INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LABC 91.2320 DOCUMENT NO. P/BC 2002-004 Previously Issued As: IB ST- 9 Effective: 1-20-00 Revised: 6-11-02 TYPE V SHEET ONE STORY CONSTRUCTION ONLY Type V construction is a classification of builidings by construction materials and methods. It is the least restrictive permitted by the Uniform Building Code and includes light, wood-frame construction. This sheet is for information and reference only and is not a substitute for accurate drawings prepared for each proposed construction project. LA City’s Type V-sheet is the same as the attached Type V sheet by LARUCP except hereby clarified with respect to note 5 on “Footings on Expansive Soils”. FOOTINGS ON EXPANSIVE SOILS Footing systems on expansive soil shall be constructed in a manner that will minimize damage to the structure from movement of the soil. 1. 2. 3. 4. 5. Depth of footings below the natural and finished grades shall not be less than 24 inches for exterior and 18 inches for interior footings. Exterior walls and interior bearing walls shall be supported on continuous footings. Footings shall be reinforced with four 1/2-inch diameter deformed reinforcing bars. Two bars shall be placed 4 inches from the bottom of the footing and two bars within 4 inches from the top of the footing. Concrete floor slabs on grade shall be placed on a 4-inch fill of coarse aggregate or on a moisture barrier membrane. The slabs shall be at least 3-1/2 inches thick and shall be reinforced with ½" diameter deformed reinforcing bars. Reinforcing bars shall be spaced at intervals not exceeding 16 inches each way. The soil below an interior concrete slab shall be saturated with a moisture to a depth of 18 inches prior to placing the concrete. As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, will provide reasonable accommodation to ensure equal access to its programs, services and activities. For efficient handling of information internally and in the internet, conversion to this new format of code related and administrative information bulletins including MGD and RGA that were previously issued will also allow flexibility and timely distribution of information to the public. Page 1 of 7 LOS ANGELES REGIONAL UNIFORM CODE PROGRAM TYPE V CONSTRUCTION- WOOD FRAME RESIDENTIAL BUILDINGS (CBC CHAPTER 23, DIV IV, SEC. 2320) ONE-STORY CONSTRUCTION TYPE V CONSTRUCTION IS A CLASSIFICATION OF BUILDINGS BY CONSTRUCTION MATERIALS AND METHODS. IT IS THE LEAST RESTRICTIVE PERMITTED BY THE UNIFORM BUILDING CODE AND INCLUDES LIGHT, WOOD-FRAME CONSTRUCTION. THIS SHEET IS FOR INFORMATION AND REFERENCE ONLY AND IS NOT A SUBSTITUTE FOR ACCURATE DRAWINGS PREPARED FOR EACH PROPOSED CONSTRUCTION PROJECT. E.N. 8d@6"oc EAVES EXTENDING CLOSER THAN 3'-0" TO PROPERTY LINE SHALL BE OF 1-HR CONSTRUCTION OR HEAVY-TIMBER (CBC 705) 1/2" CDX PLY W/ 8d @ 6"/ 6"/ 12" 2x ROOF RAFTERS @ 16"OC W/ R-30 BATT. INSUL. 1/2" CDX PLY SHEATHING W/ 8d @ 6"/ 6"/ 12" oc (COMMON NAILS) CEILING JOIST- LAP @ BEARING WALL 2x ROOF RAFTERS W/ R-30 BATT. INSUL. E.N. 8d@6"oc 2X CEILING JOISTS 2X SOLID BLOCKING W/ FRAMING ANCHOR EA. BLOCK FASCIA BOARD 2x SOLID BLOCKING 2X DOUBLE TOP PLATE 2X BLOCKING W/ FRAMING CLIPS @ EACH BLOCK 2X4 STUD WALL @ 16"oc (STUD GRADE) R-13 BATT INSUL. 1/2" STRUCT I PLY, OSB, OR STUCCO SHEAR PANEL (SEE PAGE #4) 5/8" T&G PLY W/ 10d @ 6"/ 6"/ 12" oc (COMMON NAILS) 2X P.T. SILL W/ 5/8"¯ X10" A.B. @ 6'oc, 2-1/2"x2-1/2"x1/4" PLATE WASHERS 2X RIM JOIST NOTES: A. STUCCO SHALL BE PROVIDED WITH A CORROSION-RESISTANT WEEP SCREED. WALL SECTION: SLAB-ON-GRADE CONSTRUCTION 12" 12" SQ. CONC. PAD POURED CONC. PIER W/ POST BASE 6" 12" 6" #4 BAR, TOP 3" MIN. 6" Min. NAT. GRADE 18" MIN. SEE NOTE #9 NAT. GRADE 12" MIN. 6" 4X GIRDER 4X4 P.T.POST W/ POST CAP 6" Min. 6" #4 BAR, TOP/ #4 BAR, BOTTOM (SEE NOTE #5 FOR EXPANSIVE SOILS) 2X P.T. SILL & ANCHOR BOLT 12" 12" 2X P.T. SILL W/ ANCHOR BOLTS AND PLATE WASHERS 6" 6" 12" SEE NOTE #5 #3 DOWELS @ 24"OC, EXTEND 36" INTO SLAB (FOR TWO POUR) R-19 BATT INSUL. AT JOIST SPLICE LAP 3" MIN. W/ 3-16d FOUNDATION DIMENSIONS SHOWN BASED ON NON-EXPANSIVE SOILS NAT. GRADE 3" CLEAR 4" CLEAR FOR EXPANSIVE SOIL 2X SOLID BLOCKING 2X BLOCKING @ 8'-0" OC FOR JOIST SPANS OVER 8'-0" 12" MIN. SEE NOTE 'A' 2X FLOOR JOISTS @ 16"oc 30" MIN. AT WALL WITH WINDOWS (CBC 1204) 3'-0" MIN. 6" 3-1/2" CONC. SLAB, 6X6-10/10 WWM (SEE NOTE #5 FOR EXPANSIVE SOILS) 2" SAND BED, 6 MIL VAPOR BARRIER 12" MAX. AT 3'-0" SETBACK (CBC 503.2.1) PROPERTY LINE 2X4 STUD WALL @ 16"oc (DF STUD GRADE- MINIMUM) R-13 BATT INSUL. 1/2" STRUCT I PLY, OSB, OR STUCCO SHEAR PANEL (SEE PAGE #4) 2X CEILING JOISTS @ 16" OC EXTERIOR BEARING WALL WHERE STUCCO IS APPLIED OVER PLY SHEATHINGPROVIDE 2-LAYERS GRADE 'D' PAPER UNDER LATH INTERIOR BEARING WALL 7'-6" MIN. (HABITABLE ROOMS) DOUBLE TOP PLATE #4 BAR, BOTTOM FOUNDATION DIMENSIONS WALL SECTION: RAISED FLOOR CONSTRUCTION SHOWN BASED ON NON-EXPANSIVE SOILS Notes: 1. Anchor bolts: 5/8"x10" embedded 7" and spaced 6'-0"oc with 2-1/2"x2-1/2"x1/4" plate washers, with minimum 2 anchor bolts per piece, located not more than12" or less than 7 bolt diameters from each end of the piece. 2. All foundation plates or sills and sleepers on a concrete or masonry slab, which is in direct contact with earth, and sills that rest on concrete or masonry foundations, shall be pressure treated wood. 3. Minimum Concrete Strength: 2500 psi. 4. Bearing walls and braced wall panels require continuous footings. 5. FOR EXPANSIVE SOIL: Refer to local jurisdiction requirements. 6. Where interior walls are shear wall panels, wall framing and sheathing shall extend to the roof sheathing. 7. Under floor areas shall be ventilated by approved mechanical means or by openings into the under-floor area walls. Such openings shall have a net area of not less than 1 square foot for each 150 square feet of under-floor area. Openings shall be located as close as possible to corners and provide cross ventilation. the openings shall be approximately equally distributed along the length of at least two sides. Corrosion resistant mesh w/ Minimum 1/4" openings. 8. Enclosed attics and enclosed rafter spaces shall have cross ventilation for each separate space . The net free ventilating area shall not be less than 1/150 of the area of the space ventilated. The openings may be 1/300 of the area provided 50% of the opening area is provided with ventilators in the upper portion at least 3' above the eave or cornice with the balance of the ventilators provided by eave or cornice vents. Provide baffles to prevent attic insulation from blocking eave vents. (CBC 1505.3) 9. For stem walls greater than 24" high: Refer to local jurisdiction requirements. Page 2 of 7 LARUCP/TYPEV1.2 12/2001 ALLOWABLE SPANS FOR DF #2 CEILING JOISTS (DF-LARCH) Dead Load: 5 psf/ Live Load: 10 psf ALLOWABLE SPANS FOR DF #2 ROOF RAFTERS (DF-LARCH) Light Dead Load (up to 15 psf)/ Max. Roofing Load: 6 psf (Asphalt Shingles) Live Load: 20 psf RAFTER SIZE SPACING ALLOWABLE SPAN JOIST SIZE SPACING 24" 16" 12" 24" 16" 12" 24" 16" 12" 2x4 24" 8'-8" 16" 10'-8" 12" 12'-4" 24" 11'-0" 2x8 16" 13'-5" 12" 15'-6" 24" 14'-0" 2x10 16" 17'-2" 12" 19'-10" 17'-0" 24" 2x12 20'-10" 16" 24'-1" 12" ALLOWABLE SPANS FOR DF #2 FLOOR JOISTS (DF-LARCH) Light Dead Load (up to 10 psf) Max. Flooring Load: 1.5 psf (Carpet orVinyl) Live Load: 40 psf JOIST SIZE SPACING ALLOWABLE SPAN 2x6 2x6 2x8 2x10 12" 24"* 8'-2" 5'-3" 5'-8" 16" 9'-9" 12" 10'-9" 24"* 10'-2" 2x8 6'-10" 7'-4" 16" 12'-7" 12" 14'-2" 24"* 12'-8" 2x10 16" 15'-0" 12" 17'-4" 24"* 14'-4" 2x12 16" 18'-0" 12" 20'-6" ALLOWABLE SPANS FOR PLYWOOD OR OSB FLOOR AND ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS-PERPENDICULAR TO SUPPORTS ROOF MAX. SPAN (IN) EDGE SUPPORT (2X BLOCKING) 26'-0" ALLOWABLE SPANS FOR DF #1 FLOOR GIRDERS (DF-LARCH) Max. Floor Dead Load: 15 psf Max. Tributary Width: 8'-0" SPAN GIRDER SIZE PARTITIONS NO PARTITIONS 2x6 SHEATHING GRADES SPAN RATING SPAN THICKNESS Floor/Roof Span 7/16, 1/2 24/0 ALLOWABLE SPAN 9'-10" 11'-3" 12'-5" 14'-9" 17'-8" 19'-6" 19'-0" 23'-4" 25'-8" NO EDGE SUPPORT FOR 1/2", MAX. SPAN +24" 24 20 ALLOWABLE SPANS FOR DF#1 HEADERS (DF-LARCH) Maximum span of tributary load: 20'-0" SPAN Up to 4'-0" BEAM SIZE 4x4 4x6 4'-1" to 6'-0" 4x6 4x8 6'-1" to 8'-0" 4x8 8'-1" to 10'-0" 4x10 10'-1" to 12'-0" 4x12* * 4x12 DF No.1 may be used over a 16'-0" garage door in one-story garages without ceilings or open patio or carport structures. NOTE: APPLIES TO PANELS 24" OR WIDER (UBC SEC. 2312) FLOOR LOADS (PSF) MAX. SPAN (IN) Panel edges with tongue and LIVE LOAD TOTAL LOAD groove joints or with blocking 30 40 16 50 40 24/16 7/16, 1/2 24 24 32/16 15/32, 1/2, 5/8 32 28 40 30 16 40/20 19/32, 5/8, 3/4, 7/8 40 32 40 30 20 48/24 23/32, 3/4, 7/8 48 36 45 35 24 NAILING SCHEDULE (CBC TABLE 23-II-B-1) JOIST TO SILL OR GIRDER, TOE NAIL BRIDGING TO JOIST, TOENAIL EACH END SOLE PLATE TO JOIST OR BLOCKING, TYPICAL FACE NAIL SOLE PLATE TO JOIST OR BLOCKING, AT BRACED WALL PANELS TOP PLATE TO STUD, END NAIL STUD TO SOLE PLATE DOUBLE STUDS, FACE NAIL DOUBLE TOP PLATES, TYPICAL FACE NAIL DOUBLE TOP PLATES, LAP SPLICE BLOCKING BETWEEN JOISTS OT RAFTERS TO TOP PLATE, TOENAIL RIM JOIST TO TOP PLATE, TOENAIL TOP PLATES, LAPS AND INTERSECTIONS, FACE NAIL CEILING JOISTS TO PLATE, TOENAIL CONTINUOUS HEADER TO STUD, TOENAIL CEILING JOISTS, LAPS OVER PARTITIONS, FACE NAIL CEILING JOISTS TO PARALLEL RAFTERS,FACE NAIL RAFTER TO PLATE, FACE NAIL BUILT-UP CORNER STUDS 2" PLANKS 3-8d 2-8d 16d @ 16"oc 3-16d per 16" 2-16d 4-8d, TOENAIL, OR 2-16d, END NAIL 16d @ 24" oc 16d @ 16" oc 8-16d 3-8d 8d @ 6" oc 2-16d 3-8d 4-8d 3-16d 3-16d 3-8d 16d @ 24" oc 2-16d @ EACH BEARING 3 LARUCP/TYPEV1.2 12/2001 1/3 'D' 2" MIN. 2" MIN. KING STUD- USE 2 KING STUDS WHEN SPAN IS 5'-11" OR MORE @ BEARING WALL 'D' D/4 MAX. STUDS TRIMMER- USE 2 TRIMMERS WHEN SPAN IS 8'-0" OR MORE @ BEARING WALL 'D' TOP PLATE 'D' D/6 MAX. D/6 MAX. HEADER- FULL STUD WIDTH BEARING NOTCHING & BORING FLOOR JOISTS (NOTCHING NOT PERMITTED IN MIDDLE 1/3 OF JOIST SPAN) D/4 MAX. 'D' D/3 MAX. 'D' 'D' 1/3 'D' 4:12 MIN. SLOPE W/ 1-LAYER TYPE 15 FELT 2:12 TO 4:12 MIN. SLOPE WITH SELF-SEALING OR HAND-SEALED COMP. SHINGLES W/ 2-LAYERS TYPE 15 FELT 2" MIN. 2" MIN. HEADER/ LINTEL (CBC 2320.11.6) D/6 MAX. D/6 MAX. 'D' MAX. SILL PLATE NOTCHING & BORING RAFTERS & CEILING JOISTS (NOTCHING NOT PERMITTED IN MIDDLE 1/3 OF RAFTER OR JOIST SPAN) ROOF SLOPE- COMP SHINGLES (CBC TABLE 15-B-1) 5/8" MIN. 25% MAX. ROOF SHEATHING 2X RIDGE BOARD2" LARGER THAN ROOF RAFTER 2X ROOF RAFTER 5/8" MIN. 40% MAX. 40% MAX. BEARING PARTITIONS 60% MAX. OR EACH BORED STUD DOUBLED. NOT PERMITTED IN MORE THAN 2 DOUBLE D STUDS NON-BEARING PARTITIONS NOTCHING & BORING: WALL STUDS (CBC 2320.11.9/ 2320.11.10), RAFTERS/CEILING JOISTS (CBC 2320.12.4) FLOOR JOISTS (CBC 2320.8.3) RIDGE (CBC 2320.12.3) 2X RIDGE BOARD 2X ROOF RAFTERS 12 2X PURLIN- SAME SIZE AS RAFTER 45° MIN. 2X4 BRACE @ 4'-0" OC 4X4 BRACE FOR LENGTHS OVER 6'-0" 2X SOLID BLOCKING 2X DOUBLE TOP PLATE 2X STUDS PURLINS (CBC 2320.12.7) 4 MIN. SLOPE 2X CEILING JOISTS INTERIOR BEARING WALL (FOR ROOF PITCH NOT LESS THAN 4 VERTICAL TO 12 HORIZONTAL) 25'-0" MAX. BETWEEN BEARING WALLS WITHOUT ENGINEERING 2X RIDGE BOARD 2X ROOF RAFTERS 12 4 MIN. SLOPE 1X RAFTER TIE @ 4'-0" OC 2X SOLID BLOCKING 2X DOUBLE TOP PLATE 2X STUDS RAFTER TIES (CBC 2320.12.6) 4 LARUCP/TYPEV1.1 12/2001 'H' FOR STUCCO BRACED WALL PANEL 96" MIN. 8'-0" MAX. FROM END OF WALL 25'-0" MAX 'H'/2 FOR WOOD BRACED WALL PANEL 48" MIN. SHEAR WALL OPTIONS: 1/2" STRUCT I PLY W/ 8d@ 6"/ 6"/ 12" OC OR OSB (COMMON NAILS) 7/8" STUCCO O/ WOVEN WIRE OR EXPANDED METAL LATH W/ NO.11 GA. NAILS, 1-1/2"X7/16" HEADS W/ 1/4" FURRING; APPLIES TO NAILING AT ALL STUDS, TOP & BOTTOM PLATES, & BLOCKING. NO PENETRATIONS PERMITTED IN BRACED WALL PANELS 'H' (HEIGHT OF PANEL) NOTES: SHEAR WALLS SHALL NOT BE OFFSET MORE THAN 4'-0" FROM EACH OTHER SHEAR PANEL TYPES SHALL NOT BE COMBINED IN THE SAME LINE OF RESISTANCE 25'-0" MAX. 25'-0" MAX. MINIMUM PANEL LENGTHS: PLYWOOD PANELS: NOT LESS THAN 25% OF BLDG. LENGTH STUCCO PANELS: NOT LESS THAN 50% OF BLDG. LENGTH 25'-0" MAX. BETWEEN BRACED WALL PANELS IN EACH DIRECTION STANDARD BRACED WALL PANELS (CBC 2320.11.3) 2'-8" MIN. 2'-8" MIN. CONT. DOUBLE TOP PLATE SOLID BLK.- ALL UNSUPPORTED PLYWOOD EDGES HEADER BOLT DEPTH 4X4 EACH SIDE OF PANEL 3" FOOTING #4 TOP & BOTTOM 1/4 OF PANEL WIDTH 10'-0" MAX. STRUCTURAL PANEL SHEATHING: 1/2" STRUCT I PLY OR OSB W/ 8d @ 6"/ 6"/ 12"(COMMON NAILS) P.T.D.F. SILL PLATE MIN. 2 ANCHOR BOLTS PER PANEL MAX. 12" & MIN. 5" FROM BREAK IN SILL PLATE 1/4 OF PANEL WIDTH HOLD DOWN EACH SIDE OF PANEL (1800# MIN. CAPACITY)THICKEN FOOTING AS REQUIRED FOR BOLT EMBEDMENT DEPTH (NO HOLD DOWN REQUIRED FOR PANELS EXCEEDING 48" IN WIDTH ALTERNATE BRACED WALL PANEL (CBC 2320.11.4 AS AMENDED BY LARUCP )1-STORY, 'U' OCCUPANCY ONLY (PRIVATE GARAGES, SHEDS, & AGRICULTURAL BUILDINGS) 5 LARUCP/TYPEV.1.1 12/2001 T&P VALVE PIPED TO EXTERIOR 3/4" MIN. PIPE. NO THREADS ALLOWED IN BOTTOM OF PIPING 4'-0" MIN. GARAGE FLOOR NOTE: NO GAS-FIRED WATER HEATER ALLOWED IN BEDROOMS, BATHROOMS, CLOTHES CLOSETS, OR ANY SPACE OPENING INTO A BEDROOM OR BATHROOM. WATER HEATERS ROOF SLOPE: FLAT TO <6:12 PROPERTY LINE RAISE 18" IN GARAGE 6" MIN/. 24" MAX. 4" BOTTOM 1/3 24" MIN. 12" MIN. FOR ROOFSLOPE: FLAT TO <6:12 PER MANF. RECOMMENDATION PER MANF. RECOMMENDATION TOP 1/3 EXTERIOR WALL SEISMIC STRAPS: TWO MIN. DSA APPROVED SEISMIC STRAPS APPLIED PER MANF. SPECS VENT THE FOLLOWING WINDOW SIZES WILL BE THE MINIMUM ALLOWED FOR EGRESS UNLESS MANF. DATA IS SUPPLIED 20" CLEAR STANDARD 6'-8" HEADER HEIGHT 41" CLEAR 34-1/8" CLEAR OPENABLE 24" CLEAR OPENABLE SINGLE CASEMENT: 2-4 x 4-0 2-6 x 3-6 DOUBLE CASEMENT: 4-8 x 4-0 CASEMENT/ FIXED COMBO: 7-0 x 4-0 OTHER WINDOW TYPES AWNING: NONE W/O MANF. DATA BAY W/ FIXED CENTER: NONE W/O MANF. DATA MIN. SIZE WINDOW FOR 20" CLEAR WIDTH FOR 24" CLEAR HEIGHT 44" MAX. MIN. SIZE WINDOW 44" MAX. AREA FLOOR LEVEL 1. 20" MIN. CLEAR WIDTH SINGLE/ DOUBLE HUNG: 3-0 x 5-0 3-0 x 5-6 3-4 x 5-0 3-8 x 5-0 4-0 x 5-0 SINGLE/ FIXED COMBO: NONE W/O MANF. DATA 2. 24" MIN. CLEAR HEIGHT 3. 5.7 SF MIN. OPENABLE AREA EMERGENCY ESCAPE/ EXIT WINDOW (CBC 310.4) EMERGENCY ESCAPE/ EXIT WINDOW (CBC 310.4) PIPE DEPTHS TO 3'-0" MAX. BELOW FOOTING 1'-6" MIN. 6" MIN. 45° NO PIPES THIS AREA 6" 8" PIPE DIA. + 2" 1/2" CLEAR- ALL SIDES, END, AND TOP NOTE: SIZES ARE TAKEN FROM DATA SUPPLIED BY WINDOW MANUFACTURERS, HOWEVER THESE ARE GENERAL DIMENSIONS. IT IS THE OWNERS RESPONSIBILITY TO VERIFY THAT THE ACTUAL WINDOWS INSTALLED MEETTHE MINIMUM EGRESS REQUIREMENTS. 6 CONC.FOUND. WALL FLOOR GIRDER P.T. SILL 3" MIN. BEARING WIDTH OF FOOTING x WIDTH OF TRENCH (MIN. SLEEVE + 18") TRENCHES AT FOOTINGS SLIDER: 4-0 x 4-0 5-0 x 3-6 6-0 x 3-0 SLIDER/ FIXED COMBO: 8-0 x 4-0 10-0 X 4-0 12-0 X 3-0 44" MAX AREA 6 GIRDER (CBC 2320.7/ 2306.6) LARUCP/TYPEV1.2 12/2001 LIGHT : (CBC 1203.2) ALL HABITABLE ROOMS, EXCEPT BATHROOMS, KITCHENS, AND LAUNDRIES REQUIRE NATURAL LIGHT BY MEANS OF EXTERIOR WINDOWS OR SKYLIGHTS @ 1/10 THE FLOOR AREA OF THE ROOM, OR 10 SF MINIMUM, WHICHEVER IS GREATER. SMOKE DETECTORS: (CBC 310.9) IN SINGLE FAMILY DWELLING UNITS SMOKE DETECTORS ARE REQUIRED WHEN THE VALUATION OF AN ADDITION, ALTERATION, OR REPAIR EXCEEDS $1000.00. IN NEW CONSTRUCTION, 120V WITH BATTERY-BACK-UP SMOKE DETECTORS ARE REQUIRED IN EXISTING CONSTRUCTION BATTERY-OPERATED DETECTORS ARE PERMITTED LOCATE SMOKE DETECTORS IN BEDROOMS, AND HALLWAYS OR ADJACENT ROOMS LEADING TO BEDROOMS SD LIVING WASHER & DRYER- DRYER VENT 4"¯ MIN.; 14' MAX. W/ TWO 90° BENDS FOR METAL DUCT; 6' MAX. FOR FLEX DUCT CONNECTOR ALL WINDOWS WITHIN 24" OF DOOR SHALL BE TEMPERED (CBC 2406.4) MINIMUM ROOM DIMENSIONS: (CBC 310.6) AT LEAST ONE ROOM 120 SF ALL OTHER ROOMS EXCEPT KITCHEN 70 SF WITH A MIN. DIMENSION OF 7'-0" SD HALL SHOWER & TUB ENCLOSURES SHALL BE TEMPERED (CBC 2406.4) WINDOWS AT SHOWERS & TUBS SHALL BE TEMPERED, IF LESS THAN 60" ABOVE A STANDING SURFACE AND DRAIN INLET (CBC 2406.4) SD 12"X12" TUB ACCESS BATHROOMS MAY HAVE MECHANICAL VENTILATION PROVIDING 5 AIR CHANGES PER HOUR (CBC 1203.3) DINING VENTILATION: (CBC 1203.3) ALL HABITABLE ROOMS, EXCEPT BATHROMS, AND LAUNDRIES REQUIRE NATURAL VENTILATION BY MEANS OF OPENABLE WINDOWS @ 1/20 THE FLOOR AREA OF THE ROOM, OR 5 SF MINIMUM. (NATURAL VENTILATION MAY BE SUBSTITUTED WITH MECHANICAL VENTILATION). ALL BATHROOMS REQUIRE NATURAL VENTILATION BY MEANS OF OPENABLE WINDOWS @ 1/20 THE FLOOR AREA OF THE ROOM, OR 1-1/2 SF MINIMUM. (NATURAL VENTILATION MAY BE SUBSTITUTED WITH MECHANICAL VENTILATION, AS NOTED IN EXAMPLE). BEDROOM SD 30" MIN. 70" HIGH NON-ABSORBENT FINISH @ SHOWER WALL (CBC 807.1.3) 24" MIN. CLEAR IN FRONT OF TOILET (CBC 2904) 18"X24" UNDERFLOOR ACCESS (UBC 2306.3) ALTERNATE 18"X24" UNDERFLOOR ACCESS FROM EXTERIOR BEDROOM KITCHEN PER LOCAL ZONING ORDINANCE 22"X30" ATTIC ACCESS, OR 30"X30" IF FURNACE IS IN ATTIC AND EQUIPMENT WILL NOT PASS THROUGH 22"X30" ACCESS. MIN. HEADROOM IS 30". (CBC 1505.1 & CMC) PIPE BOLLARD OR OTHER PROTECTIVE MEASURE WHEN APPLIANCES ARE SUBJECT TO DAMAGE. 2" MIN. DIA. WHERE GARAGES ARE ATTACHED TO THE RESIDENCE, THE WALL ON THE GARGE SIDE SHALL BE PROTECTED WITH 5/8" TYPE 'X' GYP. BD. THE DOOR SHALL BE A SELF-CLOSING, TIGHT-FITTING 1-3/8" SOLID CORE DOOR. (CBC 302.4) NOTE: THE GARAGE SHALL NOT OPEN INTO A SLEEPING ROOM. GARAGE RESIDENTIAL REQUIREMENTS 7 LARUCP/TYPEV1.2 12/2001