1L Incandescent Luminaires Hazardous and Non

advertisement
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0691-2 Name: 1L-691
100:
DATE: JAN 19 2006
Time: 5:44:25 PM Operator: RB
COLOR: CMYK
TCP: 15001
Incandescent Luminaires
Hazardous and Non-Hazardous
Typedriver Name: TS name csm no.: 100
1L
Description
Page No.
Application
692
Industrial Luminaires
Vaporgard TM Series
V Series
NDA CorroɀGard TM Series
US: 1-866-764-5454
STIBOINFO((CRH:66008com:1L:691))
CH0 0 0 0 1 L
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
693-701
702-705
706, 707
691
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0692-3 Name: 1L-692
1L
100:
DATE: JAN 19 2006
Time: 5:44:25 PM Operator: JB
Enclosed and Gasketed
General Information
Application:
TCP: 15001
Table 500-3(d)
Identification Numbers.
Features:
ɀ Enclosed and gasketed luminaires that
accept incandescent lamps
ɀ Gaskets and glass globes help prevent dirt,
water and corrosive atmosphere from
entering the conduit system and corroding
the interior parts
Standard Materials:
Maximum
Temperature
Deg. C
Deg. F
450
842
300
572
280
536
260
500
230
446
215
419
200
392
180
356
165
329
160
320
135
275
120
248
100
212
85
185
Identification
Number
T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
ɀ Luminaires-bodies, boxes and guards –
copper-free aluminum or Feraloy® iron alloy
ɀ Globes – heat-resistant glass or
polycarbonate
ɀ Reflectors – Krydon® fiberglass-reinforced
polyester
Standard Finishes:
ɀ Vaporgard TM – copper-free aluminum-epoxy
powder coat
ɀ V SERIES, – Feraloy iron alloy –
electrogalvanized and aluminum acrylic paint
ɀ Krydon material – luminaires: gray;
reflectors: high reflectance white
Size Ranges:
ɀ Include up to 300 watt, PS-30 lamp
ɀ 1⁄2⍯ to 11⁄4⍯ hubs
Certifications and
Compliances:
ɀ Weather resistant, NEMA 3, 3R
ɀ NEC/CEC: Class I, Division 2
ɀ UL Standard: 1598
ɀ CSA Standard: C22.2
692
STIBOINFO((CRH:66008com:1L:692))
CH0 0 1 L - 1
US: 1-866-764-5454
CAN: 1-800-265-0502
Typedriver Name: TS name csm no.: 100
CI. I, Div. 2, Groups A, B, C, D
Weather Resistant
Incandescent Luminaires
Incandescent luminaires are used:
ɀ indoors or outdoors in industrial locations
ɀ in tunnels, building entrances or similar
locations, where moisture, dirt, chemicals,
vibration or rough usage are a problem
ɀ either mounted directly in the conduit
system or attached to cast outlet boxes, by
means of pendant, ceiling, wall bracket or
stanchion mountings
COLOR: CMYK
Copyright© 2006 Cooper Crouse-Hinds
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0693-4 Name: 1L-693
100:
DATE: JAN 19 2006
Time: 5:44:26 PM Operator: RB
VAPORGARD TM Incandescent
Luminaires
Standard Materials:
Vaporgard series incandescent luminaires
are used:
ɀ indoors or outdoors in industrial locations
where enclosed and gasketed fixtures are
required
ɀ in tunnels, building entrances and similar
locations, where moisture, dirt, chemicals,
vibration or rough usage are a problem
ɀ for flush or surface mounting on ceiling or
wall; pendant or in conduit systems; with or
without a cast outlet box
ɀ Bodies and guards – copper-free aluminum
ɀ Globes
– heat and impact resistant
tempered glass
– colored glass nontempered (G55,
G56, G57, G58)
– plastic polycarbonate (G63, G65,
G67)
ɀ Reflectors – Krydon® fiberglass-reinforced
polyester
Features:
ɀ Bodies and guards – epoxy powder coat
ɀ Krydon material – high reflectance white
®
Krydon fiberglass-reinforced polyester
reflectors
ɀ Reflectance is equivalent to the finest
porcelain enamel
ɀ Cannot corrode – no enamel to chip and
rust
ɀ Ultraviolet inhibitors are incorporated in the
material to prevent discoloration and
brittleness
Typedriver Name: TS name csm no.: 100
1L
Standard Finishes:
Options:
The following options are available from the
factory by adding suffix to fixture Cat. No.:
Suffix to be
Description
Added to Cat.
No.:
ɀ Teflon coating on globe
for increased shatter
protection (G24 globe
200 watt series only)
S808
ɀ 250V nameplate for
export applications
/250
ɀ Plastic polycarbonate
globe
See page 696
Ratings (Electrical/Size):
ɀ Up to 300 watt, PS-30 medium base lamp
ɀ 1/2⍯ to 1-1/4⍯ hubs
ɀ 120V nameplate is standard – for NEC
compliance
ɀ 250V nameplate is optional. Supplied when
ordered with suffix: /250
Certifications and
Compliances:
ɀ Wet locations
ɀ NEC/CEC: Class I, Division 2
ɀ UL Standard: 1598
ɀ CSA Standard: C22.2 No. 9
ɀ UL/CSA Fixture Fitting
US: 1-866-764-5454
STIBOINFO((CRH:66008com:1L:693))
TCP: 15001
Cl. I, Div. 2, Groups A,B,C,D
(All mounting except stanchion)
Wet Locations
NEMA 3,3R
Application:
ɀ Designed to exclude dirt, moisture and
corrosive vapors from the interior of the
luminaires and the conduit system
ɀ There are no screws to remove as the
shock-absorbing socket strap is keyhole
slotted and removes quickly for ease of
wiring
ɀ The glass globe-guard assembly is
installed and/or removed as a unit, making it
necessary to handle only one piece in
relamping
ɀ There are no crevices to accumulate a dirt
or dust buildup and fixture has an attractive
finish with a smooth, dust and dirt shedding
design
ɀ Configurated glass globe has vertical fluting
and stippled bottom which provides for more
even light distribution and glare elimination
ɀ For non-hazardous locations, shatterproof
plastic polycarbonate globes are available for
use with the 200 watt series.
ɀ Reversible offset socket mounting strap
permits use of various size lamps while
holding light center in same position for
maximum light output and efficiency
ɀ Shock absorbing medium base lamp
socket
CH0 0 1 L - 2
COLOR: CMYK
CAN: 1-800-265-0502
Class I, Division 2
Temperature Performance Data:
(Based on 40° C ambient)
Lamp
Watts
T-Number
Supply
Wire
°C
150
200
300
T2A
T2B
T2B
150°C
200°C
150° C
Copyright© 2006 Cooper Crouse-Hinds
693
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0694-2 Name: 1L-694
1L
100:
DATE: JAN 19 2006
Time: 5:44:27 PM Operator: RB
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
Cl. I, Div. 2, Groups A,B,C,D
Wet Locations
NEMA 3,3R
VAPORGARD TM Incandescent
Luminaires
Enclosed and Gasketed
Luminaire Components
Catalog Nos.
Pendant Mount VDA Series
Thru-Feed VDC Series
Hub
Max Lamp
Size Series Size
Complete Cat.#
with globe/guard
Pendant
Body
Globe
Guard
1⁄2⍯
VDA15GP
VDA25GP
VDA15
VDA25
G54
G54
P50
P50
VDA35GP
VDA35
G54
P50
VDA12GP
VDA22GP
VDA12
VDA22
G24
G24
P21
P21
VDA32GP
VDA32
G24
P21
VDA13GP
VDA23GP
VDA13
VDA23
G34/G251 P22
G34/G251 P22
VDA33GP
VDA33
G34/G251 P22
Hub
Max Lamp
Size Series Size
Complete Cat.#
with globe/guard
Thru Feed
Body
Globe
Guard
1⁄2⍯
3⁄4⍯
150
150
1⍯
150
1⁄2⍯
3⁄4⍯
200
200
1⍯
200
1⁄2⍯
3⁄4⍯
300
300
1⍯
300
150 watt
A-21
200 watt
A-23
300 watt
PS-25 & PS-30
150
150
150 watt
A-21
VDC15GP
VDC25GP
VDC15
VDC25
G54
G54
P50
P50
200
200
200 watt
A-23
VDC12GP
VDC22GP
VDC12
VDC22
G24
G24
P21
P21
300
300
300 watt
PS-25 & PS-30
VDC13GP
VDC23GP
VDC13
VDC23
G34/G251 P22
G34/G251 P22
Hub
Max Lamp
Size Series Size
Complete Cat.#
with globe/guard
Lamp
Socket
Body
Globe
Guard
1⁄2⍯
150
150 watt
A-21
VXH15GP
VXH15
G54
P50
1⁄2⍯
200
VXH12GP
VXH12
G24
P21
1⁄2⍯
300
200 watt
A-23
300 watt
PS-25 & PS-30
VXH13GP
VXH13
G34/G251 P22
Hub
Size
Max Lamp
Series Size
Complete Cat.#
with globe/guard
Lamp
Socket
Body
Globe
Guard
Junction
Box
1⁄2⍯
150
150
150 watt
A-21
VXHF15GP
VXHF25GP
VXH15
VXH15
G54
G54
P50
P50
VXF10
VXF20
200
200
200 watt
A-23
VXHF12GP
VXHF22GP
VXH12
VXH12
G24
G24
P21
P21
VXF10
VXF20
300
300
300 watt
PS-25 & PS-30
VXHF23GP
VXHF23GP
VXH13
VXH13
G54/G251 P22
G34/G251 P22
VXF20
VXF20
3⁄4⍯
1⁄2⍯
3⁄4⍯
1⁄2⍯
3⁄4⍯
Ceiling Mount for
Recessed 4⍯ Round
Box - VXH Series
Ceiling Mount with
Junction Box VXHF Series
3⁄4⍯
1⁄2⍯
3⁄4⍯
1⁄2⍯
3⁄4⍯
– available with Lightning Service TM
See Section G for complete details
694
STIBOINFO((CRH:66008com:1L:694))
CH0 0 1 L - 3
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0695-2 Name: 1L-695
100:
DATE: JAN 19 2006
Time: 5:44:28 PM Operator: JB
VAPORGARD TM Incandescent
Luminaires
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
Cl. I, Div. 2, Groups A,B,C,D
Wet Locations
NEMA 3,3R
1L
Enclosed and Gasketed
Wall Mount VXHT Series
Luminaire Components
Catalog Nos.
Hub
Max Lamp
Size Series Size
Complete Cat.#
with globe/guard
Wall
Bracket
Mounting
Module Body
1⁄2⍯
3⁄4⍯
1⁄2⍯
3⁄4⍯
1⁄2⍯
3⁄4⍯
Wall Mount Adapter Kit
Globe
Guard
150
150
150 watt
A-21
VXHT15GP
VXHT25GP
VXT10
VXT20
VXH15
VXH15
G54
G54
P50
P50
200
200
200 watt
A-23
VXHT12GP
VXHT22GP
VXT10
VXT20
VXH12
VXH12
G24
G24
P21
P21
300
300
300 watt
VXHT13GP
PS-25 & PS-30 VXHT23GP
VXT10
VXT20
VXH13
VXH13
G34/G251 P22
G34/G251 P22
Mounts wall mount VXHT Series
to a 4⍯ Round Box.
Cat. No. VXT-K1
Wall Mount with
Junction Box
VXHBF Series
Hub
Max Lamp
Size Series Size
Complete Cat.#
with globe/guard
Wall
Bracket
Mounting
Module Body
1⁄2⍯
3⁄4⍯
1⁄2⍯
3⁄4⍯
1⁄2⍯
3⁄4⍯
Stanchion Mount VXHA Series
Junction
Guard Box
150
150
150 watt
A-21
VXHBF15GP
VXHBF25GP
VXT10
VXT20
VXH15
VXH15
G54
G54
P50
P50
VXF10
VXF20
200
200
200 watt
A-23
VXHBF12GP
VXHBF22GP
VXT10
VXT20
VXH12
VXH12
G24
G24
P21
P21
VXF10
VXF20
300
300
300 watt
VXHBF13GP
PS-25 & PS-30 VXHBF23GP
VXT10
VXT20
VXH13
VXH13
G34/G251 P22
G34/G251 P22
VXF10
VXF20
Complete Cat.#
with globe/guard
Stanchion
Mounting
Module Body
Globe
Guard
VXHA45GP
VXA4
VXH15
G54
P50
200 watt
VXHA42GP
A-23
300 watt
VXHA43GP
PS-25 & PS-30
VXA4
VXH12
G24
P21
VXA4
VXH13
G34/G251 P22
Hub
Max Lamp
Size Series Size
1
Globe
1⁄4⍯
1 1⁄4⍯
1 1⁄4⍯
150 watt
A-21
– available with Lightning Service TM
See Section G for complete details
US: 1-866-764-5454
STIBOINFO((CRH:66008com:1L:695))
CH0 0 1 L - 3
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
695
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0696-7 Name: 1L-696
DATE: JAN 19 2006
Time: 5:44:30 PM Operator: RB
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
VAPORGARD TM Incandescent
Luminaires
1L
Parts and Accessories
Medium Base
Lamp Receptacle
with Strap
Plastic Globes 1
Globes† and Guards
Shock Absorbing
Cat. #
V84
150 and 200W
globe
300W globe
Reflectors
Color
Clear
(heatresisting)
Green
Blue
Red
Amber
Dome
Maximum Lamp Size
150 Watt, 200 Watt, 300 Watt,
A-21
A-23, A-25, PS-25
PS-25
PS-30‡
Application:
Cat. #
Cat. #
Features:
G54
G55*
G56*
G57*
G58*
G24ɍ
G25
G26
G27
G28
Cat. #
G34 {G251
30° Angle
Max.
Lamp
Size
150 watt,
A-21
200 watt,
A-23, A-25,
PS-25 and
300 watt,
PS-30
Dome
Cat. #
RD64
30° Angle
Cat. #
RA64
RD71
RA71
Shatterproof
polycarbonate
plastic globe**
Guard P50
and P21
Guard P22
Guards for Glass Globes (Not for use with
plastic globes)
Cat. #
Maximum Lamp Size
P50 150 watt, A-21
P21 200 watt, A-23, A-25, PS-25
P22 300 watt, PS-30 (with G251 only)
For use in:
ɀ food processing plants and canneries,
dairies, breweries and bakeries
ɀ emergency lighting
ɀ Shatterproof, which precludes
contamination of food products with broken
particles of glass.
ɀ Designed to comply with U.S. Dept. of
Agriculture specification for food processing
plants.
ɀ Provides protection against vandalism, with
resultant lower replacement and
maintenance costs.
ɀ Particularly adaptable for use on
emergency police or fire alarm boxes.
ɀ Same size as G24 series glass globes.
Existing installations can be changed to
plastic globes simply by replacing globe.
ɀ For use with 200 watt series luminaires
such as VDA22, etc.
ɀ For use without guard.
Max. Wattage,
Color
Lamp Size
Cat. #
Natural
200 watt, A-23
G63 Green
200 watt, A-23
G65
Red
200 watt, A-23
G67
Note: Polycarbonate globes for nonhazardous locations only.
Mounting Adapter Kit
ɀ Allows for the mounting of non-CrouseHinds outlet boxes to the VXT20 wall mount
bracket and VXH ceiling mount bracket
Cat. #
VXT-K1
VXFT – 5 Hubs, 4 Plugs
Hub
Size
Cat. #
1⁄2
VXFT10
3⁄4
VXFT20
For use when rear wiring entry is required.
Use in lieu of VXF10 or VXF20.
VXT-K1
ɍ G24 is available with a TEFLON coating for increased shatter protection by
adding suffix S808.
* With G55, G56, G57, G58 color globes, maximum lamp size is 60 watt for outdoor
applications.
** Prior to wash-down, globes must be cool.
† All glass globes are configured type, having fluted side and stippled bottom.
‡ Globe G251 required when guard P22 is used. Use globe G34 when guard is not
used.
1 Lamp must be mounted in vertical position base up to 45°C (stanchion) only.
®
– available with Lightning Service TM
See Section G for complete details
696
STIBOINFO((CRH:66008com:1L:696))
CH0 0 1 L - 7
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0697-9 Name: 1L-697
100:
DATE: JAN 19 2006
Time: 5:44:32 PM Operator: RB
VAPORGARD TM Series
Incandescent
Luminaires
COLOR: CMYK
TCP: 15001
Family Tree
Typedriver Name: TS name csm no.: 100
1L
– available with Lightning Service TMSee Section G for complete details
US: 1-866-764-5454
STIBOINFO((CRH:66008com:1L:697))
CH0 1 L - 1 5
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
697
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0698-1 Name: 1L-698
1L
100:
DATE: JAN 19 2006
Time: 5:44:33 PM Operator: JB
VAPORGARD TM Incandescent
Luminaires
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
Photometric Data
Luminaire With Globe, 30° Angle Reflector and With
or Without Guard
Luminaire VXHA45GPRA
Lamp: 150W/A-21
Total Bare Lamp Lumens: 2850
Total
Lumens Eff. %
With
Guard
1490
52.3
Without
Guard
1881
66.0
Lamp: 100W/A-21 through 200W/A-23
Total Bare Lamp Lumens: 4000
NOTE: All data provided is for 200W/A-23 incandescent lamp. Use
following candlepower/lumen multipliers for other lamp sizes:
100W 0.42; 150W 0.7
Measurements taken from A-A′ plane.
Measurements taken from A-A′ plane.
Luminaire VXHA42GPRA
Lamp: 300W/PS-30
Total Bare Lamp Lumens: 6300
Total
Lumens Eff. %
With
Guard
Without
Guard
3630
57.6
4271
67.8
Lamp
Size
100W
150W
200W/A-23
200W/PS-25
Without Guard
Total
Lumens Eff. %
1141
1890
2700
67.5
2174
With Guard
Total
Lumens Eff. %
949
1582
2260
56.5
1819
Luminaire With Globe, 30° Angle Reflector and With
or Without Guard
Lamp: 300W/PS-30
Total Bare Lamp Lumens: 6000
Total
Lumens Eff. %
With
Guard
Without
Guard
Measurements taken from A-A′ plane.
Measurements taken from A-A′ plane.
698
STIBOINFO((CRH:66008com:1L:698))
CH0 0 1 L - 8
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
3360
56.0
3954
65.9
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0699-2 Name: 1L-699
DATE: JAN 19 2006
Time: 5:44:34 PM Operator: RB
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
Photometric Data
VAPORGARD TM Incandescent
Luminaires
1L
Lamp: 100W/A-21 through 200W/PS-25
Total Bare Lamp Lumens: 4000
To determine number and placement of luminaires see Lighting Selector Guide, pages 665 to
689.
NOTE: All data provided is for 200W/A-23 incandescent lamp. Use following candela/lumen
multipliers for other lamp sizes: 100W 0.42;
150W 0.7;
200W/PS-25 0.82
Luminaire With Globe and With or
Without Guard
Luminaire With Globe, Dome Reflector and With
or Without Guard
Example: Zonal Lumens for
200W/A-23 lamp with guard
for 0-40° is 272 Zonal
Lumens for 150W lamp with
guard for 0-40° is 272 × 0.7
⍧ 190.
Coefficient of Utilization
Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil. Wall
1
2
3
50
.654
.549
.471
80
30
.608
.486
.400
10
.567
.432
.345
50
.603
.506
.434
70
30
.563
.449
.370
10
.523
.401
.320
50
.509
.424
.363
50
30
.477
.380
.313
10
.449
.341
.271
50
.422
.349
.297
30
30
.399
.315
.259
10
.376
.285
.225
50
.343
.280
.237
10
30
.324
.253
.206
10
.307
.230
.180
4
.407
.333
.277
.375
.309
.257
.312
.260
.218
.255
.214
.180
.202
.170
.143
5
.353
.282
.228
.326
.260
.211
.273
.220
.179
.223
.180
.147
.176
.142
.115
Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil. Wall
1
2
3
50
.604
.522
.454
80
30
.576
.480
.404
10
.552
.444
.364
50
.591
.512
.445
70
30
.565
.472
.398
10
.543
.440
.361
50
.564
.490
.428
50
30
.544
.457
.387
10
.526
.428
.354
50
.541
.470
.411
30
30
.525
.444
.377
10
.509
.419
.348
50
.521
.452
.396
10
30
.507
.429
.367
10
.494
.409
.342
4
.395
.340
.298
.387
.336
.296
.372
.327
.292
.358
.319
.288
.345
.311
.283
5
.347
.290
.248
.339
.286
.246
.327
.280
.245
.315
.273
.241
.304
.268
.238
% Reflectance
Eff Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
9
.226
.162
.118
.208
.150
.110
.175
.126
.092
.143
.103
.075
.114
.080
.057
10
.201
.140
.100
.185
.130
.093
.156
.109
.077
.128
.088
.061
.101
.068
.045
Reflectance
Eff Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
9
.222
.170
.135
.219
.168
.135
.211
.166
.134
.204
.162
.133
.198
.159
.131
10
.193
.142
.110
.189
.142
.110
.184
.139
.109
.178
.136
.107
.173
.134
.106
Room Cavity Ratio
6
7
8
.315
.279
.249
.244
.210
.183
.193
.164
.137
.289
.257
.230
.225
.194
.170
.177
.150
.127
.242
.215
.192
.189
.163
.143
.150
.126
.106
.198
.175
.158
.155
.134
.116
.123
.102
.086
.157
.140
.124
.122
.106
.091
.096
.080
.066
US: 1-866-764-5454
STIBOINFO((CRH:66008com:1L:699))
CH0 0 1 L - 9
Example: Zonal Lumens for
200W/A-23 lamp with guard
for 0-40° is 948 Zonal
Lumens for 150W lamp with
guard for 0-40° is 948 × 0.7
⍧ 664.
CAN: 1-800-265-0502
Room Cavity Ratio
6
7
8
.309
.274
.244
.253
.220
.192
.214
.184
.155
.303
.270
.241
.250
.217
.191
.211
.181
.154
.291
.260
.232
.245
.212
.186
.209
.179
.153
.281
.250
.225
.239
.209
.182
.207
.177
.152
.272
.243
.217
.234
.205
.179
.205
.175
.150
Copyright© 2006 Cooper Crouse-Hinds
699
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0700-2 Name: 1L-700
1L
DATE: JAN 19 2006
Time: 5:44:35 PM Operator: RB
VAPORGARD TM Incandescent
Luminaires
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
Photometric Data
Lamp: 300W/PS-30
Total Bare Lamp Lumens: 6000
To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to
689.
Luminaire With Globe Only
Luminaire With Globe and Dome Reflector
Coefficient of Utilization
Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil. Wall
1
2
3
50
.692
.582
.499
80
30
.644
.515
.425
10
.602
.459
.367
50
.636
.534
.458
70
30
.594
.475
.392
10
.552
.425
.339
50
.532
.444
.380
50
30
.500
.398
.328
10
.470
.358
.285
50
.437
.362
.308
30
30
.412
.326
.268
10
.389
.295
.234
50
.350
.285
.241
10
30
.331
.258
.210
10
.313
.235
.183
4
.431
.354
.295
.396
.327
.273
.327
.272
.229
.264
.222
.186
.205
.172
.145
5
.373
.300
.243
.345
.276
.223
.286
.230
.188
.230
.186
.152
.179
.144
.116
Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil. Wall
1
2
3
50
.766
.671
.587
80
30
.734
.621
.528
10
.706
.579
.482
50
.750
.657
.577
70
30
.720
.610
.521
10
.694
.573
.477
50
.717
.630
.555
50
30
.693
.592
.507
10
.672
.558
.468
50
.688
.606
.535
30
30
.670
.575
.494
10
.651
.546
.460
50
.663
.584
.516
10
30
.647
.557
.482
10
.632
.534
.452
4
.514
.448
.398
.505
.444
.395
.485
.432
.390
.468
.422
.385
.452
.412
.379
5
.454
.385
.334
.443
.380
.332
.429
.372
.329
.414
.364
.325
.400
.357
.321
% Reflectance
Eff Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
9
.238
.170
.125
.219
.157
.115
.181
.131
.095
.146
.105
.075
.114
.080
.055
10
.212
.147
.105
.194
.136
.097
.162
.113
.079
.130
.090
.061
.101
.067
.044
% Reflectance
Eff Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
9
.293
.229
.185
.288
.227
.185
.279
.223
.184
.270
.218
.182
.262
.215
.180
10
.254
.191
.151
.249
.191
.151
.243
.187
.150
.235
.184
.148
.229
.181
.146
700
STIBOINFO((CRH:66008com:1L:700))
CH0 1 L - 1 0
Room Cavity Ratio
6
7
8
.333
.295
.263
.258
.223
.194
.205
.173
.145
.305
.271
.241
.238
.204
.178
.188
.158
.133
.253
.224
.200
.198
.170
.148
.157
.132
.110
.204
.180
.162
.160
.138
.119
.127
.105
.088
.158
.141
.124
.123
.106
.091
.096
.079
.066
US: 1-866-764-5454
CAN: 1-800-265-0502
Room Cavity Ratio
6
7
8
.404
.360
.322
.337
.294
.258
.289
.250
.212
.397
.354
.317
.333
.290
.256
.285
.246
.211
.383
.342
.306
.326
.284
.250
.283
.244
.209
.371
.330
.297
.320
.280
.245
.281
.241
.208
.359
.322
.288
.313
.275
.241
.277
.239
.206
Copyright© 2006 Cooper Crouse-Hinds
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0701-1 Name: 1L-701
100:
DATE: JAN 19 2006
Time: 5:44:36 PM Operator: JB
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
VAPORGARD TM Incandescent
Luminaires
1L
Dimensions
a
b
c
d
e
f
g
h
j
150 watt,
A-21
127⁄8
111⁄8
53⁄8
313⁄16
87⁄16
12
813⁄16
9
41⁄2
200 watt,
PS-25
167⁄8
145⁄8
6
4
91⁄8
14
101⁄2
1013⁄16
611⁄16
300 watt,
PS-30
167⁄8
145⁄8
6
4
91⁄8
14
12
131⁄8
611⁄16
VDA Series
VDC Series
VXH and VXHF Series
(omit box for VXF Series)
VXHT and VXHBF Series
(NOTE: Omit box for VXHB series)
Max. Lamp Size
150 watt, A-21
a
53⁄8
200 watt, A-23, A-25, PS-25
and 300 watt, PS-30
6
US: 1-866-764-5454
STIBOINFO((CRH:66008com:1L:701))
CH0 1 L - 1 1
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
701
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0702-2 Name: 1L-702
DATE: JAN 19 2006
Time: 5:44:37 PM Operator: RB
V-Series Incandescent
Luminaires
1L
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
Wet Locations
NEMA 3,3R
Enclosed and Gasketed
Application:
Standard Materials:
V-Series incandescent luminaires are used:
ɀ indoors or outdoors in industrial locations
where enclosed and gasketed fixtures are
required
ɀ in tunnels, building entrances and similar
locations, where moisture, dirt, chemicals,
vibration or rough usage are a problem
ɀ for flush or surface mounting on ceiling or
wall, with or without a cast outlet box,
pendant or in conduit systems
ɀ Bodies – Feraloy® iron alloy
ɀ Guards – copper-free aluminum
ɀ Globes – glass
ɀ Reflectors – Krydon® fiberglass-reinforced
polyester material reflectors
Certifications and
Compliances:
ɀ Wet locations
ɀ NEMA: 3, 3R
ɀ UL Standard: 1598
Standard Finishes:
ɀ Feraloy iron alloy – electrogalvanized and
aluminum acrylic paint
ɀ Copper-free aluminum – natural
ɀ Krydon® material – high reflectance white
Features:
ɀ Designed to exclude dirt, moisture and
corrosive vapors from the interior of the
fixtures and the conduit system.
ɀ Several body styles provide a wide variety
of mountings, while all use the same globes,
guards and optional accessories.
ɀ Rugged and corrosion resistant.
Size Ranges:
ɀ 3⁄4 hubs
ɀ Maximum wattage lamp:
- Glass globes 150W, A23
- Polycarbonate 75W, A33
Options:
Description
Corro-free TM epoxy
powder coat
Suffix
S752
plastic polycarbonate
globe
Order separately.
See below
VDA
VC
VG
VJ
VD
Description
With plain globe
and guard
Cat. #
VDA2759
Cat. #
VC2759
Cat. #
VG2759
Cat. #
VJ2759
Cat. #
VD2759
Without globe and
guard
VDA275
VC275
VG275
VJ275
VD275
Glass Globes
Guard For
Glass Globes
Polycarbonate Globes
Application:
Polycarbonate globes are used:
ɀ in food processing plants, canneries,
dairies, breweries and bakeries
ɀ in emergency lighting
ɀ emergency police and fire alarm boxes
Features:
ɀ Polycarbonate globes are shatterproof,
preclude contamination of food products
with broken particles of glass.
ɀ Comply with U.S. Dept. of Agriculture
specification for food processing plants.
V63
Color
Clear (heat
resisting)
Green
Blue
Red
Amber
702
STIBOINFO((CRH:66008com:1L:702))
CH0 1 L - 1 2
Cat. #
V63
VN72
VN73
VN75
VN76
V911
Globe
Size
63⁄4⍯
Cat. #
V911
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
V470
Color
Natural
Red
Cat. #
V470
V475
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0703-3 Name: 1L-703
DATE: JAN 19 2006
Time: 5:44:39 PM Operator: RB
COLOR: CMYK
TCP: 15001
Incandescent Luminaires
Typedriver Name: TS name csm no.: 100
1L
Accessories and Parts For V-Series
Dome
Receptacles (medium base)
Cat. #
V46
Angle
Gasket
Cat. #
GASK213
Reflectors
Krydon® – fiberglass-reinforced polyester
(Must be used with V 911 Guard)
Lamp
Size
50-150W
Lamp
Size
50-150W
Dome
Dia.
Cat. #
12⍯
RD60
30° Angle
Dia.
Cat. #
12⍯
RA60
NOTE: Angle reflector cannot always be used
with bracket style fixtures. Check distance
from mounting surface to center of body
against reflector size to determine if reflector
will fit.
US: 1-866-764-5454
STIBOINFO((CRH:66008com:1L:703))
CH0 1 L - 1 0
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
703
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0704-1 Name: 1L-704
100:
DATE: JAN 19 2006
Time: 5:44:40 PM Operator: JB
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
V-Series Incandescent
Luminaires
1L
Enclosed and Gasketed
Dimensions
VC
Hub
Size
1⁄2
3⁄4
VDA
a
7⁄8
7⁄8
c
311⁄16
311⁄16
d
4
4
h
63⁄16
63⁄16
VD
k
49⁄16
49⁄16
VG
Hub
Size
1⁄2
3⁄4
a
415⁄16
415⁄16
b
43⁄16
43⁄16
c
515⁄16
63⁄16
g
21⁄2
23⁄4
h
63⁄16
63⁄16
k
49⁄16
49⁄16
b
113⁄16
115⁄16
c
47⁄8
47⁄8
d
3⁄8
e
53⁄8
53⁄8
h
63⁄16
63⁄16
k
49⁄16
49⁄16
VJ
c
47⁄8
47⁄8
704
STIBOINFO((CRH:66008com:1L:704))
CH0 1 L - 1 6
Hub
Size
1⁄2
3⁄4
h
63⁄16
63⁄16
Hub
Size
1⁄2
3⁄4
k
49⁄16
49⁄16
US: 1-866-764-5454
CAN: 1-800-265-0502
3⁄8
Copyright© 2006 Cooper Crouse-Hinds
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0705-2 Name: 1L-705
DATE: JAN 19 2006
Time: 5:44:41 PM Operator: RB
COLOR: CMYK
TCP: 15001
Photometric Data
V-Series Incandescent
Luminaires
Typedriver Name: TS name csm no.: 100
1L
Enclosed and Gasketed
Luminaires V-Series
Lamp: 150W/A23 Clear
Total Bare Lamp Lumens: 2800
To determine number and placement of fixtures, see Lighting Selector
Guide pages 665 to 689.
Zonal Lumens
NOTE: All data provided is
Without With
for 150W incandescent
Zone Guard Guard
lamp. Use following
0-10
29
19
10-20
67
60
candela/lumen multipliers
20-30
109
60
for the other lamp sizes:
30-40
127
113
40-50
175
168
100W – 0.61
50-60
218
117
60-70
246
250
Example: Zonal lumens
70-80
228
232
80-90
223
65
for 150W lamp for 0-40°
90-100 209
218
with guard is 252.
100-110 210
218
110-120 210
120-130 194
130-140 164
140-150
87
150-160
3
Total
2499
216
72
165
58
8
2039
Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceil.
Wall
50
80
30
10
Room Cavity Ratio
1
2
3
.659
.558
.479
.623
.504
.417
.591
.458
.367
4
.416
.349
.298
5
.361
.298
.248
70
50
30
10
.609
.577
.545
.515
.466
.426
.442
.386
.342
.384
.324
.278
.336
.275
.230
50
50
30
10
.515
.491
.469
.434
.397
.364
.372
.328
.293
.321
.274
.238
.282
.234
.197
30
50
30
10
.429
.411
.395
.359
.332
.307
.307
.274
.245
.264
.228
.198
.232
.194
.165
10
50
30
10
.350
.337
.325
.290
.269
.251
.246
.221
.199
.211
.183
.160
.185
.156
.132
Room Cavity Ratio
6
7
8
.325
.290
.261
.259
.227
.199
.212
.183
.157
9
.236
.176
.136
10
.211
.153
.116
% Reflectance
Eff. Ceil.
Wall
50
80
30
10
70
50
30
10
.299
.240
.197
.268
.210
.170
.241
.186
.146
.219
.164
.127
.194
.143
.108
50
50
30
10
.252
.205
.169
.226
.178
.145
.203
.158
.125
.185
.140
.109
.165
.122
.092
30
50
30
10
.208
.170
.141
.186
.149
.121
.169
.131
.105
.153
.117
.091
.137
.101
.076
10
50
30
10
.167
.136
.114
.151
.121
.098
.135
.106
.084
.124
.094
.073
.110
.081
.060
US: 1-866-764-5454
STIBOINFO((CRH:66008com:1L:705))
CH0 1 L - 1 7
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
705
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0706-1 Name: 1L-706
1L
DATE: JAN 19 2006
Time: 5:44:42 PM Operator: JB
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
Cl. I, Div. 2, Groups A,B,C,D
Corrosive
Wet Locations
NEMA 3,3R,4,4X
NDA CorroɀGard TM CorrosionResistant Incandescent
Luminaires
NDA Series Ordering
Information
Application:
CorroɀGard TM NDA series Luminaires made
of Krydon® fiberglass-reinforced polyester are
used to provide incandescent lighting:
ɀ indoors or outdoors in industrial wet or dirty
locations and where corrosion is a problem
ɀ in marine applications, above and below
deck, where salt spray corrosion shortens
fixture life
ɀ in food and beverage industries where
frequent wash-downs are necessary
ɀ for walkways, bridges, tunnels, security
lighting, cold storage facilities, garages, coal
handling areas, shipboard, processing
plants, and nuclear generating plant
containment areas
For Pendant Mounting
Hub
Size
3⁄4⍯
Max.
Lamp
Size
300W
PS-25
Med.
Base
120V
Body
Only
Cat. #
NDA22
Globe
Only
Cat. #
G24
Temperature Performance Data:
Features:
ɀ Luminaire is molded Krydon for excellent
corrosion, heat, and impact resistance.
ɀ Accommodates all popular incandescent
lamps up to 300W, PS-25.
ɀ Attractive modern design and color
complement other CorroɀGard products.
ɀ Weighs only 81⁄2 lbs. complete with lamp
and globe.
ɀ Medium screw base porcelain lamp socket
has a vibration absorbing mounting bracket.
ɀ All joints are gasketed to ensure
watertightness.
ɀ Configured glass globe reduces glare.
ɀ CorroɀGard reflectors made of Krydon®
reflect light better than porcelainized steel; do
not yellow or discolor with age; cannot chip,
peel, rust or dent.
®
Certifications and
Compliances:
ɀ UL Standard: 1598
ɀ Wet Locations
ɀ Suitable for 40°C ambient temperature
(based on 40°C ambient)
Max.
Lamp
Size
T-Number
300W
T2A
(Note: Fixtures are not marked with T-Number.)
Dimensions
Standard Materials:
ɀ Bodies and reflectors – Krydon® fiberglassreinforced polyester material
ɀ Globes – configured heat-resistant glass
Standard Finishes:
ɀ Bodies – natural
ɀ Reflectors – natural, high reflectance white
Options:
ɀ TEFLON® coating on G24 globe for
increased shatter protection. . . . . . . add suffix
S808.
Accessories & Parts
Globe
Replacement Lamp
Receptacles with Strap
Reflectors
(Order separately)
Shock Absorbing
Guard
Dome
Cat No. NV84
Color
Clear (heat resisting)
Green
Blue
Red
Amber
706
STIBOINFO((CRH:66008com:1L:706))
CH0 1 L - 2 0
Body
With
Globe‡
Cat. #
NDA22G
Cat. #
G24
G25
G26
G27
G28
Cat. #
P21
30° Angle
Type
Dome
30° Angle
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
Cat. #
RD725 (RD75)
RA725 (RA75)
Supply
Wire (°C)
150°C
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
100:
JOB: CRMAIN06-0707-2 Name: 1L-707
DATE: JAN 19 2006
Time: 5:44:43 PM Operator: RB
COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
Photometric Data
NDA CorroɀGard TM CorrosionResistant Incandescent
Luminaires
1L
Lamp: 200W/PS-25
To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to
689.
NOTE: All data provided is for incandescent with 200W/PS-25 lamp. See Multipliers for other
wattages and lamp types.
Luminaire With Globe
Luminaire With Globe and
Dome Reflector
Coefficient of Utilization
Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance Room Cavity Ratio
Eff. Ceil.Wall 1
2
3
4
50
.762 .651 .565 .494
80
30
.715 .585 .491 .416
10
.673 .529 .433 .357
Effective Floor Cavity Reflectance 20%
% Reflectance Room Cavity Ratio
Eff. Ceil.Wall 1
2
3
4
50
.809 .703 .615 .541
80
30
.773 .647 .550 .470
10
.742 .601 .499 .416
5
.433
.358
.300
CANDLES AT 25 FT. IN PLANE
A-A’ WITHOUT GUARD
DEGREES FRONT BACK
0
630
5
646
619
10
672
577
15
677
539
20
677
498
25
677
465
30
677
422
35
677
388
40
640
338
45
630
278
50
630
89
55
625
24
60
583
5
65
551
70
525
75
461
80
422
85
385
90
346
95
310
100
273
105
207
110
68
115
24
120
5
125
130
5
.481
.408
.354
Total
Lumens
2595
Eff. %
80.6
70
50
30
10
.708
.667
.626
.605
.546
.496
.526
.460
.407
.461
.390
.336
.406
.335
.282
70
50
30
10
.791
.758
.729
.688
.636
.595
.604
.542
.494
.531
.465
.413
.470
.403
.315
50
50
30
10
.608
.576
.547
.519
.473
.432
.452
.399
.356
.395
.339
.295
.292
.250
.248
50
50
30
10
.756
.729
.706
.659
.617
.579
.580
.528
.485
.510
.453
.408
.455
.395
.349
Multipliers for Other Lamps
30
50
30
10
.516
.492
.469
.439
.404
.372
.382
.342
.307
.335
.290
.254
.297
.250
.215
30
50
30
10
.726
.705
.684
.634
.599
.566
.558
.514
.477
.492
.442
.402
.439
.385
.344
Photometric data was developed using a 200
watt/PS-25 inside frosted incandescent lamp (3,220
lumens). For other incandescent watts/lamp size,
use the following conversion factors (multipliers):
10
50
30
10
.433
.413
.396
.366
.339
.315
.319
.287
.259
.279
.244
.215
.247
.211
.181
10
50
30
10
.699
.663
.580
.610
.580
.553
.539
.501
.468
.475
.431
.396
.424
.378
.340
0
0
.354
.277
.226
.184
.154
0
0
.647
.536
.451
% Reflectance
Eff. Ceil.Wall
50
80
30
10
.378
.323
Room Cavity Ratio
6
7
8
.431 .386 .347
.360 .317 .280
.309 .269 .231
9
.317
.250
.204
10
.277
.211
.169
70
50
30
10
.423
.356
.305
.380
.312
.265
.342
.277
.231
.312
.247
.204
.272
.211
.169
.205
.153
.117
50
50
30
10
.408
.348
.303
.368
.305
.263
.331
.272
.229
.302
.243
.202
.265
.207
.167
.197
.152
.121
.175
.131
.100
30
50
30
10
.396
.342
.300
.355
.301
.260
.321
.266
.227
.294
.238
.201
.257
.203
.165
.180
.144
.116
.166
.129
.102
.147
.110
.084
10
50
30
10
.383
.334
.297
.346
.295
.258
.311
.262
.225
.285
.235
.199
.250
.200
.163
.096
.084
.068
0
0
.281
.243
.210
.184
.150
Room Cavity Ratio
6
7
8
.389 .348 .312
.312 .273 .240
.258 .222 .190
9
.284
.214
.166
10
.253
.185
.141
70
50
30
10
.363
.293
.242
.324
.256
.208
.291
.226
.179
.266
.201
.157
.236
.175
.133
50
50
30
10
.312
.256
.213
.280
.223
.183
.252
.198
.158
.230
.177
.139
30
50
30
10
.266
.220
.185
.238
.193
.158
.216
.170
.137
10
50
30
10
.223
.185
.156
.201
.163
.135
0
0
.132
.112
% Reflectance
Eff. Ceil.Wall
50
80
30
10
US: 1-866-764-5454
STIBOINFO((CRH:66008com:1L:707))
CH0 1 L - 1 5
Luminaire With Globe and
30° Angle Reflector
CAN: 1-800-265-0502
Watts
100
100
Lamp Size
A-19
A-21
Lamp
Lumens
1750
1690
Conversion
Factor
.54
.52
150
150
A-21
PS-25
2880
2680
.89
.83
200
A-23
4010
1.25
300
PS-25
6360
1.98
Example: Zonal lumens for 200W/PS-25 luminaire
with globe and dome reflector for 30-40° is 389.
Zonal lumens for 100W/A-21 luminaire with globe
and dome reflector for 30-40° is 389 × .52 ⍧ 202.
Copyright© 2006 Cooper Crouse-Hinds
707
Zoom: 100
Download