E2T Model M7000SR Series THREE INFRARED TEMPERATURE MEASUREMENT SYSTEMS FOR SULFUR REACTORS AND OTHER HIGH TEMPERATURE FURNACES COMPLEX PROCESSES Optimal operation of your Sulfur Recovery Unit (SRU) requires measurement and control of a complex sequence of processes. Particularly important is control of the reaction furnace temperature to prevent damage to the refractory at high temperatures and ammonium salt plugging the converters at low temperatures. Those installations that use the reaction furnace to incinerate waste gases such as ammonia and hydrocarbons must maintain an adequate temperature to assure their destruction. Advanced processes such as O2 enrichment normally involve still higher temperatures and demand close monitoring. CONTINUOUS TEMPERATURE MONITORING ✰ INSTANTANEOUS READINGS ✰ GAS, REFRACTORY AND INTEGRATED TEMPERATURE MEASUREMENTS ✰ PROCESS CONTROL ✰ CSA AND CENELEC CERTIFICATION TEMPERATURE SYSTEMS Mikron E2T applies sophisticated infrared technology to the solution of your furnace temperature measurement requirements. Mikron E2T has designed the PULSAR family of three detection systems for continuous and instantaneous measurement of Refractory Temperature (RT), Gas Temperature (GT) and Integrated Temperature (FF) in the vessel away from the heat, vibration and corrosive gases. Each system allows visual inspection of combustion processes, refractory cure-out and preventative maintenance while the vessel is pressurized and fully operational. WE MAKE INFRARED WORK FOR YOU SELECT AND INSTALL SYSTEMS T Selection Criteria Over 350 refineries, gas plants and petrochemical companies with over 1250 installations world-wide have looked to E2TECHNOLOGY for accurate infrared (IR) temperature data. When you install Mikron E2T’s Refractory Temperature (RT), Gas Temperature (GT) and Integrated Total Temperature (FF) IR thermometers, you are investing in proven experience, superior performance and ultimate cost savings. PROVEN EXPERIENCE For a quarter of a century the energy industry has used Mikron E2T pyrometers in sulfur reaction furnaces, spent acid plants, CO boilers and sulfur burners. Mikron E2T listens when industry speaks, and when clients asked us whether we could manufacture furnace temperature measurement systems with multiple capabilities, we accepted the challenge. SUPERIOR PERFORMANCE Industry wanted the capability to choose refractory, gas or integrated temperature measurement and not simply accept a single temperature of unknown origin. Mikron E2T, utilizing SRU test facilities, designed three separate models to meet this request. PULS MODEL M7000SR E INFRARED TH CSA CL1 Div 1 Div 2 GRPS ABCD Industry wanted systems designed for air and higher temperature oxygen-enriched reactors instead of generic thermometers with limited temperature spans of 1000°C. Mikron E2T increases the range of its sulfur reactor models to 900°-3500°F (480°-1925°C). Industry wanted a simple but rugged monitoring system with cooling capabilities able to withstand continuous exposure to corrosive gases and temperature extremes. Mikron E2T builds monitors with heavy-duty swing-out fixtures and cooling cavities. Industry wanted an explosion-proof housing as standard without expensive X and Y purge additions. Mikron E2T delivers CSA and CENELEC-certified IR Systems in Explosion-proof Housings Industry wanted to visually see what the IR thermometer was measuring rather than guessing on what you are focusing. Mikron E2T provides sight-through optics for viewport and furnace viewing. MODEL SWING-OU For Sight-p Industry wanted to easily clean the window and clear the viewport of debris during operations without waiting for a shutdown to resume thermometer readings. Mikron E2T includes a removable viewport window and a clean-out probe assembly. Industry wanted to safely field verify the IR thermometers during full operations instead of depending upon dedicated thermocouples that burn out. Mikron E2T includes a thermocouple probe assembly for verification and cure-out operations. MODEL THERMOCOUPLE For Start-up an 2 Mikron E T LISTENS WHEN INDUSTRY SPEAKS! COST SAVINGS Industry required enhanced capability systems at reasonable prices. Rather than introducing a basic generic instrument and then adding various required expensive accessories, Mikron E2T introduces complete systems at lower cost with a choice of refractory, gas, or integrated total temperatures. Well-designed superior performing IR systems do not need to cost more, especially if you listen when industry speaks. MODEL CLEAN-O For Clearing THAT MEET YOUR REQUIREMENTS Installation Principles LOCATION ON FURNACE Utilization of the different temperature measurement systems depends upon the feed gases and burner design of the reactor. If you burn simple acid gas with combustion air, the FF Integrated Total Temperature System should be installed two-thirds of the way downstream from the burner to the waste heat boiler. If there is a checker wall or choke ring, installation at Locations 2 and 3 are recommended. When you are using your reactor to destroy ammonia and/or other gases such as BTEX, it is essential that destruction temperatures be achieved. To assure incineration, the FF Integrated Total Temperature System or the GT Gas Temperature System should be installed at Locations 2 and 3. AR XPLOSION-PROOF ERMOMETER GRPS C and D CENELEC EExd IIB T4 With oxygen-enrichment, refractory integrity becomes critically important. Burner design and location become paramount in determining the placement of the IR thermometer. The RT Refractory Temperature System should be installed aimed at the area where the designers anticipate the highest refractory temperatures. For example, Location 1 is recommended for checker wall protection and Location 4 for tube sheet monitoring. Temperatures at the tube sheet are especially critical since the ferrules and ceramic tube-to-metal junctions may face potential excessive temperature excursions as a result of oxygen-enrichment operations. SOF-8 T FIXTURE ort Access MOUNTING TO FURNACE The PULSAR Model M7000SR should be mounted on the horizontal diameter (no greater than +35°) perpendicular to the vessel sighting on refractory, or adjacent to the burner sighting on the checker wall or tube sheet. BUP-10 AND ADAPTER d Verification COP-10 UT ROD Sight-port The SOF-8 Swing-out Fixture mounts to a 3 inch 150 or 300 pound valve connected to the furnace via a spool with purge connection. Minimum purge rates for downstream and viewport are 10 SCFM and 1 SCFM respectively. The PULSAR’s housing includes a cavity for water or vortex air cooling when ambient temperatures exceed 125°F (50°C). Flex lines should be used for power input and signal output. PULSAR SPECIFICATIONS General Specifications of the PULSAR M7000SR Model Type RT - Refractory Surface Temperature FF - Average Integrated Total Temperature GT - Highest Gas Temperature TEMPERATURE RANGE Models RT and FF Single Continuous Range NIST Calibrated to Your Specification Model GT 400°-3000°F 205°-1650°C 600°-3000°F 315°-1650°C Up to 4170°F Up to 2300°C Up to 4170°F Up to 2300°C ACCURACY ±1% Reading or ±5°C; ±1 Digit whichever is greater RESPONSE TIME Switchable internally 1 or 5 seconds OUTPUT 1mV/° and 4-20 mA EMISSIVITY ADJUSTMENT 0.01 to 0.99 digital FOCUSING RANGE 20” to infinity - Standard TARGET SIZE 150:1 MOUNTING 3” 150 or 300# RF POWER REQUIREMENTS 115 VAC ±10%, 50/60 Hz 230 VAC +10%, 50/60 Hz 95 Watts including heater, 15 Watts less heater Voltage is factory set AMBIENT LIMITS A. 40° to 120°F (5° to 50°C) B. 120° to 200°F (50° to 95°C) with cooling base and 10 GPH (38 LPH) water flow at 60°F (15°C) or vortex air cooler (optional) with 100 psig source C. Both cooling methods can accommodate higher ambient temperature by increasing flow rates;consult factory D. -40° to 32°F (-40° to 0°C) with standard electric heater installed EXPLOSION-PROOF CERTIFICATION CSA: Class 1, Division 1, Groups C and D Class 1, Division 2, Groups A through D Temperature Code T4A CENELEC: EExd IIB T4 Mikron E2T has 25 years experience providing infrared thermometer systems to sulfur reactor users. Our clients have made us the leader in the industry. Sulfur reactor engineering companies and consultants recommend and specify Mikron E2T as the definitive solution to real-time temperature measurement problems. The technology is proven in installations worldwide and is backed by continued research into new processes with a one-year warranty. Technical papers are available upon request. Mikron Infrared Inc., Headquarters 16 Thornton Road Oakland, NJ 07436 USA Tel: 201-405-0900 Tel: (USA only) 800-631-0176 Fax: 201-405-0090 E-mail: sales@mikroninfrared.com Mikron E2T has developed a comprehensive seminar on infrared temperature measurement in sulfur reactors. We will be pleased to send you a complimentary abstract of the seminar material. We also provide on-site training for your instrumentation personnel. Please contact us at: Visit our websites: www.mikroninfrared.com West Coast Office: Mikron www.IRimaging.com 4475 Dupont Court #9 Ventura, CA 93003 Infrared Temp. Rev. 0 Tel: 805-644-9544 070210 Fax: 805-644-9584 Printed in USA E-mail: sales@e2t.com