SW6000 ELECTRONIC VIBRATION SWITCH Datasheet OVERVIEW This electronic switch is a versatile excessive vibration protection instrument. In its standard configuration, the SW6000 is an economical single set point vibration switch loaded with standard features and packaged in an industrial grade housing. Fully configured, the SW6000 provides for local machine control with optional LCD readout, real time remote operator interface via 4-20 mA and an external BNC (weather-proof only) for easy analyst access to the buffered dynamic vibration signal. Optional hazardous area certifications. FEATURES • • • • • • • Low cost, unitized protection system Weatherproof/optional ex-proof rated Single or optional dual setpoint Velocity or displacement response Adjustable trip delay Setpoint test feature Buffered, dynamic vibration signal output for analysis APPLICATIONS • • • • • • • Centrifugal Pumps Reciprocating Compressors Centrifuges Cooling Towers Industrial Fans Electric Motors Natural Gas/Diesel Engines C US 1180 TYPICAL INSTALLATIONS switch CENTRIFUGAL PUMP/MOTOR ENGINE COMPRESSOR www.metrixvibration.com • dps@metrixvibration.com • 281.940.1802 Doc# 1009462 • SW6000 • Mar2016-RevF • Page 1 of 3 SW6000 ELECTRONIC VIBRATION SWITCH Datasheet WEIGHT & DIMENSIONS Units: mm [in] Weight: 2.2 kg [4.4 lbs] Note: 1) Optional BNC connector and weatherproof reset button available only on non-agency approved locations. 2) Cover locking set screw on ATEX/IECEx versions only. SPECIFICATIONS Sensor Internal piezoelectric accelerometer Signal Conditioner Amplifier/integrator to obtain velocity or displacement response. Triac Outputs Optional Buffered, Dynamic Signal Output “A” = 1, 2, 5 or 6; 250 VAC, 1A, optically isolated; standard is N.C. (fail-safe), N.O. field selectable Sensitivity: 100 mV/g ±2% @ 25°C. Frequency Response: • Acceleration: 2 Hz to 500 Hz • Non-linearity: Less than 1% of full scale (F.S.) Field Wiring Maximum Vibration Input 0 to 490 m/sec2 (50 g), peak; 0 to 100 mm/ sec (4 in./sec), peak Maximum wire gauge: 14 AWG; Wire clamp type screw terminal block 500 Vrms isolation from circuit Housing Weatherproof aluminum cast Frequency Response • Velocity: 2 Hz to 500 Hz • Displacement: 2 Hz to 200 Hz Adjustable Trip Delay Factory set at 1 sec.; 1-15 sec adjustable Temperature Limits • No Display: -40° to +85°C (-40° to +185°F) • W/Display: -10° to +70°C (+14° to +158°F) Output Sensitivity vs Temperature Less than .05%/°C (calibrated at 25°C) Cross Axis Response Less than 10% Input Power Option C • Nom. 115 VAC, 95 to 125, 50/60 Hz • Nom. 230 VAC, 190 to 250, 50/60 Hz • Nom. 24 VDC, 20 to 28 Galvanic Isolation Power from circuit Environmental Rating NEMA 4/4X Electromagnetic Compatibility CE Marked Optional Hazardous Area Certification Ordering Options “D” Optional Display 2½ digit LCD (Ordering Option “A”) Optional FET Transistor Output 50 VDC, 0.5 A, N.C. (fail-safe) standard, N.O. field selectable Optional 4-20 mA Source Output Proportional between 4-20 mA with 20 mA set to full scale. Zero and Span calibrated ±2%. Non-linearity < 2%. 600 ohms maximum load resistance. www.metrixvibration.com • dps@metrixvibration.com • 281.940.1802 Doc# 1009462 • SW6000 • Mar2016-RevF • Page 2 of 3 SW6000 ELECTRONIC VIBRATION SWITCH Datasheet HOW TO ORDER A B B C -D E F SW6000- - Without Display Input Power 1 115 VAC, single phase, 50/60 Hz 1 one limit, triac 2 230 VAC, single phase, 50/60 Hz 2 two limit, triacs 3 20 - 28 VDC A Limits and Displays C 3 one limit, FET 4 two limits, FETs D Certifications Local Reset Options With Display 2 CSA, US/C, Class I, Div 1, Groups B, C & D, T4A, NEMA 4/4X 5 one limit, triac 3 CSA, US/C, Class I, Div 1, Groups B, C & D, T4A, NEMA 4/4X w/ external reset 4 ATEX/IECEx Ex d IIB + H2 T4 Gb 5 ATEX/IECEx Ex d IIB + H2 T4 Gb with external reset 8 Non-agency approved locations 9 Non-agency approved locations with external reset E Input/Output Options 6 two limit, triacs 7 one limit, FET 8 two limits, FETs Note: Use triacs in motor starter circuits. FET transistor output(s) recommended for PLC DC inputs. B B Full Scale Range Velocity Response 0 No options 0 1 1.0 in/sec (25.4 mm/sec) peak 2 External BNC for dynamic signal access* 0 2 2.0 in/sec (50.8 mm/sec) peak 5 0 3 20 mm/sec (0.79 in/sec) peak 4-20 mA proportional to full scale range and separate startup and monitor time delays 0 4 50 mm/sec (1.97 in/sec) peak 7 Options 2 & 5* 3 1 1.0 in/sec (25.4 mm/sec) true RMS 3 2 2.0 in/sec (50.8 mm/sec) true RMS 3 3 20 mm/sec (0.79 in/sec) true RMS 3 4 50 mm/sec (1.97 in/sec) true RMS Displacement Response 5 1 20 mils, (508 microns) peak 5 2 50 mils, (1270 microns) peak 6 1 200 microns, (7.87 mils) peak 6 2 500 microns, (19.69 mils) peak * D= 8 or 9 only F Mouting/Conduit Entries 0 1/2” NPT stud mount/ 3/4” NPT conduit entry 1 M20 x 1.5 stud mount/ M20 x 1.5 conduit entry 2 1/2-20 UNF stud mount/ 3/4” NPT conduit entry 3 3/4” NPT stud mount/ 3/4” NPT conduit entry ACCESSORIES Part Number 7084-001 Name Flange Mounting Adapter Description Stainless Steel adapter for surface mount the SW6000. 1/2” NPT center hole. Three equally spaced 6.6 (.26) diameter mount holes on 38 (1.50) diameter circle Used with Any SW6000 with 1/2” NPT stud (“F”= 0) Weight: 0.5 kg [1 lb] www.metrixvibration.com • dps@metrixvibration.com • 281.940.1802 Doc# 1009462 • SW6000 • Mar2016-RevF • Page 3 of 3