Presentation Bender engl [Schreibgeschützt]

advertisement
The Bender Group
Overview
Feb 2011
©
Over 70 years of experience in Insulation Monitoring
©
Based on 70 Years of Success
Who we are
Vision
Mission
Our Vision
Values
The power behind electrical systems. We make electrical power safe.
Our Mission
We are providing the most advanced products and systems to protect
people, processes and assets against the hazards of electrical power.
Around the globe, customers prefer our innovative technology, making us
the fastest growing company in our industry.
Our Values
We care about the environment. We take social responsibility for our
employees and in the regions we are operating in. We do business in full
accordance with the highest legal and ethical standards.
©
The Bender Group today
Where we are today
Global specialist for electrical safety
Familiy owned enterprise in the third generation
Headquarters in Grünberg, Hessen, Germany
Production site in Siersleben,
Sachsen-Anhalt, Germany
Over 500 employees in 14 countries
- 9 countries in Europe
- 5 countries in other continents
- Over 60 global partner
4
©
Global Footprint
5
©
BENDER Group Product Portfolio
Monitoring Isolated Systems
(MIS)
A-ISOMETER®
Insulation monitoring
devices (IMD) and Line Isolation
Monitoring devices (LIM)
Monitoring Earthed Systems
(MTS)
Residual Current Monitors RCM,
RCMA
Gateways
Residual Current Monitoring
Systems (RCMS)
Monitoring visualization
Special purpose IMDs for
Photovoltaic applications
RCM Modules for photovoltaic or
vehicle charger applications.
Automotive IMD
Measuring and Monitoring Relays
for electrical quantities (V, I, f,
earth, phase..)
Insulations fault location devices
Ground fault relays
Coupling devices up to 15kV
System and Communication
Technology (SCT)
Current Transformers
Isolation-Transformers
6
Indicator and operator panels
Residual Current Monitoring
Systems (RCMS)
ATiCS®
Switchover and
monitoring modules
UNIMET®
Test systems for
electrical safety.
©
Solutions for special requirements
Area of application
Transportation
Airports, aerospace industry, industrial, residential and
functional buildings, railway, ships, construction, offshore,
cranes, infrastructure
Energy Generation /Distribution
Power plants, photovoltaics, main circuits and control
circuits, control and switchgear cabinet construction
Service Providers
Banks, insurance companies, computer centers, film and
television technique, fixed network and mobile telephony
operators, planners,
engineering offices, testing agencies
7
©
Solutions for special requirements
Area of application
Process- / Primary Industry
Chemicals, steel, mining, glass, food, oil, gas, water, paper,
pharma-ceuticals, cement, timber
Medical Locations
Hospitals, operating centers, sanatoriums, health clinics,
medical centers
Process Industry
Automotive, machine construction, semiconductors,
electronics, automation, welding robots
8
©
Electrical Safety in Automotive
Development
Crash Tests
Production
Tracking of HV net
quality
Diagnosis
Secure car access
HV cut off at low Riso
Detect faulty parts &
connections
HV measurement with
production tools
In operation
Service
Insulation Monitoring
Tracking of HV net
quality
Maintanance
HV test
HV fault location
…solutions for Automotive
Roadside Service
Accidence
Charging
Diagnosis
Secure car access
HV cut off
Safe charging
No influence of
internal and external
IMD
9
©
BENDER Products
1. IR155
On-Board IMD
2-channel output for status & data
Up to 1.000 V DC
Measurement range: 0 – 10MΩ; CAbl ≤ 1µF
Meets SEA J 2344 and ISO 6469 requirements
< 2s response time for good/bad Riso trend
17.5..20s response time for accurate DCP value
2. EDS190
Insulation Fault
Location System
“EDS190” functionality to support fault location
High voltage test port (Voltage, Current)
Different clamps for special requirements in
vehicles
Optional portable Pulse generator for systems w/o
integrated Pulse generators
10
©
BENDER Products
3. RCMB101
Charging Station
RCM Level 1 & 2
CCID20 Unit
Charging point RCM type B sensor
Grounded system AC/DC residual current
measurement.
Range 0..100mA / 0..500Hz, 2mA resolution.
AC/DC fault detection.
4. IR155-3410 Charging Station
IMD
2-channel interface for status & data
Up to 800 V AC/DC
Meets SAE J 1772 and UL2231 requirements
Measurement range: 0 – 10MΩ; CAbl ≤ 1µF
< 2s response time for good/bad Riso trend
<10s response time for accurate AMP value
Share hardware platform with IR155-3403/04
11
©
Imprint
Dipl.-Ing. W. Bender GmbH & Co.KG
Londorfer Straße 65
35305 Grünberg
www.bender-de.com
Telephone: +49 6401 807-0
Fax:
+49 6401 807-259
E-mail:
info@bender-de.com
Fotos: Bender Archiv; www.pixelio.de, www.fotolia.com
Bender GmbH & Co. KG · 35305 Grünberg · Germany · www.bender-de.com · FO1Bender_D
12
·
Änderungen vorbehalten
©
Download