LM High Capacity Emergency Light EMERGENCY LIGHTING FEATURES • • • • • • • • • • High capacity emergency unit for commercial or light industrial applications White, corrosion-resistant, heavy gauge steel housing in 6 or 12 volt models Fully adjustable, glare free, high-output incandescent lamp heads Maintenance-free battery with fully automatic solid state charger 120/277 60 Hz VAC operation, test switch and LED AC-On indicator light Transformer isolation, surge, transient and low voltage disconnect protection Reverse polarity, short circuit and AC lockout protection Extended remote capacity and time delay retransfer (TDR with Spectron only) Temperature range: 20°C to 30°C (68°F to 86°F), damp: 10°C to 40°C (50°F to 104°F) UL 924 Listed (optional damp location listed) ORDERING INFORMATION ORDERING INFORMATION LM MODEL CAPACITY 2 15 16 24 28 30 33 34 36 40 50 56 66 68 80 100 112 130 10.8 Watt 15 Watt** 16 Watt 24 Watt*** 28 Watt* 30 Watt** 33 Watt 34 Watt* 36 Watt*** 40 Watt 50 Watt** 56 Watt* 66 Watt 68 Watt* 80 Watt 100 Watt** 112 Watt* 130 Watt BATTERY TYPE Blank Lead Calcium N Nickel RATING Blank None D Damp CH Chicago8 Cadmium* *Capacity wattage may change depending upon option OUTPUT VOLTAGE Blank 6 Volt 12V 12 Volt 7 SELF DIAGNOSTICS Blank None I Spectron Self-test/Self- diagnostic Electronics1,3,5 OPTIONS V 3 4 0 A31 A32 24K Voltmeter 3 Lampheads1, 2 4 Lampheads1, 2, 6 0 Lampheads1, 2, 3 Aux 3-conductor cord-120 volt Aux 3-conductor cord-277 volt 220/240 VAC, 60Hz4 1 Not available with LM2 model. Not available with LM15N, LM16 or LM24CH models. 3 NOTE: Spectron models with over 80 watts of capacity require a minimum load of 35 watts for accurate lamp failure indications. 4 Not available with LM15N, LM24CH, LM30N, LM36CH, LM50N, LM100N, LM112D and LM130 models. 5 Not available with Nickel-Cadmium battery models. 6 Not available with LM28D or LM36CH models. 7 Not available with LM2, LM15, LM16, LM28, LM30 and LM33 models 8 Available on LM24 and LM36 models only 9 Not available with LM24CH and LM36CH models 2 *Damp Models Only **Ni-Cad Models Only ***Available wih CH rating option only SRHSW0608 SRHSW0612 SRHSW0618 SRHSW0620 SRHSW0625 SRHSW1208 SRHSW1212 SRHSW1218 SRHSW1225 SRHSW1235 AHDSW1250 OPTIONAL LAMPS 6V, 8W Halogen, plastic lamp head 6V, 12W Halogen, plastic lamp head 6V, 18W Incandescent, plastic lamp head 6V, 20W Halogen, plastic lamp head 6V, 25W Incandescent, plastic lamp head 12V, 8W Halogen, plastic lamp head 12V, 12W Halogen, plastic lamp head 12V, 18W Incandescent, plastic lamp head 12V, 25W Incandescent, plastic lamp head 12V, 35W Incandescent, plastic lamp head 12V, 50W Halogen, metal lamp head To order metal lamp heads, replace SRH with AHD. 50W is available with metal heads only. To order two optional, non-standard lamps on the fixture, suffix catalog number. Example: LM100-SRHSW0612. F E ACCESSORIES MODEL DESCRIPTION 40G Wire guard (Top mounted heads only) Matching Remote Fixtures SRHSW Single matching remote head — white* C SRHDW Twin matching remote head — white* B D *Supplied with round mounting plate. Specify voltage and wattage when ordering. Example: SRHDW1212. See “Remote Heads and Fixtures” section for available lamps. A ENCLOSURE STYLE A B C D E F 20 gauge steel 18 gauge steel 3⅞" 9.8 cm 4¾" 12.1 cm 5¾" 14.6 cm 7¾" 19.7 cm 11½" 29.3 cm 13½" 34.3 cm 13½" 34.3 cm 15¾" 40.0 cm 15¾" 40.0 cm 18" 45.7 cm 25" 63.5 27¼" 69.2 cm LM High Capacity Emergency Light SPECIFICATIONS Standard Models* ENCLOSURE STYLE OUTPUT VOLTS OUTPUT WATTS 1.5 HOURS 2 HOURS 3 HOURS 4 HOURS STANDARD REMOTE LAMP CAPABILITY LM2 1 6 10.8 -- -- -- 5.4W No LM16 1 6 16 -- -- -- 7.2W No LM33 1 6 33 25 17 13 7.2W Yes LM40 1 6 40 31 21 16 7.2W Yes LM66 2 6 66 51 35 27 7.2W Yes LM80 2 6 80 62 43 33 7.2W Yes LM130 2 6 130 101 70 54 7.2W Yes LM40-12V 1 12 40 31 21 16 7.2W Yes LM66-12V 2 12 66 51 35 27 7.2W Yes LM80-12V 2 12 80 62 43 33 7.2W Yes LM130-12V 2 12 130 101 70 54 7.2W Yes *Meets New York City Requirements Nickel-Cadium Models ELECTRICAL CATALOG NUMBERS ENCLOSURE STYLE OUTPUT VOLTS OUTPUT WATTS 1.5 HOURS 2 HOURS 3 HOURS 4 HOURS STANDARD REMOTE LAMP CAPABILITY LM15N 1 6 14.4 -- -- -- 7.2W No LM30N 1 6 30 25 17 13 7.2W Yes LM50N 1 6 50 42 29 22 7.2W Yes LM50N-12V 2 12 50 42 29 22 7.2W Yes LM100N-12V 2 12 100 85 59 46 7.2W Yes Damp Location Models ELECTRICAL CATALOG NUMBERS ENCLOSURE STYLE OUTPUT VOLTS OUTPUT WATTS 1.5 HOURS 2 HOURS 3 HOURS 4 HOURS STANDARD REMOTE LAMP CAPABILITY LM28D 1 6 28 21 15 11 7.2W Yes LM34D 1 6 34 26 18 14 7.2W Yes LM56D 2 6 56 43 30 23 7.2W Yes LM68D 2 6 68 53 35 28 7.2W Yes LM112D 2 6 112 87 60 47 7.2W Yes LM34D-12V 1 12 34 26 18 14 7.2W Yes LM56D-12V 2 12 56 43 30 23 7.2W Yes LM68D-12V 2 12 68 53 36 28 7.2W Yes LM112D-12V 2 12 112 87 60 47 7.2W Yes SPECIFICATIONS All Metal City of Chicago Models* ELECTRICAL CATALOG NUMBERS ENCLOSURE STYLE OUTPUT VOLTS 2 HOURS STANDARD REMOTE LAMP CAPABILITY LM24CH 1 6 24 12W No LM36CH 1 6 36 12W Yes LM36CH-12V 1 12 36 12W Yes *2000 Chicago Building Code compliant EMERGENCY LIGHTING ELECTRICAL CATALOG NUMBERS