Product family LV HRC fuse switch-disconnectors The “9” series LV HRC fuse switch-disconnectors of the DIN sizes 00-4a are suitable for surface mounting on mounting plates and for direct mounting on busbars. The different sizes are available as 1-pole, 2-pole, 3-pole and 4-pole versions. 11-0 • Surface mounting • Busbar mounting • 1-pole, 2-pole, 3-pole and 4-pole • Retrofittable cable connections • Fuse monitor • Position indication • DIN rail fixing parts Product group Product type 1-pole / surface mounting Sizes 00 - 4a Accessories Page 11-04 11-06 LVHRC fuselinks 2-pole / surface mounting Sizes 00 - 3 Accessories 11-10 11-12 HVHRC fuselinks 3-pole / surface mounting Sizes 00 - 4a Accessories 11-14 11-16 4-pole / surface mounting Sizes 00 - 3 Accessories 11-20 11-22 1-pole / busbar mounting Sizes 00 - 3 Accessories 11-26 11-28 3-pole / busbar mounting Sizes 00 - 3 Accessories 11-30 11-32 Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Drawings 11-35 Technical data 11-58 Terminals LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchrs on disc necto Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-1 Appendix LV HRC fuse switch-disconnectors, size 1 Example: Surface mounting with accessories, 1-pole Basic construction 4 1 Base of disconnector U-LTL1-1 2 Protective cover, top BO-LTL1-1 3 Protective cover, bottom BU-LTL1-1 4 Swing-in device D-LTL1-1/9 11b) 9 Connection accessories 5ab) Screw terminal F-LTL1-M10 6 Clamp-type terminal S1 7 V terminal clamp P1 8 Double V-terminal clamp P12 9 10b) Covering accessories (Protection against contact) 3 9 2 11a) Handle protection, top and bottom GOU-LTL1-1 Accessories for mechanical fuse monitoring Position indicator, “ON” 12 10a) 8 7 6 10ab) Mech. fuse monitor K-LTL1-1/H 11ab) Position indicator, “ON” (electrical interlocking) eV-LTL123-1 5a) LV HRC fuse switch-disconnectors with quasi-instantaneous circuit 5b) 1 11-2 12 Quasi-instantaneous circuit LTL1-1/9/Q LV HRC fuse switch-disconnectors, size 00 Example: Surface mounting with accessories, 3-pole LVHRC fuselinks Basic construction 1 Base of disconnector U-LTL00-3 2 Protective cover, top BO-LTL00-3 3 Protective cover, bottom BU-LTL00-3 4 Swing-in device D-LTL00-3/9 4 5 Screw terminal F-M8x16 6 Clamp-type terminal S00 7 V-terminal clamp P0070 15 Covering accessories (Protection against contact) 2 3 8 Handle protection, top GO-LTL00-3 9 Handle protection, bottom GU-LTL00-3 Fixing accessories 12 10 7 6 14 11 Protective cover interlock VHG-LTL00123-3 12 Mech. fuse monitor K-LTL00-3/H 13 Position indicator, “ON” (electrical interlocking) eV-LTL00-3 5 8 LV HRC fuse switch-disconnectors with quasi-instantaneous circuit 14 10 1 9 Quasi-instantaneous circuit LTL00-3/9/Q Accessories: Swing-in device with electronic fuse monitor 15 Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways DIN rail fixing parts Z-LTL00-3 Accessories for interlocking, mechanical fuse monitoring and “ON” position indication 11 13 Dtype fuselinks Dtype fusebases Connection accessories 13 HVHRC fuselinks LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Swing-in device D-LTL00-3/9/Es00 Distribution nt and instrume cabinets 10 Electronic monitoring devices Measurement n data acquisitio s system Software 11-3 Appendix Current distribution components LV HRC fuse switchdisconnectors 1-pole / surface mounting 2.40.01.010 Size 00 to size 4a Product Definition LV HRC fuse switch-disconnectors in accordance with EN 60947-3 with swing-in device for accomodating one LV HRC fuse-link in accordance with DIN 43620, sizes 00/160A to 4a/1600A. Applications Switchgear for system, cable and motor protection in alternating and direct current systems. The disconnectors are frequently used in battery-powered direct current systems such as UPS systems. Operational principle Using manually-operated swing-in devices, the LV HRC fuse-links are swung in (making operation) and pulled out (breaking operation). Product construction Swing-in device made of halogen-free self-extinguishing plastics. Split latch-on contact cover. Standard disconnectors are equipped with screw terminals, but can be retrofitted with direct-connection terminals. Accessories • Direct-connection terminals • Mechanical fuse monitor 11-4 • Overreaching protection for upper and lower connection contacts • Output indicator Size Rated operational current (A) Std.P Type Art. no. LTL... 00 160 3 00-1/9 T5911012 1 250 1 1-1/9 T1911033 3 630 1 3-1/9 T3911033 4a 1250 1 4A-1X/1250/8 T4311007 4a 1600 1 4A-1X/1600/8 T4311008 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-5 Appendix Current distribution components LV HRC fuse switchdisconnectors 1-pole / surface mounting 2.40.01.020 Accessories Product defininition CLAMP-TYPE TERMINAL Direct-connection terminal clamp-type terminal for Cu conductor and ribbon conductor connection. V-TERMINAL CLAMP Direct-connection terminal V-terminal clamp for Cu conductor and Al conductor connection. OUTPUT INDICATOR Output indicator for indication of connected or disconnected state. 11-6 MECHANICAL FUSE MONITOR Mechanical fuse monitor for indication of fuse failure. PROTECTIVE COVER INTERLOCK Interlocking element for contact covers, ensures that the covers can only be removed by a tool (screwdriver). HANDLE PROTECTION Handle protection, top and bottom. Prevents accidental contact with live parts. HANDLE PROTECTION FOR BLADES Handle protection for blades. This is mounted in the swing-in device and prevents accidental contact with the contact blades of the fuse-links when the swing-in device is not entirely closed. Applications All accessories are available as kits for retrofitting. Flat termination Std.P Type Art. no. Size 00 3 F-LTL00-M8 K9910001 Size 1 3 F-LTL1-M10 K9910007 Size 3 3 F-LTL3-M10 K9910010 Clamp-type terminal Std.P Type Art. no. Size 00 0 S00 K5041013 Size 1 3 S1 K1011005 Size 3 3 S3 K3011005 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks V-terminal clamp Std.P Type Art. no. Size 00 1 P0070 K5141038 Size 1 3 P1 K1111001 Size 3 3 P3 K3111001 Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system V-terminal clamp for 2-wire connection Std.P Type Art. no. Size 1 (no „K“ version) 3 P12 K1112002 Size 3 (no „K“ version) 3 P32 K3112002 Switchdisconnectorfuses (SASIL) BS system Terminals Direct-connection terminal Std.P Type Art. no. Size 4a, 3-wire connection 1 K3G/3/AF40-50 K3203015 Size 4a, 4-wire connection 1 K3G/4/A40-50 K3204016 Size 4a, 2-wire connection 1 KV2HG/2/300/AF40-50 K2322064 LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di Position indicator Std.P Type Art. no. Size 00 1 EV-LTL00-3 T8520048 Sizes 1 and 3 1 EV-LTL123-1 T8920049 LV HRC fusebases LV HRC fuse switchctors ne on disc Mechanical fuse monitor Std.P Type Art. no. Size 00 (no „GU“) 1 K-LTL00-1/H T8520003 Size 1 (no „P12") 1 K-LTL1-1/H T8120050 Size 3 (no „P32") 1 K-LTL3-1/H T8320051 Size 4a 1 K-LTL4A T8420057 Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Handle protection Std.P Type Art. no. Size 00, top 1 GO-LTL00-1 T8590392 Size 1, top and bottom 1 GOU-LTL1-1 T8190394 Size 3, top and bottom 1 GOU-LTL3-1 T8390405 Size 00, bottom (no „K“ version) 1 GU-LTL00-1 T8590393 Electronic monitoring devices Measurement n data acquisitio s system Software 11-7 Appendix 11-8 DIN rail fixing parts Std.P Type Art. no. Size 00 (100mm-150mm DIN rail distance) 1 Z-LTL00-3 T8530011 Swing-in device for earthing Std.P Type Art. no. Size 4a, earthing at the top 1 D-E-LTL4A-1/8/EO T8460203 Size 4a, earthing at the bottom 1 D-E-LTL4A-1/8/EU T8460204 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-9 Appendix Current distribution components LV HRC fuse switchdisconnectors 2-pole / surface mounting 2.40.02.010 Size 00 to size 3 Product Definition LV HRC fuse switch-disconnectors in accordance with EN 60947-3 with swing-in device for accomodating 2 LV HRC fuse-links in accordance with DIN 43620, sizes 00/160A to 3/630A. Applications Switchgear for system, cable and motor protection in alternating and direct current systems. The disconnectors are frequently used in battery-powered direct current systems such as UPS systems. Operational principle Using manually-operated swing-in devices, the LV HRC fuse-links are swung in (making operation) and pulled out (breaking operation). Product construction Swing-in device made of halogen-free self-extinguishing plastics. Split latch-on contact cover. Standard disconnectors are equipped with screw terminals, but can be retrofitted with direct-connection terminals. Accessories • Direct-connection terminals [S00] • Mechanical fuse monitor [[K-LTL00-1/H] 11-10 • Overreaching protection for upper and lower connection contacts [G0-LTL00-1] • Output indicator [EV-LTL00-3] • DIN rail fixing parts [Z-LTL00-3] Size Std.P Type Art. no. LTL... 00 1 00-2/9 T5911013 1 1 1-2/9 T1911039 3 1 3-2/9 T3911035 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-11 Appendix Current distribution components LV HRC fuse switchdisconnectors 2-pole / surface mounting 2.40.02.020 Accessories Product Definition The retrofittable direct-connection terminals allow direct connection of conductors or ribbon conductors. In conjunction with LV HRC fuse-links with striker, the mechanical fuse monitor indicates fuse failure. The striker actuates a microswitch when the fuse-link is disconnected. The microswitch then passes the failure signal to a control centre. The upper and lower latch-on overreaching protection covers the connection contacts or cable lugs or bare protruding conduc- 11-12 tors. The live parts are covered probe-safe. The retrofittable DIN rail fixing parts consist of two hang-up hooks and a slide. They allow size 00 LV HRC fuse switch-disconnectors to be fixed on two standard rails in accordance with EN 50022 with 100mm to 150mm distance between rail centres. Applications Direct-connection terminals replace cable lugs. They are suitable for Cu conductors, ribbon conductors and Cu busbars. Mechanical fuse monitors are used for remote indication of fuse failure. The overreaching protection prevents accidental contact with live parts. The DIN rail fixing parts for size 00 LV HRC fuse switch-disconnectors are used in control cabinets in combination with miniature circuit-breakers and in distribution systems in which only standard rails in accordance with EN 50022 are integrated. Flat termination Std.P Type Art. no. Size 00 3 F-LTL00-M8 K9910001 Size 1 3 F-LTL1-M10 K9910007 Size 3 3 F-LTL3-M10 K9910010 Clamp-type terminal Std.P Type Art. no. Size 00 3 S00 K5041013 Size 1 3 S1 K1011005 Size 3 3 S3 K3011005 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks V-terminal clamp Std.P Type Art. no. Size 00 1 P0070 K5141038 Size 1 3 P1 K1111001 Size 3 3 P3 K3111001 Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system V-terminal clamp for 2-wire connection Std.P Type Art. no. Size 1 (no „K“ version) 3 P12 K1112002 Size 3 (no „K“ version) 3 P32 K3112002 Switchdisconnectorfuses (SASIL) BS system Terminals Position indicator Std.P Type Art. no. Size 00 1 EV-LTL00-3 T8520048 Sizes 1 and 3 1 EV-LTL123-1 T8920049 LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di Mechanical fuse monitor Std.P Type Art. no. Size 00 (no „GU“) 1 K-LTL00-1/H T8520003 Size 1 (no „P12") 1 K-LTL1-1/H T8120050 Size 3 (no „P32") 1 K-LTL3-1/H T8320051 LV HRC fusebases LV HRC fuse switchctors ne on disc Handle protection Std.P Type Art. no. Size 00, top 1 GO-LTL00-1 T8590392 Size 1, top and bottom 1 GOU-LTL1-1 T8190394 Size 3, top and bottom 1 GOU-LTL3-1 T8390405 Size 00, bottom (no „K“ version) 1 GU-LTL00-1 T8590393 DIN rail fixing parts Std.P Type Art. no. Size 00 (100mm-150mm DIN rail distance) 1 Z-LTL00-3 T8530011 Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-13 Appendix Current distribution components LV HRC fuse switchdisconnectors 3-pole / surface mounting 2.40.03.010 Size 00 to size 4a Product Definition Operational principle LV HRC fuse switch-disconnectors in accordance with EN 60947-3 with swing-in device for accomodating 3 LV HRC fuse-links in accordance with DIN 43620, sizes 00/160A to 4a/1600A. Using manually-operated swing-in devices, the LV HRC fuse-links are swung in (making operation) and pulled out (breaking operation). Applications Swing-in device made of halogen-free self-extinguishing plastics. Size 00 and 1 disconnectors have a sealable mechanical interlock and a sliding window for voltage testing. Split latch-on contact cover. Standard disconnectors are Switchgear for system, cable and motor protection in three-phase systems up to 690V AC. The disconnectors are fitted in switchgear cabinets or insulating cases. equipped with bolt connections, but can be retrofitted with direct-connection terminals. Product construction Accessories • Direct-connection terminals [S00] • Mechanical fuse monitor [K-LTL4A] • Overreaching protection for upper and lower con- 11-14 nection contacts [GO-LTL00-3] • Overreaching protection for contact blades of fuse-links [GM-LTL1-3] • Covering panels [A001] • DIN rail fixing parts [Z-LTL00-3] • Protective cover interlock [VHG-LTL00123-3] • Output indicator [EV-LTL00-3] Size Switched poles Electronic fuse monitor Quasi-instantaneou s circuit Std.P Type Art. no. LTL... 00 3 Without Without 1 00-3/9 00 3 With Without 1 00-3/9/ES00 T5999035 T5711200 1 3 Without Without 1 1-3/9 T1999001 1 3 With Without 1 1-3/9/ES00 T1711200 2 3 Without Without 1 2-3/9 T2999001 2 3 With Without 1 2-3/9/ES00 T2711200 3 3 Without Without 1 3-3/9 T3999001 3 3 With Without 1 3-3/9/ES00 T3711200 4a 1 Without Without 1 4A-3X/1250/8 T4311009 4a 1 Without With 1 4A-3X/1250/8/Q T4311043 4a 1 Without Without 1 4A-3X/1600/8 T4311010 4a 1 Without With 1 4A-3X/1600/8/Q T4311044 4a 3 Without Without 1 4A-3X3/1250/8 T4311011 4a 3 Without With 1 4A-3X3/1250/8/Q T4311022 4a 3 Without Without 1 4A-3X3/1600/8 T4311012 4a 3 Without With 1 4A-3X3/1600/8/Q T4311046 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-15 Appendix Current distribution components LV HRC fuse switchdisconnectors 3-pole / surface mounting 2.40.03.020 Accessories Product Definition The retrofittable direct-connection terminals allow direct connection of conductors or ribbon conductors. In conjunction with LV HRC fuse-links with striker, the mechanical fuse monitor indicates fuse failure. The striker actuates a microswitch when the fuse-link is disconnected. The microswitch then passes the failure signal to a control centre. The retrofittable DIN rail fixing parts consist of two hang-up hooks and a slide. They allow size 00 LV HRC fuse switch-disconnectors to be fixed on two standard rails in accordance with EN 50022 with 100mm to 150mm distance between rail centres. The protective cover interlock can be latched into the protective covers. It is interlocked with the basic frame by a 90° turn of a screwdriver. The upper and lower latch-on overreaching protection covers the connection contacts or cable lugs or bare protruding conductors. The live parts are covered probe-safe. Applications The overreaching protection for the contact blades of the LV HRC fuse-links is movably fitted in the front plate. When the front plate is swung out, the overreaching protection is swung out from the front plate on the face, thus covering the contact blades of the fuse-links probe-safe. Mechanical fuse monitors are used for remote indication of fuse failure. The latch-on covering panels cover the switchboard apertures and ensure IP30 protection in the connected state. 11-16 Direct-connection terminals replace cable lugs. They are suitable for Cu conductors, ribbon conductors and Cu busbars. The overreaching protection prevents accidental contact with live parts. The overreaching protection for the contact blades of the LV HRC fuse-links is used for supply from below. It prevents accidental contact with the live contact blades of the fuse-links when the front plate is not entirely closed. Covering panels are used for panel mounting. They ensure complete covering of the panel cutouts and thus IP30 protection. The DIN rail fixing parts for size 00 LV HRC fuse switch-disconnectors are used in control cabinets in combination with miniature circuit-breakers and in distribution systems in which only standard rails in accordance with EN 50022 are integrated. Protective cover interlocks ensure that the covers can only be removed by a tool, thus complying with VGB4 requirements. Flat termination Std.P Type Art. no. Size 00 3 F-LTL00-M8 K9910001 Size 1 3 F-LTL1-M10 K9910007 Size 2 3 F-LTL2-M10 K9910008 Size 3 3 F-LTL3-M10 K9910010 LVHRC fuselinks Clamp-type terminal Std.P Type Art. no. Size 00 3 S00 K5041013 Size 1 3 S1 K1011005 Size 2 3 S2 K2011005 Size 3 3 S3 K3011005 V-terminal clamp Std.P Type Art. no. Size 00 1 P0070 K5141038 Size 1 3 P1 K1111001 Size 2 3 P2 K2111001 Size 3 3 P3 K3111001 HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system V-terminal clamp for 2-wire connection Std.P Type Art. no. Size 1 (no „K“ version) 3 P12 K1112002 Size 2 (no „K“ version) 3 P22 K2112002 Size 3 (no „K“ version) 3 P32 K3112002 Terminals LV HRC stripfuseways Direct-connection terminal Std.P Type Art. no. Size 4a, 3-wire connection 1 K3G/3/AF40-50 K3203015 Size 4a, 4-wire connection 1 K3G/4/A40-50 K3204016 Size 4a, 2-wire connection 1 KV2HG/2/300/AF40-50 K2322064 LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases Position indicator Std.P Type Art. no. Size 00 1 EV-LTL00-3 T8520048 Sizes 1 and 3 1 EV-LTL123-1 T8920049 LV HRC fuse switchctors ne on disc Busbar system components Position indicator Std.P Type Art. no. Size 00, 3-pole (no „GU“) 1 K-LTL00-3/H T8520029 Size 1, 3-pole (no „P12") 1 K-LTL1-3/H T8120030 Size 2 (no „P22") 1 K-LTL2-3/H T8220031 Size 3, 3-pole (no „P32") 1 K-LTL3-3/H T8320032 Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-17 Appendix 11-18 Handle protection Std.P Type Art. no. Size 00, top 1 GO-LTL00-3 T8590019 Size 1, top 1 GO-LTL1-3 T8190184 Size 2, top 1 GO-LTL2-3 T8290219 Size 3, top 1 GO-LTL3-3 T8390223 Size 00, bottom 3-pole (no „K“ version) 1 GU-LTL00-3 T8590179 Size 1, bottom 1 GU-LTL1-3 T8190185 Size 2, bottom 1 GU-LTL2-3 T8290220 Size 3, bottom 1 GU-LTL3-3 T8390224 DIN rail fixing parts Std.P Type Art. no. Size 00 (100mm-150mm DIN rail distance) 1 Z-LTL00-3 T8530011 Swing-in device for earthing Std.P Type Art. no. Size 4a, earthing at the top 1 D-E-LTL4A-3/8/EO T8460040 Size 4a, earthing at the bottom 1 D-E-LTL4A-3/8/EU T8460041 Covering panels Std.P Type Art. no. Size 00 1 A001 T8540002 Size 1 1 A101 T8140019 Size 2 1 A201 T8240024 Size 3 1 A301 T8340029 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-19 Appendix Current distribution components LV HRC fuse switchdisconnectors 4-pole / surface mounting 2.40.04.010 Size 00 to size 3 Product Definition Applications LV HRC fuse switch-disconnectors in accordance with EN 60947-3 with swing-in device for accomodating 4 LV HRC fuse-links in accordance with DIN 43620 or 3 LV HRC fuse-links and one disconnecting blade, sizes 00/160A to 3/630A. Switchgear for system, cable and motor protection in three-phase networks (TN-S networks, separate N and PE conductors). Operational principle Using manually-operated swing-in devices, the LV HRC fuse-links are swung in (making operation) and pulled out (breaking opera- Accessories • Direct-connection terminal [S00] • Mechanical fuse monitor [K-LTL00-3/H] • Overreaching protection for upper and lower con- 11-20 nection contacts [G0-LTL00-3] • Output indicator [EV-LTL00-3] • DIN rail fixing parts [Z-LTL00-3] tion). All 4 poles are switched simultaneously. Product construction Swing-in device made of halogen-free self-extinguishing plastics. Split latch-on contact cover. Standard disconnectors are equipped with screw terminals, but can be retrofitted with direct-connection terminals. Size Std.P Type Art. no. LTL... 00 1 00-4/9 T5911014 1 1 1-4/9 T1911036 3 1 3-4/9 T3911037 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-21 Appendix Current distribution components LV HRC fuse switchdisconnectors 4-pole / surface mounting 2.40.04.020 Accessories Product Definition The retrofittable direct-connection terminals allow direct connection of conductors or ribbon conductors. In conjunction with LV HRC fuse-links with striker, the mechanical fuse monitor indicates fuse failure. The striker actuates a microswitch when the fuse-link is disconnected. The microswitch then passes the failure signal to a control centre. The upper and lower latch-on overreaching protection covers the connec- 11-22 tion contacts or cable lugs or bare protruding conductors. The live parts are covered probe-safe. The retrofittable DIN rail fixing parts consist of two hang-up hooks and a slide. They allow size 00 LV HRC fuse switch-disconnectors to be fixed on two standard rails in accordance with EN 50022 with 100mm to 150mm distance between rail centres. Applications Direct-connection terminals replace cable lugs. They are suitable for Cu conductors, ribbon conductors and Cu busbars. Mechanical fuse monitors are used for remote indication of fuse failure. The overreaching protection prevents accidental contact with live parts. The DIN rail fixing parts for size 00 LV HRC fuse switch-disconnectors are used in control cabinets in combination with miniature circuit-breakers and in distribution systems in which only standard rails in accordance with EN 50022 are integrated. Flat termination Std.P Type Art. no. Size 00 3 F-LTL00-M8 K9910001 Size 1 3 F-LTL1-M10 K9910007 Size 3 3 F-LTL3-M10 K9910010 Clamp-type terminal Std.P Type Art. no. Size 00 3 S00 K5041013 Size 1 3 S1 K1011005 Size 3 3 S3 K3011005 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks V-terminal clamp Std.P Type Art. no. Size 00 1 P0070 K5141038 Size 1 3 P1 K1111001 Size 3 3 P3 K3111001 Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system V-terminal clamp for 2-wire connection Std.P Type Art. no. Size 1 (no „K“ version) 3 P12 K1112002 Size 3 (no „K“ version) 3 P32 K3112002 Switchdisconnectorfuses (SASIL) BS system Terminals Position indicator Std.P Type Art. no. Size 00 1 EV-LTL00-3 T8520048 Sizes 1 and 3 1 EV-LTL123-1 T8920049 Mechanical fuse monitor Std.P Type Art. no. Size 00, 3-pole (no „GU“) 1 K-LTL00-3/H T8520029 Size 00, (no „GU“) 1 K-LTL00-1/H T8520003 Size 1 (no „P12") 1 K-LTL1-1/H T8120050 Size 3 (no „P32") 1 K-LTL3-1/H T8320051 Size 1, 3-pole (no „P12") 1 K-LTL1-3/H T8120030 Size 3, 3-pole (no „P32") 1 K-LTL3-3/H T8120032 LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Handle protection Std.P Type Art. no. Size 00, top 1 GO-LTL00-3 T8590019 Size 1, top 1 GO-LTL1-3 T8190184 Size 3, top 1 GO-LTL3-3 T8390223 Size 00, bottom 3-pole (no „K“ version) 1 GU-LTL00-3 T8590179 Size 1, bottom 1 GU-LTL1-3 T8190185 Size 3, bottom 1 GU-LTL3-3 T8390224 GO-LTL00-1 T8590392 Size 00, top Size 1, top and bottom 1 GOU-LTL1-1 T8190394 Size 3, top and bottom 1 GOU-LTL3-1 T8390405 Size 00, bottom (no „K“ version) 1 GU-LTL00-1 T8590393 Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-23 Appendix 11-24 DIN rail fixing parts Std.P Type Art. no. Size 00 (100mm-150mm DIN rail distance) 1 Z-LTL00-3 T8530011 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-25 Appendix Current distribution components LV HRC fuse switchdisconnectors 1-pole / busbar mounting 2.40.05.010 Size 00 to size 3 Product Definition LV HRC fuse switch-disconnectors in accordance with EN 60947-3 with swing-in device for accomodating one LV HRC fuse-link in accordance with DIN 43620, size 00/160A for screw-fixing or clipping on busbars. Applications Switchgear for system, cable and motor protection in alternating and direct current systems. The disconnectors are frequently used in bat- tery-powered direct current systems such as UPS systems. NOTE: Not for use with 3-pole busbar systems (observe clearances and creepage distances). Operational principle Using manually-operated swing-in devices, the LV HRC fuse-links are swung in (making operation) and pulled out (breaking operation). The disconnectors are supplied directly from the busbar. Bolt connections or optional direct-connection terminals are used for output. Product construction Swing-in device made of halogen-free self-extinguishing plastics. Split latch-on contact cover The disconnectors are mounted directly on the busbar with M8 screws or with busbar terminals. Bolt connections or optional direct-connection terminals are available for cable outlet. Accessories • Direct-connection termi nals [S00] • Mechanical fuse monitor [K-LTL00-1/H] 11-26 • Overreaching protection for upper and lower connection contacts [G0-LTL00-1] • Output indicator [EV-LTL00-3] Size Type of connection Outgoing connection Busbar fixing Std.P Type Art. no. LTL... 00 Flat termination Top Screw 1 00-1/AO 00 Flat termination Bottom Screw 1 00-1/AU T5410502 T5401503 00 Box terminal Top Screw 1 00-1/F70/AO T5470506 00 Box terminal Bottom Screw 1 00-1/F70/AU T5407507 00 Box terminal Top Clamp 1 00-1/F70/SK/AO T5470504 00 Box terminal Bottom Clamp 1 00-1/F70/SK/AU T5407505 00 Flat termination Top Clamp 1 00-1/SK/AO T5410500 00 Flat termination Bottom Clamp 1 00-1/SK/AU T5401501 1 Flat termination Top Screw 1 1-1/AO T1410502 1 Flat termination Bottom Screw 1 1-1/AU T1401503 1 Flat termination Top Clamp 1 1-1/SK/AO T1410500 1 Flat termination Bottom Clamp 1 1-1/SK/AU T1401501 3 Flat termination Top Screw 1 3-1/AO T3410502 3 Flat termination Bottom Screw 1 3-1/AU T3401503 3 Flat termination Top Clamp 1 3-1/SK/AO T3410500 3 Flat termination Bottom Clamp 1 3-1/SK/AU T3401501 4a Flat termination Top Clamp 1 4A-1/AO T4410500 4a Flat termination Bottom Clamp 1 4A-1/AU T4401501 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-27 Appendix Current distribution components LV HRC fuse switchdisconnectors 1-pole / busbar mounting 2.40.05.020 Accessories Product Definition The retrofittable direct-connection terminals allow direct connection of conductors or ribbon conductors. In conjunction with LV HRC fuse-links with striker, the mechanical fuse monitor indicates fuse failure. The striker actuates a microswitch when the fuse-link is disconnected. The microswitch then 11-28 passes the failure signal to a control centre. ribbon conductors and Cu busbars. The upper and lower latch-on overreaching protection covers the connection contacts or cable lugs or bare protruding conductors. The live parts are covered probe-safe. Mechanical fuse monitors are used for remote indication of fuse failure. Applications Direct-connection terminals replace cable lugs. They are suitable for Cu conductors, The overreaching protection prevents accidental contact with live parts. Flat termination Std.P Type Art. no. Size 00 3 F-LTL00-M8 K9910001 Size 1 3 F-LTL1-M10 K9910007 Size 3 3 F-LTL3-M10 K9910010 Clamp-type terminal Std.P Type Art. no. Size 00 3 S00 K5041013 Size 1 3 S1 K1011005 Size 3 3 S3 K3011005 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks V-terminal clamp Std.P Type Art. no. Size 00 1 P0070 K5141038 Size 1 3 P1 K1111001 Size 3 3 P3 K3111001 Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system V-terminal clamp for 2-wire connection Std.P Type Art. no. Size 1 (no „K“ version) 3 P12 K1112002 Size 3 (no „K“ version) 3 P32 K3112002 Switchdisconnectorfuses (SASIL) BS system Terminals Position indicator Std.P Type Art. no. Size 00 1 EV-LTL00-3 T8520048 Sizes 1 and 3 1 EV-LTL123-1 T8920049 LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di Mechanical fuse monitor Std.P Type Art. no. Size 00 (no „GU“) 1 K-LTL00-1/H T8520003 Size 1 (no „P12") 1 K-LTL1-1/H T8120050 Size 3 (no „P32") 1 K-LTL3-1/H T8320051 Size 4a 1 K-LTL4A T8420057 Handle protection Std.P Type Art. no. Size 00, top 1 GO-LTL00-1 T8590392 Size 1, top and bottom 1 GOU-LTL1-1 T8190394 Size 3, top and bottom 1 GOU-LTL3-1 T8390405 Size 00, bottom (no „K“ version) 1 GU-LTL00-1 T8590393 LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-29 Appendix Current distribution components LV HRC fuse switchdisconnectors 3-pole / busbar mounting 2.40.06.010 Size 00 to size 3 Product Definition LV HRC fuse switch-disconnectors in accordance with EN 60947-3 with swing-in device for accomodating 3 LV HRC fuse-links in accordance with DIN 43620, sizes 00/160A to 3/630A. They are directly contacted on busbars with 40, 50, 60 and 100mm distance between busbar centres. Applications Switchgear for system, cable and motor protection in three-phase systems up to AC690V. The disconnectors are fitted in switchgear cabinets or insulating cases with a busbar system of 40, 50, 60 or 100mm distance between busbar centres. Operational principle The devices are fixed on the busbars. Using manually-operated swing-in devices, the LV HRC fuse-links are swung in (making operation) and pulled out (breaking operation). ing. Split latch-on contact cover. Standard disconnectors are equipped with screw terminals, but can be retrofitted with direct-connection terminals. The rear contact system allows direct contacting on the busbars. Product construction Swing-in device made of halogen-free self-extinguishing plastics. Size 00 and 1 disconnectors have a sealable mechanical interlock. Size 00-3 disconnectors have a sliding window for voltage test- Accessories • Clamp-type terminal [S00] • V-terminal clamp [P0070] 11-30 • Output indicator [EV-LTL00-3] • Protective cover interlock [VHG-LTL00123-3] • Handle protection, top [GO-LTL1-3] • Mechanical fuse monitor [K-LTL00-3/H] • Handle protection for blades [GM-LTL1-3] • Covering panels [A004] • Busbar adapter [AL362/AO] Size Busbar distance Outgoing connection Type of connection Electronic fuse monitor Std.P Type Art. no. LTL... 00 40/50/60 Variable Flat termination Without 1 00-3/9/40-60 00 40/50/60 Variable Flat termination With 1 00-3/9/40-60/ES00 T5481000 T5781000 00 40/50/60 Variable F70 Without 1 00-3/9/40-60/F70 T5487001 00 40/50/60 Variable F70 With 1 00-3/9/40-60/F70/ES00 T5787001 1 100 Top Flat termination Without 1 1-3/9/100/AO T1410704 1 100 Top Flat termination With 1 1-3/9/100/AO/ES00 T1710002 1 100 Bottom Flat termination Without 1 1-3/9/100/AU T1401700 1 100 Bottom Flat termination With 1 1-3/9/100/AU/ES00 T1701003 1 60 Top Flat termination Without 1 1-3/9/60/AO T1410707 1 60 Top Flat termination With 1 1-3/9/60/AO/ES00 T1710000 1 60 Bottom Flat termination Without 1 1-3/9/60/AU T1401708 1 60 Bottom Flat termination With 1 1-3/9/60/AU/ES00 T1701001 2 100 Top Flat termination Without 1 2-3/9/100/AO T2410706 2 100 Top Flat termination With 1 2-3/9/100/AO/ES00 T2710002 2 100 Bottom Flat termination Without 1 2-3/9/100/AU T2401700 2 100 Bottom Flat termination With 1 2-3/9/100/AU/ES00 T2701003 2 60 Top Flat termination Without 1 2-3/9/60/AO T2410707 2 60 Top Flat termination With 1 2-3/9/60/AO/ES00 T2710000 2 60 Bottom Flat termination Without 1 2-3/9/60/AU T2401708 2 60 Bottom Flat termination With 1 2-3/9/60/AU/ES00 T2701001 3 100 Top Flat termination Without 1 3-3/9/100/AO T3410703 3 100 Top Flat termination With 1 3-3/9/100/AO/ES00 T3710000 3 100 Bottom Flat termination Without 1 3-3/9/100/AU T3401700 3 100 Bottom Flat termination With 1 3-3/9/100/AU/ES00 T3701001 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-31 Appendix Current distribution components LV HRC fuse switchdisconnectors 3-pole / busbar mounting 2.40.06.020 Accessories Product defininition CLAMP-TYPE TERMINAL Direct-connection terminal clamp-type terminal for Cu conductor and ribbon conductor connection. V-TERMINAL CLAMP Direct-connection terminal V-terminal clamp for Cu conductor and Al conductor connection. OUTPUT INDICATOR Output indicator for indication of connected or disconnected state. 11-32 MECHANICAL FUSE MONITOR Mechanical fuse monitor for indication of fuse failure. PROTECTIVE COVER INTERLOCK Interlocking element for contact covers, ensures that the covers can only be removed by a tool (screwdriver). HANDLE PROTECTION Handle protection, top and bottom. Prevents accidental contact with live parts. HANDLE PROTECTION FOR BLADES Handle protection for blades. This is mounted in the swing-in device and prevents accidental contact with the contact blades of the fuse-links when the swing-in device is not entirely closed. Applications All accessories are available as kits for retrofitting. Flat termination Std.P Type Art. no. Size 00 3 F-LTL00-M8 K9910001 Size 1 3 F-LTL1-M10 K9910007 Size 2 3 F-LTL2-M10 K9910008 Size 3 3 F-LTL3-M10 K9910010 LVHRC fuselinks Clamp-type terminal Std.P Type Art. no. Size 00 3 S00 K5041013 Size 1 3 S1 K1011005 Size 2 3 S2 K2011005 Size 3 3 S3 K3011005 V-terminal clamp Std.P Type Art. no. Size 00 1 P0070 K5141038 Size 1 3 P1 K1111001 Size 2 3 P2 K2111001 Size 3 3 P3 K3111001 HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system V-terminal clamp for 2-wire connection Std.P Type Art. no. Size 1 (no „K“ version) 3 P12 K1112002 Size 2 (no „K“ version) 3 P22 K2112002 Size 3 (no „K“ version) 3 P32 K3112002 Terminals LV HRC stripfuseways Position indicator Std.P Type Art. no. Size 00 1 EV-LTL00-3 T8520048 Sizes 1 and 3 1 EV-LTL123-1 T8920049 LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases Position indicator Std.P Type Art. no. Size 00, 3-pole (no „GU“) 1 K-LTL00-3/H T8520029 Size 1, 3-pole (no „P12") 1 K-LTL1-3/H T8120030 Size 2 (no „P22") 1 K-LTL2-3/H T8220031 Size 3, 3-pole (no „P32") 1 K-LTL3-3/H T8320032 Handle protection Std.P Type Art. no. Size 00, top 1 GO-LTL00-3/195 T8590462 Size 1, top 1 GO-LTL1-3 T8190184 Size 2, top 1 GO-LTL2-3 T8290219 Size 3, top 1 GO-LTL3-3 T8390223 Size 00, top, extended 1 GOV-LTL00-3/230 T8590459 Size 00, bottom 1 GU-LTL00-3/195 T8590463 Size 1, bottom 1 GU-LTL1-3 T8190185 Size 2, bottom 1 GU-LTL2-3 T8290220 Size 3, bottom 1 GU-LTL3-3 T8390224 Size 00, bottom, extended 1 GUV-LTL00-3/230 T8590460 LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-33 Appendix 11-34 Handle protection for blades Std.P Type Art. no. Size 1 1 GM-LTL1-3 T8190236 Size 2 1 GM-LTL2-3 T8290237 Protective cover interlock Std.P Type Art. no. Sizes 00-3 1 VHG-LTL00123-3 T8920024 Covering panels Std.P Type Art. no. Size 00 1 A004 T8540005 Size 1 1 A108 T8140064 Size 2 1 A206 T8240065 Size 3 1 A301 T8340029 Busbar adapter Std.P Type Art. no. Size 3, top connection / for use with T3999001 1 AL362/AO T8350084 Size 3, bottom connection / for use with T3999001 1 AL362/AU T8350085 86 45 20.5 49 49 9 LVHRC fuselinks HVHRC fuselinks 120 149 149 200 7 Dtype fuselinks 79 Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system 25 Switchdisconnectorfuses (SASIL) BS system 17 Befestigungsmasse Terminals LTL00-1/9 Ordering details see page 11-5 LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system LTL1-1/9 Ordering details see page 11-5 Software 11-35 Appendix LTL3-1/9 Ordering details see page 11-5 218 96 25 185 270 315 338.5 346 350 25 30 7 9 13 Befestigungsmasse 108 6 45 13 116 40 154.5 LTL4A-1X/1250/8 Ordering details see page 11-5 11-36 1 x M16 x 60 - 1250A 2 x M12 x 60 - 1600A 218 96 LVHRC fuselinks 25 9 270 315 338.5 346 350 25 30 7 HVHRC fuselinks Dtype fuselinks 185 13 Dtype fusebases Befestigungsmasse 108 6 45 1 x M16 x 60 - 1250A 2 x M12 x 60 - 1600A 13 116 40 Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system 154.5 Terminals LTL4A-1X/1600/8 Ordering details see page 11-5 LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di 88.5 98 23 45 LV HRC fusebases 9 98 149 120 Busbar system components 74.5 79 200 149 7 LV HRC fuse switchctors ne on disc Distribution nt and instrume cabinets 25 49 Consumer gy supply technolo 17 Electronic monitoring devices Befestigungsmasse Measurement n data acquisitio s system LTL00-2/9 Ordering details see page 11-11 Software 11-37 Appendix LTL1-2/9 Ordering details see page 11-11 LTL3-2/9 Ordering details see page 11-11 11-38 L1* L* LTL2 - 3/9 210 LTL1 - 3/9 184 E A F LVHRC fuselinks 128 115 230 256 10.5 11 11 D 100 HVHRC fuselinks H C LTL3 - 3/9 254 B 100 7 Dtype fuselinks 79 Dtype fusebases 135 149 270 11 LTL00 - 3/9 105.5 I 66 125 Switch-diss connector-fuseC (SASIL) LV HR system Befestigungsmasse Typ LTL00 - 3/9 LTL1 - 3/9 LTL2 - 3/9 LTL3 - 3/9 A 105.5 184 210 254 B 149 230 256 270 C 200 317 397 430 D 45 68 81 96 E 86 119 133 147 F G H I L* 20.5 74.5 120 17 116 16.5 115 177 25 149 16.5 128 205 25 163 9 135 220.5 30.5 177 L1* 181 214 228 242 Switchdisconnectorfuses (SASIL) BS system Terminals LTL00-3/9 Ordering details see page 11-15 LV HRC stripfuseways L1* E A F 10.5 11 11 D 256 230 100 LV HRC fuse switchctors ne on disc H C B 100 LTL3 - 3/9 254 7 Busbar system components 79 Consumer gy supply technolo 135 149 270 11 LTL00 - 3/9 105.5 I 66 125 Distribution nt and instrume cabinets Befestigungsmasse Typ LTL00 - 3/9 LTL1 - 3/9 LTL2 - 3/9 LTL3 - 3/9 LV HRC fusebases 128 115 LV HRC strip-type fuse ectors nn sco switch-di L* LTL2 - 3/9 210 LTL1 - 3/9 184 A 105.5 184 210 254 B 149 230 256 270 C 200 317 397 430 D 45 68 81 96 E 86 119 133 147 F G H I L* 20.5 74.5 120 17 116 16.5 115 177 25 149 16.5 128 205 25 163 9 135 220.5 30.5 177 L1* 181 214 228 242 Electronic monitoring devices Measurement n data acquisitio s system LTL1-3/9 Ordering details see page 11-15 Software 11-39 Appendix L1* L* LTL2 - 3/9 210 LTL1 - 3/9 184 E A F 128 115 230 256 10.5 11 11 D 100 H C LTL3 - 3/9 254 B 100 7 149 135 79 270 11 LTL00 - 3/9 105.5 I 66 125 Befestigungsmasse Typ LTL00 - 3/9 LTL1 - 3/9 LTL2 - 3/9 LTL3 - 3/9 A 105.5 184 210 254 B 149 230 256 270 C 200 317 397 430 D 45 68 81 96 E 86 119 133 147 F G H I L* 20.5 74.5 120 17 116 16.5 115 177 25 149 16.5 128 205 25 163 9 135 220.5 30.5 177 L1* 181 214 228 242 LTL2-3/9 Ordering details see page 11-15 L1* L* LTL2 - 3/9 210 LTL1 - 3/9 184 E A F 128 115 230 256 10.5 11 11 D 100 H C LTL3 - 3/9 254 B 100 7 149 135 79 270 11 LTL00 - 3/9 105.5 I 66 125 Befestigungsmasse Typ LTL00 - 3/9 LTL1 - 3/9 LTL2 - 3/9 LTL3 - 3/9 A 105.5 184 210 254 B 149 230 256 270 C 200 317 397 430 LTL3-3/9 Ordering details see page 11-15 11-40 D 45 68 81 96 E 86 119 133 147 F G H I L* 20.5 74.5 120 17 116 16.5 115 177 25 149 16.5 128 205 25 163 9 135 220.5 30.5 177 L1* 181 214 228 242 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LTL4A-3X/... Ordering details see page 11-15 LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system LTL00-4/9 Ordering details see page 11-21 Software 11-41 Appendix LTL1-4/9 Ordering details see page 11-21 LTL3-4/9 Ordering details see page 11-21 11-42 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LTL00-1/AO Ordering details see page 11-27 LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system LTL00-1/AU Ordering details see page 11-27 Software 11-43 Appendix LTL00-1/SK/AO Ordering details see page 11-27 LTL00-1/SK/AU Ordering details see page 11-27 11-44 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LTL1-1/AO Ordering details see page 11-27 LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system LTL1-1/AU Ordering details see page 11-27 Software 11-45 Appendix LTL1-1/SK/AO Ordering details see page 11-27 LTL1-1/SK/AU Ordering details see page 11-27 11-46 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LTL3-1/AO Ordering details see page 11-27 LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system LTL3-1/SK/AO Ordering details see page 11-27 Software 11-47 Appendix LTL3-1/SK/AU Ordering details see page 11-27 LTL4A-1/AU Ordering details see page 11-27 11-48 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LTL4A-1/AO Ordering details see page 11-27 LV HRC stripfuseways 118 102 LV HRC strip-type fuse ectors nn sco switch-di 40 31 U T S 158 194 229 151 S 112 106.4 12 4 LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo 32 35 Typ LTL00-3/9/40-60 S 40 50 60 60 105.5 Distribution nt and instrume cabinets T U 12 5-10 20 5-15 20-30 5-10 Electronic monitoring devices Measurement n data acquisitio s system LTL00-3/9/40-60... Ordering details see page 11-31 Software 11-49 Appendix LTL1-3/9/100/AO... Ordering details see page 11-31 LTL1-3/9/100/AU... Ordering details see page 11-31 11-50 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LTL1(2)-3/9/60... Ordering details see page 11-31 LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system LTL2-3/9/100/... Ordering details see page 11-31 Software 11-51 Appendix LTL3-3/9/100/... Ordering details see page 11-31 11-52 C D B/2 F B B C E E 4.5 C A A Abmessungen Typ A 25 P0070 P0095 29 37 P1 P12 37 42 P2 P22 42 P3 50 P32 50 B 15 15 20 20 22 22 25 25 C 15 18 25 25 28 28 30 30 D M5 M5 M6 M6 M8 M8 M8 M8 Clamp-type terminal V-terminal clamp Ordering details see page 11-7 Ordering details see page 11-7 E max. 25 max. 28 max. 30 max. 42 max. 40 max. 55 max. 44 max. 66 F 5.5 5.5 6.5 6.5 8.5 8.5 8.5 8.5 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-53 Appendix KV2HG/2/300/AF40-50 K3G/3/AF40-50 Ordering details see page 11-7 Ordering details see page 11-7 K3G/4/A40-50 D-E-LTL4A-1/8/... Ordering details see page 11-7 Ordering details see page 11-8 11-54 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals A001 A101 Ordering details see page 11-18 Ordering details see page 11-18 LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di 274 LV HRC fusebases LV HRC fuse switchctors ne on disc 143 300 Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets 10.5 Electronic monitoring devices Measurement n data acquisitio s system A201 A301 Ordering details see page 11-18 Ordering details see page 11-18 Software 11-55 Appendix A004 AL362/AO Ordering details see page 11-34 Ordering details see page 11-34 AL362/AU Ordering details see page 11-34 11-56 B LVHRC fuselinks HVHRC fuselinks 300 Dtype fuselinks A Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Typ A108 A206 A 143 156 B 205 236 27 Terminals A108, A206 Ordering details see page 11-34 LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-57 Appendix Technical data for fuse switch-disconnectors (in accordance with IEC/EN 60947-3 and VDE 0660 Part 107) Type LTL00-1/9 LTL00-2/9 LTL00-3/9 LTL00-3/9/40-60 LTL00-4/9 Electrical Rated operational voltage characteristics Rated operational current Conventional free air thermal current with fuses Conventional free air thermal current with solid links Rated frequency Rated insulation voltage Rated conditional short-circuit current Rated short-time withstand current (1sec) Utilization category Rated making capacity Rated breaking capacity Rated impulse withstand voltage Operating cycles with current Total power loss at Ith (without fuse) 3) Size to DIN 43 620 Max. rated current (gL/gG) Max. permis. power loss per fuse-link Fuselinks Operating cycles without current Mechanical characteristics Weight 1) Busbar distance (3-pole) Cable connection Flat terminal Terminal Terminal Terminal Terminal Type of protection Front side Device fitted Operating conditions Ambient temperature 2) Rated operating mode Actuation Mounting position Altitude Pollution degree Overvoltage category Bolt diameter Cable lug (DIN 46 235) Flat bar Tightening torque Clamping cross-section Tightening torque Clamping cross-section Tightening torque Clamping cross-section Tightening torque Clamping cross-section Tightening torque Operational state Front cover open 1) Without packaging 2) 35°C normal temperature, at 55°C with reduced operating current 3) Data for 3-pole version 11-58 Ue Ie Ith Ith Ui Icw Uimp Pv LTL1-1/9 LTL1-2/9 LTL1-3/9 LTL1-3/9/60 LTL1-3/9/100 LTL1-4/9 AC500 AC690 DC220 DC440 AC500 AC690 DC220 DC440 V 160 100 160 100 250 200 250 200 A A 160 100 160 100 250 200 250 200 A 210(TM00) 325(TM1) Hz 40-60 40-60 40-60 40-60 V AC750 AC750 kAeff 50 50 25 25 50 50 25 25 kAeff AC-22B AC-22B DC-22B DC-21B AC-22B AC-22B DC-22B DC-21B 480 300 640 150 750 600 1000 300 A 480 300 640 150 750 600 1000 300 A kV 8 8 8 8 8 8 8 8 300 300 300 300 200 200 200 200 6.9 2.7 6.2 2.7 12.9 8.3 8.6 5.5 W IN Pv A W - kg mm Ma Ma Ma Ma Ma mm2 mm Nm mm2 Nm mm2 Nm mm2 Nm mm2 Nm - - IP20 IP10 IP20 IP10 Tu - °C m - - 25 to + 55 Continuous operation Dependent manual operation Vertical, horizontal Up to 2000 3 III - 25 to + 55 Continuous operation Dependent manual operation Vertical, horizontal Up to 2000 3 III 00 160 100 1 160 100 250 200 250 12 23 1700 0.31/0.63/0.71/1.1 40/50/60 1400 1.1/2.15/3.5/4.55 60/100 200 M8 M10 1 x 10 - 95 (max. width 25mm) 1 x 25 - 150 20 x 10 30 x 10 12 - 15 30 - 35 1.5 -70Cu/Band 6 x 9 x 0.8 25 -150Cu/Band 6x 16x 0.8 S 00 S1 2.6 9.5 10 - 70 Al/Cu 70 - 150 Al/Cu P00 P1 2.6 4.5 35 x 95 Al/Cu 2 x 70 - 95 Al/Cu P 00 - 95 P12 2.6 4.5 2 x 1.5 - 25 Al/Cu Da 9.5 Technical data for fuse switch-disconnectors (in accordance with IEC/EN 60947-3 and VDE 0660 Part 107) Typ LTL2-1/9 LTL2-2/9 LTL2Typ LTL3-1/9 LTL3-2/9 LTL3-3/9 LTL2-1/9 Type 3/9 LTL2-4/9 LTL3-4/9 LTL2-2/9 LTL2-3/9 LTL2-4/9 Electrical Rated operational voltage characteristics Rated operational current Conventional free air thermal current with fuses Conventional free air thermal current with solid links Rated frequency Rated insulation voltage Rated conditional short-circuit current Rated short-time withstand current (1sec) Utilization category Rated making capacity Rated breaking capacity Rated impulse withstand voltage Operating cycles with current Total power loss at Ith (without fuse) 3) Fuselinks Size to DIN 43 620 Max. rated current (gL/gG) Max. permis. power loss per fuse-link Operating cycles without current Mechanical characteristics Weight 1) Busbar distance (3-pole) Cable connection Flat terminal Terminal Terminal Terminal Type of protection Front side Device fitted Operating conditions Ambient temperature 2) Rated operating mode Actuation Mounting position Altitude Pollution degree Overvoltage category Bolt diameter Cable lug (DIN 46 235) Flat bar Tightening torque Clamping cross-section Tightening torque Clamping cross-section Tightening torque Clamping cross-section Tightening torque Operational state Front cover open 1) Without packaging 2) 35°C normal temperature, at 55°C with reduced operating current 3) Data for 3-pole version Ue Ie Ith Ith Ui Icw Uimp Pv LTL3-1/9 LTL3-2/9 LTL3-3/9 LTL3-4/9 V AC500 AC690 DC220 DC440 AC500 AC690 DC220 A 400 315 400 315 630 500 630 A 400 315 400 315 630 500 630 A 520 (TM2) 1000 (TM3) Hz 40-60 40-60 40-60 40-60 V AC750 AC750 kAeff 50 50 25 25 50 50 25 kAeff AC-22B AC-22B DC-22B DC-21B AC-22B AC-22B DC-22B A 1200 945 1600 475 1890 1500 2520 A 1200 945 1600 475 1890 1500 2520 kV 8 8 8 8 8 8 8 200 200 200 200 200 200 200 W 27 16.7 18 11.2 52 32.8 34.6 LVHRC fuselinks DC440 500 500 25 DC-21B 750 750 8 200 21.8 A W - kg mm 800 3.1 60/100 Ma Ma Ma Ma mm2 mm Nm mm2 Nm mm2 Nm mm2 Nm M10 1 x 25-240 30 x 10 30 - 35 25-240Cu/B. 10 x 16 x 0,8 S2 23 120 - 240 Al/Cu P2 11 2 x 120 - 150 Al/Cu P22 11 - - IP20 IP10 IP20 IP10 Tu - °C m - - 25 to + 55 Continuous operation Dependent manual operation Vertical, horizontal Up to 2000 3 III - 25 to + 55 Continuous operation Dependent manual operation Vertical, horizontal Up to 2000 3 III 2 315 400 34 3 315 630 500 630 P32 Switch-diss connector-fuseC (SASIL) LV HR system Terminals 800 1.7/3.92/5.35/7.1 60/100 P3 Dtype fusebases 500 48 S3 Dtype fuselinks Switchdisconnectorfuses (SASIL) BS system IN Pv 400 HVHRC fuselinks M10 1 x 25-300 40 x 10 30 - 35 Band 11 x 21 x 1 23 120 - 300 Al/Cu 11 2 x 120 - 240 Al/Cu 11 LV HRC stripfuseways LV HRC strip-type fuse ectors nn sco switch-di LV HRC fusebases LV HRC fuse switchctors ne on disc Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 11-59 Appendix Technical data for fuse switch-disconnectors (in accordance with IEC/EN 60947-3 and VDE 0660 Part 107) Type LTL4a-1/1250 LTL4a-3/1250 V A A A Hz V kAeff kAeff A A kV W 80 AC - 22B 3750 3750 8 100 32 IN Pv A W 1250 110 - kg Bolt diameter Cable lug (DIN 46 235) Flat bar Tightening torque Clamping cross-section Ma - mm2 mm Nm mm2 Tightening torque Clamping cross-section Tightening torque Clamping cross-section Tightening torque Ma Ma Ma Nm mm2 Nm mm2 Nm - - IP20 IP10 IP20 IP10 Tu - °C m - - 25 to + 55 Continuous operation Dependent manual operation Vertical Up to 2000 3 III - 25 to + 55 Continuous operation Dependent manual operation Vertical Up to 2000 3 III Electrical Rated operational voltage Ue Ie characteristics Rated operational current Conventional free air thermal current with fuses Ith Conventional free air thermal current with solid links Ith Rated frequency Rated insulation voltage Ui Rated conditional short-circuit current Rated short-time withstand current (1sec) Icw Utilization category Rated making capacity Rated breaking capacity Rated impulse withstand voltage Uimp Operating cycles with current Pv Total power loss at Ith (without fuse) 3) Size to DIN 43 620 Max. rated current (gL/gG) Max. permis. power loss per fuse-link Fuselinks Operating cycles without current Mechanical characteristics Weight 1) Cable connection Flat terminal Terminal Terminal Terminal Type of protection Front side Device fitted Operating conditions Ambient temperature 2) Rated operating mode Actuation Mounting position Altitude Pollution degree Overvoltage category Operational state Front cover open 1) Without packaging 2) 35°C normal temperature, at 55°C with reduced operating current 3) Data for 3-pole version 11-60 AC500 1250 1250 LTL4a-1/1600 LTL4a-3/1600 AC690 1000 1000 AC500 1600 1600 40 - 60 40 - 60 AC690 1000 1000 1250 40 - 60 1600 40 - 60 AC800 AC800 80 AC - 21B 1500 1500 8 100 20.5 - 80 AC - 22B 2400 2400 8 100 52 4a 80 AC - 21B 1500 1500 8 100 33.3 4a 1000 110 500 5.3/15.7 1 x M16 400 max. 80 x 30 50 - 60 KV2HG/2/300/ 2 x (95-300) AF40 - 50 40 K3G/3/A40-50 3 x (95-150) 50 K3G/4/A40-50 4 x (95-150) 50 1600 164 1000 164 500 5.3/15.7 2 x M12 max. 80 x 30 35 - 40 KV2HG/2/300/ 2 x (95-300) AF40-50 40 K3G/3/A40-50 3 x (95-150) 50 K3G/4/A40-50 4 x (95-150) 50