Mini Starlight

advertisement
MINI STARLIGHT
®
Semi recessed star light
v.162223
LIGHTING DATA (Based on a generic 20W Tungsten Halogen GU4 lamp)
Lamp Lumens
380 lm
Lamp Efficacy
19 lm/W
Colour Temperature
2900K
CIE CRI available as
100
Lifetime L70/B10
≤2,000 hrs
ELECTRICAL INFORMATION
Wattage
Lamp Type
Product Class
NORMAL
MAX
220V AC
240V AC
20W
20W
Tungsten Halogen
III (SELV)
CONNECTIONS AND MECHANICAL
Weight
50 g
IP Rating
IP20
Technical data figures are for guidance only and are subject to ±5% tolerance
PRODUCT CODES
A151301
Black
A151302
Bright Brass
A151305
Bright Chrome
A151307
Satin Chrome
A151308
P1210XX
Minimum recess depth 30
cut-out ø 32
30
White
bezel
ø 42
Dimensions in mm. Not to scale
This luminaire is
compable with bulbs
of the energy classes:
A++
A+
A
B
C
D
E
The luminaire is sold with a bulb
of the energy class: B
874/2012
Designed in-house in the UK supporting British manufacturing
Copyright © John Cullen Lighting 2016. John Cullen Lighting reserve the right to change the design and specification of our product range without prior notice. E&OE
Voltage
MINI STARLIGHT
INSTALLATION GUIDE
®
TURN OFF MAINS SUPPLY BEFORE
STARTING INSTALLATION
DO NOT CONNECT DIRECTLY TO MAINS SUPPLY
Cut-out - Standard
USING A CLEAN SHARP HOLE SAW CUT THE REQUIRED
HOLESIZE.
WIRE IN SERIES: CORRECT POLARITY
MUST BE OBSERVED
LED MUST NOT BE INSTALLED IN A LOCATION
WHERE AMBIENT TEMPERATURE EXCEEDS 40°C
WWW.JOHNCULLENLIGHTING.CO.UK
X mm Ø CUT-OUT
Test
TURN BACK ON MAINS SUPPLY
POWER FITTINGS ON AND TEST TO SEE IF
LIGHT FITTING WORKS CORRECTLY
Complete
LOCATE FITTING INTO HOLE
NOTES
PLEASE NOTE:-These notes are for guidance only. John Cullen accepts no responsibility for any installation using the above and the final decision on installation
remains with the installer. All electrical works to be carried out by a qualified electrician.
Copyright © John Cullen Lighting 2016. John Cullen Lighting reserve the right to change the design and specification of our product range without prior notice. E&OE
Y mm RECESS DEPTH
USE ONLY JOHN CULLEN APPROVED DRIVER
FIND A SUITABLE PLACE TO HIDE THE
TRANSFORMER (WHICH CAN BE ACCESSED FOR
MAINTENANCE) FEED CABLE TO FITTING LOCATIONS
AND CONNECT SUPPLY FROM TRANSFORMER
TURN OFF MAINS POWER SUPPLY
BEFORE STARTING INSTALLATION
REFER TO THE PRODUCT SPECIFICATION SHEET
FOR X AND Y DIMMENSIONS
DO NOT WIRE WHEN DRIVER IS ENERGISED AS
LED HOT CONNECTION WILL DESTROY LED
Feed cable
Turn off
v.162223
WARNING
Download