QUADRA
EXTERIOR - PATHWAY & STEP LIGHTING
WHITE LIGHT & STATIC COLORS
SHAPING THE EXPERIENCE OF LIGHT
Unshielded
Optional White Translucent Lens
Optional Visor
Optional Louver
SPECIFICATION
OPTICS
ASYMMETRIC
LED COLOR/CCT
2700K, 3000K, 3500K, 4000K, static red, static green, static blue, static amber
Color temperature conforms to ANSI C78 377A
4000K, 39" Fixture
OUTPUT
LUMENS & EFFICACY
ELECTRICAL
PHYSICAL
WATTAGE
LUMENS
EFFICACY (lm/W)
12W
600 lm
16.5 lm/W
LUMEN MAINTENANCE
L70 AT 25° C, MINIMUM 75,000 HOURS
POWER SUPPLY
Integral within the fixture housing
INPUT VOLTAGE
120V to 277V
AMBIENT TEMPERATURE
Rated for use in ambient temperatures from -30° C (-22° F) not to exceed 35°C (95°F).
HOUSING
A recessed rough-in box, constructed of extruded aluminum and die cast end caps
A temporary cover is factory installed on the rough-in box which can be pre-shipped for installation
Powder-coat painted finish
LENS
Unshielded, clear tempered glass lenses are standard for white light
Optional White Translucent (WL) lenses are suitable for direct view applications
CERTIFICATION
ETL and cETL approved for Wet Location
RoHS
COMPLIANT
WARRANTY
5 YEAR
Limited
Lumen measurement tested in accordance with IES LM-79-08
QD
O R D ERING INFORM ATION
Prefix
Wattage
Watts /Ft
LED
Color/CCT
QD
6
QUADRA
SERIES
12
27K = 2700K
30K = 3000K
35K = 3500K
40K = 4000K
R = Red
G = Green
B = Blue
A = Amber
Mounting
Fixture
Length
SW = Stud Wall
15"
BW = Brick Wall
27"
CW = Concrete Wall
39"
Voltage/
Wiring Method
INT1 = 120V Integral
Power Supply
INT2 = 277V Integral
Power Supply
Finish
Options
TW = Textured White
LV = Louver
TBL = Textured Black
VS = Visor
TBR = Textured Bronze
WL = White Translucent Lens
(Suitable for direct view applications)
TLB = Textured Light Bronze
TN = Textured Natural
TS = Textured Sandstone
CC = Custom Color


Contact factory. Additional
charges may apply.
CRF = Corrosion Resistant Finish
Corrosion resistant finish is recommended
for coastal or extreme exterior
environments
Thru-Wiring is available. Contact factory
for details.
Please contact factory for controls and
programming assistance.
Insight Lighting
www.insightlighting.com
August 1, 2016
1 of 4
QUADRA
EXTERIOR - PATHWAY & STEP LIGHTING
WHITE LIGHT & STATIC COLORS
SHAPING THE EXPERIENCE OF LIGHT
3
48"
Standard
Unshielded
5"
"B"
1-1/2"
LUMINOUS
APERTURE
OPENING
UNSHIELDED
6"
5
8"
7
38"
"A"
"C"
Optional
Louver (LVR)
"B"
5"
5
18"
LUMINOUS
APERTURE
OPENING
W/ LVR
6"
5"
3
4"
3
34"
"A"
3
48"
"C"
3
18"
73°
1"
Optional
Visor (VS)
3
54"
5"
"B"
1
14"
6"
7
38"
5
8"
5
8"
LUMINOUS
APERTURE
OPENING
W/ VISOR
"A"
3
48"
"C"
7
18"
Nominal Fixture Length
Dim. "A"
Dim. "B"
Dim. "C"
15"
15-7/8"
11-5/8"
15"
27"
27-7/8"
23-5/8"
27"
39"
39-7/8"
35-5/8"
39"
3
18"
Insight Lighting
www.insightlighting.com
August 1, 2016
2 of 4
QUADRA
EXTERIOR - PATHWAY & STEP LIGHTING
WHITE LIGHT & STATIC COLORS
SHAPING THE EXPERIENCE OF LIGHT
Plaster
Sheathing
Face Plate
2X 1/2" NPT
Holes
Stucco Stop
4X Luminaire
Mounting Brackets
STUD WALL MOUNT
2" X 6"
Brick Face
Sheathing
Face Plate
2X Luminaire
Mounting Brackets
2X 1/2" NPT
Holes
BRICK WALL MOUNT
Concrete
Face Plate
2X Luminaire
Mounting Brackets
2X 1/2" NPT
Holes
CONCRETE WALL MOUNT
Insight Lighting
www.insightlighting.com
August 1, 2016
3 of 4
QUADRA
EXTERIOR - PATHWAY & STEP LIGHTING
WHITE LIGHT & STATIC COLORS
SHAPING THE EXPERIENCE OF LIGHT
QUADRA POLAR CURVE
QD/12/40/SW/39/1/X
Quadra 39" Fixture, 12W/Ft., 40K
Total Lumen Output = 600 Lumens
Luminarire Efficacy = 16.5 Lumens/Watt