LV1_20.book Seite 1 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix 20/2 Glossary 20/6 Training 20/7 Ordering notes 20/10 Further documentation 20/11 Standards and approvals 20/29 Quality management 20/30 Siemens contacts 20/31 Online services 20/32 Customer support 20/33 Software licenses 20/34 Subject index 20/41 Order number index including export markings 20/71 Conditions of sale and delivery, export regulations Siemens LV 1 · 2008 LV1_20.book Seite 2 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Glossary ■ Requirements to be met by circuit breakers/motor starter protectors for motor protection NSK-5962 • Insensitivity to inrush current: - Response values of the short-circuit trip units up to 13 x In or - Inrush current bridging through tripping delay (approx. 10 ms to 20 ms) • Temperature compensation • Phase failure sensitivity • Adjustable trip class for adapting to the motor start-up characteristic • Thermal image memory (several start-up attempts raise the temperature of the motor) • Overload trip unit according to IEC 60947-4-1: - Must not trip at 1.05 times load within two hours - Must trip at 1.2 times load within two hours (at 1.15 times load for 2-phase load). Circuit breakers / motor starter protectors for motor protection Switching • Operational currents of motors • Short-circuit currents which arise in this load feeder If circuit breakers with adjustable time lag class are used, they can be adapted to practically any motor starting current. ■ Circuit breakers/motor starter protectors for starter combinations NSK-5963 These circuit breakers/motor starter protectors are designed only for short-circuit protection of the downstream devices and loads; they have no overload trip units. The short-circuit trip unit is adjustable. In this case the overload protection must be realized elsewhere. This can be a simple bimetal relay or a user-friendly electronic motor controller (SIMOCODE) between the load contactor and the load. As the result it is very easy in the event of a fault to distinguish between the overload relay (feedback of the bimetal relay) or the short-circuit trip unit (feedback of the circuit breaker/ motor starter protector). If a motor starter protector/circuit breaker with overload protection is selected, then a clear-cut assignment of the device feedback is not possible without additional steps. The correct assignment of contactors, overload relay and circuit breaker can be found in the publication "Load Feeders in Fuseless Designs", Order No. E20001-A580-P302-V2-7600 or in the corresponding tables in the Technical Information LV 1 T. 20 NSK-5964 ■ Non-automatic air circuit breakers 20/2 Siemens LV 1 · 2008 This form of circuit breaker is used wherever different load circuits have to be disconnected from or connected to each other. They are not equipped with overload trip units. The short-circuit trip unit is not adjustable. LV1_20.book Seite 3 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Glossary ■ Current-limiting circuit breakers This symbol indicates the flow of the short-circuit current downstream from the circuit breaker. Because the let-through current of the circuit breaker is smaller than the maximum value of the short-circuit current (dotted line), the term "current-limiting circuit breaker" is used. N S E 0 0 1 2 7 0 The load on the downstream devices, cables and conductors is greatly reduced as the result (in this connection see the current limiting characteristics). ■ Requirements to be met by circuit breakers for system protection NSE0_00695 • Compliance with the standards IEC 60947-1 and IEC 60947-2: - Must not trip at 1.05 times load within two hours - Must trip at 1.3 times load within two hours • Usual setting ranges: - Adjustability of the overload trip unit is usually not required - Response values of the short-circuit trip units 1.25 to 10 x In • Analysis of selectivity required Circuit breakers for system protection with permanently set values They have a permanently set overload trip unit and a permanently set short-circuit trip unit. Current limiting. Example: Outgoing feeder to sub-distribution boards/distribution boards. ■ Circuit breakers for system protection with some permanently set values They have a permanently set overload trip unit and an adjustable short-circuit trip unit. Current limiting. NSE0_00015 Example: Outgoing feeder to sub-distribution boards/distribution boards with special requirements to be met by the short-circuit trip unit. ■ Circuit breakers for system protection with adjustable values They have an adjustable overload trip unit and an adjustable short-circuit trip unit. Current limiting. Example: For direct protection of non-motor loads. 20 NSE0_00704 Siemens LV 1 · 2008 20/3 LV1_20.book Seite 4 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Glossary ■ Circuit breakers for system protection with adjustable values and a short-delayed trip unit This means that: • L: Inverse-time delayed overload trip unit or thermal overload trip unit. - If the actual current exceeds the value of the set operational current (Ir), then the circuit breaker will trip within a certain time. - The time of the tripping depends on the level of current. - The higher the level of current, the shorter the time up to tripping. • S: Short-time delayed short-circuit trip unit. - The level of the short-circuit current (Isd) is variably adjustable. - The trip system (electromagnetic or solid-state) is excited by the short-circuit current which flows through the circuit breaker. - Tripping is delayed for the set time (tsd). - Time-selective coordination of circuit breakers is thus possible. • I: Instantaneous short-circuit trip units. - The trip system (electromagnetic or solid-state) is excited by the short-circuit current which flows through the circuit breaker. - Tripping is instantaneous. L S I NSE0_00008 It makes sense for the value for the I trip unit (Ii) to be greater than the value for the S trip unit. If the time (tsd) is selected as zero for the S trip unit, then the S trip unit responds like the I trip unit, i.e. tripping is likewise instantaneous. Example: Fully selective circuit breaker in power distributions. ■ Circuit breakers/motor starter protectors for motor protection with permanently set time lag class They have an adjustable overload trip unit, a permanently set short-circuit trip unit and a permanently set time lag class. Current limiting. Example: For protecting motors with this start-up class. 20 NSE0_01243 20/4 Siemens LV 1 · 2008 LV1_20.book Seite 5 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Glossary ■ Circuit breakers/motor starter protectors for motor protection with adjustable time lag class They have an adjustable overload trip unit, a permanently set short-circuit trip unit and an adjustable time lag class. Current limiting. With phase failure sensitivity. NSE0_00706 Example: Protection of motors with different start-up classes (one standard circuit breaker/motor starter protector for all motors). ■ Circuit breakers/motor startet protectors for starter combinations They have an adjustable short-circuit trip unit but no overload trip unit. Current limiting. NSE0_00707 Example: Wherever a bimetal relay is connected downstream and a separate signal for short-circuit (from the starter circuit breaker) and overload (from the bimetal relay) is required. ■ Non-automatic air circuit breakers, current-limiting MCCB: They have a permanently set short-circuit trip unit but no overload trip unit (VL160X to VL1600). Let-through current is limited. NSE0_00708 Example: For disconnecting different load circuits. ■ Non-automatic air circuit breakers ACB: They have neither an overcurrent trip unit nor a short-circuit trip unit (3W.). Not current-limiting: Example: For disconnecting different load circuits. 20 N S E 0 _ 0 0 0 1 7 Siemens LV 1 · 2008 20/5 LV1_20.book Seite 6 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Training ■ Faster and more applicable know-how: Hands-on training from the manufacturer SITRAIN® – the Siemens Training for Automation and Industrial Solutions – provides you with comprehensive support in solving your tasks. Training by the market leader in automation and plant engineering enables you to make independent decisions with confidence. Especially where the optimum and efficient use of products and plants are concerned. You can eliminate deficiencies in existing plants, and exclude expensive faulty planning right from the beginning. ■ SITRAIN highlights Top trainers Our trainers are skilled teachers with direct practical experience. Course developers have close contact with product development, and directly pass on their knowledge to the trainers. Practical experience The practical experience of our trainers enables them to teach theory effectively. But since theory can be pretty drab, we attach great importance to practical exercises which can comprise up to half of of the course time. You can therefore immediately implement your new knowledge in practice. We train you on stateof-the-art methodically/didactically designed training equipment. This training approach will give you all the confidence you need. Wide variety With a total of about 300 local attendance courses, we train the complete range of A&D products as well as interaction of the products in systems. Telecourses, teach-yourself software and seminars with a presenter on the Web supplement our classic range of courses. Tailor-made training We are only a short distance away. You can find us at more than 50 locations in Germany, and in 62 countries worldwide. You wish to have individual training instead of one of our 300 courses? Our solution: We will provide a program tailored exactly to your personal requirements. Training can be carried out in our Training Centers or at your company. First-class know-how directly pays for itself: In shorter startup times, high-quality end products, faster troubleshooting and reduced downtimes. In other words, increased profits and lower costs. Achieve more with SITRAIN • Shorter times for startup, maintenance and servicing • Optimized production operations • Reliable configuration and startup • Minimization of plant downtimes • Flexible plant adaptation to market requirements • Compliance with quality standards in production • Increased employee satisfaction and motivation • Shorter familiarization times following changes in technology and staff ■ Contact Visit our site on the Internet at: www.siemens.com/sitrain or let us advise you personally. You can request our latest training catalog from: SITRAIN Customer Support Germany: Phone:+49 (0)1805 / 23 56 11 (0.14 €/min from the German landline network) +49 (0)1805 / 23 56 12 20 Fax: 20/6 Siemens LV 1 · 2008 The right mixture: Blended learning "Blended learning" means a combination of various training media and sequences. For example, a local attendance course in a Training Center can be optimally supplemented by a teachyourself program as preparation or follow-up. Additional effect: Reduced traveling costs and periods of absence. LV1_20.book Seite 7 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Ordering notes ■ Logistics General Packaging, packing units With regard to delivery service, communications and environmental protection, our logistics service ensures "quality from the moment of ordering right through to delivery". By designing our infrastructure according to customer requirements and implementing electronic order processing, we have successfully optimized our logistics processes. The packaging in which our equipment is dispatched provides protection against dust and mechanical damage during transport, thus ensuring that you receive our products in a perfect state. To achieve this, we supply } the preferred types marked with ex warehouse. We regard the DIN ISO 9001 certification and consistent quality checks as an integral part of our services. Electronic order processing is fast, cost-efficient and error-free. Please contact us if you want to benefit from these advantages. With our multi-unit packaging and reusable packaging, we offer you specific types of packaging that are both kind to the environment and tailored to your requirements: Your advantages at a glance: • Lower order costs. • Cost savings through uniform-type packaging: low/no disposal costs. • Reduced time and cost thanks to short unpacking times. • "Just-in-time" delivery directly to the production line helps reduce stock: cost savings through reduction of storage area. cost savings through reduction of storage area. • Fast assembly thanks to supply in sets. • Standard Euro boxes - corresponding to the Euro pallet modular system - suitable for most conveyor systems. • Active contribution to environmental protection. Unless stated otherwise in the "Selection and ordering data" of this catalog, our products are supplied individually packed. For small parts/accessories, we offer you economical packaging units as standard packs containing more than one item, e.g. 5, 10, 50 or 100 units. It is essential that whole number multiples of these quantities be ordered to ensure satisfactory quality of the products and problem-free order processing. The products are delivered in a neutral carton. The label includes warning notices, the CE mark, the open arrow recycling symbol, and product description information in English and German. In addition to the Order No. (MLFB) and the number of items in the packaging, the Instr. Order No. is also specified for the operating instructions. It can be obtained from your local Siemens representative (you will find a list of your local Siemens representatives at http://www.siemens.com/lowvoltage/ support). The device Order No. of most devices can also be acquired through the EAN barcode to simplify ordering and storage logistics. The Order Nos. are assigned electronically to the EAN code in the master data of low-voltage controls. 20 We are proud of our personal consulting service, on-time deliveries and 1-day transport within Germany. We select our packaging for maximum environmental compatibility and reusability (e.g. crumpled paper instead of polystyrene chips for protection during transport in packages up to 32 kg) and, in particular, with a view to reducing waste. Siemens LV 1 · 2008 20/7 LV1_20.book Seite 8 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Ordering notes Multi-unit and reusable packagings Multi-unit packaging The devices listed in the table on Page 20/9 can be ordered in multi-unit or reusable packagings (further versions on request). If ordering multi-unit or reusable packagings for the first time, please first consult your local Siemens representative with regard to packaging type, quantity, delivery time and the precise order designation. For transport reasons, the use of reusable packaging is recommended only for EU countries. For both pack types, the quantity of devices ordered (per Order No.) must be divisible by the packaging quantity. If this is not the case, the electronic order processing system rounds up to the next integer multiple of packagings. Products in a quantity sufficient to fill a multi-unit packaging: 1/2 (W96) and 1/4 (W97) ENK As standard, multi-unit packs contain uniform-type, unpacked individual products (1 device type) in an appropriately sized carton made of recyclable cardboard. The products of the SIRIUS range can be ordered in units of 1/1, 1/2, 1/4 and 1/8 standard Euro boxes (ENK). When ordering products in multi-unit packagings, the Order No. of the product concerned must be supplemented with "–Z" and, in addition, the order code X90, or for products from the SIRIUS range, the order code W9.. Example: 3RT10 24–1AB00–Z W96 + quantity: 48 Reusable packaging (uniform type) Standard reusable packagings contain uniform-type, nonpacked individual products (1 device type) in a reusable standard Euro box (ENK) made of durable molded plastic with foam inserts for protection during transport. The standard Euro box (ENK) also serves as transport packaging. The reusable packagings (ENK) plus foam inserts are returned by the customer (free of charge) to the supply base. For products packed in reusable packaging, the Order No. must be supplemented with "–Z" and the order code X95. 20 Example: 3RT10 24–1AB00–Z X95 + quantity: 96 20/8 Siemens LV 1 · 2008 LV1_20.book Seite 9 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Ordering notes Set deliveries (reusable, different devices) Packaging dimensions On request, we also deliver order-related packs of larger quantities of different unpacked devices in standard Euro boxes. Packaging Please contact your Siemens representative (you will find Siemens representatives at http://www.siemens.com/ automation/partner) to clarify the delivery details or conditions for set supply or delivery in reusable packagings. Suitable arrangements will then be agreed with you. Length Height Width mm mm mm ENK 598 220 396 W95 W96 W97 W98 576 380 290 290 192 187 187 98 380 290 190 190 Multi-unit and reusable packaging, quantity in units, supplied in indivisible packaging quantities Reusable Multi-unit X95 (1/1 ENK) W95 (1/1 ENK) 144 96 52 66 30 27 24 144 96 52 66 30 27 24 90 48 24 35 15 15 15 42 24 12 17 – – – 20 12 6 10 – – – 600 600 280 140 70 144 144 90 42 20 96 61 24 96 61 24 48 29 12 24 14 – 12 – – 128 88 36 128 88 36 64 45 18 32 22 – 16 14 – 52 52 52 52 26 26 12 12 6 6 Solid-state timing relays: 3RP15 05–...30, 3RP15 60–.S.30 3RP15 1/2/4/5.–.A.30 3RP15 2/4.–.B.30 3RP15 3.–.A.30 3RP15 74 –.N.30 137 192 137 137 192 137 192 137 137 192 67 96 67 67 96 27 48 27 27 48 16 24 16 16 24 Devices Reusable Multi-unit X95 X90 – – – – – 50 20 150 100 50 Contactors, sizes S00 ... S2 3RT10 1.–.A/B..1/2 3RT10 2.–.A..0 3RT10 2.–.A.. 4 3RT10 2.–.B..0 3RT10 3.–.A..0/4 3RT10 3.–.B..0 3RT10 3.–.B..4 Snap-on auxiliary switch blocks Size S00: 3RH19 11–1F./GA/HA.. Contactor relays, size S00 3RH11 ..–.A/B..0 Motor starter protectors, sizes S00 ... S2: 3RV10 11–....0 3RV10 21–....0 3RV10 31–....0 Thermally delayed overload relays Sizes S00 ... S2: 3RU11 16–..B0 3RU11 26–..B0 3RU11 36–..B0 Fuseless load feeders up to 12 A, size S00: 3RA11 10–..A..–1AP0 3RA11 10–..A..–1BB4 3SB pushbutton units and indicator lights Complete units and actuators (except EMERGENCY-STOP and key-operated switches) Complete units and actuators (EMERGENCY-STOP and keyoperated switches) Contact blocks Holders Supports, blanking plugs Safety relays 3TK28, 3TK29 23 ■ Orders for special versions For ordering products that differ from the versions listed in the catalog, the order number specified in the catalog must be supplemented with "–Z"; the required features must be specified by means of the alphanumeric order codes or in plain text. W96 (1/2 ENK) W97 (1/4 ENK) W98 (1/8 ENK) – ■ Small orders When small orders are placed, the costs associated with order processing are greater than the order value. We recommend therefore that you combine several small orders. Where this is not possible, we unfortunately have to charge a processing supplement of € 20.-- to cover our costs for order processing and invoicing for all orders with a net goods value of less than € 250.--. Siemens LV 1 · 2008 20/9 20 Devices LV1_20.book Seite 10 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Further documentation ■ Overview You will find all the latest information material, such as brochures, catalogs, manuals and operating instructions on lowvoltage controls and distribution on the Internet at: http://www.siemens.com/lowvoltage/info Here you can order your copy of the available documentation or download it in common file formats (PDF, ZIP). We regard product support as just as important as the products and systems themselves. Visit our Support site on the Internet for a comprehensive range of material on SIRIUS, SENTRON and SIVACON, such as • Catalogs available to order free of charge • Operating instructions and manuals for direct download • Online registration for seminars and events • Up-to-date answers to your queries and problems • Software upgrades and updates for fast download • Telephone assistance in more than 190 countries • Photos and graphics for external use and much, much more - all conveniently and easily accessible. For your inventory control and planning systems we can provide commercial, technical and graphic data in electronic form for the range of low-voltage control products: Master Data of Low-Voltage Controls V2.0 Edition 2008 The CD-ROM contains commercial master data for low-voltage control products for further processing in inventory control and planning systems in the formats DATANORM, ELDANORM, CSV, ASCII, DBASE, XML and MS ACCESS97. We also provide further support for SIRIUS - SENTRON - SIVACON Order No.: E86060-D1003-A301-A6 Token fee 5.-- € Technical Product Data for CAx Applications Edition 04/2007 The DVD provides technical and graphic data for the range of low-voltage control products for further processing in CAE/CAD systems. The technical data are available in ASCII, in the format of ECAD Component Standard V1.2, and in other system-specific formats. Graphic data are provided in DXF and DWG format. Order No.: E86060-D1000-A207-A5-6300 Token fee 48.-- € Technical Product-Data Collection Edition 04/2007 Brochures, catalogs and CDs offer fast and more in-depth information For the low-voltage control products the two DVDs contain 2D dimensional drawings in DXF format, 3D models in STEP format and product data sheets as PDF files in 4 languages (German, English, French, Spanish). Texts for tenders are available in GAEB and Text format. Order No.: E86060-D1004-A101-A3-7400 20 Token fee 10.-- € 20/10 Siemens LV 1 · 2008 LV1_20.book Seite 11 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals ■ Overview Approvals, test certificates, characteristic curves Safety characteristics An overview of the certificates available for low-voltage control products along with more technical documentation can be consulted daily on the Internet at: In the following standards, the so-called B10 values for calculating the safety integrity or safety integrity level (SIL) in functional safety at a high or continuous demand rate are required also for electromechanical switchgear: • IEC 62061 "Safety of machines - Functional safety of safety-related electrical, electronic and programmable electronic control systems", • ISO 13849-1:2006 "Safety of machines - Safety-related components of controls - Part 1: General principles". http://www.siemens.com/lowvoltage/support Failure rates of electromechanical components are required for calculating the safety integrity or safety integrity level (SIL) in functional safety at a low rate of demand. Further requirements are laid down in IEC 61511-1 "Functional safety - Safety instrumented systems for the process industry sector - Part 1: Framework, definitions, system, hardware and software requirements". The German versions of the above standards are: • EN 62061 (VDE 0113-50), October 2005, which since 31.12.2005 has been harmonized as EN 62061 under the Machine Directive, • EN ISO 13849-1:2006, • EN 61511-1 (VDE 810-1). Definitions Product support: Certificates λ(t) dt is the probability that a unit which has not failed by a certain time t will fail in the following interval (t; t +dt). Failure rates have the dimension 1/time unit, e.g. 1/h. Failure rates for components are often specified in FIT (failures in time unit): 1 FIT equals 10-9/h. From the failure rate it is possible to derive a (mathematical) distribution function of the failure probability: F(t) = 1 - exp(-λt), with λ as constant failure rate • The mean value of this exponential distribution is also referred to as: - Mean Time To Failure (MTTF) in the case of irreparable components; 63.2 % of components fail by the MTTF. - Mean Operating Time Between Failures (MTBF) in the case of reparable components. • MTTF = 1/λ (MTTF is a statistical mean value but no guarantee for endurance) Electromechanical components are often irreparable components. In general, the failure rate of monitored units changes with age. The B10 value for devices subject to wear is expressed in number of operating cycles: • it is the number of operating cycles after which 10 % of the test specimens fail in the course of an endurance test (or: the number of operating cycles after which 10 % of the devices have failed). For low demand rates (mainly in the process industry), the failure rate and not the B10 value is used to determine the failure probability. 20 Product support: Characteristic curves Siemens LV 1 · 2008 20/11 LV1_20.book Seite 12 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals Standard B10 values at a high demand rate Standard failure rates (at a low demand rate) With the help of the B10 value and a simplified formula (see section 6.7.8.2.1 of EN 62061), the user can then calculate the total failure rate of an electromechanical component: On the basis of the failure rates it is possible to calculate the average probability of failure on demand (PFDavg) of a PLT protective device. λ = 0.1 x C / B10 A so-called low demand rate is assumed, meaning the rate of demand on the safety-related system amounts to no more than once a year and is not greater than double the frequency of the repeat test. with C = operating cycles per hour. C is specified by the user. The failure rate is made up of safe (λS) and dangerous (λD) failures: λ = λS+ λD A repeat test once a year is recommended for electromechanical components in order to reveal passive faults. For special applications it is possible, in agreement with the inspecting institution (e.g. a technical inspectorate, government agency or the like) to extend the test intervals by using suitable solutions (e.g. a mutli-channel version etc.). or λD = [share of dangerous failures in %] x λ λS = [share of safe failures in %] x λ The failure rate of the dangerous failures λD of the components used is needed for further calculations. Listed in the following table are the standard B10 values and the share of dangerous failures for SIRIUS product groups at a high demand rate. Under the above conditions and in compliance with the requirements laid down in IEC 61511 it is possible to achieve SIL 2 with a single-channel design and SIL 3 with a two-channel design. Listed in the following table are the standard failure rates and the share of dangerous failures for SIRIUS product groups at a low demand rate. Standard B10 values (at a high demand rate) Standard failure rates at a low demand rate SIRIUS product group (electromechanical components) Standard B10 value (operating cycles) Share of dangerous failures (electromechanical components) EMERGENCY-STOP control devices (with positive-opening contacts) - rotate-to-unlatch - pull-to-unlatch Cable-operated switches for EMERGENCY-STOP function (with positive-opening contacts) SIRIUS product group 100 0001) 30 0001) 20 % 20 % 1 000 0001) 20 % Standard failure rates (in FIT)1) Share of dangerous failures2) EMERGENCY-STOP control devices (with positive-opening contacts) 1003) 20 % Cable-operated switches for EMERGENCY-STOP function (with positive-opening contacts) 1003) 20 % Standard position switches (with positive-opening contacts) 100 20 % 10 000 0002) 20 % Position switches with separate actuator (with positive-opening contacts) 100 20 % Position switches with separate actuator (with positive-opening contacts) 1 000 0001) 20 % Position switches with tumbler (with positive-opening contacts) 100 20 % Position switches with tumbler (with positive-opening contacts) 1 000 0001) 20 % Hinge switches (with positive-opening contacts) 100 20 % Hinge switches (with positive-opening contacts) 1 000 0001) 20 % Pushbuttons (non-latching) (with positive-opening contacts) 100 20 % Pushbuttons (non-latching) (with positive-opening contacts) 10 000 0002) 20 % Contactors / motor starters (with positive-opening contacts or mirror contacts) 100 < 40 %4) Standard position switches (with positive-opening contacts) Contactors / motor starters (with positive-opening contacts or mirror contacts) 1 000 0002) 75 %3) 1) The failure rates specified in the table were limited to 100 FIT. 2) Valid only under the previously mentioned conditions. 1) Limited primarily by mechanical wear. 3) 2) Limited likewise to 100 FIT due to overruling protection with latching. Limited primarily by contact wear. 4) 3) Through fault detection using positive-opening auxiliary switches it is possible to improve the SIL level. Through fault detection using positive-opening auxiliary switches it is possible to improve the SIL level. The B10d value used in EN ISO 13849-1:2006 is determined as follows: B10d = B10 Share of dangerous failures Calculation example A protective door is monitored by a position switch with a separate actuator. The protective door is opened 4 times an hour. The overall failure rate of the position switch is: λ = 0.1 · C / B10 [failures / h] λ = 0.1 · 4 / 1 000 000 = 4 · 10-7 [failures / h] The dangerous failure rate is calculated with: 20 λD = 20 % of λ = 0.2 · 4 · 10-7 [failures / h] λD = 8 · 10-8 [failures / h] 20/12 Siemens LV 1 · 2008 LV1_20.book Seite 13 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals Standards IEC EN DIN VDE Title 60947-1 60947-2 60947-3 60947-1 60947-2 60947-3 ---- Low-voltage controlgear and switchgear: General requirements • Motor starter protectors • Load-break switches, disconnectors, switch disconnectors and fuse-combination units 60947-4-1 60947-4-2 60947-4-3 60947-4-1 60947-4-2 60947-4-3 ---- • Contactors and motor starters: Electromechanical contactors and motor starters • Contactors and motor starters: Semiconductor motor controllers and starters, soft starters • AC semiconductor controllers and contactors for loads other than motors 60947-5-1 60947-5-2 60947-5-3 60947-5-5 60947-5-6 60947-5-1 60947-5-2 60947-5-3 60947-5-5 60947-5-6 ------ • • • • • 60947-5-7 60947-5-8 60947-5-9 60947-5-7 60947-5-8 60947-5-9 ---- Control devices and switching elements: Electromechanical control devices Control devices and switching elements: Proximity switches Proximity switches (specific behavior under fault conditions) EMERGENCY-STOP devices with mechanical latching Control devices and switching elements - DC interface for proximity switches and switching amplifier (NAMUR) • Requirements for proximity switches with analog output • Approval switches • Flow sensors 60947-6-1 60947-6-2 60947-6-1 60947-6-2 --- • Multifunctional controlgear and switchgear: Transfer switches • Multifunctional controlgear and switchgear: Control and protection switchgear (CPS) 60947-7-1 60947-7-2 60947-7-3 60947-7-1 60947-7-2 60947-7-3 ---- • Ancillary equipment: Terminal blocks for copper conductors • Ancillary equipment: PE conductor terminal blocks for copper conductors • Ancillary equipment: Safety requirements for terminal blocks 60947-8 60947-8 -- • Tripping units for the integrated thermal Protection (PTC) of rotating electric machines 62026-2 50295 -- • Actuator-Sensor Interface (AS-i) 60269-1 60269-4 60269-1 60269-4 --- Low-voltage fuses: General requirements Low-voltage fuses: Supplementary requirements for fuse links for protecting semiconductor components 60050-441 -- -- International dictionary / switchgear and / or switching devices and fuses 60439-1 -- 60439-1 50274 --- 61140 61140 -- Low-voltage switchgear and controlgear combinations: Type-tested and partially type-tested assemblies Low-voltage switchgear and controlgear combinations: - Protection from electric shock - Protection from accidental touching of dangerous active parts Protection from electric shock - General requirements for apparatus and equipment 60664-1 60664-1 -- Insulation coordination for electrical equipment in low-voltage systems; Principles, requirements and tests 60204-1 -60079-14 60204-1 50178 60079-14 ---- 60079-2 60079-2 -- Electrical equipment of machines: General requirements Equipment of electrical power installations with electronic equipment Electrical apparatus for potentially explosive gas atmospheres Installing electrical apparatus in potentially explosive gas atmospheres (except mining) Electrical equipment for potentially explosive gas atmospheres - Part 2 Pressurized enclosures "p" 61810-1 61810-1 -- 61812-1 61812-1 -- 60999-1 60999-1 -- 61558-1 61558-1 -- Safety of transformers, power supply units and similar: 61558-2-1 61558-2-2 61558-2-1 61558-2-2 --- 61558-2-4 61558-2-6 61558-2-20 61558-2-4 61558-2-6 61558-2-20 ---- Particular requirements for mains transformers for general use Safety of transformers, power supply units and similar - Part 2-2: Particular requirements for control transformers Particular requirements for isolating transformers for general use Particular requirements for safety transformers for general use Particular requirements for small reactors 60076-11 -- 60076-11 -- -0552 Power transformers - Part 11: Dry transformers Standards for variable-ratio transformers with moving contacts perpendicular to the coiling direction 61000-4-1 61000-4-1 -- 61000-6-3 61000-6-3 -- 61000-6-4 61000-6-4 -- Electromagnetic compatibility (EMC) - Part 4: Testing and measuring techniques; Main Section 1: Overview of measuring techniques for interference immunity; Basic EMC standard Electromagnetic compatibility (EMC); Basic specification for emitted interference in residential and commercial environments as well as in light industry Electromagnetic compatibility (EMC); Basic specification for emitted interference in industrial environments 60044-1 60044-1 -- Instrument transformers: Current transformers JIS Title UL CSA C22.2 ASME Electromechanical elementary relays (electromechanical switching relays without a fixed time response); General and safety-related requirements Relays with a fixed time response (timing relays) for industrial applications Part 1: Requirements and tests Connecting materials - Safety requirements for screw terminals and screwless clamping points for electrical copper conductors - Part 1: General requirements and special requirements for terminals for conductors from 0.2 mm2 to 35 mm2 506 508 489 1012 Specialty transformers Industrial control equipment Molded case circuit breakers, molded case switches, and circuit breaker enclosures Power units other than CLASS 2 1561 1604 Dry-type general purpose and power transformers Electrical equipment for potentially explosive (classified) atmospheres of classes I and II, category 2, and class III Terminal blocks Wire connectors 1059 486A-486B 486E Internal wiring points for aluminum and / or copper conductors Specialty transformers Industrial control equipment Molded case circuit breakers, molded case switches, and circuit breaker enclosures General use power supplies A17.5 / B 44.1 Elevator and escalator electrical equipment 20 No. 66 No. 14 No. 5 No. 107 C 8201-4-1 Low-voltage switchgear and controlgear; Contactors and motor-starters Siemens LV 1 · 2008 20/13 LV1_20.book Seite 14 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals ■ Approval requirements valid in different countries Siemens low-voltage switchgear and controlgear are designed, manufactured and tested according to the relevant German standards (DIN and VDE), IEC publications and European standards (EN) as well as CSA and UL standards. The standards assigned to the single devices are stated in the relevant parts of this catalog. As far as is economically viable, the requirements of the various regulations valid in other countries are also taken into account in the design of the equipment. In some countries (see table below), an approval is required for certain low-voltage switchgear and controlgear components. Depending on the market requirements, these components have been submitted for approval to the authorized testing institutes. In some cases, CSA for Canada and UL for the USA only approve special switchgear designs. Such special versions are listed separately from the standard versions in the individual parts of this catalog. For this equipment, partial limitations of the maximum permissible voltages, currents and ratings can be imposed, or special approval and, in some cases, special identification is required. For use on board ship, the specifications of the marine classification societies must be observed (see table below). In some cases, they require type tests of the components to be approved. The present state of approval is shown in the "Overview of approved equipment" tables on Page 20/18 to Page 20/26. ■ Testing bodies, approval identification and approval requirements Country Canada 1) USA 1) China Government-appointed or private, officially recognized testing bodies CSA UL (USA) UL CQC Approval symbol s u Approval requirements + Remarks UL and CSA are authorized to grant approvals according to Canadian CCC or US regulations. Please note: these approvals are frequently not recognized and additional approval often has to be obtained from the national testing authority. c u cU c UUS U c UUS + For more information about UL and CSA see Page 20/17. 1) + For guide numbers and file numbers for approvals, please visit http://www.siemens.com/automation/support and select "Product Support". ■ Marine classification societies Germany United Kingdom France Norway CIS Italy Poland USA Name Germanischer Lloyd Lloyds Register of Shipping Bureau Veritas Det Norske Veritas Russian Maritime Register of Shipping Registro Italiano Navale Polski Rejestre Statków American Bureau of Shipping Codes GL LRS BV DNV RMRS RINA PRS ABS 20 Country 20/14 Siemens LV 1 · 2008 LV1_20.book Seite 15 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals ■ CE mark of conformity Manufacturers of products which fall within the subject area to which EC directives apply must identify their products, instruction manuals or packaging with a CE mark of conformity. The CE mark of conformity confirms that a product fulfills the appropriate basic requirements of all pertinent directives. The mark of conformity is a mandatory requirement for putting products into circulation throughout the EC. All the products in this catalog are in conformance with the EC directives and bear the CE mark of conformity. • Low-voltage directive • EMC directive • Machinery directive • Ex protection directive The CE mark of conformity: >. ■ ALPHA/LOVAG The Low-Voltage Controls and Distribution Division of Siemens AG is a member of the "Gesellschaft zur Prüfung und Zertifizierung von Niederspannungsgeräten e.V. ALPHA" (Society for Testing and Certification of Low-Voltage Equipment), Frankfurt am Main. The responsibility of manufacturers and the high quality of products are promoted by ALPHA by means of supportive procedural guidelines for testing equipment according to the currently valid standards. List of LOVAG members ALPHA ASEFA ACAE SGS CEBEC Intertek Semko AB APPLUSS + CTC VEIKI-VNL Germany France Italy Belgium Sweden Spain Hungary Providing specific conditions are fulfilled, ALPHA can also issue officially recognized product certificates if required. As a member of LOVAG, ALPHA is also working towards obtaining international recognition for declarations of conformity and certificates. LOVAG (Low-Voltage Agreement Group) is a body comprising international specialists from certification bodies and industry who are working together to create a standardized European certificate. ■ Accident prevention 20 Test certificates and approvals from the BIA (German statutory industrial accident insurance institution in Bonn) and from SUVA (Swiss institute for accident prevention) are available for some devices in safety control systems. For details, see the respective product descriptions. Siemens LV 1 · 2008 20/15 LV1_20.book Seite 16 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals ■ Ex protection certificates for SIRIUS controls Motor protection devices that protect a motor installed in a potentially explosive atmosphere against overloading must comply with certain special requirements. These requirements are laid down in the following standards: • EN 60079-0 • EN 60079-1 • EN 60079-7 • EN 60079-14 • EN 60079-17 • EN 60947-1 • EN 60947-4-1 • EN 60947-5-1 • EN 60947-8 Certification July 1, 2003 saw the dawning of a new era in the field of explosion protection. Since this date, only those devices and protection systems that have been certified for operation in potentially explosive atmospheres according to directive 94/9/EC can be brought into circulation within the European Union. Only those motor protection devices that have been constructed according to the above-mentioned standards and which have a conformity declaration from the manufacturer based on a prototype test certificate may be brought into circulation within the member states of the EC. The quality management system of the manufacturer is also subjected to certain requirements and a "QM certificate" must be obtained for the manufacturer from a recognized authority. ■ Certificate of the AS-International Association for AS-Interface products 20 AS-Interface products are tested and certified by the AS-International Association. The products have been tested in an accredited test laboratory according to testing guidelines. 20/16 Siemens LV 1 · 2008 Certification of the QM system A certificate of approval for quality assurance production has been issued by DEKRA EXAM GmbH1) with the number BVS 05 ATEX ZQS/E111 of DEKRA EXAM GmbH1) according to Directive 94/9/EC. This certificate is valid for equipment groups I and II and categories M2 and 2: Safety and control devices for electrical equipment. Certificates For the 3RV, 3RU, 3RB, 3UF, 3RN and 3RW motor protection devices, the corresponding conformity declarations and prototype test certificates for Category 2G, and to some extent 2D, are available and can be supplied on request. More details can also be found in the section "Type overview of approved devices for potentially explosive areas (ATEX explosion protection)" on Page 20/27. Identifying markings All equipment must be marked according to the ATEX guideline. The ATEX identification code contains the equipment group, the approved environment, the number of the certification authority and other technical data that was determined from the type test. 1) DEKRA EXAM GmbH The certification authority of the "DEKRA EXAM GmbH" numbered as authority number 0158 according to Article 9 of Directive 94/9/EC of the European Parliament and Council dated March 23, 1994, certifies that Siemens Amberg and Cham maintains a quality system for production that satisfies Appendix IV of this Directive. LV1_20.book Seite 17 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals ■ Special specifications for the USA and Canada In the USA and Canada, for machine tools and processing machines in particular, supply lines are laid using rubber insulated cable enclosed in heavy-duty steel piping similar to that used for gas or water pipe systems. only approved by CSA and UL for "Heavy Duty" or "Standard Duty" and are identified either with these specifications in addition to the maximum permissible voltage or by using an abbreviation. The tubing system must be completely watertight and electrically conductive (especially sleeving and elbows). Since the tubing system can also be grounded, the cable entries of enclosed units equipped with heavy-gauge or metric threads must be fitted with metal adapters between these threads and the tube thread. The necessary adapters are specified for the switchgear as accessories; they should be ordered separately unless otherwise specified. The abbreviations are harmonized with IEC 60947-5-1 Appendix 1 Table A1 and correspond to the stated utilization categories. For various switching devices detailed in the catalog, a note has been included to the effect that, above a certain voltage, the auxiliary switches/auxiliary contacts can only be used if they have the same polarity. This means that the input terminals can only be connected to the same pole of the control voltage, e.g. "600 V AC above 300 V AC same polarity". Low-voltage switchgear and controlgear for auxiliary circuits (e.g. contactor relays, commanding and signaling devices and auxiliary switches/auxiliary contacts in general) are generally Different features of UL approvals (for USA and Canada) Recognized Component Listed Product UL issues yellow "Guide cards" with a Guide No. and a File No. UL issues white "Guide cards" with a Guide No. and a File No. Devices are identified on the rating plate using the "UL recognition mark": USA: U, cUUS Canada: cU, cUUS Devices are identified using the "UL listing mark" on the rating plate e.g. USA: u LISTED 165 C Canada: cu LISTED 165 C IND. CONT. EQ. IND. CONT. EQ. (165 C stands for: Siemens, A&D CD Division, Amberg plant) Devices are approved as modules for "factory wiring", i.e.: as devices for installation in control systems, which are selected, installed, wired and tested entirely by trained personnel in factories, workshops or elsewhere, according to the operating conditions. Devices are approved for "field wiring", i.e.: • As devices for installation in control systems, which are completely wired by trained personnel in factories, workshops or elsewhere. • As single devices for sale in retail outlets in the USA/Canada. If devices are u or cu approved as "listed products", they are also approved as U or cU "recognized components". For more information about UL and CSA, see Page 20/14. ■ Special specifications for Russia, Australia and China GOST approval for Russia A 46 CCC approval Since August 1, 2003, CCC approval is required for many products that are marketed in China. A GOST approval is required for all products that are to be sold in Russia. The GOST mark has been obligatory on the packaging of all devices since mid-1998. All devices delivered to any part of the Russian Federation must have this customs certification. C-Tick licensing for Australia 20 The C-Tick license is required for marketing Siemens components in Australia. Electronic devices must provide proof of EMC clearance in Australia, similar to the CE mark of conformity laid down by the EMC directive applicable in the EC and bear the "C-Tick" mark. These requirements have been in force since October 1st, 1999. Siemens LV 1 · 2008 20/17 LV1_20.book Seite 18 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals ■ Type overview of approved devices Devices Type Approvals Canada 1) 2) Marine classifications USA 1) 1) China Germany United France Kingdom Norway CIS Italy Poland USA s u U CCC GL LRS BV DNV RMRS RINA PRS ABS + + × + +/∆ +/∆ +/∆ +/∆ O +/∆ +/∆ +/∆ ECOFAST motor 3RK1 323 + starters (available soon) 6EP16 32-1AL01 + + x + -- -- -- -- -- -- -- -- + -- -- -- -- -- -- -- -- -- Motor starters 3RK1 322 PROFIBUS DP ET 200X motor starters 3RK1 300 + + × + + + + + -- + + + ET 200S 3RK1 301 + + × + -- -- -- -- -- -- -- -- ECOFAST 3RK1 303 + + x + -- -- -- -- -- -- -- -- ET 200pro 3RK1 304 O + x O -- -- -- -- -- -- -- -- ECOFAST accessories ET 200X accessories 3RK1 9 + + × + +/∆ +/∆ +/∆ +/∆ -- +/∆ +/∆ +/∆ 3UF5 + + × + + + -- + -- -- -- -- 3UF7 + + x + O O -- O -- -- -- -- Current transformers 3UF18 + + × -- -- -- -- -- -- -- -- LOGO! Basic variant AS-i variant Expansion module 6ED1 052 6ED1 055 + + + + × × + + + + + + + + --- --- + + + + SIRIUS motor starter protectors up to 100 A4) for Motor protection 3RV10 11 3RV10 21 3RV10 31 3RV10 4. + +3) +3) +3) + +3) +3) +3) + × × × + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ----- Motor protection with overload relay function 3RV11 21 3RV11 31 3RV11 4. + + + + + + × × × + + + ---- ---- ---- ---- + + + ---- + + + ---- Starter combinations 3RV13 21 3RV13 31 3RV13 4. + + + + + + × × × + + + + + + + + + ---- + + + + + + + + + + + + ---- Fuse monitoring 3RV16 11.1 + + x + -- -- -- -- + -- + -- Transformer protection 3RV14 21 3RV14 31 +4) +4) +4) +4) × × + + + + + + + + + + + + + + + + --- System protection according to UL489 Transformer protection according to UL489 3RV17 21 3RV17 42 3RV18 21 + + + + + + × × x O O O ---- ---- ---- ---- ---- ---- ---- ---- Auxiliary switch 3RV19 01 + + × + + + + + + + + -- Undervoltage trip units / shunt trip units 3RV19 .2 + + × + + + + + + + + -- Door-coupling rotary operating mechanisms 3RV19 36/46 + + x + -- -- -- -- -- -- -- -- Busbars Isolator modules Scale covers Molded-plastic enclosures Solder pin connections Cast aluminum enclosures for surface mounting Terminal blocks type E 3RV19 .7 3RV19 .8-1A 3RV19 08 3RV19 13 3RV19 18 3RV19 23 + + --+ -- + + --x -- x x --+ -- + + + + + + + + + -+ -- + + + -+ -- + + + -+ -- + + + -+ -- + + + -+ -- + + + -+ -- + + + -+ -- ------- 3RV19 28-1H + + -- + + + + + + + + -- Feeder terminals Feeder terminals type E 3RV19 15 3RV19 35 + + + + × × + + + + + + + + + + + + + + + + --- Alarm switches 3RV19 21-1M + + × + + + + + + + + -- SIMOCODE Accessories 5) 20 + Standard version approved. -- Not yet submitted for approval. O Device submitted for approval, please inquire. × U approval not required because u approved. ∆ Note remarks on marine products (AS-Interface), see http://www.siemens.com/automation/support. 20/18 Siemens LV 1 · 2008 1) For guide numbers and file numbers for the approvals, visit our website at http://www.siemens.com/automation/support. 2) cu and cU approvals are available in accordance with US approval. 3) Approval as "Type E" combination motor controller and as tap conductor protection device. 4) Approval for motorized loads only (not for transformers) 5) For approved rated data, please see chapter 5, "Protection equipment: Motor starter protectors". LV1_20.book Seite 19 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals Devices Type Approvals Marine classifications Canada USA 1) 1) 1) 2) China Germany United France Kingdom Norway CIS Italy Poland USA s u U CCC GL LRS BV DNV RMRS RINA PRS ABS 3RT10 1. 3RT10 2. 3RT10 3. 3RT10 4. + + + + + + + + × × × × + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ----- 3RT10 5.-.A 3RT10 5.-.N 3RT10 5.-.P 3RT10 5.-.Q + + + + + + + + x x x x + + + + + + + + + + + + ----- + + + + ----- ----- ----- ----- 3RT10 6.-.A 3RT10 6.-.N 3RT10 6.-.P 3RT10 6.-.Q + + + + + + + + x x x x + + + + + + + + + + + + ----- + + + + ----- ----- ----- ----- 3RT10 7.-.A 3RT10 7.-.N 3RT10 7.-.P 3RT10 7.-.Q + + + + + + + + x x x x + + + + + + + + + + + + ----- + + + + ----- ----- ----- ----- 3RT12 6.-.A 3RT12 6.-.N + + + + × × + + + + + + --- + + --- --- --- --- 3RT12 7.-.A 3RT12 7.-.N + + + + x x + + + + + + --- + + --- --- --- --- 3RT14 4. + + × + + + -- + -- -- -- -- 3RT14 56-.A 3RT14 56-.N 3RT14 56-.P 3RT14 56-.Q + + + + + + + + × × x x + + + + + + + + + + + + ----- + + + + ----- ----- ----- ----- 3RT14 66-.A 3RT14 66-.N 3RT14 66-.P 3RT14 66-.Q + + + + + + + + x x x x + + + + + + + + + + + + ----- + + + + ----- ----- ----- ----- 3RT14 76-.A 3RT14 76-.N 3RT14 76-.P 3RT14 76-.Q + + + + + + + + x x x x + + + + + + + + + + + + ----- + + + + ----- ----- ----- ----- SIRIUS 3RT 4-pole contactors 3RT13 3RT15 + + + + × × + + --- --- --- --- --- --- --- --- SIRIUS 3RT16 capacitor contactors 3RT16 + + × + -- -- -- -- -- -- -- -- SIRIUS 3RH contactor 3RH11 22-2K relays (extended operating range) + + × + + + + + + + + -- SIRIUS coupling relays 3RT10 3RH11 + + + + × x + + + + + + + + + + + + + + + + --- Accessories for 3RT and 3RH + + + + + + + + + + × × × × × + + + + + + + + + -- + + + + -- + + + + -- + + + + -- + + + + -- + + + + -- + + + + -- ------ SIRIUS 3RT12 vacuum contactors SIRIUS 3RT14 contactors for switching resistive loads 3RH19 11 3RH19 21 3RT19 .6-1.... 3RT19 .6-2.... 3RT19 46-4GH07 + Standard version approved. -- Not yet submitted for approval. O Device submitted for approval, please inquire. × U approval not required because u approved. ∆ Note remarks on marine products (AS-Interface), see http://www.siemens.com/automation/support. 1) For guide numbers and file numbers for the approvals, visit our website at http://www.siemens.com/automation/support. 2) cu and cU approvals are available in accordance with US approval. 20 SIRIUS 3RT10 contactors Siemens LV 1 · 2008 20/19 LV1_20.book Seite 20 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals Devices Type Approvals Canada 1) 2) Marine classifications USA 1) 1) China Germany United France Kingdom Norway CIS Italy Poland USA s u U CCC GL LRS BV DNV RMRS RINA PRS ABS SIRIUS 3RA13 reversing contactors 3RA13 1. + + × + + + + + + + + -- SIRIUS 3RA14 wye-delta combinations 3RA14 1 -- -- × + + + + + + + -- -- Accessories for 3RA1 3RA19 13-2B 3RA19 13-3K 3RA19 23-2B 3RA19 23-3B 3RA19 24-.. 3RA19 33-2B 3RA19 43-2B 3RA19 .6-4B + -+ + + + + + + -+ + + + + + × × × × × × × × + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + --------- 3-phase EMC inter- 3RT19 16 ference suppression modules + + – + + + + + + + + – 3TF68/3TF69 contactors 3TF68 ..-0C 3TF68 ..-1D 3TF68 ..-1Q 3TF68 ..-8C 3TF68 ..-8D 3TF68 ..-8Q 3TF69 ..-0C 3TF69 ..-1D 3TF69 ..-1Q 3TF69 ..-8C 3TF69 ..-8D 3TF69 ..-8Q + + + + + + + + + + + + + + + + + + + + + + + + × × × x x x × × × x x x + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ------------- ------------- ------------- 3TG10 contactors 3TG10 ...-0 + + × + -- -- -- -- -- -- -- -- 3TD reversing contactor assemblies 3TD68 + + × -- -- -- -- -- -- -- -- -- Surge suppressors 3TX7 4, 3TX7 522 + + × -- -- -- -- -- -- -- -- -- 3TK1 contactors 3TK1 with 4 NO main contacts +2) + × + -- -- -- -- -- -- -- -- 3T contactors with 3T... ..-0L extended operating range + + × -- -- -- -- -- -- -- -- -- SIRIUS 3RF2 solid-state switching devices 3RF2 + + × + -- -- -- -- -- -- -- -- Contactor relays 3RH11⁄12, 3RH14 3TH42, 3TH43 + + + + × × + + + + + + + + + + + + + + + + 3RU11 thermal overload relays 3RU11 1. 3RU11 2. 3RU11 3. 3RU11 4. + + + + + + + + × × × × + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ----- 3RB2 solid-state overload relays 3RB20, 3RB21 3RB22, 3RB23 + + + + × × O + + + + + --- + + --- --- --- --- Accessories 3RU19 .6-3A 3RU19 00-1 3RU19 00-2 3RB29.3-0AA1 + + + + + + + + × × × x + + + O + + + + + + + + + + + -- + + + + + + + -- + + + -- + + + -- ----- 3RA11, 3RA12 SIRIUS 3RA11/3RA12/3RA5 3RA5 load feeders +3) -- +3) -- × × + + + O + O + -- + + --- --- + -- --- 3RE encapsulated starters -- -- -- -- -- -- -- -- -- -- -- -- 3RE 20 + Standard version approved. -- Not yet submitted for approval. O Device submitted for approval, please inquire. × U approval not required because u approved. 20/20 Siemens LV 1 · 2008 1) For guide numbers and file numbers for the approvals, visit our website at http://www.siemens.com/automation/support. 2) cu and cU approvals are available in accordance with US approval. 3) Single devices approved for assemblies. LV1_20.book Seite 21 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals Devices Type Approvals Marine classifications Canada USA 1) 1) 1) 2) China Germany United France Kingdom Norway CIS Italy Poland s u U CCC GL LRS BV DNV RMRS RINA PRS SIRIUS solid-state soft 3RW30, 3RW31 starters 3RW40 2 ... 3RW40 4 3RW40 5, 3RW40 7 3RW44 2, 3RW44 3 3RW44 4 3RW44 5, 3RW44 6 + O + + + O + O + + + O × × × × × × + O + + + O + O + O O O + O + O O O ------- + O + O O O ------- ------- + + ----- SIRIUS timing relays 3RP15 3RP20 + +2) + + × – + + + O + O + -- + + + -- + -- + -- 7PV3 7PV4 +2) +2) --- + + --- --- --- --- --- --- --- --- SIRIUS temperature monitoring relays 3RS10 3RS11 + + + + --- + + --- --- --- --- --- --- --- SIRIUS thermistor motor protection 3RN1 + + × + + + + + -- -- + SIRIUS monitoring relays 3UG3 +2) + + -- -- -- -- -- -- -- -- 3UG4 +2) + + O + O -- O -- -- -- SIRIUS coupling links, 3RS18 3TX7 011) narrow design 3TX7 002, 3TX7 003 3TX7 004, 3TX7 005 + + + + + + + + × × × × m m m m ----- ----- ----- ----- ----- ----- ----- SIRIUS plug-in relays, LZX:MT relay couplers LZX:PT LZX:RT LZX:RY +2) +2) +2) +2) ----- + + + + O O O O ---- ---- ---- ---- ---- ---- ---- SIRIUS power relays 3TG10 ..-0 + + × + -- -- -- -- -- -- -- Interface converters/ isolation amplifiers 3RS17 +2) + -- m -- -- -- -- -- -- -- Standard position switches 3SE2 100/120 3SE3 0 + + + + × + + + k k k k k k k k --- k k k k 3SE2 200/210/230 + + + k k k k -- k k 3SE5 232, 3SE5 234, 3SE5 242, 3SE5 250 + + × O k k k k -- k k 3SE5 112, 3SE5 114, 3SE5 115, 3SE5 122 + + × O -- -- -- -- -- -- -- 3SF1 1, 3SF1 2 3SF1 3 + + + + × × O O --- --- --- --- --- --- --- 3SE2 120-1X. 3SE2 120-6XX + + + + × × + + k k k k k k k k --- k k k k 3SE2 240 3SE2 243/257 + + + + × × + + k k k k k k k k --- k k k k Safety position switches 3SE3 160/180 -- + × -- -- -- -- -- -- -- -- 3SE2 83., 3SE2 84. 3SE2 9 + + + + x x + + --- --- --- --- --- --- --- 3SE5 0 + -- × O -- -- -- -- -- -- -- 3SE5 1, 3SE5 2 3SE5 25, 3SE5 3 + + + + × × O O --- --- --- --- --- --- --- 3SE5 312, 3SE5 322 + + × O -- -- -- -- -- -- -- 8WD4/8WD5 + + × -- k k k k -- k k Magnetically operated 3SE6 switches + + × -- -- -- -- -- -- -- -- Cable-operated switches 3SE7 + + × -- -- -- -- -- -- -- -- Safety combinations 3TK28 21 bis 3TK28 24, + 3TK28 30 3TK28 25, 3TK28 27/28 + 3TK28 34, 3TK28 35 + + × O -- -- -- -- -- -- -- + + × × O O --- --- --- --- --- --- --- + + + + + + × × × O O O ---- ---- ---- ---- ---- ---- ---- 3TK28 40 to 3TK28 45 3TK28 50 to 3TK28 57 3RA71 + Standard version approved. -- Not yet submitted for approval. O Device submitted for approval, please inquire. × U approval not required because u approved. k Approved for operation in connection with AS-Interface (Actuator Sensor Interface), also approved by ABS (American Bureau of Shipping). m For exporting products to the People’s Republic of China, CCC marking is not necessary. 1) For guide numbers and file numbers for the approvals, visit our website at http://www.siemens.com/automation/support. 2) cu or cU approval. 20 Signaling columns Siemens LV 1 · 2008 20/21 LV1_20.book Seite 22 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals Devices Type Approvals Marine classifications Canada USA China 1) 1) Germany United France Kingdom Norway CIS Italy Poland s u U CCC GL LRS BV DNV RMRS RINA PRS + + + + + + + + × × × × + + + + ----- ----- ----- ----- ----- ----- ----- + + + + + + + + × × x × + + + + k k k k k k k k k k -- -- -- -- -- k k k k ----- k k -- k k + -- + + k k k k -- k k + + + + × × + + -k -k -k -k --- -k -k + + + + × × + + k k k k k k k k --- k k k k 1) 2) Pushbutton units and Actuators with holders, indicator lights, nomi- complete units, lampnal diameter 16 mm holders, contact blocks and voltage reducers 3SB20 3SB22 3SB23 3SB24 Pushbutton units and indicator lights3), nominal diameter 22 mm, round type Actuators with holders, complete units, switching elements, lampholders and transformers (screw and solder pin terminals) 3SB30 3SB32 3SB323 3SB34 (screw terminals) 3SB34 (solder connection) 3SB35/3SB36 3SB38 Pushbutton units and indicator lights3), mounting cutout 26 × 26 mm Actuators with holders, complete units, switching elements, lampholders and transformers (screw and solder pin terminals) 3SB31 3SB33 + Standard version approved. -- Not yet submitted for approval. O Device submitted for approval, please inquire. × U approval not required because u approved. k Approved for operation in connection with AS-Interface (Actuator Sensor Interface), also approved by ABS (American Bureau of Shipping). For guide numbers and file numbers for the approvals, visit our website at http://www.siemens.com/automation/support. 2) cu and cU approvals are available in accordance with US approval. 3) A test certificate has been issued for EMERGENCY-STOP command devices and switching elements with screw or solder pin terminals by the BIA (German statutory industrial accident insurance institution). 20 1) 20/22 Siemens LV 1 · 2008 LV1_20.book Seite 23 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals Devices Type Approvals Marine classifications Canada USA 1) 1) 1) 2) China Germany United France Kingdom Norway CIS Italy Poland USA CCC SENTRON WL circuit breakers up to 6300 A (ACB) 3WL1 3WL5 s --- u -+ U --- + -- GL + -- LRS + -- BV + -- DNV + -- RMRS + -- RINA + -- PRS ABS + ............ + -- SENTRON VL circuit breakers up to 1600 A (MCCB) 3VL1/2/3/4 3VL5/6/7/8 3VL9 ---- ---- + + + + + + + + + + + + + + + + + + + + + + + + + ............ + + ............ + + ............ + SENTRON VL circuit breakers up to 1600 A (MCCB) (UL/CSA version) 3VL1 3VL2/3/4/4X 3VL6/7/8 3VL9 O + + + O + + + x x x x O O O O ----- ----- ----- ----- ----- ----- ----- 3VF molded case circuit breakers up to 2500 A 3VF2 -- -- -- + -- -- -- -- -- -- -- 3NP35/3NP40 1 -- -- +4) O + -- -- -- -- -- + 3NP35/3NP40 7 -- -- +4) O -- -- -- -- -- -- -- 3NP35/3NP4 -- -- -- O -- -- -- -- -- -- + 3NP50 to 3NP54 3NP5. 6.–.H 3NJ4 ---- ---- ---- O O + ---- ---- ---- ---- ---- ---- + + -- Switch disconnectors 3NJ6 1 with fuses up to 630 A -- -- -- + + + -- + -- -- -- Switch disconnectors 3KL50, 3KM50 with fuses up to 800 A 3KL52, 3KM52 3KL53, 3KM53 ---- ---- -+3) +3) O O O + + -- + + -- + --- ---- + --- ---- + + + 3KL55, 3KM55 3KL57, 3KM57 --- --- +3) +3) O O + + + + --- --- --- --- + + Fuse switch disconnectors up to 630 A Fuse switch disconnectors up to 1250 A 3KL61 3KL62 --- --- +3) 3) + O O --- --- --- --- --- --- + -- SITOR fuses 3NE 3NC 3NC1 09, 3NC1 49 3NC2 29 --+ + ----- + + + + O O O O ----- ----- ----- ----- ----- ----- ----- LV HRC fuse links 500 V AC/440 V DC 3NA3 00., 3NA3 010 3NA3 012 -+ --- --- --- --- --- --- --- + + --- 3NA3 014, 3NA3 017 3NA3 02., 3NA3 03. + + --- --- --- --- --- --- --- + + --- 3NA3 10., 3NA3 110 3NA3 114, 3NA3 117 -+ --- --- + + -+ --- --- --- -+ --- 3NA3 12., 3NA3 13. 3NA3 14. + + --- --- + + + + --- --- --- + -- --- 3NA3 214 3NA3 220, 3NA3 222 3NA3 224, 3NA3 23. --+ ---- + + + ---- ---- ---- ---- --+ ---- 3NA3 240 3NA3 242, 3NA3 244 + + --- --- + + -+ --- --- --- + + --- 3NA3 250 3NA3 252, 3NA3 260 3NA3 254 + + + ---- ---- + + + -+ -- ---- ---- ---- + + + ---- 3NA3 340, 3NA3 340 3NA3 35., 3NA3 360 -+ --- --- + + --- --- --- --- -+ --- 3NA3 362, 3NA3 365 3NA3 372 --- --- --- + + --- --- --- --- + + --- 3NA3 47., 3NA3 480 3NA3 6.. --- --- --- --- --- --- --- --- --- --- 3NA3 801, 3NA3 803 3NA3 802, 3NA3 804 3NA3 805, 3NA3 807 ---- ---- ---- + + + + -+ ---- ---- ---- + -+ ---- 3NA3 810 3NA3 812, 3NA3 814 3NA3 817, 3NA3 82. -+ + ---- ---- + + + + + + ---- ---- ---- + + + ---- 3NA3 830 3NA3 832 3NA3 836 + + -- ---- ---- + + + + --- ---- ---- ---- + -+ ---- 3NA3 1.. 3NA3 2.. 3NA3 3.. ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 3NA3 80., 3NA3 810 3NA3 812, 3NA3 817 --- --- --- --- --- --- --- --- --- --- 3NA3 814 3NA3 82., 3NA3 830 --- --- --- --- --- --- --- --- --- --- + Standard version approved. -- Not yet submitted for approval. O Device submitted for approval, please inquire. × U approval not required because u approved. 1) For guide numbers and file numbers for the approvals, visit our website at http://www.siemens.com/automation/support. 2) cu and cU approvals are available in accordance with US approval. 3) Fpr approved rated data, see Chapter 17 4) Approved as fuse base. 20 LV HRC fuse links 690 V AC Siemens LV 1 · 2008 20/23 LV1_20.book Seite 24 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals Devices Type Approvals Canada 1) 2) s Switch disconnectors cUUS +3) +3) 1) 1) China Germany United France Kingdom Norway CIS Italy Poland USA u cuUS U CCC GL LRS BV DNV RMRS RINA PRS ABS --- --- --- O O + -- + -- + -- --- + -- --- + + --- × × +3) +3) --- × × O O -+ --- --- --- --- --- + + --- 3KA50 -3KA51, 3KA55, 3KA58 -3KA53 3KA57 Marine classifications USA 3KE4 -- -- -- -- -- -- -- -- -- -- + -- + Busbar adapter systems 8US14) + + -- -- + -- -- -- -- -- -- -- -- -- Transformers 4AM, 4AP, 4AT, 4AU 5) 4BT, 4BU 4AX, 4FK ---- + + -- ---- ---- + + -- m m m --7) --7) --7) --7) --7) --7) --7) --7) --7) --7) --7) --7) ---- ---- + -+ --7) --7) --7) Power supplies 4AV21, 4AV23 -- + -- -- + m --7) --7) --7) --7) -- -- + --7) 7) 7) -- 7) 7) -- -- + --7) 4AV20, 4AV22, 4AV24, 4AV26 -- + -- -- + m -- 4AV30 ... 4AV35 6EP1 -+6) + -- --- --- + x m m -+6) -+6) --- -+6) --- --- + -- -+6) Control switches and main control switches Basic units and flush-mounting switches 3LD2 3LD2. 64 ... 3LD2. 66 + + × × + + --- × -- + + + -- + -- --- + -- --- --- + -- --- Molded-plastic distribution systems 8HP -- -- O -- -- -- -- -- -- -- -- -- -- -- 20 + Standard version approved. -- Not yet submitted for approval. O Device submitted for approval, please inquire. × U approval not required because u approved. m For exporting products to the People’s Republic of China, CCC marking is not necessary. 20/24 Siemens LV 1 · 2008 -- -- 1) For guide numbers and file numbers for the approvals, visit our website at http://www.siemens.com/automation/support. 2) cu and cU approvals are available in accordance with US approval, unless otherwise specified. 3) For u, cu and s approved rated data see Chapter 16, "Molded-case circuit breakers (MCCB)". 4) Not all components are approved. 5) Transformers according to EN 61558-2-15 are not U, cU and cUus approved. 6) Partly; for details see Catalog KT 10.1, "SITOP Power Power Supply". 7) On request, single devices can be certified according to GL, LRS, DNV and ABS. LV1_20.book Seite 25 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals Type Approvals Canada 1) 2) Terminal blocks For s and U approved ratings of terminals blocks see Technical specifications 8WA1 010-1PH01 8WA1 010-1PQ00 Marine classifications USA 1) 1) China Czech Slova- Polan HunRepub kia d gary lic Germany United Franc Nor- CIS King- e way dom Italy Poland USA s cUUS u SKTC SEP MEEI GL LRS BV DNV RMRS RINA PRS ABS + + --- --- --- + -- --- --- + -- --- --- --- --- --- + -- --- cuUS U CCC EZU 8WA1 011-0D + -- + + + -- + + + + + -- -- + + 8WA1 011-1BF21 8WA1 011-1BF22 8WA1 011-1BF23 8WA1 011-1BF24 8WA1 011-1BF25 + + + + + ------ + + + + + + + + --- + + + --- ------ + + + --- + + + + -- + + + + -- + + + + -- + + + + -- ------ ------ + + + --- + + + + -- 8WA1 011-1BG11 8WA1 011-1BG21 8WA1 011-1BG22 8WA1 011-1BG24 + + + + ----- + + + + + + + -- + + + -- ----- + + + -- + + + + + + + + + + + + + + + + ----- ----- + + + -- + + + + 8WA1 011-1BH23 8WA1 011-1BH24 8WA1 011-1BK11 8WA1 011-1BM11 8WA1 011-1BP11 + + + + -- ------ + + + + -- + -+ + + + -+ + + ------ + -+ + + + + + + + + + + + + + + + + + + + + + + ------ ------ --+ + + + + + + + 8WA1 011-1DF11 8WA1 011-1DG11 8WA1 011-1DH11 8WA1 011-1DQ10 8WA1 011-1DS10 8WA1 011-1DU10 + + + ---- ------- + + + + + + + + + + + + + + + ---- ------- + + + ---- + + + ---- + + + ---- + + + ---- + + + ---- ------- ------- + + + ---- + + + ---- 8WA1 011-1EF20 8WA1 011-1MH1. -+3) --- -+ + + -+ --- + + -+ -+ -+ -+ --- --- + + -+ 8WA1 011-1EF28 8WA1 011-1NF01 8WA1 011-1NF02 8WA1 011-1NG31 8WA1 011-1NG32 -+ + + + ------ -+ + + + -+ ---- -+ ---- ------ + + -+ -- -+ + + + -+ + + + -+ + + + -+ + + + ------ ------ -+ + + + -+ + + + + Standard version approved. -- Not yet submitted for approval. + + + 1) For guide numbers and file numbers for the approvals, visit our website at http://www.siemens.com/automation/support. 2) cu and cU approvals are available in accordance with US approval, unless otherwise specified. 3) 600 A, 5 A, type D or 300 V type C. 20 Devices Siemens LV 1 · 2008 20/25 LV1_20.book Seite 26 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals Devices Type Approvals Canada USA Marine classifications 1) 2) 1) 1) Czech Slova- Poland HunRepub kia gary lic Germany United France NorKingway dom CIS Italy Poland USA s u U EZU SKTC SEP MEEI GL LRS BV DNV RMRS RINA PRS ABS Terminal blocks 8WA1 011 -1NH01 For s and U approved -1NH02 ratings of terminals -1NK02 blocks see Technical specifications + + -- ---- + + + + --- + -+ ---- + --- + + + + + + + + + + + + ---- ---- + + + + + + 8WA1 011 -1PF00 -1PF01 -1PF11 + + + ---- + + + + + + + + + ---- + + + + + + + + + + + + + + + ---- ---- + + + + + + 8WA1 011 -1PG00 -1PG01 -1PG11 + + + ---- + + + + + + + + + ---- + + + + + + + + + + + + + + + ---- ---- + + + + + + 8WA1 011 -1PH00 -1PH11 -1PK00 -1PM00 + + + + ----- + + + + + + --- + + + -- ----- + + + + + + + + + + + + + + + + + + + + ----- ----- + + + + + + + + 8WA1 011 -1SF12 -1SF2. + + --- + + + -- + + --- + -- + -- + -- + -- + -- --- --- + + + -- 8WA1 011 -2BG11 -2DG11 -2SF2. + + + ---- + + + + + -- -+ + ---- -+ -- + + -- + + -- + + -- + + -- ---- ---- + + + + + -- 8WA1 011 -3D.21 + -- + + + -- + + + + + -- -- + + 8WA1 011-3JF16 to 8WA1 011-3JF20 + -- + + + -- + -- -- -- -- -- -- -- -- 8WA1 011 -4SF2. -6SF2. -8SF2. + --- ---- + --- ---- + + + ---- ---- ---- ---- ---- ---- ---- ---- + + + ---- 8WA1 011 -6BG11 -6DG11 -6EG.. + + -- ---- + + + + + + -+ + ---- -+ + + + -- + + -- + + -- + + -- ---- ---- + + + + + -- 8WA1 012 -1DK10 -1D.14 -+ --- + + --- --- --- --- --- --- --- --- --- --- --- --- 8WA1 204 to 206 + -- + + + -- + + + + + -- -- + + 8WA1 211, 8WA1 221 8WA1 232 --- --- -+ --- + + --- --- --- --- --- --- --- --- + + --- 8WA1 304, 8WA1 305 8WA1 501 8WA1 604 + + -- ---- + + + + -+ + -+ ---- + -+ + -+ + -+ + -+ + -+ ---- ---- + -+ + -+ 20 + Standard version approved. -- Not yet submitted for approval. 20/26 Siemens LV 1 · 2008 1) For guide numbers and file numbers for the approvals, visit our website at http://www.siemens.com/automation/support. 2) cu and cU approvals are available in accordance with US approval. LV1_20.book Seite 27 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals ■ Type overview of approved devices for potentially explosive areas (ATEX explosion protection) Type Certificate number Certification based on Type of protection/ Identification ATEX 2705 EN 60947-5-2, EN 50281-1-1 Ex II (3) D X DMT 02 ATEX F 001, DMT 02 ATEX F 001 N1 IEC 60947-4-1, EN 60079-14 Ex II (2) GD PTB 06 ATEX 3001 EN 60079-1, EN 60079-7, EN 60079-14, IEC 60947-4-1, IEC 60947-5-1, IEC 60947-8 IEC 61508 Ex II (2) GD DMT 98 ATEX G 001, DMT 98 ATEX G 001 N1 IEC 60079-14, EN 60079-14 Ex II (2) GD Systems Digital I/O modules IP67 Series 3RK1 400-1DQ05-0AA3 K60 3RK1 200-0CQ05-0AA3 Contactors1) Motor starter protectors For motor protection Size 3RV10 11 S00 3RV10 21 S0 3RV10 31 S2 3RV10 41 S3 3RV10 42 S3 For standard applications 3RB20, 3RB21 S00 ... S12 For high-feature applications 3RB22, 3RB29 3RB solid-state overload relays PTB 05 ATEX 3022 3RU1 thermal overload relays For standard applications 3RU11 1 S00 3RU11 2 S0 3RU11 3 S2 3RU11 4 S3 Starting Soft starters For standard applications Size 3RW40 S6, S10/S12 BVS 05 ATEX F 002 EN 60079-14, IEC 60947-4-2, IEC 61508 Ex II (2) GD 3RK13 01 S00 DMT 02 ATEX F 001, DMT 02 ATEX F 001 N1 IEC 60947-4-1, EN 60079-14 Ex II (2) GD BVS 06 ATEX F 001 EN 60079-1, EN 60079-7, EN 60079-14, IEC 60947-4-1, IEC 60947-5-1, IEC 60947-8, IEC 61508 Ex I (M2), Ex II (2) GD PTB 01 ATEX 3219 EN 50019, EN 60079-7, EN 60079-14, IEC 60079-7 Ex II (2) G EN 50281-1-1 Ex II (2) GD ET200S motor starters Standard motor starters Monitoring and control1) Size For motors with constant speeds S00 ... S12 3UF7 SIMOCODE-DP motor protection and control devices Size For motors with constant speeds S00 ... S12 3UF5 3UF5 ...-...0 1) Information for the implementation of current monitoring motor protection devices. Definition of the locked-rotor time tE: If the rotor of an explosion-protected induction motor of protection type "Increased Safety" EEx e stalls (locks) at operating temperature during runtime, the motor must be switched off, at the very latest, when either the rotor or the stator winding have reached their maximum temperature. The time that elapses until the rotor or stator winding has reached maximum temperature is called the locked-rotor time tE or tE time. The demands made on overload protective devices with regard to tE time: For trip units and relays with inverse-time delayed operation, tripping characteristics must be available at the operating site. The characteristic curves should show the tripping time for 3-pole loading, assuming a cold state and a room temperature of 20 °C, depending on at least a 3- to 8-fold setting current. The protective devices must comply with the specified tripping times with a permissible deviation of ± 20 %. The trip units and relays for machines with cage rotors must be selected such that the tripping times for 3-pole loading do not exceed the locked-rotor time tE specified on the type plate. For information on the tripping characteristics of our circuit breakers and overload relays, visit our web site at: http://www.siemens.com/lowvoltage/manuals 20 SIMOCODE pro motor management and control devices Siemens LV 1 · 2008 20/27 LV1_20.book Seite 28 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Standards and approvals Type Certificate number Certification based on Type of protection/ Identification PTB 01 ATEX 3218 EN 60079-14, IEC 60947-8, IEC 60947-1 IEC 60947-5-1 EN 50281-1-1 Ex II (2) G EN/IEC 61241-0 EN/IEC 61241-1 Ex II 3D Simple electrical apparatus according to EN 50020, IEC 60947-5-1 Application only in circuits of type of protection i (intrinsic safety) according to EN 50020 Simple electrical apparatus according to EN 50020, IEC 60947-5-1 Application only in circuits of type of protection i (intrinsic safety) according to EN 50020 Monitoring and control1) (continued) Thermistor motor protection relays For PRC sensors (PTCs typ A) Width (mm) 3RN10 22.5; 45 3RN10 11-.B, 3RN10 11-.G, 3RN10 12-.B, 3RN10 12-.G, 3RN10 13-…0 22.5 Ex II (2) GD Detecting Position switches and cable-operated switches Width 3SE5 112-.....-1DA0 56 mm 3SE5 122-.....-1DA0 40 mm ATEX 2829 Commanding and signaling Actuators Version Actuator 3SB30 .. 3SB35 .. Plastic or metal ATEX 2690b actuator Contact block 3SB34 ..-0. Spring-loaded terminals or screw terminals Lampholder 3SB34 ..-1A Spring-loaded ATEX 2689b terminals or screw terminals LED 3SB39 01-1.A Rated voltage 24 V AC/DC, BA 9s base Components for actuators 1) Information for the implementation of current monitoring motor protection devices. Definition of the locked-rotor time tE: If the rotor of an explosion-protected induction motor of protection type "Increased Safety" EEx e stalls (locks) at operating temperature during runtime, the motor must be switched off, at the very latest, when either the rotor or the stator winding have reached their maximum temperature. The time that elapses until the rotor or stator winding has reached maximum temperature is called the locked-rotor time tE or tE time. The demands made on overload protective devices with regard to tE time: For trip units and relays with inverse-time delayed operation, tripping characteristics must be available at the operating site. The characteristic curves should show the tripping time for 3-pole loading, assuming a cold state and a room temperature of 20 °C, depending on at least a 3- to 8-fold setting current. The protective devices must comply with the specified tripping times with a permissible deviation of ± 20 %. The trip units and relays for machines with cage rotors must be selected such that the tripping times for 3-pole loading do not exceed the locked-rotor time tE specified on the type plate. For information on the tripping characteristics of our circuit breakers and overload relays, visit our web site at: http://www.siemens.com/lowvoltage/manuals ■ More information For more information about standards and approvals go to http://www.siemens.com/automation/support and select "Product Support". 20 If you have any questions concerning UL/CSA approvals, contact Technical Assistance, Tel.: +49 (0) 911 895 59 00. 20/28 Siemens LV 1 · 2008 Application up to a voltage of 26.4 V (LEDs) More information can be found on the Internet at: http://www.siemens.com/lowvoltage/atex Test certificates can be found at http://www.siemens.com/automation/support LV1_20.book Seite 29 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Quality management ■ Quality management The quality management system of our A&D division complies with the international standard EN ISO 9001. The products and systems described in this catalog are sold under application of a quality management system certified by DQS and TÜV Management Service GmbH in according to the ISO 9001. The certificates are recognized in all IQ Net countries. DQS Registered Certificate Nos.: Siemens AG Automation and Drives • Industrial Automation Systems Reg. No.: 001323 QM • Sensors and Communication Industrial Communication Reg. No.: 000656 QM. TÜV (German Technical Inspectorate) Registered Certificate No.: ■ Certificates An overview of the certificates available for SIMATIC NET products (CE, UL, CSA, FM, shipping authorizations) can be found on the Internet at: http://www.siemens.com/simatic-net Other certificates for SIMATIC products can be found on the Internet at: http://www.siemens.com/simatic These lists are continuously revised and updated. Data for products not yet included in the overview are continuously collected and prepared for subsequent editions. You can find certificates, approvals, verification test certificates and characteristic curves at: Support\Certificates Siemens AG Automation and Drives • Low-Voltage Controls Reg. No.: 12 100 16950 TMS. BVQI Registered Certificate No.: Siemens AG Automation and Drives • Electrical Installation Technology Reg. No.: 117779 20 or by going directly to the Link Box: Siemens LV 1 · 2008 20/29 LV1_20.book Seite 30 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Siemens contacts ■ Siemens contacts worldwide At http://www.siemens.com/automation/partner you can find details of Siemens contact partners worldwide responsible for particular technologies. You can obtain in most cases a contact partner for • Technical Support, • Spare parts/repairs, • Service, • Training, • Sales or • Consultation/engineering. You start by selecting a • Country, • Product or • Sector. 20 By further specifying the remaining criteria you will find exactly the right contact partner with his/her respective expertise. 20/30 Siemens LV 1 · 2008 LV1_20.book Seite 31 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Online services ■ A&D in the WWW A detailed knowledge of the range of products and services available is essential when planning and configuring automation systems. It goes without saying that this information must always be fully up-to-date. The Siemens Automation and Drives Group (A&D) has therefore built up a comprehensive range of information in the World Wide Web, which offers quick and easy access to all data required. Under the address http://www.siemens.com/automation you will find everything you need to know about products, systems and services. ■ Product Selection Using the Offline Mall of Automation and Drives Detailed information together with convenient interactive functions: The Offline Mall CA 01 covers more than 80,000 products and thus provides a full summary of the Siemens Automation and Drives product base. Here you will find everything that you need to solve tasks in the fields of automation, switchgear, installation and drives. All information is linked into a user interface which is easy to work with and intuitive. After selecting the product of your choice you can order at the press of a button, by fax or by online link. Information on the Offline Mall CA 01 can be found in the Internet under http://www.siemens.com/automation/ca01 or on CD-ROM or DVD. ■ Easy Shopping with the A&D Mall The A&D Mall is the virtual department store of Siemens AG in the Internet. Here you have access to a huge range of products presented in electronic catalogs in an informative and attractive way. Data transfer via EDIFACT allows the whole procedure from selection through ordering to tracking of the order to be carried out online via the Internet. Numerous functions are available to support you. For example, powerful search functions make it easy to find the required products, which can be immediately checked for availability. Customer-specific discounts and preparation of quotes can be carried out online as well as order tracking and tracing. Please visit the A&D Mall on the Internet under: 20 http://www.siemens.com/automation/mall Siemens LV 1 · 2008 20/31 LV1_20.book Seite 32 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Customer Support ■ Configuration and software engineering Support in configuring and developing with customer-oriented services from actual configuration to implementation of the automation project.2) ■ Technical Support .I Competent consulting in technical questions covering a wide range of customer-oriented services for all our products and systems. In the face of harsh competition you need optimum conditions to keep ahead all the time: A strong starting position. A sophisticated strategy and team for the necessary support - in every phase. Service & Support from Siemens provides this support with a complete range of different services for automation and drives. In every phase: from planning and startup to maintenance and upgrading. Tel.: +49 (0)180 50 50 222 Fax: +49 (0)180 50 50 223 (0.14 €/min from the German fixed network) Our specialists know when and where to act to keep the productivity and cost-effectiveness of your system running in top form. http://www.siemens.com/ automation/support-request ■ Online Support The comprehensive information system available round the clock via Internet ranging from Product Support and Service & Support services to Support Tools in the Shop. http://www.siemens.com/ automation/service&support ■ Technical Consulting Support in the planning and designing of your project from detailed actual-state analysis, target definition and consulting on product and system questions right to the creation of the automation solution.2) ■ Service on Site With Service On Site we offer services for startup and maintenance, essential for ensuring system availability. In Germany 0180 50 50 4442) (0.14 €/min from the German fixed network) ■ Repairs and Spare Parts In the operating phase of a machine or automation system we provide a comprehensive repair and spare parts service ensuring the highest degree of operating safety and reliability. In Germany 0180 50 50 4461) (0.14 €/min from the German fixed network) Technical Assistance Expert technical assistance1) for Low-voltage controls and electrical installation. ■ Optimization and Upgrading To enhance productivity and save costs in your project we offer high-quality services in optimization and upgrading.2) Tel.: +49 (9 11) 8 95-59 00 Fax: +49 (9 11) 8 95-59 07 E-Mail: technical-assistance @siemens.com 20 1) Contact: Technical assistance for product selection · Old/new coding · Competitor coding · Special versions · Special requirements · Sales promotion (Infoline). Your regional contacts for sales support (prices, discounts, delivery times). Technical Support for commissioning support and after-sales services. 20/32 Siemens LV 1 · 2008 2) For country-specific telephone numbers go to our Internet site at: http://www.siemens.com/automation/service&support LV1_20.book Seite 33 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Software licenses ■ Overview Software types Software requiring a license is categorized into types. The following software types have been defined: • Engineering software • Runtime software Factory license With the Factory License the user has the right to install and use the software at one permanent establishment only. The permanent establishment is defined by one address only.The number of hardware devices on which the software may be installed results from the order data or the Certificate of License (CoL). Engineering software This includes all software products for creating (engineering) user software, e.g. for configuring, programming, parameterizing, testing, commissioning or servicing. Data generated with engineering software and executable programs can be duplicated for your own use or for use by thirdparties free-of-charge. Certificate of license The Certificate of License (CoL) is the licensee's proof that the use of the software has been licensed by Siemens. A CoL is required for every type of use and must be kept in a safe place. License types Siemens Automation & Drives offers various types of software license: • Floating license • Single license • Rental license • Trial license Floating license The software may be installed for internal use on any number of devices by the licensee. Only the concurrent user is licensed. The concurrent user is the person using the program. Use begins when the software is started. A license is required for each concurrent user. Single license Unlike the floating license, a single license permits only one installation of the software. The type of use licensed is specified in the ordering data and in the Certificate of License (CoL). Types of use include for example per device, per axis, per channel, etc. One single license is required for each type of use defined. Rental license A rental license supports the "sporadic use" of engineering software. Once the license key has been installed, the software can be used for a specific number of hours (the operating hours do not have to be consecutive). One license is required for each installation of the software. Trial license A trial license supports "short-term use" of the software in a nonproductive context, e.g. for testing and evaluation purposes. It can be transferred to another license. Delivery versions Software is constantly being updated. The following delivery versions • PowerPack • Upgrade can be used to access updates. Existing bug fixes are supplied with the ServicePack version. PowerPack PowerPacks can be used to upgrade to more powerful software. The licensee receives a new license agreement and CoL (Certificate of License) with the PowerPack. This CoL, together with the CoL for the original product, proves that the new software is licensed. A separate PowerPack must be purchased for each original license of the software to be replaced. Upgrade An upgrade permits the use of a new version of the software on the condition that a license for a previous version of the product is already held. The licensee receives a new license agreement and CoL with the upgrade. This CoL, together with the CoL for the previous product, proves that the new version is licensed. A separate upgrade must be purchased for each original license of the software to be upgraded. ServicePack ServicePacks are used to debug existing products. ServicePacks may be duplicated for use as prescribed according to the number of existing original licenses. License key Siemens Automation & Drives supplies software products with and without license keys. The license key serves as an electronic license stamp and is also the "switch" for activating the software (floating license, rental license, etc.). The complete installation of software products requiring license keys includes the program to be licensed (the software) and the license key (which represents the license). Detailed explanations concerning license conditions can be found in the “Terms and Conditions of Siemens AG” or under http://www.siemens.com/automation/mall (A&D Mall Online-Help System) A&D/Software licenses/En 03.08.06 20 Runtime software This includes all software products required for plant/machine operation, e.g. operating system, basic system, system expansions, drivers, etc. The duplication of the runtime software and executable programs created with the runtime software for your own use or for use by third-parties is subject to a charge. You can find information about license fees according to use in the ordering data (e.g. in the catalog). Examples of categories of use include per CPU, per installation, per channel, per instance, per axis, per control loop, per variable, etc. Information about extended rights of use for parameterization/configuration tools supplied as integral components of the scope of delivery can be found in the readme file supplied with the relevant product(s). Downgrading The licensee is permitted to use the software or an earlier version/release of the software, provided that the licensee owns such a version/release and its use is technically feasible. Siemens LV 1 · 2008 20/33 LV1_20.book Seite 34 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Subject index Page Numerics 3RN1 thermistor motor protection Explosion protection (ATEX) for PTC sensors 8HP molded-plastic distribution systems 14/31 ... 14/32 7/5 7/71 ... 7/74 3RP15 timing relays in industrial enclosures 7/31 ... 7/36 3RP20 timing relays, 45 mm 7/37 ... 7/40 3RS17 interface converters 7/89 ... 7/91 3RT19 timing relays for mounting onto contactors 7/41 ... 7/42 3RV1 motor starter protectors Auxiliary trip units 5/20 Door-coupling 5/25 rotary operating mechansisms Mountable accessories 5/17 ... 5/20 Remote motorized operating mechanisms 5/25 3RV1 circuit breakers/motor starter 5/2, 5/4 ... 5/32 protectors 5/17 ... 5/32 Accessories 5/2, 5/13, 5/16 ... 5/18 Auxiliary switches Busbar accessories 5/21 ... 5/23 5/2, 5/21, 5/23, 5/29 Busbar adapters 5/2, 5/21 ... 5/23 Busbar systems Distance protection 5/2, 5/16 Door-coupling 5/2, 5/24 rotary operating mechanisms Enclosures 5/2, 5/30 ... 5/32 5/2, 5/31 Enclosures for flush mounting 5/2, 5/31 Enclosures for surface mounting Explosion protection (ATEX) 5/5 5/2, 5/30 ... 5/32 Front plates 5/2, 5/13 Fuse monitoring Infeed System 5/2 Insulated three-phase 5/2, 5/21 ... 5/23 busbar systems 5/2, 5/17, 5/19 Isolator modules Link modules 5/2, 5/28, 5/29 5/2, 5/6 ... 5/9 Motor protection - with overload relay function 5/2, 5/10 Mountable accessories 5/17 ... 5/20 5/26 ... 5/29 Mounting accessories Remote motorized 5/2, 5/24 operating mechanisms Rotary operating mechanisms 5/2, 5/24, 5/25 5/2, 5/17, 5/20 Shunt trip units Signaling switches 5/2, 5/17, 5/19 5/26, 5/27 Solder pin connections 5/2, 5/11 Starter combinations System protection 5/2, 5/14 5/26, 5/27 Terminals 5/2, 5/12, 5/15 Transformer protection Trip units 5/20 5/2, 5/17, 5/20 Undervoltage releases Voltage transformer circuit breakers 5/2, 5/16 7/75 ... 7/88 3TK28 safety relays with contactor relay enabling circuits 7/85, 7/86 with electronic enabling circuits 7/76 ... 7/79 with relay enabling circuits 7/80 ... 7/84 7/87, 7/88 with special functions 20 3UF18 current transformers for overload protection 20/34 Page Siemens LV 1 · 2008 7/19 14/10 8MC, 8MF cubicle systems 14/9 8PS busbar trunking systems Adapters Busbars for position switches Standard mounting rails Additional load modules 8US busbar systems 60 mm - Connection methods - Infeed 5/29 6/52 8/42 6/51, 6/52 3/109, 3/122, 3/126 2/61 Addressing units 14/48, 14/49 14/48, 14/49 8US busbar systems 40 mm - Accessories - Busbar adapters - Connection methods - Device holders - Infeed 60 mm - Accessories - Bar-mounting fuse bases - Base assemblies - Busbar adapters - Device holders 14/33 ... 14/56 14/38 ... 14/38 ... 14/50 14/50 ... ... 14/42 14/41 14/37 14/41 14/37 14/56 14/55 14/44 14/54 14/54 A Accessories and spare parts for contactors and contactor relays 3/97 ... 3/131 - Additional load modules 3/109, 3/122, 3/126 - Arc chutes 3/118, 3/121, 3/127 ... 3/130 - Auxiliary switch blocks 3/100 ... 3/102, 3/103 ... 3/105, 3/120, 3/121, 3/125,3/127 ... 3/130 - Auxiliary terminals 3/110 - Box terminals 3/112 - Connection modules 3/110 - Contacts 3/127 ... 3/130 - Coupling links 3/110, 3/124 - Covers 3/112, 3/120, 3/130 - EMC interference modules 3/109 - Insulation stop for contactors 3/113 - LED modules for indicating contactor operation 3/110 - Links for paralleling 3/111, 3/120, 3/123 - Locking devices 3/130 - Magnetic coils 3/114, 3/115, 3/121, 3/127 ... 3/130 - Mechanical latching blocks 3/106 - OFF-delay devices 3/106, 3/121, 3/125 - ON-delay devices 3/124 - Plug-in bases 3/122, 3/126 - Pneumatic delay blocks 3/106 - Screw adapters 3/111 - Solder pin adapters 3/110, 3/111 - Solid-state time-delay blocks 3/106 - Surge suppressors 3/107, 3/108, 3/119, 3/122, 3/124, 3/126 - Withdrawable coils 3/116, 3/117 Acoustic signal transformers for acoustic signaling devices Actuators for position switches Page 9/77 8/48, 8/49, 8/54, 8/55 Adapter sleeve fitters for NEOZED 19/63 Adapter sleeves for DIAZED NEOZED 19/69 19/63 Air circuit breakers/ non-automatic air circuit breakers 15/1 ... 15/49 ALPHA 630-DIN floor-mounted distribution boards 14/13 ALPHA FIX terminal blocks Accessories 14/28 ... 14/23, Combination plug-in terminals Insulation displacement connection Plug-in connection 14/25, 14/14 ... Screw connection 14/18 ... Spring-type connections 14/30 14/24 14/27 14/26 14/17 14/22 19/156 Ammeter selector switches Analyzers 2/62 ... 2/64 ... 20/28 Approvals 20/11 Arc chutes for contactors 3/118, 3/121, 3/127 ... 3/130 2/9 ... 2/66 AS-Interface ASIsafe 2/13 ... 2/17 9/101 Cable-operated switches 2/10 Communication overview EMERGENCY-STOP mushroom pushbuttons 9/63, 9/95 Enclosures for pushbutton units 9/94 ... 9/96 and indicator lights 9/63 F adapters 2/18 ... 2/21 Masters Power supply units 2/58 2/26 ... 2/32 Routers 9/105, 9/108 Signaling columns 2/33 ... 2/57, 9/96 Slaves Specification 2/11, 2/12 System components and accessories 2/65, 2/66 - Accessories - Addressing units 2/61 - Analyzers 2/62 ... 2/64 - Extension plugs 2/60 Transmission media - Shaped cables 2/59 2/9 Transmission technology ASIsafe Safety modules Safety monitors 2/16, 2/17 2/14 ATEX 3RN1 thermistor motor protection 3RV1 motor starter protectors Overload relays 5/38, 5/47, SIMOCODE 3UF motor management and control devices 7/5 5/5 5/52 7/5 10/2, 10/3, 10/5, Autotransformers 10/47 ... 10/50, 10/61 ... 10/63, 10/84, 10/85 10/3, 10/86, 10/87 for matching purposes Auxiliary switch blocks for contactors and contactor relays - Laterally mountable 3/103, 3/127 ... 3/130 - Snap-on 3/100 ... 3/102, 3/121, 3/125 - Solid-state time-delay 3/104, 3/105, 3/120 LV1_20.book Seite 35 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Subject index Auxiliary switches for 3RV1 motor starter protectors 5/2, 5/13, 5/16 ... 5/18 15/22, 15/37, 16/38, for circuit breakers 16/40 ... 16/42, 16/76 Auxiliary switches for Cylindrical fuses LV HRC fuse switch disconnectors Residual current protective devices SR60 busbar systems 19/73 19/106 19/46 19/131 3/110 Auxiliary terminals Auxiliary trip units 5/20 for 3RV1 motro starter protectors 15/22, 15/37, 16/38, for circuit breakers 16/40 ... 16/41, 16/76 B Base plates for contactor assemblies 3/37, 3/47 Blanking plugs for pushbutton units and indicator lights 9/79 5/51 Box terminal blocks for overload relays Box terminals 3/112 Breaker blocking covers for miniature circuit breakers 19/36 Busbar accessories for 3RV1 motor starter protectors 5/21 ... 5/23 16/68 Busbar adapter systems 6/52 Busbar adapters for 3RV1 circuit breakers/motor starter protectors 5/2, 5/21, 5/23, 5/29 Busbar adapters for main miniature circuit breakers (SHU) 19/36 19/125 Busbar supports Busbar systems for 3RV1 circuit breakers/motor starter protectors 5/2, 5/21, 5/23 Busbars 19/63 Busbar adapters for LV HRC fuse switch disconnectors 19/105 Bus-mounting bases SR60 DIAZED SR60 NEOZED 19/130 19/129 Bus-mounting disconnectors SR60 NEOZED 19/131 19/131 Cable-operated switches Capacitor contactors Caps for DIAZED Combination plug-in terminals ... 6/65 Configuring, visualizing and controlling 18/1 with SIMATIC and SENTRON ... 18/7 Connecting cables 5/49 Connection for LOGO! 2/57 Connection modules for contactors 3/58 19/69 2/52, 2/53 6/63 Compact starters 400 V AC 5/50, 5/56 ... 9/101 14/23, 14/24 Communication-capable circuit breakers 15/24, 15/40, 16/74 9/16, 9/76 9/3, 9/98 3/37 Coil repeat terminals Connection methods for circuit breakers C Cable releases for RESET Circuit breakers Air 15/1 ... 15/49 Auxiliary switches 15/22,15/3716/38,16/40 ... 16/42, 16/76 Auxiliary trip units 15/22, 15/37, 16/38, 16/40 ... 16/41, 16/76 Communication-capable 15/24, 15/40, 16/74 15/26 ... 15/27, Connection methods for 15/42 ... 15/43 15/44 Conversion sets Fixed mounting 15/6 ... 15/9, 15/14 ... 15/17, 15/47, 16/8 ... 16/38, 16/75 16/10 ... 16/11, Generator protection 16/14 ... 16/15, 16/21, 16/28 ... 16/29, 16/37 Guide frames 15/29 ... 15/30, 15/49 Interlocks 16/62 ... 16/67 16/1 ... 16/76 Molded case Motor protection 16/10 ... 16/11, 16/14 ... 16/17, 16/21 Operating mechanisms 15/22, 15/24, 15/37, 16/39, 16/43 ... 16/48, 16/76 16/49 ... 16/54 Plug-in versions 16/55 RCD modules Shunt trip units 15/22, 15/37 Shunt trip units for 16/38, 16/40 ... 16/41,16/76 16/12 ... 16/13 Starter combinations System protection 16/8 ... 16/11, 16/14 ... 16/17, 16/21 ... 16/34, 16/36 ... 16/37, 16/75 Undervoltage trip units 15/22, 15/37,16/38, 16/40 ... 16/41, 16/76 with electronic trip unit 15/6 ... 15/21, 15/31, 16/8 ... 16/37, 16/75 15/45 Withdrawable bridging units 15/45 Withdrawable grounding units Withdrawable short-circuits 15/45 15/10 ... 15/13, Withdrawable versions 15/18 ... 15/21, 15/48, 16/49 ... 16/54 16/12 ... 16/13, without electronic trip unit 16/28 ... 16/29 Communications modules Bus-mounting fuse bases SR60 LV HRC Buttons Page 15/26 ... 15/27, 15/42 ... 15/43 for fixed-mounted circuit breakers 16/56 ... 16/61, 16/76 Connectors mechanical 3/110 3/39 Contact blocks 9/29 for joystick switches for magnetically operated switches 8/86 8/43 for position switches 9/9, 9/10, 9/59 ... 9/62, for pushbuttons 9/88, 9/89 Page Contactor assemblies Contactor assemblies for wye-delta starting 3/40 ... 3/47 - Complete units 3/40 ... 3/46 - Components for customer assembly 3/47 Reversing contactor assemblies 3/32 ... 3/39, 3/48 - Complete units 3/32 ... 3/36, 3/48 - Components for customer assembly 3/37 ... 3/39 Wye-delta starting 3/49 - Complete units 3/49 Contactor assemblies for wye-delta starting 3/40 ... 3/47 3/69 ... 3/78 Contactor relays Coupling relays for switching auxiliary circuits 3/78 3/72 Latched 3/70 with auxiliary switch block Contactors 3/50 ... for special applications - Capacitor contactors - for switching DC voltage 3/66 ... - for switching resistive loads 3/50 ... - with extended operating range, for railway applications 3/59 ... for switching motors 3/5 ... 3/31, 3/61 ... - Vacuum contactors 3/26 ... - with auxiliary switch block 3/15 ... 3/21, - with DC solenoid system Contacts for contactors 3/127 3/65 3/64 3/28 3/31 3/29 ... 3/130 7/1 Control devices 3/68 3/58 3/68 3/54 ... 7/91 10/2,10/3,10/5 ... 10/19, Control transformers 10/24 ... 10/41, 10/4710/48, 10/57 ... 10/59, 10/61, 10/62 Conversion sets Fixed-mounted circuit breakers to withdrawable circuit breakers 15/44 Converter transformers 10/49,10/50,10/63, 10/84, 10/85 Converters 4/26 9/27, 9/28 Coordinate switches 2/54 Counter modules 3/110, 3/124 Coupling links Coupling relays for switching auxiliary circuits 3/78 3/79 ... 3/81 for switching motors 3/82 ... 3/87 Narrow design - Relay couplers 3/82, 3/83 - Relay couplers with plug-in connection 3/84, 3/85 - Semiconductor couplers 3/86, 3/87 with industrial housing - Relay couplers 3/88 Covers 3/112, 3/120, 3/130, 15/25, 15/32, 15/38 for position switches 8/43 5/26, 5/51, 5/56 for terminals 19/130 SR60 DIAZED SR60 NEOZED 19/130 Covers for 19/69 DIAZED Residual current protective devices19/27, 19/57 Covers for time counters 19/160 Cubicle air-conditioning 14/12 CubicleBUS modules 15/41 5/49 Current measuring modules 7/49, 7/50 Current monitoring Current transformers 14/68 Siemens LV 1 · 2008 ... 14/70 20/35 20 Page LV1_20.book Seite 36 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Subject index Page D DC current Non-automatic air circuit breakers for 15/47 ... 15/49 3/106 Delay blocks, pneumatic DIAZED Adapter sleeves Caps Gauge screws SR60 bus-mounting bases SR60 covers SR60 gauge rings 19/69 19/69 19/69 19/130 19/130 19/130 Dimensioning with SIMARIS design 18/1 ... 18/3 6/2, 6/32 ... 6/39 Direct-on-line starters Encapsulated 6/131 for busbar systems 6/36 ... 6/39, 6/70 ... 6/71 for snapping onto standard mounting rails 6/32 ... 6/35 or for screw mounting 5/2, 5/16 Distance protection Door-coupling rotary operating mechanisms for 3RV1 motor starter protectors 5/25 Door-coupling rotary operating mechanisms 14/57 ... 14/67 for 3RV1 circuit breakers/motor starter protectors 5/2, 5/24 14/62 ... 14/65 for circuit breakers for switch disconnectors 14/58 ... 14/61 14/66 Individual parts Operating mechanisms for fixed mounting 14/67 Page Page Enclosures for Residual current protective devices 19/27, 19/57 Fuseless load feeders 6/2, 6/31 ... 6/57 Assembly kits 6/51 - for reversing duty 6/51 Coil repeat terminals 6/50 Connection modules for contactors Direct-on-line starters - for busbar systems 6/36 ... 6/39 - for snapping onto standard mounting rail or for screw mounting 6/32 ... 6/35 6/54 ... 6/57 Infeed system 6/50 Link modules Mechanical interlocks 6/51 Reversing starters 6/44 ... 6/47 - for busbar systems - for snapping onto standard mounting rail or for screw mounting 6/40 ... 6/44 6/51 Standard mounting rail adapters Surge suppressors 6/49 6/50 Wiring kits Enclosures for flush mounting for 3RV1 circuit breakers/ motor starter 5/2, 5/31 protectors Enclosures for surface mounting for 3RV1 motor starter protectors 5/2, 5/31 19/32 End caps for busbars ET 200S Safety motor starters 6/3, 6/103 ... 6/113 ET 200S Failsafe motor starters 6/104 ... 6/105 Safety modules local 6/106 ... 6/110 6/111 ... 6/113 Safety modules PROFIsafe ETU electronic trip units 15/6 ... 15/21, 15/31, 16/8 ... 16/37, 16/75 5/48 Evaluation modules Explosion protection (ATEX) 3RN1 thermistor motor protection 3RV1 motor starter protectors 5/38, 5/47, Overload relays SIMOCODE 3UF motor management and control devices Extension plugs 7/5 5/5 5/52 7/5 Gauge rings SR60 DIAZED 19/130 2/60 Gauge screws for DIAZED 19/69 Generator protection F 3/47, 19/38 Feeder terminals Fixed mounting Circuit breakers 15/6 ... 15/9, 15/14 ... 15/17, 15/47 16/8 Fixed-mounted circuit breakers ... 16/38, 16/75 E ECOFAST 2/67 ... 2/69 12/4 ECOFAST ES ECOFAST System 2/67 ... 2/69 E-counters for 3/4 conductor connection 19/153, 19/155 for active and reactive energy 19/153, 19/155 for active energy 19/153, 19/155 Electronic trip units 15/6 ... 15/21, 15/31, 16/8 ... 16/37, 16/75 EMC interference modules for contactors 3/109 EMERGENCY-STOP door-coupling rotary operating mechanisms for 3RV1 motor starter protectors 5/25 EMERGENCY-STOP mushroom buttons for 3RV1 motor starter protectors EMERGENCY-STOP mushroom pushbuttons 9/5, 9/7, 9/22, 9/35, 9/39, 9/43, 9/46, 9/57, 9/84, 9/85, 9/95 Encapsulated starters Direct-on-line starters Reversing starters 6/3, 6/130 Encapsulated transformers 10/2, 10/51 ... 6/133 6/131 6/132 ... 10/53 20 Enclosures for 3RV1 motor starter protectors 5/2, 5/30 ... 5/32 for pushbutton units and indicator lights 9/83 ... 9/95 for transformers 10/48, 10/50, 10/62, 10/84, 10/85 20/36 Siemens LV 1 · 2008 ... 16/61, 16/76 Connection methods for 16/56 Fixing parts for Miniature circuit breakers Residual current protective devices 19/26 19/57 Floor-mounted distribution boards 14/13 Front plates for 3RV1 motor starter protectors 5/2,5/30 ... 5/32 4/5, 4/21 Function modules Converters Heating current monitoring Load monitoring Power control regulators Power controllers ... 4/30 4/26 4/28 4/27 4/29 4/30 19/63 5/2, 5/13 Fuse monitoring Fuse switch disconnectors 17/47 ... 17/74 17/70, 17/71 1-pole and 3-pole switchable Assembly kits for distribution systems 17/57 ... 17/59 for extended technical requirements 17/60, 17/61 for extended technical requirements with fuse monitoring 17/62 ... 17/69 17/48 ... 17/50 for power distribution for power distribution with fuse monitoring 17/51 ... 17/53 Fused load feeders 16/10 ... 16/11, 16/14 ... 16/15, 16/21, 16/28 ... 16/29, 16/37 2/55 Ground-fault detection modules Guide frames for circuit breakers 15/29 ... 15/30, 15/49 H Handle couplers for Residual current protective devices 19/54 Handle locking devices for Miniature circuit breakers 19/26 4/28 Heating current monitoring Hinge switches 8/2, 8/56 ... 8/58, 8/75, 8/76 5/48 Function expansion modules Fuse bases NEOZED 5/32 G 6/2, 6/62 I I/O modules 2/48 ... for operation in the control cabinet 2/51 - F90 modules 2/51 - Flat modules 2/51 - SlimLine 2/49, 2/50 2/33 ... 2/47 for operation in the field - Analog 2/45 ... 2/47 - Digital 2/34 ... 2/44 Incandescent lamps for pushbutton units and indicator lights 9/16, 9/76 9/2, 9/4, 9/8, 9/25, 9/26, 9/36, 9/39, 9/43, 9/48, 9/58 5/32 for 3RV1 motor starter protectors Indicator lights Infeed system 5/2, 6/2, 6/54 Inscription labels for enclosures Inscription labels for Miniature circuit breakers Residual current protective devices ... 6/57 5/57 9/90, 9/91 19/26 19/57 LV1_20.book Seite 37 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Subject index Page Insert labels for pushbutton units and 9/11 ... 9/14, 9/67 indicator lights ... 9/69 Installation kits for contactor assemblies 3/38, 3/47 Insulated three-phase busbar systems for 3RV1 circuit breakers/motor starter protectors 5/2,5/21 ... 5/23 Insulation monitoring for ungrounded AC networks for ungrounded DC voltage networks 7/56 7/57 3/113 Insulation stop for contactors 9/3, 9/110 Integrated signal lamps 15/25, 15/33 16/62 ... 16/67 3/37 Interlocks for circuit breakers Mechanical 10/2, 10/3, 10/5, Isolating transformers 10/24 ... 10/48, 10/57 ... 10/62 10/2, 10/54 for supply of medical premises 10/2, 10/53 Resin-enclosed 5/2, 5/17, 5/19 Isolator modules Locking devices for Residual current protective devices 19/47 Locking devices for contactors 3/130 Locks for rotary buttons and switches 9/6, 9/8, 9/23,9/24,9/33, 9/34, 9/42, 9/47, 9/55, 9/56 Locks for Miniature circuit breakers Residual current protective devices 19/26 19/47 LOGO! AS-Interface connections AS-Interface connections for LOGO! CM EIB/KNX communications modules Contact 7/21, Modular basic variants 7/25, Modular expansion modules Modular pure variants 7/23, Software 7/20 LOGO! logic modules 2/57 7/28 7/27 7/29 7/22 7/26 7/24 7/30 ... 7/30 11/2, 11/11 LOGO!Power LV HRC SR60 bus-mounting fuse bases 19/131 K 2/16, 2/17 K45F LS (light sensor) 9/32 Knobs for rotary buttons and switches Labels 4/4 Lampholders for pushbutton units and indicator lights 9/9, 9/10, 9/59 ... 9/62,9/88, 9/89 9/16, 9/76 Lamps 3/72 Latched contactor relays Latching blocks mechanical 3/106 Leakage current measurement units 19/46 LED modules for indicating contactor operation 3/110 LEDs for pushbutton units and indicator lights 9/16, 9/76 Lenses for indicator lights 9/16, 9/75 Level monitoring Level monitoring relays 7/58, 7/59 7/60 Level monitoring sensors 7/43 Line monitoring Link modules for 3RV1 motor starter protectors ... 7/46 5/29, 6/52 5/2, 5/28 Link rails Single-pole Two-pole Links for paralleling M Magnetic coils for contactors 3/114, 3/115, 3/121, 3/127 ... 3/130 Magnetically operated switches 8/3, 8/85, 8/86 L 19/38 19/38 3/47, 3/111, 3/120, 3/123 Load feeders Fuseless Modules - AS-Interface with safety integrated 6/31 6/10, 6/68 6/2, 6/58 ... 4/4 6/57 ... 6/69 ... 6/62 Load monitoring 4/27 Locking devices 15/26, 15/32 Main and EMERGENCY-STOP switches 17/24, 17/25 Distribution board mounting 17/26, 17/27 Molded-plastic enclosures Main circuit connections 15/27, 15/42 ... 15/43 Main control and EMERGENCY-STOP switches 17/28 ... 17/31 Accessories 17/20 ... 17/23 Floor mounting Front mounting 17/15 ... 17/19 Mains transformers 10/5 10/2, 10/3, ... 10/48, 10/57 ... 10/62 Male connectors for lightning and overvoltage protection devices Masters CP 142-2 CP 243-2 CP 343-2 CP 343-2 P 19/140 2/18 2/19 2/20 2/21 10/3, 10/49, 10/50, Matching transformers 10/63 ... 10/73, 10/86, 10/87 with cURus approval 10/3, 10/74 ... 10/83 10/3, 10/84, 10/85 with selectable voltages Measuring devices Multicounters Multimeters Time counters Measuring selector switches 5/50, 5/56 Mechanical RESET 15/26, 15/33 Locking mechanisms Page 19/147 19/145, 19/150 19/160 19/156 Miniature circuit breakers AC/DC product range High-capacity product range High-current product range 19/13 19/5 ... 19/18 19/12, 19/14 3/96 Miniature contactors/Power relays 16/1 Molded case circuit breakers ... 16/76 Molded-plastic enclosures for 3RV1 motor starter protectors 5/30 ... 5/32 Molded-plastic enclosures for Residual current protective devices 19/27,19/57 Momentary contact foot switches, 9/3, 9/102, 9/103 foot switches 7/1 Monitoring devices ... 7/91 Monitoring relays for electrical and additional measurements Current monitoring 7/49, 7/56, Insulation monitoring 7/58 ... Level monitoring Level monitoring sensors 7/43 ... Line monitoring Power factor and 7/51, active current monitoring 7/53 ... Residual current monitoring 7/61, Speed monitoring Summation current transformers 7/47, Voltage monitoring Monitoring units for magnetically operated switches 7/50 7/57 7/60 7/60 7/46 7/52 7/55 7/62 7/55 7/48 8/86 Motor management and control devices 7/6 SIMOCODE pro 3UF7 ... 7/14 5/2, 5/3, 5/6 ... 5/9, Motor protection 16/10 ... 16/11,16/14 ... 16/17, 16/21 - with overload relay function 5/2, 5/10 Motor protection and control devices SIMOCODE-DP 3UF5 7/15 Motor starters 24 V DC ET 200pro - High-Feature - Isolator modules - Safety modules local - Standard ET 200S - High-Feature - Interface modules - Power modules - Solid-state modules - Standard - Terminal modules ... 7/18 12/2, 12/3 Motor Starter ES 6/66 ... 6/67 6/3, 6/114 ... 6/128 6/115 6/116 6/117 6/115 6/3, 6/75 ... 6/102 6/79 6/87 ... 6/102 6/82 6/87 ... 6/102 6/78 6/83 ... 6/86 Motor starters and load feeders IP20 IP65/67 6/68 6/63 ... 6/74 ... 6/67 Motor starters and soft starters 6/3, 6/63 ... 6/74 AS-Interface ECOFAST 6/3, 6/129 Mechanical connectors for contactor assemblies 3/39 Mechanical interlocks for contactor assemblies Mountable accessories for 3RV1 motor starter protectors 5/17 ... 5/20 3/37 Mounting accessories for 3RV1 motor starter protectors 5/26 ... 5/29 Mechanical latching blocks for contactors and contactor relays 3/106 20 3/113, 6/9 Inscription labels, blank Page Siemens LV 1 · 2008 20/37 LV1_20.book Seite 38 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Subject index Multicounters Page Page 19/147 Position switches 8/2 ... 8/76 8/18, 8/21, 8/38, 8/42, 8/43 Accessories Actuators 8/48, 8/54 8/64 ... 8/76 AS-Interface 8/43 Contact blocks Explosion protection (ATEX) 8/60 ... 8/63 Hinge switches 8/2, 8/56 ... 8/58, 8/75, 8/76 8/2, 8/22 ... 8/39 Metal enclosures Open-type 8/40, 8/41 8/2, 8/8 ... 8/15 Plastic enclosures 8/43 Spare parts with separate actuator 8/3, 8/70, 8/71 8/3, 8/73, 8/74 with tumbler 8/44 ... 8/49 wth separate actuator wth tumbler 8/50 ... 8/55 19/145, 19/150 Multimeters Mushroom pushbuttons and switches 9/22, 9/31, 9/46, 9/50 N Name plates for EMERGENCY-STOP mushroom pushbuttons for joystick switches for pushbutton units and indicator lights 9/17, 9/80 9/29 9/15, 9/70 ... 9/74 NEOZED Adapter sleeve fitters 19/63 19/63 Adapter sleeves 19/63 Busbar adapters Fuse bases 19/60 ... 19/63 19/63 Retaining springs 19/62 Screw caps SR60 bus-mounting bases 19/129 SR60 bus-mounting switch disconnectors 19/130 SR60 covers 19/130 Non-automatic air circuit breakers 15/1 ... 15/2, Air 15/6 ... 15/20, 15/47 ... 15/48 15/47 ... 15/49 DC current 16/12 ... 16/13, Molded case 16/28 ... 16/29 Non-automatic molded case circuit breakers 16/12 ... 16/13, 16/28 ... 16/29 Non-stabilized power supplies 11/2, 11/4 ... 11/8 Filtered Single-phase 11/2, 11/4, 11/6, 11/9, 11/11 ... 11/14 11/2, 11/7, 11/8, 11/10, 11/13 Three-phase 11/2, 11/9, 11/10 Unfiltered O 3/106, 3/121, 3/125 OFF-delay devices 3/124 ON-delay devices for contactor relays Operating mechanisms for circuit breakers 15/22, 15/24,15/37, 16/39, 16/43 ... 16/48, 16/76 8/18, 8/21, 8/37, 8/38 for position switches 5/3, 5/33 ... 5/57 Overload relays Explosion protection (ATEX) 5/38, 5/47, 5/52 2/55, 2/56 Overvoltage protection modules P 19/26 Pillar-type variable-ratio transformers 10/2, 10/3 3/122, 3/126 Plug-in bases Plug-in connections for position switches Plug-in relays Relay couplers 20 Plug-in versions Circuit breakers Power control regulators 4/29 Power controllers 4/30 Power distribution boards 14/7 Power factor and active current monitoring 7/51, 7/52 13/2 Power Management System 3/89 ... 3/92, 3/93 ... 3/95 16/49 Siemens LV 1 · 2008 ... 16/54 3/106 ... 13/3, Power modules for ET 200S motor starters 6/82 Power relays/Miniature contactors 3/96 11/1 ... 11/16 Power supplies Filtered 11/2, 11/4 ... 11/8 11/2, 11/11 LOGO!Power 11/2, 11/4 ... 11/10 Non-stabilized Single-phase 11/4, 11/6, 11/9,11/11 ... 11/14 11/11 ... 11/16 SITOP 11/14 SITOP add-on modules SITOP battery modules 11/16 11/14 SITOP buffer modules 11/15 SITOP DC UPS modules 11/2, 11/13 SITOP modular SITOP redundancy modules 11/14 11/14 SITOP select diagnostics modules 11/14 SITOP signaling modules SITOP smart 11/2, 11/12 11/2, 11/15, 11/16 SITOP uninterruptible 11/13, 11/14 SITOP, modular Stabilized, SITOP 11/11 ... 11/16 11/7, 11/8, 11/10, 11/13 Three-phase 11/2, 11/9, 11/10 Unfiltered 2/58 Power supply units AS-Interface 10/2, 10/3, 10/49, 10/50, 10/63 ... 10/85 Enclosures 10/84, 10/85 10/2, 10/3, with selectable voltages 10/49, 10/50, 10/84, 10/85 Power transformers 2/74 ... 2/83, 15/41 Protection equipment Protective caps for pushbuttons 5/1 ... 5/57 9/17, 9/78 Protective collars for pushbutton units and indicator lights Protective devices with device holder Pneumatic delay blocks for contactors and contactor relays 20/38 8/42 9/9, 9/10 9/6 9/8 9/11 ... 9/15 9/9, 9/10 9/18 ... 9/96 9/75 ... 9/82 9/93 9/40 ... 9/43, 9/49 ... 9/57 - AS-Interface enclosures 9/94 ... 9/96 - Complete units 9/20 ... 9/26, 9/38, 9/39, 9/44 ... 9/48 - Contact blocks 9/59 ... 9/62 - Coordinate switches 9/27, 9/28 - Enclosures 9/3, 9/83 ... 9/93 - Indicators 9/36, 9/43, 9/58 - Inscriptions 9/65 ... 9/74, 9/90 ... 9/92 - Lampholders 9/59 ... 9/62 - Twin pushbuttons 9/36, 9/37 - Contact blocks - Indicator lights - Indicators - Inscriptions - Lampholders Nominal diameter 22 mm - Accessories and spare parts - Accessories for enclosures - Actuators 9/30 ... 9/37, 8/2 Position switches, open-type PROFIBUS Padlocks Page 9/79 15/31 Pushbutton units and 9/2, 9/4 ... 9/96 indicator lights 9/4 ... 9/17 Nominal diameter 16 mm - Accessories and spare parts 9/16, 9/17 - Actuators 9/7, 9/8 - Complete units 9/5, 9/6 9/2, 9/4, 9/5, 9/7, Pushbuttons and switches 9/18, 9/20, 9/21, 9/30, 9/38, 9/40, 9/44, 9/45, 9/49 Push-in lugs for 3RV1 motor starter protectors for overload relays 5/27 5/51 R Rated current modules 15/23, 15/31 Rating plugs 15/23, 15/31 16/55 RCD modules for circuit breakers Relay couplers 3/82, 3/83, 3/88 ... 3/92 Relays Analogically adjustable, 7/63 ... 7/65 for 1 sensor Digitally adjustable 7/69, 7/70 for up to 3 sensors Digitally adjustable, for 1 sensor 7/66 ... 7/68 Remote motorized operating mechanisms for 3RV1 motor starter 5/2, 5/24, 5/25 protectors 5/56 Remote RESET Remote-controlled operating mechanisms for 19/46 Residual current protective devices RESET Cable releases Mechanical Remote 5/50, 5/56 5/50, 5/56 5/56 Residual current monitoring Summation current transformers 7/55 Residual current protective devices 19/39 ... 19/57 19/46 Auxiliary switches Enclosures 19/27, 19/57 19/46 Leakage current measurement units 19/47 Locks Molded-plastic enclosures 19/27, 19/57 Remote-controlled operating mechanisms 19/46 Residual-current monitoring Residual-current monitoring relays 7/53, 7/54 Retaining springs for NEOZED Reversing contactor assemblies 19/63 3/32 ... 3/36, 3/48 LV1_20.book Seite 39 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Subject index Page Reversing starters 6/2, 6/40 ... 6/47 6/132 Encapsulated for busbar systems 6/44 ... 6/47, 6/72 ... 6/74 for snapping onto standard mounting rails 6/40 ... 6/44 or for screw mounting Single-phase transformers 10/2, 10/5 ... 10/56 10/2, 10/5, 10/47 ... 10/50 AutoControl 10/2, 10/5 ... 10/19, 10/24 ... 10/41, 10/47, 10/48 10/49, 10/50 Converter Enclosed 10/2, 10/51 ... 10/53 10/48, 10/50 Enclosures 10/2, 10/5, 10/24 ... 10/48 Isolating - for supply of medical premises 10/2, 10/54 - Resin-enclosed 10/2, 10/53 10/2, 10/5 ... 10/48 Mains Matching 10/49, 10/50 10/2 Pillar-type 10/2, 10/49, 10/50 Power Safety 10/2, 10/5 ... 10/23, 10/47, 10/48 - Resin-enclosed 10/2, 10/51, 10/52 10/2 Toroidal-core Variable-ratio 10/2 Voltage regulators 10/2, 10/56 - Magnetic type - Transformer-type 10/2, 10/55 10/2, 10/5, with selectable voltages 10/47 ... 10/50 wth selectable voltages 10/55 Rotary operating mechanisms for 3RV1 circuit breakers/motor starter protec5/2, 5/24 5/25 tors Routers DP/AS-i F-Link DP/AS-i LINK Advanced DP/AS-Interface Link 20E IE/AS-i LINK PN IO 2/22 2/29, 2/30 2/31, 2/32 2/26 ... 2/28 S Safety modules 2/16, 2/17 Safety monitors 2/14 Safety transformers 10/2, 10/3, 10/5 ... 10/23, 10/47, 10/48, 10/57,10/61, 10/62 10/2, 10/51, 10/52 Resin-enclosed 19/142, 19/143 SCHUKO socket outlets Screw adapters for contactors 3/111 Screw caps for NEOZED 19/62 5/29, 5/51, 5/57 Screwdrivers 5/51 Sealable covers Selector switches for rotary buttons and switches 9/6, 9/7, 9/23 9/24, 9/41, 9/47,9/51,9/52, 9/53, 9/54 Selector switches for Ammeters Voltmeters 19/156 19/156 3/86, 3/87 Semiconductor couplers Semiconductor-motor contactors 3-phase, 3RF24 4/32 ... 4/33 2/59 Shaped cables Shunt trip units for 3RV1 motor starter protectors 5/2, 5/17, 5/20 15/22, 15/37, 16/38, for circuit breakers 16/40 ... 16/41, 16/76 14/11 SICUBE system cubicles Signaling columns 9/3, 9/104 Signaling switches for 3RV1 motor starter protectors ... 9/109 5/2, 5/17,5/19 SIMARIS design SIMATIC powercontrol SIMATIC powercost SIMOCODE -DP 3UF5 pro 3UF7 7/15 7/6 2/84 2/70 ... 2/86 ... 2/73 11/2, 11/11 ... 11/16 SITOP 11/14 Add-on modules Battery modules 11/16 11/14 Buffer modules 11/15, 11/16 DC UPS modules LOGO!Power 11/2, 11/11 11/2, 11/13 Modular 11/14 Redundancy modules Signaling modules 11/14 11/14 SITOP select diagnostics modules Smart 11/2, 11/12 11/2, 11/15, 11/16 Uninterruptible SITOP add-on modules 11/14 SITOP battery modules 11/16 SITOP buffer modules 11/14 SITOP DC UPS modules 11/15 11/2 SITOP modular SITOP modular power supplies 11/2, 11/13 18/3 SITOP redundancy modules 11/14 18/4 SITOP select diagnostics modules 11/14 18/6 SITOP signaling modules 11/14 ... 7/18 ... 7/14 SIMOCODE 3UF motor management and control devices, explosion protection (ATEX) 7/5 SIMOCODE ES SIRIUS Modular system Safety Integrated 12/5, 12/6 Single-phase power supplies 11/2, 11/4, 11/6 Filtered LOGO!Power 11/2, 11/11 11/2, 11/4 Non-stabilized 11/2, 11/13 SITOP modular SITOP smart 11/2, 11/12 Stabilized 11/2, 11/11 ... 11/13 - SITOP Unfiltered 11/2, 11/9 11/2, SITOP uninterruptible power supplies 11/15, 11/16 SIVACON motor control centers Slaves Connections for LOGO! I/O modules - for operation in the control cabinet 2/48 ... - for operation in the field 2/33 ... Modules with special functions - Counter modules - Ground-fault detection modules - Overvoltage protection modules 2/55, Special integrated solutions 2/52, - Communications modules User modules 14/7 2/57 2/51 2/47 2/54 2/55 2/56 2/53 2/44 Page Socket outlets 19/142, 19/143 Soft Starter ES 12/7,12/8 6/2, 6/4 ... 6/30 Soft starters 6/20 ... 6/30 for High-Feature applications - Box terminal blocks 6/26 - Covers 6/27 - Ext. display and operator modules 6/26, 6/27 - Fans 6/27 - Inline circuit 6/21 - Inside-delta circuit 6/24 - PC cables 6/26 - PROFIBUS communications modules 6/26 - Software 6/26 6/5 ... 6/19 for standard applications - Box terminal blocks 6/16 - Covers 6/8, 6/16 - Fans 6/8, 6/17 - Link modules 6/9 - Modules for RESET 6/16 - Push-in lugs 6/8 - Sealable covers 6/8 18/1 Software for power distribution ... 18/7 Solder pin adapters for contactors 3/110, 3/111 Solder pin connections for 3RV1 motor starter protectors Solid-state contactors 1-phase, 3RF23 3-phase, 3RF24 5/26, 5/27 4/5, 4/13 ... 4/20, 4/31 ... 4/33 4/14 ... 4/19 4/20 5/38 ... 5/51 5/50, 5/51 5/46 ... 5/49 5/38 ... 5/45 Solid-state overload relays Accessories for high-feature applications for standard applications Solid-state relays 1-phase, 3RF20 1-phase, 3RF21 3-phase, 3RF22 4/5, 4/7 ... 4/12 4/8 ... 4/10 4/11 4/12 4/2 ... 4/6 4/5 ... 4/30 4/31 ... 4/33 Solid-state switching devices for resistive loads for switching motors 19/26 Spacers for miniature circuit breakers Speed monitoring 7/61, 7/62 19/124 SR60 busbar systems Auxiliary switches DIAZED bus-mounting bases DIAZED covers DIAZED gauge rings LV HRC bus-mounting fuse bases LV HRC fuse switch disconnectors NEOZED bus-mounting bases NEOZED bus-mounting switch disconnectors NEOZED covers ... 19/134 Stabilized power supplies LOGO!Power SITOP 19/131 19/130 19/130 19/130 19/131 19/131 19/129 19/131 19/130 11/2, 11/11 11/11 ... 11/16 6/10, 6/52 Standard mounting rail adapters ... 20/28 Standards 20/11 Starter combinations Circuit breakers 5/2, 5/11 16/12 ... 16/13 Starters, encapsulated Direct-on-line starters Reversing starters 6/130 Siemens LV 1 · 2008 ... 6/133 6/131 6/132 20/39 20 Page LV1_20.book Seite 40 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Subject index Page Summation current transformers Surge suppressors 7/55 3/107, 3/108, 3/119, 3/122, 3/124, 3/126, 6/10 17/4 ... 17/31 Switch disconnectors 17/11 ... 17/13 Accessories Floor mounting 17/5 ... 17/9 17/47 ... 17/69 Fuses - Assembly kits for distribution systems 17/57 ... 17/59 - for extended technical requirements 17/60, 17/61 - for extended technical requirements with fuse monitoring 17/62 ... 17/69 - for power distribution 17/48 ... 17/50 - for power distribution with fuse monitoring 17/51 ... 17/53 17/10 Molded-plastic enclosures with fuses 17/33 ... 17/46 - Accessories 17/37 ... 17/40 - Double-breaks 17/46 - Double-breaks with fuse monitoring 17/46 - Front mounting 17/36 - In-line 17/45, 17/46 - Single-breaks 17/45 - Single-breaks with fuse monitoring 17/45 - Surface mounting and installation 17/34, 17/35 - with isolating plug connector 17/41 ... 17/44 15/40, 18/7 Switch ES Power Switchgear 14/7 Switching magnets 8/86 System components and accessories Accessories 2/65, Addressing units 2/62 ... Analyzers Extension plugs 2/66 2/61 2/64 2/60 5/2, 5/3, 5/14, 16/8 ... 16/11,16/14 ... 16/17, 16/21 ... 16/34, 16/36 ... 16/37, 16/75 System protection Page Page Variable-ratio 10/2, 10/3 Voltage regulators 10/2, 10/56 - Magnetic type - Transformer-type 10/2, 10/3, 10/55, 10/88 10/2, 10/3, 10/5, with selectable voltages 10/47 ... 10/50, 10/56, 10/57, 10/61 ... 10/63, 10/84, 10/85 Thermal overload relays Accessories for standard applications 5/52 ... 5/56 5/52 5/56 5/55 Thermistor transformer protection 10/50, 10/54, 10/85 Three-phase busbar systems for 3RV1 motor starter protectors 5/21 Three-phase power supplies Filtered Non-stabilized Unfiltered ... 5/2, ... 5/23 11/2, 11/7, 11/8 11/2 11/2, 11/10 Three-phase transformers 10/3, 10/57 ... 10/88 Auto- 10/3, 10/57, 10/61 ... 10/63,10/84, 10/85 - for matching purposes 10/3, 10/86, 10/87 10/3, 10/57 ... 10/59,10/61, 10/62 Control 10/63, 10/84, 10/85 Converter Enclosures 10/62, 10/84, 10/85 10/3, 10/57 ... 10/62 Isolating 10/3, 10/57 ... 10/62 Mains Matching 10/3, 10/63 ... 10/73, 10/86, 10/87 - with cURus approval 10/3, 10/74 ... 10/83 - with selectable voltages 10/3, 10/84, 10/85 Pillar-type 10/3 10/3, 10/63 ... 10/85 Power 10/3, 10/57, 10/61, 10/62 Safety Toroidal-core 10/3 10/3 Variable-ratio Voltage regulators 10/3, 10/88 - Transformer-type with selectable voltages 10/3, 10/57, 10/61, 10/61 ... 10/63, 10/84, 10/85 19/160 Time counters Time-delay blocks for contactors and contactor relays, solid-state Tools for Cage Clamp 3/106 5/29, 5/51, 5/57 Transmission media Shaped cables 2/59 Trip units for 3RV1 motor starter protectors 5/20 9/3, 9/97 Two-hand operation consoles U Undervoltage releases for 3RV1 motor starter protectors Undervoltage trip units for circuit breakers 5/2, 5/17, 5/20 15/22, 15/37, 16/38, 16/40 ... 16/41, 16/76 4/4 Unit labeling plates 2/44 User modules V Vacuum contactors 3/26 ... 3/28 Variable-ratio transformers Pillar-type Toroidal-core 10/2, 10/3 10/2, 10/3 Voltage monitoring 7/47, 7/48 Voltage regulators Magnetic type Transformer-type 10/2, 10/56 10/2, 10/3, 10/55, 10/88 Voltage transformer circuit breakers 5/2, 5/16 19/156 Voltmeter selector switches Toroidal-core variable-ratio transformers 10/2, 10/3 T Transformer protection Temperature monitoring relays, 3RS10, 3RS11 7/63 ... 7/70 Transformers Auto- Terminal blocks Accessories 14/28 ... 14/23, Combination plug-in terminals for 3RV1 motor starter protectors for overload relays Insulation displacement connection 14/25, Plug-in connection Screw connection 14/14 ... 14/18 ... Spring-type connections 14/31 14/24 5/27 5/51 14/27 14/26 14/17 14/22 Terminal brackets 5/50, 5/56 Terminal covers for 3RV1 motor starter protectors for overload relays 5/26 5/51, 5/56 Terminal covers for 19/26 Miniature circuit breakers Residual current protective devices 19/27, 19/57 19/160 Time counters 20 Terminal modules for ET 200S motor starters 6/83 ... 6/86 Terminals for "Self-Protected Combination Motor Controller" according to UL 508 20/40 5/26, 5/27 Siemens LV 1 · 2008 5/2, 5/12, 5/15 10/1 ... 10/88 10/2, 10/3, 10/5, 10/47 ... 10/50, 10/57,10/61 ... 10/63, 10/84, 10/85 - for matching purposes 10/3, 10/86, 10/87 10/2, 10/3, 10/5 ... 10/19, Control 10/24 ... 10/41, 10/47,10/48, 10/57 ... 10/59, 10/61, 10/62 10/49, 10/63, 10/84, 10/85 Converter 10/50 Converters Enclosed 10/2, 10/51 ... 10/53 10/48, 10/62, 10/84, 10/85 Enclosures 10/2, 10/3, 10/5, Isolating 10/24 ... 10/48,10/57 ... 10/62 - for supply of medical premises 10/2, 10/54 - Resin-enclosed 10/2, 10/53 Mains 10/2, 10/3, 10/5 ... 10/48, 10/57 ... 10/62 10/3, 10/49, 10/50, Matching 10/63 ... 10/73, 10/86, 10/87 - with cURus approval 10/3, 10/74 ... 10/83 - with selectable voltages 10/3, 10/84, 10/85 Pillar-type 10/2, 10/3 Power 10/2, 10/3, 10/49, 10/50, 10/63 ... 10/85 10/2, 10/3, 10/5 ... 10/23, 10/47, Safety 10/48, 10/57, 10/61, 10/62 - Resin-enclosed 10/2, 10/51, 10/52 10/2, 10/5 ... 10/56 Single-phase Three-phase 10/3, 10/57 ... 10/88 10/2, 10/3 Toroidal-core W Wall enclosures for residual current protective devices 19/27, 19/57 Wiring modules for contactor assemblies Withdrawable bridging units Withdrawable coils 3/39 15/45 3/116, 3/117 Withdrawable grounding units 15/45 Withdrawable short-circuits 15/45 Withdrawable versions 15/10 ... 15/13, Circuit breakers 15/18 ... 15/21, 15/48, 16/49 ... 16/54 Wye-delta starting 3/49 LV1_20.book Seite 41 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings ■ Overview Order No. Export markings ECCN Page Order No. AL 3K Export markings Page ECCN AL 3KL53 30-1G N 17/33 N N 17/5 3KL53 40-1A N N 17/33 ... 34 3KA50 30-1G N N 17/5 3KL53 40-1G N N 17/33 3KA50 40-1A N N 17/5 3KL55 30-1A N N 17/33 3KA50 40-1G N N 17/5 3KL55 30-1G N N 17/33 3KA51 30-1A N N 17/5 3KL55 40-1A N N 17/33 ... 34 3KA51 30-1G N N 17/5 3KL55 40-1G N N 17/33 3KA51 40-1A N N 17/5 3KL57 30-1A N N 17/33 3KA51 40-1G N N 17/5 3KL57 30-1G N N 17/33 3KA52 30-1A N N 17/5 3KL57 40-1A N N 17/33 ... 34 3KA52 30-1G N N 17/5 3KL57 40-1G N N 17/33 3KA52 40-1A N N 17/5 3KL61 30-1A N N 17/33 3KA52 40-1G N N 17/5 3KL61 30-1G N N 17/33 3KA53 30-1A N N 17/5 3KL61 40-1A N N 17/33 ... 34 3KA53 30-1G N N 17/5 3KL61 40-1G N N 17/33 3KA53 40-1A N N 17/5 3KL62 30-1A N N 17/33 3KA53 40-1G N N 17/5 3KL62 30-1G N N 17/33 3KA55 30-1A N N 17/5 3KM50 30-1A N N 17/41 3KA55 30-1G N N 17/5 3KM50 30-1G N N 17/41 3KA55 40-1A N N 17/5 3KM52 30-1A N N 17/41 3KA55 40-1G N N 17/5 3KM52 30-1G N N 17/41 3KA57 30-1A N N 17/5 3KM53 30-1A N N 17/41 3KA57 30-1G N N 17/5 3KM53 30-1G N N 17/41 3KA57 40-1A N N 17/5 3KM55 30-1A N N 17/41 3KA57 40-1G N N 17/5 3KM55 30-1G N N 17/41 3KA58 30-1A N N 17/5 3KM57 30-1A N N 17/41 3KA58 30-1G N N 17/5 3KM57 30-1G N N 17/41 3KA58 40-1A N N 17/5 3KX22 1 N N 17/7, 17/12 ... 13 3KA58 40-1G N N 17/5 3KX22 3 N N 17/12 ... 13 3KE42 30-0A N N 17/7 3KX22 50 N N 17/12 ... 13 3KE42 30-0B N N 17/7 3KX22 52-0 N N 17/13 3KE42 30-0C N N 17/8 ... 9 3KX22 52-1 N N 17/12 ... 13 3KE42 30-0G N N 17/7 3KX31 N N 17/11, 17/37, 17/43 3KE43 30-0A N N 17/7 3KX35 0 N N 17/36 ... 37, 17/42 ... 43 3KE43 30-0B N N 17/7 3KX35 1 N N 17/6, 17/11, 17/35 ... 36, 17/42 3KE43 30-0C N N 17/8 ... 9 3KX35 2 N N 17/35 ... 36, 17/42 3KE43 30-0G N N 17/7 3KX35 3 N N 17/6, 17/11, 17/35 ... 36, 17/42 3KE44 30-0A N N 17/7 3KX35 52-3D N N 17/11, 17/36, 17/42 3KE44 30-0B N N 17/7 3KX35 52-3E N N 17/11, 17/37, 17/43 3KE44 30-0C N N 17/8 ... 9 3KX35 53 N N 17/11, 17/36, 17/42 3KE44 30-0G N N 17/7 3KX35 56 N N 17/6, 17/35 3KE45 30-0A N N 17/7 3KX35 57 N N 17/11 ... 12, 17/37, 17/43 3KE45 30-0B N N 17/7 3KX35 6 N N 17/38 3KE45 30-0C N N 17/8 ... 9 3KX36 N N 17/38 3KE45 30-0G N N 17/7 3KY22 0 N N 17/12 3KL50 30-1A N N 17/33 3KY22 32 N N 17/13 3KL50 30-1G N N 17/33 3KY22 34 N N 17/13 3KL50 40-1A N N 17/33 ... 34 3L 3KL50 40-1G N N 17/33 3LD20 0 N N 17/15 ... 16 3KL52 30-1A N N 17/33 3LD20 1 N N 17/20 ... 21, 17/23 3KL52 30-1G N N 17/33 3LD20 2 N N 17/17 3KL52 40-1A N N 17/33 ... 34 3LD20 3 N N 17/24 ... 25 3KL52 40-1G N N 17/33 3LD20 4 N N 17/20, 17/22 3KL53 30-1A N N 17/33 3LD20 5 N N 17/15 ... 16, 17/18 Siemens LV 1 · 2008 20 N 3KA50 30-1A 20/41 LV1_20.book Seite 42 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Order No. Export markings Page Order No. ECCN AL N N 17/26 3NC24 31-3 on req. 3LD21 0 N N 17/15 ... 16, 17/19 3NC24 31-3C N N 17/55, 17/67, 19/114 3LD21 1 N N 17/20 ... 21, 17/23 3NC24 32-0 N N 19/114 3LD21 2 N N 17/17, 17/19 3NC24 32-3 on req. 3LD21 3 N N 17/24 ... 25 3NC24 32-3C N N 17/39, 17/67, 19/114 3LD21 4 N N 17/20, 17/22 3NC3 N N 19/116 ... 118 3LD21 5 N N 17/15 ... 16, 17/18 3NC5 N N 19/119 3LD21 6 N N 17/26 ... 27 3NC73 2 N N 19/119 3LD22 0 N N 17/15 ... 16, 17/19 3NC73 3 N N 19/119 3LD22 1 N N 17/20 ... 21, 17/23 3NC8 N N 17/39, 17/55, 17/67, 19/114 3LD22 2 N N 17/17, 17/19 3ND N N 19/88 3LD22 3 N N 17/24 ... 25 3NE1 N N 3LD22 4 N N 17/20, 17/22 17/38 ... 39, 17/54, 17/66, 19/114 ... 116 3LD22 5 N N 17/15 ... 16, 17/18 3NE32 N N 17/39, 17/55, 17/66, 19/117 3NE33 N N 17/39, 17/55, 17/67, 19/117 3NE34 N N 19/117 3NE35 N N 19/119 3NE36 2 N N 19/117 3NE36 35-0 N N 19/117 3NE36 35-6 N N 19/117 3NE36 36 N N 19/117 3NE36 37 N N 19/117 ... 118 3NE4 N N 17/39, 17/55, 17/66 ... 67, 19/117, 19/119 3LD25 0 3LD25 1 3LD25 2 3LD25 3 3LD25 4 3LD25 5 3LD25 6 N N N N N N N N N N N N N N N N ECCN Page 3LD20 6 3LD22 6 17/26 ... 27 17/15 ... 16, 17/19 17/20 ... 21, 17/23 17/19 17/24 ... 25 17/20, 17/22 17/15 ... 16 17/26 ... 27 AL 17/39 17/55 3LD27 N N 17/15 ... 16, 17/19 ... 21, 17/24 ... 27 3LD28 N N 17/15 ... 16, 17/20 ... 21, 17/24 ... 26 3NE5 N N 19/118 3LD92 00 N N 17/16 ... 18, 17/21 ... 22, 17/24 ... 26, 17/28 ... 31 3NE6 N N 19/119 3NE7 N N 19/118 3NE8 N N 17/39, 17/55, 17/66, 19/115 ... 116 3NE9 N N 19/119 3NG N N 19/96 3NH N N 19/93 ... 95, 19/131 3NJ41 N N 17/70 ... 71 3LD92 01 3LD92 20 3LD92 21 N N N N N N 17/28 17/17 ... 18, 17/24 ... 25, 17/29 17/29 3LD92 24 N N 17/28 ... 29 3LD92 50 N N 17/15 ... 16, 17/20, 17/22, 17/24 ... 25, 17/30 3LD92 51 N N 17/30 3NJ49 11-1 N N 17/73 3LD92 80 N N 17/15 ... 16, 17/20 ... 21, 17/24 ... 26, 17/31 3NJ49 11-2 N N 17/73 3NJ49 11-3 N N 17/73 3NJ49 11-4 N N 17/73 3NJ49 11-5A N N 17/73 3NJ49 11-5B on req. 17/73 3NJ49 11-5C on req. 17/73 3NJ49 11-6 on req. 3NJ49 12-1A N N 3NJ49 12-1D N N 17/72 3NJ49 12-2 N N 17/72 3NJ49 12-3 N N 17/72 3NJ49 13 N N 17/73 3NJ49 14 N N 17/73 3NJ49 15-1B N N 17/73 3NJ49 15-1C N N 17/73 3NJ49 15-1E N N 17/74 3NJ49 15-1F N N 17/74 3NJ49 15-2B N N 17/73 3NJ49 15-2C N N 17/73 3NJ49 15-2D N N 17/74 3NJ49 15-2E N N 17/74 3NJ49 15-2F N N 17/74 3LD92 81 N N 17/31 3LD92 84 N N 17/30 ... 31 3LD92 86 N N 17/28 ... 31 3N 20 Export markings 3NA N N 19/82 ... 87 3NC10 00 EAR99H N 19/122 3NC10 03 N N 19/121 3NC10 06 N N 19/121 3NC10 08 N N 19/121 3NC10 1 N N 19/121 3NC10 2 N N 19/121 3NC10 32 N N 19/121 3NC10 38 EAR99H N 19/122 3NC10 38-1 N N 19/122 3NC10 38-2 N N 19/122 3NC10 38-3 N N 19/122 3NC10 9 N N 19/122 3NC14 N N 19/121 ... 122 3NC22 N N 19/121 ... 122 3NC24 2 N N 17/39, 17/55, 17/67, 19/113 3NC24 31-0 N N 19/114 20/42 Siemens LV 1 · 2008 17/73 3NJ49 12-1B 17/72 17/72 LV1_20.book Seite 43 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Order No. Export markings Page Order No. Export markings Page ECCN AL ECCN AL 3NJ49 15-2G N N 17/74 3NW73 23 N N 19/73 3NJ49 15-2H N N 17/74 3NW73 24 N N 19/72 3NJ49 15-2J N N 17/74 3NW73 33 N N 19/73 3NJ49 15-2K N N 17/74 3NW73 34 N N 19/72 3NJ49 18-0A N N 17/72 3NW73 53 N N 19/73 3NJ49 18-0D N N 17/72 3NW73 54 N N 19/72 3NJ49 18-0E N N 17/72 3NW73 63 N N 19/73 3NJ49 18-1 N N 17/73 3NW73 64 N N 19/72 3NJ50 N N 17/70 3NW74 N N 19/131 3NJ56 N N 17/70 3NW75 N N 19/74 3NJ59 N N 17/72 ... 73 3NW79 N N 19/73 3NJ6 N N 17/44 ... 45 3NW8 N N 19/72 3NP40 1 N N 14/40, 14/53, 17/47 ... 49, 19/98 ... 100, 19/131 3NX N N 19/89, 19/95 ... 96 3NY10 N N 17/65, 19/109 3NY11 N N 17/65, 17/68, 19/110 3NY12 N N 17/53, 17/56 ... 58, 17/68, 19/106 ... 108, 19/110 ... 111 3NP40 70 N N 17/47, 17/50, 19/98, 19/101 3NP40 75-0CE N N 14/40, 17/48, 19/98 3NP40 75-0CF EAR99 N 14/40, 17/48, 19/98 3NP40 75-0CJ N N 14/40, 17/48, 19/98 3NY13 N N 17/65, 19/109 3NP40 75-0CK N N 14/40, 17/48, 19/98 3NY14 2 N N 17/65, 19/109 3NP40 75-0F N N 14/41, 17/51 3NY14 3 N N 17/53, 19/106 3NP40 75-1 N N 14/40 ... 41, 17/48, 17/51, 19/99 3NY15 N N 17/65, 19/109 3NP40 76 N N 14/53 ... 54, 17/49, 17/52, 19/100, 19/131 3NY18 N N 17/54, 19/85, 19/106 3NY19 03 N N 17/68, 19/111 3NY19 07 N N 17/68, 19/111 3NY19 10 N N 17/54, 17/65, 19/106, 19/109 3NP42 70 N N 17/47, 17/50, 19/98, 19/101 3NP42 75 N N 14/40 ... 41, 17/48, 17/51, 19/99 3NP42 76 N N 14/53 ... 54, 17/49, 17/52, 19/100, 19/131 3NY19 11 N N 17/54, 17/65, 19/106, 19/109 17/47, 17/50, 19/98, 19/101 3NY19 15 N N 17/65, 19/109 14/53 ... 54, 17/49, 17/52, 19/100, 19/131 3NY19 4 N N 17/68, 19/111 3NY19 9 N N 17/53, 19/105 3NP43 70 3NP43 76 N N N N 3NP44 70 N N 17/47, 17/50, 19/98, 19/101 3NY30 30 N N 17/54, 19/106 3NP44 76 N N 14/53 ... 54, 17/49, 17/52, 19/100, 19/131 3NY30 33 N N 17/65, 19/109 3NY30 34 N N 17/65, 19/109 3NY30 35 N N 17/54, 19/106 3NP50 60 N N 17/59, 17/61, 17/63, 19/102 ... 104 3NP50 65 N N 17/60, 17/62, 17/64, 19/102 ... 103, 19/105 3NY4 N N 17/65, 19/110 3NY7 N N 17/53 ... 54, 17/56, 17/58, 19/105 ... 107, 19/109, 19/131 3NP52 N N 17/59, 17/61, 17/63, 19/102 ... 104 3NP53 N N 17/59, 17/61, 17/63, 19/102 ... 104 3NP54 N N 17/59, 17/61, 17/63, 19/102 ... 104 3RA11 N N 6/32 ... 39 3NW1 N N 19/75 3RA12 N N 6/40 ... 47 3NW2 N N 19/75 3RA13 N N 3/33 ... 36 3NW3 N N 19/75 3RA14 1 N N 3/42 3NW6 N N 19/71 3RA14 23-8XC21-1AC EAR99 N 3/43 3NW70 13 N N 19/73 3RA14 23-8XC21-1AG N N 3/43 3NW70 14 N N 19/72 3RA14 23-8XC21-1AL EAR99 N 3/43 3NW70 23 N N 19/73 3RA14 23-8XC21-1B EAR99 N 3/43 3NW70 24 N N 19/72 3RA14 25-8XC21-1AC EAR99 N 3/43 3NW70 33 N N 19/73 3RA14 25-8XC21-1AG N N 3/43 3NW70 34 N N 19/72 3RA14 25-8XC21-1AL EAR99 N 3/43 3NW70 53 N N 19/73 3RA14 25-8XC21-1B N N 3/43 3NW70 54 N N 19/72 3RA14 3 N N 3/44 ... 45 3NW70 63 N N 19/73 3RA14 4 N N 3/46 3NW70 64 N N 19/72 3RA19 0 N N 6/51 3NW71 N N 19/72 ... 73 3RA19 11 N N 5/28 ... 29, 6/9, 6/50, 6/52 3NW72 N N 19/72 ... 73 3RA19 12 N N 3/39 3NW73 13 N N 19/73 3RA19 13-1 N N 6/53 3NW73 14 N N 19/72 3RA19 13-2 EAR99 N 3/38, 3/47, 6/50 Siemens LV 1 · 2008 20 3R 20/43 LV1_20.book Seite 44 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings 20 Order No. Export markings Page Order No. Export markings Page ECCN AL ECCN AL 3RA19 13-3 N N 3/39, 3/47 3RB23 N N 5/48 3RA19 21 N N 5/28, 6/9, 6/17, 6/50 3RB29 0 N N 5/49 3RA19 22 N N 3/39, 5/29, 6/10, 6/51 ... 52 3RB29 1 N N 5/50 3RA19 23 N N 3/37 ... 39, 3/47, 6/50 ... 51, 6/53 3RB29 2 N N 5/50 3RA19 24 N N 3/37, 6/51 3RB29 5 N N 5/49 3RA19 31 N N 5/28, 6/9, 6/17, 6/50 3RB29 6 N N 5/49 3RA19 32 N N 3/39, 3/47, 6/51 3RB29 8 N N 5/48 ... 49, 5/51 3RA19 33 N N 3/38 ... 39, 3/47, 6/50 ... 51, 6/53 3RE10 N N 6/131 3RA19 41 N N 5/28, 6/9, 6/17, 6/50 3RE13 N N 6/132 3RA19 42 N N 3/39, 3/47, 6/51 3RE19 13-1 EAR99 N 6/133 3RA19 43 N N 3/38 ... 39, 3/47, 6/50 ... 51 3RE19 13-2 N N 6/133 3RA19 52 N N 3/37, 3/47 3RE19 2 N N 6/133 3RA19 53 N N 3/38 ... 39, 3/47 3RE19 3 N N 6/133 3RA19 54 N N 3/37 3RF20 20-1AA02 N N 4/11 3RA19 62 N N 3/37, 3/47 3RF20 20-1AA04 EAR99 N 4/11 3RA19 63 N N 3/38, 3/47 3RF20 20-1AA2 EAR99 N 4/11 3RA19 72 N N 3/37, 3/47 3RF20 20-1AA4 N N 4/11 3RA19 73 N N 3/38, 3/47 3RF20 30-1AA02 N N 4/11 3RA51 EAR99 N 6/71 3RF20 30-1AA04 EAR99 N 4/11 3RA52 N N 6/73 3RF20 30-1AA06 EAR99 N 4/11 3RA71 00 N N 6/62 3RF20 30-1AA2 EAR99 N 4/11 3RA71 01-0A N N 6/58 ... 59 3RF20 30-1AA4 N N 4/11 3RA71 01-0B N N 6/58 ... 59 3RF20 30-1B EAR99 N 4/11 3RA71 01-0C N N 6/58 ... 59 3RF20 50-1AA02 N N 4/11 3RA71 01-0DA17-0AB EAR99 N 6/59 3RF20 50-1AA04 EAR99 N 4/11 3RA71 01-0DA17-0AL N N 6/58 3RF20 50-1AA06 EAR99 N 4/11 3RA71 01-0EA17-0AB EAR99 N 6/59 3RF20 50-1AA2 EAR99 N 4/11 3RA71 01-0EA17-0AL N N 6/58 3RF20 50-1AA44 EAR99 N 4/11 3RA71 01-0FA17-0AB EAR99 N 6/59 3RF20 50-1AA45 N N 4/11 3RA71 01-0FA17-0AL N N 6/58 3RF20 50-4 N N 4/11 3RA71 01-0G N N 6/58 ... 59 3RF20 70-1AA02 N N 4/11 3RA71 01-0H N N 6/58 ... 59 3RF20 70-1AA04 EAR99 N 4/11 3RA71 01-0J N N 6/58 ... 59 3RF20 70-1AA06 EAR99 N 4/11 3RA71 01-0K N N 6/58 ... 59 3RF20 70-1AA2 EAR99 N 4/11 3RA71 01-1 N N 6/58 ... 59 3RF20 70-1AA4 N N 4/11 3RA71 02-1C N N 6/58 ... 59 3RF20 90-1AA02 N N 4/11 3RA71 02-1D N N 6/58 ... 59 3RF20 90-1AA04 EAR99 N 4/11 3RA71 02-1E N N 6/58 ... 59 3RF20 90-1AA06 EAR99 N 4/11 3RA71 02-1FA26-0AB EAR99 N 6/59 3RF20 90-1AA2 EAR99 N 4/11 3RA71 02-1FA26-0AL N N 6/58 3RF20 90-1AA4 N N 4/11 3RA71 02-1G N N 6/58 ... 59 3RF21 20-1AA02 N N 4/8 3RA71 02-1HA26-0AB EAR99 N 6/59 3RF21 20-1AA04 EAR99 N 4/8 3RA71 02-1HA26-0AL N N 6/58 3RF21 20-1AA2 EAR99 N 4/8 3RA71 02-1J N 6/58 ... 59 3RF21 20-1AA4 N N 4/8 3RA71 02-1KA26-0AB EAR99 N 6/59 3RF21 20-1B N N 4/8 3RA71 02-1KA26-0AL N N 6/58 3RF21 20-2AA02 N N 4/9 3RA71 02-4 N N 6/58 ... 59 3RF21 20-2AA04 EAR99 N 4/9 3RA71 1 N N 6/60, 6/62 3RF21 20-2AA2 EAR99 N 4/9 3RA71 2 N N 6/60, 6/62 3RF21 20-2AA4 N N 4/9 3RA71 3 N N 6/61 ... 62 3RF21 20-3AA02 N N 4/10 3RA71 4 N N 6/61 ... 62 3RF21 20-3AA04 EAR99 N 4/10 3RB1 N N 5/27, 5/51, 6/52, 7/12, 7/18 3RF21 20-3AA2 EAR99 N 4/10 3RB20 N N 5/40 ... 43 3RF21 30-1AA02 N N 4/8 3RB21 N N 5/44 ... 45 3RF21 30-1AA04 EAR99 N 4/8 3RB22 N N 5/48 3RF21 30-1AA06 EAR99 N 4/8 20/44 N Siemens LV 1 · 2008 LV1_20.book Seite 45 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Export markings Page Order No. Export markings Page ECCN AL ECCN AL 3RF21 30-1AA2 EAR99 N 4/8 3RF23 10-2AA06 EAR99 N 4/17 3RF21 30-1AA4 N N 4/8 3RF23 10-2AA2 EAR99 N 4/17 3RF21 30-1B N N 4/8 3RF23 10-3AA02 N N 4/18 3RF21 50-1AA02 N N 4/8 3RF23 10-3AA04 EAR99 N 4/18 3RF21 50-1AA04 EAR99 N 4/8 3RF23 10-3AA06 EAR99 N 4/18 3RF21 50-1AA06 EAR99 N 4/8 3RF23 10-3AA2 EAR99 N 4/18 3RF21 50-1AA2 EAR99 N 4/8 3RF23 20-1AA02 N N 4/14 3RF21 50-1AA4 N N 4/8 3RF23 20-1AA04 EAR99 N 4/14 3RF21 50-1BA04 N N 4/8 3RF23 20-1AA06 EAR99 N 4/14 3RF21 50-1BA06 EAR99 N 4/8 3RF23 20-1AA1 N N 4/14 3RF21 50-1BA2 EAR99 N 4/8 3RF23 20-1AA2 EAR99 N 4/14 3RF21 50-2AA02 N N 4/9 3RF23 20-1AA4 N N 4/14 3RF21 50-2AA04 EAR99 N 4/9 3RF23 20-1BA02 EAR99 N 4/15 3RF21 50-2AA06 EAR99 N 4/9 3RF23 20-1BA04 N N 4/15 3RF21 50-2AA2 EAR99 N 4/9 3RF23 20-1BA06 EAR99 N 4/15 3RF21 50-3AA02 N N 4/10 3RF23 20-1BA2 EAR99 N 4/15 3RF21 50-3AA04 EAR99 N 4/10 3RF23 20-1BA4 N N 4/15 3RF21 50-3AA06 EAR99 N 4/10 3RF23 20-1CA0 EAR99 N 4/16 3RF21 50-3AA2 EAR99 N 4/10 3RF23 20-1CA22 EAR99 N 4/16 3RF21 70-1AA02 N N 4/8 3RF23 20-1CA24 N N 4/16 3RF21 70-1AA04 EAR99 N 4/8 3RF23 20-1CA4 EAR99 N 4/16 3RF21 70-1AA05 N N 4/8 3RF23 20-1DA02 N N 4/16 3RF21 70-1AA06 EAR99 N 4/8 3RF23 20-1DA04 EAR99 N 4/16 3RF21 70-1AA2 EAR99 N 4/8 3RF23 20-1DA2 EAR99 N 4/16 3RF21 70-1AA4 N N 4/8 3RF23 20-1DA4 N N 4/16 3RF21 70-1B N N 4/8 3RF23 20-2AA02 N N 4/17 3RF21 90-1AA02 N N 4/8 3RF23 20-2AA04 EAR99 N 4/17 3RF21 90-1AA04 EAR99 N 4/8 3RF23 20-2AA06 EAR99 N 4/17 3RF21 90-1AA06 EAR99 N 4/8 3RF23 20-2AA2 EAR99 N 4/17 3RF21 90-1AA2 EAR99 N 4/8 3RF23 20-2CA0 EAR99 N 4/17 3RF21 90-1AA4 N N 4/8 3RF23 20-2CA22 EAR99 N 4/17 3RF21 90-1B N N 4/8 3RF23 20-2CA24 N N 4/17 3RF21 90-2AA02 N N 4/9 3RF23 20-2D EAR99 N 4/17 3RF21 90-2AA04 EAR99 N 4/9 3RF23 20-3AA02 N N 4/18 3RF21 90-2AA06 EAR99 N 4/9 3RF23 20-3AA04 EAR99 N 4/18 3RF21 90-2AA2 EAR99 N 4/9 3RF23 20-3AA06 EAR99 N 4/18 3RF21 90-3AA02 N N 4/10 3RF23 20-3AA2 EAR99 N 4/18 3RF21 90-3AA04 EAR99 N 4/10 3RF23 20-3AA4 N N 4/18 3RF21 90-3AA06 EAR99 N 4/10 3RF23 20-3DA02 N N 4/19 3RF21 90-3AA2 EAR99 N 4/10 3RF23 20-3DA04 EAR99 N 4/19 3RF21 90-3AA4 N N 4/10 3RF23 20-3DA2 EAR99 N 4/19 3RF22 N N 4/12 3RF23 30-1AA02 N N 4/14 3RF23 10-1AA02 N N 4/14 3RF23 30-1AA04 EAR99 N 4/14 3RF23 10-1AA04 EAR99 N 4/14 3RF23 30-1AA06 EAR99 N 4/14 3RF23 10-1AA06 EAR99 N 4/14 3RF23 30-1AA1 N N 4/14 3RF23 10-1AA12 EAR99 N 4/14 3RF23 30-1AA2 EAR99 N 4/14 3RF23 10-1AA14 N N 4/14 3RF23 30-1AA4 N N 4/14 3RF23 10-1AA2 EAR99 N 4/14 3RF23 30-1BA02 EAR99 N 4/15 3RF23 10-1AA4 N N 4/14 3RF23 30-1BA04 N N 4/15 3RF23 10-1BA02 EAR99 N 4/15 3RF23 30-1BA06 EAR99 N 4/15 3RF23 10-1BA04 N N 4/15 3RF23 30-1BA2 EAR99 N 4/15 3RF23 10-1BA06 EAR99 N 4/15 3RF23 30-1BA4 N N 4/15 3RF23 10-1BA2 EAR99 N 4/15 3RF23 30-1C EAR99 N 4/16 3RF23 10-2AA02 N N 4/17 3RF23 30-1D N N 4/16 3RF23 10-2AA04 EAR99 N 4/17 3RF23 30-3AA02 N N 4/18 Siemens LV 1 · 2008 20 Order No. 20/45 LV1_20.book Seite 46 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings 20 Order No. Export markings Page Order No. Export markings Page ECCN AL ECCN AL 3RF23 30-3AA04 EAR99 N 4/18 3RF23 90-3AA26 EAR99 N 4/18 3RF23 30-3AA06 EAR99 N 4/18 3RF23 90-3AA4 N N 4/18 3RF23 30-3AA2 EAR99 N 4/18 3RF23 90-3BA02 N N 4/19 3RF23 30-3AA4 N N 4/18 3RF23 90-3BA04 N N 4/19 3RF23 40-1AA02 N N 4/14 3RF23 90-3BA06 EAR99 N 4/19 3RF23 40-1AA04 EAR99 N 4/14 3RF23 90-3BA2 EAR99 N 4/19 3RF23 40-1AA06 EAR99 N 4/14 3RF24 N N 4/20, 4/32 ... 33 3RF23 40-1AA1 N N 4/14 3RF29 N N 4/10, 4/19, 4/26 ... 30 3RF23 40-1AA2 EAR99 N 4/14 3RG7 EAR99H N 2/17 3RF23 40-1AA4 N N 4/14 3RG90 02-0DA EAR99 N 2/51 3RF23 40-1BA02 EAR99 N 4/15 3RG90 02-0DB EAR99 N 2/51 3RF23 40-1BA04 N N 4/15 3RG90 02-0DC EAR99 N 2/51 3RF23 40-1BA06 EAR99 N 4/15 3RG90 02-0DE N N 2/51 3RF23 40-1BA2 EAR99 N 4/15 3RG90 04-0DA EAR99 N 2/51 3RF23 40-3AA02 N N 4/18 3RG90 04-0DB EAR99 N 2/51 3RF23 40-3AA04 EAR99 N 4/18 3RG90 04-0DC EAR99 N 2/51 3RF23 40-3AA06 EAR99 N 4/18 3RG90 04-0DE N N 2/51 3RF23 40-3AA2 EAR99 N 4/18 3RG90 05 EAR99 N 2/53 3RF23 40-3AA4 N N 4/18 3RH11 22-1A N N 3/70 3RF23 50-1AA02 N N 4/14 3RH11 22-1B N N 3/70 3RF23 50-1AA04 EAR99 N 4/14 3RH11 22-1H N N 3/78 3RF23 50-1AA06 EAR99 N 4/14 3RH11 22-1J N N 3/78 3RF23 50-1AA1 N N 4/14 3RH11 22-1K N N 3/78 3RF23 50-1AA2 EAR99 N 4/14 3RH11 22-1M N N 3/78 3RF23 50-1AA4 N N 4/14 3RH11 22-1V N N 3/78 3RF23 50-1BA02 EAR99 N 4/15 3RH11 22-1W N N 3/78 3RF23 50-1BA04 N N 4/15 3RH11 22-2A N N 3/70 3RF23 50-1BA06 EAR99 N 4/15 3RH11 22-2B N N 3/70 3RF23 50-1BA2 EAR99 N 4/15 3RH11 22-2H N N 3/78 3RF23 50-1BA4 N N 4/15 3RH11 22-2J N N 3/78 3RF23 50-3AA02 N N 4/18 3RH11 22-2K N N 3/59, 3/78 3RF23 50-3AA04 EAR99 N 4/18 3RH11 22-2M N N 3/78 3RF23 50-3AA06 EAR99 N 4/18 3RH11 22-2V N N 3/78 3RF23 50-3AA2 EAR99 N 4/18 3RH11 22-2W N N 3/78 3RF23 50-3AA4 N N 4/18 3RH11 31-1A N N 3/70 3RF23 70-1BA02 EAR99 N 4/15 3RH11 31-1B N N 3/70 3RF23 70-1BA04 N N 4/15 3RH11 31-1H N N 3/78 3RF23 70-1BA06 EAR99 N 4/15 3RH11 31-1J N N 3/78 3RF23 70-1BA2 EAR99 N 4/15 3RH11 31-1K N N 3/78 3RF23 70-3AA02 N N 4/18 3RH11 31-1M N N 3/78 3RF23 70-3AA04 N N 4/18 3RH11 31-1V N N 3/78 3RF23 70-3AA06 EAR99 N 4/18 3RH11 31-1W N N 3/78 3RF23 70-3AA2 EAR99 N 4/18 3RH11 31-2A N N 3/70 3RF23 70-3AA4 N N 4/18 3RH11 31-2B N N 3/70 3RF23 70-3BA02 EAR99 N 4/19 3RH11 31-2H N N 3/78 3RF23 70-3BA04 N N 4/19 3RH11 31-2J N N 3/78 3RF23 70-3BA06 EAR99 N 4/19 3RH11 31-2K N N 3/78 3RF23 70-3BA2 EAR99 N 4/19 3RH11 31-2M N N 3/78 3RF23 90-1BA02 N N 4/15 3RH11 31-2V N N 3/78 3RF23 90-1BA04 N N 4/15 3RH11 31-2W N N 3/78 3RF23 90-1BA06 EAR99 N 4/15 3RH11 40-1A N N 3/70 3RF23 90-1BA2 EAR99 N 4/15 3RH11 40-1B N N 3/70 3RF23 90-3AA0 N N 4/18 3RH11 40-1H N N 3/78 3RF23 90-3AA22 N N 4/18 3RH11 40-1J N N 3/78 3RF23 90-3AA24 EAR99 N 4/18 3RH11 40-1K N N 3/78 20/46 Siemens LV 1 · 2008 LV1_20.book Seite 47 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Export markings Page Order No. Export markings Page ECCN AL ECCN AL 3RH11 40-1M N N 3/78 3RK13 01-0A N N 6/79, 6/105 3RH11 40-1V N N 3/78 3RK13 01-0BB0 EAR99 N 6/78 3RH11 40-1W N N 3/78 3RK13 01-0BB1 N N 6/79, 6/105 3RH11 40-2A N N 3/70 3RK13 01-0BB2 N N 6/79 3RH11 40-2B N N 3/70 3RK13 01-0CB0 EAR99 N 6/78 3RH11 40-2H N N 3/78 3RK13 01-0CB1 N N 6/79, 6/105 3RH11 40-2J N N 3/78 3RK13 01-0CB2 N N 6/79 3RH11 40-2K N N 3/78 3RK13 01-0D EAR99 N 6/78 3RH11 40-2M N N 3/78 3RK13 01-0E EAR99 N 6/78 3RH11 40-2V N N 3/78 3RK13 01-0F EAR99 N 6/78 3RH11 40-2W N N 3/78 3RK13 01-0G EAR99 N 6/78 3RH12 44-1A N N 3/70 3RK13 01-0H EAR99 N 6/78 3RH12 44-1B N N 3/70 3RK13 01-0J EAR99 N 6/78 3RH12 44-2A N N 3/70 3RK13 01-0K EAR99 N 6/78 3RH12 44-2B N N 3/70 3RK13 01-1 EAR99 N 6/78 3RH12 62-1A N N 3/70 3RK13 03-2 N N 6/129 3RH12 62-1B N N 3/70 3RK13 03-5 N N 6/129 3RH12 62-2A N N 3/70 3RK13 03-6B N N 6/129 3RH12 62-2B N N 3/70 EAR99 N 6/129 3RH14 22-1A N N 3/72 3RK13 03-6DS743AA0 3RH14 22-1B N N 3/72 3RK13 03-6DS743AA3 N N 6/129 3RH14 31-1A N N 3/72 3RK13 03-6E N N 6/129 3RH14 31-1B N N 3/72 3RK13 04 N N 6/115 ... 116, 6/118 3RH14 40-1A N N 3/72 3RK13 22 -- 3RH14 40-1B N N 3/72 3RK13 23-2 N N 6/129 3RH19 1 N N 3/100, 3/102, 3/104, 6/48 EAR99 N 6/129 3RH19 21 N N 3/100 ... 101, 3/103 ... 104, 6/48 3RK13 23-5BS443AA0 3RH19 24 N N 3/110 N 6/129 EAR99 N 2/50 3RK13 23-5BS443AA3 N 3RK11 00-1CE 3RK11 00-1CG EAR99 N 2/50 3RK13 23-5C N N 6/129 3RK13 23-6 N N 6/129 3RK14 00-0B EAR99 N 2/50 3RK14 00-0CD N N 2/53 3RK14 00-0CE0 EAR99 N 2/51 3RK14 00-0CE1 N N 2/57, 7/28 3RK14 00-0G N N 2/39 3RK14 00-1B N N 2/39 3RK14 00-1CD N N 2/53 3RK14 00-1CE N N 2/50 3RK14 00-1CG N N 2/50 3RK14 00-1CQ N N 2/35 3RK14 00-1CR EAR99 N 2/37 3RK14 00-1CT N N 2/42 3RK14 00-1D N N 2/35 3RK14 00-1K EAR99 N 6/10, 6/69 3RK14 00-1MG EAR99 N 6/10, 6/69 3RK14 00-1MQ00 N N 2/35 3RK14 00-1MQ01 EAR99 N 6/67 3RK14 00-1MQ03 EAR99 N 6/67 3RK14 00-1N EAR99 N 6/67 3RK14 02-0 N N 2/50 3RK14 02-3C N N 2/50 3RK14 02-3K EAR99 N 6/10, 6/69 3RK14 02-3L EAR99 N 6/10, 6/69 3RK14 05 N N 2/17 3RK14 08 N N 2/35, 2/55 3RK11 00-1CQ 3RK11 05-1AE 3RK11 05-1AG 3RK11 05-1BE 3RK11 05-1BG 3RK11 07 3RK12 00-0CD 3RK12 00-0CE00 3RK12 00-0CE02 3RK12 00-0CE03 3RK12 00-0CG00 3RK12 00-0CG02 3RK12 00-0CG03 3RK12 00-0CQ 3RK12 00-0CT 3RK12 00-0CU 3RK12 00-0D 3RK12 05-0BE 3RK12 05-0BG 3RK12 05-0BQ0 3RK12 05-0BQ21 3RK12 05-0BQ24 3RK12 05-0BQ3 3RK12 05-0C 3RK12 07 N N N N on req. N N N N EAR99 N N EAR99 N N N N N N N N N N N 2/15 2/15 N N N N N N N N N N N N N N N N on req. N 2/15 2/15 on req. N 2/35 2/46 2/53 2/50 2/50 2/54 2/50 2/50 2/54 2/35, 2/39 2/39 2/39 2/35 2/17 2/17 2/17 2/17 2/17 N N N 2/17, 2/42 2/17 2/46 6/64 Siemens LV 1 · 2008 20 Order No. 20/47 LV1_20.book Seite 48 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Order No. Export markings Order No. Export markings Page ECCN AL ECCN AL 3RK17 01 EAR99 N 6/10, 6/69, 6/74 3RK19 03-0CC N N 6/80 3RK17 02 N N 6/65 3RK19 03-0CD N N 6/79 3RK18 5D992B1 N 2/15 3RK19 03-0CE EAR99 N 6/80 3RK19 01-0C N N 2/35, 2/37, 2/47, 2/66, 6/67 3RK19 03-0CF EAR99 N 6/80 3RK19 01-0E N N 6/10, 6/69, 6/74 3RK19 03-0CG N N 6/79 3RK19 01-0N N N 6/10, 6/69, 6/74 3RK19 03-0CH EAR99 N 1/3, 6/79 3RK19 01-0P N N 6/10, 6/69, 6/74 3RK19 03-1AA EAR99 N 6/110 3RK19 01-1A N N 2/17, 2/47 3RK19 03-1AB EAR99 N 6/110 3RK19 01-1G N N 2/56 3RK19 03-1AC0 EAR99 N 6/110 3RK19 01-1KA00 EAR99 N 2/17, 2/35, 2/37, 2/40, 2/42, 2/47, 2/66, 6/67 3RK19 03-1AC1 N N 6/110 3RK19 03-1AD N N 6/110 3RK19 03-1B N N 6/109 3RK19 03-1C EAR99 N 6/109 3RK19 03-2 N N 6/85 ... 86, 6/105, 6/113 3RK19 03-3AA EAR99 N 6/113 3RK19 03-3AB N N 6/110, 6/113 3RK19 03-3AC EAR99 N 6/105 3RK19 03-3AD EAR99 N 6/105 3RK19 03-3AE EAR99 N 6/110 3RK19 01-1KA01 N N 2/17, 2/35, 2/66, 6/67 3RK19 01-1M N N 2/40, 2/60 ... 61, 2/66 3RK19 01-1NN N N 2/42, 2/65 3RK19 01-1NP on req. 3RK19 01-1NR N N 2/38, 2/43, 2/65 3RK19 01-1P N N 2/40, 2/42, 2/66 3RK19 01-1T N N 2/38, 2/43, 2/65 3RK19 01-2 N N 2/17, 2/40, 2/66 3RK19 01-3 N N 2/38, 2/43, 2/61, 2/65 ... 66, 6/10, 6/69, 6/74 3RK19 03-3B EAR99 N 6/113 3RK19 01-5 N N 2/15 3RK19 03-3C N N 6/109, 6/113 3RK19 02-0A N N 2/35, 2/47, 2/66, 6/65, 6/67, 6/121 3RK19 03-3D EAR99 N 6/109 6/65 3RK19 03-3E N N 6/86, 6/113 6/65 3RK19 04-2 N N 2/61 6/65, 6/120 3RK19 04-3 EAR99 N 2/64 6/65 3RK19 11-0B N N 1/3 6/65, 6/120 3RK19 11-0D EAR99 N 6/120 6/65 3RK19 11-0E EAR99 N 6/121 N N 6/120 3RK19 02-0CA 3RK19 02-0CB 3RK19 02-0CC 3RK19 02-0CD 3RK19 02-0CE 3RK19 02-0CG EAR99 EAR99 EAR99 EAR99 EAR99 N 2/17 N N N N N N 3RK19 02-0CH N N 6/65 3RK19 11-2BE 3RK19 02-0CJ EAR99 N 6/65, 6/121 3RK19 11-2BF N N 6/120 3RK19 02-0CK EAR99 N 6/65 3RK19 11-2BL EAR99 N 6/120 3RK19 02-0CM N N 6/65 3RK19 11-2BM EAR99 N 6/120 6/65 3RK19 11-2BS N N 6/120 6/65 3RK19 2 N N 1/3, 6/79, 6/120 ... 121 6/65 3RK21 N N 2/39 6/65 3RK22 N N 2/35, 2/39, 2/42, 2/46, 2/50 6/65 3RK24 00-0 N N 2/39 6/65, 6/121 3RK24 00-1B N N 2/39, 2/42 N N 2/42, 2/50 3RK19 02-0CN 3RK19 02-0CP 3RK19 02-0CQ 3RK19 02-0CR 3RK19 02-0CS 3RK19 02-0CT N N N N N EAR99 N N N N N N 3RK19 02-0CW N N 6/121 3RK24 00-1C 3RK19 03-0AA N N 6/85, 6/110 3RK24 00-1D EAR99 N 2/35 3RK19 03-0AB0 EAR99 N 6/84 3RK24 00-1F N N 2/35, 2/50 3RK19 03-0AB1 N N 6/84 3RK24 00-1H EAR99 N 2/35 6/84 3RK3 N N 2/25 6/84 3RN10 0 N N 7/72 ... 73 6/80 3RN10 10 N N 7/72 ... 73 6/80 3RN10 11 N N 7/72 ... 73 6/80 3RN10 12 N N 7/72 ... 73 6/80 3RN10 13-1BB N N 7/72 EAR99 N 7/72 3RK19 03-0AC0 3RK19 03-0AC1 3RK19 03-0AE 3RK19 03-0AF 3RK19 03-0AG00 3RK19 03-0AG01 N EAR99 N N N EAR99 N N N N N N 3RK19 03-0AH N N 6/80 3RN10 13-1BW0 3RK19 03-0AJ N N 6/80 3RN10 13-1BW1 N N 7/72 3RK19 03-0AK EAR99 N 6/85 3RN10 13-1G N N 7/72 3RK19 03-0AL EAR99 N 6/85 3RN10 13-2BB N N 7/73 6/82 3RN10 13-2BW00 N N 7/73 3/109, 6/79 3RN10 13-2BW01 EAR99 N 7/73 6/80 3RN10 13-2G N N 7/73 3RK19 03-0B EAR99 3RK19 03-0CA 20 Page 3RK19 03-0CB 20/48 N EAR99 N N N Siemens LV 1 · 2008 LV1_20.book Seite 49 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Export markings Page Order No. Export markings Page ECCN AL 3RP19 03 N N 2/50, 5/51, 6/8, 7/12, 7/36, 7/46, 7/48, 7/50, 7/52, 7/54, 7/59, 7/62, 7/65, 7/68, 7/70, 7/74, 7/79, 7/84, 7/88 ECCN AL 3RN10 2 EAR99 N 7/72 ... 73 3RN10 6 EAR99 N 7/72 ... 73 3RP15 05-1AA N N 7/32 3RP15 05-1AP EAR99 N 7/32 3RP2 N N 7/38 ... 39 3RP15 05-1AQ N N 7/32 3RS10 N N 7/64 ... 65, 7/67 ... 68, 7/70 3RP15 05-1AW N N 7/32 3RS11 00-1CD N N 7/64 3RP15 05-1BP EAR99 N 7/32 3RS11 00-1CK2 N N 7/64 3RP15 05-1BQ N N 7/32 3RS11 00-1CK3 EAR99 N 7/64 3RP15 05-1BT EAR99 N 7/32 3RS11 00-2 N N 7/65 3RP15 05-1BW N N 7/32 3RS11 01 N N 7/64 N N 7/64 3RP15 05-1R EAR99 N 7/32 3RS11 20-1DD 3RP15 05-2AP EAR99 N 7/33 3RS11 20-1DW2 N N 7/64 3RP15 05-2AQ N N 7/33 3RS11 20-1DW3 EAR99 N 7/64 3RP15 05-2AW N N 7/33 3RS11 20-2 N N 7/65 3RP15 05-2BP EAR99 N 7/33 3RS11 21 N N 7/64 3RP15 05-2BQ N N 7/33 3RS11 4 N N 7/67 ... 68 3RP15 05-2BW N N 7/33 3RS17 N N 7/90 ... 91 3RP15 05-2R EAR99 N 7/33 3RS18 N N 3/88 3RP15 1 N N 7/32 ... 33 3RS19 N N 7/68, 7/70 3RP15 25-1AP EAR99 N 7/32 3RS2 N N 7/67 ... 68 N N 3/15 3RP15 25-1AQ N N 7/32 3RT10 15-1A 3RP15 25-1B N N 7/32 3RT10 15-1B N N 3/19 3RP15 25-2AP EAR99 N 7/33 3RT10 15-1H N N 3/79 3RP15 25-2AQ N N 7/33 3RT10 15-1J N N 3/79 3RP15 25-2B N N 7/33 3RT10 15-1K N N 3/79 3RP15 27 N N 7/32 ... 33 3RT10 15-1M N N 3/80 3RP15 3 N N 7/34 ... 35 3RT10 15-1V N N 3/80 3RP15 40-1A N N 7/34 3RT10 15-1W N N 3/80 3RP15 40-1BB N N 7/34 3RT10 15-2A N N 3/15 3RP15 40-1BJ N N 7/34 3RT10 15-2B N N 3/19 N N 3/79 3RP15 40-1BN EAR99 N 7/34 3RT10 15-2H 3RP15 40-2A N N 7/35 3RT10 15-2J N N 3/79 3RP15 40-2BB N N 7/35 3RT10 15-2K N N 3/79 3RP15 40-2BJ N N 7/35 3RT10 15-2M N N 3/80 3RP15 40-2BN EAR99 N 7/35 3RT10 15-2V N N 3/80 3RP15 55-1AP EAR99 N 7/34 3RT10 15-2W N N 3/80 3RP15 55-1AQ N N 7/34 3RT10 16-1A N N 3/15 3RP15 55-1AR N N 7/34 3RT10 16-1B N N 3/19 3RP15 55-2AP EAR99 N 7/35 3RT10 16-1H N N 3/79 3RP15 55-2AQ N N 7/35 3RT10 16-1J N N 3/79 N N 3/79 3RP15 55-2AR N N 7/35 3RT10 16-1K 3RP15 60-1SP EAR99 N 7/34 3RT10 16-1M N N 3/80 3RP15 60-1SQ N N 7/34 3RT10 16-1V N N 3/80 3RP15 60-2 EAR99 N 7/35 3RT10 16-1W N N 3/80 3RP15 74-1NM N N 7/34 3RT10 16-2A N N 3/15 3RP15 74-1NP EAR99 N 7/34 3RT10 16-2B N N 3/19 3RP15 74-1NQ N N 7/34 3RT10 16-2H N N 3/79 3RP15 74-2NM N N 7/35 3RT10 16-2J N N 3/79 3RP15 74-2NP EAR99 N 7/35 3RT10 16-2K N N 3/79 3RP15 76 N N 7/34 ... 35 3RT10 16-2M N N 3/80 N N 3/80 3RP19 01 N N 7/36, 7/40 3RT10 16-2V 3RP19 02 N N 2/15, 2/50, 6/8, 7/36, 7/46, 7/48, 7/50, 7/52, 7/54, 7/59, 7/62, 7/65, 7/79, 7/84 3RT10 16-2W N N 3/80 3RT10 17-1A N N 3/15 3RT10 17-1B N N 3/19 3RT10 17-1H N N 3/79 Siemens LV 1 · 2008 20 Order No. 20/49 LV1_20.book Seite 50 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings 20 Order No. Export markings Page Order No. Export markings Page ECCN AL ECCN AL 3RT10 17-1J N N 3/79 3RT10 36-1X N N 3/63 3RT10 17-1K N N 3/79 3RT10 36-3A N N 3/17 3RT10 17-1M N N 3/80 3RT10 36-3B N N 3/21 3RT10 17-1V N N 3/80 3RT10 36-3K N N 3/62 3RT10 17-1W N N 3/80 3RT10 36-3X N N 3/63 3RT10 17-2A N N 3/15 3RT10 44-1A N N 3/18 3RT10 17-2B N N 3/19 3RT10 44-1B N N 3/21 3RT10 17-2H N N 3/79 3RT10 44-1X N N 3/63 3RT10 17-2J N N 3/79 3RT10 44-3A N N 3/18 3RT10 17-2K N N 3/62, 3/79 3RT10 44-3B N N 3/21 3RT10 17-2M N N 3/80 3RT10 44-3K N N 3/62 3RT10 17-2V N N 3/80 3RT10 44-3X N N 3/63 3RT10 17-2W N N 3/80 3RT10 45-1A N N 3/18 3RT10 23-1A N N 3/16 3RT10 45-1B N N 3/21 3RT10 23-1B N N 3/20 3RT10 45-1X N N 3/63 3RT10 23-3A N N 3/16 3RT10 45-3A N N 3/18 3RT10 23-3B N N 3/20 3RT10 45-3B N N 3/21 3RT10 24-1A N N 3/16 3RT10 45-3K N N 3/62 3RT10 24-1B N N 3/20 3RT10 45-3X N N 3/63 3RT10 24-1K N N 3/81 3RT10 46-1A N N 3/18 3RT10 24-3A N N 3/16 3RT10 46-1B N N 3/21 3RT10 24-3B N N 3/20 3RT10 46-1X N N 3/63 3RT10 24-3K N N 3/81 3RT10 46-3A N N 3/18 3RT10 25-1A N N 3/16 3RT10 46-3B N N 3/21 3RT10 25-1B N N 3/20 3RT10 46-3K N N 3/62 3RT10 25-1K N N 3/81 3RT10 46-3X N N 3/63 3RT10 25-1X N N 3/63 3RT10 54-1A N N 3/22 3RT10 25-3A N N 3/16 3RT10 54-1N N N 3/23 3RT10 25-3B N N 3/20 3RT10 54-1P N N 3/24 3RT10 25-3K N N 3/62, 3/81 3RT10 54-1QF EAR99 N 3/24 3RT10 25-3X N N 3/63 3RT10 54-1QP N N 3/24 3RT10 26-1A N N 3/16 3RT10 54-3 N N 3/22 ... 23 3RT10 26-1B N N 3/20 3RT10 55-2 N N 3/22 ... 23 3RT10 26-1K N N 3/81 3RT10 55-6A N N 3/22 3RT10 26-1X N N 3/63 3RT10 55-6N N N 3/23 3RT10 26-3A N N 3/16 3RT10 55-6P N N 3/24 3RT10 26-3B N N 3/20 3RT10 55-6QF EAR99 N 3/24 3RT10 26-3K N N 3/62, 3/81 3RT10 55-6QP N N 3/24 3RT10 26-3X N N 3/63 3RT10 56-2 N N 3/22 ... 23 3RT10 34-1A N N 3/17 3RT10 56-6A N N 3/22 3RT10 34-1B N N 3/21 3RT10 56-6N N N 3/23 3RT10 34-1X N N 3/63 3RT10 56-6P N N 3/24 3RT10 34-3A N N 3/17 3RT10 56-6QF EAR99 N 3/24 3RT10 34-3B N N 3/21 3RT10 56-6QP N N 3/24 3RT10 34-3K N N 3/62 3RT10 6 N N 3/22 ... 24 3RT10 34-3X N N 3/63 3RT10 7 N N 3/22 ... 24 3RT10 35-1A N N 3/17 3RT12 N N 3/26 3RT10 35-1B N N 3/21 3RT13 16-1A N N 3/52 3RT10 35-1X N N 3/63 3RT13 16-1B N N 3/53 3RT10 35-3A N N 3/17 3RT13 16-2A N N 3/52 3RT10 35-3B N N 3/21 3RT13 16-2B N N 3/53 3RT10 35-3K N N 3/62 3RT13 17-1A N N 3/52 3RT10 35-3X N N 3/63 3RT13 17-1B N N 3/53 3RT10 36-1A N N 3/17 3RT13 17-2A N N 3/52 3RT10 36-1B N N 3/21 3RT13 17-2B N N 3/53 20/50 Siemens LV 1 · 2008 LV1_20.book Seite 51 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Order No. Export markings Page Order No. Export markings Page ECCN AL ECCN AL 3RT13 25-1A N N 3/52 3RT19 24-5AN62 EAR99 N 3/114 3RT13 25-1B N N 3/53 3RT19 24-5AP N N 3/114 3RT13 26-1A N N 3/52 3RT19 24-5AR N N 3/114 3RT13 26-1B N N 3/53 3RT19 24-5AV N N 3/114 3RT13 36-1A N N 3/52 3RT19 26-1 N N 3/107 ... 108, 3/110, 6/49 3RT13 36-1B N N 3/53 3RT19 26-2C N N 3/106, 7/42 3RT13 44-1A N N 3/52 3RT19 26-2D N N 3/106, 7/42 3RT13 44-1B N N 3/53 3RT19 26-2E N N 3/105, 7/41 3RT13 46-1A N N 3/52 3RT19 26-2F N N 3/105 3RT13 46-1B N N 3/53 3RT19 26-2G N N 3/105 3RT14 46-1A N N 3/50 3RT19 26-2P N N 3/106 3RT14 46-1B N N 3/50 3RT19 26-3 N N 3/106 3RT14 56-6A N N 3/51 3RT19 26-4B N N 3/47, 3/111 3RT14 56-6N N N 3/51 3RT19 26-4C N N 3/47 3RT14 56-6P N N 3/51 3RT19 26-4M N N 3/112 3RT14 56-6Q EAR99 N 3/51 3RT19 26-4P N N 3/111 3RT14 6 N N 3/51 3RT19 26-4R N N 3/110, 6/50 3RT14 7 N N 3/51 3RT19 34-5 N N 3/114 ... 115 3RT15 16-1A N N 3/57 3RT19 34-6 N N 3/118 3RT15 16-1B N N 3/57 3RT19 35-5 N N 3/114 3RT15 16-2A N N 3/57 3RT19 35-6 N N 3/118 3RT15 16-2B N N 3/57 3RT19 36-1 N N 3/108, 6/49 3RT15 17-1A N N 3/57 3RT19 36-4B N N 3/47, 3/111 3RT15 17-1B N N 3/57 3RT19 36-4E N N 3/112, 5/26, 5/51, 5/56, 6/8, 6/16 3RT15 17-2A N N 3/57 3RT19 36-6 N N 3/118 3RT15 17-2B N N 3/57 3RT19 36-7 N N 3/118 3RT15 26-1A N N 3/57 3RT19 44-5AB N N 3/115 3RT15 26-1B N N 3/57 3RT19 44-5AC N N 3/115 3RT15 35-1A N N 3/57 3RT19 44-5AD N N 3/115 3RT15 35-1B N N 3/57 3RT19 44-5AF N N 3/115 3RT16 N N 3/58 3RT19 44-5AG N N 3/115 3RT19 00-1SB1 N N 3/113, 4/4, 5/57 3RT19 44-5AH N N 3/115 3RT19 00-1SB2 N N 3/113, 4/4, 5/57, 6/9, 6/126, 7/36, 7/40, 7/46, 7/48, 7/50, 7/52, 7/54, 7/59, 7/62, 7/65, 7/68, 7/70, 7/74 3RT19 44-5AK N N 3/115 3RT19 44-5AL N N 3/115 3/113, 4/4, 5/57, 6/9 3RT19 44-5AN2 N N 3/115 3/113, 4/4, 5/57, 6/9 3RT19 44-5AN61 N N 3/115 3/110, 6/50 3RT19 44-5AN62 EAR99 N 3/115 3/107 ... 109, 6/49 3RT19 44-5AP N N 3/115 N N 3/115 3RT19 00-1SB6 3RT19 00-1SD 3RT19 00-4 3RT19 16-1 N N N N N N N N 3RT19 16-2 N N 3/105 ... 106, 7/41 ... 42 3RT19 44-5AR 3RT19 16-4B N N 3/47, 3/111, 3/123 3RT19 44-5AV N N 3/115 3RT19 16-4J N N 3/113 3RT19 44-5B N N 3/115 3RT19 16-4K N N 3/110 ... 111 3RT19 44-6 N N 3/118 3/112 3RT19 45-5 N N 3/115 3/110, 6/50 3RT19 45-6 N N 3/118 3/39 3RT19 46-4B N N 3/47, 3/111 3/114 3RT19 46-4E N N 3/112, 5/26, 5/51, 5/56, 6/8, 6/16 3/114 3RT19 46-4F N N 3/110, 5/27, 6/16 3/114 3RT19 46-4G N N 5/27 N N 3/118 3RT19 16-4M 3RT19 16-4R 3RT19 22 3RT19 24-5AB 3RT19 24-5AC 3RT19 24-5AD N N N N N N N N N N N N N N 3/114 3RT19 24-5AG N N 3/114 3RT19 46-7 N N 3/118 3RT19 24-5AH N N 3/114 3RT19 54-6 N N 3/118 3RT19 24-5AK N N 3/114 3RT19 54-7 N N 3/118 3/114 3RT19 55-4 N N 3/112, 5/51, 6/16, 6/26, 7/12 3/114 3RT19 55-5A N N 3/116 3/114 3RT19 55-5N N N 3/117 3RT19 24-5AL 3RT19 24-5AN2 3RT19 24-5AN61 N N N N N N Siemens LV 1 · 2008 20 3RT19 24-5AF 3RT19 46-6 20/51 LV1_20.book Seite 52 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings 20 Order No. Export markings Page Order No. Export markings Page ECCN AL ECCN AL 3RT19 55-5P N N 3/117 3RV19 02-1AF N N 5/20 3RT19 55-5QF EAR99 N 3/117 3RV19 02-1AM N N 5/20 3RT19 55-5QP N N 3/117 3RV19 02-1AP N N 5/20, 6/48 3RT19 55-6 N N 3/118 3RV19 02-1AS N N 5/20 3RT19 55-7 N N 3/118 3RV19 02-1AV N N 5/20 3RT19 56-1 N N 3/108 3RV19 02-1D N N 5/20, 6/48 3RT19 56-4B N N 3/47, 3/111 3RV19 03 N N 5/32 3RT19 56-4E N N 3/112, 5/51, 6/16, 6/27, 7/12 3RV19 08 N N 5/26 3RT19 56-4G N N 3/112, 5/51, 6/16, 6/26, 7/12 3RV19 12 N N 5/20 3RT19 56-6 N N 3/118 3RV19 13 N N 5/31 ... 32 3RT19 56-7 N N 3/118 3RV19 15-1 N N 5/22 3RT19 64-6A N N 3/118 3RV19 15-2 N N 5/22 3RT19 64-6V N N 3/118 3RV19 15-3 N N 5/22 3RT19 64-7 N N 3/118 3RV19 15-5 N N 3/47, 5/22 3RT19 65-5 N N 3/116 ... 117 3RV19 15-6 N N 5/23 3RT19 65-6A N N 3/118 3RV19 17-1 N N 6/56 3RT19 65-6V N N 3/118 3RV19 17-4 N N 6/56 3RT19 65-7 N N 3/118 3RV19 17-5 N N 6/56 ... 57 3RT19 66-1 N N 3/109 3RV19 17-6 N N 6/57 3RT19 66-4B N N 3/47, 3/111 3RV19 17-7 N N 6/56 ... 57 3RT19 66-4E N N 3/112, 5/51, 6/16, 6/27, 7/12 3RV19 18 N N 5/27 3RT19 66-4G N N 3/112, 5/51, 6/16, 6/26, 7/12 3RV19 21 N N 5/19 3RT19 66-5 N N 3/116 ... 117 3RV19 22 N N 5/20 3RT19 66-6A N N 3/118 3RV19 23 N N 5/31 ... 32 3RT19 66-6D N N 3/118 3RV19 25 N N 5/22 3RT19 66-6V N N 3/118 3RV19 26 N N 5/25 3RT19 66-7 N N 3/118 3RV19 27 N N 6/56 3RT19 75-5 N N 3/116 ... 117 3RV19 28 N N 5/19, 5/27 3RT19 75-6A N N 3/118 3RV19 33 N N 5/31 3RT19 75-6V N N 3/118 3RV19 35-1 N N 3/47, 5/22 3RT19 75-7 N N 3/118 3RV19 35-3 N N 5/22 3RT19 76-6A N N 3/118 3RV19 35-5 N N 3/47, 5/22 3RT19 76-6D N N 3/118 3RV19 35-6 N N 5/23 3RT19 76-6V N N 3/118 3RV19 36-2 N N 5/25 3RT19 76-7 N N 3/118 3RV19 36-3 N N 5/25 3RU11 N N 5/53 ... 55 3RV19 38 EAR99 N 5/19 3RU19 00-1 N N 5/50, 5/56, 6/16 3RV19 46-2 N N 5/25 3RU19 00-2 N N 5/56, 6/16 3RV19 46-3 N N 5/25 3RU19 1 N N 5/56 3RW2 N N 7/18 3RU19 2 N N 5/56 3RW30 0 on req. 6/6 3RU19 3 N N 5/56 3RW30 1 on req. 6/6 3RU19 4 EAR99 N 5/56 3RW30 24 on req. 6/6 3RV10 N N 5/6 ... 9 3RW30 25 on req. 3RV11 N N 5/10 3RW30 26-1AA EAR99 3RV13 N N 5/11 3RW30 26-1AB on req. 3RV14 N N 5/12 3RW30 34 on req. 3RV16 11-0 N N 5/13 3RW30 35-1AA N 3RV16 11-1 N N 5/16 3RW30 35-1AB on req. 6/6 3RV17 N N 5/14 3RW30 36 on req. 6/6 3RV18 N N 5/15 3RW30 44 on req. 3RV19 01-0 N N 5/18 3RW30 45-1AA EAR99 3RV19 01-1 N N 5/13, 5/16, 5/18, 6/48 3RW30 45-1AB on req. 3RV19 01-2 N N 5/18 3RW30 46 on req. 3RV19 02-1AB0 N N 5/20 3RW31 N N 6/7 3RV19 02-1AB4 N N 5/20 3RW39 N N 6/8 20/52 Siemens LV 1 · 2008 6/6 N 6/7 6/6 6/6 N 6/7 6/6 N 6/7 6/6 6/6 LV1_20.book Seite 53 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Export markings Page Order No. Export markings Page ECCN AL ECCN AL 3RW40 N N 6/13 ... 15 3SB30 00-0E N N 5/50, 5/56, 6/16, 9/26 3RW44 N N 6/21 ... 25 3SB30 00-1 N N 9/31, 9/35 3RW49 00-0A N N 6/26 3SB30 00-2 N N 9/32 3RW49 00-0K N N 1/8, 6/26 3SB30 00-3 N N 9/33 ... 34 3RW49 00-0PB0 N N 6/16 3SB30 00-4 N N 9/33 ... 34 3RW49 00-0PB1 EAR99 N 6/16 3SB30 00-5 N N 9/33 ... 34 3RW49 2 EAR99 N 6/17 3SB30 00-7 N N 9/36 3RW49 3 N N 6/17, 6/27 3SB30 01 N N 9/30 ... 32, 9/36 3RW49 47-8VB EAR99 N 6/17 3SB31 N N 9/36 ... 37, 9/40 ... 43 3RW49 47-8VX N N 6/17, 6/27 3SB32 N N 9/20 ... 26 3RW49 5 N N 6/27 3SB33 N N 9/38 ... 39 3RW49 6 EAR99 N 6/27 3SB34 00-0 N N 9/59, 16/42 3RW4c on req. 6/13 3SB34 00-1 N N 9/59 ... 60 3RX1 N N 6/127 3SB34 00-2 N N 9/60 3RX8 N N 2/38, 2/43, 2/61, 2/64 ... 65, 6/64, 6/127, 8/42, 8/48, 8/54 3SB34 00-3 N N 9/60 3SB34 03-0 N N 9/61 3SB34 03-1 N N 9/61 3SB34 11-0 N N 9/62 3SB34 11-1 N N 9/62 3SB34 20-0 N N 9/88 3SB34 20-1 N N 9/88 3SB34 23-0 N N 9/89 3SB34 23-1 N N 9/89 3SB34 23-2 N N 9/89 3SB35 00-0 N N 9/49 3SB35 00-1 N N 9/50, 9/57 3SB35 00-2D N N 9/53 3RX90 10 N N 2/59 3RX90 12 N N 2/59 3RX90 13 N N 2/59 3RX90 14 N N 2/59 3RX90 15 N N 2/59 3RX90 16 N N 2/59 3RX90 17 N N 2/59 3RX90 2 N N 2/59 3RX95 N N 2/58 3RX98 N N 2/43, 2/51, 2/60, 2/64 ... 65, 6/64, 6/121, 6/123 ... 124, 6/126 ... 127 3S 3SB10 N N 9/26 3SB35 00-2E N N 9/53 3SB12 N N 9/27 ... 28 3SB35 00-2F N N 9/54 3SB14 N N 9/29, 17/11, 17/36 ... 37, 17/42 ... 43 3SB35 00-2G N N 9/54 3SB19 N N 9/29, 9/67, 9/71 ... 73, 9/76 ... 80, 9/82, 9/91, 9/93 3SB35 00-2H N N 9/51 3SB35 00-2K N N 9/51 3SB20 N N 9/7 ... 8 3SB35 00-2L N N 9/52 3SB22 N N 9/5 ... 6 3SB35 00-2P EAR99 N 9/51 3SB23 N N 9/9 3SB35 00-2Q EAR99 N 9/52 3SB24 04-0 N N 9/9 3SB35 00-2S EAR99 N 9/53 3SB24 04-3 N N 9/9 3SB35 00-2T EAR99 N 9/54 3SB24 5 N N 9/10 3SB35 00-2U EAR99 N 9/54 3SB29 01 N N 9/11 ... 15 3SB35 00-2V EAR99 N 9/54 3SB29 02 N N 9/15, 9/17 3SB35 00-3A N N 9/55 3SB29 08-0 N N 9/9 ... 10 3SB35 00-3B N N 9/55 3SB29 08-1 N N 9/16, 9/77 3SB35 00-3D N N 9/56 3SB29 08-2 N N 9/16 ... 17, 9/77 3SB35 00-3E N N 9/56 3SB29 08-3 N N 9/17 3SB35 00-3G N N 9/56 3SB29 08-8AA N N 9/17 3SB35 00-3P EAR99 N 9/51 3SB29 08-8AB N N 9/17 3SB35 00-3Q EAR99 N 9/52 3SB29 08-8AD EAR99 N 9/17 3SB35 00-3S EAR99 N 9/53 3SB29 08-8AE N N 9/17 3SB35 00-3T EAR99 N 9/54 3SB29 1 N N 9/16 3SB35 00-3U EAR99 N 9/54 3SB30 00-0AA N N 9/30 3SB35 00-3V EAR99 N 9/54 3SB30 00-0AB N N 9/30 3SB35 00-4 N N 9/55 ... 56 3SB30 00-0AC on req. 9/30 3SB35 00-5 N N 9/55 ... 56 3SB30 00-0B N N 9/30 3SB35 01-0 N N 9/49 3SB30 00-0C N N 9/30 3SB35 01-1 N N 9/50 3SB30 00-0D N N 9/30 3SB35 01-2D N N 9/53 Siemens LV 1 · 2008 20 Order No. 20/53 LV1_20.book Seite 54 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Order No. Export markings Order No. Export markings Page ECCN AL ECCN AL 3SB35 01-2E N N 9/53 3SB38 01-2EA30 N N 9/85 3SB35 01-2F N N 9/54 3SB38 01-2EB N N 9/85 3SB35 01-2G N N 9/54 3SB38 01-2EC N N 9/86 3SB35 01-2K N N 9/51 3SB38 01-2EF N N 9/85 3SB35 01-2L N N 9/52 3SB38 01-2EG N N 9/85 3SB35 01-2P EAR99 N 9/51 3SB38 01-3 on req. 3SB35 01-2Q EAR99 N 9/52 3SB38 02-0AA N 3SB35 01-2S EAR99 N 9/53 3SB38 02-0AZ on req. 3SB35 01-2T EAR99 N 9/54 3SB38 02-0D N 3SB35 01-3 EAR99 N 9/51 ... 54 3SB38 02-1 on req. 3SB35 01-6 N N 9/58 3SB38 02-2AA N 3SB36 01-0 N N 9/44 ... 45 3SB38 02-2AZ on req. 3SB36 01-1 N N 9/46 3SB38 02-2D N 3SB36 01-2K N N 9/47 3SB38 02-3 on req. 3SB36 01-2P EAR99 N 9/47 3SB38 03-0AA N 3SB36 01-4 N N 9/47 3SB38 03-0AZ on req. 3SB36 02-0 N N 9/44 ... 45 3SB38 03-0D N 3SB36 02-2K N N 9/47 3SB38 03-1 on req. 3SB36 02-2P EAR99 N 9/47 3SB38 03-2AA N 3SB36 02-4 N N 9/47 3SB38 03-2AZ on req. 3SB36 03 N N 9/44 ... 46 3SB38 03-2D N 3SB36 04 N N 9/48 3SB38 03-3 on req. 3SB36 05-0AA0 -- 9/44 3SB38 04-0AA N 3SB36 05-0AA2 N N 9/44 ... 45 3SB38 04-0AZ on req. 3SB36 05-0AA3 N N 9/44 ... 45 3SB38 04-1 on req. 3SB36 05-0AA4 N N 9/44 ... 45 3SB38 04-2AA N 3SB36 05-0AA5 N N 9/44 ... 45 3SB38 04-2AZ on req. 3SB36 05-0AA6 N N 9/44 ... 45 3SB38 04-3 on req. 3SB36 05-0AA7 N N 9/44 ... 45 3SB38 06-0AA N 3SB36 06 N N 9/44 ... 45 3SB38 06-0AZ on req. 3SB36 07 N N 9/44 ... 45 3SB38 06-1 on req. 3SB36 08-2D N N 9/47 3SB38 06-2AA N 3SB36 08-2E N N 9/47 3SB38 06-2AZ on req. 3SB36 08-2S EAR99 N 9/47 3SB38 06-3 on req. 3SB36 08-2T EAR99 N 9/47 3SB38 6 N 3SB36 10-2D N N 9/47 3SB38 8 on req. 3SB36 10-2E N N 9/47 3SB39 01-0A N N 3SB36 10-2S EAR99 N 9/47 9/62, 9/81 ... 82, 9/88 ... 89, 9/93, 9/97 3SB36 10-2T EAR99 N 9/47 3SB39 01-0CB EAR99 N 9/82 3SB39 01-0CG N N 9/82 3SB39 01-0CH N N 9/80 3SB39 01-0CK N N 9/93 3SB39 01-0CL N N 9/93 3SB39 01-0CM N N 9/93 3SB39 01-0CN N N 9/93 3SB39 01-0CP N N 9/93 3SB39 01-0CQ EAR99 N 9/93 3SB39 01-0CS N N 9/93 3SB39 01-0CT N N 9/93 3SB39 01-0CU N N 9/93 3SB39 01-1 N N 9/16, 9/76 ... 77 3SB39 01-2 N N 9/66 3SB39 02 N N 9/66, 9/70 3SB39 03 N N 9/66, 9/72 3SB39 05 N N 9/66, 9/73 3SB36 11 N 3SB36 4 N 3SB36 5 N 3SB38 01-0AA 3SB38 01-0AB 3SB38 01-0AD 3SB38 01-0AZ 3SB38 01-0D N N N N N N N N on req. N 3SB38 01-1 3SB38 01-2AB 3SB38 01-2AD 3SB38 01-2AZ 3SB38 01-2D N N N N N 3SB38 01-2EA3 9/44 ... 45, 9/48 9/44 ... 45, 9/48 9/86 9/86 9/86 9/84 9/84 9/87 N N N on req. N 9/46 9/87 on req. 3SB38 01-2AA 20/54 N N 3SB38 01-0E 20 Page 9/86 9/86 9/86 9/87 N on req. Siemens LV 1 · 2008 9/85 9/86 9/87 N 9/86 9/87 N 9/84 9/87 N 9/86 9/87 N 9/85 9/87 N 9/86 9/87 N 9/84 9/87 N 9/86 9/87 N 9/85 9/87 N 9/86 9/87 9/87 N 9/86 9/87 9/87 N 9/86 9/87 9/87 N 9/86 9/87 9/87 N 9/97 9/87 LV1_20.book Seite 55 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Order No. Export markings Page Order No. Export markings Page ECCN AL ECCN AL 3SB39 06 N N 9/66, 9/90 3SE29 N N 9/103 3SB39 1 N N 9/77 3SE30 N N 8/41 3SB39 2 N N 9/37, 9/71 ... 73, 9/78 ... 82, 9/93 3SE31 N N 8/39 3SB39 30-0C N N 9/75 3SE39 N N 9/103 3SB39 30-0D N N 9/75 3SE50 00-0AA N N 3SB39 30-0EA1 N N 9/75 8/11, 8/15, 8/25, 8/29, 8/62, 8/66, 8/68 3SB39 30-0EA2 N N 9/75 3SE50 00-0AC EAR99 N 8/25, 8/29, 8/61, 8/68 3SE50 00-0AD02 EAR99 N 8/25, 8/29, 8/61, 8/68 3SE50 00-0AD03 N N 8/11, 8/15, 8/66 3SE50 00-0AD04 N N 8/11, 8/15, 8/66 3SE50 00-0AD1 N N 8/11, 8/15, 8/66 3SE50 00-0AE N N 8/11, 8/15, 8/25, 8/29, 8/61, 8/66, 8/68 3SE50 00-0AF N N 8/11, 8/15, 8/25, 8/29, 8/61, 8/66, 8/68 3SB39 30-0EA3 3SB39 30-0EA4 3SB39 30-0EA5 3SB39 30-0EA6 EAR99 N N N N N N N 9/75 9/75 9/75 9/75 N N 9/75 3SB39 30-0F N N 9/75 3SB39 30-0G N N 9/75 3SB39 30-0H N N 9/75 3SE50 00-0AH N N 8/25, 8/29, 8/62, 8/68 3SB39 30-6 N N 9/75 3SE50 00-0AK N N 8/11, 8/15, 8/66 3SB39 31 N N 9/81, 9/93 3SE50 00-0AR N N 8/11, 8/15, 8/25, 8/29, 8/61 3SB39 4 N N 9/68, 9/71 ... 72, 9/78 ... 80, 9/82 3SE50 00-0AT N N 8/25, 8/29, 8/62, 8/68 3SB39 5 N N 9/75, 9/81 3SE50 00-0AU N N 8/57 ... 58, 8/75 ... 76 3SE21 N N 8/30 ... 32, 8/36 3SE50 00-0AV N N 8/48, 8/54, 8/70 ... 71, 8/73 ... 74 N N 8/43 3SE22 0 N N 8/16 3SE50 00-0B 3SE22 10-3C N N 8/17 3SE50 00-0C N N 8/43 3SE22 10-3D N N 8/17 3SE50 00-0G N N 8/43 3SE22 10-3E N N 8/17 3SE50 00-0K N N 8/43 3SE22 10-3F N N 8/17 3SE50 00-0L N N 8/43 3SE22 10-3G N N 8/17 3SE50 00-0N N N 8/43 3SE22 10-3L EAR99 N 8/17 3SE51 10 N N 8/43 3SE22 10-3M EAR99 N 8/17 3SE51 12-0BA N N 8/24, 8/61 3SE22 10-3S N N 8/17 3SE51 12-0BC N N 8/22 3SE22 10-3U N N 8/17 3SE51 12-0BD EAR99 N 8/22 N N 8/22 3SE22 10-3V N N 8/17 3SE51 12-0BE 3SE22 10-3W N N 8/17 3SE51 12-0BF N N 8/22 3SE22 30-0 N N 8/19 ... 20 3SE51 12-0BH N N 8/23 3SE22 30-1 N N 8/19 ... 20 3SE51 12-0CA N N 8/24, 8/61 3SE22 30-3 N N 8/19 ... 20 3SE51 12-0CC N N 8/22, 8/60 3SE22 30-6 N N 8/19 ... 20 3SE51 12-0CD02 EAR99 N 8/22 3SE22 30-7A N N 8/20 3SE51 12-0CD02-1 N N 8/60 3SE22 30-7C N N 8/19 3SE51 12-0CE N N 8/22, 8/60 3SE22 30-7D N N 8/19 3SE51 12-0CF N N 8/22, 8/60 3SE22 30-7E N N 8/19 3SE51 12-0CH N N 8/23, 8/60 N N 8/22, 8/60 3SE22 30-7F N N 8/19 3SE51 12-0CR 3SE22 30-7G N N 8/20 3SE51 12-0CT N N 8/23, 8/60 3SE22 30-7U N N 8/20 3SE51 12-0KA N N 8/24, 8/61 3SE22 30-7V EAR99 N 8/20 3SE51 12-0KC N N 8/22 3SE22 30-7W N N 8/20 3SE51 12-0KD EAR99 N 8/22 3SE22 30-8 N N 8/19 ... 20 3SE51 12-0KE N N 8/22 3SE22 4 N N 8/49 3SE51 12-0KH N N 8/23 3SE22 5 N N 8/49 3SE51 12-0LA N N 8/24, 8/61 3SE22 83-0 N N 8/59 3SE51 12-0LC N N 8/22 3SE22 83-6GA43 N N 8/59 3SE51 12-0LD EAR99 N 8/22 N N 8/22 3SE22 83-6GA44 on req. 8/59 3SE51 12-0LE 3SE22 83-6GA5 N N 8/59 3SE51 12-0LF N N 8/22 3SE23 EAR99 N 8/33 ... 34, 8/36 3SE51 12-0LH N N 8/23 3SE24 N N 8/35 ... 36 3SE51 12-0LU N N 8/58, 8/63 3SE28 N N 8/55 3SE51 12-0Q N N 8/47, 8/63 Siemens LV 1 · 2008 20 3SB39 30-0EA7 20/55 LV1_20.book Seite 56 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Order No. Export markings Page Order No. Page ECCN AL ECCN AL 3SE51 12-1 N N 8/24, 8/47 3TC44 17-0L N N 3/65 3SE51 12-3 N N 8/24, 8/47 3TC48 17-0A N N 3/67 3SE51 14 N N 8/22 ... 24, 8/47 3TC48 17-0B N N 3/67 3SE51 15 N N 8/24, 8/47 3TC48 17-0L N N 3/65 3SE51 20 N N 8/43 3TC52 17-0A N N 3/67 3SE51 22-0B N N 8/26 ... 28, 8/61 3TC52 17-0B N N 3/67 3SE51 22-0C N N 8/26 ... 28, 8/60 ... 61 3TC52 17-0L N N 3/65 3SE51 22-0KA N N 8/28, 8/61 3TC56 17-0A N N 3/67 3SE51 22-0KC N N 8/26 3TC56 17-0B N N 3/67 3SE51 22-0KD EAR99 N 8/26 3TC56 17-0L N N 3/65 3SE51 22-0KE N N 8/26 3TC74 14-0 N N 3/68 3SE51 22-0KH N N 8/27 3TC74 14-1 N N 3/68 3SE51 22-0LA N N 8/28, 8/61 3TC78 14-0 N N 3/68 3SE51 22-0LC N N 8/26 3TC78 14-1 N N 3/68 3SE51 22-0LD EAR99 N 8/26 3TD N N 3/48 3SE51 22-0LE N N 8/26 3TE N N 3/49 3SE51 22-0LH N N 8/27 3TF20 01-0A N N 3/30 3SE51 22-0Q N N 8/47, 8/63 3TF20 01-0B N N 3/30 3SE51 22-1 N N 8/28, 8/47 3TF20 01-3A N N 3/30 3SE51 22-3 N N 8/28, 8/47 3TF20 01-3B N N 3/30 3SE52 30 N N 8/43 3TF20 01-6A N N 3/30 3SE52 32 N N 8/8 ... 10, 8/46, 8/57 3TF20 01-6B N N 3/30 3SE52 34 N N 8/8 ... 10, 8/46 3TF20 01-7A N N 3/30 3SE52 40 N N 8/43 3TF20 01-7B N N 3/30 3SE52 42 N N 8/12 ... 14, 8/46 3TF20 10-0A N N 3/30 3SE52 50-0A N N 8/40 3TF20 10-0B N N 3/30 3SE52 50-0B N N 8/40 3TF20 10-3A N N 3/30 3SE52 50-0C N N 8/40 3TF20 10-3B N N 3/30 3SE52 50-0K N N 8/40 3TF20 10-6A N N 3/30 3SE52 50-0L N N 8/40 3TF20 10-6B N N 3/30 3SE53 N N 8/52 ... 53 3TF20 10-7A N N 3/30 3SE6 N N 8/86 3TF20 10-7B N N 3/30 3SE7 N N 9/98 ... 100 3TF22 11-0A N N 3/31 3SF11 N N 8/67, 8/71, 8/76 3TF22 11-0B N N 3/31 3SF12 N N 8/65, 8/70, 8/75 3TF22 22-0A N N 3/31 3SF13 14-1SB N N 8/74 3TF22 22-0B N N 3/31 3SF13 14-1SD N N 8/74 3TF28 01-0A N N 3/30 3SF13 14-1SE EAR99 N 8/74 3TF28 01-0B N N 3/30 3SF13 14-1SF N N 8/74 3TF28 10-0A N N 3/30 3SF13 14-1SG N N 8/74 3TF28 10-0B N N 3/30 3SF13 14-1SJ N N 8/74 3TF29 11-0A N N 3/31 3SF13 2 N N 8/73 3TF29 11-0B N N 3/31 3SF2 N N 9/101 3TF29 22-0A N N 3/31 3SF5 N N 9/63, 9/95 ... 96 3TF29 22-0B N N 3/31 3SF6 N N 6/102 3TF68 33-1D N N 3/27 3SF7 N N 6/102 3TF68 33-1Q N N 3/27 3SR N N 9/76 3TF68 33-8D N N 3/27 3SX1 N N 5/50, 5/56, 6/16, 9/76, 9/82 3TF68 33-8Q N N 3/27 3SX3 N N 8/18, 8/21, 8/37 ... 38, 8/49, 8/55, 8/59, 8/86, 9/99 3TF68 4 N N 3/27 3TF69 33-1D N N 3/27 3TF69 33-1Q N N 3/27 3TF69 33-8D N N 3/27 3TF69 33-8Q N N 3/27 3TF69 4 N N 3/27 3TG10 01-0A N N 3/96 3SX9 N N 8/42, 8/48, 8/54 3SY N N 8/38, 8/41 ... 42, 8/48, 8/54, 9/77 3T 20 Export markings 3TB N N 3/29, 3/64 3TC44 17-0A N N 3/67 3TC44 17-0B N N 3/67 20/56 Siemens LV 1 · 2008 LV1_20.book Seite 57 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Export markings Page Order No. Export markings Page ECCN AL ECCN AL 3TG10 01-0B N N 3/96 3TH42 62-0L N N 3/60 3TG10 01-1A N N 3/96 3TH42 71-0A N N 3/73 3TG10 01-1B N N 3/96 3TH42 71-0B N N 3/73 3TG10 10-0A N N 3/96 3TH42 80-0A N N 3/73 3TG10 10-0B N N 3/96 3TH42 80-0B N N 3/73 3TG10 10-1A N N 3/96 3TH42 93-0A N N 3/73 3TG10 10-1B N N 3/96 3TH42 93-0B N N 3/73 3TH20 22-0A N N 3/76 3TH43 10-0A N N 3/74 3TH20 22-0B N N 3/76 3TH43 10-0B N N 3/74 3TH20 22-3A N N 3/76 3TH43 46-0A N N 3/74 3TH20 22-3B N N 3/76 3TH43 46-0B N N 3/74 3TH20 22-6A N N 3/76 3TH43 55-0A N N 3/74 3TH20 22-6B N N 3/76 3TH43 55-0B N N 3/74 3TH20 22-7A N N 3/76 3TH43 64-0A N N 3/74 3TH20 22-7B N N 3/76 3TH43 64-0B N N 3/74 3TH20 31-0A N N 3/76 3TH43 73-0A N N 3/74 3TH20 31-0B N N 3/76 3TH43 73-0B N N 3/74 3TH20 31-3A N N 3/76 3TH43 82-0A N N 3/74 3TH20 31-3B N N 3/76 3TH43 82-0B N N 3/74 3TH20 31-6A N N 3/76 3TH43 91-0A N N 3/74 3TH20 31-6B N N 3/76 3TH43 91-0B N N 3/74 3TH20 31-7A N N 3/76 3TH43 94-0A N N 3/74 3TH20 31-7B N N 3/76 3TH43 94-0B N N 3/74 3TH20 40-0A N N 3/76 3TK10 N N 3/54 3TH20 40-0B N N 3/76 3TK11 N N 3/54 3TH20 40-3A N N 3/76 3TK12 N N 3/54 3TH20 40-3B N N 3/76 3TK13 N N 3/54 3TH20 40-6A N N 3/76 3TK14 N N 3/54 3TH20 40-6B N N 3/76 3TK15 N N 3/54 3TH20 40-7A N N 3/76 3TK17 N N 3/54 3TH20 40-7B N N 3/76 3TK19 1 N N 3/130 3TH22 44-0A N N 3/76 3TK19 2 N N 3/130 3TH22 44-0B N N 3/76 3TK19 3 N N 3/130 3TH22 53-0A N N 3/76 3TK19 4 N N 3/130 3TH22 53-0B N N 3/76 3TK19 5 N N 3/130 3TH22 62-0A N N 3/76 3TK19 6 N N 3/130 3TH22 62-0B N N 3/76 3TK19 7 on req. 3TH22 71-0A N N 3/76 3TK20 22-0A N N 3/55 3TH22 71-0B N N 3/76 3TK20 22-0B N N 3/55 3TH22 80-0A N N 3/76 3TK20 22-3A N N 3/55 3TH22 80-0B N N 3/76 3TK20 22-3B N N 3/55 3TH27 22-0A N N 3/77 3TK20 22-6A N N 3/55 3TH27 22-0B N N 3/77 3TK20 22-6B N N 3/55 3TH27 31-0A N N 3/77 3TK20 22-7A N N 3/55 3TH27 31-0B N N 3/77 3TK20 22-7B N N 3/55 3TH27 40-0A N N 3/77 3TK20 31-0A N N 3/55 3TH27 40-0B N N 3/77 3TK20 31-0B N N 3/55 3TH42 44-0A N N 3/73 3TK20 31-3A N N 3/55 3TH42 44-0B N N 3/73 3TK20 31-3B N N 3/55 3TH42 44-0L N N 3/60 3TK20 31-6A N N 3/55 3TH42 53-0A N N 3/73 3TK20 31-6B N N 3/55 3TH42 53-0B N N 3/73 3TK20 31-7A N N 3/55 3TH42 53-0L N N 3/60 3TK20 31-7B N N 3/55 3TH42 62-0A N N 3/73 3TK20 40-0A N N 3/55 3TH42 62-0B N N 3/73 3TK20 40-0B N N 3/55 3/130 Siemens LV 1 · 2008 20 Order No. 20/57 LV1_20.book Seite 58 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings 20 Order No. Export markings Page Order No. Export markings Page ECCN AL ECCN AL 3TK20 40-3A N N 3/55 3TY27 40 N N 3/129 3TK20 40-3B N N 3/55 3TY27 41 N N 3/129 3TK20 40-6A N N 3/55 3TY27 42 N N 3/129 3TK20 40-6B N N 3/55 3TY27 8 N N 3/129 3TK20 40-7A N N 3/55 3TY64 43-0B on req. 3TK20 40-7B N N 3/55 3TY64 43-0L N 3TK28 1 N N 7/88 3TY64 83-0A on req. 3TK28 21 N N 7/82 ... 83 3TY64 83-0B on req. 3TK28 22 N N 7/82 ... 83 3TY64 83-0L N N 3/121 3TK28 23 N N 7/82 ... 83 3TY65 00 N N 3/127 3TK28 24 N N 7/82 ... 83 3TY65 01 N N 3/127 ... 128 3TK28 25 N N 7/82 ... 83 3TY65 02 N N 3/127 3TK28 26-0 N N 7/84 3TY65 03-0B on req. 3TK28 26-1 N N 7/82 3TY65 03-0L N N 3/121 3TK28 26-2 N N 7/83 3TY65 20 N N 3/127 3TK28 27 N N 7/82 ... 83 3TY65 22 N N 3/127 3TK28 28 N N 7/82 ... 83 3TY65 23-0A on req. 3TK28 3 N N 7/82 ... 83 3TY65 23-0B on req. 3TK28 40 N N 7/77 ... 78 3TY65 23-0L N N 3/121 3TK28 41 N N 7/77 ... 78 3TY65 40 N N 3/127 3TK28 42 N N 7/77 ... 78 3TY65 42 N N 3/127 3TK28 45 N N 7/77 ... 78 3TY65 43-0B on req. 3TK28 5 N N 7/86 3TY65 43-0L N N 3/121 3TX2 N N 3/129 3TY65 60 N N 3/127 3TX40 N N 3/124 3TY65 61 N N 3/127 ... 128 3TX41 N N 3/124 3TY65 62 N N 3/127 3TX42 N N 3/124, 9/80 3TY65 63-0B on req. 3TX44 0 N N 3/121, 3/125 3TY65 63-0L N 3TX44 1 N N 3/121, 3/125 3TY65 66 on req. 3TX44 2 N N 3/121, 3/125 3TY74 on req. 3TX44 3 N N 3/121, 3/125 3TY75 N N 3/120, 3/129 3TX44 4 N N 3/121, 3/125 3TY76 80 N N 3/129 3TX44 90 N N 3/121 ... 122, 3/125 ... 126 3TY76 81 N N 3/129 3TX44 91-2A EAR99 N 3/122, 3/126 3TY76 83-0C on req. 3TX44 91-2K N N 3/122 3TY76 83-0D on req. 3TX47 N N 3/125, 16/40 ... 41 3TY76 83-0Q N N 3/130 3TX6 N N 3/120, 17/68, 19/111 3TY76 84 N N 3/130 3TX70 0 N N 3/82 ... 83, 3/86 ... 87, 3/92, 3/94 3TY76 90 N N 3/129 3TX70 1 N N 3/84 ... 85 3TY76 93-0C on req. 3TX70 9 N N 3/120 3TY76 93-0D on req. 3TX74 N N 3/119, 3/124, 6/10, 7/19 3TY76 93-0Q N N 3/130 3TX75 N N 3/112, 3/119 ... 120, 7/18 ... 19 3U 3UF18 N N 7/19 3TX76 80-0D N N 3/120 3UF19 00-1D N N 7/18 3TX76 80-0E N N 3/120 3UF19 00-1E N N 7/18 3TX76 86 N N 3/120, 7/18 ... 19 3UF19 00-1K N N 7/18 3TX76 9 N N 3/120, 7/18 ... 19 3UF19 00-1M EAR99 N 7/18 3TY24 40 N N 3/128 3UF19 00-1N N N 7/18 3TY24 42 N N 3/121, 3/128 3UF19 00-1P N N 7/18 3TY24 80 N N 3/128 3UF50 on req. 3TY24 82 N N 3/128 3UF51 N N 7/16 3TY25 20 N N 3/128 3UF52 N N 7/16 3TY25 22 N N 3/128 3UF57 00-0AA00-0 EAR99 N 7/17 3TY25 60 N N 3/128 3UF57 00-0AA00-1 N N 7/17 3TY25 62 N N 3/128 3UF57 1 5D992B1 N 7/17 20/58 Siemens LV 1 · 2008 3/128 N 3/121 3/128 3/128 3/127 3/128 3/127 ... 128 3/127 3/127 ... 128 N 3/121 3/128 3/128 3/129 3/129 3/129 3/129 7/16 LV1_20.book Seite 59 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Order No. Export markings Page Order No. Export markings ECCN AL 3UF57 2 EAR99S N 7/17 3VL27 06-2. on req. 3UF59 N N 7/18 3VL27 06-2A EAR99 N 16/11 3UF70 N N 7/8, 16/74 3VL27 06-2B EAR99 N 16/29 3UF71 00 N N 7/8 3VL27 06-2D EAR99 N 16/9, 16/13 3UF71 01 N N 7/8 3VL27 06-2E EAR99 N 16/23, 16/27 3UF71 02 N N 7/8 3VL27 06-3. on req. 3UF71 03-1A N N 7/8 3VL27 06-3A EAR99 N 16/11 3UF71 03-1B N N 7/8, 16/74 3VL27 06-3B EAR99 N 16/29 3UF71 04 N N 7/8, 16/74 3VL27 06-3D EAR99 N 16/9, 16/13 3UF71 10 N N 7/9 3VL27 06-3E EAR99 N 16/23, 16/27 3UF71 11 N N 7/9 3VL27 08 EAR99 N 16/8 ... 9, 16/22 ... 23, 16/26 ... 27 3UF71 12 N N 7/9 3VL27 10-1. on req. 3UF71 13-1A EAR99 N 7/9 3VL27 10-1A EAR99 N 16/10 3UF71 13-1B EAR99 N 7/9 3VL27 10-1B EAR99 N 16/28 3UF71 14 EAR99 N 7/9 3VL27 10-1D EAR99 N 16/8, 16/12 3UF71 5 N N 7/9 3VL27 10-1E EAR99 N 16/22, 16/26, 16/28 3UF72 N N 7/9 3VL27 10-2. on req. 3UF73 N N 7/10 3VL27 10-2A EAR99 N 16/11 3UF74 N N 7/10 3VL27 10-2B EAR99 N 16/29 3UF75 N N 7/10 3VL27 10-2D EAR99 N 16/9, 16/13 3UF77 N N 7/10 3VL27 10-2E EAR99 N 16/23, 16/27, 16/29 3UF79 0 N N 7/11 3VL27 10-3. on req. 3UF79 1 N N 7/11 3VL27 10-3A EAR99 N 16/11 3UF79 2 N N 7/11 ... 12 3VL27 10-3B EAR99 N 16/29 3UF79 3 N N 6/26, 7/11, 16/74 3VL27 10-3D EAR99 N 16/9, 16/13 3UF79 4 N N 1/6, 1/8, 6/26, 7/11, 16/74 3VL27 10-3E EAR99 N 16/23, 16/27, 16/29 3UF79 5 N N 7/11 3VL27 12 EAR99 N 16/8 ... 9, 16/22 ... 23, 16/26 ... 27 3UF79 7 N N 7/12, 16/74 3VL27 16-1. on req. 3UF79 82-0AA00 EAR99 N 7/13 3VL27 16-1A EAR99 N 16/10, 16/19, 16/35 3UF79 82-0AA01 N N 7/13 3VL27 16-1B EAR99 N 16/28 3UF79 82-0AA02 N N 7/13 3VL27 16-1D EAR99 N 16/8, 16/12 3UF79 82-0AA1 EAR99S N 7/13 3VL27 16-1E EAR99 N 16/22, 16/26, 16/28 3UG30 N N 7/56 ... 57 3VL27 16-2. on req. 3UG32 N N 7/56 ... 57, 7/60 3VL27 16-2A EAR99 N 16/11, 16/19, 16/35 3UG4 N N 7/44 ... 45, 7/48, 7/50, 7/52 ... 53, 7/58, 7/61 3VL27 16-2B EAR99 N 16/29 3VL27 16-2D EAR99 N 16/9, 16/13 3VL27 16-2E EAR99 N 16/23, 16/27, 16/29 3VL27 16-3. on req. 3VL27 16-3A EAR99 N 16/11, 16/19, 16/35 3VL27 16-3B EAR99 N 16/29 3VL27 16-3D EAR99 N 16/9, 16/13 3VL27 16-3E EAR99 N 16/23, 16/27, 16/29 3VL37 20-1. on req. 3VL37 20-1A EAR99 N 16/10 3VL37 20-1B EAR99 N 16/28 3VL37 20-1D EAR99 N 16/8 3VL37 20-1E EAR99 N 16/22, 16/26 N N 7/55 3V AL 16/15, 16/17, 16/31, 16/33 16/15, 16/17, 16/31, 16/33 16/14, 16/16, 16/30, 16/32 16/15, 16/17, 16/31, 16/33 16/15, 16/17, 16/31, 16/33 16/14, 16/16, 16/30, 16/32 16/15, 16/17, 16/31, 16/33 16/15, 16/17, 16/31, 16/33 3VF2 EAR99 N 16/75 3VF92 20 N N 16/76 3VF92 21 EAR99 N 16/76 3VF92 22 EAR99 N 16/76 3VF92 23 EAR99 N 16/76 3VF92 24-1L N N 16/76 3VF92 24-1N N N 16/76 3VL17 0 EAR99 N 16/8 ... 9, 16/22 ... 25 3VL17 1 EAR99 N 16/8 ... 9, 16/12 ... 13, 16/22 ... 25, 16/28 ... 29 3VL17 2 EAR99 N 16/8 ... 9, 16/22 ... 25 3VL37 20-2. on req. 3VL17 9 EAR99 N 16/8 ... 9, 16/22 ... 25 3VL37 20-2A EAR99 N 16/11 3VL27 05 EAR99 N 16/8 ... 9, 16/22 ... 23, 16/26 ... 27 3VL37 20-2B EAR99 N 16/29 3VL27 06-1. on req. 16/14, 16/16, 16/30, 16/32 3VL37 20-2D EAR99 N 16/9 3VL27 06-1A EAR99 16/10 3VL37 20-2E EAR99 N 16/23, 16/27 16/28 3VL37 20-3. on req. 16/8, 16/12 3VL37 20-3A EAR99 N 16/11 16/22, 16/26 3VL37 20-3B EAR99 N 16/29 3VL27 06-1B 3VL27 06-1D 3VL27 06-1E EAR99 EAR99 EAR99 N N N N 16/14, 16/16, 16/30, 16/32 16/15, 16/17, 16/31, 16/33 16/15, 16/17, 16/31, 16/33 Siemens LV 1 · 2008 20 3UL ECCN Page 20/59 LV1_20.book Seite 60 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Order No. Export markings Order No. Export markings Page ECCN AL ECCN AL 3VL37 20-3D EAR99 N 16/9 3VL57 50-1E EAR99 N 3VL37 20-3E EAR99 N 16/23, 16/27 3VL57 50-2. on req. 3VL37 25-1. on req. 16/14, 16/16, 16/30, 16/32 3VL57 50-2A EAR99 N 16/11 3VL37 25-1A EAR99 N 16/10, 16/19, 16/35 3VL57 50-2DC EAR99 N 16/9 3VL37 25-1B EAR99 N 16/28 3VL57 50-2DK N N 16/13 3VL37 25-1D EAR99 N 16/8, 16/12 3VL57 50-2E EAR99 N 16/23, 16/27 3VL37 25-1E EAR99 N 16/22, 16/26, 16/28 3VL57 50-3. on req. 3VL37 25-2. on req. 16/15, 16/17, 16/31, 16/33 3VL57 50-3A EAR99 N 16/11 3VL37 25-2A EAR99 N 16/11, 16/19, 16/35 3VL57 50-3DC EAR99 N 16/9 3VL37 25-2B EAR99 N 16/29 3VL57 50-3DK N N 16/13 3VL37 25-2D EAR99 N 16/9, 16/13 3VL57 50-3E EAR99 N 16/23, 16/27 3VL37 25-2E EAR99 N 16/23, 16/27, 16/29 3VL57 63-1. on req. 3VL37 25-3. on req. 16/15, 16/17, 16/31, 16/33 3VL57 63-1A EAR99 N 16/10, 16/19, 16/35 3VL37 25-3A EAR99 N 16/11, 16/19, 16/35 3VL57 63-1B EAR99 N 16/28 3VL37 25-3B EAR99 N 16/29 3VL57 63-1D EAR99 N 16/8, 16/12 3VL37 25-3D EAR99 N 16/9, 16/13 3VL57 63-1E EAR99 N 16/22, 16/26, 16/28 3VL37 25-3E EAR99 N 16/23, 16/27, 16/29 3VL57 63-2. on req. 3VL47 2 EAR99 N 16/8 ... 9, 16/12 ... 13, 16/22 ... 23, 16/26 ... 27 3VL57 63-2A EAR99 N 16/11, 16/19, 16/35 3VL57 63-2B EAR99 N 16/29 3VL57 63-2D EAR99 N 16/9, 16/13 3VL57 63-2E EAR99 N 16/23, 16/27, 16/29 3VL57 63-3. on req. 3VL57 63-3A EAR99 N 16/11, 16/19, 16/35 3VL57 63-3B EAR99 N 16/29 3VL57 63-3D EAR99 N 16/9, 16/13 3VL57 63-3E EAR99 N 16/23, 16/27, 16/29 3VL67 80-1. on req. 3VL67 80-1A EAR99 N 16/10, 16/19, 16/35 3VL67 80-1B EAR99 N 16/28 3VL67 80-1D EAR99 N 16/12 3VL67 80-1E EAR99 N 16/28 3VL67 80-2. on req. 3VL67 80-2A EAR99 N 16/11, 16/19, 16/35 3VL67 80-2B EAR99 N 16/29 3VL67 80-2D EAR99 N 16/13 3VL67 80-2E EAR99 N 16/29 3VL67 80-3. on req. 3VL67 80-3A EAR99 N 16/11, 16/19, 16/35 3VL67 80-3B EAR99 N 16/29 3VL67 80-3D EAR99 N 16/13 3VL67 80-3E EAR99 N 16/29 3VL77 10-1. on req. 3VL77 10-1A EAR99 N 16/10 3VL77 10-1B EAR99 N 16/28 3VL77 10-2. on req. 3VL77 10-2A EAR99 N 16/11 3VL77 10-2B EAR99 N 16/29 3VL77 10-3. on req. 3VL77 10-3A EAR99 N 16/11 N 16/29 16/15, 16/17 16/15, 16/17 16/14, 16/16, 16/30, 16/32 16/15, 16/17, 16/31, 16/33 on req. 3VL47 31-1A EAR99 N 16/10 3VL47 31-1B EAR99 N 16/28 3VL47 31-1D EAR99 N 16/8, 16/12 3VL47 31-1E EAR99 N 16/22, 16/26 3VL47 31-2. on req. 3VL47 31-2A EAR99 N 16/11 3VL47 31-2B EAR99 N 16/29 3VL47 31-2D EAR99 N 16/9, 16/13 3VL47 31-2E EAR99 N 16/23, 16/27 3VL47 31-3. on req. 3VL47 31-3A EAR99 N 16/11 3VL47 31-3B EAR99 N 16/29 3VL47 31-3D EAR99 N 16/9, 16/13 3VL47 31-3E EAR99 N 16/23, 16/27 3VL47 40-1. on req. 3VL47 40-1A EAR99 N 16/10, 16/19, 16/35 3VL47 40-1B EAR99 N 16/28 3VL47 40-1D EAR99 N 16/8, 16/12 3VL47 40-1E EAR99 N 16/22, 16/26, 16/28 3VL47 40-2. on req. 3VL47 40-2A EAR99 N 16/11, 16/19, 16/35 3VL47 40-2B EAR99 N 16/29 3VL47 40-2D EAR99 N 16/9, 16/13 3VL47 40-2E EAR99 N 16/23, 16/27, 16/29 3VL47 40-3. on req. 3VL47 40-3A EAR99 N 16/11, 16/19, 16/35 3VL47 40-3B EAR99 N 16/29 3VL47 40-3D EAR99 N 16/9, 16/13 3VL47 40-3E EAR99 N 16/23, 16/27, 16/29 3VL57 3 EAR99 N 16/8 ... 9, 16/12 ... 13, 16/22 ... 23, 16/26 ... 27 3VL77 10-3B EAR99 3VL57 4 EAR99 N 16/8 ... 9, 16/22 ... 23, 16/26 ... 27 3VL77 12-1. on req. 3VL57 50-1. on req. 16/14, 16/16 3VL77 12-1A EAR99 N 16/10, 16/19, 16/35 16/10 3VL77 12-1B EAR99 N 16/28 16/8 3VL77 12-1D EAR99 N 16/12 16/12 3VL77 12-1E EAR99 N 16/28 EAR99 3VL57 50-1DC 3VL57 50-1DK 20/60 EAR99 N 16/14, 16/16, 16/30, 16/32 16/22, 16/26 3VL47 31-1. 3VL57 50-1A 20 Page 16/15, 16/17, 16/31, 16/33 16/15, 16/17, 16/31, 16/33 16/14, 16/16, 16/30, 16/32 16/15, 16/17, 16/31, 16/33 16/15, 16/17, 16/31, 16/33 N N N Siemens LV 1 · 2008 16/15, 16/17, 16/31, 16/33 16/14, 16/16, 16/30, 16/32 16/15, 16/17, 16/31, 16/33 16/15, 16/17, 16/31, 16/33 16/14, 16/16, 16/30, 16/32 16/15, 16/17, 16/31, 16/33 16/15, 16/17, 16/31, 16/33 16/14, 16/16, 16/30, 16/32 LV1_20.book Seite 61 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Order No. Export markings ECCN Page Order No. ECCN AL 16/15, 16/17, 16/31, 16/33 3VL93 00-3M EAR99 AL Export markings Page 3VL77 12-2. on req. N 16/46 3VL77 12-2A EAR99 N 16/11, 16/19, 16/35 3VL93 00-3T EAR99 N 16/57 3VL77 12-2B EAR99 N 16/29 3VL93 00-4 EAR99 N 16/49 ... 51, 16/57 3VL77 12-2D EAR99 N 16/13 3VL93 00-8 EAR99 N 16/56 ... 57, 16/62 ... 63, 16/70 ... 71 3VL77 12-2E EAR99 N 16/29 3VL93 20-6 on req. 3VL77 12-3. on req. 16/15, 16/17, 16/31, 16/33 3VL93 20-7 N N 16/20 3VL77 12-3A EAR99 N 16/11, 16/19, 16/35 3VL93 20-8 EAR99 N 16/69 3VL77 12-3B EAR99 N 16/29 3VL93 21 EAR99 N 16/62 ... 63 3VL77 12-3D EAR99 N 16/13 3VL93 25-5 N N 16/55 3VL77 12-3E EAR99 N 16/29 3VL93 25-6 on req. 3VL87 16-1. on req. 16/14, 16/16, 16/30, 16/32 3VL93 25-7 N N 16/20 3VL87 16-1A EAR99 N 16/10, 16/19, 16/35 3VL93 25-8 EAR99 N 16/69 3VL87 16-1B EAR99 N 16/28 3VL94 00-1SC N N 16/40 3VL87 16-1D EAR99 N 16/12 3VL94 00-1SJ EAR99 N 16/40 3VL87 16-1E EAR99 N 16/28 3VL94 00-1SK N N 16/40 3VL87 16-2. on req. 16/15, 16/17, 16/31, 16/33 3VL94 00-1SM EAR99 N 16/40 3VL87 16-2A EAR99 N 16/11, 16/19, 16/35 3VL94 00-1SQ N N 16/40 3VL87 16-2B EAR99 N 16/29 3VL94 00-1SR N N 16/40 3VL87 16-2D EAR99 N 16/13 3VL94 00-1ST N N 16/40 3VL87 16-2E EAR99 N 16/29 3VL94 00-1SV EAR99 N 16/40 3VL87 16-3. on req. 16/15, 16/17, 16/31, 16/33 3VL94 00-1UD EAR99 N 16/40 3VL87 16-3A EAR99 N 16/11, 16/19, 16/35 3VL94 00-1UG EAR99 N 16/40 3VL87 16-3B EAR99 N 16/29 3VL94 00-1UH EAR99 N 16/40 3VL87 16-3D EAR99 N 16/13 3VL94 00-1UJ EAR99 N 16/40 3VL87 16-3E EAR99 N 16/29 3VL94 00-1UK EAR99 N 16/40 3VL90 00-3 on req. 16/43 3VL94 00-1UL EAR99 N 16/40 3VL90 00-4 EAR99 N 16/49 ... 54 3VL94 00-1UM EAR99 N 16/40 3VL90 00-8 EAR99 N 16/62 ... 67, 16/74 3VL94 00-1UN N N 16/40 3VL91 0 EAR99 N 16/49, 16/56 3VL94 00-1UP N N 16/40 3VL91 12-5GA N N 16/55 3VL94 00-1UQ EAR99 N 16/40 3VL91 12-5GB EAR99 N 16/55 3VL94 00-1UR EAR99 N 16/40 3VL92 00-3 EAR99 N 16/56 ... 57 3VL94 00-1US EAR99 N 16/40 3VL92 00-4 EAR99 N 16/50, 16/56 ... 57 3VL94 00-1UT EAR99 N 16/40 3VL92 05 N N 16/20 3VL94 00-1UU N N 16/40 3VL92 06-6 on req. 16/21, 16/36 ... 37 3VL94 00-1UV EAR99 N 16/40 3VL92 06-7 N N 16/20 3VL94 00-2AB EAR99 N 16/40 3VL92 08 N N 16/20 3VL94 00-2AD EAR99 N 16/40 3VL92 10-6 on req. 16/21, 16/36 ... 37 3VL94 00-2AH EAR99 N 16/42 3VL92 10-7 N N 16/20 3VL94 00-2AJ EAR99 N 16/42 3VL92 10-8 EAR99 N 16/69 3VL94 00-3A EAR99 N 16/44 3VL92 12 N N 16/20 3VL94 00-3HA EAR99 N 16/44 3VL92 16-5 N N 16/55 3VL94 00-3HC EAR99 N 16/44 3VL92 16-6 on req. 16/21, 16/36 ... 37 3VL94 00-3HE EAR99 N 16/44 3VL92 16-7 N N 16/20 3VL94 00-3HF EAR99 N 16/44 3VL92 16-8 EAR99 N 16/69 3VL94 00-3HG EAR99 N 16/44 3VL92 8 EAR99 N 16/69 3VL94 00-3HL EAR99 N 16/64 3VL93 00-3A EAR99 N 16/43 3VL94 00-3HN EAR99 N 16/47 3VL93 00-3HA EAR99 N 16/43 3VL94 00-3HP EAR99 N 16/44 3VL93 00-3HC EAR99 N 16/43 3VL94 00-3HR on req. 3VL93 00-3HE EAR99 N 16/43 3VL94 00-3MJ N N 16/47 3VL93 00-3HF EAR99 N 16/43 3VL94 00-3ML EAR99 N 16/47 3VL93 00-3HG EAR99 N 16/43 3VL94 00-3MN EAR99 N 16/47 3VL93 00-3HL EAR99 N 16/62 ... 63 3VL94 00-3MQ EAR99 N 16/47 3VL93 00-3HP EAR99 N 16/43 3VL94 00-3MS EAR99 N 16/47 3VL93 00-3HR N N 16/43 3VL94 00-3T EAR99 N 16/58 ... 60 16/21, 16/36 ... 37 16/21, 16/36 ... 37 Siemens LV 1 · 2008 20 16/44 20/61 LV1_20.book Seite 62 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Order No. Export markings Order No. Export markings Page ECCN AL ECCN AL 3VL94 00-4 EAR99 N 16/51, 16/58 3VL98 00-1UP N N 16/41 3VL94 00-8 EAR99 N 16/58, 16/64, 16/70 3VL98 00-1UQ EAR99 N 16/41 3VL94 20-7DC EAR99 N 16/20 3VL98 00-1UR N N 16/41 3VL94 20-7DK N N 16/20 3VL98 00-1US N N 16/41 3VL94 25 N N 16/20 3VL98 00-1UT EAR99 N 16/41 3VL94 31-6 on req. 16/21, 16/36 ... 37 3VL98 00-1UU N N 16/41 3VL94 31-7 N N 16/20 3VL98 00-1UV N N 16/41 3VL94 40-5 EAR99 N 16/55 3VL98 00-2 EAR99 N 16/41 3VL94 40-6 on req. 16/21, 16/36 ... 37 3VL98 00-3A EAR99 N 16/48 3VL94 40-7 N N 16/20 3VL98 00-3H EAR99 N 16/48, 16/66 ... 67 3VL94 40-8 EAR99 N 16/69 3VL98 00-3MJ EAR99 N 16/48 3VL95 00-3 on req. 16/45 3VL98 00-3ML EAR99 N 16/48 3VL95 00-4 EAR99 N 16/52, 16/59 3VL98 00-3MN EAR99 N 16/48 3VL95 00-8 EAR99 N 16/64 ... 65 3VL98 00-3MQ N N 16/48 3VL95 3 EAR99 N 16/20 3VL98 00-3MS EAR99 N 16/48 3VL95 4 EAR99 N 16/20 3VL98 00-4 EAR99 N 16/53 ... 54, 16/60 ... 61 3VL95 50-6 on req. 16/21 3VL98 00-8 EAR99 N 16/60 ... 61, 16/66 ... 67, 16/72 ... 73 3VL95 50-7 EAR99 16/20 3VL98 16-2 EAR99 N 16/42 3VL95 63-6 on req. 16/21, 16/36 ... 37 3VL98 16-6 on req. 3VL95 63-7 EAR99 N 16/20 3VL98 16-8 EAR99 3VL95 63-8 EAR99 N 16/69 3W 3VL96 00-3A EAR99 N 16/45 3WL11 on req. 3VL96 00-3H EAR99 N 16/45, 16/47, 16/65 15/6 ... 7, 15/10 ... 11, 15/14 ... 15, 15/18 ... 19 3VL96 00-3M EAR99 N 16/47 3WL12 on req. 15/6 ... 8, 15/10 ... 12, 15/14 ... 16, 15/18 ... 20, 15/47 ... 48 3VL96 00-4 EAR99 N 16/52 ... 53, 16/59 3WL13 on req. 3VL96 00-8B EAR99 N 16/65, 16/71 15/8 ... 9, 15/12 ... 13, 15/16 ... 17, 15/20 ... 21 3VL96 00-8CA EAR99 N 16/59 3WL91 11-0AA1 N N 15/31 16/59 3WL91 11-0AA2 N N 15/31 16/59 3WL91 11-0AA3 N N 15/31 16/58 ... 59 3WL91 11-0AA5 N N 15/31 N N 15/31 3VL96 00-8CB3 3VL96 00-8CB4 3VL96 00-8CE N EAR99 EAR99 N N N N 16/21, 16/37 N 16/69 3VL96 00-8L EAR99 N 16/65 3WL91 11-0AA6 3VL96 00-8S EAR99 N 16/65 3WL91 11-0AB01 N N 15/36 3VL96 80-6 on req. 16/21, 16/36 ... 37 3WL91 11-0AB02 N N 15/36 3VL96 80-8 EAR99 N 16/69 3WL91 11-0AB03 N N 15/36 3VL97 0 EAR99 N 16/60, 16/63 ... 67 3WL91 11-0AB04 N N 15/36 3VL97 10 on req. 16/21, 16/37 3WL91 11-0AB07 N N 15/36 16/21, 16/37 3WL91 11-0AB08 N N 15/36 16/69 3WL91 11-0AB10 N N 15/36 16/62 ... 67 3WL91 11-0AB12 N N 15/36 16/41 3WL91 11-0AB18 N N 15/36 N N 15/37 3VL97 12-6 on req. 3VL97 12-8 EAR99 3VL97 15 EAR99 3VL98 00-1SC N N N N 3VL98 00-1SJ EAR99 N 16/41 3WL91 11-0AD 3VL98 00-1SK N N 16/41 3WL91 11-0AE N N 15/37 3VL98 00-1SM EAR99 N 16/41 3WL91 11-0AF N N 15/37 3VL98 00-1SQ N N 16/41 3WL91 11-0AG N N 15/37 3VL98 00-1SR N N 16/41 3WL91 11-0AH N N 15/35 3VL98 00-1ST N N 16/41 3WL91 11-0AJ N N 15/35 16/41 3WL91 11-0AK N N 15/31 ... 32 16/41 3WL91 11-0AL N N 15/42 16/41 3WL91 11-0AM0 N N 15/42 16/41 3WL91 11-0AM9 on req. N N 15/43 3VL98 00-1SV 3VL98 00-1UD 3VL98 00-1UG 3VL98 00-1UH 20 Page N N N N N N N N 15/44 3VL98 00-1UJ N N 16/41 3WL91 11-0AN0 3VL98 00-1UK EAR99 N 16/41 3WL91 11-0AN1 N N 15/43 3VL98 00-1UL N N 16/41 3WL91 11-0AN20 N N 15/43 3VL98 00-1UM EAR99 N 16/41 3WL91 11-0AN21 N N 15/43 3VL98 00-1UN N N 16/41 3WL91 11-0AN22 N N 15/43 20/62 Siemens LV 1 · 2008 LV1_20.book Seite 63 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Export markings Page Order No. Export markings Page ECCN AL ECCN AL 3WL91 11-0AN23 N N 15/43 4AU N N 10/58 ... 59, 10/86 ... 87 3WL91 11-0AN24 N N 15/43 4AV N N 11/5 ... 10 3WL91 11-0AN25 N N 15/43 4AX N N 10/52 ... 53 3WL91 11-0AN26 N N 15/43 4B 3WL91 11-0AN27 N N 15/43 4BU43 32-2A N N 10/64, 10/67, 10/70, 10/72 3WL91 11-0AN28 N N 15/43 4BU43 32-2C N N 10/65, 10/68, 10/70, 10/72 3WL91 11-0AN3 N N 15/43 4BU43 32-2E N N 10/66, 10/69, 10/71, 10/73 3WL91 11-0AN4 N N 15/43 4BU43 32-5A N N 10/64, 10/67, 10/70, 10/72 3WL91 11-0AP N N 15/38 4BU43 32-5C N N 10/65, 10/68, 10/70, 10/72 3WL91 11-0AR N N 15/38 4BU43 32-5E N N 10/66, 10/69, 10/71, 10/73 3WL91 11-0AS N N 15/38 4BU43 33-2A N N 10/74, 10/77, 10/80, 10/82 3WL91 11-0AT N N 15/31 ... 32, 15/34, 15/40 ... 41, 16/74 4BU43 33-2C N N 10/75, 10/78, 10/80, 10/82 4BU43 33-2E N N 10/76, 10/79, 10/81, 10/83 4BU43 33-5A N N 10/74, 10/77, 10/80, 10/82 4BU43 33-5C N N 10/75, 10/78, 10/80, 10/82 4BU43 33-5E N N 10/76, 10/79, 10/81, 10/83 4BU43 42-2A N N 10/64, 10/67, 10/70, 10/72 4BU43 42-2C N N 10/65, 10/68, 10/70, 10/72 4BU43 42-2E N N 10/66, 10/69, 10/71, 10/73 4BU43 42-5A N N 10/64, 10/67, 10/70, 10/72 4BU43 42-5C N N 10/65, 10/68, 10/70, 10/72 4BU43 42-5E N N 10/66, 10/69, 10/71, 10/73 4BU43 43-2A N N 10/74, 10/77, 10/80, 10/82 4BU43 43-2C N N 10/75, 10/78, 10/80, 10/82 4BU43 43-2E N N 10/76, 10/79, 10/81, 10/83 4BU43 43-5A N N 10/74, 10/77, 10/80, 10/82 4BU43 43-5C N N 10/75, 10/78, 10/80, 10/82 4BU43 43-5E N N 10/76, 10/79, 10/81, 10/83 4BU43 52-2A N N 10/64, 10/67, 10/70, 10/72 4BU43 52-2C N N 10/65, 10/68, 10/70, 10/72 4BU43 52-2E N N 10/66, 10/69, 10/71, 10/73 4BU43 52-5A N N 10/64, 10/67, 10/70, 10/72 4BU43 52-5C N N 10/65, 10/68, 10/70, 10/72 4BU43 52-5E N N 10/66, 10/69, 10/71, 10/73 4BU43 53-2A N N 10/74, 10/77, 10/80, 10/82 4BU43 53-2C N N 10/75, 10/78, 10/80, 10/82 4BU43 53-2E N N 10/76, 10/79, 10/81, 10/83 4BU43 53-5A N N 10/74, 10/77, 10/80, 10/82 4BU43 53-5C N N 10/75, 10/78, 10/80, 10/82 4BU43 53-5E N N 10/76, 10/79, 10/81, 10/83 4BU45 32-2A N N 10/64, 10/67, 10/70, 10/72 4BU45 32-2C N N 10/65, 10/68, 10/70, 10/72 4BU45 32-2E N N 10/66, 10/69, 10/71, 10/73 4BU45 32-5A N N 10/64, 10/67, 10/70, 10/72 4BU45 32-5C N N 10/65, 10/68, 10/70, 10/72 4BU45 32-5E N N 10/66, 10/69, 10/71, 10/73 4BU45 33-2A N N 10/74, 10/77, 10/80, 10/82 4BU45 33-2C N N 10/75, 10/78, 10/80, 10/82 4BU45 33-2E N N 10/76, 10/79, 10/81, 10/83 4BU45 33-5A N N 10/74, 10/77, 10/80, 10/82 4BU45 33-5C N N 10/75, 10/78, 10/80, 10/82 4BU45 33-5E N N 10/76, 10/79, 10/81, 10/83 4BU45 42-2A N N 10/64, 10/67, 10/70, 10/72 4BU45 42-2C N N 10/65, 10/68, 10/70, 10/72 4BU45 42-2E N N 10/66, 10/69, 10/71, 10/73 3WL91 11-0BA0 N N 15/39 3WL91 11-0BA10 N N 15/39 3WL91 11-0BA13 N N 15/34 3WL91 11-0BA14 N N 15/34, 16/40 ... 41 3WL91 11-0BA2 N N 15/32 3WL91 11-0BA3 N N 15/32 3WL91 11-0BA4 N N 15/32 3WL91 11-0BA5 N N 15/32 3WL91 11-0BA7 N N 15/32, 15/35 3WL91 11-0BA8 N N 15/32 ... 33 3WL91 11-0BB1 N N 15/33 3WL91 11-0BB2 N N 15/33 3WL91 11-0BB3 N N 15/33 3WL91 11-0BB4 N N 15/33 3WL91 11-0BB5 N N 15/39 3WL91 11-0BB6 N N 15/40 3WL91 11-0BB7 N N 15/40 3WL91 11-0BC N N 15/40, 15/44, 16/74 3WL91 11-0BD N N 15/45 3WL91 12 N N 15/33 3WL92 on req. 3WL93 N 15/29 ... 30, 15/49 N 15/31 3Z 3ZS1 5D992B1 N 1/3 ... 4, 1/6, 1/8, 6/26, 7/13, 16/74 3ZS23 N N 15/40, 16/74, 18/7 3ZS27 EAR99 N 18/5 ... 6 3ZX on req. 6/17, 6/27 4A 4AM2 4AM3 4AM4 4AM5 4AM6 4AP 4AT30 1 4AT30 3 4AT36 0 4AT36 1 4AT36 3 4AT39 0 4AT39 1 4AT39 3 4AT4 N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N 10/20 ... 23, 10/42 ... 46 10/6 ... 19, 10/24 ... 41 10/6 ... 19, 10/24 ... 41 10/6 ... 19, 10/24 ... 41 10/24 ... 41 10/58 ... 60, 10/86 ... 87 10/54 10/24 ... 36, 10/39 ... 41 10/54 10/24 ... 36, 10/39 ... 41, 10/54 10/24 ... 36, 10/39 ... 41 10/54 10/24 ... 36, 10/39 ... 41, 10/54 10/24 ... 36, 10/39 ... 41 10/54 Siemens LV 1 · 2008 20 Order No. 20/63 LV1_20.book Seite 64 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings 20 Order No. Export markings Page Order No. Export markings Page ECCN AL ECCN AL 4BU45 42-5A N N 10/64, 10/67, 10/70, 10/72 4BU52 33-5C N N 10/75, 10/78, 10/80, 10/82 4BU45 42-5C N N 10/65, 10/68, 10/70, 10/72 4BU52 33-5E N N 10/76, 10/79, 10/81, 10/83 4BU45 42-5E N N 10/66, 10/69, 10/71, 10/73 4BU53 32-2A N N 10/64, 10/67, 10/70, 10/72 4BU45 43-2A N N 10/74, 10/77, 10/80, 10/82 4BU53 32-2C N N 10/65, 10/68, 10/70, 10/72 4BU45 43-2C N N 10/75, 10/78, 10/80, 10/82 4BU53 32-2E N N 10/66, 10/69, 10/71, 10/73 4BU45 43-2E N N 10/76, 10/79, 10/81, 10/83 4BU53 32-5A N N 10/64, 10/67, 10/70, 10/72 4BU45 43-5A N N 10/74, 10/77, 10/80, 10/82 4BU53 32-5C N N 10/65, 10/68, 10/70, 10/72 4BU45 43-5C N N 10/75, 10/78, 10/80, 10/82 4BU53 32-5E N N 10/66, 10/69, 10/71, 10/73 4BU45 43-5E N N 10/76, 10/79, 10/81, 10/83 4BU53 33-2A N N 10/74, 10/77, 10/80, 10/82 4BU47 32-2A N N 10/64, 10/67, 10/70, 10/72 4BU53 33-2C N N 10/75, 10/78, 10/80, 10/82 4BU47 32-2C N N 10/65, 10/68, 10/70, 10/72 4BU53 33-2E N N 10/76, 10/79, 10/81, 10/83 4BU47 32-2E N N 10/66, 10/69, 10/71, 10/73 4BU53 33-5A N N 10/74, 10/77, 10/80, 10/82 4BU47 32-5A N N 10/64, 10/67, 10/70, 10/72 4BU53 33-5C N N 10/75, 10/78, 10/80, 10/82 4BU47 32-5C N N 10/65, 10/68, 10/70, 10/72 4BU53 33-5E N N 10/76, 10/79, 10/81, 10/83 4BU47 32-5E N N 10/66, 10/69, 10/71, 10/73 4BU53 42-2A N N 10/64, 10/67, 10/70, 10/72 4BU47 33-2A N N 10/74, 10/77, 10/80, 10/82 4BU53 42-2C N N 10/65, 10/68, 10/70, 10/72 4BU47 33-2C N N 10/75, 10/78, 10/80, 10/82 4BU53 42-2E N N 10/66, 10/69, 10/71, 10/73 4BU47 33-2E N N 10/76, 10/79, 10/81, 10/83 4BU53 42-5A N N 10/64, 10/67, 10/70, 10/72 4BU47 33-5A N N 10/74, 10/77, 10/80, 10/82 4BU53 42-5C N N 10/65, 10/68, 10/70, 10/72 4BU47 33-5C N N 10/75, 10/78, 10/80, 10/82 4BU53 42-5E N N 10/66, 10/69, 10/71, 10/73 4BU47 33-5E N N 10/76, 10/79, 10/81, 10/83 4BU53 43-2A N N 10/74, 10/77, 10/80, 10/82 4BU47 42-2A N N 10/64, 10/67, 10/70, 10/72 4BU53 43-2C N N 10/75, 10/78, 10/80, 10/82 4BU47 42-2C N N 10/65, 10/68, 10/70, 10/72 4BU53 43-2E N N 10/76, 10/79, 10/81, 10/83 4BU47 42-2E N N 10/66, 10/69, 10/71, 10/73 4BU53 43-5A N N 10/74, 10/77, 10/80, 10/82 4BU47 42-5A N N 10/64, 10/67, 10/70, 10/72 4BU53 43-5C N N 10/75, 10/78, 10/80, 10/82 4BU47 42-5C N N 10/65, 10/68, 10/70, 10/72 4BU53 43-5E N N 10/76, 10/79, 10/81, 10/83 4BU47 42-5E N N 10/66, 10/69, 10/71, 10/73 4BU54 32-2A N N 10/64, 10/67, 10/70, 10/72 4BU47 43-2A N N 10/74, 10/77, 10/80, 10/82 4BU54 32-2C N N 10/65, 10/68, 10/70, 10/72 4BU47 43-2C N N 10/75, 10/78, 10/80, 10/82 4BU54 32-2E N N 10/66, 10/69, 10/71, 10/73 4BU47 43-2E N N 10/76, 10/79, 10/81, 10/83 4BU54 32-5A N N 10/64, 10/67, 10/70, 10/72 4BU47 43-5A N N 10/74, 10/77, 10/80, 10/82 4BU54 32-5C N N 10/65, 10/68, 10/70, 10/72 4BU47 43-5C N N 10/75, 10/78, 10/80, 10/82 4BU54 32-5E N N 10/66, 10/69, 10/71, 10/73 4BU47 43-5E N N 10/76, 10/79, 10/81, 10/83 4BU54 33-2A N N 10/74, 10/77, 10/80, 10/82 4BU47 52-2A N N 10/64, 10/67, 10/70, 10/72 4BU54 33-2C N N 10/75, 10/78, 10/80, 10/82 4BU47 52-2C N N 10/65, 10/68, 10/70, 10/72 4BU54 33-2E N N 10/76, 10/79, 10/81, 10/83 4BU47 52-2E N N 10/66, 10/69, 10/71, 10/73 4BU54 33-5A N N 10/74, 10/77, 10/80, 10/82 4BU47 52-5A N N 10/64, 10/67, 10/70, 10/72 4BU54 33-5C N N 10/75, 10/78, 10/80, 10/82 4BU47 52-5C N N 10/65, 10/68, 10/70, 10/72 4BU54 33-5E N N 10/76, 10/79, 10/81, 10/83 4BU47 52-5E N N 10/66, 10/69, 10/71, 10/73 4BU54 42-2A N N 10/64, 10/67, 10/70, 10/72 4BU47 53-2A N N 10/74, 10/77, 10/80, 10/82 4BU54 42-2C N N 10/65, 10/68, 10/70, 10/72 4BU47 53-2C N N 10/75, 10/78, 10/80, 10/82 4BU54 42-2E N N 10/66, 10/69, 10/71, 10/73 4BU47 53-2E N N 10/76, 10/79, 10/81, 10/83 4BU54 42-5A N N 10/64, 10/67, 10/70, 10/72 4BU47 53-5A N N 10/74, 10/77, 10/80, 10/82 4BU54 42-5C N N 10/65, 10/68, 10/70, 10/72 4BU47 53-5C N N 10/75, 10/78, 10/80, 10/82 4BU54 42-5E N N 10/66, 10/69, 10/71, 10/73 4BU47 53-5E N N 10/76, 10/79, 10/81, 10/83 4BU54 43-2A N N 10/74, 10/77, 10/80, 10/82 4BU52 32-2A N N 10/64, 10/67, 10/70, 10/72 4BU54 43-2C N N 10/75, 10/78, 10/80, 10/82 4BU52 32-2C N N 10/65, 10/68, 10/70, 10/72 4BU54 43-2E N N 10/76, 10/79, 10/81, 10/83 4BU52 32-2E N N 10/66, 10/69, 10/71, 10/73 4BU54 43-5A N N 10/74, 10/77, 10/80, 10/82 4BU52 32-5A N N 10/64, 10/67, 10/70, 10/72 4BU54 43-5C N N 10/75, 10/78, 10/80, 10/82 4BU52 32-5C N N 10/65, 10/68, 10/70, 10/72 4BU54 43-5E N N 10/76, 10/79, 10/81, 10/83 4BU52 32-5E N N 10/66, 10/69, 10/71, 10/73 4BU55 32 N N 10/64 ... 69 4BU52 33-2A N N 10/74, 10/77, 10/80, 10/82 4BU55 33 N N 10/74 ... 79 4BU52 33-2C N N 10/75, 10/78, 10/80, 10/82 4BU56 32 N N 10/64 ... 69 4BU52 33-2E N N 10/76, 10/79, 10/81, 10/83 4BU56 33 N N 10/74 ... 79 4BU52 33-5A N N 10/74, 10/77, 10/80, 10/82 4BU56 42 N N 10/64 ... 69 20/64 Siemens LV 1 · 2008 LV1_20.book Seite 65 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Order No. Export markings Page Order No. Export markings Page AL ECCN AL N N 10/74 ... 79 5SH33 N N 19/69 ... 70 4BU58 32 N N 10/64 ... 69 5SH34 N N 19/70 4BU58 33 N N 10/74 ... 79 5SH35 0 N N 14/44, 19/79, 19/125 4BU58 42 N N 10/64 ... 69 5SH35 2 N N 14/45 ... 46, 19/134 4BU58 43 N N 10/74 ... 79 5SH35 30 N N 14/45, 19/134 4BU58 52 N N 10/64 ... 69 5SH35 31 N N 14/46, 19/134 4BU58 53 N N 10/74 ... 79 5SH35 32 N N 14/45, 19/134 4BU59 32 N N 10/64 ... 69 5SH35 33 N N 14/44, 19/134 4BU59 33 N N 10/74 ... 79 5SH35 34 N N 14/44, 19/134 4BU60 32 N N 10/64 ... 69 5SH35 35 N N 14/48, 19/125 4BU60 33 N N 10/74 ... 79 5SH35 36 N N 14/45, 14/47, 19/127, 19/134 5SH35 37 N N 14/45, 14/47, 19/127, 19/134 4F 4FK N N 10/56 5SH35 4 N N 19/79 4FL N N 10/55, 10/88 5SH35 5 N N 19/79 5SH35 6 N N 19/79 5SH37 N N 19/69 5SH4 N N 19/62 5SH50 N N 19/63 5SH51 N N 19/63 5SH52 N N 14/55, 19/61 ... 62, 19/130 5SH53 N N 19/77 ... 78 5SH54 N N 19/63 5SH55 0 N N 19/63 5SH55 1 N N 19/77 5SH55 25 N N 19/131 5SH55 26 N N 19/131 5SH55 27 N N 19/59, 19/131 5SJ N N 19/20, 19/33 ... 35 5SK N N 19/37 ... 38 5SM1 N N 19/46 5SM2 N N 19/24 ... 25, 19/49 ... 50 5SM31 N N 19/40 5SM33 1 N N 19/40 ... 42 5SM33 42-4 EAR99H N 19/43 5SM33 42-6 N N 19/40 ... 42 5SM33 44-4 EAR99H N 19/43 5SM33 44-6 N N 19/40 ... 42 5SM33 45 N N 19/40 5SM33 46-4 EAR99H N 19/43 5SM33 46-6 N N 19/40 ... 42 5SM33 47-4 EAR99H N 19/43 5SM33 47-6 N N 19/40 ... 41 5SM33 5 N N 19/41 5SM34 N N 19/40, 19/42 5SM36 1 N N 19/40, 19/42 5SM36 42-4 EAR99H N 19/43 5SM36 42-6 N N 19/40 5SM36 44-4 EAR99H N 19/43 5SM36 44-6 N N 19/40 ... 42 5SM36 44-8 N N 19/42 5SM36 45 N N 19/40, 19/42 5SM36 46-4 EAR99H N 19/43 5SM36 46-5 EAR99H N 19/43 5SM36 46-6 N N 19/40 ... 42 5SM36 46-8 N N 19/41 ... 42 4N 4NC N N 14/69 ... 70 5S 5SA N N 19/66 5SB N N 19/66 5SC N N 19/66 5SD4 N N 19/121 5SD5 N N 19/121 5SD6 N N 19/67 5SD74 1 N N 19/135, 19/140 5SD74 2 N N 19/138, 19/140 5SD74 3 N N 19/139 ... 141 5SD74 42 N N 19/136 5SD74 43 N N 19/136 5SD74 44 N N 19/136 5SD74 48 N N 19/140 5SD74 6 N N 19/137 ... 138, 19/140 5SD74 8 N N 19/137, 19/140 5SD74 9 N N 19/140 5SD8 N N 19/66 5SE N N 19/59, 19/123 5SF N N 14/55, 19/67 ... 68, 19/130 5SG1 N N 19/60 ... 61 5SG5 N N 19/60 ... 61 5SG6 N N 14/55, 19/129 5SG71 1 N N 19/59 5SG71 2 N N 19/59 5SG71 3 N N 19/59 5SG71 5 N N 19/59 5SG71 6 N N 19/59 5SG72 N N 19/131 5SG76 N N 19/60 5SG77 N N 19/60 5SH1 N N 19/68 5SH2 N N 14/55, 19/69, 19/130 5SH30 N N 19/69, 19/130 5SH31 N N 19/69 5SH32 0 N N 19/69 5SH32 1 N N 19/69 5SH32 2 N N 19/69 5SH32 8 N N 19/69 Siemens LV 1 · 2008 20 ECCN 4BU56 43 20/65 LV1_20.book Seite 66 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings 20 Order No. Export markings Page Order No. ECCN AL 5SM36 47-4 EAR99H N 19/43 5T 5SM36 47-5 EAR99H N 19/43 5SM36 47-6 N N 19/40, 19/42 5SM36 5 N N 5SM37 42 N 5SM37 44 Export markings Page ECCN AL 5TE68 0 N N 5TE68 1 on req. 19/41 5TE9 N N 19/143 N 19/40 5TG N N 19/26 N N 19/40 5TT N N 19/90 5SM37 45 N N 19/40, 19/42 6A 5SM37 46-4 EAR99H N 19/43 6AG N N 7/22 6B EAR99H N 7/27 6ED10 50 N N 7/22, 7/24, 7/26 ... 27 6ED10 52 N N 7/21, 7/23 6ED10 55 N N 7/25 6ED10 56 N N 7/22, 7/24, 7/26 6ED10 57-1 N N 1/3, 6/79, 7/22, 7/24, 7/26 6ED10 57-3 EAR99T N 7/22, 7/26 6ED10 57-4 N N 7/29 6ED10 58 N N 7/22, 7/24, 7/26, 7/30 6EP13 N N 11/11 ... 13 6EP14 N N 11/13 6EP17 N N 11/12 6EP19 31 N N 11/15 6EP19 35-6MC EAR99H N 11/16 6EP19 35-6MD1 N N 11/16 6EP19 35-6MD3 EAR99H N 11/16 6EP19 35-6ME N N 11/16 6EP19 35-6MF N N 11/16 6EP19 6 N N 11/14 6ES5 N N 6/97 ... 99 6ES71 31-4BB EAR99H N 6/100 6ES71 31-4BD01-0AA EAR99H N 6/100 6ES71 31-4BD01-0AB N N 6/100 6ES71 31-4BD5 EAR99H N 6/100 6ES71 31-4C EAR99H N 6/100 6ES71 31-4E EAR99H N 6/100 6ES71 31-4F EAR99H N 6/100 6ES71 31-4R EAR99H N 6/100 6ES71 32-4BB0 EAR99H N 6/100 6ES71 32-4BB31-0AA N N 6/100 6ES71 32-4BB31-0AB EAR99H N 6/100 6ES71 32-4BD0 N N 6/100 6ES71 32-4BD3 on req. 6ES71 32-4F on req. 6ES71 32-4HB0 N N 6/100 6ES71 32-4HB1 EAR99H N 6/100 6ES71 34-4F N N 6/100 6ES71 34-4G EAR99H N 6/100 6ES71 34-4J EAR99H N 6/100 6ES71 34-4L EAR99H N 6/100 6ES71 34-4M EAR99H N 6/100 6ES71 34-4N EAR99H N 6/100 6ES71 35 EAR99H N 6/100 6ES71 38-4A EAR99H N 6/99 6ES71 38-4CA EAR99H N 6/99 6ES71 38-4CB on req. 5SM37 46-5 EAR99H N 19/43 5SM37 46-6 N N 19/40 5SM37 47-4 EAR99H N 19/43 5SM37 47-5 EAR99H N 19/43 5SM38 N N 19/42 5SP N N 19/12, 19/36 5ST13 N N 19/36 ... 37 5ST18 N N 19/38 5ST21 34 N N 19/27, 19/57 5ST21 35 N N 19/27, 19/57 5ST21 36 N N 19/27, 19/57 5ST21 4 N N 19/56 5ST21 56 N N 19/56 5ST21 57 N N 19/56, 19/78 5ST21 7 N N 19/26, 19/57 5ST21 8 N N 19/77 5ST21 9 N N 19/77 5ST22 N N 19/26, 19/57 5ST30 N N 19/23, 19/46 5ST36 N N 19/30 ... 31, 19/56, 19/78 5ST37 0 N N 19/31 ... 32, 19/56, 19/77 ... 78 5ST37 1 N N 19/31 ... 32, 19/77 ... 78 5ST37 3 N N 19/31, 19/56 5ST37 40 N N 19/31 5ST37 41 N N 19/31 5ST37 42 N N 19/31 5ST37 43 N N 19/31 5ST37 44 N N 19/31 5ST37 45 N N 19/31 5ST37 46 N N 19/31 5ST37 48 N N 19/32, 19/78 5ST37 5 N N 19/32, 19/56, 19/78 5ST37 6 N N 19/32 5ST38 N N 19/26, 19/47, 19/54 5SU N N 19/43 ... 44, 19/52 ... 53 5SW N N 19/27, 19/46 ... 47, 19/57 5SY4 N N 19/8 ... 11 5SY5 N N 19/13 5SY60 on req. 5SY61 N N 19/5 ... 6 5SY62 N N 19/5 ... 6 5SY63 N N 19/5, 19/7 5SY64 N N 19/5, 19/7 5SY65 N N 19/5 ... 6 5SY66 N N 19/5, 19/7 5SY7 N N 19/14 ... 16 5SY8 N N 19/17 ... 18 20/66 19/21 Siemens LV 1 · 2008 6BK 19/142 ... 143 19/143 6E 6/100 6/100 6/99 LV1_20.book Seite 67 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Order No. Export markings Page Order No. Export markings Page ECCN AL ECCN AL 6ES71 38-4CF EAR99H N 6/101 6ES71 94-4BD EAR99H N 6ES71 38-4DA EAR99H N 6/103 6ES71 94-4BH on req. 6ES71 38-4DB N N 6/102 6ES71 94-4C EAR99H N 6/126 ... 127 6ES71 38-4DC N N 6/103 6ES71 94-4D EAR99H N 6/118, 6/127 6ES71 38-4DD N N 6/103 6ES71 94-4E EAR99H N 6/126 6ES71 38-4DE EAR99H N 6/103 6ES71 94-4F EAR99H N 6/126 6ES71 38-4DF EAR99H N 6/104 6ES71 94-4G N N 6/121, 6/123, 6/125 6ES71 38-4DL N N 6/103 6ES71 94-4H N N 6/123, 6/125 ... 128 6ES71 38-4FA on req. 6/101 6ES71 95 N N 6/96 6ES71 38-4FB EAR99H N 6/101 6ES73 N N 2/20 ... 21, 6/102 6ES71 38-4FD EAR99H N 6/99 6ES77 N N 6/98 ... 99 6ES71 38-4G EAR99H N 6/102 6ES78 N N 6/101 6ES71 38-4H N N 6/98 6ES79 0 N N 6/81 6ES71 41 EAR99H N 6/126 6ES79 5 N N 6/97 ... 99 6ES71 42 EAR99H N 6/126 6ES79 72-0BA EAR99H N 2/30 6ES71 44 EAR99H N 6/127 6ES79 72-0BB N N 16/74 6ES71 45 EAR99H N 6/127 6ES79 91 N N 6/124 6ES71 48-4CA0 EAR99H N 6/127 6ES79 98 5D992B1 N 6/96 ... 97, 6/101, 6/124 ... 125 6ES71 48-4CA6 on req. 6/128 6F 6ES71 48-4E EAR99H 6/128 6FX2 on req. 6/103 N N 6/102 ... 103 6/128 6ES71 48-4F EAR99H N 6/118, 6/127 6FX5 6ES71 51-1AA N N 6/96 6G 6ES71 51-1AB EAR99H N 6/96 6GK14 11 EAR99H N 2/28 6ES71 51-1B on req. 6/96, 6/101 6GK14 15-2A N N 2/32 6ES71 51-1CA00-0 N 6/96 6GK14 15-2B EAR99H N 2/30 6/96 6GK19 00 EAR99H N 2/28, 2/30 6/96 6GK19 01-0DB N N 6/126 6/97 6GK19 01-0DM EAR99H N 6/126 6/98 6GK19 01-0F EAR99H N 6/96 6/98 6GK19 01-1 N N 2/28, 2/30, 6/97, 6/125 N N 6/122 ... 124, 6/128 6ES71 51-1CA00-1 6ES71 51-1CA00-3 6ES71 51-3 6ES71 51-7AA 6ES71 51-7AB EAR99H EAR99H EAR99H N N N N on req. N N 6ES71 51-7F N N 6/99 6GK19 05 6ES71 54-1 EAR99H N 6/122 6GK19 7 N N 2/18, 2/20 ... 21, 2/32 6ES71 54-2 EAR99H N 6/122, 6/127 6GK5 5A991 N 6/125 6ES71 54-4AB0 EAR99H N 6/127 6GK71 N N 2/18 6ES71 54-4AB1 on req. 6/124 6GK72 43-2AX00 N N 2/19 6/125 6GK72 43-2AX01 EAR99H N 2/19 6/96 ... 100, 6/102 ... 103 6GK73 N N 2/20 ... 21 6S 6SL32 0 N N 6/80 6SL32 3 on req. 6SL32 5 N 6SL32 6 on req. 6ES71 54-8 6ES71 93-4B EAR99H N N N 6ES71 93-4C N N 6/101 ... 102, 6/104 ... 108 6ES71 93-4D N N 6/96 6ES71 93-4F 6ES71 93-4G N N N N 6/96 6/100, 6/102 ... 103, 6/105 ... 106, 6/108 6ES71 93-4J N N 6/97 ... 99 6X 6ES71 93-4L N N 6/82, 6/102, 6/108 6XV 6ES71 94-1 N N 2/43, 2/65, 6/64, 6/122 7K 6ES71 94-3 N N 6/123 6ES71 94-4AA 6ES71 94-4AC 6ES71 94-4AD EAR99H EAR99H EAR99H N N N 6/128 N 6/81 6/128 N N 6/97, 6/122 ... 125, 6/128 7KT10 0 N N 19/158 6/122 7KT10 10 N N 19/158 6/122 7KT10 11 N N 19/158 6/122 7KT10 12 N N 19/158 N N 19/158 6ES71 94-4AF on req. 6/124 7KT10 2 6ES71 94-4AG on req. 6/124 7KT11 1 N N 19/157 6ES71 94-4AJ on req. 6/124 7KT11 2 N N 19/157 6ES71 94-4AN EAR99H N 6/125 7KT11 4 N N 19/157 6ES71 94-4BA EAR99H N 6/127 7KT11 6 N N 19/155 6/127 7KT12 N N 19/155 7KT13 N N 19/145, 19/147, 19/150 6ES71 94-4BC EAR99H N Siemens LV 1 · 2008 20 N 6/127 20/67 LV1_20.book Seite 68 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Order No. Export markings Page Order No. Page ECCN AL ECCN AL 7KT15 N N 19/153 8US19 21-2AC N N 14/37, 14/49, 19/126 7KT55 N N 19/160 8US19 21-2AD00 N N 14/37, 14/49, 19/126 7KT56 N N 19/160 8US19 21-2AD01 N N 14/37, 14/49 7KT58 0 N N 19/159 8US19 21-2BA N N 14/37, 14/49, 19/126 7KT58 1 N N 19/159 8US19 21-2BB N N 14/37, 14/49, 19/126 7KT58 2 N N 19/159 8US19 21-2BC N N 14/37, 14/49, 19/126 7KT58 3 N N 19/159 8US19 21-2BD00 N N 14/37, 14/49, 19/126 7KT90 0 N N 19/160 8US19 21-2BD01 N N 14/37, 14/49 7KT90 10 N N 19/156 8US19 21-2BE N N 14/46, 14/56 7KT90 11 N N 19/156 8US19 21-2BF N N 14/42, 14/46, 14/56 7KT90 2 N N 19/160 8US19 22-1 N N 14/37, 14/44, 14/46, 14/49, 19/134 7KT90 3 N N 19/155 8US19 22-2 N N 14/36, 14/45, 14/47, 19/125 8US19 23 N N 14/44, 19/134 7M 7MH44 EAR99H N 6/105 8US19 27 N N 14/51, 16/69 7MH46 EAR99H N 6/104 8US19 41-2AA01 N N 14/49 7MH47 N N 6/105 ... 106 8US19 41-2AA02 N N 14/49 7MH49 N N 6/104, 6/106 8US19 41-2AA03 N N 14/48 8US19 41-2AA04 N N 14/49 8G 8GK4 N N 19/124, 19/127 8US19 41-2AC N N 14/49 8GK97 1 N N 19/125 8US19 41-2B N N 14/47, 14/49, 19/126 8GK97 3 N N 19/125 8US19 43 N N 14/47 8US19 48 N N 14/47 8US19 98-1 N N 6/53, 14/38 ... 39, 14/42, 14/50 ... 52, 14/56, 19/132 8H 8HP27 0 N N 17/10 8HP27 1 N N 17/10 8HP27 3 N N 17/10 8US19 98-2 N N 6/53, 14/39, 14/52, 19/132 8HP27 4 N N 17/10 8US19 98-4 N N 14/42, 14/56 8HP27 5 N N 17/10 8US19 98-7 N N 5/29, 6/52, 14/42, 14/56 8HP27 6 N N 17/10 8US19 98-8 N N 6/53, 14/42, 14/56 8HP6 N N 17/57, 19/107 8W 8WA28 03 N N 8JH N N 19/79, 19/126 3/113, 5/29, 5/57, 7/79, 7/84, 7/86, 7/88 8JK N N 19/126 8WA28 07 -- 8WA28 4 N N 6/100, 6/102, 6/105 ... 106, 6/108 8J 8U 2/50 8UB N N 17/8 ... 9 8WA28 6 N N 6/100, 6/102, 6/105 ... 106, 6/108 8UC60 N N 14/66, 17/11 ... 13, 17/36 ... 38, 17/42 ... 43 8WA28 8 N N 3/113, 4/10, 4/19, 5/29, 5/57, 7/79, 7/84, 7/86, 7/88 8UC61 N N 16/76 8WA8 N N 6/102, 6/108 14/66 8WC50 2 on req. 14/59, 14/61, 14/63, 14/65 ... 66, 17/5, 17/11, 17/34, 17/36, 17/41 ... 42 8WC50 5 N N 14/46 8WC50 6 N N 14/46 8WC51 N N 14/46 8WD N N 9/105 ... 110 8WH N N 5/51 N N 6/105 8UC70 N 8UC71 N 8UC72 N 8UC73 N N N N N 14/59, 14/61, 14/63, 14/65 ... 66, 17/5, 17/11, 17/34, 17/36, 17/41 ... 42 14/59, 14/61, 14/63, 14/65 ... 66, 17/5, 17/7, 17/9, 17/11 ... 13, 17/34, 17/37, 17/41, 17/43 14/36 C7 C71 E2 8UC74 N N 14/59, 14/61, 14/63, 14/65 ... 66, 17/12 ... 13, 17/34, 17/38 8UC9 N N 14/66 ... 67, 17/7 ... 9, 17/12 ... 13, 17/34, 17/38 LZS:M N N 3/92 8US10 N N 5/23, 5/29, 6/52, 14/38 ... 39, 16/68 LZS:P T1 N N 3/92 8US11 N N 5/23, 14/39, 14/51 LZS:P T3 EAR99 N 3/90 8US12 N N 5/23, 5/29, 6/52, 14/48, 14/50 ... 52, 16/69, 17/68, 19/111, 19/132 LZS:P T5 EAR99 N 3/90 LZS:P T7 N N 3/91 LZS:P TM N N 3/92, 3/94 LZS:R T1 N N 3/94 LZS:R T3A4L N N 3/93 LZS:R T3A4R EAR99 N 3/93 8US19 0 N 8US19 21-1 N 8US19 21-2AA 20 Export markings 8US19 21-2AB 20/68 N N N N N N Siemens LV 1 · 2008 14/36 14/48, 19/125 14/37, 14/49, 19/126 14/37, 14/49, 19/126 E20 on req. 15/40 LZ LV1_20.book Seite 69 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Order No. Index Including export markings Order No. Export markings Page ECCN AL LZS:R T3A4S EAR99 N 3/93 LZS:R T3A4T EAR99 N 3/93 LZS:R T3B4L N N 3/93 LZS:R T3B4R EAR99 N 3/93 LZS:R T3B4S EAR99 N 3/93 LZS:R T3B4T EAR99 N 3/93 LZS:R T3D4L N N 3/93 LZS:R T3D4R EAR99 N 3/93 LZS:R T3D4S EAR99 N 3/93 LZS:R T3D4T EAR99 N 3/93 LZS:R T4A4L N N 3/93 LZS:R T4A4R EAR99 N 3/93 LZS:R T4A4S EAR99 N 3/93 LZS:R T4A4T N N 3/93 LZS:R T4B4L N N 3/93 LZS:R T4B4R EAR99 N 3/93 LZS:R T4B4S EAR99 N 3/93 LZS:R T4B4T N N 3/93 LZS:R T4D4L N N 3/93 LZS:R T4D4R EAR99 N 3/93 LZS:R T4D4S EAR99 N 3/93 LZS:R T4D4T N N 3/93 LZS:R T7 N N 3/94 LZX:M T321 EAR99 N 3/92 LZX:M T323 EAR99 N 3/92 LZX:M T326 EAR99 N 3/92 LZX:M T3280 EAR99 N 3/92 LZX:M T3281 N N 3/92 LZX:M T3282 EAR99 N 3/92 LZX:P T2 N N 3/91 LZX:P T3 EAR99 N 3/91 LZX:P T52 N N 3/91 LZX:P T57 EAR99 N 3/91 LZX:P T58 EAR99 N 3/91 LZX:R T3140 N N 3/94 LZX:R T3145 EAR99 N 3/94 LZX:R T3146 EAR99 N 3/94 LZX:R T3147 EAR99 N 3/94 LZX:R T3150 EAR99 N 3/94 LZX:R T3157 N N 3/94 LZX:R T4240 N N 3/94 LZX:R T4245 EAR99 N 3/94 LZX:R T4246 EAR99 N 3/94 LZX:R T4247 N N 3/94 Z2 on req. 2/61 20 Z23 Siemens LV 1 · 2008 20/69 LV1_20.book Seite 70 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix Conditions of sale and delivery Export regulations ■ Terms and Conditions of Sale and Delivery By using this catalog you can acquire hardware and software products described therein from Siemens AG subject to the following terms. Please note! The scope, the quality and the conditions for supplies and services, including software products, by any Siemens entity having a registered office outside of Germany, shall be subject exclusively to the General Terms and Conditions of the respective Siemens entity. The following terms apply exclusively for orders placed with Siemens AG. For customers with a seat or registered office in Germany The “General Terms of Payment” as well as the “General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry” shall apply. For software products, the “General License Conditions for Software Products for Automation and Drives for Customers with a Seat or registered Office in Germany” shall apply. For customers with a seat or registered office outside of Germany The “General Terms of Payment” as well as the “General Conditions for Supplies of Siemens, Automation and Drives for Customers with a Seat or registered Office outside of Germany” shall apply. For software products, the “General License Conditions for Software Products for Automation and Drives for Customers with a Seat or registered Office outside of Germany” shall apply. 20 General The dimensions are in mm. In Germany, according to the German law on units in measuring technology, data in inches only apply to devices for export. Illustrations are not binding. Insofar as there are no remarks on the corresponding pages, - especially with regard to data, dimensions and weights given these are subject to change without prior notice. The prices are in € (Euro) ex works, exclusive packaging. The sales tax (value added tax) is not included in the prices. It shall be debited separately at the respective rate according to the applicable legal regulations. Prices are subject to change without prior notice. We will debit the prices valid at the time of delivery. Surcharges will be added to the prices of products that contain silver, copper, aluminum, lead and/or gold if the respective basic official prices for these metals are exceeded. These surcharges will be determined based on the official price and the metal factor of the respective product. The surcharge will be calculated on the basis of the official price on the day prior to receipt of the order or prior to the release order. The metal factor determines the official price as of which the metal surcharges are charged and the calculation method used. The metal factor, provided it is relevant, is included with the price information of the respective products. 20/70 Siemens LV 1 · 2008 An exact explanation of the metal factor and the text of the Comprehensive Terms and Conditions of Sale and Delivery are available free of charge from your local Siemens business office under the following Order Nos.: • 6ZB5310-0KR30-0BA1 (for customers based in Germany) • 6ZB5310-0KS53-0BA1 (for customers based outside Germany) or download them from the Internet http://www.siemens.com/automation/mall (Germany: A&D Mall Online-Help System) ■ Export regulations The products listed in this catalog / price list may be subject to European / German and/or US export regulations. Therefore, any export requiring a license is subject to approval by the competent authorities. According to current provisions, the following export regulations must be observed with respect to the products featured in this catalog / price list: AL Number of the German Export List Products marked other than “N” require an export license. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an “AL“ not equal to “N” are subject to a European or German export authorization when being exported out of the EU. ECCN Export Control Classification Number Products marked other than “N” are subject to a reexport license to specific countries. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an “ECCN“ not equal to “N” are subject to a US re-export authorization. Even without a label or with an “AL: N” or “ECCN: N”, authorization may be required due to the final destination and purpose for which the goods are to be used. The deciding factors are the AL or ECCN export authorization indicated on order confirmations, delivery notes and invoices. Errors excepted and subject to change without prior notice. A&D/VuL_ohne MZ/En 05.09.06 LV1_20.book Seite 71 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix 20 Notes Siemens LV 1 · 2008 20/71 LV1_20.book Seite 72 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix 20 Notes 20/72 Siemens LV 1 · 2008 LV1_20.book Seite 73 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix 20 Notes Siemens LV 1 · 2008 20/73 LV1_20.book Seite 74 Montag, 28. Januar 2008 12:32 12 © Siemens AG 2008 Appendix 20 Notes 20/74 Siemens LV 1 · 2008