American Electric Lighting a division of Acuity Lighting Group, Inc. Newark, OH INSTALLATION & MAINTENANCE INSTRUCTIONS ACP COMPACT FLOODLIGHT ! WARNING ENSURE UNIT IS PROPERLY GROUNDED AND DISCONNECT POWER DURING INSTALLATION AND BEFORE SERVICING TO AVOID THE RISK OF SEVERE OR FATAL ELECTRICAL SHOCK READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION ! WARNING RISK OF FIRE. PRODUCT FOR OUTDOOR INSTALLATION AND USE ONLY. ! CAUTION TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. FOR CODE INTERPRETATION, CONSULT LOCAL CODE AUTHORITY INSTALLATION YOKE MOUNT: THE YOKE HAS 3 MOUNTING HOLES, ONE FOR A 3/4" BOLT AND TWO FOR 3/8" BOLTS. MOUNTING ADAPTORS ARE AVAILABLE TO ALLOW FOR HORIZONTAL ADJUSTMENT ON POLE TOPS, CROSS ARMS, ETC. HORIZONTAL ADJUSTMENT MUST BE DETERMINED BEFORE MOUNTING THE YOKE TO THE CROSSARM IF THE ACP FLOOD IS BEING MOUNTED DIRECTLY TO A CROSSARM WITHOUT THOSE OPTIONAL FITTERS. CLAMPING BOLTS (2) TENON MOUNT: THE COMPACT FLOOD WITH OPTIONAL TENON MOUNT CAN BE MOUNTED TO A 2" OR 2 1/2" PIPE TENON. TIGHTEN ALL FOUR SET SCREWS EQUALLY TO A MAXIMUM OF 350 INCH LBS., THEN TIGHTEN EACH LOCK NUT TO A MAXIMUM OF 350 INCH LBS. TO SECURELY ATTACH FIXTURE TO TENON TOP. WIRING COMPARTMENT ADJUSTMENT: POWER CORD ENTRY YOKE MOUNT: INDEX MARKS ARE INDICATED ON EACH SIDE OF YOKE FOR DETERMINING DESIRED MOUNTING ANGLES. THE BOLTS ON EACH SIDE OF YOKE NEED TO BE LOOSENED, VERTICAL ADJUSTMENT MADE AND THEN BOTH BOLTS RETIGHTENED TO A MAXIMUM OF 400 INCH LBS. REMOVABLE PLUG SCREWS (3) TENON MOUNT: THE SET SCREWS AND LOCK NUTS SHOULD BE LOOSENED AND HORIZONTAL ADJUSTMENT MADE. SET SCREWS SHOULD THEN BE RETIGHTENED AND LOCK NUTS RETIGHTENED. INDEX MARKS ARE INDICATED ON TENON FOR DETERMINING DESIRED ANGLE. LOOSEN BOLT IN CENTER OF TENON MOUNTED ACP COMPACT FLOOD TO DESIRED ANGLE AND RETIGHTEN BOLT TO SECURE TENON MOUNT.TIGHTEN BOLT TO A MAXIMUM OF 400 INCH ILBS. BREATHING HOLES CLOSURE SCREWS (2) THIS UNIT HAS BEEN DESIGNED WITH THREE BREATHING HOLES. TWO HOLES IN THE WIRING COMPARTMENT AREA AND 1 HOLES IN THE BEZEL. ALL HOLES ARE PLUGGED WITH A SCREW. ONLY IF THE UNIT IS YOKE MOUNT AND HAS NO PHOTOCONTROL RECEPTACLE MUST ANY ACTION BE TAKEN. THE SCREW IN THE BEZEL IS TO BE REMOVED ONLY IF THE UNIT IS FACING DOWN. ONE OF THE TWO SCREWS IN THE WIRING COMPARTMENT IS TO BE REMOVED ONLY IF THE UNIT IS FACING UP. CHOOSE THE SCREW THAT IS NOT HOLDING DOWN THE CAPACITOR BRACKET. 2 2 1 1 DRAWING NO. A71218 REV B (FRONT) ©2007 ACUITY LIGHTING GROUP, INC. Dia /32 25 ia 6D 7/1 YOKE MOUNTING HOLES PART NUMBER 057-70-71218 YOKE MOUNT American Electric Lighting a division of Acuity Lighting Group, Inc. Newark, OH WIRING YOKE MOUNT: OPTIONAL FACTORY PRE-WIRED FLOODS ARE FURNISHED WITH 3 FEET OF FLEXIBLE CABLE READY FOR CONNECTION TO SUPPLY. FOR STANDARD UNITS THAT ARE NOT PRE-WIRED, OPEN BEZEL BY LOOSENING THE 2 CLOSURE SCREWS OR LATCHES LOCATED AT THE TOP OF FLOOD. LIFT THE SHIELD TO EXPOSE THE WIRING COMPARTMENT. REMOVE THE COMPRESSION FITTING AND GROMMET, FEED CABLE THROUGH THE WIRE ENTRY HOLE. SLIP THE GROMMET AND COMPRESSION FITTING OVER THE CABLE AND REASSEMBLE TO HOUSING. USING THE WIRING DIAGRAM AS A GUIDE, MAKE CONNECTIONS TO THE TERMINAL BLOCK. ATTACH THE GREEN GROUND WIRE TO THE GROUNDING BOSS WITH THE GREEN GROUND SCREW PROVIDED. MULTI-VOLT BALLAST ARE FACTORY WIRED FOR 120V OPERATION UNLESS OTHERWISE SPECIFIED. CABLE SHOULD BE #16 AWG MINIMUM, TYPE SJ, SO, OR SJT-WA, SUITABLE FOR 105C OPERATION HINGE SCREW TENON MOUNT: OPEN ACCESS DOOR ON TENON MOUNT, FEED SUPPLY WIRES THROUGH BOTTOM OF TENON MOUNT AND OUT ACCESS DOOR. SLIP TENON MOUNT OVER POLE TENON AND CONNECT SUPPLY LEADS TO FIXTURE WIRES. PUSH LEADS BACK INTO WIRING COMPARTMENT OF TENON MOUNT AND REPLACE COVER. BEZEL REPLACEMENT TENON MOUNT OPEN THE BEZEL BY LOOSENING THE 2 SCREWS OR LATCHES. LOOSEN THE HINGE KEEPER SCREW AND SLIDE THE BEZEL OFF. ASSEMBLE THE REPLACEMENT BEZEL IN THE REVERSE MANNER. LAMP SERVICING OPEN THE BEZEL BY LOOSENING THE 2 SCREWS OR LATCHES. ALLOW IT TO HANG FREELY ON IT’S HINGE. THE LAMP SHOULD THEN BE UNSCREWED COUNTER CLOCKWISE UNTIL FREE. THE LAMP CAN THEN BE REPLACED BY REVERSING THE PROCEDURE. ENSURE WHEN RELAMPING TO USE THE CORRECT LAMP TYPE AND VALUE. RELAMP IN ACCORDANCE WITH THE BALLAST EMPLOYED FOR A MAXIMUM OF 400W HPS OR 400W MH. IF LAMP IS MARKED Hg IT CONTAINS MERCURY. FOLLOW DISPOSAL LAWS. SEE WWW.LAMPRECYCLE.ORG ACCESS DOOR SET SCREWS (4) DRAWING NO. A71218 REV B (REAR) ©2007 ACUITY LIGHTING GROUP, INC. PART NUMBER 057-70-71218 REV DATE DESCRIPTION ECN BY -A B 25-JUL-2005 28-FEB-2007 6-NOV-2007 NEW RELEASE R034503 MAH DAH ADD TEXT FOR PEC AND RELAMPING ADD LAMP HG NOTE R040067 R042055 MAH DAH GEW JRC PART NUMBER. 057-70-71218 DESCRIPTION APP DWG NUMBER INSTALLATION INSTRUCTIONS ACP COMPACT FLOOD A71218 SHT 3 OF 3