-B1724-39SL- GB-B1728-23SL- - 260 GB-B1728-30SL- GB-B1728-31SL- 30 32 GB-B1516-51SL-XX GB-B1516-23SL-XX GB-B1520-36SL-XX 60 63 GB-B1520-61SL-XX GB-B1520-40SL-XX GB-B1524-29SL-XX 100 125 GB-B1524-60SL-XX GB-B1524-39SL-XX GB-B1528-23SL-XX - 260 GB-B1528-30SL-XX GB-B1528-31SL-XX 30 60 32 63 GB-B1516-51SL-TC GB-B1520-61SL-TC GB-B1516-23SL-TC GB-B1520-40SL-TC GB-B1520-36SL-TC GB-B1524-29SL-TC 100 - 125 260 GB-B1524-60SL-TC GB-B1528-30SL-TC GB-B1524-39SL-TC GB-B1528-31SL-TC GB-B1528-23SL-TC 1 Covers are standard with all receptacles. For plugs add “D”. EX: GB-D1016 2 Designed to thread into NPT opening. Shell Size 16 (EX: GB-B1916) into1.5” NPT, 20 into 2.0”, 24 into 2.5” and 28 into 3.0” 3 Designed to accept NPT conduit. Shell Size 16 (EX: GB-D1016) into 1.25” NPT, 20 into 1.5”, 24 into 2.0” and 28 into 2.5” 4 XX Designed to accept NPT conduit. Shell Size 16 (EX: GB-B1516) into 1.25” NPT, 20 into 1.5”, 24 into 2.0” and 28 into 2.5” Replace with cable diameter code number from Page 37. Replace with pigtail length code. EX: L36 calls for 36” pigtails. Standard is 36”. 2 Replace with pigtail length code. EX: L48 calls for 48” pigtails. Standard is 48”. See Pages 42 and 42 for Part Number Code Logic. Page 12 Plug, Attachment Receptacle, Junction Box Receptacle, NPT 3 Receptacle, Panel Mount Receptacle, Attachment AMPERES 2 POLE, 3 WIRE 3 POLE, 4 WIRE 4 POLE, 5 WIRE 30 BM-D1016-51PL-XX BM-D1016-23PL-XX BM-D1020-36PL-XX 60 BM-D1020-61PL-XX BM-D1020-40PL-XX BM-D1024-29PL-XX 100 BM-D1024-60PL-XX BM-D1024-39PL-XX BM-D1028-23PL-XX 200 BM-D1028-30PL-XX BM-D1028-31PL-XX BM-D1028-42PL-XX 2 30 BM-B1716-51SL- FH BM-B1716-23SL- FH BM-B1720-36SL- FH 60 BM-B1720-61SL- FH BM-B1720-40SL- FH BM-B1724-29SL-BK 100 BM-B1724-60SL-BK BM-B1724-39SL-BK BM-B1728-23SL-BL 200 BM-B1728-30SL-BL BM-B1728-31SL-BL BM-B1728-42SL-BL2 30 BM-B1916-51SL- BM-B1916-23SL- BM-B1920-36SL- 60 BM-B1920-61SL- BM-B1920-40SL- BM-B1924-29SL- 100 BM-B1924-60SL- BM-B1924-39SL- BM-B1928-23SL- 200 BM-B1928-30SL- BM-B1928-31SL- BM-B1928-42SL- 2 30 BM-B1716-51SL- BM-B1716-23SL- BM-B1720-36SL- 60 BM-B1720-61SL- BM-B1720-40SL- BM-B1724-29SL- 100 BM-B1724-60SL- BM-B1724-39SL- BM-B1728-23SL- 200 BM-B1728-30SL- BM-B1728-31SL- BM-B1728-42SL- 2 30 BM-B1516-51SL-XX BM-B1516-23SL-XX BM-B1520-36SL-XX 60 BM-B1520-61SL-XX BM-B1520-40SL-XX BM-B1524-29SL-XX 100 BM-B1524-60SL-XX BM-B1524-39SL-XX BM-B1528-23SL-XX 200 BM-B1528-30SL-XX BM-B1528-31SL-XX BM-B1528-42SL-XX 2 1 Covers are standard with all receptacles. For plugs add “D”. EX: BM-D1016 2 This is a 3 pole 4 wire + 2 relay contact insert. 3 XX Designed to thread into NPT opening. Shell Size 16 (EX: BM-B1916) into 1.5” NPT, 20 into 2.0”, 24 into 2.5” and 28 into 3.0” Replace with cable diameter code number from page 37. Replace with pigtail length code. EX: L36 calls for 36” pigtails. Standard is 36”. See Pages 42 and 43 for Part Number Code Logic. Consult factory for control configurations of the BM connector. Page 13 Vantage Technology, the premier manufacturer of Third Party Certified explosionproof plugs and sockets, is proud to present the AF series of control connectors. Applying shell hardware from our UL and CSA listed power connectors, the AF is designed for control applications with inserts using #12, #16 and #18 AWG contacts. CSA MSHA ATEX CSA International Mine Safety - U.S. Bureau of Mines EC Type-Examination Certificate with KEMA (See page 26-27 for ATEX details.) Stemming from a U.S. Navy project, Vantage StarLine connectors were expanded to include control inserts for use in hazardous areas. In a landmark achievement, the AF Series was Listed by Factory Mutual for use in Class I, Division 1, Groups C-D areas. Then MSHA, previously known as the U.S. Bureau of Mines, certified this connector as an extension of the BM series for use in coal mining environments. Present listings and features include: Control Inserts Multi-pin inserts can be specified for either crimp or solder termination with contacts whose size and amp ratings are as follows: Pin - Socket #12 AWG / 4.0 mm2 #16 AWG / 1.5 mm2 #18 AWG / .75 mm2 Insert Patterns With 15 plus inserts having 10 thru 100 contacts the AF Explosionproof StarLine stands alone as a Class I, Division 1 control connector. Inserts with the highest contact density per shell size are: Amps 10 6.5 3.5 20 15 10 Shell 16 Shell 20 Shell 24 61 - #18 AWG contacts 90 - #18 AWG contacts 100 - #16 AWG contacts Circuit Breaking AF StarLine CSA and MSHA listed connectors are circuit breaking, designed and tested to make/break at full rated load – an added safety feature. Corrosion Resistance Designed for corrosive environments, junction boxes are sand cast, copper-free aluminum, protected by our VanGuard baked polymer finish system. Plug and receptacle shells are machined from 6061T6 aluminum and finished by hard anodizing to exceed corrosion resistance requirements per MIL-STD 202, Method 101, Condition D. Submersible AF connectors are explosionproof and submersible! Fully mated, they will withstand 200 PSI external and 100 PSI internal pressure. Reverse Service Available with all Victory and Millennium series connectors, reverse service provides electrical safety where lineside power is carried from the plug to a receptacle. Factory Sealing Junction box, NPT and panel-mount receptacles are pre-wired and factory sealed. No external seals or fittings are required. Voltage AF Explosionproof StarLine has been tested for service through 250 VAC / 125 VDC circuit breaking; select inserts are rated 480 VAC non-circuit breaking. See pages 16-17 for options. BM Control Connectors Vantage offers MSHA certified XP connectors for instrumentation and control, tested for use in coal dust and methane atmospheres. Consult factory for options. Purged / Pressurized Systems Victory and Millennium series NPT / panel mount receptacles, with factory sealing and flat gaskets are ideal for this technology. Page 14 NPT Mount Vantage developed NPT receptacles to thread into explosionproof enclosures. Prewired and factory sealed, these receptacles are available in the following shell sizes with wire leads of any specified length. Shell Size 16 Shell Size 20 Shell Size 24 Shell Size 28 Panel Mount AF panel mount receptacles with flat gasket are pre-wired and factory sealed with pigtails of any specified length. First used on NEMA enclosures in Division 2 environments, their use expanded into Division 1 purged / pressurized systems. To date the AF stands alone as the only Division 1 control connector. 1½" NPT 2" NPT 2½" NPT 3" NPT Attachment Receptacles Sometimes called in-line or cable-mounted, they are available with backshell variations and watertight threaded covers. With this design, assemblies can be built in “extension cord” fashion. Cable Assemblies Complete cable assemblies and receptacle distribution boxes are available incorporating Vantage Technology connectors. Please contact us regarding specification options. Electrical Interlock Switch Receptacles with junction boxes are available with this variation. The normally open switch is operated automatically by engagement/separation of the mating plug. Reference Motor Minder XP Connectors on page 10. Color Coding Plugs and receptacles are available with color coding variations for specific application identification. This coding could include the plug coupling nut and cover with matching colors on various receptacle components. Alternate Keying For added safety, inserts can be keyed in alternate positions to prevent mating of different voltages, frequencies or services. See pages 29-36 for insert configurations. KEY N 02 03 04 05 POSITION 0° 48° 144° 252° 276° See Pages 16-17 for AF Part Numbers See Pages 44-45 for AF Part Number Code Logic See Pages 39-41 for AF Product Dimensions Page 15 AMPS @ 250 VAC 4 Plug, 2 Attachment Plug, Conduit Receptacle, Junction Box 2, 3 1 Pin Quantity Pin Size AWG (mm2) 10 #12 (4.0) 10.0 20 AF-1016-681PL-XX AF-1016-681PL-TC AF-B1716-681SL-FH 10 #12 G (4.0) 10.0 20 AF-1016-676PL-XX AF-1016-676PL-TC AF-B1716-676SL- FH 19 #12 G (4.0) 10.0 20 AF-1016-612PL-XX AF-1016-612PL-TC AF-B1716-612SL- FH 19 #12 (4.0) 10.0 20 AF-1016-677PL-XX AF-1016-677PL-TC AF-B1716-677SL- FH 19 #12 (4.0) 10.0 4 20 AF-1020-676PL-XX AF-1020-676PL-TC AF-B1720-676SL- FH 19 #12 G (4.0) 10.0 4 20 AF-1020-688PL-XX AF-1020-688PL-TC AF-B1720-688SL- FH 19 #16 (1.5) 6.5 15 AF-1016-655PL-XX AF-1016-655PL-TC AF-B1716-655SL- FH 20 #12 (4.0) 10.0 20 AF-1020-632PL-XX AF-1020-632PL-TC AF-B1720-632SL- FH 20 #12 G (4.0) 10.0 20 AF-1020-687PL-XX AF-1020-687PL-TC AF-B1720-687SL- FH 37 #12 (4.0) 10.0 20 AF-1020-686PL-XX AF-1020-686PL-TC AF-B1720-686SL- FH 37 #12 G (4.0) 10.0 20 AF-1020-650PL-XX AF-1020-650PL-TC AF-B1720-650SL- FH 37 #16 (1.5) 6.5 15 AF-1016-621PL-XX AF-1016-621PL-TC AF-B1716-621SL- FH 55 #18 (.75) 3.5 10 AF-1016-640PL-XX AF-1016-640PL-TC AF-B1716-640SL- FH 61 #18 (.75) 3.5 10 AF-1016-633PL-XX AF-1016-633PL-TC AF-B1716-633SL- FH 68 #16 (1.5) 6.5 15 AF-1020-613PL-XX AF-1020-613PL-TC AF-B1720-613SL- FH 100 #16 (1.5) 5.0 15 AF-1024-613PL-XX AF-1024-613PL-TC AF-B1724-613SL-BK 1 2 3 4 XX G = Insert includes one ground pin. Covers are standard with all receptacles. For plugs add “D”. EX: AF-D1016 Threads onto NPT conduit. Shell Size 16 (EX: AF-D1016) onto 1.25” NPT, 20 onto 1.5”, 24 onto 2.0” and 28 onto 2.5” Insert is also rated 480 VAC non-circuit breaking. Replace with cable diameter code number from Page 37. Replace with pigtail length code. EX: L36 calls for 36” pigtails. Standard is 36. See Pages 44 and 45 for Part Number Code Logic. Page 16 AMPS @ 250 VAC 3 Receptacle, NPT 2 Receptacle, Panel Mount Receptacle, Attachment 1 Pin Quantity Pin Size AWG (mm2) 10 #12 (4.0) 10.0 20 AF-B1916-681SL-2 AF-B1716-681SL- AF-B1516-681SL-XX 10 #12 G (4.0) 10.0 20 AF-B1916-676SL-2 AF-B1716-676SL- AF-B1516-676SL-XX 19 #12 G (4.0) 10.0 20 AF-B1916-612SL-2 AF-B1716-612SL- AF-B1516-612SL-XX 19 #12 (4.0) 10.0 20 AF-B1916-677SL-2 AF-B1716-677SL- AF-B1516-677SL-XX 19 #12 (4.0) 10.0 3 20 AF-B1920-676SL-2 AF-B1720-676SL- AF-B1520-676SL-XX 19 #12 G (4.0) 10.0 3 20 AF-B1920-688SL-2 AF-B1720-688SL- AF-B1520-688SL-XX 19 #16 (1.5) 6.5 15 AF-B1916-655SL-2 AF-B1716-655SL- AF-B1516-655SL-XX 20 #12 (4.0) 10.0 20 AF-B1920-632SL-2 AF-B1720-632SL- AF-B1520-632SL-XX 20 #12 G (4.0) 10.0 20 AF-B1920-687SL-2 AF-B1720-687SL- AF-B1520-687SL-XX 37 #12 (4.0) 10.0 20 AF-B1920-686SL-2 AF-B1720-686SL- AF-B1520-686SL-XX 37 #12 G (4.0) 10.0 20 AF-B1920-650SL-2 AF-B1720-650SL- AF-B1520-650SL-XX 37 #16 (1.5) 6.5 15 AF-B1916-621SL-2 AF-B1716-621SL- AF-B1516-621SL-XX 55 #18 (.75) 3.5 10 AF-B1916-640SL-2 AF-B1716-640SL- AF-B1516-640SL-XX 61 #18 (.75) 3.5 10 AF-B1916-633SL-2 AF-B1716-633SL- AF-B1516-633SL-XX 68 #16 (1.5) 6.5 15 AF-B1920-613SL-2 AF-B1720-613SL- AF-B1520-613SL-XX 100 #16 (1.5) 5.0 15 AF-B1924-613SL-2 AF-B1724-613SL- AF-B1524-613SL-XX 1 G = Insert includes one ground pin. 2 Threads into NPT opening. Shell Size 16 (EX: AF-B1916) into 1.5” NPT, 20 into 2.0”, 24 into 2.5” and 28 into 3.0” 3 Insert is also rated 480 VAC non-circuit breaking. XX Replace with cable diameter code number from Page 37. Replace with pigtail length code. EX: L36 calls for 36” pigtails. Standard is 36. 2 Replace with pigtail length code. EX: L48 calls for 48” pigtails. Standard is 48. See Pages 44 and 45 for Part Number Code Logic. Page 17 At the start of the third millennium, Vantage introduced the first stainless steel connectors designed for use in Class I and Class II hazardous areas. Incorporating all of the proven technology in the Victory Series, this landmark achievement includes CSA and ATEX listing on the following connectors. SD, SDU and SDT - Power. 30/32, 60/63, 100/125 and 200/260 amp with 3, 4, 5 and 6 pin inserts for Class I, Division 1 and Class II, Division 1, Groups B-C-D Divisional areas and EEx d IIC T6 IP 66/67 T 70°C Zonal areas. SF – Control. 10 thru 100 contacts, sizes 18 thru 12 AWG (0.75 – 4.0 mm2) Third Party Certification ... Vantage Millennium Series connectors have been tested and listed for use in hazardous areas by the following organizations: CSA International CSA ATEX EC Type-Examination Certificate with KEMA (See page 26-27 for ATEX details.) Power and Control Connector Styles Plug, Attachment Receptacle, Junction Box For use with cable or flexible conduit, with standard or Explosionproof sand-cast, copper-free aluminum enclosure reverse service inserts and environmental covers. protected by our VanGuard baked polymer finish system, for added corrosion resistance. Receptacle, Attachment For termination to cable or flexible conduit, with standard or reverse service inserts and environmental threaded covers. Receptacle, NPT Style Designed to thread into drilled and tapped openings in explosionproof enclosures, these receptacles are pre-wired and factory sealed with pigtails of any specified length. Plug, Tapped Conduit Attachment plugs and receptacles are available with backshell hardware for use with explosionproof, flexible conduit in Division 1 areas and Sealtite in Division 2. Receptacle, Panel-mount Designed to mount to a NEMA enclosure for use in Class I, Division 2 areas, these receptacles are pre-wired and factory sealed with pigtails of any length to meet your needs. Power and Control Features Corrosion Resistance Designed for corrosive environments, junction boxes are sand cast, copper-free aluminum, protected by our VanGuard baked polymer finish system. Plug and receptacle shells are machined from stainless steel, alloy 316. Submersible Vantage connectors are explosionproof and submersible! Fully mated, they will withstand 200 PSI of external as well as 100 PSI of internal pressure. Page 18 Control Connectors Multi-pin inserts can be crimp or solder terminated. Connectors have been tested for service through 250 VAC / 125 VDC. Select inserts are rated 480 VAC non-circuit breaking Color Coding Plugs and receptacles are available with color coding variations for specific application identification. This coding could include the plug coupling nut and cover with matching colors on various receptacle components. Cable Assemblies Connectors are available as complete assemblies made to your specification and shipped to any site, ready-toinstall. Control Inserts There are over 15 - with as few as 10 and as many as 100 contacts. Grounding and non-grounding types are available. Multi-pin inserts can be crimp or solder terminated. Inserts with the highest contact density per shell size are: Shell 16 Shell 20 Shell 24 61 - #18 AWG contacts 90 - #18 AWG contacts 100 - #16 AWG contacts Power Inserts 30/32, 60/63, 100/125 and 200/260 amp rated for service through 1000 VAC and designed for Class I and II Areas, per the U.S. and Canadian electrical codes and Zone 1 Areas per the ATEX Directive. Shell 16,20,24,28 Shell 16,20,24,28 Shell 16,20,24,28 Shell 28 2 Pole 3 Wire 3 Pole 4 Wire 4 Pole 5 Wire 3 Pole 4 Wire + 2 Relays Circuit-Breaking CSA lists the Millennium Series to make/break at full rated load. These connectors were required to pass an overload test of 50 cycles at 150% of their ampere rating in a chamber filled with a mixture of hazardous vapors. ATEX listings certify a higher amperage rating because in the CENELEC scheme circuits are not to be made or broken under load. Amps Pin – Socket Wire Size 12 AWG (4.0 mm2) 16 AWG (1.5 mm2) 18 AWG (.75 mm2) 10 6.5 3.5 20 15 10 Amps Pin – Socket Wire Size 8 AWG / (10 mm2) 4 AWG / (25 mm2) 1/0 AWG / (55 mm2) 4/0 (120 mm2) 30 60 100 200 32 63 125 260 Voltage Control connectors tested for service through 250 VAC / 125 VDC, select inserts through 480 VAC non-circuit breaking Power connectors have been tested for service through 600 VAC (CSA) & 1000 VAC / 500 VDC (KEMA) Alternate Keyed Inserts For added safety, inserts can be keyed in alternate positions to prevent mating of differing voltages, frequencies or services. KEY N 01 02 03 04 KEY N 01 02 03 04 05 POSITION 0° 75° 105° 150° 232° POSITION 0° 105° 120° 315° 330° 345° Frequency Tested at both 60 and 400 hertz. This feature is of paramount importance at airports and aircraft maintenance facilities around the world. Users include Boeing, Lockheed Martin, McDonnell Douglas, United, TWA, Delta, Air Canada, El Al and the C5A Military Program. Contact Plating Options Control contact plating options include: silver, gold over silver and gold over nickel. Thermocouple contacts are also available. Reverse Service This feature, available with all connectors, ensures electrical safety where lineside power is carried from the plug to a receptacle. Factory Sealing Junction box, NPT and panel-mounted receptacles are pre-wired and factory sealed. No external seals are required. See pages: 20-23 for Part Numbers 42-45 for Part Number Code Logic 39-41 for Product Dimensions Page 19 AMPERES Plug, Attachment 1 Receptacle, Junction Box Receptacle, NPT 3 Receptacle, Panel Mount Receptacle, Attachment 2 POLE, 3 WIRE 3 POLE, 4 WIRE 4 POLE, 5 WIRE 30 32 SD-1016-51PL-XX SD-1016-23PL-XX SD-1020-36PL-XX 60 63 SD-1020-61PL-XX SD-1020-40PL-XX SD-1024-29PL-XX 100 125 SD-1024-60PL-XX SD-1024-39PL-XX SD-1028-23PL-XX 200 260 SDU-1028-30PL-XX SDU-1028-31PL-XX SDT-1028-42PL-XX 2 30 32 SD-B1716-51SL-FH SD-B1716-23SL- FH SD-B1720-36SL- FH 60 63 SD-B1720-61SL- FH SD-B1720-40SL- FH SD-B1724-29SL-BK 100 125 SD-B1724-60SL-BK SD-B1724-39SL-BK SD-B1728-23SL-BL 200 260 SDU-B1728-30SL-BL SDU-B1728-31SL-BL SDT-B1728-42SL-BL2 30 32 SD-B1916-51SL-2 SD-B1916-23SL-2 SD-B1920-36SL-2 60 63 SD-B1920-61SL-2 SD-B1920-40SL-2 SD-B1924-29SL-2 100 125 SD-B1924-60SL-2 SD-B1924-39SL-2 SD-B1928-23SL-2 200 260 SDU-B1928-30SL-2 SDU-B1928-31SL-2 SDT-B1928-42SL-2 2 30 32 SD-B1716-51SL- SD-B1716-23SL- SD-B1720-36SL- 60 63 SD-B1720-61SL- SD-B1720-40SL- SD-B1724-29SL- 100 125 SD-B1724-60SL- SD-B1724-39SL- SD-B1728-23SL- 200 260 SDU-B1728-30SL- SDU-B1728-31SL- SDT-B1728-42SL- 2 30 32 SD-B1516-51SL-XX SD-B1516-23SL-XX SD-B1520-36SL-XX 60 63 SD-B1520-61SL-XX SD-B1520-40SL-XX SD-B1524-29SL-XX 100 125 SD-B1524-60SL-XX SD-B1524-39SL-XX SD-B1528-23SL-XX 200 260 SDU-B1528-30SL-XX SDU-B1528-31SL-XX SDT-B1528-42SL-XX 2 1 Covers are standard with all receptacles. For plugs add “D”. EX: SD-D1016 2 This is a 3 pole 4 wire + 2 relay contact insert. 3 XX Designed to thread into NPT opening. Shell Size 16 (EX: SD-B1916) into 1.5” NPT, 20 into 2.0”, 24 into 2.5” and 28 into 3.0” Replace with cable diameter code number from Page 37. Replace with pigtail length code. EX: L36 calls for 36” pigtails. Standard is 36”. 2 Replace with pigtail length code. EX: L48 calls for 48” pigtails. Standard is 48”. See Pages 42 and 43 for Part Number Code Logic. Page 20 AMPERES Plug, Attachment 1 Receptacle, Junction Box Receptacle, NPT 2 Receptacle, Panel Mount Receptacle, Attachment 1 2 XX 2 POLE, 3 WIRE 3 POLE, 4 WIRE 4 POLE, 5 WIRE 30 32 SB-1016-51PL-XX SB-1016-23PL-XX SB-1020-36PL-XX 60 63 SB-1020-61PL-XX SB-1020-40PL-XX SB-1024-29PL-XX 100 125 SB-1024-60PL-XX SB-1024-39PL-XX SB-1028-23PL-XX - 260 SBU-1028-30PL-XX SBU-1028-31PL-XX 30 32 SB-B1716-51SL- FH SB-B1716-23SL- FH SB-B1720-36SL- FH 60 63 SB-B1720-61SL- FH SB-B1720-40SL- FH SB-B1724-29SL-BK 100 125 SB-B1724-60SL-BK SB-B1724-39SL-BK SB-B1728-23SL-BL - 260 SBU-B1728-30SL-BL SBU-B1728-31SL-BL 30 32 SB-B1916-51SL-2 SB-B1916-23SL-2 SB-B1920-36SL-2 60 63 SB-B1920-61SL-2 SB-B1920-40SL-2 SB-B1924-29SL-2 100 125 SB-B1924-60SL-2 SB-B1924-39SL-2 SB-B1928-23SL-2 - 260 SBU-B1928-30SL-2 SBU-B1928-31SL-2 30 32 SB-B1716-51SL- SB-B1716-23SL- SB-B1720-36SL- 60 63 SB-B1720-61SL- SB-B1720-40SL- SB-B1724-29SL- 100 125 SB-B1724-60SL- SB-B1724-39SL- SB-B1728-23SL- - 260 SBU-B1728-30SL- SBU-B1728-31SL- 30 32 SB-B1516-51SL-XX SB-B1516-23SL-XX SB-B1520-36SL-XX 60 63 SB-B1520-61SL-XX SB-B1520-40SL-XX SB-B1524-29SL-XX 100 125 SB-B1524-60SL-XX SB-B1524-39SL-XX SB-B1528-23SL-XX - 260 SBU-B1528-30SL-XX SBU-B1528-31SL-XX Covers are standard with all receptacles. For plugs add “D”. EX: SB-D1016 Designed to thread into NPT opening. Shell Size 16 (EX: SB-B1916) into 1.5” NPT, 20 into 2.0”, 24 into 2.5” and 28 into 3.0” Replace with cable diameter code number from Page 37. Replace with pigtail length code. EX: L36 calls for 36” pigtails. Standard is 36”. 2 Replace with pigtail length code. EX: L48 calls for 48” pigtails. Standard is 48”. See Pages 42 and 43 for Part Number Code Logic. Page 21 AMPS @ 250 VAC 4 Plug, 2 Attachment Plug, Conduit Receptacle, Junction Box 2, 3 1 Pin Quantity Pin Size AWG (mm2) 10 #12 (4.0) 10.0 20 SF-1016-681PL-XX SF-1016-681PL-TC SF-B1716-681SL-FH 10 #12 G (4.0) 10.0 20 SF-1016-676PL-XX SF-1016-676PL-TC SF-B1716-676SL- FH 19 #12 G (4.0) 10.0 20 SF-1016-612PL-XX SF-1016-612PL-TC SF-B1716-612SL- FH 19 #12 (4.0) 10.0 20 SF-1016-677PL-XX SF-1016-677PL-TC SF-B1716-677SL- FH 19 #12 (4.0) 10.0 4 20 SF-1020-676PL-XX SF-1020-676PL-TC SF-B1720-676SL- FH 19 #12 G (4.0) 10.0 4 20 SF-1020-688PL-XX SF-1020-688PL-TC SF-B1720-688SL- FH 19 #16 (1.5) 6.5 15 SF-1016-655PL-XX SF-1016-655PL-TC SF-B1716-655SL- FH 20 #12 (4.0) 10.0 20 SF-1020-632PL-XX SF-1020-632PL-TC SF-B1720-632SL- FH 20 #12 G (4.0) 10.0 20 SF-1020-687PL-XX SF-1020-687PL-TC SF-B1720-687SL- FH 37 #12 (4.0) 10.0 20 SF-1020-686PL-XX SF-1020-686PL-TC SF-B1720-686SL- FH 37 #12 G (4.0) 10.0 20 SF-1020-650PL-XX SF-1020-650PL-TC SF-B1720-650SL- FH 37 #16 (1.5) 6.5 15 SF-1016-621PL-XX SF-1016-621PL-TC SF-B1716-621SL- FH 55 #18 (.75) 3.5 10 SF-1016-640PL-XX SF-1016-640PL-TC SF-B1716-640SL- FH 61 #18 (.75) 3.5 10 SF-1016-633PL-XX SF-1016-633PL-TC SF-B1716-633SL- FH 68 #16 (1.5) 6.5 15 SF-1020-613PL-XX SF-1020-613PL-TC SF-B1720-613SL- FH 100 #16 (1.5) 5.0 15 SF-1024-613PL-XX SF-1024-613PL-TC SF-B1724-613SL-BK 1 G = Insert includes one ground pin. 2 Covers are standard with all receptacles. For plugs add “D”. EX: SF-D1016 3 Threads onto NPT conduit. Shell Size 16 (EX: SF-D1016) onto 1.25” NPT, 20 onto 1.5”, 24 onto 2.0” and 28 onto 2.5” 4 Insert is also rated 480 VAC non-circuit breaking. XX Replace with cable diameter code number from Page 37. See Pages 44 and 45 for Part Number Code Logic. Page 22 AMPS @ 250 VAC 3 Receptacle, NPT 2 Receptacle, Panel Mount Receptacle, Attachment 1 Pin Quantity Pin Size AWG (mm2) 10 #12 (4.0) 10.0 20 SF-B1916-681SL-2 SF-B1716-681SL- SF-B1516-681SL-XX 10 #12 G (4.0) 10.0 20 SF-B1916-676SL-2 SF-B1716-676SL- SF-B1516-676SL-XX 19 #12 G (4.0) 10.0 20 SF-B1916-612SL-2 SF-B1716-612SL- SF-B1516-612SL-XX 19 #12 (4.0) 10.0 20 SF-B1916-677SL-2 SF-B1716-677SL- SF-B1516-677SL-XX 19 #12 (4.0) 10.0 3 20 SF-B1920-676SL-2 SF-B1720-676SL- SF-B1520-676SL-XX 19 #12 G (4.0) 10.0 3 20 SF-B1920-688SL-2 SF-B1720-688SL- SF-B1520-688SL-XX 19 #16 (1.5) 6.5 15 SF-B1916-655SL-2 SF-B1716-655SL- SF-B1516-655SL-XX 20 #12 (4.0) 10.0 20 SF-B1920-632SL-2 SF-B1720-632SL- SF-B1520-632SL-XX 20 #12 G (4.0) 10.0 20 SF-B1920-687SL-2 SF-B1720-687SL- SF-B1520-687SL-XX 37 #12 (4.0) 10.0 20 SF-B1920-686SL-2 SF-B1720-686SL- SF-B1520-686SL-XX 37 #12 G (4.0) 10.0 20 SF-B1920-650SL-2 SF-B1720-650SL- SF-B1520-650SL-XX 37 #16 (1.5) 6.5 15 SF-B1916-621SL-2 SF-B1716-621SL- SF-B1516-621SL-XX 55 #18 (.75) 3.5 10 SF-B1916-640SL-2 SF-B1716-640SL- SF-B1516-640SL-XX 61 #18 (.75) 3.5 10 SF-B1916-633SL-2 SF-B1716-633SL- SF-B1516-633SL-XX 68 #16 (1.5) 6.5 15 SF-B1920-613SL-2 SF-B1720-613SL- SF-B1520-613SL-XX 100 #16 (1.5) 5.0 15 SF-B1924-613SL-2 SF-B1724-613SL- SF-B1524-613SL-XX 1 G = Insert includes one ground pin. 2 Threads into NPT opening. Shell Size 16 (EX: SF-B1916) into 1.5” NPT, 20 into 2.0”, 24 into 2.5” and 28 into 3.0” 3 Insert is also rated 480 VAC non-circuit breaking. XX Replace with cable diameter code number from Page 37. Replace with pigtail length code. EX: L36 calls for 36” pigtails. Standard is 36. 2 Replace with pigtail length code. EX: L48 calls for 48” pigtails. Standard is 48. See Pages 44 and 45 for Part Number Code Logic. Page 23 Ground Power Receptacles Vantage ground power receptacles are designed to mount flush to the concrete floor of a hangar deck. They are available with single or dual receptacles, as well as push button switches and indicator lights for point-of-use control. Color coded covers, receptacle options, and conduit entries are among the many variations available to the user. Vantage Ground Power connectors meet the world’s most stringent certification requirements. First tested and listed by Underwriters Laboratories, these ground power units are now also approved and certified to Class I, Division 1, Groups C & D at 60/400 hertz by CSA International - Canada and ATEX certified EEx d IIB + H2 T6 by KEMA - The Netherlands. See page 25 for part numbers and pages 46 and 47 for code logic. Single receptacle shown. Available as duplex or with pilot light and pushbutton station. Aircraft Connectors – GDT Series The GDT Series is the explosionproof companion of the MS25486 auxiliary power connector, the 400 hertz aircraft power standard throughout the world. With GDT, disconnects can be established in hazardous locations on hanger floors and walls. GDT connectors were first incorporated into aircraft hangar facilities with the introduction of large commercial / military aircraft in the late sixties. The U.S. Air Force, after months of competition, selected the GD Series as the electrical connector standard for all C5A hangar facilities throughout the world. The Boeing Company followed selecting the GDU as part of their 747 assembly facility. Ground Power Receptacles, shown above, are UL and CSA Listed in single and duplex styles that mount flush into an aircraft hangar floor or apron. Frequency In a landmark achievement these receptacles are Division 1 and Zone 1 certified at 50, 60 and 400 hertz. Drainage A unique drainage feature has two large 2” threaded holes located at opposite sides of the power box upper skirt. Use of these holes allows water that might pool on the receptacle to flow through the drainage conduits. Junction Box GDT-B1728-42SL-BL for Division 1 areas. Receptacles are pre-wired and factory sealed, external seals are not required. Junction box has a 3" NPT conduit opening on the bottom for bulkhead or service pit mounting. Division 2 Panel Mount Receptacle with enclosure Interlocked Receptacle V-70017-XX-200A. 200 amp interlocked connector available with contactor (RC) or circuit breaker (RB) with shunt trip. Designed to be mounted to a bulkhead / wall, this enclosure is supplied complete and ready to install. Panel Mount Receptacle GDT-B1728-42SL-L36. Pre-wired and factory sealed, these receptacles are designed for NEMA style enclosures in Division 2 areas. Pigtails (L36) can be any length. Example: L36 calls for 3 foot (36") pigtails. NPT Mount GDT-B1928-42SL-L48. Pre-wired and factory sealed, these receptacles thread into an NPT conduit opening on an explosionproof junction box for use in Division 1 areas. Pigtails (L48) can be any length. Example: L48 calls for 4 foot (48") pigtails. Attachment Receptacle GDT-B1528-42SL-XX Receptacles, which can be mounted to flexible cables, allow assemblies to be built in “extension cord” fashion for use in hazardous areas. Delta Airlines at Hartsfield International Airport chose to use these attachment receptacles with large power operated reels mounted in the hangar ceiling. Controlled by conveniently located pushbutton stations, these receptacles can be lowered to the hangar floor thereby eliminating excess cable in the workplace. Page 24 Overhead Attachment Receptacle SINGLE RECEPTACLE GDS - D5L1 - 92ANMEQP Of the many available variations we selected above example: GD = Class I, Division 1,Groups C-D; S = Red/Amber pilot lights and on/off switches; D5L1 = 200/260 amp, 5P 6W, 60/400 hertz keyed in the 01 position; 92 = single; ANM = Side A - 3.0" and 2.5"; EQP = Side E – 4.0" and 3.5". GROUND POWER COVER For additional part numbers see Single code logic on page 46. Mating plugs are listed on page 43. DUPLEX RECEPTACLE GD - A1B3 - 93B68DMN PILOT LIGHT RED/GREEN There are hundreds of variations and we selected the above example: GD = Class I, Division 1, Groups C-D; A1 = 30/32 amp, 2P 3W, 60/400 hertz; B3 = 60/63 amp, 3P 4W, 60/400 hertz; 93 = duplex; B68 = Side B - 1.0" and 1.5"; DMN = Side D - 2.5" and 3.0". PUSHBUTTON STATION For additional part numbers see Duplex code logic on page 47. Mating plugs are listed on page 43. INTERMEDIATE COVER AMPS Insert 600/1000 VAC, 60/400 Hz 2 Pole 3 Wire RECEPTACLE 30 POWER BOX 60 SINGLE 100 32 63 125 2X RECEPTACLE INTERMEDIATE COVER 200 260 Insert Symbol Receptacle Assembly A1 GD-1716-51SL-L36 A2 GD-1716-23SL-L36 3 Pole 4 Wire 4 Pole 5 Wire B1 GD-1720-36SL-L36 2 Pole 3 Wire B2 GD-1720-61SL-L36 3 Pole 4 Wire B3 GD-1720-40SL-L36 4 Pole 5 Wire C1 GD-1724-29SL-L36 2 Pole 3 Wire C2 GD-1724-60SL-L36 3 Pole 4 Wire C3 GD-1724-39SL-L36 4 Pole 5 Wire D1 GD-1728-23SL-L36 2 Pole 3 Wire D3 GD-1728-30SL-L36 3 Pole 4 Wire D4 GDU-1728-31SL-L36 5 Pole 6 Wire D5 GDT-1728-42SL-L36 See pages 46 and 47 for part number code logic and conduit size and location options. 4" MAX CONDUIT SIZE POWER BOX SIDE "D" SIDE "A" USE LETTER O IF BOTTOM NPT OPENING OMITTED. EXAMPLE AOM. SIDE "C" SIDE "B" DUPLEX BOTTOM VIEW SIDE VIEW MAX DIA OF SECOND CONDUIT TAP IN SIDE WALL IS 2 1/2" Page 25 Vantage StarLine connectors carry ATEX certification. Conformance to both IEC/CENELEC and NEC standards assure you of protection no matter what installation regulations are required. Look for the Ex epsilon logo throughout this catalog to guide you to the right StarLine product for your application. Certificates Product Quality Assurance Notification EC-Type Examination Equipment or Components intended for use in potentially explosive atmospheres. Directive 94/9/EC. Notification Number: DNV-OSL-ATEX-2571Q Equipment or Components intended for use in potentially explosive atmospheres. Directive 94/9/EC. Certificate Number: KEMA 04ATEX2179 X Equipment Marking Receptacles and Plugs Series GB, GD, GDT, GDU Series SB, SD, SDT, SDU Series AF Series SF Series EMR Single and Duplex Ground Power Receptacles Electrical Ratings GB, GD, GDT, GDU SB, SD, SDT, SDU AF SF EMR Single and Duplex Ground Power Receptacles Attachment Connectors Page 26 Wire Size mm2 AWG 0.75 18 AMP Rating Voltage Rating AC / DC Available Configurations (See pages 29 – 36) 10 250 / 125 55 to 61 Contacts 1.5 16 15 250 / 125 19 to 100 Contacts 4 12 20 250 / 125 10 to 37 Contacts 10 8 32 1000 / 500 2P3W, 3P4W, 4P5W 25 4 63 1000 / 500 2P3W, 3P4W, 4P5W 55 1/0 125 1000 / 500 2P3W, 3P4W, 4P5W 2P3W, 3P4W, 4P5W 120 4/0 260 1000 / 500 3P4W + 2 Relays ATEX amp ratings are calculated under a non circuit breaking scenario. Do not make or break connectors under load. Enclosure Mount Receptacles Vantage EMR Series packages our EEx power and control receptacle(s) into EEx e certified enclosures. Our receptacles are factory mounted to properly sized EEx e enclosures and the wire leads landed to EEx e terminals. Receptacles are available with straight or angled mounting. Gland openings and glands can be provided on request. Other options include control buttons (including: push, selector switch, mushroom push, stop, and key switch), pilot lights and zener barriers. Consult our sales group with your requirements. Factory Terminated Our full range of power and control receptacles are available with the EMR Series. Pages 29-36 depict the insert patterns you can choose from. Specify Victory standard hard coated aluminum or Millennium stainless steel shells; enclosure material is to your specification. Junction Box Receptacles When our receptacles are mounted to Vantage flameproof junction boxes, power and control is available in a compact EEx d package. Designed for corrosive environments, junction boxes are sand cast, copper-free aluminum, protected by our VanGuard baked polymer finish system. Page 27 Inserts Vantage inserts come in power (30 thru 260 AMP) and control (10 thru 100 contacts) versions. Within these power and control versions many options are available. Pages 29 thru 36 depict the inserts available with their electrical ratings, certifications and available key positions. Inserts are designed for simplified field termination. Power inserts feature captive contacts that utilize pressure termination. Control inserts utilize crimp contacts that are rear insertable, rear removable. Consult factory for replacements. Grounding Power inserts feature ground contacts which provide shell grounding, polarization, and make-first, break last function. Many control inserts feature ground contacts which provide shell grounding and make-first, break last function. Relay Circuits Some inserts are available with a pair of relay contacts that are shorter than all other contacts to provide a time delay during breaking and making. CONTROL CONTACTS CRIMP TERMINATION, REAR INSERTABLE - REAR REMOVABLE POWER CONTACTS PRESSURE TERMINATION, NON-REMOVABLE GROUND PIN LINE PIN LINE PIN 0.125 [3.2mm] 0.125 [3.2mm] RELAY PIN 0.125 [3.2mm] GROUND PIN (POLARIZED) Plating Options Control contacts come standard with silver plating. Gold plating is available for added corrosion resistance. The following plating options are available. Ferrules Ferrules are designed to serve as a compression supporting member when an undersized wire is crimp terminated into a larger contact. Ferrules are gold plated. Symbol L K D Contact Size AWG (mm2) Pin or Socket Part Number Ferrule Size Finish Silver Gold over Silver Gold over Nickel 10 (6) 12 (4) VT-70065-1012K 12 VT-70065-1014K 14 VT-70065-1016K 16 VT-70065-1216K 16 VT-70065-1218K 18 VT-70065-1220K 20 VT-70065-1620K VT-70065-1622K Example: To transition From #12 contact to #20 wire, use V-70065-1220K. 16 (1.5) 20 22 Thermocouple Contacts AF / SF inserts with 16 AWG contacts can be ordered with thermocouple contacts. Part Number / Gender VT-4016-50MF / Pin VT-4116-50MF / Socket VT-4016-50NF / Pin VT-4116-50NF / Socket VT-4016-50PO / Pin VT-4116-50PO / Socket VT-4016-50RO / Pin VT-4116-50RO / Socket ISA Symbol J J J J K K K K Thermocouple Material ISA Color Coding (+) (-) Jacket Temperature Range Degrees Continuous Short Time Iron White Red Black 0-1100° C to 1100° C Yellow Red Yellow 0-1100° C to 1350° C Constantan Chromel Alumel Note: Iron and Alumel contacts are magnetic. Constantan and Chromel contacts are non-magnetic. Termination Information All inserts are designed for simplified field termination. Control inserts require the use of Vantage crimp tools for safe and reliable circuits. See page 38 for more information. Page 28 The Vantage Inserts presented in this section illustrate the contact configurations available in the StarLine series. Most inserts are available in alternate key positions to prevent the inter-mating of like configurations in your system. Power inserts (GD/SD, GB/SB & BM) are designed with oversized contacts to maximize cooling. Wire size indicates maximize wire gauge that can be terminated to contact. 3 Contacts Insert Reference Pins: GB / GD-16-51PL Sockets: GB / GD-16-51SL Contact Quantity 3 Contact AWG (mm2) 4 (25) 1000 VAC 50/60/400Hz Non-Circuit Breaking 32 AMP 600 VAC 60/400Hz Circuit Breaking 30 AMP 480 VAC 60/400Hz Circuit Breaking 30 AMP Wire AWG 2 (mm ) 8 (10) KEY N 01 02 03 04 05 06 07 Shell Size 16 POSITION 0° 40° 90° 140° 180° 210° 280° 320° 3 Contacts Insert Reference Pins: GB / GD-20-61PL Sockets: GB / GD-20-61SL Contact Quantity 3 Contact AWG 2 (mm ) 1/0 (55) 1000 VAC 50/60/400Hz Non-Circuit Breaking 63 AMP 600 VAC 60/400Hz Circuit Breaking 60 AMP 480 VAC 60/400Hz Circuit Breaking 60 AMP Wire AWG 2 (mm ) Shell Size 4 (25) 20 KEY N 01 02 03 04 05 06 07 POSITION 0° 40° 90° 140° 180° 210° 280° 320° 3 Contacts Insert Reference Pins: GB / GD-24-60PL Sockets: GB / GD-24-60SL Contact Quantity Contact AWG (mm2) Wire AWG (mm2) Shell Size 3 4/0 (120) 1/0 (55) 24 1000 VAC 50/60/400Hz Non-Circuit Breaking 125 AMP 600 VAC 60/400Hz Circuit Breaking 100 AMP 480 VAC 60/400Hz Circuit Breaking 100 AMP KEY N 01 02 03 04 05 06 07 POSITION 0° 40° 90° 140° 180° 210° 280° 320° Page 29 3 Contacts Insert Reference Pins: GB / GD-28-30PL Sockets: GB / GD-28-30SL Contact Quantity 3 Contact AWG (mm2) 350 MCM (185) 1000 VAC 50/60/400Hz Non-Circuit Breaking 260 AMP 600 VAC 60/400Hz Circuit Breaking 200 AMP 480 VAC 60/400Hz Circuit Breaking 200 AMP GB not UL or CSA listed. Wire AWG (mm2) Shell Size 4/0 (120) 28 KEY N 01 02 03 04 05 06 07 08 09 10 POSITION 0° 30° 60° 90° 120° 150° 180° 210° 270° 300° 330° 4 Contacts Insert Reference Pins: GB / GD-16-23PL Sockets: GB / GD-16-23SL Contact Quantity Contact AWG (mm2) Wire AWG (mm2) Shell Size 4 4 (25) 8 (10) 16 1000 VAC 50/60/400Hz Non-Circuit Breaking 32 AMP 600 VAC 60/400Hz Circuit Breaking 30 AMP 480 VAC 60/400Hz Circuit Breaking 30 AMP KEY N 01 02 03 04 05 POSITION 0° 105° 120° 315° 330° 345° 4 Contacts Insert Reference Pins: GB / GD-20-40PL Sockets: GB / GD-20-40SL Contact Quantity Contact AWG (mm2) Wire AWG (mm2) Shell Size 4 1/0 (55) 4 (25) 20 1000 VAC 50/60/400Hz Non-Circuit Breaking 63 AMP 600 VAC 60/400Hz Circuit Breaking 60 AMP 480 VAC 60/400Hz Circuit Breaking 60 AMP KEY N 01 02 03 04 POSITION 0° 15° 165° 300° 330° 4 Contacts Contact AWG 2 (mm ) 4/0 (120) Wire AWG 2 (mm ) 1/0 (55) 1000 VAC 50/60/400Hz Non-Circuit Breaking 125 AMP 600 VAC 60/400Hz Circuit Breaking 100 AMP 480 VAC 60/400Hz Circuit Breaking 100 AMP KEY N 01 02 03 04 05 Insert Reference Pins: GB / GD-24-39PL Sockets: GB / GD-24-39SL Page 30 Contact Quantity 4 Shell Size 24 POSITION 0° 15° 165° 300° 315° 330° 4 Contacts Insert Reference Pins: GDU-28-31PL Sockets: GDU-28-31SL Contact Quantity 4 1000 VAC 50/60/400Hz Non-Circuit Breaking Contact AWG Wire AWG Shell Size (mm2) (mm2) 350 MCM 4/0 (120) 28 (185) 260 AMP 600 VAC 60/400Hz Circuit Breaking 200 AMP 480 VAC 60/400Hz Circuit Breaking 200 AMP KEY N 01 02 03 POSITION 0° 60° 120° 195° 5 Contacts Insert Reference Pins: GB / GD-20-36PL Sockets: GB / GD-20-36SL Contact Quantity 5 1000 VAC 50/60/400Hz Non-Circuit Breaking Contact AWG Wire AWG (mm2) (mm2) 4 (25) 8 (10) Shell Size 20 32 AMP 600 VAC 60/400Hz Circuit Breaking 30 AMP 480 VAC 60/400Hz Circuit Breaking 30 AMP KEY N 01 02 POSITION 0° 51° 159° 5 Contacts Insert Reference Pins: GB / GD-24-29PL Sockets: GB / GD-24-29SL Contact Quantity 5 Contact AWG Wire AWG (mm2) (mm2) 1/0 (55) 1000 VAC 50/60/400Hz Non-Circuit Breaking 63 AMP 600 VAC 60/400Hz Circuit Breaking 60 AMP 480 VAC 60/400Hz Circuit Breaking 60 AMP 4 (25) KEY N 01 02 03 Shell Size 24 POSITION 0° 36° 90° 198° Page 31 5 Contacts Insert Reference Pins: GB / GD-28-23PL Sockets: GB / GD-28-23SL Contact Contact AWG Wire AWG (mm2) Quantity (mm2) 5 4/0 (120) 1000 VAC 50/60/400Hz Non-Circuit Breaking Shell Size 1/0 (55) 28 125 AMP 600 VAC 60/400Hz Circuit Breaking 100 AMP 480 VAC 60/400Hz Circuit Breaking 100 AMP KEY N 01 02 03 POSITION 0° 90° 126° 180° 6 Contacts Insert Reference Pins: GD-28-42PL Sockets: GD-28-42SL NOTE: Relay pins 5 & 6 are shorter to make last / break first Contact Contact AWG Wire AWG (mm2) Quantity (mm2) 4 4/0 (120) 4/0 (120) 2 10 (6) 10 (6) 1000 VAC 50/60/400Hz Non-Circuit Breaking 260 AMP 600 VAC 60/400Hz Circuit Breaking 200 AMP 480 VAC 60/400Hz Circuit Breaking 200 AMP KEY N 01 02 03 04 05 06 07 08 09 10 Shell Size 28 POSITION 0° 45° 67.5° 90° 126° 145° 180° 202.5° 225° 315° 337.5° 10 Contacts Insert Reference Pins: VT-16-681PL Sockets: VT-16-681SL Contact Quantity 6 4 Contact AWG 2 (mm ) 12 (4.0) 10 (6.0) 250 VAC 50/60/400Hz, 125 VDC Non-Circuit Breaking 20/30 AMP 250 VAC 60Hz Circuit Breaking 10 AMP KEY N 01 02 Shell Size 16 POSITION 0° 30° 45° 10 Contacts Insert Reference Pins: VT-16-676PL Sockets: VT-16-676SL Page 32 Contact Quantity 6 Contact AWG (mm2) 12 (4.0) 4 10 (6.0) 250 VAC 50/60/400Hz, 125 VDC Non-Circuit Breaking 20/30 AMP 250 VAC 60Hz Circuit Breaking 10 AMP KEY N 01 Shell Size 16 POSITION 0° 35° 19 Contacts Insert Reference Pins: VT-16-612PL Sockets: VT-16-612SL Contact Quantity Contact AWG (mm2) Shell Size 19 12 (4) 16 250 VAC 50/60/400Hz, 125 VDC Non-Circuit Breaking 20 AMP 250 VAC 60Hz Circuit Breaking 10 AMP KEY N 02 03 POSITION 0° 48° 144° 19 Contacts Insert Reference Pins: VT-16-677PL Sockets: VT-16-677SL Contact Quantity Contact AWG (mm2) Shell Size 19 12 (4) 16 250 VAC 50/60/400Hz, 125 VDC Non-Circuit Breaking 20 AMP 250 VAC 60Hz Circuit Breaking 10 AMP KEY N 01 POSITION 0° 24° 19 Contacts Insert Reference Pins: VT-20-676PL Sockets: VT-20-676SL Contact Quantity Contact AWG (mm2) Shell Size 19 12 (4) 20 250 VAC 50/60/400Hz, 125 VDC Non-Circuit Breaking 20 AMP 480 VAC Non-Circuit Breaking 250 VAC Circuit Breaking 60Hz 10 AMP KEY N 01 02 04 05 POSITION 0° 37° 84° 165° 235° 19 Contacts Insert Reference Pins: VT-20-688PL Sockets: VT-20-688SL Contact Quantity 19 250 VAC 50/60/400Hz, 125 VDC Non-Circuit Breaking 20 AMP 480 VAC Non-Circuit Breaking 250 VAC Circuit Breaking 60Hz 10 AMP Contact AWG (mm2) 12 (4) KEY N Shell Size 20 POSITION 0° Page 33 19 Contacts Insert Reference Pins: VT-16-655PL Sockets: VT-16-655SL Contact Quantity Contact AWG (mm2) Shell Size 19 16 (1.5) 16 250 VAC 50/60/400Hz, 125 VDC Non-Circuit Breaking 15 AMP 250 VAC 60Hz Circuit Breaking 6.5 AMP KEY N 01 02 03 04 05 06 07 08 09 POSITION 0° 36° 72° 108° 144° 180° 216° 252° 288° 324° 20 Contacts Insert Reference Pins: VT-20-632PL Sockets: VT-20-632SL Contact Quantity Contact AWG (mm2) Shell Size 20 12 (4) 20 250 VAC 50/60/400Hz, 125 VDC Non-Circuit Breaking 20 AMP 250 VAC 60Hz Circuit Breaking 10 AMP KEY N 01 POSITION 0° 42.5 20 Contacts Insert Reference Pins: VT-20-687PL Sockets: VT-20-687SL Contact Quantity Contact AWG (mm2) Shell Size 20 12 (4) 20 250 VAC 50/60/400Hz, 125 VDC Non-Circuit Breaking 20 AMP 250 VAC 60Hz Circuit Breaking 10 AMP KEY N 01 POSITION 0° 56° 37 Contacts Insert Reference Pins: VT-20-686PL Sockets: VT-20-686SL Page 34 Contact Quantity Contact AWG (mm2) Shell Size 37 12 (4) 20 250 VAC 50/60/400Hz, 125 VDC Non-Circuit Breaking 20 AMP 250 VAC 60Hz Circuit Breaking 10 AMP KEY N POSITION 0° 37 Contacts Insert Reference Pins: VT-20-650PL Sockets: VT-20-650SL Contact Quantity Contact AWG (mm2) Shell Size 37 12 (4) 20 250 VAC 50/60/400Hz, 125 VDC Non-Circuit Breaking 20 AMP 250 VAC 60Hz Circuit Breaking 10 AMP KEY N 01 02 POSITION 0° 30° 100° 37 Contacts Insert Reference Pins: VT-16-621PL Sockets: VT-16-621SL Contact Quantity Contact AWG (mm2) Shell Size 37 16 (1.5) 16 250 VAC 50/60/400Hz, 125 VDC Non-Circuit Breaking 15 AMP 250 VAC 60Hz Circuit Breaking 6.5 AMP KEY N 01 02 03 04 05 06 07 08 09 POSITION 0° 32.5° 65° 97.5° 130° 162.5° 195° 227.5° 260° 292.5° 55 Contacts Insert Reference Pins: VT-16-640PL Sockets: VT-16-640SL Contact Quantity Contact AWG (mm2) Shell Size 55 18 (0.75) 16 250 VAC 50/60/400Hz, 125 VDC Non-Circuit Breaking 10 AMP 250 VAC 60Hz Circuit Breaking 3.5 AMP KEY N 01 02 03 04 05 06 07 08 09 10 POSITION 0° 32° 60° 90° 117° 150° 180° 220° 255° 285° 345° Page 35 61 Contacts Insert Reference Pins: VT-16-633PL Sockets: VT-16-633SL Contact Quantity Contact AWG 2 (mm ) Shell Size 61 18 (.75) 16 250 VAC 50/60/400Hz, 125 VDC Non-Circuit Breaking 10 AMP 250 VAC 60Hz Circuit Breaking 3.5 AMP KEY N 01 02 03 04 POSITION 0° 75° 105° 150° 232.5° 68 Contacts Insert Reference Pins: VT-20-613PL Sockets: VT-20-613SL Contact Quantity Contact AWG 2 (mm ) Shell Size 68 16 (1.5) 20 250 VAC 50/60/400Hz, 125 VDC Non-Circuit Breaking 15 AMP 250 VAC 60Hz Circuit Breaking 6.5 AMP KEY N 02 03 04 05 POSITION 0° 45° 157.5° 228° 292.5° 100 Contacts Insert Reference Pins: VT-24-613PL Sockets: VT-24-613SL Page 36 Contact Quantity Contact AWG 2 (mm ) Shell Size 100 16 (1.5) 24 250 VAC 50/60/400Hz, 125 VDC Non-Circuit Breaking 15 AMP 250 VAC 60Hz Circuit Breaking 5.0 AMP KEY N 02 03 04 05 POSITION 0° 30° 90° 240° 300° ØA ØB WASHER Shell Size Dim B Inches (mm) 16 1 23/32 (43.7) ØB ØA 20 2 7/32 (56.4) MIN. MAX. Cable Diameter Code Number* .250 (6.35) .375 (9.53) .375 (9.53) .500 (12.7) 06 08 VT-6316-6C VT-6316-8C VT-8016-8E VT-5016-6E VT-5016-8E .500 (12.7) .625 (15.9) .625 (15.9) .750 (19.1) 10 12 VT-6316-10C VT-6316-12C VT-8016-12E VT-5016-10E VT-5016-12E .750 (19.1) .875 (22.2) .875 (22.2) 1.000 (25.4) 14 16 VT-6316-14C VT-6316-16C VT-8016-16E VT-5016-14E VT-5016-16E 1.000 (25.4) 1.125 (28.6) 1.125 (28.6) 1.250 (31.8) 18 20 VT-6316-18C VT-6316-20C VT-8016-20E VT-5016-18E VT-5016-20E 1.250 (31.8) 1.375 (34.9) 1.375 (34.9) 1.437 (36.5) 22 23 VT-6316-22C VT-6316-23C VT-8016-23E VT-5016-22E VT-5016-23E .500 (12.7) .625 (15.9) .625 (15.9) .750 (19.1) 10 12 VT-6320-10C VT-6320-12C VT-8020-12E VT-5020-10E VT-5020-12E .750 (19.1) .875 (22.2) .875 (22.2) 1.000 (25.4) 14 16 VT-6320-14C VT-6320-16C VT-8020-16E VT-5020-14E VT-5020-16E 1.000 (25.4) 1.125 (28.6) 1.125 (28.6) 1.250 (31.8) 18 20 VT-6320-18C VT-6320-20C VT-8020-20E VT-5020-18E VT-5020-20E 1.250 (31.8) 1.375 (34.9) 1.375 (34.9) 1.500 (38.1) 22 24 VT-6320-22C VT-6320-24C VT-8020-24E VT-5020-22E VT-5020-24E 1.500 (38.1) 1.625 (41.3) 1.625 (41.3) 1.750 (44.5) 26 28 VT-6320-26C VT-6320-28C VT-8020-28E VT-5020-26E VT-5020-28E 1.750 (44.5) 1.875 (47.6) 1.875 (47.6) 1.937 (49.2) 30 31 VT-6320-30C VT-6320-31C VT-8020-31E VT-5020-30E VT-5020-31E .875 (22.2) 1.000 (25.4) 16 VT-6324-16C VT-8024-16E VT-5024-16E 1.000 (25.4) 1.125 (28.6) 1.125 (28.6) 1.250 (31.8) 18 20 VT-6324-18C VT-6324-20C VT-8024-20E VT-5024-18E VT-5024-20E 1.250 (31.8) 1.375 (34.9) 1.375 (34.9) 1.500 (38.1) 22 24 VT-6324-22C VT-6324-24C VT-8024-24E VT-5024-22E VT-5024-24E 1.500 (38.1) 1.625 (41.3) 1.625 (41.3) 1.750 (44.5) 26 28 VT-6324-26C VT-6324-28C VT-8024-28E VT-5024-26E VT-5024-28E 1.750 (44.5) 1.875 (47.6) 1.875 (47.6) 2.000 (50.8) 30 32 VT-6324-30C VT-6324-32C VT-8024-32E VT-5024-30E VT-5024-32E 2.000 (50.8) 2.125 (54.0) 2.125 (54.0) 2.250 (57.2) 34 36 VT-6324-34C VT-6324-36C VT-8024-36E VT-5024-34E VT-5024-36E 2.250 (57.2) 2.375 (60.3) 2.375 (60.3) 2.437 (61.9) 38 39 VT-6324-38C VT-6324-39C VT-8024-39E VT-5024-38E VT-5024-39E 1.375 (34.9) 1.500 (38.1) 24 VT-6328-24C VT-8028-24E VT-5028-24E 1.500 (38.1) 1.625 (41.3) 1.625 (41.3) 1.750 (44.5) 26 28 VT-6328-26C VT-6328-28C VT-8028-28E VT-5028-26E VT-5028-28E 1.750 (44.5) 1.875 (47.6) 1.875 (47.6) 2.000 (50.8) 30 32 VT-6328-30C VT-6328-32C VT-8028-32E VT-5028-30E VT-5028-32E 2.000 (50.8) 2.125 (54.0) 2.125 (54.0) 2.250 (57.2) 34 36 VT-6328-34C VT-6328-36C VT-8028-36E VT-5028-34E VT-5028-36E 2.250 (57.2) 2.375 (60.3) 2.375 (60.3) 2.500 (63.5) 38 40 VT-6328-38C VT-6328-40C VT-8028-40E VT-5028-38E VT-5028-40E 2.500 (63.5) 2.625 (66.7) 2.625 (66.7) 2.750 (68.9) 42 44 VT-6328-42C VT-6328-44C VT-8028-44E VT-5028-42E VT-5028-44E 2.750 (68.9) 2.875 (73.0) 46 VT-6328-46C VT-8028-46E VT-5028-46E Cable Diameter Dimension A Inches (mm) Grommet Part Number Washer Part Number Basket Weave Grip Part Number BASKET WEAVE GRIP ØB ØA 24 2 23/32 (69.1) GROMMET Specialty grommets are available for multi-hole and flat cable systems. Consult factory. 28 3 5/32 (80.2) *The cable diameter code is used to define the grommet size in the connector part number. For example, connector AFB1516-621SL-18 comes with a size “18” grommet, for use with a cable whose diameter range is 1.000 – 1.125 inches (25.4 - 28.6mm). Page 37 Vantage offers a full line of tooling to assist in the termination and assembly of our attachment plugs and receptacles. StarLine, GD/SD, GB/SB & BM Series and StrateLine power connectors, feature pressure termination and come with all required tooling. For StarLine control connectors, the AF/SF & BM Series, Vantage requires using a full-cycle eight indent crimp tool. Please contact us for assistance in specifying your tooling needs. Pressure Termination for safe and reliable assembly in the field. Crimp Tools T-104-CT-K Crimp Tool Kit. Hand tool with accessories for contacts #18 through #10 (carrying case and tool inspection gage not shown). T-103-CT-K Crimp Tool Kit. Hand tool with accessories for contacts #18 through #10, shown with turret head detached (carrying case and tool inspection gage not shown). VANTAGE TECHNOLOGY T-105-HE, Pneumatic Crimp Tool. Available with dies, locators and inspection gages for #18 through #4/0 contacts. A foot control is also available. Operates on shop air and inert gas cylinders at 100 PSI. Vantage Technology Contact Extraction Tool Pin and socket contact extraction tool for AF, BM and SF control connectors. Contact Size 18 Extraction Tool Part Number T-106-18 16 T-106-16 12 T-106-12 10 T-106-10 Assembly Tools Plug Assembly Tool Furnished with plug. Shell Size 16 Part Number Plug Assembly Plug Disassembly Tool Tool T-101-16A T-102-16R 20 T-101-20A T-102-20R 24 T-101-24A T-102-24R 28 T-101-28A T-102-28R Cable Assemblies Complete cable assemblies and receptacle distribution boxes are available incorporating Vantage Technology connectors. Please contact us regarding specification options. Page 38 Plug Disassembly Tool Ordered separately. AF/SF GD/SD BM Stainless Steel Weight Factor 2.0 Shell Size 16 A INCHES ±0.3 (mm ±8) 9.3 (236) B INCHES ±0.3 (mm ±8) 10.3 (262) C INCHES (mm) 2.977 (75.6) D INCHES ±0.3 (mm ±8) 8.4 (213) 3.75 - 10.25 (95 - 260) Weight1 LBS (kg) 4.0 (1.8) 20 10.0 (254) 11.0 (279) 3.577 (90.9) 9.0 (229) 5.75 - 14.25 (146 - 362) 5.2 (2.4) 24 10.4 (264) 11.4 (290) 4.182 (106.2) 9.4 (239) 8.25 - 17.25 (210 - 438) 7.2 (3.3) 28 10.9 (277) 11.9 (302) 4.814 (122.3) 9.8 (249) 13.75 - 19.75 (349 - 502) 9.1 (4.1) 16 10.3 (262) 11.3 (287) 2.977 (75.6) 9.4 (238) 3.75 - 10.25 (95 - 260) 3.9 (1.8) 20 11.0 (279) 12.0 (305) 3.577 (90.9) 10.0 (254) 5.75 - 14.25 (146 - 362) 6.0 (2.7) 24 11.4 (290) 12.4 (315) 4.182 (106.2) 10.4 (264) 8.25 - 17.25 (210 - 438) 8.4 (3.8) 28 11.9 (302) 12.9 (328) 4.814 (122.3) 10.8 (274) B A 13.75 - 19.75 (349 - 502) 12.1 (5.5) GB/SB GDU/SDU Stainless Steel Weight Factor 2.0 Attachment Plug E INCHES (mm) 1 12 2 11 13 18 10 14 3G 19 9 17 4 15 16 5 6 8 7 1. Weights provided for Victory Series (aluminum) with mechanical clamp configuration. Multiply by "Stainless Steel Weight Factor" to determine weight for Millennium Series (stainless steel). ØC PLUG FACE (INSERT 16-612PL SHOWN) D AF/SF GD/SD BM Stainless Steel Weight Factor 2.4 Shell Size 16 GB/SB GDU/SDU Stainless Steel Weight Factor 2.4 E F INCHES (mm) G INCHES (mm) H INCHES (mm) NPT THREAD ‘J’ Weight1 LBS (kg) 2.9 (1.3) 7.9 (200) 6.9 (175) 2.977 (75.6) 1 ¼ - 11 ½ 20 8.2 (208) 7.2 (183) 3.577 (90.9) 1 ½ - 11 ½ 4.0 (1.8) 24 8.4 (213) 7.4 (188) 4.182 (106.2) 2 – 11 ½ 5.4 (2.5) 28 8.8 (224) 7.8 (198) 4.814 (122.3) 2½-8 7.2 (3.3) 16 8.9 (226) 7.9 (201) 2.977 (75.6) 1 ¼ - 11 ½ 3.4 (1.5) 20 9.2 (234) 8.2 (208) 3.577 (90.9) 1 ½ - 11 ½ 5.0 (2.3) 24 9.4 (239) 8.4 (213) 4.182 (106.2) 2 – 11 ½ 7.4 (3.4) 28 9.8 (249) 8.8 (224) 4.814 (122.3) 2½-8 9.5 (4.3) F G THREAD 'J' NPT Tapped Plug 1 12 2 18 10 14 3G 11 13 9 17 16 5 6 8 7 AF/SF GD/SD BM Stainless Steel Weight Factor 2.0 4 15 1. Weights provided for Victory Series (aluminum). Multiply by "Stainless Steel Weight Factor" to determine weight for Millennium Series (stainless steel). ØH 19 PLUG FACE (INSERT 16-612PL SHOWN) Weight1 LBS (kg) 3.4 (1.5) Shell Size 16 K INCHES ±0.3 (mm ±8) 10.0 (254) L INCHES ±0.3 (mm ±8) 9.1 (231) M INCHES (mm) N INCHES (mm) 3.75 - 10.25 (95 - 260) 1.969 (50.1) 3.063 (77.8) 20 10.7 (272) 9.7 (246) 5.75 - 14.25 (146 - 362) 2.469 (62.7) 3.563 (90.5) 4.7 (2.1) 24 11.1 (282) 10.1 (257) 8.25 - 17.25 (210 - 438) 2.969 (75.4) 4.188 (106.4) 6.4 (2.9) 28 11.4 (290) 11.0 (279) 10.3 (262) 13.75 - 19.75 (349 - 502) 3.469 (88.1) 4.688 (119.1) 8.1 (3.7) 16 10.1 (257) 3.75 - 10.25 (95 - 260) 1.969 (50.1) 3.063 (77.8) 3.6 (1.6) 20 11.7 (297) 10.7 (272) 5.75 - 14.25 (146 - 362) 2.469 (62.7) 3.563 (90.5) 4.9 (2.2) 24 12.1 (307) 11.1 (282) 8.25 - 17.25 (210 - 438) 2.969 (75.4) 4.188 (106.4) 6.7 (3.0) 28 12.4 (315) 11.3 (287) 13.75 - 19.75 (349 - 502) 3.469 (88.1) 4.688 (119.1) 8.6 (3.9) GB/SB GDU/SDU Stainless Steel Weight Factor 2.0 COVER ADDS .8 (20.3mm) INCHES TO DIMENSIONS "K" AND "L" Attachment Receptacle ØP 3.53 (89.7mm) K ØN 3 4G 2 1 1. Weights provided for Victory Series (aluminum) with mechanical clamp configuration. Multiply by "Stainless Steel Weight Factor" to determine weight for Millennium Series (stainless steel). P INCHES (mm) RECEPTACLE FACE L M Page 39 16 A INCHES1 (mm) 4.063 (103.2) B INCHES1 (mm) 3.063 (77.8) 20 4.063 (103.2) 3.063 (77.8) 2.469 (62.7) 24 4.063 (103.2) 3.063 (77.8) 2.969 (75.4) 28 4.063 (103.2) 3.063 (77.8) 3.469 (88.1) 4.688 (119.1) 16 5.063 (128.6) 4.063 (103.2) 1.969 (50.0) 3.063 (77.8) 2 3 (1.4) 20 24 5.063 (128.6) 4.063 (103.2) 2.469 (62.7) 3.563 (90.5) 2½ 5 (2.3) 5.063 (128.6) 4.063 (103.2) 2.969 (75.4) 4.188 (106.4) 3 1/8 8 (3.6) 28 5.063 (128.6) 4.063 (103.2) 3.469 (88.1) 4.688 (119.1) 3 5/8 14 (6.4) Dimension Shell Size AF/SF GD/SD BM Stainless Steel Weight Factor 1.4 GB/SB GDU/SDU Stainless Steel Weight Factor 1.6 PANEL MOUNT RECEPTACLE MOUNTING DIMENSIONS Panel Mount Receptacle THREAD ‘E’ G-16UN 2 Weight LBS2 (kg) 3 (1.4) 3.563 (90.5) 2½ 4 (1.8) 4.188 (106.4) 3 1/8 8 (3.6) 3 5/8 13 (5.9) C INCHES (mm) D INCHES (mm) 1.969 (50.0) 3.063 (77.8) COVER ADDS .8 INCHES (20.3mm) TO DIMENSIONS "A" AND "B" 3.531 (89.7mm) A B ØJ 3 1 ØC 2 1 L 3 4G 4G ØK 2 NOTE: THE CUTOUT DIMENSION "J" INCLUDES 0.0625" (1.6mm) RECEPTACLE SHELL CLEARANCE. 1. Subtract 0.5 inches (12.7mm) from dimensions A and B Receptacle for AF/SF style. GD-B1716-23SL 2. Weights provided for -L36 Shown Victory Series (aluminum). Multiply by "Stainless Steel Weight Factor" to determine weight for Millennium Series (stainless steel). ØD 36" (914.4 mm) STANDARD LENGTH E THREAD SIZE 'F' SQ WEIGHT, ANGLE ADAPTER LBS SHELL SIZE 0.5 16 0.5 20 2.9 24 2.9 28 "G" SQ KG 0.23 0.23 1.30 1.30 ØH (4X) 45° ANGLE ADAPTER AND GASKET (OPTIONAL) Mounting Dimensions Shell Size F INCHES (mm) G INCHES (mm) H INCHES (mm) J INCHES (mm) K INCHES (mm) L INCHES (mm) 16 4.5 (114.3) 3.875 (98.4) 0.284 (7.2) 2.063 (52.4) 0.195 (5.0) 2.610 (66.3) 20 4.5 (114.3) 3.875 (98.4) 0.284 (7.2) 2.563 (65.1) 0.195 (5.0) 3.110 (79.0) 24 8 (203.2) 7 (177.8) 0.534 (13.6) 3.063 (77.8) 0.195 (5.0) 3.735 (94.9) 28 8 (203.2) 7 (177.8) 0.534 (13.6) 3.563 (90.5) 0.195 (5.0) 4.235 (107.6) AF/SF GD/SD BM Stainless Steel Weight Factor 1.6 Shell Size 16 20 24 M INCHES (mm) 2.5 (63.5) 3 (76.2) 3.5 (88.9) N INCHES (mm) 2.875 (73.0) 3.469 (88.1) 4.031 (102.4) P INCHES1 (mm) 4.5 (114.3) 4.531 (115.1) 4.906 (124.6) 28 4 (101.6) 2.5 (63.5) 3 (76.2) 3.5 (88.9) 4 (101.6) 4.625 (117.5) 4.969 (126.2) 3.656 (92.9) 2.875 (73.0) 3.469 (88.1) 4.031 (102.4) 4.625 (117.5) 5 (127.0) 5.031 (127.8) 5.406 (137.3) 5.469 (138.9) 4.156 (105.6) 4.156 (105.6) 4.156 (105.6) 4.156 (105.6) GB/SB GDU/SDU Stainless Steel Weight Factor 1.7 NPT Mount Receptacle 16 20 24 28 "M" HEX ACROSS FLATS 1 2 12 11 4 15 18 17 9 16 5 COVER ADDS .8 INCHES (20.3mm) TO DIMENSIONS "P" AND "Q" Weight LBS2 (kg) 3 (1.4) 5 (2.3) 8 (3.6) 3-8 3.469 (88.1) 13 (5.9) 1 ½ - 11 ½ 2 – 11 ½ 2½-8 3-8 1.969 (50.0) 2.469 (62.7) 2.969 (75.4) 3.469 (88.1) 3 (1.4) 5 (2.3) 9 (4.1) 14 (6.4) P THREAD 'R' Q 3.53 (89.7mm) "N" HEX ACROSS CORNERS S INCHES (mm) 1.969 (50.0) 2.469 (62.7) 2.969 (75.4) NPT THREAD ‘R’ 1 ½ - 11 ½ 2 – 11 ½ 2½-8 ØS 8 7 6 Page 40 10 1. Subtract 0.5 inches (12.7mm) from dimensions P and Q for AF/SF style. 2. Weights provided for Victory Series (aluminum). Multiply by "Stainless Steel Weight Factor" to determine weight for Millennium Series (stainless steel). 14 3G 13 19 Q INCHES1 (mm) 3.656 (92.9) 3.656 (92.9) 3.656 (92.9) 3X ALLEN HEAD SET SCREW FOR LOCKING PANEL MOUNTED RECEPTACLE IN PLACE 0.75 (19.1mm) 36" (914.4 mm) STANDARD LENGTH AF-B1916-612SL-L36 Shown Receptacle, Junction Box Shell Size AF/SF GD/SD BM Stainless Steel Weight Factor 1.2 GB/SB GDU/SDU Stainless Steel Weight Factor 1.2 A INCHES (mm) B INCHES (mm) C INCHES (mm) D INCHES (mm) 1 Weight LBS (kg) 16 10.063 (255.6) 10.25 (260.4) 7.375 (187.3) 7.75 (196.9) 12.9 (5.9) 20 10.063 (255.6) 10.25 (260.4) 7.375 (187.3) 7.75 (196.9) 13.7 (6.2) 24 14.563 (370.0) 14 (355.6) 9.688 (246.1) 10.125 (257.2) 21.9 (9.9) 28 14.563 (370.0) 14 (355.6) 9.688 (246.1) 10.125 (257.2) 22.8 (10.3) 16 11.563 (293.7) 11.125 (282.6) 7.875 (200.0) 8.25 (209.6) 13.0 (5.9) 20 11.563 (293.7) 11.125 (282.6) 7.875 (200.0) 8.25 (209.6) 13.9 (6.3) 24 15.438 (392.1) 14.875 (377.8) 10.188 (258.8) 10.625 (269.9) 22.5 (10.2) 28 15.438 (392.1) 14.875 (377.8) 10.188 (258.8) 10.625 (269.9) 23.2 (10.5) 1. Weights provided for Victory Series (aluminum). Multiply by "Stainless Steel Weight Factor" to determine weight for Millennium Series (stainless steel). CL NPT HUB TOP & BOT A 85 8 [219.5mm] B D C 11 [Ø8.7mm] 4X Ø32 15 8 [41.4mm] 11 [Ø8.7mm] 4X Ø32 75 8 [194.1mm] A B 75 8 [194.1mm] 85 8 [219.5mm] 4 [101.8mm] 5 [134.9mm] 516 C 4 [101.8mm] CL NPT HUB D SHELL SIZES 16 AND 20 11 [59.2mm] 232 5 [160.7mm] 616 SHELL SIZES 24 AND 28 Receptacle, Ground Power POWER BOX COVER MAXIMUM DIAMETER OF SECOND CONDUIT TAP IN SIDE WALL IS 2 1/2" Ø19.8 [Ø502mm] 14.8 [375mm] SIDE 4" MAXIMUM CONDUIT SIZE SIDE "D" POWER BOX COVER INTERMEDIATE COVER 6.9 [174mm] SIDE "A" SIDE "C" POWER BOX SIDE "B" BOTTOM 23.5 [596mm] WEIGHT LBS (kg) 65 (29.5) POWER BOX COVER 191 (86.6) INTERMEDIATE COVER 409 (185.5) POWER BOX 665 (301.6) COMPLETE ASSEMBLY Page 41 GB - 1 B 17 16 2 3 4 1. Classification GB / SB GD / SD BM GDU / SDU GDT / SDT - = = = = = 23 S L 01 5 6 7 8 Groups B-C-D areas & Groups B-C-D areas & Group F-G areas Groups B-C-D areas & Groups B-C-D areas & - FH - XX 9 10 EEx d IIC T6 IP 66/67 T70° EEx d IIC T6 IP 66/67 T70° EEx d IIC T6 IP 66/67 T70° EEx d IIC T6 IP 66/67 T70° 2. Cover B = Cover 3. Shell Style 17 = Receptacle for Junction Box or Panel-mount 19 = Receptacle for NPT-mount 4. Shell Size 16 = Shell Size 16 20 = Shell Size 20 24 = Shell Size 24 28 = Shell Size 28 5. Insert 30 thru 260 amps – through 1000 VAC. See Insert Code column in Insert Table below. 6. Gender S = Female (Socket) Insert Shell Size 16 = 1 ½” NPT Shell Size 20 = 2” NPT Shell Size 24 = 2 ½” NPT Shell Size 28 = 3” NPT P = Male (Pin) Insert 7. Contact Plating L = Silver Plate (Standard). Ground contacts are gold over silver. 8. Insert Keying Alternate = See Key Positions column in Insert Table. Blank = Normal Key 9. Hub Accessory See Junction Box Table 10. Wire Lead Variation Blank = Panel / 17 Style or NPT / 19 Style See Wire Length Table Receptacle, Junction Box Per customer requirements. Receptacle, Junction Box Receptacle, Panel-Mount Receptacle, NPT INSERT TABLE (Reference Pages 29 thru 32) WIRE LENGTH AMPERES 30 60 100 200 32 63 125 260 INSERT SHELL SIZE 2 POLE, 3 WIRE 16 51 N+5 3 POLE, 4 WIRE 16 23 N+5 4 POLE, 5 WIRE 20 36 N+2 CODE INSERT KEY 1 CODE POSITIONS 2 POLE, 3 WIRE 20 61 N+7 3 POLE, 4 WIRE 20 40 N+4 4 POLE, 5 WIRE 24 29 N+3 2 POLE, 3 WIRE 24 60 N+7 3 POLE, 4 WIRE 24 39 N+5 4 POLE, 5 WIRE 28 23 N+3 2 POLE, 3 WIRE 28 30 N+9 3 POLE, 4 WIRE 28 31 N + 10 5 POLE 6 WIRE (3 POLE 4 WIRE and 2 relay contacts) 28 42 N+3 1. NORMAL KEY POSITION = N; ALTERNATE KEYS = 01, 02, ETC. Meters L12 12 0.31 L24 24 0.61 L36 36 Etc 0.91 Etc JUNCTION BOX SHELL SIZE CONDUIT HUB CONDUIT HUB LOCATION SIZE (Inches) 16 & 20 ‘F’ ‘H’ TOP & BOTTOM 1½ - 11½ NPT 24 ‘B’ BOTTOM ‘K’ 2½ - 8 NPT 28 ‘B’ BOTTOM ‘L’ 3 - 8 NPT Example: Suffix “-FH” denotes thru feed with a 1½ inch hub. Note: Code logic is provided to identify features called out by standard part numbers. Not all component codes are compatible with all others. Reference part number tables under appropriate product sections of this catalog or consult Vantage Technology. Page 42 LENGTH Inches GB - 1 D 10 16 2 3 4 1. Classification GB / SB GD / SD BM GDU / SDU GDT / SDT - = = = = = 51 P L 01 5 6 7 8 Groups B-C-D areas & Groups B-C-D areas & Group F-G areas Groups B-C-D areas & Groups B-C-D areas & XX 9 EEx d IIC T6 IP 66/67 T70° EEx d IIC T6 IP 66/67 T70° EEx d IIC T6 IP 66/67 T70° EEx d IIC T6 IP 66/67 T70° 2. Cover Blank = No Cover 3. Shell Style 10 = Plug, Attachment Style 15 = Receptacle, Attachment Style 4. Shell Size 16 = Shell Size 16 20 = Shell Size 20 5. Insert 30 thru 260 amps – through 1000 VAC. See Insert Code column in Insert Table below. 6. Gender S = Female (Socket) Insert 7. Contact Plating L = Silver plate (Standard). Ground contacts are gold over silver. 8. Insert Keying Blank = Normal Key 9. Grommet Replace XX with cable diameter code number from Page 37. Plug, Attachment - B = Cover / Receptacle D = Cover / Plug 24 = Shell Size 24 28 = Shell Size 28 P = Male (Pin) Insert Alternate = See Key Positions column in Insert Table. Plug, Conduit Tapped Receptacle, Attachment TC = Tapped Conduit Receptacle, Conduit Tapped INSERT TABLE (Reference Pages 29 thru 32) AMPERES 30 60 100 200 32 63 125 260 INSERT SHELL SIZE INSERT KEY 1 CODE POSITIONS 2 POLE, 3 WIRE 16 51 N+5 3 POLE, 4 WIRE 16 23 N+5 4 POLE, 5 WIRE 20 36 N+2 2 POLE, 3 WIRE 20 61 N+7 3 POLE, 4 WIRE 20 40 N+4 4 POLE, 5 WIRE 24 29 N+3 2 POLE, 3 WIRE 24 60 N+7 3 POLE, 4 WIRE 24 39 N+5 4 POLE, 5 WIRE 28 23 N+3 2 POLE, 3 WIRE 28 30 N+9 3 POLE, 4 WIRE 28 31 N + 10 5 POLE 6 WIRE (3 POLE 4 WIRE and 2 relay contacts) 28 42 N+3 Note: Code logic is provided to identify features called out by standard part numbers. Not all component codes are compatible with all others. Reference part number tables under appropriate product sections of this catalog or consult Vantage Technology. 1. NORMAL KEY POSITION = N; ALTERNATE KEYS = 01, 02, ETC. Page 43 AF - 1 B 17 16 2 3 4 - 655 S L 01 5 6 7 8 FH - XXX 9 10 1. Classification AF = Groups B-C-D & EEx d IIC T6 IP 66/67 T70° SF = Groups B-C-D & EEx d IIC T6 IP 66/67 T70° BM = Groups F-G 2. Cover B = Cover 3. Shell Style 17 = Receptacle for box or panel-mount 19 = Receptacle for NPT-mount 4. Shell Size 16 = Shell Size 16 20 = Shell Size 20 24 = Shell Size 24 28 = Shell Size 28 5. Insert 10 through 100 contacts; See Insert Code column in Insert Table below. 6. Gender S = Female (Socket) Insert P = Male (Pin) Insert 7. Contact Plating L = Standard Silver K = Gold over silver 8. Insert Keying Blank = Normal Key Alternate = See Key Positions column in Insert Table. 9. Hub Accessory See Junction Box Table Blank = Panel / 17 Style or NPT / 19 Style 10. Wire Lead Variation Receptacle, Junction Box Shell Size 16 = 1½” NPT Shell Size 20 = 2” NPT Shell Size 24 = 2½" NPT Shell Size 28 = 3” NPT D = Gold over nickel See Wire Length Table. Per customer requirements. Receptacle, Junction Box INSERT TABLE (Reference Pages 32 thru 36) SHELL INSERT CONTACT PIN SIZE 2 1 SIZE CODE KEY POSITIONS QUANTITY AWG (mm ) 10 #12 (4.0) 16 681 N+4 10 #12 / G (4.0) 16 676 N+1 19 #12 / G (4.0) 16 612 N+4 19 #12 (4.0) 16 677 N+1 19 #12 (4.0) 20 676 N+5 19 #12 / G (4.0) 20 688 N 19 #16 (1.5) 16 655 N+9 20 #12 (4.0) 20 632 N+3 20 #12 / G (4.0) 20 687 N+1 37 #12 (4.0) 20 686 N 37 #12 / G (4.0) 20 650 N+3 37 #16 (1.5) 16 621 N+9 55 #18 (.75) 16 640 N + 10 61 #18 (.75) 16 633 N+4 68 #16 (1.5) 20 613 N+4 100 #16 (1.5) 24 613 N+4 1. NORMAL KEY POSITION = N; ALTERNATE KEYS = 01, 02, ETC. Page 44 - Receptacle, Panel-Mount Receptacle, NPT WIRE LENGTH CODE LENGTH Inches Meters L12 12 0.31 L24 24 0.61 L36 36 Etc 0.91 Etc JUNCTION BOX SHELL SIZE CONDUIT HUB CONDUIT HUB LOCATION SIZE (Inches) 16 & 20 ‘F’ ‘H’ TOP & BOTTOM 1½ - 11½ NPT 24 ‘B’ BOTTOM ‘K’ 2½ - 8 NPT 28 ‘B’ BOTTOM ‘L’ 3 - 8 NPT Example: Suffix “-FH” denotes thru feed with a 1½ inch hub. AF - 1 D 10 16 2 3 4 - 621 P L 01 5 6 7 8 - XX 9 - XXX 10 1. Classification AF = Groups B-C-D & EEx d IIC T6 IP 66/67 T70° SF = Groups B-C-D & EEx d IIC T6 IP 66/67 T70° BM = Groups F-G 2. Cover Blank = No Cover 3. Shell Style 10 = Plug, Attachment 15 = Receptacle, Attachment 4. Shell Size 16 = Shell Size 16 20 = Shell Size 20 5. Insert 10 through 100 contacts. See Insert Code column in Insert Table below. 6. Gender S = Female (Socket) Insert P = Male (Pin) Insert 7. Contact Plating L = Standard Silver K = Gold over silver 8. Insert Keying Blank = Normal Key Alternate = See Key Positions column in Insert Table. 9. Grommet Replace XX with cable diameter code number from Page 37. TC = Tapped Conduit B = Basket Weave 10. Wire Lead Variation Plug, Conduit Tapped Receptacle, Conduit Tapped B = Cover / Receptacle D = Cover / Plug 24 = Shell Size 24 28 = Shell Size 28 D = Gold over nickel See Wire Length Table. Per customer requirements. INSERT TABLE (Reference Pages 32 thru 36) CONTACT PIN SIZE SHELL INSERT KEY 2 1 QUANTITY AWG (mm ) SIZE CODE POSITIONS 10 #12 (4.0) 16 681 N+4 10 #12 / G (4.0) 16 676 N+1 19 #12 / G (4.0) 16 612 N+4 19 #12 (4.0) 16 677 N+1 19 #12 (4.0) 20 676 N+5 19 #12 / G (4.0) 20 688 N 19 #16 (1.5) 16 655 N+9 20 #12 (4.0) 20 632 N+3 20 #12 / G (4.0) 20 687 N+1 37 #12 (4.0) 20 686 N 37 #12 / G (4.0) 20 650 N+3 37 #16 (1.5) 16 621 N+9 55 #18 (.75) 16 640 N + 10 61 #18 (.75) 16 633 N+4 68 #16 (1.5) 20 613 N+4 100 #16 (1.5) 24 613 N+4 1. NORMAL KEY POSITION = N; ALTERNATE KEYS = 01, 02, ETC. Plug, Attachment Receptacle, Attachment Note: Code logic is provided to identify features called out by standard part numbers. Not all component codes are compatible with all others. Reference part number tables under appropriate product sections of this catalog or consult Vantage Technology. Page 45 GD S 1 2 - D5 L 1 3 4 5 - 92 A N M E Q P 6 7 8 9 10 11 12 SINGLE 1. Classification 2. Controls GD = Class I, Groups B-C-D, 600 VAC, 60/400 Hertz EEx d IIC T6 IP 66/67 T70°, 1000 VAC / 500 VDC Omit if Not Required R = 1 red pilot + 1 push button switch S = 1 red and 1 amber pilot light + P = 1 red and 1 green pilot light + 2 push button switches 2 push button switches 3. Receptacle D5 = See Receptacle Table 4. Contact L = Crimp Type, Silver-plated / Standard 5. Insert Keying Omit for normal (N) key - See Receptacle Table 6. Box Style 92 = Single Receptacle 7. NPT Location Side A, B, C, D or E - See Conduit Location Drawing 8. NPT Size #1 Select from Code Symbol Table 9. NPT Size #2 Select from Code Symbol Table - Omit if Not Required 10. (11 and 12) Same as 7, 8, and 9 - If Required RECEPTACLE TABLE (Reference Pages 29 thru 32) AMPS 30 32 60 63 100 125 200 260 INSERT INSERT SYMBOL RECEPTACLE ASSEMBLY 2 POLE, 3 WIRE A1 GD-1716-51SL-L36 3 POLE, 4 WIRE A2 GD-1716-23SL-L36 4 POLE, 5 WIRE B1 GD-1720-36SL-L36 2 POLE, 3 WIRE B2 GD-1720-61SL-L36 3 POLE, 4 WIRE B3 GD-1720-40SL-L36 4 POLE, 5 WIRE C1 GD-1724-29SL-L36 2 POLE, 3 WIRE C2 GD-1724-60SL-L36 3 POLE, 4 WIRE C3 GD-1724-39SL-L36 4 POLE, 5 WIRE D1 GD-1728-23SL-L36 2 POLE, 3 WIRE D3 GD-1728-30SL-L36 3 POLE, 4 WIRE D4 GDU-1728-31SL-L36 5 POLE, 6 WIRE D5 GDT-1728-42SL-L36 (3P, 4W, 2 #10 relay contacts) 1. NORMAL KEY POSITION = N; ALTERNATE KEYS = 01, 02, ETC. KEY POSITIONS1 N+5 N+5 N+2 N+7 N+4 N+3 N+7 N+5 N+3 N+9 N+3 N + 10 CODE SYMBOLS – NPT SYMBOL 4 5 6 7 8 9 M N P Q Page 46 NPT SIZE ½” ¾” 1” 1 ¼” 1 ½” 2” 2 ½” 3” 3 ½” 4” CONDUIT LOCATION LETTERS If the first opening is to be omitted, use the letter 'O'. For example, AO9 will specify one 2" opening on side 'A' centered 11.5" off the bottom. GD DUPLEX - A1 B3 L 1 2 2 3 4 5 6 1 - 93 B 6 8 D 7 M 7 8 9 10 11 12 13 1. Classification GD = Class I, Groups C-D, 600 VAC, 60/400 Hertz EEx d IIC T6 IP 66/67 T70°, 1000 VAC / 500 VDC 2. Receptacle #1 A1 = See Receptacle Table 3. Receptacle #2 B3 = See Receptacle Table 4. Contact L = Crimp Type, Silver-plated / Standard 5. Insert Keying #1 Omit for normal (N) key - See Receptacle Table 6. Insert Keying #2 Omit for normal (N) key - See Receptacle Table 7. Box Style 93 = Duplex Receptacle 8. NPT Location Side A, B, C, D or E - See Conduit Location Drawing 9. NPT Size #1 Select from Code Symbol Table 10. NPT Size #2 Select from Code Symbol Table - Omit if Not Required 11. (12 and 13) Same as 8, 9, and 10 – If Required RECEPTACLE TABLE (Reference Pages 29 thru 32) AMPS 30 32 60 INSERT INSERT SYMBOL RECEPTACLE ASSEMBLY KEY 1 POSITIONS 2 POLE, 3 WIRE A1 GD-1716-51SL-L36 N+7 3 POLE, 4 WIRE A2 GD-1716-23SL-L36 N+5 4 POLE, 5 WIRE B1 GD-1720-36SL-L36 N+2 2 POLE, 3 WIRE B2 GD-1720-61SL-L36 N+7 3 POLE, 4 WIRE B3 GD-1720-40SL-L36 N+4 63 1. NORMAL KEY POSITION = N; ALTERNATE KEYS = 01, 02, ETC. CODE SYMBOLS – NPT SYMBOL NPT SIZE 4 ½” 5 6 ¾” 1” 7 8 1 ¼” 1 ½” 9 M 2” 2 ½” N 3” P 3 ½” Q 4” CONDUIT LOCATION LETTERS If the first opening is to be omitted, use the letter 'O'. For example, AO9 will specify one 2" opening on side 'A' centered 11.5" off the bottom. Note: Code logic is provided to identify features called out by standard part numbers. Not all component codes are compatible with all others. Reference part number tables under appropriate product sections of this catalog or consult Vantage Technology. Page 47 Circuit Breaking, Delayed Action Type Explosionproof, Class I, Groups C and D 20 or 30 Amperes 2 Pole, 3 Wire or 3 Pole, 4 Wire EPD Plugs and ER Receptacles, in addition to their regular function of making electrical connections to portable equipment, are current-rupturing devices which provide a safe and positive means for opening and closing electrical circuits. The contacts are confined within closed chambers to snuff the arc and are detained a sufficient length of time in their travel to permit cooling before exposure to the atmosphere. This is accomplished by the delayed action feature, which operates on the extremely simple straight-line principle illustrated schematically below. Contact units are factory-sealed in the receptacle housing at the terminal end therefore seal fittings are not required adjacent to the receptacle. Flexible lead wires are provided for connection to the circuit wires. Plugs and receptacles with a longer extra pole connect directly to the shell, completing the grounding circuit through the conduit system. The ground pole of the plug has a solder-less lug for connecting the extra conductor of the portable cord which is required by Article 500 of the N.E.C. for grounding non-current carrying metal parts of portable devices Listed plugs fit only receptacles of the same rating. Circuit Breaking, Delayed Action Operating Principle Page 48 Factory Sealed EPD PLUGS AND ERR RECEPTACLES CIRCUIT BREAKING WITH DELAYED ACTION Explosionproof Class I, Groups C and D ERR Receptacles ERR Two-Gang Receptacles EPD Plugs - Aluminum Alloy Plugs fit only receptacles of the same electrical rating as listed in the spaces directly to the left of each plug group. For Circuits Hub Positions Hub Size Receptacle Catalog Number Diameter Cord Plug Catalog Number .250 to .625 EPD-51532 .250 to .625 EPD-51542 20 AMPERE 20 Amperes or 1 HP, 120 or 240 Volts - 60 Hz A.C. 2 Pole 3 Wire 2 Pole 3 Wire Single Duplex Dead End ‡ ½ ¾ 1 ERRA-11532 ERRA-21532 ERRA-31532 ERRA-115322 ERRA-215322 ERRA-315322 Through Feed ½ ¾ 1 ERRC-11532 ERRC-21532 ERRC-31532 ERRC-115322 ERRC-215322 ERRC-315322 20 Amperes or 1 ½ HP, 120 or 240 Volts - 60 Hz A.C. 3 Pole 4 Wire 3 Pole 4 Wire Dead End ‡ ½ ¾ 1 ERRA-11542 ERRA-21542 ERRA-31542 ERRA-115422 ERRA-215422 ERRA-315422 Through Feed ½ ¾ 1 ERRC-11542 ERRC-21542 ERRC-31542 ERRC-115422 ERRC-215422 ERRC-315422 30 AMPERE 30 Amperes or 1 ½ HP, 120 or 240 Volts; 7 Amperes or ½ HP, 480 Volts - 60 Hz A.C. Dead End ‡ ¾ 1 ERRA-23032 ERRA-33032 ERRA-230322 ERRA-330322 Through Feed ¾ 1 ERRC-23032 ERRC-33032 ERRC-230322 ERRC-330322 2 Pole 3 Wire .375 to .625 .626 to .875 EPD-53032 EPD-73032 30 Amperes or 3 HP, 120 or 240 Volts; 7 Amperes or ½ HP, 480 Volts - 60 Hz A.C. Dead End ‡ ¾ 1 ERRA-23042 ERRA-33042 ERRA-230422 ERRA-330422 Through Feed ¾ 1 ERRC-23042 ERRC-33042 ERRC-230422 ERRC-330422 3 Pole 4 Wire .375 to .625 .626 to .875 EPD-53042 EPD-73042 ‡ Can be installed with hub at top or bottom, as covers are reversible. Dimensions: Height including hubs: 6 1/4" except 1" hub sizes which are 6 ½". Width: 3 ½" for single gang - 7 3/8" for two gang. Mounting Holes: 11/32" diameter on 5 ½" x 2 ½" centers. Depth from mounting surface to end of receptacle cover: 7 1/8" for 20 amperes - 8 3/4" for 30 ampere. See Page 52 for Part Number Code Logic. Page 49 Factory Sealed EPD PLUGS AND ERH RECEPTACLES CIRCUIT BREAKING WITH DELAYED ACTION Explosionproof Class I, Groups C and D ERH Receptacles ERH Two-Gang Receptacles EPD Plugs - Aluminum Alloy Plugs fit only receptacles of the same electrical rating as listed in the spaces directly to the left of each plug group. For Circuits Hub Positions Hub Size Receptacle Catalog Number Diameter Cord Plug Catalog Number .250 to .625 EPD-51532 .250 to .625 EPD-51542 20 Amperes or 1 HP, 120 or 240 Volts - 60 Hz A.C. 20 AMPERE 2 Pole 3 Wire 2 Pole 3 Wire Single Two-Gang Dead End ‡ ½ ¾ 1 ERHA-11532 ERHA-21532 ERHA-31532 ERHA-115322 ERHA-215322 ERHA-315322 Through Feed ½ ¾ 1 ERHC-11532 ERHC-21532 ERHC-31532 ERHC-115322 ERHC-215322 ERHC-315322 20 Amperes or 1 ½ HP, 120 or 240 Volts - 60 Hz A.C. 3 Pole 4 Wire 3 Pole 4 Wire Dead End ‡ ½ ¾ 1 ERHA-11542 ERHA-21542 ERHA-31542 ERHA-115422 ERHA-215422 ERHA-315422 Through Feed ½ ¾ 1 ERHC-11542 ERHC-21542 ERHC-31542 ERHC-115422 ERHC-215422 ERHC-315422 30 Amperes or 1 ½ HP, 120 or 240 Volts; 7 Amperes or ½ HP, 480 Volts - 60 Hz A.C. Dead End ‡ ¾ 1 ERHA-23032 ERHA-33032 ERHA-230322 ERHA-330322 Through Feed ¾ 1 ERHC-23032 ERHC-33032 ERHC-230322 ERHC-330322 30 AMPERE 2 Pole 3 Wire .375 to .625 .626 to .875 EPD-53032 EPD-73032 30 Amperes or 3 HP, 120 or 240 Volts; 7 Amperes or ½ HP, 480 Volts - 60 Hz A.C. Dead End ‡ ¾ 1 ERHA-23042 ERHA-33042 ERHA-230422 ERHA-330422 Through Feed ¾ 1 ERHC-23042 ERHC-33042 ERHC-230422 ERHC-330422 3 Pole 4 Wire .375 to .625 .626 to .875 ‡ Can be installed with hub at top or bottom, as covers are reversible. Dimensions: Height including hubs: 6 1/4" except 1" hub sizes which are 6 ½". Width: 3 ½" for single gang - 7 3/8" for two gang. Mounting Holes: 11/32" diameter on 5 ½" x 2 ½" centers. Depth from mounting surface to end of receptacle cover: 7 1/8" for 20 amperes - 8 3/4" for 30 ampere. See Page 52 for Part Number Code Logic. Page 50 EPD-53042 EPD-73042 Featuring an Interlocked Tumbler Switch Explosionproof and Dust-tight, Class I, Group D and Class II, Group G APPLICATION: Used as service outlets for portable electrical equipment in hazardous locations. CONSTRUCTION: Plugs cannot be inserted or withdrawn unless switch is open. Switch cannot be closed unless plugs are fully inserted. The extra pole of the receptacle is connected to the housing to complete the equipment ground circuit. Series Size NPT (inches) A (inches) B (inches) 1/2 3/4 1 21/32 25/32 7/8 5/8 17/32 17/32 YX Rust Proofed Ferrous Alloy Inside Clear Dimensions (inches) Length 2 15/16 2 15/16 2 15/16 Width 2 17/32 2 17/32 2 17/32 Depth 2 9/16 2 9/16 2 9/16 2 Pole, 3 Wire 30 Amp 250 Vac 1 HP 460 Vac 2 HP 240 Vac 3 Pole, 4 Wire 20 Amp 460 Vac 30 Amp 250 Vac 2 HP 240 Vac or 480 Vac Catalog Number Catalog Number Hub Size (NPT inches) YXA-13022-G YXA-13032-G 1/2 YXA-23022-G YXA-23032-G 3/4 YXA-33022-G YXA-33032-G 1 YXRL-113022-G YXRL-113032-G 1/2 YXRL-223022-G YXRL-223032-G 3/4 YXRL-333022-G YXRL-333032-G 1 PXD Series Plugs for YX Series Receptacles With Strain Relief Cord Grip Aluminum Alloy, Natural Finish 2 Pole, 3 Wire 30 Amp 250 Vac 1 HP 460 Vac 2 HP 240 Vac 3 Pole, 4 Wire 20 Amp 460 Vac 30 Amp 250 Vac 2 HP 240 Vac or 480 Vac Catalog Number Catalog Number Diameter Cord (inches) PXD-53032-G PXD-53042-G .250 to .625 PXD-73032-G PXD-73042-G .625 to .875 See Page 53 for Part Number Code Logic. Page 51 EPD - 1 3 30 3 2 2 3 4 5 1. Classification EPD = Explosionproof … Class I, Groups C and D 2. Cable Diameter Range 5 = .250” to .625” (15 Amp) 5 = .375” to .687” (30 Amp) 7 = .750” to .875” (15 and 30 Amp) 3. Rating 15 = 20 amps / 1 HP 15 = 20 amps / 1½” HP 3 pole, 4 wire at 120 or 240 Vac 30 = 30 amps / 1½HP 7 amps / 1½ HP 2 pole, 3 wire at 120 or 240 Vac 480 volts – 60 Hz 30 = 30 amps / 3 HP 3 pole, 4 wire at 120 or 240 Vac 480 volts – 60 Hz 4. Insert 3 = 2 pole, 3 wire 4 = 3 pole, 4 wire 5. Voltage 2 = 240 volts ER R A 1 2 3 2 pole, 3 wire at 120 or 240 Vac See rating specified above. - 2 30 3 2 2 4 5 6 7 8 1. Classification ER = Explosionproof Receptacle … Class I, Groups C and D 2. Types R = Angled (45˚) Receptacle 3. Style A = Single Hub C = Thru-feed Hub P = Panel-mount 4. Hub Size 1 = ½” NPT 2 = ¾” NPT 3 = 1” NPT 5. Rating 15 = 20 amps 2 pole, 3 wire at 120 or 240 Vac / 1HP 15 = 20 amps 3 pole, 4 wire at 120 or 240 Vac / 1½ HP 30 = 30 amps 2 pole, 3 wire at 120 or 240 Vac / 1½HP 7 amps at 480 volts / ½ HP 30 = 30 amps 3 pole, 4 wire at 120 or 240 Vac / 3HP 7 amps at 480 volts / 1 HP H = Straight (90˚) Receptacle 6. Insert 3 = 2 pole, 3 wire 4 = 3 pole, 4 wire 7. Voltage 2 = 240 volts See rating specified above. 8. Gang Style 2 = 2 Gang Receptacle Omit for single gang Note: Code logic is provided to identify features called out by standard part numbers. Not all component codes are compatible with all others. Reference part number tables under appropriate product sections of this catalog or consult Vantage Technology. Page 52 PXD - 1 5 30 3 2 2 3 4 5 - G 6 1. Classification PXD = Explosionproof Plugs Class I, Group D and Class II, Groups F and G 2. Cable Diameter Range 5 = .250” to .625” 7 = .625” to .875” 3. Rating 30 = 30 amps at 240 Volt AC for 2 pole 3 wire 2 HP at 240 Vac 1 HP 480 Vac 30 = 30 amps at 240 Volt AC for 3 pole 4 wire 20 amps at 480 Volt AC 2 HP at 240 Vac or 480 Vac 4. Insert 3 = 2 pole, 3 wire 4 = 3 pole, 4 wire 5. Voltage 2 = 240 volts 6. Grounding G = Grounded through shell and extra pole. YX A 1 2 - See rating specified above. 2 2 30 3 2 3 4 5 6 7 - G 8 1. Classification YX = Explosionproof Receptacles Class I, Group D and Class II, Groups F and G 2. Hub Style A = Top Hub RL = Right and Left Thru-feed Hubs 3. Hub Size 1 = ½” 2 = ¾” 3 = 1” 4. Hub Size Omit for top hub only 1 = ½” 2 = ¾” 3 = 1” 5. Rating 30 = 30 amps at 240 Volt AC for 2 pole 3 wire 2 HP at 240 Vac 1 HP 480 Vac 30 = 30 amps at 240 Volt AC for 3 pole 4 wire 20 amps at 480 Volt AC 2 HP at 240 Vac or 480 Vac 6. Insert 2 = 2 pole, 3 wire 3 = 3 pole, 4 wire 7. Voltage 2 = 240 volts 8. Grounding G = Grounded through shell and extra pole. See rating specified above. Note: Code logic is provided to identify features called out by standard part numbers. Not all component codes are compatible with all others. Reference part number tables under appropriate product sections of this catalog or consult Vantage Technology. Page 53 Vantage has a proud history of maintaining an employee base with extensive experience and training in connectors and hazardous locations. This provides you with not only the safest and most reliable products in the market, but the support and service our customers have come to know and expect. Field Support Vantage connectors are the most reliable available. They are designed with trouble-free field installation in mind. Our years of application support give us the expertise to assist your installation process. We understand your industry and can help assure you of the most efficient, safe and effective start-up. Design Vantage’s engineering and design staff combine stateof-the-art modeling and analysis software with years of expertise in electrical connector technology. Innovations in explosionproof products keep us ahead of the competition to provide you with the safest and most reliable systems today and tomorrow. Engineering Excellence On-site Support Haz-Loc Presentations The specification and installation of explosionproof products requires a robust understanding of the thermodynamic relationships between gases, dusts and electrical installations. Let Vantage present a rigorous training session on hazardous locations to your group. We will provide instruction on haz-loc theory and Divisional / Zonal (ATEX) requirements. Connector Systems Vantage goes beyond the manufacture of world class explosionproof connectors. We can assist in the design of your connector system and also deliver the system ready to install. Save on the total installed cost of your system by letting us procure, assemble and test it, all with on time delivery. We provide all required documentation. Haz-Loc Training Pre-Assembled & Ready to Install Sales Staff At Vantage, customer satisfaction is an integral ingredient of our quality system. Our sales staff monitors your order from its acceptance, through production right up to its final destination. We understand the pressures you are under – changes occur, schedules get reworked – Vantage works with you to get your order exactly as your requirements demand. Call us and let us show you what Vantage service can do for you. Customer Satisfaction Page 54 Vantage connectors have safely served industry for over forty years with unmatched reliability. Our connectors can be found throughout the Americas and worldwide, on land-based facilities or offshore drilling platforms, in aerospace, petroleum, process manufacturing, chemicals, mining and other industries. Let us know how we can meet your needs. Page 55 Illinois North Texas South Wisconsin East, Michigan UP The Klode Company SMR Gulf Coast Inc. The Klode Company Fritz Klode 9313 Glacier Ridge Richmond, IL 60071 Phone: 815-678-6700 Cell: 847-309-9000 Email: fritz@klodeco.com Ted Ballinger 13639 Aldine Westfield Road Houston, Texas 77039 Phone: 281-774-3757 Cell: 713-829-5630 FAX: 281-774-3744 Email: tballinger@smrgulfcoast.com Mary Miller 153 Pine Court Appleton, WI 54914 Phone: 920-830-1202 Cell: 414-254-3463 Email: mary@klodeco.com United Kingdom, Europe Corporate Office Sprancon Ltd. Vantage Technology LLC John Backhouse 2A, Sandtop Lane Blackfordby, Derbyshire. DE11 8AL England Phone: 44-1283-551360 Cell: 44-7900-054466 Email: johnbackhouse@sprancon.co.uk 4675 South Windermere Street Englewood, Colorado 80110 Phone: 303-761-2121 FAX: 303-789-4215 Email: Support@VantageXP.com Web Site: www.VantageXP.com Page 56 Explosionproof Connectors for Hazardous Locations Notice: Specifications are subject to change without notice. Contact Vantage Technology for the latest specifications. All statements, information and data given herein are believed to be accurate and reliable but are presented without guarantee, warranty, or responsibility of any kind expressed or implied. Statements or suggestions concerning possible use of our products are made without representation or warranty that any such use is free of patent infringement and are not recommendations to infringe any patent. The user should not assume that all safety measures are indicated or that other measures may not be required. Specifications are typical and may not apply to all connectors. © 2015 Vantage Technology 2/15 Page 57 NOTES 4675 South Windermere Street Englewood, Colorado 80110 Page 58 Phone: 303-761-2121 Fax: 303-789-4215 Email: Support@VantageXP.com Web Site: www.VantageXP.com Vantage Technology Explosionproof Connectors Vantage Technology LLC Englewood, Colorado USA Phone 303-761-2121 VantageXP.com