DATA SHEET
OLF600: High-Speed Schmitt Trigger Hermetic Surface Mount
Optocoupler
Features
 Performance guaranteed over –55 °C to +125 °C ambient
temperature range
2
8
Cathode
VCC
 Guaranteed minimum CMR transient immunity
>1000 V/μs @ 300 VCM
7
VO
 1000 VDC electrical isolation
 Microprocessor-compatible drive
 On/off threshold hysteresis
 Fast switching: tr, tf = 10 ns typical
1
Anode
6
GND
Y1088
Description
Figure 1. OLF600 Block Diagram
The OLF600 has an LED and an integrated high-speed detector
mounted and coupled in a hermetic SMT that provides 1000 VDC
electrical isolation between the input and output.
The light from the LED is collected by the photodiode in the
integrated detector. The integrated detector incorporates a
Schmitt trigger, which provides hysteresis for noise immunity and
pulse shaping and an open collector output. Typical propagation
delay of this product is 170 ns. The Common Mode Rejection
(CMR) transient immunity is greater than 1000 V/μs.
Figure 1 shows the OLF600 functional block diagram. Table 1
provides the OLF600 absolute maximum ratings. Table 2 provides
the OLF600 electrical specifications.
Figures 2 and 3 illustrate the OLF600 typical performance
characteristics. Figure 4 shows the OLF600 switching test circuit.
Figure 5 provides the OLF600 package dimensions.
Device surface mounting is achieved with reflow soldering or
conductive epoxies.
Isolink, Inc. • Phone [408] 946-1968 • Fax [408] 946-1960 • sales@isolink.com • www.isolink.com
203247A • Isolink Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 8, 2014
1
DATA SHEET • OLF600: HIGH-SPEED SCHMITT TRIGGER HERMETIC SURFACE MOUNT OPTOCOUPLER
Table 1. OLF600 Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Minimum
Maximum
Units
Coupled
Input to output isolation voltage (Note 2)
VDC
–1500
+1500
V
Storage temperature range
TSTG
–65
+150
C
Operating temperature range
TA
–55
+125
C
+240
C
PD
+250
mW
Average input current
IDD
20
mA
Reverse voltage
VR
5
V
Power dissipation
PD
40
mW
40
mA
Mounting temperature range (3 minutes maximum)
Total power dissipation
Input Diode
Output Detector
Peak output current
Supply voltage
VCC
18
V
Output voltage
VOUT
18
V
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to the device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
Note 2: Measured between pins 1, 2, and 6 shorted together, and pins 3, 4, and 5 shorted together. TA = 25°C and duration = 1 s.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This
device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the
human body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at
all times.
Isolink, Inc. • Phone [408] 946-1968 • Fax [408] 946-1960 • sales@isolink.com • www.isolink.com
2
July 8, 2014 • Isolink Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203247A
DATA SHEET • OLF600: HIGH-SPEED SCHMITT TRIGGER HERMETIC SURFACE MOUNT OPTOCOUPLER
Table 2. OLF600 Electrical Specifications (Note 1)
(TA = –55 C to +125 C, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Minimum
Typical
Maximum
Units
10
mA
0.5
V
250
μA
Threshold Current, ON
IF(ON)
VCC = 15 V, RL = 680 Ω
Hysteresis ratio
IF(OFF)
IF(ON)
VCC = 15.0 V, RL = 680.0 Ω
0.8
Low level output voltage
VOL
VCC = 15.0 V, RL = 680.0 Ω, IF = 10.0 mA
0.3
High level output current
IOH
VCC = VO =15 V, IF = 0 mA
High level
IccH
VCC = 15 V, IF = 0 mA
9
15
mA
Low level
ICCL
VCC = 15 V, IF = 5 mA
9
16
mA
1.6
Supply current:
Input:
Forward voltage
VF
IF = 10.0 mA
2.4
V
Reverse current
IR
VR = 3 V
10
μA
To output leakage current (Note 2)
II_O
RH ≤ 50%, TA = 25 °C, VI_O = 1500 VDC
1
μA
Propagation delay times:
High to low
tPHL
IF = 5 mA, VCC = 15 V, RL = 680 Ω, TA = 25 °C
300
ns
Low to high
tPLH
IF = 5 mA, VCC = 15 V, RL = 680 Ω, TA = 25 °C
300
ns
Fall
tf
IF = 5 mA, VCC = 15 V, RL = 680 Ω, TA = 25 °C
10
ns
Rise
tr
IF = 5 mA, VCC = 15 V, RL = 680 Ω, TA = 25 °C
10
ns
High output
CMH
IF = 0 mA, VCM = 300 V peak, RL = 680 Ω,
VCC = 15 V, TA = 25 °C
1000
>10,000
V/μs
Low output
CML
IF = 5 mA, VCM = 300 V peak, RL = 680 Ω,
VCC = 15 V, TA = 25 °C
1000
>10,000
V/μs
Times:
Common mode transient immunity:
Note 1: Performance is guaranteed only under the conditions listed in the above table.
Note 2: Measured between pins 1, 2, and 6 shorted together, and pins 3, 4, and 5 shorted together. TA = 25°C and duration = 1 s.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
203247A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 8, 2014
3
DATA SHEET • OLF600: HIGH-SPEED SCHMITT TRIGGER HERMETIC SURFACE MOUNT OPTOCOUPLER
Typical Performance Characteristics
400
2.2
300
IF = 10 mA
Propagation Delay (ns)
Forward Voltage (V)
2.0
1.8
1.6
1.4
VCC = 15 V
RL = 680 Ω
IF = 5 mA
tPHL
tPLH
200
100
1.2
–75 –50 –25
0
–75 –50 –25
0 +25 +50 +75 +100 +125 +150
Ambient Temperature (°C)
Figure 3. Propagation Delay vs Temperature
Figure 2. Forward Voltage vs Temperature
Input IF
0 +25 +50 +75 +100 +125 +150
Ambient Temperature (°C)
+15 V
IF
IF = 5.0 mA
IF = 6.5 mA
RL
50%
V0
VOUT
0.1 μF
IF Monitor
1.5V
tPHL
tPLH
50 Ω
Shield
K053a
Figure 4. OLF600 Switching Test Circuit
Isolink, Inc. • Phone [408] 946-1968 • Fax [408] 946-1960 • sales@isolink.com • www.isolink.com
4
July 8, 2014 • Isolink Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203247A
DATA SHEET • OLF600: HIGH-SPEED SCHMITT TRIGGER HERMETIC SURFACE MOUNT OPTOCOUPLER
Y1089
Figure 5. OLF600 Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
203247A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 8, 2014
5
DATA SHEET • OLF600: HIGH-SPEED SCHMITT TRIGGER HERMETIC SURFACE MOUNT OPTOCOUPLER
Ordering Information
Model Name
OLF600: High-Speed Schmitt Trigger Hermetic Surface Mount Optocoupler
Manufacturing Part Number
OLF600
Copyright © 2014 Isolink, Inc. All Rights Reserved.
Information in this document is provided in connection with Isolink, Inc. (“Isolink”) products or services. These materials, including the information contained herein, are provided by Isolink as a
service to its customers and may be used for informational purposes only by the customer. Isolink assumes no responsibility for errors or omissions in these materials or the information contained
herein. Isolink may change its documentation, products, services, specifications or product descriptions at any time, without notice. Isolink makes no commitment to update the materials or
information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Isolink assumes no liability for any materials, products or information
provided hereunder, including the sale, distribution, reproduction or use of Isolink products, information or materials, except as may be provided in Isolink Terms and Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. ISOLINK DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. ISOLINK SHALL
NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST
REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY
OF SUCH DAMAGE.
Customers are responsible for their products and applications using Isolink products, which may deviate from published specifications as a result of design defects, errors, or operation of products
outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Isolink assumes no liability for applications
assistance, customer product design, or damage to any equipment resulting from the use of Isolink products outside of stated published specifications or parameters.
Isolink is a trademark of Isolink Inc. in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners.
Isolink, Inc. • Phone [408] 946-1968 • Fax [408] 946-1960 • sales@isolink.com • www.isolink.com
6