application • Subtle enclosure curves provide architectural styling to complement any space. • Smooth brightness across the face of the luminaire prevents glare and provides excellent visual comfort. • Directs a controlled amount of light to higher angles to eliminate “cave effect” without creating glare. • Outstanding visual comfort, ideal for modern offices, schools and retail environments. • High CRI source provides excellent color rendering with a CRI of 80. • LEDs are an excellent source for use with controls since frequent switching does not affect the life of the light source. • Grid, Flange or Z-spline/ Modular models available. contruction/finish • One piece die-formed embossed steel housing provides added rigidity, resists damage during shipment/handling. • T-bar grid clips are built into luminaire ends for quick and easy installation, no extra parts required. • End K.O.s for thru wiring or conduit entry in shallow plenums. • Suitable for end to end mounting. • Many luminaire components, such as reflectors, refractors, lenses, sockets, lampholders, and LEDs are made from various types of plastics which can be adversely affected by airborne contaminants. If sulfur based chemicals, petroleum based products, cleaning solutions, or other contaminants are expected in the intended area of use, consult factory for compatibility. 0168-AR electrical • Driver and LED boards are easily accessible from below. LED boards are individually replaceable, if required, via plug-in connectors. • 0-10V dimming is standard. • Available emergency option requires ballast enclosure on top of luminaire. • Five year standard luminaire warranty including LED boards and driver. Emergency driver and batteries have a three year warranty in models so equipped. • High efficiency LEDs have a minimum 50,000 hour rated life (L70). • ETL listed to UL standards, suitable for damp locations. Architectural SofTrace 2x2 LED enclosure • Choice of three enclosures: – Single piece thermo formed acrylic lens with ribbed center diffuser (D) – Three piece acrylic lens with smooth center diffuser (DS). – Three piece acrylic lens with round perforated steel center diffuser (PMW). • Ribbed side diffusers (RIB option) are available for the DS and PMW center diffuser options. Specifier’s Reference Project Type Model No. Comments Example: 2STG24L840-2-D-UNV-DIM 2 – ST Width Ceiling Type 2 – 2' G – Grid F – Flange Z – Z Spline/ Modular Family ST – SofTrace – 2 Lumens1 24L – 2400 nominal delivered lumens, 30L – 3000 nominal delivered lumens 34L – 3400 nominal delivered lumens 38L – 3800 nominal delivered lumens Length 2 – 2' The lumen values stated above are relevant only to the “D” center diffuser option. For lumen values with the other diffusers, check the photometrics tests online for those specific catalog numbers. 2 SDIM may not be available on all products. Consult factory. Accessories FKDP22 – Flange conversion kit 2'x2' FMA22 – 2'x2' “F” mounting frame for NEMA “F” mounting 0168-AR 04/15 DIM – Dimming D – Diffuse (Ribbed) DS – Diffuse (Smooth) PMW – Round Perf. w/white overlay Footnotes: 1 – Center Diffuser Color Temperature 840 – 80 CRI, 4000K 835 – 80 CRI, 3500K – DIM – 0-10V dimming Voltage UNV – Universal Voltage, 120-277 volt 347 Options CM – Canadian Market CC – Custom Color F1 – 3/8" flex, 3 wire 18 gauge F2 – 3/8” flex, 4 wire 18 gauge GLR1 – Fusing, Fast Blow PAF – Housing painted after fabrication RIB – Ribbed side diffusers (only available with DS and PMW center diffusers) SDIM2 – Step dimming EMLED – Integral emergency battery pack (requires ballast enclosure on top of luminaire) 0168-AR SofTrace 2x2 LED dimensions 4 - 3/8" (111 mm) 24" O.C. Grid Tees (610 mm) Luminaire end Access plate location 7/8" dia. K.O.s 7/8" dia. hole 1-1/2" Grid clip Access plate 90 Grid tees (by others) Open with screwdriver and bend to 90º and over 90° 90 7/8" dia. K.O. ceiling configuration 2 ST G 34L840 Ceiling type G = Grid (NEMA G) SIDE SIDE F = Flange (NEMA F) SIDE 4" Max. 1-5/8" Min. 24" (610mm) Z = Modular & “Z” Spline (NEMA F) SIDESIDE SIDE SIDE 4" Max. 1-5/8" Min. 24" 25" (610mm) (635mm) (NEMA Type G) Lay-in acoustical ceilings using exposed grid suspension, with tees for luminaires on 24" x 24" spacing. 4" Max. 1-5/8" Min. 25" 24" (635mm) (610mm) SIDE 4" Max. 1-5/8" Min. 24" 24" (610mm) (610mm) (NEMA Type F) Flange for acoustical ceilings using concealed mechanical suspension. Swing-jack mounting brackets: adjustment 4" max.and 1-5/8" min. Refer to sheet 801-CL for cut-out information. 24" (610mm) (NEMA M/Z) Modular and “Z” Spline using concealed mechanical suspension. Swing-jack mounting brackets: adjustment 4" max. and 1-5/8" min. photometry 2x2 SofTrace LED, 2400 nominal delivered lumens, diffuse Catalog No. 2STG24L840-2-D-UNV-DIM Test No. 32345 S/MH 1.3 Lamp Type LED Lumens/Lamp 2446 Input Watts 28.1 Comparative yearly lighting energy cost per 1000 lumens – $2.76 based on 3000 hrs. and $.08 pwr KWH. The photometric results were obtained in the Philips Day-Brite laboratory which is NVLAP accredited by the National Institute of Standards and Technology. Photometric values based on test performed in compliance with LM-79. 0168-AR 04/15 LER – 87 Candlepower AngleEnd 45 0 5 15 25 35 45 55 65 75 85 Cross 894894894 887891891 847859868 769796818 659697732 532573607 395430460 257288312 129158179 303941 Light Distribution Average Luminance Degrees 0-30 0-40 0-60 0-90 AngleEnd 45°Cross 45 249826942853 55 228624902662 65 202322602456 75 166220302292 85 113014841577 Lumens % Luminaire 693 28.3 112846.2 195279.8 2445100.0 Coefficients of Utilization EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20) pcc80 70 50 pw 705030 705030 5030 RCR 118118118 115115115 111111 0 1109 104100 106102 97 97 93 298 9183 958982 8480 390 8071 887870 7568 482 7061 816960 6759 576 6355 736154 5953 669 5647 685647 5446 765 5242 645142 5041 860 4639 584639 4538 956 4434 554234 4134 1053 4032 524032 3932 0168-AR SofTrace 2x2 LED 2x2 SofTrace LED, 3000 nominal delivered lumens, diffuse Catalog No. 2STG30L840-2-D-UNV-DIM Test No. 32306 S/MH 1.3 Lamp Type LED Lumens/Lamp 2895 Input Watts 32.6 LER – 89 Candlepower AngleEnd 45 0 5 15 25 35 45 55 65 75 85 Cross 105710571057 104910531054 100110161027 909941968 778825866 626679717 465510543 304342369 153189211 354745 Photometric values based on test performed in compliance with LM-79. 2STG34L840-2-D-UNV-DIM Test No. 32305 S/MH 1.3 Lamp Type LED Lumens/Lamp 3449 Input Watts 40.5 LER – 85 Candlepower Light Distribution Average Luminance AngleEnd 45 Cross 0 125912591259 5 124912551256 15 119212091224 25 108111201153 35 9279811032 45 747808855 55 555607647 65 363407440 75 183224252 85 435655 Degrees 0-30 0-40 0-60 0-90 AngleEnd 45°Cross 45 367439734206 55 336536803924 65 298433473621 75 245930143387 85 169622312185 Comparative yearly lighting energy cost per 1000 lumens – $3.29 based on 3000 hrs. and $.08 pwr KWH. The photometric results were obtained in the Philips Day-Brite laboratory which is NVLAP accredited by the National Institute of Standards and Technology. Photometric values based on test performed in compliance with LM-79. 2x2 SofTrace LED, 3800 nominal delivered lumens, diffuse Catalog No. 2STG38L840-2-D-UNV-DIM Test No. 32072 S/MH 1.3 Lamp Type LED Lumens/Lamp 3869 Input Watts 44.8 Comparative yearly lighting energy cost per 1000 lumens – $2.79 based on 3000 hrs. and $.08 pwr KWH. The photometric results were obtained in the Philips Day-Brite laboratory which is NVLAP accredited by the National Institute of Standards and Technology. AngleEnd 45 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Cross 141114111411 139914061409 137513871397 133613561372 128213111340 121312561294 113211851233 103911011159 941 10101068 838908962 732798850 622682729 515569611 406457496 302349387 204252285 117160176 476463 © 2014 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires Lumens % Luminaire 976 28.3 158946.1 275079.8 3448100.0 Coefficients of Utilization EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20) pcc80 70 50 pw 705030 705030 5030 RCR 0 118118118 115115115 111111 1109 104100 106102 97 97 93 298 9183 958982 8480 390 8071 887870 7568 7061 816960 6759 482 6354 736154 5953 576 669 5647 685647 5446 765 5242 645142 4841 860 4639 584639 4538 4234 554234 4134 956 4032 524032 3932 1053 LER – 86 Candlepower Photometric values based on test performed in compliance with LM-79. 0168-AR 04/15 page 3 of 3 AngleEnd 45°Cross 45 308133413528 55 282130923290 65 250028163035 75 205525392829 85 140518611801 Lumens % Luminaire 819 28.3 133446.1 230979.8 2894100.0 EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20) pcc80 70 50 pw 705030 705030 5030 RCR 0 118118118 115115115 111111 1109 104100 106102 97 97 93 298 9183 958982 8480 390 8071 887870 7568 482 7061 816960 6759 576 6354 736154 5953 669 5647 685647 5446 765 5242 645142 4841 860 4639 584639 4538 956 4234 554234 4134 1053 4032 524032 3932 The photometric results were obtained in the Philips Day-Brite laboratory which is NVLAP accredited by the National Institute of Standards and Technology. Catalog No. Average Luminance Degrees 0-30 0-40 0-60 0-90 Coefficients of Utilization Comparative yearly lighting energy cost per 1000 lumens – $2.70 based on 3000 hrs. and $.08 pwr KWH. 2x2 SofTrace LED, 3400 nominal delivered lumens, diffuse Light Distribution Light Distribution Average Luminance Degrees 0-30 0-40 0-60 0-90 AngleEnd 45°Cross 45 393742644522 55 360439494221 65 319235903901 75 262232323652 85 180324212405 Lumens % Luminaire 1094 28.3 178246.1 308579.8 3867100.0 Coefficients of Utilization EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20) pcc80 70 50 pw 705030 705030 5030 RCR 0 118118118 115115115 111111 1109 104100 106102 97 97 93 298 9183 958982 8480 390 8071 887870 7568 482 7061 816960 6759 576 6354 736154 5953 669 5647 685647 5446 765 5242 645142 4841 860 4639 584639 4538 956 4234 554234 4134 1053 4032 524032 3932 Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ 08873 Tel. 855-486-2216 Imported by: Philips Lighting, A division of Philips Electronics Ltd. 281 Hillmount Rd, Markham, ON Canada L6C 2S3 Tel. 800-668-9008