www.osram-americas.com/ENCELIUM ENCELIUM® Wall Switch Occupancy Sensors Key Features & Benefits Modern occupancy sensors use digital technology to ensure that the occupants in a room have light when they are present and that lighting energy is saved when the room is unoccupied. Depending on the application, either single technology (SSP) or multitechnology (SSM) sensors are appropriate to maximize occupant and energy manager satisfaction. ENCELIUM Wall Switch Occupancy Sensors are used to provide automatic lighting control for energy savings and convenience in a variety of commercial applications. The manual override switch, which can be used to keep lights OFF while an area is occupied, is ideal for conference rooms, classrooms and other areas used for video or presentation viewing. Application Information Applications —— Classrooms —— Conference rooms —— Lounges —— Private and Executive offices LMS076R2 3-14 —— Restrooms (SSM model) —— Retrofit (SSM model) —— Storage areas (SSM model) —— Training areas (SSM model) —— State of the Art Sensors: Passive —— Line Voltage Operation: Universal Range 120-277 Vac Infra-Red (PIR) sensors and MultiTechnology sensors provide a wide —— Integrated Daylight Hold-OFF variety of space coverage while Light Sensor: Avoid wasting providing options for fine motion energy when there is enough sensitivity. (see Ordering natural light. Information table.) —— Auto-Adapting Mode: Sensor’s —— Simple Installation: Fits in a digital system continually analyzes standard wall box and replaces and adjusts the sensitivity and a single-pole wall switch. time delay. —— Adjustable Horizontal Field of —— Walk-Through Mode: Provides View (PIR): May be adjusted increased energy savings by between 180˚ and 32˚ (SSM model) decreasing the time delay to and between 180˚ and 60˚ (SSP 2.5 minutes when someone model) of arc by using integral momentarily walks through the blinders located on either side of monitored space. the lens. —— Adaptive Learning with Local Protected Memory: Sensor self-calibrates to optimize performance and retains settings during power interruptions. Ordering Information Item Ordering NumberDescription 45372SSP-LNV 45373 SSM-LNV Sensing Technology(ies) PIR PIR + U/S Sensing Angle (degrees) 180 180 Coverage (ft2) 2100 2400 Adaptive Learning Scenarios Real-World Scenario Adaptive Learning Reaction An installer accidentally leaves the sensor in the 6 sec. timer test mode and the lights may go OFF or ON every 6 sec. The sensor automatically resets the timer to 10 min. after 15 min. of test mode. The sensor detects movement in a nearby corridor or hallway and the room lights turn ON. After an initial movement is sensed, if another movement is not sensed within the timer setting then the delayed OFF time setting is automatically reduced. The sensor does not detect movement because an occupant sits virtually motionless at a desk and the lights turn OFF If motion is sensed within a short period after the lights go OFF, then the current delayed OFF-time setting is increased. Sensor Specifications (SSM and SSP Models) Sensor Electrical Specifications: —— Input Voltage: 120-277 Vac —— Power Consumption: SSM Model: 110mW @ 120V, 340mW @ 277V SSP Model: 100mW @ 120V, 250mW @ 277V —— Operational Frequencies: 60Hz —— Ultrasonic Operating Frequency: 40kHz (SSM model) —— Load Rating: Incandescent/Tungsten: 800W @ 120V Fluorescent: 1200VA @ 120V 2700VA @ 277V Motor: 1/4 HP @ 120V —— Wire Designation: Line – Black Load – Blue Ground – Green Environmental Specifications: —— Operating Temperature Range: 32°F to 104°F (0°C to 40°C) —— Storage Temperature Range: 14°F to 185°F (-10°C to 85°C) —— Relative Humidity: 20% to 90% non-condensing Physical Specifications: —— Size: 4.06" H x 1.75" W x 1.85" D (103.2mm x 44.4mm x 47.2mm) —— Color: White —— Housing: Rugged, high-impact, flame class rating, UV inhibitors Other Specifications: —— Listings: ETL/cETL Listed, CSA (SSM model) UL Listed/CSA Certified (SSP model) CEC Title 24 Compliant, FCC Compliant Adjustment Options for Multi-Technology Wall Switch Occupancy Sensors The Wall Switch Occupancy Sensor is preset to deliver optimum performance in a wide variety of commercial applications. There are optional adjustments for sensitivity, ambient light override, delayed-OFF time, and field-of-view. These adjustments will customize the performance to meet the needs of a specific installation. To avoid tampering, all adjustments can only be accessed by removing the control panel cover. A small flat-head screwdriver can be used to adjust the control knobs, and the field-of-view blinders are finger-tip operated. Controls are labeled as follows: Blinders – Integral sliding blinders on each side of the lens may be used to restrict the 180° field of view down to 32°. This will prevent unwanted detection in areas such as hallways. Time – The delayed OFF time is preset at 30 minutes in the Auto Adapting mode. A choice of four delayed-OFF time settings are available: 30-seconds (for walking test purposes only), 10, 20, and 30 minutes for fixed time and auto adapting. The LED will flash when the adjusting knob is set to the indicated time value. Range (PIR) – Adjusting the range allows the unit to ignore motion at the far end of its range and avoid unnecessarily switching lights ON. The range can be adjusted from 100% to 35% of the total coverage area. Sensitivity (SSM Model U/S) – Users can adjust internal ultrasonic operation to maximize detection of motion while minimizing the effects of environmental noise (electrical noise, air currents, temperature changes, etc.). Adjustment is made by pushing the ON-OFF button in a prescribed sequence to Low-Medium-High sensitivity (see installation sheet). Light – The sensor is factory preset without any ambient light override in effect. This means the unit will switch lights ON when it detects occupancy, regardless of the amount of natural sunlight present. To maximize energy savings in some installations, the ambient light override feature will prevent the unit from switching lights ON when there is ample natural sunlight, regardless of occupancy. This adjustment should be made when the ambient light is at the level where no artificial light is needed. Installation The Wall Switch Occupancy Sensors are preset to deliver optimum performance in a wide variety of applications without requiring any adjustments during installation. Exclusive self-adjusting operating features will automatically compensate for real-time occupancy patterns to provide maximum convenience and energy savings. The unit may replace a singlepole wall switch mounted in a standard wall box. The unit does not require a neutral for installation. The unit’s integral blinders may be used to restrict the field of view to prevent unwanted detection of hallway traffic. It should be positioned at least 6 feet away from HVAC registers. Note that whenever the unit is powered up, it will take approximately 1 minute to begin normal operation. Wiring Diagrams Blue Blue Hot (Black) Black Blue Black Black Line 120-230-277VAC, 50/60Hz Load Black Line 120-230-277VAC, 60Hz Load Green Ground White Green Ground White Green Ground Black Hot (Black) Neutral (White) Neutral (White) Note: Ground must be connected Note: Ground must be connected Single Location Control Multi-Location Control Field-of-View TOP VIEW TOP VIEW 30 30 20 15 0 0 15 20 30 5 4 0 30 SIDE VIEW 0 20 40 5 4 0 SIDE VIEW 0 15 Major Motion, PIR Major Motion, U/S Major Motion, PIR Major Motion, PIR Major Motion, U/S Minor Motion, PIR SSM-LNV, 2,400 sq. ft. SSP-LNV, 2,100 sq. ft. 40 Dimensions 1.750" (44.45mm) .497" (12.62mm) 1.850" (49.99mm) 1.750" (44.45mm) .497" (12.62mm) 1.353" (34.37mm) 1.850" (49.99mm) 1.353" (34.37mm) Ultrasonic Ports for SSM model only 4.060" (103.12mm) 2.648" (67.26mm) 4.060" (103.12mm) Warranty ENCELIUM ® Occupancy Sensors and Power Packs are covered by the ENCELIUM Energy Management System Limited warranty. For the full text of the limited warranty, or to download the warranty registration form, refer to the limited warranty which is available in the Tools & Resources section of www.osram-americas.com. Americas Headquarters 100 Endicott Street Danvers, MA 01923 USA Phone1-800-LIGHTBULB www.osram-americas.com OSRAM is a registered trademark of OSRAM GmbH. ENCELIUM is a registered trademark. Specifications subject to change without notice. © 2014 OSRAM 2.648" (67.26mm)