flip top fiberglass enclosures

advertisement
SUBMITTAL DATA SHEET
BULLETIN NO: ESFF804
(800) 736-0238
FAX: (904) 783-6965
http://www.hot-box.com
Email: hotboxsales@hps.hubbell.com
Models Nos:
HF011019022 through
HF026070045
- Fiberglass-
CONTINUOUS HINGE
AT REAR
HO
BOXT
FRONT LID
SEAM
CERTIFIED
SIDE LID
SEAM
Fiberglass color
is provided in
Standard Beige.
Other Colors
available at
modest upcharge.
HEATED “ORIGINAL”
FLIP TOP FIBERGLASS ENCLOSURES:
SPECIFICATION:
Old Hot Box
w/Heat
HB.75
HB1
HB1T
HB1.5
HB2
HB2T
HB2S
HB2ST
HB3N
HB3NS
HB3E
HB3ES
HB3000
HB4000
HB5000
SLAB OR
FOOTER
DRAINPORT
FLANGE
The enclosure, certified to ASSE 1060, shall be of min. 1/8" tk. thixotropic polyester resin reinforced with fiberglass strand. Molded exteriors will be a smooth, yacht
quality finish, protected w/UV inhibited isopthalic polyester gel coat. Non-molded
products will utilize an “industrial” exterior texture, with the same gel coated finish.
Insulation shall be min. 11/4" tk. (R8), uni-cellular, non-wicking, polyisocyanate foam.
Enclosure shall utilize a lockable flip top design, for maintenance access through lid
without removal of the entire unit. Molded product shall utilize an overlapping lid
seam design for weather proofing and vandal resistance. Drains shall be sized for full
port backflow discharge and designed for “one way” exit, inhibiting intrusion of debris and/or vermin. Enclosure shall be anchored to a concrete slab or GLASSPAD™
from within the enclosure w/steel anchors and require a single lock for security
purposes.
Heat will protect the piping and equipment from exterior temperatures to -30°F and be
thermostatically controlled. UL or ETL listed self-regulating cable(s) or wall mounted
air heater(s) will be sized to maintain the equipment at +40°F, in accordance with
N.F.P.A. 3-3.1.8 & 3-6.1.3.2. Heat source shall be mounted a minimum of 7" above
the slab unless it is UL or ETL certified and NEC approved for submersion. Power
source shall be installed inside the enclosure by others, protected with a ground fault
interrupting receptacle (GFI) or GFI circuit – ref. UL 943, N.E.M.A.3R.
Hot Box w/
Heat
HF011019022
HF013027023
HF013027035
HF021033025
HF013039028
HF013039036
HF013047028
HF013047036
HF026070045
HF026083045
HF026070055
HF026083055
HL035045035
HL044053044
HL052061052
HASP
Inside
Width
11
13
13
21
13
13
13
13
26
26
26
26
35
44
52
Inside
Length
19
27
27
33
39
39
47
47
70
83
70
83
45
53
61
Inside
Height
22
23
35
25
28
36
28
36
45
45
55
55
35
44
52
Heat
30W
60W
60W
60W
90W
90W
90W
90W
1000W
1500W
1500W
1500W
1000W
1000W
1500W
Models Nos:
HF013047036
HF026083045
HF026070055
HF026083055
Models Nos: HF035045035
through HF052061052
-FiberglassYACHT
QUALITY
EXTERIOR
HINGED
LID
DRAINPORT
OX
T B
HO
ADJUSTABLE
INTERNAL
ANCHOR (TYP.)
LOCKABLE
HASP AND
STAPLE
DRAINPORT
FLANGE
LOW PROFILE Series TM
Shipping
Weight
30#
40#
50#
60#
55#
65#
70#
100#
285#
365#
375#
395#
265#
290#
455#
Pad Size
GlassPad
Old GlassPad No.
28 x 20
36 x 22
36 x 22
44 x 32
50 x 24
50 x 24
58 x 24
58 x 24
82 x 38
95 x 38
82 x 38
95 x 38
57 x 47
65 x 56
74 x 64
GG019027005
GG021035005
GG021035005
GG030042005
GG021047005
GG021047005
N/A
N/A
N/A
N/A
N/A
N/A
GG046055005
GG055063005
GG063074005
GP.75
GP1
GP1
GP1.5
GP2
GP2
N/A
N/A
N/A
N/A
N/A
N/A
GP3000
GP4000
GP5000
MEMBERS OF:
Job Name
Contractor
Job Location
Approval
Engineer
Approval
Contractor’s P.O. No.
Date:
Representative
Date:
1
SUBMITTAL DATA SHEET
BULLETIN NO: ESFF804
(800) 736-0238
FAX: (904) 783-6965
http://www.hot-box.com
Email: hotboxsales@hps.hubbell.com
CERTIFIED
UNHEATED INSULATED
FLIP TOP FIBERGLASS ENCLOSURES:
SPECIFICATION:
The enclosure, certified to ASSE 1060, shall be of min. 1/8" tk. thixotropic
polyester resin reinforced with fiberglass strand. Molded exteriors will be a
smooth, yacht quality finish, protected w/UV inhibited isopthalic polyester gel
coat. Non-molded products will utilize an “industrial” exterior texture, with
the same gel coated finish. Insulation shall be min. 11/4" tk. (R8), uni-cellular,
non-wicking, polyisocyanate foam. Enclosure shall utilize a lockable flip top
design, for maintenance access through lid without removal of the entire unit.
Molded product shall utilize an overlapping lid seam design for weather proofing and vandal resistance. Drains shall be sized for full port backflow discharge
and designed for “one way” exit, inhibiting intrusion of debris and/or vermin.
Enclosure shall be anchored to a concrete slab or GLASSPAD™ from within
the enclosure w/steel anchors and require a single lock for security purposes.
NOTE: Please see page 1 for heated models.
Lok Box w/No
Heat
LF011019022
LF013027023
LF013027035
LF021033025
LF013039028
LF013039036
LF013047028
LF013047036
LF026070045
LF026083045
LF026070055
LF026083055
LL035045035
LL044053044
LL052061052
Old Lok Box w/
No Heat
LB.75
LB1
LB1T
LB1.5
LB2
LB2T
LB2S
LB2ST
LB3N
LB3NS
LB3E
LB3ES
LB3000
LB4000
LB5000
Inside
Width
11
13
13
21
13
13
13
13
26
26
26
26
35
44
52
Inside
Length
19
27
27
33
39
39
47
47
70
83
70
83
45
53
61
Inside
Height
22
23
35
25
28
36
28
36
45
45
55
55
35
44
52
Shipping
Weight
30#
40#
50#
60#
55#
65#
70#
100#
275#
355#
365#
385#
265#
290#
455#
Pad Size
GlassPad
Old GlassPad No.
28 x 20
36 x 22
36 x 22
44 x 32
50 x 24
50 x 24
58 x 24
58 x 24
82 x 38
95 x 38
82 x 38
95 x 38
57 x 47
65 x 56
74 x 64
GG019027005
GG021035005
GG021035005
GG030042005
GG021047005
GG021047005
N/A
N/A
N/A
N/A
N/A
N/A
GG046055005
GG055063005
GG063074005
GP.75
GP1
GP1
GP1.5
GP2
GP2
N/A
N/A
N/A
N/A
N/A
N/A
GP3000
GP4000
GP5000
MEMBERS OF:
2
Job Name
Contractor
Job Location
Approval
Engineer
Approval
Contractor’s P.O. No.
Date:
Representative
Date:
SUBMITTAL DATA SHEET
BULLETIN NO: ESFF804
(800) 736-0238
FAX: (904) 783-6965
http://www.hot-box.com
Email: hotboxsales@hps.hubbell.com
CERTIFIED
NO HEAT/NO INSULATION
FLIP TOP FIBERGLASS ENCLOSURES:
SPECIFICATION:
The enclosure, certified to ASSE 1060, shall be of min. 1/8" tk. thixotropic
polyester resin reinforced with fiberglass strand. Molded exteriors will be
a smooth, yacht quality finish, protected w/UV inhibited isopthalic polyester gel coat. Non-molded products will utilize an “industrial” exterior
texture, with the same gel coated finish. Enclosure shall utilize a lockable
flip top design, for maintenance access through lid without removal of the
entire unit. Molded product shall utilize an overlapping lid seam design for
weather proofing and vandal resistance. Drains shall be sized for full port
backflow discharge and designed for “one way” exit, inhibiting intrusion
of debris and/or vermin. Enclosure shall be anchored to a concrete slab or
GLASSPAD™ from within the enclosure w/steel anchors and require a
single lock for security purposes.
Valve Guard
No Insul.
VF011019022
VF013027023
VF013027035
VF021033025
VF013039028
VF013039036
VF013047028
VF026070045
VL035045035
VL044053044
VL052061052
Old Valve
Guard No Insul.
VG.75
VG1
VG1T
VG1.5
VG2
VG2T
VG2S
VG3N
VG3000
VG4000
VG5000
Inside
Width
13
15
15
23
15
15
15
29
38
47
55
Inside
Length
21
29
29
35
41
41
49
73
48
56
64
Inside
Height
23
24
36
26
29
37
29
46
36
45
53
Shipping
Weight
21#
31#
41#
46#
45#
56#
51#
270#
220#
270#
410#
Pad Size
GlassPad
Old GlassPad No.
28 x 20
36 x 22
36 x 22
44 x 32
50 x 24
50 x 24
58 x 24
82 x 38
57 x 47
65 x 56
74 x 64
GG019027005
GG021035005
GG021035005
GG030042005
GG021047005
GG021047005
N/A
N/A
GG046055005
GG055063005
GG063074005
GP.75
GP1
GP1
GP1.5
GP2
GP2
N/A
N/A
GP3000
GP4000
GP5000
MEMBERS OF:
Job Name
Contractor
Job Location
Approval
Engineer
Approval
Contractor’s P.O. No.
Date:
Representative
Date:
3
Download