louis poulsen Instruction No.: 1440331000 Munkegaard Mega Design:Arne Jacobsen 120/277V T-5 2GX13 18 Lbs Wipe off dust with a dry, soft cloth. Remove greasy spots with a mild detergent. Wring the cloth thoroughly before use. Never use detergents containing alcohol. All installation is subject to local code and jurisdiction. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Damp Location Grounded Headoffice Denmark Louis Poulsen Lighting A/S. Tel: +45 33 14 14 14 Fax: +45 33 14 60 62 www.louis-poulsen.dk Export Division Louis Poulsen Lighting A/S. Tel: +45 33 31 11 66 Fax: +45 33 29 86 46 France Louis Poulsen & Cie Tel: +33 1 49 59 68 68 Fax: +33 1 49 59 68 69 www.louis-poulsen.fr Holland Louis Poulsen B.V. Tel: +31 23 5650030 Fax: +31 23 5652284 www.louis-poulsen.nl Norway Louis Poulsen & Co. A/S Tel: +47 22 50 20 20 Fax: +47 22 52 47 05 www.louis-poulsen.no Switzerland Louis Poulsen AG Tel: +41 1 733 70 40 Fax: +41 1 733 70 50 www.louis-poulsen.ch Denmark Frontdesk Tel: +45 33 31 11 66 Fax: +45 33 29 86 45 Finland Louis Poulsen Oy Tel: +358 9 6226 760 Fax: +358 9 6226 7650 www.louispoulsen.fi Germany Louis Poulsen & Co. GmbH Tel: +49 2103 940 0 Fax: +49 2103 940 290 www.louis-poulsen.de Japan Louis Poulsen Japan KK Tel: +81 3 3586 5341 Fax: +81 3 3586 0478 Sweden Louis Poulsen & Co. AB Tel: +46 8 446 48 00 Fax: +46 8 446 48 28 www.louispoulsen.se United Kingdom Louis Poulsen UK Ltd. Tel: +44 1372 848 800 Fax: +44 1372 848 801 www.louis-poulsen.co.uk USA Louis Poulsen Lighting, Inc. Tel: +1 954-349-2525 Fax: +1 954-349-2550 www.louispoulsen.com SUPPORT THE HOUSING ON THE T-BAR OR JOISTS BY MEANS OF THE BRACKETS PROVIDED. ADJUST THE HEIGHT OF THE HOUSING AS NEEDED BY MOVING THE BRACKETS, SO THAT THE FIXTURE FLANGE IS FLUSH WITH THE CEILING. WARNING: RISK OF FIRE. DO NOT INSTALL INSULATION WITHIN 3 INCHES OF FIXTURE SIDES OF WIRING COMPARTMENT/OR ABOVE FIXTURE IN SUCH A MANNER TO ENTRAP HEAT. SECURE THE “L”-BRACKETS TO THE “T”-BAR OR JOIST TO PREVENT THE HOUSING FROM TURNING L. BRACKET BRING THE INSTALLATION WIRE INTO THE WIRING COMPARTMENT BY MEANS OF FLEXIBLE CONDUIT MAKE THE ELECTRICAL CONNECTIONS AS FOLLOWS: NOTE: MAKE SURE ALL WIRES ARE PUSHED INSIDE THE SPLICEBOX TO PREVENT ANY PINCHING OF WIRES OR ELECTRICAL SHORTS. FLEXIBLE CONDUIT WIRING COMPARTMENT N: NEUTRAL=WHITE G: GROUND=GREEN L: LINE=BLACK SECURE THE MOUNTING PAN TO THE HOUSING WITH TWIST AND LOCK METHOD. HOUSING MOUNTING PAN INSTALL THE LIGHT SOURCES SECURE THE GLASS FRAME BY FEEDING THE SUSPENSION CABLE THROUGH THE TRIM AND FASTEN THE OTHER END TO THE HOUSING. NOW THE GLASS CAN BE SUSPENDED BY THE CABLE DURING RELAMPING. WARNING - IF YOUR UNIT HAS EMPK, DO NOT MATE EMPK CONECTOR UNTILL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. MOUNT THE GLASS FRAME TO THE FIXTURE BY TURNING IT CLOCKWISE UNTIL IT STOPS