Electrical distribution products
Contractor quick selector guide
Our History
•
•
•
•
•
Over 90 years of servicing electrical needs for all markets.
It began in 1924 when Schaedler Brothers was created by Harry,
Andrew, and William Schaedler, a sibling partnership that started
simply with the purchasing, plating, assembling, and selling of light
fixture parts.
Twenty years later, Motter Electric Company was incorporated to
distribute electrical supplies. In 1956, Motter officially changed its
name to York Electrical Supply Company (YESCO).
In 1999, Schaedler Brothers, Inc., and YESCO merged, creating
what to this day is the largest electrical distributor headquartered in
Central Pennsylvania.
As part of our heritage, we have developed the same capabilities of a
large chain, but continue to operate as your neighborhood supplier
with a personal touch. We invite you to try all of our services from
basic to specialty.
Schaedler Yesco Distribution, Inc. is a
leading electrical distributor of top-quality
products from preferred manufacturers
of electrical, automation, lighting, data
communication, energy, and oil and gas
supplies. We pride ourselves on offering a
variety of products from brands you trust
that fit your current need and budget.
We make every effort to monitor and
adjust our product selection and inventory
requirements so you have access to what
you need, when you need it. Our convenient
locations, will-call counter pick-ups, and
vast delivery vehicle fleet ensure the
fast turnaround you would expect from a
preferred business partner.
Our Mission
To enhance our customers’ performance and profitability by being the
leading provider of distributor services and solutions.
Markets We Serve
Services We Provide
Industrial
Delivery
OEM (Original Equipment Manufacturer)
Emergency Services
Construction
Recycling Services
Commercial
Return Policy
Government
Inventory Management Solutions (IMS)
Oil & Gas
Technical & Product Specialists
www.sydist.com • 1-800-998-1621
Web Order Entry
Training
Safety Switches
General Duty
General Duty Safety Switches
240V Fusible
2P, 2F, and Neutral   
Accessories (General and Heavy Duty)
240V AC / 250V DC
Ampere
Rating
Indoor Type 1
Catalog Number
Outdoor Type 3R
Catalog Number
30
GF221N
GF221NR
60
GF222N
GF222NR
100
GF223N
GF223NR
200
GF224N
GF224NR
400
GF225NH 
GF225NRH 
400
GF225N
GF225NR
600
GF226NH 
GF226NRH 
600
GF226N
GF226NR
3P, 3F, and Neutral 
240V AC / 250V DC
Ampere
Rating
Indoor Type 1
Catalog Number
Outdoor Type 3R
Catalog Number
30
GF321N
GF321NR
60
GF322N
GF322NR
100
GF323N
GF323NR
200
GF324N
GF324NR
400
GF325NH 
GF325NRH 
400
GF325N
GF325NR
600
GF326NH 
GF326NRH 
600
GF326N
GF326NR
240V Non-Fusible
2P or 3P  
240V AC / 250V DC
Class R Fuse Clip Kits
Catalog Number
Description
GSRK321
Class R Fuse Clip Kit (30A General Duty Only)
HR21
Class R Fuse Clip Kit (30A, 240V Heavy Duty Only)
HR612 
Class R Fuse Clip Kit (30A, 600V / 60A, 240V)
HR62
Class R Fuse Clip Kit (60A, 600V)
HR63
Class R Fuse Clip Kit (100A)
HR64
Class R Fuse Clip Kit (200A)
HR656
Class R Fuse Clip Kit (400A / 600A)
Neutral Kits
Description
Kit Catalog Number
30 GD
W410190
30 HD. 60 GD
HN612 g
60, 100 HD, 100 GD
HN623 g
200
HN64
400 & 600
HN656
800 & 1200
HN678
Equipment Ground Kits
Switch Ampere
Rating
Catalog
Number
Number Of
Terminals
Wire Range Per
Terminal (Cu/Ai)
30A GD
GSGK60
2
#14-8 AWG
60-200GD
HG61234
2
#14-4 AWG
30-200 HD
HG61234
2
#14-4 AWG
400 & 600
HG656
4
#14-2/0 AWG
800-1200
HG678
8
#6 AWG-250 Kcmil
Ampere
Rating
Indoor Type 1
Catalog Number
Outdoor Type 3R
Catalog Number
30
GNF321
GNF321R
60
GNF322
GNF322R
100
GNF323
GNF323R
200
GNF324
GNF324R
400
GNF325
HNF365R
Use 600V Switch
With 1 NO & 1 NC Isolated Contacats
30-200
HA161234 
GNF326
HNF366R
Use 600V Switch
400-1200
HA165678 
600
 These switches are UL listed for application on grounded B-phase systems.
 Suitable for use on 3-phase motor loads.
 Service entrance rated.
 Height reduced switches (45.25" rather than 56" in height) for use with
500MCM or smaller conductors.
 Also for 60A, 240V General Duty and Heavy Duty.
 Provides 1 normally open and 1 normally closed contact.
g GD = General Duty, HD = Heavy Duty
4
4
www.sydist.com
www.sydist.com/SiemensMurray
Auxiliary Contacts
Switch
Ampere
Aux. Switch
Catalog
Number
Kit Ampere Rating
125V ACMax.
Horsepower Rating
250V AC
Max.
28V
Dc Max.
125V AC
Max.
250V AC
Max.
10
10
7
1/2
3/4
10
10
–
1/2
3/4
Safety Switches
Heavy Duty
Heavy Duty Safety Switches
600V Non-Fusible
600V Fusible
480V AC / 600V AC / 600V DC
2P, 2F  
480V AC / 600V AC / 600V DC
2P  
Outdoor Type 3R
Catalog Number
Ampere
Rating
Indoor Type 1
Catalog Number
Outdoor Type 3R
Catalog Number
HF261
HF261R
30
HNF261
HNF261R
HF262
HF262R
60
HNF262
HNF262R
Ampere
Rating
Indoor Type 1
Catalog Number
30
60
100
HF263
HF263R
100
HNF263
HNF263R
400
HF265 
HF265R 
400
HNF265 
HNF265R
600
HF266 
HF266R 
600
HNF266 
HNF266R 
3P, 3F 
480V AC / 600V AC / 250V DC
Heavy Duty Safety Switches
600V Non-Fusible
Ampere
Rating
Indoor Type 1
Catalog Number
Outdoor Type 3R
Catalog Number
30
HF361
HF361R
60
HF362
HF362R
Ampere
Rating
Indoor Type 1
Catalog Number
480V AC / 600V AC / 250V DC
3P 
Outdoor Type 3R
Catalog Number
100
HF363
HF363R
30
HNF361
HNF361R
200
HF364
HF364R
60
HNF362H 
HNF362RH 
400
HF365H 
HF365RH 
60
HNF362
HNF362R 
400
HF365
HF365R
100
HNF363
HNF363R 
600
HF366H
200
HNF364
HNF364R 

HF366RH

600
HF366
HF366R
400
HNF365
HNF365R
800
HF367
HF367R
600
HNF366
HNF366R
1200
HF368
HF368R
800
HNF367
HNF367R
1200
HNF368
HNF368R
Conduit Size (Inches)
Catalog Number
Used On
Cover
ECHA000
3/4
ECHA075
1
ECHA100
1 1/4
ECHA125
Cover
ECHS000
3/4
ECHS075
1
ECHS100
1 1/4
ECHS125
1 1/2
ECHS150
2
ECHS200
2 1/2
ECHS250
2 1/2
ECHV250
3
ECHV300
3 1/2
ECHV350
4
ECHV400
3P, 3F, and Neutral 
480V AC / 600V AC / 250V DC
Ampere
Rating
Indoor Type 1
Catalog Number
Outdoor Type 3R
Catalog Number
30
HF361N
HF361NR
60
HF362N
HF362NR
100
HF363N
HF363NR
200
HF364N
HF364NR
400
HF365N
HF365NR
600
HF366N
HF366NR
800
HF367N
HF367NR
1200
HF368N
HF368NR
Built to order. Allow 3 - 5 weeks for delivery.
 Suitable for use as service entrance equipment except for
1200 when used on a 480 or 600V grounded wye system.
 Use 3-Pole switch for 200A application.
 Compact switch (11.1”H, 6.6”W box less cover and handle).
Short circuit withstand rating—100,000 RMS sym. amps.
 60-200A 3-Pole switches are also rated 600V DC.
 Height reduced switch (45.25 rather than 56 inches in height) for use with
500MCM or smaller conductors.
 Hubs suitable for 3R switches.
Hubs Type 3R 
30A GD Only
60–200A GD
30–200A HD
400–1200A
www.sydist.com www.sydist.com/SiemensMurray
5
New Revised P1 Unassembled Panelboards
To better serve the needs of customers, Authorized Siemens Unassembled Panelboard Distributors offer product
flexibility, quicker job turn-around, and affordable pricing. All Siemens unassembled panelboards are fully backed for
high quality, trouble-free operation and are labeled as Suitable for use as Service Entrance Equipment.
Flexibility and ease of assembly:
Customer oriented design creates installation convenience.
For all of its one-of-a-kind features, the P1 panelboard is also
designed to be extremely userfriendly. For instance, field
convertible main breaker and main lug kits, (through 400 amps),
will allow you to switch from main lug to main breaker, and vice
versa with no change in box size or additional cabling. Plus, lay-in
construction (for 250 A CU) and/or removable lugs make wiring
the main and neutral lugs easier and faster. To further speed
wiring, as well as reduce clutter, the P1 panel also features a split
neutral design and branch neutral connections which are closer
to the breakers than competitors. Additionally, field addable
sub-fed breakers (up to 250 amps) or feed through lug kits can
be field installed without utilizing any of your feeder breaker
positions or increasing your box height. Furthermore, the unique
design allows the panel to be inverted in the field and keep its
labeling legible.
1) Completely symmetrical boxes may be mounted with
either end up. There are two pre-punched equipment ground
connector locations for contractor friendly installation.
be performed easily. MLO kits and Main Breaker Kits are
interchangeable and can be changed/added in the field without
making changes to the enclosure or interior.
2) Box comes pre-punched for optional, field installable doorin-door or hinged style trims. There are also two pre-punched
ground connector locations. The panel box will accept both
standard ground connector (EGK and ECGK) assemblies and
insulated ground connector kits (IGK and ICGK).
5) Branch neutral connections are near the breaker connections
to speed wiring and reduce clutter. The standard P1 neutral
is rated for 100% of the panel’s ampacity and will accept copper
or aluminum wire. Optional 200% and 2/0 neutrals are
also available.
3) Interior is completely symmetrical allowing it to be changed
from top to bottom feed by simply rotating the interior.
6) The panel includes space to add (1) sub-feed breaker (max
250 amps), feed-thru lugs or TPS3 (SPD) kit.
4) Choose either a Main Breaker kit or Main Lug kit with which
to terminate your incoming cables. Main lug kits are contractor
friendly lugs through 350 kcmil (250 amp panel) or (1) 600
kcmil or (2) 250 kcmil connectors for 400 amp panels. No line
connectors in the P1 panel require multiple wires under one
screw. Main Breaker kits (250 amps and below) are horizontally
mounted allowing field convertible top or bottom feeds to
7) Siemens standard trim has hidden hinges and mounting
hardware for added safety. The rounded door corners not only
enhance the panel’s appearance but also help to eliminate
injuries caused from sharp corners.
3
8) Semi-flush lock comes standard. Easily identified locked position
denoted by keyway being horizontal when door has been locked.
4
2
5
7
1
6
6
6
www.sydist.com
www.sydist.com/SiemensMurray
8
Catalog Numbering System
Unassembled Panelboards
Type P1 unassembled panelboards are
completely convertible from main lug
to main breaker and vice-versa.
Additionally feed-thru lugs, or subfeed
circuit breakers up to 400 ampere can
be added without increasing the box
height for Revised P1 with “T” suffix,
see the chart.
Note: Main/Subfeed Breaker mounting
kits may be ordered with or without
breakers included, see page 5
and 6 for selection.
4. List required branch circuit
breakers and filler plates to cover
any unused positions.
5. Select any modifications
or accessories.
1. Compute total number of poles to
determine interior catalog number.
(Note: BL / BQD (or) xGB Main Breaker
will use unit space. The total number of
poles should include 2 (or) 3 poles for
1-phase (or) 3-phase mains.)
2. List catalog number and price of
interior, box and front.
3. Select main lug kit or main breaker
kit from appropriate tables.
Note: Revised P1 was introduced in June 2014. All original P1 devices do not include the "Subfeed Space" Indicator.
All original P1 included the Subfeed Space as standard.
P 1 X 1 8 MC 2 5 0 A T
Type of Panel
P1
Voltage and System
X = 208Y/120, 3-Phase 4-Wire
A = 120/240V, 1-Phase 3-Wire
E = 480Y/277V, 3-Phase 4-Wire
7 = xGB interior, 480Y/277V, 3-Phase 4-Wire
Circuits
18, 30, 42, 54* (*Revised P1 only)
Mains MC = Convertible mains
Select Main Lug Kit or Breaker Mounting Kit from page ?
Amperage
400A max (typically 250A or 400A)
Main Bus Material
A = Aluminum
C = Copper
Subfeed Space Indicator (for Revised P1 only)
T = Subfeed Space Included
Note: Standard bussing in P1 panels is tin plated for aluminum and copper.
Standard bus is temperature rated to the maximum amperage in the panel.
Branch Breakers
Panel Type
P1, Revised P11
Voltage (Max.)
240
480 / 277
600 / 347 3
Breaker Type
BL, BLH, HBL, BQD, NGB, HGB, LGB
BQD, NGB, HGB, LGB,
BQDG 2, NGB, HGB, LGB
Additional Information
See Page 17
1 ConsultsalesofficeforavailabilityofCSA.
2 See Speedfax for additional information.
3 600/347V options are not available in a UPB panel - see factory assembled section.
www.sydist.com www.sydist.com/SiemensMurray
7
Distributor Stock
Type P1 Panelboards
Pricing An Unassembled Panel
400A Max. — 20" Wide x 5.75" Deep
1. Choose the appropriate Interior from the
table below.
2. Choose the Main Device: Main Lugs from page
16, Main Breaker Kit from pages 16 - 17 and
Main Breakers from Section 7.
3. Choose Branch Breakers. BL, BQD and xGB
breakers from Section 7.
4. Choose Feed-Thru Lugs or Subfeed Breaker
Kit from pages 16 - 17 and Subfeed
Breaker from Section 7.
Type P1 Unassembled Panelboards (Revised P1 introduced 2014)
Amps
Max. # of
Poles
Original Interior
Catalog Number
Box Size
Type 1
Encl.
Type 3R/12
Encl.
Type 1 Front
Surface
Type1 Front
Flush
P1A18MC250AT
P1A30MC250AT
P1A42MC250AT
P1A54MC250AT
—
P1A30MC400AT
P1A42MC400AT
P1A54MC400AT
P1A18MC250CT
P1A30MC250CT
P1A42MC250CT
P1A54MC250CT
—
P1A30MC400CT
P1A42MC400CT
P1A54MC400CT
32
38
44
50
—
62
68
74
32
38
44
50
—
62
68
74
B32
B38
B44
B50
—
B62
B68
B74
B32
B38
B44
B50
—
B62
B68
B74
WP32
WP38
WP44
WP50
—
WP62
WP68
WP74
WP32
WP38
WP44
WP50
—
WP62
WP68
WP74
S32B
S38B
S44B
S50B
—
S62B
S68B
S74B
S32B
S38B
S44B
S50B
—
S62B
S68B
S74B
F32B
F38B
F44B
F50B
—
F62B
F68B
F74B
F32B
F38B
F44B
F50B
—
F62B
F68B
F74B
P1X18MC250AT
P1X30MC250AT
P1X42MC250AT
P1X54MC250AT
—
P1X30MC400AT
P1X42MC400AT
P1X54MC400AT
P1X18MC250CT
P1X30MC250CT
P1X42MC250CT
P1X54MC250CT
—
P1X30MC400CT
P1X42MC400CT
P1X54MC400CT
32
38
44
50
—
62
68
74
32
38
44
50
—
62
68
74
B32
B38
B44
B50
—
B62
B68
B74
B32
B38
B44
B50
—
B62
B68
B74
WP32
WP38
WP44
WP50
—
WP62
WP68
WP74
WP32
WP38
WP44
WP50
—
WP62
WP68
WP74
S32B
S38B
S44B
S50B
—
S62B
S68B
S74B
S32B
S38B
S44B
S50B
—
S62B
S68B
S74B
F32B
F38B
F44B
F50B
—
F62B
F68B
F74B
F32B
F38B
F44B
F50B
—
F62B
F68B
F74B
P1E18MC250AT
P1E30MC250AT
P1E42MC250AT
P1E54MC250AT
—
P1E30MC400AT
P1E42MC400AT
P1E54MC400AT
P1E18MC250CT
P1E30MC250CT
P1E42MC250CT
P1E54MC250CT
—
P1E30MC400CT
P1E42MC400CT
P1E54MC400CT
32
38
44
50
—
62
68
74
32
38
44
50
—
62
68
74
B32
B38
B44
B50
—
B62
B68
B74
B32
B38
B44
B50
—
B62
B68
B74
WP32
WP38
WP44
WP50
—
WP62
WP68
WP74
WP32
WP38
WP44
WP50
—
WP62
WP68
WP74
S32B
S38B
S44B
S50B
—
S62B
S68B
S74B
S32B
S38B
S44B
S50B
—
S62B
S68B
S74B
F32B
F38B
F44B
F50B
—
F62B
F68B
F74B
F32B
F38B
F44B
F50B
—
F62B
F68B
F74B
P1718MC250AT
P1730MC250AT
P1742MC250AT
P1754MC250AT
—
P1730MC400AT
P1742MC400AT
P1754MC400AT
P1718MC250CT
P1730MC250CT
P1742MC250CT
P1754MC250CT
—
P1730MC400CT
P1742MC400CT
P1754MC400CT
32
38
44
50
—
62
68
74
32
38
44
50
—
62
68
74
B32
B38
B44
B50
—
B62
B68
B74
B32
B38
B44
B50
—
B62
B68
B74
WP32
WP38
WP44
WP50
—
WP62
WP68
WP74
WP32
WP38
WP44
WP50
—
WP62
WP68
WP74
S32B
S38B
S44B
S50B
—
S62B
S68B
S74B
S32B
S38B
S44B
S50B
—
S62B
S68B
S74B
F32B
F38B
F44B
F50B
—
F62B
F68B
F74B
F32B
F38B
F44B
F50B
—
F62B
F68B
F74B
Revised P1 Interior
Catalog Number
Convertible Mains — 1-Phase, 3-Wire 120/240V
250
400
250
400
18
30
42
54
18
30
42
54
18
30
42
54
18
30
42
54
P1A18MC250A
P1A30MC250A
P1A42MC250A
P1A18MC400A
P1A30MC400A
P1A42MC400A
P1A18MC250C
P1A30MC250C
P1A42MC250C
P1A18MC400C
P1A30MC400C
P1A42MC400C
Convertible Mains — 3-Phase, 4-Wire 208Y/120V
250
400
250
400
18
30
42
54
18
30
42
54
18
30
42
54
18
30
42
54
P1X18MC250A
P1X30MC250A
P1X42MC250A
P1X18MC400A
P1X30MC400A
P1X42MC400A
P1X18MC250C
P1X30MC250C
P1X42MC250C
P1X18MC400C
P1X30MC400C
P1X42MC400C
Convertible Mains — 3-Phase, 4-Wire 480Y/277V
250
400
250
400
18
30
42
54
18
30
42
54
18
30
42
54
18
30
42
54
P1E18MC250A
P1E30MC250A
P1E42MC250A
P1E18MC400A
P1E30MC400A
P1E42MC400A
P1E18MC250C
P1E30MC250C
P1E42MC250C
P1E18MC400C
P1E30MC400C
P1E42MC400C
Interiors for xGB Breakers — 3-Phase, 4-Wire 480Y/277V
250
400
250
400
18
30
42
54
18
30
42
54
18
30
42
54
18
30
42
54
P1718MC250A
P1730MC250A
P1742MC250A
P1718MC400A
P1730MC400A
P1742MC400A
P1718MC250C
P1730MC250C
P1742MC250C
P1718MC400C
P1730MC400C
P1742MC400C
42 circuit with Back-fed Main
54 circuit 400A

Front included in NEMA 3R and 3R/12 Box.
8
8
www.sydist.com
www.sydist.com/SiemensMurray
Product Category UPB
Distributor Stock
Type P1 Panelboards
Lug Kits — Main or Feed Thru
Amp
Wire Range
Rating Matl. (includes Neutral)
AL
250
CU
AL
400
CU
400
AL
Service
1 Phase
3 Phase
1 Phase
(1) #6 AWG350 kcmil (CU or AL)
3 Phase
1 Phase
(2) 1/0 - 250 kcmil
or (1) #2 AWG-600 kcmil 3 Phase
1 Phase
(2) 1/0 - 4/0
or (1) 1/0 - 600 kcmil
3 Phase
1 Phase
AL 1/0-750 kcmil
(max. 600 kcmil CU wire) 3 Phase
(1) #6 AWG350 kcmil (CU or AL)
Original
Catalog
Number
MLKA1
MLKA3
MLKC1
MLKC3
4MLKA1
4MLKA3
4MLKC1
4MLKC3
–
–
Revised P1
Catalog
Number
MLKA1A
MLKA3A
MLKC1A
MLKC3A
4MLKA1A
4MLKA3A
4MLKC1A
4MLKC3A
4MLKA1B
4MLKA3B
MBKFD3A
Breaker Mounting Kits — Main or Subfeed Strap Kit w/o Breaker
Ampere
Rating
100A
Breaker Types
BQD
100A
BL, BLH, HBL
125A
NGB, HGB, LGB
125A
ED4, ED6, HED4, HED6
225A
QJ2, QJH2, QJ2-H
250A
FXD6, FD6, HFD6, HFXD6
400A
JXD2, JD6, JXD6,
HJD6, HJXD6

 400
Service
3-Phase
1-Phase
3-Phase
1-Phase
3-Phase
1-Phase
3-Phase
1-Phase
3-Phase
1-Phase
3-Phase
1-Phase
3-Phase
Original P1
Catalog
Number
MBKBC3
MBKBL1
MBKBL3
MBKNB1
MBKNB3
MBKED1
MBKED3
MBKQJ1
MBKQJ3
MBKFD1
MBKFD3
MBKJD1
MBKJD3
amp kit is for main only — not allowed for subfeed breaker.
 Back-fed main occupies branch space.
Copper Neutral Lug Kits — 250A
Number
of Circuits Description
18
30
42
54, 66
2 or 4 Branch Neutral Strips,
1 Main Neutral Lug, Hardware
2/0 Neutral Lug Kits — 250A and 400A
18
30
42
54, 66
2 or 4 Branch Neutral Strips,
1 Main Neutral Lug, Hardware
200% Neutral Lug Kits/250A
18
30
42
54, 66
2 or 4 Branch Neutral Strips,
1 Main Neutral Lug, Hardware
200% Neutral Lug Kits/400A
18
30
42
54, 66

2 or 4 Branch Neutral Strips, 1 Main
600MCM Neutral Lug, Hardware
Replacement Parts Only
Revised P1
Catalog
Number
Use Back-fed
Main Label
Kit # MBKBFA
(includes Neutral
Lug, "MAIN" label
and instructions)
MBKQJ3A
MBKED1A
MBKED3A
MBKQJ1A
MBKQJ3A
MBKFD1A
MBKFD3A
MBKJD1A
MBKJD3A
Miscellaneous Parts and Accessories
Original P1
Catalog
Number
Revised P1
Catalog
Number
CNKL18
CNKL30
CNKL42
—
Use 30 ckt kit
CNLK30A
CNLK42A
CNLK54A
—
—
—
—
Use 30 ckt kit
LNLK30A
LNLK42A
LNLK54A
Catalog #
BK1
BK1A
BK2
BK3
IMK1
11-1824-01
12-1110-01
11-1056-01
NBK03
NBK04
NBK05
2NLK18
2NLK30
2NLK42
—
Use 30 ckt kit
2NLK30A
2NLK42A
2NLK54A
42NLK18
42NLK30
42NLK42
—
Use 30 ckt kit
42NLK30A
42NLK42A
42NLK54A
NBK06
EGK
ECGK
IGK
ICGK
EWK1
EWK2
EBF1
P1SCRWS
DFFP1
P1CONBPHCU 
P1CONBPHAL 
P1CONACPHCU 
P1CONACPHAL 
Product Category UPB
Description
Bonding Kit for 250A max. Original P1 Panels
Bonding Kit for 250A max. Revised P1 Panels
Bonding kit for S1/S2 400 & 600
Bonding kit
Interior Adjusting Kit
Directory Card Holder
Directory Card
NEMA Instruction Book
Number Strips 1–42 . Stick-on type;
Use w/ P1 series Panels
Number Strips 43–84. Stick-on type;
Use w/ P1 series Panels
Number Strips 85–126. Stick-on type;
Use w/ P1 series Panels
Number Strips 127–168. Stick-on type;
Use w/ P1 series Panels
AL Ground Bus 44 Connections
CU Ground Bus 44 Connections
Insulated AL Ground Bus
Insulated CU Ground Bus
End Wall Kit with Knockouts (20" W x 5.75" DP)
End Wall Kit with Knockouts (24" W x 7.75" DP)
NEB/HEB Filler Plate
Package of 42 breaker mounting screws for P1
1" Branch circuit filler plate (suitable for replacing
QF3 in P1 thru P5 Panelboards and Switchboards)
Connector kit – 6 pcs. B-phase Copper
Connector kit – 6 pcs. B-phase Aluminum
Connector kit – 6 pcs. A or C-phase Copper
Connector kit – 6 pcs. A or C-phase Aluminum
www.sydist.com www.sydist.com/SiemensMurray
9
Warehouse Stock/Unassembled
Main Breaker Mounting Kits with Breakers for P1 Panels
(250A and lower can be used as subfeed kits also)
Original P1
Catalog Number
MBKED3100
MBKED3125
MBKQJ1125
MBKQJ1150
MBKQJ1175
MBKQJ1200
MBKQJ1225
MBKQJ3125
MBKQJ3150
MBKQJ3175
MBKQJ3200
MBKQJ3225
MBKQJ1125H
MBKQJ1150H
MBKQJ1175H
MBKQJ1200H
MBKQJ1225H
MBKQJ3125H
MBKQJ3150H
MBKQJ3175H
MBKQJ3200H
MBKQJ3225H
MBKFD3150
MBKFD3175
MBKFD3200
MBKFD3225
MBKFD3250
MBKJD1300
MBKJD3300
MBKJD1400
MBKJD3400
MBKJD12300
MBKJD32300
MBKJD12400
MBKJD32400

Revised P1
Catalog Number
Ratings
Description
MBKED3100A
MBKED3125A
MBKQJ1125A
MBKQJ1150A
MBKQJ1175A
MBKQJ1200A
MBKQJ1225A
MBKQJ3125A
MBKQJ3150A
MBKQJ3175A
MBKQJ3200A
MBKQJ3225A
MBKQJ1125HA
MBKQJ1150HA
MBKQJ1175HA
MBKQJ1200HA
MBKQJ1225HA
MBKQJ3125HA
MBKQJ3150HA
MBKQJ3175HA
MBKQJ3200HA
MBKQJ3225HA
MBKFD3150A
MBKFD3175A
MBKFD3200A
MBKFD3225A
MBKFD3250A
MBKJD1300A
MBKJD3300A
MBKJD1400A
MBKJD3400A
MBKJD12300A
MBKJD32300A
MBKJD12400A
MBKJD32400A
240V
Kit w/3-pole ED4 100A breaker
Kit w/3-pole ED4 125A breaker
Kit w/2-pole QJ2 125A breaker
Kit w/2-pole QJ2 150A breaker
Kit w/2-pole QJ2 175A breaker
Kit w/2-pole QJ2 200A breaker
Kit w/2-pole QJ2 225A breaker
Kit w/3-pole QJ2 125A breaker
Kit w/3-pole QJ2 150A breaker
Kit w/3-pole QJ2 175A breaker
Kit w/3-pole QJ2 200A breaker
Kit w/3-pole QJ2 225A breaker
Kit w/2-pole QJ2H 125A breaker
Kit w/2-pole QJ2H 150A breaker
Kit w/2-pole QJ2H 175A breaker
Kit w/2-pole QJ2H 200A breaker
Kit w/2-pole QJ2H 225A breaker
Kit w/3-pole QJ2H 125A breaker
Kit w/3-pole QJ2H 150A breaker
Kit w/3-pole QJ2H 175A breaker
Kit w/3-pole QJ2H 200A breaker
Kit w/3-pole QJ2H 225A breaker
Kit w/3-pole FXD6 150A breaker
Kit w/3-pole FXD6 175A breaker
Kit w/3-pole FXD6 200A breaker
Kit w/3-pole FXD6 225A breaker
Kit w/3-pole FXD6 250A breaker
Kit w/2-pole JXD6 300A breaker
Kit w/3-pole JXD6 300A breaker
Kit w/2-pole JXD6 400A breaker
Kit w/3-pole JXD6 400A breaker
Kit w/2-pole JXD2 300A breaker
Kit w/3-pole JXD2 300A breaker
Kit w/2-pole JXD2 400A breaker
Kit w/3-pole JXD2 400A breaker
65KA
65KA
10KA
10KA
10KA
10KA
10KA
10KA
10KA
10KA
10KA
10KA
42KA
42KA
42KA
42KA
42KA
42KA
42KA
42KA
42KA
42KA
65KA
65KA
65KA
65KA
65KA
65KA
65KA
65KA
65KA
65KA
65KA
65KA
65KA
480V
18KA
18KA
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
35KA
35KA
35KA
35KA
35KA
35KA
35KA
35KA
35KA
–
–
–
–
Branch Breakers Selection
for P1
Selection Guide
1. Select breaker type.
2. Select required amperage.
3. Select number of poles.
4. Select branch breaker catalog
numbers.
5. Select ground bar and filler
plates. (See replacement parts
& accessories on Page 15.)
300A Main installed.
These Revised P1 kits can now
be used as top or
bottom feed.
Kits are for Main only. New “Revised P1” kits can be used for either top feed or bottom feed.
NOTE: "Revised P1" Kits above only work for interior numbers ending in "T" or "N". Use "Original P1" kits for all others.
AFCI – Combination Type Arc Fault Circuit Interrupter
Interrupting Ratings (kA)
RMS Symmetrical Amperes
BAF
2-pole
Ampere
Rating
15
20
15
20
15
20
15
20
Catalog
Number
B115AFC
B120AFC
B115AFCH
B120AFCH
BA115AFCHH
BA120AFCHH
B215AFC
B220AFC
Volts AC
120
10
10
22
22
65
65
10
10
BAFH
2-pole
15
20
B215AFCH
B220AFCH
22
22
Breaker
Type
BAF2
1-pole
BAFH2
1-pole
HBAF2
1-pole
Switching Neutrals
Breaker
Type
BG
2-Wire
Common Trip
BG
3-Wire
Common Trip
* Built to order.
Ampere
Rating
15
20
30
15
20
30
Catalog
Number
BG215*
BG220*
BG230*
BG315*
BG320*
BG330*
.
Product Category UPB
10 www.sydist.com
10
www.sydist.com/SiemensMurray
120/240
—
—
—
—
—
—
—
240
—
—
—
—
—
—
—
—
—
—
—
—
—
Maximum Interrupting Rating (kA)
120V AC 120/240V AC
240V AC
10
—
—
10
—
—
10
—
—
—
10
—
—
10
—
—
10
—
AFCI – Branch Feeder Type Arc Fault Circuit Interrupter
Interrupting Ratings (kA)
RMS Symmetrical Amperes
Breaker
Type
BAF2
1-pole
BAF2H
1-pole
HBAF2
1-pole
Ampere
Rating
15
20
15
20
15
20
Catalog
Number
BA115AF
BA120AF
BA115AFH
BA120AFH
BA115AFHH
BA120AFHH
Volts AC
120
10
10
22
22
65
65
120/240
—
—
—
—
—
—
240
—
—
—
—
—
—
Dual Function AFCI/GFCI Circuit Breaker
Interrupting Ratings (kA)
RMS Symmetrical Amperes
Breaker
Type
BFGA2
1-pole
BFGAH2
1-pole
HBFGA2
1-pole
Ampere
Rating
15
20
15
20
15
20
Catalog
Number
BA115DF
BA120DF
BA115DFH
BA120DFH
BA115DFHH
BA120DFHH
Volts AC
120
10
10
22
22
65
65
120/240
—
—
—
—
—
—
240
—
—
—
—
—
—
Warehouse Stock / Unassembled
Type P1 Panelboards
Branch Breakers Selection for P1
Selection Guide
1. Select breaker type.
2. Select required amperage.
3. Select number of poles.
4. Select branch breaker catalog numbers.
BL Branch Breakers – 10,000A IR
Amp
Rating
15
20
25
30
35
40
45
50
55
60
70
80
90
100
1-Pole
120/240V
B115
B120
B125
B130
B135
B140
B145
B150
B155
B160
B170
—
—
—
2-Pole
120/240V
B215
B220
B225
B230
B235
B240
B245
B250
—
B260
B270
B280
B290
B2100
2-Pole
240V
B215R
B220R
B225R
B230R
B235R
B240R
B245R
B250R
—
—
—
—
—
—
HBL Branch Breakers – 65,000A IR
Amp
Rating
15
20
30
40
50
60
70
80
90
100
1-Pole
120/240V
B115HH
B120HH
B130HH
B140HH
B150HH
—
—
—
—
—
2-Pole
120/240V
B215HH
B220HH
B230HH
B240HH
B250HH
B260HH
B270HH
B280HH
B290HH
B2100HH
3-Pole
240V
B315
B320
B325
B330
B335
B340
B345
B350
—
B360
B370
B380
B390
B3100
3-Pole
240V
B315HH
B320HH
B330HH
B340HH
B350HH
B360HH
B370HH
B380HH
B390HH
B3100HH
GFCI Personnel Protection (5MA)
Interrupting Ratings (kA)
RMS Symmetrical Amperes
Breaker
Type
BLF
1-Pole
BLF
2-Pole
BLHF
1-Pole
BLHF
2-Pole
Ampere
Rating
15
20
25
30
15
20
30
40
50
60
15
20
30
15
20
30
40
50
60
Catalog
Number
BF115
BF120
BF125
BF130
BF215
BF220
BF230
BF240
BF250
BF260
BF115H
BF120H
BF130H
BF215H
BF220H
BF230H
BF240H
BF250H
BF260H
Volts AC
120
10
10
10
10
—
—
—
—
—
—
22
22
22
—
—
—
—
—
—
120/240
—
—
—
—
10
10
10
10
10
10
—
—
—
22
22
22
22
22
22
240
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
5. Select ground bar and filler plates.
(See replacement parts & accessories
on Pages 17 and 18.)
BLH Branch Breakers – 22,000A IR
Amp
Rating
15
20
25
30
40
50
55
60
70
80
90
100
1-Pole
120/240V
B115H
B120H
B125H
B130H
B140H
B150H
B155H
B160H
B170H
—
—
—
2-Pole
120/240V
B215H
B220H
B225H
B230H
B240H
B250H
—
B260H
B270H
B280H
B290H
B2100H
3-Pole
240V
B315H
B320H
B325H
B330H
B340H
B350H
—
B360H
B370H
B380H
B390H
B3100H
BQD Branch Breakers – 14,000A IR Max. @ 480/277 Vac /
65,000A IR max. @ 240 Vac
Amp
Rating
15
20
25
30
35
40
45
50
60
70
80
90
100
1-Pole
277V
BQD115
BQD120
BQD125
BQD130
BQD135
BQD140
BQD145
BQD150
BQD160
BQD170
BQD180
BQD190
BQD1100
2-Pole
480Y/277V
BQD215
BQD220
BQD225
BQD230
BQD235
BQD240
BQD245
BQD250
BQD260
BQD270
BQD280
BQD290
BQD2100
3-Pole
480Y/277V
BQD315
BQD320
BQD325
BQD330
BQD335
BQD340
BQD345
BQD350
BQD360
BQD370
BQD380
BQD390
BQD3100
GB Family Branch Breakers
NGB –
25,000 A IR Max. @ 480/277V AC / 100,000 A IR @ 240V AC
HGB – 35,000 A IR Max. @ 480/277V AC / 100,000 A IR @ 240V AC
LGB – 65,000 A IR Max. @ 480/277V AC / 100,000 A IR @ 240V AC
Amp
Rating
15
20
25
30
35
40
45
50
60
70
80
90
100
110
125
1-pole
277V
xGB1B015B
xGB1B020B
xGB1B025B
xGB1B030B
xGB1B035B
xGB1B040B
xGB1B045B
xGB1B050B
xGB1B060B
xGB1B070B
xGB1B080B
xGB1B090B
xGB1B100B
xGB1B110B
xGB1B125B
2-pole
480Y/277V
xGB2B015B
xGB2B020B
xGB2B025B
xGB2B030B
xGB2B035B
xGB2B040B
xGB2B045B
xGB2B050B
xGB2B060B
xGB2B070B
xGB2B080B
xGB2B090B
xGB2B100B
xGB2B110B
xGB2B125B
3-pole
480Y/277V
xGB3B015B
xGB3B020B
xGB3B025B
xGB3B030B
xGB3B035B
xGB3B040B
xGB3B045B
xGB3B050B
xGB3B060B
xGB3B070B
xGB3B080B
xGB3B090B
xGB3B100B
xGB3B110B
xGB3B125B
Replace x with N, H or L depending on desired type of breaker
NOTE: 2-pole and 3-pole xGB Frame Breakers are also rated at
14,000 A IR max. for 600Y/347V AC systems. UPB interiors
are only rated to 480V max. - see factory assembled section
for proper interiors.
n Built to order. Allow 2–3 weeks for delivery.
 HACR rated.


To add shunt trip to BL breakers, see Speedfax for Breaker Accessories.
To add shunt trip to BQD breakers, see Speedfax for Breaker Accessories.
www.sydist.com www.sydist.com/SiemensMurray
11
Siemens Single-Phase Load Centers
Features and Comparison
www.usa.siemens.com/loadcenters
Features
ES Series
Murray
PL Series
Bussing
AL
AL
CU
Convertible
MB to MLO Only
MB to MLO/MLO to MB
MB to MLO/MLO to MB
Invertible (Indoor)
Yes
Yes
Yes
Insta-Wire Neutrals
Yes
No
Yes
Outboard Neutrals
No
Yes
No
High-Circuitry
Yes
Yes
Yes
Trim Mount Tabs
Yes
Yes
Yes
Packaging
Single-Carton
Carton-in-Carton
Carton-in-Carton
Breakers
Siemens
Siemens or Murray
Siemens
12
12 www.sydist.com
www.sydist.com/SiemensMurray
Siemens PL Series Load Centers™
Features and Benefits
www.usa.siemens.com/loadcenters
All devices convertible from main
lug to main breaker and vice versa.
Invertible for bottom
feed application.
Mounting tabs on the
trim hold it in place on
the load center, freeing
up both hands to drive
the trim screws.
All devices are
provided with 2
factory installed
ground bars.
The pre-positioned bond
screw eliminates bond
strap/screw assemblies,
and reduces the risk of
losing components in
the field.
Combination
head screw on the
neutrals, ground,
trim, upper pan,
and bond screw
provide installation
flexibility.
The patented INSTAWIRE™ neutral/
ground system allows
for faster installation
because screws are
backed out, ready for
wire insertion. The
visible neutral and grounds system aids in
the insertion of conductors.
A rigid, sturdy base
pan provides the
ruggedness required
for the most harsh
applications.
Copper bus
The outdoor
enclosure has a
slide hinge door
for the easiest
installation and
can be removed
by backing out
only one screw.
PL Series Load
Centers ship with
trims packaged
separately.
www.sydist.com www.sydist.com/SiemensMurray
13
PL™ Series Load Centers
1-Phase Main Lug and Main Breaker Load Centers
1-Phase, 3-Wire SN, 120/240 Volts Ac
Main Breaker/Convertible Load Centers

g
Copper Bus
12-70 Circuits / 100-225 Amperes
Branch Circuits
No. Of
Amp Rating Spaces
No. Of
Circuits

60/75°C Rated 22,000A IR
Indoor Enclosure – Nema Type 1
Outdoor Enclosure – Nema Type 3R
Enclosure Height
Enclosure Height
Catalog Number
(Inches)
Catalog Number
(Inches) 
100
12
24
P1224B1100CU
18
PW1224B1100CU
21
100
16
24
P1624B1100CU
21
PW1624B1100CU
23
100
20
20
P2020B1100CU
24
PW2020B1100CU
27
100
20
24
P2024B1100CU
24
—
—
100
24
24
P2424B1100CU
24
—
—
100
30
30
P3030B1100CU
30
—
—
100
30
40
—
—
PW3040B1100CU
35
125
30
30
P3030B1125CU
30
PW3040B1125CU
35
150
20
30
P2030B1150CU
24
—
—
150
20
30
—
—
PW2030B1150CU
27
150
30
30
P3030B1150CU
30
—
—
150
30
40
—
—
PW3040B1150CU
35
200
20
40
P2040B1200CU
30
PW2040B1200CU
27
200
30
40
P3040B1200CU
36
PW3040B1200CU
35
200
30
40
P3040B1200
36
—
—
200
40
40
P4040B1200CU
36
PW4040B1200CU
38
200
40
40
P4040B1200
36
—
—
200
54
70
P5470B1200CU
44
—
—
225
42
60
P4260B1225CU
39
PW4260B1225CU
42
225
54
70
P5470B1225CU
44
—
—
Single phase factory installed 22kA IR main circuit breaker offers 22/10kA IR series combination rating when using 10kA
type QP, QT, QPF, QE, QN, and QAF/QAFC branch breakers.

g
Main Lug/Convertible Load Centers
Copper Bus
12-70 Circuits / 125-225 Amperes
60/75° Rated 100,000A IR
Branch Crcuits
No. Of
Amp Rating Spaces
No. Of
Circuits
Indoor Enclosure - Nema Type 1
Outdoor Enclosure - Nema Type 3R
Enclosure Height
Enclosure Height
Catalog Number
(Inches) 
Catalog Number
(Inches) 
125
125
125
125
125
125
125
125
150
200
200
200
200
200
200
200
200
200
225
225
225
12
24
24
20
24
40
40
40
30
24
40
40
30
40
40
54
40
40
24
60
70
P1212L1125CU 
P1224L1125CU 
P1624L1125CU
P2020L1125CU
P2024L1125CU
P2440L1125CU
P3040L1125CU
P4040L1125CU
P2030L1150CU
P1224L1200CU
P2040L1200CU
P2440L1200CU
P3030L1200CU
P3040L1200CU
P3040L1200 
P3054L1200CU
P4040L1200CU
P4040L1200 
—
P4260L1225CU
P5470L1225CU





12
12
16
20
20
24
30
40
20
12
20
24
30
30
30
30
40
40
12
42
54
Suitable for use as service equipment.
May be installed on higher rated systems when protected
by a circuit breaker with a higher AIR rating.
Indoor enclosures are 14 1/4" wide by 3 7/8" deep.
Outdoor enclosures are 14 1/2" wide by 4 1/4" deep.
Suitable for use as service entrance equipment when not
more than six main disconnecting means are provided. See
article 230.71 of the NEC®.
14
14 www.sydist.com
www.sydist.com/SiemensMurray

g

18
18
21
24
24
24
30
36
24
24
30
30
36
36
36
36
36
36
—
39
44
PW1212L1125CU 
PW1224L1125CU 
PW1624L1125CU
—
—
—
PW3040L1125CU
—
PW2030L1150CU
PW1224L1200CU 
PW2040L1200CU
—
—
PW3040L1200CU
—
PW3054L1200CU
PW4040L1200CU
—
PW1224L1225CU
PW4260L1225CU
—
21
21
23
—
—
—
35
—
27
23
27
—
—
35
—
35
38
—
23
42
—
125A load centers will accept MBK100A and MBK125A.
150A load centers will accept MBK150A. 200A load centers
will accept MBK200A and MBK150A. 225A load centers will
accept MBK225A, MBK200A, MBK150A.
Copper bus load centers are recommended for those applications where the environment may be severe (i.e. far and
coastal areas).
Includes all PL Series features with aluminum
bussing.
Offering a full line of load centers, Siemens
meets the needs of every application and all of
your installation needs. From small load
centers, riser panels and three phase load
centers, to the PL and ES Series Load
Centers™, Siemens has the highest quality,
most complete offering on the market.
Focusing on reliability, value and labor
savings - Siemens is committed to increase
productivity by reducing installation times.
ES and PL Series
Load Center Video
Load Center
Mobile Webpage
PL™ Series Load Centers
1-Phase Special Load Centers
1-Phase, 3-Wire SN, 120/240 Volts AC
Split Ground Series Main Lug Convertible Load Centers
12-60 Circuits / 125-200 Amperes
Copper Bus
60/75° Rated, 100,000A IR
Branch Circuits
Amp
Rating
No. Of
Spaces
No. Of
Circuits
Indoor Enclosure – Nema Type 1
Enclosure Height
Catalog Number
(Inches)
125
125
125
125
150
200
200
200
200
225
12
16
20
24
20
30
30
40
40
40
24
24
30
30
30
40
40
40
40
60
P1224L1125CUSG
P1624L1125CUSG
P2030L1125CUSG
P2430L1125CUSG
P2030L1150CUSG
P3040L1200CUSG
P3040L1200SG
P4040L1200CUSG
P4040L1200SG
P4260L1225CUSG
18
21
24
24
24
36
36
36
36
39
Split Ground Series Main Breaker
Convertible Load Centers
Split Ground Load Centers
have factory installed 100%
neutral with factory bonded
75% ground. No neutral
tie strap.
Copper Bus

40 Circuits / 200 Amperes
60/75° Rated, 22,000A IR
Branch Circuits
Amp
Rating
No. Of
Spaces
No. Of
Circuits
Indoor Enclosure – Nema Type 1
Enclosure Height
Catalog Number
(Inches)
200
40
40
P4040B1200CUSG
36
Outdoor Trailer Panels
Copper Bus

16 Circuits / 200 Amperes
60/75° Rated, 22,000A IR
Amp
Rating
No. Of
Spaces
No. Of
Circuits
Catalog Number
Main Breaker
200
8
16
PW0816L1200TC
MBK150A or
MBK200A
Field Installed
23
200
8
16
PW0816B1200TC
MBK200A
Factory Installed
23

Enclosure Height
(Inches)
g
Load Centers with White Trim
Copper or Aluminum Bus
40 Circuits / 200 Amperes
60/75° Rated 22,000A IR
Branch Circuits
Indoor Enclosure - Nema Type 1
Amp Rating
Main Lug /
Main Breaker
No. Of Spaces
No. Of Circuits
Catalog Number
Enclosure Height
(Inches) 
200
200
200
Main Breaker
Main Breaker
Main Breaker
30
40
40
40
40
40
P3040B1200W
P4040B1200W
P4040B1200CUW
36
36
36






g
Includes all PL Series features with aluminum
bussing.
Indoor enclosures are 14 1/4" wide by 3 7/8" deep.
May be installed on higher rated systems when protected
by a circuit breaker with a higher AIR rating.
Outdoor enclosures are 14 1/2" wide by 4 1/4" deep.
Main lug panel rated 100,000A IR.
Load centers with white trim have increased lead time of
3-4 weeks. Sold in pallet quantites only.
Load centers with CUW suffix indicates copper bus with
white trim. Load centers with W suffix only indicates
aluminum bus with white trim.
Offering a full line of load centers,
Siemens meets the needs of every
application and all of your
installation needs. From small load
centers, riser panels and three
phase load centers, to the PL and
ES Series Load Centers™, Siemens
has the highest quality, most
complete offering on the market.
Focusing on reliability, value and
labor savings - Siemens is
committed to increase productivity
by reducing installation times.
ES and PL Series
Load Center Video
Load Center
Mobile Webpage
www.sydist.com www.sydist.com/SiemensMurray
15
PL™ Series Load Centers
3-Phase Main Lug and Main Breaker Load Centers
3-Phase, 3-Wire, 240 Volt AC or 3-Phase, 4-Wire,
120/240 or 120/208 Volts AC

Main Breaker/Convertible Load Centers
Copper Bus
30-70 Circuits / 100-225 Amperes
60/75°C Rated 22,000A IR
Branch Circuits
Amp
No. Of
Rating
Spaces
No. Of
Circuits
Indoor Enclosure – Nema Type 1
Outdoor Enclosure – Nema Type 3R
Enclosure Height
Enclosure Height
Catalog Number
(Inches) 
Catalog Number
(Inches) 
100
100
125
150
150
200
200
225
225
225
24
42
30
42
42
54
60
60
60
70
P1224B3100CU
P3042B3100CU
P3030B3125CU
P2442B3150CU
P4242B3150CU
P3054B3200CU
P4260B3200CU
P4260B3225CU
P4260B3225TCU
P5470B3225CU
12
30
30
24
42
30
42
42
42
54
24
30
39
36
42
39
42
42
49
49
—
—
—
—
—
PW3054B3200CU
PW4260B3200CU
—
—
—
—
—
—
—
—
38
42
—
—
—


Main Lug/Convertible Load Centers
Copper Bus

12-70 Circuits / 125-225 Amperes
60/75° Rated 100,000A IR
Branch Circuits
Amp
No. Of
Rating
Spaces
No. Of
Circuits
Indoor Enclosure – Nema Type 1
Enclosure Height
Catalog Number
(Inches)
Outdoor Enclosure – Nema Type 3R
Enclosure Height
Catalog Number
(Inches)
125
200
200
225
225
24
42
54
60
70
P1224L3125CU g
P2442L3200CU
P3054L3200CU
P4260L3225CU
P5470L3225CU
PW1224L3125CU g
PW2442L3200CU
PW3054L3200CU
PW4260L3225CU 
—





12
24
30
42
54
May be installed on higher rated systems when protected
by a circuit breaker with a higher AIR rating.
Back fed main breaker.
Indoor enclosures are 14 1/4" wide by 3 7/8" deep.
Outdoor enclosures are 14 1/2" wide by 4 1/4" deep.
Suitable for use as service entrance equipment when not
more than six main disconnecting means are provided. See
article 230.71 of the NEC®.

21
36
39
42
49

g



21
35
38
42
—
Includes factory installed feed through lugs and is also
non-convertible.
Non-convertible to main breaker.
All load centers are provided with tin plated copper bus
bars.
Rated 100,000A IR in series with breakers listed on
wiring diagram.
All load centers are provided with tin-plated copper
bus bars.
Offering a full line of load centers, Siemens
meets the needs of every application and all of
your installation needs. From small load
centers, riser panels and three phase load
centers, to the PL and ES Series Load
Centers™, Siemens has the highest quality,
most complete offering on the market.
Focusing on reliability, value and labor
savings - Siemens is committed to increase
productivity by reducing installation times.
ES and PL Series
Load Center Video
Load Center
Mobile Webpage
16 www.sydist.com
16
www.sydist.com/SiemensMurray
Rock Solid Load Centers
Features
The Murray Rock Solid Load Center is the highest quality, most
versatile design in the industry. Features on the Rock Solid Load
Center include:
1. "Swiss Cheese" style neutral bars provide multiple 1/0
connection points.
1
2. All units include factory installed ground bar and isolated
neutral.
3. With the use of the included bonding strap, ground bars and
neutral bars can be bonded for service entrance applications.
4. Outboard neutral and groundbars allow for all neutral and
ground connections to be located away from breaker
connections, making for a neat, clean installation.
2
4
5. Mounting tabs on the trim hold it in place on the load center,
freeing up both hands to drive the trim screws.
6. Combination head screw on trim and upper pan screws
provide installation flexibility.
7. All devices are convertible from main lug to main breaker or
vice versa with the addition of main breaker or main lug kits.
8. All main breakers are straight in wired – no back feeding
required.
3
5
11. All indoor Rock Solid Load Centers are invertible for bottom
feed applications.
7
8
The following offering is available in the Murray line:
9
10
9. A rigid, sturdy base pan with metal hook rails provides the
most rugged breaker connection in the industry.
10. The outdoor enclosure has a slide hinge door for the easiest
of installation and can be removed by backing out only one
screw.





12-60 Circuits/Spaces
Indoor and outdoor enclosures
100 to 225 Amp
Main lug and main breaker
Value packs - a mix of branch breakers provided with the
load center
11
www.sydist.com www.sydist.com/SiemensMurray
17
Rock Solid Load Centers
Main Lug Only, 1Ø, 65,000 AIC, Main Lug Panels
3-Wire 120/240V AC or 208Y/120V AC, Insulated
and Bonded Split Neutrals
Load centers on this page through
225 amp feature a split neutral insulated bars. For service entrance applications,
install bonding strap, and use both bars for neutral and ground conductors.
For non service entrance applications, do not install bonding strap and use
insulated bars for neutral conductors and bonded bar for ground conductors.
LW2040L1200
12-42 Circuit, 125–225 Amperes
Amps
Max.
125
125
125
125
150
150
200
200
200
200
200
225
No. of
Spaces
12
16
20
30
16
24
12
20
24
30
40
40
Max.
Circuit
24
32
40
40
32
40
24
40
40
40
40
60
Indoor Type 1
Catalog Number
LC1224L1125
LC1632L1125
LC2040L1125
LC3040L1125
LC1632L1150
LC2440L1150
—
LC2040L1200
LC2440L1200
LC3040L1200
LC4040L1200
LC4060L1225
Dimensions
Height
Width
21
143⁄8
21
143⁄8
24
143⁄8
30
143⁄8
24
143⁄8
30
143⁄8
—
—
30
143⁄8
30
143⁄8
36
143⁄8
39
143⁄8
39
143⁄8
Depth
4
4
4
4
4
4
—
4
4
4
4
4
Outdoor Type 3R
Catalog Number
LW1224L1125
LW1632L1125
LW2040L1125
—
—
—
LW1224L1200
LW2040L1200
—
LW3040L1200
—
—
Dimensions
Height
Width
20
141⁄4
29
141⁄4
29
141⁄4
—
—
—
—
—
—
29
141⁄4
29
141⁄4
—
—
38
141⁄4
—
—
—
—
Depth
41⁄2
41⁄2
41⁄2
—
—
—
41⁄2
41⁄2
—
41⁄2
—
—
Max.
Circuit
40
40
40
40
24
42
Indoor Type 1
Catalog Number
LC2040L1125CU
LC2040L1200CU
LC3040L1200CU
LC4040L1200CU
—
LC4242L1225CU
Dimensions
Height
Width
24
143⁄8
30
143⁄8
36
143⁄8
39
143⁄8
—
—
42
143⁄8
Depth
4
4
4
4
—
4
Outdoor Type 3R
Catalog Number
—
—
—
—
LW1224L1225CU
LW4242L1225CU
Dimensions
Height
Width
—
—
—
—
—
—
—
—
29
141⁄4
42
141⁄4
Depth
—
—
—
—
41⁄2
41⁄2
Copper Bus
Amps
Max.
125
200
200
200
225
225
No. of
Spaces
20
20
30
40
12
42
 Convertible
to main breaker by using the following main
breaker kits:
100A load centers: MBK100M only.
125A load centers: MBK100M and MBK125M only.
150A load centers: MBK150M only.
200A load centers: MBK150M and MBK200M only.
225A load centers: MBK150M, MBK200M, and MBK225M
only.
 100-225A only.
 Standard package quantity equal to 1.
18
18 www.sydist.com
www.sydist.com/SiemensMurray
 Dimensions
shown are representative of outside box length,
width & depth (± 18⁄ ”) and do not include allowance for
mounting bumps, endwalls, hubs or hardware protrusions.
Allow approximately 114⁄ ” additional in length and width
dimensions for surface or combination overhang. Consult
factory for specific details if required.
 Hub provision only. Closure plate included. Panels through
225A require HS type hub; panels over 225A require HV type
hub. See accessories page <?> for hub selection.
 Copper bus load centers are recommended for those
applications where the environment may be severe
(ie farm and coastal areas).
Rock Solid Load Centers
Main Breaker, 1Ø, 22,000 AIC
Load centers on this page through 200 amp feature a new split neutral with one bonded
and one insulated bar. For service entrance applications, install bonding strap, and use both
bars for neutral and ground conductors. For non service entrance applications, do not install
bonding strap and use insulated bar for neutral conductors and bonded bar for ground
conductors.
Load Center Short Circuit Current Rating
Murray load centers have UL recognized short circuit current ratings up to 100,000 Amps,
when used with appropriate main or feeder (remote or internal) overcurrent devices. Load
center ratings are shown below. For load center applications with residential or commercial
metering equipment, refer to the appropriate catalog section.
1Ø, main breaker load centers are Underwriter’s Laboratories Listed for use with 60/75°C
conductors and accept Murray branch circuit breakers which are also UL Listed for use with
60/75°C conductors. Type 3R load centers are furnished with a hub opening closure plate.
LC2040B1200
Load Center Short Circuit Current Rating
Load Center
Short Circuit
Current Rating
10,000 AIC
22,000 AIC
42,000 AIC
65,000 AIC
100,000 AIC
100,000 AIC
Load Center
Main Rating
Internal or Remote
Main or Feeder
Circuit Breaker Type
Any
100/125A
150/200/225A
100/125A
150/200/225A
100/125A
150/200/225A
100/125A
150/200/225A
Any
MP-HT, MQH
MD-H, MQHbd, MPP-HT
MQL
MQL
MP-MT, MPP-MT
MPP-MTc
100A, 300V AC, Class “T” Fuse
200A, 300V AC, Class “T” Fuse
12-42 Circuit, 100-200 Amperes
Amps
Max.
100
100
100
100
100
150
150
150
150
200
200
200
200
200
200
200
200
200
No. of
Spaces
12
16
20
24
30
16
20
24
30
12
16
20
24
30
40
30
40
40
Max.
Circuit
24
32
40
40
40
32
40
40
40
24
32
40
40
40
40
54
40
60
Catalog Number
Dimensions
Indoor Type 1g
LC1224B1100
—
LC2040B1100
LC2440B1100
LC3040B1100
LC1632B1150
LC2040B1150
LC2440B1150
LC3040B1150
—
LC1632B1200
LC2040B1200
LC2440B1200
LC3040B1200
LC4040B1200
LC3054B1200
LC4040B1200
LC4060B1200
Height
18
—
24
24
30
24
30
30
36
—
30
30
30
36
39
36
39
401⁄2
Width
143⁄8
—
143⁄8
143⁄8
143⁄8
143⁄8
143⁄8
143⁄8
143⁄8
—
143⁄8
143⁄8
143⁄8
143⁄8
143⁄8
143⁄8
143⁄8
157⁄8
Depth
4
—
4
4
4
4
4
4
4
—
4
4
4
4
4
4
4
5
Outdoor Type 3Rg
Dimensions
Catalog Number
LW1224B1100
LW1632B1100
—
—
—
—
LW2040B1150
—
—
LW1224B1200
—
LW2040B1200
—
LW3040B1200
LW4040B1200
—
—
—
Height
23
23
—
—
—
—
29
—
—
29
—
29
—
38
38
—
—
—
Width
141⁄4
141⁄4
—
—
—
—
141⁄4
—
—
141⁄4
—
141⁄4
—
141⁄4
141⁄4
—
—
—
Depth
41⁄2
41⁄2
—
—
—
—
41⁄2
—
—
41⁄2
—
41⁄2
—
41⁄2
41⁄2
—
—
—
Copper Bus
Dimensions
Amps
Max.
No. of
Spaces
Max.
Circuit
Indoor Type 1g
Catalog Number
100
20
40
LC2040B1100CU
24
200
20
40
LC2040B1200CU
30
200
30
40
LC3040B1200CU
200
40
40
LC4040B1200CU
 100-225A
only.
information is based on use of 10,000 AIC rated branch
circuit breakers in load center (MP-T, MH-T,
MP-GT, MG). Most series ratings exclude MH-T
above 40 Amp. Consult device wiring diagram for specific
data.
 Remote Only
Types MQH & MQL may be mounted internal in 150-225
amp 3Ø main breaker load centers.
 This
Height
Width
143⁄8
Depth
4
36
143⁄8
143⁄8
39
143⁄8
4
 Dimensions
4
4
shown are representative of outside box length,
width & depth (±18⁄ ”) and do not include allowance for
mounting bumps, endwalls, hubs or hardware protrusions.
Allow approximately 114⁄ ” additional in length and width
dimensions for surface or combination overhang. Consult
factory for specific details if required.
Hub provision only. Closure plate included. Panels through
225A require HS type hub; panels over 225A require HV
type hub.
g Standard
package quantity equal to 1.
bus load centers are recommended for those
applications where the environment may be severe
(ie farm and coastal areas).
 Copper
www.sydist.com www.sydist.com/SiemensMurray
19
Siemens ES Series Load Centers™
Features and Benefits
www.usa.siemens.com/loadcenters
Main breaker convertible to main
lug but main lug not convertible.
Invertible for bottom
feed application.
Ground bar field installed
(select skus with “G”
suffix will have ground
bar factory installed).
The pre-positioned bond
screw eliminates bond
strap/screw assemblies,
and reduces the risk of
losing components in
the field.
Combination
head screw on the
neutrals, ground,
trim, upper pan,
and bond screw
provide installation
flexibility.
The patented INSTAWIRE™ neutral/ground
system allows for faster
installation because
screws are backed out,
ready for wire insertion.
The visible neutral
and grounds system
aids in the insertion of
conductors.
Single side inboard
neutral on 24 circuits and
below; dual on 30 circuits
and above.
A rigid, sturdy
base pan
provides the
ruggedness
required for
the most harsh
applications.
ES Series Load Centers ship in
single piece carton.
The outdoor
enclosure
has a slide
hinge door
for the easiest
installation
and can be
removed by
backing out
only one screw.
20
20 www.sydist.com
www.sydist.com/SiemensMurray
Mounting tabs on
the trim hold it in
place on the load
center, freeing
up both hands
to drive the trim
screws.
Aluminum bus
ES™ Series Load Centers
1-Phase Main Lug and Main Breaker Load Centers
1-Phase, 3-Wire SN, 120/240 Volts AC
Main Breaker/Convertible Load Centers

12-70 circuits / 100-225 amperes
Branch Circuits
Amp
Rating
No. Of Spaces
100
10
100
12
100
16
100
20
100
20
100
30
125
12
125
16
125
16
125
24
125
30
125
30
150
16
150
20
150
24
150
30
150
30
150
40
200
16
200
20
200
24
200
30
200
40
200
54
225
42
225
54
No. Of
Circuits
20
24
24
20
24
30
24
24
32
24
30
40
30
30
30
30
40
40
32
40
40
40
40
70
60
70
Indoor Enclosure – Nema Type 1
Catalog
Enclosure Height
Number
(Inches) 
S1020B1100
18
S1224B1100
18
S1624B1100
21
S2020B1100
24
S2024B1100
24
S3030B1100
30
—
—
S1624B1125
21
—
—
S2424B1125
24
S3030B1125
30
S3040B1125
30
S1630B1150
24
S2030B1150
24
S2430B1150
30
S3030B1150
30
S3040B1150
30
—
—
S1632B1200
24
S2040B1200
30
S2440B1200
30
S3040B1200
36
S4040B1200
36
S5470B1200
44
S4260B1225
39
S5470B1225
44
Main Lug/Non-Convertible Load Centers
12-70 circuits / 125-225 amperes
Branch Circuits
Amp
Rating
No. Of Spaces
125
12
125
12
125
16
125
20
125
20
125
20
125
20
125
24
125
24
125
24
125
30
125
30
125
40
150
20
200
12
200
20
200
24
200
30
200
30
200
30
200
40
225
12
225
42
225
54
No. Of
Circuits
12
24
24
20
20
24
24
24
24
40
40
40
40
30
24
40
40
30
40
54
40
24
60
70
Aluminum Bus
60/75°C rated 22,000A IR

Outdoor Enclosure – Nema Type 3R
Catalog
Enclosure Height
Number
(Inches) 
—
—
SW1224B1100
21
SW1624B1100
23
SW2020B1100
27
—
—
—
—
SW1224B1125
21
—
—
SW2024B1125
27
SW2424B1125
27
—
—
SW3040B1125
35
—
—
—
—
—
—
—
—
SW3040B1150
35
SW4040B1150
38
—
—
SW2040B1200
27
—
—
SW3040B1200
35
SW4040B1200
38
—
—
SW4260B1225
42
—
—
Aluminum Bus
Main Breaker
Main Lug
60/75° rated 100,000A IR
Indoor Enclosure - Nema Type 1
Catalog
Enclosure Height
Number
(Inches) 
S1212L1125 
18
18
S1224L1125 
S1624L1125
21
S2020L1125
21
21
S2020L1125G 
S2024L1125
21
21
S2024L1125G 
S2424L1125
24
24
S2424L1125G 
S2440L1125
24
S3040L1125
30
30
S3040L1125G 
S4040L1125
36
S2030L1150
24
21
S1224L1200 
S2040L1200
24
S2440L1200
30
S3030L1200
30
S3040L1200
30
S3054L1200
30
S4040L1200
36
—
—
S4260L1225
36
S5470L1225
42
Outdoor Enclosure - Nema Type 3R
Catalog
Enclosure Height
Number
(Inches) 
SW1212L1125 
21
SW1224L1125 
21
SW1624L1125
21
—
—
—
—
—
—
—
—
SW2424L1125
27
—
—
—
—
SW3040L1125
29
—
—
—
—
SW2030L1150
27
SW1224L1200 
21
SW2040L1200
27
—
—
—
—
SW3040L1200
35
SW3054L1200
35
SW4040L1200
35
SW1224L1225
23
SW4260L1225
38
—
—
 Suitable for use as service equipment.
 May be installed on higher rated systems when protected by a circuit breaker with a higher AIR rating.
 Indoor enclosures are 14 1/4" wide by 3 7/8" deep.
 Outdoor enclosures are 14 1/2" wide by 4 1/4" deep.
 Suitable for use as service entrance equipment when not more than six main disconnecting means are provided. See article
230.71 of the NEC®.
 ES Series single phase skus with a "G" suffix have ground bar included (factory installed).
Offering a full line of load centers, Siemens
meets the needs of every application and all of
your installation needs. From small load
centers, riser panels and three phase load
centers, to the PL and ES Series Load
Centers™, Siemens has the highest quality,
most complete offering on the market.
Focusing on reliability, value and labor
savings - Siemens is committed to increase
productivity by reducing installation times.
ES and PL Series
Load Center Video
Load Center
Mobile Webpage
www.sydist.com www.sydist.com/SiemensMurray
21
ES™ Series Load Centers
1-Phase Special Load Centers
1-Phase, 3-Wire SN, 120/240 Volts AC
Load Centers With White Trim

Aluminum Bus
16-40 circuits / 100 – 200 amperes
60/75° rated 100,000A IR
Branch Circuits
Amp
Main Lug /
Rating
Main Breaker
No. Of
Spaces
Indoor Enclosure – Nema Type 1
No. Of
Catalog
Circuits
Number
100
16
24
Main breaker
S1624B1100W

Enclosure Height

(Inches)
21
125
Main lug
20
20
S2020L1125W
21
125
Main lug
24
24
S2424L1125W
24
200
Main lug
30
30
S3030L1200W
30
125
Main lug
30
40
S3040L1125W
30
200
Main breaker
40
40
S4040B1200W
Amp Rating Main Breaker
No. Of
Spaces
No. Of
Circuits
Catalog Number
Enclosure Height

(Inches)
200
8
16
SW0816L1200T
23

36
Outdoor Trailer Panels
16 circuits / 200 amperes
200
N/A
MBK200A
8
16
Main Lug /
Amp Rating Main Breaker
No. Of
Spaces
No. Of
Circuits
Catalog Number
Breakers Included
100
Main breaker
20
20
S2020B1100P
(3) Q120, (1) Q230
200
Main breaker
30
40
S3040B1200P
(3) Q120, (1) Q230
200
Main lug
30
40
S3040L1200P
(3) Q120, (1) Q230
200
Main breaker
40
40
S4040B1200P
(3) Q120, (1) Q230
Value Pack Load Centers
SW0816B1200T


23
Aluminum Bus
Split Ground Series Load Centers
30-40 Circuits / 125-200 Amperes
16 circuits / 200 amperes

Aluminum Bus
Branch Circuits
Amp
Main Lug /
Rating
Main Breaker
No. Of
Spaces
No. Of
Circuits
Indoor Enclosure – Nema Type 1
Enclosure Height

Catalog Number
(Inches)
125
Main lug
20
30
S2030L1125SG
21
150
Main breaker
30
30
S3030B1150SG
30
200
Main breaker
40
40
S4040B1200SG
36
 Load centers with white trim have increased lead time of 3-4 weeks. Sold in pallet quantities only.
Additional charge will apply. Contact sales office for details.
 Indoor enclosures are 14 1/4" wide by 3 7/8" deep.
 Breakers are shipped inside a sleeve located inside the load center.
 Outdoor enclosures are 14 1/2" wide by 4 1/4" deep.
 Main breaker rated 22,000A IR.
 Split Ground load centers have factory installed 100% neutral with factory bonded 75% ground.
Offering a full line of load centers,
Siemens meets the needs of every
application and all of your
installation needs. From small load
centers, riser panels and three
phase load centers, to the PL and
ES Series Load Centers™, Siemens
has the highest quality, most
complete offering on the market.
Focusing on reliability, value and
labor savings - Siemens is
committed to increase productivity
by reducing installation times.
22
22 www.sydist.com
www.sydist.com/SiemensMurray
ES and PL Series
Load Center Video
Load Center
Mobile Webpage
ES™ Series Load Centers
3-Phase Main Lug and Main Breaker Load Centers
3-Phase, 3-Wire, 240 Volt AC or 3-Phase, 4-Wire,
120/240 or 120/208 Volts AC
Main Breaker/Convertible Load Centers
Aluminum Bus
30-60 circuits / 100-225 amperes
60/75°C rated 10,000A IR 
Branch Circuits
Amp
No. Of
Rating
Spaces
No. Of
Circuits
Indoor Enclosure – Nema Type 1
Catalog
Enclosure Height
Number
(Inches) 
Outdoor Enclosure – Nema Type 3R
Catalog
Enclosure Height
Number
(Inches) 
100
12
24
S1224B3100 
24
—
—
100
30
30
S3030B3100 
30
—
—
100
30
42
S3042B3100 
30
—
—
150
24
42
S2442B3150
36
SW2442B3150
35
150
42
42
S4242B3150
42
—
—
200
30
54
S3054B3200
39
SW3054B3200
38
200
42
60
S4260B3200
42
SW4260B3200
42
225
42
42
S4242B3225
42
SW4242B3225
42
Main Breaker/Non-Convertible Load Centers 
Aluminum Bus
12-70 circuits / 125-225 amperes
60/75° Rated 100,000A IR g
Branch Circuits
Amp
No. Of
Rating
Spaces
No. Of
Circuits
Indoor Enclosure – Nema Type 1
Catalog
Enclosure Height
Number
(Inches) 
Outdoor Enclosure – Nema Type 3R
Catalog
Enclosure Height
Number
(Inches) 
125
24
S1224L3125
SW1224L3125
12
21
21
150
18
36
S1836L3150
24
SW1836L3150
23
150
24
42
S2442L3150
30
SW2442L3150
27
200
12
24
S1224L3200
21
SW1224L3200
21
200
24
42
S2442L3200
30
SW2442L3200
27
200
30
54
S3054L3200
30
SW3054L3200
35
225
42
60
S4260L3225
36
SW4260L3225
38
225
54
70
S5470L3225
42
—
—
 May be installed on higher rated systems when protected by a circuit breaker with a higher AIR rating.
 Back fed main breaker.
 Indoor enclosures are 14 1/4” wide by 3 7/8” deep.
 Outdoor enclosures are 14 1/2” wide by 4 1/4” deep.
 Non-convertible to main breaker.
 Suitable for use as service entrance equipment when not more than six main disconnecting means are provided. See article 230.71 of the NEC®.
g Rated 100,000A IR in series with breakers listed on wiring diagram.
Offering a full line of load centers,
Siemens meets the needs of every
application and all of your
installation needs. From small load
centers, riser panels and three
phase load centers, to the PL and
ES Series Load Centers™, Siemens
has the highest quality, most
complete offering on the market.
Focusing on reliability, value and
labor savings - Siemens is
committed to increase productivity
by reducing installation times.
ES and PL Series
Load Center Video
Load Center
Mobile Webpage
www.sydist.com www.sydist.com/SiemensMurray
23
Plug-In Circuit Breakers
Combination Type Arc-Fault Circuit Interrupters
Type QP with INSTA-WIRETM 
Continuous
Current Rating @
40°C
1- Pole  
120/240V AC
Catalog Number
2 - Pole
120/240V AC
Common Trip
Catalog Number
2 - Pole
240V AC
Common Trip
Catalog Number
15
Q115 
Q215
Q215R 
15
10kA
20
Q120 
Q220
Q220R 
20
10kA
25
Q125
Q225
–
15
22kA
30
Q130
Q230
Q230R 
20
22kA
35
Q135 g
Q235
–
15
65kA
40
Q140
Q240
Q240R 
20
65kA
45
Q145 g
Q245
–
50
Q150
Q250
Q250R 
60
Q160
Q260
Q260R 
70
Q170
Q270
Q270R 
Ampere
Rating
Interrupting
Rating
80
–
Q280
–
15
10kA
90
–
Q290
–
20
10kA
100
–
Q2100
Q2100R 
15
22kA
110
–
Q2110
–
20
22kA
125
–
Q2125

Duplex Plug-In Circuit Breakers 
Breaker
Type
QT
1-Pole
10k AIC 120V AC
Ampere
Rating
Interrupting
Rating
Ul
Type
QAF2
QAFH2
HQAF2
Catalog
Number
QA115AFC
QA120AFC
QA115AFCH
QA120AFCH
QA115AFCHH
QA120AFCHH
2-Pole Plug-In Combination Type Arc-Fault Circuit Interrupters
Ul
Type
QAF
QAFH
Catalog
Number
Q215AFC
Q220AFC
Q215AFCH
Q220AFCH
Ground-Fault Circuit Interrupters 
Ampere Rating
2-Pole
Catalog
Number
15-15
Q1515
15-20
Q1520
20-20
Q2020
20-30
Q2030
15-30
Q3015
20-30
Q3020
30-30
Q3030
Breaker
Type
QPF
1-Pole 120V AC
Plug-in
g
 UL listed as SWD (switching duty) rated. Suitable for 120V AC
fluorescent lighting.
 HACR rated.
 For 22k AIC add “H” suffix.
 For 65k AIC add “HH” suffix.
 Contact factory for availability.
 White line neutral (pigtail) must be connected to the panel neutral for
the device to function.
g Built to order. Allow 2-3 weeks for delivery.
Built to order. Allow 2–3 weeks for delivery.
24
24 www.sydist.com
www.sydist.com/SiemensMurray
1-Pole Plug-In Combination Type Arc-Fault Circuit Interrupters
QPF
2-Pole 120/240V AC
Plug-in
Ampere
Rating
Catalog
Number
15
QF115 
20
QF120 
25
QF125 g
30
QF130
15
QF215
20
QF220
30
QF230
40
QF240
50
QF250
60
QF260
Plug-In Circuit Breakers cont.
Triplex Plug-In Circuit Breakers 
Breaker
Type
QT
2-Pole
10k AIC
120/240V AC
center common
trip
Ampere Rating
2-Pole
1-Pole
Catalog
Number
15
15
Q21515CT
15
20
Q21520CT
15
25
Q21525CT 
15
30
Q21530CT
15
35
Q21535CT 
15
40
Q21540CT
15
45
Q21545CT 
15
50
Q21550CT
20
20
Q22020CT
20
25
Q22025CT 
20
30
Q22030CT
20
35
Q22035CT 
20
40
Q22040CT
20
45
Q22045CT 
20
50
Q22050CT
30
30
Q23030CT
Quadplex Plug-In Circuit Breakers 
QT
2-Pole
10k AIC
120/240V AC
common trip
Breaker
Type
QN
2-Pole
120/240V AC
QNH
2-Pole
120/240V AC
HQN
2-Pole
120/240V AC
Ampere
Rating
Catalog
Number
150
QN2150
175
QN2175
Catalog
Number
QN2150R 

QN2175R  
200
QN2200
QN2200R 
150
QN2150H
QN2150RH 
175
QN2175H 
QN2175RH  
200
QN2200H
QN2200RH 
150
HQN2150
HQN2150R 
175
HQN2175 
HQN2175R  
200
HQN2200
HQN2200R 
Main Breaker Kits
Description
Catalog Number
Main breaker kit 100A 1PH QP 240V 22K
MBK100A
Main breaker kit 125A 1PH QP 240V 22K
MBK125A
Main breaker kit 150A 1PH QP 240V 22K
MBK150A
Main breaker kit 200A 1PH QP 240V 22K
MBK200A
Main breaker kit 225A 1PH QP 240V 22K
MBK225A
Main breaker kit 100A 3PH QP 240V 10K
MBK3100
Main breaker kit 150A 3PH QP 240V 10K
MBK3125
Main breaker kit 150A 3PH 240V 10K
MBK3150
Main breaker kit 175A 3PH 240V 10K
MBK3175
Main breaker kit 200A 3PH 240V 10K
MBK3200
Inside
2-Pole
Outside
2-Pole
Catalog
Number
Main breaker kit 225A 3PH 240V 10K
MBK3225
Main breaker kit 125A 3PH 240V 22K
MBK3125H
15
15
Q21515CT2
Main breaker kit 150A 3PH 240V 22K
MBK3150H
15
20
Q22020CT2
Main breaker kit 175A 3PH 240V 22K
MBK3175H
20
30
Q22030CT2
Main breaker kit 200A 3PH 240V 22K
MBK3200H
20
40
Q22040CT2
Main breaker kit 225A 3PH 240V 22K
MBK3225H
30
30
Q23030CT2
Main breaker kit 125A 3PH 240V 42K
MBK3125HH
30
40
Q23040CT2
Main breaker kit 150A 3PH 240V 42K
MBK3150HH
40
40
Q24040CT2
Main breaker kit 175A 3PH 240V 42K
MBK3175HH
50
30
Q25030CT2
Main breaker kit 200A 3PH 240V 42K
MBK3200HH
Main breaker kit 225A 3PH 240V 42K
MBK3225HH
Ampere Rating
Breaker
Type
Large Branch Circuit Breakers 
Ground Bar Kits (For Es And Pl Load Centers)
Hubs
Description
Catalog Number
Ground bar kit - 8 pos
EC1GB8
Description
Catalog Number
Ground bar kit - 8 pos, 2/0 lug
EC1GB82
HS type closure plate
ECHS000
Ground bar kit - 12 pos
EC2GB12
HS type hub - 3/4”
ECHS075
Ground bar kit - 12 pos, 2/0 lug
EC2GB122
HS type hub - 1”
ECHS100
Ground bar kit - 15 pos
EC2GB15
HS type hub - 1 1/4”
ECHS125
Ground bar kit - 15 pos, 2/0 lug
EC2GB152
HS type hub - 1 1/2”
ECHS150
Ground bar kit - 21 pos
EC3GB21
HS type hub - 2”
ECHS200
EC3GB212
HS type hub - 2 1/2”
ECHS250
Ground bar kit - 27 pos
EC3GB27
HA type closure plate
ECHA000
Ground bar kit - 27 pos, 2/0 lug
EC3GB272
HA type hub - 3/4”
ECHA075
Ground bar kit - 30 pos
EC3GB30
HA type hub - 1”
ECHA100
Ground bar kit - 30 pos, 2/0 lug
EC3GB302
HA type hub - 1 1/4”
ECHA125
EC3GB352
HA type hub - 1 1/2”
ECHA150
HV type closure plate
ECHV000
HV type hub - 2”
ECHV200
HV type hub - 2 1/2”
ECHV250
HV type hub - 3”
ECHV300
HV type hub - 3 1/2”
ECHV350
Ground bar kit - 21 pos, 2/0 lug
Ground bar kit - 35 pos, 2/0 lug
 HACR rated.
 For 22k AIC add “H” suffix.
 Reverse handle.
 Built to order. Allow 2-3 weeks
for delivery.
 For 65k AIC add “H” prefix.
HV type hub - 4”
ECHV400
www.sydist.com www.sydist.com/SiemensMurray
25
AC Disconnects
Ac Disconnects
Ac Disconnects With GFCI Receptacle
10,000A Ic Rated, Outdoor Type 3
Outdoor Type 3R
1 Phase
Description
120/240V AC
Catalog
Number
Pallet 
Quantity
60A Non-Fused
WN2060
360
60A Fused
WF2060
216
30A Fused
WF2030
360
60A Non-automatic switch
WNAS2060
360
Plastic AC Disconnects
10,000A IC rated
1 Phase
120/240V AC
Description
Catalog
Number
Pallet
Quantity
60A Non-Fused
WN2060PL
360
60A Fused
WF2060PL
216
30A Fused
WF2030PL
216
26
26 www.sydist.com
www.sydist.com/SiemensMurray

1 Phase
120/240V AC
Catalog
Number
Pallet 
Quantity
60A Non-Fused with 15A GFCI
receptacle
WN2060GFCI
144
60A Fused with 15A GFCI
receptacle 
WF2060GFCI
112
30A Fused with 15A GFCI
receptacle 
WF2030GFCI
112
Non-automatic switch with 15A
GFCI receptacle
WNAS2060GFCI
144
Description
 Fuses not included.
 To order in pallet quantities, place a “BP” at the end of the catalog number when
ordering. Example: WN2060  WN2060BP.
EQ Load Centers
EQ Load Centers
1 Phase. 3 Wire SN
120/240V AC
Breaker Used
Indoor Enclosure - Nema Type 1
Outdoor Enclosure - Nema Type 3R
Dimensions (Inches)
Frame Type
QP, QPH,
HQP
QN, QNH,
HQN
QPP, QPPH,
HQPP, QP
Dimensions (Inches)
Ampere
Rating
No. Of
Poles
Catalog
Number
Std.
Pkg.
H
W
D
Catalog
Number
Std.
Pkg.
H
W
D
60
2
E0204ML1060S
5
9 7/8
5 1/8
2 5/8
W0204ML1060
5
8
5
4 1/4
60
2
E0204ML1060F
5
9 7/8
5 1/8
2 5/8
-
-
-
-
-
100
2
E0202MB1100
1
17 1/8
7 3/8
4 5/16
W0202MB1100CU
1
17.4
7.3
4.3
125
2
E0204ML1125SCU
1
17 1/8
7 1/8
4 1/4
W0204ML1125CU
1
17 1/8
7 3/8
4 5/16
150
2
-
-
-
-
-
W0202MB1150CU
1
19 3/4
8.4
4.6
200
2
-
-
-
-
-
W0202ML1200CU
1
19 3/4
8.4
4.6
200
2
E0202MB1200
-
19 3/8
8 1/2
4
W0202MB1200CU
1
19 3/4
8.4
4.6
225
1-4
-
-
-
-
-
W0406ML1225CU
1
23
10
4 1/8
 Will not accommodate 2-pole GFCI or circuit breaker with shunt trip.
 42,000A IR maximun. Copper wire only at 225A.
 Main breaker factory installed.
 CSA Listed.
www.sydist.com www.sydist.com/SiemensMurray
27
Schaedler Yesco Distribution, Inc.
3982 Paxton St.
Harrisburg, PA 17111
www.sydist.com
Siemens Industry, Inc.
5400 Triangle Parkway
Norcross, GA 30092
1-800-241-4453
info.us@siemens.com
Subject to change without prior notice
Order No. PDSA-SCHYS-0115
Printed in USA
All rights reserved
© 2015 Siemens Industry, Inc.
www.usa.siemens.com/powerdistribution
The information provided in this brochure contains merely
general descriptions or characteristics of per formance which
in actual case of use do not always apply as described or
which may change as a result of further development of the
products. An obligation to provide the respective
characteristics shall only exist if expressly agreed in the
terms of contract.
All product designations may be trademarks or product
names of Siemens AG or supplier companies whose use by
third parties for their own purposes could violate the rights
of the owners.