Electrical distribution products Contractor quick selector guide Our History • • • • • Over 90 years of servicing electrical needs for all markets. It began in 1924 when Schaedler Brothers was created by Harry, Andrew, and William Schaedler, a sibling partnership that started simply with the purchasing, plating, assembling, and selling of light fixture parts. Twenty years later, Motter Electric Company was incorporated to distribute electrical supplies. In 1956, Motter officially changed its name to York Electrical Supply Company (YESCO). In 1999, Schaedler Brothers, Inc., and YESCO merged, creating what to this day is the largest electrical distributor headquartered in Central Pennsylvania. As part of our heritage, we have developed the same capabilities of a large chain, but continue to operate as your neighborhood supplier with a personal touch. We invite you to try all of our services from basic to specialty. Schaedler Yesco Distribution, Inc. is a leading electrical distributor of top-quality products from preferred manufacturers of electrical, automation, lighting, data communication, energy, and oil and gas supplies. We pride ourselves on offering a variety of products from brands you trust that fit your current need and budget. We make every effort to monitor and adjust our product selection and inventory requirements so you have access to what you need, when you need it. Our convenient locations, will-call counter pick-ups, and vast delivery vehicle fleet ensure the fast turnaround you would expect from a preferred business partner. Our Mission To enhance our customers’ performance and profitability by being the leading provider of distributor services and solutions. Markets We Serve Services We Provide Industrial Delivery OEM (Original Equipment Manufacturer) Emergency Services Construction Recycling Services Commercial Return Policy Government Inventory Management Solutions (IMS) Oil & Gas Technical & Product Specialists www.sydist.com • 1-800-998-1621 Web Order Entry Training Safety Switches General Duty General Duty Safety Switches 240V Fusible 2P, 2F, and Neutral Accessories (General and Heavy Duty) 240V AC / 250V DC Ampere Rating Indoor Type 1 Catalog Number Outdoor Type 3R Catalog Number 30 GF221N GF221NR 60 GF222N GF222NR 100 GF223N GF223NR 200 GF224N GF224NR 400 GF225NH GF225NRH 400 GF225N GF225NR 600 GF226NH GF226NRH 600 GF226N GF226NR 3P, 3F, and Neutral 240V AC / 250V DC Ampere Rating Indoor Type 1 Catalog Number Outdoor Type 3R Catalog Number 30 GF321N GF321NR 60 GF322N GF322NR 100 GF323N GF323NR 200 GF324N GF324NR 400 GF325NH GF325NRH 400 GF325N GF325NR 600 GF326NH GF326NRH 600 GF326N GF326NR 240V Non-Fusible 2P or 3P 240V AC / 250V DC Class R Fuse Clip Kits Catalog Number Description GSRK321 Class R Fuse Clip Kit (30A General Duty Only) HR21 Class R Fuse Clip Kit (30A, 240V Heavy Duty Only) HR612 Class R Fuse Clip Kit (30A, 600V / 60A, 240V) HR62 Class R Fuse Clip Kit (60A, 600V) HR63 Class R Fuse Clip Kit (100A) HR64 Class R Fuse Clip Kit (200A) HR656 Class R Fuse Clip Kit (400A / 600A) Neutral Kits Description Kit Catalog Number 30 GD W410190 30 HD. 60 GD HN612 g 60, 100 HD, 100 GD HN623 g 200 HN64 400 & 600 HN656 800 & 1200 HN678 Equipment Ground Kits Switch Ampere Rating Catalog Number Number Of Terminals Wire Range Per Terminal (Cu/Ai) 30A GD GSGK60 2 #14-8 AWG 60-200GD HG61234 2 #14-4 AWG 30-200 HD HG61234 2 #14-4 AWG 400 & 600 HG656 4 #14-2/0 AWG 800-1200 HG678 8 #6 AWG-250 Kcmil Ampere Rating Indoor Type 1 Catalog Number Outdoor Type 3R Catalog Number 30 GNF321 GNF321R 60 GNF322 GNF322R 100 GNF323 GNF323R 200 GNF324 GNF324R 400 GNF325 HNF365R Use 600V Switch With 1 NO & 1 NC Isolated Contacats 30-200 HA161234 GNF326 HNF366R Use 600V Switch 400-1200 HA165678 600 These switches are UL listed for application on grounded B-phase systems. Suitable for use on 3-phase motor loads. Service entrance rated. Height reduced switches (45.25" rather than 56" in height) for use with 500MCM or smaller conductors. Also for 60A, 240V General Duty and Heavy Duty. Provides 1 normally open and 1 normally closed contact. g GD = General Duty, HD = Heavy Duty 4 4 www.sydist.com www.sydist.com/SiemensMurray Auxiliary Contacts Switch Ampere Aux. Switch Catalog Number Kit Ampere Rating 125V ACMax. Horsepower Rating 250V AC Max. 28V Dc Max. 125V AC Max. 250V AC Max. 10 10 7 1/2 3/4 10 10 – 1/2 3/4 Safety Switches Heavy Duty Heavy Duty Safety Switches 600V Non-Fusible 600V Fusible 480V AC / 600V AC / 600V DC 2P, 2F 480V AC / 600V AC / 600V DC 2P Outdoor Type 3R Catalog Number Ampere Rating Indoor Type 1 Catalog Number Outdoor Type 3R Catalog Number HF261 HF261R 30 HNF261 HNF261R HF262 HF262R 60 HNF262 HNF262R Ampere Rating Indoor Type 1 Catalog Number 30 60 100 HF263 HF263R 100 HNF263 HNF263R 400 HF265 HF265R 400 HNF265 HNF265R 600 HF266 HF266R 600 HNF266 HNF266R 3P, 3F 480V AC / 600V AC / 250V DC Heavy Duty Safety Switches 600V Non-Fusible Ampere Rating Indoor Type 1 Catalog Number Outdoor Type 3R Catalog Number 30 HF361 HF361R 60 HF362 HF362R Ampere Rating Indoor Type 1 Catalog Number 480V AC / 600V AC / 250V DC 3P Outdoor Type 3R Catalog Number 100 HF363 HF363R 30 HNF361 HNF361R 200 HF364 HF364R 60 HNF362H HNF362RH 400 HF365H HF365RH 60 HNF362 HNF362R 400 HF365 HF365R 100 HNF363 HNF363R 600 HF366H 200 HNF364 HNF364R HF366RH 600 HF366 HF366R 400 HNF365 HNF365R 800 HF367 HF367R 600 HNF366 HNF366R 1200 HF368 HF368R 800 HNF367 HNF367R 1200 HNF368 HNF368R Conduit Size (Inches) Catalog Number Used On Cover ECHA000 3/4 ECHA075 1 ECHA100 1 1/4 ECHA125 Cover ECHS000 3/4 ECHS075 1 ECHS100 1 1/4 ECHS125 1 1/2 ECHS150 2 ECHS200 2 1/2 ECHS250 2 1/2 ECHV250 3 ECHV300 3 1/2 ECHV350 4 ECHV400 3P, 3F, and Neutral 480V AC / 600V AC / 250V DC Ampere Rating Indoor Type 1 Catalog Number Outdoor Type 3R Catalog Number 30 HF361N HF361NR 60 HF362N HF362NR 100 HF363N HF363NR 200 HF364N HF364NR 400 HF365N HF365NR 600 HF366N HF366NR 800 HF367N HF367NR 1200 HF368N HF368NR Built to order. Allow 3 - 5 weeks for delivery. Suitable for use as service entrance equipment except for 1200 when used on a 480 or 600V grounded wye system. Use 3-Pole switch for 200A application. Compact switch (11.1”H, 6.6”W box less cover and handle). Short circuit withstand rating—100,000 RMS sym. amps. 60-200A 3-Pole switches are also rated 600V DC. Height reduced switch (45.25 rather than 56 inches in height) for use with 500MCM or smaller conductors. Hubs suitable for 3R switches. Hubs Type 3R 30A GD Only 60–200A GD 30–200A HD 400–1200A www.sydist.com www.sydist.com/SiemensMurray 5 New Revised P1 Unassembled Panelboards To better serve the needs of customers, Authorized Siemens Unassembled Panelboard Distributors offer product flexibility, quicker job turn-around, and affordable pricing. All Siemens unassembled panelboards are fully backed for high quality, trouble-free operation and are labeled as Suitable for use as Service Entrance Equipment. Flexibility and ease of assembly: Customer oriented design creates installation convenience. For all of its one-of-a-kind features, the P1 panelboard is also designed to be extremely userfriendly. For instance, field convertible main breaker and main lug kits, (through 400 amps), will allow you to switch from main lug to main breaker, and vice versa with no change in box size or additional cabling. Plus, lay-in construction (for 250 A CU) and/or removable lugs make wiring the main and neutral lugs easier and faster. To further speed wiring, as well as reduce clutter, the P1 panel also features a split neutral design and branch neutral connections which are closer to the breakers than competitors. Additionally, field addable sub-fed breakers (up to 250 amps) or feed through lug kits can be field installed without utilizing any of your feeder breaker positions or increasing your box height. Furthermore, the unique design allows the panel to be inverted in the field and keep its labeling legible. 1) Completely symmetrical boxes may be mounted with either end up. There are two pre-punched equipment ground connector locations for contractor friendly installation. be performed easily. MLO kits and Main Breaker Kits are interchangeable and can be changed/added in the field without making changes to the enclosure or interior. 2) Box comes pre-punched for optional, field installable doorin-door or hinged style trims. There are also two pre-punched ground connector locations. The panel box will accept both standard ground connector (EGK and ECGK) assemblies and insulated ground connector kits (IGK and ICGK). 5) Branch neutral connections are near the breaker connections to speed wiring and reduce clutter. The standard P1 neutral is rated for 100% of the panel’s ampacity and will accept copper or aluminum wire. Optional 200% and 2/0 neutrals are also available. 3) Interior is completely symmetrical allowing it to be changed from top to bottom feed by simply rotating the interior. 6) The panel includes space to add (1) sub-feed breaker (max 250 amps), feed-thru lugs or TPS3 (SPD) kit. 4) Choose either a Main Breaker kit or Main Lug kit with which to terminate your incoming cables. Main lug kits are contractor friendly lugs through 350 kcmil (250 amp panel) or (1) 600 kcmil or (2) 250 kcmil connectors for 400 amp panels. No line connectors in the P1 panel require multiple wires under one screw. Main Breaker kits (250 amps and below) are horizontally mounted allowing field convertible top or bottom feeds to 7) Siemens standard trim has hidden hinges and mounting hardware for added safety. The rounded door corners not only enhance the panel’s appearance but also help to eliminate injuries caused from sharp corners. 3 8) Semi-flush lock comes standard. Easily identified locked position denoted by keyway being horizontal when door has been locked. 4 2 5 7 1 6 6 6 www.sydist.com www.sydist.com/SiemensMurray 8 Catalog Numbering System Unassembled Panelboards Type P1 unassembled panelboards are completely convertible from main lug to main breaker and vice-versa. Additionally feed-thru lugs, or subfeed circuit breakers up to 400 ampere can be added without increasing the box height for Revised P1 with “T” suffix, see the chart. Note: Main/Subfeed Breaker mounting kits may be ordered with or without breakers included, see page 5 and 6 for selection. 4. List required branch circuit breakers and filler plates to cover any unused positions. 5. Select any modifications or accessories. 1. Compute total number of poles to determine interior catalog number. (Note: BL / BQD (or) xGB Main Breaker will use unit space. The total number of poles should include 2 (or) 3 poles for 1-phase (or) 3-phase mains.) 2. List catalog number and price of interior, box and front. 3. Select main lug kit or main breaker kit from appropriate tables. Note: Revised P1 was introduced in June 2014. All original P1 devices do not include the "Subfeed Space" Indicator. All original P1 included the Subfeed Space as standard. P 1 X 1 8 MC 2 5 0 A T Type of Panel P1 Voltage and System X = 208Y/120, 3-Phase 4-Wire A = 120/240V, 1-Phase 3-Wire E = 480Y/277V, 3-Phase 4-Wire 7 = xGB interior, 480Y/277V, 3-Phase 4-Wire Circuits 18, 30, 42, 54* (*Revised P1 only) Mains MC = Convertible mains Select Main Lug Kit or Breaker Mounting Kit from page ? Amperage 400A max (typically 250A or 400A) Main Bus Material A = Aluminum C = Copper Subfeed Space Indicator (for Revised P1 only) T = Subfeed Space Included Note: Standard bussing in P1 panels is tin plated for aluminum and copper. Standard bus is temperature rated to the maximum amperage in the panel. Branch Breakers Panel Type P1, Revised P11 Voltage (Max.) 240 480 / 277 600 / 347 3 Breaker Type BL, BLH, HBL, BQD, NGB, HGB, LGB BQD, NGB, HGB, LGB, BQDG 2, NGB, HGB, LGB Additional Information See Page 17 1 ConsultsalesofficeforavailabilityofCSA. 2 See Speedfax for additional information. 3 600/347V options are not available in a UPB panel - see factory assembled section. www.sydist.com www.sydist.com/SiemensMurray 7 Distributor Stock Type P1 Panelboards Pricing An Unassembled Panel 400A Max. — 20" Wide x 5.75" Deep 1. Choose the appropriate Interior from the table below. 2. Choose the Main Device: Main Lugs from page 16, Main Breaker Kit from pages 16 - 17 and Main Breakers from Section 7. 3. Choose Branch Breakers. BL, BQD and xGB breakers from Section 7. 4. Choose Feed-Thru Lugs or Subfeed Breaker Kit from pages 16 - 17 and Subfeed Breaker from Section 7. Type P1 Unassembled Panelboards (Revised P1 introduced 2014) Amps Max. # of Poles Original Interior Catalog Number Box Size Type 1 Encl. Type 3R/12 Encl. Type 1 Front Surface Type1 Front Flush P1A18MC250AT P1A30MC250AT P1A42MC250AT P1A54MC250AT — P1A30MC400AT P1A42MC400AT P1A54MC400AT P1A18MC250CT P1A30MC250CT P1A42MC250CT P1A54MC250CT — P1A30MC400CT P1A42MC400CT P1A54MC400CT 32 38 44 50 — 62 68 74 32 38 44 50 — 62 68 74 B32 B38 B44 B50 — B62 B68 B74 B32 B38 B44 B50 — B62 B68 B74 WP32 WP38 WP44 WP50 — WP62 WP68 WP74 WP32 WP38 WP44 WP50 — WP62 WP68 WP74 S32B S38B S44B S50B — S62B S68B S74B S32B S38B S44B S50B — S62B S68B S74B F32B F38B F44B F50B — F62B F68B F74B F32B F38B F44B F50B — F62B F68B F74B P1X18MC250AT P1X30MC250AT P1X42MC250AT P1X54MC250AT — P1X30MC400AT P1X42MC400AT P1X54MC400AT P1X18MC250CT P1X30MC250CT P1X42MC250CT P1X54MC250CT — P1X30MC400CT P1X42MC400CT P1X54MC400CT 32 38 44 50 — 62 68 74 32 38 44 50 — 62 68 74 B32 B38 B44 B50 — B62 B68 B74 B32 B38 B44 B50 — B62 B68 B74 WP32 WP38 WP44 WP50 — WP62 WP68 WP74 WP32 WP38 WP44 WP50 — WP62 WP68 WP74 S32B S38B S44B S50B — S62B S68B S74B S32B S38B S44B S50B — S62B S68B S74B F32B F38B F44B F50B — F62B F68B F74B F32B F38B F44B F50B — F62B F68B F74B P1E18MC250AT P1E30MC250AT P1E42MC250AT P1E54MC250AT — P1E30MC400AT P1E42MC400AT P1E54MC400AT P1E18MC250CT P1E30MC250CT P1E42MC250CT P1E54MC250CT — P1E30MC400CT P1E42MC400CT P1E54MC400CT 32 38 44 50 — 62 68 74 32 38 44 50 — 62 68 74 B32 B38 B44 B50 — B62 B68 B74 B32 B38 B44 B50 — B62 B68 B74 WP32 WP38 WP44 WP50 — WP62 WP68 WP74 WP32 WP38 WP44 WP50 — WP62 WP68 WP74 S32B S38B S44B S50B — S62B S68B S74B S32B S38B S44B S50B — S62B S68B S74B F32B F38B F44B F50B — F62B F68B F74B F32B F38B F44B F50B — F62B F68B F74B P1718MC250AT P1730MC250AT P1742MC250AT P1754MC250AT — P1730MC400AT P1742MC400AT P1754MC400AT P1718MC250CT P1730MC250CT P1742MC250CT P1754MC250CT — P1730MC400CT P1742MC400CT P1754MC400CT 32 38 44 50 — 62 68 74 32 38 44 50 — 62 68 74 B32 B38 B44 B50 — B62 B68 B74 B32 B38 B44 B50 — B62 B68 B74 WP32 WP38 WP44 WP50 — WP62 WP68 WP74 WP32 WP38 WP44 WP50 — WP62 WP68 WP74 S32B S38B S44B S50B — S62B S68B S74B S32B S38B S44B S50B — S62B S68B S74B F32B F38B F44B F50B — F62B F68B F74B F32B F38B F44B F50B — F62B F68B F74B Revised P1 Interior Catalog Number Convertible Mains — 1-Phase, 3-Wire 120/240V 250 400 250 400 18 30 42 54 18 30 42 54 18 30 42 54 18 30 42 54 P1A18MC250A P1A30MC250A P1A42MC250A P1A18MC400A P1A30MC400A P1A42MC400A P1A18MC250C P1A30MC250C P1A42MC250C P1A18MC400C P1A30MC400C P1A42MC400C Convertible Mains — 3-Phase, 4-Wire 208Y/120V 250 400 250 400 18 30 42 54 18 30 42 54 18 30 42 54 18 30 42 54 P1X18MC250A P1X30MC250A P1X42MC250A P1X18MC400A P1X30MC400A P1X42MC400A P1X18MC250C P1X30MC250C P1X42MC250C P1X18MC400C P1X30MC400C P1X42MC400C Convertible Mains — 3-Phase, 4-Wire 480Y/277V 250 400 250 400 18 30 42 54 18 30 42 54 18 30 42 54 18 30 42 54 P1E18MC250A P1E30MC250A P1E42MC250A P1E18MC400A P1E30MC400A P1E42MC400A P1E18MC250C P1E30MC250C P1E42MC250C P1E18MC400C P1E30MC400C P1E42MC400C Interiors for xGB Breakers — 3-Phase, 4-Wire 480Y/277V 250 400 250 400 18 30 42 54 18 30 42 54 18 30 42 54 18 30 42 54 P1718MC250A P1730MC250A P1742MC250A P1718MC400A P1730MC400A P1742MC400A P1718MC250C P1730MC250C P1742MC250C P1718MC400C P1730MC400C P1742MC400C 42 circuit with Back-fed Main 54 circuit 400A Front included in NEMA 3R and 3R/12 Box. 8 8 www.sydist.com www.sydist.com/SiemensMurray Product Category UPB Distributor Stock Type P1 Panelboards Lug Kits — Main or Feed Thru Amp Wire Range Rating Matl. (includes Neutral) AL 250 CU AL 400 CU 400 AL Service 1 Phase 3 Phase 1 Phase (1) #6 AWG350 kcmil (CU or AL) 3 Phase 1 Phase (2) 1/0 - 250 kcmil or (1) #2 AWG-600 kcmil 3 Phase 1 Phase (2) 1/0 - 4/0 or (1) 1/0 - 600 kcmil 3 Phase 1 Phase AL 1/0-750 kcmil (max. 600 kcmil CU wire) 3 Phase (1) #6 AWG350 kcmil (CU or AL) Original Catalog Number MLKA1 MLKA3 MLKC1 MLKC3 4MLKA1 4MLKA3 4MLKC1 4MLKC3 – – Revised P1 Catalog Number MLKA1A MLKA3A MLKC1A MLKC3A 4MLKA1A 4MLKA3A 4MLKC1A 4MLKC3A 4MLKA1B 4MLKA3B MBKFD3A Breaker Mounting Kits — Main or Subfeed Strap Kit w/o Breaker Ampere Rating 100A Breaker Types BQD 100A BL, BLH, HBL 125A NGB, HGB, LGB 125A ED4, ED6, HED4, HED6 225A QJ2, QJH2, QJ2-H 250A FXD6, FD6, HFD6, HFXD6 400A JXD2, JD6, JXD6, HJD6, HJXD6 400 Service 3-Phase 1-Phase 3-Phase 1-Phase 3-Phase 1-Phase 3-Phase 1-Phase 3-Phase 1-Phase 3-Phase 1-Phase 3-Phase Original P1 Catalog Number MBKBC3 MBKBL1 MBKBL3 MBKNB1 MBKNB3 MBKED1 MBKED3 MBKQJ1 MBKQJ3 MBKFD1 MBKFD3 MBKJD1 MBKJD3 amp kit is for main only — not allowed for subfeed breaker. Back-fed main occupies branch space. Copper Neutral Lug Kits — 250A Number of Circuits Description 18 30 42 54, 66 2 or 4 Branch Neutral Strips, 1 Main Neutral Lug, Hardware 2/0 Neutral Lug Kits — 250A and 400A 18 30 42 54, 66 2 or 4 Branch Neutral Strips, 1 Main Neutral Lug, Hardware 200% Neutral Lug Kits/250A 18 30 42 54, 66 2 or 4 Branch Neutral Strips, 1 Main Neutral Lug, Hardware 200% Neutral Lug Kits/400A 18 30 42 54, 66 2 or 4 Branch Neutral Strips, 1 Main 600MCM Neutral Lug, Hardware Replacement Parts Only Revised P1 Catalog Number Use Back-fed Main Label Kit # MBKBFA (includes Neutral Lug, "MAIN" label and instructions) MBKQJ3A MBKED1A MBKED3A MBKQJ1A MBKQJ3A MBKFD1A MBKFD3A MBKJD1A MBKJD3A Miscellaneous Parts and Accessories Original P1 Catalog Number Revised P1 Catalog Number CNKL18 CNKL30 CNKL42 — Use 30 ckt kit CNLK30A CNLK42A CNLK54A — — — — Use 30 ckt kit LNLK30A LNLK42A LNLK54A Catalog # BK1 BK1A BK2 BK3 IMK1 11-1824-01 12-1110-01 11-1056-01 NBK03 NBK04 NBK05 2NLK18 2NLK30 2NLK42 — Use 30 ckt kit 2NLK30A 2NLK42A 2NLK54A 42NLK18 42NLK30 42NLK42 — Use 30 ckt kit 42NLK30A 42NLK42A 42NLK54A NBK06 EGK ECGK IGK ICGK EWK1 EWK2 EBF1 P1SCRWS DFFP1 P1CONBPHCU P1CONBPHAL P1CONACPHCU P1CONACPHAL Product Category UPB Description Bonding Kit for 250A max. Original P1 Panels Bonding Kit for 250A max. Revised P1 Panels Bonding kit for S1/S2 400 & 600 Bonding kit Interior Adjusting Kit Directory Card Holder Directory Card NEMA Instruction Book Number Strips 1–42 . Stick-on type; Use w/ P1 series Panels Number Strips 43–84. Stick-on type; Use w/ P1 series Panels Number Strips 85–126. Stick-on type; Use w/ P1 series Panels Number Strips 127–168. Stick-on type; Use w/ P1 series Panels AL Ground Bus 44 Connections CU Ground Bus 44 Connections Insulated AL Ground Bus Insulated CU Ground Bus End Wall Kit with Knockouts (20" W x 5.75" DP) End Wall Kit with Knockouts (24" W x 7.75" DP) NEB/HEB Filler Plate Package of 42 breaker mounting screws for P1 1" Branch circuit filler plate (suitable for replacing QF3 in P1 thru P5 Panelboards and Switchboards) Connector kit – 6 pcs. B-phase Copper Connector kit – 6 pcs. B-phase Aluminum Connector kit – 6 pcs. A or C-phase Copper Connector kit – 6 pcs. A or C-phase Aluminum www.sydist.com www.sydist.com/SiemensMurray 9 Warehouse Stock/Unassembled Main Breaker Mounting Kits with Breakers for P1 Panels (250A and lower can be used as subfeed kits also) Original P1 Catalog Number MBKED3100 MBKED3125 MBKQJ1125 MBKQJ1150 MBKQJ1175 MBKQJ1200 MBKQJ1225 MBKQJ3125 MBKQJ3150 MBKQJ3175 MBKQJ3200 MBKQJ3225 MBKQJ1125H MBKQJ1150H MBKQJ1175H MBKQJ1200H MBKQJ1225H MBKQJ3125H MBKQJ3150H MBKQJ3175H MBKQJ3200H MBKQJ3225H MBKFD3150 MBKFD3175 MBKFD3200 MBKFD3225 MBKFD3250 MBKJD1300 MBKJD3300 MBKJD1400 MBKJD3400 MBKJD12300 MBKJD32300 MBKJD12400 MBKJD32400 Revised P1 Catalog Number Ratings Description MBKED3100A MBKED3125A MBKQJ1125A MBKQJ1150A MBKQJ1175A MBKQJ1200A MBKQJ1225A MBKQJ3125A MBKQJ3150A MBKQJ3175A MBKQJ3200A MBKQJ3225A MBKQJ1125HA MBKQJ1150HA MBKQJ1175HA MBKQJ1200HA MBKQJ1225HA MBKQJ3125HA MBKQJ3150HA MBKQJ3175HA MBKQJ3200HA MBKQJ3225HA MBKFD3150A MBKFD3175A MBKFD3200A MBKFD3225A MBKFD3250A MBKJD1300A MBKJD3300A MBKJD1400A MBKJD3400A MBKJD12300A MBKJD32300A MBKJD12400A MBKJD32400A 240V Kit w/3-pole ED4 100A breaker Kit w/3-pole ED4 125A breaker Kit w/2-pole QJ2 125A breaker Kit w/2-pole QJ2 150A breaker Kit w/2-pole QJ2 175A breaker Kit w/2-pole QJ2 200A breaker Kit w/2-pole QJ2 225A breaker Kit w/3-pole QJ2 125A breaker Kit w/3-pole QJ2 150A breaker Kit w/3-pole QJ2 175A breaker Kit w/3-pole QJ2 200A breaker Kit w/3-pole QJ2 225A breaker Kit w/2-pole QJ2H 125A breaker Kit w/2-pole QJ2H 150A breaker Kit w/2-pole QJ2H 175A breaker Kit w/2-pole QJ2H 200A breaker Kit w/2-pole QJ2H 225A breaker Kit w/3-pole QJ2H 125A breaker Kit w/3-pole QJ2H 150A breaker Kit w/3-pole QJ2H 175A breaker Kit w/3-pole QJ2H 200A breaker Kit w/3-pole QJ2H 225A breaker Kit w/3-pole FXD6 150A breaker Kit w/3-pole FXD6 175A breaker Kit w/3-pole FXD6 200A breaker Kit w/3-pole FXD6 225A breaker Kit w/3-pole FXD6 250A breaker Kit w/2-pole JXD6 300A breaker Kit w/3-pole JXD6 300A breaker Kit w/2-pole JXD6 400A breaker Kit w/3-pole JXD6 400A breaker Kit w/2-pole JXD2 300A breaker Kit w/3-pole JXD2 300A breaker Kit w/2-pole JXD2 400A breaker Kit w/3-pole JXD2 400A breaker 65KA 65KA 10KA 10KA 10KA 10KA 10KA 10KA 10KA 10KA 10KA 10KA 42KA 42KA 42KA 42KA 42KA 42KA 42KA 42KA 42KA 42KA 65KA 65KA 65KA 65KA 65KA 65KA 65KA 65KA 65KA 65KA 65KA 65KA 65KA 480V 18KA 18KA — — — — — — — — — — — — — — — — — — — — 35KA 35KA 35KA 35KA 35KA 35KA 35KA 35KA 35KA – – – – Branch Breakers Selection for P1 Selection Guide 1. Select breaker type. 2. Select required amperage. 3. Select number of poles. 4. Select branch breaker catalog numbers. 5. Select ground bar and filler plates. (See replacement parts & accessories on Page 15.) 300A Main installed. These Revised P1 kits can now be used as top or bottom feed. Kits are for Main only. New “Revised P1” kits can be used for either top feed or bottom feed. NOTE: "Revised P1" Kits above only work for interior numbers ending in "T" or "N". Use "Original P1" kits for all others. AFCI – Combination Type Arc Fault Circuit Interrupter Interrupting Ratings (kA) RMS Symmetrical Amperes BAF 2-pole Ampere Rating 15 20 15 20 15 20 15 20 Catalog Number B115AFC B120AFC B115AFCH B120AFCH BA115AFCHH BA120AFCHH B215AFC B220AFC Volts AC 120 10 10 22 22 65 65 10 10 BAFH 2-pole 15 20 B215AFCH B220AFCH 22 22 Breaker Type BAF2 1-pole BAFH2 1-pole HBAF2 1-pole Switching Neutrals Breaker Type BG 2-Wire Common Trip BG 3-Wire Common Trip * Built to order. Ampere Rating 15 20 30 15 20 30 Catalog Number BG215* BG220* BG230* BG315* BG320* BG330* . Product Category UPB 10 www.sydist.com 10 www.sydist.com/SiemensMurray 120/240 — — — — — — — 240 — — — — — — — — — — — — — Maximum Interrupting Rating (kA) 120V AC 120/240V AC 240V AC 10 — — 10 — — 10 — — — 10 — — 10 — — 10 — AFCI – Branch Feeder Type Arc Fault Circuit Interrupter Interrupting Ratings (kA) RMS Symmetrical Amperes Breaker Type BAF2 1-pole BAF2H 1-pole HBAF2 1-pole Ampere Rating 15 20 15 20 15 20 Catalog Number BA115AF BA120AF BA115AFH BA120AFH BA115AFHH BA120AFHH Volts AC 120 10 10 22 22 65 65 120/240 — — — — — — 240 — — — — — — Dual Function AFCI/GFCI Circuit Breaker Interrupting Ratings (kA) RMS Symmetrical Amperes Breaker Type BFGA2 1-pole BFGAH2 1-pole HBFGA2 1-pole Ampere Rating 15 20 15 20 15 20 Catalog Number BA115DF BA120DF BA115DFH BA120DFH BA115DFHH BA120DFHH Volts AC 120 10 10 22 22 65 65 120/240 — — — — — — 240 — — — — — — Warehouse Stock / Unassembled Type P1 Panelboards Branch Breakers Selection for P1 Selection Guide 1. Select breaker type. 2. Select required amperage. 3. Select number of poles. 4. Select branch breaker catalog numbers. BL Branch Breakers – 10,000A IR Amp Rating 15 20 25 30 35 40 45 50 55 60 70 80 90 100 1-Pole 120/240V B115 B120 B125 B130 B135 B140 B145 B150 B155 B160 B170 — — — 2-Pole 120/240V B215 B220 B225 B230 B235 B240 B245 B250 — B260 B270 B280 B290 B2100 2-Pole 240V B215R B220R B225R B230R B235R B240R B245R B250R — — — — — — HBL Branch Breakers – 65,000A IR Amp Rating 15 20 30 40 50 60 70 80 90 100 1-Pole 120/240V B115HH B120HH B130HH B140HH B150HH — — — — — 2-Pole 120/240V B215HH B220HH B230HH B240HH B250HH B260HH B270HH B280HH B290HH B2100HH 3-Pole 240V B315 B320 B325 B330 B335 B340 B345 B350 — B360 B370 B380 B390 B3100 3-Pole 240V B315HH B320HH B330HH B340HH B350HH B360HH B370HH B380HH B390HH B3100HH GFCI Personnel Protection (5MA) Interrupting Ratings (kA) RMS Symmetrical Amperes Breaker Type BLF 1-Pole BLF 2-Pole BLHF 1-Pole BLHF 2-Pole Ampere Rating 15 20 25 30 15 20 30 40 50 60 15 20 30 15 20 30 40 50 60 Catalog Number BF115 BF120 BF125 BF130 BF215 BF220 BF230 BF240 BF250 BF260 BF115H BF120H BF130H BF215H BF220H BF230H BF240H BF250H BF260H Volts AC 120 10 10 10 10 — — — — — — 22 22 22 — — — — — — 120/240 — — — — 10 10 10 10 10 10 — — — 22 22 22 22 22 22 240 — — — — — — — — — — — — — — — — — — — 5. Select ground bar and filler plates. (See replacement parts & accessories on Pages 17 and 18.) BLH Branch Breakers – 22,000A IR Amp Rating 15 20 25 30 40 50 55 60 70 80 90 100 1-Pole 120/240V B115H B120H B125H B130H B140H B150H B155H B160H B170H — — — 2-Pole 120/240V B215H B220H B225H B230H B240H B250H — B260H B270H B280H B290H B2100H 3-Pole 240V B315H B320H B325H B330H B340H B350H — B360H B370H B380H B390H B3100H BQD Branch Breakers – 14,000A IR Max. @ 480/277 Vac / 65,000A IR max. @ 240 Vac Amp Rating 15 20 25 30 35 40 45 50 60 70 80 90 100 1-Pole 277V BQD115 BQD120 BQD125 BQD130 BQD135 BQD140 BQD145 BQD150 BQD160 BQD170 BQD180 BQD190 BQD1100 2-Pole 480Y/277V BQD215 BQD220 BQD225 BQD230 BQD235 BQD240 BQD245 BQD250 BQD260 BQD270 BQD280 BQD290 BQD2100 3-Pole 480Y/277V BQD315 BQD320 BQD325 BQD330 BQD335 BQD340 BQD345 BQD350 BQD360 BQD370 BQD380 BQD390 BQD3100 GB Family Branch Breakers NGB – 25,000 A IR Max. @ 480/277V AC / 100,000 A IR @ 240V AC HGB – 35,000 A IR Max. @ 480/277V AC / 100,000 A IR @ 240V AC LGB – 65,000 A IR Max. @ 480/277V AC / 100,000 A IR @ 240V AC Amp Rating 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 1-pole 277V xGB1B015B xGB1B020B xGB1B025B xGB1B030B xGB1B035B xGB1B040B xGB1B045B xGB1B050B xGB1B060B xGB1B070B xGB1B080B xGB1B090B xGB1B100B xGB1B110B xGB1B125B 2-pole 480Y/277V xGB2B015B xGB2B020B xGB2B025B xGB2B030B xGB2B035B xGB2B040B xGB2B045B xGB2B050B xGB2B060B xGB2B070B xGB2B080B xGB2B090B xGB2B100B xGB2B110B xGB2B125B 3-pole 480Y/277V xGB3B015B xGB3B020B xGB3B025B xGB3B030B xGB3B035B xGB3B040B xGB3B045B xGB3B050B xGB3B060B xGB3B070B xGB3B080B xGB3B090B xGB3B100B xGB3B110B xGB3B125B Replace x with N, H or L depending on desired type of breaker NOTE: 2-pole and 3-pole xGB Frame Breakers are also rated at 14,000 A IR max. for 600Y/347V AC systems. UPB interiors are only rated to 480V max. - see factory assembled section for proper interiors. n Built to order. Allow 2–3 weeks for delivery. HACR rated. To add shunt trip to BL breakers, see Speedfax for Breaker Accessories. To add shunt trip to BQD breakers, see Speedfax for Breaker Accessories. www.sydist.com www.sydist.com/SiemensMurray 11 Siemens Single-Phase Load Centers Features and Comparison www.usa.siemens.com/loadcenters Features ES Series Murray PL Series Bussing AL AL CU Convertible MB to MLO Only MB to MLO/MLO to MB MB to MLO/MLO to MB Invertible (Indoor) Yes Yes Yes Insta-Wire Neutrals Yes No Yes Outboard Neutrals No Yes No High-Circuitry Yes Yes Yes Trim Mount Tabs Yes Yes Yes Packaging Single-Carton Carton-in-Carton Carton-in-Carton Breakers Siemens Siemens or Murray Siemens 12 12 www.sydist.com www.sydist.com/SiemensMurray Siemens PL Series Load Centers™ Features and Benefits www.usa.siemens.com/loadcenters All devices convertible from main lug to main breaker and vice versa. Invertible for bottom feed application. Mounting tabs on the trim hold it in place on the load center, freeing up both hands to drive the trim screws. All devices are provided with 2 factory installed ground bars. The pre-positioned bond screw eliminates bond strap/screw assemblies, and reduces the risk of losing components in the field. Combination head screw on the neutrals, ground, trim, upper pan, and bond screw provide installation flexibility. The patented INSTAWIRE™ neutral/ ground system allows for faster installation because screws are backed out, ready for wire insertion. The visible neutral and grounds system aids in the insertion of conductors. A rigid, sturdy base pan provides the ruggedness required for the most harsh applications. Copper bus The outdoor enclosure has a slide hinge door for the easiest installation and can be removed by backing out only one screw. PL Series Load Centers ship with trims packaged separately. www.sydist.com www.sydist.com/SiemensMurray 13 PL™ Series Load Centers 1-Phase Main Lug and Main Breaker Load Centers 1-Phase, 3-Wire SN, 120/240 Volts Ac Main Breaker/Convertible Load Centers g Copper Bus 12-70 Circuits / 100-225 Amperes Branch Circuits No. Of Amp Rating Spaces No. Of Circuits 60/75°C Rated 22,000A IR Indoor Enclosure – Nema Type 1 Outdoor Enclosure – Nema Type 3R Enclosure Height Enclosure Height Catalog Number (Inches) Catalog Number (Inches) 100 12 24 P1224B1100CU 18 PW1224B1100CU 21 100 16 24 P1624B1100CU 21 PW1624B1100CU 23 100 20 20 P2020B1100CU 24 PW2020B1100CU 27 100 20 24 P2024B1100CU 24 — — 100 24 24 P2424B1100CU 24 — — 100 30 30 P3030B1100CU 30 — — 100 30 40 — — PW3040B1100CU 35 125 30 30 P3030B1125CU 30 PW3040B1125CU 35 150 20 30 P2030B1150CU 24 — — 150 20 30 — — PW2030B1150CU 27 150 30 30 P3030B1150CU 30 — — 150 30 40 — — PW3040B1150CU 35 200 20 40 P2040B1200CU 30 PW2040B1200CU 27 200 30 40 P3040B1200CU 36 PW3040B1200CU 35 200 30 40 P3040B1200 36 — — 200 40 40 P4040B1200CU 36 PW4040B1200CU 38 200 40 40 P4040B1200 36 — — 200 54 70 P5470B1200CU 44 — — 225 42 60 P4260B1225CU 39 PW4260B1225CU 42 225 54 70 P5470B1225CU 44 — — Single phase factory installed 22kA IR main circuit breaker offers 22/10kA IR series combination rating when using 10kA type QP, QT, QPF, QE, QN, and QAF/QAFC branch breakers. g Main Lug/Convertible Load Centers Copper Bus 12-70 Circuits / 125-225 Amperes 60/75° Rated 100,000A IR Branch Crcuits No. Of Amp Rating Spaces No. Of Circuits Indoor Enclosure - Nema Type 1 Outdoor Enclosure - Nema Type 3R Enclosure Height Enclosure Height Catalog Number (Inches) Catalog Number (Inches) 125 125 125 125 125 125 125 125 150 200 200 200 200 200 200 200 200 200 225 225 225 12 24 24 20 24 40 40 40 30 24 40 40 30 40 40 54 40 40 24 60 70 P1212L1125CU P1224L1125CU P1624L1125CU P2020L1125CU P2024L1125CU P2440L1125CU P3040L1125CU P4040L1125CU P2030L1150CU P1224L1200CU P2040L1200CU P2440L1200CU P3030L1200CU P3040L1200CU P3040L1200 P3054L1200CU P4040L1200CU P4040L1200 — P4260L1225CU P5470L1225CU 12 12 16 20 20 24 30 40 20 12 20 24 30 30 30 30 40 40 12 42 54 Suitable for use as service equipment. May be installed on higher rated systems when protected by a circuit breaker with a higher AIR rating. Indoor enclosures are 14 1/4" wide by 3 7/8" deep. Outdoor enclosures are 14 1/2" wide by 4 1/4" deep. Suitable for use as service entrance equipment when not more than six main disconnecting means are provided. See article 230.71 of the NEC®. 14 14 www.sydist.com www.sydist.com/SiemensMurray g 18 18 21 24 24 24 30 36 24 24 30 30 36 36 36 36 36 36 — 39 44 PW1212L1125CU PW1224L1125CU PW1624L1125CU — — — PW3040L1125CU — PW2030L1150CU PW1224L1200CU PW2040L1200CU — — PW3040L1200CU — PW3054L1200CU PW4040L1200CU — PW1224L1225CU PW4260L1225CU — 21 21 23 — — — 35 — 27 23 27 — — 35 — 35 38 — 23 42 — 125A load centers will accept MBK100A and MBK125A. 150A load centers will accept MBK150A. 200A load centers will accept MBK200A and MBK150A. 225A load centers will accept MBK225A, MBK200A, MBK150A. Copper bus load centers are recommended for those applications where the environment may be severe (i.e. far and coastal areas). Includes all PL Series features with aluminum bussing. Offering a full line of load centers, Siemens meets the needs of every application and all of your installation needs. From small load centers, riser panels and three phase load centers, to the PL and ES Series Load Centers™, Siemens has the highest quality, most complete offering on the market. Focusing on reliability, value and labor savings - Siemens is committed to increase productivity by reducing installation times. ES and PL Series Load Center Video Load Center Mobile Webpage PL™ Series Load Centers 1-Phase Special Load Centers 1-Phase, 3-Wire SN, 120/240 Volts AC Split Ground Series Main Lug Convertible Load Centers 12-60 Circuits / 125-200 Amperes Copper Bus 60/75° Rated, 100,000A IR Branch Circuits Amp Rating No. Of Spaces No. Of Circuits Indoor Enclosure – Nema Type 1 Enclosure Height Catalog Number (Inches) 125 125 125 125 150 200 200 200 200 225 12 16 20 24 20 30 30 40 40 40 24 24 30 30 30 40 40 40 40 60 P1224L1125CUSG P1624L1125CUSG P2030L1125CUSG P2430L1125CUSG P2030L1150CUSG P3040L1200CUSG P3040L1200SG P4040L1200CUSG P4040L1200SG P4260L1225CUSG 18 21 24 24 24 36 36 36 36 39 Split Ground Series Main Breaker Convertible Load Centers Split Ground Load Centers have factory installed 100% neutral with factory bonded 75% ground. No neutral tie strap. Copper Bus 40 Circuits / 200 Amperes 60/75° Rated, 22,000A IR Branch Circuits Amp Rating No. Of Spaces No. Of Circuits Indoor Enclosure – Nema Type 1 Enclosure Height Catalog Number (Inches) 200 40 40 P4040B1200CUSG 36 Outdoor Trailer Panels Copper Bus 16 Circuits / 200 Amperes 60/75° Rated, 22,000A IR Amp Rating No. Of Spaces No. Of Circuits Catalog Number Main Breaker 200 8 16 PW0816L1200TC MBK150A or MBK200A Field Installed 23 200 8 16 PW0816B1200TC MBK200A Factory Installed 23 Enclosure Height (Inches) g Load Centers with White Trim Copper or Aluminum Bus 40 Circuits / 200 Amperes 60/75° Rated 22,000A IR Branch Circuits Indoor Enclosure - Nema Type 1 Amp Rating Main Lug / Main Breaker No. Of Spaces No. Of Circuits Catalog Number Enclosure Height (Inches) 200 200 200 Main Breaker Main Breaker Main Breaker 30 40 40 40 40 40 P3040B1200W P4040B1200W P4040B1200CUW 36 36 36 g Includes all PL Series features with aluminum bussing. Indoor enclosures are 14 1/4" wide by 3 7/8" deep. May be installed on higher rated systems when protected by a circuit breaker with a higher AIR rating. Outdoor enclosures are 14 1/2" wide by 4 1/4" deep. Main lug panel rated 100,000A IR. Load centers with white trim have increased lead time of 3-4 weeks. Sold in pallet quantites only. Load centers with CUW suffix indicates copper bus with white trim. Load centers with W suffix only indicates aluminum bus with white trim. Offering a full line of load centers, Siemens meets the needs of every application and all of your installation needs. From small load centers, riser panels and three phase load centers, to the PL and ES Series Load Centers™, Siemens has the highest quality, most complete offering on the market. Focusing on reliability, value and labor savings - Siemens is committed to increase productivity by reducing installation times. ES and PL Series Load Center Video Load Center Mobile Webpage www.sydist.com www.sydist.com/SiemensMurray 15 PL™ Series Load Centers 3-Phase Main Lug and Main Breaker Load Centers 3-Phase, 3-Wire, 240 Volt AC or 3-Phase, 4-Wire, 120/240 or 120/208 Volts AC Main Breaker/Convertible Load Centers Copper Bus 30-70 Circuits / 100-225 Amperes 60/75°C Rated 22,000A IR Branch Circuits Amp No. Of Rating Spaces No. Of Circuits Indoor Enclosure – Nema Type 1 Outdoor Enclosure – Nema Type 3R Enclosure Height Enclosure Height Catalog Number (Inches) Catalog Number (Inches) 100 100 125 150 150 200 200 225 225 225 24 42 30 42 42 54 60 60 60 70 P1224B3100CU P3042B3100CU P3030B3125CU P2442B3150CU P4242B3150CU P3054B3200CU P4260B3200CU P4260B3225CU P4260B3225TCU P5470B3225CU 12 30 30 24 42 30 42 42 42 54 24 30 39 36 42 39 42 42 49 49 — — — — — PW3054B3200CU PW4260B3200CU — — — — — — — — 38 42 — — — Main Lug/Convertible Load Centers Copper Bus 12-70 Circuits / 125-225 Amperes 60/75° Rated 100,000A IR Branch Circuits Amp No. Of Rating Spaces No. Of Circuits Indoor Enclosure – Nema Type 1 Enclosure Height Catalog Number (Inches) Outdoor Enclosure – Nema Type 3R Enclosure Height Catalog Number (Inches) 125 200 200 225 225 24 42 54 60 70 P1224L3125CU g P2442L3200CU P3054L3200CU P4260L3225CU P5470L3225CU PW1224L3125CU g PW2442L3200CU PW3054L3200CU PW4260L3225CU — 12 24 30 42 54 May be installed on higher rated systems when protected by a circuit breaker with a higher AIR rating. Back fed main breaker. Indoor enclosures are 14 1/4" wide by 3 7/8" deep. Outdoor enclosures are 14 1/2" wide by 4 1/4" deep. Suitable for use as service entrance equipment when not more than six main disconnecting means are provided. See article 230.71 of the NEC®. 21 36 39 42 49 g 21 35 38 42 — Includes factory installed feed through lugs and is also non-convertible. Non-convertible to main breaker. All load centers are provided with tin plated copper bus bars. Rated 100,000A IR in series with breakers listed on wiring diagram. All load centers are provided with tin-plated copper bus bars. Offering a full line of load centers, Siemens meets the needs of every application and all of your installation needs. From small load centers, riser panels and three phase load centers, to the PL and ES Series Load Centers™, Siemens has the highest quality, most complete offering on the market. Focusing on reliability, value and labor savings - Siemens is committed to increase productivity by reducing installation times. ES and PL Series Load Center Video Load Center Mobile Webpage 16 www.sydist.com 16 www.sydist.com/SiemensMurray Rock Solid Load Centers Features The Murray Rock Solid Load Center is the highest quality, most versatile design in the industry. Features on the Rock Solid Load Center include: 1. "Swiss Cheese" style neutral bars provide multiple 1/0 connection points. 1 2. All units include factory installed ground bar and isolated neutral. 3. With the use of the included bonding strap, ground bars and neutral bars can be bonded for service entrance applications. 4. Outboard neutral and groundbars allow for all neutral and ground connections to be located away from breaker connections, making for a neat, clean installation. 2 4 5. Mounting tabs on the trim hold it in place on the load center, freeing up both hands to drive the trim screws. 6. Combination head screw on trim and upper pan screws provide installation flexibility. 7. All devices are convertible from main lug to main breaker or vice versa with the addition of main breaker or main lug kits. 8. All main breakers are straight in wired – no back feeding required. 3 5 11. All indoor Rock Solid Load Centers are invertible for bottom feed applications. 7 8 The following offering is available in the Murray line: 9 10 9. A rigid, sturdy base pan with metal hook rails provides the most rugged breaker connection in the industry. 10. The outdoor enclosure has a slide hinge door for the easiest of installation and can be removed by backing out only one screw. 12-60 Circuits/Spaces Indoor and outdoor enclosures 100 to 225 Amp Main lug and main breaker Value packs - a mix of branch breakers provided with the load center 11 www.sydist.com www.sydist.com/SiemensMurray 17 Rock Solid Load Centers Main Lug Only, 1Ø, 65,000 AIC, Main Lug Panels 3-Wire 120/240V AC or 208Y/120V AC, Insulated and Bonded Split Neutrals Load centers on this page through 225 amp feature a split neutral insulated bars. For service entrance applications, install bonding strap, and use both bars for neutral and ground conductors. For non service entrance applications, do not install bonding strap and use insulated bars for neutral conductors and bonded bar for ground conductors. LW2040L1200 12-42 Circuit, 125–225 Amperes Amps Max. 125 125 125 125 150 150 200 200 200 200 200 225 No. of Spaces 12 16 20 30 16 24 12 20 24 30 40 40 Max. Circuit 24 32 40 40 32 40 24 40 40 40 40 60 Indoor Type 1 Catalog Number LC1224L1125 LC1632L1125 LC2040L1125 LC3040L1125 LC1632L1150 LC2440L1150 — LC2040L1200 LC2440L1200 LC3040L1200 LC4040L1200 LC4060L1225 Dimensions Height Width 21 143⁄8 21 143⁄8 24 143⁄8 30 143⁄8 24 143⁄8 30 143⁄8 — — 30 143⁄8 30 143⁄8 36 143⁄8 39 143⁄8 39 143⁄8 Depth 4 4 4 4 4 4 — 4 4 4 4 4 Outdoor Type 3R Catalog Number LW1224L1125 LW1632L1125 LW2040L1125 — — — LW1224L1200 LW2040L1200 — LW3040L1200 — — Dimensions Height Width 20 141⁄4 29 141⁄4 29 141⁄4 — — — — — — 29 141⁄4 29 141⁄4 — — 38 141⁄4 — — — — Depth 41⁄2 41⁄2 41⁄2 — — — 41⁄2 41⁄2 — 41⁄2 — — Max. Circuit 40 40 40 40 24 42 Indoor Type 1 Catalog Number LC2040L1125CU LC2040L1200CU LC3040L1200CU LC4040L1200CU — LC4242L1225CU Dimensions Height Width 24 143⁄8 30 143⁄8 36 143⁄8 39 143⁄8 — — 42 143⁄8 Depth 4 4 4 4 — 4 Outdoor Type 3R Catalog Number — — — — LW1224L1225CU LW4242L1225CU Dimensions Height Width — — — — — — — — 29 141⁄4 42 141⁄4 Depth — — — — 41⁄2 41⁄2 Copper Bus Amps Max. 125 200 200 200 225 225 No. of Spaces 20 20 30 40 12 42 Convertible to main breaker by using the following main breaker kits: 100A load centers: MBK100M only. 125A load centers: MBK100M and MBK125M only. 150A load centers: MBK150M only. 200A load centers: MBK150M and MBK200M only. 225A load centers: MBK150M, MBK200M, and MBK225M only. 100-225A only. Standard package quantity equal to 1. 18 18 www.sydist.com www.sydist.com/SiemensMurray Dimensions shown are representative of outside box length, width & depth (± 18⁄ ”) and do not include allowance for mounting bumps, endwalls, hubs or hardware protrusions. Allow approximately 114⁄ ” additional in length and width dimensions for surface or combination overhang. Consult factory for specific details if required. Hub provision only. Closure plate included. Panels through 225A require HS type hub; panels over 225A require HV type hub. See accessories page <?> for hub selection. Copper bus load centers are recommended for those applications where the environment may be severe (ie farm and coastal areas). Rock Solid Load Centers Main Breaker, 1Ø, 22,000 AIC Load centers on this page through 200 amp feature a new split neutral with one bonded and one insulated bar. For service entrance applications, install bonding strap, and use both bars for neutral and ground conductors. For non service entrance applications, do not install bonding strap and use insulated bar for neutral conductors and bonded bar for ground conductors. Load Center Short Circuit Current Rating Murray load centers have UL recognized short circuit current ratings up to 100,000 Amps, when used with appropriate main or feeder (remote or internal) overcurrent devices. Load center ratings are shown below. For load center applications with residential or commercial metering equipment, refer to the appropriate catalog section. 1Ø, main breaker load centers are Underwriter’s Laboratories Listed for use with 60/75°C conductors and accept Murray branch circuit breakers which are also UL Listed for use with 60/75°C conductors. Type 3R load centers are furnished with a hub opening closure plate. LC2040B1200 Load Center Short Circuit Current Rating Load Center Short Circuit Current Rating 10,000 AIC 22,000 AIC 42,000 AIC 65,000 AIC 100,000 AIC 100,000 AIC Load Center Main Rating Internal or Remote Main or Feeder Circuit Breaker Type Any 100/125A 150/200/225A 100/125A 150/200/225A 100/125A 150/200/225A 100/125A 150/200/225A Any MP-HT, MQH MD-H, MQHbd, MPP-HT MQL MQL MP-MT, MPP-MT MPP-MTc 100A, 300V AC, Class “T” Fuse 200A, 300V AC, Class “T” Fuse 12-42 Circuit, 100-200 Amperes Amps Max. 100 100 100 100 100 150 150 150 150 200 200 200 200 200 200 200 200 200 No. of Spaces 12 16 20 24 30 16 20 24 30 12 16 20 24 30 40 30 40 40 Max. Circuit 24 32 40 40 40 32 40 40 40 24 32 40 40 40 40 54 40 60 Catalog Number Dimensions Indoor Type 1g LC1224B1100 — LC2040B1100 LC2440B1100 LC3040B1100 LC1632B1150 LC2040B1150 LC2440B1150 LC3040B1150 — LC1632B1200 LC2040B1200 LC2440B1200 LC3040B1200 LC4040B1200 LC3054B1200 LC4040B1200 LC4060B1200 Height 18 — 24 24 30 24 30 30 36 — 30 30 30 36 39 36 39 401⁄2 Width 143⁄8 — 143⁄8 143⁄8 143⁄8 143⁄8 143⁄8 143⁄8 143⁄8 — 143⁄8 143⁄8 143⁄8 143⁄8 143⁄8 143⁄8 143⁄8 157⁄8 Depth 4 — 4 4 4 4 4 4 4 — 4 4 4 4 4 4 4 5 Outdoor Type 3Rg Dimensions Catalog Number LW1224B1100 LW1632B1100 — — — — LW2040B1150 — — LW1224B1200 — LW2040B1200 — LW3040B1200 LW4040B1200 — — — Height 23 23 — — — — 29 — — 29 — 29 — 38 38 — — — Width 141⁄4 141⁄4 — — — — 141⁄4 — — 141⁄4 — 141⁄4 — 141⁄4 141⁄4 — — — Depth 41⁄2 41⁄2 — — — — 41⁄2 — — 41⁄2 — 41⁄2 — 41⁄2 41⁄2 — — — Copper Bus Dimensions Amps Max. No. of Spaces Max. Circuit Indoor Type 1g Catalog Number 100 20 40 LC2040B1100CU 24 200 20 40 LC2040B1200CU 30 200 30 40 LC3040B1200CU 200 40 40 LC4040B1200CU 100-225A only. information is based on use of 10,000 AIC rated branch circuit breakers in load center (MP-T, MH-T, MP-GT, MG). Most series ratings exclude MH-T above 40 Amp. Consult device wiring diagram for specific data. Remote Only Types MQH & MQL may be mounted internal in 150-225 amp 3Ø main breaker load centers. This Height Width 143⁄8 Depth 4 36 143⁄8 143⁄8 39 143⁄8 4 Dimensions 4 4 shown are representative of outside box length, width & depth (±18⁄ ”) and do not include allowance for mounting bumps, endwalls, hubs or hardware protrusions. Allow approximately 114⁄ ” additional in length and width dimensions for surface or combination overhang. Consult factory for specific details if required. Hub provision only. Closure plate included. Panels through 225A require HS type hub; panels over 225A require HV type hub. g Standard package quantity equal to 1. bus load centers are recommended for those applications where the environment may be severe (ie farm and coastal areas). Copper www.sydist.com www.sydist.com/SiemensMurray 19 Siemens ES Series Load Centers™ Features and Benefits www.usa.siemens.com/loadcenters Main breaker convertible to main lug but main lug not convertible. Invertible for bottom feed application. Ground bar field installed (select skus with “G” suffix will have ground bar factory installed). The pre-positioned bond screw eliminates bond strap/screw assemblies, and reduces the risk of losing components in the field. Combination head screw on the neutrals, ground, trim, upper pan, and bond screw provide installation flexibility. The patented INSTAWIRE™ neutral/ground system allows for faster installation because screws are backed out, ready for wire insertion. The visible neutral and grounds system aids in the insertion of conductors. Single side inboard neutral on 24 circuits and below; dual on 30 circuits and above. A rigid, sturdy base pan provides the ruggedness required for the most harsh applications. ES Series Load Centers ship in single piece carton. The outdoor enclosure has a slide hinge door for the easiest installation and can be removed by backing out only one screw. 20 20 www.sydist.com www.sydist.com/SiemensMurray Mounting tabs on the trim hold it in place on the load center, freeing up both hands to drive the trim screws. Aluminum bus ES™ Series Load Centers 1-Phase Main Lug and Main Breaker Load Centers 1-Phase, 3-Wire SN, 120/240 Volts AC Main Breaker/Convertible Load Centers 12-70 circuits / 100-225 amperes Branch Circuits Amp Rating No. Of Spaces 100 10 100 12 100 16 100 20 100 20 100 30 125 12 125 16 125 16 125 24 125 30 125 30 150 16 150 20 150 24 150 30 150 30 150 40 200 16 200 20 200 24 200 30 200 40 200 54 225 42 225 54 No. Of Circuits 20 24 24 20 24 30 24 24 32 24 30 40 30 30 30 30 40 40 32 40 40 40 40 70 60 70 Indoor Enclosure – Nema Type 1 Catalog Enclosure Height Number (Inches) S1020B1100 18 S1224B1100 18 S1624B1100 21 S2020B1100 24 S2024B1100 24 S3030B1100 30 — — S1624B1125 21 — — S2424B1125 24 S3030B1125 30 S3040B1125 30 S1630B1150 24 S2030B1150 24 S2430B1150 30 S3030B1150 30 S3040B1150 30 — — S1632B1200 24 S2040B1200 30 S2440B1200 30 S3040B1200 36 S4040B1200 36 S5470B1200 44 S4260B1225 39 S5470B1225 44 Main Lug/Non-Convertible Load Centers 12-70 circuits / 125-225 amperes Branch Circuits Amp Rating No. Of Spaces 125 12 125 12 125 16 125 20 125 20 125 20 125 20 125 24 125 24 125 24 125 30 125 30 125 40 150 20 200 12 200 20 200 24 200 30 200 30 200 30 200 40 225 12 225 42 225 54 No. Of Circuits 12 24 24 20 20 24 24 24 24 40 40 40 40 30 24 40 40 30 40 54 40 24 60 70 Aluminum Bus 60/75°C rated 22,000A IR Outdoor Enclosure – Nema Type 3R Catalog Enclosure Height Number (Inches) — — SW1224B1100 21 SW1624B1100 23 SW2020B1100 27 — — — — SW1224B1125 21 — — SW2024B1125 27 SW2424B1125 27 — — SW3040B1125 35 — — — — — — — — SW3040B1150 35 SW4040B1150 38 — — SW2040B1200 27 — — SW3040B1200 35 SW4040B1200 38 — — SW4260B1225 42 — — Aluminum Bus Main Breaker Main Lug 60/75° rated 100,000A IR Indoor Enclosure - Nema Type 1 Catalog Enclosure Height Number (Inches) S1212L1125 18 18 S1224L1125 S1624L1125 21 S2020L1125 21 21 S2020L1125G S2024L1125 21 21 S2024L1125G S2424L1125 24 24 S2424L1125G S2440L1125 24 S3040L1125 30 30 S3040L1125G S4040L1125 36 S2030L1150 24 21 S1224L1200 S2040L1200 24 S2440L1200 30 S3030L1200 30 S3040L1200 30 S3054L1200 30 S4040L1200 36 — — S4260L1225 36 S5470L1225 42 Outdoor Enclosure - Nema Type 3R Catalog Enclosure Height Number (Inches) SW1212L1125 21 SW1224L1125 21 SW1624L1125 21 — — — — — — — — SW2424L1125 27 — — — — SW3040L1125 29 — — — — SW2030L1150 27 SW1224L1200 21 SW2040L1200 27 — — — — SW3040L1200 35 SW3054L1200 35 SW4040L1200 35 SW1224L1225 23 SW4260L1225 38 — — Suitable for use as service equipment. May be installed on higher rated systems when protected by a circuit breaker with a higher AIR rating. Indoor enclosures are 14 1/4" wide by 3 7/8" deep. Outdoor enclosures are 14 1/2" wide by 4 1/4" deep. Suitable for use as service entrance equipment when not more than six main disconnecting means are provided. See article 230.71 of the NEC®. ES Series single phase skus with a "G" suffix have ground bar included (factory installed). Offering a full line of load centers, Siemens meets the needs of every application and all of your installation needs. From small load centers, riser panels and three phase load centers, to the PL and ES Series Load Centers™, Siemens has the highest quality, most complete offering on the market. Focusing on reliability, value and labor savings - Siemens is committed to increase productivity by reducing installation times. ES and PL Series Load Center Video Load Center Mobile Webpage www.sydist.com www.sydist.com/SiemensMurray 21 ES™ Series Load Centers 1-Phase Special Load Centers 1-Phase, 3-Wire SN, 120/240 Volts AC Load Centers With White Trim Aluminum Bus 16-40 circuits / 100 – 200 amperes 60/75° rated 100,000A IR Branch Circuits Amp Main Lug / Rating Main Breaker No. Of Spaces Indoor Enclosure – Nema Type 1 No. Of Catalog Circuits Number 100 16 24 Main breaker S1624B1100W Enclosure Height (Inches) 21 125 Main lug 20 20 S2020L1125W 21 125 Main lug 24 24 S2424L1125W 24 200 Main lug 30 30 S3030L1200W 30 125 Main lug 30 40 S3040L1125W 30 200 Main breaker 40 40 S4040B1200W Amp Rating Main Breaker No. Of Spaces No. Of Circuits Catalog Number Enclosure Height (Inches) 200 8 16 SW0816L1200T 23 36 Outdoor Trailer Panels 16 circuits / 200 amperes 200 N/A MBK200A 8 16 Main Lug / Amp Rating Main Breaker No. Of Spaces No. Of Circuits Catalog Number Breakers Included 100 Main breaker 20 20 S2020B1100P (3) Q120, (1) Q230 200 Main breaker 30 40 S3040B1200P (3) Q120, (1) Q230 200 Main lug 30 40 S3040L1200P (3) Q120, (1) Q230 200 Main breaker 40 40 S4040B1200P (3) Q120, (1) Q230 Value Pack Load Centers SW0816B1200T 23 Aluminum Bus Split Ground Series Load Centers 30-40 Circuits / 125-200 Amperes 16 circuits / 200 amperes Aluminum Bus Branch Circuits Amp Main Lug / Rating Main Breaker No. Of Spaces No. Of Circuits Indoor Enclosure – Nema Type 1 Enclosure Height Catalog Number (Inches) 125 Main lug 20 30 S2030L1125SG 21 150 Main breaker 30 30 S3030B1150SG 30 200 Main breaker 40 40 S4040B1200SG 36 Load centers with white trim have increased lead time of 3-4 weeks. Sold in pallet quantities only. Additional charge will apply. Contact sales office for details. Indoor enclosures are 14 1/4" wide by 3 7/8" deep. Breakers are shipped inside a sleeve located inside the load center. Outdoor enclosures are 14 1/2" wide by 4 1/4" deep. Main breaker rated 22,000A IR. Split Ground load centers have factory installed 100% neutral with factory bonded 75% ground. Offering a full line of load centers, Siemens meets the needs of every application and all of your installation needs. From small load centers, riser panels and three phase load centers, to the PL and ES Series Load Centers™, Siemens has the highest quality, most complete offering on the market. Focusing on reliability, value and labor savings - Siemens is committed to increase productivity by reducing installation times. 22 22 www.sydist.com www.sydist.com/SiemensMurray ES and PL Series Load Center Video Load Center Mobile Webpage ES™ Series Load Centers 3-Phase Main Lug and Main Breaker Load Centers 3-Phase, 3-Wire, 240 Volt AC or 3-Phase, 4-Wire, 120/240 or 120/208 Volts AC Main Breaker/Convertible Load Centers Aluminum Bus 30-60 circuits / 100-225 amperes 60/75°C rated 10,000A IR Branch Circuits Amp No. Of Rating Spaces No. Of Circuits Indoor Enclosure – Nema Type 1 Catalog Enclosure Height Number (Inches) Outdoor Enclosure – Nema Type 3R Catalog Enclosure Height Number (Inches) 100 12 24 S1224B3100 24 — — 100 30 30 S3030B3100 30 — — 100 30 42 S3042B3100 30 — — 150 24 42 S2442B3150 36 SW2442B3150 35 150 42 42 S4242B3150 42 — — 200 30 54 S3054B3200 39 SW3054B3200 38 200 42 60 S4260B3200 42 SW4260B3200 42 225 42 42 S4242B3225 42 SW4242B3225 42 Main Breaker/Non-Convertible Load Centers Aluminum Bus 12-70 circuits / 125-225 amperes 60/75° Rated 100,000A IR g Branch Circuits Amp No. Of Rating Spaces No. Of Circuits Indoor Enclosure – Nema Type 1 Catalog Enclosure Height Number (Inches) Outdoor Enclosure – Nema Type 3R Catalog Enclosure Height Number (Inches) 125 24 S1224L3125 SW1224L3125 12 21 21 150 18 36 S1836L3150 24 SW1836L3150 23 150 24 42 S2442L3150 30 SW2442L3150 27 200 12 24 S1224L3200 21 SW1224L3200 21 200 24 42 S2442L3200 30 SW2442L3200 27 200 30 54 S3054L3200 30 SW3054L3200 35 225 42 60 S4260L3225 36 SW4260L3225 38 225 54 70 S5470L3225 42 — — May be installed on higher rated systems when protected by a circuit breaker with a higher AIR rating. Back fed main breaker. Indoor enclosures are 14 1/4” wide by 3 7/8” deep. Outdoor enclosures are 14 1/2” wide by 4 1/4” deep. Non-convertible to main breaker. Suitable for use as service entrance equipment when not more than six main disconnecting means are provided. See article 230.71 of the NEC®. g Rated 100,000A IR in series with breakers listed on wiring diagram. Offering a full line of load centers, Siemens meets the needs of every application and all of your installation needs. From small load centers, riser panels and three phase load centers, to the PL and ES Series Load Centers™, Siemens has the highest quality, most complete offering on the market. Focusing on reliability, value and labor savings - Siemens is committed to increase productivity by reducing installation times. ES and PL Series Load Center Video Load Center Mobile Webpage www.sydist.com www.sydist.com/SiemensMurray 23 Plug-In Circuit Breakers Combination Type Arc-Fault Circuit Interrupters Type QP with INSTA-WIRETM Continuous Current Rating @ 40°C 1- Pole 120/240V AC Catalog Number 2 - Pole 120/240V AC Common Trip Catalog Number 2 - Pole 240V AC Common Trip Catalog Number 15 Q115 Q215 Q215R 15 10kA 20 Q120 Q220 Q220R 20 10kA 25 Q125 Q225 – 15 22kA 30 Q130 Q230 Q230R 20 22kA 35 Q135 g Q235 – 15 65kA 40 Q140 Q240 Q240R 20 65kA 45 Q145 g Q245 – 50 Q150 Q250 Q250R 60 Q160 Q260 Q260R 70 Q170 Q270 Q270R Ampere Rating Interrupting Rating 80 – Q280 – 15 10kA 90 – Q290 – 20 10kA 100 – Q2100 Q2100R 15 22kA 110 – Q2110 – 20 22kA 125 – Q2125 Duplex Plug-In Circuit Breakers Breaker Type QT 1-Pole 10k AIC 120V AC Ampere Rating Interrupting Rating Ul Type QAF2 QAFH2 HQAF2 Catalog Number QA115AFC QA120AFC QA115AFCH QA120AFCH QA115AFCHH QA120AFCHH 2-Pole Plug-In Combination Type Arc-Fault Circuit Interrupters Ul Type QAF QAFH Catalog Number Q215AFC Q220AFC Q215AFCH Q220AFCH Ground-Fault Circuit Interrupters Ampere Rating 2-Pole Catalog Number 15-15 Q1515 15-20 Q1520 20-20 Q2020 20-30 Q2030 15-30 Q3015 20-30 Q3020 30-30 Q3030 Breaker Type QPF 1-Pole 120V AC Plug-in g UL listed as SWD (switching duty) rated. Suitable for 120V AC fluorescent lighting. HACR rated. For 22k AIC add “H” suffix. For 65k AIC add “HH” suffix. Contact factory for availability. White line neutral (pigtail) must be connected to the panel neutral for the device to function. g Built to order. Allow 2-3 weeks for delivery. Built to order. Allow 2–3 weeks for delivery. 24 24 www.sydist.com www.sydist.com/SiemensMurray 1-Pole Plug-In Combination Type Arc-Fault Circuit Interrupters QPF 2-Pole 120/240V AC Plug-in Ampere Rating Catalog Number 15 QF115 20 QF120 25 QF125 g 30 QF130 15 QF215 20 QF220 30 QF230 40 QF240 50 QF250 60 QF260 Plug-In Circuit Breakers cont. Triplex Plug-In Circuit Breakers Breaker Type QT 2-Pole 10k AIC 120/240V AC center common trip Ampere Rating 2-Pole 1-Pole Catalog Number 15 15 Q21515CT 15 20 Q21520CT 15 25 Q21525CT 15 30 Q21530CT 15 35 Q21535CT 15 40 Q21540CT 15 45 Q21545CT 15 50 Q21550CT 20 20 Q22020CT 20 25 Q22025CT 20 30 Q22030CT 20 35 Q22035CT 20 40 Q22040CT 20 45 Q22045CT 20 50 Q22050CT 30 30 Q23030CT Quadplex Plug-In Circuit Breakers QT 2-Pole 10k AIC 120/240V AC common trip Breaker Type QN 2-Pole 120/240V AC QNH 2-Pole 120/240V AC HQN 2-Pole 120/240V AC Ampere Rating Catalog Number 150 QN2150 175 QN2175 Catalog Number QN2150R QN2175R 200 QN2200 QN2200R 150 QN2150H QN2150RH 175 QN2175H QN2175RH 200 QN2200H QN2200RH 150 HQN2150 HQN2150R 175 HQN2175 HQN2175R 200 HQN2200 HQN2200R Main Breaker Kits Description Catalog Number Main breaker kit 100A 1PH QP 240V 22K MBK100A Main breaker kit 125A 1PH QP 240V 22K MBK125A Main breaker kit 150A 1PH QP 240V 22K MBK150A Main breaker kit 200A 1PH QP 240V 22K MBK200A Main breaker kit 225A 1PH QP 240V 22K MBK225A Main breaker kit 100A 3PH QP 240V 10K MBK3100 Main breaker kit 150A 3PH QP 240V 10K MBK3125 Main breaker kit 150A 3PH 240V 10K MBK3150 Main breaker kit 175A 3PH 240V 10K MBK3175 Main breaker kit 200A 3PH 240V 10K MBK3200 Inside 2-Pole Outside 2-Pole Catalog Number Main breaker kit 225A 3PH 240V 10K MBK3225 Main breaker kit 125A 3PH 240V 22K MBK3125H 15 15 Q21515CT2 Main breaker kit 150A 3PH 240V 22K MBK3150H 15 20 Q22020CT2 Main breaker kit 175A 3PH 240V 22K MBK3175H 20 30 Q22030CT2 Main breaker kit 200A 3PH 240V 22K MBK3200H 20 40 Q22040CT2 Main breaker kit 225A 3PH 240V 22K MBK3225H 30 30 Q23030CT2 Main breaker kit 125A 3PH 240V 42K MBK3125HH 30 40 Q23040CT2 Main breaker kit 150A 3PH 240V 42K MBK3150HH 40 40 Q24040CT2 Main breaker kit 175A 3PH 240V 42K MBK3175HH 50 30 Q25030CT2 Main breaker kit 200A 3PH 240V 42K MBK3200HH Main breaker kit 225A 3PH 240V 42K MBK3225HH Ampere Rating Breaker Type Large Branch Circuit Breakers Ground Bar Kits (For Es And Pl Load Centers) Hubs Description Catalog Number Ground bar kit - 8 pos EC1GB8 Description Catalog Number Ground bar kit - 8 pos, 2/0 lug EC1GB82 HS type closure plate ECHS000 Ground bar kit - 12 pos EC2GB12 HS type hub - 3/4” ECHS075 Ground bar kit - 12 pos, 2/0 lug EC2GB122 HS type hub - 1” ECHS100 Ground bar kit - 15 pos EC2GB15 HS type hub - 1 1/4” ECHS125 Ground bar kit - 15 pos, 2/0 lug EC2GB152 HS type hub - 1 1/2” ECHS150 Ground bar kit - 21 pos EC3GB21 HS type hub - 2” ECHS200 EC3GB212 HS type hub - 2 1/2” ECHS250 Ground bar kit - 27 pos EC3GB27 HA type closure plate ECHA000 Ground bar kit - 27 pos, 2/0 lug EC3GB272 HA type hub - 3/4” ECHA075 Ground bar kit - 30 pos EC3GB30 HA type hub - 1” ECHA100 Ground bar kit - 30 pos, 2/0 lug EC3GB302 HA type hub - 1 1/4” ECHA125 EC3GB352 HA type hub - 1 1/2” ECHA150 HV type closure plate ECHV000 HV type hub - 2” ECHV200 HV type hub - 2 1/2” ECHV250 HV type hub - 3” ECHV300 HV type hub - 3 1/2” ECHV350 Ground bar kit - 21 pos, 2/0 lug Ground bar kit - 35 pos, 2/0 lug HACR rated. For 22k AIC add “H” suffix. Reverse handle. Built to order. Allow 2-3 weeks for delivery. For 65k AIC add “H” prefix. HV type hub - 4” ECHV400 www.sydist.com www.sydist.com/SiemensMurray 25 AC Disconnects Ac Disconnects Ac Disconnects With GFCI Receptacle 10,000A Ic Rated, Outdoor Type 3 Outdoor Type 3R 1 Phase Description 120/240V AC Catalog Number Pallet Quantity 60A Non-Fused WN2060 360 60A Fused WF2060 216 30A Fused WF2030 360 60A Non-automatic switch WNAS2060 360 Plastic AC Disconnects 10,000A IC rated 1 Phase 120/240V AC Description Catalog Number Pallet Quantity 60A Non-Fused WN2060PL 360 60A Fused WF2060PL 216 30A Fused WF2030PL 216 26 26 www.sydist.com www.sydist.com/SiemensMurray 1 Phase 120/240V AC Catalog Number Pallet Quantity 60A Non-Fused with 15A GFCI receptacle WN2060GFCI 144 60A Fused with 15A GFCI receptacle WF2060GFCI 112 30A Fused with 15A GFCI receptacle WF2030GFCI 112 Non-automatic switch with 15A GFCI receptacle WNAS2060GFCI 144 Description Fuses not included. To order in pallet quantities, place a “BP” at the end of the catalog number when ordering. Example: WN2060 WN2060BP. EQ Load Centers EQ Load Centers 1 Phase. 3 Wire SN 120/240V AC Breaker Used Indoor Enclosure - Nema Type 1 Outdoor Enclosure - Nema Type 3R Dimensions (Inches) Frame Type QP, QPH, HQP QN, QNH, HQN QPP, QPPH, HQPP, QP Dimensions (Inches) Ampere Rating No. Of Poles Catalog Number Std. Pkg. H W D Catalog Number Std. Pkg. H W D 60 2 E0204ML1060S 5 9 7/8 5 1/8 2 5/8 W0204ML1060 5 8 5 4 1/4 60 2 E0204ML1060F 5 9 7/8 5 1/8 2 5/8 - - - - - 100 2 E0202MB1100 1 17 1/8 7 3/8 4 5/16 W0202MB1100CU 1 17.4 7.3 4.3 125 2 E0204ML1125SCU 1 17 1/8 7 1/8 4 1/4 W0204ML1125CU 1 17 1/8 7 3/8 4 5/16 150 2 - - - - - W0202MB1150CU 1 19 3/4 8.4 4.6 200 2 - - - - - W0202ML1200CU 1 19 3/4 8.4 4.6 200 2 E0202MB1200 - 19 3/8 8 1/2 4 W0202MB1200CU 1 19 3/4 8.4 4.6 225 1-4 - - - - - W0406ML1225CU 1 23 10 4 1/8 Will not accommodate 2-pole GFCI or circuit breaker with shunt trip. 42,000A IR maximun. Copper wire only at 225A. Main breaker factory installed. CSA Listed. www.sydist.com www.sydist.com/SiemensMurray 27 Schaedler Yesco Distribution, Inc. 3982 Paxton St. Harrisburg, PA 17111 www.sydist.com Siemens Industry, Inc. 5400 Triangle Parkway Norcross, GA 30092 1-800-241-4453 info.us@siemens.com Subject to change without prior notice Order No. PDSA-SCHYS-0115 Printed in USA All rights reserved © 2015 Siemens Industry, Inc. www.usa.siemens.com/powerdistribution The information provided in this brochure contains merely general descriptions or characteristics of per formance which in actual case of use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.