5896.artwork 16/11/00 10:49 am Page 1 Precision Instruments This high current, digital, direct reading, microprocessor based transformer ohmmeter will measure the D.C. resistance of power transformers and other electrical devices where high inductance is also present. With a choice of single or dual measuring channels (models 5896 or 5896b). With a fast initial settling time this ohmmeter provides the best overall solution to DC resistance testing of transformers. Notoriously difficult transformer types including 3 phase closed delta and autotape changers. Small pole mounted to large distribution types with 3 or 5 limb construction are easily measured using the 5896. With 6 ranges from 2 millohms to 190 ohms, a choice of 2 current per range, and a basic accuracy of 0.1%. The single or dual channel measurement of primary or primary and secondary transformer winding resistance is displayed on a large LCD screen to 4 1/2 digit resolution. An advanced, high power, wide ranging ohmmeter for fast accurate measurements of transformers or Features other inductive loads. With built-in data storage and One or two independent measuring channels interfacing to PC or external printer. Suitable for a High current (25A) wide range of factory, on-site plant measurement High accuracy (0.1%) and performance testing applications including: High resolution to 0.1µohm • Transformer dc winding resistance 41⁄2 digit large display to 19000 • Generator stator/rotor resistance Wide range 1 milliohm to 190 ohms • Large motors Rapid saturation to read time on Y-∆ transformers (>30 secs) • Power utility sub-stations • Transformer tap-changer operation and contact tests • Routine plant maintenance and “Benchmarking” • Storage of data on internal memory Built-in printer for time and readings records. Constant current regulated supply eliminates Ldi⁄dt effects for fault finding 6 ranges, choice of two currents/range Factory testing to international standards. Large LCD screen for data presentation • Transformer “Heat-run” tests RS232/IEEE488 computer interface • Power connections and circuit breaker testing Over temperature protection 5896.artwork 16/11/00 10:50 am Page 2 Precision Instruments Technical Data Features and Benefits The 5896 is microprocessor The use of special current control based with menu driven options circuits enables large transformers selected via front panel controls. particularly closed delta types to With electronic calibration, the be quickly saturated enabling the instrument can be easily initial first reading to be made recalibrated against known within 60 seconds for most external standards. User transformers. This is important controlled internal software when making “heat-run” tests to allows data logging and storage comply with various international of measurements in the standards. In addition the special instruments internal memory. circuits employed limit the Ldi The RS2323/IEEE488 interface effects that can give rise to noise enables stored data to be down and unstable readings. loaded to a computer or external printer. The instrument may also be fully controlled via the interface. When testing tap-changers where accurate measurement of contact resistance of the taps is important the high resolution of the 5896, to 1 part in 19000, provides an accurate means to detect potential problems. Model 5896 Specification Range Nominal Value Full Range Display Current High - Low Resolution Accuracy 1 2 1mΩ 1.9000mΩ 25A-10A 0.1µΩ ±0.1% 10mΩ 19.999mΩ 25A-10A 1.0µΩ ±0.1% 3 100mΩ 190.00mΩ 10A-5A 10µΩ ±0.1% 4 1Ω 1.9000Ω 5A-1A 0.1mΩ ±0.1% 5 10Ω 19.000Ω 1A-0.25A 1.0mΩ ±0.1% 6 100Ω 190.00Ω 0.25A-0.1A 10mΩ ±0.1% Measuring time Environment: Initial first reading (saturation time of transformers) • 0 TO 45°C at 50/RH non condensing Typically 4 to 60 seconds • Dimensions 470x204x350mm Normal reading rate 2 seconds • Nett weight 32kg Accessories: Inputs: • Calibration certificate traceable to National Standards - included Measuring: 2 current and 2 voltage/channels (isolated) • Soft padded. heavy duty case for on-site protection - included Mains: 100/120/220/240V 50 to 60 Hz • Connection cable sets - extra Outputs: RS232C IEEE488 option Number of inputs Printer: built-in paper strip Model 5896 1 Channel Ordering information and accessories Model 5896B 2 Channels 5896 Single Channel with RS232 5896B 2 Channel for two winding measurement with RS232 5896/IE Single Channel R5232 and IEEE488 5896B/IE 2 channel with R52322 and IEEE488 5896IE IEE488 Option (retrofit) 5896-2CH Second channel option for (5896 retrofit) 5896/Cl 4 metre 4 wire 25A Cable Set 5896/C2 12 metre 4 wire 25A Cable Set 5896/C3 20 metre 4 wire 25A Cable Set 5896/PP Printer Paper (10 rolls) Display LCD Screen 70x127mm displaying: selected current, time, date, range and resistance value for 2 channels Overall range: 0.lµΩ to190Ω in 6 ranges Overall accuracy: ±0.l% of reading ± I digit Resolution: 0.1µΩ to 10mΩ over 6 ranges (0.005% / I part in 20 000) Test currents: 0.IA to 25A max 5896/4737B Calibration unit 275 King Henry’s Drive, New Addington, Croydon, CR0 0AE, England Telephone 44 (0) 1689 800799 Fax 44 (0) 1689 800405 0057