Bihar Veterinary College, Patna List of equipments along with specifications and quantity as per VCI norms Sl. No. Name of Articles 1 Refrigerator Specifications Vertical type, 310 litre cap., double door, Frost free with power cut evercool and new smart inverter compressor, with automatic voltage stabilizer 2 Quartz Double distillation unit (Vertical) - Borosil make Output cap.- 1.5 litre/hr 230-250 volt single phase 3 kw 3 Electronic balance Single pan, Capacity: (1) 1mg-100g (2) 50 g – 5000 g 4 Muffle furnace 5 6 7 8 Suction Pump Digestion set Micro Kjeldhal apparatus (Manual) Soxhlet apparatus set Inner dimension: 18"X9"X9" Outer dimension: 28"X20"X20" Outside Body made of G.I. Sheet powder coated Inner muffle of Ceramic with high grade ceramic instillation Door insulation of HFK briks Heating element are made from kanthal A1 Wire A Uniform distribution through all 4 sides with kentahl wire Max. Working temp upto 1160 C Equipped with digital temp. Controller cum indicator fitted on top side of the unit with indicating lamps & switches A special type of thermocouple fuse for safety to avoid over heating Power supply 230 Volts, 50 H2 Digital Timer Solid state fuses for extra safety PID Controller with printer interface Max. Vacuum: 650mmHg Max. Flow Rate: 20L/min (100V,110V/60Hz), 17L/min (220V/50Hz) Motor Rotation: 1700 RPM (110V,110V/60Hz), 1450RPM (220V/50Hz) Horse Power: 1/8 HP Pole: 4P Gross Wt: 11.24lbs/5.1kg Port Thread: 5/16" Noise Level: ~50dB Complete electrical setup with auto cut thermostat Std. glass make with complete accessories Borosil glass make with oilflask, condenser, soxhlet with complete 1 9 Near Infra Red Spectroscopy (NIRS) 10 Flame photometer 11 Spectronic 20 Weight: 31 lbs/14.06 kg Dimensions: (Height) 13.93 in/35.4cm, (Width) 15.52 in/39.42 cm, (Depth) 14.25 in/36.19 cm. Power Requirements: 120/220 VAC (50-60Hz) Voltage Range: 90 to 260 VAC (50 - 60 Hz). Sample results Storage: 3000 Readings Caliberation Storage: Flash Memory Display: Touch Screen Display Optical Filters: 4 to 10 ( 10 Filters Standard) Serial Computer Interface: RS-232-C and USB Printer: Optional Sample Integration Technique: Rotating cup Filter Band pass: Approximately 10nm Light Source: Long life Tungsten Halogen ETL Mark: UL61010-1 Humidity: 5% RH to 95% RH to 27.7° C noncondensing decreasing linearly to 60% RH at 35° C decreasing linearly to 50% at 40° C. Altitude: Up to 2000 meters Operating Temperature: 10 - 40° C (machine accuracy specification 10° C - 35° C). Storage Temperature: -20° C to +60° C Calibration Storage: Flash memory - 500 CALIBERATIONS Typical Analysis Time: 10 seconds Detector: Thermoelectrically cooled lead sulfide (Pbs) Reference Measurement: Through entire optical system, against ceramic disk Gain Setting: Automatic for reference gain, calibration file controls gain or sample Diagnostics: Diagnostic screens for troubleshooting indoor use only Calibration curve fit routines first order and second order Data displayed in concentration units i.e. ppm & meq Automatic filter selection Auto calibration feature Printer attachment PC connecting compatibility Sample data storage more than 500 results Sensitivity: General Mode: Na:0.5 ppm, K:0.5 ppm, Li:0.5 ppm, Ca:15 ppm Filters: Na & K Supplied (Ca & Li are optional at extra cost) Resolution: 0.1 ppm/meq Display: 20 x 4 Alphanumeric backlit LCD display Flame System: LPG & dry oil free air Detector: Silicon Photodiode Calibration: Upto 5-Point Calibration with curve fitting software Gas Control:Adjustable with knobs Ignition System: Auto Ignition Automiser: Axial flow type Power: 230 V + 10% AC, 50 Hz With computer and complete accessories Bandwidth: 20 nm Wavelength range: 340 to 950 nm Wavelength accuracy :±2.5 nm near 525 nm Photometric range: Transmittance: 0 to 100.0% T 2 12 Bomb Calorimeter 13 Gas liquid Chromatography unit 14 Fluorescent microscope Absorbance: 0 to 1.95 A Concentration: 0 to 1999 C Detector: Solid-state silicon Output : 0 to 0.1 VDC; RS-232 Stray light : <0.5%T when appropriate stray light filter is used Source lamp: Tungsten Display : 3-1/3-digit LED With power backup stabilizer Automatic Adiabatic type Gallenkamp 301 series With computer and complete accessories Automatic power stabilizer NUCON 5700 Gas Chromatograph make With Glass Lined Injector, Quartz Jet TCD & FID detector and Glass Column, Methaniser, Head Space Attachment and Manual / Auto Gas Sampling Valve With all accessories and power backup Frame : Rigid and vibrations free frame Illuminator : Built-in-Koehler illumination for transmitted light 12V100W halogen bulb (pre cantered)with motion sensor detects when an operator leaves and automatically turns off the light for long life of bulbs, light preset switch, built in filters Observation tube : Wide field trinocular observation head with field no. 22-25 mm Eyepieces : Wide field eyepieces with field No. 22-25 mm Stage : Rectangular Mechanical Stage, Ceramic-coated coaxial stage Focus : Vertical stage movement 25mm stage stroke with coarse adjustment stopper. Torque adjustment for coarse adjustment knobs. Stage mounting position variable, high sensitive fine focusing knob with minimum adjustment graduation should be1µm. Objectives : Plan Achromat Objectives 4X/0.1 Fluorescence/Semi Apochromat Phase Contrast Objectives 10X/0.3 Fluorescence /Semi Apochromat objective 20X/0.5, (spring) Fluorescence /Universal Plan Semi Apochromat Phase Contrast Objective 40X/0.75, (spring) Universal Plan Super Apochromat Objective 60X/1.35, (spring, oil) Universal Plan Super Apochromat Objective 100X/1.4, (spring, oil) Fluorescence Unit : Fluorescence with alignment free 130W mercury/LED illumination .Fluorescence axis should have six to eight cube filter turret with Zero Pixel Shift technology. Single narrow band Filters for UV, Blue & Green range excitation and one triple band filter for UV/Blue/Green excitation Cooled Digital Monochrome Camera : Monochrome camera, 1.4 or more Mega pixel for High Resolution Images, Progressive scan interline CCD, Pixel size 6.45um x 6.45um,1280 - 1392 x 1020 1040 pixels,10fps frame rate, Mono, 12bit, includes camera head,1394 Fire wire digital interface, power supply. High-Speed Readout < Previewing & focusing in real time 10fps full resolution@12bits(165fps maximum with binning and ROI functions), Tight synchronization with flash lamps automated filters, shutter & microscope stages. Linear Full Well 18,000e-(22,000e-with 2x2 binning), Dark current 1.5e /p/s .Minimizing thermal noise during low light, long exposure imaging, 2/3 inch optical format. 2/3 inch C mount adapter. System should be capable of handling bright field and fluorescence object Magnification changer: Having option of 1X, 1.25X, 1.6X and 2X. 3 15 Serologic water bath 16 pH meter digital 17 Hot air oven 18 Incubator 19 Micropipette 20 ELISA reader Double walled construction, Inner made of SS 304Q mirror finish Exterior made of GI sheets/Stainless Steel, Heating is by specially designed water heaters/, Temperature controlled by thermostat Temperature range: 37C - 60C, Control Accuracy: +_2C Bath size 18"X10"X6" Power supply 230 V .A.C 50 HZ Single phase pH Range :0-14pH Resolution : 0.01 pH Temperature Range : 0.0 to 100ºC (Manual Compensation) Display : 31/2 Digit LED Display Power Supply : 230VAC ±10%, 50 Hz Calibration check facility & Calibration Error indication Ovens must be triple walled, Inner chamber made of either M.S. or S.S.304, Gap between the two walled should be filled with ceramic insulation to avoid heat of loses with insulation of 150 mm Heating element are made of special type air heater of S.S. ‘U’ Type. Should provide with three heating elements on three sides of the equipment for uniform temperature on all shelves. Should be provided with air circulating fan. Should provide with a variable microprocessor based digital temperature controller with digital display and thermometer should be provided separate. Should have a minimum chamber size of (L*B*H) 24”x24”x36” with 2 stainless steel trays with holes. Should provide with air ventilations. Should be operated on 230V, 50Hz single phase AC supply and having temperature ranging between 50-200ºC Should be operated on 230V,50Hz single phase AC supply, and having temperature ranging from ambient to 60ºC Should be double walled with stainless steel inner chamber having a minimum of two inner stainless steel shelves with holes and powder coated outer surface. Inner chamber should be fabricated with ribs for adjusting shelves to convenient height. Should have a minimum of chamber size of (L*B*H) of 450*450*450mm. Should be provided with three side heating elements. Should have air circulating fan (Which can be turn ON/OFF on demand) for uniform temperature on all shelves. Should have double door with acrylic transparent door. Should provide with a microprocessor based digital temperature controller with digital display. Should have synthetic rubber gasket at the door. Variable volume 2-20 ul (Inaccuracy(µL) ±0,20 & Imprecision (µL) 0,08), 550ul(Inaccuracy(µL) ±0,30 & Imprecision (µL) 0,15), 10-100ul (Inaccuracy(µL) ±0,80 & Imprecision (µL) 020) Should have 96 wells and reading capability of 1 to 96 wells individually. Should have a linear measurement range of 0 to 3.000 Abs. Should have wavelength range from 400 to 750nm. Should have a photometric accuracy of ±3% or better. Should have a resolution of 0.001Abs. Should have variable speed plate shaking capability. Should have easy access 8 position filter wheel Machine should be supplied with 4 standard filters. Should have automatic filter selection. Should have automatic calibration before each reading. 4 21 Thermocycler 22 Gel documentation system Should have at least 6 second reading speed. Should have facility for storage of calibration curves. Capable of doing multi standard tests and controls. Should have different types of blanking facility like air wise and well wise. Should be capable of reading U, V and flat type wells Should be capable of reading 8 or 12 well strip plates. Should use halogen light source and two spare bulbs should be provided. Should have internal thermal printer and 5 rolls of thermal should be supplied alongwith the unit. Should have external printer connectivity option. Should work with input 200 to 240Vac 50 Hz supply. Technical Specifications for Thermal Cycler General Specifications: Gradient thermal cycler with peltier heating and cooling system. Sample block should have 96x 0.2 ml or 96x 0.2 ml well enabled to run fast chemistry. Block should have option of dual block of 2 X 48 X .2 ml and independently control for both blocks or the block should be able to run PCR for six different annealing temperatures in the same run if it has six zones. Maximum ramp rate should be 5˚C/sec and average ramp rate of 3.3˚C/ sec. Temperature control mode should be calculated and block independent. Display: 8 inch LCD display and touch screen Reaction module specification: • Temperature range should be 0-100˚C. • Temperature accuracy of ± 0.2˚Cof programmed target 0-99.0˚C. • Average temperature rate should have 3.3˚C/ sec. • Temperature uniformity should be ± 0.4 ˚C to 5.0˚C well to well with in 10-20 sec of arrival at 90˚C and have 6 thermo electrical modules. • Should have gradient range of 30-100˚C and have dynamic ramping for gradient. • Temperature differential range should be 1-24˚C. • Memory should be 800-1,000 typical programs onboard, unlimited with USB flash drive expansion. • Security features should be password protected folders, optional log in, and secured mode of high regulated environment. • Instant incubation • The system may support PCR volumes ranging from 10-30ul • Automatic options for Step based graphical and text based programming. • The software should have exportable run logs and system error logs. • Input power range should be 400W and frequency 50-60, single phase. • Online 5KVA UPS • Warranty/Guaranty minimum three years with first one year free spare parts replacement options The system should be image fluorescent DNA, RNA, and protein gels, colorimetric gels and blots and colony arrays. • High resolution CCD camera: 1.4 mega pixel resolution with 1,360 x1,024 pixel array. • Data acquisitions: 12 bit and 4,096 gray level and or Pixel size: 7.4µm x 7.4µm. • Light tight cabinet to provide increase sensitivity to minimize background noise. • Motorized control for zoom with numerical feedback and software acquisition preset integrated into an intuitive and easy to use interface along gel alignment templates, aperture & lens with broad range filter. • Gel alignment templates matched to agarose or protein gel tray and ready gel. • Filter for Fluorescent dyes such as EtBr/SYBR Green/SYBR Safe/Texas Red/SYPRO orange, coomassie blue, silver stain. 5 • Filter size having 25X26 cm area. Trans illumination area with White light converter Screen for viewing protein gels or similar features. • Fire wire connectivity with fast data transfer. • Minimum 3 position filter slider with amber filter. • Software for imaging and analyzing 1-D electrophoretic gels, dot blots and colony counts. Software should be able to do: • Quantitate and analyze a variety of data. • Rapid molecular weight determination with choice of multiple regression models. • Band/lane matching analysis with comparative dandogram creation • Background subtraction correction of gradient gels • Accurate concentration analysis using sophisticated volume tools, volume box, volume circle , volume contour, or free hand drawing. • Local background subtraction for individual bands. • Colony counting that discriminates colonies and plaques. • Array tools to analyze and quantitate dot blots, slot blots, and medium density arrays. • Annotation tools to add text and lines. • 3 D viewer for critical analysis of closely spaced bands • Molecular weight determination • Volume overlays • Text and line overlays • Multiple illumination sources for imaging opaque samples • Dynamic range should be more than 3 orders of magnitude. • A Branded work station- desktop computer, 3GB Ram, 160 GB HDD, CD – DVD Combo Drive, with 17” TFT monitor, windows Compatible for running the 1- D soft ware with suitable LaserJet printer. 23 Refrigerated micro centrifuge machine 24 25 Mini submarine gel electrophoresis unit Mini dual vertical electrophoresis unit 26 vortex shaker 27 Orbital Shaker 1. Max RPM/RCF- 17000/27237g with microtube rotor for 1.5 2. Temp. range- -20ºC to +40 ºC with fast cool button 3. Pulse or continuous time control 4. <56DB noice level with imbalance cut off 5. LCD display 6. safety lid lock lid drop protection with CE mark unit includes buffer chamber, safety lid with cables, UV transparent tray and one each of 1.5 thick 8 and 15 well comb unit include buffer chamber, safety lid with cables, two aluminum notch plate, 10 glass plates, 2 10 well 1 mm thick combs, 4 spacers of 1mm thickness and dual gel caster Heavy metal base with rubber feet Choice of continuous and touch mode variable speed control with maximum speed 3000 rpm one micro tube insert A. General : Bench top microprocessor controlled Refrigerated Incubator Shaker B. Temperature Range: Temperature control range from 7°C above ambient to 60°C control accuracy ±0.1°C. Should be able to maintain 37°C during summer months when ambient temperature is 40-45°C. C. Shaking Features: Electronically controlled shaking mechanism provides quiet operation. Brushless motor is preferable to avoid costly maintenance and noise less. Type of shaking: Orbital. But having any additional feature is advantageous. Speed: 30-300 rpm with control accuracy of ±2rpm It should have acceleration/deceleration circuit prevent sudden 6 28 Deep Freezer vertical with 1KVA voltage stabilizer 29 Laminar Flow Work station (Horizontal), with 2 KVA voltage stabilizer starts/stops to eliminate flask closure wetting which would otherwise interfere with oxygen transfer. It should have timer of up to 99.9 Hrs. D. Display Large easy to read display screen clearly indicates speed, running time, alarm condition and temperature character. Display is clearly visible from all angles across the room, and in the dark. E Safety Features: i There should be over temperature protection. ii Preferably there should be a option to mute the audible alarms. iii The system should have RS-232 port for Data Logging. iv The system should have facility to calibrate the temperature and speed via keypad. v Electronic and mechanical components should be enclosed, protected from accidental spills. vi It should have automatic restart after power interruption with non volatile memory. vii It should have open lid cut out switch stop agitation when chamber is open. F. Essential Accessories It should come with Universal Platform having capacity to holds assortment of various size of flask sizes upto 250 ml to 1000 ml. System should be supplied with 250 ml clamps (5 Nos.), 500 ml clamps (05 Nos.), 1000 ml (02 Nos.) (ii) It should be supplied with compatible stabilizer/servo for smooth operation Digital temperature control and LED Door display and systems monitoring and reporting technology. Minimum attainable cabinet temperature: -20°C with an increment of 1oC Capacity: Minimum 350 ltrs Min 3- 4 multiple freezer compartments with individual insulated doors Insulated inner doors Epoxy covered SS metallic external case. Strong, molded, chemically resistant abs interior. Vacuum Insulation Technology Temperature thermostat regulator. Temperature indicator lamp. Audible and visual alarms for high/low temperature, power failure, high/low voltage, overheated condenser with push button alarm reset/stop and adjustable alarm set points Push button with quick freeze indicator. Acclimatized hermetically sealed cfc free compressor Cascade refrigeration Technology. Automatic defrost with electrical water evaporation system. Adjustable shelves. Door lock Internal Voltage stabilizer. Laminar Cabinets Inner Chamber & Outer Chamber made of stainless steel high efficiency particular air filters, to achieve the air purification upto 0.3 Microns in Working area. Working area 4 ft x 2 ft x 2 ft Blower fitted with ¼ HP Motor, with RPM 1200 to 1400. Pre-filters made of high grade nylon Net fixed in S.S. frame for first Stage air purification, through blower system. Closed Inner Chamber fitted with HEPA having very accurate performance rate of air filtration, rated 99.99%, resulting in ceasing all air bore molecule of particle upto 0.3 micron in working Area of Laminar Bench. 7 30 Ligation bath 31 Semi-automatic rotary microtome 32 Animal Mortuary chamber 33 Deep freezer Horizontal 34 Triple distillation apparatus 35 Leica trinocular research microscope along with camera and computer set Working area of Laminar Airflow Cabinets illuminated by fluorescent light ;cabinets operated at 230V. Single Phase 50Hz. AC Supply. Fitted with UV Germicidal lamp for sterilization. Fitted with Acrylic Front Door sliding type Fitted with Manometer for Measurment of HEPA Filters Choking system. Fitted with Cock for Gas Connection. automatic heating or cooling mode selection thermoelectric cell Temp. Range - + 5 ºC to 60 ºC LED display electronic solid temperature controller on site calibration facility block holds 4ml, 1.5 ml non corrosive body Leica RM2245 Section thickness range-0.5 to 100µm Trimming section range-1 to 100 µm Section mode-2 manual modes (conventional full handwheel rotation and rocking mode) -Specimen retraction 5 – 100 µm in 5 µm increments,can be turned off -Vertical specimen stroke -70 mm -Electric coarse feed 300 µm/s and 900 µm/s -Maximum specimen size (L x H x W) 50 x 60 x 40 mm -Specimen orientation horizontal: 8°, vertical: 8° Nominal supply voltages 100/120/230/240 V AC ± 10% -Nominal frequency 50/60 hz -Power draw 70 VA Temperature- up to -20°C -Exterior surface in chemically treated, antirust coated and duly finished with powder coated paint -Temperature controller is mounted on front panel, provided on front top, along with pilot lamp, main switch etc. Supplied complete with trays, cord and plug. -Power supply 220 V, single phase, 50 Hz, Ac supply. Supplied with suitable Voltage Stabilizer. Size-6X6 ft. Temperature Range- -20°C Design-Horizontal Control Panel- Touch Key Pad w/ LED Display Temperature Regulation- Microprocessor Controlled Alarm Type- Audible & Visible Refrigerant- CFC free refrigerant Construction- Double Walled w/ PUF insulation Door- Solid Door Inner Doors- Single and Double Doors w/ Tempered Glass Cabinet Housing- MS w/ Powder Coating (SS optional) Internal Chamber- Stainless Steel (316 / 304) Power Supply-220 - 240 Volts, 50 Hz. Single Phase Output Capacity (Approx.)-2 Litre/hr. -Electrical Power Reqd.- 220/240 V, Single Phase, 3.5 KW Heater -Cooling Water Consumption-65 lit/hr -Quartz distiller, Demountable boiler. Compact design, Dual safety cutout(optional). High purity, low conductivity, Pyrogen free distillate. 4XCE CCD Metallographic Trinocular Microscope with Camera -Three eyepiece tube- Tilting angle: 30° Adjustable range: 55-75mm -Eyepiece- Wide view eyepiece 10X (16mm), 12.5X, 16X, 20X, 10X flat fielding graduation eyepiece (grid value 0.1mm) 8 36 Micro Slide cabinet(5000 slide 37 Semi-automatic rotary microtome 38 Cry- microtome 39 Hemo Cue WBC Diff. System Split Air Condition for tissue preparation room 40 41 Leica trinocular research microscope along with camera and computer set -Objective lens- Flat fielding achromatic objective lens10X, 25X, 40X, 100X (oil). -Photographic device -1. Image adapting lens, high resolution color CCD camera static and dynamic capturing card, image analysis software, EPSON color jet printer 2. Digital camera, specific adapting lens Horizontal Manner Microslide Cabinet - For handling of 75 x 25 mm slides. Made of mild steel sheet. Well designed for its appearance, performance and durability. Powder coated paint outer finish outer finish with smoothly working doors fitted with handle, lock and key. Leica RM2245 -Section thickness range-0.5 to 100µm -Trimming section range-1 to 100 µm -Section mode- 2 manual modes (conventional full hand wheel rotation and rocking mode) -Specimen retraction 5 – 100 µm in 5 µm increments, can be turned off -Vertical specimen stroke -70 mm -Electric coarse feed 300 µm/s and 900 µm/s -Maximum specimen size (L x H x W) 50 x 60 x 40 mm -Specimen orientation horizontal: 8°, vertical: 8° Nominal supply voltages 100/120/230/240 V AC ± 10% -Nominal frequency 50/60 hz -Power draw 70 VA Freestanding cryostat with encapsulated, splash-proof microtome. - Stable, self-contained cryocabinet on casters. - Cryochamber temperature selection from 0 °C to -30 °C, adjustable in 1K increments at ambient temperature of 20 °C. - Cryochamber defrosting- manually or automatically. - Section thickness selection from outside the cryochamber. -Control panel with membrane-protected buttons - Manufactured in compliance with c-CSA-US and CE standards. CFC-free. -Accessories required to be quoted along with the instruments – 4 Specimen discs- 25 mm, 4 Specimen discs- 30 mm, 1 Section waste tray, 2 Storage shelves. Analyzer 4-50 c (39-122 F .Micro cuvettes 15-35C (59-95)Single Pack micro cuvettes must be used within 10 minutes of opening of individual pack. Split air conditioner ,1.5 ton -Auto defrosting -Energy Saving, Quiet operation -Sleeping Model, Remote Control -Recruit sole agent -AC Stabilizer 4XCE CCD Metallographic Trinocular Microscope with Camera -Three eyepiece tube- Tilting angle: 30° Adjustable range: 55-75mm -Eyepiece- Wide view eyepiece 10X (16mm), 12.5X, 16X, 20X, 10X flat fielding graduation eyepiece (grid value 0.1mm) 42 43 -Objective lens- Flat fielding achromatic objective lens10X, 25X, 40X, 100X (oil). -Photographic device –1. Image adapting lens, high resolution colour CCD camera static and dynamic capturing card, image analysis software, EPSON colour jet printer 2. Digital camera, specific adapting lens Material: PP ABS .Packaging & Delivery Packaging Details: 120 pcs/carton Horizontal Manner Micro slide Cabinet –For handling of 75 x 25 mm 9 44 Slide box(100 slide) 45 Micro Slide cabinet(5000 slide) 46 Binocular microscope 47 MABW200 veterinary urine analyzer 48 Automatic tissue processor slides. Made of mild steel sheet. Well designed for its appearance, performance and durability. Powder coated paint outer finish outer finish with smoothly working doors fitted with handle, lock and key. Optical System- UIS2 (Universal Infinity-corrected) optical system Illumination- Built-in transmitted Koehler illuminator 6V30W halogen bulb 100-120V/220-240Vg 0.85/0.45A 50/60Hz Revolving nosepiece- Quadruple positions fixed (Inward tilted) Stage- 188 (W) x 134 (D) mm Condenser- Abbe condenser, with built-in daylight filter,1.25 (when immersed with oil) Aperture iris diaphragm built in. Principle of determination: by ultra-high degree of cold light reflection. Scope of application : 8 item/10 item/ 11 item/ 12 item/14 item3.Product determination GLU/BIL/KET/SG/PH/BLD/PRO/URO/NIT/LEU/VC/CRE/CAL/MAL Test speed: 60 copies of test/hour continuous test of 120/h Programmable 12 stage timing sequence, having 24 hours calibrated disc, Delay action of 24 hours MODEL MLXi PLUS complete with built-in 6V20W halogen light illuminator, Quadruple ball bearing inward nosepiece, focusing by co-axial coarse and fine focusing controls, High resolution Infinity Corrected Plan Achromatic Objectives 4x, 10x, 40x (spring), 100x oil (spring) with an inclined Seidentopf Binocular observation tube rotatable through 360degree fitted with fungus resistant, anti-reflection coated prism, compensating wide field paired eyepiece WF10x (F.N.20) and with right hand co-axial low drive mechanical stage, sub stage Abbe condenser 1.25 N.A with iris diaphragm focusable with rack & pinion and with blue Filter. Plan Infinity Optics, Excellent Field Flatness, F.N.20, Seidentopf Head, hard coated stage with double slide holder, Easily replaceable lamp, Inward facing nosepiece, upper limit stopper for prevent the specimen in high magnification observation, UniversaPower supply ensures constant voltage & International Build Quality. LCD high power laboratory biological microscope offers high quality optics at an affordable price point. The included 9.7" tablet camera offers a touch screen for capturing images and includes advanced software for making measurements and adding annotations as well as capturing images. Objective Lenses: Infinity Corrected DIN Plan Achromat 4x, 10x, 40xR, 100xR (oil immersion) objectives. All microscope objectives are parfocalled, parcentered and color-coded. Quad objective turret is ballbearing mounted for smooth, precise positioning of objectives, features textured rubber knurling for easy grip. Mounted in reverse position to facilitate ease in changing slides. Eyepieces: Widefield High Eyepoint Focusing 10x eyepieces / FN 20mm. Trinocular Siedentopf viewing head with 30° inclined binocular eyepiece with interpupillary adjustment 50mm to 75mm. Vertical trinocular tube for camera integration. Total Magnification: 40x, 100x, 400x, 1000x. Specimen Stage: Large 140mm x 135mm stage (5.5" x 5.25"), with professional quality, built-in, low profile, ball-bearing mounted mechanical specimen holder with low-position coaxial controls, 78mm (x) by 50mm (y) movement with graduations of 0.1mm. 1.25 N.A. Abbe condenser has rack & pinion focusing and iris diaphragm. Focusing: Coaxial coarse and fine focusing controls, coarse has tension 10 adjustment, fine is graduated. Locking position for stage. Illumination: 3.3v, 3W LED with variable rheostat control and on/off switch.110~240V power supply. Tablet Camera: Includes c-mount adapter and 9.7" Android tablet with built-in 5 mega pixel camera. Size & Weight: "7.25" W x 14.5" D x 16" H, 16 lbs. Warranty: 5 Year warranty, excluding bulb, cord and fuse. Tablet camera has 1 year warranty. Tablet Specifications 9.7" tablet for display and capture. 5 mega pixel camera, image capture resolution 2592 x 1944. 2GB internal flash storage. SD/SDHC Card Slot HDMI Out, USB 2.0, USB Mini B, WiFi, Bluetooth enabled Android version 4.2.2 tablet with touch screen. Color camera with 1/2.5" Aptina MT9P001 Sensor. Capture images (.jpg) and video (.3gp) Video frame rate 15fps @ 1280 x 720, 30fps @ 640 x 480 Live measurement Auto exposure/white balance Tablet has 1-year warranty 49 MAGNUS BINOCULAR RESEARCH MICROSCOPE (Olympus) Dimensions: 18 3/4”W x 15 3/4”D x 19”H Weight: 43 pounds DR1417-6G DRvwt Imaging System with 300,000 shutter exposure life expectancy Imaging Media: DOUBLE SPEED Rare Earth green Phosphor Scintillate Plate 14X17 Image size, 12 mega pixel, 65,536 shades of gray, Full Frame Transfer 16 Bit Includes: Power Cord, Computer Imaging System Interconnection Connector Cables X-Ray Generator kW Rating........................................40kW kVp Range........................................40 to 150kVp, 1kV step Time Range......................................0.001 to 10 sec. mA Range........................................10 to 900mA HV Cable..........................................8 meters kVp Accuracy.....................................<(1% + 1kV) mAs Accuracy....................................<(3% + 0.01 mAs) Generator Mounter............................Provided Line Normal Phase..................... 240V AC, 1, 60Hz @ 70 Amps X-Ray Tube Assembly Model / Maker..................................Toshiba Target Angle....................................16 Degrees Focal Spot Size.................................6 / 1.2 mm Max. Tube Voltage............................125kV Max. Anode HU.................................140 kHU (100kJ) X-Ray Collimator Control............................................Manual, 30 sec. timer Field Shape......................................Rectangular Max. Field Size.................................>43 x 43 cm / 100 cm SID Max. kV Shield.................................150 kV Lamp..............................................Quartz Halogen 160 Lux Digital Image Receptor 11 Active Matrix Size..............................14” x 17” (35 x 43 cm) Image Matrix....................................12 Megapixels Image Resolution..............................Exceeds FDA’s Human Radiology Resolution Standard Acquisition Time................................10 - 20 Seconds Dynamic Range.................................16-bit Grayscale, 65,000 Shades of Gray File Format........................................DICOM Tube Stand & Float Top Table SID .................................................Variable 12” - 40” Grid .................................................200 lpi (ratio 10:1) Table Top Size...................................30” x 64” Tabletop Movement............................4 - way Tabletop Stroke (longitudinal)..............12” (5”) Tabletop Stroke (lateral)......................8” (4”) Dimension.........................................32”(H) x 42”(W) x 40”(D) Weight...............................................80kg (176 lb) software for canine, equine, feline, ovine, bovine etc applications. Accessory Instruments-Lead Apron, Lead Divider, Gloves, Goggles, Film badges, Cassettes-intensifying screen (Rare earth) 50 RICHTER OPTICA U2LCD DIGITAL LCD LAB MICROSCOPE The unit should be for dedicated veterinary purposes for canine, feline, bovine etc; compact easily transportable mobile C-ARM unit with 9” Image Intensifier Unit with High Resolution Camera, Dual Flat Panel high resolution monitors of at least 22” or more, image processing software and storage facility.separateTable 51 Digital X‐ray Machine for large and small animal. The equipment should be / have Suitably designed for veterinary use (mainly for small / pet animals) Easy to clean, have good finishing and the material should be rust proof. Provision of mounting bracket for mounting two vaporizers. Supplied with brand new precision Isoflurane vaporizer of premium quality which should be temperature, pressure and flow compensated. Fitted with specific breathing circuits like non re-breathing system, partial re-breathing system and total re-breathing system. Circle system fitted with fresh gas inlet, corrugated breathing tubes, reservoir bag and pressure gauge, unidirectional aspiratory and expiratory valves; pop off valves as safety device and oxygen flush system. Soda lime carbon dioxide gas absorber (capable of absorbing CO2 expired from 2 kg to 100 kg body weight). Scavenging system. Fitted with unbreakable valve dome caps. The CO2 absorber should be efficient in absorption, seal easily and be leak free seal. capable of working with vaporizer out of circle and vaporizer in the circle. Fresh gas outlet for easy use of a non re-breathing system. Oxygen flow meters of measuring capacity up to 4 liter per minute or more Fitted with low oxygen audio alarm. supplied along with Bain circuit. supplied with different sized veterinary specific induction masks having 12 good fitting rubber diaphragms for variable sized small animals 52 C-ARM supplied with good quality cuffed silicon endotracheal tubes of sizes 214 FR along with adaptors of suitable sizes 10 each. supplied with re-breathing bags of different sizes ranging from 0.5 . 1, 2, 3 and 5L 5 each. compatible for working with IPPV. The mobile trolley should have five legs for maximum stability (two with brakes), stainless steel body, one drawer and platform build on the top for mounting vital signs monitor. The machine should have minimum 2 years warranty/ guarantee period and subsequent AMC rates may be quoted. Bain system and attachement tube 3 piece. One set laryngoscope suitable for small animal The equipment should be / have Suitably designed for veterinary use in large animal (mainly Bovine, equine and small ruminants) with inbuilt ventilator Ventilator should be/have -able to work on 110-220V-tidal volume adjustable (with facility for momentary switch to flush up to 15ltrs)-electronically controlled, time cycled, pneumatic powered.-adjustable frequency (minimum range 0-90 BPM)-adjustable control of inspiratory flow-have varying Inspiration /expiration ratio (range 1:1 to 1:4.5) with upgradation facility. Provision of mounting bracket for mounting two vaporizers. Supplied with brand new precision Isoflurane vaporizer (range 0%-5%) of premium quality which should be temperature compensated. Should be supplied with Foal Absorber, two 30 liter bag, one 15 ltr bag, wye piece, and tubing required. Absorber- circuit should have pressure gauze, APL valve (allowing to make the circuit from completely closed to fully open), check valve for insipratory and expiratory flow. The CO2 absorber should be efficient in absorption. Scavenging system. Supplied with 4 set of cuffed/ without cuff endotracheal tubes of 16,18 and 20 size. One set laryngoscope suitable for large animal. 53 Small Animal Anaesthesia Machine Unit must have medical gradenot less than 15” high resolution TFT LCD monitor. Unit should have Standard Parameters in Modular type: ECG, SpO2, NIBP, Resp, 1 Temp Quoted unit must have Parameters in Modular type : 12CH EKG, 4Temp, 3IBP, ICO, BIS Phaseln’s Multi-gas Mainstream (IRMA AX+), Sidestream(ISA AX+, OR+) Respironics”s EtCO2 Mainstream (C5), Siderstream (LiFIo) Unit should have Virtual Screen. Unit should be fully equipped with software for canine, equine, feline, ovine, bovine etc applications. Unit should have 3CH ECG : Full 7 ECG & ST Segment analysis&12CH ECG : Full 12 ECG & ST Segment analysis. Unit should have more than 13 Arrhythmia analysis & Pacemaker detection. Unit should have more than 160 hoursof tabular and graphic trend data save facility. 13 54 Large animal Anaesthesia Machine with ventilator Unit should have facility for Drug Dose Calculation, ECG Recall, Mini Trend, ICO, Color change,NIBP STAT, NIBP VENOUS STAT, OXYCRG, Patient information Entry. Software upgradation must be on-site through SD Card of required memory. Unit must have durable and light Long Li-ion battery operation with more than; Std-1Pac: 2 / Opt – 2 Pack : 4 hours. Unit should have LAN and Wireless LAN Connection. Unit should have HRV, APG Detection, Touch Screen in option. It must have Built in Printer in option. Unit should be provided with the following accessories: 5 lead ECG cable: 1No. ECG electrodes: 50no. NIBP CUFF (As require in veterinary application of different species):2no. Temp. Probe: Rectal & skin. SPO2 Probe: 01no. (The SpO2 probe must be firm & should have tight grip for best result in veterinary.) Ultrasound phacoemulsification Frequency: 28 kHz, piezo driver Control: auto-tuning (50 times/s), linear, pulsed, burst, cool micropulse phacoemulsif Power: 1-100% in steps of 1%, max. deflection 120 IJm Pulse: pulse frequency 0.5-40 Hz, pulse duration 0.25-1800 ms Counter: effective time in 0.1 s (relevant to energy delivered) Memory: 9 surgeons with 3 memory settings each I/A System Continuous irrigation function Pump system: peristaltic, linear control, proportional override Reflux: pump reverse (150 mmHg) Tubing System: single use or autoclavable 250 ml waste-container Memory: 9 surgeons with 2 memory settings each Performance: 0-50 ml/min, vacuum 0-600 mmHg Diathermy Frequency: 500 kHz, pulsed Power: max. 8 Watt at 500 hm HF Capsulotomy Frequency: 500 kHz, pulsed Power: max. 6.2 Watt at 500 hm, 2 ranges, automatic regulation Vitrectomy Speed: 30-1200 cuts/min Drive: electric, push/pull 14 Power requirements Electric: 100-240 VAC, 50-60 Hz, power consumption 200 VA Dimensions & Weight Dimensions: 220 x 241 (plus 50 mm for handle) x 154 mm (IN pole clamp adds 80 m Weight: 5.6 kg Linear pedal: 180 x 250 mm base plate 2.75 kg Standards IEC601-1, EN60601-1, UL 544, CE-Mark (CE-class 2B, protection class I) EMC/RFI: EN 6100-4-1, EN 50011/ EN 55081-1 EN 50082 6-Step magnification system LED lightsource Lux, life, Kelvin 20W LED coaxial illuminator 10x Wide Field Eyepiece (12.5x available) 250mm Objective Lens (200-400mm also available) Apochromatic Objective Lens Integrated Video Camera Adjustable Eyecups Rotatable Maneuvering Handles Counter-balanced pantographic arms design and tension control adjustable Mounting Options: Fixed Floor, Wall, Ceiling, Table, Mobile Floor Integrated Orange and Green Filter Available foot-long extension arm Upgradable Assistant Scope Eirger 45° inclined or 0-180° inclinable binocular head for Dental surgery 12.5x/18mm High Eye-point Wide-Field eyepieces Range of Pupillary distance: 50mm to 70mm Range of the Diopter of Eyepiece: +/- 7D 250mm APO-chromatic objective lens with fine focusing adjustment knob Magnification: 6-step, Total magnification indicator 0.33=2.8x, 0.5=4.2x, 0.8=6.9x, 1.22=10.40x, 2=17X, 3=25.6x Diameter of object field: 8.7mm to 78.3mm Arms: First big arm, 500mm length can be rotated 360°. Second small arm 600mm in length with movement +/-300mm can be rotated +/-150°. Third angled arm can be 3-D movement Height: 1750mm Base size: 610mm X 600mm One 20W LED Illuminator Maximum Object Illumination: 50,000 Lux Min. Built-in Orange filter and Green filter changed by a knob. Power supply: 220V/50Hz or 110V/60Hz Pupillary distance adjustable: 50mm to 70mm The device activates with the push of a button and results are displayed 15 clearly on the easy-to-read LCD screen. micro strain gage technology and a 1.0 mm transducer tip. microprocessor technology produces objective IOP measurements that are less influenced by operator bias than Goldmann tonometry Wireless binocular indirect with all accessories P D Range: 48 - 76mm High Speed Veterinary Dental Air Unit. This all-in-one veterinarian dental cart, performs all necessary procedures from cutting-polishingscaling. Features: 400,000 RPM high speed drill 20,000 RPM low speed handpiece Built in 25K ultrasonic scaler Auto-tune circuitry Air water syringe Includes oil-less compressor H-Frame mobil stand Independent water controls Built in water reservoir Switching power supply Automatic handpiece activators Fiber Optics System with high speed handpiece Table and all accessory instumentscompatible with machine 5 set. Shortwave cum pulse diathermy unit-1000w trolleymodel Major tense (pain reliever)- 4 channel digital Mini tense (pain reliever)- double channel Interferntial therapy unit with stimulator(lcd Ultrasonic stimulator/therapy- micro controlled based (lcd) Infra red combined with uvr with timer Dorsal/Lateral Scissor Base Equine Table Load Rating-2,500 lbs. (1,134 kg) lateral surface area: 46” wide x 84” long (117cm x 213cm) 55 Veterinary Dental Air Unit 56 Physiotherapy instruments 57 Equine surgery Table dorsal surface area: center bed - 18” wide x 84” long (46cm x 213cm) 58 Laparoscope for small and large animals Lower Height -15-1/2” (39cm) Raised Height- 48” (122 cm) 2-way tilt (in either direction) by retraction of one pair of casters. Endovision camera – 3 CCD video camera with PAL/ NTSC color system consisting of o Camera controller o 3 CCD camera head with C mount adapter o BNC video Cable 3 meters o Shielded S- VHS cable – 2 meters o Power cable o Camera coupler CO2 insufflator capable of insufflation upto 20 liters per minute with following accessories Insufflation tube2.5 meters long – 2 Hygiene filter pack Power cable Halogen light source – 250 watt twin lamp with color correction and heat dissipation. 16 59 Milking machine for cow and buffaloes 60 Chaff Cutter HC-801(Him co) 61 Fodder harvester(Harvesting of fodder crops) 62 Trolley ( Double wheel barrow) Telescope – 10 mm, distortion free, universal ocular 0 degrees Telescope – 10 mm, distortion free, universal ocular 30 degrees Telescope – 5 mm, distortion free, universal ocular 0 degrees Telescope – 5, distortion free, universal ocular 30 degrees Fibreoptic light cable – 2.5 meters, fiber bundle diameter >5 mm. - 2 Veress Needle 20mm working length. Trocar sleeve with magnetic ball valve, metal sleeve, straight distal tip.10 mm capacity, 100 mm working ength. Trocar sleeve with magnetic ball valve, metal sleeve, straight distal tip.5 mm capacity, 100 mm working length. Trocar with pyramidal tip, capacity 5 mm,, working length 100 mm Trocar with pyramidal tip, capacity 10 mm,, working length 100 mm Hand Instruments – all swiveling type, doble action jaws, tungsten carbide jaw inserts in scissors, forceps and needle holders, with monopolar connector pin, and luer lock for cleaning. 5 mm curved grasping and dissecting forceps Maryland dissector 5 mm Atraumatic grasping forceps 5mm both jaws opening Modular scissors 5mm, curved both blades opening, Metzenbaum Universal grasping forceps 5mm both jaws opening Hook electrode diameter 5 mm, length >300mm Needle holder with tungsten carbide jaw inserts, 5 mm Micro hook scissors – 3 mm 20 cm rotating with monopolar pin and luer lock. ALAIN-GROUSSEAU Pylorotome, distendable, size 3 mm, length 20 cm Palpation probe with cm markings 2mm, length 20 cm. Monopolar connecting cable . 2 meters long Suction and irrigation tube with stop valves Clip applicator 10 mm length > 300 mm Reducer adapter for 10 mm to 5 mm and 3 mm, 12.5 mm to 5 and 3 mm and 7 mm to 5 mm and 3 mm. 21” high definition flat screen monitor, aspect ratio 16:10, color system PAL/NTSC, with power cable, mains cord, capable of being mounted on stand, OT light arm or wall. Cabling for Video signals from the CCD endovision camera to be transmitted to recording computer and DVD recorder. Separate flexible endoscope for equine, bovine,dogcystoscope, rectoscope, thoracoscope compatible with machine Specification:-for milking of two animals At a time ,trolley milking system with two SS bucket with recirculation oil lubricant vacuum pump 220 L/minute Suitable for 20 to 50 cows Specification:Cut all types grasses & straw *cuts 6to7 tons of green fodder/hr. in 25 minutes *cuts 1 to 1.5 tons of dry grass & hay/hr Specification:Harvesting & windrowing of fodder crops *field capacity-1 acre/hr *engine:- 10.2 hp diesel air reverse *gear:-4 forward& 1 reverse *width &cut:- 4 feet Bearinf-4 nos. *Tyre:-Olympic rubber tyre *Rod and Ring 17 63 64 Power tiller Deep Freezer Horizontal (-70°C) with 1KVA voltage stabilizer Capacity : 383 ltrs 65 Automatic pipette Washer 66 Immuno-electrophoresis apparatus 67 Phase contrast microscope 68 McIntosh Jar 69 Water bath with shaker 70 71 72 73 74 75 Chick Feeder Chick drinker -2 litter capacity Jumbo chick drinker -4 litter capacity (plastic made) Grower drinker 7 litter capacity (plastic made) Jumbo automatic bell drinker Chick & grower feeder – 2, 8, 10 kg Dimensions (w x d x h) : 28 x 61 x 35 inches Environmentally friendly nature R refrigerant Digital controller Built-in internal and external alarm i. ii. iii. iv. v. vi. Shall be made up of PP or HDPE material. Works on siphoning principal. Proper inlet and out let. Shall accommodate 1 ml, 2 ml, 5 ml and 10 ml pipettes. Shall accommodate pipettes of length of more than 35 cm. Shall be supplied with inlet and outlet tubing. Shall consists of pipette jar, basket, washer-rinser Made up of Acrylic material Electrode holder of Acrylic plastic Both electrode buffer chamber of approx 500 ml Power Supply Inverted Microscope with transmitted light LED illumination. The Microscopes should include - Fixed stage plate with left or right hand drive carrying standard inserts for slide or various culture plates, flasks and Petri-dishes etc. - A 4-fold revolving nosepiece with infinity optics, tube lens, phototubes-condenser holder including collector, aperture diaphragm and filter holder. - Trinocular tube with 40-45° viewing angle Slider for Phase Contrast with 4 positions, 1x Bright field and 3x light rings for condenser. Objectives Plan Achromatic of 4x/5x, 10x, 20x and 40x with long working distance for Bright field and Phase contrast applications. For anaerobic culture Digital Temperature range (25 – 150 0 C) Accuracy : ±0.1°C Uniformity : ±0.1°C Shaking Mode – Orbital-Reciprocating Speed (slightly lower at 50 Hz) 20 to 400 rpm, 10 to 200 oscillations/min Display : Digital tachometer Timer: 99 hours and 59 minutes in 1 minute increments, or for continuous operation Motor : Maintenance-free, brushless Heater: 1500 watts Overall, W x D x H: (31.5 x 16.0 x 15.7) in/ (80 x 41 x 40) cm auto cut thermostat and voltage stabilizer 2 kg, 3 kg Capacity 18 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 Layer feeder/drinker Brooder with chick guard Automatic vaccinator Debeaker Wing band/ Leg band Electric Incinerator Chick sexing machine Automatic pan feeding system Nipple drinking system Special Breeder Nipple Vertical Manure removal system Hanging Feeder Laying/nest Fogger Automatic drinker Egg fumigation cabinet Egg carrying trolleys Other poultry equipments Pellet mills Dies & Rolls Horizontal /Vertical feed mixer Feed grinder 5 kg, 7 kg, 8 kg G.I. make Different capacity Good quality Alluminium made Automatic poultry feed plant Condenser for Motor 40/80 Coupling Rubber Clip Heater U type Contact Thermometer Germany Dry & Wet Thermometer Fan blade for setter Fan blade for Hatcher Fan belt A-75 or A-89 Complete Gear Box Gear Wheel box Gunny Ring with pan Gunny Guard (Thal) Hatcher Tray (10 egg capacity) Hatcher Tray (202 egg capacity) Heater U type (Stainless steel) Humidity drop valve Humidity Transparent pipe (Tubka) Indicator bulbs (6 pc set) Different capacity Good quality Two tier good quality Different capacity Different sizes 25000capacity Different capacity Different capacity 19 117 118 119 120 121 122 123 124 125 126 127 128 Kit Kat Fuse 15 Amp. Micro switch for door contact Micro switch for Turning Micro switch for Heater Micro switch for Humidity Solenoid valve Solenoid valve for water & Air cooling Solenoid valve for Humidity Turning time clock complete set Turning time clock motor Complete Thermostat without capsule In-vitro Gas Production Apparatus 129 130 131 Hotplate Magnetic Stirrer Co2 Cylinder Air conditioner (Split) 132 Hp Computer (Desktop) with all-in-one (Printer+Copier+Scanner) i. HFT-glass Syringes (60 piece), grind with specific capillary attachmentwide execution ii. HFT-clips for silicon tube (500 piece) iii. HFT-silicon tube for HFT-glass syringes (25 metre) With adaptor and accessories With regulator, Medium size Capacity TR (Ton Range): 1.5 T ,Star Rating: 3-5, Cooling (kW): 5-5.5 Power Supply (Volt/Phase): 230/Single ,Power Input (Watts): 1500-2000 Air Direction control: Auto, Dehumidification HD Filter: 60, Anti corrosion finish Display: LED/digital, Remote control Operating system: Windows‐7, Processor: 2.8 GHz, 8 MB cache Memory: Memory: 4 GB DDR3 RAM, Memory slots: 2 or more Storage: Internal drive: 4 GB or more Display and graphics: Display: 27” widescreen Full HD LED, Graphics: HD Expansion: Ports: 2 USB 3.0 (front) , 4 USB 2.0 (back),1 headphone,1 microphone Memory card device: 6‐in‐1 memory card reader Input device: Key board and mouse: Wireless keyboard and wireless optical mouse Communications: Network interface: Ethernet LAN Wireless: Wireless LAN Specification of ALL‐IN‐ONE Functions: Print, copy, scan Display: LCD/LED Printer Method: Monochrome laser Print speed black: Normal: 18 ppm or better Print resolution: 600x600 dpi Monthly duty cycle: 8000 pages or better First printout time: 8.5 sec or better Copier: Speed: 18 cpm or better 20 133 Bomb Colorimeter 134 Canon Photocopier Machine Resolution: 600x400 or better Max no. of copies: 90 or better Scanner: Type: flatbed Scan resolution: 600x600 dpi Scan format: pdf, jpeg, tif, gif, BMP, word Scan size: 216 x 297 mm Working Mode Isoperibol, Dynamic, Manual & Time-Controlled External Power Supply: Voltage Rating 100 -240 V AC Input Power Max 120W Measurement frequency 60 / 50 Hz Calorimeter: Rated Voltage 24V DC 5A Input Power Max 100W Fuse 1 x 2.5 AT On-Time Continuous Operation Protection Class III Protection Class acc. To DIN EN 60529 IP 21 Permissible ambient temperature 20 ºC - 25ºC (constant) Permissible humidity 80% System structure Manual Energy Measurement range Max. 40.000 Joule Reproducibility based on analysis of Isoperibol 0.05% RSD 1g benzoic acid NBS 39i Dynamic 0.1% RSD Fundamental standards DIN 519000, ISO 1928, ASTM 240 D Temperature Measuring Resolution 1 / 10.000K Analysis Time : Isoperibol up to 17 mins Dynamic up to 8 mins Manual(isoperibol) up to 17mins Time-Controlled 14 mins Measuring accuracy ±0.1% Corrections Halogen, sulphur, nitrogen, moisture and ash;Possible only with Calwin software Type of Bomb Removable Standard Bomb C 5010 Halogen Resistant Bomb C 5012 O2 filling of decomposition vessel Manual using Oxygen filling station Venting of decomposition vessel Manual Water handling Manual Interfaces 1 x serial (RS232) 1 x parallel (Centronics) System expansion Calwin software Network connection Auxiliary energy Oxygen (Purity 99.95%) Operating Oxygen Pressure 30 bar Cooling medium Chilled water (17ºC and 25ºC) Weight 21 kg Different capacity 21