ZoneMaster Up to 300kA power surge protection for total facility protection G Full protection redundancy plus thermal and short circuit fusing G LED status indication and optional remote monitoring unit with audio and visual indication G Optional high performance power filter and optional fuse disconnect G Silicon Avalanche Diode protection versions G Patented technology, UL 1449 2nd Edition Listed - tested per ANSI/IEEE C62.45, IEC 61643-1 G 10 year product warranty The ZoneMaster Series of surge protection devices combines unparalleled power handling capability, application versatility, proven circuitry along with simple installation, features which make ZoneMaster units the ultimate power protection solution. With 300kA, 250kA or 150kA versions available (ZoneMaster 300, ZoneMaster 250 and ZoneMaster 150 respectively), and with configurations suitable for all International supply voltages, ZoneMaster is truly a versatile and flexible protection range. ZoneMaster devices are modular in construction, individual modules are bolted to a large surge return plate to minimize transient impedance. These color coded, replaceable modules, with a UL 94-5V rated plastic casing are supplied mounted within a durable NEMA 4X (IP66) rated enclosure. ZoneMaster units are easy to install via simple wall mounting, although flush mounting is also an option for ZoneMaster 150 models (11200-11208). Large block, 3 terminal Metal Oxide Varistor (MOV) protection technology is utilized within the ZoneMaster range. ZoneMaster 300 and 250 versions include four totally redundant independent stages of protection per phase while the dual protection circuits of ZoneMaster 150 devices provide full redundancy ensuring the site is never unprotected. All ZoneMaster units also include thermal and short circuit fusing for additional safety while an integral fused disconnect feature is an optional extra. For even greater levels of protection, Silicon Avalanche Diode (SAD) versions are available incorporating both SAD and MOV technology. This SAD option allows for a lower let-through voltage, the worst case voltage that will get through to the protected equipment. LED status indication supplied as standard, normally open/ normally closed contacts change state to indicate a fault. An optional remote monitoring unit is also available providing audio and visual indication of protector status, along with features such as a test switch for checking the monitoring circuitry and an audio alarm silence switch. The optional power filter has a noise attenuation of 75dB at 100KHz- 100MHz and will attenuate 6kV transients down to just 200V. This power filter is UL 1283 Listed (with MOV ZoneMaster versions), and all ZoneMaster devices have UL 1449 Listing. is AC Power Protection Specification All figures typical at 77°F (25°C) unless otherwise stated Impulse current for class I (Im max) ZoneMaster 300 & 250 15kA ZoneMaster 150 10kA Maximum continuous operating voltage 25% above nominal Lines protected ZoneMaster 300 L-N 300kA, L-L 300kA, N-G 75kA ZoneMaster 250 L-N 250kA, L-L 250kA, N-G 75kA ZoneMaster 150 L-N 150kA, L-L 150kA, N-G 75kA Duty cycle performance (8/20μs) ZoneMaster 250 ZoneMaster 300 200,000A >2 impulses >4 impulses 10,000A >11,000 Impulses >12,000 impulses 200A infinite infinite ZoneMaster 150 100,000A >4 impulses 10,000A >8,000 impulses 150A infinite Long duration current pulse (10/1,000 μs) capability ZoneMaster 300 5,500A (tested) ZoneMaster 250 5,000A (tested) ZoneMaster 150 3,600A (tested) ZoneMaster 150 SAD/MOV SAD surge capacity: 12kA 8/20μs per phase Ambient temperature limits –40°F to +185°F (–40°C to +85°C) - working Humidity 95% RH (non-condensing) Enclosure NEMA 1, 2, 3, 3S, 4, 4X, 12 and 13 (IP66) Terminals 2 AWG (32mm2) Mounting Surface mount by 0.31” (8mm) diameter holes LED indication Green LED on Protection present* Mechanical flag Fault warning Red LED on High voltage neutral to ground Note: mechanical flag is fuse link operated *Excluding 3 wire delta models Remote contacts NO/NC 125Vac, 2A rated Weight ZoneMaster 300 & 250 - 12 lbs (5.5Kg) ZoneMaster 150 - 7 lbs (3.2Kg) EMC compliance BS EN 60950: 1992, BS EN 61000-6-2: 1999 Model Maximum surge current max (kA) Im ZoneMaster 300 17100 17101 17102 17103 17104 17106 17107 17108 ZoneMaster 300 SAD/MOV models 17110 (SMM) 17112 (SMMN) ZoneMaster 250 17000 17001 17002 17003 17004 17006 17007 17008 ZoneMaster 150 11200 11201 11202 11203 11204 11206 11207 11208 ZoneMaster 150 SAD/MOV models 11213 (SM)* 17113 (SM) 17117 (SM) 17121 (SMN) 17124(SM) 17111 (SSM) 17114 (SMN) 17115 (SMN) 17116 (SMN) 17122 (SM) 91046 (SMN) Working voltage (V) UL1449 Listing (V) Let-through voltage @3kA @10kA (In n) (V) (V) Phase types 300 300 300 300 300 300 300 300 120/240 split 120/208 120/240 240 277/480 480 220/380 240/415 330 330 330/700 700 700 1500 700 700 333 333 333 726 726 1480 726 726 406 406 406 826 826 1680 826 826 Split phase 3 wire Three phase 4 wire WYE Three phase 4 wire Delta Three phase 3 wire Delta Three phase 4 wire WYE Three phase 3 wire Delta Three phase 4 wire WYE Three phase 4 wire WYE 300 300 120/240 split 120/240 split 330 330 310 310 356 356 Split phase 3 wire Split phase 3 wire 250 250 250 250 250 250 250 250 120/240 split 120/208 120/240 240 277/480 480 220/380 240/415 330 330 330/700 700 700 1500 700 700 333 333 333 726 726 1480 726 726 406 406 406 826 826 1680 826 826 Split phase 3 wire Three phase 4 wire WYE Three phase 4 wire Delta Three phase 3 wire Delta Three phase 4 wire WYE Three phase 3 Wire Delta Three phase 4 wire WYE Three phase 4 wire WYE 150 150 150 150 150 150 150 150 120/240 split 120/208 120/240 240 277/480 480 220/380 240/415 400 400 400/800 800 800 1500 800 800 350 350 350 760 760 1480 760 760 446 446 446 886 886 1680 886 886 Split phase 3 wire Three phase 4 wire WYE Three phase 4 wire Delta Three phase 3 wire Delta Three phase 4 wire WYE Three phase 3 wire Delta Three phase 4 wire WYE Three phase 4 wire WYE 150 150 150 150 150 150 150 150 150 150 150 120/240 split 120/208 220/380 277/480 277/480 120/240 split 120/240 split 120/208 220/380 120/240 HL 240 330 330 700 700 700 330 330 330 600 700 N/A 312 312 540 600 600 290 312 312 540 312/540 540 356 356 730 820 820 356 356 356 730 356/730 730 Split phase 3 wire Three phase 4 wire WYE Three phase 4 wire WYE Three phase 4 wire WYE Three phase 4 wire WYE Split phase 3 wire Split phase 3 wire Three Phase 4 wire WYE Three phase 4 wire WYE Three phase 4 wire Delta Single phase Tested as per ANSI/IEEE C62.45; IEC 61643-1 Uoc = 6kV *Intregal Fused disconnect available KEY: SAD/MOV models S = SAD (Silicon Avalanche Diode), M = MOV (Metal Oxide Varistor), N = Neutral module e.g. Model number 17111 (SSM) has 2 x SADs per phase and 1 x MOV per phase. Model number 17116 (SMN) has 1 SAD per phase, 1 MOV per phase and 1Neutral module. Model number 17112 (SMMN) has 1 SAD per phase, 2 MOVs per phase and 1 Neutral module. Power filter Maximum continuous operating voltage 400Vac rated (L-N) Let-through voltage 200V (@ 3kA 8/20μs) Maximum attenuation (typical) -75dB (100kHZ to 100MHz) To order specify - Note: In accordance with our policy of continuous improvement, we reserve the right to change the product’s specification without notice. Atlantic Scientific Corporation 4300 Fortune Place, Suite A W. Melbourne, FL 32904 USA Tel: +1 800-544-4737, +1 321-725-8000 Fax: +1 321-727-0736 E-mail: sales@atlanticscientific.com, WWW: www.atlanticscientific.com A member of the MTL Instruments Group plc ZoneMaster 150 ZoneMaster 250 & 300 Figure 1 Dimensions Approvals Country Standard/Authority Approved for Product United States Canada UL 1449 2nd Edition Listed (C-UL US Listed) AC power product ZoneMaster 300 units ZoneMaster 250 units ZoneMaster 150 units Rev D 10/25/04 Model number as per specification table Add suffix X for power filter Add suffix F for flush mount options (models 11200 - 11208) Add suffix D for fuse disconnect (models 11200, 11201, 11202, 11204, 11207, 11208, 11213 and 17114) Optional Remote Monitoring Unit (Model number 11000)