80kA power surge protection for small distribution panels,
tower lights, equipment cabinets and confined spaces
AC or DC application
Straightforward and simple installation -- wall
or flush mounting
LED status indication via solid state
diagnostics plus remote indication contacts
Thermal and short circuit fusing
UL 1449 2nd Edition Listed
10 year product warranty
The ZoneDefender Series of power surge
protection devices has been specifically
designed for interior lighting and small
distribution panels. These compact and
durable devices offer cost effective, high
capacity protection along with application
versatility, features which make the Series
the ultimate surge protection solution.
ZoneDefender units, with a 80kA surge
handling capability per phase, provide
protection between Line to Neutral, Line to
Ground, Line to Line and Neutral to Ground.
Utilizing Metal Oxide Varistor (MOV)
technology, the ZoneDefender’s protection
circuits are highly reliable, dual-redundant
varistor networks ensuring your site is never
unprotected. Fully automatic in operation,
ZoneDefender reacts immediately, clamping
voltage surges without causing undue
leakage losses under normal operation. No
operator
intervention
is
required,
ZoneDefender resets automatically and is
maintenance free.
Suitable for AC or DC applications,
ZoneDefender devices provide protection for
AC or DC power supplies with no restriction
to the amount of load current. ZoneDefender
DC versions are available utilizing SAD
(Silicon Avalanche Diode) technology in
addition to the standard MOVs. DC versions
are also available with EMI filtering, should
this be required.
Thermal fusing is incorporated into each
ZoneDefender as an additional safety feature.
Short circuit protection is also supplied, as
standard, for added peace of mind.
Installation is simple - the NEMA 4X
enclosure of ZoneDefender devices can be
easily ‘wall mounted’. Alternatively,
ZoneDefender units may be flush mounted by
way of an optional mounting plate which
should be specified at time of order
placement.
The ZoneDefender Series is UL 1449 2nd
Edition Listed and boasts an unrivalled 10
year ‘no questions asked’ manufacturers
product warranty. Zone-Defender devices
also exceed the requirements of
ANSI/IEEE C62.45 and
ANSI/IEEE C62.41.
ZoneDefender offers an LED Status
indication facility allowing each varistor
network to be continually monitored and
indicated by LEDs on the front panel of
the device. In addition, remote
monitoring is enabled by the
units’
remote
indication
contacts.
AC & DC Power
Protection
Specification
All figures typical at 77°F (25°C) unless otherwise stated
Model
Maximum surge current
80kA (8/20µs)*
*except ZoneDefender DC versions.
See specifications table for details.
Lines protected AC
L-N, L-G, L-L, N-G
Lines protected DC
V+, VAmbient temperature limits
–40°F to +185°F (–40°C to +85°C) -working
Humidity
95% RH (non-condensing)
Enclosure
NEMA 1, 2, 3, 3R, 4, 4X, 12 and 13 (IP66)
Terminals
12 AWG (3mm2)
Mounting
Surface mount by 0.21” (5mm) diameter holes
or flush mount via mounting plate
(Optional at time of order)
Remote contacts
NC 250Vac, 5A rated
Indication
Green LED on
Protection present
Green LED off
Internal failure
Weight
Three phase units
3.6 lbs (1.64Kg)
Split phase units
2.0 lbs (0.91Kg)
Single phase units
1.9 lbs (0.86Kg)
Dimensions
Three phase units
5.3” x 5.3” x 2.3”
(134.5mm x 134.5mm x 58.4mm)
Split phase units & single phase units
4.5” x 2.9” x 2.5”
(114.3mm x 73.6mm x 63.5mm)
EMC compliance
BS EN 60950: 1992
BS EN 61000-6-2: 1999
AC versions
14400
14401
14402
14404
14406
14407
14408
14409
DC versions
14612
14624
14648
14712
14724
14748
14812
14824
14848
Working
voltage
(V)
UL1449
Listing
(V)
120
120/240 split*
120/208
277/480
480
220/380
240/415
220
400
400
400
700
1500
700
700
700
435
435
435
890
1600
790
890
790
730
730
730
1200
2100
1200
1200
1200
12V DC
24V DC
48V DC
12V DC
24V DC
48V DC
12V DC
24V DC
48V DC
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
120
140
280
120
140
280
120
140
280
292
340
504
292
340
504
292
340
504
* Suitable for US use only
Let-through voltage
@ 3kA
@ 10kA
(V)
(V)
Max. continuous
operating voltage
(Vac)
140
140
140
320
550
275
320
275
Max. surge current
15kA
36kA
53kA
15kA
36kA
53kA
15kA
36kA
53kA
Phase types
Single phase 2-wire
Split phase 3-wire
Three phase 4-wire WYE
Three phase 4-wire WYE
Three phase 3-wire Delta
Three phase 4-wire WYE
Three phase 4-wire WYE
Single phase 2-wire
------------EMI filter
EMI filter
EMI filter
EMI filter & remote LED
EMI filter & remote LED
EMI filter & remote LED
8/20µs waveform - Tested as per ANSI/IEEE C62.45 and ANSI/IEEE C62.41
AC three phase connection
AC single phase connection
Figure 1 AC connection details
To order specify As per table above.
Note: In accordance with our policy of continuous improvement, we
reserve the right to change the product’s specification without
notice.
DC connections
Figure 2 DC connection details
Approvals
A member of the MTL Instruments Group plc
Standard/Authority
Approved for
Product
United States
Canada
UL 1449 2nd Edition Listed
AC power product
14400, 14401, 14402, 14404,
(C-UL US Listed)
14406, 14407, 14408, 14409
Rev D 02/05/04
Atlantic Scientific Corporation
4300 Fortune Place, Suite A W. Melbourne, FL 32904 USA
Tel: +1 800-544-4737, +1 321-725-8000 Fax: +1 321-727-0736
E-mail: sales@atlanticscientific.com, Web: www.atlanticscientific.com