GE Molded Case Circuit Breakers J600 Line Circuit Breakers 125-600 Amperes 600 Volts ac 250 Volts dc Type TJ J Noninterchangeable Trip (Includes Line and Load Lugs) Suitable for reverse feed. Adjustable Trip 125 150 175 200 225 250 300 350 400 Lugs Type TJK 400NA 2-Pole. 400 Amp Frame 600 Vac, 250 Vdc Amp Ampere Rating Lo Hi 375 1250 1500 1750 450 525 600 675 750 900 1050 1200 2000 2250 2500 3000 3500 4000 - - Catalog Number TJJ426125WL TJJ426150WL TJJ426175WL TJJ426200WL TJJ426225WL TJJ4262SOWL TJJ426300WL TJJ426350WL TJJ426400WL - TJJ426Y400O® 3-Pole, 400 Amp Frame 600 Volts ac List Price, GO-135B $2118.00 2118.00 2118.00 2118.00 2118.00 2118.00 2118.00 2118.00 2118.00 Catalog Number TJJ436125WL TJJ436150WL TJJ436175WL TJJ436200WL TJJ436225WL TJJ436250WL TJJ436300WL TJJ436350WL TJJ436400WL 1577.00 Copper/ Lugs List Price, GO-135B $2573.00 2573.00 2573.00 2573.00 2573.00 2573.00 2573.00 2573.00 2573.00 TJJ436Y400S)® Included in price (1)6-600 kcmil (2)2/0-250 kcmil 1904.00 Types TJK, THJK Interchangeable Trip Adjustable Trip Range Amp Complete Circuit Breaker Includes line and load lugs Ampere Rating Standard Lo Hi Catalog Number Frame Only Hi-Break" List Price, GO-135B Catalog Number List Price, GO-135B $2116.00 2118.00 2118.00 2118.00 2118.00 2118.00 2118.00 2118.00 2118.00 THJK426125WL THJK426150WL THJK426175WL THJK426200WL THJK426225WL THJK426250WL THJK426300WL THJK426350WL THJK426400WL $3085.00 3085.00 3085.00 3085.00 3085.00 3085.00 3085.00 3085.00 3085.00 List Price, GO-13SB Catalog Number Term nal Lugs for Front Connection (Cof per/Aluminum) ® Trip Unit Only ' Use with Standard and Hi-Break Frames List Price, GO-135B Catalog Number (Order 2 per Pole) List Price, GO-135B Wire Size 400 Amp Frame Two-Pole 125 150 175 200 225 250 300 350 400 . 400NA 375 450 525 600 675 750 900 1050 1200 2000 2250 2500 3000 3500 4000 TJK426125WL TJK426150WL TJK426175WL TJK426200WL • TJK426225WL TJK426250WL TJK426300WL TJK426350WL TJK426400WL - - TJK426Y4000® 1874.00 TJK436125WL TJK436150WL TJK436175WL TJK436200WL TJK436225WL TJK436250WL TJK436300WL TJK436350WL TJK436400WL 2573.00 2573.00 2573.00 2573.00 2573.00 2573.00 2573.00 2573.00 2573.00 1250 1500 1750 - TJK426FOOO Standard Frame $ 1598.00 THJK426FOOO Hi-Break 2565.00 TJK426T125 TJK426T150 TJK426T175 TJK426T200 TJK426T225 TJK426T250 TJK426T300 TJK426T350 TJK426T400 $464.00 464.00 464.00 464.00 464.00 464.00 464.00 464.00 464.00 TJKY3® 212.00 TJK436T125 TJK436T150 TJK436T175 TJK436T200 TJK436T225 TJK436T250 TJK436T300 TJK436T350 TJK436T400 464.00 464.00 464.00 464.00 464.00 464.00 464.00 464.00 464.00 - TJK436TM1400® TJK436TM2400® TJK436TM3400® 558.00 558.00 558.00 - TJKY3® 212.00 - 0) 6-600 kcmil or Twin 2/0-250 TCAL43® $ 14.00 TCAL43® 14.00 (1) 6-600 kcmil or Twin 2/0-250 kcmil TCAL43® 14.00 (1) 6-600 kcmil or Twin 2/0-250 kcmil Three-Pole 125 150 175 200 225 250 300 350 400 375 450 525 600 675 750 900 1050 1200 2000 2250 2500 3000 3500 4000 400A 600 1200 350 2000 4000 1000 - - Mag Only 400NA 1250 1500 1750 — TJK436Y400® @ — 2330.00 THJK436125WL THJK436150WL THJK436175WL THJK436200WL THJK436225WL THJK436250WL THJK436300WL THJK436350WL THJK436400WL 3675.00 3675.00 3675.00 3675.00 3675.00 3675.00 3675.00 3675.00 3675.00' — - TJK436FOOO Standard Frame 2025.00 THJK436FOOO Hi-Break Frame 3127.00 600 Amp Frame Two-Pote 250 300 350 400 750 900 1050 1200 2500 3000 3500 4000 TJK626250WL TJK626300WL TJK626350WL TJK626400WL 2812.00 2812.00 2812.00 2812.00 THJK626250WL THJK626300WL THJK626350WL THJK626400WL 3704.00 3704.00 3704.00 3704.00 TJK626FOOO Standard Frame 1535.00 450 500 600 1350 1500 1800 4500 5000 6000 TJK626450WL TJK626500WL TJK626600WL 2848.00 2848.00 2848.00 THJK626450WL THJK626500WL THJK626600WL 3740.00 3740.00 3740.00 THJK626FOOO Hi-Break Frame 2427.00 - - TJK626Y600O® 1844.00 600NA - TJK626T250 TJK626T300 TJK626T350 TJK626T400 1221.00 1221.00 1221.00 1221.00 TJK626T450 TJK626T500 TJK626T600 1221.00 1221.00 1221.00 212.00 TJKY36® - Twin 4/0-350 kcmil-Cu or Twin ' 300-500 kcmil-AI Three-Pole TJK636T250 TJK636T300 TJK636T350 TJK636T400 1221.00 1221.00 1221.00 1221.00 TJK636T45D TJK636T500 TJK636T600 1221.00 1221.00 1221.00 = TJK636TM1600® TJK636TM2600® 1465.00 1465.00 - TJKY36® 250 300 350 400 750 900 1050 1200 2500 3000 3500 4000 TJK636250WL TJK636300WL TJK636350WL TJK636400WL 3539.00 3539.00 3539.00 3539.00 THJK636250WL THJK636300WL THJK636350WL THJK636400WL 4457.00 4457.00 4457.00 4457.00 450 500 600 1350 1500 1800 4500 5000 6000 TJK636450WL TJK636500WL TJK636600WL 3593.00 3593.00 3593.00 THJK636450WL THJK636500WL THJK636600WL 4511.00 4511.00 4511.00 600 1800 2000 6000 . - - - - 2595.00 - 600A Mag Only 600NA I - TJK636Y600CD® © Molded-case switch includes line and load lugs. TJK636FOOO Standard .Frame 2234.00 THJK636FOOO Hi-Break Frame 3152.00 Internal accessory installation requires dummy trip unit. See page 4-51 for additional details. Nonautomatic trip unit and dummy trip unit not UL listed for field installation. Alternate lug for 750 kcmil Cu/AI cable, Catalog Number TCAL47 List Price $26.00, GO-135B. 0 Not UL listed. For optional lugs, see page TCAL43O 14.00 0) 6-600 kcmil or Twin 2/0-250 kcmil TCAL63 23.00 Twin 4/0-350 kcmii-Cu or Twin 300-500 kcmil-AI 212.00 Accessories: See pages 4-48 to 4-65. 4-62. Prices and data subject to change without notice 1999 Issue 4-23 GF Molded Case Circuit Breakers Molded Case Circuit Breakers , Spectra RMS™, Spectra RMS™ with MicroVersaTrip Plus™ Trip Units, Spectra RMS™ with MicroVersaTrip PM™ Trip Units, Thermal Magnetic and J/K with MicroVersaTrip® HMS-9 and Power+™ 4 Trip Units How to Order QLine • Thermal Magnetic Circuit Breakers • Molded-Case Switches The catalog number as shown in the following pages includes the complete breaker or switch. TQD and TJD breakers are complete with Cu/AI line and load lugs. Spectra RMS™ • Circuit Breakers Determine the required breaker frame, 1C rating, and load requirements. Select frame, trip unit (rating plug), and lug, if required, catalog numbers from the tables on pages 4-18 and 4-19. Select field-mounted internal accessory catalog numbers, if required, on page 4-47. Select field-mounted external accessory catalog numbers, if required, on pages 4-48 through 4-65. Order as separate items. For Spectra breakers with MicroVersaTrip Plus Trip Units or MicroVersaTrip PM Trip Units refer to page 4-26 through 4-35. • Mag-Break Motor Circuit Protectors Determine the required frame and ampere requirements. Select frame, trip unit (rating plug), and lug, if required, catalog numbers from the table on page 4-42. Select accessories as noted above for circuit breakers. The same accessories are used with both circuit breakers and motor circuit protectors. Order as separate items. • Molded-Case Switches Determine the required frame and ampere requirements. Select frame and lug, if required, catalog numbers from the table on page 4-20. Rating plugs are not used. Select accessories as noted above for circuit breakers. Internal accessories do not require dummy trips. The same accessories are used with both circuit breakers and molded-case switches. Order as separate items. Unless otherwise noted, all circuit breakers are UL listed in File E-11592. Molded-case switches are UL listed in File E-57546. Field-Installable Internal Accessories are UL listed in File E-57253. Distribution Cable Accessories for MicroVersaTrip Plus Trip Units and MicroVersaTrip PM Trip Units are UL listed in File E-57253. E150 Line Thermal Magnetic Circuit Breakers Magnetic Circuit Breakers Molded-Case Switches The catalog numbers as shown in the following pages include the complete breaker or switch. All devices listed come with Cu/AI line and load lugs. If line lugs are not required on a breaker, eliminate "WL" from catalog number; for molded-case switches see page 4-3. Unless otherwise noted, all circuit breakers are UL listed in File E-11592. Molded-case switches are UL listed in File E-57546. Molded-case switches can also be ordered as complete units (designated TFK—Y) or as separate components. They are UL listed only as complete units. To indicate required lugs, see page 4-3. Unless otherwise noted, all circuit breakers are UL listed in File E-11592. Molded-case switches are UL listed in File E-57546. J 600 Line • Thermal Magnetic Circuit Breakers • Magnetic Circuit Breakers • Molded-Case Switches These breakers are available with either noninterchangeable trip (designated Type TJJ) or interchangeable trip (designated Type TJK and THJK). Type TJJ catalog numbers include frame, trip, Cu/AI line, and load lugs factory assembled. If line lugs are not required on the breaker, eliminate "WL" from catalog number, and subtract price of line lugs from price of complete breaker. TJK breakers are available in two frames, 400 ampere frame (125 to 400 amperes) and 600 ampere frame (250 to 600 • . amperes). Trip units are not interchangeable between frames. "Complete Circuit Breaker" price includes frame, trip unit, Cu/AI line, and load lugs. Unit will be shipped unassembled unless order specifies "must be factory assembled." If line lugs are not required, eliminate "WL" from catalog number and subtract price of line lugs from price of complete breaker. To order the frame, trip, and lugs separately, select the required components from table. Magnetic breakers must be ordered as components. A complete breaker consists of frame, trip, and one line and one load lug per pole. Price of ordering "Complete Circuit Breaker" vs. frame, trip, and line and load lugs separately is the same. Molded-case switches can also be ordered as complete units (designated Type TJK—Y) or as separate components. They are UL listed only as complete units. To indicate required lugs, see page 4-3. F 225 Line • Thermal Magnetic Circuit Breakers • Magnetic Circuit Breakers • Molded-Case Switches These breakers are available with either noninterchangeable trips (designated Type TFJ) or interchangeable trips (designated Types TFK/THFK). When ordering Type TFJ, catalog number includes 4-2 complete breaker, trip unit, Cu/AI line and load lugs factory assembled. If line lugs are not required on a breaker, eliminate "WL" from catalog number, and subtract price of line lugs from price of complete breaker. If interchangeable trip (Types TFK/ THFK) is required order one of two ways. "Complete circuit breaker" price includes frame, trip, Cu/AI line and load lugs. Units will be shipped unassembled unless specified on order "must be factory assembled." If line lugs are not required on a breaker, eliminate "WL" from catalog number, and subtract price of line lugs from price of complete breaker. To order the frame, trip, and lugs separately, select the required components from table. Magnetic breakers must be ordered as components. A complete breaker consists of frame, trip unit, one line lug per pole and one load lug per pole. Price of "Complete Circuit Breaker" vs. ordering frame, trip, and line and load lugs separately is the same. Unless otherwise noted, all circuit breakers are UL listed in File E-11592. Molded-case switches are UL listed in File E-57546. 1999 Issue (continued on next page) Data subject to change without notice GE Molded Case Circuit Breakers Molded Case Circuit Breakers K1200 Line • Thermal Magnetic Circuit Breakers • Magnetic Breakers • Molded-Case Switches These breakers are available only with interchangeable trip units. Two frame sizes are available, the 800 ampere frame (300 to 800 amperes) and the 1200 ampere frame (600 to 1200 amperes). Trip units are not interchangeable between frames. "Complete Circuit Breaker" price includes frame, trip, Cu/AI line, and load lugs. Units will be shipped unassembled unless specified "must be factory assembled." If line lugs are not required on the breaker, eliminate "WL" from catalog number and subtract price of line lugs. To order the frame, trip, and lugs separately, select the required components from table. Magnetic circuit breakers must be ordered as components. A complete breaker consists of frame, trip and one line and one load lug per pole. Price of ordering "Complete Circuit Breaker" vs. frame, trip, and line and load lugs separately is the same. Molded-case switches can also be ordered as complete units (designated Type TKMA—Y) or as separate components. They are UL listed only as complete units. To indicate required lugs, see the table below. These breakers are available in four types. Type TB1 (15-100 amperes) catalog numbers include frame, trip, line and load lugs, and current limiters all factory assembled. Types TB4 (125 to 400 amperes), TB6 (300 to 600 amperes) and TB8 (600 to 800 amperes) include frame, trip and limiters, factory assembled, but do not include line or load lugs. If line and load lugs are required, order separately. Unless otherwise noted, TB1, TB4, TB6, and TB8 breaker components are UL listed in File E-42263. Fused molded-case switches are UL listed in File E-57546. Mag-Break9 Line • Magnetic only circuit breakers (motor circuit protectors) These breakers are available only with noninterchangeable adjustable magnetic trip, in frame Types E, F, J, K, and Tri-Break. All breakers are shipped factory assembled, complete with Cu/AI line and load lugs. All magnetic only circuit breakers and limiters are UL Component Recognized in Files E-11592 and E-66390, respectively, unless otherwise noted. Accessories Order accessories from the appropriate table: Thermal Magnetic Circuit Breakers, Magnetic Circuit Breakers, and Molded-Case Switches®—pages 4-48 to 4-65. MicroVersaTrip RMS-9 or 4-function Solid-State Circuit Breakers— . pages 4-48 to 4-65. x Unless otherwise noted, all circuit breakers are UL listed in File E-11592. Molded-case switches are UL listed in File E-57546. © Installation of accessories in molded-case switches requires dummy trip; see page 4-51 for information. Dummy trip not required for Tri-Break or Q Line molded-case switches. R Frame—1000/1600/2000 Amp Molded-Case Circuit Breakers • Solid-state MicroVersaTrip Plus™ or MicroVersaTrip PM™ Trip Unit • Interchangeable trip unit via rating plugs • 65 and 100 kA ratings available • Standard and 100% rated versions • Uses standard Power Break* accessories • Stationary/manual only Spectra RMS™ Breakers—pages 4-47 to 4-65. Spectra RMS™ Breakers with MicroVersaTrip Plus™ Trip Units or MicroVersaTrip PM™ Trip Units—pages 4-32 to 4-35 and 4-47 to 4-65. Current Limiting Circuit Breakers • 150, 225, 400 and 600 ampere frame sizes • UL listed interrupting ratings are 200 kA at 240 and 480 volts ac maximum and 50 kA at 600 volts ac maximum • Thermal magnetic construction Molded-Case Circuit Breaker and Switch Terminal Configuration Code Order standard Cu/AI lugs by using suffix codes presented. Order lugs separately if special lugs are required. For optional lugs, see page 4-62. Suffix Breaker/Switch Type Circuit Breakers with MicroVersaTrip' Trip Units • Solid-state construction with MicroVersaTrip RMS-9 digital rms sensing microprocessor trip units. • Available in J and K frame construction with ampere ratings from 60-1200A. For ordering information see pages 4-36 through 4-41. UL listed, File E-11592. All breakers are UL listed in File E-11592. TQD/TJD Molded Case Breakers, Thermal Magnetic Molded Case Switch Spectra RMS™ Breakers J.K. MicroVersaTrip" Breakers Mine Duty™ Breakers Mag- Break* Breakers Tri-Break' Line • Integrally Fused Thermal Magnetic Circuit Breakers • Integrally Fused Magnetic Circuit Breakers • Integrally Fused Molded-Case Switches Blank Load Lugs Only Load Lugs Only Line and Load Lugs No Lugs WL XL X2 LL - Line Lugs Only No Lugs Line and Load Lugs - Line Lugs Only No Lugs - No Lugs Line Lugs Only Load Lugs Only Line and Load Lugs Order Lugs Separately No Lugs No Lugs Line and Load Lugs Order Lugs Separately Order Lugs Separately - - - — For E 150 circuit breakers suffix XL is used to specify "no lugs". Data subject to change without notice 1999 Issue 4-3 pi N II GE Molded Case Circuit Breakers Molded Case Circuit Breakers t. VERTICAL Quick Reference Guide Ratings do not apply to molded-case switches. TJJ, TJK, THJK TFJ, TFK, THFK E150 (UL File E-11592; Fixed Thermal Magnetic Trip Unit; CSA LR 57114) Circuit Breaker Type Ampere Rating Poles 1 TEY® 15-100 UL Listed Interrupting Ratings— rms Symmetrical Amps (In Thousands) ac Voltage do Voltage Maximum Voltage Rating No. ac do 120 277 125 65 2 250 120/240 1 10-100 9> 10-100 TED® THED® TEL® 125 250 3 — 1 277,347® 125 480 250 14 65 14 10 — - 500 15-30 1 277,347® 125 — 15-100 2 480 250 65 10 18 18 65 480,600 — 65 - — 500® — — 10 10 — — — — - 100 100 5 — — — — 10 — 65 W A B c E 3'/18 - - - - 3% 24'/64 2'%4 D 5'/4 2 3 26 lb/24 1% 65/ie 2%' %2 4Vfr "/16 1% __ 23/4 3% Z"A> 20® 25 - 10 10 41* — — 1% 20® — 28 lb/8 26 lb/24 23 21%4 /32 24lb/12 '/16 28 lb/8 26 lb/24 —— 24lb/12 65/16 41/a 10 24 lb/1 2 s 1 — Approx. Ship Wt./ Std. Pack 1 6^16 10 18 - H — — — 25 - 42 - 250 10 14 15-100 600 14 - 600 3 - 10 3 -15-150 - 125 5 - 10-150 3 600 — — 2 ' 480 - 15-100 110-150 Jlte^ 120 2 277 14 - 3 TEB® 240 Dimensions (In.) 3% 2"/tn 1s 2 /64 "/,6 2 %2 28 lb/8 - - 5 6 /ie 4'/B ytte 27/16 2'%2 11 /16 3Vz lb/1 2 %2 "225 (UL File E-11592; TFJ, Fixed Thermal Magnetic Trip Unit; TFK, THFK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350) Circuit Breaker Type TFJ® Ampere Rating 70-225 70-250 TFK® 70-225 THFK® 70-225 TFL® 70-225 No. Poles 2 UL Listed Interrupting Ratings — rms Symmetrical Amps (In Thousands) ac Voltage dc Voltage Maximum Voltage Rating ac dc 480 250 3 600 500 2 480 250 3 600 — 2 480 250 3 600 — 3 600 - 120 120/240 240 277 480 22 25 125 600 — 22 65 - 100 100 25 - 65 250 500® 10 — H 10'/8 18 25 Dimensions (in.) 10® 10 _ 10 — 18 — — — 20® _ 18 — — - - - 25 W 41* D 3'Vie Approx. Ship Wt./ Std. Pack A B C E 3% 3'/B "/16 1 3 /16 10 lb/1 • 12 lb/1 101* 4% 31yi« 10 lb/1 3% 3% "/,e 1*i6 7 "/16 1Vie 11 1*ie 12 lb/1 10 lb/1 10'/B 41* 3^18 3 /6 3% 101* '41* 3«/16 3% 3% /16 12 lb/1 - J600 (UL File E-11592; TJJ, Fixed Thermal Magnetic Trip Unit; TJK, THJK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350) TJK4 250-600 THJK4 250-600 2 250 3 500 2 600 500 2 250 3 — 2 600 3 20 250 3 10 22 42 30 65 250 35 — 17'/2lb/1 10 — 20® 20 40 — — — 40 — - _ 81/4 3 15 /16 18 lb/1 3^16 20 lb/1 1% 16 lb/1 1*6 17Vzlb/1 18 lb/1 3'3/16 - 16lb/1 3% ' 20® 3«/16 20 lb/1 K1200 (UL File E-11592; Interchangeable Thermal Magnetic Trip Unit; CSA LR 40350) TKM8 2 600 3 TKM12 250 .22 42 10 — 20 <D 22 33 lb/1 5"/16 5'/2 500 39 lb/1 2 1% 3 THKM12 2 250 3 — 65 35 40® — — — 8'/4 2 % % 5/2 SQ/IB 1% 3 UL listed with poles in series for 500 Vdc ungrounded battery applications. © All UL listed as HACR type. ® 10 amp not UL listed. Data subject to change without notice ® UL listed/CSA Certified for 10kA @ 347 Vac (TED) and 18kA@ 347V (THED). Also rated 10kA @ 480V but not UL listed. © UL listed at 10,000 amps. ® Discontinued © Also 10,000 amps at 500 Volts dc. Not UL listed. 1999 Issue 38 lb/1 41VMW1 33 lb/1 39 lb/1 38 lb/1 41 14 lb/1 500 Vdc on TJJ only. (continued on page 4-8) 4-7