DUAL-LITE Serves the architectural, commercial and industrial market place since 1940. Recognized for innovative designs and quality life safety products. Dual-Lite offers LED Emergency lighting units, exit signs, battery packs and central lighting inverters. 392 EV Architectural LED Emergency Light FEATURES • • • • • • Architectural LED based emergency light for wall or ceiling commercial application High impact, flame rated and UV stable white thermoplastic housing Fully adjustable high output LED lamp-heads Environmentally Friendly Nickel Metal Hydride Battery Includes top mount conduit entry Temperature Range: 20°C to 30°C(68°F to 86°F), damp: 10°C to 40°C(50°F to 104°F) UL924 Listed(optional damp location listed) EMERGENCY LIGHTING U.S. Patents Pending ORDERING INFORMATION EV MODEL RATING Blank Standard Model D Damp Location CAPACITY 2 1 W LED heads 4 2W LED heads4 OR SELF DIAGNOSTICS Blank None I Spectron® Listing2 1W LED w/ remote cap. Capacity to run 2 head remote EV2 available with or with-out damp listing, all other models include damp 3 -24K option only available with damp plus Spectron® 4 Not capable of running remote heads 5 Can only be run from EV4 model 6 -0 No-head option only available with EV4D-02L, with or without Spectron® NOTE: Remote Capacity Option will only power the EVR2 and EVO remotes 1 1 OPTIONS B Black Finish 24K 220-240VAC60Hz with Spectron®3 Self-diagnostic 02L 2 watt LED heads5 2 0 No-head option to run external remotes only6 ELECTRONICS POWER CONSUMPTION HZ. AMPS. WATTS 120 240 277 120 240 277 60 60 60 60 60 60 0.015 0.009 0.008 0.022 0.015 0.014 1.10 1.43 1.45 2.00 2.51 2.75 0.61 0.62 0.62 0.73 0.65 0.63 EV2 EV2D AC VOLTAGE POWER FACTOR EV4D EMERGENCY LIGHTING • • • • • 120/277VAC input with Intelligent 2 wire connection AC lockout and Low Voltage disconnect Battery re-charge within 24 hours Optional Self-Test/Self-Diagnostic circuitry MATCHING INDOOR REMOTE FIXTURES WHITE SINGLE BLACK SINGLE EVR2 EVR2B • The EV Series meets proposed California Energy Commission(CEC) requirements for limits on power consumption in maintenance mode with less than 0.5 watts. EV-LED ACCESSORIES MODEL DESCRIPTION VRS3 Vandal resistant shield WGLZ Wire Guard MULTI-UNIT SPACING 5" S 8.5" 2.19" PW 1 fc Average 1 fc Minimum Using 1 Watt Heads Using 2 Watt Heads Using 1 Watt Heads Using 2 Watt Heads Path Width (PW) Spacing (S) Spacing (S) Path Width (PW) Spacing (S) Spacing (S) 3’ 27’ 39’ 3’ 14’ 18’ 6’ 20’ 33’ 6’ 10’ 14’ Meets Life Safety Code minimum illuminance of 0.1 fc and average illuminance of 1.0 fc. Assumes open space with no obstructions, mounting height of 7.5', ceiling height of 9' and reflectances of 80/50/20. Photometry files available on the Dual-Lite web site (www.dual-lite.com). 393 EVHC High Lumen LED Emergency Light FEATURES EMERGENCY LIGHTING • • • • • High lumen output for high mounting height application Fully adjustable LED lamp-heads Long-Life Lithium Iron Phosphate Battery Temperature Range: 10˚C to 40˚C (50˚F to 104˚F) Listed to UL924 standards U.S. Patents Pending ORDERING INFORMATION EVHC MODEL CAPACITY 6 6 Watts 12 12 Watts SELF DIAGNOSTICS Blank No Self-Diagnostics I Spectron® Self-Diagnostics 4 FINISH Blank White B Black OPTIONS 06L 6 Watt LED Lamps1 BC Battery Compartment Only available on EVHC with 12 watt capacity BC option only available in White Finish BC option only available with EVHC6, EVHC6I, EVHC12 or EVHC12I, not available with EVHC12-06L or EVHC12I-06L 4 Not for use with 220-240VAC input 1 2 3 ELECTRONICS INPUT POWER CONSUMPTION EVHC6 EVHC6I EVHC6I2 EVHC6I2I • 120 through 277 VAC, 50/60Hz input with intelligent 2 wire connection AC lockout and Low Voltage disconnect Battery re-charge within 24 hours Optional Self-Test/Self-Diagnostic circuitry -BC option adds ease of access battery compartment with polarity sensitive connector INPUT V. AMPS. MAX. WATTS 120 0.028 2.30 277 0.028 2.2 120 0.023 2.30 277 0.028 2.2 MATCHING INDOOR REMOTE FIXTURES WHITE DOUBLE 120 0.04 3.7 277 0.04 4.0 120 0.035 3.7 277 0.04 4.0 • • • • EVHCR2 Maintenance Mode Power Consumption 120 VAC - 0.32W; 277VAC - 0.36W The EVHC Series meets proposed California Energy Commission(CEC) requirements for limits on power consumption in maintenance mode with less than 0.5 watts. EVHC-LED 7.375" 11" 394 3.25" -BC option EVE LED Emergency Exit Sign FEATURES • • • • • • EXIT SIGNS • Compact LED based EXIT sign for wall, ceiling or end mounting Matching Family Appearance Bright and even EXIT panel illumination AC only or 90 minute panel illumination in the event of power outage Environmentally friendly, long life-cycle Nickel Metal Hydride battery UL924 Damp Location Listed Long-Life LEDs, 100,000 hours ORDERING INFORMATION EVE MODEL 1 2 3 4 5 6 7 8 FACES U Universal Face LETTER COLOR R Red G Green For use with Spectron self-diagnostic models only For use with AC models only Operates with 24 volt AC or DC fire alarm panels For emergency illumination of sign from remote 6-24 VDC power source -DC option may not be specified with -2C or -FAP options - AF,-FM and -FAP options may not be specified together See page 2 for special wording options Special worded sign ships as a universal single or double face FINISH W White B Black 7 OPERATION Blank Standard Model E Emergency SELF DIAGNOSTICS Blank None I Spectron® Self-diagnostic 6 OPTIONS 2C FAP FM AF DC 24K 2 circuit operation 2, 5 Fire Alarm Panel 1,3,5,6 Flasher Module 1,6 Audible Flasher 1,6 Remote DC Operation 2,4,6 220-240VAC 50,60Hz with Spectron® SW Special Wording7,8 MATCHING FAMILY FIXTURES 5 .25 MODEL DESCRIPTION EV Unit 2 LED Indoor Emergency Light EVC Exit Sign/ LED Emergency Light ACCESSORIES MODEL DESCRIPTION WGLX WGLXC Wire Guard (Wall Mount) 9.63 Wire Guard (Ceiling Mount) SPECIAL WORDED OPTION SELECTION: MODEL DESCRIPTION SW3 SW4 SW10 SW11 SW13 SW69 IN USE X-RAY IN USE AREA OF REFUGE AREA OF REFUGE WITH WHEELCHAIR AREA OF RESCUE ASSIST. WITH WHEELCHAIR SALIDA 11.5 1.5 * All special worded selections ship as a universal sign for single or double-face application. 395 EVC Architectural LED Combination EXIT/Emergency Light FEATURES • EXIT SIGNS • • • • • • • Compact, Architectural LED based combination EXIT/emergency light for wall, ceiling or end mounting High impact, flame rated and UV stable thermoplastic housing Dual-ratcheting design for full range LED lamp-head positioning Bright and even EXIT panel illumination Environmentally friendly, long life-cycle Lithium Iron Phosphate battery Includes top mount conduit entry Temperature Range: 20°C to 30°C(68°F to 86°F), damp: 10°C to 40°C(50°F to 104°F) UL924 Listed(optional damp location listed) U.S. Patents Pending ORDERING INFORMATION EVC MODEL FACES U Universal Face LETTER COLOR R Red G Green FINISH W White B Black 7 Can only be specified with Spectron® Self-Diagnostics and remote capacity Damp Location Listed not available with EVCURW and EVCUGW base models, standard with all other models 3 No-head option only available on the EVC with remote capacity 4 -24K option only available with Spectron® Self-Diagnostic and remote capacity 5 FAP, FM or AF options may not be specified together 6 Spectron® Self-Diagnostics only available with damp 7 Black finish only available with damp option 1 APPLICATION Blank Standard Model D4 2 LED Remote Capacity D Damp Listed 2 SELF DIAGNOSTICS Blank None I Spectron® Self-diagnostic 6 2 POWER CONSUMPTION AC VOLTAGE HZ. AMPS. WATTS POWER FACTOR 120 277 60 60 0.021 0.017 1.65 2.42 0.65 0.52 No Lamp-heads 3 Fire Alarm Panel 1,5 Flasher Module 1,5 Audible Flasher 1,5 220-240VAC 50,60Hz with Spectron® 4 SINGLE UNIT COVERAGE 1 FC AVERAGE PATH DEPTH (D) PATH WIDTH (W) 16’ 10’ MATCHING REMOTE FIXTURES MODEL DESCRIPTION EVR2 EVO EVR2B VRS3 OPTIONS 0 FAP FM AF 24K 1 FC MINIMUM D 2 LED indoor remote Single or Double head outdoor remote 2 LED Remote with Black Finish Vandal Resistant Shield PATH DEPTH (D) PATH WIDTH (W) 6’ 10’ W ACCESSORIES MODEL DESCRIPTION VRS3 Vandal resistant shield Meets Life Safety Code minimum illuminance of 0.1 fc and average illuminance of 1.0 fc. Assumes open space with no obstructions, mounting height of 7.5', ceiling height of 9' and reflectances of 80/50/20. EVC Photometry files available on the Dual-Lite web site (www.dual-lite.com). ELECTRONICS • • • • 120/277VAC input AC lockout and Low Voltage disconnect Battery re-charge within 24 hours Optional Self-Test/Self-Diagnostic circuitry 9" 12" Overall height with Canopy is 9.8” 396 2.55" EVO EVE Series EVO Outdoor LED Remote R E M OT E H E A D S • • • • • • R E M OT E H E A D S A N D F I X T U R E S FEATURES • Matching LED remote for the Evolution family High performance LEDs Architectural remote specifically for the Evolution family Durable Die-Cast Construction Fully gasketed, waterproof construction Single or Double Lamp-heads Corrosion resistant Black or White finish ORDERING INFORMATION EVO MODEL S Single HEADS FINISH B Black D Double W White CAUTION: The EVO remote can only accept input power from the EV4D, EV4DI emergency lightor EVC-D4 combo with remote capacity. The EVO will not work with any other emergency units. INPUT POWER REQUIREMENTS • 4.8Vdc at 1 watt per head provided exclusively from an EV4D or EV4DI emergency light with remote capacity SPECIFIC LED INFORMATION • • • • Lamp color: Cool white Total lamp output: 88 lumens per head System Efficacy: 80 Lumens per LED Rated LED Lamplife: Greater than 100,000 hrs. EVO OUTDOOR LED REMOTE 4.8" 7.3" 4.2" DIMENSIONAL NOTE Dimensions reflect maximum fixture width and depth. 397 PG Emergency LED Sconce FEATURES EMERGENCY LIGHTING • • • • • • • • Emergency unit for indoor/outdoor architectural applications Sturdy, ADA compliant, vandal-resistant, die-cast aluminum construction Four long-life, 6350K, high-output LEDs configured in redundant pairs Wide area illumination pattern with no heads to aim Maintenance-free nickel-cadmium battery with fully automatic charger Temperature range: 0°C to 50°C (32°F to 122°F), w/heater: -30°C to 50°C (-22°F to 122°F ) UL 924 Wet location Listed U.S. Patent No. D627,916. ORDERING INFORMATION PG MODEL FINISH W White Z Dark Bronze P Platinum OPTIONS HTR Battery Heater Add suffix to model Silver B Black ELECTRONICS • • • • • POWER CONSUMPTION 120/277 60 Hz VAC operation, test switch and LED AC-On indicator light Spectron® self-test/self-diagnostic circuitry Transformer isolation, surge, transient and low voltage disconnect protection Standard electrical box and conduit entry provisions Reverse polarity, short circuit and AC lockout protection MODEL WITHOUT HEATER MODELS WITH HEATER 120VAC 2.78 Watts 120VAC 15.2 Watts 277VAC 2.88 Watts 277 VAC 15.7 Watts Power factor, average: .60 (lagging) Power factor, average: .97 (lagging) MULTIPLE UNIT SPACING SINGLE UNIT COVERAGE Mounting Height: 9' Illuminated Path Depth: 6’ Outdoor Reflectance: 0/30/10 Indoor Reflectance: 80/50/20 Mounting Height: 9' Outdoor Reflectance: 0/30/10 Indoor Reflectance: 80/50/20 D W INDOOR OUTDOOR 1 FC Average (W x D) 33' X 10' 27' X 10' 1 FC Average 1 FC Minimum (W x D) 10' X 10' 9' X 10' 1 FC Minimum 11 7 11 398 7 INDOOR OUTDOOR 44' 33' 16' 15' PGF1 High Performance LED Sconce FEATURES EMERGENCY LIGHTING • • • • • • • • High performance LED wall-pack Sturdy, ADA compliant, vandal resistant, die-cast aluminum construction 7 long life 4300K high output LED’s; 50,000 hours Wide area illumination with no heads to aim Dark Sky Compliant with use of supplied full cut-off shield Available with optional 120VAC photo-control Temperature range of -30˚C to 50˚C(-22˚F to 22˚F) Certified to UL1598 for use in wet locations U.S. Patent No. 0627,916 EMERGENCY LIGHTING • ORDERING INFORMATION PGF1 MODEL FINISH Z Dark Bronze OPTIONS PC1 120VAC Photo-control P Platinum Silver INPUT POWER REQUIREMENTS • 17.7 watts at 120/277VAC SPECIFIC LED INFORMATION • • • Lamp color: Cool white, 4300K Total lamp output: 1067 lumens LED Lamplife: 50,000 hrs. 7 11 7 11 399 PGN High Performance LED Sconce FEATURES EMERGENCY LIGHTING • • • • • • • • • Normally-on sconce for indoor/outdoor architectural applications Compatible with remote DC input for emergency operation on same circuit Sturdy, ADA compliant, vandal-resistant, die-cast aluminum construction Four long-life, 4000K, high-output LEDs configured in redundant pairs Wide area illumination pattern with no heads to aim Dark sky compliant with use of supplied full cutoff shield Temperature range: -30°C to 50°C (-22°F to 122°F) UL 924 Wet location Listed U.S. Patent No. D627,916. ORDERING ORDERING INFORMATION INFORMATION PGN MODEL FINISH W White Z Dark Bronze P Platinum Silver B Black ELECTRONICS POWER CONSUMPTION AC • DC 120 VAC 17 Watts 6 VDC 12 Watts 277 VAC 17 Watts 12 VDC 12.5 Watts Power factor, average: .80 (lagging) • • • 120/277 60 Hz VAC operation Compatible with switched circuits Transformer isolation, surge, and transient protection Short circuit protection SINGLE UNIT COVERAGE MULTIPLE UNIT SPACING Mounting Height: 9' Outdoor Reflectance: 0/30/10 Indoor Reflectance: 80/50/20 Mounting Height: 9' Illuminated Path Depth: 6’ Outdoor Reflectance: 0/30/10 Indoor Reflectance: 80/50/20 D W 1 FC Average (W x D) 1 FC Minimum (W x D) INDOOR OUTDOOR 35' X 10' 29' X 10' 11' X 10' 1 FC Average 10' X 10' 7 1 FC Minimum 11 7 11 400 INDOOR OUTDOOR 49' 37' 19' 16' PGR High Performance LED Remote EMERGENCY LIGHTING • • • • • R E M OT E H E A D S A N D F I X T U R E S FEATURES • High performance LED remote designed for indoor/outdoor applications Sturdy , ADA compliant, vandal resistant, die-cast aluminum construction Four long-life, high-output 4000K LEDs configured in redundant pairs Design optimized for wide area illumination pattern with no heads to aim 90-minute emergency operation from external 6-12V DC source U.S. Patent No. D627,916 ORDERING INFORMATION PGR MODEL FINISH W White B Black Z Dark Bronze P Platinum Silver INPUT POWER REQUIREMENTS • 12 watts at 6vDC, 13 watts at 12vDC SPECIFIC LED INFORMATION • • • • Lamp Color: Neutral White, 4000K Color Rendering Index (CRI): 75 Total Lamp Output: 445 Lumens min. Initial LED Lamplife: 48,000 hrs. at 70% of Initial 7 11 7 11 401 DYN NEMA4X LED Emergency Light FEATURES EMERGENCY LIGHTING • • • • • • • • • U.S. Patents Pending I ndustrial LED based emergency light for wall or ceiling mount application High impact gray finish housing in ABS thermo-plastic, covers and shield in polycarbonate Fully adjustable high output LED lamp-heads with locking feature Food Processing option(FP) includes shield over lamp-heads Environmentally Friendly, Long-Life Lithium Iron Phosphate Battery Continuous Lumen Output over the full 90 minute discharge requirement Includes conduit entry through top center and both sides Temperature Range: Wet/NEMA4X 10°C to 50°C(50°F to 122°F), Heater Option: -30°C to 50° (-22°F to 122°F) Listed to UL924, Wet Location and NEMA4X/IP66 Certified ORDERING INFORMATION DYN MODEL SELF DIAGNOSTICS Blank No Self-Diagnostics I Spectron® Self-Diagnostics CAPACITY 6 6 Watts2 12 12 Watts3 Only available on EVHC with 12 watt capacity DYN6 only available in the following configurations-DYN6, DYN6I, DYN6-4X, DYN6I-4X, DYN6I-4X-HTR, DYN6I-4X-FP, DYN6I-4X-HTR-FP 3 DYN12 only available in the following configurations-DYN12, DYN12I, DYN12-4X, DYN12-4X-FP, DYN12I-4X, DYN12I-4X-HTR, DYN12I-4X-FP, DYN12I-4X-HTR-FP, DYN12-06L, DYN12I-06L, DYN12-4X-06L, DYN12-4X-FP-06L, DYN12I-4X-06L, DYN12I-4X-HTR-06L, DYN12I-4X-FP-06L, DYN12I-4X-HTR-FP-06L 4 FP option must be ordered with 4X option. Example: DYN6I-4X-FP 5 HTR option only available with Spectron 1 APPLICATION Blank Wet Location 4X NEMA4X/IP66 rated FP Food Processing Rated4 2 INPUT POWER CONSUMPTION DYN6 DYN6 with heater CURRENT • 120 0.03 3.40 • 277 0.04 3.49 • 120 0.18 20.94 277 0.08 21.13 120 0.05 5.98 277 0.04 6.52 120 0.21 25.30 277 0.09 25.60 • • • Temp5 1 20 through 277VAC input at 50/60Hz with Intelligent 2 wire input connection AC lockout and Low Voltage disconnect Battery re-charge within 24 hours Optional Self-Test/Self-Diagnostic circuitry Optional Heater Circuitry Optional remote capacity to run matching remote heads 6.04 DIMENSIONS 9.78 DYN12 HTR Heater for Cold ELECTRONICS MAXIMUM WATTAGE INPUT VOLTS OPTIONS Blank 3 Watt lamps 06L 6 Watt LED lamps1 9.78 4.25 1.24 DYN12 with heater 5.15 11.25 11.61 Maintenance Mode Power Consumption 120 VAC - 0.33W; 277VAC - 0.36W 4.34 MATCHING REMOTE FIXTURE REMOTE HEADS 3.54 5.15 DYNRS-4X NEMA4X Rated Single Head Remote DYNRD-4X 10.54Rated NEMA4X Double Head Remote DYNRS-4X-FP Food Processing rated Single Head Remote DYNRD-4X-FP 3.72Head Food Processing rated Double Remote 9.78 9.78 10.54 9.78 9.78 4.94 4.94 3.72 11.25 11.25 11.61 11.61 4.34 4.34 6.3 6.11 5.15 5.15 402 9.75 11.04 10.54 10.54 9.7510.54 10.54 11.04 4.94 4.94 DYNR NEMA4X LED Remote • • • • • R E M OT E H E A D S A N D F I X T U R E S FEATURES Matching LED remote for the DYN series Available in wet/NEMA4X or food processing option Food processing option adds a shield Single or double lamp-head Designed for -22°F to 122°F (-30°C to 50°C) ORDERING INFORMATION DYNR 4X MODEL HEADS S D Single Double OPTIONS APPLICATION Blank FP 4X NEMA4X Food Processing Rated with Shield 6.04 9.78 9.78 4.25 1.24 with remote capacity. The DYN remote will not work CAUTION: The DYN remote can only accept input from the DYN emergency light correctly with input from any other unit. 5.15 INPUT POWER REQUIREMENTS •11.25 12.8vdc 11.61 at 3 watts per head provided exclusively from a DYN12 or DYN12I with remote capacity SPECIFIC LED INFORMATION • • • Lamp color: Cool white, 5000K Total lamp output: 331 lumens per lamp Rated LED Lamplife: Greater than 100,000 hrs. 4.34 3.54 5.15 OPTIONAL FOOD PROCESSING WITH SHIELD DIMENSIONS DIMENSIONS 10.54 10.54 4.94 4.94 3.72 6.3 3.72 6.3 6.11 9.75 11.04 9.75 11.04 403 HLEBS Hazardous Location Emergency Light FEATURES EMERGENCY LIGHTING • • • • Hazardous location LED based emergency lighting system Copper free(less than 0.4%) aluminum housing with a baked on electro-statically applied epoxy Long-life Nickel Cadmium batteries Integral Push-To-Test switch and AC indicator ORDERING INFORMATION HLEBS MODEL 23DH P CAPACITY 23DH 23 Watts with two heads for 90 min TEST OPTIONS P Integral PTT on Enclosure T TIME DELAY T 15 Min Time Delay (120 or 277VAC) LAMP-HEAD OPTIONS N A BG BE CG CE D EG EE DIRECT MOUNT CONFIGURATION EXAMPLES A- HK Heads Attached BE-EL Heads and Exit Acc. CG-HK and EL Heads 404 No heads - For Remote Heads Ordered Separately 2 HLEBSHK1030 Heads Factory Attached 2 HLEBSEL1030 Heads with Guards and Fittings for Attachment 2 HLEBSEL1030 Heads with 1 Guard and 1 HEXA-100 EXIT and Fittings for Attachment 1 HLEBSHK1030 Heads Attached and 1 HLEBSEL1030 Head with Guard and Fittings for Attachment 1 HLEBSHK1030 Heads Attached and 1 HLEBSEL1030 Head with HEXA-100 EXIT and Fittings for Attachment 1 HLEBSHK1030 Only (2nd Head Remote - Ordered Separately) 1 HLEBSEL1030 Only with Guard and Fittings for Attachment (2nd Head Remote - Ordered Separately) 1 HLEBSEL1030 Only with HEXA100 EXIT and Fittings for Attachment (2nd Head Remote - Ordered Separately) HLEBS Hazardous Location Emergency Light FEATURES • • • The EL and HK heads are available for indirect remote mounting and are used in conjunction with the HLEBS housing/charger assembly designed to run 2 heads max. All remote heads are hazardous location listed All heads are 30VDC input with 10W load EL heads offer 1021 lumens and HK heads offer 905 lumens initial output EMERGENCY LIGHTING • Pendant INDIRECT MOUNT CONFIGURATION EXAMPLES (ORDERED SEPARATELY) Pendant Wall Ceiling EL Remote Heads 10W 30VDC Pendant 3⁄4” Ceiling 3 ⁄4” Wall 3 ⁄4” With Guard HLEBSEL1030A2G HLEBSEL1030X2G HLEBSEL1030B2G Without Guard HLEBSEL1030A2 HLEBSEL1030X2 HLEBSEL1030B2 Classification: CID1CD; CIID1EFG HK Remote Heads 10W 30VDC EBSHK1030-RFSC HK Head with Adjustable Factory Sealed “C” fittings set HLEBSHK1030-RFSC HK Head with Adjustable Factory Sealed “L” fittings set HLEBSHK1030-RFSL Classification: CID1D; CIID1EFG EBSHK1030-RFSL DIMENSIONS LUMINAIRE ACCESSORIES MODEL DESCRIPTION HEXA-100 Exit Accessory 13.75 ” 13.75 ” 14.5 ” 14.5 ” 14.5 ” 7.38” 12.13” 16 ” 10.5 ” 10.5 ” 10.5 ” 75 EMG1 Globe Guard EMG1R Red Globe Guard 14” 7.5 ” Pendant 1” 11.5” 14.5 ” 7.5 ” 7” 7” 7.75” Wall Ceiling 7.38” 12.13” 7.38” 7.38” 3.75 14” 8” 3.75 3.75 6” 14” 14” Standard Dome 7” 7” 1” 12.13” Exit Sign 11.5” 12.13” 12.13” ERSD15 Dome Reflector ERA15 Angle Reflector 7.75” 1” 1” Exit Accessory 8” 6” 12.13” 7” 7” 7” 7” 11.5” 11.5” Angled 7.75” 7.75” 8” 8” 6” 6” 405 LE Recessed Mounting Edge-Lit LED Exit Sign FEATURES • • EXIT SIGNS • • • • • • • ORDERING INFORMATION LE MOUNTING C Ceiling mount W Wall mount E End mount MODEL FACES S Single D Double* LETTER COLOR R Red G Green *Not for use with wall mounted models. DIRECTIONAL ARROWS X R L D No arrows EXIT Right arrow* EXIT> Left arrow* <EXIT Double arrows <EXIT> C L/R arrows** <EXIT/EXIT> FINISH N Satin W C B S Z Aluminum White Chrome Black Satin brass Dark Bronze *Not for use with double face models. Use “C” L/R arrow designator ** Double face models only. Provides reversible right or left arrow indicator POWER CONSUMPTION MODEL Red AC Only Green AC Only Red Emergency Green Emergency ACCESSORIES SINGLE FACE DOUBLE FACE 2.2W 2.5W 3.3W 3.6W 3.7W 4.4W 4.7W 5.2W Wattage figures include LED lamps, transformers and electronics power requirements. Power factor, average: .80 (lagging) MODEL DESCRIPTION For use with AC models only. Rough-in kit may not be ordered separately on models specified with -24K option. c Must be ordered in conjunction with -2C option on exit sign. To Order Rough-In Kit Separately To order rough-in kit only for early installation, add “-XK” option suffix to exit model number and order “URK” or “URK2C” kit separately. • • • 406 SW 2C FAP FM AF DC 24K XK W M 8L b Transformer isolation, surge, transient, and low voltage disconnect protection 90 minute emergency operation Reverse polarity, short circuit and AC-lockout protection 120/277VAC 60Hz operation, test switch and LED AC-On indicator light SELF-DIAGNOSTIC Blank None I Spectron self-testing/ self-diagnostic electronics* OPTIONS MODEL a • OPTIONS See “Options” section *For use with emergency models only. URK Universal rough-in kit URK2C Universal 2-circuit rough-in kit a,b,c ELECTRONICS OPERATION A AC only E Emergency DESCRIPTION Special Wording 12 2-circuit operation 2,5 Fire alarm panel interface 3,5,6 Flasher module 1,6 Audible/Flasher module 1,6 Remote DC Operation 2,4,5 220-240VAC, 60 Hz. operation 9 Recessed mount exit sign less rough-in kit 7,9 White plaque background Mirror plaque background 8 8 inch letter plaque (red letters only) 10,11 For use with emergency models only. For use with AC models only. 3 Operates with 24-volt AC or DC fire alarm panels. 4 For emergency illumination of sign from remote 6-24 VDC power sources. 5 -DC option may not be specified with -2C or -FAP options. 6 -AF, -FM and -FAP options may not be specified together. 7 Allows ordering of rough-in kit separately for recessed mount (LE) models. See “Accessories”. 8 For use with single face models only. Standard on double face models. 9 Rough-in kit may not be ordered separately on models specified with -24K option. 10 LE exit models with 8" plaques registered under NYC-BEC Calendar Number 42135 for use in New York City. 11 Single face LE exit signs specified with the -8L option are supplied without backgrounds. Double face models specified with the -8L option are supplied with mirror backgrounds. 12 Enter Special Wording choice from page 963: example: SW41. Special wording option not available with 8" letter plaque. Some special wording signs not available with directional arrows. 1 2 EXIT SIGNS • Edgelit exit sign for recessed mounted architectural and commercial applications Clear, injection molded, dual plaque acrylic with clear, white or mirror backgrounds High strength, extruded aluminum housing in multiple finishes Energy saving, long-life LED lamps exceeds brightness and uniformity requirements Custom printed, silk screened chevron arrows; 6" letters with ¾" stroke End/ceiling/wall mount and included die-cast aluminum canopy Maintenance-free nickel-cadmium battery with fully automatic charger Temperature range: 20°C to 30°C (68°F to 86°F) UL 924 Wet Location Listed Special Worded signs certified to UL48-Electric Signs SEMPRA SE ® Die-cast Exit Sign FEATURES • • • • • • • • MODEL SE (Surface) SEMR (Master/Remote) SERS (Recessed) FACES S Single D Double LETTER COLOR R Red G Green OPERATION Blank AC only E Emergency Brushed Face WN White with Brushed Face MODEL • DESCRIPTION Special Wording 2-circuit operation (2)(5) Fire alarm panel interface (1)(3)(5)(6) Flasher module (1)(6) Audible/Flasher module (1)(6) Remote DC operation (2)(4)(5) 220-240VAC, 60 Hz. operation Vandal/tamper resistant option(8) Sign assembly less rough-in back box – SERS only (7) • • • • Transformer isolation, surge, transient, and low voltage disconnect protection Pre-stripped pigtail leads with push in wiring connectors 120 minute emergency operation 120/277VAC 60Hz operation, test switch and LED AC-On indicator light Reverse polarity, short circuit and AC lockout protection Rough-In Back Box 9 1/8” 120VAC 277VAC 2.6W 2.1W 3.8W 3.5W 2.6W 2.1W 3.8W 3.5W Wattage figures include LED lamps, transformers and electronics power requirements. LED lamp assemblies (red or green) consume less than 1 watt. Power factor, average: .8 (lagging) 12 3/8” (31.4 cm) 10” (25.5 cm) SE or Master Sign MODEL Red AC Only Green AC Only Red Emergency Green Emergency MODEL DESCRIPTION (23 cm) 1 5/8” testing/selfdiagnostic electronics VRS-3 Vandal resistant shield FCM-R Kit converts AC red letter models to emergency operation FCM-G Kit converts AC green letter models to emergency operation PMCW 12½" Pendant mounting kit (white) PMCB 12½" Pendant mounting kit (black) WGLX Wire guard (Wall mount) WGLXC Wire guard (Ceiling mount) WGLXE Wire guard (End mount) RBB Rough in back box kit SERS or Remote Sign (4.14 cm) OPTIONS See “Options” section ACCESSORIES (1) For use with Spectron® self-diagnostic models only. (2) For use with AC models only. (3) Operates with 24-volt AC or DC fire alarm panels. (4) For emergency illumination of sign from remote 6-24 VDC power sources. (5) -DC option may not be specified with -2C or -FAP options. (6) -AF, -FM and -FAP options may not be specified together. (7) Enter Special Wording choice from page 959: example SW10. Not available with SEMR or SERS models. (8) Provides polycarbonate face shield and tamper-proof screws. Meets UL listing requirements for floor proximity use. 11 3/4” (30 cm) 12 5/8” (32 cm) SELF-DIAGNOSTIC Blank None I Spectron self- POWER CONSUMPTION ELECTRONICS OPTIONS SW 2C FAP FM AF DC 24K VTR LRBB FINISH W White B Black BN Black with EXIT SIGNS • Die-cast aluminum exit sign for commercial or light industrial applications Master/remote - SEMR (2 sign set) and recessed - SERS models available Universal end/ceiling/wall mount and included die-cast aluminum canopy Energy saving, long-life LED lamps exceed brightness and uniformity requirements Completely concealed break out chevron arrows; 6" letters with ¾" stroke Maintenance-free nickel-cadmium battery with fully automatic charger Temperature range: 0°C to 40°C (32°F to 104°F) UL 924 Listed; UL 924 Damp Location Listed (SE models only) U.S. Patent No. 6,050,013 and 6,082,031 /8” 5 (1.6 cm) 9 5/8” (24.4 cm) 407 LE, LES, SE SPECIAL WORDING Special Worded Sign SE SEMPRA® SERIES SPECIAL WORDED SIGNS EXIT SIGNS EXIT SIGNS Dual-Lite's cast-aluminum SE Series exit signs feature an option for custom or standard special-wording. The images below represent a sample of standard special-worded signs available. Please review the SE Series specification sheet for a complete list of standard special-worded signs or contact the factory to request your custom special-worded sign. SW65 (Makhraj Arabic) SW10 SW13 SW40 SW47 SW5 SW101 SW7 SW97 SW22 SW31 SW45 SW37 SW98 SW9 SW30 SW69 SW48 SW73 SW4 LE/LES SERIES SPECIAL WORDED SIGNS LES Series architectural surface-mounted LED edge-lit exit signs feature an option for standard or custom specialwording. The images below represent standard special-worded signs available for the LES Series. The artwork and silkscreening for the standard signs shown below were previously developed therefore pricing for these special-worded signs do not incur a setup charge. If your special-worded requirements do not appear on this page, please contact the factory to request your custom special-wording sign. Custom special wording signs incur a one time set-up charge for each development. STANDARD SPECIAL WORDING SIGNS WITH DIRECTIONAL ARROWS SW118 SW41 (Arabic/Exit) SW13 SW10 SW69 SW11 STANDARD SPECIAL WORDING SIGNS WITHOUT DIRECTIONAL ARROWS 408 SW4 SW3 SW31 SW2 SEWL Wet Location/NEMA 4X Die-cast Exit Sign FEATURES • • • • • • • • • EXIT SIGNS • Exit sign for wall mounting in harsh applications or industrial environments Heavy-gauge, corrosion resistant and gasketed die-cast aluminum housing Spectron® self-test/self-diagnostic circuitry Vandal resistant polycarbonate shield, with tamper resistant stainless steel screws Universal end/ceiling/wall mount and included die-cast aluminum canopy Energy saving, long-life LED lamps exceed brightness and uniformity requirements Completely concealed break out chevron arrows; 6" letters with ¾" stroke Maintenance-free, nickel-cadmium battery with fully automatic charger Temperature range: -30°C to 50°C (-22°F to 122°F) Certified to UL 924 Wet Location Standards; optional IP66; Nema 4X rating ORDERING INFORMATION SEWL MODEL FACES S Single D Double LETTER COLOR R Red G Green FINISH B Black W White OPERATION Blank AC Only E Emergency OPTIONS HTR Internal heater 1 4X NEMA 4X rating 2 1 For use with emergency models only. 2 Heater comes standard with 4X option on emergency models. POWER CONSUMPTION ELECTRONICS • • • • • Transformer isolation, surge, transient, and low voltage disconnect protection Pre-stripped pigtail leads with push in wiring connectors 90 minute emergency operation Reverse polarity, short circuit and AC lockout protection 120/277VAC 60Hz operation, test switch and LED AC-On indicator light MODEL Red AC Only Green AC Only Red Emergency Green Emergency 120VAC 277VAC 2.6W 2.1W 8.7W 8.3W 2.6W 2.1W 8.4W 8.1W Wattage figures include LED lamps, transformers, heaters with emergency models and electronics power requirements. LED lamp assemblies (red or green) consume less than 1 watt. Power factor, average: .95 (lagging) 5¼" Square Single Face 3" Deep Double Face 3½" Deep Single Face NEMA 4X 3¾" Deep 103⁄16" 97⁄16" 1411⁄16" 157⁄16" 409 UFO-LED UFO-LED LED Battery Pack LED Battery Pack FEATURES FEATURES Battery pack with 120/277 VAC 60Hz inverter output to power driver for an LED • luminaire • Battery pack with 120/277 VAC 60Hz inverter output driver/LED at full lumen output for 90 minutes • • Can bebeused Can usedwith withswitched switchedororunswitched unswitchedluminaires luminaires • • Installation Installationmay maybebewithin, within,ororremote remotefrom fromthe theluminaire; luminaire indoor installation for indoor or outdoor luminaires Indoor installation for indoor or outdoor luminaires 120/277 VAC 60 Hz input operation, remote test switch with AC-On indicator light 120/277 VAC 60 Hz input operation Temperature range: 0˚C to 50˚C (32˚F to 122˚F) • Remote test switch with AC-On indicator light UL 924 Damp Location Listed • Temperature range: 0°C to 45°C (32°F to 113°F); 20VA/W only for 45°-50°C (113°-122°F) • UL 924 Damp Location Listed • • • • • ORDERING INFORMATION ORDERING INFORMATION U LED UFO-LED MODEL MODEL UFO-LED 25 20 OUTPUT VA/W CAPACITY 20 25 VA/W ACCESSORIES ACCESSORIES SPECIFICATIONS SPECIFICATIONS MODEL DESCRIPTION DESCRIPTION MODEL SPRTS Remote test test switch switch/charge /chargeindicator indicatormodule module1 1,2 11 2 Fits single-gang single-gang box box Fits Comes standard; additional may be ordered CATALOG NUMBER CATALOG NUMBER INPUT WATTAGE INPUT WATTAGE MAX. LOAD VA/W MAX. LOAD VA/W F PF) (UNITY LAMP TYPETYPE LAMP UFO-LED25 UFO-LED25 9.59.5 25 25 LEDLED UFO-LED UFO-LED25 SPRTS (included remote test switch with charging indicator) UFO-LED25 SPRTS (INCLUDED REMOTE TEST SWITCH WITH CHARGING INDICATOR) 0.2” (5mm) 2.85" 2.8" 4.55” (116mm) 16.6" 978 410 2.75” (70mm) BAT T E RY PAC K S BAT BAT T E RY KS KS T EPAC RY PAC • • Sealed Sealednickel-cadmium nickel-cadmiumbattery; battery powers LPS Central Lighting Micro Inverters FEATURES • • • • • • M I C R O I N V E RT E R • AC output provides full lumen output for emergency lighting loads in commercial or industrial applications Compatible with incandescent, LED, compact and linear fluorescent lamps White painted steel enclosure Offline operation for greater efficiency Maintenance-free Lead-Calcium or Nickel-Cadmium batteries Temperature range: 20°C to 30°C (68°F to 86°F) UL 924 Listed ORDERING INFORMATION LPS CAPACITY 20 20 VA/W 1 32 32 VA/W 2 35 35 VA/W 1 55 55 VA/W 2 MODEL MOUNTING S Surface Wall R Recessed Wall T Recessed Ceiling T-Grid Surface Mount Housing 1 Nickel-Cadmium battery type 2 Lead Calcium battery type ELECTRONICS SPECIFICATIONS LPS32 LPS55 LPS20 LPS35 INPUT/ OUTPUT VOLT MAX INPUT (A) 120V 0.34 277V 0.15 120V 0.54 277V 0.23 120V 0.25 277V 0.11 120V 0.37 277V 0.16 WEIGHT WITH BATTERIES POWER RATING (VA/W) 14lbs. 32 18lbs. 55 TEMP. RANGE 20°C -30°C 11lbs. SYSTEM DC VOLTAGE RECHARGE TIME (HR) 12 20 96 TEST AC CHG INV PUSH ON ON ON ACCESSORIES 8.88” ORDER SEPARATELY RTSLP 12lbs. 7.38” Operates with normally-on, normally-off and switched loads • AC lockout and Low Voltage Battery disconnect • Brownout 14.75” Protection: Automatically transfers to emergency 4.38” 3.13” power (models (models • Overload and Short Circuit Protection: Protects AC and DC LPS-20 LPS-35 • Charger Type: Temperature compensated, dual-mode & LPS-32 ) & LPS-55) Recessed Mount Housing • LED status indicator and push button test switch • Load can be up to 1000 feet away • 35 Remote Test Switch for LPS 16.25” Surface Mount Housing Ceiling T-grid Mount Housing .50 Extrusion from wall after installation 4.75” 8.56” 8” 7.38” 23.88” 14.75” Recessed Mount Housing TEST AC CHG INV PUSH ON ON ON 4.38” 3.13” (models LPS-35 & LPS-55) (models LPS-20 & LPS-32 ) 6.19” 8.88” 16.25” Ceiling T-grid Mount Housing .50 Extrusion from wall after installation 4.75” 411 8.56” 8” LG Single-Phase Central Lighting Inverter FEATURES • • • • • • ORDERING INFORMATION LG MODEL CAPACITY 1 100 VA/W 2 250 VA/W2 MOUNTING S Surface Wall Mounting T Recessed Ceiling Mounting1 SELF DIAGNOSTICS Blank None I Spectron Self-test/Selfdiagnostic Electronics3 Only available on 100 VA/W models Housing (LG2SLB) and batteries (0120935) ship in separate cartons 3 Only available on 250 VA/W models 1 2 LG1S with TRMLG Trim Plate LG1T LG1S SPECIFICATIONS ELECTRONICS BASE CATALOG NUMBER FORM AND FIT WEIGHT (LB) WITH BATTERIES POWER RATING(VA/W) POWER FACTOR MAXIMUM INPUT CURRENT (A) SYSTEM DC VOLTAGE RECHARGE TIME(HR) LG1S Wall Mount Surface 43 100 0.8 lead to 0.75 lag 120 VAC: 1.02 A 277 VAC: 0.47 A 12 48 LG1T Ceiling Mount Recessed T-grid 45 100 0.8 lead to 0.75 lag 120 VAC: 1.02 A 277 VAC: 0.47 A 12 48 LG2S Wall Mount Surface 78 250 0.8 lead to 0.7 lag 120 VAC: 2.5 A 277 VAC: 1.1 A 24 72 • • • • • • Interruptible design; automatically transfers in 2 seconds or less Load can be up to 1,000 feet away Temperature compensated battery charger Operates with normally-on, normally-off and switched loads LVD, AC lockout, short circuit, current limiting, overload and brownout protection LED status indicator and push button test switch ACCESSORIES MODEL DESCRIPTION WGTW Wire Guard for LG1S RTSLG Remote Test Switch for LG2S TRMLG Recessed Mount Trim Plate for LG1S; Refer to existing specification sheet 412 I N V E RT E R S I N V E RT E R S • AC output provides full lumen output for emergency lighting loads in commercial or industrial applications Compatible with incandescent, LED, compact and linear fluorescent lamps White painted steel enclosure Offline operation for greater efficiency Maintenance-free lead-calcium batteries Temperature range: 20°C to 30°C (68°F to 86°F) UL 924 Wet Location Listed LG Single-Phase Central Lighting Inverter LG1S Wall Mount Surface Model I N V E RT E R S 4.313" 5.5" 5.5"5.5" I N V E RT E R S 4.313" 14.188" 14.188" 5.5" 23.875" 18.125" 18.125" 4.313" 14.188" 5.5" 5.5" 10.563" LG1T Recessed T-Grid Ceiling Mount Model 23.875" 23.875" 18.125" 5.75" 10.563" 10.313" 10.125" 23.875" 23.875" 7" 5.75" 14.189" LG1S with Wall Mount Recessed Trim Plate 14.189" 10.313" 10.563" .625" .625" 10.125" 18.343" 23.875" 5.75" 7" 10.200" 18.125" 21.689" 18.125" 21.689" 10.313" 10.125" 14.189" .625" 8.563" 18.343" 7" 4.25" 4.25" 10.200" LG2S Wall Mount Surface Model 8.250" 8.563" 18.343" 18.125" 21.689" 18.343" 8.563" 4.25" 10.200" 8.563" 8.250" 18.343" 8.563" 413 DLS Single-Phase Central Lighting Inverter FEATURES • I N V E RT E R S • • • • • • AC output provides full lumen output for emergency lighting loads in commercial or industrial applications Compatible with any lighting load including incandescent, fluorescent, HID and LED lamps Painted steel enclosure Offline operation up to 98% efficient Maintenance-free lead-calcium batteries Temperature range: 20°C to 30°C (68°F to 86°F) UL 924 Listed; Made in USA ORDERING INFORMATION DLS MODEL INPUT/OUTPUT VOLTAGE 120 120VAC 277 277VAC CAPACITY RATING1 400 400 VA/Watts 525 525 VA/Watts 750 750 VA/Watts 1000 1000 VA/Watts 1500 1500 VA/Watts 2100 2100 VA/Watts 1 Output Circuit Breakers: • 400 VA and 525 VA models are supplied with one, 15 amp normally on circuit breaker • 750 VA through 2100 VA models: output circuit breakers are optional OUTPUT CIRCUIT BREAKER VOLTAGE RATING A 120VAC B 277VAC OUTPUT CIRCUIT BREAKER TYPE Blank N Normally-On Normally-Off2 A maximum of 4, normallyoff circuit breakers may be specified. Maximum rating of normally-off circuit breakers is 20 amperes. Normally-off circuit breakers include a built-in, 15-minute retransfer delay to accomodate HID lighting loads 2 OUTPUT CIRCUIT BREAKER AMPERE RATING 15 15 Amperes 20 20 Amperes 25 25 Amperes 30 30 Amperes OUTPUT CIRCUIT BREAKER QUANTITY 01 1 circuit breaker 02 2 circuit breakers 03 3 circuit breakers 04 4 circuit breakers 05 5 circuit breakers 06 6 circuit breakers 07 7 circuit breakers 08 8 circuit breakers 09 9 circuit breakers 10 10 circuit breakers ELECTRONICS • • • • • • Uninterruptible “no break” transfer Microprocessor controlled pulse width modulation (PWM) using IGBT technology LVD, short-circuit, current limiting and overload protection True sine wave output Power factor range of 0.8 lead to 0.75 lag LED status indicator, audible alarm system and push button test switch 400VA to 525VA Models (may be wall mounted) 414 750VA to 2100VA Models (floor mount only) OUTPUT CIRCUIT BREAKER SUPERVISION Blank Monitored U Unmonitored3 3 A maximum of 6 monitored or 10 unmonitored normally on circuit breakers may be specified 415 COMPASS Offers products such as emergency lighting units and exit signs for the commercial and institutional market place. Compass provides value engineered-product without sacrificing performance. 416 CU2 LED Emergency Light FEATURES EMERGENCY FLOODLIGHTS • • • • • • • Emergency unit for commercial applications UV stable thermoplastic white or black housing available Quick installation with fully adjustable lamp-heads LED Lamps with a life-cycle of more than 10 years Dual-voltage 120 or 277V AC input Remote capacity or extended runtime option Long-life Nickel Cadmium battery with fully automatic charger UL 924 Damp Location Listed EMERGENCY LGIHTING • ORDERING INFORMATION CATALOG NUMBER CU2 DESCRIPTION White Thermoplastic, Dual-Head LED Emergency Light , 120/277 Input, Damp Location Listed, 3 VDC, 1 Watt CU2B Black Thermoplastic, Dual-Head LED Emergency Light, 120/277 Input, Damp Location Listed, 3 VDC, 1 Watt CU2RC White Thermoplastic, Dual-Head LED Emergency Light, 120/277 Input, Damp Location Listed, Remote Capacity, 3 VDC, 1 Watt CU2RCB Black Thermoplastic, Dual-Head LED Emergency Light, 120/277 Input, Damp Location Listed, Remote Capacity, 3 VDC, 1 Watt Note: Remote Capacity Unit will only power the Compass Indoor and Outdoor Remote(CIR and COR Series) MATCHING REMOTE FIXTURES MODEL DESCRIPTION CIR LED Indoor Remote Heads COR LED Outdoor Remote Heads ACCESSORIES CU2B MODEL DESCRIPTION WGLZ Wireguard- 6.25” H X 14” W X 4” D ELECTRONICS • • 90 minute emergency operation Test switch and LED AC-on indicator light Single Carton Weight: 1 lbs. Master Carton Quantity: 12 each C IRD C IRS C 0RS C 0RD 417 CE LED Emergency Exit Sign FEATURES • EXIT SIGNS • • • • • • Exit sign for commercial applications UV stable thermoplastic white or black housing available Long life LED lamps provide bright, even illumination Universal end or ceiling mount Dual-voltage 120 or 277V AC input Remote capacity or extended runtime option Long-life Nickel Cadmium battery with fully automatic charger UL 924 Damp Location Listed EXIT • ORDERING INFORMATION CATALOG NUMBER CER DESCRIPTION White Thermoplastic Exit, Universal Face, Red LED Emergency Exit CERB Black Thermoplastic Exit, Universal Face, Red LED Emergency Exit CEG White Thermoplastic Exit, Universal Face, Green LED Emergency Exit CEGB Black Thermoplastic Exit, Universal Face, Green LED Emergency Exit CERRC White Thermoplastic Exit, Universal Face, Red LED Emergency Exit,Remote Capacity CERRCB Black Thermoplastic Exit, Universal Face, Red LED Emergency Exit,Remote Capacity CEGRC White Thermoplastic Exit, Universal Face, Green LED Emergency Exit, Remote Capacity Note: Remote Capacity Unit will only power the Compass Indoor and Outdoor Remote(CIR and COR Series) 12.6”12.6” MATCHING REMOTE FIXTURES MODEL DESCRIPTION CIR LED Indoor Remote Heads COR LED Outdoor Remote Heads ACCESSORIES MODEL DESCRIPTION WGLX Wall Mount Wireguard- 10” H X 14” W X 2.25” D CEGB ELECTRONICS • • 90 minute emergency operation with 1 double or 2 single remotes Test switch and LED AC-on indicator light C IRD CIR S C 0RS C0RD 418 Single Carton Weight: 2 lbs. Master Carton Quantity: 6 each CC Combination LED Exit/Light FEATURES • • EXIT • • • • • EXIT SIGNS • Combination unit for commercial applications UV stable thermoplastic white or black housing available Long life LED lamps in exit sign rated at 50,000 hour life expectancy LED Lamps with a life-cycle of more than 10 years Dual-voltage 120 or 277V AC input Remote capacity or extended runtime option Long-life Nickel Cadmium battery with fully automatic charger UL 924 Damp Location Listed ORDERING INFORMATION CATALOG NUMBER DESCRIPTION CCR White Thermoplastic, Combination Exit/Emergency Light, Universal Face, Red Letters CCRB Black Thermoplastic, Combination Exit/Emergency Light, Universal Face, Red Letters CCG White Thermoplastic, Combination Exit/Emergency Light, Universal Face, Green Letters CCGB Black Thermoplastic, Combination Exit/Emergency Light, Universal Face, Green Letters CCRRC White Thermoplastic, Combination Exit/Emergency Light, Universal Face, Red Letters, Remote Capacity CCRRCB Black Thermoplastic, Combination Exit/Emergency Light, Universal Face, Red Letters, Remote Capacity CCGRC White Thermoplastic, Combination Exit/Emergency Light, Universal Face, Green Letters, Remote Capacity Note: Remote Capacity Unit will only power the Compass Indoor and Outdoor Remote(CIR and COR Series) MATCHING REMOTE FIXTURES MODEL DESCRIPTION CIR LED Indoor Remote Heads COR LED Outdoor Remote Heads ACCESSORIES MODEL DESCRIPTION WGEL Wall Mount Wireguard- 8” H X 20” W X 8” D CCGB ELECTRONICS • • 90 minute emergency operation with 1 double or 2 single remotes Test switch and LED AC-on indicator light C IRD C IRS C O RS Single Carton Weight: 2.5 lbs. Master Carton Quantity: 6 each C O RD 419 CIR LED Indoor Remote FEATURES • R E M OT E H E A D S • • • • • Single or Double lamp-head remote with base-plate LED life-cycle of more than 10 years Quick installation Dual-voltage 120 or 277V AC input UL924 Damp Location Listed Fully adjustable lamp-heads ORDERING INFORMATION CATALOG NUMBER CIRS CIRD DESCRIPTION LED Remote, Single Mounting Base, 3 VDC, 1 Watt LED Remote, Double Mounting Base, 3 VDC, 1 Watt Note: Powered by the Compass Exit, Combo or Emergency Light with Remote Capacity CIRS Single Remote Carton Weight: 1 lbs. Master Carton Quantity: 20 each 420 12.6” CIRD Double Remote Carton Weight: 1.2 lbs. Master Carton Quantity: 20 each COR LED Outdoor Remote FEATURES • • • • Single or Double lamp-head remote with base LED life-cycle of more than 10 years Quick installation Fully adjustable lamp-heads Fully gasketed for application in wet environment R E M OT E H E A D S • ORDERING INFORMATION CATALOG NUMBER CORS CORD DESCRIPTION LED Outdoor Remote, Single, Mounting Base, 3 VDC, 1 Watt LED Outdoor Remote, Double, Mounting Base, 3 VDC, 1 Watt Note: Powered by Compass Exit, Combo or Emergency Light with Remote Capacity CORS CORD Single Remote Carton Weight: 1 lbs. Master Carton Quantity: 20 each Double Remote Carton Weight: 1.2 lbs. Master Carton Quantity: 20 each 421 CUW Decorative LED AC/Emergency Light EMERGENCY LIGHT FEATURES • Normally-on and emergency operation • Durable die-cast aluminum housing • Prismatic polycarbonate refractor • 10 year LED life cycle • Long-life Nickel Cadmium battery • Fully sealed and gasketed design • Includes self-diagnostic/self-test • Includes conduit entry at top of unit • Optional heater and photo-cell • Temp. range standard, 0°C to 50°C with heater, -20°C to 40°C • UL924 Wet Location Listed ORDERING INFORMATION CATALOG NUMBER DESCRIPTION CUWZ Die-Cast, Normally on/Emergency, 0° to 50°C, Dark Bronze Finish CUWZ-HTR Die-Cast, Normally on/Emergency, -20° to 40°C, with Heater, Dark Bronze Finish CUWZ-HTR-PC Die-Cast, Normally on/Emergency, -20° to 40°C, with HTR and Photo-Conrol, Dark Bronze Finish 6.54” ELECTRONICS • • • • Universal 100-300VAC input 4.8VDC Nickel Cadmium battery Battery re-charge within 24 hours Fully automatic solid-state charger 10.47” 3.78” Single Carton Weight: 4.0 lbs. Master Carton Quantity: 6 each 422 CCE Thin Die-Cast LED Emergency Exit Sign FEATURES • • • • • • EXIT SIGNS • Thin die-cast aluminum Exit sign for commercial or light industrial applications Painted black housing with brushed aluminum face Long life LED lamps provide bright, even illumination Universal end or ceiling mount with canopy included Dual-voltage 120 or 277V AC input Emergency models include long-life Nickel Cadmium battery UL 924 Damp Location Listed ORDERING INFORMATION CATALOG NUMBER CCESRE DESCRIPTION Die-Cast Exit, Brushed Face, Black Housing, Single-Face, Red Letters, Emergency CCEDRE Die-Cast Exit, Brushed Face, Black Housing, Double-Face, Red Letters, Emergency CCESGE Die-Cast Exit, Brushed Face, Black Housing, Single-Face, Green Letters, Emergency CCEDGE Die-Cast Exit, Brushed Face, Black Housing, Double-Face, Green Letters, Emergency CCESR Die-Cast Exit, Brushed Face, Black Housing, Single-Face, Red Letters, AC CCEDR Die-Cast Exit, Brushed Face, Black Housing, Double-Face, Red Letters, AC CCESG Die-Cast Exit, Brushed Face, Black Housing, Single-Face, Green Letters, AC CCEDG Die-Cast Exit, Brushed Face, Black Housing, Double-Face, Green Letters, AC 12.6” ELECTRONICS • • • 90 minute emergency operation AC or Emergency operation Test switch and LED AC-on indicator light Single Carton Weight: 2.8 lbs. Master Carton Quantity: 8 each 423 CEL Edge-Lit LED Emergency Exit Sign FEATURES • • • • • • • EXIT EXIT SIGNS • Edgelit exit sign for architectural applications Brushed aluminum housing with field installed directional arrows Long life LED lamps provide bright, even illumination Recessed or surface mount with canopy included Mirror divider on single and double-face models Dual-voltage 120 or 277V AC input Emergency models include long-life Nickel Cadmium battery UL 924 listed ORDERING INFORMATION CATALOG NUMBER CELS1RNE DESCRIPTION Edge-Lit Exit, Surface Mount, Single Face, Red Letters, Brushed Aluminum, Battery CELS1GNE Edge-Lit Exit, Surface Mount, Single Face, Green Letters, Brushed Aluminum, Battery CELS2RNE Edge-Lit Exit, Surface Mount, Double Face, Red Letters, Brushed Aluminum, Battery CELS2GNE Edge-Lit Exit, Surface Mount, Double Face, Green Letters, Brushed Aluminum, Battery CELR1RNE Edge-Lit Exit, Recessed Mount, Single Face, Red Letters, Brushed Aluminum, Battery CELR1GNE Edge-Lit Exit, Recessed Mount, Single Face, Green Letters, Brushed Aluminum, Battery CELR2RNE Edge-Lit Exit, Recessed Mount, Double Face, Red Letters, Brushed Aluminum, Battery CELR2GNE Edge-Lit Exit, Recessed Mount, Double Face, Green Letters, Brushed Aluminum, Battery ELECTRONICS • • 90 minute emergency operation with 1 double or 2 single remotes Test switch and LED AC-on indicator light ADDITIONAL MOUNTING OPTIONS Single Carton Weight Surface Mount: 3 lbs. Recessed Mount: 5 lbs. Master Carton Quantity Surface Mount: 6 each Recessed Mount: 3 each 424 Surface Mount Recessed Wall Recessed Ceiling CU2W Wet Location LED Emergency Light FEATURES • • • • • • • • Emergency unit for wet location or light industrial applications UV stable thermoplastic grey housing available Quick installation with fully adjustable lamp-heads LED Lamps with a life-cycle of more than 10 years Dual-voltage 120 or 277V AC input Provided with water-proof test switch and AC-On indicator Remote capacity or extended runtime standard Long-life Nickel Cadmium battery with fully automatic charger UL 924 Wet Location Listed EMERGENCY LIGHTING • ORDERING INFORMATION CATALOG NUMBER CU2WG DESCRIPTION Wet Location LED emergency light, Dual-Head Fully Adjustable, Grey Finish, Remote Capacity, 120/277 Input, 1.9 watts CU2WB Wet Location LED emergency light, Dual-Head Fully Adjustable, Black Finish, Remote Capacity, 120/277 Input, 1.9 watts Note: Unit will only power 1 each Compass CWRD or 2 each CWRS remotes C WR S MATCHING REMOTE FIXTURES MODEL DESCRIPTION CWRS LED Outdoor Remote, Single CWRD LED Outdoor Remote, Double ACCESSORIES MODEL DESCRIPTION WGEL Wireguard- 8” H X 20” W X 8” D ELECTRONICS • • 90 minute emergency operation with 1 double or 2 single remotes Test switch and LED AC-on indicator light 4.5” 4.5” 2.6” Single Carton Weight: 7.5 lbs. Master Carton Quantity: 4 each 4.25” 10” 4.5” 4.25” 7” 0.9” 7” 0.9” 425 CEW Wet Location LED Emergency Exit Sign FEATURES • • EXIT SIGNS • • • • • • Exit sign for wet location or light industrial environments UV stable thermoplastic grey housing with polycarbonate lens Long life LED lamps provide bright, even illumination Single face end, wall or ceiling mount Double face end or ceiling mount Dual-voltage 120 or 277V AC input Long-life Nickel Cadmium battery with fully automatic charger UL 924 Wet Location Listed ORDERING INFORMATION CATALOG NUMBER CEWSRE DESCRIPTION Thermoplatic, Wet Location Exit, Single-Face, Red Letters, Emergency CEWDRE Thermoplatic, Wet Location Exit, Double-Face, Red Letters, Emergency CEWSGE Thermoplatic, Wet Location Exit, Single-Face, Green Letters, Emergency CEWDGE Thermoplatic, Wet Location Exit, Double-Face, Green Letters, Emergency 12.6” ELECTRONICS • • 4.4” 90 minute emergency operation Test switch and LED AC-on indicator light 5.5” 9.3” 8.5” 12.5” 2.5” Single Carton Weight: 4.3 lbs. Master Carton Quantity: 6 each 426 CWC Wet Location Combination Exit/Emergency Light FEATURES LED based exit/emergency light for wall, ceiling or end mounting Includes Self-Test/Self-Diagnostics Housing made of 5VA flame retardant polycarbonate in white finish Exit face-plate and lamp-head shield made from high impact, UV stable polycarbonate Fully adjustable LED lamp-heads at 3.6W each Long life Nickel Cadmium Battery Temperature Range: 0°C to 50°C, CT Option: -20°C to 50°C UL924 Wet Location Listed EXIT SIGNS • • • • • • • • ORDERING INFORMATION CATALOG NUMBER CWC1RW DESCRIPTION White Housing, Single Face, Red Letters CWC2RW White Housing, Double Face, Red Letters CWC1GW White Housing, Single Face, Green Letters CWC2GW White Housing, Double Face, Green Letters CWC1RW-CT White Housing, Single Face, Red Letters, Cold Temperature Operation CWC2RW-CT White Housing, Double Face, Red Letters, Cold Temperature Operation CWC1GW-CT White Housing, Single Face, Green Letters, Cold Temperature Operation CWC2GW-CT White Housing, Double Face, Green Letters, Cold Temperature Operation ELECTRONICS • • • • • 120/277VAC input AC lockout and Low Voltage disconnect Battery re-charge within 24 hours Self-Test/Self-Diagnostic circuitry Magnetic No Touch Testing 315.0 (12.40’) 150.0 (5.91”) 150.0 (5.91”) 346.7 (13.65”) 323.7 (12.74”) 104.0 (4.09”) Single Carton Weight: 8.0 lbs. Master Carton Quantity: 4 each 427