Building Management Controls & Peripherals Electrical, Panel Accessories & Cable Management TECHNICAL CATALOGUE VOLUME 3 E.C.Products Building Management Controls & Peripherals Welcome E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Welcome to this new E. C. Products Limited Technical Catalogue. Here you will find all the technical information, installation/connection details for our updated range of Building Management Controls and Peripherals as well as our range of Industrial Electrical Controls and Panel & Cable Accessories including AC Contactors, thermal overloads, miniature circuit breakers relays, and a range of accessories for installation. The price list attached is correct at the time of going to press but please check the website for the latest prices and any offers that may be available. E. C. Products Limited (ECP) are dedicated to providing you with the highest quality products at the most competitive prices and to ensure that the quality and price is maintained, we have worked very closely with our suppliers from throughout the World to bring you a very real alternative to your current provider of Peripherals and Control Gear. Our aim is to provide you with the best possible service and customer support. Many of the products you will find here are available for next day delivery from our extensive stock and we are always willing to offer assistance and technical support when you need it most. Also, if the product you require is not listed in this Catalogue, then a multitude of alternative products, sizes and colours can be provided to order within a short delivery period. Contact our office for details. Thank you for taking the time to look through this Catalogue, we would welcome the opportunity to become your preferred supplier of these products. Please contact us should you require further information about how we may be able to assist you. 2 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk AV-DP Differential Air pressure and Velocity Transmitter EP-TF72 Thermal Fuse GS-CMD5B Carbon Monoxide Sensor Page 6 Page 20 Page 27 R600 Protection Relays MIX18 Modbus & BACnet PAG Magnehelic Gauges Page 36 Page 48 Page 61 EBMPIR Batten Mount PIR LDP Liquid DP Switch TE-AL Anti– Ligature Sensor Page 52 Page 63 Page 74 TE LP Low Profile Sensors TE-ET Telescopic Sensor TS-ET2 Electronic Multi stage Thermostat Page 75 Page 76 Page 89 FA Panel Vetilation ENC DED Hinged Door Enclosure Xenon Beacons Page 105 Page 106 Page 119 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk New products E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 3 Contents E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 4 E.C.Products Building Management Controls & Peripherals Contents 4–20mA Temperature������������������81 Fan speed controllers�������������������12 Radiant temperature sensors�������� 73 Air pressure������������������������������� 57 Flying lead temperature sensors��� 77 RCBO�������������������������������������� 113 Air velocity���������������������������������� 5 Gas leak������������������������������������31 RCCB�������������������������������������� 112 Anti-ligature temperature sensors���74 Gas sensors������������������������������ 25 Relays & bases�������������������������� 34 Averaging temperature sensors�����75 Gas valves�������������������������������� 28 Room temperature sensors����������� 71 Ball valves��������������������������������� 96 Humidity����������������������������������� 69 Selector Switches���������������������� 116 Bespoke�����������������������������������107 Immersible temperature sensors�����76 Shoe valves������������������������������� 98 Busbar�������������������������������������120 Inverters������������������������������������ 33 Smoke detection������������������������ 32 Butterfly valves��������������������������� 97 IO modules������������������������������� 37 Solenoid valves�������������������������� 99 Button temperature sensors���������� 73 Isolators����������������������������������� 111 Strap-on temperature sensors������� 80 Cable��������������������������������������125 Lighting control�������������������������� 49 Telescopic temperature sensors�����76 Cable glands����������������������������120 Liquid pressure��������������������������� 62 Temperature charts��������������������� 82 Ceiling sensor���������������������������� 72 Low profile temperature sensors����75 Terminals��������������������������������� 121 Condensation sensors����������������102 Mains switch isolators���������������� 112 Thermostats������������������������������� 86 Contactors�������������������������������108 MCB��������������������������������������� 113 Thimble temperature sensors���������74 Contents������������������������������������� 4 MCB enclosures������������������������ 111 Thyristors����������������������������������� 65 Controllers���������������������������������� 8 Metering����������������������������������� 53 Timers��������������������������������������103 Current��������������������������������������14 Modbus IO modules������������������� 48 Water leak�������������������������������101 Damper actuators�����������������������18 Moror starters��������������������������� 110 Window temperature sensors������ 80 DIN Rail�����������������������������������120 Outside temperature sensors�������� 72 Wind speed�������������������������������� 7 Duct temperature sensors������������ 78 Overloads��������������������������������109 Wiring accessories��������������������123 Emergency���������������������������������19 Panel lamps������������������������������ 117 Xenon beacons������������������������� 119 Enclosures��������������������������������106 Power supplies��������������������������� 67 Zone valves����������������������������� 100 Fan coil controllers����������������������12 Pressure independent valves�������� 95 Fan coil valves��������������������������� 93 Push Buttons����������������������������� 114 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Duct Air Velocity Sensors AV Description Technical Specification The AV range of Air Velocity Sensors are designed to measure the air velocity in HVAC ducts and provide a linear 0...10Vdc output signal across the range. The unit operates on a thermal principle based upon the cooling effect from the air speed. Features •Economical air velocity sensors •0...10Vdc output •Choice of measuring range Part Code Description AV-4 Duct Air Velocity Sensor 0...4 m/s AV-8 Duct Air Velocity Sensor 0...8 m/s AV-16 Duct Air Velocity Sensor 0...16 m/s Power Supply:24Vac/dc Output Signal:0...10Vdc Accuracy: ± 1% at mid range at 20°C Response Time: < 2 seconds Probe: 8mm diameter aluminium x 200mm long Temperature:–10…+60°C Humidity: 0...80% RH Air velocity E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Air Flow Probes AV-FP Description Technical Specification The AV-FP range of economical air flow sensors sense differential (velocity) pressure of VAV units and other locations in main or branch ducts. Four different lengths allow selection of the sensor to yield accurate readings on terminal unit inlet diameters from 100mm to 500mm. The sensor operates by measuring the velocity pressure using a differential pressure transmitter such as the PA-LP. Mounting: Integral flange with gasket Connections: ¼” nipples for 3/8” OD polyethylene tubing Weight:31g Ambient: 0°C to 50°C Dimensions Features •Economical air flow sensors •Integral flange and gasket •Choice of four different lengths •Connections for ¼“ tubing •Ideal for VAV units Part Code Description Dim A Sensing points AV-FP1002 80mm air flow probe 80mm 1 set AV-FP1003 140mm air flow probe 140mm 2 sets AV-FP1004 195mm air flow probe 195mm 3 sets AV-FP1005 250mm air flow probe 250mm 4 sets T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 5 E.C.Products Building Management Controls & Peripherals Air velocity E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Multi-point Air Flow Probes AV-MP Description The AV-MP range of Air Velocity Pitot Tubes can be used with our ranges of Air Differential Pressure Sensors to calculate airflow in larger ducts or in areas of turbulent airflow. The units come in pairs suitable for duct sizes up to 2 metres (larger upon request). Features •Polished Stainless Steel or Grey ABS •Gaskets included for duct sealing •Push on connectors for 6mm ID PVC tubing •Use with DF or PA-LP range of Air DP sensors Description AV-MP600 Multi-point Velocity Probe - 600mm AV-MP700 Multi-point Velocity Probe - 700mm AV-MP800 Multi-point Velocity Probe - 800mm AV-MP1000 Multi-point Velocity Probe - 1000mm AV-MP1250 Multi-point Velocity Probe - 1250mm AV-MP1500 Multi-point Velocity Probe - 1500mm AV-MP1750 Multi-point Velocity Probe - 1750mm AV-MP2000 Multi-point Velocity Probe - 2000mm For ABS, add: /ABS Other sizes available to order Technical Specification Probe: Nipples: Flange: Lengths: Part Code 26mm Diameter Polished Stainless Steel or Grey ABS Plated brass to suit 6mm ID PVC tubing 52mm diameter Chromed cast Steel See part codes Transmitter For Air Velocity and Differential Pressure AV-DP Description Technical Specification The AV-DP Differential Pressure Transmitter is an extremely versatile transmitter for monitoring pressure and air velocity. This compact package is loaded with features such as field selectable English or Metric ranges, Adjustable damping of output signal and the option to select a square root output for use with pitot tubes and other similar flow sensor. Features •Field upgradeable LCD display •Five ranges available •Plug in Display Available •Selectable Air Velocity or Diff. Pressure Part Code Description AV-DP-100V Air DP Transmitter 25, 50, 100 Pa 0-10V AV-DP-100 Air DP Transmitter 25, 50, 100 Pa 4-20mA AV-DP-1250V Air DP Transmitter 250, 500, 1250 Pa 0-10V AV-DP-1250 Air DP Transmitter 250, 500, 1250 Pa 4-20mA AV-DP-2000V Air DP Transmitter 2kPa 0-10V AV-DP-2000 Air DP Transmitter 2kPa 4-20mA Measured Media:Air and non-combustible, compatible gases. Accuracy:±1% for 50, 100, 500, 1250 Pa, 2, 3, 5 kPa ±2% for 25, 250 Pa Stability: ±1% / year FSO. Temperature Limits: –18 to 66°C. Pressure Limits:6.8 kPa maximum operation; 68kPa, burst. Supply:10-35Vdc (2-wire); 17-36 Vdc or isolated 21.6-33Vac (3-wire). Output Signals: 4-20mA (2-wire); 0-10V (3-wire). Response Time:Adjustable 0.5 to 15 sec. time constant. Provides a 95% response time of 1.5 to 45 seconds. Zero & Span Adjustments:Digital push button. Current Consumption: 40 mA max. Display (optional): 4 digit LCD. Electrical Connections:1.5mm² Process Connections: 5 mm ID Tube Enclosure Rating: NEMA 4X (IP66). Mounting Orientation: Diaphragm in vertical position. AV-DP-3000V Air DP Transmitter 3kPa 0-10V AV-DP-3000 Air DP Transmitter 3kPa 4-20mA AV-DP-5000V Air DP Transmitter 5kPa 0-10V 6 AV-DP-5000 Air DP Transmitter 5kPa 4-20mA AV-DP-LCD Plug-in Display T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Wind Speed & Direction Sensor AV-WS Description Technical Specification The AV-WSD wind speed and direction sensor provides wind speed and direction measurements and converts those measurements into a potentiometric or pulsed output which can be read by a PLC or Building Management System. Features •Converts wind speed to a pulsed output •Zero bounce contact closure output Part Code Description AV-WSS Wind Speed Sensor AV-WSD Wind Speed & Direction Sensor Electrical conn: Flying lead 3m long Ambient temperature:–20°C/+70°C Dimensions: Height 280mm Protection:IP65 Weight:500g Wind speed output: 1 contact closure per 1.493m/s (zero bounce) Min. start speed: 0.5 m/s Accuracy:±2% Contact rating: 50W, 100Vdc max, 1A Direction output: 0-1KΩ for 0-357° Mechanical travel: 360° endless travel Electrical travel: 357° (±2°) Resistance tolerance:±3% Linearity tolerance:±0.5% Wind speed E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Wind Speed & Direction Sensor AV-WSD Description Features The AV-WSD combined Wind Speed and Direction sensor is manufactured from anodized aluminium alloy, UPVC and stainless steel with moulded polypropylene cups. The units are lightweight yet very robust. The sensors are designed to be mounted to a mast of between 30...50 mm diameter by means of a V-shaped clamp and bracket. This allows simple orientation to North using the compass provided; the only setting up required. Wind Direction is sensed by a precision conductive potentiometer which combines exceptionally long life with high sensitivity. Wind speed is derived from a Hall Effect solid state magnetic switch activated by magnets in the cup rotor running in precision stainless steel ball race and ‘Oilite’ bearings giving very high sensitivity and very long life. Part Code Description AV-WSD-10 Wind speed and direction sensor 0...10V AV-WSD-20 Wind speed and direction sensor 4-20mA T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 •Converts wind speed to a 0...10Vdc or 4-20mA output •Converts wind direction to a 0...10Vdc or 4-20mA output •Lightweight and robust Technical Specification Electrical connection: 4-core cable 25m supplied as standard Weight:250g Wind speed output: 0...10Vdc range 0...50m/s OR 4-20mA Accuracy:±5% Direction output: 0...10Vdc range 0...360° OR 4-20mA Mechanical travel: 360° endless travel Resistance tolerance:±5% E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 7 E.C.Products Building Management Controls & Peripherals Controllers E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 1 Channel Electronic Thermostat CAD-1DS Description Technical Specification The CAD-1DS is a DIN rail mountable single channel electronic thermostat compatible with Building Management Systems. The unit monitors air or liquid temperatures and controls one user programmable switching relay in response. Features •Wide temperature range •Night setback input •Heating or cooling function •Digital LED display with temperature •DIN rail mountable, small footprint 8 Part Code Description CAD-IDS 1 channel electronic thermostat CAD-POT Remote setpoint adjuster T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Input Supply: 24Vac/dc ±15% 35mA max. 230Vac 1VA Sensor Type: Any 10KΩ Type T sensor from our range Temp. Range: –5°C to +95°C Differential:1-10°C Output Signal: 1 x C/O relay contact 10(5)A @ 240Vac Mounting: DIN rail carrier 91 x 82 x 51 mm Terminals: Rising clamp suitable for 0.5-2.5mm² Ambient: –20°C to +50°C E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 2/8 Channel Electronic Thermostat CAD-2DS Relay Expansion Module CAD-XR2 Description Technical Specification The CAD-2DS is a DIN rail mountable single channel electronic thermostat compatible with Building Management Systems. The unit monitors air or liquid temperatures and controls up to eight user programmable switching relay in response. The CAD-XR2 is a DIN rail mountable two relay expansion module for use with CAD-2DS electronic thermostat to provide up to eight user programmable switching relays. Features •Wide temperature range •Night setback input •Heating or cooling function •Digital LED display with temperature •Adjustable stage and inter-stage differential •Use CAD-XR2 with CAD-2DS to expand outputs •DIN rail mountable, small footprint Input Supply: 24Vac/dc ±15% 150mA max. 230Vac 6VA Sensor Type: Any 10KΩ Type T sensor from our range Temp. Range: –5°C to +95°C Differential:1-10°C Output Signal: 2 x C/O relay contact 10(5)A @ 240Vac 6 x optional plug-in relays with CAD-XR2 Terminals: Rising clamp suitable for 0.5-2.5mm² Ambient: –20°C to +50°C Part Code Description CAD-2DS 2/8 channel electronic thermostat CAD-XR2 2 relay expansion module CAD-POT Remote setpoint adjuster Controllers E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Room Temperature Controller RTR-S Description Technical Specification The RTR-S series are proportional temperature controllers for room applications and are available with selectable internal or external sensor and both heating and cooling outputs. Units can be supplied with numerical scale setpoint adjustment or simple ±8K adjustment around a fixed setpoint. The RTR-S014/015 also includes a fan speed selector switch. Features •Choice of setpoint adjustment •Heating and Cooling outputs •LED indication Power Supply: 24Vac/dc Temperature Sensor: Internal or External PT1000 Control Range: RTR-S012/014: +5…+30°C RTR-S013/015: 21°C ±8 Outputs: 1 x heating and 1 x cooling 0...10V or 10...0V selectable Proportional Band: Internally adjustable +0.5…+3K Neutral Zone: Internally adjustable +1…+3K Current Consumption: max. 5 mA Enclosure: Pure White ABS Dimensions: 95 x 97 x 30 mm Electrical Connections: up to 2.5mm² via screw terminals Humidity: <90% RH, non-precipitating Protection:IP30 Part Code Description RTR-S012 Room temperature controller +5…+30°C RTR-S013 Room temperature controller 21°C ±8 RTR-S014 Room temperature controller +5…+30°C with fan speed switch RTR-S015 Room temperature controller 21°C ±8 with fan speed switch T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 9 E.C.Products Building Management Controls & Peripherals Controllers E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 2 channel Temperature controller CAD-PI Description Technical Specification The CAD-PI is a DIN rail mountable single (optionally up to 3) channel electronic proportional temperature controller. The unit monitors air or liquid temperatures and controls from one to three proportional analogue channels. Features •One proportional channel, two extra optional •Night setback input •Heating, cooling or both function •Digital LED display with temperature Part Code Description CAD-PI 1 channel temperature controller CAD-XM1 1 channel expansion module Input Supply: 24Vac/dc ±15% 75mA max. Sensor Type: Any 10KΩ Type T sensor from our range Temp. Range: –5°C to +95°C Span:1-20°C Output Signal: 1 x 0...10V proportional (2 more optional) Mounting: DIN rail carrier 114 x 82 x 60 mm Terminals: Rising clamp suitable for 0.5-2.5mm² Ambient: –20°C to +50°C Proportional & Integral Temperature Controller CR-PI Description Technical Specification The CR-PI DIN rail mounted controller is a compact and cost effective solution for monitoring air or liquid temperature. The units have two analogue outputs as standard, remote setpoint potentiometer input, temperature sensor input, low limit sensor input and setback input. The outputs can be used to control various terminal devices ie. damper motors, valve actuators, step controllers, relay modules, power controllers etc. Features •2 Analogue Outputs - Heating and/or Cooling •Proportional and Integral Control •Remote Setpoint option •Adjustable Setback •0-10V or 2-10Vdc Output •Adjustable Proportional band •Adjustable Integral time •Output Voltage can be displayed •Monitors Minimum & Maximum Temperatures •DIN rail mounting 10 Part Code Description CR-PI 2 channel temperature controller T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Power Supply: 24Vac ± 10% 24Vdc +10/–0% Power Consumption: Typical 40mA (approx 120mA when LCD in use) Inputs: Control Temperature: –10...110°C Low Temperature: –20...+ 20°C External Setpoint: 1...11K ohm Setback Volt free contact or Open collector Output Signal: 2 x 0...10Vdc or 2...10Vdc LCD Display: 2 Line 8 digit LCD Set Up Pushbuttons: Increase, Menu, Decrease Set Up Values: Setpoint: –10…+110°C Low Limit: Off, –20...+20°C Setback: 0...30°C Deadband: 0...30°C Proportional Band: 1...30°C Integral Time: Off, 1...500 secs Mode: Cool-Cool, Heat-Cool, Heat-Heat Setpoint: None, ±4°C, ±20°C Output Values: 0 to 10V, 2 to 10V Temperature Element:10K3A1 Dimensions: 82 x 68 x 47mm Weight: 85 gms Terminals: Terminals for 0.5 to 2.5mm2 cable Ambient Range: 0 to 50°C Country of Origin: United Kingdom E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Setpoint Adjuster SP10V Description Technical Specification The SP-10V is ideal for control of devices which require a 0-10V analogue signal. This can be used for commissioning purposes or for manual control between 0-100% Features Power Supply:24Vac/dc. Output Signal:0...10Vdc. Connection: 1.5mm Rising Cage Terminal Dimensions: 86 x 86mm Controllers E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH •Flush Mount on single gang box. •24Vac/dc power supply. •Control of multiple devices. •Standard finish white, other finishes available Part Code Description SP10V 0-10V Setpoint adjuster Setpoint Adjuster SP10K Description Technical Specification The SP-10K is ideal for control of devices which require a 1-11KΩ resistive signal. This can be used for commissioning purposes or for manual control. Output Signal:1-11KΩ. Connection: 1.5mm Rising Cage Terminal Dimensions: 86 x 86mm Features •Flush Mount on single gang box. •Passive device •Control of multiple devices. Part Code Description SP10K 1-11KΩ Setpoint adjuster T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 11 E.C.Products Building Management Controls & Peripherals Fan coil controllers Fan speed controllers E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 12 Fan Speed Controller FSC Description Technical Specification The FSC Fan Speed Controller is a compact, TRIAC based fan & motor control designed for HVAC markets. The unit can automatically control most single phase AC fans and motors via an analogue signal or temperature sensor. The units is available in a choice of current ratings and an optional DIN rail mounting kit or polycarbonate enclosure can be provided. Features •Temperature Sensor or 0...20mA/0...10Vdc control signal •Fan On/Fan Off threshold adjustable •Many selectable options Power Supply:95-250Vac Frequency: 47-64 Hz Current Ratings: See Part Codes below Control Signals: 20K Temperature Sensor 0...20mA or 0...10Vdc Fixed speed option also available Fixed Speed settings:27...99% Dimensions: 88.9 x 68.6 x 26.9/52.3 mm Enclosure dimensions: 130 x 130 x 100 mm Electrical Connections: up to 2.5mm² via screw terminals Ambient: –25°C…+70°C, <90% RH (rating will derate above 40°C) Protection: IP20 Floating/Modulating Thermostat SRE05 Description Technical Specification SRE05 floating/modulating thermostat is mainly used for air conditioning, heating and cooling systems. It uses a 10K NTC Temperature sensor, providing temperature control for Air conditioning and fan coil cooling/heating by means of a control signal When the thermostat is powered on or off, it will output a return signal to fully close the valve. Features •Auto-return function when powered on or off. •Power surge and instant pulse protection. •Overtime protection function. •LCD (with backlight) showing ambient temperature and state. •Percentage display corresponding to DC voltage output value (SRE05P & SRE05F). •Selectable external temperature sensor (NTC thermistor). •Cool/heat selection. •Fits standard one gang back box T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Temperature range:10-30°C Supply Voltage: 24Vac at 0.6VA (No load) Accuracy: +/- 0.5°C External Sensor:10K3A1 Dimensions: 86 x 86 mm Part Code Description SRE05P-24V Temperature Control 0-10V SRE05A-24V Temperature Control on/off SRE05F-24V Temperature Control Floating 150sec E: sales@ecproducts.co.uk W: www.ecproducts.co.uk E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Description Fan coil controllers Electronic Fan Coil Controller SRE06 Technical Specification For All Models SRE06 thermostats are mainly used in central air-conditioning and heating system. It provides temperature control for central air-conditioning fan coil cool/heat motorized valves or other actuating mechanism via a control signal which is produced by comparing actual measured temperature and the temperature setpoint. It can also control the fan blower of fan coil units and adjust the fan speed Accuracy:±0.5°C Control range:10°c...30°C Temperature sensor: NTC thermistor 10KΩ Operating temperature:0...55°C Storage temperature:10...60°C Ambient humidity: 90% rh maximum Features •Auto-return function when turn off or power on •Power surge and instant pulse protection •Large LCD shows the ambient temperature, state and air volume •With system switch and fan speed switch •Internal or external temperature sensor (NTC thermistor) •Cool/Heat shift (summer or winter) •With ABS fireproof plastic, compliance with UL-94 standard •With flexible installation and convenient wire-connection Model Specific Technical Specification SRE06A (Heat/Cool) SRE06B (Cool Only) SRE06C SRE06F SRE06P Power supply: AC24V AC230V AC24V AC230V AC24V AC230V AC24V AC230V Output: AC24V 1A AC230V 1A AC24V 1A AC230V 1A AC24V 1A AC230V 1A DC0-10V 10mA DC0-10V 5mA 5VA 0.6VA 5VA 0.6VA 5VA 0.6VA 5VA AC230V (2A) AC24V (2A) AC230V (2A) AC24V (2A) AC230V (2A) AC24V (2A) AC230V (2A) Power consumption: 0.6VA Fan voltage: AC24V (2A) Control range: – – – – >150s OR >300s (optional) – – Return time: – – – – Total runtime for valve in the same direction >150s (>300s), uses overtime protection state – – Part Code Description SRE06A-24 24V On/Off Thermostat - Heat or Cool SRE06A-230 230V On/Off Thermostat - Heat or Cool SRE06B-24 24V On/Off Thermostat - Cool only SRE06B-230 230V On/Off Thermostat - Cool only SRE06C-24 24V On/Off Thermostat - Heat & Cool SRE06C-230 230V On/Off Thermostat - Heat & Cool SRE06F-24 24V Floating Output Thermostat SRE06F-230 230V Floating Output Thermostat SRE06P-24 24V Modulating Output Thermostat SRE06P-230 24V Modulating Output Thermostat T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 13 E.C.Products Building Management Controls & Peripherals Current E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH AC Current Switches CSW Description Technical Specification The CSW series of AC current switches activate a normally open (NO) contact closure via a solid-state switch whenever the monitored primary circuit current exceeds a pre-set level. Models are available to switch various load types, feature integral LEDs to indicate device power and also the switch status and can be provided in solid or split core configuration. The CSW-Axx models include a multi-turn adjustment to set the trip threshold to the desired value and the CSW-Fxx models operate as a go/no-go status indicators with a factory set minimum threshold value. The switches can monitor up to 200 Amps continuous and feature an auto-range circuit to eliminate manual jumpers. All models are UL, CE and RoHS compliant. The CSW series current switches are accurate, reliable, easy to install and require less servicing than differential pressure switches, or flow switches. Power Supply: Setpoint: Output Switch: Hysteresis: Response Time: Enclosure Size: Enclosure Material: Conductor Hole Size: Operating Temperature: None: self-powered Solid core - 0.5A...200A Split core - 1.5A...200A (CSW-F fixed at 0.5A) Solid state 0.3A @ 135V ac/dc ASx2 1A @ 250Vac < 2% FS max. < 200 mS Solid core - 61 x 90 x 25 mm Split core - 63 x 100 x 32 mm UL 94V-0 flammability rated ABS Solid core - 19mm diameter Split core - 22.6 x 22.6 mm –25°C to + 70°C The CSW series current switches can be used to monitor devices with a maximum continuous operating current of up to 200 Amps and the power supply is induced from the conductor being monitored. All of these units come with an unconditional 5 year limited warranty. Features •Auto-ranging up to 200A •Power induced from monitored conductor •True digital switching and very low leakage •Choice of output rating •Fixed or adjustable setpoint •Five Year Warranty 14 Part Code Description CSW-NO-FSD Solid Core Fixed Setpoint Current Switch CSW-NO-FSP Split Core Fixed Setpoint Current Switch CSW-NO-ASD Solid Core Adjustable Setpoint Current Switch 0.3A @ 135Vac/dc CSW-NO-ASP Split Core Adjustable Setpoint Current Switch 0.3A @ 135Vac/dc CSW-NO-ASD2 Solid Core Adjustable Setpoint Current Switch 1A @ 250Vac CSW-NO-ASP2 Split Core Adjustable Setpoint Current Switch 1A @ 250Vac DRC Din rail clip T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Analogue Output Current Sensors CS Description Technical Specification The CS series current sensors monitor the current flowing to electrical equipment or buildings. The magnitude of this current is then converted into a linear 4-20mA or 0 to 10 VDC output signal, which can be monitored by a Building Management System. The units have jumper selectable input ranges. These current sensors should be used in load trending (current monitoring) type applications and are fast acting, accurate, reliable, and extremely easy to install. All of the current sensors come with a limited five year factory warranty Features •Jumper selectable current ranges •0...10Vdc or 4...20mA outputs •Version available for use with Variable Speed Drives Part Code Description CS-SD10L 0...10 Vdc Solid Core 0...10/20/50A CS-SD10 0...10 Vdc Solid Core 0...100/150/200A CS-SP10L 0...10 Vdc Split Core 0...10/20/50A CS-SP10 0...10 Vdc Split Core 0...100/150/200A CS-SD420L 4...20mA Solid Core 0...10/20/50A CS-SD420 4...20mA Solid Core 0...100/150/200A CS-SP420L 4...20mA Split Core 0...10/20/50A CS-SP420 4...20mA Split Core 0...100/150/200A Power Supply: 0...10Vdc output - Self-powered 4...20mA output - nominal 24Vdc supply Selectable Ranges: Low Range - 0...10/20/50A High Range - 0...100/150/200A Frequency: 40...100 Hz (VSD Version 10...400Hz) Insulation Class: 600Vac RMS Accuracy: ± 1% Response Time: 0.5 S Enclosure Size: Solid core - 61 x 90 x 25 mm Split core - 63 x 100 x 32 mm Enclosure Material: UL 94V-0 flammability rated ABS Conductor Hole Size: Solid core - 19mm diameter Split core - 22.6 x 22.6 mm Operating Temperature: –30°C to + 70°C Certification: CE, UL and RoHS Current E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH CS-SD420LT 4...20mA Solid Core 0...10/20/50A for use with variable speed drives CS-SD420T 4...20mA Solid Core 0...100/150/200A for use with variable speed drives DRC Din rail clip T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 15 E.C.Products Building Management Controls & Peripherals Current E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Current Switches CS-x Description Technical Specification The CS-x series current switches are available in a solid-core or split-core with Normally-Open (N/O) output configurations. All of these sensors will have a solid-state output with a fixed or adjustable trip point (setpoint). These current switches are ideal for providing status information on any type of AC current using equipment. The solid-vcore units are an excellent choice for new installations while the split-core versions are more suited to retrofit or existing installations. The CS-x current switches are accurate, reliable, easy to install, and require less servicing than differential pressure switches, flow switches and paddle wheels. A current switch can be used to monitor fan and pump status, motors, compressors, and any other electrical equipment for proper operation. A change in the operating current may indicate mechanical failure or that the unit has been turned off. These current switches can be used to monitor devices with a maximum continuous operating current of up to 250 Amps and will not need to be externally powered, since the power for the switch is induced from the conductor being monitored. Another great feature of these current switches is that they include “Status” LEDs that will indicate whether the current is above or below the fixed trip point. All of these units come with a unique 35 mm Din Rail mounting flange and an unconditional 5 year limited warranty. Power Supply: None - Self-powered Setpoint: CS-F - 0.5A CS-FL - 0.2A CS-FS - 2.5A CS-FSL - 1.5A CS-A - 1...250A CS-AL - 0.5...250A CS-AS - 3...200A CS-ASL - 2...200A Output Switch: 0.3A @ 200V ac/dc Current Range:0...250A Frequency:40...1kHz Isolation Voltage:1270Vac Enclosure Size: Solid core - 58 x 86 x 25 mm Split core - 68 x 86 x 28 mm Enclosure Material: UL 94V-0 flammability rated ABS Conductor Hole Size: 19.8mm diameter Operating Temperature: –15°C to + 40°C Certification: CE, UL and RoHS Features •Lowest Operating Trip Points in the Industry •LED Status Indication •Integral Din Rail Mounting Flange •Easy Installation, Non-Polarity Sensitive •Accepts up to a 350 MCM Cable •Operates up to 250 continuous Amps •Limited 5 Year Warranty •RoHS and WEEE Compliant 16 Part Code Description CS-F Solid core fixed setpoint current switch, NO, 0.5A trip point, 0...250A CS-FL Solid core fixed setpoint current switch, NO, 0.2A trip point, 0...250A CS-FS Split core fixed setpoint current switch, NO, 2.5A trip point, 0...250A CS-FSL Split core fixed setpoint current switch, NO, 1.5A trip point, 0...250A CS-A Solid core adjustable setpoint current switch, NO, 1A to 250A trip point, 0...250A CS-AL Solid core adjustable setpoint current switch, NO, 0.5A to 250A trip point, 0...250A CS-AS Split core adjustable setpoint current switch, NO, 3A to 200A trip point, 0...250A CS-ASL Split core adjustable setpoint current switch, NO, 2A to 200A trip point, 0...250A T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Analogue Output Current Sensors CTA/CTV Description Technical Specification The CTA/CTV Series current sensors monitor the current flowing to electrical equipment or buildings. The magnitude of this current is then converted into a linear 4...20 mA or 0...10Vdc output signal, which can be monitored by your Building Management, DDC, or PLC controller. All of these sensors have jumper selectable input ranges. These current sensors should be used in load trending (current monitoring) type applications. The solid-core units are an excellent choice for new installations while the split-core versions are more suited to retrofit or existing installations. The current sensors are fast acting, reliable, and extremely easy to install. No additional din rail mounting clips are necessary, due to the unique design of the integral din rail mounting flange. All of these current sensors are factory calibrated using an NIST Traceable standard and shipped with the jumper placed in the largest jumper selectable range. Power Supply: CTV - Self-powered CTE - +12...30Vdc Output: CTV - 0...10Vdc CTA - 4...20mA Accuracy:±1% Current Range: 0...250A (range as per code) Frequency:30...1kHz Isolation Voltage:1270Vac Enclosure Size: Solid core - 58 x 86 x 25 mm Split core - 68 x 86 x 28 mm Enclosure Material: UL 94V-0 flammability rated ABS Conductor Hole Size: 19.8mm diameter Operating Temperature: –15°C to + 40°C Certification: CE, UL and RoHS Current E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH The CTA units must be externally powered using a +12 to 40 VDC power supply while the CTV are self-powered inducing the supply from the monitored conductor. All of these current sensors come with a limited five year factory warranty. Features •Fast Response Time •Integral Din Rail Mounting Flange •Easy Wiring, Polarity Sensitive Output •Accepts up to a 350 MCM Cable •Operates up to 250 continuous Amps •Highly Accurate •5 Year Limited Warranty Part Code Description CTV-50 0...10Vdc solid core current sensor, 0...10, 0...20, 0...50 A CTV-250 0...10Vdc solid core current sensor, 0...100, 0...200, 0...250 A SCTV-50 0...10Vdc split core current sensor, 0...10, 0...20, 0...50 A SCTV-250 0...10Vdc split core current sensor, 0...100, 0...200, 0...250 A CTA-50 4...20mA solid core current sensor, 0...10, 0...20, 0...50 A CTA-250 4...20mA solid core current sensor, 0...100, 0...200, 0...250 A SCTA-50 4...20mA split core current sensor, 0...10, 0...20, 0...50 A SCTA-200 4...20mA split core current sensor, 0...100, 0...200 A T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 17 E.C.Products Building Management Controls & Peripherals Damper actuators E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 18 Belimo Damper Actuators Description Belimo damper actuators are suitable for motorised control of dampers in air ducts, they are available in wide range of torque ratings, voltages and control signals, available with built in SPDT auxiliary end switches. Additional auxiliary end switches can be added. Without switch c/w switch LM24A LM24A-S 5Nm Actuator 24Vac/dc open/close LM230A LM230A-S 5Nm Actuator 230Vac open/close NM24A NM24A-S 10Nm Actuator 24Vac/dc open/close NM230A NM230A-S 10Nm Actuator 230Vac open/close SM24A SM24A-S 20Nm Actuator 24Vac/dc open/close SM230A SM230A-S 20Nm Actuator 230Vac open/close GM24A 40Nm Actuator 24Vac/dc open/close GM230A 40Nm Actuator 230Vac open/close LM24A-SR 5Nm Actuator 24Vac/dc Modulating 0-10vdc NM24A-SR 10Nm Actuator 24Vac/dc Modulating 0-10vdc SM24A-SR 20Nm Actuator 24Vac/dc Modulating 0-10vdc GM24A-SR 40Nm Actuator 24Vac/dc Modulating 0-10vdc LF24 LF24-S 4Nm Actuator 24Vac/dc Spring Return LF230 LF230-S 4Nm Actuator 230Vac Spring Return NF24A NF24A-S2 10Nm Actuator 24Vac/dc Spring Return NF230A NF230A-S2 10Nm Actuator 230Vac Spring Return SF24A SF24A-S2 20Nm Actuator 24Vac/dc Spring Return SF230A SF230A-S2 20Nm Actuator 230Vac/dc Spring Return EF24A EF24A-S2 30Nm Actuator 24Vac/dc Spring Return EF230A EF230A-S2 30Nm Actuator 230Vac Spring Return GK24A-1 40Nm Actuator 24Vac/dc Super Cap Spring Return LF24-SR 4 Nm Actuator 24Vac/dc Modulating 0-10vdc Spring Return NF24A-SR 10 Nm Actuator 24Vac/dc Modulating 0-10vdc Spring Return SF24A-SR 20 Nm Actuator 24Vac/dc Modulating 0-10vdc Spring Return GK24A-SR 40 Nm Actuator 24Vac/dc Modulating 0-10vdc Spring Return S1A Auxiliary switch 1 x SPDT for use with LM, NM, SM, GM & GK S2A Auxiliary switch 2 x SPDT for use with LM, NM, SM, GM & GK S2A-F Auxiliary switch 2 x SPDT for use with LF, NF & SF T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Emergency Stop Buttons EP-EM Description Technical Specification The EP-EM1 range of emergency stop switches are for use in the manual shut down of systems in the event of fire or other emergency. Features Reset Type: Switch Rating: Housing Dimensions: EP-EM1, EP-EM1M, EP-EM1-S - Twist reset EP-EM1K, EP-EM1M-K - Key reset 10(6)A @ 240Vac SPDT 80 x 73 x 50mm Emergency E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH •Twist or key reset versions •Metal Boxed Versions •6A @ 230Vac rated Part Code Description EP-EM1 Emergency stop button - twist reset EP-EM1K Emergency stop button - key reset EP-EM1M Metal Boxed Emergency stop button - twist reset EP-EM1M-K Metal Boxed Emergency stop button - key reset EP-EM1-S Shrouded Emergency stop button - twist reset Electro Thermal Link EP-TL2 Description Technical Specification The EP-TL2 is for installing in a position where a fire hazard may occur, e.g. above boilers and interrupt the electrical supply to a gas valve or alarm. The link consists of a cast aluminium enclosure with a perforated cover having a temperature sensitive fuse. Switch Rating: 5A @ 240Vac SPDT Melting Point:72°C Housing Dimensions: 75 x 50 x 30mm Features •Pressed steel housing Part Code Description EP-TL2 Electro Thermal Link T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 19 E.C.Products Building Management Controls & Peripherals Emergency E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Thermal Fuse EP-TF72 Description Technical Specification The EP-TF72 Thermal fuse is for detecting boiler overheat and will cut the supply to a gas safety valve. It has been designed to give a faster response time than the conventional metal cased fuse, incorporating a 72°C thermal non-resettable fuse. The housing will withstand 150°C Features Electrical rating: 230V @5 Amp Switching Point:72°C Housing Material: Flame retardant Poycarbonate+20%GF Dimensions: 70mm Dia x 40mm Conduit Entry:20mm Electrical connection: Rising Clamp 0.5 to 2.5mm² cable •Robust Moulding •Easily accessible terminals •Fast response time •Well ventilated enclosure Part Code Description EP-TF72 Thermal Fuse 72°C Fireman’s Switch EP-FM Description Technical Specification The EP-FM1 Fireman’s Switch is for use in the event of fire or other emergency. Usually located at exits to gas plant rooms, units are key operated 3 position latching switches. A key guard with plastic window is available. Switch Rating: Keys: Connections: Dimensions: 6A @ 240Vac SPDT 2 supplied 4 x 100mm flying leads 86 x 86 x 50mm Features •3 position switch •Normal/Off/Extract •Supplied c/w two keys •6A @ 230Vac rated •Keyguard and replacement window available 20 Part Code Description EP-FM1 3 position fireman's switch EP-FMKG Key guard EP-FMW Replacement window for key guard EP-FMHC Hinged Cover T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Air Flow Switch FL-SL1E Description Technical Specification The FL-DBSL is a paddle switch intended to monitor air flow within a duct and provide a switched output on detection of either a specific air velocity or flow failure. Cut out Value: Min - 1.0 m/s, Max - 8.0 m/s Cut in Value: Min - 2.5 m/s, Max - 9.2 m/s Contacts: Dust-tight microswitch with SPDT contacts Switch capacity: 15 (8) A, 24...250 Vac Working: –40...+85 °C 10...90% r.h. (non condensing) Internal duct temp: –10...+85 °C Level:Brass Paddles: Stainless steel AISI 301 Housing: Galvanized steel sheet plate, ABS cover Storage: -40...+85 °C Protection: IP65 on the external duct side Size: 113 x 70 x 65 mm Weight: 630 g Features •Adjustable switching point •15A @ 230Vac rated •Stainless steel paddle Part Code Description FL-SL1E Air Flow Switch Flow & level E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Liquid Flow Switch FL-SF1K Description Technical Specification The FS1 paddle switch is intended to monitor liquid flow within pipes and provide a switched output upon detection of either a specific flow rate or flow failure. The unit screws directly into a 1” BSPT boss and has adjustable paddle lengths. Features •Adjustable switching point •15A @ 230Vac rated •Stainless steel paddle Part Code Description FL-SF1K Liquid Flow Switch T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Operating temp:–20°C/+110°C Materials: Paddle - Stainless steel Rod - Brass Encl. - Thermoplastic Protection:IP65 Switch rating: 15(8)A SPDT @ 230Vac Weight:670g Dimensions: 97 x 79 x 65mm (without paddle) E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 21 E.C.Products Building Management Controls & Peripherals Emergency E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Liquid Level Switch FL-SQ01 Description Technical Specification The FL-DBSQ is a float switch intended to monitor the liquid level in a tank or vessel and provide a switched output for local alarm, pump or valve control. The differential between switching is equivalent to approximately 14mm. The unit mounts into a 1” BSPT female boss. Access is not required to the inside of the tank. Features •1” BSPT mounting boss •15A @ 230Vac rated •Polypropylene float Mounting: 1” BSPT boss Operating temp: Ambient 0°C/+70°C Media 0°C/+110°C Materials: Float - Polypropylene Rod - Brass Bellows– Phosphor bronze Encl. - ABS Protection:IP65 Switch rating: 15(8)A SPDT @ 230Vac Weight:300g Switching diff.:14mm Part Code Description FL-SQ01-01 Liquid Level Switch - Brass Liquid Level Switch RFS Description Technical Specification Stainless steel level switch suitable for high or low level control Features •All Stainless Steel •High temperature up to 120ºC •Rugged hinge •Optional DIN Plug •½” thread •External fitting •Compact design 22 Part Code Description RFS-12P-2 Stainless steel level switch RFS REDUCER 1” adaptor T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Mounting: 1/2” BSPT Operating Temp:–40/120°C Material: Float Stainless Steel 316 Body Stainless Steel 304 Connection: Din Plug E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Level Switches FL-xMS Description Technical Specification A range of Level Switches designed for high and low liquid level detection in tanks and vessels. Units consist of a lever arm reed switch assembly and a tank fixing assembly. Units fit from the inside of the tank and tighten on to a back nut and are available for top or side mounting. Features •Low cost solution •Top or side mounted versions Technical Specification FL-SMS: Contact Form: Installation Dependant Switching Voltage Max. V: 240 Vac / 200 Vdc Switching Current Max. A:0.5 Carry Current Max. A:1.0 Switching Capacity Max. VA:50W Contact Resistance Max. mOhms:200 Lead Wire: XLPE AWG22 Reversible Switch Action:YES Operating Pressure Max. Kg/cm2:4.0 Operating Temperature Deg.°C: –20° +80° Material:Polypropylene Suitable Specific Gravity:0.75 Weight g:22 Mounting Hole Diameter mm:16.0 FL-TMS: Contact Form: Reversible Float Switching Voltage Max. V: 125 Vac Break Down 250 Vac Switching Current Max. A:0.5 Carry Current Max. A:1.0 Switching Capacity Max. VA: 10W SPST Contact Resistance Max. mOhms:200 Lead Wire: UL 1007 AWG22 PVC Operating Pressure Max. Kg/cm2:1.0 Operating Temperature Deg.°C: –20° +80° MaterialPolypropylene Suitable Specific Gravity:0.8 Weight g:12 Mounting Hole Diameter mm:10 Part Code Description FL-SMS Side Mounted Level Switch FL-TMS Top Mounted Level Switch Emergency E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Ultrasonic Level Sensor FL-ULS2 Description Technical Specification The FL-ULS2 is designed for level measurement in tanks or sumps and provides a 4-20mA output relating to the distance between the sensor and the surface being detected. Measurement is made by non-intrusive ultrasonic technology and the unit fixes in the top of the tank. Features •Non contact sensing •Pre-calibrated to set ranges •4-20mA output •IP68 housing •Built-in temperature compensation Part Code Description FL-ULS2 Ultrasonic Level Sensor T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Measuring range:0.5...8m Resolution:1mm Operating frequency:50kHz Accuracy: 0.25% of measuring range Output:4...20mA Supply:20...38Vdc Power consumption:0.5W Operating temperature:–10…+60°C Static pressure limits: –0.25...2 bar Materials: Casing Glass filled polypropylene Transducer UPVC Mounting flange: ANSI 3” 150lb, DN80 PN16 Protection:IP68 Dimensions: 178 x 192mm dia. Weight:2.42kg E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 23 E.C.Products Building Management Controls & Peripherals Emergency E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Capacitance Level Sensors FL-CAP Description Technical Specification These sensors are designed for level measurement in tanks or sumps providing a 4-20mA output relating to the level of fluid in the tank. The FL-CAP1 is suitable for conducting liquids such as water whilst the FL-CAP2 is designed for use with clean, low viscosity non-conducting liquids such as oil. Features •Suitable for a wide range of media •4-20mA output •No moving parts Output:4...20mA Supply:20...38Vdc Insertion length: 1 to 3m versions Process connection: 1” BSP Process temperature: 50°C max Ambient temperature:0...+60°C Display: 3½ digit 12mm Red LED Max. pressure: 20 bar @ 20°C Electrode insulation:Polypropylene Stem Material: 316 st. stl. Termination housing: Flameproof IP65 Protection: IP65 Conducting Liquids Non-conducting Liquids Description FL-CAP1-1.0 FL-CAP2-1.0 Capacitance Level Sensor - 1 metre FL-CAP1-1.5 FL-CAP2-1.5 Capacitance Level Sensor - 1.5 metres FL-CAP1-2.0 FL-CAP2-2.0 Capacitance Level Sensor - 2 metres FL-CAP1-2.5 FL-CAP2-2.5 Capacitance Level Sensor - 2.5 metres FL-CAP1-3.0 FL-CAP2-3.0 Capacitance Level Sensor - 3 metres Float Level Switch FL-11x Description Technical Specification The FL-11x sealed float switch is a switch which regulates the fluid level in a tank or well. The unit is water resistant and is capable of being used for oil, most acids and alkalis. The float contains a micro switch inside a water tight enclosure and is connected by a flexible cable. Operating temp:0...+70°C Protection:IP68 Switch rating: 10(8)A SPDT @ 250Vac Max. Pressure: 1 bar Dimensions: 97 x 79 x 65mm (without cable) Features •Adjustable switching point •Easy to install •Reliable and maintenance free 24 Part Code Description FL-113 Float Level Switch - 3 metre cable FL-115 Float Level Switch - 5 metre cable FL-118 Float Level Switch - 8 metre cable T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Space/Duct Air Quality Sensors xLQ Description Technical Specification The self-calibrating microprocessor-controlled duct air quality sensor is used to determine the air quality on basis of a mixed gas sensor/VOC sensor. It is used to measure the air quality for quantitative evaluation of room air pollution with contaminating gases. The air quality sensor does not trace concentrations of individual gases, but assesses the mixed gas concentration. Detectable gases: mixed gas, vapours of VOCs, cigarette smoke, automobile exhaust gases, human exhalation, combustion smoke (from wood, paper, plastics). The sensor‘s lifetime depends on the type of burden and gas concentration. Features Power supply: 24 Vac/dc, 70 mA at 24 V Sensor: VOC sensor (metal oxide) Measuring range: 0…100 % AQ; referred to calibrating gas Output signal: 0...10 V or 4...20 mA (selectable) Measuring accuracy: ± 20 % of final value Ambient temperature:0 ...+ 50 °C Electrical connection: 0.14 - 1.5 mm² screw terminals Response time: < 60s Enclosure: Duct or Space Mounting Protection type: Space - IP 30 Duct - IP65 Gas sensors E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH •Self-calibrating •Microprocessor controlled •Duct or Space Versions •Selectable output Part Code Description RLQ Space Air Quality Sensor - selectable output KLQ Duct Air Quality Sensor - selectable output Space Carbon Dioxide Sensor CO2-2000 Description Technical Specification Dual wavelength NDIR CO2 sensor providing either Digital, 0-10V or 4-20mA output. Dual wavelength technology provides enhanced long term stability and accuracy. The Dual wavelength optical measurement technology allows the CO2 sensor to maintain accuracy and stability even when subjected to shocks and vibrations. Selectable jumper for choosing either 4-20mA or 0-10V. Features •Dual Wavelength NDIR sensing method •Selectable ouput •Auto calibration function •Thermistor Option Available Part Code Description CO2-2000 Space Carbon Dioxide Sensor Response time: (63%) < 30 sec Measurement time interval:1.5 sec Ambient Temperature: 0ºC to 50ºC Ambient Humidity: 0ºC to 95% RH (Non-condensing) Gas flow rate: 0.2 to 1 m/sec Power supply (rectified): 16 to 24VDC Power Consumption: 70mA average Analog Outputs: 0-10VDC or 4-20mA Dimensions Space: 85 x 85 x 30mm Dimensions Duct: Housing: 120 x 80 x 53mm Probe: 24mm dia. x 160mm C02-2000-D Duct Carbon Dioxide Sensor T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 25 E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Space Carbon Dioxide Sensor CO2 Description Technical Specification This self-calibrating microprocessor-controlled CO2 measuring instrument is used for the detection of CO2 content in air within a range of 0 ppm to 2000 ppm CO2. Measuring signals are converted into standard signals of 0–10 V. The CO2 content of air is determined by an NDIR sensor. Features •Self-calibrating •Microprocessor controlled •0...10V output •Wall mounted •Option of 5 LED Indication Part Code Description RCO2 Space Carbon Dioxide Sensor - 0...10Vdc output RTM-CO2 Space Carbon Dioxide and Temperature Sensor Power supply: CO2 sensor: Measuring range: Output: Measuring accuracy: Pressure dependence: Long-term stability: Warm-up period: Ambient temperature: Electrical connection: Enclosure: Protection type: 24 V AC ⁄ DC optical sensor (NDIR) 0...2,000 ppm CO2 0...10 V ± 40 ppm, ± 5 % v.EW ± 1,6 % ⁄ kPa ± 1 % of final value per year 1 hour 0 …+ 50 °C 0.14 - 1.5 mm2 via screw terminals Wall Mounting IP 30 RTM-CO2-A Space Carbon Dioxide and Temperature Sensor c/w LED Indication Duct Carbon Dioxide Sensor A/CO2-D Description Technical Specification CO2 transmitters can be used in a broad range of applications including air quality monitoring in buildings. CO2 concentration levels in buildings are monitored to provide an indication of occupancy and to drive a ventilation control strategy. An effective DCV (Demand Controlled Ventilation) strategy will conserve energy and maintain indoor air quality. Features •Simple installation •Ideally suited for larger HVAC air ducts •Offers standard 0-10 volt output •Patented absorption infrared/gas sensing engine provides high accuracy in a compact low-cost package •Patented ABC Logic™ self-calibration system eliminates the need for manual calibration in most applications •Lifetime calibration guarantee 26 Part Code Description A/CO2-D Duct Carbon Dioxide Sensor - 0..10Vdc output T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Measurement Range: 0-2000 PPM factory calibrated Duct Air Velocity: 0 to 450 meter/min Temp Dependence: 0.2% of full scale per ºC Stability: <2% of full scale over the life of the sensor (15 years typical) Accuracy: ±40 ppm +3% of reading @ 22ºC (72ºF) when compared with factory certified reference Non-linearity: <1% of full scale @ 22ºC (72ºF) Pressure Dependence: 0.13% of reading per mm of mercury Response Time: 3 mins typical for a 90% step change Sampling Rate: Every two seconds, 25% duty cycle Warm-up Time: < two minutes (operational); 10 minutes to achieve max. accuracy Operating Conditions: Temperature: 0...50ºC Humidity: 0...95% RH, non-condensing Storage Conditions:–20ºC...70ºC Output: 0...10 Vdc Power Supply: 18...30 Vac, 50/60 Hz or 18...42 Vdc Dimensions: Probe Length: 10.46 cm Probe Diam: 3.14 cm Junction Box Depth: 4.06 cm Height: 7.62 cm E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Carbon Monoxide Sensor GS-CP01 Description Technical Specification The GS-CP01 is a fixed gas detector with high-quality electrochemical/catalytic gas sensor which has the advantages of good repeatability, long life-span and easy operation. It can monitor the gas concentration in air and output a 4-20mA signal. It is suitable for gas detection in car parking or industrial environment where toxic gas or combustible gas leaks. Versions are available for wall or duct mounting Features •0–500ppm •Analogue Output •High & Low Level Alarm Output •IP66 Protection •Wall or duct mounting versions Detection method:Electrochemical Range:0-500ppm Resolution:1ppm Low alarm level:35ppm High alarm level:200ppm Output:4-20mA Response time:<60s Shelf Life & life expectancy: > 2 Years Coverage: up to 400M² Supply voltage: 24Vdc +/-25% Ambient temperature range:–20°C to 50°C Dimensions: L165 x W118 x H62 Part Code Description GS-CP01 Wall Mount Carbon Monoxide Sensor GS-CP01-D Duct Mount Carbon Monoxide Sensor Gas sensors E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Carbon Monoxide Sensor GS-CMD5B1 Description Technical Specification The CMD Series carbon monoxide detector uses an electrochemical sensor to monitor the carbon monoxide level and outputs a 4-20 mA signal. The standard product features a 2-wire loop-powered output. Optionally, the device may be configured with an alarm relay and operates in 3-wire sourcing mode. Optional Modbus communications output is available. Features •Robust compact design •Optional alarm output •Modbus option •Long life expectancy Part Code Description GS-CMD5B1000 CO detector loop powered 4-20mA GS-CMD5B1100 Measurement:Electrochemical Sample Method:Diffusion Measurement Range: 0-300 ppm Accuracy: ± 5 ppm or ± 5% of reading @ 0-50˚C, 15-90% RH Agency Approvals: Sensor is UL Recognized for ANSI/UL-2034, UL-2075, E240671 Operating Conditions: –20-50˚C, 15-90% RH Stability: < 5% signal loss/year Response Time: < 35 seconds for 90% step change Life Expectancy: 5-7 years in air Typical Coverage Area:700m² or 15m radius Dimensions: 71 w x 104 h x 46 d mm Enclosure: ABS - UL94-V, IP65 Power Supply: 24 Vdc ±20% for 2 wire Loop powered 24 Vdc ±20% or 24 Vac ±10% with relay option CO detector, 4-20mA 3 wire, with relay output GS-CMD5B-MOD CO detector, Modbus T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 27 E.C.Products Building Management Controls & Peripherals Gas valves E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Electro-Hydraulic Gas Valves GV-PS Description Technical Specification GV-PS Auto Reset Electro-Hydraulic Gas Solenoid are used for the shutting off of gas supplies in the event of an emergency. This range is available in sizes from 1½“ up to 10” and are fitted with closed position switches as standard. Features •Manual reset switch available •EN161 approved •Sizes from 1½“ up to 10“ •Closed position switch fitted as standard 28 Part Code Description GV-PS6683 Electro-hydraulic Gas Valve - 1½” screwed GV-PS6684 Electro-hydraulic Gas Valve - 2” screwed GV-PS6685 Electro-hydraulic Gas Valve - 2½” screwed GV-PS6686 Electro-hydraulic Gas Valve - 3” screwed GV-PS6687F Electro-hydraulic Gas Valve - 4” flanged GV-PS6689F Electro-hydraulic Gas Valve - 6” flanged GV-PS66810F Electro-hydraulic Gas Valve - 8” flanged GV-PS66811F Electro-hydraulic Gas Valve - 10” flanged GV-PS-MRS Manual Reset Switch T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Operating Voltage: 240V @ 50Hz, -15%/+10% Operating Pressure: 200mbar max. Closure time: Max. 1 second Protection:IP54 Media: Non-corrosive gases and air Connections: Up to 3”: Screwed 4” and above: Flanged Materials: Die-cast aluminium Ambient: Operating temp: -15°C to +60°C Switch Rating: 5(2)A @ 250Vac/30Vdc Power Consumption:Opening: 200VA Fully open: 18VA E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Gas Solenoid Valves GV-VMR/GV-EVRM Description Technical Specification The VMR type valve is a fast opening single-stage solenoid valve, normally closed. This type of device is suitable for air or gas blocking and releasing controls, required in gas power burners, atmospheric gas boilers, furnaces and others gas consuming appliances. The VMR type valves are made in accordance with EN161 standards and the CE test certificate is issued from GASTEC (Pin 0063AQ1350) Features •1/2” to 6” pipes sizing. •G1/4” pressure gauge port •Closed position indicator •Fine mesh filter incorporated •Suitable for air and non-aggressive gases Connections: Threaded ISO 228/1 from Rp ½” to Rp 2” Flanged PN16 from DN65 to DN150 Voltage rating: 230 Vac 50/60 Hz Voltage tolerance: –15% / +10% Environment temp: –15°C / +60° C Max. working pressure:200 / 360 mbar Seal:NBR Opening/Closing time: < 1 sec. Protection class: IP 54 Cable gland:PG09 Auto reset Manual reset Description GV-VMR12 GV-EVRM12 Gas Solenoid Valve ½” screwed GV-VMR22/SW GV-EVRM22/SW Gas Solenoid Valve ¾” screwed GV-VMR32/SW GV-EVRM32/SW Gas Solenoid Valve 1” screwed GV-VMR352/SW GV-EVRM352/SW Gas Solenoid Valve 1¼” screwed GV-VMR42/SW GV-EVRM42/SW Gas Solenoid Valve 1½” screwed GV-VMR62/SW GV-EVRM62/SW Gas Solenoid Valve 2” screwed GV-VMR72/SW GV-EVRM72/SW Gas Solenoid Valve 2½” flanged GV-VMR82/SW GV-EVRM82/SW Gas Solenoid Valve 3” flanged GV-VMR92/SW GV-EVRM92/SW Gas Solenoid Valve 4” flanged GV-VMR932/SW GV-EVRM932/SW Gas Solenoid Valve 5” flanged GV-VMR952/SW GV-EVRM952/SW Gas Solenoid Valve 6” flanged GV-PCS-3 CPI Switch for ¾ & 1" Gas Valve GV-PCS-4 CPI Switch for 1¼&1½" Gas Valve GV-PCS-6 CPI Switch for 2" Gas Valve GV-PCS-8 CPI Switch for 2½&3" Gas Valve GV-PCS-9 CPI Switch for 4" Gas Valve GV-PCS-95 CPI Switch for 5 & 6" Gas Valve T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Gas valves E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 29 E.C.Products Building Management Controls & Peripherals Gas valves E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Gas Valve Auto Reset EVP-NCxxx Description Technical Specification The EVP valves are fast acting Gas Solenoid Valve, Normally closed, these are suitable for Gas safety applications to shut off gas supplies rapidly in Burners, boilers, furnaces and other gas consuming appliances. Features •Available for ½” to 8” pipe sizes •Threaded port for closed position switch •Suitable for air and non-aggressive gases •Gas interception automatic normally closed solenoid valves that open when the coil is powered and close when there is no tension. •These solenoid valves can be controlled by pressure switch, thermostat etc. •They can be equipped with a flow regulator and adjustable slow opening kit •Threaded Connections Part Code Description EVP-NC15 ½” Gas Valve Auto Reset Screwed EVP-NC20 ¾” Gas Valve Auto Reset Screwed EVP-NC25 1” Gas Valve Auto Reset Screwed EVP-NC32 1¼” Gas Valve Auto Reset Screwed EVP-NC40 1½” Gas Valve Auto Reset Screwed EVP-NC50 2” Gas Valve Auto Reset Screwed EVP-NC65 2½” Gas Valve Auto Reset Flanged EVP-NC80 3” Gas Valve Auto Reset Flanged EVP-NC100 4” Gas Valve Auto Reset Flanged EVP-NC125 5” Gas Valve Auto Reset Flanged EVP-NC150 6” Gas Valve Auto Reset Flanged EVP-NC200 8” Gas Valve Auto Reset Flanged EVP-030066 CPI switch for use with ½–¾” gas valve EVP-040066 CPI switch for use with 1“ gas valve EVP-060066 CPI switch for use with 1¼–1½“ gas valve EVP-070066 CPI switch for use with 2“ gas valve EVP-090066 CPI switch for use with 2½–3“ gas valve EVP-100066 CPI switch for use with 4“ gas valve EVP-11120066 CPI switch for use with 5–6“ gas valve Power Supply Voltage Tolerance:–15%..+10% Max Pressure: 200 or 360 mbar Environment Temperature: –15° +60° Max Superficial Temperature:85°C Protection Degree:IP65 Closing Time:<1s Opening Time:<1s 8” gas valve has built in CPI switch 30 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Gas Leak Detection GLD Description Technical Specification The GLD gas leak detection range is suitable for use in Boiler Rooms and other Commercial applications to provide safety and shut down functions in the event of gas leakage. Control units are available in 1, 2 or 3 channels for connection to 1, 2 or 3 remote sensors. They are mounted in DIN rail housings with the option of panel or wall mount enclosures. Output relays to operate auxiliary devices such as Solenoid Gas Valves or Sirens and fault remote signalling are fitted to all units. Power supply is 230Vac or 12-24Vdc and sensors are available for both Natural Gas, LPG/Propane and Carbon Monoxide. Features •1, 2 & 3 channel options •Audio & visual alarms •Adjustable alarm sensitivity •Relay output for gas valves •Relay outputs for remote alarms •Auto or manual reset Power Supply: Power Consumption: Relay Outputs: Pre-alarm Thresholds: Alarm Thresholds: Sensors: Materials: Ambient: Part Code Description GLD361 DIN rail Single Channel Gas Leak Detection Controller GLD651 DIN rail Single Channel Gas Leak Detection Controller GLD652 DIN rail Two Channel Gas Leak Detection Controller GLD653 DIN rail Three Channel Gas Leak Detection Controller GLD150 Natural Gas Sensor GLD250 Propane/LPG Sensor GLD350 Carbon Monoxide Sensor GLD644 Panel mount Kit for GLD651,652 & 653 GLD615 Wall mount kit for GLD651, 652, 653 GLD316 Panel mount Kit for GLD361 GLD315 Wall mount kit for GLD361 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 GLD361: 230Vac ±10% @ 50Hz GLD65*: 12V ±10% GLD361: 3VA GLD65*: 7VA GLD361: 5(1)A @ 250V SPDT GLD65*: 2 x 5(1)a @ 250V SPDT Natural Gas: 0.3% to 0.8% (3000 to 8000ppm) LPG: 0.14% to 0.35% (1400 to 3500ppm) CO: 0.012% to 0.03% (120 to 300ppm) Natural Gas: 0.5% to 1.25% (5000 to 12500ppm) LPG: 0.22% to 0.56% (2200 to 5600ppm) CO: 0.02% to 0.05% (200 to 500ppm) Natural Gas: GLD150 LPG: GLD250 CO: GLD350 Base: Nylon, Cover: ABS Storage: –25°C to +60°C Operating: 0°C to +45°C E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Gas leak E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 31 E.C.Products Building Management Controls & Peripherals Smoke detection E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Duct Smoke Detector SD-2000 Description The SL-2000 Series Smoke Duct Detector is the latest innovation for early detection of smoke and products of combustion present in air moving through HVAC ducts in Commercial, Industrial, and Residential applications. The unit is designed to prevent the recirculation or spread of smoke by air handling systems, fans, and blowers. Complete systems may be shut down in the event of smoke detection. The SD-2000 is designed and built to meet all local code requirements regarding HVAC supply and return duct smoke detectors. Output terminals are provided for a wide range of remote accessories such as horns, strobes, remote status indicators, and test/reset key switches or push buttons. The SD-2000 includes many features that represent true innovations from current generation duct smoke detectors. Our traditional installer/servicer-friendly approach has been closely followed and expanded throughout the SD-2000. This philosophy provides a new level of efficiency in after-purchase value to both the installer/servicer and end-user. Our attention to detail has yielded a host of “No-Tools Required” features, as well as a multi-application performance level as yet unmatched in the industry. Innovative product combined with unsurpassed customer service equals the right combination for all of your projects. The key features detail many of the customer-driven innovations incorporated in the SD-2000 Series. Features •Both models listed for high-temperature applications •Operating voltages: 230VAC, 115VAC, 24VAC, 24VDC •Interconnect up to 30 units for common functions •Patent pending “No-Tools Required” front or rear •loading and removing sampling/exhaust tubes •Patent pending “Test Port Valve” allows for aerosol smoke •testing without cover removal •Instantaneous cover removal trouble indication •Staggered terminal blocks for easier wiring •Flashing LED on detector head indicates normal operation •Magnet test capability (magnet included) •More wiring space than competitive models •Duct wall gaskets on back of enclosure are pre-installed •Reset switch is also an alarm test switch •Unit includes green pilot and red alarm visual indicators Part Code •External mounting tabs do not require cover removal to install •Colored cover gasket indicates proper cover seal •Compact, lightweight size means easy handling •Two sets of 10A form “C” alarm contacts •One set of 2A form “A” alarm contacts •One set of 10A form “C” trouble contacts •Large terminal connection screws •Standard interchangeable photoelectric or ionization heads •Complete wiring details permanently attached to unit Technical Specification Model Number: SD-2000-N Ionization SD-2000-P Photoelectric Sampling Tubes: STN-1.0 Sampling tube for 12” or less duct STN-2.5 Sampling tube for 6” to 2.5’ duct STN-5.0 Sampling tube for 2.5’ to 5.0’ duct STN-10.0 Sampling tube for 5.0’ to 10.0’ Power Requirements: 230VAC Standby 8 mA, Alarm 18mA 115VAC Standby 14 mA, Alarm 32mA 24VAC Standby 55 mA, Alarm 190mA 24VDC Standby 14 mA, Alarm 68mA Alarm Contacts Rating: 2 sets rated at 10 Amps @ 115VAC 1 set rated at 2 Amps Trouble Contacts Rating: 1 set rated at 10 Amps @ 115VAC Air Velocity: 100 to 4,000 ft./min. Ambient Temperature:0...60° Ambient Humidity: 10-85% RH Wiring: Solid or stranded: #12 to #22 AWG Material: Grey plastic backbox, clear plastic cover (Makrolon 94V-0) Dimensions: 13 ½” L x 4 ½” W x 2 ¼” H Weight: 2 ½ lbs. Hardware: 7” exhaust tube, sampling tube end cap, mounting template, test magnet and mounting hardware included Description SD-2000-N Duct smoke detector housing with ionisation sensor SD-2000-P Duct smoke detector housing with photoelectric sensor STN1 Sampling tube 1-2' STN2.5 Sampling tube 2-4' STN5 Sampling tube 4-8' STN10 Sampling tube 8-12' Please order Sampling Tubes separately 32 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Invertek Drive ODE-2-xxxxx-3KAxx Description Technical Specification Rich in features the Optidrive E2 is the most commercially competitive Optidrive in the Optidrive family. Innovative and compact the Optidrive E2 range combines good looks with robustness, reliability and easy to use performance. The product is dedicated to low power applications where total costs are ultra-competitive, including: •Optidrive E2 has only 14 standard parameters to adjust in its basic form, thus Optidrive’s legendary ease of use could not be easier or quicker to get started with. •Optidrive E2 can be supplied with or without an internal rfi filter Overload Capacity: 150% for 60 secs 175% for 2 secs Output Frequency:0…500Hz Input Frequency: 48–62Hz Voltage: 110–115 +/- 10% 1 Phase (0.5–1.5HP) 200–240 +/- 10% 1 Phase (0.37–4kW/0.5–5HP) 200–240 +/- 10% 3 Phase (1.5–3.7kW / 2–5HP) 380–480 +/- 10% 3 Phase (0.75–11kW/ 1–15HP) Inverters E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Features •Small mechanical envelope •Rugged industrial 50°C ambient rating for hot and tough applications •Simple mechanical and electrical installation •Simple operation, powerful features easy to use •Fast setup, factory default settings ok for most applications, only 14 basic parameters •Motor current and RPM indication Part Code Description ODE-0.75KW-IP20 Invertek Drive 0.75Kw 3 Phase IP20 ODE-1.5KW-IP20 Invertek Drive 1.5Kw 3 Phase IP20 ODE-2.2KW-IP20 Invertek Drive 2.2Kw 3 Phase IP20 ODE-4KW-IP20 Invertek Drive 4Kw 3 Phase IP20 ODE-5.5KW-IP20 Invertek Drive 5.5Kw 3 Phase IP20 ODE-7.5KW-IP20 Invertek Drive 7.5Kw 3 Phase IP20 ODE-11KW-IP20 Invertek Drive 11Kw 3 Phase IP20 ODE-0.75KW-IP66 Invertek Drive 0.75Kw 3 Phase IP66 ODE-1.5KW-IP66 Invertek Drive 1.5Kw 3 Phase IP66 ODE-2.2KW-IP66 Invertek Drive 2.2Kw 3 Phase IP66 ODE-4KW-IP66 Invertek Drive 4Kw 3 Phase IP66 ODE-5.5KW-IP66 Invertek Drive 5.5Kw 3 Phase IP66 ODE-7.5KW-IP66 Invertek Drive 7.5Kw 3 Phase IP66 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 33 E.C.Products Building Management Controls & Peripherals Relays & bases E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Relays and Bases Rx Description Features A range 2, 3 & 4 pole relays and bases in a choice of coil voltage. Technical Specification Dimensions (L x W x H): Number and type of contacts: Contact material: Max. switching voltage AC/DC: Min. switching voltage: AC1: DC1: Rated load Max. inrush current: Rated current: Max. breaking capacity AC1: Contact resistance: Max. operating frequency: Rated Coil voltage: Rated power consumption: At rated load AC1: No load: 50/60Hz, AC: DC: AC: DC: Insulation category: Insulation rated voltage: Rated surge voltage: Operating time (typical value): Release time (typical value): Electrical life resistive AC1: Mechanical life (cycles): Weight: Ambient temperature: Storage: Operating: Cover protection category: Vibration resistance: 34 •Choice of coil voltages •Complete with test flag •Optional LED R2 27.5 x 21.2 x 35.6 mm 2 C/O AgNi 250V/250V 5V 12A/250Vac 12A/24Vdc 24A 12A 3000VA ≤ 100mΩ 1200 cycles/hr 18000 cycles/hr See price table R3 27.5 x 21.2 x 35.6 mm 3 C/O AgNi 250V/250V 5V 10A/250Vac 10A/24Vdc 20A 10A 2500VA ≤ 100mΩ 1200 cycles/hr 18000 cycles/hr See price table R4 27.5 x 21.2 x 35.6 mm 4 C/O AgNi 250V/250V 5V 6A/250Vac 6A/24Vdc 12A 6A 1500VA ≤ 100mΩ 1200 cycles/hr 18000 cycles/hr See price table See price table 1.6VA 0.9W C250 250Vac 4000Vac AC: 10mS DC: 13mS AC: 8mS DC: 3mS ≥ 105 ≥2 x 107 35g –40…+85°C –40…+55°C IP40 5g 10...150 Hz See price table 1.6VA 0.9W C250 250Vac 2500Vac AC: 10mS DC: 13mS AC: 8mS DC: 3mS ≥ 105 ≥2 x 107 35g –40…+85°C –40…+55°C IP40 5g 10...150 Hz See price table 1.6VA 0.9W B250 250Vac 2500Vac AC: 10mS DC: 13mS AC: 8mS DC: 3mS ≥ 105 ≥2 x 107 35g –40…+85°C –40…+55°C IP40 5g 10...150 Hz 2 pole 3 pole 4 pole Description R2-12D-L R3-12D-L R4-12D-L Relay with Test Flag + LED 12VDC R2-24D-L R3-24D-L R4-24D-L Relay with Test Flag + LED 24VDC R2-24A-L R3-24A-L R4-24A-L Relay with Test Flag + LED 24VAC R2-110A-L R3-110A-L R4-110A-L Relay with Test Flag + LED 110VAC R2-230A-L R3-230A-L R4-230A-L Relay with Test Flag + LED 230VAC R2-T R3-T R4-T Standard Base R2-M R3-M R4-M Base with separate coil & contact circuits R-CLIP Retain/Eject clip for Rx-M/T bases T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Relays and Bases RMx Description Features A range 1 & 2 pole relays and bases in a choice of coil voltage. •Choice of coil voltages •12Vdc coil suitable for use with Trend BMS •Small footprint Technical Specification Dimensions (L x W x H mm): Number and type of contacts: Max. switching voltage AC/DC: AC1: DC1: Rated load: Max. inrush current: At rated load AC1: No load: 50/60Hz, AC: DC: AC: DC: Max. operating frequency: Rated Coil voltage: Rated power consumption: Electrical life resistive AC1: Mechanical life (cycles): Weight: Storage: Operating: Ambient temperature: Cover protection category: Vibration resistance: RM87 29 x 12.7 x 15.7 1 C/O 400V/300V 10A/250Vac 10A/24Vdc 20A RM85 29 x 12.7 x 15.7 1 C/O 400V/300V 16A/250Vac 16A/24Vdc 30A RM84 29 x 12.7 x 15.7 2 C/O 400V/300V 8A/250Vac 8A/24Vdc 15A 600 cycles/hr 600 cycles/hr 600 cycles/hr 72000 cycles/hr See price table See price table 0.75VA 0.25W ≥ 105 ≥3 x 107 14g -40…+85°C -40…+70°C IP40 10 g 10...150 Hz 72000 cycles/hr See price table See price table 0.75VA 0.4W ≥ 105 ≥3 x 107 14g -40…+85°C -40…+70°C IP40 10 g 10...150 Hz 72000 cycles/hr See price table See price table 0.75VA 0.4W ≥ 105 ≥3 x 107 14g -40…+85°C -40…+70°C IP40 10 g 10...150 Hz 1 pole 1 pole 16A 2 pole Description RM87-12D RM85-12D RM84-12D Miniature Relay 12VDC RM87-24D RM85-24D RM84-24D Miniature Relay 24VDC RM87-24A RM85-24A RM84-24A Miniature Relay 24VAC RM87-110A RM85-110A RM84-110A Miniature Relay 110VAC RM87-230A RM85-230A RM84-230A Miniature Relay 230VAC RM87-T RM84-T RM84-T Standard Base RM-CLIP Retain/Eject clip for RMx-T bases T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Relays & bases E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 35 E.C.Products Building Management Controls & Peripherals Relays & bases E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Phase Protection Relays Description Technical Specification The phase protection relay monitors phase failure, phase sequence and imbalance giving LED indication and volt free SPDT contact. Dimensions: 90 x 17.5 x 60mm Contact rating: N/O 5A, N/C 3A Power Consumption: 20VA max. Operating Voltage: 154 to 500Vac Phase failure Trip: <154 Volts Phase Imbalance 30 Volts Response Time: 200msec max. Operating Temp:0–50°C Features •3 wire input •LED Indication •Slim space saving design •Din rail mounting Part Code Description R600PSR Phase failure Relay Voltage Protection Relay Description Technical Specification The Voltage Protection Relay monitors phase sequence, under voltage and over voltage giving LED indication and a volt free SPDT contact. Features •3 wire input •LED Indication •Slim space saving design •Din rail mounting 36 Part Code Description R600VPR Voltage Protection Relay T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Dimensions: 90mm x 17.5mm x 60mm Contact rating: N/O 5A, N/C 3A Power Consumption: 20VA max. Operating Voltage: 170 to 290 Vac Under Voltage: 170 to 224 Vac Over Voltage: 236 to 290 Vac Trip Delay: 0.2 to 10 Seconds Operating Temp:0–50°C E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Single Relays & Bases IOR1 Description Technical Specification The IOR1 range of single relay modules are suitable for a wide range of voltages and are supplied complete with DIN rail mounting base and retaining clip. Features •DIN rail mounting base included •Choice of voltage •Retaining clip prevents relay falling out Contact Data Type of Contact: 1 x changeover contact Contact Material:AgNi Max. Switching Voltage:400Vac/300Vdc Min. Switching Voltage:5V Rated Load:12A/250Vac Max. inrush Current:20A Contact Resistance: < 100 mΩ Max. Operating Frequency:600 cycles/hour at rated load IO modules E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Coil Data Rated Voltage: See table Coil Resistance: See table Rated Power Consumption: AC - 0.75VA DC - 0.25W Operating Range: See table General Data Operating Time: Typical 7 ms Release Time: Typical 3 ms Ambient Temperature:–40°C…+85°C Dimensions: 75 x 15.5 x 67mm Coil Resistance Coil Operating Range at 20°C Part Code Description ±10% at 20°C Min Max IOR1-12DC 12Vdc Single Relay and Base 580Ω 9.0Vdc 36.0Vdc IOR1-24DC 24Vdc Single Relay and Base 1440Ω 16.8Vdc 61.2Vdc IOR1-24AC 24Vac Single Relay and Base 400Ω 19.2Vac 50Hz 28.8Vac 50Hz IOR1-230AC 230Vac Single Relay and Base 38500Ω 184.0Vac 50Hz 276.0Vac 50Hz M61G Plug in LED module with diode 6–24V M63G Plug in LED module with diode 110–230V Adjustable Single Relay Module IOVR1 Description Technical Specification The IOVR1 is a SPCO change over relay output from a 0 to 10Vdc with fully adjustable switch point. Features •DIN rail mounting •LED status indication •24 Vac/dc powered •Buffered 0 to 10V output Part Code Description IOVR1 Adjustable Single Relay Module T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Input Signal: Output Contacts: Power Supply: Hysteresis: Dimentions: 0...10Vdc 1mA min. into 22kΩ impedance 8A @ 230Vac (resistive load) 24Vac ±10% @ 50Hz or 24Vdc +15%/-6%, 65mA max. 5 or 10% link selectable 35 x 82 x 47mm E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 37 E.C.Products Building Management Controls & Peripherals IO modules E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Two Stage Relay Module IOR2 Description Technical Specification This IO module is used with DDCs to convert an analogue control input signal to a time proportional raise/lower, high/ low or binary relay output. Typically it is used to control valve and Damper actuators from an analogue signal. It is designed so that every status is clearly indicated with LEDs to facilitate operation and commissioning. Features •DIN rail mounting •Relay status LEDs indication •Link selectable raise/lower, hi/low or binary modes and time function •On/Off/Auto links for ease of commissioning Part Code Description IOR2 Two Stage Relay Module Input Signal: Output Contacts: Power Supply: Hysteresis: Operating Modes: LED Indication: Manual Override: Terminals: Ambient: Dimensions: 0...10Vdc 1mA min. into 22kΩ impedance 8A @ 230Vac (resistive load) 24Vac ±10% @ 50Hz or 24Vdc +15%/-6%, 65mA max. ±0.2Vdc about switching points Hi/Lo, Raise/Lower, Binary Green LED - Power Supply condition Red LED - Input Voltage condition On/Off/Auto jumper selectable Rising clamp 0.5-2.5mm² cable -10°C to +40°C, 0-80% RH non-condensing 52mm(H) x 62mm(W) x 83mm approx Three Stage Relay Module IOR3 Description Technical Specification This IO module is used with DDCs to convert an analogue control input signal to a time proportional raise/lower, high/ low or binary relay output. Typically it is used to control valve and Damper actuators from an analogue signal. It is designed so that every status is clearly indicated with LEDs to facilitate operation and commissioning. Features •DIN Rail mounting •Relay status LEDs indication •Link selectable binary, heat/cool, staged, sequenced •On/Off/Auto links for ease of commissioning •Built in timing for raise/lower applications 38 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Input Signal: 0...10Vdc 1mA min. into 22kΩ impedance Output Contacts: 8A @ 230Vac (resistive load) Power Supply: 24Vac ±10% @ 50Hz or 24Vdc +15%/-6%, 65mA max. Hysteresis: ±0.2Vdc about switching points Operating Modes: Binary, Heat/cool, Staged, Sequenced LED Indication: Green LED - Power Supply condition Red LED - Input Voltage condition Manual Override: On/Off/Auto jumper selectable Terminals: Rising clamp 0.5-2.5mm² cable Ambient: –10°C to +40°C, 0-80% RH non-condensing Dimensions: 52mm(H) x 62mm(W) x 83mm approx Part Code Description IOR3 Three Stage Relay Module E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Four Stage Relay Modules IOR4 Description Technical Specification This IO module is used with DDCs to convert an analogue control output to a binary, 2 x raise/lower, staged or sequenced relay output. LEDs indicate correct operation and low current draw from 0-10Vdc controller means that the IOR4 can work successfully with most BEMs controllers. Features •DIN Rail mounting •Relay status and fault finding LEDs indication •Link selectable binary, staged, sequenced •On/Off/Auto links for ease of commissioning Part Code Description IOR4 Four Stage Relay Module Input Signal: 0...10Vdc 1mA min. into 22kΩ impedance Output Contacts: 8A @ 230Vac (resistive load) Power Supply: 24Vac ±10% @ 50Hz or 24Vdc +15%/-6%, 65mA max. Hysteresis: ±0.2Vdc about switching points Operating Modes: Binary, 2 x raise/lower, Staged, Sequenced LED Indication: Green LED - Power Supply condition Red LED - Input Voltage condition Manual Override: On/Off/Auto jumper selectable Terminals: Rising clamp 0.5-2.5mm² cable Ambient: –10°C to +40°C, 0-80% RH non-condensing Dimensions: 52mm(H) x 89mm(W) x 83mm approx IO modules E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Six Stage Relay Modules IOR6 Description Technical Specification This IO module is used with DDCs to convert an analogue control output to a staged, reverse staged or sequenced relay output. LEDs indicate correct operation and low current draw from 0-10Vdc controller means that the IOR6 can work successfully with most BEMs controllers. Features •DIN Rail mounting •Relay status and fault finding LEDs indication •Link selectable staged, reverse staged, sequenced •On/Off/Auto links for ease of commissioning Part Code Description IOR6 Six Stage Relay Module Input Signal: 0...10Vdc 1mA min. into 22kΩ impedance Output Contacts: 8A @ 230Vac (resistive load) Power Supply: 24Vac ±10% @ 50Hz or 24Vdc +15%/-6%, 65mA max. Hysteresis: ±0.2Vdc about switching points Operating Modes: Staged, Reverse Staged, Sequenced LED Indication: Green LED - Power Supply condition Red LED - Input Voltage condition Manual Override: On/Off/Auto jumper selectable Terminals: Rising clamp 0.5-2.5mm² cable Ambient: –10°C to +40°C, 0-80% RH non-condensing Dimensions: 52mm(H) x 116mm(W) x 83mm approx IOR8 available upon request, POA T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 39 E.C.Products Building Management Controls & Peripherals IO modules E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Single Fixed Relay Module IOMR1 Description Technical Specification The IOMR1 is designed to provide a manual override of the output from a BMS Controller (or similar) and is particularly useful for commissioning or temporary control applications. The IOMR1 can also be used as an alternative to the IOR1-12DC relay module, with the added advantages of ON/OFF/AUTO Links The unit has a fixed switchpoint at 6V. Features •0/10 Vdc Input •Fixed switchpoint at 6Vdc •24V ac or dc powered •Complete with DIN carrier •ON/OFF/AUTO links for commissioning •LED indication Supply Voltage: 24V ac or dc Input Signal:0/10Vdc Switchpoint.:6Vdc Output contacts: 1 x SPCO Rating: 12A @ 230Vac LED Indication: ON when relay is energised Ambient: 0°C to 40°C/5-90% RH Storage:0/+50°C Terminals: Rising clamp 0.5-2.5mm² cable Dimensions: 76mm(H) x 23mm(W) x 45mm approx Country of Origin: United Kingdom Part Code Description IOMR1 Single Fixed Relay Module Four Channel Relay Override Module IOMR4 Description Technical Specification The IOMR4 is designed for applications which require independent manual override of digital output channels from BMS Controllers. The outputs can be switched without a controller being present which makes the IOMR4 useful for temporary control or commissioning. Link selection enables up to 4 outputs to be switched from Input 1. High Quality Rising Clamp Terminals are used for all connections. The IOMR4 is powered by 24V ac or dc and features LED indication of Power ON and LED indication for each energised relay. The IOMR4 is designed to mount on TS35 section DIN Rail. Input Signal: Must Operate: Output Contacts: Contact Rating: Power Supply: Manual Override: Terminals: LED Indicators: Ambient Range: Dimensions: 4 x 0-10V dc, (2mA typical) 5V dc 4 x SPCO 12A/250V ac (res.) 24V ac or dc +/-10% ON/OFF/AUTO (Link Selectable) Rising Clamp for 0.5-2.5mm2 Cable ON when relay energised 0 to 50’C 78mm x 92.5mm x 48mm approx. Features •4 x 0-10V dc Input •4 x SPCO Relay Outputs •On/Off/Auto Override •High Quality Rising Clamp Terminals •DIN Rail Mounting (TS35) •LED Indication Part Code Description IOMR4 40 Four Channel Relay Override Module T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Four Channel Digital Input Multiplexer IOD4 Description Technical Specification The Digital Input Expander allows 4 volt free inputs to be monitored by a single analogue input channel. The resultant analogue value can be decoded by the A to D function module in an BMS controller to produce internal digital status bits for alarm monitoring or other status input applications. Features •Expand capacity of existing ddc for cost effective installation. •Visual indication of LED inputs for easy commissioning •Application includes monitoring status of equipment Supply voltage: Supply current: Input Channels: Input Threshold: Distance: Output: I: V: LED: Dimensions: Ambient limits: 24Vdc or Vac ± 15% 50mA max (I mode) 30mA max (V mode) 4 volt free contact switch 24Vdc Upper 17.5V max (ON) level Lower 7.5V min (OFF) level Max. distance of IOD4 from controller 25m (V mode) 1000m (I mode) Mode selectable by link header current/voltage (I/V) 0 to 20mA, max. resistance of load 250Ω 0 to 10Vdc, max. current 1mA Single LED per input channel, LED on indicates contact closed 68 x 83 x 53mm Storage: –10°C to +70°C Operating: –10°C to +50°C Humidity: 0 to 90% RH non-condensing Part Code Description IOD4 Four Channel Digital Input Multiplexer IO modules E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Six Channel Digital Input Multiplexer IODIM6-MI Description Technical Specification The IODIM6-MI multiplexes 6 VFC or 24Vac/dc signals into a single analogue output. 0-10Vdc, 2-10Vdc or 4-20mA, and 0-20mA output variants are available making the unit compatible with a large range of BMS equipment. The input registers as active when the contact is closed. Additionally, jumpers are fitted to allow each input to be manually overridden for commissioning and testing purposes. The output sequence can also be reversed as required by some types of controller and control strategies. Features •6 x VFC or 24Vac/dc inputs Inputs: 6 x Volt free contacts or 24Vac/dc input signals Output: Voltage, 0-10Vdc at maximum load 10mA (2-10Vdc link selectable) Current, 4 to 20mA (link selectable 0-20mA), max resistance of load 500Ω LED Indication: ON when Input is ON Power Supply: 24Vac or dc (+/-15%) Power Consumption:24Vdc 40mA Max 24Vac 60mA max Terminals: Rising Clamp for 0.5-2.5mm2 Cable Ambient Temp:0-50°C Dimensions: 75 x 68 x 45mm (max.) •Reverse Action •Voltage and Current Output Variants •DIN Rail Mounting •Operates From 24Vac or dc Power Supply •LED Input Status Indication Part Code Description IODIM6-MI-V 6 Digital Input Multiplexer - Voltage Output IODIM6-MI-I 6 Digital Input Multiplexer - Current Output •Input Simulation T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 41 E.C.Products Building Management Controls & Peripherals IO modules E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 10 Channel Alarm Integrator IO-ALM10 Description Technical Specification The IO-ALM10 series of Alarm Integrators monitor up to 10 Input Channels and provide a relay output in the event of an alarm signal appearing on any one or more inputs. The IO-ALM10 Alarm Integrators are self-powered from the alarm input and are designed for mounting on TS35 section DIN rail. Features •10 input channels •1 x SPCO Relay Outputs •Self powered •DIN Rail Mounting (TS35) •24Vac/dc, and 230Vac versions available Alarm Inputs: Output: Contact Rating: Power Supply: Terminals: Dimensions: Ambient Temperature: Part Code Description IO-ALM10-24 24Vac/dc 10 Channel Alarm Integrator Module IO-ALM10-230 230Vac 10 Channel Alarm Integrator Module IO-ALM10-24 - 10 x 24Vac/dc IO-ALM10-230 - 10 x 230Vac 1 x SPCO Relay 12A@230Vac (resistive) Self-Powered from Input Rising Clamp for 0.5-2.5mm2 cable 55 x 75 x 48mm approx. 0 – 50°C Volt Free To Voltage Converter IOFS24-10 Description Technical Specification The IOFS24-10 has been designed to give 3 dc voltages using volt free inputs, the outputs can be adjusted between 0 and 10 volts. This Module can be used for switched fan speed control where a 0-10 volt signal is needed but only 3 set speeds are needed. Output: 3x adjustable dc voltages Supply Voltage: 24Vac/dc +/- 10% Termination: Rising Clamp for 0.5 to 2.5mm² Cable. Ambient: –10 to +50°C Dimensions:47mm(W)x49mm(D)x93mm(H) Features •Din rail mounting •Power on LED indication •24Vac/dc Supply •Adjustable outputs via multi turn trimmer 42 Part Code Description IOFS24-10 Volt Free To Voltage Converter T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Multi Input Remote Alarm CAD-AP Description Technical Specification A versatile audible/visual alarm point accepting a wide range of input triggers and selectable audible alarms. Features •Multi-Mode Operation •Triggers on 24vAC/DC, 240vAC or 0-10v Input •Rising or Falling Alarm feature on 0-10v Input •Delay Timer •High Intensity LED for Visual Indication •User Selectable Audible Alarm with Mute •Surface or flush mounting Part Code Description CAD-AP Multi input remote alarm panel Input Supply: Input Triggers: Output Signals: Mounting: 24V AC/DC 18mA 24V AC/DC, 240vAC, 0-10v Analogue Input 1 x Visual High-Intensity LED 1 x Audible Piezo Sounder Standard 1 Gang back box IO modules E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Multi Input Monitoring Panel IO-MPA12 Description Technical Specification The IO-MPA12 provides audible and visual status indication of up to 12 monitored points. The front panel gives visual and audible local alarm with mute and the option to connect remote alarm and mute function. The labelling can be done by the user making this an ideal solution for many applications. The inputs can be configured to operate on normally open or normally closed volt free inputs with option of 2 voltage inputs. Features •Configurable I/O can be set to alarm on normally open or normally closed condition •Local mute facility with visual “alarm muted” indication •Connections for remote alarm indication and mute facility •10 Volt free inputs and 2 x 24 volt inputs Part Code Description IO-MPA12 Multi input monitoring panel T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Power Supply:100-240Vac Current Rating: 0.55A max Connectivity:10 x VFC Alarm Inputs: 24Vdc @ 20mA 2 x Relay Alarm Inputs: 24Vac/dc max Common Alarm Output: 24Vdc 50mA max Alarm lamp Output: 24Vdc 50mA max Muted Lamp Output: 24Vdc 50mA max Remote Buzzer Output: 24Vdc 50mA max Remote Mute Button: 24Vdc @ 20mA Operating Temperature: 0°C to +50°C Enclosure Rating: IP54 Dimensions (WxHxD): 360 x 200 x 150mm E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 43 E.C.Products Building Management Controls & Peripherals IO modules E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Raise/Lower to Analogue Module AUD Description Technical Specification The AUD converts a floating point signal into a linear analogue output. There are two inputs on the AUD, one to increase the analogue output and one to decrease the analogue output. The output of the AUD is stable when the inputs are both off. A contact closure or voltage signal to either input will cause the output of the AUD to begin to ramp either up or down depending on which input was activated. If both inputs are “ON” the output will reset to the lowest value of the selected range. Features •Field Selectable Rate of Change •Field Adjustable Output with Manual Override Potentiometer •255 Step Resolution •Current or Voltage Output •LED Status Indicators •No Wrap Around •Relay, Transistor, or Triac Input Part Code Description AUD Raise/Lower to Analogue Output Module Supply Voltage: 24...35Vdc or 21.6...28Vac 50/60 Hz Supply Current: 208 mA max Signal Source: Relay contact closure, transistor or triac Signal Trigger Level: Normal Mode: 5 to 26.4 VDC 24 to 26.4 VAC Triac Mode: 24 to 26.4 VAC Range Rates of Change:45, 60, 120, 240 seconds Voltage Preset Ranges: Dip Switch Selectable: 0...1Vdc, 1...2Vdc, 0...4Vdc, 1...5Vdc, 0...10Vdc, 1...11Vdc, 0...13Vdc, 1...14Vdc Voltage Ranges: Adjustable 0...20Vdc Voltage Output Load: 3300 ohms minimum at 20 Volts ± 10% 400 ohms minimum at 10 Volts ± 10% Current Preset Ranges: Dip Switch Selectable: 0...16mA, 4...20mA Current Ranges: Adjustable 0...20mA Current Output Load: 0 to 750 ohms maximum. Accuracy: +/- 3% of span for adjustable ranges Resolution: 256 steps (all ranges) Power Output (for user): 24 VDC (+/- 10%), 48mA maximum Dimensions: 3.75” L x 2.25” W x 1.15” H Weight: 1.5 oz. Mounting: DIN rail mounted Operating Temperature:0...70°C Storage Temperature:–20...80°C Operating Humidity: 10% to 95% non-condensing Analogue Rescaling Module ARM Description Technical Specification The ARM analogue rescaling module accepts voltage or current inputs and rescales them to voltage or current outputs. A range of preset values are link selectable and fine adjustments can be made using trim potentiometers. The ARM can also reverse the signal. Units are supplied in a DIN rail mounting housing. Features Input signals: Ambient range: Output signals: Power supply: Dimensions: 0 to 35Vdc 0 to 44mA –10°C to +50°C 0.25 to 20Vdc 1 to 44mA 24Vac/dc @ 200mA max. 94 x 55 x 26mm •Field selectable ranges •Reverse or normal output •Factory calibrated •LED power indication •DIN rail mounting 44 Part Code Description ARM Analogue Signal Rescaling Module T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Voltage to Current Conversion Module IO-VI Description Technical Specification The IO-VI module will convert a 0-10Volt signal to 4-20mA current output. Din rail mounting with rising clamp terminals 24Vac/dc supply. Input Signal:0-10Vdc Output Signal:4-20mA Power Supply: 24Vac +/- 15%@<70mA 24Vdc +15%/-10%@<30mA Input Load: 100KΩ (I<0.1mA) approx. Output Load: 500Ω Max Terminals: Rising Clamp for 0.5 to2.5mm² Cable Ambient Temp:0-50°C Dimensions: 34mm(W) x 82mm(H) x 43mm Features •Power supply 24Vac/dc •0-10Vdc Input •4-20mA Output •Din Rail Mounting •No scaling Necessary Part Code Description IO-VI Voltage to mA Conversion Module IO modules E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Max, Min, Average Module IO6N1 Description Technical Specification The IO6N1 is a microprocessor controlled interface designed to provide maximum flexibility with a minimum of cost. With a variety of standard inputs the IO6N1 provides the user with the ability to interface several devices to the analog output. The IO6N1 can average two to six inputs, output the highest of two to six inputs, output the lowest of two to six inputs or output the difference of two inputs. Input ranges are jumper selectable and all modes and analog output are DIP switch selectable. Output signal is optically isolated from input signals. The IO6N1 also accepts up to 6 digital inputs (binary sequence) and outputs a proportional analog signal. The power output terminal can be used for power if the inputs are only contact closures. 24Vac (+/- 10%), 50/60 Hz 255 mA maximum 24Vdc or 15Vdc (jumper selectable) 100 mA maximum Supply Voltage: Supply Current: Power Out: Input Mode (Six Analog) Voltage Range/Impedance: Current Range/Impedance: 0...5Vdc @ 1M Ω 0...10Vdc @ 20,000 Ω 0...20Vdc @ 10,000 Ω 0...20mA @ 249 Ω (all ranges jumper selectable) Input Mode (Binary) Features •Multiple Inputs •Up to Six Analogue or up to Six Digital (Binary Sequence) Inputs •Selectable Output can: •Read Two to Six Inputs and Output the Average •Read Two to Six Inputs and Output the Lowest •Read Two to Six Inputs and Output the Highest •Read Analogue Input One and Two and Output the Difference •LED Power and Status Indicators •Input and Output is optically isolated •Selectable modes of operation using jumpers and DIP Switches •24 VAC Powered •Equipped with plug-in terminal blocks Part Code Description IO6N1 Max, Min, Average Module T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Six Digital: 15Vdc, 24Vdc or 24Vac +/-10% @ 100KΩ One Analog Output: 0...5Vdc @ 1000 Ω 0...10Vdc @ 1000 Ω 0...20Vdc @ 1000 Ω 0...20mA @ 500 Ω maximum All ranges DIP switch selectable Analog Mode Output Resolution +/-2% of full scale Binary Mode Output Resolution 64 steps of resolution Dimensions: 10.16 x 11.75 x 2.54 cm Weight: 6.6 oz (187grams) Mounting: DIN rail mounted Operating Temperature:0...70°C Storage Temperature:–20...80°C Operating Humidity: 10% to 95% non-condensing E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 45 E.C.Products Building Management Controls & Peripherals IO modules E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Electro-Pneumatic Converter IOEPC Description Technical Specification The IOEPC is an electric to pneumatic transducer which converts an analogue input signal to a proportional pneumatic output. The unit will automatically modulate its control valve to regulate the branch line pressure to the selected set point as determined by the input signal. The unit offers four selectable input ranges of 0 to 5, 0 to 10, 0 to 15 VDC and 0 to 20 mA. Output pressure ranges are jumper shunt selectable for 0 to 10, 0 to 15 and 0 to 20 psig, and adjustable in all ranges. A 0-5 VDC feedback signal indicating the resultant branch line pressure, is also provided. This signal varies linearly with branch pressure range selected. EPC’s are designed with electrical terminals on one end and pneumatic connections on the other, allowing for maximum convenience in wiring and tubing installation when panel mounted. Features •Connections oriented for convenient panel installation •Field selectable analog input ranges and pressure output ranges •Analog Feedback on branch pressure •Field adjustable offset and span •EPC bleeds at the rate of 41 scim •Closed loop control, 1% accuracy at room temperature •Plug-in Terminal Block •Not Position Sensitive •50/60 Hz Compatible •Supplied with snap track and integral-in-barb filter 46 Part Code Description IOEPC Electro Pneumatic Converter IOEPC-G Electro Pneumatic Converter with gauge T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Power Supply Voltage: 24 VDC (+10%/-5%) 24 VAC (+/-10%) 50/60 Hz at terminals Supply Current: 180 mA max. Feedback Signal Output: Factory Calibrated 0-5 VDC Input Signal Ranges: 0-5 VDC@ Infinite ohms 0-10 VDC@ Infinite ohms 0-10 VDC@ Infinite ohms 0-20 mA @ 250 ohms Air Supply: Maximum 25 psig 172.38 kPa), minimum 18 psig (124.11 kPa) Main Air Supply: 0-10 psig ( 68.95 kPa) 0-15 psig (103.43 kPa) 0-20 psig (137.9 kPa) jumper selectable output pressure ranges Accuracy: 1% full scale at room temperature 2% full scale @ 32 to 120°F Override Contact Rating: 24 VAC or 24 VDC, 1 A maximum E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Dual Phase Cut Module IOPC2 Description Technical Specification The IOPC2 converts two 0-10V dc Input Signals to drive two separate 0-20V 50Hz phase-cut outputs, at 30VA per channel for the control of small valve or damper actuators. The IOPC2 features opto-isolation, is powered from 24V ac (with a common connection to input signal) and has Rising Clamp Screw Terminals. The output from the IOPC2 can be boosted to 60VA by using two IOPCA1, 1 per channel. Features •2 x 20V 30VA Phase Cut Outputs •2 x 0-10Vdc Inputs •Opto Isolated •High Quality Rising Clamp Terminals •DIN Rail Mounting (TS35) •Optional 60VA Amplifier Module Part Code Description IOPC2 Dual Phase Cut Module 30VA IOPCA Phase Cut Amplifier Module 60VA IOPC2: Input Signal: Output Signal: Power Supply: Terminals: LED Indicators: Ambient Temp. Dimensions: 2 x 0-10Vdc 2 x 20V phase cut - 30VA per channel 24Vac (common to 0-10Vdc input) Rising Clamp for 0.5-2.5mm2 Cable ON when Power on Range: 0 to 50°C 78mm x 92.5mm x 55mm (approx.) IO modules E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH IOPCA1: Input Signal: 20V Phase Cut from AX-PCM-2-30 Output Signal: 0-20V Phase Cut - 60VA Power Supply:24Vac Terminals: Rising Clamp for 0.5-2.5mm2 Cable LED Indicators: ON when Power on Ambient Temp: Range: 0 to 50°C Dimensions: 47mm x 92.5mm x 50mm (approx.) Phase Cut Module IOPC1-120 Description Technical Specification The IOPC1-120 is designed to convert a single 0-10Vdc Input Signal to drive a 0-20V 50Hz phase-cut output, at 120VA, to drive larger valve and damper actuators. The IOPC1-120 features opto-isolation, is powered from 24Vac (with common connection to input signal) and has high quality rising clamp screw terminals. Features •120VA Phase Cut Output •0–10Vdc Input •Opto-Isolated •High Quality Rising Clamp Terminals •DIN Rail Mounting (TS35) •Integral Heatsink Part Code Description IOPC1-120 Phase Cut Module 120VA T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Input Signal: 0-10Vdc (2mA) Output Signal: 0-20V full wave rectified 50Hz phase cut VA Rating:120VA Power Supply: 24Vac (Common to 0-10Vdc input) Terminals: Rising Clamp for 0.5-2.5mm2 Cable LED Indicators: ON when Power on Ambient Temp: 0 to 50°C Dimensions: 139mm x 92.5mm x 78mm (approx.) E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 47 E.C.Products Building Management Controls & Peripherals Modbus IO modules E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Modbus & BACnet IO Modules MIX Description Technical Specification The MIX module is designed for distributed control systems using the Building JACE controller. The MIX18 provides 5UI, 5DI, 4AO and 4DO and The MIX38 provides 8UI, 12DI, 6AO and 12DO both support Modbus RTU/ASCII or BACnet MSTP communication protocol allowing communication with the building JACE. The advantage of using two open communication standards allows use in both new and existing installations as a part of the BMS. Additionally the MIX18 provides rotary switches for setting the address which simplifies and speeds up the implementation process. Effective processor with ARM Cortex M3 core allows fast communication and ensures no delays during data transfer. The module is mounted in a housing adapted for DIN rail mounting or directly on a panel. Separate easy to remove connectors allow quick wiring without removing the entire module. In addition labelled connectors help installation and replacement process. To increase the versatility of the module all relay outputs allow direct control of 230VAC at max 3 Amps which eliminates the requirement of additional relays resulting in cost savings. Power Supply:24Vac/dc Dimensions: MIX18, 88x110x62mm MIX38, 160x110x62mm Protection:IP40 Operating Temp: –10°C to 50°C Interface: RS485 half-duplex Features •A large number of all types of IO •All digital inputs can work as high speed, counters up to 100Hz •Universal inputs have 16-bit resolution which increases the accuracy of the measurement •Wide range of supported temperature sensors (NTC, PT1000 etc.) •Automatic detection of the signal type in the case of universal inputs •Digital outputs 230VAC max 3A allow direct control without additional relays •Analogue output with max 20mA load allow direct control of relays, 12Vdc or SSR with PWM support •LED’s indicate the status of inputs and outputs •Support open standards: BACnet and Modbus •RS485 communication port, half duplex •Simple and fast addressing from 1 to 99 •24VAC/DC power supply 48 Part Code Description MIX18 18 point Modbus/ BACnet IO Module MIX38 38 point Modbus/ BACnet IO Module T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Light Level Sensor AHKF/RHKF Description Technical Specification These light intensity sensors measures the light level in applications such as monitoring lighting conditions at workplaces, in outdoor areas and business facilities. It is used for daylight-dependant constant light control, as light intensity or twilight sensor and to control sunshade equipment avoiding unnecessary heating-up of rooms. Features •Outside or inside versions •Choice of output signal •Selectable ranges Power supply: 24 V AC ⁄ DC, max 10 mA @ 24 V DC Sensor:Photodiode Measuring ranges: AHKF - 0…500/20K/60K Lux (switchable via jumpers) RHKF - 0…500/1K/60K Lux Output: 4...20 mA (active) or 0 - 10 Vdc Ambient temp: –10…+ 50 °C Electrical connection:0.14 - 1.5 mm² via terminal screws Measuring error: < ± 10 % of final value Temperature drift: < ± 5 % of final value ⁄ 10 K Enclosure: Plastic colour pure white Dimensions: AHKF - 72 x 64 x 39.4 mm RHKF - 79 x 81 x 26 mm 4...20mA 0...10Vdc Description RHKF-I RHKF-U Inside Light Level Sensor 0…500/1K/60K Lux AHKF-I AHKF-U Outside Light Level Sensor 0…500/20K/60K lux Lighting control E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Wall mount sensor SPIR-FVF Description Technical Specification The SPIR-FVF series of presence detector switches are designed to provide automatic control of lighting, heating or ventilation loads. They detect movement using a PIR sensor and turn the load on. When an area is no longer occupied the load will switch off after an adjustable time out period. Features •Wall mounting on standard single gang back box •Volt free changeover contact •Suitable for lighting and heating control •Built in adjustable time delay function Part Code Description SPIR-FVF Wall mounted presence detector 230v SPIR-FVF/24 Wall mounted presence detector 24v T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Load: 10 Amp resistive load 10 Amp incandescent lighting 6 Amp fluorescent lighting 3 Amp compact fluorescent lighting 3 Amp low energy lighting 3 Amp low voltage lighting (switch primary of transformer) Fluorescent lighting (max 6 fittings recommended) For fluorescent lighting total power factor correction capacitance must not exceed 40μF 3 Amp fans and ventilation equipment Switch SON lighting loads via a contactor Supply Voltage: 220–240 Volts AC 50 Hz or 12–24Vac/dc for 24 Volt Version Time Out Period: Adjustable 10 secs to 60 mins in 2 ranges Light Level: Optional adjustment by thumbwheel light to dark Fixing Method: Surface fixing 25mm deep plastic surface mount moulded box Flush fixing 25mm steel wall box or 32mm deep cavity wall box Terminal Capacity:1.5mm2 Material: Flame retardant ABS Type: Class 2 Temperature: –10°C to 35°C Conformity:EMC-89/336/EEC LVD-73/23/EEC E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 49 E.C.Products Building Management Controls & Peripherals Lighting control E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Ceiling Mount Microwave Sensor MWS3A Description Technical Specification The MWS3A-PRM-LV (microwave) detector provides automatic control of low voltage loads including lighting and BMS systems with optional manual control. The MWS3A-PRM-LV detects movement using a highly sensitive microwave detector. This works by emitting low power microwave signals and measuring the reflections as the signals bounce off moving objects. The MWS3A-PRM-LV has a unique adjustable sensor head that allows the area of detection to be optimised for the application. Features •Flush ceiling mount or ceiling surface mount •Low voltage operation •Suitable for long range detection in corridors or warehousing 50 Load LV: Low voltage supply with relay output rating 16A resistive 10A inductive Supply Voltage: Min 11.5VDC max 36VDC, Min 10VAC max 26.5VAC Time Out Period: Adjustable 10 seconds to 99 minutes Light Level: Light to dark Terminal Capacity:2.5mm2 Material: Flame retardant ABS Type: Class 2 Temperature: –10°C to 35°C Safety: The microwave radiation emitted by these units is extremely low power. At a distance of >50mm the power density is <6% of the ANSI IEEE C95.1 –1991 recommended microwave power density. At a distance of 5mm from the unit it is <84% of recommended power density. Conformity:EMC-89/336/EEC LVD-73/23/EEC Part Code Description MWS3A-PRM-LV Microwave presence/absence detector with relay output MWS3A-DBB Surface mounting box UN-LCDHS IR remote control programming handset with LCD screen T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Infra-Red Handset UHS5 Description Technical Specification The UHS5 is a compact infrared handset used for the basic programming of IR enabled EC Products Lighting Controls Part Code Description UHS5 Infra-Red Handset Dimensions: 86mm x 4mm x 67mm Weight:0.017kg Battery: 3Vdc lithium battery CR2025 (supplied with unit) IR range:7m Temperature: 0°C to 35°C Humidity: 5 to 95% non-condensing Lighting control E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Ceiling Mount Sensor EBDSPIR–VFC Description Technical Specification The SPIR-VFC series of presence detector switches are designed to provide automatic control of lighting, heating or ventilation loads. They detect movement using a PIR sensor and turn the load on. When an area is no longer occupied the load will switch off after an adjustable time out period. Features •Flush Ceiling mounting •Volt Free changeover contact •Suitable for lighting and heating control •Built in adjustable Time delay function Part Code Description EBDSPIR-VFC Ceiling mounted presence detector 230v EBDSPIR-VFC/24 Ceiling mounted presence detector 24v EBD-BB Round Surface Mount Back Box T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Load: 6 Amp resistive load 2 Amp inductive load Supply Voltage: 230Vac 50Hz or 12-24Vac/dc (+/- 10%) for 24 Volt Version Time Out Period: Adjustable 10s to 30m Light Level: Light to dark Terminal Capacity: 2.5 mm2 Material: Flame retardant ABS Type: Class 2 Temperature: –10°C to 35°C Conformity:EMC-89/336/EEC LVD-73/23/EEC E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 51 E.C.Products Building Management Controls & Peripherals Lighting control E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Wall Mount Microwave Sensors MWS1 Description Technical Specification The MWS1A series of microwave presence detector switches are designed to provide automatic control of lighting, heating or ventilation loads. The MWS1A detects movement using a highly sensitive microwave detector. This works by emitting low power microwave signals and measuring the reflections as the signals bounce of moving objects. The MWS1A is optimised for wall mounting applications to give detection over long distances. Features MWS1A-PRM-LV: Supply Voltage:Min 11.5VDC max 36VDC, min 10VAC max 26.5VAC Power consumption: On 1.01W Off 712mW Load:Low voltage supply with relay output rating 16A resistive 10A inductive MWS1A-PRM-VFC: •Detects movement within the units detection range, allowing load control in response to changes in occupancy •Receives control and programming commands from an IR (infrared) handset •An integral adjustable photocell allows the lights to be kept off if there is sufficient ambient light •When movement is detected the load will automatically turn on. When the area is no longer occupied the load will automatically switch off after an adjustable time period. The output can be overridden on and off by activating the proximity sensor Part Code Description MWS1A-PRM-LV Microwave Motion Sensor wall mount 24V Supply Voltage: 230VAC +/- 10% Frequency:50Hz Power consumption: On 1.15W Off 790mW Load: Normally closed contact: 2 Amp maximum, Minimum load 100mA Normally open contact: 6 Amp fluorescent lighting and resistive 3 Amp compact fluorescent lighting 3 Amp low energy lighting 3 Amp low voltage lighting (switch primary of transformer) MWS1A-PRM-VFC Microwave Motion Sensor wall mount 230V Batten Mount PIR Detector EBMPIR-MB-PIR Description Technical Specification The EBMPIR-MB is a miniature PIR (passive infrared) presence detector providing automatic control of lighting loads with optional manual control using an infrared handset. It is specifically designed for mounting onto a batten style luminaire. The unit detects movement using a PIR sensor and turns the load on. When an area is no longer occupied the load will switch off after an adjustable time out period. Features •Easy Retrofit •230Volt Switched Live •Programmable Lux level and Time delay •Suitable for outdoor use 52 Part Code Description EBMPIR-MB-PIR Batten Mount PIR Detector T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Supply Voltage: 230VAC +/- 10% Max Switching Load:2 Amps fluorescent & incandescent lighting 2 Amps compact fluorescent lighting 2 Amps low energy lighting 2 Amps low voltage lighting (switch primary of transformer). Power consumption: On 799mW, Off 807mW Cable specification: 1m 1/1.13 solid core cable 105ºC Material: Flame retardant ABS/PC IP rating:IP65 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Description Metering Water Meters with Pulsed Output DxxMJ/DxxW Technical Specification For All Models This range of water meters have been designed to measure the volume of water flowing through a pipeline and are provided with a Reed Switch Pulser which can be connected to remote reading systems. Features •Dry type sealed counter •Pulsed output •Hot & Cold water versions available •Conform to ISO4064 Operating Medium Temp: Cold Water - <40°C Hot Water - <90°C Max. Error: Qmin up to Qt : ±5% Qt up to Qs : ±2% Water Pressure: 10 bar Reed Switch Voltage:24Vac/dc Reed Switch Current: 0.01A max. Model Specific Technical Specification DxMJ: Dn Size Part No Nominal Flow Max Flow mm Trans. Flow m³/hr Min. Flow L/hr Pulse Options* Body Length Length w. Couplings litres/pulse Height Width Weight mm Kg D15MJ 15 3 1.5 120 30 1-10-100 145 230 105 100 D20MJ 20 5 2.5 200 50 1-10-100 190 280 106 100 1.5 1.7 D25MJ 25 7 3.5 280 70 10-100 260 370 115 104 2.8 D32MJ 32 12 6 480 120 10-100 260 375 115 105 3.2 D40MJ 40 20 10 800 200 10-100 300 420 148 125 5.4 D50MJ 50 30 15 1050 300 10-100 300 435 173 126 8.2 DxW: Dn Size Part No Max Flow Nominal Flow mm Trans. Flow Min. Flow m³/hr Pulse Options* Length Height litres/pulse Ø Outer mm Bolt circle Bolt Ø Weight centres Kg D50W 50 30 15 3 0.45 100-1000 200 225 165 125 4xM16 16.3 D65W 65 50 25 5 0.75 100-1000 200 242 185 145 4xM16 17 D80W 80 80 40 8 1.2 100-1000 225 255 200 160 8xM16 18 D100W 100 120 60 12 1.8 100-1000 250 265 220 210 8xM16 22.8 28.3 D125W 125 200 100 20 3.0 100-1000 250 275 250 210 8xM16 D150W 150 300 150 30 4.5 1000-10,000 300 325 285 240 8xM20 46 D200W 200 500 250 50 7.5 1000-10,000 350 352 340 295 12xM20 59.6 Cold Water Hot Water Description D15MJC D15MJH 15mm Screwed Water Meter D20MJC D20MJH 20mm Screwed Water Meter D25MJC D25MJH 25mm Screwed Water Meter D32MJC D32MJH 32mm Screwed Water Meter D40MJC D40MJH 40mm Screwed Water Meter D50MJC D50MJH 50mm Screwed Water Meter D50WC D50WH 50mm Flanged Water Meter D65WC D65WH 65mm Flanged Water Meter D80WC D80WH 80mm Flanged Water Meter D100WC D100WH 100mm Flanged Water Meter D125WC D125WH 125mm Flanged Water Meter D150WC D150WH 150mm Flanged Water Meter D200WC D200WH 200mm Flanged Water Meter T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 53 E.C.Products Building Management Controls & Peripherals Metering E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Compact Heat Meters MU-DHMIL Description Technical Specification For All Models The MU-DHMIL is an Integrated multijet flow meter with two PT500 sensors and an Energy Calculator . The unit has been designed for district heating or cooling systems and is an integrated intelligent unit. It can output the data such as Data/ Pulse output to a BMS or in M-bus format. The unit stores the data six times a day in non-volatile memory, has 12 monthly values and a one year billing date which is selectable. The unit comes a Lithium Battery with a minimum 6 year life. Features •Measures Heating or Cooling •Three versions with Qp 0.6 , 1.5 or 2.5 m3/hr •Integrated meter & calculator •Pulse or M-Bus output options •Data is logged for 15 months •Very High accuracy •Matched pair of temperature sensors & cable •Supplied with Ball valve sensor pocket Power Suppl D-Cell Lithium HiCap Battery Display Type: 8 + 3 digit LCD 7mm high Display Units: MWh , optional KWh, GJ Measurement Cycle: Controlled 12.5 to 60 seconds Nominal Flow Rate: See below Meters: 15 or 20mm Multijet Sensors: 2 temperature inputs PT500 Outputs: Pulse output or M-Bus Pulse Length: 32 ms , 30Vdc@10ma Nominal Pressure: 10 bar Temperature Range: 1 to 130 deg C Ambient Temperature: 0 to 55 deg C Protection:IP54 Weight: 0.2 Kgs Model Specific Technical Specification Meters MU-DHMIL20-06 MU-DHMIL20-15 MU-DHMIL25-25 Nominal Flow in m3/hr 0.6 1.5 2.5 Maximum Flow in m3/hr 1.2 3 5 Nominal Diameter DN 15 15 20 Pressure drop at Qp 0.158 0.196 0.165 Pressure drop at Qs 0.604 0.746 0.631 Low Threshold Values - Vertical 3.5 l/hr 7.0 l/hr 10.0 l/hr Low Threshold Values - Horizontal 4.0 l/hr 7.0 l/hr 10.0 l/hr Temperature Range - Technical 5...90°C 5...90°C 5...90°C Dimensions 74.9 x 109.9 mm 74.9 x 109.9 mm 80.1 x 109.9mm Height from pipe middle 59.3mm 59.3mm 77.8mm Installation length flow sensor 110mm 110mm 130mm External Thread flow sensor G3/4” G3/4” G1” Sensors 54 Sensor colour code Blue Red Black Low Threshold Value sensor 2.5 l/hr 3.0 l/hr 5.0 l/hr Part Code Description MU-DHMIL-20-06 Compact Heat Meter Package 20mm 0.6m³/hr MU-DHMIL-20-15 Compact Heat Meter Package 20mm 1.5m³/hr MU-DHMIL-25-25 Compact Heat Meter Package 25mm 2.5m³/hr MU-DHMPTBV20 ¾” Ball Valve with Sensor Pocket MU-DHMPTBV25 1” Ball Valve with Sensor Pocket T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Heat Meter Integrator MU-DHMPI Description Technical Specification The MU-DHMPI is an exceptionally versatile Heating Calculator. The unit has been designed for district heating or cooling systems and is an integrated intelligent unit. It can output the data such as Data/Pulse output to a BMS or in M-bus format. The unit comes with a pair of matched Pt500 sensors and with as standard a Lithium Battery with a minimum 6 year life or the option of a 230Vac supply. Features •Measures Heating or Cooling •1,10,100,1000 Litre / pulse options •Pulse or M-Bus output options •230 Vac or Lithium Battery •Data is logged for 15 months Part Code Description MU-DHMPI-PO-LB Heat Meter, pulsed output, battery powered Power Supply: 230Vac, +/- 15% D-Cell Lithium HiCap Battery (minimum 6 years life) Power Consumption: <1 Watt Display Type: 7 + 3 digit LCD 7mm high Nominal Flow Rate: Qn 0.6 to 600 m3/hr Inputs: Max 2 temperature inputs PT500 1 flow meter inputs (pulse/litre) Outputs: Pulse output or M-Bus Litre per pulse options: 1, 10, 100, 1000 (specify) Pulse Length: 32ms, 30Vdc@10ma Temperature Range: 5 to 150°C Differential Range: 3K to 100K Ambient Temperature: 0 to 55°C Protection:IP54 Conformity: EN 1434, DS2340, OIML R75, PTB approved CE; LVD, EN 50 081-1 and EN 50 082-1 Metering E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH MU-DHMPI-MS-LB Heat Meter, Mbus output, battery powered MU-DHMPI-PO Heat Meter, pulsed output, 230Vac powered MU-DHMPI-MS Heat Meter, Mbus output, 230Vac powered kWh Meter MU-EM Description Technical Specification A DIN 96x96 panel mounting Electronic kWh Meter. Easy to install and convenient to use. Equally suitable for both 3 wire and 4 wire 3ph unbalanced loads (optionally for single phase or balanced 3ph systems), these Meters have been designed to measure accurately irrespective of the type of load – ideal for a motor or heater, or for a modern electronically controlled load. Features •DIN 96x96 Standard Format •Installation Aids – ‘Right First Time’ •Accuracy better than Class 1 •Isolated Pulse Output •RS485 MODBUS® Option •IP54 Protection Category •Large Clear Display Part Code Description MU-EM368-21 Panel Mount kWh Meter Pulse OP MU-EM368-22 Panel Mount kWh Meter Modbus & Pulse T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 System: 3 Phase 3 or 4 Wire Unbalanced Load Voltage: 400/230V. 3 Phase 3 or 4 Wire. Current: 5A from external CTs. Fully isolated Measurement Range: Voltage 50% to 120% Current 0.2% to 120% Frequency Range: Fundamental 45 to 65Hz Burden: Voltage <0.1VA per phase Current <0.1VA per phase Overload: Voltage x4 for 1 hour Current x40 for 0.5 second max Auxiliary Supply: 230V 50/60 Hz ±15% Load: 2VA max. Overload: x1.2 continuous Accuracy: kWh Better than Class 1 Pulse Output: 1 Pulse per unit of energy Optional Output: MODBUS® Serial Comms Temperature Operating: –10°C to +65°C Dimensions: 96 x 96 x 50 mm E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 55 E.C.Products Building Management Controls & Peripherals Metering E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Modbus Single Phase Energy Meter MU-80Modbus Description Technical Specification The MU-80Modbus Energy meter is a low cost inline meter with RS485 Modbus communication. It has a slim design allowing it to fit into a normal distribution board. With a multi-function backlit display it is easily readable even in dark locations. Features •Direct inline connection •Multifunction backlit display •Battery backup •Terminals for 10mm² cable •Modbus RS485 Communication •Din Rail Mounting Part Code Description MU-80Modbus 80A Inline Energy meter Modbus Current range:5–80Amps Voltage: 230Vac ±20% Display: Active Energy(kWh), Voltage(V), Current(A) Active Power(Kw), Reactive Power(kWAr) Apparent Power(KVA), Power Factor(cosΦ) Max Cable size:10mm² Frequency:50/60Hz Moulded Current Transformers MU-M Description Technical Specification A range of high quality current transformers the MU-M range provides accurate measurement of high primary currents, converting to a 5 Amp secondary current, proportional to the primary current. Features •High Quality •Comprehensive Measuring Class Accuracies •Wide Range of Current Ratings •Wire Sealable Terminal Covers 56 Part Code Description MU-M50 Moulded Current Transformer 50:5A MU-M100 Moulded Current Transformer 100:5A MU-M150 Moulded Current Transformer 150:5A MU-M250 Moulded Current Transformer 250:5A MU-SC100 Split Core Current Transformer 100:5A MU-SC150 Split Core Current Transformer 150:A MU-SC200 Split Core Current Transformer 200:5A MU-SC250 Split Core Current Transformer 250:5A MU-SC300 Split Core Current Transformer 300:5A MU-SC400 Split Core Current Transformer 400:5A T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 System Voltage: 720V maximum Test Voltage: 3kV for 1 minute System Frequency: 50Hz or 60Hz. Primary Ratings: From 50A to 250A (others to order) Secondary Outputs:5A Short Circuit Thermal: 3kA for 1 second Overload Withstand: 1.2 times rated current continuously Secondary Terminals: M5 screw clamps Operating Temperature: –20°C to +70°C Humidity: Up to 95% RH (non condensing E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Air Differential Pressure Sensor DF Description Technical Specification The DF pressure sensor range is used for measuring aboveatmospheric, below-atmospheric or differential pressures in air. A piezo-resistive measuring element guarantees high reliability and accuracy. These pressure sensors are used in clean room, medical and filter technology, in ventilation and air conditioning ducts, in spray booths, in large scale catering establishments for monitoring filters, for flow measuring or for triggering frequency inverters. Features •Differential pressure for air controls •Choice of output signal •User selectable output ranges Power Supply:24Vac/dc Measuring Range: See below Output Signal: 0...10Vdc or 4...20mA Media Temperature:0...+50ºC Pressure Connection: Hose Ø = 4/6 mm Type of Pressure: Differential Medium: Air, non-aggressive, non-combustible gases Accuracy: ±3% of final value (at 20ºC) Zero Point Offset: Max. +2% of final value Over Pressure: Max. 10x measuring range Long Term Stability: ±1% per year Media Contacting Parts: Brass, Ni, Nylon, PU, Si Temperature Drift Values: ±2.5% of final value/10K Current Consumption: < 20 mA Linearity: ±0.8% of final value Enclosure: 30% glass reinforced polyamide Dimensions: 72 x 64 x 39.4 mm Electrical Connections: Up to 1.5mm² via screw terminals Cable Union:M16 Humidity: <95% RH, non-precipitating Protection:IP65 Accessories: Duct connection set included Part Code Description DF-1141-0010 Air DP Sensor 0...10Vdc output - 0...100/300/500/1000 Pa DF-1142-0010 Air DP Sensor 4...20mA output - 0...100/300/500/1000 Pa DF-1141-0050 Air DP Sensor 0...10Vdc output - 0...1000/2000/3000/5000 Pa DF-1142-0050 Air DP Sensor 4...20mA output - 0...1000/2000/3000/5000 Pa T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Air pressure E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 57 E.C.Products Building Management Controls & Peripherals Air pressure E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Air Differential Pressure Sensor PA-LP Description Technical Specification The PA-LP are low cost pressure sensors with a choice of uni-directional spans. These pressure transmitters incorporate a durable piezo-resistive, silicon micro-machined sensing element to enable low pressure measurements down to 300 pascals. The transmitter is available with a choice of either 4-20mA or 2-10Vdc output and are suitable for 24 Vac/dc power supply. Features •Differential pressure for air controls •Choice of output signal •Wide choice of output ranges 58 Power Supply:24Vac/dc Supply Current: 23mA minimum Output Signal: 2 wire 4...20mA or 3 wire 2...10Vdc Media Temperature:0...+50ºC Pressure Connection: ¼” brass barbed fittings Type of Pressure:Differential Medium: Air, non-aggressive, non-combustible gases Accuracy: ±1.1% of final value (at 20ºC) Zero Point Offset: Max. +2% of final value Over Pressure: Max. 10x measuring range Temp. Drift Values: ±2. of final value/10K Enclosure:Polycarbonate Dimensions: 108 x 85 x 34 mm Electrical Connections: Up to 1.5mm² via screw terminals Cable Union:M16 Humidity: <95% RH, non-precipitating Protection:IP54 Accessories: Duct connection set included 2…10Vdc 4...20mA Description PA-LP-3-10-P-E PA-LP-3-20-P-E Air Differential Pressure Sensor 0...300 Pa PA-LP-5-10-P-E PA-LP-5-20-P-E Air Differential Pressure Sensor 0...500 Pa PA-LP-10-10-P-E PA-LP-10-20-P-E Air Differential Pressure Sensor 0...1000 Pa PA-LP-16-10-P-E PA-LP-16-20-P-E Air Differential Pressure Sensor 0...1600 Pa PA-LP-25-10-P-E PA-LP-25-20-P-E Air Differential Pressure Sensor 0...2500 Pa T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Pressure transducer PTH-3202 Description Technical Specification PTH is a series of pressure transducers which are ideal for monitoring and controlling pressure differentials in ventilation systems. PTH transducers are particularly suitable when a measurement of the actual air pressure is required for demand control ventilation. PTH transducers take up very little space and are designed for direct installation at the measuring point. PTH transducers are exceptionally compact and easy to install as there is ample room for attaching cables. Features •Temperature-compensated output signal •No risk of dust-related errors •Flexible design •Signal fluctuation damping •Protection against incorrect installation and calibration Part Code Description PTH-3202 Multi range, Selectable output PTH-3202-DF Multi range, Selectable output with Display Supply voltage: 24V AC ±15%, 50/60 Hz, 13.5-28V DC Transducer output: 0-10V, 2-10V DC, 4-20 mA, 0-20 mA DC Measuring range: –50/+50 Pa, 0/100 Pa, 0/150 Pa 0/300Pa, 0/500 Pa, 0/1000 Pa, 0/1600 Pa, 0/2500 Pa Ambient Temp. Operation:–20/+40°C (transient -30/+50°C) Accuracy at –20/+40°C: ±3% (> 350 Pa), ±10 Pa (< 350 Pa) Linearity at -20/+40°C: < ±1% of entire transducer range Maximum pressure: 20 kPa Power consumption: 2 VA (+5/+40°C), 4 VA (–20/+5°C)) Damping period: 0,4 secs. and 10 secs. Dimensions: 75 x 36 x 91 mm Cable dimension: 3 x max. 1,5 mm2 Pressure tubes: 2 x ø 6,2 Enclosure:IP54 Weight: 80 g Air pressure E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Air Differential Pressure Switch AFS-222 Description Technical Specification The AFS-222 Air Differential Pressure Switch is a general purpose proving switch designed for HVAC and Energy Management applications. It can be used to sense positive, negative, or differential air pressure. The plated housing contains a diaphragm, a calibration spring and a snap-acting SPDT switch. The sample connections located on each side of the diaphragm accept 6mm OD copper tubing via the integral compression ferrule and nut. Features •Robust Steel zinc plated housing •Brass 6mm compression connections •Wide adjustment range •HT Version supplied with Brass connection Flanges Part Code Description AFS-222 Air Differential Pressure Switch AFS-222-HT High Temp Air Differential Switch AFS-4M 4 Meter Copper Tube T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Set Point Range: 13pa to 3000pa Approximate Switching Differential:5pa to 200pa Measured Media: Air Maximum Pressure: 3000pa Operating Temperature Range: -40 to 82°C HT Version 300°C (Min 2 Meters of Copper tube must be used) Electrical Rating: 10(2) Amp. Contact Arrangement:SPDT. Electrical Connections:Screw-type terminals with cup washers. E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 59 E.C.Products Building Management Controls & Peripherals Air pressure E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Air Differential Pressure Switch 930 Description Technical Specification This 930 range of air differential pressure switches are suitable for low differential switching applications, and are ideal for providing indication of fan status or ‘filter dirty’ conditions. Features •Close switching differential •IP65 enclosure option Max. operating pressure:50 mbar Pressure Connections: 6mm ID push-on tubing Electrical rating: 1.5A(0.4) @ 250Vac Approvals: Switch according to VDE0630UG1652 Connections: Via 0.25” receptacles Cable Entry:PG11 Housing Material: Plastic moulding Protection: IP54 (IP65 mounted in 130 x 130 x 99mm enclosure c/w nipples) Ambient Range: –20ºC to +85ºC Installation Category: IEC 664 Category II Pollution Degree: IEC 664 Degree 1 Weight:250g IP54 IP65 Description 930-80 930-80-IP65 Air DP Switch 20...200 Pa with duct kit 930-83 930-83-IP65 Air DP Switch 50...500 Pa with duct kit 930-85 930-85-IP65 Air DP Switch 200...1000 Pa with duct kit Air Differential Pressure Switch Accessories Description A range of accessories for use with our range of air pressure products. 60 Part Code Description PA1-K Duct Connection Set PA1-B Right Angled Mounting Bracket PA1-K2 Plastic Pitot Tube PA-T Plastic Tee Piece PA-Y Plastic Y Piece PA-TUBE PVC Tubing per 30m Reel T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Magnehelic Gauges PAG Description Technical Specification The Magnehelic gauge is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves. A single case size is used for most models of Magnehelic gauges. They can be flush or surface mounted with standard hardware supplied. Although calibrated for vertical position, many ranges above 250Pa may be used at any angle by simply re-zeroing. However, for maximum accuracy, they must be calibrated in the same position in which they are used. These characteristics make Magnehelic gauges ideal for both stationary and portable applications. A 116mm hole is required for flush panel mounting. Complete mounting and connection fittings, plus instructions, are supplied with each instrument. Accuracy: ±2% of FS Overpressure:Relief plug opens at approximately 1.72bar, standard gauges only Connections: 1/8˝ female NPT Dimensions: 101.6 mm diameters dial Temperature: –6.67 to 60°C Media: Air and non-combustible, compatible gases Air pressure E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Features •Die cast aluminium case and bezel •Suitable for air and non-combustible gases •Overpressure protection •Shock and vibration resistant Part Code Description PAG-2000-60PA Magnehelic Gauge 0-60Pa PAG-2000-100PA Magnehelic Gauge 0-100Pa PAG-2000-125PA Magnehelic Gauge 0-125Pa PAG-2000-250PA Magnehelic Gauge 0-250Pa PAG-2000-300PA Magnehelic Gauge 0-300Pa PAG-2000-500PA Magnehelic Gauge 0-500Pa PAG-2000-750PA Magnehelic Gauge 0-750Pa PAG-2000-1000PA Magnehelic Gauge 0-1000Pa PAG-2000-0.5KPA Magnehelic Gauge 0-0.5kPa PAG-2000-1KPA Magnehelic Gauge 0-1kPa PAG-2000-1.5KPA Magnehelic Gauge 0-1.5kPa PAG-2000-2KPA Magnehelic Gauge 0-2kPa PAG-2300-60PA Magnehelic Gauge Centre Zero 30-0-30Pa PAG-2300-100PA Magnehelic Gauge Centre Zero 50-0-50Pa PAG-2300-120PA Magnehelic Gauge Centre Zero 60-0-60a PAG-2300-200PA Magnehelic Gauge Centre Zero 100-0-100Pa PAG-2300-250PA Magnehelic Gauge Centre Zero 125-0-125Pa PAG-2300-300PA Magnehelic Gauge Centre Zero 150-0-150Pa PAG-2300-500PA Magnehelic Gauge Centre Zero 250-0-250Pa PAG-2300-1000PA Magnehelic Gauge Centre Zero 500-0-500Pa Note: other ranges and scale options available T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 61 E.C.Products Building Management Controls & Peripherals Liquid pressure E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Liquid Differential Pressure Switch FD113 Description Technical Specification The FD113 is a differential pressure switch which is used for monitoring flow status across pumps, chillers etc. The unit has and adjustable setpoint with scale and ¼” BSP female pipe connections. Features •Wide Pressure Range •Suitable for mains voltages •Visible Setpoint Scale •SPDT Switch Output for high or low pressure setting Part Code Description FD113 Liquid Differential Pressure Switch PL14 Copper tube connection kit inc. 4 fittings Range: 0.3...4.5 bar Switching differential: 0.2 bar Pipe connections: 1/4” BSP female Ambient temperature:–20…+70°C Liquid temperature: 0 to 110°C Switch rating: 5(3)A @ 240Vac Protection:IP30 Dimensions: 128 x 175 x 48mm Weight:800g Liquid Differential Pressure Switch 1382 Description Technical Specification This series of pressure switches are used to monitor the difference between two pressures. For example, they can be used to monitor filter condition and signal when the filter is becoming blocked. They can also be used as flow monitoring switches if used across orifice plates etc. Features •Five standard pressure ranges •Diaphragm operated •Fully adjustable •Pressure connections 1/8” bsp parallel female brass •With plug and socket •CE marked •Complete with mounting bracket •Enclosure rating IP65 62 Part Code Description 1382P-0.25 Liquid DP Switch 20...250 mbar 1382P-1 Liquid DP Switch 0.07...1 bar 1382P-4 Liquid DP Switch 0.2...4 bar PL18 Copper tube connection kit inc. 4 fittings T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Pressure Ranges: Type 1382P-1 1382P-4 1382P-0.25 Max. Line Pressure: Electrical Ratings: Overload: Materials: Pressure Connections: Pressure Range Hysteresis 0.07 to 1 bar 0.04 bar 0.2 to 4 bar 0.07 bar 20 to 250 mbar 10 mbar Pressure range >250mbar: 34 bar Pressure range <125 mbar: 14 bar 5A @ 250V 50Hz Inductive load 4 times the range Diaphragm: Beryllium Copper All Seals: Nitrile rubber Connection:Brass Housing: Aluminium/Zinc diecast Cover: Glass Filled Nylon 1/8” BSP Female E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Liquid Differential Pressure Switch LDP Description Technical Specification The Series LDP is a differential pressure switch that makes a contact output based on the differential between two pressure sources. Wetted materials of brass and fluoroelastomer which are suitable for use with most gases and water based solutions. The switch can be used for low differential pressure indication with set point on a decrease of pressure. Features •Four Pressure ranges available •External Screw set point adjustment •Robust housing •Weatherproof Wetted Materials: Connection: Brass Diaphragm:Fluoroelastomer Temperature Limits: –1 to 60°C Pressure Limits:13.8 bar Continuous single side only pressure should not exceed 1.25x full differential range Enclosure Rating: Weatherproof UL type 4X (IP65) Repeatability: ±2% of full range Switch Type:SPDT Electrical Rating: 5 A @ 125/250 Vac, 5 A res. @ 30 Vdc Electrical Connection:Removable terminal block Process Connection: 1/4˝ NPT female 2 NPT to 6mm compression fittings supplied Set Point Adjustment:External screw Liquid pressure E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Part Code Description LDP-0.7 Liquid Differential Pressure Switch 0.17 to 0.69 bar LDP-1.7 Liquid Differential Pressure Switch 0.69 to 1.72 bar LDP-3.5 Liquid Differential Pressure Switch 1.72 to 3.45 bar LDP-5 Liquid Differential Pressure Switch 3.46 to 5.17 bar Liquid Differential Pressure Sensor 482 Description Technical Specification The 482 range of Liquid DP sensors use a piezo-resistive sensor and incorporate zero and span adjustment. They are ideal for use in areas requiring exact pressure measurement, low hysteresis and long term stability in all applications where air, oil or water is to be monitored. Features •Economical Differential Pressure Sensors •0...10Vdc or 4...20mA output •Choice of measuring range •Supplied with 1 metre flying lead •Complete with mounting bracket Output Signal: 0...10Vdc 3 wire or 4...20mA 2 wire Power Supply: 0...10Vdc - 24Vac/dc 4...20mA - 24Vdc Pressure Ranges: See below Over Pressure: 1.5 x FS Accuracy: 0.25% FS Repeatability: 0.2% FS/Year typical Pressure Connection: 1/8” BSP female Temperature:–20…+80°C Humidity: 0...80% RH 0...10Vdc 4...20mA Description 482-0.4V 482-0.4 Liquid Differential Pressure Sensor 0...0.4 bar 482-1V 482-1 Liquid Differential Pressure Sensor 0...1 bar 482-2V 482-2 Liquid Differential Pressure Sensor 0...2 bar 482-4V 482-4 Liquid Differential Pressure Sensor 0...4 bar 482-7V 482-7 Liquid Differential Pressure Sensor 0...7 bar 482-10V 482-10 Liquid Differential Pressure Sensor 0...10 bar Copper tube connection kit inc. 4 fittings PL18 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 63 E.C.Products Building Management Controls & Peripherals Liquid pressure E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Liquid Pressure Switch PS1 Description Technical Specification The PS1 is a cost effective pressure switch suitable for monitoring pumps, chillers, valves etc. The unit has an adjustable setpoint with adjustable differential and has a gauge to show the liquid pressure. Features •Wide Pressure Range •Suitable for mains voltages •Visible Setpoint Scale •SPDT Switch Output Part Code Description PS1 Liquid Pressure Switch –0.5...7 bar Range: –0.5...7 bar Differential: 0.5...5 bar Pressure Connection: ¼” BSP male Contact Rating: 24(10) @ 230Vac Protection:IP44 Ambient Temperature:–50…+70°C Liquid Temperature:–50…+70°C Dimensions: 86 x 75 x 44mm Liquid Static Pressure Sensor PT603 Description Technical Specification The PT603 range of Liquid Pressure sensors use a piezo-resistive sensor and incorporate IP65 connector for wiring with a ¼” BSP threaded connection. They are ideal for use in areas requiring exact pressure measurement, low hysteresis and long term stability in all applications where air, oil or water is to be monitored. Features •Economical Pressure Sensors •0...10Vdc or 4...20mA output •Choice of measuring range •1/4” BSP threaded connection 64 Output Signal: 0...10Vdc 3 wire or 4...20mA 2 wire Power Supply: 0...10Vdc - 24Vac/dc 4...20mA - 24Vdc Load Resistance: 0...10Vdc - >50KΩ 4...20mA - <800Ω Pressure Ranges: See below Accuracy: 0.2% FS Repeatability: 0.1% FS/Year typical Pressure Connection: ¼” BSP male Wiring: IP65 Hirschmann Connector Temperature:–10…+80°C Humidity: 0...80% RH 0...10Vdc 4...20mA Description PT603-0.1V PT603-0.1 Liquid Static Pressure Sensor 0-100 mbar PT603-0.25V PT603-0.25 Liquid Static Pressure Sensor 0-250 mbar PT603-0.6V PT603-0.6 Liquid Static Pressure Sensor 0-600 mbar PT603-1V PT603-1 Liquid Static Pressure Sensor 0-1 bar PT603-4V PT603-4 Liquid Static Pressure Sensor 0-4 bar PT603-6V PT603-6 Liquid Static Pressure Sensor 0-6 bar PT603-10V PT603-10 Liquid Static Pressure Sensor 0-10 bar PT603-25V PT603-25 Liquid Static Pressure Sensor 0-25 bar T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Single Phase DIN Rail Thyristor Controllers TCD1 Description Technical Specification The DIN Rail mounting Power Controllers TCD1 is suitable for providing control of electric heating loads from an analogue signal. Applications include electric heating coils, heating cables and electric furnaces. The units utilise solid-state switching with “zero crossing technology” to provide accurate switching control. All items are provided with an alarm output for over temperature protection and LED Indication of Output ON. The TCD1 are designed to mount on DIN rail. Features •Selectable Control Input •2Kw, 4kW and 7kW Models •Over Temperature Protection •24Vac/dc or self-powered options •LED Indication •DIN Rail Mounting Part Code Description TCD1-2 Single Phase DIN Rail Thyristor Controller 2Kw TCD1-4 Single Phase DIN Rail Thyristor Controller 4Kw TCD1-7 Single Phase DIN Rail Thyristor Controller 7Kw TCD1-x-SP Self-powered Option Factory fitted Input: Selectable 0...10V, 0...5V, 2...10V, 4...20mA Power Supply: 24Vac/dc +/-10% (self-powered option) Alarm Output: 24V alarm output drops to 0V on alarm for connecting to external relay Max Heater Duty: 2Kw, 4Kw or 7Kw dependent on model Rated Load: Load@220V Dissipated Heat 2Kw9A 9W 4Kw18A 23W 7Kw30A 35W Rated Supply: 220...255Vac, 50/60Hz LED Indication: ON when output is on. Terminals: Rising cage terminals Ambient Temp. Range: Maximum 45°C without de-rating Dimensions: 2Kw - 75 x 94 x 80 mm 4/7Kw - 170 x 94 x 102 mm Country of Origin: United Kingdom Thyristors E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Three Phase DIN Rail Thyristor Controllers TCD3 Description Technical Specification The DIN Rail mounting Power Controllers TCD3 are suitable for providing control of electric he ating loads from an analogue signal. Applications include electric heating coils, heating cables and electric furnaces. The units utilise solid-state switching with “zero crossing technology” to provide accurate switching control. All items are provided with an alarm output for over temperature protection and LED indication of Output ON. The TCD3 are designed to mount on a DIN rail. Features •Selectable Control Input •12kW and 18kW Models •Over Temperature Protection •24Vac/dc or self-powered options •LED Indication •DIN Rail Mounting Part Code Description TCD3-12 Three Phase DIN Rail Thyristor Controller 12Kw TCD3-18 Three Phase DIN Rail Thyristor Controller 18Kw TCD3-x-SP Self-powered Option Factory fitted T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Input: Selectable 0...10V, 0...5V, 2...10V, 4...20mA Power Supply: 24Vac/dc +/-10% (self-powered option) Alarm Output: 24V alarm output drops to 0V on alarm for connecting to external relay Rated Load: Load/Ph Dissipated Heat 12Kw16A 33W 18Kw25A 50W Max Heater Duty: 12Kw or 18Kw dependent on model Rated Supply: 380...440Vac, 50/60Hz LED Indication: ON when output is on. Terminals: Rising cage terminals Ambient Temp. Range:Maximum 45°C without de-rating Dimensions: 170 x 110 x 102 mm Country of Origin: United Kingdom E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 65 E.C.Products Building Management Controls & Peripherals Thyristors E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Three Phase Panel Mounted Thyristor Controllers TCP3 Description Technical Specification The panel mounting Power Controllers TCP3 are suitable for providing control of electric heating loads from an analogue signal. Applications include electric heating coils, heating cables and electric furnaces. The units utilise solid-state switching with “zero crossing technology” to provide accurate switching control. All items are provided with an alarm output for over temperature protection and LED Indication of Output ON. The TCP3 are designed to mount on the control panel backplate. Features Input: Selectable 0...10V, 0...5V, 2...10V, 4...20mA Power Supply: 24Vac/dc +/-10% (self-powered option) Alarm Output: 24V alarm output drops to 0V on alarm for connecting to external relay Max Heater Duty: 27Kw, 36Kw or 57Kw dependent on model Rated Load: Load/Ph Dissipated Heat 27Kw37A 36Kw50A 57Kw80A 84W 100W 160W Rated Supply: 380...440Vac, 50/60Hz LED Indication: ON when output is on. Terminals: Control - Rising cage terminals Power - DIN rail terminals Ambient Temp. Range:Maximum 45°C without de-rating Dimensions: 27/36Kw - 257 x 102 x 142 mm 57Kw - 257 x 200 x 158 mm Country of Origin: United Kingdom •Selectable Control Input •27Kw, 36Kw and 57Kw Models •Over Temperature Protection •24Vac/dc or self-powered options •LED Indication •Panel Mounted Part Code Description TCP3-27 Three Phase Panel Mount Thyristor Controller 27Kw TCP3-36 Three Phase Panel Mount Thyristor Controller 36Kw TCP3-57 Three Phase Panel Mount Thyristor Controller 57Kw TCP3-x-SP Self-powered Option Factory fitted Slim Line Switch Mode Power Supplies DR15 Description Technical Specification The DR15 power supplies are a slim 17.5mm wide Din rail mounting 15W dc power supply, ideal for applications where space is critical and only low DC power is needed, with visual indication of input voltage and supply on. Fitted with and internal replaceable input fuse and auto recovery short circuit protection. Output current:@ –20 to +40°C, 230 Vac input 12 Volt 1.25A / 24V 0.63A Rated power: 12 Watts Output power: @–20...+40°C, 230 Vac input 15 Watts Input voltage: 110 to 240 Vac Dimensions: 17.5mm wide, 60mm deep Features •High efficiency (up to 91%) • Short circuit protection: hiccup (auto-recovery) Mode • Dual and series connection permissible • Input protection: replaceable internal fuse 66 Part Code Description DR15-12 12Vdc 15W Switch mode power supply DR15-24 24Vdc 15W Switch mode power supply T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Universal Input Power Supply DRx0-xx Description Technical Specification These Switch mode power supplies are a universal AC voltage input with a regulated dc output capable of supplying 2.5Amps. The Units incorporate LED power on indication and have dual output terminals. This Unit has a small footprint so is ideal when space on the DIN is restricted. Features •DIN rail mounting •Universal AC input •LED indicator for power on •3 year warranty Part Code Description DR30-12 Universal Input 12Vdc Power Supply DR60-24 Universal Input 24Vdc Power Supply AC Input Voltage: 85-264Vac, 47-63Hz AC inrush Current: Cold start 27A at 115Vac, 36A at 230Vac Output Voltage: DR30-12: 12Vdc DR60-24: 24Vdc Adjustment Range: ±10% rated voltage Output Current:0...2.5A Output Power: DR30-12: 30W DR60-24: 60W LED Indication: Power On Accuracy:±1% Efficiency:84% Overvolt Protection: 115%...135% rated output voltage Overload Protection: 120%...140% rated output voltage Terminals: Rising clamp 0.5-2.5mm² cable Ambient: –20°C to +50°C @ 100%, 60°C @ 80% load Dimensions: 93mm(H) x 78mm(W) x 55mm approx Power supplies E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Din Rail Mount AC Power Supplies PSD Description Technical Specification The PSD Din Rail Mounted Power Supplies are designed for applications where a low current AC Supply is required such as valves and Damper actuators. Features •Din Rail mounting •Compact •Fused Primary and Secondary •240Vac Primary, 24Vac Secondary •1.5VA, 6VA and 15VA Versions Part Code Description PSD-1.5 Din Rail Transformer 24Vac 1.5VA PSD-6 Din Rail Transformer 24Vac 6VA PSD-15 Din Rail Transformer 24Vac 15VA T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Output:24Vac Supply Voltage:230Vac Current ratings: 1.5VA, 6VA and 15VA Termination: Rising Clamp for 0.5 to 2.5mm² Cable. Fuse rating: 1.5VA100mA 6VA250mA 15VA630mA Dimensions:1.5VA: 47 x 55 x 93 mm 6VA: 58 x 60 x 93 mm 15VA: 80 x 69 x 93 mm E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 67 E.C.Products Building Management Controls & Peripherals Power supplies E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 24Vac to 24Vdc Power Supplies PS-24 Description Technical Specification The PS-24 is a DIN rail mounted power supply providing a regulated 24Vdc output from a 24Vac supply and is suitable for all DC power requirements such as sensors. Features •Regulated 24Vdc Output at 1A •Fused output protection •LED Power indication •DIN rail mounting Part Code Input Supply: 24Vac ±15% Output Supply: 24Vdc ±10% @ 1A Output Fuse:1A LED Indication: Power ON Terminals: Rising clamp 0.5-2.5mm² cable Ambient: 0°C to +50°C, 0-80% RH non-condensing Dimensions: 76mm(H) x 57mm(W) x 62mm approx Description PS-24AC-DC-E 24Vac to 24Vdc Power Supply - Earthed Output PS-24AC-DC-F 24Vac to 24Vdc Power Supply - Floating Output 230Vac Transformers PS Description Technical Specification The PS 230Vac to 24Vac Transformers are available in a choice of power ratings and are suitable for a wide of range of power supply applications requiring a 24Vac supply. Features Input Voltage: Output Voltage: 24Vac ±10% Terminals: Rising clamp 0.5 – 2.5mm² cable Ambient: –10°C to +50°C, 0-95% RH non-condensing •M4 Stud Earth Connector •Ratings up to 250V 68 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 220/240Vac ±5% Outline Dimensions (mm) Part Code Rated Power (VA) W L H PS-25 25 60 78 72 PS-50 50 77 75 70 PS-100 100 86 82 78 PS-150 150 97 82 85 PS-250 250 115 93 98 Part Code Description PS-25 230Vac transformer 25VA PS-50 230Vac transformer 50VA PS-100 230Vac transformer 100VA PS-150 230Vac transformer 150VA PS-250 230Vac transformer 250VA E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Humidity Sensors RHTRx / RHTDx / RHTOx Description Technical Specification This type of relative humidity and temperature sensors utilize state-of-the-art single chip multi-sensor module comprising a calibrated digital output to enable stability and immunity to interference. Application of CMOS processes with patented micro-machining ensures highest reliability and excellent longterm stability. The device includes a capacitive polymer sensing element for RH and a bandgap temperature sensor. Both are seamlessly coupled to a 14 bit analog to digital converter, and a serial interface circuit on the same chip. Due to its integrated sensing and D/A conversion, it enables high signal quality, fast response time and immunity to external disturbance. Features •High Noise immunity for stability by digitized signals •Output is selectable 0-10V or 4-20mA •No loss of accuracy up to 100% RH •4 selectable temperature ranges •24V AC/DC supply •Direct Thermistor Option Humidity: RH sensor: Capacitive polymer Accuracy: +/- 3% or +/-2% @ 25°C Response time: < 8 sec Long term stability:< 2% RH per year Hysteresis: +/- 1% RH Output:0-100%RH Humidity E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Temperature: Bandgap temperature sensor Accuracy: ±0.5 deg C at 25°C Response time: < 8 sec Housing material:ABS Ambient range: –20°C to +50°C Power Supply: 24AC/DC supply for 0-10V 24Vdc supply for 3 wire 4-20mA Connection: 0.5-1.5 mm cable. Dimensions: RHTR: RHTD: RHTO: Part Code Description RHTR2 2% Space Humidity & Temperature Sensor RHTR3 3% Space Humidity & Temperature Sensor RHTR2-T 2% Space Humidity Sensor with direct thermistor RHTR3-T 3% Space Humidity Sensor with direct thermistor RHTD2 2% Duct Humidity & Temperature Sensor RHTD3 3% Duct Humidity & Temperature Sensor RHTD2-T 2% Duct Humidity Sensor with direct thermistor RHTD3-T 3% Duct Humidity Sensor with direct thermistor RHTO2 2% Outside Humidity & Temperature Sensor RHTO3 3% Outside Humidity & Temperature Sensor RHTO2-T 2% Outside Humidity Sensor with direct thermistor RHTO3-T 3% Outside Humidity Sensor with direct thermistor RH-SS1 Radiation Shield for RHTD 85 x 85 x 28 mm 96mm dia. Housing x 56mm high Probe - 230mm long 96mm dia. Housing x 56mm high Probe - 85mm long Please specify thermistor type when ordering direct thermistor outputs T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 69 E.C.Products Building Management Controls & Peripherals Humidity E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Humidity & Temperature Sensors RFF/RFTF/KFF/KFTF Description Technical Specification The RFF/KFF range of humidity sensors is used in refrigeration and air conditioning. They convert the humidity and temperature measurements into analogue signals of 0...10Vdc or 4...20mA. A capacitive RH sensor and NTC thermistor provide accurate measurements and long term stability. Power Supply: Sensors: Measuring Range: Operating Range: Accuracy: Outputs: Connection: Enclosure: Features •Humidity only or Humidity & Temperature •Temperature Outputs •Optional Direct Thermistor for temperature measurement •Choice of outputs •Space or Duct Mount Versions Part Code Description RFF-I 3% Space Humidity Sensor 4...20mA output RFF-U 3% Space Humidity Sensor 0...10Vdc output RFF-x-T Direct Thermistor Option for RFF-I/RFF-U RFTF-I 3% Space Humidity & Temperature Sensor 4...20mA output RFTF-U 3% Space Humidity & Temperature Sensor 0...10Vdc output KFF-I 3% Duct Humidity Sensor 4...20mA output KFF-U 3% Duct Humidity Sensor 0...10Vdc output KFTF-I 3% Duct Humidity & Temperature Sensor 4...20mA output KFTF-U 3% Duct Humidity & Temperature Sensor 0...10Vdc output 24Vac/dc for 0..10Vdc output 15...36Vdc for 4...20mA output max. load 500Ω Capacitive Humidity sensor, NTC temp. Humidity - 0...100% RH Temperature - 0...50°C Humidity - 10...90% RH Temperature - 0...50°C Humidity - ±3% RH 40...60% RH otherwise ±5% Temperature - ±0.8K at 20°C 0...10Vdc or 4...20mA 0.5-1.5 mm cable. RFF - White ABS 79 x 81 x 26 mm KFF - Polyamide 72 x 64 x 39.4 mm Duct Humidistats DBKH Description Technical Specification Relative duct humidity control in air conditioning systems with set point adjustment by knob and control of 1 stage humidifiers and dehumidifiers. Well-suited in domestic, commercial and industrial areas for a large variety of applications in the air conditioning field. Features •Exposed or concealed Setpoint adjustment •Suitable for swimming pool applications 70 Part Code Description DBKH-10 Duct Humidistat DBKH-10U Duct Humidistat, concealed setpoint T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Sensitive elem.: Several synthetic fabric bands. Contacts: SPDT contacts Switch capacity: Humidify: 2 A, 250 Vac Dehumidify: 5 A, 230 Vac Differentials:4% Working temp.: 0...+60 °C Storage: –20...+70 °C Temp. coeff.: –0.2% r.h./K at 20 °C Max air velocity: 15 m/s Housing:ABS Weight: 0.12 kg Size: 115 x 70 x 35 mm Protection:IP20 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Space Humidistats DBZH Description Technical Specification Relative space humidity control in air conditioning systems with set point adjustment by knob and control of 1 stage humidifiers and dehumidifiers. Well-suited in domestic, commercial and industrial areas for a large variety of applications in the air conditioning field. Features •Exposed or concealed Setpoint adjustment •Suitable for swimming pool applications Part Code Description DBZH-101 Space Humidistat Sensitive elem.: Several synthetic fabric bands. Contacts: SPDT contacts Switch capacity: Humidify: 2 A, 250 Vac Dehumidify: 5 A, 230 Vac Differentials:4% Working temp.: 0...+60 °C Storage: –20...+70 °C Temp. coeff.: –0.2% r.h./K at 20 °C Max air velocity: 15 m/s Housing:ABS Weight: 0.12 kg Size: 115 x 70 x 35 mm Protection:IP20 Room temperature sensors E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Space Temperature Sensors TE-Rx Description Part Code Description The TE-R range of space temperature sensors are designed to interface with a wide variety of HVAC control equipment. Units are available with a high quality thermistor element or platinum element. TE-RT 10K3A1, Trend TE-RA 10K4A1, Andover, Delta TE-RH 20K6A1, Honeywell The housing is designed for direct surface mounting and with fixing holes for standard recessed patress and conduit boxes. TE-R100 PT100A TE-R1K PT1000A, Cylon TE-RLAN Ni1000 TK5000, Siemens TE-RSAT Satchwell TE-RTAC 1.8K3A1, TAC TE-R3K 3K3A1, Alerton TE-RD 30K6A1, Drayton TE-RP 50K6A1, Priva TS-GD Sensor guard The housing is designed to maximise air flow through it thus providing fast response times and returning values indicative of the space in which it is installed. Features •Flame retardant ABS housing •Wide choice of sensor options Technical Specification Sensor Type: Thermistor or RTD element Accuracy: Thermistor - ±0.2°C, 0...70°C RTD - Class A ±0.15°C @ 0°C, ±0.35°C @ 100°C Housing: Flame retardant ABS Colour:White Protection:IP30 Terminals: Rising clamp 0.5-2.5mm² cable Ambient: –20°C to +60°C, 0-95% RH non-condensing Dimensions: 85mm(H) x 85mm(W) x 30mm approx T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Room temperature sensors DBZH-101U Space Humidistat, concealed setpoint For Set point, add: /T For Button, add: /B For Switch, add: /S For Red LED, add: /R For Green LED, add: /G E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 71 E.C.Products Building Management Controls & Peripherals Ceiling sensor E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Ceiling Mounted Temperature Sensor TE-DTFx Description Small built-in temperature sensor for in-wall installation. It is preferably installed in walls and ceilings, fitting in well with the overall view of architecture. Features •Wide choice of sensor options Technical Specification Description TE-DTF/T 10K3A1, Trend TE-DTF/A 10K4A1, Andover, Delta TE-DTF/H 20K6A1, Honeywell TE-DTF/100 PT100A TE-DTF/1K PT1000A, Cylon TE-DTF/LAN Ni1000 TK5000, Siemens TE-DTF/TAC 1.8K3A1, TAC For other lengths add length to end of Part number when ordering. Lengths available from Stock 50, 65, 75, 100, 200, 250, 300, 350, 400, 500, 600, 700, 800, 1000mm Measuring range: –20...+ 90 °C Sensor Type: Thermistor or RTD element Accuracy: Thermistor - ±0.2°C, 0...70°C, RTD - Class A Connecting cable: ca. 135 mm, 2 x 0.25 mm² Colour: Signal white Connecting head:Aluminium Process connection: Inside suspended ceiling, cutout Ø = 26 mm Humidity: < 95 % r. H. Protection type: IP 30 Outside temperature sensors Part Code Outside Air Temperature Sensors TE-Ox Description The TE-O range of outside air temperature sensors are designed to interface with a wide variety of HVAC control equipment. Units are available with a high quality thermistor element or platinum element. The housing has a quick release lid for ease of installation and the sensor sealed into a brass lug mounted into the side of the housing. Features •IP65 Flame retardant ABS housing •Brass sensor lug •Wide choice of sensor options •Available with radiation shield Part Code Standard With Radiation Shield Description TE-OT TE-OT/RS 10K3A1, Trend TE-OA TE-OA/RS 10K4A1, Andover, Delta TE-OH TE-OH/RS 20K6A1, Honeywell TE-O100 TE-O100/RS PT100A TE-O1K TE-O1K/RS PT1000A, Cylon TE-OLAN TE-OLAN/RS Ni1000 TK5000, Siemens TE-OSAT TE-OSAT/RS Satchwell TE-OTAC TE-OTAC/RS 1.8K3A1, TAC TE-O3K TE-O3K/RS 3K3A1, Alerton TE-OD TE-OD/RS 30K6A1, Drayton TE-OP TE-OP/RS 50K6A1, Priva Technical Specification Sensor Type: Thermistor or RTD element Accuracy: Thermistor - ±0.2°C, 0...70°C RTD - Class A ±0.15°C @ 0°C, ±0.35°C @ 100°C Housing: Flame retardant ABS Probe: Brass Lug Protection:IP65 Terminals: Rising clamp 0.5-2.5mm² cable Ambient: –20°C to +50°C, 0-95% RH non-condensing 72 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Description The Black Bulb temperature sensor determines the effective portion of active radiation or also the effective radiant heat at the measured location. Due to the measuring method applied by the dark radiation temperature sensor in combination with its positioning in the room, excellent measuring results are achieved. Features •Flame retardant ABS housing Space IP65 Description TE-RB/T TE-OB/T 10K3A1, Trend TE-RB/A TE-OB/A 10K4A1, Andover, Delta TE-RB/H TE-OB/H 20K6A1, Honeywell TE-RB/100 TE-OB/100 PT100A TE-RB/1K TE-OB/1K PT1000A, Cylon TE-RB/LAN TE-OB/LAN Ni1000 TK5000, Siemens TE-RB/TAC TE-OB/TAC 1.8K3A1, TAC Technical Specification Sensor Type: Thermistor or RTD element Housing: Flame retardant ABS - white Protection:IP30/IP65 Terminals: Rising clamp 0.5-2.5mm² cable Ambient: –20°C to +60°C, 0-95% RH Button Temperature Sensors TE-Bx Description The TE-B range of button temperature sensors are designed to interface with a wide variety of HVAC control equipment. Units are available with a high quality thermistor element or platinum element. Features •Button type housing for discrete temperature measurement •Plastic, stainless steel or brass versions •Wide choice of sensor options Technical Specification Sensor Type: Thermistor or RTD element Accuracy: Thermistor - ±0.2°C, 0...70°C RTD - Class A ±0.15°C @ 0°C, ±0.35°C @ 100°C Housing:White Plastic, Satin Brass, Polished Brass or Stainless Steel Protection:IP30 Termination: 300mm of PVC flying lead Ambient: 0°C to +50°C, 0-95% RH non-condensing T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Part Code Description TE-BT 10K3A1, Trend TE-BA 10K4A1, Andover, Delta TE-BH 20K6A1, Honeywell TE- B100 PT100A TE- B1K PT1000A, Cylon TE-BLAN Ni1000 TK5000, Siemens TE-BTAC 1.8K3A1, TAC TE-B3K 3K3A1, Alerton TE-BD 30K6A1, Drayton TE-BP 50K6A1, Priva For Plastic, add: /P For Satin Brass, add: /B Button temperature sensors Black Bulb Temperature Sensors TE-RB/OBx Radiant temperature sensors E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH For Polished Brass, add: /PB For Stainless Steel, add: /SS For Matching Plate add:/BP for brass /PBP for Polished brass /SP for Stainless /PP for Plastic E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 73 E.C.Products Building Management Controls & Peripherals Thimble temperature sensors Anti-ligature temperature sensors E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Anti-Ligature Sensor TE-AL Description The TE-AL Anti-Ligature sensors are designed for use where Space temperature needs to be monitored and a discrete finish is required, they are available in 3 standard finishes but can also be a customer specific finish. Features •Extremely low profile •3 Standard finishes available from stock •Wide choice of sensor types Technical Specification Sensor Type: Accuracy: 100°C Plate finishes: Protection: Termination: Ambient: Thermistor or RTD element Thermistor - ±0.2°C, 0...70°C RTD - Class A ±0.15°C @ 0°C, ±0.35°C @ White plastic, brass or stainless steel IP30 250mm flying lead 0°C to +50°C, 0-95% RH non-condensing Description TE-AL-T 10K3A1, Trend TE-AL-A 10K4A1, Andover, Delta TE-AL-H 20K6A1, Honeywell TE- AL-100 PT100A TE-AL-1K PT1000A, Cylon TE-AL-LAN Ni1000 TK5000, Siemens TE-AL-TAC 1.8K3A1, TAC TE-AL-3K 3K3A1, Alerton TE-AL-D 30K6A1, Drayton TE-AL-P 50K6A1, Priva For Plastic, add: /P For Satin Brass, add: /B For Polished Brass, add: /PB For Stainless Steel, add: /SS Thimble Temperature Sensors TE-Tx Description Part Code Description The TE-T range of thimble temperature sensors are designed to Interface with a wide variety of HVAC control equipment. Units are available with a high quality thermistor element or platinum element. TE-TT 10K3A1, Trend TE-TA 10K4A1, Andover, Delta TE-TH 20K6A1, Honeywell The sensor is housed in a white plastic thimble type enclosure with optional aluminium, brass or stainless steel versions also available. TE-T100 PT100A TE-T1K PT1000A, Cylon TE-TLAN Ni1000 TK5000, Siemens TE-TSAT Satchwell TE-TTAC 1.8K3A1, TAC TE-T3K 3K3A1, Alerton TE-TD 30K6A1, Drayton TE-TP 50K6A1, Priva TE-Tx-B Brass Thimble TE-Tx-AL Aluminium Thimble TE-Tx-SS St. Stl. Thimble TE-Tx-PB Polished Brass Features •Thimble type housing for discrete temperature measurement •Plastic, brass, stainless steel or aluminium versions •Wide choice of sensor options Technical Specification Sensor Type: Thermistor or RTD element Accuracy: Thermistor - ±0.2°C, 0...70°C RTD - Class A ±0.15°C @ 0°C, ±0.35°C @ 100°C Housing: White plastic, brass, aluminium or stainless steel Protection:IP30 Termination: 2 metres of PVC flying lead Ambient: 0°C to +50°C, 0-95% RH non-condensing 74 Part Code T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Description Part Code Description The TE-AV range of duct averaging temperature sensors are designed to interface with a wide variety of HVAC control equipment. Units are available with a high quality thermistor element or platinum element. TE-AVT 10K3A1, Trend TE-AVA 10K4A1, Andover, Delta TE-AVH 20K6A1, Honeywell The housing has a quick release lid for ease of installation and gasket for sealing to the duct. The probe is flexible copper and is available in standard 2 metre length. TE-AV100 PT100A TE-AV1K PT1000A, Cylon TE-AVSAT Satchwell TE-AVTAC 1.8K3A1, TAC TE-AV3K 3K3A1, Alerton TE-AVP 50K6A1, Priva Features •IP65 Flame retardant ABS housing •Stainless steel probe •Wide choice of sensor options Technical Specification Sensor Type: Thermistor or RTD element - see order codes Accuracy: Thermistor - ±0.2°C, 0...70°C RTD - Class A ±0.15°C @ 0°C, ±0.35°C @ 100°C Housing: Flame retardant ABS Probe: 6mm diameter flexible copper 2000mm Protection:IP65 Terminals: Rising clamp 0.5-2.5mm² cable Ambient: –20°C to +85°C, 0-95% RH non-condensing Low Profile Temperature Sensor TE-LP Description The TE-LP Low profile temperature sensor is for applications where the conventional Thimble sensor is too obtrusive such as high end housing and offices, it offers good response characteristics due to the vertical groves on the front. It is available in 5 finishes as standard but other specified finishes can be made to order. Features •Low profile design •8mm Diameter fixing. •5 finishes available as standard. •Wide range of sensor types available. Description TE-LPT 10K3A1, Trend TE-LPA 10K4A1, Andover, Delta TE-LPH 20K6A1, Honeywell TE- LP100 PT100A TE- LP1K PT1000A, Cylon TE-LPLAN Ni1000 TK5000, Siemens TE-LPTAC 1.8K3A1, TAC TE-LP3K 3K3A1, Alerton TE-LPD 30K6A1, Drayton TE-LPP 50K6A1, Priva For Plastic, add /P Technical Specification Sensor Type:Thermistor or RTD element Accuracy: Thermistor: ±0.2°C, 0...70°C RTD: Class A ±0.15°C @ 0°C, ±0.35°C @ 100°C Housing: Brass, Stainless Steel or Plastic Termination: 250mm Lead Ambient: 0°C to +50°C, 0-95% RH non-condensing Dimensions: M8 Threaded fixing, 19mm diameter face x 4.5mm T: +44 (0)20 8569 4100 Part Code F: +44 (0)20 8569 4111 For Satin Brass, add /B For Polished Brass, add /PB Low profile temperature sensors Duct Averaging Temperature Sensors TE-AVx Averaging temperature sensors E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH For Stainless Steel, add /SS For Matching Plate, add /BP for brass /PBP for Polished brass /SP for Stainless /PP for Plastic E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 75 E.C.Products Building Management Controls & Peripherals Telescopic temperature sensors E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Telescopic Duct/Immersion Sensor TE-ET380 Description Part Code Description The TE-ET380 is a Telescopic sensor suitable for mounting in Ducts or in an Immersion pocket. It can be used for applications where a non-standard length is required extending from 150 to 380mm. TE-ET380/T 10K3A1, Trend TE-ET380/A 10K4A1, Andover, Delta TE-ET380/H 20K6A1, Honeywell The housing has a quick release lid for ease of installation and a gasket is supplied for sealing to a duct. The probe is chrome plated brass with a Stainless steel tip for good corrosion resistance. The sensor will fit our standard Brass or Stainless Steel pockets. Special length pockets can be ordered. TE-ET380/100 PT100A TE-ET380/1K PT1000A, Cylon TE-ET380/LAN Ni1000 TK5000, Siemens TE-ET380/SAT Satchwell TE-ET380/TAC 1.8K3A1, TAC TE-ET380/3K 3K3A1, Alerton TE-ET380/D 30K6A1, Drayton TE-ET380/P 50K6A1, Priva Features •IP65 Flame retardant ABS housing •Telescopic probe •Chrome plated brass probe stainless Steel tip •Wide choice of sensor options Technical Specification Immersible temperature sensors Sensor Type: Thermistor or RTD element Accuracy: Thermistor - ±0.2°C, 0...70°C RTD - Class A ±0.15°C @ 0°C, ±0.35°C @ 100°C Housing: 6mm OD Chrome plated probe, Stainless steel tip Protection:IP65 Terminals: Rising clamp 0.5-2.5mm² cable Ambient: -20°C to +85°C, 0-95% RH non-condensing. 76 Immersible Sensor TE-FL*/IM/5 Description The TE-FL range of Immersible temperature sensors are designed to interface with a wide variety of HVAC control equipment. These sensors can be completely submersed to a depth of 4 meters. Features •5 meter standard length •PVC outer sleeve •150mm Stainless Steel probe Technical Specification Sensor Type: Thermistor or RTD element Accuracy:Thermistor - ±0.2°C, 0...70°C RTD - Class A ±0.15°C @ 0°C, ±0.35°C @ 100°C Housing:150mm x 6mm Stainless steel probe, Cable PVC 8mm OD outer sleeve Protection:IP68 Termination: 5 metres of PVC Flying lead Ambient: 0°C to +50°C, 0-95% RH non-condensing T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Part Code Description TE-FLT/IM/5 10K3A1, Trend TE-FLA/IM/5 10K4A1, Andover, Delta TE-FLH/IM/5 20K6A1, Honeywell TE-FL100/IM/5 PT100A TE-FL1K/IM/5 PT1000A, Cylon TE-FLLAN/IM/5 Ni1000 TK5000, Siemens TE-FLSAT/IM/5 Satchwell TE-FLTAC/IM/5 1.8K3A1, TAC TE-FL3K/IM/5 3K3A1, Alerton TE-FLD/IM/5 30K6A1, Drayton TE-FLP/IM/5 50K6A1, Priva E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Description Part Code Description TE-FLT 10K3A1, Trend TE-FLA 10K4A1, Andover, Delta TE-FLH 20K6A1, Honeywell TE-FL100 PT100A TE-FL1K PT1000A, Cylon TE-FLLAN Ni1000 TK5000, Siemens TE-FLSAT Satchwell TE-FLTAC 1.8K3A1, TAC TE-FL3K 3K3A1, Alerton TE-FLD 30K6A1, Drayton TE-FLP 50K6A1, Priva TE-FLx-5 5 metre cable Part Code Description TE-FX/T 10K3A1, Trend TE-FX/A 10K4A1, Andover, Delta TE-FX/H 20K6A1, Honeywell TE- FX/100 PT100A TE- FX/1K PT1000A, Cylon •Flexible plastic probe TE-FX/LAN Ni1000 TK5000, Siemens •Round conduit box mounting. TE-FX/SAT Satchwell •Adjustable length. TE-FX/TAC 1.8K3A1, TAC •Supplied with 1.5M flying lead TE-FX/3K 3K3A1, Alerton TE-FX/D 30K6A1, Drayton TE-FX/P 50K6A1, Priva The TE-FL range of flying lead temperature sensors are designed to interface with a wide variety of HVAC control equipment. Units are available with a high quality thermistor element or platinum element. The sensor is housed in a plastic cap with 2 or 5 metres of cable. Features •2 and 5 metre cable options •Plastic sensor cap •Wide choice of sensor options Technical Specification Sensor Type: Thermistor or RTD element Accuracy: Thermistor - ±0.2°C, 0...70°C RTD - Class A ±0.15°C @ 0°C, ±0.35°C @ 100°C Housing: Plastic cap 6mm x 20mm Protection:IP30 Termination: 2 or 5 metres of PVC flying lead Ambient: 0°C to +50°C, 0-95% RH non-condensing Flexible Ceiling Mount Probe TE-FX Description The TE-FX Flexible probe is designed to mount vertically from a ceiling where there could be movement of large objects such as freezer cabinets in Supermarkets, they can be simply pushed out of the way without fear of damage or breakage Features Technical Specification Sensor Type: Thermistor or RTD element Accuracy: Thermistor - ±0.2°C, 0...70°C RTD - Class A ±0.15°C @ 0°C, ±0.35°C @ 100°C Housing: White ABS housing and White Butyrate Tube 9.5mm dia x 700mm Protection:IP30 Termination: 1.5 Meters of PVC lying lead Ambient: 0°C to +50°C, 0-95% RH non-condensing T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Flexible temperature sensors Flying Lead Temperature Sensors TE-FLx Flying lead temperature sensors E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 77 E.C.Products Building Management Controls & Peripherals Duct temperature sensors E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Duct Temperature Sensors TE-Dx Description Technical Specification The TE-D range of duct temperature sensors are designed to interface with a wide variety of HVAC control equipment. Units are available with a high quality thermistor element or platinum element. Sensor Type: Thermistor or RTD element Accuracy: Thermistor - ±0.2°C, 0...70°C RTD - Class A ±0.15°C @ 0°C, ±0.35°C @ 100°C Housing: Flame retardant ABS Probe: 6mm diameter stainless steel 150mm or 450mm Protection:IP65 Terminals: Rising clamp 0.5-2.5mm² cable Ambient: –20°C to +85°C, 0-95% RH non-condensing The housing has a quick release lid for ease of installation and gasket for sealing to the duct. The probe is stainless steel for maximum corrosion resistance and is available in two standard lengths. Features •IP65 Flame retardant ABS housing •Stainless steel probe •Wide choice of sensor options Part Code Description TE-DT 10K3A1, Trend TE-DA 10K4A1, Andover, Delta TE-DH 20K6A1, Honeywell TE-D100 PT100A TE-D1K PT1000A, Cylon TE-DLAN Ni1000 TK5000, Siemens TE-DSAT Satchwell TE-DTAC 1.8K3A1, TAC TE-D3K 3K3A1, Alerton TE-DD 30K6A1, Drayton TE-DP 50K6A1, Priva TE-Dx/450 450mm Long Probe For other lengths add length to end of Part number when ordering. Lengths available from Stock 50, 65, 75, 100, 200, 250, 300, 350, 400, 500, 600, 700, 800, 1000mm 78 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Immersion Temperature Sensors TE-Ix Description Part Code Description The TE-I range of immersion temperature sensors are designed to interface with a wide variety of HVAC control equipment. Units are available with a high quality thermistor element or platinum element. TE-IT 10K3A1, Trend TE-IA 10K4A1, Andover, Delta TE-IH 20K6A1, Honeywell The housing has a quick release lid for ease of installation and gasket for sealing to the duct. The probe is stainless steel for maximum corrosion resistance and brass or stainless steel pockets are available. TE-I100 PT100A TE-I1K PT1000A, Cylon TE-ILAN Ni1000 TK5000, Siemens TE-ISAT Satchwell TE-ITAC 1.8K3A1, TAC TE-I3K 3K3A1, Alerton TE-ID 30K6A1, Drayton TE-IP 50K6A1, Priva Features •IP65 Flame retardant ABS housing •Stainless steel probe •Brass or Stainless Steel Pocket •Wide choice of sensor options For other lengths add length to end of Part number when ordering. Lengths available from Stock 50, 65, 75, 100, 200, 250, 300, 350, 400, 500, 600, 700, 800, 1000mm Technical Specification Immersion temperature sensors E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Sensor Type: Thermistor or RTD element Accuracy: Thermistor - ±0.2°C, 0...70°C RTD - Class A ±0.15°C @ 0°C, ±0.35°C @ 100°C Housing: Flame retardant ABS Probe: 6mm diameter stainless steel 150mm Pocket: Brass or Stainless Steel ½” BSPT thread Protection:IP65 Terminals: Rising clamp 0.5-2.5mm² cable Ambient: –20°C to +85°C, 0-95% RH non-condensing Immersion Pockets TE-IxP Description Technical Specification This range of immersion sensor pockets are designed to be screwed directly into pipework to provide a dry environment for immersion temperature sensors. Pockets are available in both brass and 316 stainless steel. Brass pockets are recommended for use with standard LPHW and DHWS systems whilst stainless steel variants can be used on high temperature and pressure installations (including steam) and are also recommended for chilled water and other low temperature applications. Features •½” BSPT threaded connection •Brass or Stainless Steel versions •Suitable for ECP range of immersion sensors Materials: TE-IBP: Brass TE-ISP: 316 Stainless Steel Max System Pressure: TE-IBP: 10 bar TE-ISP: 16 bar Operating Temp. Range: TE-IBP: 0°C to +110°C TE-ISP: –20°C to +400°C Dimensions: Boss: 1/2” BSPT Probe: 110mm x 8mm OD (6mm ID) Overall Length: 148mm Country of Origin: India Part Code Description TE-IBP Brass Immersion Pocket TE-ISP Stainless Steel Immersion Pocket For other lengths add length to end of Part number when ordering. Lengths available from Stock 50, 65, 75, 100, 200, 250, 300, 350, 400, 500, 600, 700, 800, 1000mm T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 79 E.C.Products Building Management Controls & Peripherals Window temperature sensors Strap-on temperature sensors E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 80 Strap-on Temperature Sensors TE-Sx Description Technical Specification The TE-S range of strap-on temperature sensors are designed to interface with a wide variety of HVAC control equipment. Units are available with a high quality thermistor element or platinum element. The housing has a quick release lid for ease of installation and the sensor is housed in a shaped copper lug for surface temperature measurement. Features •IP65 Flame retardant ABS housing •Copper lug for surface attachment •Wide choice of sensor options Sensor Type: Thermistor or RTD element Accuracy: Thermistor - ±0.2°C, 0...70°C RTD - Class A ±0.15°C @ 0°C, ±0.35°C @ 100°C Housing: Flame retardant ABS Probe: 6mm dia. shaped copper 50mm long with 1m cable Protection:IP65 Terminals: Rising clamp 0.5-2.5mm² cable Ambient: –20°C to +85°C, 0-95% RH non-condensing Part Code Description TE-ST 10K3A1, Trend TE-SA 10K4A1, Andover, Delta TE-SH 20K6A1, Honeywell TE-S100 PT100A TE-S1K PT1000A, Cylon TE-SLAN Ni1000 TK5000, Siemens TE-SSAT Satchwell TE-STAC 1.8K3A1, TAC TE-S3K 3K3A1, Alerton TE-SD 30K6A1, Drayton TE-SP 50K6A1, Priva Window Surface Temperature Sensors TE-OFTFx Description Technical Specification Small surface-contacting resistance thermometer in aluminium enclosure. It is used for temperature detection on flat or slightly convex surfaces, for instance for measuring surface temperatures of windows, for monitoring formation of condensate, or as heating surface feeler, e.g. at windows or walls. Features •Wide choice of sensor options Part Code Description TE-OFTF/T 10K3A1, Trend TE-OFTF/A 10K4A1, Andover, Delta TE-OFTF/H 20K6A1, Honeywell TE-OFTF/100 PT100A TE-OFTF/1K PT1000A, Cylon TE-OFTF/LAN Ni1000 TK5000, Siemens TE-OFTF/TAC 1.8K3A1, TAC T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Measuring range: –30...+ 105 °C Sensor Type: Thermistor or RTD element Accuracy: Thermistor - ±0.2°C, 0...70°C, RTD - Class A Process connection: To be attached to the surface measured using appropriate adhesive Protective sleeve:Aluminium Dimensions: 8 x 8 x 40 mm Connecting cable: PVC; 1.5 m, LiYY, 2 x 0.25 mm² Humidity: < 95 % r. H. Protection type: IP 54 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 4...20mA Temperature Sensors TE-x420 Description Technical Specification The TE-420 range of temperature sensors are designed to interface with a wide variety of HVAC control equipment. Units are available with a high quality PT100 platinum element and 4...20mA output transmitter which is supplied in a default range but can be re-programmed to suit any temperature range required. Units are available in most sensor styles shown in this catalogue. For flue gas sensor scaling can be between -200 to 400°C. Features Sensor Type: PT100 100Ω @ 0°C, 2 or 3 wire, Class A Output: 2 wire 4...20mA current loop Accuracy: 0.1°C ±0.05% of reading + sensor accuracy Power Supply:10...30Vdc Loop Voltage Effect: 0.2 uA/V Thermal Drift: 1 uA/°C Max. Output Load: 700Ω @ 24Vdc 4–20mA Temperature E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH •4...20mA loop powered output •Range can be reprogrammed by the user •Choice of sensor styles Part Code Description TE-R420 Space Temperature Sensor –10°C…+40°C TE-D420 Duct Temperature Sensor –10°C…+40°C TE-I420 Immersion Temperature Sensor –10°C…+110°C TE-S420 Strap-on Temperature Sensor –10°C…+110°C TE-O420 Outside Air Temperature Sensor –10°C…+40°C TE-T420* Thimble Temperature Sensor –10°C…+40°C TE-T420/B* Brass Thimble Temperature Sensor –10°C…+40°C TE-T420/AL* Aluminium Thimble Sensor –10°C…+40°C TE-T420/SS* St. Stl. Thimble Temperature Sensor –10°C…+40°C TE-FL420* Flying Lead Temperature Sensor –10°C…+40°C TE-FG420 Flue gas sensor, specify Scaling when ordering * Units supplied complete with junction box T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 81 E.C.Products Building Management Controls & Peripherals Temperature charts E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Temperature Sensor Compatibility Chart Element Type Room Aquatrol Honeywell 10K3A1 Type T 10K4A1 Type A 20K6A1 Type H PT100 Type 100 PT1000 Type 1K Outside • T8120B Johnson • Satchwell • Duct • T7416A T7043E Immersion Bullet • • • • T7106A T7043F T7044C • • • • • TE-6361V TE-636GV-1 • Clamp DOT10K2 DOS10K2 DDT10K1 DWT10K1 DST10K1 • T7076D Seachange SEN/PTR/ROM SEN/PR/OAT SEN/PR/DCT SEN/PR/IMM SEN/PR/CLP Trend TE-TS TE-TO TE-TD TE-TI TE-TC • Andover TTS-S Series TT-O Series TT-I Series TT-ST • • SEN/FL Delta Controls • • • • • • Siebe • • • • • • York <40°C • • • • • • Honeywell T7460H, T7470A, DRF20-S, RF20 T4712 VF20T, VF20NT, VF20L, VF20LN, WPF20, T7425A VF20A, WPF20A Sauter EGT430/F011 • • • • Serck AF20, DAF20, T7416A1022 EGT466/F011 EGT447/F011 • • LF20 • • Siemens/ Landis & Staefa QAA100 QAA2010 QAC2010 FK-TP/200 QAM2110 QAE2110 Honeywell T7412 T7416A1014 T7411 T7413 Sauter EGT430/F101 EGT401/F101 EGT446/F101 EGT447/F101 • KFT20, KFT20B, DKF20 EGT456/F011 • QAP2010 T7414 • EGT411/F101 EGT456/F101 Serck • • • • • • Siebe TS-5811 • • • • • Cylon • • • • • • Ni1000 Type N1K Sauter EGT330/F101 EGT301/F101 EGT346/F101 EGT347/F101 EGT348/F101 EGT346/F101 EGT347/F101 EGT348/F101 EGT311/F101 EGT354/F101 EGT356/F101 Ni1000/ TK5000 Type LAN Siemens/ Landis & Staefa QAA24/25/ 26/27, QAA64 QAC22 QAM2120 QAE2120 QAD22 QAD26 QAP21 QAP22 QAZ21 SAT Satchwell DRT, DU, DUS, DUSF DOT0002 DOS0002 DDT0001 DWT0001 DST0001 TAC TAC • DDU • • • • • • Alerton MS-1000 Series, TS-1050 • • • • • 30K6A1 Type D Drayton A701 50K6A1 Type P Ambiflex • • • • • • 100K6A1 Type Y York >40°C • • • • • • Barber Colman • • • • • • Siebe • • • • • • 3K3A1 Type 3K SIE 82 Manufacturer T: +44 (0)20 8569 4100 A702 • F: +44 (0)20 8569 4111 A703 A704 E: sales@ecproducts.co.uk • W: www.ecproducts.co.uk Temperature Sensor Resistance Characteristics 10K3A1 - Type T 10K4A1 - Type A Thermistor, temp coef. -ve Thermistor, temp coef. -ve Temp°C –50 –40 –30 –20 –15 –10 –5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 Ω 667828 335671 176683 96974 72895 55298 42314 32650 31030 29500 28054 26688 25396 24173 23016 21921 20885 19904 18974 18092 17257 16465 15714 15001 14325 13623 13053 12494 11943 11420 10923 10450 10000 9572 9165 8777 8408 8056 6530 5325 4367 3601 2985 2487 2082 1751 1480 1256 1070 916.1 787.0 678.6 587.3 510.1 444.5 388.6 340.8 300.0 234.1 184.8 – – – – – Temp°C –50 –40 –30 –20 –15 –10 –5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 T: +44 (0)20 8569 4100 Ω 441667 239831 135233 78930 61030 47549 37316 29490 28157 26891 25689 24547 23462 22430 21450 20517 19631 18787 17983 17219 16490 15797 15136 14507 13906 13334 12788 12268 11771 11297 10845 10413 10000 9606 9229 8869 8525 8197 6754 5594 4656 3893 3271 2760 2339 1990 1700 1458 1255 1084 939.6 817.2 713.0 624.1 547.9 482.5 426.0 377.2 298.1 238.0 – – – – – 20K6A1 - Type H PT100A - Type 100 PT1000A - Type 1K Thermistor, temp coef. -ve Thermistor, temp coef. +ve Thermistor, temp coef. +ve Temp°C 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 F: +44 (0)20 8569 4111 Ω 71120 67324 63749 60385 57218 54397 51429 48032 46258 43938 41719 39640 37676 36020 34067 32409 30841 29388 27954 26625 25387 24178 23047 21977 20962 20000 19085 18225 17404 16824 16384 16189 14491 13847 13235 12654 12010 11578 11076 10600 10148 9721.1 9314.5 8826.8 8557.5 8205.3 7899.3 7548.9 7243.1 6951.2 6672.6 6404.0 6148.9 5904.6 5671.4 5448.6 5235.7 5092.3 4837.8 4651.6 4473.9 – – – – Temp°C –50 –40 –30 –20 –15 –10 –5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 401 402 403 E: sales@ecproducts.co.uk Ω 80.3 84.3 88.2 92.2 96.1 100.0 103.9 107.8 109.8 111.7 115.5 119.4 123.2 127.1 130.9 134.7 138.5 142.3 146.1 149.8 153.6 157.3 161.0 164.8 168.5 172.2 175.8 179.5 183.2 186.8 190.5 194.1 197.7 201.3 204.9 208.5 212.0 215.6 219.1 222.7 226.2 229.7 233.2 236.7 240.1 243.6 247.0 – – – Temp°C –50 –40 –30 –20 –15 –10 –5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390 400 401 402 403 Ω 803 843 882 921 961 1000 Temperature charts E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 1039 1078 1117 1155 1194 1232 1271 1309 1347 1385 1423 1461 1498 1536 1573 1611 1648 1685 1722 1758 1795 1832 1868 1905 1941 1977 2013 2049 2085 2121 2156 2191 2227 2262 2297 2332 2367 2401 2436 2470 – – – W: www.ecproducts.co.uk 83 E.C.Products Building Management Controls & Peripherals Temperature charts E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 84 Temperature Sensor Resistance Characteristics NI1000 - Type NIK Thermistor, temp coef. +ve Temp°C –50 –40 –30 –20 –15 –10 –5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 201 202 203 204 205 Ω 743 791 842 893 946 1000 1056 1112 1171 1230 1291 1353 1417 1483 1549 1618 1688 1760 1833 1909 1987 2066 2148 2232 – – – – – – – Ni1000/TK5000 Type LAN Thermistor, temp coef. +ve Temp°C –50 –40 –30 –20 –15 –10 –5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 150 170 180 190 T: +44 (0)20 8569 4100 Ω 790.8 826.8 871.7 913.4 934.7 956.2 978.0 1000.0 1004.4 1008.9 1013.3 1017.8 1022.3 1026.7 1031.2 1035.8 1040.3 1044.8 1049.3 1053.9 1058.4 1063.0 1067.6 1072.2 1076.8 1081.4 1086.0 1090.7 1095.3 1100.0 1104.6 1109.3 1114.0 1120.0 1123.4 1128.1 1132.9 1137.6 1161.5 1185.7 1210.2 1235.0 1260.1 1285.4 1311.1 1337.1 1363.5 1390.1 1417.1 1444.4 1472.0 1500.0 1528.3 1557.0 1586.0 1625.4 – – – – – – – – Type SAT Type TAC 3K3A1 - Type 3K Thermistor, temp coef. -ve Thermistor, temp coef. -ve Thermistor, temp coef. -ve Temp°C –50 –40 –30 –20 –15 –10 –5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 F: +44 (0)20 8569 4111 Ω 9719 9584 9349 8968 8708 8396 8031 7614 7525 7434 7341 7246 7150 7053 6954 6853 6752 6649 6545 6440 6334 6228 6121 6013 5905 5786 5684 5580 5471 5362 5254 5147 5039 4933 4827 4721 4617 4513 4012 3545 3117 2730 2386 2082 1816 1585 1385 1213 1064 937 828 734 654 585 525 474 429 391 329 281 – – – – – Temp°C 0 5 10 15 20 25 30 35 40 50 60 70 80 90 100 110 120 130 E: sales@ecproducts.co.uk Ω 5085 4078 3294 2676 2188 1800 1488 1237 1034 740 540 400 300 230 180 – – – Temp°C –50 –40 –30 –20 –15 –10 –5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 Ω 200348 100701 53005 29092 21868 16589 12694 9795 9309 8850 8416 8006 7619 7252 6905 6577 6266 5971 5692 5428 5177 4940 4714 4500 4297 4105 3916 3748 3583 3426 3277 3135 3000 2871 2749 2633 2522 2417 1959 1598 1310 1080 895.5 746.2 624.7 525.5 444.0 376.9 321.2 274.8 236.1 203.6 176.2 153.0 133.3 116.6 102.2 89.95 70.23 55.44 – – – – – W: www.ecproducts.co.uk Temperature Sensor Resistance Characteristics 30K6A1 - Type D 50K6A1 - Type P 100K6A1 - Type Y Type SIE Thermistor, temp coef. -ve Thermistor, temp coef. -ve Thermistor, temp coef. -ve Thermistor, temp coef. -ve Temp°C –50 –40 –30 –20 –15 –10 –5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 Ω 2497K 1219K 622911 331876 245785 183697 138502 105305 99787 94588 89689 85069 60713 76604 72726 69064 65608 62347 59257 56346 53585 50978 48511 46178 43969 41877 39895 38019 36240 34554 32955 31438 30000 28635 27339 26108 24939 23828 19046 15317 12390 10079 8243 6777 5600 4650 3879 3251 2737 2313 1963 1672 1430 1228 1058 914.6 793.2 690.2 527.4 407.7 - T: +44 (0)20 8569 4100 Temp°C –50 –40 –30 –20 –15 –10 –5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 Ω 4168K 2033K 1038K 553243 409689 306183 230842 175508 166310 157644 149480 141779 134521 127669 121207 115105 109344 103903 98761 93901 89307 84962 80851 76961 73280 69794 66492 63364 60400 57589 54925 52398 50000 47724 45564 43513 41565 39714 31744 25529 20650 16799 13740 11297 9334 7751 6466 5419 4560 3855 3271 2787 2384 2046 1762 1523 1321 1149 878.2 678.8 – – – – – F: +44 (0)20 8569 4111 Temp°C –50 –40 –30 –20 –15 –10 –5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 Ω 8337K 4067K 2077K 1106K 819378 612366 461683 351017 332619 315288 298959 283558 269041 255337 242414 230210 218688 207807 197521 187803 178613 169924 161702 153923 146560 139588 132984 126729 120799 115179 109850 104796 100000 95449 91128 87026 83129 79428 63489 51058 41301 33598 27479 22593 18669 15502 12932 10837 9121 7710 6543 5574 4767 4092 3525 3047 2642 2299 1756 1357 – – – – – E: sales@ecproducts.co.uk Temp°C –50 –40 –30 –20 –15 –10 –5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 140 150 160 170 180 190 200 Ω 10732 10517 10172 9654 9320 8933 8496 8044 7910 7807 7702 7596 7489 7381 7271 7161 7050 6938 6825 6712 6598 6485 6370 6256 6141 6028 5913 5798 5686 5573 5461 5349 5238 5128 5019 4910 4803 4696 4185 3707 3271 2875 2521 2206 1929 1685 1472 1287 1127 986 866 760 670 590 522 462 410 365 290 233 – – – – – W: www.ecproducts.co.uk Temperature charts E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 85 E.C.Products Building Management Controls & Peripherals Thermostats E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Frost Protection Thermostat TS-FS Description Technical Specification The TS-FS frost protection thermostats provide a switched output based on the average temperature detected along a six metre capillary sensor. The unit is fixed across a duct using capillary clips, downstream of the frost coil and is used to prevent the icing up of filters, fans and coils. Features •Auto or manual reset versions •6 metre capillary •24A @ 240Vac switch rating Part Code Description TS-FS-A Auto Reset Frost Protection Thermostat TS-FS-M Manual Reset Frost Protection Thermostat TS-FS-A-IP65 Auto Reset Frost Protection Thermostat IP65 TS-FS-M-IP65 Manual Reset Frost Protection Thermostat IP65 TS-FS-FC Capillary Fixing Clips Control range: Differential: Switch rating: Reset: Capillary: Sensor Type: Ambient range: Protection: –30°C to +15°C TS-FS-A - 1.5...16°C TS-FS-M - Fixed 2.5°C 24(10)A @ 230Vac 3A @ 24Vdc FS-A: Auto FS-M: Manual 6m x 2mm dia copper Vapour Charge Housing: 0°C to 50°C Capillary: –50...+70°C IP44 (IP65 to order) Outside Frost Stat TS90-B3 Description Technical Specification Outside wall mount frost protection thermostat. Part Code Description TS90-B3 Outside frost Thermostat Contact current rating:SPDT contact, 250V 10Amp on Opening Contact, 3A amp on closing contact Differential:0.5°C Range:–5-25°C Protection:IP65 Dimensions:160x120x75mm Tamperproof Thermostat TY90-T Description Technical Specification Wall mount bimetallic thermostat with concealed adjustment for heating and cooling applications. 86 Part Code Description TY90-T Tamperproof Thermostat T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Contact current rating:SPDT contact, 250V 10Amp on Opening Contact, 3A amp on closing contact Differential:0.5°C Range:5-35°C E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Strap-on Thermostat WRP90GD Description Technical Specification The WRP90GD is a thermostat suitable for mounting on pipes or cylinders. The unit has an exposed setpoint adjustment knob and comes complete with fixing strap for mounting the unit and ensuring good surface contact. Temperature Range:10...90°C Differential:5°C Contact Rating: 15(2.5)A @ 250Vac SPDT Protection:IP20 Thermostats E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Features •SPDT Contacts •Complete with fixing Strap Part Code Description WRP90GD Strap-on/Cylinder Thermostat Room Thermostat TR101X Description Technical Specification The TR101X is a thermostat suitable for room temperature monitoring and is wall mounting. The unit has an exposed setpoint adjustment knob and comes with SPDT contacts for heating/cooling applications. Features Contact Type: SPDT (Heating/Cooling) Contact Rating: 16(4)A @ 250Vac Temperature Range:10...30°C Differential:1°C Ambient Storage: –20…+50°C, 0...90% RH •SPDT Contacts •Exposed Setpoint Knob Part Code Description TR101X Room Thermostat T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 87 E.C.Products Building Management Controls & Peripherals Thermostats E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Large LCD Screen Digital Programmable Thermostat T-908WHB-3-xx Description Technical Specification 5 + 1 + 1 day 2 Wire Volt Free. Heat/Cool. 24/250v 5 Amp (Battery Operated) Room Thermostat, wireless option available. Features •Large LCD display with backlight •Set points and room temperature display simultaneously •Maintains the temperature within the range of 0.5ºC to the set point •Automatic fan with adjustable 3-fan speed. •Manual change over •Never lose user setting in the event of power-off, no battery is required •Display temperature recalibrates •Sleep mode option Part Code Description T-908WHB-3-B Large LCD Screen Digital Programmable Thermostat T-908WHB-3-RF Wireless Large LCD Screen Digital Programmable Thermostat Power source: Control Centre 2 AA batteries Receiver 230VAC 50HZ Frequency band: 433 MHZ (for wireless version only) Relay contact: 230VAC 16A Room temp. setting range:Deg C to 35ºC Accuracy:±0.5ºC Dimensions: Control Centre: 115×90×16mm Receiver: 88x88×40mm Simple Wireless RF Room Thermostat Volt Free Description Technical Specification Wireless digital thermostat, push button or dial set point Features •Simple to use •Display set point and room temperature •Thermostat sender battery operated 88 Part Code Description DRF1 Push button wireless digital thermostat CC816-RF Dial wireless digital thermostat T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Frequency band: 433 MHZ Room temp. setting range:5ºC to 35ºC Accuracy:0.5ºC Receiver Input Voltage: 240VAC 50HZ Receiver Output Voltage: 24..240VAC 50HZ 10(3)A Max Operating Temperature: 0ºC to 50ºC Dimensions: Control Centre: 82×88×25mm Receiver: 82×82×32mm Color:White E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Digital Electronic Thermostat 2-8 Stage TS-ET2 Description Technical Specification The TS-ET2 is a 2-8 Stage Programmable Electronic Thermostat with the option of a remote Set point, Low Limit and Setback, compatible with Building Management Systems. The unit can control up to 8 stages of heating or cooling. Features •Wide temperature range •Night setback input •Heating or cooling function •2 line, 32 character display •Adjustable stage and inter-stage differential •Din rail mounting •4 models available Part Code Description TS-ET2 2 Stage Electronic Thermostat TS-ET4 4 Stage Electronic Thermostat TS-ET6 6 Stage Electronic Thermostat TS-ET8 8 Stage Electronic Thermostat T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Temp sensor: 10K3A1thermistor for control and frost override Temprange:–20°C to +95°C Differential range:1°C to 10°C Temp Override:20°C to +95°C Night set back: volt free contact Offset pot 1K-11K, range –4°C to +4°C of set point External set point:1k-11k Output:2 SPCO contacts per 2 stager 10A resistive 230Vac Dimensions: 137W x 75H x 62H E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Thermostats E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 89 E.C.Products Building Management Controls & Peripherals Thermostats E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Wall Mount/Greenhouse Thermostat TS-DBET Description Technical Specification Well-suited for heating, cooling and air conditioning systems in dusty, damp and strong polluted areas: industrial areas, commercial buildings, storage room, garages, machine rooms, factories, greenhouses and agricultural installations. Features •Exposed adjustment knob •Suitable for many applications Part Code Description TS-DBET-22 Wall Mounted Thermostat –30°C…+30°C TS-DBET-060 Wall Mounted Thermostat 0°C…+60°C Sensitive element: Liquid-filled coiled copper bulb Contacts: SPDT contacts (heat/cool) Switch capacity: 15(8)A @ 24...250 Vac Differentials: TS-DBET-22 - adjustable 1...15K TS-DBET-090 - fixed 1.5K Working: –35...+60°C, 10...90% RH (non condensing) Storage: 40...+60°C, < 95% RH Housing: Byblend base, ABS cover Protection:IP65 Size: 108 x 70 x 72 mm Weight: 450 g Capillary Thermostats TS-DBTC Description Technical Specification Temperature measurement and monitoring in normal fluids (water) and in non aggressive gases with a thermo sensitive element coated with PVC. Well-suited for heating, cooling and air conditioning systems in domestic areas; industrial areas; commercial buildings and sport halls. Features •Exposed adjustment adjustment knob •1.5 metre capillary •SPDT Contacts 90 Part Code Description TS-DBTC-060 Capillary Thermostat 0°C…+60°C TS-DBTC-090 Capillary Thermostat 0°C…+90°C T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Sensitive element: Liquid-filled coiled copper bulb with 1.5m length capillary PVC protected bulb: Ø6.8 Contacts: SPDT contacts(heat/cool) Switch capacity: 16(4)A@ 250 Vac Differential: Fixed 3K Working: –10...+65 °C 0...90% RH Storage: –40...+70 °C < 95% RH. Housing: Byblend base, ABS cover Protection:IP54 Size: 108 x 70 x 72 mm Weight: 360 g E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Immersion Thermostats TS-DBTV Description Technical Specification Temperature control in pipes with normal fluids (water) for heating, cooling and air conditioning systems, boilers and heaters. Temperature monitoring and safety protection with manual reset and signal contact. Well-suited for general applications in strong polluted domestic and industrial areas. Features •Concealed Adjustment Knob •Supplied with pocket •SPDT Contacts Part Code Description TS-DBTV-090U Immersion Thermostat 0°C…+90°C TS-DBTV-11 Immersion Thermostat +50°C…+120°C Sensitive element: Contacts: Switch capacity: Differentials: Working: Storage: Housing: Protection: Size: Weight: Copper bulb with 120 mm pocket SPDT contacts(heat/cool) 15(8)A @ 24...250 Vac Fixed 3K –35...+65 °C,10...90% RH –40...+70 °C, < 95% RH Byblend base, ABS cover IP65, class I 108 x 70 x 72 mm 570 g Thermostats E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Duct Thermostats TS-DBTZ Description Technical Specification Temperature monitoring in air or non aggressive gas ducts. Well-suited for general applications in strong polluted domestic and industrial areas. Features •Concealed Adjustment Knob •Integrated bulb holder •SPDT Contacts Part Code Description TS-DBTZ-2U Duct Thermostat –30°C…+30°C TS-DBTZ-090U Duct Thermostat 0°C…+90°C T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Sensitive element: Liquid-filled coiled copper bulb with 200mm protection spring and mounting bracket Contacts: SPDT contacts (heat/cool) Switch capacity: 15(8)A @ 24...250 Vac Differentials:1/3K Working: –35...+65°C,10...90% RH Storage: –40...+70°C, < 95% RH Housing: Byblend base, ABS cover Protection:IP65 Size: 108 x 70 x 72 mm Weight: 690 g E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 91 E.C.Products Building Management Controls & Peripherals Thermostats E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Cost Effective Industrial Thermostats TS Description Technical Specification This range of industrial thermostats are suitable for applications in boiler rooms and plant rooms where cost is critical, rated to IP40 they are suitable for indoor applications only. The Immersion Thermostats are supplied with 120mm Pocket ½” BSP fitting and a cable restraint with external adjustment. For Duct mounting a vented duct tube can be ordered separately IP Rating: IP40 Immersion and capillary. Space IP55 Current Rating: NC16(3)A @250Vac/NO 6(1)A @ 250Vac Switching Tolerance:±5% Differential:2-5°C Ambient:90°C The Capillary thermostat has a 1.5 meter capillary with a 6.5mm diameter bulb, external adjustment and a cable restraint. The Industrial Space thermostat is IP55 rated with concealed adjustment, it has a Stainless Steel coiled Capillary and is ideally suited for use in green houses and farm buildings. Features •Large LCD display with backlight •Set points and room temperature display simultaneously •Maintains the temperature within the range of 0.5ºC to the set point •Automatic fan with adjustable 3-fan speed. •Manual change over •Never lose user setting in the event of power-off, no battery is required •Display temperature recalibrates •Sleep mode option 92 Part Code Description TS9510-01 Immersion Thermostat 0-60°C TS9510-02 Immersion Thermostat 0-90°C TS9510-03 Immersion Thermostat 30-120°C TS95H30-54 Immersion Thermostat 20-70°C manual High Limit 85°C TS9520-01 Capillary Thermostat 0-60°C TS9520-02 Capillary Thermostat 0-90°C TS9520-04 Capillary Thermostat -35+35°C TS9502-01 Industrial Space Thermostat 5-60°C TS9502-02 Industrial Space Thermostat -35+35°C TS-DFK Vented Duct Mounting Flange T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Terminal Unit Valves VFX Description Technical Specification The VFX valves are used in heating, cooling and air conditioning systems. The valves are normally closed and are compact, reliable and easily mounted. A plastic cap is available that ensures stem protection and for manual adjustment. A range of Electrothermal Actuators is also available to be used with the VFX valve bodies. Nominal Pressure:PN16 Stroke:2.5mm Regulation Mode:Linear Leakage: Perfect sealing Valve Body: Forged brass Stem and Plug: PA + GF Stem Gland Seal: FKM “o” ring Max. ΔP: 2.5 bar Fluids: Water with max. 40% glycol Fluid Temperature:+2…+95°C Actuator: SE1 series electrothermal Features •Connection between actuator and valve by threaded male M30x1.5 ring nut •2, 3 & 4 port versions available •Choice of Kvs values and threads Part Code Description VFX214 2 Port ½” Valve Body 1.6 Kvs for use with SE1 Actuators VFX235 2 Port ¾” Valve Body 2.5 Kvs for use with SE1 Actuators VFX314 3 Port ½” Valve Body 1.6 Kvs for use with SE1 Actuators VFX335 3 Port ¾” Valve Body 2.5 Kvs for use with SE1 Actuators VFX414 4 Port ½” Valve Body 1.6 Kvs for use with SE1 Actuators VFX435 4 Port ¾” Valve Body 2.5 Kvs for use with SE1 Actuators Fan coil valves E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Terminal Unit Valve Actuators SE1 Description Technical Specification The SE1Electrothermal Actuators are for use with the VFX range of fan coil valves and are used in heating, cooling and air conditioning systems. When the actuators are not energized the valves are normally closed and two action types are available: on-off and modulating 0...10Vdc.Assembly is easy using the metal ring and tools are necessary. The actuator is fitted with valve position indication. Features •Connection between actuator and valve by threaded male M30x1.5 ring nut •On-off 0...10Vdc modulating versions •24Vac and 230Vac versions Power Supply: SE1M24, SE1T24: 24Vac ±10% 50Hz SE1T230: 230Vac ±10% 50Hz Power: SE1M24: 3.5VA SE1T24, SE1T230: 3VA Peak Current: SE1M24, SE1T24: < 0.25A SE1T230: < 0.70A Sensing Element: Special Wax Running Time: 210 seconds Wiring: 2 metre PVC cable Connection: Metal ring nut M30 x 1.5 Working Temp:0...50°C Working Humidity: 10...90% RH non-condensing Storage:–20…+70°C Protection:IP44 Weight:200g Part Code Description SE1T24 24V On/Off Electrothermal Actuator SE1T230 230V On/Off Electrothermal Actuator SE1M24 24V Proportional 0...10Vdc Electrothermal Actuator T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 93 E.C.Products Building Management Controls & Peripherals Fan coil valves E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Fan Coil Valves V5000 Description The V5000 valves are primarily designed to regulate the flow of water and steam in response to the demand of a controller in zone and terminal unit applications. Features •Forged brass body, stainless steel stem and spring •Inherent flow characteristics: equal percentage •Rangeability 20:1 •M30 x 1.5 collar 2 way fan coil valves 3 way fan coil valve mixing/diverting with built in bypass Part Code Description V5510BC 15mm 3 Way Fan Coil Valve 0.4kvs By Pass 0.3kvs (DN10) V5510CC 15mm 3 Way Fan Coil Valve 0.63kvs By Pass 0.4kvs (DN10) V5510DC 15mm 3 Way Fan Coil Valve 1 kvs By Pass 0.63kvs (DN10) V5510EC 15mm 3 Way Fan Coil Valve 1.6kvs By Pass 1kvs (DN10) V5510JC 15mm 3 Way Fan Coil Valve 2.5kvs By Pass 1.6kvs (DN15) V5510KC 15mm 3 Way Fan Coil Valve 4kvs By Pass 2.5kvs (DN15) V5510MC 28mm 3 Way Fan Coil Valve 5kvs By Pass 3.5kvs (DN20) Part Code Description V5210ZC 15mm 2 Way Fan Coil Valve 0.16kvs (DN10) V5210BC 15mm 2 Way Fan Coil Valve 0.4kvs (DN10) V5210CC 15mm 2 Way Fan Coil Valve 0.63kvs (DN10) V5210DC 15mm 2 Way Fan Coil Valve 1kvs (DN10) V5210EC 15mm 2 Way Fan Coil Valve 1.6kvs (DN10) Part Code Description V5210JC 15mm 2 Way Fan Coil Valve 2.5kvs (DN15) V5590BC V5210KC 15mm 2 Way Fan Coil Valve 3.5kvs (DN15) 15mm 3 way Fan Coil Valve 0.4kvs By Pass 0.3 kvs Compression (DN10) V5210MC 28mm 2 Way Fan Coil Valve 4.5kvs (DN20) V5590CC 15mm 3 way Fan Coil Valve 0.63kvs By Pass 0.4 kvs Compression (DN10) Part Code Description V5590DC 15mm 3 way Fan Coil Valve 1kvs By Pass 0.63 kvs Compression (DN10) V5290BC 15mm 2 Way Fan Coil Valve 0.4kvs Compression (DN10) V5590EC 15mm 3 way Fan Coil Valve 1.6kvs By Pass 1kvs Compression (DN10) V5290CC 15mm 2 Way Fan Coil Valve 0.63kvs Compression (DN10) V5290DC 15mm 2 Way Fan Coil Valve 1kvs Compression (DN10) V5290EC 15mm 2 Way Fan Coil Valve 1.6kvs Compression (DN10 Actuators For use With V5000 Valves Part Code Description VA-7480-0001 24Vac Floating 12 sec/mm VA-7481-0001 24Vac Floating 8 sec/mm VA-7480-0003 230Vac Floating 12 sec/mm VA-7481-0003 230Vac Floating 8 sec/mm VA-7482-1001 24Vac/dc 0-10V 8 sec/mm Stroke Length 3.2mm VA-7482-2001 24Vac/dc 0-10V 8 sec/mm Stroke Length 4.3mm 94 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Pressure Independent Control valves VP1000 Description Technical Specification The VP1000 pressure independent control valve is a combination of a differential pressure regulator and a regulating valve for flow adjustment. Installation costs are considerably reduced as the valve performs the functions of two valves (balancing and adjustment). To adjust the flow rate, just set the selected value using the adjustment knob. Choosing the suitable valve is easy and fast. Flow rate is the only parameter to consider. Fluid Temperature:–10/+120°C Max. working pressure:2500kPa – 25 Bar (max) Fittings: BSP female threaded body. Collar: M30 x1.5 Features •Kvs calculation is not necessary •Valve authority calculation not required •Specific devices or knowledge are not necessary •Compact design •Flow rate adjustment without disassembling the actuators •Forged brass body •BSP fitting Part Code Body Flow rate VP100AAA 15mm 150 l/h – 0.042 l/s with pressure port VP101AAA 15mm 150 l/h – 0.042 l/s without pressure port VP100AAE 15mm 600 l/h – 0.167 l/s with pressure port VP101AAE 15mm 600 l/h – 0.167 l/s without pressure port VP100AAG 15mm 780 l/h – 0.217 l/s with pressure port VP101AAG 15mm 780 l/h – 0.217 l/s without pressure port VP100BAJ 20mm 1000 l/h – 0.278 l/s with pressure port VP101BAJ 20mm 1000 l/h – 0.278 l/s without pressure port VP100BAN 20mm 1500 l/h – 0.417 l/s with pressure port VP101BAN 20mm 1500 l/h – 0.417 l/s without pressure port VP100CAU 25mm 2200 l/h - 0.611 l/s with pressure port VP100CAW 25mm 2700 l/h – 0.750 l/s with pressure port VP100DAW 32mm 2700 l/h – 0.750 l/s with pressure port VP100DAY 32mm 3000 l/h – 0.833 l/s with pressure port Pressure independent valves E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Suitable actuators for pressure independent control valves Part Code Supply voltage Control Actuator speed VA-7481-0001 24Vac Floating 8 sec/mm VA-7481-0003 230Vac Floating 8 sec/mm VA-7482-1001 24Vac/dc Proportional 8 sec/mm T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 95 E.C.Products Building Management Controls & Peripherals Ball valves E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Belimo Control & Shut off Ball Valves Description Belimo Ball Valves, shut off and Characterised control valves with internal thread fitting for use on warm and cold water systems, bubble tight shut off. Shut off valves with Internal threads PN16 Part Code Description Part Code Description R2015-S1 2 Port Valve 15mm Kv 15 R3015-S1 3 Port Valve 15mm Kv 15 R2020-S2 2 Port Valve 20mm Kv 32 R3020-S2 3 Port Valve 20mm Kv 32 R2025-S2 2 Port Valve 25mm Kv 26 R3025-S2 3 Port Valve 25mm Kv 26 R2032-S3 2 Port Valve 32mm Kv 32 R3032-S3 3 Port Valve 32mm Kv 32 R2040-S3 2 Port Valve 40mm Kv 31 R3040-S3 3 Port Valve 40mm Kv 31 R2050-S4 2 Port Valve 50mm Kv 49 R3050-S4 3 Port Valve 50mm Kv 49 Characterised Control Valves with Internal Threads PN16 Part Code Description Part Code Description R2015-1P6-S1 2 Port Valve 15mm Kv 1.6 R3015-1P6-S1 3 Port Valve 15mm Kv 1.6 R2020-6P3-S2 2 Port Valve 20mm Kv 6.3 R3020-6P3-S2 3 Port Valve 20mm Kv 6 R2025-10-S2 2 Port Valve 25mm Kv 10 R3025-10-S2 3 Port Valve 25mm Kv10 R2032-16-S3 2 Port Valve 32mm Kv 16 R3032-16-S3 3 Port Valve 32mm Kv 16 R2040-25-S3 2 Port Valve 40mm Kv 25 R3040-25-S4 3 Port Valve 40mm Kv 25 R2050-40-S4 2 Port Valve 50mm Kv 40 R3050-40-S4 3 Port Valve 50mm Kv 40 Belimo Actuators for Ball Valves Part Code Description Part Code 3 point Open Close 96 Description Modulating TR230-3 S1 2 Nm Actuator 230Vac 3-Point for 15mm Valves TR24-SR S1 2 Nm Actuator 24Vac/dc Modulating 0-10vdc TR24 S1 2 Nm Actuator 24Vac/dc 3 Point for 15mm Valves LR24A-SR S2 5 Nm Actuator 24Vac/dc Modulating 0-10vdc LR230A S2 5 Nm Actuator 230Vac 3 Point for up to 25mm Valves LR24A S2 5 Nm Actuator 24Vac/dc 3 Point for up to 25mm Valves TRF230 S1 2 Nm Actuator 230Vac Open/Spring Return TRF24 S1 2 Nm Actuator 24Vac/dc Open/Spring Return NR24A-SR S3 10 Nm Actuator 24Vac/dc Modulating 0-10vdc SR24A-SR S4 20 Nm Actuator 24Vac/dc Modulating 0-10vdc Spring Return NR230A S3 10 Nm Actuator 230Vac 3 Point for up to 40mm Valves LRF230 S2 5 Nm Actuator 230Vac Open/Spring Return NR24A S3 10 Nm Actuator 24Vac/dc 3 Point for up to 40mm Valves LRF24 S2 5 Nm Actuator 24Vac/dc Open/Spring Return NRF230A S3 10 Nm Actuator 230Vac Open/Spring Return SR230A S4 20 Nm Actuator 230Vac 3 Point for up to 50mm Valves NRF24A S3 10 Nm Actuator 24Vac/dc Open/Spring Return TRF24-SR S1 2 Nm Actuator 24Vac/dc Modulating 0-10vdc SR24A S4 20 Nm Actuator 24Vac/dc 3 Point for up to 50mm Valves LRF24-SR S2 5 Nm Actuator 24Vac/dc Modulating 0-10vdc T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 NRF24-SZ S3 10 Nm Actuator 24Vac/dc Modulating 0-10vdc E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Belimo Butterfly valves and Rotary Actuators Description Technical Specification Belimo Wafer type butterly valves for shut-off functions in open and closed cold and hot water Systems. The butterly valve is opened or closed completely by an open-close rotary actuator. Continuous rotary actuators are can move the valve discs into any position desired. The disc made of stainless steel is pressed into the soft-sealing EPDM seat. Part Code Description D625N 25mm Butterfly Valve Wafer Type PN 16 F05 D632N 32mm Butterfly Valve Wafer Type PN 16 F05 D640N 40mm Butterfly Valve Wafer Type PN 16 F05 D650N 50mm Butterfly Valve Wafer Type PN 16 F05 D665N 65mm Butterfly Valve Wafer Type PN 16 F05 D680N 80mm Butterfly Valve Wafer Type PN 16 F05 D6100N 100mm Butterfly Valve Wafer Type PN 16 F05 D6125N 125mm Butterfly Valve Wafer Type PN 16 F07 D6150N 150mm Butterfly Valve Wafer Type PN 16 F07 Media: Cold and warm water with max 50% volume of glycol Media temperature:–20°C ... +120°C Rated pressure: ps 1600 kPa Leakage rate: A, tight (EN 12266-1) Angle of rotation:90° Installation position:Vertical to horizontal (in relation to the stem) Maintenance:Maintenance-free Fitting: EN-JS1030 (GGG 40), Disc: DIN/EN 1.4301 / AISI SS 304 (Stainless steel) Stem: DIN/EN 1.4005 / AISI SS 416 (Stainless steel) Seat:EPDM Stem seal: EPDM O-ring Stem bearing:RPTFE Butterfly valves E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Note: sizes available up to 700mm, contact sales office. Suitable Belimo Actuators for above valves: Part Code Description SR24A-5 20Nm Actuator 24Vac/dc open/close and 3 Point GR24A-5 40Nm Actuator 24Vac/dc open/close only GR24A-7 40Nm Actuator 24Vac/dc open/close only DGR24A-7 60Nm Actuator 24Vac/dc open/close only SR230A-5 20Nm Actuator 230Vac open/close and 3 Point GR230A-5 40Nm Actuator 230Vac open/close only GR230A-7 40Nm Actuator 230Vac open/close only DGR230A-7 60Nm Actuator 230Vac open/close only S1A End Switch 1 x SPDT to suit all above S2A End Switch 2 x SPDT to suit all above Note: -5 for F05 fitting valves. -7 for F07 fitting Valves T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 97 E.C.Products Building Management Controls & Peripherals Shoe valves E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Rotary Shoe Valves VR-S/F Description Technical Specification ESBE 3 port rotary shoe valves Part Code Description VR-S20 20mm 3 port screwed rotary shoe valve VR-S25 25mm 3 port screwed rotary shoe valve VR-S32 32mm 3 port screwed rotary shoe valve VR-S40 40mm 3 port screwed rotary shoe valve VR-S50 50mm 3 port screwed rotary shoe valve MS-NRE6 Linkage kit HT actuators to Esbe valves HT24-3 24V open/close motor HT230-3 230V open/close motor HT24-SR 24V 0..10Vdc open/close motor VR-F65 65mm 3 port flanged rotary shoe valve VR-F80 80mm 3 port flanged rotary shoe valve VR-F100 100mm 3 port flanged rotary shoe valve VR-F125 125mm 3 port flanged rotary shoe valve VR-F150 150mm 3 port flanged rotary shoe valve SM-VRL Linkage kit for SM...Actuators to ESBE 65mm upwards SM24-A 24V open/close motor SM24A-SR 24V 0..10Vdc open/close motor SM230-A 230V open/close motor Material: Cast Iron Operating Pressure Pmax: 6 Bar Max. Differential Pressure: Mixing - 0.1 Bar, Diverting - 0.3 Bar Leakage Rate:<1% Water Temperature: +2/+100ºc SM230A-SR 24V 0..10Vdc open/close motor ESBE Rotary Shoe Valve Actuator ARA600 Description Part Code The ESBE series VR-ARA600 and VR-9 are a compact actuator designed for operating rotary mixing valves. The actuators are controlled by 3-point and Modulating signal, and are recommended for mixing applications. The actuators have an operating range of 90° and the valves can easily be manually operated by the pull and turn knob on the front of the actuator. 98 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Description VR-ARA664 24Vac Open/Close Esbe Actuator 20mm-50mm VR-ARA652 230Vac Open/Close Esbe Actuator 20mm-50mm VR-ARA659 24Vac 0-10Vdc Modulating Esbe Actuator 20mm-50mm VR-92M 24Vac Open/Close Esbe Actuator c/w Switches 65mm-150mm VR-95M 230Vac Open/Close Esbe Actuator c/w Switches 65mm-150mm VR-92P 24Vac 0-10Vdc Modulating Esbe Actuator 65mm-150mm E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Servo operated valves SV Description Technical Specification A range of brass solenoid for air, gas and water complete with coil and connector Features •Available normally closed or normally open •Brass body and cover •Stainless steel inner construction •Optional seal materials •Response time 16/18 milliseconds •Operating range -10°C to +50°C Body: OT58 Brass Internals: Stainless steel Shading ring:Copper Electrical parts: See coil chart Seal materials: NBR, Viton® or EPDM Media: Air, Gas, Water [hot & cold] Oil, non-corrosive fluids Ambient temperature:–10°C to +50°C Response time: 16/18 milliseconds Mounting: Horizontal preferred Coil Voltages: 12, 24, 110, 230V Part Code Description Part Code Description SV15/NC/24 ½” Solenoid Valve 24Vac Normally Closed SV32/NC/24 1¼” Solenoid Valve 24Vac Normally Closed SV15/NO/24 ½” Solenoid Valve 24Vac Normally Open SV32/NO/24 1¼” Solenoid Valve 24Vac Normally Open SV15/NC/230 ½” Solenoid Valve 230Vac Normally Closed SV32/NC/230 1¼” Solenoid Valve 230Vac Normally Closed SV15/NO/230 ½” Solenoid Valve 230Vac Normally Open Solenoid valves E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH SV32/NO/230 1¼” Solenoid Valve 230Vac Normally Open SV20/NC/24 ¾” Solenoid Valve 24Vac Normally Closed SV40/NC/24 1½” Solenoid Valve 24Vac Normally Closed SV20/NO/24 ¾” Solenoid Valve 24Vac Normally Open SV40/NO/24 1½” Solenoid Valve 24Vac Normally Open SV20/NC/230 ¾” Solenoid Valve 230Vac Normally Closed SV40/NC/230 1½” Solenoid Valve 230Vac Normally Closed SV20/NO/230 ¾” Solenoid Valve 230Vac Normally Open SV40/NO/230 1½” Solenoid Valve 230Vac Normally Open SV25/NC/24 1” Solenoid Valve 24Vac Normally Closed SV50/NC/24 2” Solenoid Valve 24Vac Normally Closed SV25/NO/24 1” Solenoid Valve 24Vac Normally Open SV50/NO/24 2” Solenoid Valve 24Vac Normally Open SV25/NC/230 1” Solenoid Valve 230Vac Normally Closed SV50/NC/230 2” Solenoid Valve 230Vac Normally Closed SV25/NO/230 1” Solenoid Valve 230Vac Normally Open SV50/NO/230 2” Solenoid Valve 230Vac Normally Open Supplied as standard with NBR seals, for information on other seals contact our sales office Servo operated valves SV and L182 Part Code Description L182D01-1-230 Solenoid Valve 1" N/C 230Vac L182D01-1-24 Solenoid Valve 1" N/C 24Vac L182D01-3/4-230 Solenoid Valve 3/4" N/C 230Vac L182D01-3/4-24 Solenoid Valve 3/4" N/C 24Vac L182D01-1/2-230 Solenoid Valve 1/2" N/C 230Vac L182D01-1/2-24 Solenoid Valve 1/2" N/C 24Vac L182 Din Cap Din Cap Required for above T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 99 E.C.Products Building Management Controls & Peripherals Zone valves E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Spring Return Zone Valves DB-VZx-xx Description Technical Specification On-off control of hot or cold water flow. The valves DB-VZ coupled with synchronous motor SM230/SM24/CA and SM230/SA, SM24/SA are suitable for heating and cooling water in zone systems for ON-OFF control. The synchronous motor opens the valve (normally closed) Typical applications are for fan-coil units. Power ON drives the motor, power OFF and the Valve Spring Returns 2-way valves: the plug closes against the flow; 3-way valves: the plug blocks the flow toward user side. Features •Detachable actuator •Optional auxillary switches •BSP thread •Rugged construction 100 Part Code Description DB-VZ2-15 2 Port Valve 1/2” BSP Thread DB-VZ2-20 2 Port Valve 3/4” BSP Thread DB-VZ2-25 2 Port Valve 1” BSP Thread DB-VZ3-15 3 Port Valve 1/2” BSP Thread DB-VZ3-20 3 Port Valve 3/4” BSP Thread DB-VZ3-25 3 Port Valve 1” BSP Thread SM230/CA Actuator 230Vac with Aux Switch SM24/CA Actuator 24Vac with Aux Switch T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Synchronous motor Power supply: Max electrical load: Power consumption: Working temp.: Working humidy: Material: Protection: Dimensions: Weight: 230 or 24 Vac 3 A, 125...250 Vac 7 vA +0...+60 ºC 10...90% r.h. Plate: casting aluminium alloyed Cover: fire-proof ABS IP20, class II See Data Sheet See Data Sheet Valve Valve type: 2 or 3 ways Fluid temp.: +2...+94 ºC Material: Valve body: forged brass Valve rod: stainless steel Aisi 302 Seal material:NBR Storage temp.: –20...+70 ºC <95% r.h. Dimensions: See Data Sheet Weight: See Data Sheet E: sales@ecproducts.co.uk W: www.ecproducts.co.uk E.C.Products Building Management Controls & Peripherals Water Leak Detection WL Description Technical Specification The WLM4 Leak detection module has 4 inputs with zone indication and 1 common output with fault indication. Din rail or wall mount options. The WLM can be used with a combination of sensors. Features •Din rail or Wall mounting •Status LED indication •Selectable built in sounder and mute •24Vac/dc or 230Vac supply •Compact enclosed design Part Code Description WLM4-24 24 Volt 4 Zone Leak Detection Modules WLM4-230 230 Volt 4 Zone Leak Detection Modules CA-XSA-4W Wall Mount Case WL-RS1 Rain Sensor with Integral Heater WL-PS1 Point Sensor WL-CS5 5 Meter Cable sensor WL-CS10 10 Meter Cable sensor WL-CS15 15 Meter Cable sensor T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Output: 10Amp @230Vac Volt Free change over contact Supply Voltage: 24Vac/dc +/- 10% or 230Vac 60mA Max sensor length: 200 Meters LED Indication: See description under LED Status Termination: Rising Clamp for 0.5 to 2.5mm² Cable Ambient: –10 to +40°C Dimensions:Module: 70 x 60 x 90 mm Wall Mount case: 110 x 90 x 200 mm E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Water leak E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 101 E.C.Products Building Management Controls & Peripherals Condensation sensors E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Condensation Sensor KW Description Technical Specification The condensation control switch is installed on cooling or cold water piping or on cooled surfaces to detect generation of dew. Monitoring cooling ceilings or pipes, it can be operated so that the switching output is activated when dew is generating on cooling ceilings or the object to be monitored, thus starting a heating system or other actuators. Features •Supplied with fixing strap •IP65 Protection •Selectable NC/NO Contact output •Adjustable sensitivity Part Code Description KW-O/S Condensation Detector Power supply:24Vac/dc Switching threshold: ca. 95 % RH., variation of ca. ± 5 % RH Output signal: 24V NO/NC contact selectable by jumper Process connection: metal strap for pipes up to 3“ diameter Electrical connection: 0.14 - 1.5 mm² via terminal screws Enclosure: Material polyamide,colour pure white Dimensions: 72 x 64 x 39.4 mm Cable union: M16, including strain relief Protection type: IP 65 Condensation Sensor CBS Description Technical Specification Low cost self contained sensors for detecting the onset of condensation. The units are available in normally open or normally closed versions providing volt-free contact or current outputs. These units are installed on the surface requiring monitoring. Features •Detect onset of condensation •Suitable for chilled beam airconditioning systems •Volt free or current output •Normally open or normally closed versions •Easily installed using cable tie or metal strap supplied •24V AC or DC powered 102 Part Code Description CBS1-NO Condensation Detector NO contact CBS1-NC Condensation Detector NC contact T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Operating characteristics Output signals, NO: 2-wire mode dry < 5mA wet >10mA 4-wire mode dry Open cct wet 1KW Output signals, NC: 2-wire mode dry >10mA wet <5mA 4-wire mode dry 1KW wet Open cct In 4-wire mode, output is isolated from supply Operating conditions: 0 to +40°C Electrical specifications Supply voltage: 15-30VDC or 21VAC Maximum supply voltage:40VDC or 27VAC Max operating current: 14mA DC Connections: Flying lead Mechanical details Dimensions: 90 x 45 x 32mm Weight:140g E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Multifunction Timer TM-MFT Description Technical Specification Single channel panel mount timer for digital control. Fully programmable for daily or weekly cycles supplied with battery backup by means of a Lithium button cell. Features •17.5mm Wide •7 Time Scales from 1 Second to 100 hours •Multi Function: 7 Functions •Multi Voltage: 12-240 VAC/DC •35mm Din Rail Mount •8A 250VAC Contact Rating •CE & UL Approved Part Code Description TM-MFT Single Channel Panel Mount Timer Operating Voltage: 12-240VAC/DC (+/-10%) Power Consumption: 1.9VA (Approx.) Ambient Humidity: Max 85% RH Reset Time: 0.5 Seconds Ambient Temperature: –10 to +50ºC Rated Frequency: 50/ 60 Hz Mechanical Endurance: 5,000,000 Ops Contact Rating: 8A 250VAC Electrical Endurance: 100,000 Ops Weight:62g Timers E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Plant Extension Timer EP-PET4 Description Technical Specification The EP-PET4 Extension timer is a high output electronic timer which provides control for a wide range of loads. The unit allows an appliance to be powered for a set time period which can be adjusted by the user. A simple LED display shows the user how much time is left to run. Pressing the switch whilst the unit is operating allows the user to cancel timing program, and the memory function of the timer will remember the last time period selected. Features •Duel supply •1–4 hour timing period •Flush or surface mount Part Code Description EP-PET4 Plant Extension Timer T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Load: 16 Amp resistive load (inc. immersion heaters) 6 Amp fluorescent lighting 3 Amp compact fluorescent lighting 3 Amp low energy lighting 3 Amp low voltage lighting (switch primary of transformer) Fluorescent lighting (max 6 fittings recommended) Supply Voltage: 220-240 Volts AC 50 Hz 24VAC/DC +/- 10% Time Out Period: 1, 2, 3 or 4 hours (selectable) Terminal Capacity:4.0mm2 Material: Flame retardant ABS Class 2 Temperature: –10°C to 35°C Conformity:EMC-89/336/EEC LVD-73/23/EEC E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 103 E.C.Products Building Management Controls & Peripherals Timers E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Plant Extension Timer EP-LAP Description Technical Specification The EP-LAP electronic timer switch provides energy saving functionality in ventilation, boiler and lighting installations. It is ideal for applications where simple interface is required to control the extension times of the plant. Other typical applications include manual override to provide intensive ventilation during busy periods. Power Supply: Relay Contact: Time Selection: Accuracy: Housing: 24Vac or 230Vac 10A @ 230Vac EP-LAP5 - 1...5 hours EP-LAP10 - 2...10 hours <± 1 s/h White Plastic IP20 85 x 85 x 46 Features •5 or 10 hour versions •Flush or surface mounted •24Vac or 230Vac Power Supply •Timer Hold Feature Part Code Description EP-LAP5 Plant Extension Timer 5 hours EP-LAP10 Plant Extension Timer 10 hours Panel and Surface Mount Digital Timers TM6xxx Description Technical Specification Single channel panel mount timer for digital control. Fully programmable for daily or weekly cycles supplied with battery backup by means of a Lithium button cell. Features Contact: 16A @230Vac SPCO Power Consumption:7VA Ambient Operating Temp:–10 to 55°C Programming Resolution: 1 Minute. Clock Accuracy: <1 sec per day •4 ON/OFF periods daily •Override period button •Smallest clock adjustment 1 minute •7 day, 5+2 day or individual daily setting •LED indication •ON-OFF-AUTO Selection 104 Part Code Description TM6192 Single Channel Panel Mount Timer TM6331 Single Channel Surface Mount Timer T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Din Rail Digital Timers TM8xx Description Technical Specification Single/two channel din rail mount timers for digital control. Fully programmable for daily or weekly cycles supplied with battery backup by means of a Lithium button cell. Contact: (2x) 12A @230Vac SPCO Power Consumption:7VA Ambient Operating Temp:–10 to 55°C Programming Resolution: 1 Minute. Clock Accuracy: <1 sec per day Features Timers E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH •4 ON/OFF periods daily per channel •Override period button •Smallest clock adjustment 1 minute •7 day, 5+2 day or individual daily setting per channel •LED indication •ON-OFF-AUTO Selection Part Code Description TM848 Single Channel Din Rail Timer TM812 Two Channel Din Rail Timer Panel Ventilation FA Description The FA range of panel ventilation products include high quality Fans Grills and Finger Guards for Panel Manufacturers. Part Code Description W x H x D FA-F120-230 Axial Fan 230Vac 165M³/Hr 120 x 120 x 38mm FA-F120-24 Axial Fan 24Vac 150M³/Hr 120 x 120 x 38mm FA-FK150-230 Combined Fan And Filter Unit, Fan 120 x 120 x 38mm FA-CFG120 Chrome finger guard to fit 120mm Axial Fan FA-PFG120 Plastic Finger Guard to fit 120mm Axial Fan FA-TS-NO Din Rail Mounted Thermostat 10Amp @230Vac FA-FFG-120 Axial Fan Filter Guard 120mm FA-FFA-120-IP54 Axial Fan Filter Guard 120mm IP54 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 105 E.C.Products Building Management Controls & Peripherals Enclosures E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Hinged Door Enclosures ENC-DED Description Technical Specification Hinged Door Enclosures are made from ABS HB material to IP65 standard and come complete with a steel back plate, mounting wall brackets and lockable key. They come in eight sizes and can be used in various environments including coastal conditions, dry dusty environments and in heavy humidity. Features •Designed to meet protection and combustible standards IP65 and IK08 •Available in eight sizes •Supplied in grey (RAL 7035) with solid door and base unit •Come complete with steel back plate, mounting brackets & key •Wall thickness on the range is 3 – 3.5mm •Made from UL approved ABS-HB flame retardant plastic •Comply with the following standards: EN 60439-1, EN 62208, CEI 23-48, CEI 23-49 •Perform within a temperature range of –20° to +85°C •Suitable for use in sea salt air conditions and dry dust environments Part Code Operating Voltage: 12-240VAC/DC (+/-10%) Power Consumption: 1.9VA (Approx.) Ambient Humidity: Max 85% RH Reset Time: 0.5 Seconds Ambient Temperature: –10 to +50ºC Rated Frequency: 50/ 60 Hz Mechanical Endurance: 5,000,000 Ops Contact Rating: 8A 250VAC Electrical Endurance: 100,000 Ops Weight:62g Description W x H x D ENC-DED001 200x300x130mm Enclosure with hinged door ENC-DED002 250x350x150mm Enclosure with hinged door ENC-DED004 300x400x170mm Enclosure with hinged door ENC-DED005 300x400x220mm Enclosure with hinged door ENC-DED006 350x500x190mm Enclosure with hinged door ENC-DED007 400x500x240mm Enclosure with hinged door ENC-DED008 400x600x200mm Enclosure with hinged door ENC-DED010 500x700x250mm Enclosure with hinged door 106 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Bespoke Bespoke products and user interfaces Upon request special sensors and interfaces are available. Engraved plates with set points, push buttons, displays and sensors. Available in a variety of finishes including brass, stainless steel and plastic as well as any other electroplated finish. Please contact our sales office for more information and quotations. T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 107 E.C.Products Building Management Controls & Peripherals Contactors E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH AC Contactors CC1-Dx Description Coil Voltages The CC1-D Series AC Contactors are suitable for use in circuits up to the rated voltage of 660Vac 50/60Hz and are suited to applications such as making, breaking, frequently starting and controlling AC motors. A range of accessories are available The units are manufactured to IEC60947-4 and certified SEMKO. To order these items, please specify coil voltage and contact type. Example: CC1-D09/B5/NO = 4Kw contactor, 24Vac coil, normally open contact Features Coil Voltages (VAC) 24 230 50Hz B5 P5 50/60Hz B7 P7 •Choice of coil voltages •Up to 95A rated current •Accessories available Rated Current (A) Power Rating of 3-ph motors AC3 (Kw) Part Code AC3 AC4 220/230V 380/400V 415V Rated Heat Electrical Life Mech. Life x106 No. of contacts Current (A) lth AC3 x106 CC1-D09 9 3.5 2.2 4 4 20 2 20 3P + NO/ 3P + NC CC1-D12 12 5 3 5.5 5.5 20 2 20 3P + NO/ 3P + NC CC1-D18 18 7.7 4 7.5 9 32 2 20 3P + NO/ 3P + NC CC1-D25 25 8.5 5.5 11 11 40 2 20 3P + NO/ 3P + NC CC1-D32 32 12 7.5 15 15 50 2 20 3P + NO/ 3P + NC CC1-D40 40 18.5 11 18.5 22 60 2 20 3P + NO + NC CC1-D50 50 24 15 22 25 80 2 20 3P + NO + NC CC1-D65 65 28 18.5 30 37 80 1.6 20 3P + NO + NC CC1-D80 80 37 22 37 45 125 1.6 10 3P + NO + NC CC1-D95 95 44 25 45 45 125 1.6 10 3P + NO + NC AC Contactors Accessories 108 Part Code Description CA1-DN11 Top Auxiliary Contact Block 1NO + 1NC for CC1-D CA1-DN22 Top Auxiliary Contact Block 2NO + 2NC for CC1-D CA1-DN40 Top Auxiliary Contact Block 4NO for CC1-D CA1-DN04 Top Auxiliary Contact Block 4NC for CC1-D CX1-D2 Spare Coils for CC1-D09, D12, D18 (specify voltage eg. CX1-D2/B5) CX1-D4 Spare Coils for CC1-D25, D32 (specify voltage eg. CX1-D2/B5) CX1-D6 Spare Coils for CC1-D40 - D95(specify voltage eg. CX1-D2/B5) CA9-D09-32 Mechanical Interlocks for CC1-D09 to CC1-D32 CA9-D40-95 Mechanical Interlocks for CC1-D40 to CC1-D95 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH E.C.Products Building Management Controls & Peripherals Description Features CR2-D/K thermal overload relays are designed to protect AC circuits and motors against overload, phase failure and prolonged starting of the motor. Part Code Overloads Thermal Overload Relays CR2-x •Test Button •Stop Button •Reset Button •Trip Indicator Range CR2-D1301 0.10-0.16A CR2-D1302 0.16-0.25A CR2-D1303 0.25-0.40A CR2-D1304 0.40-0.63A CR2-D1305 0.63-1.0A CR2-D1306 1.0-1.6A CR2-D1307 1.6-2.5A CR2-D1308 2.5-4.0A CR2-D1310 4.0-6.0A CR2-D1312 5.5-8.0A CR2-D1314 7.0-10.0A CR2-D1316 9.0-13.0A CR2-D1321 12.0-18.0A CR2-D1322 17.0-25.0A CR2-D3353 23.0-32.0A CR2-D3355 30.0-40.0A CR2-D3357 37.0-50.0A CR2-D3359 48.0-65.0A CR2-D3361 55.0-70.0A CR2-D3363 63.0-80.0A CR2-D3365 80.0-93.0A T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 109 E.C.Products Building Management Controls & Peripherals Moror starters E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Manual Motor Starters CAV2 Description Features The CAV2 series motor protection circuit breakers are mainly used for overload and short circuit protection of AC motors, as a full voltage starter to start and stop the motor or for the overload and short circuit protection of the circuit and power equipment. •Wide choice of current ranges •Auxiliary switch available Standard Kw Power Ratings of 3-phase motors 50/60Hz in category AC-3 110 220V 380V 415V 440V 500V 660V Setting Range Motor Protection Circuit breaker (Manual Motor Starter) 0.25-0.4A – – – – – – 0.25...4 CAV2-M04 Motor Protection Circuit breaker (Manual Motor Starter) 0.4-0.63A – – – – – 0.37 0.4...0.63 CAV2-M05 Motor Protection Circuit breaker (Manual Motor Starter) 0.63-1.0A – – – 0.37 0.37 0.55 0.63...1 CAV2-M06 Motor Protection Circuit breaker (Manual Motor Starter) 1-1.6A – 0.37 – 0.55 0.75 1.1 1...1.6 CAV2-M07 Motor Protection Circuit breaker (Manual Motor Starter) 1.6-2.5A 0.37 0.75 0.75 1.1 1.1 1.5 1.6-2.5 CAV2-M08 Motor Protection Circuit breaker (Manual Motor Starter) 2.5-4A 0.75 1.5 1.5 1.5 2.2 3 2.5...4 CAV2-M10 Motor Protection Circuit breaker (Manual Motor Starter) 4-6.3A 1.1 2.2 2.2 3 3.7 4 4...6.3 CAV2-M14 Motor Protection Circuit breaker (Manual Motor Starter) 6-10A 2.2 4 4 4 5.5 7.5 6...10 CAV2-M16 Motor Protection Circuit breaker (Manual Motor Starter) 9-14A 3 5.5 5.5 7.5 7.5 9 9...14 CAV2-M20 Motor Protection Circuit breaker (Manual Motor Starter) 13-18A 4 7.5 9 9 9 11 13...18 CAV2-M21 Motor Protection Circuit breaker (Manual Motor Starter) 17-23A 5.5 11 11 11 11 15 17...23 CAV2-M22 Motor Protection Circuit breaker (Manual Motor Starter) 20-25A 5.5 11 11 11 15 18.5 20...25 CAV2-M32 Motor Protection Circuit breaker (Manual Motor Starter) 24-32A 7.5 15 15 15 18.5 26 24...32 CAV2-AN11 Auxiliary Contact Block for CAV2-M Part Code Description CAV2-M03 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Boxed Isolators LW30 Description Features The LW30 are a range of boxed isolators in a choice of current ratings and housed inside an IP65 enclosure Part Code Description LW30-20-400011 4 Pole Boxed Switch Disconnector 20A LW30-32-400011 4 Pole Boxed Switch Disconnector 32A LW30-40-400011 4 Pole Boxed Switch Disconnector 40A LW30-63-400011 4 Pole Boxed Switch Disconnector 63A LW30-80-400011 4 Pole Boxed Switch Disconnector 80A •Choice of current ratings •IP65 enclosure Isolators E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH LW30-100-400011 4 Pole Boxed Switch Disconnector 100A Door Interlocked Isolators LW30 Description Features The LW30 are a range of door isolators in a choice of current ratings and are supplied with a 300mm long shaft. •Choice of current ratings •300mm shaft Part Code Description LW30-20-400040 4 Pole Door Interlocked Switch Disconnector 20A LW30-32-400040 4 Pole Door Interlocked Switch Disconnector 32A LW30-63-400040 4 Pole Door Interlocked Switch Disconnector 63A LW30-80-400040 4 Pole Door Interlocked Switch Disconnector 80A LW30-100-400040 4 Pole Door Interlocked Switch Disconnector 100A Description Features A range of enclosures suitable for housing circuit breakers available as flush or wall mounting and supplied complete with DIN rail and earth connecting strips. •Up to 36 ways •Flush or wall mounted Flush Wall Description CA-XSA-4F CA-XSA-4W Distribution Enclosure Flush or Wall Mount 4 way CA-XSA-6F CA-XSA-6W Distribution Enclosure Flush or Wall Mount 6 way CA-XSA-8F CA-XSA-8W Distribution Enclosure Flush or Wall Mount 8 way CA-XSA-12F CA-XSA-12W Distribution Enclosure Flush or Wall Mount 12 way CA-XSA-18F CA-XSA-18W Distribution Enclosure Flush or Wall Mount 18 way CA-XSA-24F CA-XSA-24W Distribution Enclosure Flush or Wall Mount 24 way CA-XSA-36F CA-XSA-36W Distribution Enclosure Flush or Wall Mount 36 way T: +44 (0)20 8569 4100 MCB enclosures Distribution Enclosures CA-XSA-x F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 111 E.C.Products Building Management Controls & Peripherals RCCB Mains switch isolators E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Mainswitch Isolators CAH1 Description Technical Specification A range of items suitable to provide isolation functions and to be used as a main switch. Features •Provides function of isolation •Contact position indication Part Code Description CAH1-100/1P40 Single Pole Isolator/Mainswitch 40A CAH1-100/1P63 Single Pole Isolator/Mainswitch 63A CAH1-100/1P80 Single Pole Isolator/Mainswitch 80A CAH1-100/1P100 Single Pole Isolator/Mainswitch 100A Residual Current Circuit Breakers CAL2 Description Technical Specification A range of Residual Current Circuit Breakers to provide protection against earth fault/leakage current. Features •Contact position Indication •Finger protected terminals 112 Number of Poles: 1 or 2 Rated Current: See below Rated Voltage: 230Vac 50/60Hz Rated Short-circuit capacity:6kA Maximmum Current: 1500A for 1 second Electro-Mechanical Endurance: 10000 cycles Mounting: DIN rail Number of Poles: 2/4 poles Rated making/breaking capacity:630A Rated Current: See below Rated Voltage: 230/400Vac, 50/60Hz Rated Residual Operating Current:30mA Conditional Short Circuit Current:6kA Tripping Duration: <0.1 s Electro-Mechanical Endurance: 4000 cycles Mounting: DIN rail Part Code Description CAL2-25I/2P30 Two Pole Residual Current Circuit Breaker 25A 30mA trip CAL2-40I/2P30 Two Pole Residual Current Circuit Breaker 40A 30mA trip CAL2-63I/2P30 Two Pole Residual Current Circuit Breaker 63A 30mA trip T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk RCCB with Overcurrent Protection CA30LE Description Technical Specification Rated Voltage: 230/240Vac, 50/60Hz Short Circuit Capacity:3kA Rated Current: See below Rated Residual Operating Current:30mA Poles: 1P + n Tripping Curves: B, C Mounting: DIN rail Features •Contact position Indication •DIN ail mounted Curve B Curve C Description CA30LE-6B CA30LE-6C Two Pole (1P + N) RCBO 6A Curve B or C 30mA trip CA30LE-16B CA30LE-16C Two Pole (1P + N) RCBO 16A Curve B or C 30mA trip CA30LE-20B CA30LE-20C Two Pole (1P + N) RCBO 20A Curve B or C 30mA trip CA30LE-32B CA30LE-32C Two Pole (1P + N) RCBO 32A Curve B or C 30mA trip Miniature Circuit Breakers DZ47 Description Technical Specification A range of miniature circuit breakers suitable 230/400Vac, 50/60Hz rated circuits up to 63 amps. They provide protection against overload and short circuits in electrical circuits and equipment in household and commercial applications. They can also be used for non-frequent changeover of electrical circuits. Features •Protection against overload and short circuit •Contact position indication •DIN rail mounted Number of Poles: 1P, 2P or 3P Rated Voltage:230/400Vac Rated Current: 1, 2, 4, 6, 10, 12, 16, 20, 25, 32, 40, 50, 63 amps Tripping Curve: B, C or D Rated Short Circuit Capacity:6kA Rated Frequency:50/60Hz Energy Limiting Class:3 Rated Impulse Voltage withstand:6.2kV Electro-Mechanical Endurance: 4000 cycles Connection Terminal: Pillar Terminal with clamp Connection Capacity: Rigid conductor up to 25mm² Mounting: DIN rail Curve B Curve C Curve D Description DZ47-63/1PxB DZ47-63/1PxC DZ47-63/1PxD Single pole Miniature Circuit Breaker x= current rating see above – DZ47-63/2PxC – – DZ47-63/3PxC DZ47-63/3PxD T: +44 (0)20 8569 4100 MCB A range of RCBO units to provide protection against earth fault/leakage current and overload. RCBO E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Two pole Miniature Circuit Breaker x= current rating see above Three pole Miniature Circuit Breaker x= current rating see above F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 113 Push Buttons E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH E.C.Products Building Management Controls & Peripherals Pushbutton Switches XB2-xA Description XB2 series pushbuttons are used in the control of electrical circuits. A choice of panel mounting bezel and colours is available as well as different combinations of contact block. Illuminated versions can also be supplied. Features •Choice of colours •Choice of bezel Technical Specification Rated Insulation Voltage:660V Operating Temperature:–5…+40°c Operating Humidity: 45...85% RH Electrical Life: 50 x 10°C operations Protection:IP40 Part Code Description XB2-BA11 Normally open pushbutton white - metal bezel XB2-BA21 Normally open pushbutton black - metal bezel XB2-BA31 Normally open pushbutton green - metal bezel XB2-BA42 Normally closed pushbutton red - metal bezel XB2-BA51 Normally open pushbutton yellow - metal bezel XB2-BA61 Normally open pushbutton blue - metal bezel XB2-EA11 Normally open pushbutton white - plastic bezel XB2-EA21 Normally open pushbutton black - plastic bezel XB2-EA31 Normally open pushbutton green - plastic bezel XB2-EA42 Normally closed pushbutton red - plastic bezel XB2-EA51 Normally open pushbutton yellow - plastic bezel XB2-EA61 Normally open pushbutton blue - plastic bezel ZB2-BE101 N/O Contact ZB2-BE102 N/C Contact Part Code Description XB2-BP21 Normally open pushbutton black - IP66 XB2-BP31 Normally open pushbutton green - IP66 XB2-BP42 Normally closed pushbutton red - IP66 XB2-BP51 Normally open pushbutton yellow - IP66 XB2-BP61 Normally open pushbutton blue - IP66 ZB2-BE101 N/O Contact ZB2-BE102 N/C Contact Pushbutton Switches IP66 XB2-BP Description XB2-BP series pushbuttons are used in the control of electrical circuits. A choice of colours is available and the units are supplied with a waterproof boot giving IP66 protection. Features •Choice of colours •IP66 Protection Technical Specification Rated Insulation Voltage:660V Operating Temperature:–5…+40°c Operating Humidity: 45...85% RH Electrical Life: 50 x 105 operations Protection:IP66 114 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Illuminated Pushbuttons XB2-xW Description Technical Specification XB2 series illuminated pushbuttons are used in the control of electrical circuits. A choice of panel mounting bezel and colours is available as well as different combinations of contact block. Illuminated versions use LEDs for long life. Features Rated Insulation Voltage:660V Operating Temperature:–5…+40°c Operating Humidity: 45...85% RH Electrical Life: 50 x 105 operations Protection:IP40 Push Buttons E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH •Choice of colours •Choice of bezel •LED Illumination Part Code Description XB2-BW11 Normally open 24V LED illuminated pushbutton white - metal bezel XB2-BW31 Normally open 24V LED illuminated pushbutton green - metal bezel XB2-BW42 Normally closed 24V LED illuminated pushbutton red - metal bezel XB2-BW51 Normally open 24V LED illuminated pushbutton yellow - metal bezel XB2-BW61 Normally open 24V LED illuminated pushbutton blue - metal bezel XB2-EW11 Normally open 24V LED illuminated pushbutton white - plastic bezel XB2-EW31 Normally open 24V LED illuminated pushbutton green - plastic bezel XB2-EW42 Normally closed 24V LED illuminated pushbutton red - plastic bezel XB2-EW51 Normally open 24V LED illuminated pushbutton yellow - plastic bezel XB2-EW61 Normally open 24V LED illuminated pushbutton blue - plastic bezel ZB2-BE101 N/O Contact ZB2-BE102 N/C Contact Mushroom Head Pushbuttons XB2-BSx Description Technical Specification XB2-BS series pushbuttons are used in the control of electrical circuits. Units are supplied in a choice of 40mm diameter mushroom head with turn to release or key release mechanism. Rated Insulation Voltage:660V Operating Temperature:–5…+40°c Operating Humidity: 45...85% RH Electrical Life: 50 x 105 operations Protection:IP40 Features •40mm diameter mushroom head •Turn or key to release versions Part Code Description XB2-BS542 Mushroom head pushbutton, turn to release, normally closed XB2-BS142 Mushroom head pushbutton, key to release, normally closed XB2-ER60 60mm diameter Emergency Stop warning circle ZB2-BE101 N/O Contact ZB2-BE102 N/C Contact T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 115 E.C.Products Building Management Controls & Peripherals Selector Switches E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Selector Switches XB2-x Description Technical Specification XB2 series rotary selector switches are used in the control of electrical circuits . A choice of panel mounting bezel is available as well as long or short handles, key operated and 2/3 way versions. Illuminated versions in a choice of colours can also be supplied. Rated Insulation Voltage:660V Operating Temperature:–5…+40°c Operating Humidity: 45...85% RH Electrical Life: 50 x 10 5 operations Protection:IP40 Features •Key operated versions •Metal or plastic bezel •2 or 3 way versions •Illuminated versions Part Code Description XB2-BD21 2 position NO stay put rotary switch - metal bezel XB2-BD25 2 position NO + NC stay put rotary switch - metal bezel XB2-BD33 3 position NO + NO stay put rotary switch - metal bezel XB2-BJ21 2 position NO stay put rotary switch - metal bezel, long handle XB2-BJ25 2 position NO + NC stay put rotary switch - metal bezel, long handle XB2-BJ33 3 position NO + NO stay put rotary switch - metal bezel, long handle XB2-BG21 2 position NO stay put rotary switch - metal bezel, key operated XB2-BG25 2 position NO + NC stay put rotary switch - metal bezel, key operated XB2-BG33 3 position NO + NO stay put rotary switch - metal bezel, key operated XB2-ED21 2 position NO stay put rotary switch - plastic bezel XB2-ED25 2 position NO + NC stay put rotary switch - plastic bezel XB2-ED33 3 position NO + NO stay put rotary switch - plastic bezel XB2-EG21 2 position NO stay put rotary switch - plastic bezel, key operated XB2-EG25 2 position NO + NC stay put rotary switch - plastic bezel, key operated XB2-EG33 3 position NO + NO stay put rotary switch - plastic bezel, key operated XB2-BK21 2 position NO + NC stay put 24V LED illuminated rotary switch white - metal bezel XB2-BK23 2 position NO + NC stay put 24V LED illuminated rotary switch green - metal bezel XB2-BK24 2 position NO + NC stay put 24V LED illuminated rotary switch red - metal bezel XB2-BK25 2 position NO + NC stay put 24V LED illuminated rotary switch yellow - metal bezel XB2-BK26 2 position NO + NC stay put 24V LED illuminated rotary switch blue - metal bezel XB2-BK31 3 position NO + NC stay put 24V LED illuminated rotary switch white - metal bezel XB2-BK33 3 position NO + NC stay put 24V LED illuminated rotary switch green - metal bezel XB2-BK34 3 position NO + NC stay put 24V LED illuminated rotary switch red - metal bezel XB2-BK35 3 position NO + NC stay put 24V LED illuminated rotary switch yellow - metal bezel XB2-BK36 3 position NO + NC stay put 24V LED illuminated rotary switch blue - metal bezel ZB2-BE101 N/O Contact ZB2-BE102 N/C Contact 116 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 16mm Panel Indicators AD16DS Description Technical Specification A range of 16/22mm indicator lamps used in electrical circuits in a variety of voltages. They are primarily used for indication and alarm signals and conform to IEC60947-5-1. The AD16DS utilize LEDs for long life and very low energy consumption and have concealed terminals. Features •Choice of colours •Choice of voltages •LED for long life 16mm 22mm 24Vac/dc 110Vac AD16DS-R AD56DS-R –24 AD16DS-G AD56DS-G AD16DS-B Operating Temperature:–5…+40° Operating Humidity: 45...85% RH Pollution Degree:3 Installation Degree:III Degree of Protection:IP65 Rated Operating Current: ≤ 80mA Electrical Life: ≥30000 hours Brightness:≥60 Rated Operating Voltage: See below Base Colour: See below 230Vac Description –110 –220 Multi LED 16/22mm panel indicator pure colour red –24 –110 –220 Multi LED 16/22mm panel indicator pure colour green AD56DS-B –24 –110 –220 Multi LED 16/22mm panel indicator pure colour blue AD16DS-Y AD56DS-Y –24 –110 –220 Multi LED 16/22mm panel indicator pure colour yellow AD16DS-W AD56DS-W –24 –110 –220 Multi LED 16/22mm panel indicator pure colour white Panel lamps E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 22mm Panel Indicators AD56HS Description Technical Specification A range of 22mm indicator lamps used in electrical circuits in a variety of voltages. They are primarily used for indication and alarm signals and conform to IEC60947-5-1. The AD56HS utilize LEDs for long life and very low energy consumption and have concealed terminals. Features •Choice of colours •Choice of voltages •LED for long life •Conical Bezel Part Code 24Vac/dc 110Vac Operating Temperature:–5…+40° Operating Humidity: 45...85% RH Pollution Degree:3 Installation Degree:III Degree of Protection:IP65 Rated Operating Current:≤ 80mA Electrical Life: ≥30000 hours Brightness:≥60 Rated Operating Voltage:See below Base Colour See below 230Vac Description AD56HS-R –24 –110 –220 Multi LED conical 22mm panel indicator pure colour red AD56HS-G –24 –110 –220 Multi LED conical 22mm panel indicator pure colour green AD56HS-B –24 –110 –220 Multi LED conical 22mm panel indicator pure colour blue AD56HS-Y –24 –110 –220 Multi LED conical 22mm panel indicator pure colour yellow AD56HS-W –24 –110 –220 Multi LED conical 22mm panel indicator pure colour white T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 117 E.C.Products Building Management Controls & Peripherals Panel lamps E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 22mm Panel Indicators with Lamp Test AD56LT Description Technical Specification A range of 22mm indicator lamps used in electrical circuits in a variety of voltages. They are primarily used for indication and alarm signals and conform to IEC60947-5-1. The AD56LT utilize LEDs for long life and very low energy consumption and have lamp test facility. Features •Choice of colours •Choice of voltages •LED for long life •Lamp Test Facility Part Code 24Vac/dc 110Vac 230Vac Description Operating Temperature:–5…+40° Operating Humidity: 45...85% RH Pollution Degree:3 Installation Degree:III Degree of Protection:IP65 Rated Operating Current: ≤ 80mA Electrical Life: ≥30000 hours Brightness:≥60 Rated Operating Voltage: See below Base Colour: See below AD56LT-R –24 –110 –220 Multi LED lamp 22mm panel indicator pure colour red AD56LT-G –24 –110 –220 Multi LED lamp 22mm panel indicator pure colour green AD56LT-B –24 –110 –220 Multi LED lamp 22mm panel indicator pure colour blue AD56LT-Y –24 –110 –220 Multi LED lamp 22mm panel indicator pure colour yellow AD56LT-W –24 –110 –220 Multi LED lamp 22mm panel indicator pure colour white 22mm Panel Indicators AD56TW Description Technical Specification A range of 22mm indicator lamps used in electrical circuits in a variety of voltages. They are primarily used for indication and alarm signals and conform to IEC60947-5-1. The AD56TW utilise LEDs for long life and very low energy consumption and have twin colours. See AD56LT above. Features •Choice of colours •Choice of voltages •LED for long life •Twin Colour Part Code AD56TW-RG 118 24Vac/dc 110Vac –24 –110 T: +44 (0)20 8569 4100 230Vac Description –220 Multi LED 22mm panel indicator colour red/green F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk E.C.Products Building Management Controls & Peripherals Xenon Beacon BX Description Technical Specification The BX Flashing Xenon Beacon is an IP65 warning Beacon available in 2 Voltages and 5 different colours which can be mounted directly or as a bayonet fitting with rear cable entry. Features Supply Voltage: 10-28 Vdc or 115-230Vac Lens colours: Red, Amber, Blue, Green or Clear Flash rate:1Hz IP Rating:IP65 Output: 1.5-2.5 Joules •Available in 5 Colours •Robust construction •Can be mounted Outside •Bayonet Mounting •2 Voltage options Part Code Description BX-R24 Red Xenon Beacon 10-28Vdc BX-A24 Amber Xenon Beacon 10-28Vdc BX-B24 Blue Xenon Beacon 10-28Vdc BX-C24 Clear Xenon Beacon 10-28Vdc BX-G24 Green Xenon Beacon 10-28Vdc BX-R230 Red Xenon Beacon 115-230Vac BX-A230 Amber Xenon Beacon 115-230Vac BX-B230 Blue Xenon Beacon 115-230Vac BX-C230 Clear Xenon Beacon 115-230Vac BX-G230 Green Xenon Beacon 115-230Vac Xenon beacons E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Spanner for 22mm Panel Indicators AD56SPAN Description A spanner suitable for tightening locking nuts on the range of 22mm panel indicators. Part Code Description AD56SPAN Spanner for 22mm Panel Indicators T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 119 E.C.Products Building Management Controls & Peripherals Cable glands E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Nylon Cable Glands Mx Description Features A range of nylon cable glands in sizes from M12 up to M50 supplied complete with locknut and most sizes in a choice of colours. •Wide size range •Choice of colours •Complete with locknut Part Code Description M12X1.5 Nylon cable gland M12 x 1.5mm c/w locknut M16X1.5 Nylon cable gland M16 x 1.5mm c/w locknut M20X1.5 Nylon cable gland M20 x 1.5mm c/w locknut - Cable size 6-12mm M20X1.5S Nylon cable gland M20 x 1.5mm c/w locknut - Cable size 4-9mm M25X1.5 Nylon cable gland M25 x 1.5mm c/w locknut M32X1.5 Nylon cable gland M32 x 1.5mm c/w locknut M40X1.5 Nylon cable gland M40 x 1.5mm c/w locknut M50X1.5 Nylon cable gland M50 x 1.5mm c/w locknut Busbar DIN Rail Available colours: R = Red, GR = Grey, BLK = Black, W = White 120 DIN Rail Description Features A range of DIN rail available in 2 metre lengths and a choice of styles. Part Code Description DIN1 35mm Slotted Din rail - 2 metre lengths DIN2 ‘G’ Profile Slotted DIN rail - 2 metre lengths DIN3 35mm Slotted Din rail deep profile - 2 metre lengths •Choice of styles •2 metre lengths Busbar PB Description Features A range of busbar available in 1 metre lengths and a choice of poles. •1, 2 or 3 pole •Pin Type Part Code Description PB1 Pin type Busbar - Single pole 63A - 1 metre lengths PB2 Pin type Busbar - Two pole 63A - 1 metre lengths PB3 Pin type Busbar - Three pole 63A - 1 metre lengths T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk DIN Rail Terminals JXB Description Features A range of DIN rail terminals with some sizes available in a choice of colours. A range of accessories is also available. Part Code Description JXB-2.5/EK DIN rail earth terminal 2.5mm² wire JXB-4/EK DIN rail earth terminal 4mm² wire JXB-6/EK DIN rail earth terminal 6mm² wire JXB-10/EK DIN rail earth terminal 10mm² wire JXB-16/EK DIN rail earth terminal 16mm² wire JXB-35/EK DIN rail earth terminal 35mm² wire JXB-EW End stop for DIN rail terminals JXB10/2.5 Connecting links for JXB-2.5 JXB10/4 Connecting links for JXB-4 JXB10/6 Connecting links for JXB-6 JBX10/10 Connecting links for JXB-10 JXB-TM Terminal marker Strips 100 pieces blank JXB-TM100 Terminal marker Strips 100 pieces 1-100 JXB-TM200 Terminal marker Strips 100 pieces 101-200 Grey Red •Top hat or ‘G’ profile DIN rail mounting Blue Description JXB-2.5/35/G JXB-2.5/35/R JXB-2.5/35/B DIN rail terminal 2.5mm² wire 24A JXB-4/35/G JXB-4/35/B DIN rail terminal 4mm² wire 32A JXB-4/35/R JXB-6/35/G – – DIN rail terminal 6mm² wire 41A JXB-10/35/G – – DIN rail terminal 10mm² wire 57A JXB-16/35/G – – DIN rail terminal 16mm² wire 76A JXB-35/35/G – – DIN rail terminal 35mm² wire 125A JXB-70/35/G – – DIN rail terminal 75mm² wire 192A JXB-EC2.5/G – JXB-EC2.5/B End Cover for JXB-2.5 JXB-EC4/G – JXB-EC4/B End cover for JXB-4, JXB-6, JXB-10 JXB-EC16/G – – End cover for JXB-16 JXB-EC35/G – – End cover for JXB-35 JXB-EC70/G – – End cover for JXB-70 JXB-RD – – DIN rail fuse terminal 6.3A JXB-KN – – DIN rail 4mm² knife disconnect terminal JXB-4/35S1 – – DIN rail double level terminal 4mm² wire T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk Terminals E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 121 E.C.Products Building Management Controls & Peripherals Terminals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 122 DIN Rail Terminals CON High quality Description Features This range of CON terminals offer a proven screw connection system for the smallest cross sections ranging from 0.08mm² to 10mm². The protective earth terminals feature a PE foot contact that is snapped on without screws, ensuring good mechanical and electrical safety. The terminals also offer an insulated pluggable jumper system allowing terminals to be easily and quickly linked. •Three colours available •Compact design •Pluggable Jumpers •4 sizes available •Secure Snap-on mounting Part Code Description Part Code Description CON-BE2.5 2.5mm Beige Terminal CON-FT Din Rail Fuse Terminal CON-BL2.5 2.5mm Blue Terminal CON-FT/EC End Cover For Fuse Terminal CON-RD2.5 2.5mm Red Terminal CON-KD Disconnect Terminal 2.5mm CON-ET2.5 2.5mm Earth Terminal CON-DDT/4 Double Deck Terminal 4.0mm CON-BE4 4.0mm Beige Terminal CON-DDT/4/EC End Cover For Double Deck Terminal CON-BL4 4.0mm Blue Terminal CON-ES End Stop CON-RD4 4.0mm Red Terminal CON-TM/B Terminal Markers Blank CON-ET4 4mm Earth Terminal CON-TM-1/50 Terminal Markers 1-50 CON-BE6 6.0mm Beige Terminal CON-TM-51/100 Terminal Markers 51-100 CON-BL6 6.0mm Blue Terminal CON-TM-101/150 Terminal Markers 101-150 CON-RD6 6.0mm Red Terminal CON-TM-151/200 Terminal Markers 151-200 CON-ET6 6mm Earth Terminal CON-TM-201/250 Terminal Markers 201-250 CON-BE10 10.0mm Beige Terminal CON-TM-251/300 Terminal Markers 251-300 CON- BL10 10.0mm Blue Terminal CON-TM-301/350 Terminal Markers 301-350 CON- RD10 10.0mm Red Terminal CON-TM-351/400 Terminal Markers 351-400 CON-ET10 10.0mm Earth Terminal CON-BB-10 Busbar 10x3mm Copper CON-2.5/10EC End Plate for 2.5mm-10mm Terminals CON-BBS Busbar Support CON-2-2.5 Pluggable Insulated Jumper 2.5mm 2 Way CON-BB-GY4 Busbar Terminal 4mm Green/Yellow CON-10-2.5 Pluggable Insulated Jumper 2.5mm 10 Way CON-BB-BL4 Busbar Terminal 4mm Blue CON-2-4 Pluggable Insulated Jumper 4mm 2 Way CON-BB-GY16 Busbar Terminal 16mm Green/Yellow CON-10- 4 Pluggable Insulated Jumper 4mm 10 Way CON-BB-BL16 Busbar Terminal 16mm Blue CON-2-6 Pluggable Insulated Jumper 6mm 2 Way CON-10- 6 Pluggable Insulated Jumper 6mm 10 Way T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Part Code Description TCS-3 Terminal Connector Strip 12 way 3A TCS-6 Terminal Connector Strip 12 way 6A TCS-15 Terminal Connector Strip 12 way 15A TCS-30 Terminal Connector Strip 12 way 30A Wiring accessories Terminal Connector Strip TCS Cord End Ferrules E/TE German French Description E0508-G E0508-F Pre-insulated cord end terminals 0.5mm² - bag of 1000 E7508-G E7508-F Pre-insulated cord end terminals 0.75mm² - bag of 1000 E1008-G E1008-F Pre-insulated cord end terminals 1.0mm² - bag of 1000 E1508-G E1508-F Pre-insulated cord end terminals 1.5mm² - bag of 1000 E2508-G E2508-F Pre-insulated cord end terminals 2.5mm² - bag of 1000 E4010-G E4010-F Pre-insulated cord end terminals 4.0mm² - bag of 1000 E6012-G E6012-F Pre-insulated cord end terminals 6.0mm² - bag of 1000 E10-12-G E10-12-F Pre-insulated cord end terminals 10mm² - bag of 1000 E16-12-G E16-12-F Pre-insulated cord end terminals 16mm² - bag of 500 TE0508-G TE0508-F Pre-insulated dual cord end terminals 0.5mm² - bag of 1000 TE7508-G TE7508-F Pre-insulated dual cord end terminals 0.75mm² - bag of 1000 TE1008-G TE1008-F Pre-insulated dual cord end terminals 1.0mm² - bag of 1000 TE1508-G TE1508-F Pre-insulated dual cord end terminals 1.5mm² - bag of 1000 TE2510-G TE2510-F Pre-insulated dual cord end terminals 2.5mm² - bag of 1000 Spiral Wrapping CAB Black White Description CAB-06/B CAB-06/W Spiral wrapping band 4-50mm - 10 metres CAB-12/B CAB-12/W Spiral wrapping band 9-65mm - 10 metres CAB-19/B CAB-19/W Spiral wrapping band 15-100mm - 10 metres T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 123 E.C.Products Building Management Controls & Peripherals Wiring accessories E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 124 Cable Ties & Bases Description A range of self-locking nylon cable ties and stainless steel cable ties in a choice of lengths. Part Code Description CAS-2.5X100 Black nylon cable tie 2.5mm x 100mm - pack of 100 CAS-3.5X150 Black nylon cable tie 3.5mm x 150mm - pack of 100 CAS-3.5X200 Black nylon cable tie 3.5mm x 200mm - pack of 100 CAS-4.6X250 Black nylon cable tie 4.6mm x 250mm - pack of 100 CAS-4.6X300 Black nylon cable tie 4.6mm x 300mm - pack of 100 CAS-4.6X350 Black nylon cable tie 4.6mm x 350mm - pack of 100 CAS-4.6X400 Black nylon cable tie 4.6mm x 400mm - pack of 100 CAS-9X550 Black nylon cable tie 9.0mm x 550mm - pack of 100 CAS-12X650 Black nylon cable tie 12mm x 650mm - pack of 100 BZ-C4.6X200 Stainless steel cable tie 4.6mm x 200mm - pack of 100 BZ-C4.6X360 Stainless steel cable tie 4.6mm x 360mm - pack of 100 CS-20 Self-adhesive cable tie mounts 20mm x 20mm - pack of 100 CS-30 Self-adhesive cable tie mounts 30mm x 30mm - pack of 100 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk E.C.Products Building Management Controls & Peripherals Cable CAB Description Technical Specification Panel cable and four core cable, supplied on 100m reels Conductors: Plain annealed flexible copper. Sheath: PVC, heat resistant. Colours: Black, blue, brown, green/yellow, grey, orange, pink, red, violet, white, & yellow Voltage:600/1000V Temperature: Maximum 105°C, minimum Bending 0°C Part Code Description Part Code Description CAB-R-050 Tri-Rated Cable 0.5mm² Red CAB-R-100 Tri-Rated Cable 1mm² Red CAB-BLK-050 Tri-Rated Cable 0.5mm² Black CAB-BLK-100 Tri-Rated Cable 1mm² Black CAB-GY-050 Tri-Rated Cable 0.5mm² Green/yellow CAB-GY-100 Tri-Rated Cable 1mm² Green/yellow CAB-BL-050 Tri-Rated Cable 0.5mm² Blue CAB-BL-100 Tri-Rated Cable 1mm² Blue CAB-Y-050 Tri-Rated Cable 0.5mm² Yellow CAB-Y-100 Tri-Rated Cable 1mm² Yellow CAB-BR-050 Tri-Rated Cable 0.5mm² Brown CAB-BR-100 Tri-Rated Cable 1mm² Brown CAB-V-050 Tri-Rated Cable 0.5mm² Violet CAB-V-100 Tri-Rated Cable 1mm² Violet CAB-P-050 Tri-Rated Cable 0.5mm² Pink CAB-P-100 Tri-Rated Cable 1mm² Pink CAB-W-050 Tri-Rated Cable 0.5mm² White CAB-W-100 Tri-Rated Cable 1mm² White CAB-O-050 Tri-Rated Cable 0.5mm² Orange CAB-O-100 Tri-Rated Cable 1mm² Orange CAB-G-050 Tri-Rated Cable 0.5mm² Grey CAB-G-100 Tri-Rated Cable 1mm² Grey CAB-GR-050 Tri-Rated Cable 0.5mm² Green CAB-GR-100 Tri-Rated Cable 1mm² Green CAB-R-0-75 Tri-Rated Cable 0.75mm² Red CAB-R-150 Tri-Rated Cable 1.5mm² Red CAB-BLK-0-75 Tri-Rated Cable 0.75mm² Black CAB-BLK-150 Tri-Rated Cable 1.5mm² Black CAB-GY-0-75 Tri-Rated Cable 0.75mm² Green/yellow CAB-GY-150 Tri-Rated Cable 1.5mm² Green/yellow CAB-BL-0-75 Tri-Rated Cable 0.75mm² Blue CAB-BL-150 Tri-Rated Cable 1.5mm² Blue CAB-Y-0-75 Tri-Rated Cable 0.75mm² Yellow CAB-Y-150 Tri-Rated Cable 1.5mm² Yellow CAB-BR-0-75 Tri-Rated Cable 0.75mm² Brown CAB-BR-150 Tri-Rated Cable 1.5mm² Brown CAB-V-0-75 Tri-Rated Cable 0.75mm² Violet CAB-V-150 Tri-Rated Cable 1.5mm² Violet CAB-P-0-75 Tri-Rated Cable 0.75mm² Pink CAB-P-150 Tri-Rated Cable 1.5mm² Pink CAB-W-0-75 Tri-Rated Cable 0.75mm² White CAB-W-150 Tri-Rated Cable 1.5mm² White CAB-O-0-75 Tri-Rated Cable 0.75mm² Orange CAB-O-150 Tri-Rated Cable 1.5mm² Orange CAB-G-0-75 Tri-Rated Cable 0.75mm² Grey CAB-G-150 Tri-Rated Cable 1.5mm² Grey CAB-GR-0-75 Tri-Rated Cable 0.75mm² Green CAB-GR-150 Tri-Rated Cable 1.5mm² Green CAB-0000400 4 Core Belden 8723 100m roll T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 Cable E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 125 E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Information Terms and Conditions Deliveries Customers placing orders are taken as having accepted EC Products Limited terms and conditions in full. Many items are available for immediate delivery from our comprehensive stock. However, where delivery is deemed critical, please consult us to avoid disappointment. Setting up an account In order that ECP Limited offer competitive pricing, packing and delivery is charged separately on all orders. Should any company require purchasing product using a credit account, then they should complete and return a Credit Application form. The following shows standard charges for parcels up to 30Kg (heavier parcels are priced individually): Any company wishing to purchase without a credit account will be invoiced on a proforma basis and goods dispatched upon clearance of payment into our bank account. Placing orders The following information is required when placing an order: •Order number •Invoice address •Delivery address (if different from invoice address) •Required delivery date (you will be advised if this cannot be met) •Customer contact •Full description of items required or ECP Limited Part Numbers Orders can be placed by phone, fax, mail or email. Verbal orders should be confirmed in writing. All prices shown in our catalogues are list prices. Credit account customers may be given a discount, which would apply to all products in the catalogue. This discount will only apply in the event of a customer not having negotiated any special prices. Discount will be determined at the discretion of ECP Limited, on the basis of actual turnover expected. Progressing an order To progress an order please contact our office and provide your company name, original date of order and your order number. If your order has been dispatched but not received then a proof of delivery can be provided. Republic of Ireland £28.50 up to 30Kg per parcel. Overseas deliveries will be charged at the prevailing rate. Shipment will be carried out via Interlink Express. If required, a customer collection can be requested, either in person or by an independent carrier. Our trade counter is open From 8.30am to 5.30pm Specials Pricing, discounts and payment Unless agreed in writing with ECP Limited all credit terms are net monthly – defined as payable on or before the last day of the month following the month of invoice. •UK next day before 5.30pm £8.50 Up to 20Kg additional £0.50 per Kg up to 30Kg Max •UK next day before 12 noon £14.50 up to 10Kg additional £0.50 per Kg up to 30Kg Max •UK next day before 10.00am add £18.50 up to 10Kg additional £0.50 per Kg up to 30Kg Max •UK Saturday before 12 noon £25.00 up to 10Kg additional £0.80 per Kg up to 30Kg Max •Northern Ireland £20.00 up to 10Kg additional £1.00 per Kg up to 30Kg Max ECP Limited is always willing to discuss any special requirements for products you may have and many of the products in this catalogue are available with custom labelling and company logos. Please contact our office for full details. Returns Any goods being returned to ECP must be accompanied by a goods return note and shall be inspected upon arrival to determine their condition. Please state in as much detail as possible the reason for the return. No credit will be issues without this information. ECP Limited will credit or replace, at the discretion of the customer, any returned items which are deemed to have failed due to no fault of the customer. When requesting replacements, it is necessary to raise a new and separate purchase order. Credits will then be issued against the original order. Products which are deemed as ‘special products’ will not be accepted for return other than in the case of failure due to no fault of the customer. Goods returned for restocking and in good condition will only be accepted upon payment of a 15% restocking charge, which must be paid by the customer. Goods returned which have been damaged by the customer will be credited at the discretion of ECP Limited. 126 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Terms & conditions 1. Buyer as used herein means the person ordering goods or services from E C Products Limited (ECP). 2. Any of the terms and provisions of the Buyer’s order which are inconsistent with ECP conditions or which are not expressly contained within our documentation as relating to a particular supply or service shall not be binding upon ECP and shall not be considered applicable to that sale. 3. All offers are for supply only and we shall not be governed by any sub-contract conditions that apply to the Buyer. 4. No waiver, alteration or modification of any of the provisions on our quotation, shall be binding unless made in writing and signed by a Director of ECP. 5. Prices quoted are for the quantity mentioned and any increase or reduction may affect price. 6. If after the date of quotation or contract and before completion of work or delivery of goods there shall be an increase in the cost of work or our normal selling price of the goods, then a corresponding increase shall be chargeable and payable by the Buyer. 7. All prices quoted are exclusive of V.A.T. 8. Credit terms are Nett Monthly Account: - defined as payable on or before the last day of the month following that of the date of the invoice. 9. Should no credit agreements or terms exist, between ECP and the buyer, payment shall be on a Pro-Forma basis. 10.ECP reserve the right to suspend supply or service of equipment and any other trading benefits for noncompliance of our terms. 11. The property in all goods supplied by ECP shall remain vested in ECP until the full price of the goods has been paid to ECP. The Buyer shall be responsible for cover against all risks of loss, damage or destruction of such goods until payment is made to ECP. 12.Delivery dates are approximate and ECP shall not be liable for any loss,penalties or damage, direct or indirect, occasioned by delayed delivery and in no case shall delayed delivery be a ground for rejecting goods. 13.No goods may be returned for credit without prior agreement from ECP in writing. Current stock items returned in resaleable condition will be accepted subject to a restocking fee of 15%. 14.Cancellation of orders that have to be made up specially or specifically to the Buyer’s requirements cannot be accepted. 15.All warranties in respect of goods not of our manufacture, the Manufacturer or Distributor warranties will apply. 16.ECP cannot be held responsible for any errors or omissions in drawings after they have been approved by the Buyer. 17. The Buyer shall hold ECP harmless against any loss, damage, or expense resulting from infringement of patents or trade marks arising from compliance by ECP with the Buyer’s design, specification or instruction. 18.All contracts for sale of goods and service will be interpreted in accordance with English Law and any dispute shall be submitted to arbitration under the Laws of England. T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 127 E.C.Products Building Management Controls & Peripherals Suppliers E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH 128 T: +44 (0)20 8569 4100 F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk E.C.Products Building Management Controls & Peripherals E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH J15 /J4b M4 J5 J4 M4 J3 J2 BRENTFORD COLNBROOK A4 A315 A30 A316 HOUNSLOW M25 RICHMOND A315 J13 A4 A4 J14 LONDON HEATHROW AIRPORT J1 Information Please go to www.ecproducts.co.uk to download the lastest data sheets and also for the lastest offers and product releases A30 A30 A244 STAINES A316 A316 FELTHAM TWICKENHAM CKENHAM A TWICKENHA TWICKENHAM K NHA A316 A308 SUNBURY J1 KINGSTON NG TON T KINGSTON UPO UPON PO ON N THAMES T HAM HA A A308 GR E EN NE LA J13 /J2 A309 A315 Y WAY AMBERLE D SR GG FA M3 ST E AI N D SR A315 D HOUNSLOW HEATH RD W HO N TO NG RLI E. C. Products Limited U NS LOW RD R INES HA STA Distributors for Central and Eastern Europe JSC RATECHNA Gerosios Vilties 20-18A Vilnius, LT-03145 Lithuania Tel: +370 655 76 555 sales@ratechna.lt www.ratechna.lt Distributors for Russia, Belorussia, Ukraine JSC SATORIS Vasilevsky Ostrov 8-ya Liniya, 77,B RU 199178 St.Petersburg Russia EC House Amberley Way Hounslow Middlesex, TW4 6BH Tel: +44 (0)20 8569 4100 T: +44 (0)20 8569 4100 Tel: +7 812 640 9801 info@satoris.ru www.satoris.ru F: +44 (0)20 8569 4111 E: sales@ecproducts.co.uk W: www.ecproducts.co.uk 129 E. C. Products Limited, EC House, Amberley Way, Hounslow, Middlesex, TW4 6BH Phone: 020 8569 4100 Fax: 020 8569 4111 Email: sales@ecproducts.co.uk www.ecproducts.co.uk