ENCELIUM® Wall Switch Occupancy Sensors

advertisement
www.osram-americas.com/ENCELIUM
ENCELIUM® Wall Switch Occupancy Sensors
Key Features & Benefits
Modern occupancy sensors use digital technology to ensure that the
occupants in a room have light when they are present and that lighting
energy is saved when the room is unoccupied.
Depending on the application, either single technology (SSP) or multitechnology (SSM) sensors are appropriate to maximize occupant and
energy manager satisfaction.
ENCELIUM Wall Switch Occupancy Sensors are used to provide
automatic lighting control for energy savings and convenience in a
variety of commercial applications. The manual override switch, which
can be used to keep lights OFF while an area is occupied, is ideal for
conference rooms, classrooms and other areas used for video or
presentation viewing.
Application Information
Applications
—— Classrooms
—— Conference rooms
—— Lounges
—— Private and Executive offices
LMS076R2 3-14
—— Restrooms (SSM model)
—— Retrofit (SSM model)
—— Storage areas (SSM model)
—— Training areas (SSM model)
—— State of the Art Sensors: Passive —— Line Voltage Operation: Universal
Range 120-277 Vac
Infra-Red (PIR) sensors and MultiTechnology sensors provide a wide —— Integrated Daylight Hold-OFF
variety of space coverage while
Light Sensor: Avoid wasting
providing options for fine motion
energy when there is enough
sensitivity. (see Ordering
natural light.
Information table.)
—— Auto-Adapting Mode: Sensor’s
—— Simple Installation: Fits in a
digital system continually analyzes
standard wall box and replaces
and adjusts the sensitivity and
a single-pole wall switch.
time delay.
—— Adjustable Horizontal Field of
—— Walk-Through Mode: Provides
View (PIR): May be adjusted
increased energy savings by
between 180˚ and 32˚ (SSM model)
decreasing the time delay to
and between 180˚ and 60˚ (SSP
2.5 minutes when someone
model) of arc by using integral
momentarily walks through the
blinders located on either side of
monitored space.
the lens.
—— Adaptive Learning with Local
Protected Memory: Sensor
self-calibrates to optimize
performance and retains settings
during power interruptions.
Ordering Information
Item Ordering NumberDescription
45372SSP-LNV
45373
SSM-LNV
Sensing
Technology(ies)
PIR
PIR + U/S
Sensing Angle
(degrees)
180
180
Coverage
(ft2)
2100
2400
Adaptive Learning Scenarios
Real-World Scenario
Adaptive Learning Reaction
An installer accidentally leaves the sensor in the 6 sec. timer test mode and
the lights may go OFF or ON every 6 sec.
The sensor automatically resets the timer to 10 min. after 15 min. of test mode.
The sensor detects movement in a nearby corridor or hallway and the room
lights turn ON.
After an initial movement is sensed, if another movement is not sensed within
the timer setting then the delayed OFF time setting is automatically reduced.
The sensor does not detect movement because an occupant sits virtually
motionless at a desk and the lights turn OFF
If motion is sensed within a short period after the lights go OFF, then the
current delayed OFF-time setting is increased.
Sensor Specifications (SSM and SSP Models)
Sensor Electrical Specifications:
—— Input Voltage: 120-277 Vac
—— Power Consumption:
SSM Model: 110mW @ 120V, 340mW @ 277V
SSP Model: 100mW @ 120V, 250mW @ 277V
—— Operational Frequencies: 60Hz
—— Ultrasonic Operating Frequency: 40kHz (SSM model)
—— Load Rating:
Incandescent/Tungsten: 800W @ 120V
Fluorescent: 1200VA @ 120V
2700VA @ 277V
Motor: 1/4 HP @ 120V
—— Wire Designation:
Line – Black
Load – Blue
Ground – Green
Environmental Specifications:
—— Operating Temperature Range: 32°F to 104°F (0°C to 40°C)
—— Storage Temperature Range: 14°F to 185°F (-10°C to 85°C)
—— Relative Humidity: 20% to 90% non-condensing
Physical Specifications:
—— Size: 4.06" H x 1.75" W x 1.85" D (103.2mm x 44.4mm x 47.2mm)
—— Color: White
—— Housing: Rugged, high-impact, flame class rating, UV inhibitors
Other Specifications:
—— Listings: ETL/cETL Listed, CSA (SSM model)
UL Listed/CSA Certified (SSP model)
CEC Title 24 Compliant, FCC Compliant
Adjustment Options for Multi-Technology Wall Switch Occupancy Sensors
The Wall Switch Occupancy Sensor is preset to deliver optimum performance
in a wide variety of commercial applications. There are optional adjustments
for sensitivity, ambient light override, delayed-OFF time, and field-of-view.
These adjustments will customize the performance to meet the needs of a
specific installation. To avoid tampering, all adjustments can only be
accessed by removing the control panel cover. A small flat-head screwdriver
can be used to adjust the control knobs, and the field-of-view blinders are
finger-tip operated. Controls are labeled as follows:
Blinders – Integral sliding blinders on each side of the lens may be used
to restrict the 180° field of view down to 32°. This will prevent unwanted
detection in areas such as hallways.
Time – The delayed OFF time is preset at 30 minutes in the Auto Adapting
mode. A choice of four delayed-OFF time settings are available: 30-seconds
(for walking test purposes only), 10, 20, and 30 minutes for fixed time and
auto adapting. The LED will flash when the adjusting knob is set to the
indicated time value.
Range (PIR) – Adjusting the range allows the unit to ignore motion at the far
end of its range and avoid unnecessarily switching lights ON. The range can
be adjusted from 100% to 35% of the total coverage area.
Sensitivity (SSM Model U/S) – Users can adjust internal ultrasonic
operation to maximize detection of motion while minimizing the effects of
environmental noise (electrical noise, air currents, temperature changes,
etc.). Adjustment is made by pushing the ON-OFF button in a prescribed
sequence to Low-Medium-High sensitivity (see installation sheet).
Light – The sensor is factory preset without any ambient light override in
effect. This means the unit will switch lights ON when it detects occupancy,
regardless of the amount of natural sunlight present. To maximize energy
savings in some installations, the ambient light override feature will prevent
the unit from switching lights ON when there is ample natural sunlight,
regardless of occupancy. This adjustment should be made when the ambient
light is at the level where no artificial light is needed.
Installation
The Wall Switch Occupancy Sensors are preset to deliver optimum
performance in a wide variety of applications without requiring any
adjustments during installation. Exclusive self-adjusting operating features
will automatically compensate for real-time occupancy patterns to provide
maximum convenience and energy savings. The unit may replace a singlepole wall switch mounted in a standard wall box. The unit does not require
a neutral for installation. The unit’s integral blinders may be used to restrict
the field of view to prevent unwanted detection of hallway traffic. It should be
positioned at least 6 feet away from HVAC registers. Note that whenever the
unit is powered up, it will take approximately 1 minute to begin normal
operation.
Wiring Diagrams
Blue
Blue
Hot (Black)
Black
Blue
Black
Black
Line
120-230-277VAC,
50/60Hz
Load
Black
Line
120-230-277VAC,
60Hz
Load
Green
Ground
White
Green
Ground
White
Green
Ground
Black
Hot (Black)
Neutral (White)
Neutral (White)
Note: Ground must be connected
Note: Ground must be connected
Single Location Control
Multi-Location Control
Field-of-View
TOP VIEW
TOP VIEW
30
30
20
15
0
0
15
20
30
5
4
0
30
SIDE VIEW
0
20
40
5
4
0
SIDE VIEW
0
15
Major Motion, PIR
Major Motion, U/S
Major Motion, PIR
Major Motion, PIR
Major Motion, U/S
Minor Motion, PIR
SSM-LNV, 2,400 sq. ft.
SSP-LNV, 2,100 sq. ft.
40
Dimensions
1.750"
(44.45mm)
.497"
(12.62mm)
1.850"
(49.99mm)
1.750"
(44.45mm)
.497"
(12.62mm)
1.353"
(34.37mm)
1.850"
(49.99mm)
1.353"
(34.37mm)
Ultrasonic Ports for
SSM model only
4.060"
(103.12mm)
2.648"
(67.26mm)
4.060"
(103.12mm)
Warranty
ENCELIUM ® Occupancy Sensors and Power Packs are covered by the ENCELIUM Energy Management System Limited warranty. For the full text of the limited warranty,
or to download the warranty registration form, refer to the limited warranty which is available in the Tools & Resources section of www.osram-americas.com.
Americas Headquarters
100 Endicott Street
Danvers, MA 01923 USA
Phone1-800-LIGHTBULB
www.osram-americas.com
OSRAM is a registered trademark of OSRAM GmbH.
ENCELIUM is a registered trademark.
Specifications subject to change without notice.
© 2014 OSRAM
2.648"
(67.26mm)
Download