DRPD-CAL | Portable Partial Discharge Calibrator The DRPD-CAL is the industry's most compact, rugged and portable calibration instrument used to generate Partial Discharge (PD) signals designed for use in industrial environments to calibrate systems and provide the utmost in user convenience. This partial discharge signal generator is extremely useful in performing system calibrations, the verification of PD sensing and monitoring equipment, measuring circuit integrity and charge according to IEC-60270. The DRPD-CAL generates multiple ranges of pulses which are conveniently spaced allowing for instrumentation synchronization and / or verification including timing calibration, time-of-arrival and differential schemes. Features & Benefits • A lightweight, compact industrial enclosed pulse generator that's easily transported anywhere to meet PD calibration needs. • Three output calibration channels with different injection charges 50Hz or 60Hz sine wave capable. • Conveniently spaced pulses, starting at zero crossing for 9- degrees of the sine wave. • Dual power input; Universal AC Input Power Adaptor/Charger or rechargeable NiMH batteries for use in remote or unpowered locations. Applications • Use as a portable (PD) pulse generator. • Used for calibration of partial discharge sensors, monitors and PD instrumentation. • Useful for measuring circuits in terms of apparent charge per IEC-60270 or other applicable PD standards. DRPD-CAL | Portable Partial Discharge Calibrator SPECIFICATIONS Operating Temperature Range: -20°C to +70°C / -4.0°F to 158°F User Interface: Two membrane pushbutton keys and 6 LEDs AC Input Power (AC Wall Adaptor) 100 – 240 VAC 47-63 Hz, 0.19A maximum. DC Input Power (Rechargeable Battery) Two NiMH rechargeable AA batteries. Recharge using the AC Wall Adapter. Automatic power shut down time 60 minutes Charging time (full charge) < 2.5 hours from 5.0VDC power supply Low battery detection < 2.1VDC (automatic power off) Operation time before recharge > 20 hours continuous External e or DC PD output / AC output < 500V peak / < 50V peak Number of output voltage ranges 3 Number of PD outputs (simultaneous) 3 PD output's charge (Range 1) 500pC, 1000pC, 1500pC PD output's charge (Range 2) 1650pC, 3300pC, 4950 pC PD output's charge (Range 3) 1500pC, 5000pC, 15000pC Output rise time (10/90% @ 10M Ohms) < 4.5nS Pulse width @ 50%, @ 50 Ohms < 20nS Pulse polarity Positive PD pulse repetition rate 1kHz @ 0-90 degrees of sine wave Sine wave output +/- 1V peak to peak (1kOhms minimum load) Sine wave frequency 50/60 Hz switchable DRPD-CAL – ORDERING INFORMATION Part # DRPD-CAL Dimensions W × D × H Description One DRPD-CAL Portable Partial Discharge Calibrator One Universal AC Wall Adapter One 15.25cm / 6.0” inter-connection cable of 18 gauge wire with one two-pin plastic 0.381cm / 0.15” connector and one pair of alligator clips, one black and one red Two Size AA, NiMH rechargeable batteries Two Two-pin, plastic 0.381cm / 0.15” connectors. 7.9 cm × 12.0 cm × 2.4 cm / 3.1" × 4.7" × 0.95" Contact your sales representative for application assistance or pricing. ©2015 Dynamic Ratings Specifications subject to change without notice. All rights reserved. DRPD-CAL Calibrator 151110