ZoneDefender 80kA power surge protection for small distribution panels, tower lights, equipment cabinets and confined spaces AC or DC application Straightforward and simple installation -- wall or flush mounting LED status indication via solid state diagnostics plus remote indication contacts Thermal and short circuit fusing UL 1449 2nd Edition Listed 10 year product warranty The ZoneDefender Series of power surge protection devices has been specifically designed for interior lighting and small distribution panels. These compact and durable devices offer cost effective, high capacity protection along with application versatility, features which make the Series the ultimate surge protection solution. ZoneDefender units, with a 80kA surge handling capability per phase, provide protection between Line to Neutral, Line to Ground, Line to Line and Neutral to Ground. Utilizing Metal Oxide Varistor (MOV) technology, the ZoneDefender’s protection circuits are highly reliable, dual-redundant varistor networks ensuring your site is never unprotected. Fully automatic in operation, ZoneDefender reacts immediately, clamping voltage surges without causing undue leakage losses under normal operation. No operator intervention is required, ZoneDefender resets automatically and is maintenance free. Suitable for AC or DC applications, ZoneDefender devices provide protection for AC or DC power supplies with no restriction to the amount of load current. ZoneDefender DC versions are available utilizing SAD (Silicon Avalanche Diode) technology in addition to the standard MOVs. DC versions are also available with EMI filtering, should this be required. Thermal fusing is incorporated into each ZoneDefender as an additional safety feature. Short circuit protection is also supplied, as standard, for added peace of mind. Installation is simple - the NEMA 4X enclosure of ZoneDefender devices can be easily ‘wall mounted’. Alternatively, ZoneDefender units may be flush mounted by way of an optional mounting plate which should be specified at time of order placement. The ZoneDefender Series is UL 1449 2nd Edition Listed and boasts an unrivalled 10 year ‘no questions asked’ manufacturers product warranty. Zone-Defender devices also exceed the requirements of ANSI/IEEE C62.45 and ANSI/IEEE C62.41. ZoneDefender offers an LED Status indication facility allowing each varistor network to be continually monitored and indicated by LEDs on the front panel of the device. In addition, remote monitoring is enabled by the units’ remote indication contacts. AC & DC Power Protection Specification All figures typical at 77°F (25°C) unless otherwise stated Model Maximum surge current 80kA (8/20µs)* *except ZoneDefender DC versions. See specifications table for details. Lines protected AC L-N, L-G, L-L, N-G Lines protected DC V+, VAmbient temperature limits –40°F to +185°F (–40°C to +85°C) -working Humidity 95% RH (non-condensing) Enclosure NEMA 1, 2, 3, 3R, 4, 4X, 12 and 13 (IP66) Terminals 12 AWG (3mm2) Mounting Surface mount by 0.21” (5mm) diameter holes or flush mount via mounting plate (Optional at time of order) Remote contacts NC 250Vac, 5A rated Indication Green LED on Protection present Green LED off Internal failure Weight Three phase units 3.6 lbs (1.64Kg) Split phase units 2.0 lbs (0.91Kg) Single phase units 1.9 lbs (0.86Kg) Dimensions Three phase units 5.3” x 5.3” x 2.3” (134.5mm x 134.5mm x 58.4mm) Split phase units & single phase units 4.5” x 2.9” x 2.5” (114.3mm x 73.6mm x 63.5mm) EMC compliance BS EN 60950: 1992 BS EN 61000-6-2: 1999 AC versions 14400 14401 14402 14404 14406 14407 14408 14409 DC versions 14612 14624 14648 14712 14724 14748 14812 14824 14848 Working voltage (V) UL1449 Listing (V) 120 120/240 split* 120/208 277/480 480 220/380 240/415 220 400 400 400 700 1500 700 700 700 435 435 435 890 1600 790 890 790 730 730 730 1200 2100 1200 1200 1200 12V DC 24V DC 48V DC 12V DC 24V DC 48V DC 12V DC 24V DC 48V DC N/A N/A N/A N/A N/A N/A N/A N/A N/A 120 140 280 120 140 280 120 140 280 292 340 504 292 340 504 292 340 504 * Suitable for US use only Let-through voltage @ 3kA @ 10kA (V) (V) Max. continuous operating voltage (Vac) 140 140 140 320 550 275 320 275 Max. surge current 15kA 36kA 53kA 15kA 36kA 53kA 15kA 36kA 53kA Phase types Single phase 2-wire Split phase 3-wire Three phase 4-wire WYE Three phase 4-wire WYE Three phase 3-wire Delta Three phase 4-wire WYE Three phase 4-wire WYE Single phase 2-wire ------------EMI filter EMI filter EMI filter EMI filter & remote LED EMI filter & remote LED EMI filter & remote LED 8/20µs waveform - Tested as per ANSI/IEEE C62.45 and ANSI/IEEE C62.41 AC three phase connection AC single phase connection Figure 1 AC connection details To order specify As per table above. Note: In accordance with our policy of continuous improvement, we reserve the right to change the product’s specification without notice. DC connections Figure 2 DC connection details Approvals A member of the MTL Instruments Group plc Standard/Authority Approved for Product United States Canada UL 1449 2nd Edition Listed AC power product 14400, 14401, 14402, 14404, (C-UL US Listed) 14406, 14407, 14408, 14409 Rev D 02/05/04 Atlantic Scientific Corporation 4300 Fortune Place, Suite A W. Melbourne, FL 32904 USA Tel: +1 800-544-4737, +1 321-725-8000 Fax: +1 321-727-0736 E-mail: sales@atlanticscientific.com, Web: www.atlanticscientific.com Country