Stridel Canopy Instructions - Architectural Star Lighting

advertisement
WARNING!
Risk of Electrical Shock
Disconnect power from circuit
breaker or fuse before installing or
servicing any light fixture.
STRIDEL CANOPYTM DECO
INSTALLATION INSTRUCTIONS
New Installation
Notes:
IMPORTANT SAFETY INFORMATION
For Your Protection, Read Carefully
Warning: Risk of fire. Do not install
insulation within 3 inches of fixture sides or
wiring compartment, nor above fixture in such
a manner as to entrap heat.
Caution: Before relamping or replacing any
item “TURN OFF POWER”
1. Electric current can cause serious
injury unless handled properly. For safety
reasons please take note of the following:
• Turn off the supply power.
• Ground the fixture to prevent potential
electrical shock.
• Do not handle an energized fixture or
energize any fixture with wet hands, when
standing on a wet or damp surface, or in
water.
1. Make sure power is off. Building wires must be in compliance with
local electrical codes.
2. All electrical wiring must be made by a qualified licenced electrician.
3. Hanger bars are supplied by the factory and are adjustable up to 24˝
4. Fixture must be above ceiling line before closing in.
Installation
1. Cut hole in ceiling tile exactly a 8 3/4˝ making sure to center
hole in frame with the ceiling hole. The ceiling hole must not
cover the tamper proof hardware attached to the frame in any
way.(See Fig. 1)
2. Insert bar hanger supports to fixture brackets on housing. (See Fig. 2)
3. Remove proper knockouts from junction box and attach connectors.
4. Place fixture in ceiling. Tie hanger supports loosely to support
members of the ceiling grid. Fasten hanger bars to ceiling grid
permanently. (See Fig. 3)
Wiring
1. Attach conduit or flex to junction box. Make all splices.
2. Fixture must be grounded with green or grounding wire provided.
Installation of Reflector and Deco Ring
1. Attach PL socket box to reflector and push reflector up into the fixture.
2. Once the reflector is installed take Deco ring and rest the ring on the
ceiling line. Align the supplied Torx head tamper proof screws with the
pem nuts on the frame in kit and screw them untill tightened.
Ceiling Cutout Fig. 1
Tamper Proof
Pem Nut Feature x4
2. Safety information concerning lamps:
• Match wattage of fixture and lamp
exactly.
• Do not remove or insert lamp when power
is on.
• Do not scratch glass or subject lamp to
undue pressure as either
may cause lamp breakage.
• Protect operating lamp from sources of
moisture.
Hanger Supports Fig. 2
Bar Hanger
1 1/2˝ Channel
1/2˝ Angle
Hanger Options Fig. 3
Fastener Holes
Alignment Tab
Self Nailing Feature
T-Bar Grid Slot
21 Father Devalles Blvd. Suite 201 Fall River, MA 02723 P. 508.678.1900 F. 508.678.1960 www.astarlighting.com
Download