Pricing and selection guide Emax Low voltage power circuit-breakers Emax power breakers 16 Po we Em r b ax re ak e Emax Power Breakers ............................ 16.1 - 16.74 General information ...........................................16.1 Emax UL ..........................................................16.11 Emax IEC .........................................................16.19 Trip units and rating plugs ...............................16.29 Accessories .....................................................16.31 Dimensions ......................................................16.37 Request for quote form ...................................16.79 16 Emax Power breakers rs This catalog is published for information purposes only and is not all inclusive. For additional information on products or technical information, consult ABB Inc. The installation and use if ABB Inc. products should be in accordance with the provisions of the U.S. National Electrical Code and/or other local codes or industry standards that are pertinent to the articular end use. Installation or use not in accordance with codes and standards could be hazardous to personnel and/or equipment. Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.A LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow Notes P 16 16.B LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Emax power breakers 16 Po we Em r b ax re ak e ABB’s Emax series of low voltage power circuit breakers embodies over half a century’s experience and technological development in power circuit breakers. The Emax offers a series of breakers that is totally innovative in its technological design, ease of installation and use, making it the ideal solution for the growing requirements of designers, switchboard and switchgear manufacturers, installers, OEMs and users. The Emax power circuit breakers are UL Listed and meet the ANSI and IEC Standards for low voltage power circuit breakers. ABB Emax power circuit breakers are available in five different models with rated continuous current from 800A to 6300A and rated short-circuit current range from 42kA to 200kA (480V). UL File # E194191 UL Technical catalog 1SDC200005D0201 is available at: http://www.abb-control.com/pdf/ catalog/1SDC200005D0201.pdf 16 Emax Power breakers rs Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.1 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow General information General ratings and specifications P E1 UL 1066 Levels of performance Frame Size Capacity of neutral pole for four-pole circuit breakers Rated short circuit current 240V 480V 600V Rated short time current E2 E1 E3 E2 E3 B-A 800 1200 — — — — 100 N-A 800 1200 — — — — 100 B-A 1600 — — — — — 100 N-A 800 1200 1600 — — — 100 S-A 800 1200 1600 — — — 100 H-A 800 1200 1600 — — — 100 N-A 2000 2500 — — — — 100 S-A 800 1200 1600 2000 2500 3200 100 H-A 800 1200 1600 2000 2500 3200 100 V-A 800 1200 1600 2000 2500 3200 100 X-A 800 1200 1600 2000 — — — 42 42 42 42 50 50 50 50 42 42 42 42 65 50 50 50 65 65 65 65 85 85 65 65 65 50 50 50 85 65 65 65 85 85 85 65 125 125 100 85 200 200 14 14 B 800 1000 1250 1600 — — — 100 N 800 1000 1250 1600 — — — 100 B 1600 2000 — — — — — 100 N 1000 1250 1600 2000 — — — 100 S 800 1000 1250 1600 2000 — — 100 L 1250 1600 — — — — — 100 N 2500 3200 — — — — — 100 S 1000 1250 1600 2000 2500 3200 — 100 H 800 1000 1250 1600 2000 2500 3200 100 V 800 1250 1600 2000 2500 3200 — 100 L 2000 2500 — — — — — 100 [kA] [kA] [kA] [kA] 42 42 42 42 50 50 50 50 42 42 42 42 65 65 55 55 85 85 65 65 130 110 85 85 65 65 65 65 75 75 75 75 100 100 100 85 130 130 100 100 130 110 85 85 [kA] [kA] [kA] [kA] [kA] 42 42 42 42 42 50 50 50 50 50 42 42 42 42 42 65 65 55 55 55 85 85 65 65 65 130 110 65 65 10 65 65 65 65 65 75 75 75 75 75 85 85 85 85 75 100 100 85 85 85 130 110 65 65 15 [A] [A] [A] [A] [A] [A] [%Iu] [kA] [kA] [kA] [kA] IEC 60947-2 Levels of performance Currents: rated uninterrupted current (at 40°C) Iu 16 Capacity of neutral pole for four-pole circuit breakers Rated ultimate breaking capacity under short circuit Icu 220/230/380/400/415V 440V 500/525V 660/690V Rated service breaking capacity under short circuit Ics 220/230/380/400/415V 440V 500/525V 660/690V Rated short time withstand current Icw (1s) [A] [A] [A] [A] [A] [A] [A] [%Iu] UL 1066 and IEC 60947-2 3 Overall dimensions Fixed: H = 418mm/16.46 in; D = 302 mm/11.89 in W (3 poles/4 poles) W (3 poles/4 poles) [mm] [in] 296/386 11.65/15.2 Draw out: H = 461mm/18.15 in; D = 396.5 mm/15.61 in W (3 poles/4 poles) [mm] 324/414 W (3 poles/4 poles) [in] 12.76/16.3 Weights (circuit breaker complete with trip unit, RH terminals, CS, excluding accessories) Fixed 45/54 3 poles/4 poles [Kg] 3 poles/4 poles [lbs] 99/119 Draw out 3 poles/4 poles [Kg] 70/82 3 poles/4 poles [lbs] 154/181 1 four poles only 2 100% neutral protection 3 For X Versions, see page 16.7. 16.2 LV040 [1SXU200040C0202] - 10/07 296/386 11.65/15.2 404/530 15.91/20.82 324/414 12.76/16.3 432/558 17.01/21.97 50/61 110/134 66/80 145/176 78/93 172/205 104/125 229/275 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 Po we Em r b ax re ak e General information General ratings and specifications rs E4 UL 1066 E4 Capacity of neutral pole for four-pole circuit breakers Rated short circuit current 240V 480V 600V Rated short time current E6 H-A/f S-A H-A V-A L-A H-A V-A L-A X-A 3200 3600 — — — — 50 3200 3600 — — — — 50 3200 3600 — — — — 50 3200 3600 — — — — 50 3200 3600 — — — — 100 4000 5000 — — — — 50 4000 5000 — — — — 50 4000 5000 — — — — 50 4000 5000 — — — — 50 4000 5000 — — — — 100 4000 5000 — — — — 100 85 65 65 65 100 85 85 85 100 100 100 100 125 125 100 100 100 85 85 85 125 85 85 100 125 125 100 100 150 150 100 100 200 200 100 100 125 85 85 100 200 200 1000 100 S 4000 — — — — — — 50 H 3200 4000 — — — — — 50 V 3200 4000 — — — — — 50 S/f 1 4000 — — — — — — 100 H/f 1 3200 4000 — — — — — 100 H 4000 5000 6300 — — — — 50 V 3200 4000 5000 6300 — — — 50 H/f 1 4000 5000 6300 — — — — 100 [kA] [kA] [kA] [kA] 75 75 75 75 100 100 100 85 150 150 130 100 80 80 75 75 100 100 100 100 100 100 100 100 150 150 130 100 100 100 100 100 [kA] [kA] [kA] [kA] [kA] 75 75 75 75 75 100 100 100 85 100 150 150 130 100 100 80 80 75 75 80 100 100 100 100 85 100 100 100 100 85 125 125 100 100 85 100 100 100 100 100 Levels of performance Frame Size E6 [A] [A] [A] [A] [A] [A] [%Iu] [kA] [kA] [kA] [kA] 1 H-A/f 1 X-A/f 1 IEC 60947-2 Levels of performance Currents: rated uninterrupted current (at 40°C) Iu Capacity of neutral pole for four-pole circuit breakers Rated ultimate breaking capacity under short circuit Icu 220/230/380/400/415V 440V 500/525V 660/690V Rated service breaking capacity under short circuit Ics 220/230/380/400/415V 440V 500/525V 660/690V Rated short time withstand current Icw (1s) [A] [A] [A] [A] [A] [A] [A] [%Iu] 16 UL 1066 and IEC 60947-2 3 Overall dimensions Fixed: H = 418mm/16.46 in; D = 302 mm/11.89 in W (3 poles/4 poles) W (3 poles/4 poles) [mm] [in] 566/656 22.28/25.83 Draw out: H = 461mm/18.15 in; D = 396.5 mm/15.61 in W (3 poles/4 poles) [mm] 594/684 W (3 poles/4 poles) [in] 23.39/26.93 Weights (circuit breaker complete with trip unit, RH terminals, CS, excluding accessories) Fixed 3 poles/4 poles [Kg] 97/117 3 poles/4 poles [lbs] 214/258 Draw out 3 poles/4 poles [Kg] 147/165 3 poles/4 poles [lbs] 324/363 1 four poles only 2 100% neutral protection 3 For X Versions, see page 16.7. Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 7462 29.37 782/908 30.79/35.78 10342 40.71 7742 30.47 810/936 31.89/36.85 10622 41.81 1252 276 140/160 308/353 1852 408 2002 441 210/240 463/529 2752 607 10/25/07 Rev. 16.3 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow General information Catalog number information Emax breaker P D 3 V E H B A H 0 A 0 0 0 X X Locking provisions: X = none; A = keylock (open) B = button guard C = padlock provision (open) D = withdrawable position lock (connected, test, and disconnected positions E = withdrawable position lock (test, and disconnected positions) F=A+B; G=A+C; H=A+D; J=A+E; K=B+D; L=B+E; M=C+D; N=C+E; P=A+B+D; Q=A+B+E; R=A+C+D; S=A+C+E; T=heavy duty padlock provision (open); U=A+T; V=T+D; W=T+E; Y=A+T+D; Z=A+T+E Accessories: X=none; A=mechanical counter; B = bell alarm C=bell alarm w/remote reset 24-30VAC/DC D=bell alarm w/remote reset 110-130VAC/DC E=bell alarm w/remote reset 220-240VAC/DC F=A+B; G=A+C; H=A+D; J=A+E Undervoltage trip: 0=none 50/60Hz & VDC: A=24VDC C=48V E=110-120V G=220-240V J=380-400VAC Second shunt trip: L=24VDC N=48V Q=110-120V S=220-240V U=380-400VAC B=30V D=60V F=125-127V H=250V K=440-480VAC M=30V P=60V R=125-127V T= 250V V=440-480VAC Shunt trip: 0 = none 50/60Hz & VDC: A=24VDC; B=30; C=48; D=60; E=110-120; F=125-127; G=220-240, H=250; J=380-400VAC; K=440-480VAC; L=special low Z=120-127VAC/DC Spring charging motor: (includes spring charged signal, P/N does not show) 0=none, A=24-30VAC/VDC, B=48-60VAC/VDC, C=110-130VAC/VDC, D=220-250VAC/VDC, E=spring charged signal only Contacts: A=4 aux B=10 aux D=UV energ. N.O. F=A & D G=A & E H=B & D (15 auxiliary contacts available as separate accessory) E=UV energ. NC J = B & E Closing coil: 0=none 50/60Hz & VDC: A=24VDC; B=30; C=48; D=60; E=110-120; F=125-127; G=220-240; H=250; J=380-400VAC; K=440-480VAC 16 Trip unit accessories: (not compatible with PR121/P) A=PR120/K4C; B=PR120/V (bottom; supplied as std on PR123/P); C=PR120/D-M; D=PR120/D-BT; E=A+B; F=A+C; G=A+D; H=A+B+C; I=A+B+D; J=B+C+D; K=A+C+D; L=A+B+C+D; M=B+C; N=PR120/V (top); P=A+N; Q=A+N+C; R=A+N+D; S=N+C+D; T=A+N+C+D; U=N+C; V=B+D; W=N+D; 0=none Trip unit:A=PR121/P, LI; B=PR121/P, LSI; C=PR121/P, LSIG; D=non-automatic; E=PR122/P, LI; F=PR122P, LSI G=PR122/P, LSIG; H=PR122/P, LSIRc1 J=PR123/P, LSI + PR120/V; K=PR123/P, LSIG + PR120/V Version:B=UL fixed3; D=UL drawout, less cradle; F=IEC fixed3; W=IEC drawout, less cradle Rating plug: A=400; B=600/630; C=800; D=1000; E=1200/1250; F=1600; G=2000; H=2500; J=30002; K=3200, L=36002; M=4000; N=5000; P=63001; 0=None (Non-automatic only) Frame ampere rating: : A=800; B=1200/1250; C=1600; D=2000; E=2500; F=3200; G=3600; H=4000; J=5000, N=63001; P=10001 Breaking capacity: B=basic; N=normal; S=standard; H=high; V=very high; L=limiting; Q=1000VAC, R=750VDC (3P) 1000VDC (4P)5; X=200kA4 Frame size: 1=E1, 3P; 2=E2, 3P; 3=E3, 3P; 4=E4, 3P; 6=E6, 3P; A=E1, 4P; B=E2, 4P, C=E3, 4P; D=E4, 4P; (50% neutral); F=E6, 4P (50% neutral); G=E4, 4P (100% neutral); H=E6, 4P (100% neutral) 1 IEC only 2 UL only 3 Horizontal terminals are standard except for the E3 3200A; for vertical terminals, see page 16.36 for conversion kit. 4 Available as E3 up to 2000A and E6 up to 5000A. 5 Consult factory. 16.4 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com General information Catalog number information Emax, cradle (fixed part) D 3 S 2 5 16 Po we Em r b ax re ak e rs V A X Options5: X=none R=DC rated (750V 3P, 1000V 4P)1 Contacts: 0=none A=5 position auxiliaries, TOC B=10 position auxiliaries, TOC Terminal types: (1st letter is upper terminal, 2nd letter is lower terminal) UL/IEC: H=rear horz. (H=HH); V=rear vert. (V=VV); A=HV; B=VH IEC ONLY: F=front; L=rear flat; F=FF; L=LL; C=HF; D=FH; E=HL; G=LH; J=VF; K=FV; M=VL; N=LV; P=FL; Q=LF Max. ampere rating: UL: 12=1200 (E1); 16=1600 (E2); 20=2000 (E3)3; 25=2500 (E3); 32=3200 (E3)4, 36=3600 (E4); 50=5000 (E6) IEC: 16=1600 (E1); 20=2000 (E2); 32=3200 (E3); 40=4000 (E4); 63=6300 ( E6) Version: UL: N=E1B-A; E1N-A; E2B-A; E2N-A; H=E2S-A; E2H-A; E4S-A; E4H-A; E4H-A/f; E6H-A; E6H-A/f; S=E3N-A; E3S-A; V=E3H-A; E3V-A; L=E4V-A; E4L-A; X=E3X-A2; E6V-A; E6L-A; E6X-A IEC:C=IEC Cradle Frame size: 1=1, 3P; 2=2, 3P; 3=3, 3P; 4=4, 3P; 6=6, 3P; A=1, 4P; B=2, 4P; C=3, 4P; D=4, 4P (50% neutral); F=6, 4P (50% neutral); G=4, 4P (100% neutral); H=6, 4P (100% neutral) 16 1 IEC only 2 Available as E3 up to 2000A 3 Vertical only up to 2000A 4 Vertical only 5 Consult factory for pricing Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.5 LV040 [1SXU200040C0202] - 10/07 16 rs Circuit Breakers ax ke UL circuitUL Emax breakers Em rea er w Po b Rated maximum voltage Rated voltage Test voltage (1 min. 50/60 Hz) [V] [V] [kV] 635 600 2.2 Frequency [Hz] Version Fixed (F) - Draw out (W) Number of poles 1SDC200008F0201 Voltages 1SDC200007F0201 Common data 50 - 60 3-4 E1 Level of performance Currents Frame size [A] [A] [A] [A] [A] [A] [%Iu] E2 B-A N-A B-A N-A S-A H-A 800 1200 800 1200 1600 800 1200 1600 800 1200 1600 800 1200 1600 100 100 100 100 42 42 42 42 65 50 50 50 65 65 65 65 85 85 65 65 80 70 30 80 70 30 80 70 30 80 70 12 Capacity of neutral pole for four-pole circuit breakers 100 100 Rated short circuit current 240 V [kA] 42 50 480 V [kA] 42 50 600 V [kA] 42 50 Rated short time current [kA] 42 50 Trip units PR121/P PR122/P PR123/P Trip times Make time (max) [ms] 80 80 Break time (I<ST current) (max) [ms] 70 70 Break time (I>ST current) (max) [ms] 30 30 Overall dimensions Fixed: H = 418 mm/16.46 in - D = 302 mm/11.89 in * W (3 poles/4 poles) [mm] 296/386 W (3 poles/4 poles) [in] 11.65/15.2 Draw out: H = 461 mm/18.15 in - D = 396.5 mm/15.61 in ** W (3 poles/4 poles) [mm] 324/414 W (3 poles/4 poles) [in] 12.76/16.3 Weights (Circuit breaker complete with trip unit, RH terminals, CS, excluding accessories) Fixed 3 poles/4 poles [kg] 45/54 3 poles/4 poles [lbs] 99/119 Draw out 3 poles/4 poles [kg] 70/82 3 poles/4 poles [lbs] 154/181 16 296/386 11.65/15.2 324/414 12.76/16.3 50/61 110/134 78/93 172/205 (1) four poles only. * for E3X-A: H = 438 mm/ 17.24 in - D = 302 mm/ 11.89 in ** for E3X-A: H = 481 mm/ 18.94 in - D = 396.5 mm/ 15.61 in E1 B-A / N-A Continuous current rating Iu Mechanical life with regular ordinary maintenance Operation frequency Electrical life Operation frequency E2 B-A / N-A / S-A / H-A [A] 800 1200 800 1200 1600 [No. Operations x 1000] 20 20 20 20 20 [Operations/hour] 30 30 30 30 30 [No. Operations x 1000] 10 10 10 10 10 [Operations/hour] 30 30 30 30 30 (2) 10 for E3X-A. (3) 1.5 for E3X-A. 16.6 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 Po we Em r b ax re ak e UL Circuit Breakers 1SDC200011F0201 1SDC200010F0201 1SDC200009F0201 rs E3 E4 E6 N-A S-A H-A V-A X-A S-A H-A V-A L-A 2000 2500 800 1200 1600 2000 2500 3200 100 800 1200 1600 2000 2500 3200 100 800 1200 1600 2000 3200 3600 3200 3600 3200 3600 3200 3600 100 800 1200 1600 2000 2500 3200 100 100 50 50 50 65 50 50 50 85 65 65 65 85 85 85 65 125 125 100 85 200 200 14 14 85 65 65 65 100 85 85 85 80 70 30 80 70 30 80 70 30 80 70 30 80 70 30 80 70 30 80 70 30 H-A/f H-A/f (1) X-A/f(1) H-A V-A L-A X-A 3200 3600 4000 5000 4000 5000 4000 5000 4000 5000 4000 5000 4000 5000 50 100 50 50 50 50 100 100 100 100 100 100 125 125 100 100 100 85 85 85 125 85 85 100 125 125 100 100 150 150 100 100 200 200 100 100 125 85 85 100 200 200 100 100 80 70 30 80 70 30 80 70 30 80 70 30 80 70 30 80 70 30 80 70 30 80 70 30 80 70 30 (1) 404/530 15.91/20.82 566/656 22.28/25.83 746 29.37 782/908 30.79/35.78 1034 40.71 432/558 17.01/21.97 594/684 23.39/26.93 774 30.47 810/936 31.89/36.85 1062 41.81 66/80 145/176 70/84 154/185 97/117 214/258 125 276 140/160 308/353 185 408 104/125 229/275 106/128 233/282 147/165 324/363 200 441 210/240 463/529 275 607 E4 S-A / H-A / V-A / L-A / H-A/f E3 N-A / S-A / H-A / V-A E6 H-A / V-A / L-A / X-A / H-A/f / X-A/f 800 1200 1600 2000 2500 3200 3200 3600 4000 15(2) 15(2) 15(2) 15(2) 15 15 8 8 8 8 30 30 30 30 30 30 30 30 30 30 10(3) 10(3) 10(3) 8(3) 8 8 5 5 5 3 30 30 30 30 30 30 30 30 30 30 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 5000 16.7 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow UL Non-automatic air circuit breakers P The switches share the same frames and accessories as the circuit breakers, with the only difference the absence of the trip unit. The switch is available in both three-pole and four-pole fixed and draw out version and is identified by the code "/MS" (on the label). The electrical characteristics of the switches are given in the following table. Frame size Number of Poles Capacity of neutral pole for four-pole circuit breakers Rated voltage Rated maximum voltage Test voltage (1 min. 50/60 Hz) Frequency Rated short time current Version [A] [A] [A] [A] [A] [A] [%Iu] [V] [V] [kV] [Hz] [kA] E1B-A/MS 800 1200 — — — — 3/4 100 600 635 2.2 50-60 42 F -W E1N-A/MS 800 1200 — — — — 3/4 100 600 635 2.2 50-60 50 F -W E2B-A/MS 1600 — — — — — 3/4 100 600 635 2.2 50-60 42 F -W E2 N-A/MS 800 1200 1600 — — — 3/4 100 600 635 2.2 50-60 50 F -W E2S-A/MS 800 1200 1600 — — — 3/4 100 600 635 2.2 50-60 65 F -W E3N-A/MS 2000 2500 — — — — 3/4 100 600 635 2.2 50-60 650 F -W E3S-A/MS 800 1200 1600 2000 2500 3200 3/4 100 600 635 2.2 50-60 650 F -W 16 16.8 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 Po we Em r b ax re ak e Non-automatic switches UL Frame size Number of Poles Capacity of neutral pole for four-pole circuit breakers Rated voltage Rated maximum voltage Test voltage (1 min. 50/60 Hz) Frequency Rated short time current Version [A] [A] [A] [A] [A] [A] [%Iu] [V] [V] [kV] [Hz] [kA] E4S-A/MS 3200 3600 — — — — 3/4 50 600 635 2.2 50-60 65 F -W E4H-A/MS 3200 3600 — — — — 3/4 50 600 635 2.2 50-60 85 F -W rs E4V-A/MS 3200 3600 — — — — 3/4 50 600 635 2.2 50-60 100 F -W E4H-Af/MS 3200 3600 — — — — 4 50 600 635 2.2 50-60 85 F -W E6H-A/MS 4000 5000 — — — — 3/4 50 600 635 2.2 50-60 100 F -W E6H-Af/MS 4000 5000 — — — — 4 100 600 635 2.2 50-60 100 F -W 16 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.9 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow Electronic trip units Rating plugs P Rating plugs Type of circuit breaker E1B-A E2B-A E2N-A E2S-A E2H-A E3N-A E3S-A E3H-A E3V-A E3X-A E4S-A 16 E4H-A E4V-A E4L-A E6H-A E6V-A E6L-A E6X-A Rated current Iu In [A] 400 600 800 800 1200 1600 800 1200 1600 800 1200 1600 800 1200 1600 2000 2500 800 1200 1600 2000 2500 3200 800 1200 1600 2000 2500 3200 800 1200 1600 2000 2500 3200 800 1200 1600 2000 3200 3600 3200 3600 3200 3600 3200 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 1000 1200 1600 2000 2500 3000 3200 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 3600 4000 5000 • • • • 3600 • • • • • • • • • • 4000 • • • • • • • • • • 5000 • • • • • • • • • • 4000 • • • • • • • • • • 5000 • • • • • • • • • • 4000 • • • • • • • • • • 5000 • • • • • • • • • • 4000 • • • • • • • • • • 5000 • • • • • • • • • • 16.10 LV040 [1SXU200040C0202] - 10/07 • • • • Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 Po we Em r b ax re ak e Fixed breakers, 3 pole UL rs Fixed breakers Manually Operated Electrically Operated Set of Three Vertical Terminals UL Frame Amps Interrupting Ratings kA, 480V E1B-A08 E1N-A08 E2N-A08 E2S-A08 E2H-A08 E3S-A08 E3H-A08 E3V-A08 E3X-A08 E1B-A12 E1N-A12 E2N-A12 E2S-A12 E2H-A12 E3S-A12 E3H-A12 E3V-A12 E3X-A12 800 800 800 800 800 800 800 800 800 1200 1200 1200 1200 1200 1200 1200 1200 1200 42 50 50 65 85 65 85 125 200 42 50 50 65 85 65 85 125 200 $ 6,815 6,933 7,729 8,458 8,664 8,755 8,931 9,926 11,678 7,321 7,429 7,819 8,712 8,835 8,780 9,048 9,953 11,709 $ 9,176 9,294 10,090 11,819 11,025 11,116 11,292 12,287 14,039 9,682 9,790 10,180 11,073 11,196 11,141 11,409 12,314 14,070 $ 644 644 690 690 690 790 790 790 790 644 644 690 690 690 790 790 790 790 E2B-A16 E2N-A16 E2S-A16 E2H-A16 E3S-A16 E3H-A16 E3V-A16 E3X-A16 1600 1600 1600 1600 1600 1600 1600 1600 42 50 65 85 65 85 125 200 7,871 9,082 9,764 10,019 9,797 10,352 11,387 13,396 10,232 11,443 12,125 12,380 12,158 12,713 13,748 15,757 690 690 690 690 790 790 790 790 E3N-A20 E3S-A20 E3H-A20 E3V-A20 E3X-A20 2000 2000 2000 2000 2000 50 65 85 125 200 10,032 11,053 13,602 14,962 17,603 12,393 13,414 15,963 17,323 19,964 790 790 790 790 790 E3N-A25 E3S-A25 E3H-A25 E3V-A25 2500 2500 2500 2500 50 65 85 125 14,778 16,451 17,708 19,479 17,139 18,812 20,069 21,840 790 790 790 790 E3S-A32 E3H-A32 E3V-A32 E4S-A32 E4H-A32 E4V-A32 E4L-A32 3200 3200 3200 3200 3200 3200 3200 65 85 125 65 85 100 150 23,242 23,929 26,488 21,102 21,566 24,047 27,812 25,603 26,290 28,849 23,463 23,927 26,408 30,173 E4S-A36 E4H-A36 E4V-A36 E4L-A36 3600 3600 3600 3600 65 85 100 150 23,939 27,302 28,666 29,203 26,300 29,663 31,027 31,564 1,664 1,664 1,664 1,664 E6H-A40 E6V-A40 E6L-A40 E6X-A40 4000 4000 4000 4000 85 125 150 200 31,528 43,932 50,399 53,052 33,889 46,293 52,760 55,413 2,783 2,783 2,783 2,783 E6H-A50 E6V-A50 E6L-A50 E6X-A50 5000 5000 5000 5000 85 125 150 200 43,221 51,684 55,439 58,356 45,582 54,045 57,800 60,717 2,783 2,783 2,783 2,783 6 Vertical Terminals are Standard 1,664 1,664 1,664 1,664 Standard features – manually operated UL breaker • • • • • • • • • Rear horizontal terminals except where noted PR121 trip unit with LI protection functions Manual mechanical close and open pushbuttons CB open/closed mechanical indicator Spring charged/discharged mechanical indicator 2NO & 2NC auxiliary contacts for open/closed position indication Lifting plates Current transformers Terminal box Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Discount schedule ED1 - ED6 16.11 LV040 [1SXU200040C0202] - 10/07 16 16 rs ax ake m E bre er ow Fixed breakers, 4 pole UL P Fixed breakers UL 16 Interrupting Ratings kA, 480V Manually Operated E1B-A08 E1N-A08 E2N-A08 E2S-A08 E2H-A08 E3S-A08 E3H-A08 E3V-A08 E3X-A08 800 800 800 800 800 800 800 800 800 42 50 50 65 85 65 85 125 200 $ 9,200 9,323 9,662 10,587 10,851 10,970 11,197 12,495 15,765 $ 11,561 11,684 12,023 12,948 13,212 13,331 13,558 14,856 18,126 $ 870 870 935 935 935 1,067 1,067 1,067 1,067 E1B-A12 E1N-A12 E2N-A12 E2S-A12 E2H-A12 E3S-A12 E3H-A12 E3V-A12 E3X-A12 1200 1200 1200 1200 1200 1200 1200 1200 1200 42 50 50 65 85 65 85 125 200 9,883 10,038 10,556 11,826 11,903 11,853 12,215 13,436 15,807 12,244 12,399 12,917 14,187 14,264 14,214 14,576 15,797 18,168 870 870 935 935 935 1,067 1,067 1,067 1,067 E2B-A16 E2N-A16 E2S-A16 E2H-A16 E3S-A16 E3H-A16 E3V-A16 E3X-A16 1600 1600 1600 1600 1600 1600 1600 1600 42 50 65 85 65 85 125 200 10,626 12,261 12,978 13,121 13,226 13,975 15,373 18,085 12,987 14,622 15,339 15,482 15,587 16,336 17,734 20,446 935 935 935 935 1,067 1,067 1,067 1,067 E3N-A20 E3S-A20 E3H-A20 E3V-A20 E3X-A20 E3N-A25 E3S-A25 E3H-A25 E3V-A25 2000 2000 2000 2000 2000 2500 2500 2500 2500 50 65 85 125 200 50 65 85 125 13,543 14,922 18,363 20,199 23,763 19,950 22,209 23,906 26,296 15,904 17,283 20,724 22,560 26,124 22,311 24,570 26,267 28,657 1,067 1,067 1,067 1,067 1,067 1,067 1,067 1,067 1,067 E3S-A32 E3H-A32 E3V-A32 E4S-A32 E4H-A32 E4H-A/f32 1 E4V-A32 E4L-A32 3200 3200 3200 3200 3200 3200 3200 3200 65 85 125 65 85 85 100 150 29,772 30,081 33,340 28,488 29,114 31,916 32,463 35,712 32,133 32,442 35,701 30,849 31,475 34,277 34,824 38,073 8 Vertical Terminals are standard 2,250 2,250 2,572 2,250 2,250 E4S-A36 E4H-A36 E4H-A/f36 1 E4V-A36 E4L-A36 3600 3600 3600 3600 3600 65 85 85 100 150 32,318 36,858 39,866 38,669 40,931 34,679 39,219 42,227 41,060 43,292 2,250 2,250 2,572 2,250 2,250 E6H-A40 E6H-A/f40 1 E6V-A40 E6L-A40 E6X-A40 E6X-A/f40 4000 4000 4000 4000 4000 4000 85 85 125 150 200 200 42,563 46,110 59,308 65,076 71,620 81,851 44,924 48,471 61,669 67,437 73,981 84,212 3,757 4,294 3,757 3,757 3,757 4,294 E6H-A50 E6H-A/f50 1 E6V-A50 E6L-A50 E6X-A50 E6X-A/f50 5000 5000 5000 5000 5000 5000 85 85 125 150 200 200 58,348 65,097 69,773 71,628 78,781 90,035 60,709 67,458 72,134 73,989 81,142 92,396 3,757 4,294 3,757 3,757 3,757 4,294 Standard features – manually operated UL breaker Neutral pole rating • • • • • • • • • • E1 – E3 = 100% rating • E4 – E6 = 50% rating Rear horizontal terminals except where noted PR121 trip unit with LI protection functions Manual mechanical close and open pushbuttons CB open/closed mechanical indicator Spring charged/discharged mechanical indicator 2NO & 2NC auxiliary contacts for open/closed position indication Lifting plates Current transformers Terminal box Electrically Operated Set of Four Vertical Terminals Frame Amps 1 Special 100% neutral pole rating. 16.12 LV040 [1SXU200040C0202] - 10/07 Discount schedule ED1 - ED6 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 Po we Em r b ax re ak e Withdrawable breakers, 3 pole UL rs Withdrawable breakers UL Frame Amps Interrupting Ratings kA, 480V Manually Operated Electrically Operated Cradle w/Rear Horizontal Terminals E1B-A08 E1N-A08 E2N-A08 E2S-A08 E2H-A08 E3S-A08 E3H-A08 E3V-A08 E3X-A08 800 800 800 800 800 800 800 800 800 42 50 50 65 85 65 85 125 200 $ 7,383 7,754 8,529 9,038 9,564 9,408 9,792 10,404 12,240 $ 9,744 10,115 10,890 11,399 11,925 11,769 12,153 12,765 14,601 $ 2,281 2,281 2,400 2,400 2,400 2,925 2,925 2,925 4,109 $ 644 644 690 690 690 790 790 790 790 E1B-A12 E1N-A12 E2N-A12 E2S-A12 E2H-A12 E3S-A12 E3H-A12 E3V-A12 E3X-A12 1200 1200 1200 1200 1200 1200 1200 1200 1200 42 50 50 65 85 65 85 125 200 8,375 8,690 8,814 9,242 9,687 9,520 9,633 10,596 12,467 10,736 11,051 11,175 11,603 12,048 11,581 11,994 12,957 14,828 2,281 2,281 2,400 2,400 2,400 2,925 2,925 2,925 4,109 644 644 690 690 690 790 790 790 790 E2B-A16 E2N-A16 E2S-A16 E2H-A16 E3S-A16 E3H-A16 E3V-A16 E3X-A16 1600 1600 1600 1600 1600 1600 1600 1600 42 50 65 85 65 85 125 200 9,320 10,483 11,506 11,726 10,931 11,445 12,590 14,812 11,681 12,844 13,867 14,087 13,292 13,806 14,951 17,173 2,400 2,400 2,400 2,400 2,925 2,925 2,925 4,109 690 690 690 690 790 790 790 790 E3N-A20 E3S-A20 E3H-A20 E3V-A20 E3X-A20 2000 2000 2000 2000 2000 50 65 85 125 200 11,386 12,700 14,262 15,688 18,456 13,747 15,061 16,623 18,049 20,817 2,925 2,925 2,925 2,925 4,109 790 790 790 790 790 E3N-A25 E3S-A25 E3H-A25 E3V-A25 2500 2500 2500 2500 50 65 85 125 17,767 20,315 22,622 24,884 20,128 22,676 24,983 27,245 2,925 2,925 2,925 2,925 790 790 790 790 E3S-A32 E3H-A32 E3V-A32 E4S-A32 E4H-A32 E4V-A32 E4L-A32 3200 3200 3200 3200 3200 3200 3200 65 85 125 65 85 100 150 25,310 26,009 27,177 23,800 24,447 25,863 31,205 27,671 28,370 29,538 26,161 26,808 28,224 33,566 7,259 7,259 7,259 6,259 6,259 6,259 6,259 6 Vertical Terminals are standard 1,664 1,664 1,664 1,664 E4S-A36 E4H-A36 E4V-A36 E4L-A36 3600 3600 3600 3600 65 85 100 150 26,863 30,865 31,948 42,215 29,224 33,226 34,309 44,576 6,259 6,259 6,259 6,259 1,664 1,664 1,664 1,664 E6H-A40 E6V-A40 E6L-A40 E6X-A40 4000 4000 4000 4000 85 125 150 200 34,676 46,570 51,407 54,113 37,037 48,931 53,768 56,474 7,398 7,398 7,398 7,398 2,783 2,783 2,783 2,783 E6H-A50 E6V-A50 E6L-A50 E6X-A50 5000 5000 5000 5000 85 125 150 200 46,402 57,078 59,375 62,500 48,763 59,439 61,736 64,861 7,398 7,398 7,398 7,398 2,783 2,783 2,783 2,783 Standard features – electrically operated breaker Moving part Standard features – electrically operated breaker Fixed part • • • • • • • • • • • • • • • • • • • PR121 trip unit with LI protection feature Spring charging motor Shunt trip Closing coil Manual mechanical close and open pushbuttons CB open/closed mechanical indicator Spring charged/discharged mechanical indicator 2NO & 2NC auxiliary contacts for open-closed position indication Lifting plates Current transformers Racking device with closed door Circuit breaker racking position indicator Sliding contacts Fail safe device (not available with YU) Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Set of Three Vertical Terminals 16 Safety shutters Rear horizontal terminals except where noted Sliding contacts Anti-insertion lock Ground connection Discount schedule ED1 - ED6 16.13 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow Withdrawable breakers, 4 pole UL P Withdrawable breakers E1B-A08 E1N-A08 E2N-A08 E2S-A08 E2H-A08 E3S-A08 E3H-A08 E3V-A08 E3X-A08 800 800 800 800 800 800 800 800 800 Interrupting Ratings kA, 480V 42 50 50 65 85 65 85 125 200 E1B-A12 E1N-A12 E2N-A12 E2S-A12 E2H-A12 E3S-A12 E3H-A12 E3V-A12 E3X-A12 1200 1200 1200 1200 1200 1200 1200 1200 1200 E2B-A16 E2N-A16 E2S-A16 E2H-A16 E3S-A16 E3H-A16 E3V-A16 E3X-A16 UL 16 Frame Amps Manually Operated Electrically Operated Cradle w/Rear Horizontal Terminals $ 3,079 3,079 3,240 3,240 3,240 3,949 3,949 3,949 4,109 Set of Four Vertical Terminals $ 870 870 935 935 935 1,067 1,067 1,067 1,067 $ 9,967 10,513 11,107 11,306 12,508 11,107 12,287 13,645 16,524 $ 12,328 12,874 13,468 13,667 14,869 13,468 14,648 16,006 18,885 42 50 50 65 85 65 85 125 200 11,306 11,262 11,899 12,596 12,846 12,447 13,005 14,305 16,830 13,667 13,623 14,260 14,957 15,207 14,808 15,366 16,666 19,191 3,079 3,079 3,240 3,240 3,240 3,949 3,949 3,949 4,109 870 870 935 935 935 1,067 1,067 1,067 1,067 1600 1600 1600 1600 1600 1600 1600 1600 42 50 65 85 65 85 125 200 12,582 14,152 14,515 14,800 14,757 15,451 16,996 19,996 14,943 16,513 16,876 17,161 17,118 17,812 19,357 22,357 3,240 3,240 3,240 3,240 3,949 3,949 3,949 4,109 935 935 935 935 1,067 1,067 1,067 1,067 E3N-A20 E3S-A20 E3H-A20 E3V-A20 E3X-A20 2000 2000 2000 2000 2000 50 65 85 125 200 15,371 17,145 19,254 21,179 24,916 17,732 19,506 21,615 23,540 27,277 3,949 3,949 3,949 3,949 4,109 1,067 1,067 1,067 1,067 1,067 E3N-A25 E3S-A25 E3H-A25 E3V-A25 2500 2500 2500 2500 50 65 85 125 23,985 27,425 30,540 33,594 26,346 29,786 32,901 35,955 3,949 3,949 3,949 3,949 1,067 1,067 1,067 1,067 E3S-A32 E3H-A32 E3V-A32 E4S-A32 E4H-A32 E4H-A/f32 1 E4V-A32 E4L-A32 3200 3200 3200 3200 3200 3200 3200 3200 65 85 125 65 85 85 100 150 24,789 33,369 33,884 32,130 33,003 34,067 34,915 40,123 27,150 35,730 36,245 34,491 35,364 36,428 37,276 42,484 9,679 9,679 9,679 8,450 8,450 9,657 8,450 8,450 E4S-A36 E4H-A36 E4H-A/f36 1 E4V-A36 E4L-A36 3600 3600 3600 3600 3600 65 85 85 100 150 36,265 41,668 43,659 43,130 48,173 38,626 44,029 46,020 45,491 50,534 8,450 8,450 9,657 8,450 8,450 2,250 2,250 2,572 2,250 2,250 E6H-A40 E6H-A/f40 1 E6V-A40 E6L-A40 E6X-A40 E6X-A/f40 4000 4000 4000 4000 4000 4000 85 85 125 150 200 200 46,813 53,123 62,870 66,386 73,053 83,489 49,174 55,484 65,231 68,747 75,414 85,850 9,987 11,414 9,987 9,987 9,987 11,414 3,757 4,294 3,757 3,757 3,757 4,294 E6H-A50 E6H-A/f50 1 E6V-A50 E6L-A50 E6X-A50 E6X-A/f50 5000 5000 5000 5000 5000 5000 85 85 125 150 200 200 63,643 68,799 77,055 80,156 84,375 96,429 65,004 71,160 79,416 82,517 86,736 98,790 9,987 11,414 9,987 9,987 9,987 11,414 3,757 4,294 3,757 3,757 3,757 4,294 Standard features – electrically operated breaker Moving part Standard features – electrically operated breaker Fixed part • • • • • • • • • • • • • • • • • • • PR121 trip unit with LI protection feature Spring charging motor Shunt trip Closing coil Manual mechanical close and open pushbuttons CB open/closed mechanical indicator Spring charged/discharged mechanical indicator 2NO & 2NC auxiliary contacts for open-closed position indication Lifting plates Current transformers Racking device with closed door Circuit breaker racking position indicator Sliding contacts Fail safe device (not available with YU) 16.14 LV040 [1SXU200040C0202] - 10/07 8 Vertical Terminals are standard 2,250 2,250 2,572 2,250 2,250 Safety shutters Rear horizontal terminals Sliding contacts Anti-insertion lock Ground connection Neutral pole rating • E1 – E3 = 100% rating • E4 – E6 = 50% rating 1 Special 100% neutral pole rating. Discount schedule ED1 - ED6 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 Po we Em r b ax re ak e Non-automatic switches Fixed switches (without trip unit & c.t.s.), 3 pole UL rs Fixed switches Manually Operated Electrically Operated Set of Three Vertical Terminals UL Frame Amps Rated Short Time Current, kA E1B-A/MS-08 E1N-A/MS-08 E2N-A/MS-08 E2S-A/MS-08 E3S-A/MS-08 E3V-A/MS-08 800 800 800 800 800 800 42 50 50 65 65 85 $ 5,086 5,334 7,230 7,498 7,053 9,050 $ 7,447 7,695 9,591 9,859 9,414 11,411 $ 644 644 690 690 790 790 E1B-A/MS-12 E1N-A/MS-12 E2N-A/MS-12 E2S-A/MS-12 E3S-A/MS-12 E3V-A/MS-12 1200 1200 1200 1200 1200 1200 42 50 50 65 65 85 5,592 5,627 6,090 7,348 6,944 9,407 7,953 7,988 8,451 9,709 9,305 11,768 644 644 690 690 790 790 E2B-A/MS-16 E2N-A/MS-16 E2S-A/MS-16 E3S-A/MS-16 E3V-A/MS-16 1600 1600 1600 1600 1600 42 50 65 65 85 6,142 7,353 8,550 7,961 10,731 8,503 9,714 10,911 10,322 13,092 690 690 690 790 790 E3N-A/MS-20 E3S-A/MS-20 E3V-A/MS-20 2000 2000 2000 50 65 85 8,196 9,217 14,564 10,557 11,578 16,925 790 790 790 E3N-A/MS-25 E3S-A/MS-25 E3V-A/MS-25 2500 2500 2500 50 65 85 12,942 14,615 17,658 15,303 16,976 20,019 790 790 790 E3S-A/MS-32 E3V-A/MS-32 E4S-A/MS-32 E4H-A/MS-32 E4V-A/MS-32 E4S-A/MS-36 E4H-A/MS-36 E4V-A/MS-36 3200 3200 3200 3200 3200 3600 3600 3600 65 85 65 85 100 65 85 100 20,091 21,148 18,733 19,197 24,305 21,570 24,933 29,258 22,452 23,509 21,094 21,558 26,666 23,931 27,294 31,619 6 Vertical Terminals are standard E6H-A/MS-40 4000 100 28,946 31,307 2,783 E6H-A/MS-50 5000 100 40,639 43,000 2,783 1,664 1,664 1,664 1,664 1,664 1,664 Standard features – manually operated UL switch • • • • • • Rear horizontal terminals except where noted Manual mechanical close and open pushbuttons CB open/closed mechanical indicator Spring charged/discharged mechanical indicator Lifting plates Terminal box Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 Discount schedule ED1 - ED6 16.15 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Non-automatic switches Fixed switches (without trip unit & c.t.s.), 4 pole UL Fixed switches Electrically Operated Set of Four Vertical Terminals $ 6,866 7,108 9,634 9,991 9,169 12,059 $ 9,227 9,469 11,995 12,352 11,530 14,420 $ 870 870 935 935 1,067 1,067 42 50 50 65 65 85 7,549 7,648 8,222 10,349 9,374 12,229 9,910 10,009 10,583 12,710 11,735 14,590 870 870 935 935 1,067 1,067 1600 1600 1600 1600 1600 42 50 65 65 85 8,282 9,927 12,042 10,747 13,950 10,653 12,288 14,403 13,108 16,311 935 935 935 1,067 1,067 E3N-A/MS-20 E3S-A/MS-20 E3V-A/MS-20 2000 2000 2000 50 65 85 11,065 12,443 18,933 13,426 14,804 21,294 1,067 1,067 1,067 E3N-A/MS-25 E3S-A/MS-25 E3V-A/MS-25 2500 2500 2500 50 65 85 17,472 19,730 23,452 19,833 22,091 25,813 1,067 1,067 1,067 E3S-A/MS-32 E3V-A/MS-32 E4S-A/MS-32 E4H-A/MS-32 E4H-A/f/MS-32 1 E4V-A/MS-32 3200 3200 3200 3200 3200 3200 65 85 65 85 85 100 26,118 27,492 25,290 25,916 27,899 31,597 28,479 29,853 27,651 28,277 30,260 33,958 8 Vertical Termianls are standard 2,250 2,250 2,572 2,250 E4S-A/MS-36 E4H-A/MS-36 E4H-A/f/MS-36 1 E4V-A/MS-36 3600 3600 3600 3600 65 85 85 100 29,120 33,660 36,372 38,035 31,481 36,021 38,733 40,396 2,250 2,250 2,572 2,250 E6H-A/MS-40 E6H-A/f/MS-40 1 4000 4000 100 100 39,077 42,260 41,438 44,621 3,757 4,294 E6H-A/MS-50 E6H-A/f/MS-50 1 5000 5000 100 100 54,863 59,535 57,224 61,896 3,757 4,294 UL Frame Amps Rated Short Time Current, kA E1B-A/MS-08 E1N-A/MS-08 E2N-A/MS-08 E2S-A/MS-08 E3S-A/MS-08 E3V-A/MS-08 800 800 800 800 800 800 42 50 50 65 65 85 E1B-A/MS-12 E1N-A/MS-12 E2N-A/MS-12 E2S-A/MS-12 E3S-A/MS-12 E3V-A/MS-12 1200 1200 1200 1200 1200 1200 E2B-A/MS-16 E2N-A/MS-16 E2S-A/MS-16 E3S-A/MS-16 E3V-A/MS-16 Standard features – manually operated UL switch 16 • • • • • • Rear horizontal terminals except where noted Manual mechanical close and open pushbuttons CB open/closed mechanical indicator Spring charged/discharged mechanical indicator Lifting plates Terminal box Manually Operated Neutral pole rating • E1 – E3 = 100% rating • E4 – E6 = 50% rating 1 Special 100% neutral pole rating. 16.16 LV040 [1SXU200040C0202] - 10/07 Discount schedule ED1 - ED6 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 P ow Em Non-automatic switches er ax Withdrawable switches (without trip unit & c.t.s.), 3 pole break er s UL Withdrawable switches UL Frame Amps Rated Short Time Current, kA Manually Operated Electrically Operated Cradle w/Rear Horizontal Terminals Set of Three Vertical Terminals E1B-A/MS-08 E1N-A/MS-08 E2N-A/MS-08 E2S-A/MS-08 E3S-A/MS-08 E3V-A/MS-08 800 800 800 800 800 800 42 50 50 65 65 85 $ 5,654 6,355 7,407 7,560 7,931 9,360 $ 8,015 8,716 9,768 9,921 10,292 11,721 $ 2,281 2,281 2,281 2,281 2,925 2,925 $ 644 644 690 690 790 790 E1B-A/MS-12 E1N-A/MS-12 E2N-A/MS-12 E2S-A/MS-12 E3S-A/MS-12 E3V-A/MS-12 1200 1200 1200 1200 1200 1200 42 50 50 65 65 85 6,646 6,920 7,085 8,149 7,384 10,064 9,007 9,281 9,446 10,510 9,745 12,425 2,281 2,281 2,400 2,400 2,925 2,925 644 644 690 690 790 790 E2B-A/MS-16 E2N-A/MS-16 E2S-A/MS-16 E3S-A/MS-16 E3V-A/MS-16 1600 1600 1600 1600 1600 42 50 65 65 85 7,591 8,754 10,029 9,095 11,585 9,952 11,115 12,390 11,456 13,946 2,400 2,400 2,400 2,925 2,925 690 690 690 790 790 E3N-A/MS-20 E3S-A/MS-20 E3V-A/MS-20 2000 2000 2000 50 65 85 9,550 10,864 14,800 11,911 13,225 17,161 2,925 2,925 2,925 790 790 790 E3N-A/MS-25 E3S-A/MS-25 E3V-A/MS-25 2500 2500 2500 50 65 85 15,931 18,479 22,505 18,292 20,840 24,866 2,925 2,925 2,925 790 790 790 E3S-A/MS-32 E3V-A/MS-32 E4S-A/MS-32 E4H-A/MS-32 E4V-A/MS-32 3200 3200 3200 3200 3200 65 85 65 85 100 23,833 25,327 21,431 22,078 24,831 26,194 27,688 23,792 24,439 27,192 7,257 7,257 6,259 6,259 6,259 E4S-A/MS-36 E4H-A/MS-36 E4V-A/MS-36 3600 3600 3600 65 85 100 24,494 28,496 32,148 26,855 30,857 34,509 6,259 6,259 6,259 1,664 1,664 1,664 E6H-A/MS-40 4000 100 32,094 34,455 7,398 2,783 E6H-A/MS-50 5000 100 43,820 46,181 7,398 2,783 6 Vertical Terminals are standard 1,664 1,664 1,664 Standard features – manually operated switch Moving part Standard features – manually operated switch Fixed part • • • • • • • • • • • • • Manual mechanical close and open pushbuttons Circuit breaker open/closed mechanical indicator Spring charged/discharged mechanical indicator Lifting plates Racking device with closed door Circuit breaker racking position indicator Sliding contacts Fail-safe device (not available with YU) Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Safety shutters Rear horizontal terminals except where noted Sliding contacts Anti-insertion lock Ground connection Discount schedule ED1 - ED6 16 16.17 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Non-automatic switches Withdrawable switches (without trip unit & c.t.s.), 4 pole UL Withdrawable switches 16 UL Frame Amps Rated Short Time Current, kA Manually Operated Electrically Operated Cradle w/Rear Horizontal Terminals Set of Four Vertical Terminals E1B-A/MS-08 E1N-A/MS-08 E2N-A/MS-08 E2S-A/MS-08 E3S-A/MS-08 E3V-A/MS-08 800 800 800 800 800 800 42 50 50 65 65 85 $ 7,633 7,886 9,244 9,828 9,898 11,681 $ 9,994 10,247 11,605 12,189 12,259 14,042 $ 3,079 3,079 3,240 3,240 3,949 3,949 $ 870 870 935 935 1,066 1,066 E1B-A/MS-12 E1N-A/MS-12 E2N-A/MS-12 E2S-A/MS-12 E3S-A/MS-12 E3V-A/MS-12 1200 1200 1200 1200 1200 1200 42 50 50 65 65 85 8,972 8,996 9,565 10,594 9,968 13,084 11,333 11,357 11,926 12,955 12,329 15,445 3,079 3,079 3,240 3,240 3,949 3,949 870 870 935 935 1,066 1,066 E2B-A/MS-16 E2N-A/MS-16 E2S-A/MS-16 E3S-A/MS-16 E3V-A/MS-16 1600 1600 1600 1600 1600 42 50 65 65 85 10,248 11,818 12,516 12,278 15,060 12,609 14,179 14,877 14,639 17,421 3,240 3,240 3,240 3,949 3,949 935 935 897 1,066 1,066 E3N-A/MS-20 E3S-A/MS-20 E3V-A/MS-20 2000 2000 2000 50 65 85 12,893 14,666 19,240 15,254 17,027 21,601 3,949 3,949 3,949 1,066 1,066 1,066 E3N-A/MS-25 E3S-A/MS-25 E3V-A/MS-25 2500 2500 2500 50 65 85 21,507 24,947 29,257 23,868 27,308 31,618 3,949 3,949 3,949 1,066 1,066 1,066 E3S-A/MS-32 E3V-A/MS-32 E4S-A/MS-32 E4H-A/MS-32 E4H-A/f/MS-32 1 E4V-A/MS-32 3200 3200 3200 3200 3200 3200 65 85 65 85 85 100 28,599 30,181 28,932 29,805 31,237 32,280 30,960 32,542 31,293 32,166 33,598 34,641 9,679 9,679 8,450 8,450 9,657 8,450 E4S-A/MS-36 E4H-A/MS-36 E4H-A/f/MS-36 1 E4V-A/MS-36 3600 3600 3600 3600 65 85 85 100 33,067 38,470 43,786 45,592 35,428 40,831 46,147 47,953 8,450 8,450 9,657 8,450 2,250 2,250 2,572 2,250 E6H-A/MS-40 E6H-A/f/MS-40 1 4000 4000 100 100 43,327 46,217 45,688 48,578 9,987 11,414 3,757 4,294 E6H-A/MS-50 E6H-A/f/MS-50 1 5000 5000 100 100 59,157 63,669 61,518 66,030 9,987 11,414 3,757 4,294 8 Vertical Terminals are standard 2,250 2,250 2,572 2,250 Standard features – manually operated switch Moving part Standard features – manually operated switches Fixed part • • • • • • • • • • • • • Manual mechanical close and open pushbuttons Circuit breaker open/closed mechanical indicator Spring charged/discharged mechanical indicator Lifting plates Racking device with closed door Circuit breaker racking position indicator Sliding contacts Fail-safe device (not available with YU) Safety shutters Rear horizontal terminals except where noted Sliding contacts Anti-insertion lock Ground connection Neutral pole rating • E1 – E3 = 100% rating • E4 – E6 = 50% rating 1 Special 100% neutral pole rating. 16.18 LV040 [1SXU200040C0202] - 10/07 Discount schedule ED1 - ED6 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 Po Circuit breakers in accordance with IEC 6097-2 we Em r b ax re ak e rs E1 Poles 4p c.-b neutral current-carring capacity Iu (40 °C) Ue Icu Ics Icw (220...415V) (220...415V) (1s) (3s) E2 E1B Automatic circuit-breakers [No.] [%Iu] [A] 800 1000 1250 1600 [V~] [kA] [kA] [kA] [kA] E1N 3-4 100 690 42 42 42 36 E2B E2S E2L E3N E3S 3-4 100 800 690 50 50 50 36 E3 E2N 690 42 42 42 42 690 65 65 55 42 690 85 85 65 42 690 130 130 10 — 690 65 65 65 65 690 75 75 75 75 E3H 3-4 100 E3V E3L 80012501600200025003200 690 100 85 75 65 690 130 100 85 65 690 130 130 15 — Automatic circuit-breakers with full-size neutral conductor Poles 4p c.-b neutral current-carring capacity Iu (40 °C) Ue Icu (220...415V) Ics (220...415V) Icw (1s) (3s) [No.] [%Iu] [A] [V~] [kA] [kA] [kA] [kA] Switch-disconnectors Standard version Standard version Standard version E1B/MS E1N/MS E2B/MS E2N/MS E2S/MS E3N/MS E3S/MS E3V/MS [No.] [A] 3-4 800100012501600 3-4 800- 3-4 3-4 3-4 3-4 3-4 [V~] [kA] [kA] [kA] 690 42 36 88.2 690 50 36 105 690 42 42 88.2 690 42 42 88.2 690 65 42 143 690 65 65 143 690 75 65 165 3-4 80012501600200025003200 690 85 65 286 Automatic circuit-breakers for applications up to 1150VAC E2B/E E2N/E E3H/E Poles Iu Ue Icu Ics Icw 3-4 3-4 3-4 1150 20 20 20 1150 30 30 30 1150 30 1 30 1 30 1 Poles Iu (40 °C) Ue Icw Icm (1s) (3s) (220...440V) (40 °C) (1150V) (1150V) (1s) [No.] [A] [V~] [kA] [kA] [kA] E2B/E MS E2N/E MS Switch-disconnectors for applications up to 1150VAC Poles Iu Ue Icu Ics (40 °C) (1s) (1000V) [No.] [A] [V~] [kA] [kA] Switch-disconnectors for applications up to 1000VDC Poles Iu UE (40 °C) Icw Icm (1s) (750V) (1000V) Iu (40 °C) [A] Earthing switch with makeing capacity Iu (40 °C) [A] Earthing truck Iu (40 °C) 3-4 3-4 1150 20 40 1150 30 63 1150 50 105 E2N/E MS E3H/E MS 3-4 3-4 750 (3p)1000(4p) 25 52.5 52.5 750 (3p)1000(4p) 40 105 105 E1 CS E2 CS E3 CS 1250 2000 3200 E1 MTP E2 MTP E3 MTP E1B/E MS [No.] 3-4 [A] 800-1250 [V~] 750 (3p)1000(4p) [kA] 20 [kA] 42 [kA] 42 Sectionalizing truck [A] E3H/E MS 3-4 1250 2000 3200 E1 MT E2 MT E3 MT 1250 2000 3200 16 1 The performance at 1000V is 50kA. Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.19 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow Circuit breakers in accordance with IEC 6097-2 P E4 E4S Automatic circuit-breakers Poles [No.] 4p c.-b neutral current-carring capacity Iu Ue E6H E6V 3 -4 50 50 [A] 4000 3200-4000 3200-4000 4000-5000-6300 [V~] 690 690 690 690 690 Icu (220...415V) [kA] 75 100 150 100 150 Ics (220...415V) [kA] 75 100 150 100 125 Icw (1s) [kA] 75 100 100 100 100 (3s) [kA] 75 75 75 85 85 E4S/f E4H/f Automatic circuit-breakers with full-size neutral conductor E6H/f Poles [No.] 4 4 4 4p c.-b neutral current-carring capacity [%Iu] 100 100 100 Iu (40 °C) Ue [A] 4000 3200-4000 4000-5000-6300 [V~] 690 690 690 Icu (220...415V) [kA] 80 100 100 Ics (220...415V) [kA] 80 100 100 Icw (1s) [kA] 80 85 100 (3s) [kA] 75 75 E4S/MS E4H/MS E4H/fMS E6H/MS [No.] 3 -4 3 -4 3 -4 3 -4 3 -4 [A] 4000 3200-4000 3200-4000 4000-5000-6300 4000-5000-6300 Switch-disconnectors Poles Iu (40 °C) Ue 100 E6H/fMS [V~] 690 690 690 690 690 Icw (1s) [kA] 75 100 85 100 100 (3s) [kA] 75 75 75 85 85 Icm (220...440V) [kA] 165 220 220 220 220 Automatic circuit-breakers for applications up to 1150VAC Poles Iu E4H/E [No.] (40 °C) Ue E6H/E 3 -4 3-4 [A] 3200-4000 4000-5000-6300 [V~] 1150 1150 Icu (1150V) [kA] 65 65 Ics (1150V) [kA] 65 65 Icw (1s) [kA] 65 65 E4H/E MS E6H/E MS 3 -4 3-4 Switch-disconnectors for applications up to 1150VAC Poles Iu 16 E6 E4V 3 -4 [%Iu] (40 °C) E4H [No.] (40 °C) Ue [A] 3200-4000 4000-5000 [V~] 1150 1150 Icu (1s) [kA] 65 65 Ics (1000V) [kA] 143 143 E4H/E MS E6H/E MS Switch-disconnectors for applications up to 1000VDC Poles Iu [No.] (40 °C) UE 3 -4 3-4 [A] 3200-4000 4000-5000-6300 750(3p) - 1000(4p) [V~] 750(3p) - 1000(4p) Icw (1s) [kA] 65 65 Icm (750V) [kA] 143 143 (1000V) [kA] 143 143 Sectionalizing truck Iu (40 °C) E4 CS [A] Earthing switch with makeing capacity Iu (40 °C) [A] Earthing truck Iu (40 °C) 16.20 LV040 [1SXU200040C0202] - 10/07 [A] E3H/E MS E6 CS 4000 6300 E4 MTP E6 MTP 4000 6300 E4 MT E6 MT 4000 6300 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 Po we Em r b ax re ak e Fixed breakers, 3 poles IEC rs Fixed breakers IEC Frame Amps Interrupting Ratings kA, 415V Manually Operated Electrically Operated Set of Three Vertical Terminals Set of Three Front Terminals E1B08 E1N08 E2S08 E3H08 E3V08 800 800 800 800 800 42 50 85 100 130 $ 6,027 6,199 6,968 7,709 7,825 $ 8,388 8,560 9,329 10,070 10,186 $ 644 644 690 790 790 $ 367 367 888 1,232 1,232 E1B10 E1N10 E2N10 E2S10 E3S10 E3H10 1000 1000 1000 1000 1000 1000 42 50 65 85 75 100 6,289 6,352 7,078 7,184 7,947 8,190 8,650 8,713 9,439 9,545 10,308 10,551 644 644 690 690 790 790 367 367 888 888 1,232 1,232 E1B12 E1N12 E2N12 E2S12 E2L12 E3S12 E3H12 E3V12 1250 1250 1250 1250 1250 1250 1250 1250 42 50 65 85 130 75 100 130 6,656 6,839 7,314 7,854 9,368 7,808 8,036 9,453 9,017 9,200 9,675 10,215 11,729 10,169 10,397 11,814 644 644 690 690 690 790 790 790 367 367 888 888 888 1,232 1,232 1,232 E1B16 E1N16 E2B16 E2N16 E2S16 E2L16 E3S16 E3H16 E3V16 1600 1600 1600 1600 1600 1600 1600 1600 1600 42 50 42 65 85 130 75 100 130 6,940 7,010 7,293 8,014 8,689 11,189 8,700 9,232 11,265 9,301 9,371 9,654 10,375 11,050 13,550 11,061 11,593 13,626 644 644 690 690 690 690 790 790 790 367 367 888 888 888 888 1,232 1,232 1,232 E2B20 E2N20 E2S20 E3S20 E3H20 E3V20 E3L20 2000 2000 2000 2000 2000 2000 2000 42 65 85 75 100 130 130 8,509 9,024 9,784 9,817 11,762 13,157 13,425 10,870 11,385 12,145 12,178 14,123 15,518 15,786 690 690 690 790 790 790 790 888 888 888 1,232 1,232 1,232 1,232 E3N25 E3S25 E3H25 E3V25 E3L25 2500 2500 2500 2500 2500 65 75 100 130 130 13,870 15,242 16,948 18,010 19,454 16,231 17,603 19,309 20,371 21,815 790 790 790 790 790 1,232 1,232 1,232 1,232 1,232 E3N32 E3S32 E3H32 E3V32 E4H32 E4V32 E6V32 3200 3200 3200 3200 3200 3200 3200 65 75 100 130 100 150 150 17,963 18,662 20,217 21,711 22,085 28,163 36,328 20,324 21,023 22,578 24,072 24,446 30,524 38,689 790 790 790 790 1,664 2,783 2,783 1,232 1,232 1,232 1,232 1,696 2,464 2,464 E4S40 E4H40 E4V40 E6H40 E6V40 4000 4000 4000 4000 4000 75 85 100 100 150 26,873 30,645 34,445 38,497 42,739 29,234 33,006 36,806 40,858 45,100 1,664 1,664 1,664 2,783 2,783 1,696 1,696 1,696 2,464 2,464 E6H50 E6V50 5000 5000 100 150 42,047 50,281 44,408 52,642 2,783 2,783 2,464 2,464 E6H63 E6V63 6300 6300 100 150 50,456 60,337 52,817 63,698 2,783 2,783 2,464 2,464 16 Standard features – manually operated breaker Fixed breaker • • • • • • • • • Rear horizontal terminals PR121 trip unit with LI protection functions Manual mechanical close and open pushbuttons CB open/closed mechanical indicator Spring charged/discharged mechanical indicator 2NO & 2NC auxiliary contacts for open-closed position indication Lifting plates Current transformers Terminal box Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Discount schedule ED1 - ED6 16.21 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow Fixed breakers, 4 poles IEC P Fixed breakers 16 IEC Frame Amps Interrupting Ratings kA, 415V Manually Operated Electrically Operated E1B08 E1N08 E2S08 E3H08 E3V08 800 800 800 800 800 42 50 85 100 130 $ 7,475 7,688 8,960 9,213 10,353 $ 9,836 10,049 11,321 11,574 12,714 $ 837 837 897 1,027 1,027 $ 489 489 1,183 1,643 1,643 E1B10 E1N10 E2N10 E2S10 E3S10 E3H10 1000 1000 1000 1000 1000 1000 42 50 65 85 75 100 7,800 8,053 8,512 8,959 9,069 9,452 10,161 10,414 10,873 11,320 11,430 11,813 837 837 897 897 1,027 1,027 489 489 1,183 1,183 1,643 1,643 E1B12 E1N12 E2N12 E2S12 E2L12 E3S12 E3H12 E3V12 1250 1250 1250 1250 1250 1250 1250 1250 42 50 65 85 130 75 100 130 8,293 8,520 9,148 9,446 12,725 9,306 9,591 11,389 10,654 10,881 11,509 11,807 15,086 11,667 11,952 13,750 837 837 897 897 897 1,027 1,027 1,027 489 489 1,183 1,183 1,183 1,643 1,643 1,643 E1B16 E1N16 E2B16 E2N16 E2S16 E2L16 E3S16 E3H16 E3V16 1600 1600 1600 1600 1600 1600 1600 1600 1600 42 50 42 65 85 130 75 100 130 8,647 8,733 9,121 10,059 10,906 13,666 10,413 10,550 14,162 11,008 11,094 11,482 12,420 13,267 16,849 12,774 12,911 16,523 837 837 897 897 897 897 1,027 1,027 1,027 489 489 1,183 1,183 1,183 1,183 1,643 1,643 1,643 E2B20 E2N20 E2S20 E3S20 E3H20 E3V20 E3L20 2000 2000 2000 2000 2000 2000 2000 42 65 85 75 100 130 130 10,701 11,371 12,329 11,795 13,621 16,872 17,093 13,062 13,732 14,690 14,156 15,982 19,233 19,454 897 897 897 1,027 1,027 1,027 1,027 1,183 1,183 1,183 1,643 1,643 1,643 1,643 E3N25 E3S25 E3H25 E3V25 E3L25 2500 2500 2500 2500 2500 65 75 100 130 130 17,671 19,454 21,672 23,301 24,930 20,032 21,815 24,033 25,662 27,291 1,027 1,027 1,027 1,027 1,027 1,643 1,643 1,643 1,643 1,643 E3N32 E3S32 E3H32 E3V32 E4H32 E4H/f32 E4V32 E6V32 3200 3200 3200 3200 3200 3200 3200 3200 65 75 100 130 100 100 150 150 22,992 23,900 27,307 30,714 28,351 29,920 36,153 45,410 25,353 26,261 29,668 33,075 30,712 32,281 38,514 47,771 1,027 1,027 1,027 1,027 2,163 2,472 2,163 3,618 1,643 1,643 1,643 1,643 2,260 2,583 2,260 3,286 E4S40 E4H40 E4H/f40 E4V40 E6H40 E6H/f40 E6V40 4000 4000 4000 4000 4000 4000 4000 75 85 85 100 100 100 150 34,610 39,516 41,652 42,923 48,122 50,528 53,424 36,971 41,877 44,013 45,284 50,483 52,889 55,785 2,163 2,163 2,472 2,163 3,618 4,135 3,618 2,260 2,260 2,583 2,260 3,286 3,756 3,286 E6H50 E6H/f50 E6V50 5000 5000 5000 100 100 150 52,558 56,142 62,852 54,919 58,503 65,213 3,618 4,135 3,618 3,286 3,756 3,286 E6H63 E6H/f63 E6V63 6300 6300 6300 100 100 150 63,070 67,370 75,422 65,431 69,731 77,783 3,818 4,135 3,618 3,286 3,756 3,286 Standard features – manually operated breaker Fixed breaker • • • • • • Rear horizontal terminals PR121 trip unit with LI protection functions Manual mechanical close and open pushbuttons Manual mechanical close and open pushbuttons CB open/closed mechanical indicator Spring charged/discharged mechanical indicator 1 Consult factory for special 100% neutral pole rating. 16.22 LV040 [1SXU200040C0202] - 10/07 • • • • Set of Four Vertical Terminals Set of Four Front Terminals 2NO & 2NC auxiliary contacts for open-closed position indication Lifting plates Current transformers Terminal box Neutral pole rating • E1 – E3 = 100% rating • E4 – E6 = 50% rating Discount schedule ED1 - ED6 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 Po we Em r b ax re ak e Withdrawable breakers, 3 poles IEC rs Withdrawable breakers IEC Frame Amps Interrupting Ratings kA, 415V Manually Operated Electrically Operated Cradle w/Rear Horizontal / Flat Terminals Set of Three Vertical Terminals E1B08 E1N08 E2S08 E3H08 E3V08 800 800 800 800 800 42 50 85 100 130 $ 6,501 6,877 7,883 8,125 8,246 $ 8,862 9,238 10,244 10,486 10,607 $ 2,281 2,281 2,400 2,925 2,925 $ 644 644 690 790 790 $ 367 367 888 1,232 1,232 E1B10 E1N10 E2N10 E2S10 E3S10 E3H10 1000 1000 1000 1000 1000 1000 42 50 65 85 75 100 7,337 7,684 8,007 8,127 8,585 8,749 9,698 10,045 10,368 10,488 10,946 11,110 2,281 2,281 2,400 2,400 2,925 2,925 644 644 690 690 790 790 367 367 888 888 1,232 1,232 E1B12 E1N12 E2N12 E2S12 E2L12 E3S12 E3H12 E3V12 1250 1250 1250 1250 1250 1250 1250 1250 42 50 65 85 130 75 100 130 7,757 8,101 8,626 9,151 12,180 8,760 8,897 9,363 10,118 10,462 10,987 11,512 14,541 11,121 11,258 11,724 2,281 2,281 2,400 2,400 2,400 2,925 2,925 2,925 644 644 690 690 690 790 790 790 367 367 888 888 888 1,232 1,232 1,232 E1B16 E1N16 E2B16 E2N16 E2S16 E2L16 E3S16 E3H16 E3V16 1600 1600 1600 1600 1600 1600 1600 1600 1600 42 50 42 65 85 130 75 100 130 8,222 8,304 9,097 10,234 11,371 14,704 10,674 11,100 15,126 10,583 10,665 11,458 12,595 13,732 18,281 13,035 13,461 17,487 2,281 2,281 2,400 2,400 2,400 2,400 2,925 2,925 2,925 644 644 690 690 690 690 790 790 790 367 367 888 888 888 888 1,232 1,232 1,232 E2B20 E2N20 E2S20 E3S20 E3H20 E3V20 E3L20 2000 2000 2000 2000 2000 2000 2000 42 65 85 75 100 130 130 10,987 11,182 11,377 11,361 13,256 13,864 17,817 13,348 13,543 13,738 13,722 15,617 16,225 20,178 2,400 2,400 2,400 2,925 2,925 2,925 2,925 690 690 690 790 790 790 790 888 888 888 1,232 1,232 1,232 1,232 E3N25 E3S25 E3H25 E3V25 E3L25 2500 2500 2500 2500 2500 65 75 100 130 130 15,220 17,896 19,528 21,210 22,892 17,581 20,257 21,889 23,571 25,253 2,925 2,925 2,925 2,925 2,925 790 790 790 790 790 1,232 1,232 1,232 1,232 1,232 E3N32 E3S32 E3H32 E3V32 E4H32 E4V32 E6V32 3200 3200 3200 3200 3200 3200 3200 65 75 100 130 100 150 150 22,337 23,340 23,724 25,367 23,842 25,731 38,539 24,698 25,701 26,085 27,728 26,203 28,092 40,900 2,925 2,925 2,925 2,925 6,259 6,259 7,398 790 790 790 790 1,664 1,664 2,783 1,232 1,232 1,232 1,232 1,696 1,696 2,464 E4S40 E4H40 E4V40 E6H40 E6V40 4000 4000 4000 4000 4000 75 100 100 100 150 30,399 34,540 38,681 44,177 50,140 32,760 36,901 41,042 47,701 52,501 6,259 6,259 6,259 7,398 7,398 1,664 1,664 1,664 2,783 2,783 1,696 1,696 1,696 2,464 2,464 E6H50 E6V50 5000 5000 100 150 45,541 53,341 47,902 55,702 7,398 7,398 2,783 2,783 2,464 2,464 E6H63 E6V63 6300 6300 100 150 64,163 78,427 66,524 80,788 7,398 7,398 2,783 2,783 2,464 2,464 Standard features – electrically operated breaker Moving part Standard features – electrically operated breaker Fixed part • • • • • • • • • • • • • • • • • • PR121 trip unit with LI protection functions Spring charging motor Shunt trip Closing coil Manual mechanical close and open pushbuttons CB open/closed mechanical indicator Spring charged/discharged mechanical indicator 2NO & 2NC auxiliary contacts for open-closed position indication Lifting plates Current transformers Racking device with closed door Circuit breaker racking position indicator Sliding contacts Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Set of Three Front Terminals 16 Safety shutters Rear horizontal terminals Sliding contacts Anti-insertion lock Ground connection Discount schedule ED1 - ED6 10/25/07 Rev. 16.23 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow Withdrawable breakers, 4 poles IEC P Withdrawable breakers 16 Cradle w/Rear Horizontal / Flat Terminals Set of Four Vertical Terminals Set of Four Front Terminals IEC Frame Amps Interrupting Ratings kA, 415V Manually Operated Electrically Operated E1B08 E1N08 E2S08 E3H08 E3V08 800 800 800 800 800 42 50 85 100 130 $ 7,717 8,605 9,998 10,398 10,554 $ 10,078 10,966 12,359 12,759 12,915 $ 2,572 2,572 3,192 3,890 3,890 $ 837 837 897 1,027 1,027 $ 489 489 1,183 1,643 1,643 E1B10 E1N10 E2N10 E2S10 E3S10 E3H10 1000 1000 1000 1000 1000 1000 42 50 65 85 75 100 9,621 9,717 10,155 10,307 10,988 11,103 11,982 12,078 12,516 12,668 13,349 13,464 2,572 2,572 3,192 3,192 3,890 3,890 837 837 897 897 1,027 1,027 489 489 1,183 1,183 1,643 1,643 E1B12 E1N12 E2N12 E2S12 E2L12 E3S12 E3H12 E3V12 1250 1250 1250 1250 1250 1250 1250 1250 42 50 65 85 130 75 100 130 10,649 11,098 11,372 11,772 14,395 11,906 12,229 15,445 13,010 13,459 13,733 14,133 17,763 14,267 14,590 17,806 2,572 2,572 3,192 3,192 3,192 3,890 3,890 3,890 837 837 897 897 897 1,027 1,027 1,027 489 489 1,183 1,183 1,183 1,643 1,643 1,643 E1B16 E1N16 E2B16 E2N16 E2S16 E2L16 E3S16 E3H16 E3V16 1600 1600 1600 1600 1600 1600 1600 1600 1600 42 50 42 65 85 130 75 100 130 10,812 11,375 11,395 12,873 13,460 17,501 12,472 13,304 18,408 13,173 13,736 13,756 15,234 15,821 22,625 14,833 15,665 20,769 2,572 2,572 3,192 3,192 3,192 3,192 3,890 3,890 3,890 837 837 897 897 897 897 1,027 1,027 1,027 489 489 1,183 1,183 1,183 1,183 1,643 1,643 1,643 E2B20 E2N20 E2S20 E3S20 E3H20 E3V20 E3L20 2000 2000 2000 2000 2000 2000 2000 42 65 85 75 100 130 130 13,851 15,661 16,825 14,873 16,784 19,212 22,714 16,212 18,022 19,186 17,234 19,145 21,573 25,075 3,192 3,192 3,192 3,890 3,890 3,890 3,890 897 897 897 1,027 1,027 1,027 1,027 1,183 1,183 1,183 1,643 1,643 1,643 1,643 E3N25 E3S25 E3H25 E3V25 E3L25 2500 2500 2500 2500 2500 65 75 100 130 130 20,380 22,816 24,938 27,125 29,312 22,741 25,177 27,299 29,486 31,673 3,890 3,890 3,890 3,890 3,890 1,027 1,027 1,027 1,027 1,027 1,643 1,643 1,643 1,643 1,643 E3N32 E3S32 E3H32 E3V32 E4S32 E4H32 E4H/f32 1 E4V32 E6V32 3200 3200 3200 3200 3200 3200 3200 3200 3200 65 75 100 130 75 100 100 150 150 29,555 29,893 32,017 34,141 33,317 32,589 33,523 47,423 49,722 31,916 32,254 34,378 36,502 35,678 34,959 35,884 49,784 52,083 3,890 3,890 3,890 3,890 8,324 8,324 9,513 8,324 9,839 1,027 1,027 1,027 1,027 2,163 2,163 2,472 2,163 3,618 1,643 1,643 1,643 1,643 2,260 2,260 2,583 2,260 3,286 E4S40 E4H40 E4H/f40 1 E4V40 E6H40 E6H/f40 1 E6V40 4000 4000 4000 4000 4000 4000 4000 75 85 100 100 100 100 150 41,350 44,409 45,478 45,930 48,486 50,911 58,496 43,711 46,770 47,839 48,291 60,857 53,272 60,857 8,324 8,324 9,513 8,324 9,839 11,245 9,839 2,163 2,163 2,472 2,163 3,618 4,135 3,618 2,260 2,260 2,583 2,260 3,286 3,756 3,286 E6H50 E6H/f50 1 E6V50 5000 5000 5000 100 100 150 58,680 66,853 56,568 61,041 69,214 71,181 9,839 11,245 9,839 3,618 4,135 3,618 3,286 3,756 3,286 E6H63 E6H/f63 E6V63 6300 6300 6300 100 100 150 82,888 94,017 101,432 85,249 96,378 103,793 9,839 9,839 9,839 3,618 4,135 3,618 3,286 3,756 3,286 Standard features – electrically operated breaker Moving part • Circuit breaker racking position indicator • Sliding contacts • • • • • • • • • • • • • • • • PR121 trip unit with LI protection functions Spring charging motor Shunt trip Closing coil Manual mechanical close and open pushbuttons CB open/closed mechanical indicator Spring charged/discharged mechanical indicator 2NO & 2NC auxiliary contacts for open-closed position indication Lifting plates Current transformers Racking device with closed door 1Special 100% neutral pole rating. 16.24 LV040 [1SXU200040C0202] - 10/07 10/25/07 Rev. Standard features – electrically operated breaker Fixed part Safety shutters Rear horizontal terminals Sliding contacts Anti-insertion lock Ground connection Neutral pole rating • E1 –E3 = 100% rating • E4 – E6 = 50% rating Discount schedule ED1 - ED6 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Non-automatic switches Fixed switches (Without trip unit & c.t.s.), 3 pole IEC 16 Po we Em r b ax re ak e rs Fixed switches, 3 pole IEC Frame Amps Rated Short Time Current, kA Manually Operated Electrically Operated Set of Three Vertical Terminals Set of Three Front Terminals E1B/MS08 E1N/MS08 E3V/MS08 800 800 800 42 50 85 $ 4,298 4,903 5,883 $ 6,659 7,264 8,244 $ 644 644 790 $ 367 367 1,232 E1B/MS10 E1N/MS10 E2N/MS10 E2S/MS10 E3S/MS10 1000 1000 1000 1000 1000 42 50 55 65 75 4,816 5,101 5,502 5,799 5,921 7,177 7,462 7,863 8,160 8,282 644 644 690 690 790 367 367 888 888 1,232 E1B/MS12 E1N/MS12 E2N/MS12 E2S/MS12 E3S/MS12 E3V/MS12 1250 1250 1250 1250 1250 1250 42 50 55 65 75 85 4,927 5,203 5,585 5,887 5,972 7,089 7,288 7,564 7,946 8,248 8,333 9,450 644 644 690 690 790 790 367 367 888 888 1,232 1,232 E1B/MS16 E1N/MS16 E2B/MS16 E2N/MS16 E2S/MS16 E3S/MS16 E3V/MS16 1600 1600 1600 1600 1600 1600 1600 42 50 42 55 65 75 85 5,203 5,307 5,564 6,285 6,722 6,864 8,145 7,564 7,668 7,925 8,646 9,083 9,225 10,506 644 644 690 690 690 790 790 367 367 888 888 888 1,232 1,232 E2B/MS20 E2N/MS20 E2S/MS20 E3S/MS20 E3V/MS20 2000 2000 2000 2000 2000 42 55 65 75 85 6,780 7,295 8,280 7,981 9,451 9,141 9,556 10,641 10,342 11,812 690 690 690 790 790 888 888 888 1,232 1,232 E3N/MS25 E3S/MS25 E3H/MS25 E3V/MS25 2500 2500 2500 2500 65 75 75 85 12,034 13,406 16,187 14,246 14,395 15,767 18,548 16,607 790 790 790 790 1,232 1,232 1,232 1,232 E3N/MS32 E3S/MS32 E3V/MS32 E4H/MS32 3200 3200 3200 3200 65 75 85 100 16,127 16,826 17,901 18,688 18,488 19,187 20,262 21,049 790 790 790 790 1,232 1,232 1,232 1,232 E4S/MS40 E4H/MS40 E6H/MS40 4000 4000 4000 75 100 100 24,504 28,276 33,114 26,865 30,637 35,475 1,664 1,664 2,783 1,696 1,696 2,464 E6H/MS50 5000 100 39,465 41,826 2,783 2,464 E6H/MS63 6300 100 47,874 50,235 2,783 2,464 16 Standard features – manually operated switch • • • • • • Rear horizontal terminals Manual mechanical close and open pushbuttons Circuit breaker open/closed mechanical indicator Spring charged/discharged mechanical indicator Lifting plates Terminal box Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Discount schedule ED1 - ED6 16.25 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow Non-automatic switches Fixed switches (Without trip unit & c.t.s.), 4 pole IEC P Fixed switches, 4 pole 16 IEC Frame Amps Rated Short Time Current, kA Manually Operated Electrically Operated E1B/MS08 E1N/MS08 E3V/MS08 800 800 800 42 50 85 $ 5,533 6,251 7,501 $ 7,894 8,612 9,862 $ 837 837 1,027 $ 489 489 1,643 E1B/MS10 E1N/MS10 E2N/MS10 E2S/MS10 E3S/MS10 1000 1000 1000 1000 1000 42 50 55 65 75 6,139 6,503 6,705 7,350 7,666 8,500 8,864 9,066 9,711 10,027 837 837 897 897 1,027 489 489 1,183 1,183 1,643 E1B/MS12 E1N/MS12 E2N/MS12 E2S/MS12 E3S/MS12 E3V/MS12 1250 1250 1250 1250 1250 1250 42 50 55 65 75 85 6,351 6,633 7,206 7,462 7,221 9,178 8,712 8,994 9,567 9,823 9,582 11,539 837 837 897 897 1,027 1,027 489 489 1,183 1,183 1,643 1,643 E1B/MS16 E1N/MS16 E2B/MS16 E2N/MS16 E2S/MS16 E3S/MS16 E3V/MS16 1600 1600 1600 1600 1600 1600 1600 42 50 42 55 65 75 85 6,633 6,766 7,179 8,117 8,636 8,328 10,444 8,994 9,127 9,540 10,478 10,997 10,689 12,805 837 837 897 897 897 1,027 1,027 489 489 1,183 1,183 1,183 1,643 1,643 E2B/MS20 E2N/MS20 E2S/MS20 E3S/MS20 E3V/MS20 2000 2000 2000 2000 2000 42 55 65 75 85 8,759 9,429 10,059 9,710 12,141 11,120 11,790 12,420 12,071 14,502 897 897 897 1,027 1,027 1,183 1,183 1,183 1,643 1,643 E3N/MS25 E3S/MS25 E3H/MS25 E3V/MS25 2500 2500 2500 2500 65 75 75 85 15,586 17,369 21,853 18,432 17,947 19,730 24,214 20,793 1,027 1,027 1,027 1,027 1,643 1,643 1,643 1,643 E3N/MS32 E3S/MS32 E3V/MS32 E4H/MS32 E4H/f MS32 1 3200 3200 3200 3200 3200 65 75 85 100 100 20,907 21,815 23,184 24,146 26,368 23,268 24,176 25,545 26,507 28,729 1,027 1,027 1,027 2,163 2,472 1,643 1,643 1,643 2,260 2,583 E4S/MS40 E4H/MS40 E4H/f MS40 1 E6H/MS40 E6H/f MS40 1 4000 4000 4000 4000 4000 75 100 85 100 100 31,815 36,721 39,196 39,352 43,116 34,176 39,082 41,557 41,713 45,477 2,163 2,163 2,472 3,618 4,135 2,260 2,260 2,583 3,286 3,756 E6H/MS50 E6H/f MS50 1 5000 5000 100 100 49,479 56,638 51,480 58,999 3,618 4,135 3,286 3,756 E6H/MS63 E6H/f MS63 1 6300 6300 100 100 59,991 68,802 62,352 71,163 3,618 4,135 3,286 3,756 Standard features – manually operated switch Neutral pole rating • • • • • • • E1 – E3 = 100% rating • E4 – E6 = 50% rating Rear horizontal terminals Manual mechanical close and open pushbuttons Circuit breaker open/closed mechanical indicator Spring charged/discharged mechanical indicator Lifting plates Terminal box Set of Four Vertical Terminals Set of Three Front Terminals 1Special 100% neutral pole rating. 16.26 LV040 [1SXU200040C0202] - 10/07 Discount schedule ED1 - ED6 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 P ow Em Non-automatic switches er ax Withdrawable switches (Without trip unit & c.t.s.), 3 pole break er s IEC Withdrawable switches, 3 pole IEC Frame Amps Rated Short Time Current, kA Manually Operated Electrically Operated E1B/MS08 E1N/MS08 E3V/MS08 800 800 800 42 50 85 $ 4,772 4,952 7,060 $ 7,133 7,313 9,421 E1B/MS10 E1N/MS10 E2N/MS10 E2S/MS10 E3S/MS10 1000 1000 1000 1000 1000 42 50 55 65 75 5,051 5,152 5,770 5,857 6,716 E1B/MS12 E1N/MS12 E2N/MS12 E2S/MS12 E3S/MS12 E3V/MS12 1250 1250 1250 1250 1250 1250 42 50 55 65 75 85 E1B/MS16 E1N/MS16 E2B/MS16 E2N/MS16 E2S/MS16 E3S/MS16 E3V/MS16 1600 1600 1600 1600 1600 1600 1600 E2B/MS20 E2N/MS20 E2S/MS20 E3S/MS20 E3V/MS20 Cradle w/Rear Horizontal / Flat Terminals Set of Three Vertical Terminals Set of Three Front Terminals $ 2,281 2,281 2,925 $ 644 644 790 $ 367 367 1,232 7,412 7,513 8,131 8,218 9,077 2,281 2,281 2,400 2,400 2,925 644 644 690 690 790 367 367 888 888 1,232 6,028 5,255 6,897 7,718 6,924 7,237 8,389 7,616 9,258 10,079 9,285 9,598 2,281 2,281 2,400 2,400 2,925 2,925 644 644 690 690 790 790 367 367 888 888 1,232 1,232 42 50 42 55 65 75 85 6,831 6,968 7,368 8,505 8,331 8,838 9,160 9,192 9,329 9,729 10,866 10,692 11,199 11,521 2,281 2,281 2,400 2,400 2,400 2,925 2,925 644 644 690 690 690 790 790 367 367 888 888 888 1,232 1,232 2000 2000 2000 2000 2000 42 55 65 75 85 9,258 9,453 9,648 9,525 10,737 11,619 11,814 12,009 11,886 13,098 2,400 2,400 2,400 2,925 2,925 690 690 690 790 790 888 888 888 1,232 1,232 E3N/MS25 E3S/MS25 E3V/MS25 E3N/MS32 E3S/MS32 E3V/MS32 E4H/MS32 2500 2500 2500 3200 3200 3200 3200 65 75 85 65 75 85 100 13,384 16,060 16,611 20,501 21,540 22,281 24,011 15,745 18,421 18,972 22,862 23,865 24,642 26,372 2,925 2,925 2,925 2,925 2,925 2,925 6,259 790 790 790 790 790 790 1,664 1,232 1,232 1,232 1,232 1,232 1,232 1,696 E4S/MS40 E4H/MS40 E6H/MS40 4000 4000 4000 75 100 100 28,030 32,171 36,789 30,391 34,532 39,150 6,259 6,259 6,259 1,664 1,664 2,783 1,696 1,696 2,464 E6H/MS50 5000 100 42,959 45,320 7,398 2,783 2,464 E6H/MS63 6300 100 61,581 63,942 7,398 2,783 2,464 Standard features – manually operated switch Moving part Standard features – manually operated switch Fixed part • • • • • • • • • • • • Manual mechanical close and open pushbuttons Circuit breaker open/closed mechanical indicator Spring charged/discharged mechanical indicator Lifting plates Racking device with closed door Circuit breaker racking position indicator Sliding contacts Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 Safety shutters Rear horizontal terminals Sliding contacts Anti-insertion lock Ground connection Discount schedule ED1 - ED6 10/25/07 Rev. 16.27 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow Non-automatic switches Withdrawable switches (Without trip unit & c.t.s.), 4 pole IEC P Withdrawable switches, 4 pole 16 IEC Frame Amps Rated Short Time Current, kA Manually Operated Electrically Operated E1B/MS08 E1N/MS08 E3V/MS08 800 800 800 42 50 85 $ 5,775 6,314 7,501 $ 8,136 8,675 9,862 E1B/MS10 E1N/MS10 E2N/MS10 E2S/MS10 E3S/MS10 1000 1000 1000 1000 1000 42 50 55 65 75 6,440 6,569 7,033 7,139 8,696 E1B/MS12 E1N/MS12 E2N/MS12 E2S/MS12 E3S/MS12 E3V/MS12 1250 1250 1250 1250 1250 1250 42 50 55 65 75 85 E1B/MS16 E1N/MS16 E2B/MS16 E2N/MS16 E2S/MS16 E3S/MS16 E3V/MS16 1600 1600 1600 1600 1600 1600 1600 E2B/MS20 E2N/MS20 E2S/MS20 E3S/MS20 E3V/MS20 E3N/MS25 E3S/MS25 E3V/MS25 Cradle w/Rear Horizontal / Flat Terminals Set of Four Vertical Terminals Set of Four Front Terminals $ 2,572 2,572 3,890 $ 837 837 1,027 $ 489 489 1,643 8,801 8,930 9,394 9,500 11,057 2,572 2,572 3,192 3,192 3,890 837 837 897 897 1,027 489 489 1,183 1,183 1,643 8,707 9,168 9,430 9,610 9,821 10,312 11,068 11,529 11,791 11,971 12,182 12,673 2,572 2,572 3,192 3,192 3,890 3,890 837 837 897 897 1,027 1,027 489 489 1,183 1,183 1,643 1,643 42 50 42 55 65 75 85 8,888 9,065 9,453 10,931 11,733 10,387 11,762 11,249 11,426 11,814 13,292 14,094 12,748 14,123 2,572 2,572 3,192 3,192 3,192 3,890 3,890 837 837 897 897 897 1,027 1,027 489 489 1,183 1,183 1,183 1,643 1,643 2000 2000 2000 2000 2000 2500 2500 2500 42 55 65 75 85 65 75 85 11,909 13,719 14,241 12,788 15,119 18,295 20,731 21,625 14,270 16,080 16,602 15,149 17,480 20,656 23,092 23,986 3,192 3,192 3,192 3,890 3,890 3,890 3,890 3,890 837 897 897 1,027 1,027 1,027 1,027 1,027 1,183 1,183 1,183 1,643 1,643 1,643 1,643 1,643 E3N/MS32 E3S/MS32 E3V/MS32 E4H/MS32 E4H/fMS32 1 3200 3200 3200 3200 3200 65 75 85 100 100 27,470 27,808 28,996 30,738 32,273 29,831 30,169 31,357 33,099 34,634 3,890 3,890 3,890 8,324 9,513 1,027 1,027 1,027 2,163 2,472 1,643 1,643 1,643 2,260 2,583 E4S/MS40 E4H/MS40 E4H/f MS40 1 E6H/MS40 E6H/f MS40 1 4000 4000 4000 4000 4000 75 100 100 100 100 38,555 41,614 45,598 43,359 45,527 40,916 43,975 47,959 45,720 47,888 8,324 8,324 9,513 9,839 11,245 2,163 2,163 2,472 3,618 4,135 2,260 2,260 2,583 3,286 3,756 E6H/MS50 E6H/f MS50 5000 5000 100 100 55,601 62,290 57,962 64,651 9,839 11,245 3,618 4,135 3,286 3,756 E6H/MS63 E6H/f MS63 1 6300 6300 100 100 79,809 88,561 82,170 90,922 9,839 11,245 3,618 4,135 3,286 3,756 Standard features – manually operated switch Moving part Standard features – manually operated switch Fixed part • • • • • • • • • • • • Manual mechanical close and open pushbuttons Circuit breaker open/closed mechanical indicator Spring charged/discharged mechanical indicator Lifting plates Racking device with closed door Circuit breaker racking position indicator Sliding contacts Safety shutters Rear horizontal terminals Sliding contacts Anti-insertion lock Ground connection Neutral pole rating • E1 – E3 = 100% rating • E4 – E6 = 50% rating 1Special 100% neutral pole rating. 16.28 LV040 [1SXU200040C0202] - 10/07 10/25/07 Rev. Discount schedule ED1 - ED6 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 Po we Em r b ax re ak e Air circuit breakers Installed optional features UL & IEC rs 1.20 Trip Units1 Factory installation price adder Part Numbers Field installable price PR121/P-LI PR121/P-LSI PR121/P-LSIG — $ 515 1,208 — $ 1,604 2 2,297 2 PR122/P-LI PR122/P-LSI PR122/P-LSIRc (IEC only) PR122/P-LSIG 1,686 2,210 3,189 2,904 2,775 3,299 4,278 3,993 PR123/P-LSI (Standard with PR120/V) PR123/P-LSIG (Standard with PR120/V) 6,631 7,323 7,720 8,412 1.21 Rating Plugs UL E1 E2 E3 DE0400RP DE0600RP DE0800RP DE1000RP DE1200RP DE1600RP DE2000RP DE2500RP DE3000RP DE3200RP DE3600RP DE4000RP DE5000RP X X X X X X X X X X X X X X X X X X X X X IEC E1 E2 E3 DE0400RP DE0630RP DE0800RP DE1000RP DE1250RP DE1600RP DE2000RP DE2500RP DE3000RP DE3200RP DE4000RP DE5000RP DE6300RP X X X X X X X X X X X X X X X X X X X X X X X E4 E6 X X X X X X X X X X X X X X X X X X X X E4 E6 X X X X X X X X X X X X X X X X X X X X Field installable price 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 16 1 Must order rating plug separately when ordering trip unit separately. 2 Requires PRO30/B to be purchased separately. See item 49 on page 16.36. Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Discount schedule EDX 16.29 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Air circuit breakers Installed optional features UL & IEC 1.22 Auxiliary Units Part Numbers PR010/T PR021/K PR120/K4 PR120/K4C PR120/V PR120/D-M PR120/D-BT BT030 Description Configuration Test Unit Signaling Unit Signaling Module 4 output with independent terminals Signaling Module 4 + 1 input with common terminal Voltage Measuring Module Communication Module (Modbus RTU) Bluetooth Wireless Communication Module internal Bluetooth Wireless Communication Module external List price $ 12,500.00 5,000.00 2,500.00 2,500.00 2,125.00 5,000.00 2,500.00 3,335.00 16 1 Standard connection when ordered with breaker. 16.30 LV040 [1SXU200040C0202] - 10/07 Discount schedule EDX Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 Po we Em r b ax re ak e Air circuit breakers Installed optional features UL & IEC rs 23. – 30. Electrical and mechanical accessories Item Factory Field installation installation catalog list price number adder 23a. Shunt trip coil (included in the electrically operated breaker) Rated voltage 24V 30V 48V 60V 110/120V $ 374 125/127V 220/240V 250V 380/400V 440/480V KE6S0 KE6S9 KE6S8 KE6S7 KE6S6 KE6S5 KE6S4 KE6S3 KE6S2 KE6S1 Field installation list price $ 374 23b. Second shunt trip coil (includes accessory support) 1 24V 30V 48V 60V 110/120V 456 125/127V 220/240V 250V 380/400V 440/480V KE6S0-2 KE6S9-2 KE6S8-2 KE6S7-2 KE6S6-2 KE6S5-2 KE6S4-2 KE6S3-2 KE6S2-2 KE6S1-2 456 24. Closing coil (included in the electrically operated breaker) Rated voltage 24V 30V 48V 60V 110/120V 374 125/127V 220/240V 250V 380/400V 440/480V KE6C0 KE6C9 KE6C8 KE6C7 KE6C6 KE6C5 KE6C4 KE6C3 KE6C2 KE6C1 374 25. Spring charging motor with limit switch and electrical indication charged spring (included in the electrically operated breaker) Rated voltage 24/30V 48/60V 1613 100/130V 220/250V KE6M9 KE6M7 KE6M5 KE6M3 1613 73 KE6SC 73 Rated voltage 24V 30V 48V 60V 110/120V 456 125/127V 220/240V 250V 380/400V 440/480V KE6U0 KE6U9 KE6U8 KE6U7 KE6U6 KE6U5 KE6U4 KE6U3 KE6U2 KE6U1 456 27. Energized undervoltage release signalling contact Auxiliary contact normally open 82 Auxiliary contact normally closed KE6UE10 KE6UE01 Spring charged signal only 26. Instantaneous under voltage trip release 82 1 Order as alternative to UV trip. Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Discount schedule EDX 16.31 LV040 [1SXU200040C0202] - 10/07 16 16 rs ax ake m E bre er ow P Air circuit breakers Installed optional features UL & IEC Item Factory Field installation installation catalog list price number adder Field installation list price 28. Auxiliary contacts for breakers 1 Rated 5A-250VAC / 0.3A –125VDC 28a. 4 auxiliary open/closed contacts (PR121/ on-automatic switch) 28b. 4 auxiliary open/closed contacts for digital signals (PR121/non-automatic switch) 28c. 4 auxiliary open/closed contacts (2NO+2NC+2PR122-3) 28d. 4 auxiliary open/closed contacts (2NO+2NC+2PR122-3) for digital signals 28e. 10 auxiliary open/closed contacts (PR121/non-automatic switch) 28f. 10 auxiliary open/closed contacts for digital signals (PR121/non-automatic switch) 28g. 10 auxiliary open/closed contacts (5NO+5NC+2PR122-3) 28h. 10 auxiliary open/closed contacts (5NO+5NC+2PR122-3) for digital signals 28i. 15 additional auxiliary contacts for field installation on fixed breakers (connected to breaker with flexible cable) 28j. 15 additional auxiliary contacts for field installation on withdrawable breakers (connected to breaker with flexible cable) 2 29. Auxiliary contacts for switches 29a. 2NO + 2NC 29b. 5NO + 5NC – 297 – 297 753 753 753 753 1507 KE6A4 KE6A4D KE6A4-PR122/3 KE6A4-PR122/3D KE6A10 KE6A10D KE6A10-PR122/3 KE6A10-PR122/3D KE6A15 $ 297 297 297 297 1050 1050 1050 1050 1507 1507 KE6A15-W 1507 297 1050 KE6A4 KE6A10 297 1050 30. – 33. Electrical and mechanical accessories Item 30. Factory Field installation installation catalog list price number adder Auxiliary contacts for service/test/disconnected position indication Cradle mounted 30a. 5 auxiliary contacts 30b. 10 auxiliary contacts for E1/2 3 pole 30c. 10 auxiliary contacts for E1/2 4 pole 30d. 10 auxiliary contacts for E3 3 pole 30e. 10 auxiliary contacts for E3 4 pole 30f. 10 auxiliary contacts for E4/6 3/4 pole Field installation list price 377 753 753 753 753 753 KE6PS1 KE2PS3 KE2PS4 KE3PS3 KE3PS4 KE6PS2 377 753 753 753 753 753 31. Mechanical operation counter 418 KE6MC 418 32. Bell alarm Electrical signalling of overcurrent release tripped, Bell alarm contact 348 DE6TBA 348 DE6TBAR4 DE6TBAR5 DE6TBAR9 545 33. Bell alarm w/remote reset 33a. Electrical signalling of overcurrent release tripped with remote reset 220-240V AC/DC 33b. Electrical signalling of overcurrent release tripped with remote reset 110-130V AC/DC 545 33c. Electrical signalling of overcurrent release tripped with remote reset 24-30V AC/DC 16 1 For field installation, order auxiliary contacts for corresponding trip unit/ 2 Order as alternative to various types of interlock and kirk key lock. For mounting on fixed breaker, also requires accessory 32 (KE6MLP). 16.32 LV040 [1SXU200040C0202] - 10/07 Discount schedule EDX non-automatic switch. Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 Po Air circuit breakers optional features UL & IEC we Em r b ax re ak e rs 34. – 39. Locks and interlocks Item 34. Button guard 35. Factory Field installation installation catalog list price number adder $ 48 Key lock in open position 35a. Key lock N. 20005 1 35b. Key lock N. 20006 35c. Key lock N. 20007 202 35d. Key lock N. 20008 35e. Key lock different keys Field installation list price KE6PG $ 48 DE6KL2 DE6KL3 DE6KL4 DE6KL5 DE6KL1 202 36a. Padlocking button cover (padlocks not supplied) 3 - 4mm locks 162 KE6PD1 162 36b. 3 - 5/16 locks 350 KE6PDHD1 350 DE6PL2 DE6PL3 DE6PL4 DE6PL5 DE6PL1 202 37. Key and padlocking device to lock the breaker in disconnected, test or connected position (position lock) 37a. Key + padlocking 20005 2 37b. Key + padlocking 20006 37c. Key + padlocking 20007 202 37d. Key + padlocking 20008 37e. Key + padlocking different keys 38. Key and padlocking device to lock the breaker in test or disconnected position only Position lock 212 KE6PLA 212 39. Padlocking device for the safety shutters on the cradle Cradle padlock N/A KE6SP 43 16 1 Keylock number when factory installed is N3004222. 2 Keylock number when factory installed is 20005. Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.33 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow External accessories Current transformers, UL & IEC P 40a. Neutral current transformer (required for 4 wire ground fault systems) For breaker Amps Catalog number List price E1 – E2 400A 800A 1000A 1200A KE2NCT 1250A 1600A 2000A $ 406 E3 400A 800A 1000A 1200A 1250A KE3NCT 1600A 2000A 2500A 3200A 414 E4 1600A 2000A 2500A KE4NCT 1 3200A 3600A 4000A 818 E6 3200A 4000A KE6NCT 1 5000A 6300A 834 16 1 KE4NCT & KE6NCT are 100% rated. For 50% rated neutrals on E4 & E6, use KE2NCT & KE3NCT 16.34 LV040 [1SXU200040C0202] - 10/07 Discount schedule EDX Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16 Po we Em r b ax re ak e External accessories Mechanical interlocks1 rs 41. Mechanical interlocks (base plate for fixed circuit breaker) For breaker Interlock type E1 – E6 Catalog number All KE6MLP List price $ 241 NOTE: order for fixed circuit breaker only; order one accessory for each fixed breaker. 42. Interlock for fixed circuit breaker/fixed part of withdrawable circuit breaker (cable attachment plate) For breaker Interlock type E1 – E6 Catalog number A, B, D C KE6MLA KE6MLC List price $ 628 NOTE: order one accessory for each fixed circuit breaker/fixed part of withdrawable circuit breaker 43. Interlock for fixed circuit breaker/moving part of withdrawable circuit breaker (internal interlocking shaft) For breaker Interlock type Catalog number E1 – E2 E3 E4, 3 pole All E4, 4 pole/ E6, 3 pole E6, 4 pole KE2ML KE3ML KE4ML-3 KE6ML-3 KE6ML-4 List price $ 145 NOTE: order one accessory for each fixed circuit breaker/mobile part of withdrawable circuit breaker 44. Interlock cables For breaker Interlock type E1 – E6 A B C D Horizontal Catalog number Vertical Catalog number KE6MLC-HA KE6MLC-HB KE6MLC-HC KE6MLC-HD KE6MLC-VA KE6MLC-VB KE6MLC-VC KE6MLC-VD List price $ 97 193 193 193 NOTE: order one type of cable for each interlock 16 1 Order as an alternative to the Accessory number 15 auxiliary contact (see page 16.32) and kirk key lock. Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Discount schedule EDX 16.35 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow External accessories Other items P 45. Electronic time delay for undervoltage release 1 Item 45. Field installation catalog number Delay Time delay Voltage 24/30V 48V 60V 0.5-1-1.5-2-3.5 s 110/125V 220/250V KE6TL9 KE6TL8 KE6TL7 KE6TL5 KE6TL3 List price $ 428 46. TransparSent front cover (IP54) For breaker 46. Cover Catalog number E1 – E6 KE6DC List price $ 557 47. Kirk key lock adaptor plate (in open position) For breaker 47. Catalog number Kirk key lock adaptor plate 47a. E1 – E2 fixed breaker, 3-4 pole 47b. E1 – E2 withdrawable breaker, 3-4 pole 47c. E3 fixed breaker, 3-4 pole 47d. E3 withdrawable breaker, 3-4 pole 47e. E4 fixed breaker, 3 pole 47f. E4 withdrawable breaker, 3 pole 47g. E6 fixed breaker, 3 pole 47h. E6 withdrawable breaker, 3 pole 47i. E4 fixed breaker, 4 pole 47j. E4 withdrawable breaker, 4 pole 47k. E6 fixed breaker, 4 pole 47l. E6 withdrawable breaker, 4 pole KE6KKC-E2F KE6KKC-E2W KE6KKC-E3F KE6KKC-E3W KE6KKC-E4F KE6KKC-E4W KE6KKC-E6F KE6KKC-E6W KE6KKC-E4F-F KE6KKC-E4W-4 KE6KKC-E6F-4 KE6KKC-E6W-4 List price $ 1436 1195 1436 1195 1436 1195 1436 1195 1436 1195 1436 1195 NOTE: Provision for kirk lock (kirk key lock not included; use lock Type F – 1 inch bolt projection in withdrawn position). 48. Kit for converting fixed breaker with rear horizontal terminals to rear vertical (set of three terminals) Item 16 48. Conversion kit 2 48a. 1/2 3p F HR > F VR E1-A 48b. 1/2 3p F HR > F VR E2-A 48c. 1/2 3p F HR > F VR E3-A (08, 16, 20) 48d. 1/2 3p F HR > F VR E3-A (25) 48e. 1/2 3p F HR > F VR E3-A (ALL) 48f. 1/2 3p F HR > F VR E4-A 48g. 1/2 3p F HR > F VR E6-A IEC Catalog number 1SDA038052R1 1SDA038053R1 — — 1SDA038054R1 1SDA038055R1 1SDA038056R1 UL Catalog number List price KE1FHRVR KE2FHRVR KE3FHRVR KE3F25HRVR $ 644 690 790 790 KE4FHRVR KE6FHRVR 1664 2783 49. – 50. Test kits Item 49. Hand-held battery (standard w/PR122 & 123) 50. Test and configuration unit SACE PR010/T PR030/B PR010/T 51. – 54. Spare parts Item 51. 52. 53. 54. Catalog number Racking crank Door escutcheon Support plate for auxiliary releases Lifting plates Catalog number 1SDA038092R1 1SDA038096R1 1SDA038339R1 1SDA038093R1 List price 275 12,500 List price $ 122 153 244 224 1 IEC only. 2 UL only 16.36 LV040 [1SXU200040C0202] - 10/07 Discount schedule EDX Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Approximate dimensions (for UL version) 1 E1, fixed with horizontal rear terminals 3 pole 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.37 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E1, fixed with horizontal rear terminals 4 pole 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.38 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E1, withdrawable with horizontal rear terminals 3 pole 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.39 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E1, withdrawable with horizontal rear terminals 4 pole 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.40 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E1 - E2, withdrawable with vertical rear terminals 3 pole 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.41 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E1 - E2, withdrawable with vertical rear terminals 4 pole 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.42 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E2, fixed with horizontal rear terminals 3 pole 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.43 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E2, fixed with horizontal rear terminals 4 pole 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.44 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E2, withdrawable with horizontal rear terminals 3 pole 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.45 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E2, withdrawable with horizontal rear terminals 4 pole 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.46 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E3, fixed with horizontal rear terminals 3 pole 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.47 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E3, fixed with horizontal rear terminals 4 pole 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.48 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E3, withdrawable with horizontal rear terminals 3 pole 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.49 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E3, withdrawable with horizontal rear terminals 4 pole 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.50 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E3 (2500A), withdrawable with vertical rear terminals 3 pole 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.51 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E3 (2500A), withdrawable with vertical rear terminals 00.00 4 pole 00.00 Inches [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.52 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E3 (1200A/1600A/2000A), withdrawable with Vertical rear terminals, 3 pole 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.53 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E3 (1200A/1600A/2000A), withdrawable with Vertical rear terminals, 4 pole 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.54 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E3 (3200A), fixed with Vertical rear terminals, 3 pole 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.55 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E3 (3200A), fixed with Vertical rear terminals, 4 pole 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.56 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E3 (3200A), withdrawable with Vertical rear terminals, 3 pole 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.57 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E3 (3200A), withdrawable with Vertical rear terminals, 4 pole 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.58 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E3X Draw-out with Vertical rear terminals, 3 pole, 800-1200A 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.59 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E3X Draw-out with Vertical rear terminals, 3 pole, 1600-2000A 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.60 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E3X Fixed with Vertical rear terminals, 3 pole, 800-2000A 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.61 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E3X Draw-out with Vertical rear terminals, 4 pole, 1600-2000A 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.62 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E3X Fixed with Vertical rear terminals, 4 pole, 800-2000A 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.63 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E4, fixed with horizontal rear terminals 3 pole 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.64 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E4, fixed with horizontal rear terminals 4 pole (50% neutral) 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.65 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E4, fixed with horizontal rear terminals 4 pole (100% neutral) 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.66 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E4, withdrawable with horizontal rear terminals 3 pole 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.67 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E4, withdrawable with horizontal rear terminals 4 pole (50% neutral) 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.68 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E4, withdrawable with horizontal rear terminals 4 pole (100% neutral) 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.69 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E4, withdrawable with vertical rear terminals 3 pole 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.70 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E4, withdrawable with vertical rear terminals 4 pole (50% neutral) 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.71 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E4, withdrawable with vertical rear terminals 4 pole (100% neutral) 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.72 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E6, fixed with horizontal rear terminals 3 pole 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.73 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E6, fixed with horizontal rear terminals 4 pole (50% neutral) 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.74 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E6, fixed with horizontal rear terminals 4 pole (100% neutral) 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.75 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E6, withdrawable with horizontal rear terminals 3 pole 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.76 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E6, withdrawable with horizontal rear terminals 4 pole (50% neutral) 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.77 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E6, withdrawable with horizontal rear terminals 4 pole (100% neutral) 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.78 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E6, withdrawable with vertical rear terminals 3 pole 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.79 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E6, withdrawable with vertical rear terminals 4 pole (50% neutral) 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.80 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E6, withdrawable with vertical rear terminals 4 pole (100% neutral) 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.81 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Approximate dimensions (for UL version) 1 E1 - E6, fixed with vertical rear terminals 3 pole 00.00 Inches 00.00 [Millimeters] 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf 16.82 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 00.00 Inches 00.00 [Millimeters] Approximate dimensions (for UL version) 1 E1 - E6, fixed with vertical rear terminals 4 pole 16 Po we Em r b ax re ak e rs 16 1 For IEC dimensions, see Emax technical catalog 1SDC200005D0201 available for download at: http://www.abb-control.com/pdf/catalog/1SDC200005D0201.pdf Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.83 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow Emax Circuit Breaker Submittal Sheet Request for Quote Form P Date Customer Name From Account No. Location Contact Name Phone No. Location Fax No. Phone No. Comments Fax No. 00.00 Inches 00.00 [Millimeters] RFQ No. Due Date Close Date Quantity 1=1, 3P 4=4, 3P B=2, 4P F=6, 4P 50% neutral 2=2, 3P 6=6, 3P C=3, 4P G=4, 4P 100% neutral 3=3, 3P A=1, 4P D=4, 4P 50% neutral H=6, 4P 100% neutral B=basic S=standard V=very high X=200kA N=normal H=high L=limiting (IEC only) A=800 D=2000 G=3600 N=6300 (IEC only) B=1200/1250 E=2500 H=4000 P=1000 (IEC only) C=1600 F=3200 J=5000 A=400 E=1200/1250 J=3000 (UL only) N=5000 B=600/630 F=1600 K=3200 P=6300 (IEC only) C=800 G=2000 L=3600 (UL only) D=1000 H=2500 M=4000 0=None (non-automatic only B = fixed, UL F=Fixed, IEC Q = 1000VAC D = drawout, UL, less cradle W=drawout, IEC, less cradle R = 750VDC (3P) 1000VDC (4P) A = PR121/P, LI D = non-automatic G = PR122/PD, LSIG B = PR121/P, LSI E = PR122/P, LI H = PR122/PD, LSIRc C = PR121/P, LSIG F = PR122/P, LSI J = PR123/P,LSI+PR120/V 0 = none F=A+C M=B+C T=A+N+C+D A = PR120/K4C G=A+D N = PR120/VT U=N+C B = PR120/VB std. on PR123/P H=A+B+C P=A+N V=B+D C = PR120/D-M J=B+C+D Q=A+N+C W=N+D D = PR120/D-BT K=A+C+D R=A+N+D E=A+B L=A+B+C+D S=N+C+D Closing coil: 0 = none C = 48 F = 125 – 127 J = 380 – 400VAC 50/60Hz & VDC: A = 24VDC D = 60 G = 220– 240 K = 440 – 480VAC B = 30 E = 110 – 120 H = 250 A = 4 aux D = UV energ.NO G=A&E B = 10 aux E = UV energ.NC H=B&D F=A&D J=B&E Frame Size Breaking Capacity Frame Ampere Rating Rating Plug: Version Trip unit: 16 Trip unit accessories: Contacts: Spring charging motor: (includes spring charged signal, P/N does not show) 16.84 LV040 [1SXU200040C0202] - 10/07 D 0 = none C = 110-130VAC/VDC, A = 24 – 30VAC/VDC, D = 220 – 250VAC/VDC, B = 48 – 60VAC/VDC E = spring charged signal only K = PR123/ P,LSIG+PR120/V Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 0 = none Shunt trip: C = 48VAC/DC F = 125 – 127VAC/DC 16 J = 380 – 400VAC A = 24VDC D = 60VAC/DC G = 220– 240VAC/DC K = 440P–o480VAC E Undervoltage trip: 00.00 Inches 0 = none C = 48VAC/DC F = 125 – 127VAC/DC J = 380 – 400VAC 00.00& VDC: [Millimeters] 50/60Hz A = 24VDC D = 60VAC/DC G = 220– 240VAC/DC K = 440 – 480VAC OR B = 30VAC/DC E = 110 – 120VAC/DC H = 250VAC/DC N = 48VAC/DC R = 125 – 127VAC/DC U = 380 – 400VAC L = 24VDC P = 60VAC/DC S = 220– 240VAC/DC V = 440 – 480VAC M = 30VAC/DC Q = 110 – 120VAC/DC T = 250VAC/DC X = none F=A+B A = mechanical counter G=A+C B = bell alarm H=A+D C = bell alarm w/remote reset 24-30VAC/DC J=A+E 50/60Hz & VDC: EmaxB =Circuit Breaker Submittal Sheet 30VAC/DC E = 110 – 120VAC/DC H = 250VAC/DC Request for Quote Form Second Shunt trip: 50/60Hz & VDC: Accessories: w m br ea er ax L = low Z 120-127VAC/DC ke rs D = bell alarm w/remote reset 110-130VAC/DC E = bell alarm w/remote reset 220-240VAC/DC Locking Provisions X = none F=A+B M=C+D T = Heavy duty padlock, KE6PDHD1 A = Keylock G=A+C N=C+E U=A+T B = button guard H=A+D P=A+B+D V=T+D C = padlock provision (open) J=A+E Q=A+B+E W=T+E D = withdrawable position lock (connected, test and disconnected positions) K=B+D R=A+C+D Y=A+T+D E = withdrawable position lock ( test and disconnected positions) L=B+E S=A+C+E Z=A+T+E 1 = 1, 3P 6 = 6, 3P D = 4, 4P (50% neutral) 2 = 2, 3P A = 1, 4P F = 6, 4P (50% neutral) 3 = 3, 3P B = 2, 4P G = 4, 4P (100% neutral) 4 = 4, 3P C = 3, 4P H = 6, 4P (100% neutral) C = IEC cradle UL cradle Cradles Frame Size: Version: N = E1B-A; E1N-A; E2B-A E2N-A L = E4V-A; E4L-A H = E2S-A; E2H-A; E4S-A; E4H-A; E4H-A/f; E6H-A; E6H-A/f X = E3X-A2; E6V-A; E6LA; E6X-A S = E3N-A; E3S-A; V=E3H-A; E3V-A 12 = 1200 (E1) UL 25 = 2500 (E3) UL 50 = 5000 (E6) UL 32 = 3200 (E3) IEC 16 = 1600 (E2) UL 32 = 3200 (E3) UL 12 = 1250 (E1) IEC 40 = 4000 (E4) IEC 20 = 2000 (E3) UL 36 = 3600 (E4) UL 20 = 2000 (E4) IEC 63 = 6300 (E6) IEC Terminal Types: H = HH A = HV E = HL (IEC only) M = VL (IEC only) (1st letter is upper terminal, 2nd letter is lower terminal) H= Rear Horizontal/V = Rear Vertical/F = Front/L = Rear Flat V = VV B = VH G = LH (IEC only) N = LV (IEC only) F = FF (IEC only) C = HF (IEC only) J = VF (IEC only) P = FL (IEC only) L = LL (IEC only) D = FH (IEC only) K = FV (IEC only) Q = LF (IEC only) Maximum Ampere Rating: Contacts: 16 0 = none A = 5 position auxiliaries, TOC B = 10 position auxiliaries, TOC Options: X = none R = DC rated (750 V 3P, 1000V 4P) IEC only Approved By: Date: Accepted By: Date: Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 16.85 LV040 [1SXU200040C0202] - 10/07 16 rs ax ake m E bre er ow P Notes 00.00 Inches 00.00 [Millimeters] 16 16.86 LV040 [1SXU200040C0202] - 10/07 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Publication LV040 No. 1SXU 200 040 C0202 Printed in USA, October, 2007 ABB Inc. 1206 Hatton Road Wichita Falls, TX 76302 Telephone 888-385-1221; 940-397-7000 Fax 940-397-7085 http://www.abb-control.com