WARNING! Risk of Electrical Shock Disconnect power from circuit breaker or fuse before installing or servicing any light fixture. STRIDEL CANOPYTM DECO INSTALLATION INSTRUCTIONS New Installation Notes: IMPORTANT SAFETY INFORMATION For Your Protection, Read Carefully Warning: Risk of fire. Do not install insulation within 3 inches of fixture sides or wiring compartment, nor above fixture in such a manner as to entrap heat. Caution: Before relamping or replacing any item “TURN OFF POWER” 1. Electric current can cause serious injury unless handled properly. For safety reasons please take note of the following: • Turn off the supply power. • Ground the fixture to prevent potential electrical shock. • Do not handle an energized fixture or energize any fixture with wet hands, when standing on a wet or damp surface, or in water. 1. Make sure power is off. Building wires must be in compliance with local electrical codes. 2. All electrical wiring must be made by a qualified licenced electrician. 3. Hanger bars are supplied by the factory and are adjustable up to 24˝ 4. Fixture must be above ceiling line before closing in. Installation 1. Cut hole in ceiling tile exactly a 8 3/4˝ making sure to center hole in frame with the ceiling hole. The ceiling hole must not cover the tamper proof hardware attached to the frame in any way.(See Fig. 1) 2. Insert bar hanger supports to fixture brackets on housing. (See Fig. 2) 3. Remove proper knockouts from junction box and attach connectors. 4. Place fixture in ceiling. Tie hanger supports loosely to support members of the ceiling grid. Fasten hanger bars to ceiling grid permanently. (See Fig. 3) Wiring 1. Attach conduit or flex to junction box. Make all splices. 2. Fixture must be grounded with green or grounding wire provided. Installation of Reflector and Deco Ring 1. Attach PL socket box to reflector and push reflector up into the fixture. 2. Once the reflector is installed take Deco ring and rest the ring on the ceiling line. Align the supplied Torx head tamper proof screws with the pem nuts on the frame in kit and screw them untill tightened. Ceiling Cutout Fig. 1 Tamper Proof Pem Nut Feature x4 2. Safety information concerning lamps: • Match wattage of fixture and lamp exactly. • Do not remove or insert lamp when power is on. • Do not scratch glass or subject lamp to undue pressure as either may cause lamp breakage. • Protect operating lamp from sources of moisture. Hanger Supports Fig. 2 Bar Hanger 1 1/2˝ Channel 1/2˝ Angle Hanger Options Fig. 3 Fastener Holes Alignment Tab Self Nailing Feature T-Bar Grid Slot 21 Father Devalles Blvd. Suite 201 Fall River, MA 02723 P. 508.678.1900 F. 508.678.1960 www.astarlighting.com