Elixir-T

advertisement
Elixir-T
Compact Vibrating Fork Type Level Limit Switch
Grown...to meet challenges
Features
• Power supply
11-55 VDC
• Compact Instrument Size
Easy to install.
• Service friendly plug in connection
• Output
Open collector PNP
LED Indication
• Operational temperature
Standard Model upto 80°C
• Rugged stainless steel housing
• Operational Safety, Reliability
• No Calibration required
• External circuit testing by test magnet
About Elixir - T
Various Parts
Elixir-T is a compact level switch suitable for all
kinds of liquids and is used in tanks, containers
and pipelines. Pipe fork is used in all types of
liquids having viscosity upto 10,000 cP & densities
greater than or equal to 0.7gm/cc.
Quick ON
Valve Connector
Side Conduit
Cable Entry
Principle
Elixir-T works on the principle of continuous
vibration of the fork at its natural frequency. A
specially shaped tuning fork is kept vibrating by
piezo electric elements. The resonant frequency of
the fork changes when the tines are immersed in a
fluid. The change in frequency is detected and
used for switching. The open collector PNP O/p can
be used to energise relay or as input to PLC.
Stainless Steel
Housing
110 MM
O 40
Application
• Pharmaceutical
• Chemicals
• Pesticides
•
•
•
•
Edible oil
Packaging
Food & Brewery
Dairy
3/4" BSP / NPT
Mounting Threads
65 MM
Fork
Technical Specification
System Diagram
Mechanical
Housing
Cast aluminum weather proof
Mounting
Screwed
11/4" - 11/2" BSP/NPT(M)
Flange
Material
As per order
MS (Plated)
Cable Entry
2 X 1/2" BSP/NPT, Brass
Gland Type
Single/Double compression gland/
PG 13.5
Dimension
Refer Drawing/Customer Support
Probe
PLC
4-20 mA
Level 100%
Level 55%
Metallic Tank
Rod type
Sense Rod (SS), Full PTFE
Rope type
Single Rope, Full/Part PTFE
Measuring Range
Level
Nonmetallic Tank
Rod type
Sense Rod (SS), Full PTFE
Steelwell (GI/SS)
Rope type
Twin Rope, Full/Part PTFE
Electronic Insert
Indication
Two LEDs for
Fault indication and calibration
Input Supply
24-50 VDC @ 750 ohm
Current
consumption
20mA maximum
Output
Analog Output(4-20mA)
Temperature
range
0°C to 60°C
Internal
Enclosure
ABS
Level 0%
Application Diagram
Installation of Various Probes
Measurement
Measurement
span
15 to 3000 pf above zero
Response
Time
3 sec.(typical)
Accuracy
+/- 2 % of full scale
Note: Add suffix "FLP" to standard model code
to identify that it is Flameproof.
Why Sapcon
• Prompt and quick delivery
• Customization and new technology
• Complete range of instruments
SOYA OIL
CHEMICAL
WHEAT
WATER
DIESEL
• Flexibility and interaction with management
V 1.1
Download