High Capacity Emergency Light - Dual-Lite

advertisement
LM
High Capacity Emergency Light
EMERGENCY LIGHTING
FEATURES
•
•
•
•
•
•
•
•
•
•
High capacity emergency unit for commercial or light industrial applications
White, corrosion-resistant, heavy gauge steel housing in 6 or 12 volt models
Fully adjustable, glare free, high-output incandescent lamp heads
Maintenance-free battery with fully automatic solid state charger
120/277 60 Hz VAC operation, test switch and LED AC-On indicator light
Transformer isolation, surge, transient and low voltage disconnect protection
Reverse polarity, short circuit and AC lockout protection
Extended remote capacity and time delay retransfer (TDR with Spectron only)
Temperature range: 20°C to 30°C (68°F to 86°F), damp: 10°C to 40°C (50°F to 104°F)
UL 924 Listed (optional damp location listed)
ORDERING INFORMATION
ORDERING INFORMATION
LM
MODEL
CAPACITY
2
15
16
24
28
30
33
34
36
40
50
56
66
68
80
100
112
130
10.8 Watt
15 Watt**
16 Watt
24 Watt***
28 Watt*
30 Watt**
33 Watt
34 Watt*
36 Watt***
40 Watt
50 Watt**
56 Watt*
66 Watt
68 Watt*
80 Watt
100 Watt**
112 Watt*
130 Watt
BATTERY TYPE
Blank Lead Calcium
N Nickel
RATING
Blank None
D Damp
CH Chicago8
Cadmium*
*Capacity wattage may
change depending upon
option
OUTPUT VOLTAGE
Blank 6 Volt
12V 12 Volt 7
SELF DIAGNOSTICS
Blank None
I Spectron Self-test/Self-
diagnostic Electronics1,3,5
OPTIONS
V
3
4
0
A31
A32
24K
Voltmeter
3 Lampheads1, 2
4 Lampheads1, 2, 6
0 Lampheads1, 2, 3
Aux 3-conductor cord-120 volt
Aux 3-conductor cord-277 volt
220/240 VAC, 60Hz4
1
Not available with LM2 model.
Not available with LM15N, LM16 or LM24CH models.
3
NOTE: Spectron models with over 80 watts of capacity require a
minimum load of 35 watts for accurate lamp failure indications.
4
Not available with LM15N, LM24CH, LM30N, LM36CH, LM50N,
LM100N, LM112D and LM130 models.
5
Not available with Nickel-Cadmium battery models.
6
Not available with LM28D or LM36CH models.
7
Not available with LM2, LM15, LM16, LM28, LM30 and LM33 models
8
Available on LM24 and LM36 models only
9
Not available with LM24CH and LM36CH models
2
*Damp Models Only
**Ni-Cad Models Only
***Available wih CH
rating option only
SRHSW0608
SRHSW0612
SRHSW0618
SRHSW0620
SRHSW0625
SRHSW1208
SRHSW1212
SRHSW1218
SRHSW1225
SRHSW1235
AHDSW1250
OPTIONAL LAMPS
6V, 8W Halogen, plastic lamp head
6V, 12W Halogen, plastic lamp head
6V, 18W Incandescent, plastic lamp head
6V, 20W Halogen, plastic lamp head
6V, 25W Incandescent, plastic lamp head
12V, 8W Halogen, plastic lamp head
12V, 12W Halogen, plastic lamp head
12V, 18W Incandescent, plastic lamp head
12V, 25W Incandescent, plastic lamp head
12V, 35W Incandescent, plastic lamp head
12V, 50W Halogen, metal lamp head
To order metal lamp heads, replace SRH with AHD.
50W is available with metal heads only.
To order two optional, non-standard lamps on the fixture, suffix
catalog number.
Example: LM100-SRHSW0612.
F
E
ACCESSORIES
MODEL DESCRIPTION
40G Wire guard (Top mounted heads only)
Matching Remote Fixtures
SRHSW Single matching remote head — white*
C
SRHDW Twin matching remote head — white*
B
D
*Supplied with round mounting plate. Specify voltage and wattage when ordering.
Example: SRHDW1212. See “Remote Heads and Fixtures” section for available lamps.
A
ENCLOSURE
STYLE
A
B
C
D
E
F
20 gauge
steel
18 gauge
steel
3⅞"
9.8 cm
4¾"
12.1 cm
5¾"
14.6 cm
7¾"
19.7 cm
11½"
29.3 cm
13½"
34.3 cm
13½"
34.3 cm
15¾"
40.0 cm
15¾"
40.0 cm
18"
45.7 cm
25"
63.5
27¼"
69.2 cm
LM
High Capacity Emergency Light
SPECIFICATIONS
Standard Models*
ENCLOSURE
STYLE
OUTPUT
VOLTS
OUTPUT WATTS
1.5 HOURS
2 HOURS
3 HOURS
4 HOURS
STANDARD
REMOTE
LAMP
CAPABILITY
LM2
1
6
10.8
--
--
--
5.4W
No
LM16
1
6
16
--
--
--
7.2W
No
LM33
1
6
33
25
17
13
7.2W
Yes
LM40
1
6
40
31
21
16
7.2W
Yes
LM66
2
6
66
51
35
27
7.2W
Yes
LM80
2
6
80
62
43
33
7.2W
Yes
LM130
2
6
130
101
70
54
7.2W
Yes
LM40-12V
1
12
40
31
21
16
7.2W
Yes
LM66-12V
2
12
66
51
35
27
7.2W
Yes
LM80-12V
2
12
80
62
43
33
7.2W
Yes
LM130-12V
2
12
130
101
70
54
7.2W
Yes
*Meets New York City Requirements
Nickel-Cadium Models
ELECTRICAL
CATALOG
NUMBERS
ENCLOSURE
STYLE
OUTPUT
VOLTS
OUTPUT WATTS
1.5 HOURS
2 HOURS
3 HOURS
4 HOURS
STANDARD
REMOTE
LAMP
CAPABILITY
LM15N
1
6
14.4
--
--
--
7.2W
No
LM30N
1
6
30
25
17
13
7.2W
Yes
LM50N
1
6
50
42
29
22
7.2W
Yes
LM50N-12V
2
12
50
42
29
22
7.2W
Yes
LM100N-12V
2
12
100
85
59
46
7.2W
Yes
Damp Location Models
ELECTRICAL
CATALOG
NUMBERS
ENCLOSURE
STYLE
OUTPUT
VOLTS
OUTPUT WATTS
1.5 HOURS
2 HOURS
3 HOURS
4 HOURS
STANDARD
REMOTE
LAMP
CAPABILITY
LM28D
1
6
28
21
15
11
7.2W
Yes
LM34D
1
6
34
26
18
14
7.2W
Yes
LM56D
2
6
56
43
30
23
7.2W
Yes
LM68D
2
6
68
53
35
28
7.2W
Yes
LM112D
2
6
112
87
60
47
7.2W
Yes
LM34D-12V
1
12
34
26
18
14
7.2W
Yes
LM56D-12V
2
12
56
43
30
23
7.2W
Yes
LM68D-12V
2
12
68
53
36
28
7.2W
Yes
LM112D-12V
2
12
112
87
60
47
7.2W
Yes
SPECIFICATIONS
All Metal City of Chicago Models*
ELECTRICAL
CATALOG
NUMBERS
ENCLOSURE
STYLE
OUTPUT
VOLTS
2 HOURS
STANDARD
REMOTE
LAMP
CAPABILITY
LM24CH
1
6
24
12W
No
LM36CH
1
6
36
12W
Yes
LM36CH-12V
1
12
36
12W
Yes
*2000 Chicago Building Code compliant
EMERGENCY LIGHTING
ELECTRICAL
CATALOG
NUMBERS
Download