EASICHECK™ • Saves time and cost on testing & maintenance EasiCheck™ offers an advanced, versatile and flexible solution to automatic testing, which is easy to use and • Tests fully comply with BS5266 & EN50172 provides a high level of integrity. Each panel can monitor • Easy to use control panel up to 250 luminaires, continuously checking battery • 250 address capacity per panel voltage and charge current. Functionality and duration tests are performed automatically at frequencies that • Stand alone or network up to 63 panels exceed the requirements of the current codes of practice. • Events log and test reports can be printed All faults are displayed on the panel, providing location • Colour graphics software package available text and the nature of the fault, to aid maintenance. EasiCheck™ is suitable for all size of projects, but particularly medium to large installations, where panels can be networked or where optional site monitoring or colour graphics software is required, providing central 199 WHERE TO USE EASICHECK™ • • • • Hospitals Universities, schools and colleges Museums Airports • • • • Shopping centres Retail outlets Offices Industrial facilities Emergency Luminaires - Testing Systems PC control. EASICHECK™ 200 SYSTEM OPERATION PANEL • An EasiCheck™ interface module is fitted into all suitable dedicated emergency luminaires and mains luminaires converted for emergency operation • Each module is given a unique address number, using a hand held programmer • Every luminaire is then connected to a 2 core data BUS cable, which is linked back to the control panel. A single panel can accommodate up to 250 luminaires (self contained systems) or 255 luminaires and addressable devices (central power systems) • When switched on, the panel will self learn the number of luminaires connected to it • Text information can be allocated to each system component, including central battery units and changeover devices etc for central power system versions, during commissioning by a Cooper Lighting and Security service engineer • The panel can then be programmed to carry out automatic test sequences according to BS5266 or EN50172. Testing can also be initiated manually. All test data is sent back and stored at the control panel. Additionally, the system carries out continuous real time monitoring of all connected devices • Central battery unit status is constantly monitored on central power systems version. Multiple CBU's can be controlled by a single panel • In the event of a fault, the precise location of the device is displayed at the control panel along with accurate details of the nature of the fault and an alarm is raised • Luminaire status is provided locally via a 2 colour LED built into each fitting (self contained versions) • A printer can be connected, which automatically prints details of any system events as soon as they occur • The system can be enhanced by networking up to 63 panels. Central PC monitoring and a global network printer can also be incorporated. An advanced colour graphics software package is available to provide central and remote system control and monitoring Constructed from flame retardant polycarbonate. 2 line x 40 character LCD display and soft touch 5 button keypad. A single panel can accommodate up to 250 luminaires or interfaces. If a greater number are required, up to 63 panels can be linked using a networking card. Access to panel functions is by means of a secure password. All functions controlled by the keypad, via a series of user friendly menus with context sensitive help information. System and luminaire faults can be viewed without input of password. Panel has printer connection facility and battery back-up. An on-board alarm is fitted, which is activated when faults are identified. Alarm can be muted using keypad. Panel is used to facilitate following functions: - Set up test types and times - Set up testing groups - Initiate manual tests - Display real time current/voltage of single luminaire - Print test results (remote printer) In - addition, LED indicators display the following status: Power on Emergency mode General fault System fault Test in progress Disable luminaire groups Fault indication in luminaire groups 1-16 DIMENSIONS 12 Cable Entry Points L A C B H MUTE BUZZER Emergency Luminaires - Testing Systems 1 2 3 4 SCROLL 5 D H (mm) L (mm) D (mm) A B C 270 332 90 283 242 198 LUMINAIRE INTERFACE Compact module fitted into all emergency luminaires to be connected to the system. Self-contained and slave luminaire versions. Requires allocation of address by hand held programmer, prior to being connected to data BUS cable. Dims: L54xW38xD24mm. HAND HELD PROGRAMMER Used to program address into all interface devices. Simple to use. Sprung probes are held against interface contacts and program button pressed until display confirms successful programming. Display increments address automatically by 1, ready for next interface. Address number can be manually allocated, if required, using “Tens” and “Units” buttons. Can also be used to read back the address of a programmed interface. Dims: L152xW82xD35mm. Luminaire interface 201 PRINTER High speed thermal printer for connection directly to a dedicated panel, or as a network printer using separate interface. Provides print out of system status, event log as faults occur, or test results. Virtually silent operation. Requires adjacent mains power socket outlet for connection of power supply unit. Dims: L155xW100xD75mm. MAINS CHANGEOVER COMBINED MODULE Used to changeover from normal mains to emergency 230V AC supply. EasiCheck™ addressable version of ACM1. Dims: L215xW37xD30mm. Hand held programmer OTHER INTERFACES & DEVICES Emergency Luminaires - Testing Systems There is a comprehensive range of network interfaces and devices for self-contained and central power supply installations that are available to meet project requirements. For information, please contact our Technical Support and Application department. Tel: 01302 303350. LUMINAIRES EasiCheck™ can be integrated into the majority of Menvier and JSB self contained and slave emergency luminaires or exit signs and most Crompton Lighting emergency converted fluorescent luminaires (when powered via a static inverter). See the individual product entries for details of compatibility. Suitable mains luminaires that are intended for use with a static inverter system can usually be fitted with an EasiCheck™ slave interface. For further information please contact our Technical Support and Application department. Tel: 01302 303350. EasiCheck™ printer EASICHECK™ EASICHECK™ TEST PROGRAMMES EasiCheck™ provides automatic testing that conforms and exceeds the current British Standard BS5266 Part 1 (1999) and the European Standard EN50172. Other test regimes can also be programmed as required. BS 5266 TEST REQUIREMENTS EASICHECK TEST SCHEDULE Daily Check for correct operation Continual Monitoring of battery and charger status Monthly Functionality test not exceeding 25% of rated duration Weekly or Monthly (selectable) Test emergency circuit for up to 5 minutes Six Monthly Test of at least 1 hour for a 3 hour rated system Six Monthly Full duration discharge test Three Yearly Full duration discharge test Yearly Full duration discharge test Subsequently After first 3 years, an annual duration discharge test is required 202 Note: The Fire Precautions (Workplace) Regulations 1997 and EN50172 omit the six monthly 1 hour test, replacing it with an annual full duration discharge test after the first year and every year thereafter It is recommended that discharge tests are performed at a time of least risk, such as outside normal working hours, so that following the test the batteries can be re-charged prior to re-occupation. This can be difficult in permanently occupied premises. To overcome this, EasiCheck™ luminaires can be allocated into 1 of up to 16 test groups and the testing of each group staggered. Adjacent luminaires would be allocated to different groups in order to provide full duration emergency lighting coverage at all times. Following a genuine mains failure that has occurred in the previous 24 hours, the next scheduled test is automatically delayed for a further 24 hours, to allow sufficient time for the batteries to recharge. Manual tests are also inhibited for 24 hours following a genuine mains failure or scheduled test. All test results can be downloaded to an optional printer. EasiCheck™ wiring schematic, demonstrating how allocation of test groups can stagger the testing of adjacent luminaires 1 4 3 Emergency Luminaires - Testing Systems 2 2 4 1 1 3 2 3 2 2 1 3 4 SYSTEM DESIGN & INSTALLATION • Determine the number and type of EasiCheck™ compatible emergency luminaires to be used, using the spacing charts at the rear of this catalogue • Specify the luminaires to be complete with EasiCheck™ addressable interface modules • Locate the control panel in a suitable clean, dry environment, such as a maintenance office • Address all luminaires and interface devices as applicable using the hand held programmer • Connect data BUS cable. Cable should be 2 core twisted pair, typically 1.0 - 2.5mm2 depending on volt drop limitations. Contact Technical Support for full details of the required cable specification. Polarity must be maintained throughout. • Circuit configuration for data cable can be a ring, radial or a preferred combination of a ring with multiple radial spurs • Short circuit isolators are incorporated into the panel as standard. Further isolators can be added to the circuit, if required, to minimise loss of communication due to a short circuit and make fault finding easier. Note: Loss of communication does NOT affect the integrity of the emergency luminaire operation • The panel is set to auto learn the devices connected to it. The panel can then be commissioned by Cooper Lighting and Security, using a PC to download address, group, type of luminaire, number of cells, duration, descriptive address text and test times • The panel can be used to adjust test times, initiate manual tests, display luminaire voltage and current and print out event logs or test results 203 EasiCheck™ typical schematic diagram Optional P.C. Interface Optional Printer Optional Isolator Optional Isolator Optional Isolator Optional Isolator Optional Isolator Optional Printer Interface Optional EasiCheck™ Printer (can also be directly connected to panel) EASICHECK™ Emergency Luminaires - Testing Systems Optional P.C. EASICHECK™ ENHANCED OPTIONS EasiCheck™ can be used as a stand alone system or can be networked, with up to 63 panels being linked. The management of larger installations with multiple panels can be simplified by interfacing the system with a PC based monitoring or graphical control system. Cooper Lighting and Security offer two software systems for use with EasiCheck™. • Site Monitoring Software - 204 - Simple windows based, text driven package Monitors the status of all panels and luminaires All system events and tests are listed as they happen Identifies the address panel/luminaire and location where a fault has occurred Tests can be started or stopped Panels can be reset following clearing of faults Alarm buzzer can be muted - Comprehensive report menu Example of site monitoring software • Colour Graphics - Advanced windows based, graphics package Site plans can be imported Monitors the status of all panels and luminaires All system events and tests are listed as they happen Identifies the address panel/luminaire and location where a fault has occurred Offers full PC control of panel functionality Status, testing and faults can be displayed graphically on site plans Reports can be easily created and printed Emergency Luminaires - Testing Systems Example of colour graphic software CATALOGUE NUMBERS Description Cat. No. Control panel - self contained systems EC1001 Control panel - central power systems EC1002 Interface module - self contained luminaires EC110 Interface module - slave luminaires EC125 Addressable mains changeover relay EC140 Network card (fitted inside control panel) EC150/151 Hand held programmer EC160 Printer EC170 Example of colour graphic software