ZoneMaster - Mamut.net

advertisement
ZoneMaster
Up to 300kA power surge protection for total
facility protection
G
Full protection redundancy plus thermal and
short circuit fusing
G
LED status indication and optional remote
monitoring unit with audio and visual indication
G
Optional high performance power filter and
optional fuse disconnect
G
Silicon Avalanche Diode protection versions
G
Patented technology, UL 1449 2nd Edition
Listed - tested per ANSI/IEEE C62.45,
IEC 61643-1
G
10 year product warranty
The ZoneMaster Series of surge protection
devices combines unparalleled power
handling capability, application versatility,
proven circuitry along with simple
installation, features which make ZoneMaster units the ultimate power protection
solution. With 300kA, 250kA or 150kA
versions available (ZoneMaster 300,
ZoneMaster 250 and ZoneMaster 150
respectively), and with configurations
suitable for all International supply voltages,
ZoneMaster is truly a versatile and flexible
protection range.
ZoneMaster devices are modular in
construction, individual modules are bolted to
a large surge return plate to minimize
transient impedance. These color coded,
replaceable modules, with a UL 94-5V rated
plastic casing are supplied mounted within a
durable NEMA 4X (IP66) rated enclosure.
ZoneMaster units are easy to install via
simple wall mounting, although flush
mounting is also an option for ZoneMaster
150 models (11200-11208).
Large block, 3 terminal Metal Oxide Varistor
(MOV) protection technology is utilized within
the ZoneMaster range. ZoneMaster 300
and 250 versions include four totally
redundant independent stages of protection
per phase while the dual protection circuits
of ZoneMaster 150 devices provide full
redundancy ensuring the site is never
unprotected. All ZoneMaster units also
include thermal and short circuit fusing for
additional safety while an integral fused
disconnect feature is an optional extra.
For even greater levels of protection, Silicon
Avalanche Diode (SAD) versions are available
incorporating both SAD and MOV technology.
This SAD option allows for a lower let-through
voltage, the worst case voltage that will get
through to the protected equipment.
LED status indication
supplied as standard,
normally
open/
normally closed
contacts
change state to indicate a fault. An optional
remote monitoring unit is also available
providing audio and visual indication of
protector status, along with features such
as a test switch for checking the monitoring
circuitry and an audio alarm silence switch.
The optional power filter has a noise
attenuation of 75dB at 100KHz- 100MHz
and will attenuate 6kV transients down to
just 200V. This power filter is UL 1283
Listed (with MOV ZoneMaster versions), and
all ZoneMaster devices have UL 1449
Listing.
is
AC Power
Protection
Specification
All figures typical at 77°F (25°C) unless otherwise stated
Impulse current for class I (Im
max)
ZoneMaster 300 & 250
15kA
ZoneMaster 150
10kA
Maximum continuous operating voltage
25% above nominal
Lines protected
ZoneMaster 300
L-N 300kA, L-L 300kA, N-G 75kA
ZoneMaster 250
L-N 250kA, L-L 250kA, N-G 75kA
ZoneMaster 150
L-N 150kA, L-L 150kA, N-G 75kA
Duty cycle performance (8/20μs)
ZoneMaster 250 ZoneMaster 300
200,000A >2 impulses
>4 impulses
10,000A >11,000 Impulses >12,000 impulses
200A infinite
infinite
ZoneMaster 150
100,000A >4 impulses
10,000A >8,000 impulses
150A infinite
Long duration current pulse (10/1,000 μs) capability
ZoneMaster 300
5,500A (tested)
ZoneMaster 250
5,000A (tested)
ZoneMaster 150
3,600A (tested)
ZoneMaster 150 SAD/MOV
SAD surge capacity: 12kA 8/20μs per phase
Ambient temperature limits
–40°F to +185°F (–40°C to +85°C) - working
Humidity
95% RH (non-condensing)
Enclosure
NEMA 1, 2, 3, 3S, 4, 4X, 12 and 13 (IP66)
Terminals
2 AWG (32mm2)
Mounting
Surface mount by 0.31” (8mm) diameter holes
LED indication
Green LED on
Protection present*
Mechanical flag Fault warning
Red LED on
High voltage neutral to
ground
Note: mechanical flag is fuse link operated
*Excluding 3 wire delta models
Remote contacts
NO/NC 125Vac, 2A rated
Weight
ZoneMaster 300 & 250 - 12 lbs (5.5Kg)
ZoneMaster 150 - 7 lbs (3.2Kg)
EMC compliance
BS EN 60950: 1992, BS EN 61000-6-2: 1999
Model
Maximum
surge current
max (kA)
Im
ZoneMaster 300
17100
17101
17102
17103
17104
17106
17107
17108
ZoneMaster 300
SAD/MOV models
17110 (SMM)
17112 (SMMN)
ZoneMaster 250
17000
17001
17002
17003
17004
17006
17007
17008
ZoneMaster 150
11200
11201
11202
11203
11204
11206
11207
11208
ZoneMaster 150
SAD/MOV models
11213 (SM)*
17113 (SM)
17117 (SM)
17121 (SMN)
17124(SM)
17111 (SSM)
17114 (SMN)
17115 (SMN)
17116 (SMN)
17122 (SM)
91046 (SMN)
Working
voltage
(V)
UL1449
Listing
(V)
Let-through voltage
@3kA
@10kA (In
n)
(V)
(V)
Phase types
300
300
300
300
300
300
300
300
120/240 split
120/208
120/240
240
277/480
480
220/380
240/415
330
330
330/700
700
700
1500
700
700
333
333
333
726
726
1480
726
726
406
406
406
826
826
1680
826
826
Split phase 3 wire
Three phase 4 wire WYE
Three phase 4 wire Delta
Three phase 3 wire Delta
Three phase 4 wire WYE
Three phase 3 wire Delta
Three phase 4 wire WYE
Three phase 4 wire WYE
300
300
120/240 split
120/240 split
330
330
310
310
356
356
Split phase 3 wire
Split phase 3 wire
250
250
250
250
250
250
250
250
120/240 split
120/208
120/240
240
277/480
480
220/380
240/415
330
330
330/700
700
700
1500
700
700
333
333
333
726
726
1480
726
726
406
406
406
826
826
1680
826
826
Split phase 3 wire
Three phase 4 wire WYE
Three phase 4 wire Delta
Three phase 3 wire Delta
Three phase 4 wire WYE
Three phase 3 Wire Delta
Three phase 4 wire WYE
Three phase 4 wire WYE
150
150
150
150
150
150
150
150
120/240 split
120/208
120/240
240
277/480
480
220/380
240/415
400
400
400/800
800
800
1500
800
800
350
350
350
760
760
1480
760
760
446
446
446
886
886
1680
886
886
Split phase 3 wire
Three phase 4 wire WYE
Three phase 4 wire Delta
Three phase 3 wire Delta
Three phase 4 wire WYE
Three phase 3 wire Delta
Three phase 4 wire WYE
Three phase 4 wire WYE
150
150
150
150
150
150
150
150
150
150
150
120/240 split
120/208
220/380
277/480
277/480
120/240 split
120/240 split
120/208
220/380
120/240 HL
240
330
330
700
700
700
330
330
330
600
700
N/A
312
312
540
600
600
290
312
312
540
312/540
540
356
356
730
820
820
356
356
356
730
356/730
730
Split phase 3 wire
Three phase 4 wire WYE
Three phase 4 wire WYE
Three phase 4 wire WYE
Three phase 4 wire WYE
Split phase 3 wire
Split phase 3 wire
Three Phase 4 wire WYE
Three phase 4 wire WYE
Three phase 4 wire Delta
Single phase
Tested as per ANSI/IEEE C62.45; IEC 61643-1 Uoc = 6kV
*Intregal Fused disconnect available
KEY: SAD/MOV models
S = SAD (Silicon Avalanche Diode), M = MOV (Metal Oxide Varistor), N = Neutral module
e.g. Model number 17111 (SSM) has 2 x SADs per phase and 1 x MOV per phase. Model number 17116 (SMN) has 1 SAD per phase, 1 MOV
per phase and 1Neutral module. Model number 17112 (SMMN) has 1 SAD per phase, 2 MOVs per phase and 1 Neutral module.
Power filter
Maximum continuous operating voltage
400Vac rated (L-N)
Let-through voltage
200V (@ 3kA 8/20μs)
Maximum attenuation (typical)
-75dB (100kHZ to 100MHz)
To order specify -
Note: In accordance with our policy of continuous improvement, we
reserve the right to change the product’s specification without
notice.
Atlantic Scientific Corporation
4300 Fortune Place, Suite A W. Melbourne, FL 32904 USA
Tel: +1 800-544-4737, +1 321-725-8000 Fax: +1 321-727-0736
E-mail: sales@atlanticscientific.com, WWW: www.atlanticscientific.com
A member of the MTL Instruments Group plc
ZoneMaster 150
ZoneMaster 250 & 300
Figure 1 Dimensions
Approvals
Country
Standard/Authority
Approved for
Product
United States
Canada
UL 1449 2nd Edition
Listed
(C-UL US Listed)
AC power product
ZoneMaster 300 units
ZoneMaster 250 units
ZoneMaster 150 units
Rev D 10/25/04
Model number as per specification table
Add suffix X for power filter
Add suffix F for flush mount options
(models 11200 - 11208)
Add suffix D for fuse disconnect
(models 11200, 11201, 11202, 11204, 11207, 11208,
11213 and 17114)
Optional Remote Monitoring Unit