Circuit Breaker Lockout Reference Guide WWW.BRADYID.COM/LOCKOUT cover.indd 1 2/1/07 2:45:03 PM Circuit Breaker Lockout Devices EZ Panel LocTM ❥ ❥ Works on wide range of breakers, including single- and multi-pole configurations Makes use of unique lock rail system, providing the following benefits: ❥ Allows panel door to be closed even when lockouts are in place ❥ Accommodates multiple locks, facilitating group lockout activity without hasps ❥ Keeps weight off the breakers, protecting delicate electrical components from damage ❥ Positions locks and tags outside the panel, making sure lockout activity is clearly visible to anyone in the area ❥ Patent No. 6,727,441 How EZ Panel Loc System Works 1 4 Pass plastic key through lock rail and attach lock, preventing key from sliding down cable and opening lockout device. Lockout device is unlocked by inserting and turning the red plastic key. 2 Peel liner off bottom of lock rail, exposing super-bond adhesive. Permanently affix to any location on the panel. No drilling required! 5 For group lockouts, run key through multiple loops in lock rail and apply locks. No hasps required! 3 Attach the lockout device to the breaker and snap into locked position. 6 Low-profile lockouts allow panel doors to be closed on most breaker panels. Covers Most 120V – 277VBreakers! ❥ The EZ Panel Loc™ System includes two types of lockout devices, accommodating an exceptionally wide range of breaker models. SNAP-ON For use on Square D NQO and other breakers that have a hole in the switch tongue. Just align pins with hole and snap closed. Pins prevent switch from being thrown. CircBreakerxref FINAL v2.indd 2 CLAMP-ON For use on breakers that do not have a hole in the switch tongue, including multipole breakers with tie-bars. Turn thumbscrew to clamp lockout securely onto switch, then snap the cover closed to prevent thumbwheel from being loosened. 2/6/07 2:37:10 PM Circuit Breaker Lockout Devices TM EZ Panel Loc™ “No Shackle” EZ Panel Locks The EZ Panel Loc system can be used with most padlocks. A shackle-less padlock designed specifically for use with the EZ Panel Loc key is also available. This is especially useful when lockout devices will be kept at the panel in accordance with NEC regulations (see below). Everything you need to lockout breakers is kept conveniently right at the point of need! “The provisions for locking or adding a lock to the disconnecting means shall be permanently installed on or at the switch or circuit breaker used as the disconnecting means.” NEC 2002, Article 430.102(B) Motor Spacing Gasket For low profile panels, a spacing gasket can be installed, pushing out the panel frame and adding an additional 3/8” of clearance between the panel surface and the door. Self-adhesive backing makes installation quick and easy. Dimensions: 3/8”D, 1”W, 15’L. Snap On Clamp On • Lockout devices constructed of high-impact Isoplast polymers • Cables are 2-ft. in length • Lock rails made of durable isoplast polymers with acrylic adhesive backing • Lock rails available in 4" or 8" lengths (containing 7 or 15 lock loops) • Patent No. 6,727,441 • Also available with nonconductive nylon cables. Call for information. Snap-On Style Clamp-On Style Description Snap-On Lockout Device Clamp-On Lockout Device 4” Lock Rail 8” Lock Rail No-Shackle Lock Spacing Gasket 1 Per Pkg 51252 51254 51256 51258 51261 89256 A 0.90" 0.95" Outer Dimensions (in.) B 1.88" 2.56" 6 Per Pkg 65815 65810 65814 51260 51263 NA C 0.74" 0.74" Switch Clearance (in.) D E 0.40" 0.35" 0.35" 0.42" www.bradyid.com/lockout Technical Information 3 CircBreakerxref FINAL v2.indd 3 2/6/07 2:37:15 PM Circuit Breaker Lockout Devices 120V Snap-On Breaker Lockout • • • • • • Designed for 120V breakers that have holes in the switch tongue Quick and easy – just snap in place and apply lock! Dual cavities accommodate different size switch tongues Accepts locks shackles up to 9/32" in diameter Dimensions: 0.83"H x 0.35"W x 2.15"L Patent No. 5,122,624 Catalog Number 65387 65688 Qty 1/pkg 6/pkg Clamp-On Breaker Lockouts • • • • Extremely versatile – works on wide range of single-pole and internal-trip multi-pole breakers! Two sizes, one for 120/277V breakers and one for 480/600V breakers Made of rugged polypropylene and impact modified nylon Use thumbscrew to clamp lockout securely onto switch tongue, then pull cover over thumbscrew and lock in place to prevent clamp from being loosened • New blade design provides tighter grip with less torque on thumb screw • Accepts locks shackles up to 9/32" in diameter • Patent No. 5,500,495 Catalog No. 65396 65965 65397 65966 The Brady Clamp-On Circuit Breaker Lockout works on an extremely wide range of breakers. Description 120/277V Clamp-On Breaker Lockout 120/277V Clamp-On Breaker Lockout 480/600V Clamp-On Breaker Lockout 480/600V Clamp-On Breaker Lockout Qty 1/pkg 6/pkg 1/pkg 6/pkg Cleats for Clamp-On Breaker Lockouts • • • • • Step 1 Step 2 Step 3 Use in conjunction with clamp-on breaker lockouts (sold above) Easily clips onto the bottom of the lockout body Assures positive restraint for breakers with long, sliding switch throws Patent No. 5,500,495 Standard package: 6 cleats Catalog No. 65404 65406 Description Cleats For 120/277V Lockout Cleats For 480/600V Lockout Qty 6/pkg 6/pkg Universal Multi-Pole Breaker Lockout • Single device works with most major multi-pole breakers that employ a tie-bar • Made of durable impact-modified nylon • Compatible with GE, ITE, Sylvania, Challenger, Bryant, Westinghouse, General Switch Co., and more! • Use thumbscrew to clamp lockout securely over tie bar, then insert lock to prevent clamp from being loosened • Patent No. 5,300,740 Catalog Number 66321 66320 Qty 1/pkg 6/pkg Universal Multi-Pole Lockout works with most two or three pole breakers utilizing a tie-bar. Oversized Breaker Lockout • • • • Oversized 480/600V frame lockout fits breaker switches up to 21/4" wide and 7/8" thick Made of durable polypropylene and glass filled-impact-modified nylon New blade design gets better grip, works on even more breaker models! Patent #5,500,495 Catalog Number 65329 65321 CircBreakerxref FINAL v2.indd 4 Qty 1/pkg 6/pkg 2/6/07 2:37:17 PM Circuit Breaker Lockout Devices 480-600V Breaker Blocker • Perfect for locking out oversized and irregularly shaped switches • Self-adhesive backed rails are permanently installed into an electrical panel – simply clean panel surface and adhere – no drilling required! • Blocking bars (red and green) are 71/2" long • Red blocking bar indicates locked off, green bar indicates locked on • Patent No. 6,469,264 Breaker Blocker Kit Catalog No. Description 90891 Breaker Block Kit Kit includes 2 yellow mounting rails, 1 red blocking bar, 1 green blocking bar and 3 alcohol wipes. Breaker Blocker Components Catalog No. 90892 90893 51264 51265 Description 7.6” Red Blocking Bar 7.6” Green Blocking Bar 4” Yellow Mounting Rails Blocking Bar Holder Qty 5/pack 5/pack 2/pack 5/pack Tie-Bar Pin-Out Standard Pin-In Standard Pin-Out Wide 4 Different types: POS PIS POW TBLO • A safe and effective method for locking out miniature circuit breakers, commonly used in European and Asian equipment • Miniature Breaker Lockouts requires NO TOOLS to install! The Lockout easily installs with the aid of a push button. The Tie Bar Style Lockout has a convenient thumb wheel for quick application. • Available for single and multi-pole breakers • Recommended to lock with lightweight Brady Safety padlocks (see page 18) or other padlocks, the lockouts can take padlocks with a shackle diameter up to 9/32" • Material: Glass-filled nylon • Available in 1 or 6 packs • Patent No. 6,844,512 Pin Out Standard Pin In Standard Pin Out Wide Tie Bar Lockout Catalog No. 90844 90845 90847 90848 90850 90851 90853 90854 Type POS POS PIS PIS POW POW TBLO TBLO Qty 1 6 1 6 1 6 1 6 www.bradyid.com/lockout Miniature Circuit Breaker Lockouts 5 CircBreakerxref FINAL v2.indd 5 2/6/07 2:37:18 PM Circuit Breaker Lockout Kits Personal Breaker Lockout Pouch ◗ Personal Breaker Lockout Pouch • Pouch contains 1 each of our most popular circuit breaker lockouts • Covers 120v/277v and 480/600v breakers in single- and multi-pole configurations. • Components: • 1 120/277V Clamp-On Breaker Lockout w/cleat (65396) • 1 480/600V Clamp-On Breaker Lockout w/cleat (65397) • 1 Universal Multipole Breaker Lockout (66321) • 2 1” Group Lockout Hasps (65375) • 2 Heavy Duty Lockout Tags (65520) w/ Nylon Cable Ties • 1 Lockout Belt Pouch (51172) Catalog No. 105966 105967 105968 Description Personal Breaker Lockout Pouch (Kit) Kit w/ 2 Keyed-Alike Safety Padlocks Kit w/ 2 Keyed-Alike Steel Padlocks Personal Breaker Lockout Kit ◗ Personal Breaker Lockout Kit Catalog No. 105963 105964 105965 Description Personal Breaker Lockout Kit Kit w/ 3 Keyed-Alike Safety Padlocks Kit w/ 3 Keyed-Alike Steel Padlocks • Tool box contains 2 each of our most popular breaker lockouts • Covers 120v/277v and 480/600v breakers in single- and multi-pole configurations • Components: • 2 120/277V Clamp-On Breaker Lockouts w/ Cleats (65396) • 2 480/600V Clamp-On Breaker Lockouts w/ Cleats (65397) • 2 Universal Multipole Breaker Lockouts (66321) • 3 1” Red Lockout Hasps (65375) • 3 Heavy Duty Lockout Tags (65520) w/ Nylon Cable Ties • 1 Small Lockout Toolbox (105905) • 1 Toolbox (105905) Personal Electrical Lockout Kit • Provides lockouts for use on most circuit breakers, electrical plugs and disconnect switches. • Components: • 1 Mini Cable Lockout (50940) • 1 3-in-1 Plug Lockout (PLO23) • 2 120/277V Clamp-On Breaker Lockouts w/ Cleats (65396) • 1 480/600V Clamp-On Breaker Lockout w/ Cleat (65397) • 2 Universal Multipole Breaker Lockout (66321) • 1 Oversized Breaker Lockout (65329) • 3 1” Group Lockout Hasps (65375) • 3 Heavy Duty Lockout Tags (65520) w/ Nylon Cable Ties • 1 Medium Lockout Toolbox (105906) Catalog No. 105960 105961 105962 Description Personal Electrical Lockout Kit Kit w/3 Keyed-alike Safety Padlocks Kit w/3 Keyed-alike Steel Padlocks For more information on Brady Safety padlocks, see page 15. CircBreakerxref FINAL v2.indd 6 2/6/07 2:37:19 PM Circuit Breaker Lockout Cross Reference Guide Standard Breaker Lockouts Airpax Allen Bradley Allen Bradley Allen Bradley Allen Bradley Allen Bradley Allen Bradley Allen Bradley Allen Bradley Allen Bradley Allen Bradley Allen Bradley Allen Bradley Allen Bradley Allen Bradley Allen Bradley ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB x Breaker Type Airpax 1492-CB1F 1492-CB2F 1492-CB3F 1492-CB1G 1492-CB2G 1492-CB3G 1492-CB1H 1492-CB2H 1492-CB3H 1492-CB1DF 1492-CB1DG 1492-CB1DH 1492-CB2DF 1492-CB2DG 1492-CB2DH JS S1 S3 F362 F364 F374 E221 E222 E241 E271 E242 E272 E243 E273 E244 E274 S201-B S202-B S203-B S204-B S201-C S202-C S203-C S204-C S201-D S202-D S203-D S201-K S202-K S203-K S204-K S201P-K S202P-K S203P-K S222-K S221 S222 S223 S224 S251 S252 S253 S261-B S262-B S263-B S264-B S261-C S262-C S263-C S264-C S261-D S262-D S263-D S271-K S272-K S273-K S274-K S281-K S282-K S283-K S281UC-K S282UC-K S283UC-K S201P-Z S202P-Z S203P-Z S201U-K # of Poles 1 1 2 3 1 2 3 1 2 3 1 1 1 2 2 2 2-3 3 3 2 4 4 1 2 1 1 2 2 3 3 4 4 1 2 3 4 1 2 3 4 1 2 3 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 1 2 3 4 1 2 3 4 1 2 3 1 2 3 4 1 2 3 1 2 3 1 2 3 1 Mini Circuit Breaker Lockouts 120/277V Clamp On (no hole) 480/600V Clamp On (no hole) Oversize 480/600V Universal Multi-pole (tie bar) Snap On (SQD QO) Clamp On (Universal) Pin Out Standard Pin In Standard Pin Out Wide Multi-pole w/ Tie Bar 65387 65396 65397 65329 66321 51252 51254 90844 90847 90850 90853 X* X X X X X X X X X X X X X X X X** X X** X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X www.bradyid.com/lockout Circuit Breaker Manufacturer EZ Panel Loc™ 120V Snap On (w/ hole) Denotes Compatiblity Don’t see your circuit breaker? Call us at 888-272-3946 CircBreakerxref FINAL v2.indd 7 7 2/6/07 2:37:21 PM Circuit Breaker Lockout Cross Reference Guide Standard Breaker Lockouts Circuit Breaker Manufacturer ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB American Ckt. Bkr. American Ckt. Bkr. AEG American Switch Bryant Bryant Buschmat Challenger Challenger Challenger Challenger Challenger Clipsal Crouse Hinds Cutler Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer x Breaker Type S202U-K S203U-K S204U-K S201UP-K S202UP-K S203UP-K S204UP-K S201U-Z S202U-Z S203U-Z S204U-Z S201UP-Z S202UP-Z S203UP-Z S204UP-Z F202AC F672 F204AC F674 S281-Z S282-Z S283-Z S281UC-Z S282UC-Z S283UC-Z S501-B S502-B S503-B S501-C S502-C S503-C S501-D S502-D S503-D S501-K S502-K S503-K S501UC-B S502UC-B S503UC-B S504UC-B S501UC-K S502UC-K S503UC-K S504UC-K NEF NJJ E82S C BR BR S46 C C CDK LM NEJ 4CB MP BA BAB BAB BD BR BR BRH BRH BRHH CC CH CH CHH CH2 CHB CHB CHKD CHLD CHMDL CHND CHP CHP CHQ CHQ CHSW Denotes Compatiblity CircBreakerxref FINAL v2.indd 8 # of Poles 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 2 2 4 4 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 4 1 2 3 4 3 3 2 1 1 2-3 1 1 2-3 2-3 1 1-2 1-3 2 1 1 2-3 1 1 2-3 1 2-3 2 3 1 2-3 3 4 1 2-3 2-3 2-4 2-3 2-4 1 2-3 1 2 2-3 EZ Panel Loc™ Mini Circuit Breaker Lockouts 120V Snap On (w/ hole) 120/277V Clamp On (no hole) 480/600V Clamp On (no hole) Oversize 480/600V Universal Multi-pole (tie bar) Snap On (SQD QO) Clamp On (Universal) Pin Out Standard Pin In Standard Pin Out Wide Multi-pole w/ Tie Bar 65387 65396 65397 65329 66321 51252 51254 90844 90847 90850 90853 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X* X** X X X X X X X X X X X X X X X X X X X* X X X X X X X X X X X X X X X X X X X X X X X X X X X X* X X X X X X* X X X X X X X X X X X X** X X X X X X X X X X X X * - Cleat (65404) accessory required see page 4 ** - Cleat (65406) accessory required see page 4 2/6/07 2:37:22 PM Circuit Breaker Lockout Cross Reference Guide Standard Breaker Lockouts Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Breaker Type CKD CL CL CLD CLDC CMDL CND CNDC CSR DK E125B E125E E125H E125S ED EDC EDH EFH EGB EGE EGS EHC EHD FB FC FD FDB FDC FS GB GC GD GDB GHB GHBGFEP GHC GHCGFEP HBAW HBAW HBAX HBAX HFD HGHB HGHC HJD HKD HLD HMCP HMDL HMDLB HMPL HND HQP HQP JD JDB JDC KD KDB KDC LA LD LDB LDC LH LHB LJ MA MC MD MDL MDS NB ND NDC OPTIM PB QBGF QBGF QBGFEP QBGFEP QBHGF QBHGFEP # of Poles 2-3 1 2 2-4 2-4 2-3 2-4 2-4 1 2-3 1-4 1-4 1-4 1-4 2-4 2-4 2-4 1-4 1-4 1-4 1-4 1-4 1-4 2-3 1-4 1-4 2-4 2-4 2-3 1-3 1-3 1-3 1-3 1-3 1 1-3 1 1 2-3 1 2-3 1-4 1 1 2-4 2-4 2-4 2-3 2-3 2-3 3 2-4 1 2 2-4 2-3 2-4 2-4 2-4 2-4 2-3 2-4 2-3 2-4 3 3 3 2-3 2-3 2-3 2-3 2-3 2-3 2-4 2-4 3 2-3 1 2 1 2 1 1 Mini Circuit Breaker Lockouts 120/277V Clamp On (no hole) 480/600V Clamp On (no hole) Oversize 480/600V Universal Multi-pole (tie bar) Snap On (SQD QO) Clamp On (Universal) Pin Out Standard Pin In Standard Pin Out Wide Multi-pole w/ Tie Bar 65387 65396 65397 65329 66321 51252 51254 90844 90847 90850 90853 X X X X X X X X X X X** X** X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X** X** X X X X X X X X X X X X X X X X X X X X X X X** X** X X X X X** X** X** X X X X X X X Don’t see your circuit breaker? Call us at 888-272-3946 CircBreakerxref FINAL v2.indd 9 www.bradyid.com/lockout Circuit Breaker Manufacturer EZ Panel Loc™ 120V Snap On (w/ hole) 9 2/6/07 2:37:24 PM Circuit Breaker Lockout Cross Reference Guide Standard Breaker Lockouts Circuit Breaker Manufacturer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer Cutler-Hammer E-T-A E-T-A FAZ Fed. Pacific Elec. Fed. Pacific Elec. Fed. Pacific Elec. Fed. Pacific Elec. Fed. Pacific Elec. Fed. Pacific Elec. Fed. Pacific Elec. Fed. Pacific Elec. Fed. Pacific Elec. Fed. Pacific Elec. Fed. Pacific Elec. Fed. Pacific Elec. Fed. Pacific Elec. Frank Adams FUJI Electric FUJI Electric FUJI Electric FUJI Electric FUJI Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric x Breaker Type QBHW QBHW QC QC QCD QCD QCGF QCGFEP QCHGF QCHGFEP QCHW QCHW QHCW QHCW QHCX QHCX QHPW QHPW QHPX QHPX QPGF QPGF QPGFEP QPGFEP QPHGF QPHGFEP QPHW QPHW WME WMF WMH WMM WMN WMS 911220G 911225 C16 2B BAB NA-single NA-tie bar NB NBH GFI NE/NEF NEJ NFJ NJJ NJL NM NP-single P EA53B EA203B BU-ESB BU-ESA BU-FSB V EH400 HQC SED SEH SEL SEP SFH SFL SFP SGD SGH SGL SGLA SGP SRPG TB TBC TE TEB TED TEF TEL TEML TEY TF TFC TFJ Denotes Compatiblity CircBreakerxref FINAL v2.indd 10 # of Poles 1 2-3 1 2-3 1 2-3 1 1 1 1 1 2-3 1 2-3 1 2-3 1 2-3 1 2-3 1 2 1 2 1 1 1 2-3 1-3 1-3 1-4 1-4 1-4 1-4 2 1 1-4 2 1 3 2 1 1 1-3 1-3 1-3 1-3 1-3 1-3 1 1 3 3 3 3 3 1-3 3 3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 3 2 2 1-3 1-3 1-3 1-3 3 3 1-3 1-3 3 2-3 EZ Panel Loc™ Mini Circuit Breaker Lockouts 120V Snap On (w/ hole) 120/277V Clamp On (no hole) 480/600V Clamp On (no hole) Oversize 480/600V Universal Multi-pole (tie bar) Snap On (SQD QO) Clamp On (Universal) Pin Out Standard Pin In Standard Pin Out Wide Multi-pole w/ Tie Bar 65387 65396 65397 65329 66321 51252 51254 90844 90847 90850 90853 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X** X* X X* X* X X X X X X X X X X X X* X* X* X* X* X X X X X X X X X X X X X X X X X X X X X X X X X X X* X* X* X* X* X* X* X* X X X* X X X X X X X X X X X X * - Cleat (65404) accessory required see page 4 ** - Cleat (65406) accessory required see page 4 2/6/07 2:37:25 PM Circuit Breaker Lockout Cross Reference Guide Standard Breaker Lockouts General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric GE Vynckier GE Vynckier Hager Hager Hager Heinemann Heinemann Heinemann Kapp Legrand Legrand Legrand Legrand Legrand Lemag Merlin Gerin Merlin Gerin Merlin Gerin Merlin Gerin Merlin Gerin Merlin Gerin Merlin Gerin Merlin Gerin Merlin Gerin Merlin Gerin Merlin Gerin Merlin Gerin Merlin Gerin Merlin Gerin Breaker Type TFK TFL THED THEF THFK THHQB THHQB-A THHQB-S THHQC THHQC-A THHQC-S THHQL THHQL-A THHQL-S THJK4 THJK6 THKM12 THKM8 THLC1 THQB THQB GF THQB-A THQB-S THQC THQC-A THQC-AL THQC-S THQD THQDBL THQL THQL-A THQL-S TJ2 TJ4 TJC TJD TJJ TJK TJS TK4V TKC TKM TKMA8 TQB TQB-A TQB-S TQC TQC-A TQC-S TQD TQL TQL TQL-A TQL-S V Series E Series G 453717 MW216A MW620A LB LF LJ LS68 04302 06469 01908 01935 01980 SD62 B100A C32N C45AD C60a C60H C60N C80A NC100H NC125H NC100L NC100LH NC100L MA NC100N C801N # of Poles 2-3 3 1-3 1-3 2-3 2-3 1 1 1-3 1 1 2-3 1 1 2-3 2-3 2-3 2-3 3 2-3 1-2 1 1 2-3 1 2-3 1 2-3 3 2-3 1 1 2-3 3 2-3 2-3 2-3 2-3 2-3 3 3 2-3 3 2-3 1 1 2-3 1 1 2-3 1-3 2-3 1 1 1-4 1-4 1-3 3 2 4 1 1 1 1 2 3 1 2 3-4 1 2 1-3 3 1-4 1-4 1-4 3 1-3 1-3 1-4 1-4 3 1-4 3 Mini Circuit Breaker Lockouts 120/277V Clamp On (no hole) 480/600V Clamp On (no hole) Oversize 480/600V Universal Multi-pole (tie bar) Snap On (SQD QO) Clamp On (Universal) Pin Out Standard Pin In Standard Pin Out Wide Multi-pole w/ Tie Bar 65387 65396 65397 65329 66321 51252 51254 90844 90847 90850 90853 X X X* X* X X X X X X X X X X X X X X X X X X X X X X X X X** X** X X X* X X X X X X X X X X* X X X X X** X X X X X X X X X X X X X X X* X X** X** X** X** X X* X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X* X* X* X X X X X X X X X X X X X X X X X X X X X X X Don’t see your circuit breaker? Call us at 888-272-3946 CircBreakerxref FINAL v2.indd 11 www.bradyid.com/lockout Circuit Breaker Manufacturer EZ Panel Loc™ 120V Snap On (w/ hole) 11 2/6/07 2:37:26 PM Circuit Breaker Lockout Cross Reference Guide Standard Breaker Lockouts Circuit Breaker Manufacturer Merlin Gerin Merlin Gerin Merlin Gerin Merlin Gerin Proteus Proteus Proteus Proteus Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE x Breaker Type C1251N CE104N CK1200NA CJ BSEN60947-3 AC22BS5419 C16 C6 5SX11 5SX12 5SX13 5SX21 5SQ11 5SQ12 5SQ13 5SQ16 5SN22 BL BL BLF-GFI BLH BLH BQ BQ BQCH BQD BQH BQH CED6 CFD6 CFD6-ETI CJ3 CJD6 CJD6-ETI CLF CMD6 CMD6-ETI CND6 CPD6 CQD E2 E4 ED ED4 ED6 ED6-ETI EE3 EH3 EQP EQT QF ET FD6A FJ2-B FJ3 FJ6 FXD6A FXD6-ETI GF HBL HBL HBQ HBQ HE4 HED4 HED6 HFD6 HFXD6 HHED6 HHFD6 HHJD6 HHJXD6 HJD6 HJXD6 HMD6 HMXD6 HN3 HND6 HNXD6 HPD6 HPXD6 HQJ2-H HQP HQP HQPP Denotes Compatiblity CircBreakerxref FINAL v2.indd 12 # of Poles 3 3 3 3 2 2 1 1-3 1 2 3 1 1 2 3 4 2 1 2-3 2 1 2-3 1 2-3 1-3 1-3 1 2-3 2-3 2-3 2-3 2-3 2-3 2 3 3 3 3 1-3 1-3 1-3 1-3 1-3 1-3 3 3 3 4 3 3 2-3 2-3 2 2 2-3 2-3 1 1 2-3 1 2-3 1-3 1-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2 2-3 2-3 3 3 3 1 2-3 1 EZ Panel Loc™ Mini Circuit Breaker Lockouts 120V Snap On (w/ hole) 120/277V Clamp On (no hole) 480/600V Clamp On (no hole) Oversize 480/600V Universal Multi-pole (tie bar) Snap On (SQD QO) Clamp On (Universal) Pin Out Standard Pin In Standard Pin Out Wide Multi-pole w/ Tie Bar 65387 65396 65397 65329 66321 51252 51254 90844 90847 90850 90853 X X* X X** X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X** X** X X X X X X X X X* X X X X X X X* X* X X* X* X X X X X X X X X X X X X X X X X** X** X X** X** X** X X X X X X X X X X X X X X** X** X X X** X X X X X X X X X X X X X X X X X X X X X * - Cleat (65404) accessory required see page 4 ** - Cleat (65406) accessory required see page 4 2/6/07 2:37:27 PM Circuit Breaker Lockout Cross Reference Guide Standard Breaker Lockouts Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Siemans ITE Simplex Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Breaker Type HQPP HQPPH HRD6 HRXD6 JD2 JD6-A JJ3 JJ6 JL3 JXD2-A JXD6-A KM3 LL3 LL6 LXD6-ETI MD6 MXD6 MXD6-ETI ND6 NH3-F800 NXD6 PD6 PXD6 QJ2 QJ2-H QJH2 QP QP QP1 QPH QPH QPP QPP QPPH QPPH RD6 RXD6 SCMD6 SCND6 SHLD6-A SHMD6 SHND6 SMD6 SND6 SHPD6 SPD6 3VF3 NX EDB EGB EH4 EHB EHB EJB EZ FA FAL FC FCL FDA FGA FH FHL FHL-DC FHP FI FIL FY GJL KA KAL KAP KC KCL KH KHL KI KIL LA LAL LAP LC LCP LH # of Poles Mini Circuit Breaker Lockouts 120/277V Clamp On (no hole) 480/600V Clamp On (no hole) Oversize 480/600V Universal Multi-pole (tie bar) Snap On (SQD QO) Clamp On (Universal) Pin Out Standard Pin In Standard Pin Out Wide Multi-pole w/ Tie Bar 65387 65396 65397 65329 66321 51252 51254 90844 90847 90850 90853 2-3 2 3 3 3 2-3 X X X X X X X 3 3 2-3 2-3 3 3 3 3 2-3 2-3 2-3 2-3 2-3 3 3 2-3 2-3 2-3 1 2-3 1 1 2-4 1 2-3 1 2-3 3 3 3 3 3 3 3 3 3 3 3 3 3 1-3 1-3 1-3 1-3 2-3 1-3 3 1-3 1-3 3 2-3 3 1-3 1-3 3 3 3 3 1 3 2-3 2-3 X X X X X X X X X X X X X X X X X X X* X* X* X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X** X X X X X X X X X X X X X X* X* X* X* X X X X* X* X* X* X* X* X* X* X* X* X 2-3 2-3 2-3 3 2-3 2-3 2-3 2-3 3 3 3 2-3 X* X* X* X* X* X* X** X** X** X X X X X** Don’t see your circuit breaker? Call us at 888-272-3946 CircBreakerxref FINAL v2.indd 13 www.bradyid.com/lockout Circuit Breaker Manufacturer EZ Panel Loc™ 120V Snap On (w/ hole) 13 2/6/07 2:37:28 PM Circuit Breaker Lockout Cross Reference Guide Standard Breaker Lockouts Circuit Breaker Manufacturer Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Square D Sursum Sylvania GTE Sylvania GTE Thomas & Betts Toshiba Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse x Breaker Type LHL LHP L2 LXL MA MA MAL MH MH MHL ML-1 ML-3 MXL Q1B Q1L Q2 Q2H Q2L Q2MT Q4 Q4L QO QO QOB QOB QOB-H QOB-VH QOB-VH QO-H QOM1-VH QOM2-VH QO-SWN QOU QOU QOU w/tie bar QO-VH QO-VH QYU Y1 EA53 QC Type C F Frame E225B BA w/tie bar BA BAB BR BR w/tie bar BRH w/tie bar CA DA DK EB ED EH EHB EHD FA FB FD FDB FDC FP GB GBH GHB GR HBAW HBAX HCA HFB HFD HKD HLA HLB HMC HMCP HNC HQNP HQP JA JB JD Denotes Compatiblity CircBreakerxref FINAL v2.indd 14 # of Poles EZ Panel Loc™ Mini Circuit Breaker Lockouts 120V Snap On (w/ hole) 120/277V Clamp On (no hole) 480/600V Clamp On (no hole) Oversize 480/600V Universal Multi-pole (tie bar) Snap On (SQD QO) Clamp On (Universal) Pin Out Standard Pin In Standard Pin Out Wide Multi-pole w/ Tie Bar 65387 65396 65397 65329 66321 51252 51254 90844 90847 90850 90853 X** X** X X X X 3 3 3 2-3 3 3 2-3 2-3 2-3 3 3 3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 1 2-3 1 2-3 2 1 2-3 2 2 2 2-3 1 2-3 2-3 1 2-3 1 X** X X X X** X X** X X X X X* X* X* X* X X X** X** X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 3 2 2 1-3 3 2-3 1-3 1-3 1-3 2-3 2-3 X X X X X* X X X X X X X X X X X X X X X X X* X X 1-3 1-3 1-3 1-3 3 2-3 1-4 2-4 2-4 3 1-3 1-3 1-3 3 1 1 3 1-3 1-4 3 X* X X X* X X* X* X X X X X X X X X X X X X** X X X X X X X X X X X X* X* X X X X X X X X X X X* X X 3 1 3 2-4 X X X X X X X X * - Cleat (65404) accessory required see page 4 ** - Cleat (65406) accessory required see page 4 2/6/07 2:37:29 PM Circuit Breaker Lockout Cross Reference Guide Standard Breaker Lockouts Circuit Breaker Manufacturer Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Wylex Zinsco Zinsco Breaker Type JDB KA KB LA LB LBB LH MA MC MCC MCPO NB P PA QBHW QC QC QCHQ QHCW QHCX QHPW QPHW Quicklag P RE RH WPHX WRS40/2 HQB QB # of Poles EZ Panel Loc™ Mini Circuit Breaker Lockouts 120V Snap On (w/ hole) 120/277V Clamp On (no hole) 480/600V Clamp On (no hole) Oversize 480/600V Universal Multi-pole (tie bar) Snap On (SQD QO) Clamp On (Universal) Pin Out Standard Pin In Standard Pin Out Wide Multi-pole w/ Tie Bar 65387 65396 65397 65329 66321 51252 51254 90844 90847 90850 90853 3 3 X X** X X** X X X X** X** X** 3 3 2-3 2-3 2-3 3 X* X X 3 3 1 1 3 1 1 1 1 1 3 1 2 3 1 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X The Ultimate Lockout Lock! The Brady Safety Padlock complies with all OSHA requirements and is a safer alternative to metal locks for lockout applications. The body is nonconductive, while the unique key cylinder prevents electricity from traveling from the shackle to the key, further protecting workers from shock. The Brady Safety Padlock also delivers superior corrosion resistance. Third-party tests confirm that Brady outperforms the leading competitor when subjected to repeated salt water sprays. • • • • • • • • • • Compact and lightweight One-piece “seamless” body construction for rugged durability Special 6-pin cylinder resists tampering and offers more unique key cuts Key-retaining safety feature prevents key from being removed until shackle is securely closed. Ribbed sides for secure gripping, even when wearing gloves “Danger” and “Property Of” labels provided in English, Spanish and French Locks come keyed different or in keyed-alike sets. Custom keying and charting also available Lock bodies can be custom laser engraved upon request. Available in 8 high-visibility colors Brady Safety Padlocks Sold individually and in 6-packs Color 1 Padlock/Package Product Specifications • • • • • • Fiberglass reinforced nylon body for extra impact resistance Triple-coated hardened steel shackle resists corrosion Reserved paracentric keyway provides optimal security Service temperature: 0° - 250° F (-20° – 120° C) Lock body dimensions: 13/4”H x 11/2”W x 4/5”D Shackle clearance: 11/2”; shackle diameter: 1/4” Red Blue Green Yellow Orange Black Brown Purple Catalog No. 99552 99556 99564 99570 99576 99580 103033 104919 6 Padlocks/Package Catalog No. 51339 51344 51345 51346 51347 51353 101956 104916 Brady Keyed Alike Safety Padlocks Keyed Alike Safety Padlock Sets When keyed alike, all locks in a set can be opened with the same key. This option is beneficial when multiple locks are assigned to a single employee. Part numbers are to the right 3 Padlock/Package Catalog No. 105886 105887 105889 105888 6 Padlocks/Package Catalog No. 105890 105891 105893 105892 Color Red Blue Green Yellow Don’t see your circuit breaker? Call us at 888-272-3946 CircBreakerxref FINAL v2.indd 15 www.bradyid.com/lockout Features & Benefits 15 2/6/07 2:37:30 PM Specify Brady... The world leader in Lockout / Tagout Brady offers the most extensive line of products to make your hazardous energy control program more safe and efficient. Not only do our innovative products and services ensure OSHA compliance, they also reduce costs by avoiding accidents and injuries, and increase productivity by safely speeding up lockout procedures and reducing downtime. Brady offers a variety of cost effective solutions for enhancing all aspects of your energy control program, including: n n n n n Documented Procedures and Policies Energy Source Identification Employee Training Lockout Devices Lockout Kits and Stations For more information about our full line of Lockout / Tagout products and services Contact your local Brady Distributor, or visit www.bradyid.com/lockout Brady Worldwide, Inc. 6555 W. Good Hope Road Milwaukee, WI 53223 1-888-272-3946 www.bradyid.com Brady Canada 355 Apple Creek Blvd. Markham, ON L3R 9X7 1-800-262-6179 www.bradycanada.com WWW.BRAD YID .CO M/LOC KOUT Y483783 cover.indd 2 AN ISO-9001 REGISTERED FIRM © 2006 BRADY Corporation. All Rights Reserved. Specifications subject to change without notice. 2/1/07 2:45:08 PM